Mini Arms 4" Diameter
|
|
- Shon Watson
- 5 years ago
- Views:
Transcription
1 Operation and Maintenance Manual Mini rms 4" Diameter MONOXIVENT - SOURCE CPTURE SYSTEMS - info@
2 Mini rms Installation of the Monoxivent extractor arm before beginning operation of ceiling, wall, or bench mount arm. The sole purpose of the Monoxivent mini extractor arm is source capture. This is achieved by loosening the knobs on the three polypropylene joints, positioning the arms for the most effective capture and hand tightening each joint until the arm maintains position. It is recommended that positioning of the arm is best achieved by attending each joint individually starting at the top and working towards the bench top. ir flow can be regulated by the manual damper located just above the hood after the first adjustment joint. Exterior cleaning of the extractor arm is an individual preference as this will not hinder the extraction of fumes through the arm. n interior inspection is recommended periodically, especially if the extractor is not removing fumes as previous. complete interior inspection can be performed by disassembly of each adjustable joint, removing each section of the arm, and verifying the arm is clean of debris. t this time each O-ring should be inspected for cracks and tears. info@ 1
3 Mini rms Torx 30 Torx 30 1 Torx 30 Ø 4 Ø /16 Ø 3/16 L R 2 info@ 2
4 Mini rms 3 Model Model Model Model Model Model B C info@ 3
5 Mini rms Model Model Model Model Model Model info@ 4
6 3 1/ / /2 2 1/2 Mini rms Models with two and three joints Ceiling mount with three joints Size (inches) Weight Standard PP ESD TEX B Total length lb MT ES MT ES MT ES MT PP MT PP MT PP MT with two joints MT ES MT ES Wall mount with three joints Size (inches) Weight Standard PP ESD TEX B Total length lb MV ES MV ES MV ES MV PP MV PP MV PP MV with two joints MV ES MV ES Table mount with three joints Size (inches) Weight Standard PP ESD TEX B Total length lb MB ES MB ES MB ES MB PP MB PP MB PP with two joints MB ES MB ES Pressure drop diagram models 2, 3 and 4 inch 8 /8 B Extractors with designation MV always include a wall bracket B B 4 3/16 Model with gas spring MTS* 8 /8 Ø 3/ (4X) 3 /8 Extractors with designation MB always include a mounting plate Static pressure drop (in/wg) Ø 2 3 joints 2 db() Ø 2 2 joints Ø 3 3 joints 6 db() 4 Ø 4 3 joints 6 db() ir flow cfm The static pressure drop is measured in accordance with ISO-standard The noise level is measured in accordance with ISO-standard info@
7 Mini rms 2 & 3 Inch Size Function ir flow 2 inch Soldering 20 l/s 42 cfm Hair dresser 17 l/s 37 cfm 3 inch Laboratory 40 l/s 8 cfm Schools 40 l/s 8 cfm Typical values for Terfu 4 inch Size Function ir flow 4 inch Laboratory l/s cfm Light industry: -Gluing 80 l/s 170 cfm -Solvents 80 l/s 170 cfm -Brazing l/s cfm -Light welding/tig l/s cfm Range at recommended mounting height, Terfu 2-3 inch The following mounting heights and side displacements are recommended for optimization of evacuation. Recommended mounting height H inches MT MT MT MT Recommended side displacement in relation to workplace S inches MT MT MT MT *For ceiling mounting the extractor is recommended to be positioned over the benchtop, taking other interior furnishing in consideration. * * MT 260 MT 2100 MT 1900 MT 160 MT 130 MT 110 MT 2000 MT 100 MT 1300 MT 1000 MT 2000 MT 100 MT 1300 MT 1000 MT 2000 MT 100 MT 1300 T1000 S S 80 inch. 80 inch. H Working radius Maximum radius 80 inch. H inch inch. Range at recommended mounting height, Terfu 4 inch The following mounting heights and side displacements are recommended for optimization of evacuation. Recommended mounting height H inches MT MT MT MT MT MT Recommended side displacement in relation to workplace S inches MT MT MT MT MT MT *For ceiling mounting the extractor is recommended to be positioned over the benchtop, taking other interior furnishing in consideration. MT 260 MT 2100 MT 1900 MT 160 MT 130 MT inch. Working radius Maximum radius MT 260 MT 2100 MT 1900 MT 160 MT 130 MT 110 info@ 6
FTM-TECHNOLOGIES : 78, rue Raymond Poincaré Nanterre FRANCE Tél Fax:
LOCL EXTRCTOR TERFU local extractor with friction joints for worksites where great flexibility is required. TERFU is a local extractor with friction joints designed for use in workplaces where great flexibility
More informationExtraction arm FX100 Original
Bench top extraction systems for all environments. The Nederman bench top systems can be used in every type of environment, from assembly stations, where soldering fumes are extracted, to laboratories,
More informationLOCAL EXTRACTION Pure advantages. The ideal extractor for light industry and laboratory environments.
