SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 PP SYSTEM 100 ALSIDENT SYSTEM 75. Chemical Resistant (CR) Product Information
|
|
- Francis Lester
- 6 years ago
- Views:
Transcription
1 ALSIDENT SYSTEM 75 Chemical Resistant (CR) Product Information
2
3 System 75 Chemical Resistant (CR) General Information Product Specification Product Description System 75 Chemical Resistant (CR) Alsident System airflow between m³/h. System 75 Chemical Resistant is suitable in working environments where there are special requirements for chemical resistance such as laboratories, hospitals, chemical-, pharmaceutical- and food industry. The standard Alsident System extraction arms are available in various types that are complementary to each other with ranges up to mm. The System extraction arms are easily mounted with standard brackets for table, wall or ceiling. In combination with the wide range of hood designs this makes it possible to choose an extraction arm adapted for each work situation. Alsident System extraction arms are self-sustaining with an internal bearing spring, pipes of Polypropylene (PP) with a diameter of 75 mm and joints of Polypropylene (PP). All internal components are of acid-proof stainless steel (AISI 316L). The longest model for wall and ceiling mounted is available with two external gas springs. The construction constitutes a very user-friendly extraction arm that is easy to adjust to the source of the pollutant during the working process. An extraction arm from Alsident System consists of three parts: An extraction arm, a hood and a mounting bracket. Each part must be ordered separately. In addition to the standard range, Alsident System offers special customized solutions. The Alsident technical department is always ready to help you find the best solution. Alsident offers short delivery time for both standard productions and special solutions. GI 01
4 System 75 Chemical Resistant (CR) General Information Product Specification Technical Specifications Recommended Airflow: Normal: 140 m 3 /h Air Temperature: Key to the signatures SYSTEM NO. 75 Minimum: 80 m 3 /h Maximum: 180 m 3 /h -15 C +90 C Material: Pipes: Polypropylene (PP) white Joints: O-rings: Mounting Flanges: Damper: Thumbscrew: VERSION AL Aluminium Polypropylene (PP) red or white Polyethylene (PE) Polypropylene (PP) red or white Polypropylene (PP) Polypropylene (PP) black Threades Stay: Acid-proof stainless steel (AISI 316L) Spring 1) : Acid-proof stainless steel (AISI 316L) Gas spring 2) : Stainless Steel 3) 1) Extraction arms with ranges up to 1550 mm 2) Avaliable on models and ) Also available in stainless steel on request Abbr.: PP: Polypropylene Shatterproof and chemical resistant PE: PETG: Polyethylene Polyethylen Therephthalat, Glycol-modified Transparent and resistant to solvents Local Extraction for workplaces incl. all materials for mounting. All components RoHS-compatible according to the directive 2002/95/EF (RoHS). CHAPTER GI TM WM CM General Information Table Mounted Wall Mounted Ceiling Mounted PAGE 01 GI 02
5 System 75 Chemical Resistant (CR) General Information Product Overview Table mounted Table mounted (TM), 2-joint Diam. L B C Weight Part No. Colour of joint [mm] [mm] [mm] [mm] ca. [kg] Red White Table mounted (TM), 3-joint Diam. L A B C Weight Part No. Colour of joint [mm] [mm] [mm] [mm] [mm] ca. [kg] Red White GI 03
6 System 75 Chemical Resistant (CR) General Information Product Overview Wall- and Ceiling mounted Wall- and Ceiling Mounted (WM/CM), 3-joint Diam. L A B C Weight Part No. Colour of joint [mm] [mm] [mm] [mm] [mm] ca. [kg] Red White * ** -4-5 *) With 1 external gas spring **) With 2 external gas springs GI 04
7 System 75 Chemical Resistant (CR) General Information Accessories Overview Extractor tube Hoods Extractor tube (250 mm) Part No.: /-5 Recommended for small concentrated sources of pollution. Efficient as it gets close to the source without obstructing the work process. Tip with funnel increases the extraction efficiency. Material Tube: Polypropylene (PP) 1, white Tip: Polypropylene (PP) 1, red or white Part No. Red tip White tip ) See pge GI02 Dome Hood (diam. 385 mm) Part No.: /-5 Recommended for light fumes, gases and small open vessels. Increased stability due to reinforced rim of the hood. Increased efficiency at an angled position. Material Hood 3) : Polypropylene (PP) 1, white Flange: Polypropylene (PP) 1, red or white Connection tube 2) : Polypropylene (PP) 1, white 1) See pge GI02 2) Separately enclosed at delivery 3) Also available in clear PETG on request Part No. Flange, red Flange, white Flat Screen (330 x 240 mm) Part No.: /-5 Recommended when extracting heavy gases and fumes. High efficiency when placed vertically on a surface e.g. a table. Practical rim for easy positioning of the hood. Gets close to the source without obstructing the work process. Material Hood 3) : Polypropylene (PP) 1, white Flange: Polypropylene (PP) 1, red or white Connection tube 2) : Polypropylene (PP) 1, white 1) See pge GI02 2) Separately enclosed at delivery 3) Available in clear PETG on request Part No. Flange, red Flange, white GI 05
