Filter Hood Model CA-S

Size: px
Start display at page:

Download "Filter Hood Model CA-S"

Transcription

1 Model CA-S Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety, health, comfort and productivity of kitchen staff. The hood is installed two metres (six feet, six inches) above the floor and overhangs cooking units by approximately 300 mm ( inches). Operation Hot air, smoke and grease vapours rise towards the hood just above. The air flow from cooking surfaces is drawn through the filters to remove grease particles and deposit them in a trough running to a grease cup at one end. Exhaust The quantity of air exhausted by a hood depends upon the type of cooking equipment used. When heated by the cooking surfaces smoke and grease laden air rise towards the exhaust hood. (see the Thermal currents Chart). Construction All stainless steel construction,.09 mm, (8 MSG) thick, type 304, with no. 4 finish on apparent surfaces. Each section of the hood is equipped with mounting tabs. Exhaust Ducts All exhaust ducts are installed according to NFPA 96. Horizontal ducts must be sloped towards the exhaust duct collar to avoid liquid accumulation. Fire Suppression System According to NFPA 96 and the National Building Code, the use of this type of hood requires a fire suppression system to protect the filter bank, the exhaust ducts and cooking equipment. The system is activated by fusable links or thermal detectors located inside the hood. In case of fire, air exhaust is maintained but make-up air supply is interrupted. The filter bank, exhaust ducts and cooking surfaces are sprayed with chemical product. Gas and electricity to the cooking equipment and lighting are interrupted and an alarm rings. HOOD LISTED Manufactured in accordance with NFPA 6

2 Model CA-S PD w 00 DP 80 w 00 x H L PLAN Mounting tabs - Exhaust duct collar 7 - Junction box 0 volts 4 - Grease cup - maximum capacity 500 ml 5 - Stainless steel filters U.L.C. listed 80 - Sealed fluorescent light fixture 80 W - 0//60 8- Sealed incandescent light fixture 00 W - 0//60 SIDE VIEW Weight in Kg. per Metre of Lineal Hood Depth: kg/m: Weight in Pounds per Foot of Lineal Hood Depth: Lbs/ft: SIZE L : H : D: x : w : Total Air Exhaust: SUGGESTED SPECIFICATIONS Size: Length: Depth: Height: installed 000 mm (78 inches) from the floor. Description CADEXAIR, model CA-S- ( ), wall mounted (or island type), supplied with stainless steel baffle filters. The hood is ULC approved and is built according to NFPA 96. Construction: The housing of the hood is made of # 304 stainless steel.09 mm thick (8 MSG) with # 4 finish on apparent surfaces. All welded joints are polished to the original finish. Each section of the hood is equipped with mounting tabs and grease cup. Skirting: The space between the top of the hood and the ceiling is enclosed by stainless steel panels with the same finish as the hood. Lighting: fluorescent light fixtures with two tubes, vapour proof, watts, volts, phase, cycle, 00 mm (48 inches) in length, incandescent light fixtures, vapour proof, watts, volts, phase, cycle, wired to a junction box. Work by Ventilation Contractor: Connect exhaust duct collar, located on the top of the hood, to the exhaust system. All exhaust ductwork must be installed according to NFPA 96 and be sloped towards the hood duct collar to avoid liquid accumulation. Work by Electrical Contractor: Supply and install lighting wiring from control panel to junction box on top of the hood.

3 Model CA-S-PE Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety, health, comfort and productivity of kitchen staff. The hood is installed two metres (six feet, six inches) above the floor and overhangs cooking units by approximately 300 mm ( inches). Operation Hot air, smoke and grease vapours rise towards the hood just above. The air flow from cooking surfaces is drawn through the filters to remove grease particles and deposit them in a trough running to a grease cup at one end. Exhaust The quantity of air exhausted depends upon the type of cooking equipment installed under the hood. When heated by the cooking surfaces, smoke and grease laden air rise towards the exhaust hood. (see the Thermal currents Chart). Make-Up Air A make-up air housing, made of insulated stainless steel is secured to the front of the hood. The replacement air is diffused and directed towards the ceiling with the use of stainless steel grills built into the housing. This low projection feature limits air movement to the zone surrounding the cooking equipment. Construction All stainless steel construction,.09 mm, (8 MSG) thick, type 304, with no. 4 finish on apparent surfaces. Each section of the hood is equipped with mounting tabs. Exhaust Ducts All exhaust ducts are installed according to NFPA 96. Horizontal ducts must be sloped towards the exhaust duct collar to avoid liquid accumulation. Fire Suppression System According to NFPA 96 and the National Building Code, the use of this type of hood requires a fire suppression system to protect the filter bank, the exhaust ducts and cooking equipment. The system is activated by fusable links or thermal detectors located inside the hood. In case of fire, air exhaust is maintained but make-up air supply is interrupted. The filter bank, exhaust ducts and cooking surfaces are sprayed with a chemical product. Gas and electricity to the cooking equipment and lighting are interrupted and an alarm rings. HOOD LISTED Manufactured in accordance with NFPA 6