The ideal extractor for light industry and laboratory environments. With its optimal design, Ø 4 inch Movex ME has a very low pressure drop, which provides many valuable benefits. - Low pressure drop saves
More informationBench Top Extraction Arms
Bench Top Extraction Arms The Nederman BenchTop arms can be used in every type of environment, ranging from assembly stations, where solder fumes are extracted, to laboratories, where protection against
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for applications where small, flexible and easy-touse arms are required. Nederman FX2 arms are made of lightweight anodized aluminium sections, with three adjustable,
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationALSIDENT SYSTEM 50. A small flexible extraction arm
ALSIDENT SYSTEM 50 A small flexible extraction arm Local Exhaust for a cleaner working environment Installation of individual fume extraction systems at the source of the pollutant during the working process
More informationALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm
ALSIDENT SYSTEM 75 Easily positioned all-round fume extraction arm Local Exhaust for a cleaner working environment Installation of individual fume extraction systems at the source of the pollutant during
More informationSYSTEM10. Airflow Alarm
ALSIDENT SYSTEM10 Airflow Alarm Securing optimal suction efficiency Easily and quickly installed even without expertise Installed directly on the suction arm Easily operated Fits all suction arms from
More information15000 TT Series Tube Type
Operation and Maintenance Manual 15000 TT Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Feb. - 2017 Contents 1. Introduction 2. Application 3. Reservations of Producer 4. Technical Data 5. Structure
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationSoldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing
Soldering/Desoldering Convection Rework Fume Extraction Fluid Dispensing www.beasuperproducer.com BVX-100 Benchtop Single User Arm/Plenum System Portable, single user fume extraction system Low noise unit
More informationBenchTop Extraction Arm FX2 100 Original
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationWeller Info No. 2. New in Weller Volume Extraction System WFE2ES
July 2007 www.cooperhandtools.com/weller New in 2007 Weller Volume Extraction System WFE2ES Weller Info No. 2 New for 2007: Weller Volume Fume Extraction System WFE2ES Our testing conclusively proves that
More informationManual Use and Maintenance ALSIDENT SYSTEM 75
Manual Use and Maintenance ALSIDENT SYSTEM 75 Use and maintenance ALSIDENT SYSTEM 75 System 75 is intended for air volumes between 80 and 180 m 3 /hour and available in the following mounting versions:
More informationSYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information
Alsident System100 Aluminium (AL) Product Information System 100 Aluminium (AL) General Information Product Specification Product Description System 100 Aluminium Alsident System airflow between 140-400
More information1 Safety Cabinets. Underbench cabinets The flexible - fits under your fume hood
Underbench cabinets The flexible - fits under your fume hood 2 3 4 5 6 4 5 86 Underbench cabinets Detailed Description - Maximum convenience for you! Fully extractable drawers Comfort and safety when operating.
More informationSYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR
Alsident System 100 Chemical Resistant (CR) Product Information System 100 Chemical Resistant (CR) General Information Product Specification Product Description System 100 Chemical Resistant (CR) Alsident
More informationSYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 PP SYSTEM 100 ALSIDENT SYSTEM 75. Chemical Resistant (CR) Product Information
ALSIDENT SYSTEM 75 Chemical Resistant (CR) Product Information System 75 Chemical Resistant (CR) General Information Product Specification Product Description System 75 Chemical Resistant (CR) Alsident
More informationFume Extraction Planning Guide
Fume Extraction Planning Guide Which System Should I Buy?... 2 BVX-100 Configurations... 3 BVX-200 Configurations... 4 MFX-2200 Configurations... 5 Selecting Control of MFX-2200... 6 Selecting Exhaust
More informationProduct manual Extraction arm KUA
Product manual Extraction arm KUA Table of contents: Page: Technical description...2 Delivery...2 Advantages...2 Technical data...2 Components and operation...2 Handling...2 Hood operation...2 Mounting
More informationExtraction Arms. Capturing fumes at the source
Extraction Arms Capturing fumes at the source Mm-75 Mm-100 EA Ideal for Bench work and Smaller Working Areas The Miniman 75 mm is ideal for all types of smaller dust and fume applications. Totally free
More informationAlsident System 50 Flex
Alsident System 50 Flex Aluminium (AL) Antistatic (AS) Product Information System 50 Flex General Information Product Specification Product Description System 50 Flex Aluminium/Antistatic The System 50
More informationLeading the way for clean air in the new millennium. S o u r c e C a p t u r e
Leading the way for clean air in the new millennium. S o u r c e C a p t u r e Market Driven Product Solutions Driven by technological innovations and responsive customer service, Airflow Systems, Inc.
More informationEXTRACTION ARMS. Capturing fumes at the source
EXTRACTION ARMS Capturing fumes at the source SOURCE CAPTURE At source capture of airborne particles is the most effi cient method of achieving a safe and healthy working environment. With at source capture
More informationACTIVENT System. Specifications. Product code example ACTA
Activent is a ventilation system for supplying and distributing air. The system has been proven to function effectively in both small and large areas and is used in all types of premises ranging from offices
More informationLABORATORY CABINETRY AND SPECIALTIES: FUME HOODS
Laboratory Cabinetry and Specialties: Fume Hoods LABORATORY CABINETRY AND SPECIALTIES: FUME HOODS 217.540.3100 www.stevensind.com Laboratory Cabinetry and Specialties Fume Hoods.2 Laboratory Cabinetry
More informationCBI JET SERIES. Corrosive. Backward. Inclined. Special Design for: ! Research Centers. ! Laboratory Hood Exhaust. ! Industrial Fume Exhaust
CBI JET SERIES Corrosive Backward Inclined Special Design for:! Research Centers! Laboratory Hood Exhaust! Industrial Fume Exhaust! Waste Water Treatment! Roof or Duct Mounted CBI JET Series Characteristics
More informationFume cupboards and extraction devices
Fume cupboards and extraction devices Energy efficiency, maximum ergonomics and a larger internal workspace make working with our new fume cupboards even safer and more convenient. A new design together
More informationDESKTOP CONTAINMENT SYSTEM
AIR TECHNOLOGIES INC. BRATIN LE OF EX CE G CE Solder and Waxing Fumes Conformal Coating Vapors Reflow Oven Exhaust Wave Soldering Exhaust Dedrossing Solvent Vapors Laser Cutting & Marking CELLE 1991-2
More informationMG200 Filter system OPERATING INSTRUCTIONS FOR A BETTER WORKBENCH ENVIRONMENT FILTRONIC
OPERATING INSTRUCTIONS MG00 Filter system FILTRONIC APEX TOOL GROUP AB Hissgatan, Box 84, 31 0 LIDKÖPING Tel: 010-08 10, Fax: 010-01 40 e-mail: office@filtronic.se www.filtronic.se Version 1 FOR A BETTER
More informationProduct manual Extraction arm KUA
Product manual Extraction arm KUA Table of contents: Page: Technical description...2 Delivery...2 Area of use...2 Technical data...2 Components and operation...2 Working radius...3 Pressure loss...3 Mounting
More informationPortable HEPA System
Operation and Maintenance Manual Portable HEPA System Series - PHS MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 PORTABLE HEPA SYSTEM GENERAL INFORMATION SAFETY PRECAUTIONS: Keep all paper work
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com BVX-100 Fume Extraction System 7100-0070_B SYSTEM OVERVIEW BVX-100 System 1. Plenum (the open portion
More informationProduct manual Junior LM-2
Product manual Junior LM-2 Table of contents: Page: Technical description... 2 Delivery... 2 Advantages... 2 Technical data... 2 Construction and function... 2 Handling... 2 Hood operation... 2 Mounting
More informationSpecifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).
Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and
More informationShut-off dampers. Type AKK. For contaminated air PD AKK 1
X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems
More informationARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B
ARM-EVAC 50 Benchtop Plenum/Arm Extractor MANUAL NO. 8881-0980 REV. B TABLE OF CONTENTS Safety. 3 Introduction 4 Specification.. 4 Features. 5 Set-Up. 6 Operation 7 Maintenance.. 7 Troubleshooting.. 8
More information4m. Extension arm. HVU Arm. ASX ATEX arm. HVU Arm
extension Arms 4m. Extension arm HVU Arm HVU Arm ASX ATEX arm 22 Wing arm WING ARM WING arm The classic point extraction arm. The WING-arm construction is more than 40 years old, but with small improvements
More informationVolume Extraction Extraction Units
Volume Extraction Extraction Units WFE 2S WFE 2 Kit 1 WFE 2 Kit 2 WFE 2S small, portable, quiet with electronic speed control, for centralised applications. The Weller WFE 2S extraction unit purifies the
More informationFume Extraction. 150 Fume Extraction
150 Fume Extraction 100 % Air cleaning Zero-Smog The Weller Zero-Smog Systems put an end to air pollution caused by solder - ing, adhesives and laser work. In all of these applications fumes or fine particles
More informationFUME HOOD SELECTION GUIDE
FUME HOOD SELECTION GUIDE FUME HOOD SELECTION GUIDE Laboratory fume hoods are one of the most vital pieces of safety equipment in a working laboratory. Fume hoods are designed to safely exhaust dangerous
More informationFume Arms. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. No internal adjustment
Diversified Air Systems, Inc. Fume Arms No internal adjustment Smooth tubes, low static pressure Air volume damper included Self-locking joints 2 grab handles for arm positioning Hood diverter increases
More informationEXHAUST EXTRACTOR Pure advantage. Exhaust rails for rescue vehicles
Exhaust rails for rescue vehicles MOVEX exhaust fume rails for emergency vehicles are constructed with load-bearing aluminum profiles and integrated guide rail. The exhaust fume rail is equipped with special
More informationThe BVX-100 Fume Extraction System
The BVX-100 Fume Extraction System USER GUIDE FUME REMOVAL SYSTEMS Copyright 2000, All Rights Reserved 7100-0070 Rev. A BVX-100 USER GUIDE System Overview... 2 System Set Up and Operation... 3 Filtration...
More informationFume Arms. AQC source capture equipment. Superior technology generating substantial operating savings. No internal adjustment
AQC source capture equipment Fume Arms No internal adjustment Smooth tubes, low static pressure Air volume damper included Self-locking joints 2 grab handles for arm positioning Hood diverter increases
More informationproduct data sheet FUA (60Hz) FUA-1800/2100/2700/3000/4700
FU (60Hz) FU-1800/2100/2700/3000/4700 The FU is an extraction fan that is specially designed to remove welding and other fumes, dust, oil mist and exhaust gases. The fan is intended and designed for mounting
More informationFume cupboard systems
69 DATA SHEETS Fume cupboard systems Bench-mounted fume cupboard (DS) 10 11 GENERAL INFRMATIN Fundamental safety and performance targets The DELTAguard bench-mounted fume cupboard is designed in such a
More informationAccessories Standard Service Fixture Kits
Standard Service Fixture Kits For mounting on the left or right side of any Protector Premier, XStream, XL, XLE or PVC Hood. Each kit includes one remotely-controlled service fixture with valve and 0.25"
More informationWhy Fume Extraction? Lead-Free Solders Are The Worst
Why Fume Extraction? A healthy work environment is not only safe, but it has been proven to reduce staff turnover and absenteeism, control healthcare costs and increase operator productivity. Lead-Free
More informationExtraction arms for every type of application
1 Extraction arms for every type of application 2 Improved workspaces within arm s reach A workspace free from dust, hazardous particles, fumes and exhaust is good in many ways. It improves the working
More informationThe widest range to provide the optimum tailor made solutions to your fume and gas extraction needs.