8 System 75 Chemical Resistant (CR) General Information Accessories Overview Square Hood (420 x 320 mm) Part No.: /-5 Recommended for both light and heavy fumes, gases and for open vessels, as this hood is suited for horizontal position above and vertical position behind the source of pollution. Good efficiency when placed verticlly on a surface e.g. a table. Increased stability due to reinforced rim of the hood. Material Hood 3) : Polypropylene (PP) 1, white Flange: Polypropylene (PP) 1, red or white Connection tube 2) : Polypropylene (PP) 1, white 1) See pge GI02 2) Separately enclosed at delivery 3) Also available in clear PETG on request Part No. Flange, red Flange, white Dome Hood (diam.200 mm) Part No.: /-5 Recommended for lightfumes, gases, and open vessels. Material Hood: Aluminium, powder coated white or red Flange: Polypropylene (PP) 1, white or red Connection tube: Polypropylene (PP) 1, white Part No. Red hood White hood ) See pge GI02 GI 06
9 System 75 Chemical Resistant (CR) General Information Accessories Overview Brackets and Reducer Wall bracket Part No.: and Used for System 75 Wall Mounted Extraction Arms. The wall bracket is made of white polyester powder coated steel. Other colours available on request. 2 The bracket with both sides closed is suitable for all applications with special requirements to cleaning. See photo page WM 03. Colour Open sides Closed sides White Table bracket Part No.: Used to mount System 75 Table Mounted Extraction Arms on table side which makes it removable for mobile installations. Made of black polyester powder coated steel. Other colours available on request. Reducer Part No.: / Used to connect System75 Extraction Arms to duct. Made of white polypropylene (PP). Available in two sizes. Reduces from/to [mm] Part No. 80/ / GI 07
10 System 75 Chemical Resistant (CR) General Information Accessories Overview Brackets and Ceiling Columns Ceiling columns Used for mounting the System 75 Ceiling Mounted Extraction Arms. The ceiling column is made of white polyester powder coated steel. Available in two models with side connection or top connection to duct. For standard lengths see below. Other lengths, colours and acidproof stainless steel available on request. Connection Diameter: With side connection: 80 mm With top connection: max. 100 mm Length [mm] Weight app. [kg] Top connection Side connection Support Bracket for long ceiling column Part No.: For extra support of ceiling columns longer than 2 m. For support with wire to check or by fastening to ceiling rail system. The support bracket is made of steel with a white polyester powder-coating. Other colours available on request. GI 08
11 System 75 Chemical Resistant (CR) General Information Technical Description Table mounted C Pressure Drop Chart Tested by Danish Technological Institute (Teknologisk Institut) Væg- and Ceiling Mounted D C D GI 09
12 System 75 Chemical Resistant (CR) General Information Spare Parts List Joint with Damper Joint with Damper /-5 Pos. A Product No / Pos. Part No. Red White Description A Joint, 12 mm Joint, 5 mm O-ring Teflon Washer Thumbscrew, 5 mm Threaded Stay Thumbscrew, 4 mm Wing for Damper Damper Seegerring [pieces applied] GI 10
13 System 75 Chemical Resistant (CR) Table mounted (TM) Working Area Table mounted with Extractor tube Note: A: Model R: 550 mm B: Model R: 650 mm C: Model R: 750 mm D: Model R: 830mm E: Model R: 1105 mm F: Model R: 1290mm G: Model R: 1620 mm The working area of the arm is defined from the center of the opening of the accessory. The working area changes according to type of accessory and positioning. When choosing the arm we recommend that the stationary working position of the accessory is not placed in the highest or lowest part of the working area. (All measurements in mm) Accessory: Extractor tube No TM 01
14 System 75 Chemical Resistant (CR) Table mounted (TM) Mounting Options Table Mounted Option Dimensions Directly on Table System 75 Extraction Arm mounted directly on table with flange screwed to table plate. Accessory No brackets used. (All measurements in mm) TM 02
15 System 75 Chemical Resistant (CR) Table mounted (TM) Mounting Options Table Mounted Option with Table Bracket Dimensions (All measurements in mm) With table bracket System 75 Extraction Arm mounted on table side with a table bracket. Very functional option when impossible to mount directly on table or when a mobile installation is required. Accessory Table bracket, Part No.: TM 03