4 Model CA-S-PE w 00 (00) (00) D P 80 w 00 DP 80 x H " y PLAN - Mounting tabs - Exhaust duct collar 7 - Junction box for lights 0 volts 4 - Grease cup 5 - Stainless steel filters ULC listed 0 - Make-up air duct collar - 50 mm ( inches) high - Insulation - 5 mm ( inch) thick 3 -Integrated stainless steel grill 80 - Sealed fluorescent light fixture 80 W - 0// Sealed incandescent light fixture 00 W - 0//60 0 L ( 000) 7 (50) (300) 0" " SIDE VIEW Weight in Kg. per Metre of Lineal Hood Depth: kg/m: Wight in Pounds per Foot of Lineal Hood Depth: Lbs/ft: SUGGESTED SPECIFICATIONS Size: Length: Depth: Height: installed 000 mm (78 inches) from the floor. CADEXAIR, model CA-S-PE- ( ), wall mounted (or island type), supplied with stainless steel baffle filters. Stainless steel grills are built into the insulated front housing to supply replacement air from the front of the hood. The hood is ULC approved and is built according to NFPA 96. Construction: The housing of the hood is made of # 304 stainless steel.09 mm thick (8 MSG) with # 4 finish on apparent surfaces. All welded joints are polished to the original finish. Each section of the hood is equipped with mounting tabs and grease cup. Skirting: The space between the top of the hood and the ceiling is enclosed by stainless steel panels with the same finish as the hood. Size L : w : D : x : H : y : Total Air Exhaust : Lighting: fluorescent light fixtures with two tubes, vapour proof, watts, volts, phase, cycle, 00 mm (48 inches) in length, incandescent light fixtures, vapour proof, watts, volts, phase, cycle, wired to a junction box. Work by Ventilation Contractor: Connect exhaust duct collar, located on the top of the hood, to the exhaust duct system. All exhaust ductwork must be installed according to NFPA 96 and be sloped towards the hood duct collar to avoid liquid accumulation. Work by Electrical Contractor: Supply and install lighting wiring from control panel to junction box on top of the hood.

5 Air Volume Chart S Exhaust duct collar sizes are based on a velocity of 9 metres per second (700 fpm). Make-up air duct collar sizes are based on a velocity of 5 metres per second (000 fmp). Static pressure at the exhaust duct collar (B) is 30 mm (. inch) of water column or 300 Pa. Static pressure at the make-up air duct collar (C) is 0 mm (0.4 inch) of water column or 00 Pa. A EXHAUST FLOW RATE See Thermal Currents Chart COOKING EXHAUST FLOW RATE EXHAUST FLOW RATE IN EXHAUST FLOW RATE IN GREASE EXTRACTOR EQUIPMENT IN CFM/FT L/s PER METRE m 3 /h PER METRE ADJUSTMENT IN mm Very light (ovens) Light, Electric (counter equipment) Light, Gas (counter equipment) Medium, Electric (restaurants) Medium, Gas (restaurants) Heavy Duty, Electric (hotels, institutions) Heavy Duty, Gas (hotels, institutions) Very Heavy Duty, Electric (charbroiler) Very Heavy Duty, Gas (charbroiler) Exhaust Opening B A Exhaust flow rate x length of extractor Make-up Air Opening Maximum air throw:.5 M (5 ft) Make-up air volume based on 80% of exhaust volume C 4 CFM Opening m 3 /h L/s Opening CFM Opening m 3 /h L/s Opening x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x0 () 400 () 8 x () 576 () 60 () 00 x 50 () 480 () 8 x 3 () 70 () 00 () 00 x 300 () 560 () 8 x 5 () 864 () 40 () 00 x 340 () 640 () 8 x 6 () 008 () 80 () 00 x 400 () 70 () 8 x 8 () 5 () 30 () 00 x 440 () 800 () 8 x 9 () 96 () 360 () 00 x 480 () 880 () 8 x () 440 () 400 () 00 x 50 () 960 () 8 x 3 () 584 () 440 () 00 x 560 () 040 () 8 x 5 () 78 () 480 () 00 x 60 () 0 () 8 x 6 () 87 () 50 () 00 x 650 () 00 () 8 x 7 () 06 () 560 () 00 x 690 () 80 () 8 x 9 () 60 () 600 () 00 x 740 () 360 () 8 x 3 () 304 () 640 () 00 x 780 () 440 () 8 x 3 () 448 () 680 () 00 x 80 () 760 () 8 x 8 () 96 () 360 () 00 x 480 () 800 () 8 x 9 () 368 () 380 () 00 x 500 () 840 () 8 x 0 () 440 () 400 () 00 x 50 () 880 () 8 x () 5 () 40 () 00 x 540 () 90 () 8 x () 584 () 440 () 00 x 560 () 960 () 8 x 3 () 78 () 460 () 00 x 590 () 000 () 8 x 4 () 800 () 480 () 00 x 60 () 040 () 8 x 5 () 87 () 500 () 00 x 630 () 080 () 8 x 5.5 () 944 () 50 () 00 x 650 () 0 () 8 x 6 () 06 () 540 () 00 x 670 () 60 () 8 x 6.5 () 088 () 560 () 00 x 690 () 00 () 8 x 7 () 60 () 580 () 00 x 70 () 40 () 8 x 8 () 3 () 600 () 00 x 740 () 80 () 8 x 9 () 304 (0 60 () 00 x 760 () 30 () 8 x 30 () 376 () 640 () 00 x 780 () 360 () 8 x 3 () 448 () 660 () 00 x 800 () 400 () 8 x 3 () 50 () 680 () 00 x 80 () 440 () 8 x 3.5 () 59 () 700 () 00 x 840 () 480 () 8 x 33 () 664 () 70 () 00 x 860 () 50 () 8 x 33.5 () 736 () 740 () 00 x 880 () 560 () 8 x 34 () 808 () 760 () 00 x 900 () 600 () 8 x 35 () 880 () 780 () 00 x 90

