FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

Size: px
Start display at page:

Download "FilterBox Wall. Automatically or manually cleaned for dust & fume applications."

Transcription

1 Automatically or manually cleaned for dust & fume applications. FilterBox Wall can come with or without a attached. The models without a are suitable for installations with an external and contactor, and can be used with multiple FilterBox units. The unit is delivered with a wall bracket for easy installation. Depending on the model, the filter cartridge is either manually or automatically cleaned. For the manual model, there is an alarm indicating when the air flow is too low, and an operating hours meter. The model with automatic has an advanced filter control system that starts the process automatically when the air flow is too low. Additional protection from harmful particles given if a HEPA filter is installed. For dust applications, the unit is cleaned mechanically. For welding fumes it uses a combination of mechanical and compressed air. For welding applications, compressed air is required. Note! FilterBox is not for use in environments where combustible dust or gases are present, and it is not for use in filtering combustible dust or gases. User friendly and superior filter, mechanical and/or with compressed air for long filter life Automatic damper preventing dust from leaking out while Dust free filter replacement and emptying of dust bin Third party approval for welding fumes category W according to EN 2- Third pparty approval for welding fumes category W according to EN 2- Product name Noise level (db(a)) Filter efficiency (%) 99 FilterBox Wall (without ) 66 (N24 ) 74 (N27 ) Compressed air requirement DIN ISO 857-, class 5/5/4 (7 bar) Installation Material Dustbin volume (l) 5 Indoor Extraction arm diameter (mm) Airflow (m/h) 00 Filter Area (m2) Arm length (m) Filter type Number of filter elements Filter material Electric plug Casing in rotomoulded plastic Without Cartridge Polyester PW Without

2 Filter method Mechanical, Compressed air

3 FilterBox Wall Image Description Power Voltage (V) Frequency (Hz) No of phases Weight (kg) Power (kw) Note Model 2626*,5 2646* 2656* with ** with 26826**,5 with 26896**,5 with ** 26506* 2656* 2686* 2696* 2606* 266* 266*

4 Image Description Power Voltage (V) Frequency (Hz) No of phases Weight (kg) Power (kw) Note Model * 2676* with N with N Not with sensor clamp *** with N Not with sensor clamp *** with N with N , with N with N with N with N with N * ** with ***Not with sensor clamp

5 Accessory Part No Outlet with duct connection D=200mm Sensor clamp to be attached to the earth cable of the welding power source Filter-PW-FB Filter-PW HE-FB Filter PWA-FB HEPA filter H4 0m2 Filterbox HEPA filter H 0m2 Filterbox Bags for Filterbox dust bin, 0pcs Twin Module blue

6 FilterBox Wall with N24 included FilterBox Wall with N29 included

7 FilterBox wall without

LCP Cartridge Dust Collector

LCP Cartridge Dust Collector Cartridge collectors designed for continuous operation in process and general extraction applications with free flowing. LCP cartridge collectors designed for continuous operation in process and general

More information

FilterMax F. Modular dust collector with integrated pre-separator

FilterMax F. Modular dust collector with integrated pre-separator Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator the FilterMax F is ideal for applications with

More information

FilterMax F. Modular dust collector with integrated pre-separator

FilterMax F. Modular dust collector with integrated pre-separator Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator the FilterMax F is ideal for applications with

More information

FlexPAK 800 DX. The leading extraction solution. Always the right capacity.

FlexPAK 800 DX. The leading extraction solution. Always the right capacity. The leading extraction solution. Always the right capacity. The FlexPAK DX high vacuum unit represents the foremost solution on the market. The unit is designed for the extraction of welding fumes, grinding

More information

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax DF. Modular dust multi purpose collector. Models Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive

More information

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax DF. Modular dust multi purpose collector. Models Technical leaflet 988009 10 1 Date 2009-10-26 FilterMax DF Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the

More information

FilterMax F. Modular dust collector with integrated pre-separator. Models

FilterMax F. Modular dust collector with integrated pre-separator. Models Technical leaflet 988010 10 1 Date 2009-11-02 FilterMax F Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator

More information

Exhaust rail system 920 for stationary vehicles

Exhaust rail system 920 for stationary vehicles Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several

More information

Exhaust rail system 920 for stationary vehicles

Exhaust rail system 920 for stationary vehicles Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several

More information

FMKZ casette filter, EX

FMKZ casette filter, EX Modular cassette dust collector, built for continuous use in industrial process filtration and dust collection applications The FMK25 range is a reverse jet cassette dust collector. It was built for continuous

More information

Extraction arm FX100 Original

Extraction arm FX100 Original Bench top extraction systems for all environments. The Nederman bench top systems can be used in every type of environment, from assembly stations, where soldering fumes are extracted, to laboratories,