16 System 75 Chemical Resistant (CR) Table mounted (TM) Table bracket Technical Description Part No.: Dimensions (All measurements in mm) Used to mount system 75 Table Mounted Arms on table side. Removable for mobile installations. Made of white polyester powder coated steel. Other colours available on request. TM 04
17 System 75 Chemical Resistant (CR) Table mounted (TM) Spare Parts (A) (B) (C) (D) (E) (F) (G) Spare Parts List see next page 9 TM 05
18 System 75 Chemical Resistant (CR) Table mounted (TM) Spare Parts List Pos. Product No. Red White Joints A led B led C led D led E led F led G led Pos. Part No. Description A B C D E F G *) Spare Parts List for Joint with Damper see General Information When ordering spare parts please quote: Product No. eg.: (white) Description - B-pipe 550 Part No Quantity - 1 pc. [pieces applied] /-5 C-pipe TM Spring 4 mm (2-joint) Spring 4 mm Spring 5 mm O-ring /-5 B-pipe /-5 B-pipe /-5 B-pipe /-5 B-pipe Threaded Stay Thumbscrew, 5 mm Teflon Washer /-5 A-pipe /-5 A-pipe /-5 A-pipe /-5 A-pipe /-5 Joint with Damper* /-5 Joint 5 mm If you wish to customize the arm with a spare part which is not a constituent part of the particular model, please contact your Alsident dealer. TM 06
19 System 75 Chemical Resistant (CR) Table mounted (TM) Mounting Instruction With internal spring TM BM 07 7
20 System 75 Chemical Resistant (CR) Wall Mounted (WM) Working Area Wall Mounted with Extractor tube Note: A: Model R: 795 mm B: Model R: 1200 mm C: Model R: 1060 mm D: Model R: 1230mm E: Model R: 1550 mm F: Model R: 1660 mm G: Model R: 1990 mm The working area of the arm is defined from the center of the opening of the accessory. The working area changes according to type of accessory and positioning. When choosing the arm we recommend that the stationary working position of the accessory is not placed in the highest or lowest part of the working area. (All measurements in mm) Accessory: Extractor tube No WM 01
21 System 75 Chemical Resistant (CR) Wall Mounted (WM) Mounting Options Wall Mounted Option Dimensions (All measurements in mm) Wall Mounted System 75 Extraction Arm wall mounted with Wall Bracket. Accessory: Wall bracket, Part No.: WM 02
22 System 75 Chemical Resistant (CR) Wall Mounted (WM) Wall bracket Technical Description Artikelnr.: Part No.: and und Dimensions (All measurements in mm) Used for System 75 Wall mounted Extraction Arms. Made of steel with a white polyester powdercoating on all surfaces Other colours and acid-proof stainless steel (AISI 316L) available on request. Colour Open sides Closed sides White WM 03
23 System 75 Chemical Resistant (CR) Wall Mounted (WM) Spare Parts (A) (B) (C) (D) (E) (F) (H) b a 2b a Spare Parts List see next page WM 04
24 System 75 Chemical Resistant (CR) Wall Mounted (WM) Spare Parts List Pos. Product No. Red White Joints A led B led C led D led E led F led G led Pos. Part No. Description A B C D E F G /-5 C-pipe CM Spring WM/CM 4 mm Spring WM/CM 5 mm Spring WM/CM 6 mm 1 2a Gas Spring 100N (Push) 1 2b Gas Spring 150N (Pull) O-ring /-5 B-pipe /-5 B-pipe /-5 B-pipe /-5 B-pipe /-5 B-pipe a Angle for joint B Threaded Stay Thumbscrew Teflon Washer /-5 A-pipe /-5 A-pipe /-5 A-pipe /-5 A-pipe /-5 A-pipe 900 gas spring /-5 Joint with Damper* Ring for gas spring Reinforcement ring 1 1 *) Spare Parts List for joint with Damper see General information When ordering spare parts please quote: Product No. eg.: (white) Description - A-pipe 350 Part No Quantity - 1 pc. [pieces applied] If you wish to customize the arm with a spare part which is not a constituent part of the particular model, please contact your Alsident dealer. WM 05
25 System 75 Chemical Resistant (CR) Wall Mounted (WM) Mounting Instruction With internal spring WM 06
26 System 75 Chemical Resistant (CR) Wall Mounted (WM) Mounting Instruction With gas spring WM 07
27 System 75 Chemical Resistant (CR) Ceiling Mounted (CM) Working Area Ceiling Mounted with Extractor tube Note: A: Model R: 795 mm B: Model R: 1220mm C: Model R: 1060 mm D: Model R: 1230 mm E: Model R: 1550 mm F: Model R: 1660 mm G: Model R: 1990 mm Accessory: Extractor tube nr The working area of the arm is defined from the center of the opening of the accessory. The working area changes according to type of accessory and positioning. When choosing the arm we recommend that the stationary working position of the accessory is not placed in the highest or lowest part of the working area. (All measurements in mm) CM01
28 System 75 Chemical Resistant (CR) Ceiling Mounted (CM) Mounting Options Ceiling Mounted Option Dimensions (All measurements in mm) Ceiling Mounted System 75 Extraction Arm ceiling munted with ceiling column with side connection. Accessory Ceiling Column, Part No. depending on lengths. CM02