6 Model CA-W Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety, health, comfort and productivity of kitchen staff. The hood is installed two metres (six feet, six inches) above the floor and overhangs cooking units by approximately 300 mm ( inches). Operation Hot air, smoke and grease vapours rise towards the hood just above. The air flow from cooking surfaces is drawn through the filters to remove grease particles and deposit them in a trough running to a grease cup at one end. Exhaust The quantity of air exhausted depends upon the type of cooking equipment installed under the hood. When heated by the cooking surfaces, smoke and grease laden air rise towards the exhaust hood (see the Thermal currents Chart). Construction All stainless steel construction,.09 mm, (8 MSG) thick, type 304, with no. 4 finish on apparent surfaces. Each section of the hood is equipped with mounting tabs. Exhaust Ducts All exhaust ducts are installed according to NFPA 96. Horizontal ducts must be sloped towards the exhaust duct collar to avoid liquid accumulation. Fire Suppression System According to NFPA 96 and the National Building Code, the use of this type of hood requires a fire suppression system to protect the filter bank, the exhaust ducts and cooking equipment. The system is activated by fusable links or thermal detectors located inside the hood. In case of fire, air exhaust is maintained but make-up air supply is interrupted. The filter bank, exhaust ducts and cooking surfaces are sprayed with a chemical product. Gas and electricity to the cooking equipment and lighting are interrupted and an alarm rings. HOOD LISTED Manufactured in accordance with NFPA 6

7 Model CA-W D P w DP 80 w x H 300 " " L PLAN SIDE PROFIL VIEW - Mounting tabs - Exhaust duct collar 7 - Junction box 0 volts 4 - Grease cup - maximum capacity 500 ml 5 - Stainless steel filters U.L.C. Iisted 80 - Sealed fluorescent light fixture 80 W - 0// Sealed incandescent light fixture 00 W -0// Mechanical joint for shipment Weight in Kg. per Metre of Lineal Hood Depth: kg/m: Weight in Pounds per Foot of Lineal Hood Depth: Lbs/ft: SIZE L: D: H: X: Total Air Exhaust: SUGGESTED SPECIFICATIONS Size: Length: Depth: Height: installed 000 mm (78 inches) from the floor. Description: CA D E XA I R, model CA-W- ( ), island type, supplied with stainless steel baffle filters. The hood is ULC approved and is built according to NFPA 96. Construction: The housing of the hood is made of # 304 stainless steel.09 mm thick (8 MSG) with # 4 finish on apparent surfaces. All welded joints are polished to the original finish. Each section of the hood is equipped with mounting tabs and grease cup. Skirting: The space between the top of the hood and the ceiling is enclosed by stainless steel panels with the same finish as the hood. Lighting: fluorescent light fixtures with two tubes, vapour proof, watts, volts, phase, cycle, 00 mm (48 inches) in length, incandescent light fixtures, vapour proof, watts, volts, phase, cycle, wired to a junction box. Work by Ventilation Contractor: Connect exhaust duct collar, located on the top of the hood, to the exhaust system. All exhaust ductwork must be installed according to NFPA 96 and be sloped towards the hood duct collar to avoid liquid accumulation. Work by Electrical Contractor: Supply and install lighting wiring from control panel to junction box on top of the hood.

8 Model CA-W-PE Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety, health, comfort and productivity of kitchen staff. The hood is installed two metres (six feet, six inches) above the floor and overhangs cooking units by approximately 300 mm ( inches). Operation Hot air, smoke and grease vapours rise towards the hood just above. The air flow from cooking surfaces is drawn through the filters to remove grease particles and deposit them in a trough running to a grease cup at one end. Exhaust The quantity of air exhausted depends upon the type of cooking equipment installed under the hood. When heated by the cooking surfaces, smoke and grease laden air rise towards the exhaust hood (see the Thermal currents Chart). Make Up Air An air supply housing, made of insulated stainless steel is secured to both fronts of the hood. The replacement air is diffused and directed towards the ceiling with the use of stainless steel grills built into the housing. This low projection feature limits air movement to the zone surrounding the cooking equipment. Construction All stainless steel construction,.09 mm, (8 MSG) thick, type 304, with no. 4 finish on apparent surfaces. Each section of the hood is equipped with mounting tabs. Exhaust Ducts All exhaust ducts are installed according to NFPA 96. Horizontal ducts must be sloped towards the exhaust duct collar to avoid liquid accumulation. Fire Suppression System According to NFPA 96 and the National Building Code, the use of this type of hood requires a fire suppression system to protect the filter bank, the exhaust ducts and cooking equipment. The system is activated by fusable links or thermal detectors located inside the hood. In case of fire, air exhaust is maintained but make-up air supply is interrupted. The filter bank, exhaust ducts and cooking surfaces are sprayed with a chemical product. Gas and electricity to the cooking surfaces and lighting are interrupted and an alarm rings. HOOD LISTED Manufactured in accordance with NFPA 6