More information

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

NCF fans 60Hz. Protection class IP 55

NCF fans 60Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

Bench Top Extraction Arms

Bench Top Extraction Arms Bench Top Extraction Arms The Nederman BenchTop arms can be used in every type of environment, ranging from assembly stations, where solder fumes are extracted, to laboratories, where protection against

More information

NCF 60 Hz. Protection class IP 55

NCF 60 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

Pneumatic Rail System (PRS)

Pneumatic Rail System (PRS) Exhaust extraction system for emergency stations Pneumatic Rail System PRS, is a fully automatic, high capacity exhaust extraction system for up to 4 emergency vehicles per bay. The system is based on

More information

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust. VARIO VARIO Separation of fine dust particles The VARIO series is particularly suitable for separation of fine dust. The VARIO units are of modular construction in order to meet different requirements,

More information

FilterMax DF. Modular dust multi purpose collector

FilterMax DF. Modular dust multi purpose collector Modular dust multi purpose collector FilterMax DF is an efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive

More information

About Dustcontrol Filter Units

About Dustcontrol Filter Units An extraction system should always be equipped with a filter unit. The filter unit separates coarse material in the cyclone body of the unit and fine dust in an internal arrangement of conical pleated

More information

About Vacuum Producers

About Vacuum Producers Vacuum Producers About Vacuum Producers The heart of the system The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. In Dustcontrol extraction systems,

More information

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC. we make clean air Air Filtration Solutions Industrial Commercial Residential Che mic al F ilte r HE PA Filt er Filter Although very effective against very fine particles, filters do not filter out gasses

More information

LCP Cartridge Dust Collector

LCP Cartridge Dust Collector Cartridge collectors designed for continuous operation in process and general extraction applications with free flowing. LCP cartridge collectors designed for continuous operation in process and general

More information

A new dimension ZPF 9H the central suction and filter unit

A new dimension ZPF 9H the central suction and filter unit A new dimension ZPF 9H the central suction and filter unit BGIA-certified central suction and filter systems Universal and certified TEKA pioneer for BGIA-certification of central suction and filter units.

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17 Genset with manual control panel. Image for guidance purposes. ENGINE ALTERNATOR MAKE KOHLER MAKE MODEL KDI3404TM MODEL CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) STAND-BY POWER: (LTP Limited

More information

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 The best and most cost-efficient solution for applications where small, flexible and easy-touse arms are required. Nederman FX2 arms are made of lightweight anodized aluminium sections, with three adjustable,

More information

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight

More information

FILTER Pure advantage. A flexible modular filter for particles and gas

FILTER Pure advantage. A flexible modular filter for particles and gas A flexible modular filter for particles and gas The MOVEX modular filter CV with its sturdy profile allows the possibility to satisfy the need of several functions in one product. The filter in its basic

More information

LCP Cartridge Dust Collector

LCP Cartridge Dust Collector Cartridge collectors designed for continuous operation in process and general extraction applications with free flowing. LCP cartridge collectors designed for continuous operation in process and general

More information

Improving your workspace

Improving your workspace FILTERMAX DF FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive dust from other industries.

More information

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight

More information

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight

More information

series 260 LAS 260 HD FK

series 260 LAS 260 HD FK series 260 Date of issue: 11/2013 Extraction. Filtration. Persistence. Use and application The is suitable for collecting and filtering dry and non-combustible types of dust contained in non-explosive

More information

THE INTELIAIR TM. i2m AND i3m FUME EXTRACTION ARMS KEY FEATURES

THE INTELIAIR TM. i2m AND i3m FUME EXTRACTION ARMS KEY FEATURES THE INTELIAIR TM i2m AND i3m FUME EXTRACTION ARMS THE INTELLIGENT AIR CONTROL SYSTEM The Inteliair I2M and I3M self-supporting fume extraction arms are designed to deliver quality and performance whilst

More information

SF-1000 workbench - welding table. User s Manual.

SF-1000 workbench - welding table. User s Manual. SF-1000 workbench - welding table User s Manual - 2 - SF-1000 workbench About this document 3 Graphic symbols 3 Equipment arrival 4 Product application 4 Construction 4 Technical data and dimension 5 Arm

More information

Weld filter C10. Weld filter C20. Easy to move and position. Includes 3 m long extraction arm, Original. Cleanable filter with high filtration

Weld filter C10. Weld filter C20. Easy to move and position. Includes 3 m long extraction arm, Original. Cleanable filter with high filtration Weld filters C0 and C0 Mobile extraction/filter units The obile Weld units C0 and C0 are used for the extraction and filtration of lighter welding fues. Weld filter C0 Easy to ove and position. Includes

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B Test Equipment Depot - 800.7.84-99 Washington Street Melrose, MA 076 TestEquipmentDepot.com BTX-08 Fume Extraction System System User Guide For Your Safety... Items Supplied... Description... Installation...