29 System 75 Chemical Resistant (CR) Ceiling Mounted (CM) Ceiling Column Technical Description Ceiling columns Used for mounting the System 75 Ceiling Mounted Extraction Arms. The ceiling column is made of steel with a white polyester powder coating. Available in two models with side connection or top connection to duct. For standard lengths see below. Other lengths, colours or acidproof stainless steel (AISI 316L) available on request. Connection diameter With side connection: 80 mm With top connection: max.100 mm Length [mm] Weight app. [kg] Top connection Side connection Dimensions (All measurements in mm) CM03
30 System 75 Chemical Resistant (CR) Ceiling Mounted (CM) Spare Parts (A) (B) (C) (D) (E) (F) (H) b a 2b a Spare Parts List see next page CM04
31 System 75 Chemical Resistant (CR) Ceiling Mounted (CM) Spare Parts List Pos. Product No. Red White Joints A led B led C led D led E led F led G led Pos. Part No. Description A B C D E F G /-5 C-pipe CM Spring WM/CM 4 mm Spring WM/CM 5 mm Spring WM/CM 6 mm 1 2a Gas Spring 100N (Push) 1 2b Gas Spring 150N (Pull) O-ring /-5 B-pipe /-5 B-pipe /-5 B-pipe /-5 B-pipe /-5 B-pipe a Angle for joint B Threaded Stay Thumbscrew Teflon Washer /-5 A-pipe /-5 A-pipe /-5 A-pipe /-5 A-pipe /-5 A-pipe 900 gas spring /-5 Joint with Damper* Ring for gas spring Reinforcement ring 1 1 *) Spare Parts List for joint with Damper see General information When ordering spare parts please quote: Product No. eg.: (white) Description - A-pipe 350 Part No Quantity - 1 pc. [pieces applied] If you wish to customize the arm with a spare part which is not a constituent part of the particular model, please contact your Alsident dealer. CM05
32 System 75 Chemical Resistant (CR) Ceiling Mounted (CM) Mounting Instruction With internal spring CM06
33 System 75 Chemical Resistant (CR) Ceiling Mounted (CM) Mounting Instruction With gas spring CM07
SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR
Alsident System 100 Chemical Resistant (CR) Product Information System 100 Chemical Resistant (CR) General Information Product Specification Product Description System 100 Chemical Resistant (CR) Alsident
More informationSYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information
Alsident System100 Aluminium (AL) Product Information System 100 Aluminium (AL) General Information Product Specification Product Description System 100 Aluminium Alsident System airflow between 140-400
More informationAlsident System 50 Flex
Alsident System 50 Flex Aluminium (AL) Antistatic (AS) Product Information System 50 Flex General Information Product Specification Product Description System 50 Flex Aluminium/Antistatic The System 50
More informationALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm
ALSIDENT SYSTEM 75 Easily positioned all-round fume extraction arm Local Exhaust for a cleaner working environment Installation of individual fume extraction systems at the source of the pollutant during
More informationALSIDENT SYSTEM 50. A small flexible extraction arm
ALSIDENT SYSTEM 50 A small flexible extraction arm Local Exhaust for a cleaner working environment Installation of individual fume extraction systems at the source of the pollutant during the working process
More informationSYSTEM10. Airflow Alarm
ALSIDENT SYSTEM10 Airflow Alarm Securing optimal suction efficiency Easily and quickly installed even without expertise Installed directly on the suction arm Easily operated Fits all suction arms from
More informationManual Use and Maintenance ALSIDENT SYSTEM 75
Manual Use and Maintenance ALSIDENT SYSTEM 75 Use and maintenance ALSIDENT SYSTEM 75 System 75 is intended for air volumes between 80 and 180 m 3 /hour and available in the following mounting versions:
More informationFTM-TECHNOLOGIES : 78, rue Raymond Poincaré Nanterre FRANCE Tél Fax:
LOCL EXTRCTOR TERFU local extractor with friction joints for worksites where great flexibility is required. TERFU is a local extractor with friction joints designed for use in workplaces where great flexibility
More information4m. Extension arm. HVU Arm. ASX ATEX arm. HVU Arm
extension Arms 4m. Extension arm HVU Arm HVU Arm ASX ATEX arm 22 Wing arm WING ARM WING arm The classic point extraction arm. The WING-arm construction is more than 40 years old, but with small improvements
More informationExtraction arm FX100 Original
Bench top extraction systems for all environments. The Nederman bench top systems can be used in every type of environment, from assembly stations, where soldering fumes are extracted, to laboratories,
More informationLOCAL EXTRACTION Pure advantages. The ideal extractor for light industry and laboratory environments.