9 Model CA-W-PE DP " 5 " 00 z x 0 8 H " " 7 D P 400 6" " " 00 H y " L PLAN - Mounting tabs - Exhaust duct collar 3 - Junction box for lights 0 volts 4 - Grease cup 5 -Stainless steel filters ULC listed 0 -Supply duct collar - 50 mm ( inches) high -Insulation - 5 mm ( inch) thick 3 - Integrated stainless steel grill 80 - Sealed fluorescent light fixture 80 W - 0// Sealed incandescent light fixture 00 W - 0// Mechanical joint for shipment SUGGESTED SPECIFICATIONS Size Length: Depth: Height installed 000 mm (78 inches) from the floor. Description: CADEXAIR, model CA-W-PE- ( ), (island type), supplied with stainless steel baffle filters. Stainless steel grills are built into the insulated front housing to supply replacement air from the front of the hood. The hood is ULC approved and is built according to NFPA 96. Construction: The housing of the hood is made of # 304 stainless steel.09 mm thick (8 MSG) with # 4 finish on apparent surfaces. All welded joints are polished to the original finish. Each section of the hood is equipped with mounting tabs and grease cup. Skirting: The space between the top of the hood and the ceiling is SIDE VIEW Weight in kg. per Metre of Lineal Hood Depth: kg/m: Weight in Pounds per Foot of Lineal Hood Depth: Lbs/ft: SIZE L : D : H : x : y : z: Total Air Exhaust: enclosed by stainless steel panels with the same finish as the hood. Lighting: fluorescent light fixtures with two tubes, vapour proof, watts, volts, phase, cycle, 00 mm (48 inches) in length, incandescent light fixtures, vapour proof, watts, volts, phase, cycle, wired to a junction box. Work by Ventilation Contractor: Connect exhaust duct collar, located on the top of the hood, to the exhaust system. All exhaust ductwork must be installed according to NFPA 96 and be sloped towards the hood duct collar to avoid liquid accumulation. Work by Electrical Contractor: Supply and install lighting wiring from control panel to junction box on top of the hood.

10 Air Volume Chart W Exhaust duct collar sizes are based on a velocity of 9 metres per second (700 fpm). Make-up air duct collar sizes are based on a velocity of 5 metres per second (000 fmp). Static pressure at the exhaust duct collar (B) is 30 mm (. inch) of water column or 300 Pa. Static pressure at the make-up air duct collar (C) is 0 mm (0.4 inch) of water column or 00 Pa. Exhaust Opening Exhaust flow rate A + A x length of extractor Maximum air throw:.5 M (5 ft) Make-up air volume based on 80% of exhaust volume CFM Opening m 3 /h L/s Opening CFM Opening m 3 /h L/s Opening x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 340 A EXHAUST FLOW RATE See Thermal Currents Chart COOKING EXHAUST FLOW RATE EXHAUST FLOW RATE IN EXHAUST FLOW RATE IN GREASE EXTRACTOR EQUIPMENT IN CFM/FT L/s PER METRE m 3 /h PER METRE ADJUSTMENT IN mm Very light (ovens) Light, Electric (counter equipment) Light, Gas (counter equipment) Medium, Electric (restaurants) Medium, Gas (restaurants) Heavy Duty, Electric (hotels, institutions) Heavy Duty, Gas (hotels, institutions) Very Heavy Duty, Electric (charbroiler) Very Heavy Duty, Gas (charbroiler) B Make-up Air Opening () 400 () 8 x () 576 () 60 () 00 x 50 () 480 () 8 x 3 () 70 () 00 () 00 x 300 () 560 () 8 x 5 () 864 () 40 () 00 x 340 () 640 () 8 x 6 () 008 () 80 () 00 x 400 () 70 () 8 x 8 () 5 () 30 () 00 x 440 () 800 () 8 x 9 () 96 () 360 () 00 x 480 () 880 () 8 x () 440 () 400 () 00 x 50 () 960 () 8 x 3 () 584 () 440 () 00 x 560 () 040 () 8 x 5 () 78 () 480 () 00 x 60 () 0 () 8 x 6 () 87 () 50 () 00 x 650 () 00 () 8 x 7 () 06 () 560 () 00 x 690 () 80 () 8 x 9 () 60 () 600 () 00 x 740 () 360 () 8 x 3 () 304 () 640 () 00 x 780 () 440 () 8 x 3 () 448 () 680 () 00 x 80 () 760 () 8 x 8 () 96 () 360 () 00 x 480 () 800 () 8 x 9 () 368 () 380 () 00 x 500 () 840 () 8 x 0 () 440 () 400 () 00 x 50 () 880 () 8 x () 5 () 40 () 00 x 540 () 90 () 8 x () 584 () 440 () 00 x 560 () 960 () 8 x 3 () 78 () 460 () 00 x 590 () 000 () 8 x 4 () 800 () 480 () 00 x 60 () 040 () 8 x 5 () 87 () 500 () 00 x 630 () 080 () 8 x 5.5 () 944 () 50 () 00 x 650 () 0 () 8 x 6 () 06 () 540 () 00 x 670 () 60 () 8 x 6.5 () 088 () 560 () 00 x 690 () 00 () 8 x 7 () 60 () 580 () 00 x 70 () 40 () 8 x 8 () 3 () 600 () 00 x 740 () 80 () 8 x 9 () 304 (0 60 () 00 x 760 () 30 () 8 x 30 () 376 () 640 () 00 x 780 () 360 () 8 x 3 () 448 () 660 () 00 x 800 () 400 () 8 x 3 () 50 () 680 () 00 x 80 () 440 () 8 x 3.5 () 59 () 700 () 00 x 840 () 480 () 8 x 33 () 664 () 70 () 00 x 860 () 50 () 8 x 33.5 () 736 () 740 () 00 x 880 () 560 () 8 x 34 () 808 () 760 () 00 x 900 () 600 () 8 x 35 () 880 () 780 () 00 x 90 C 5