FUME XTRACTION ARMS Improving your workspce Chemicl resistnt Antisttic Stndrd FX ARMS The widest rnge to provide the optimum tilor mde solutions to your fume nd gs extrction needs. Avilble in Stndrd, Antisttic
More informationWELDING FUME EXHAUSTERS & ARMS
WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through
More informationTSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.
TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys
More informationFume Extraction & Dust Collection
1.877.632.4118 mepbrothers.com 725 Century St. Winnipeg, MB. R3H 0M2 Fume Extraction & Dust Collection Shaker Dust Collectors Maxiply Economical pocket type dust collector with manual shaker cleaning (95
More informationIN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series
Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to
More informationProducts, systems and solutions for improved workplaces 2009/2010
Products, systems and solutions for improved workplaces 2009/2010 Bringing good conditions to workplaces and the environment For more than 60 years Nederman has developed products and solutions to reduce
More informationIN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series
Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).
More informationCBC-A Air curtain cabinet
ASSEMBLING-& OPERATING MANUAL CBC-A Air curtain cabinet FILTRONIC Hissgatan 2, Box 2284, SE-531 02 LIDKÖPING Tel: +46 510 208 10, Fax: +46 510 201 40 e-mail: office@filtronic.se www.filtronic.se Version
More informationPRODUCT GUIDE. For a better workbench environment!
PRODUCT GUIDE FILTRONIC Box 2284 SE- 531 02 LIDKÖPING Tel. +46 510 208 10 Fax. +46 510 201 40 office@filtronic.se www.filtronic.se For a better workbench environment! Content High airflow systems 3-7 MG-series...
More informationASALAIR FUME CUPBOARD /R WITH HEPA FILTER
ASAL S.R.L. - APPARECCHI SCIENTIFICI ATTREZZATURE LABORATORI Quality System comply with requirements of UNI EN ISO 9001:2008. Certificate TÜV Italia n 50 100 3290 Rev. 04 ASALAIR FUME CUPBOARD 701 701/R
More informationPractical examples of installation in the TD range
Practical examples of installation in the TD range The TD-MIXVENT system offers the most versatile installation range on the market, as a result of its multiple combinations; it can be used in a large
More informationducting systems for ventilation and extraction
The bathroom and WC; a place where we need privacy and comfort. These are areas where odours and humidity can occur. This is the world where Gonal s Technology can help; sometimes seen, sometimes not.
More informationENGINEERED FOR EXCEPTIONAL PERFORMANCE.