The ideal extractor for light industry and laboratory environments. With its optimal design, Ø 4 inch Movex ME has a very low pressure drop, which provides many valuable benefits. - Low pressure drop saves
More informationBench Top Extraction Arms
Bench Top Extraction Arms The Nederman BenchTop arms can be used in every type of environment, ranging from assembly stations, where solder fumes are extracted, to laboratories, where protection against
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for applications where small, flexible and easy-touse arms are required. Nederman FX2 arms are made of lightweight anodized aluminium sections, with three adjustable,
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationMini Arms 4" Diameter
Operation and Maintenance Manual Mini rms 4" Diameter MONOXIVENT - SOURCE CPTURE SYSTEMS - info@ Mini rms Installation of the Monoxivent extractor arm before beginning operation of ceiling, wall, or bench
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationSYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT
136 SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT Extraction kits for testing centres for cars, light commercial vehicles and heavy vehicles with manual or automatic return system Equipments
More informationUser Instruction SUPER-PM ATEX. Note! Before installation and use in application follow the instructions
User Instruction SUPER-PM ATEX Note! Before installation and use in application follow the instructions PLYMOTH-PLYMEX GmbH Zilzkreuz 14 53 604 Bad Honnef Tel.: 02224/98853-0 Fax: 02224/98853-22 e-mail:
More informationPA-S small filter. Technical Data G 1/8
PA-S small filter PA-S small filter G 1/8 Bowl material Polyamid Head material Polypropylene Gasket material Buna-N Filter material PE 5µm, 35µm or 80µm Temperature Min./Max. C 5-50 Maximum pressure bar
More informationPLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES
PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES TECHNICAL CHARACTERISTICS PP30 OVERVIEW : The PP 30F (rear connection) and PP 31F (lateral connection) are employed for the diffusion of air using
More informationExhaust Extraction Systems for Stationary Vehicles
Exhaust Extraction Systems for Stationary Vehicles The systems presented in this section are used for extracting exhaust from parked vehicles. All solutions offer simple installation and optimal extraction
More informationProduct manual Extraction arm KUA
Product manual Extraction arm KUA Table of contents: Page: Technical description...2 Delivery...2 Advantages...2 Technical data...2 Components and operation...2 Handling...2 Hood operation...2 Mounting
More informationFume Extraction. 150 Fume Extraction
150 Fume Extraction 100 % Air cleaning Zero-Smog The Weller Zero-Smog Systems put an end to air pollution caused by solder - ing, adhesives and laser work. In all of these applications fumes or fine particles
More informationDental Art presents Alchemist
Innovative design, state of the art materials, eye for detail, attention to safety and hygiene, made in Italy. All this, together with our commitment to meet clients requirements - supporting them at all
More informationBall-bearing KUA. A superflexible extractor for small and medium sized work places
Ball-bearing KUA A superflexible extractor for small and medium sized work places Copyright. All rights reserved. PLYMOVENT AB Föreningsgatan 37, SE-211 52 Malmö, Sweden Tel: +46 40 30 31 30, Fax: +46
More informationFILTER MODULES FILTER MODULES APPLICATIONS
FILTER MODULES FILTER MODULES APPLICATIONS MF MF filter modules were developed for use as filtration systems in centralised systems or individual work stations for the extraction of welding fumes. They
More informationFume cupboard systems
69 DATA SHEETS Fume cupboard systems Bench-mounted fume cupboard (DS) 10 11 GENERAL INFRMATIN Fundamental safety and performance targets The DELTAguard bench-mounted fume cupboard is designed in such a
More informationFilterBox Wall. Automatically or manually cleaned for dust & fume applications.