11 Thermal Currents Chart The air exhaust volume for a kitchen exhaust hood must correspond to the volume of air (Thermal Current) produced by cooking equipment. THERMAL CURRENTS Type ELECTRICAL GAS of cooking equipment Warmer Sandwich Unit Steamer Oven Closed Roaster Countertop Hot Plate Kettle Fryer (counter style) Braising Pan Open Roaster Salamander Range (restaurant type) Fryer (floor type) Griddle Heavy Duty Range Hot Top Range Upright Broiler Charcoal Broiler Wok Heavy Duty Charcoal Broiler Mesquite Charcoal Broiler EXHAUST PERFORMANCE - The minimum air speed in exhaust duct is.54 M/s (500 feet per minute). L/s per m3/h per CFM L/s per M3/h per CFM lineal lineal per lineal lineal lineal per lineal metre metre foot metre metre foot A kitchen exhaust hood must exhaust a sufficient air volume to capture the thermal current produced by cooking equipment. 3- Generally, a kitchen exhaust hood must overhang cooking equipment by approximately 300 mm ( inches) on all sides that are not installed against a wall. 6

Model ND-2 Specification

Model ND-2 Specification Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction

More information

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets KVR Capture Jet Round Island Hood with Perimeter Jets The KVR Round Island Capture Jet hood with perimeter jets is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat

More information

When Time Matters! listed Fire Damper

When Time Matters! listed Fire Damper listed Fire Damper The FAST fire damper is offered as an option for containing fire and smoke under the hood in the event of a fire from a cooking appliance. Construction : The fire damper is assembled

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Commercial Kitchen Hood Installation, Operation and Maintenance Manual www.fastkitchenhood.com General Information Prior to installing the stainless steel ventilation hood, the installing contractor should

More information

KVL-P with Plate Shelf

KVL-P with Plate Shelf The model of Capture Jet TM hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment, helping to provide a comfortable and clean environment.

More information

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood Capture Jet Hybrid Backshelf Hood The hybrid backshelf model of Capture Jet hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment,

More information

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology KWT GALLEY WATER WASH HOOD With supply air and Capture Jet technology APPLICATIONS Halton KWT is a galley water wash hood for use in marine & offshore applications. The highly efficient KWT hood uses Halton

More information

Kitchen Ventilation Systems. Exhaust Hoods & Grease Extraction Fire Suppression Systems Accessories

Kitchen Ventilation Systems. Exhaust Hoods & Grease Extraction Fire Suppression Systems Accessories Kitchen Ventilation Systems Exhaust Hoods & Grease Extraction Fire Suppression Systems Accessories September 2009 Table of Contents Greenheck s comprehensive line of kitchen ventilation products are designed

More information

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES 58 59 VAPORPROOF RECESSED INCANDESCENT LIGHT FIXTURE VAPORPROOF LIGHT FIXTURES RECESSED INCANDESCENT LIGHT FIXTURE Specifications Cut-Out Mounting Diagram Socket: Side mounted porcelain

More information

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for

More information

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for

More information

Part 1 of this series discussed optimizing outdoor

Part 1 of this series discussed optimizing outdoor Many methods await when it comes to reducing exhaust rates. Fortunately, engineers can avail themselves of multiple tactics, from the hood specification to proper commissioning and air balance. By Doug

More information

Gaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report

Gaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Gaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Test Method F 1704-05 Food Service Technology Center (www.fishnick.com) -R1 Prepared

More information

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for

More information

Optimizing System Performance

Optimizing System Performance Commercial Kitchen Ventilation Optimizing System Performance using Green Tips, Tricks & Technologies from FSTC Research! What can make a hood work better? 9 times out of 10 it is NOT more exhaust! What

More information

J L I e x h a u s t h o o d

J L I e x h a u s t h o o d JLI exhaust hood PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air 7 Pressure loss & Sound data, Lights 8 We want

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

Gaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report

Gaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Gaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Method F1704-09 FSTC Report 5011.09.06-R1 Food Service Technology Center Prepared by:

More information

Zoneflow Engineering Installation and Maintenance Manual

Zoneflow Engineering Installation and Maintenance Manual Zoneflow Engineering Installation and Maintenance Manual Introduction The Cadexair ZoneFlow is designed to be installed in a commercial kitchen NFPA-96 central exhaust fan duct system up stream of each

More information

Zoneflow Engineering, Installation, and Maintenance Manual

Zoneflow Engineering, Installation, and Maintenance Manual Zoneflow Engineering, Installation, and Maintenance Manual Spring Air Systems Inc., Oakville, Ontario Phone (905) 338-2999, Fax (905) 338-0179, info@springairsystems.com www.springairsystems.com Zoneflow

More information

Operators Manual for JES-HD

Operators Manual for JES-HD Operators Manual for JES-HD Heavy Duty Jet Extraction System Manual provides Operation, Maintenance and Service Instructions Heavy Duty Jet Extraction System Model: JES-HD Form#: OM038_JES-HD_Jet_Extraction_System