ENGINEERED FOR EXCEPTIONAL PERFORMANCE. FIRST AND ONLY MOTORIZED ARM ON THE MARKET The SCA608, 610, and 614 P models feature a linear actuator that moves the arm up and down electronically. This allows
More informationYOUR VEHICLE EXHAUST REMOVAL SOLUTION FOR A HEALTHIER WORK ENVIRONMENT
YOUR VEHICLE EXHAUST REMOVAL SOLUTION FOR A HEALTHIER WORK ENVIRONMENT PLYMOVENT EXHAUST REMOVAL SYSTEMS Designed to protect your people and your facility Exposure to vehicle exhaust emissions can cause
More informationRoomMaster ABR-2. Installation
Installation List of contents General General... 3 Specification... 3 Accessories... 3 Dimensions and weight... 3 Delivery and transport... 4 Disassembling the unit... 4 Positioning the unit... 5 Reduced
More informationOperation Manual for ARM-EVAC 150 Fume Extraction System
Operation Manual for ARM-EVAC 150 Fume Extraction System MANUAL P/N 5050-0593 REV. 11 Nov 2018 This manual applies to: Model Required Power Part Number ARM-EVAC 150 120 VAC 8889-0150-P1 ARM-EVAC 150 230
More informationTubular Centrifugal Fans
Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,
More informationC O L M A N. Air Distribution FLOOR SWIRL DIFFUSERS B SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S FLOOR SWIRL DIFFUSERS B SERIES B SERIES B SERIES FLOOR SWIRL DIFFUSER Application: The B series floor/swirl diffusers are designed
More informationDATA SHEETS. Fume cupboard systems Walk-in fume cupboard (DB)
69 DATA SHEETS Fume cupboard systems Walk-in fume cupboard (DB) 28 29 GENERAL INFRMATIN Fundamental safety and performance targets The walk-in fume cupboard is designed in such a way that hazardous airborne
More informationKVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets
KVR Capture Jet Round Island Hood with Perimeter Jets The KVR Round Island Capture Jet hood with perimeter jets is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat
More informationproduct data sheet fua-1800/2100/2700/3000/4700
FU (60hz) fua1800/2100/2700/3000/4700 The FU is an extraction fan that is specially designed to remove welding and other fumes, dust, oil mist and exhaust gases. The fan is intended and designed for mounting
More informationDIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide
VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Simple to install Cleanable Concealed fastening Available
More informationInstallation Instructions
010A00 011A00 014A00 SMALL ROOFTOP UNITS TWO POSITION OUTDOOR AIR DAMPER 2to15TONS (50/60 Hz) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE... 1 SAFETY CONSIDERATIONS...
More informationProtector. Storage Cabinets, Base Stands & Fume Hood Accessories
Protector Storage Cabinets, Base Stands & Fume Hood Accessories Storage Cabinets & Base Stands Selection Guide Complete your installation of a Labconco fume hood or enclosure with a Labconco base cabinet
More informationDATA PD LS1..., LS2..., LS3... Lift Axle Valves - Pneumatic. P r o d u c t. Function. Technical Features
C o m m e r c i a l V e h i c l e S y s t e m s P r o d u c t DATA PD-503-200 Function Pneumatic Lift Axle Control Valves are used for the semi-automatic or fully automatic control of air suspended lift
More informationISLAND INSTALLATION WALL INSTALLATION
HEIGHT OF HOOD The bottom of the hood should be 30 (76.2 cm) min. to 36 (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (175.3 cm) above
More informationBall-bearing KUA. A superflexible extractor for small and medium sized work places
Ball-bearing KUA A superflexible extractor for small and medium sized work places Copyright. All rights reserved. PLYMOVENT AB Föreningsgatan 37, SE-211 52 Malmö, Sweden Tel: +46 40 30 31 30, Fax: +46
More informationMounting Instruction MiniSKiiP
Mounting Instruction MiniSKiiP Revision: 1.2 Issue date: 2014-11-03 Prepared by: Musamettin Zurnaci Approved by: Markus Pohl Keyword: Mounting Instruction MiniSKiiP 1. Related Documents... 2 2. Surface
More information3:1 MOBILE LUBE PACKAGES (55 gal)
3:1 MOBILE LUBE PACKAGES (55 gal) Dolly-mounted oil dispenser kits with digital metered valve and 3:1 pumps. Available with or without hose reel. The ideal combinations for dispensing oil in any workplace.