Automatically or manually cleaned for dust & fume applications. FilterBox Wall can come with or without a attached. The models without a are suitable for installations with an external and contactor, and
More informationDHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser
DHL HEPA terminal filter diffuser Low turbulent flow diffuser (LTF), also suitable for exhaust Installation flush to the ceiling, also suitable for wall installation A measurement access through the diffuser
More informationCV-Series. Single Curve Conveyors
CV-Series Single Curve Conveyors J O I N T H E Q U I E T R E V O L U T I O N I N C O N V E Y O R T E C H N O L O G Y V-Series Engineered to have the tightest turning radius in the industry. Built for nearly
More informationFume cupboards and extraction devices
Fume cupboards and extraction devices Energy efficiency, maximum ergonomics and a larger internal workspace make working with our new fume cupboards even safer and more convenient. A new design together
More informationGTK 80. Technical data
Industrial square suspension system with open cable duct for heavy loads Modular construction with free accessible cable duct Floor, top-mounting or wall exit options Technical data Material: connecting
More informationPortable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration
AQC source capture equipment March 27, 2008 version. Leaflet under construction. More information to come at a later date. Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500
More informationDuctless mobile fume hoods with modular filtration column
Ductless mobile fume hoods with modular filtration column Designed to protect users during applications emitting vapors and/or chemical particles, the Captair Flex line offers a level of performance that
More informationProduct manual Extraction arm KUA
Product manual Extraction arm KUA Table of contents: Page: Technical description...2 Delivery...2 Area of use...2 Technical data...2 Components and operation...2 Working radius...3 Pressure loss...3 Mounting
More informationELADOS EMP III Diaphragm Pump type
ELADOS EMP III Diaphragm Pump type 00160-00540 Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal
More informationELADOS EMP III Diaphragm Pump type electronically controlled
electronically controlled Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal and low level warning
More informationExhaust rail system 920 for stationary vehicles
Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several
More informationProduct manual Junior LM-2
Product manual Junior LM-2 Table of contents: Page: Technical description... 2 Delivery... 2 Advantages... 2 Technical data... 2 Construction and function... 2 Handling... 2 Hood operation... 2 Mounting
More informationFume Arms. AQC source capture equipment. Superior technology generating substantial operating savings. No internal adjustment
AQC source capture equipment Fume Arms No internal adjustment Smooth tubes, low static pressure Air volume damper included Self-locking joints 2 grab handles for arm positioning Hood diverter increases
More informationTECbox SYSTEM. Six families of boxes made of six different materials, to give the best solution to every application
TECbox SYSTEM Six families of boxes made of six different materials, to give the best solution to every application or environment. The materials used are ABS, POLYCARBONATE, POLYESTER, STEEL, STAINLESS
More informationVersion with operating bar
Midi-Heki 1/8 25.1 Content.DOC Midi-Heki Art. 1368 Art. 1369 Art. 1370 Content Version with operating bar Version with crank Elektrical version Ordering Details Technical Drawing Spare Parts Glazing Dome
More informationSMART Application Structure Acoustics s n fa f o o R
Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature +60 C, and dustiness not exceeding 0,3 g/m³, without viscous,
More informationKH E, KH E
INSTRUCTIONS FOR USE Kitchen extractor hood Type: KH 17101 E, KH 17106 E Dear Customer!! You are now a user of the newest generation kitchen extractor hood of KH 17101, KH 17106. This hood has been designed
More informationEXPERTISE IN PLASTICS JERRYCANS
EXPERTISE IN PLASTICS JERRYCANS Contents Jerrycans Volume litres Neck Material Colour * Page opti-rib 2 / 2,5 / 3 DIN 45 HDPE natural colour 5 opti-rib 5 DIN 45 HDPE natural colour 6 opti-rib 5 DIN 50
More informationELADOS EMP III Diaphragm Pump type
ELADOS EMP III Diaphragm Pump type 00800-01200 Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal
More informationDATA SHEETS. Fume cupboard systems Walk-in fume cupboard (DB)
69 DATA SHEETS Fume cupboard systems Walk-in fume cupboard (DB) 28 29 GENERAL INFRMATIN Fundamental safety and performance targets The walk-in fume cupboard is designed in such a way that hazardous airborne
More informationEnergy Supply Systems
Energy Supply Systems MULTIPOLE CONDUCTOR RAIL 831 10-125 amps KAT0831-0001b-E 13 pole multipole conductor rail in 33 package distribution centres of the postal service (Post AG) 9 pole multipole conductor
More informationExhaust rail system 920 for stationary vehicles
Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several
More informationFume-A-Vent Motorized Hose Reel
Fume-A-Vent Motorized Hose Reel Date 7/12 Part No.HRM XX-XX-XX Hose Reels TAB 3-C-1 Shown Above: Fume-A-Vent Model HRM-2-0620 Motor Hose Reel with 5" x 20' Series 2 600 Rubber impregnated Polyester Hose.
More informationMaximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment
Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...