More information

Spring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report

Spring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report Spring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Test Method F1704-09 FSTC Report 501311275 Food Service Technology Center Prepared

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

ExtractAire. Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC)

ExtractAire.  Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC) ExtractAire Grease Filters for Commercial Kitchen Ventilation Hoods 50% Efficient 100% Efficient High Velocity Cartridge Multi-Stage* (HVCMS) US Patent No. 6,394,083 High Velocity Cartridge (HVC) Grease

More information

KVI Kitchen Canopy With Capture Air

KVI Kitchen Canopy With Capture Air KVI Kitchen Canopy With Capture Air SCHLIEREN THERMAL IMAGING SYSTEM Capture Jet on Capture Jet off SAME EXHAUST RATES, DIFFERENT RESULTS The KVI is a highly efficient kitchen ventilation canopy that removes

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

KWF Water Wash Canopy with Supply Air

KWF Water Wash Canopy with Supply Air KWF Water Wash Canopy with Supply Air SCHLIEREN THERMAL IMAGING SYSTEM Photographer: Matti Lehto The KWF is a highly effective kitchen ventilation canopy for the removal of contaminated air and excess

More information

W-VI Series - Internal Make-up Air Wall Canopy

W-VI Series - Internal Make-up Air Wall Canopy W-VI Internal Make-up ir Wall Canopy With Diffuser W-VI single shell combination internal make-up air/air curtain canopy constructed of stainless steel where visible and aluminized steel where concealed.

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

Hoods for professional kitchens

Hoods for professional kitchens Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

Alarge portion of kitchen ventilation planning is dedicated to

Alarge portion of kitchen ventilation planning is dedicated to By Richard T. Swierczyna, Associate Member ASHRAE, & Paul A. Sobiski, Associate Member ASHRAE Alarge portion of kitchen ventilation planning is dedicated to properly exhausting cooking effluent. Appliance

More information

OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR

OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS

More information

DW Series - Exhaust Only Wall Canopy

DW Series - Exhaust Only Wall Canopy DW Exhaust Only Wall Canopy Model DW A single shell non-compensating exhaust only wall hung canopy constructed of stainless steel where visible and aluminized steel in concealed locations. All external

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

Actionair Flame/Shield

Actionair Flame/Shield pril 2000 ctionair djustable Coated affle Grease Filters ange and Features Single Sided and Double Sided Stainless Steel casings with a choice of factory assembled arrangements. Non grease loading adjustable

More information

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service

More information

Hoods for professional kitchens

Hoods for professional kitchens Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves

More information

HEAVY DUTY RANGES GRIDDLE TOP

HEAVY DUTY RANGES GRIDDLE TOP GRIDDLE TOP Model Numbers IHR-G36 IHR-GT36 IHR-G36-C IHR-GT36-C IHR-G36-XB IHR-GT36-XB IHR-G36-M IHR-GT36-M 1" (25 mm) thick steel polished griddle plate. M shaped burner for even heating throughout the

More information

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 452413 Kitchen Hoods Type I and Type II Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

ENVIRO UNIT CES SERIES

ENVIRO UNIT CES SERIES ENVIRO UNIT CES SERIES ENVIRO UNIT FILTER BOX Commercial Kitchen Exhaust CES-ISH 1,000 to 40,000 CFM Operation The grease laden air rises from the cooking equipment into the NFPA- 96 commercial kitchen

More information

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO.

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO. RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO. For over 75 years, Van-Packer has supplied venting products to the Commercial and Industrial heating and process markets. For the past 30

More information

Requires Ductwork and Blower

Requires Ductwork and Blower 6' Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Requires Ductwork and

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy Hoods A Applications involving perchloric acid, acid

More information

SECTION DUCTWORK ACCESSORIES

SECTION DUCTWORK ACCESSORIES SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference

More information

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Protector XStream Laboratory

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

Design Criteria for CSA Kitchen Suppression Assessments (CKH2 & FEKH2)

Design Criteria for CSA Kitchen Suppression Assessments (CKH2 & FEKH2) Design Criteria for CSA Kitchen Suppression Assessments (CKH2 & FEKH2) This manual shall be studied and used as the bases of design criteria for CSA exams on kitchen hood suppression systems. This manual

More information

EGG CRATE RETURN GRILLE

EGG CRATE RETURN GRILLE 80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders

More information

OVERVIEW Combination Supply/Return Diffuser (SARM)

OVERVIEW Combination Supply/Return Diffuser (SARM) OVERVIEW Combination Supply/Return Diffuser (SARM) APPLICATION INFORMATION The extruded aluminum square and rectangular supply and return diffusers are designed principally for packaged roof top type heating

More information

Commercial Kitchen Ventilation Exhaust Hoods

Commercial Kitchen Ventilation Exhaust Hoods ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at www.fishnick.com. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FOOD SERVICE TECHNOLOGY CENTER 12949 Alcosta Blvd Suite 101 San Ramon, CA 94583 Richard Swierczyna Phone: 925-866-2844 Email: rswierczyna@fishnick.com MECHANICAL

More information

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com PRODUCT BROCHURE Rectangular Displacement Diffuser RDW-FD smartemp.com DESCRIPTION The SMARTEMP Rectangular Displacement Diffuser, type RDW-FD (figure 1), produces a low velocity horizontal airflow pattern