More informationT: +44 (0) F: +44 (0) E:
CONTROL UNIT AE s control s offers a good working environment, adapted to all types of facilities. The right choice of control s is energy-saving and provides the lowest possible noise levels. automation
More informationFan Powered Terminal Units FPV, FDV Series Variable Volume Parallel Flow
Recommended Air Volume Ranges CP 101 Unit Size L/s Min.* L/s Max. cfm Min.* cfm Max. 6 31 212 66 450 8 62 378 132 800 10 104 637 221 1350 12 146 991 310 2100 14 207 1416 439 3000 16 268 1888 568 4000 CP
More informationHORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1
HORD Hospital Operating Room Diffusers Date: 06 / 12 Reference # : E-10 1 2 Table of Contents Prior to Installation... 4 Ductwork Layout... 4 Installation of HORD Air Curtain System...5-9 T-Bar Ceiling...5-6
More informationFilter Hood Model CA-S
Model CA-S Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety,
More informationMultifunctional 400ºC/2h and 300ºC/2h roof fans
HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544
More informationC O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S CIRCULAR DIFFUSERS LRS SERIES LRS SERIES CIRCULAR DIFFUSERS L SERIES Application Colman Air Distribution L series circular swirl diffusers
More informationFume Extraction. Solutions and systems for soldering, rework and repair of electronics. worldwide
Fume Extraction Solutions and systems for soldering, rework and repair of electronics worldwide Fume Extraction Systems worldwide As the full solution provider in the electronics industry, PACE has set
More informationLABORATORY FUME HOODS
Fume Hoods Fume Hood Applications Laboratory professionals and students across the country, and all over the world, depend on the safety of our hoods. Your protection is our first concern and the fume
More informationClear Creek Business Center 187,865 Sq. Ft. OFFICE/FLEX/INDUSTRIAL
Clear Creek Business Center 187,865 Sq. Ft. OFFICE/FLEX/INDUSTRIAL 6800-6880 N. Broadway, Denver CO 80221 Lease rates & terms AVAILABLE 6860 6850 3.1 Acre Build-To-Suit Site 6800 8 High-quality buildings
More informationFeatures. Marathon SL TECHNICAL CHARACTERISTICS. Sliding bushes: made of friction free and wear free material.
Features TECHNICAL CHARACTERISTICS Fork with Ø30 mm legs with "Double Air" damping system. Adjustment of the air preload (positive air) on both legs. Adjustment of the rebound damping (negative air) on
More informationFume Extraction. Solutions and systems for soldering, rework and repair of electronics
Fume Extraction Solutions and systems for soldering, rework and repair of electronics Fume Extraction Systems As the full solution provider in the electronics industry, PACE has set the standards for over
More informationUSER MANUAL TMT-PH200 IR PREHEATER.
USER MANUAL TMT-PH200 IR PREHEATER www.thermaltronics.com TABLE OF CONTENTS TMT-PH200 SPECIFICATIONS... 1 INTRODUCTION... 1 SAFETY PRECAUTIONS... 2 CONTROL PANEL... 2 UNPACKING/ASSEMBLY/OPERATION... 3
More informationUser Instruction SUPER-PM ATEX. Note! Before installation and use in application follow the instructions
User Instruction SUPER-PM ATEX Note! Before installation and use in application follow the instructions PLYMOTH-PLYMEX GmbH Zilzkreuz 14 53 604 Bad Honnef Tel.: 02224/98853-0 Fax: 02224/98853-22 e-mail:
More informationHow to Use a Chemical Fume Hood Safely
Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) How to Use a Chemical Fume Hood Safely SafetyNet #: 35 A chemical fume hood is designed to protect the worker from volatile and
More informationUser Manual. Model: FSL300 Dual Port Laser Fume Extractor
User Manual Model: FSL300 Dual Port Laser Fume Extractor WWW.FSLASER.COM 1. Product Overview This high quality fume extractor featuring low noise brushless motor technology is designed for capturing dust
More informationA X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S
A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S Australia s leading fan company PRODUCT OVERVIEW COMMERCIAL INDUSTRIAL POWER & ENERGY MINING FOOD PROCESSING
More informationTECHNICAL INFORMATION
03/2004 648-A 1 WORKING MACHINE WITH SOLVENT: PERCLORETHILENE MACHINE CAPACITY (RATIO 1:20) Lbs 55 60 BASKET Diameter Depth Volume Wash speed without Inverter Extract speed without Inverter Wash speed
More information