More informationMultipole Conductor Rail MultiLine Program 0831
Multipole Conductor Rail MultiLine Program 0831 Contents Description / Technical Data Description....2 Technical Data....3 Conductor Rails Rails complete with pre-mounted Connector...4 Power Feeds....5
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationOperating instructions
Operating instructions Type TEKA filtoo TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72 E-Mail:
More informationFume Arms. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. No internal adjustment
Diversified Air Systems, Inc. Fume Arms No internal adjustment Smooth tubes, low static pressure Air volume damper included Self-locking joints 2 grab handles for arm positioning Hood diverter increases
More informationBenchTop Extraction Arm FX2 100 Original
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationORION. Safety Class 2 100% exhaust. ALMOST Rocket Science
LaboGene SCANdinavian by design. ORION ALMOST Rocket Science Safety Class 2 100% exhaust Probably the best Class 2 with 100% exhaust for work with animal handling or high concentrations of organic solvents
More informationSnap-on mini-columns and accessories (Export range)
Direct cliping 87045 LIMOGES Cedex Phone : +33 (0) 5 55 06 87 87 Fax : +33 (0) 5 55 06 88 88 CONTENTS Pages 1. Description & Composition... 1 2. Installation... 1 3. Dimensions... 2 4. Technical characteristics
More informationVolume Extraction Extraction Units
Volume Extraction Extraction Units WFE 2S WFE 2 Kit 1 WFE 2 Kit 2 WFE 2S small, portable, quiet with electronic speed control, for centralised applications. The Weller WFE 2S extraction unit purifies the
More informationFILTER Pure advantage. A flexible modular filter for particles and gas
A flexible modular filter for particles and gas The MOVEX modular filter CV with its sturdy profile allows the possibility to satisfy the need of several functions in one product. The filter in its basic
More informationELADOS EMP IV E00 Diaphragm Pump type
ELADOS EMP IV E00 Diaphragm Pump type 01400 02100 Single phase motor with winding protection, standard Plastic external housing, metal internal housing High delivery capacity at low number of strokes Safety
More informationPressure relief dampers
X X testregistrierung Pressure relief dampers Type Closed blade For the prevention of excess pressure in rooms Pressure relief dampers for gas fire extinguishing systems and transformer substations Air
More informationDuct filter units. Duct HEPA filter units AKF
Duct HEPA filter units AKF Application Duct HEPA filter unit AKF is being used in the network of inlet and outlet ducts used to supply or extract air from the rooms with highest demands regarding air cleanness.
More informationGloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.
GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE. GloveFAST Cyto Pharma/Aseptic Faster Isolator for Cytotoxic and Sterility test THE USER-FRIENDLY PRACTICAL
More informationYOUR WISH IS OUR COMMAND. Junction boxes. Catalogue-Junction boxes
YOUR WISH IS OUR COMMAND Junction boxes Catalogue-Junction boxes 04 Index Index Hard rubber junction boxes Technical notes Type 1010 Type 1212 Type 1616 Type 1812 Type 2516 Type 1010- Type 2516 Pages 4-8
More informationMultileaf damper with actuator
JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings
More informationAir Curtains for Revolving Doors
Air Curtains for Revolving Doors Air curtains for revolving doors ROTOWIND The design of buildings with revolving doors that integrate with the environment is a common solution when the entrance has adverse
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationINSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60
INSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60 Dear Customer You are now a user of a kitchen extractor hood of ZRW type. This hood has been designed and manufactured specially with
More informationDry Ice Blasting Unit
ASCOJET 2001RX Dry Ice Blasting Unit complete (fully adjustable) part no. 900368 The ASCOJET 2001RX is a compact, mobile dry ice bla- sting unit featuring a very powerful double hose system. The ASCOJET
More informationPRICE LIST 08/2008. GROSS prices in L19. Validity: August 1 December 31, 2008
PRICE LIST 08/2008 GROSS prices in Validity: August 1 December 31, 2008 L19 How to use this price list The price list is divided in the following chapters: Extraction arms and hoses Stationary units Portable
More informationCBI JET SERIES. Corrosive. Backward. Inclined. Special Design for: ! Research Centers. ! Laboratory Hood Exhaust. ! Industrial Fume Exhaust
CBI JET SERIES Corrosive Backward Inclined Special Design for:! Research Centers! Laboratory Hood Exhaust! Industrial Fume Exhaust! Waste Water Treatment! Roof or Duct Mounted CBI JET Series Characteristics
More informationSUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130
SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities
More informationLeading the way for clean air in the new millennium. S o u r c e C a p t u r e
Leading the way for clean air in the new millennium. S o u r c e C a p t u r e Market Driven Product Solutions Driven by technological innovations and responsive customer service, Airflow Systems, Inc.
More informationKNIFE GATE VALVES -- MODEL A
PRODUCT DESCRIPTION Wafer style, uni-directional knife gate valve. One piece integral cast body with guides to support the gate and seating wedges. High flow rates with low pressure drops. Several seat
More informationABOUT KJN ALUMINIUM PROFILES
P R O D U C T C ATA L O G U E ABOUT KJN ALUMINIUM PROFILES Our range of Aluminum Profile is available in a large range of sizes starting with 20 x 20 through to 100 x 200 making it suitable to use in all
More informationExcelair. Every filter is created to perfection!
Excelair. Every filter is created to perfection! Since1982 HEPA FILTERS Filters are engineered & constructed for providing ultra clean air to protect clean rooms, pharmaceutical companies, hospitals, food
More informationKENYA MARINE AND FISHERIES RESEARCH INSTITUTE
KENYA MARINE AND FISHERIES RESEARCH INSTITUTE TEL: +254 020 8021560/1, 0712003853, 0770244932; FAX: +254 020 2353226Email: director@kmfri.co.ke When replying please quote KMF/HQs/TENDER/15/2017-2018/VOL.I/
More informationGloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.