More information

Pro Island Ventilation Hoods

Pro Island Ventilation Hoods INSTALLATION GUIDE Pro Island Ventilation Hoods READ AND SAVE THESE INSTRUCTIONS Contents Wolf Pro Island Ventilation Hoods................. 3 Safety Instructions............................ 4 Installation

More information

THE GAYLORD VENTILATOR TECHNICAL MANUAL FOR THE GRAND VH2 AND HH SERIES TYPE II HOODS GAYLORD INDUSTRIES

THE GAYLORD VENTILATOR TECHNICAL MANUAL FOR THE GRAND VH2 AND HH SERIES TYPE II HOODS GAYLORD INDUSTRIES EFFECTIVE DATE 5-04 THE GAYLORD VENTILATOR TECHNICAL MANUAL FOR THE GRAND VH2 AND HH SERIES TYPE II HOODS 10900 S.W. AVERY STREET P.O. BOX 1149 TUALATIN, OREGON 97062-1149 U.S.A. 800-547-9696 503-691-2010

More information

Commercial Kitchen Hoods Installation, Operation, and Maintenance Manual

Commercial Kitchen Hoods Installation, Operation, and Maintenance Manual Commercial Kitchen Hoods Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to

More information

Halton - Advanced Air Purification, Now with ELF Extended Life Filters!

Halton - Advanced Air Purification, Now with ELF Extended Life Filters! Halton - Advanced Air Purification, Now with ELF Extended Life Filters! Meets NYC Emission Requirements. Enabling Wellbeing Form#: BR-007 EcoloAir Brochure ECOLOAIR - ECOLO Halton has the equipment, design

More information

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC K Table of Contents, This series of extruded aluminum supply and return linear bar grilles are for ceiling, sidewall, sill (), and floor () applications. Blade thickness is 7/32., This series of extruded

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

SERIES C. Adjustable Deflection Grilles for Circular Ducting

SERIES C. Adjustable Deflection Grilles for Circular Ducting SERIES C Adjustable Deflection Grilles for Circular Ducting PUBLICATION GRILLES 18 APRIL 2012 Features - Designed for circular duct applications - Single or double deflection - Individually adjustable

More information

Accessories Standard Service Fixture Kits

Accessories Standard Service Fixture Kits Standard Service Fixture Kits For mounting on the left or right side of any Protector Premier, XStream, XL, XLE or PVC Hood. Each kit includes one remotely-controlled service fixture with valve and 0.25"

More information

Electrical Control Panel

Electrical Control Panel Electrical Control Panel Kitchen Ventilation Control System Installation and Operations Manual Photo to Come FOR MODELS: ECP Striving for Excellence STREIVOR.COM Table of Contents General Information Pre-Installation

More information

ISLAND RANGE HOOD SPECIFICATIONS

ISLAND RANGE HOOD SPECIFICATIONS ISF18/ISFH18/ISL18/ISLH18/IXR18/IXRH18 H in part number indicates halogen lighting. These models not available with heat lamps. ISF18/ISFH18 ISL18/ISLH18 IXR18/IXRH18 11" 11" Dia. Island Duct Cover 9 550

More information

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Item Number-1 ----------------------------------------------------------------------------------------------------------

More information

Operators Manual. Manual provides Installation and Operating Instructions. Model MM1 Series Hood

Operators Manual. Manual provides Installation and Operating Instructions. Model MM1 Series Hood Operators Manual Manual provides Installation and Operating Instructions Model MM1 Series Hood 1 General Description Halton s MM1 Series hood is designed to efficiently capture and remove the grease, smoke,

More information

WhispAire Range Hood Quiet Hood

WhispAire Range Hood Quiet Hood INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS WhispAire Range Hood Quiet Hood IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELEC- TRIC SHOCK, OR INJURY TO PERSONS, OBSERVE

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

5/S1 KITCHEN HOODS NZK, NZR, NZP, NSK, NSR, NSP, NES, NEZ. v 2.6 (en)

5/S1 KITCHEN HOODS NZK, NZR, NZP, NSK, NSR, NSP, NES, NEZ. v 2.6 (en) 5/S v. (en) NZ, NZR, NZP, NS, NSR, NSP, NES, NEZ www.klimaoprema.hr www.klimaoprema.hr 7 TAE CNTENTS Types and sizes... 9 Conventional wall s... Conventional ceiling s... Economic s... Accessories... Construction

More information

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION. Non-Welded Grease Duct Systems Installation, Operation, and Maintenance Manual FOR YOUR SAFETY TWO MAJOR CAUSES OF GREASE DUCT RELATED FIRES: (1) FAILURE TO MAINTAIN REQUIRED CLEARANCE (AIR SPACE) TO COMBUSTIBLE

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10

More information

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Connection Diagrams (36 - 48 Widths) Wall Side 1 ¾. Connection Diagram (48 - 60 Widths) (Front View) Connection Diagram (54 - 66 Widths) R DESIGNER SERIES WALL MOUNT RANGE HOOD JPH/C2 Series Equipped with LED lighting. Not available with heat lamps. Optional duct covers available in standard and custom sizes. Recommended Mounting Height

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

Connection Diagrams (36 - 48 Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48 - 60 Widths) R DESIGNER SERIES WALL MOUNT RANGE HOOD JDH/C2 Series Equipped with LED lighting. Not available with heat lamps. Optional duct covers available in standard and custom sizes. Recommended Mounting Height

More information

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style. 120 Ventilation Ventilation Removes smoke and odor. Adds exceptional style. Ventilation 121 Ventilation Bosch s efficient, highly effective ventilation products complete any Bosch kitchen package. Capable

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

Duct Nozzle Diffuser. L e

Duct Nozzle Diffuser. L e Duct Nozzle Diffuser L-08-1-08e Contents Application Construction Safety instructions Contents Application Construction Safety instructions 2 Dimensions 3 Quick selection for ducts with 1 to 3 rows of

More information

! FOR DOMESTIC COOKING ONLY!