GloveFAST Cyto/Aseptic Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE. GloveFAST Cyto/Aseptic Faster Isolator for Cytotoxic and Sterility test COMMON FEATURES CONSTRUCTION Full body of the unit and
More informationB-250PD B-300PD B-500PD B-700PD B-800PD B-900PD
ITEM : 71100 ISSUED: APRIL 19, 1993 REVISED: APRIL 26, 2001 HOSHIZAKI STORAGE BIN MODEL B-250PD B-300PD B-500PD B-700PD B-800PD B-900PD PARTS LIST B-250PD G-0 May, 1997 H-0 Dec., 1997 J-0 March, 1999 K-0
More informationActuated Valves PRICING
Electric & Pneumatic Actuated Valves Actuated Valves PRICING Page Suitable for Oil-Free air handling to 5 psi, not for distribution of compressed air or gas Spears Manufacturing Company Due to Material
More informationCompleting Your Fume Removal System
Once a laboratory hood has been selected, the next step is to select the proper blower and ductwork. It is important that these be sized correctly depending on hood size, application, CFM, and distance
More informationEnergy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)
Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units
More informationS ST-SeriesBrochure_modified:STSeriesBrochure.qxd2/4/20091:32PMPage17 ST- T Series Straight Conveyors -Series your Material Handling Specialist
ST-Series ST-SeriesBrochure_modified:ST Series Brochure.qxd 2/4/2009 1:32 PM Page 17 ST-Series Straight Conveyors your Material Handling Specialist ST-SeriesBrochure_modified:ST Series Brochure.qxd 2/4/2009
More informationGrilles & Diffusers. Series NV Non-vision grilles. Incorporating. Sight blocking design ensures privacy is maintained
Grilles & Diffusers Incorporating Series NV Sight blocking design ensures privacy is maintained Perfect for areas like changing rooms Four models available including units to suit door mounting and dark
More informationELADOS EMP II Diaphragm Pump Type V
ELADOS EMP II Diaphragm Pump Type V3014-00240 Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse storage Standard signal drive Empty signal report
More informationPneumatic Metering Pump II 3 12 l/h
Works without electrical current Mechanical stroke adjustment Space-saving design Separate air bleeding High reliability due to teflon compound diaphragm Optional with integrated solenoid valve Pneumatic
More informationJ L I e x h a u s t h o o d
JLI exhaust hood PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air 7 Pressure loss & Sound data, Lights 8 We want
More informationKAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System
25-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / CONTENTS E-LINE / General 2-3 System 4 Technical Characteristics 5 Standard Busbars 6 Standard Elements 7 Tap Off Plugs 8 Standard
More informationA X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S
A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S Australia s leading fan company PRODUCT OVERVIEW COMMERCIAL INDUSTRIAL POWER & ENERGY MINING FOOD PROCESSING
More informationTechnical Information
Technical Information Materials ISO- Code Material Colour Operating Temperature PA Polyamide Light grey PP PP-EL natural PP PVDF PVDF-EL PFA PTFE PTFE-EL PEEK Polypropylene Polypropylene Polypropylene
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 PERFORMANCE CHART A (up to 0.6 kw) 203 PERFORMANCE CHART A (from 0.75 kw up to 1.1 kw) 204 PERFORMANCE CHART A (1.3 kw) 205 PERFORMANCE
More informationDry Ice Blasting Unit
Dry Ice Blasting Unit ASCOJET 1208 complete (fully adjustable) part no. 900960 The ASCOJET 1208 features a new modern frame design and self-explanatory pictogram. This powerful blasting machine is very
More informationVOLUME CONTROL / REGULATING DAMPERS
VOLUME CONTROL / REGULATING S PRODUCT RANGE Model Range Includes A - Multi-Leaf. (Flanged - Rectangular Duct) B - Multi-Leaf. (Slip joint / Spigot - Rectangular Duct) C - Multi-Leaf. (Slip joint / Spigot
More informationApplicazioni Tecniche
SAFETY SPRAY SHIELDS FOR FLANGES Our plastic cloth safety shields are manufactured from single and multilayered clear cloth for easy visibility or a colored cloth with a leak indicating patch. Weep holes
More informationUM SERIES VENTILATION GRILLES OVERVIEW AND TECHNICAL DATA
VENTILATION GRILLES OVERVIEW AND TECHNICAL DATA CHARACTERISTICS : series ventilation grilles are completely adjustable air terminal devices with swinging blades which can be regulated one by one. These
More informationCOLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationBROEN-LAB UNIFLEX FITTINGS FOR SPECIAL WATER
BROEN-LAB UNIFLEX FITTINGS FOR SPECIAL WATER LAB TABLE OF CONTENTS Content Page Table of Content 2 BROEN-LAB UniFlex TM BASIC 4 Product Overview 5 Special Water Fittings Wall Mounted Fitting - Fully Recirculating...
More informationFilter Hood Model CA-S
Model CA-S Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety,
More information