! FOR DOMESTIC COOKING ONLY! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer

More information

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation ADRIATIC VF Climate beam Adriatic Adriatic is an enclosed climate beam with integrated

More information

RA-7730SS RA-7736SS RA-7742SS RA-7748SS. For residential and indoor use only.

RA-7730SS RA-7736SS RA-7742SS RA-7748SS. For residential and indoor use only. RA-7730SS RA-7736SS RA-7742SS RA-7748SS For residential and indoor use only. 4 Limited Warranty P.15-P.16 WINDSTER recommends that all kitchen range hood be installed by a certified installer. 27 35 27-35

More information

January, 2014 Page 1 of 6

January, 2014 Page 1 of 6 Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying chemical fume hood modifications or installations. These standards are not intended to restrict or replace

More information

CHAPTER III SYSTEM DESIGN

CHAPTER III SYSTEM DESIGN Chapter 3 System Design CHAPTER III SYSTEM DESIGN GENERAL This section will cover the proper design of the Protex Series II Restaurant Fire Suppression System. It is divided into four (4) sections: Cylinder

More information

ISLAND INSTALLATION WALL INSTALLATION

ISLAND INSTALLATION WALL INSTALLATION HEIGHT OF HOOD The bottom of the hood should be 30 (76.2 cm) min. to 36 (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (175.3 cm) above

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

FLAT ELECTRIC SANDWICH GRILLS

FLAT ELECTRIC SANDWICH GRILLS FLAT ELECTRIC SANDWICH GRILLS SASL SSGL Heavy Duty Stainless steel body Cast aluminum grid plate Adjustable temperature control Uniform Heating Easy to use and clean Ideal for sandwiches, cooking meat,

More information

Ceiling impulse diffuser Model PIL

Ceiling impulse diffuser Model PIL Ceiling impulse diffuser Model PIL Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

AIR CURTAINS AIR CHAMBER DESIGN

AIR CURTAINS AIR CHAMBER DESIGN AIR CURTAINS AIR CHAMBER DESIGN Pittsburgh, PA Akron, OH Atlanta, GA Los Angeles, CA INDEX How an Air Curtain Works...3 Making an Air Curtain...3 Choosing The Right Air Curtain...4-5 Energy Saving & Return

More information

CANOPY HOOD ACCESSORIES

CANOPY HOOD ACCESSORIES CANOPY HOOD ACCESSORIES CONTENTS ITEM PAGE ITEM PAGE GREASE FILTERS TRAPPER...K2-3 affle....k4-5 FILTER RACKET... K5 LIGHTING... K6, K8-10 CAP STRIPS... K6 DIVIDER ARS... K6 GREASE CUPS.... K6 SILICONE

More information

LOW PRESSURE MIXED FLOW FANS

LOW PRESSURE MIXED FLOW FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS LOW PRESSURE MIXED FLOW FANS QCLB QCLBR QCLBSH CATALOG 1070 JANUARY 2017 MIXED FLOW FANS Models QCLB QCLBR QCLBSH QCLB (Horizontal) Benefits

More information

DCG Adjustable Aluminum Round Diffusers

DCG Adjustable Aluminum Round Diffusers 51 DCG Adjustable Aluminum Round Diffusers H V A C TM Rev 27-05-2018 52 DCG SEries Aluminum Adjustable Round Diffusers Adjust core up and down to move from horizontal to vertical airflow Architecturally

More information

F. VAV hoods shall have a restricted bypass plate.

F. VAV hoods shall have a restricted bypass plate. 1.01 SUMMARY A. Section Includes: 1. Laboratory fume hoods. B. Related Sections: 1. Section 6500 Laboratory casework 2. Section 15 Mechanical: Furnishing and installation of plumbing utilities and final

More information

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat) Air Moving Solutions. low pressure mixed flow fans QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat) BULLETIN 1070 February 2012 MixedFlowFans Models QCLB QCLBR QCLBSH Benefits of Mixed Flow Fans Twin City

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

SPD SQUARE PLAQUE DIFFUSER

SPD SQUARE PLAQUE DIFFUSER SQUARE PLAQUE DIFFUSER The (SPD) has a flush appearance, making it ideal for architecturally-conscience commercial spaces, and provides industry-leading low pressure drop and sound generation with a 360

More information

Premium Correctional Air Distribution. The First Name in Air Diffusion.

Premium Correctional Air Distribution. The First Name in Air Diffusion. Premium Correctional Air Distribution The First Name in Air Diffusion www.anemostat.com PRODUCT DIRECTORY APPLICATIONS Stainless Steel S-Vent MAXIMUM SECURITY GRILLES NEW CONSTRUCTION page 16 page 4 &

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Professional Series Built-In Chimney-Style Hoods Viking Range Corporation 111 Front Street Greenwood, MIssissippi 38930 USA NOTE: IF INSTALLING HOOD WITH WARMING SHELF PANEL,

More information