More information

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration -MC -MC Diversified Air Systems, Inc. pantone 2756 Portable filtration unit / 650 CFM (305 L/s) pantone 2756 Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration 99.9% efficiency

More information

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 30 kva STAND-BY POWER: 33 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE ALTERNATOR

More information

DESKTOP CONTAINMENT SYSTEM

DESKTOP CONTAINMENT SYSTEM AIR TECHNOLOGIES INC. BRATIN LE OF EX CE G CE Solder and Waxing Fumes Conformal Coating Vapors Reflow Oven Exhaust Wave Soldering Exhaust Dedrossing Solvent Vapors Laser Cutting & Marking CELLE 1991-2

More information

Weller Info No. 2. New in Weller Volume Extraction System WFE2ES

Weller Info No. 2. New in Weller Volume Extraction System WFE2ES July 2007 www.cooperhandtools.com/weller New in 2007 Weller Volume Extraction System WFE2ES Weller Info No. 2 New for 2007: Weller Volume Fume Extraction System WFE2ES Our testing conclusively proves that

More information

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing Soldering/Desoldering Convection Rework Fume Extraction Fluid Dispensing www.beasuperproducer.com BVX-100 Benchtop Single User Arm/Plenum System Portable, single user fume extraction system Low noise unit

More information

2007 /

2007 / Product Catalogue Produktkatalog Каталог продукции компании Catalogue des produits Termékkatalógus Catalog de produse Katalog výrobků Catálogo de productos Katalog produktów Catálogo de Produtos Productcatalogus

More information

Products that improve the working environment, reduce environmental impact and increase efficiency.

Products that improve the working environment, reduce environmental impact and increase efficiency. Products that improve the working environment, reduce environmental impact and increase efficiency. Welcome to Nederman! This is our new product catalogue with our standard products. We hope it will act

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model: IIV85 Generator set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE IVECO MODEL N45TM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1)

More information

Fume extractor is warranted for two years, parts and labor.

Fume extractor is warranted for two years, parts and labor. Industrial Centralized Systems Issued Feb. 7 Index No. AY/. Welding Safety and Health Quick Specs Industrial Applications Manufacturing and fabrication Schools and training centers Processes Stick (SMAW)

More information

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07 Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 20 kva STANDBY POWER: 22 kva PRP Prime Power norma ISO 85281 LTP Limited Time Power norma ISO 85281 ENGINE ALTERNATOR

More information

quatroair.com AIR TECHNOLOGIES INC.

quatroair.com AIR TECHNOLOGIES INC. quatroair.com AIR TECHNOLOGIES INC. LaserBlue Gel Zero Filter Bypass. Guaranteed! Designed to meet the most stringent cleanroom requirements, the LaserBlue gel forms an impenetrable barrier against the

More information

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury

More information

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

Cartridge filter SDFC

Cartridge filter SDFC Cartridge filter SDFC General Information: Dust collector type SDFC is a compressed air cleaned cartridge filter for continuous filtration of fine dust. The filter has a built in fan with a capacity of

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42 TECHNICAL SPECIFICATIONS Model: II-044 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL F32SM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 40

More information

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 130 kva STAND-BY POWER: 145 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE

More information

PRODUCT GUIDE Version 2004:02 For a better workbench environment

PRODUCT GUIDE Version 2004:02 For a better workbench environment PRODUCT GUIDE Version 2004:02 For a better workbench environment FILTRONIC AB Box 2284, SE-531 02 LIDKÖPING SWEDEN Tel +46 (0)510-208 10, Fax +46 (0)510-201 40 e-mail: office@filtronic.se www.filtronic.se

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12 TECHNICAL SPECIFICATIONS Model: ID-095 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE DEUTZ MODEL BF4M 1013 E CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 85

More information

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44 Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 150 kva STAND-BY POWER: 165 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE

More information

Product catalogue 2010

Product catalogue 2010 Product catalogue 2010 welding, cutting and more... www.kemper.eu BG-PRÜFZERT BGIA Gefahrstoff geprüft Schweißrauchklasse W3 Mobile filter units Selection criteria for mobile filter equipment... 49-50

More information

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration AQC source capture equipment March 27, 2008 version. Leaflet under construction. More information to come at a later date. Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500

More information

1 / Genset general description

1 / Genset general description Measures: L : 1350 mm H : 1200 mm W: 720 mm H Weight: 410 kg W L Hz 50Hz V 400/230V Water cooled Diesel 1500 r.p.m. Open Illustrative image. CE Conformity 1 / Genset general description Engine KOHLER KDW

More information

1 / Genset general description

1 / Genset general description Measures: L : 3450 mm H : 2140 mm W: 1250 mm Weight: 4147 kg W L H Hz 50 Hz Water cooled 1500 r.p.m V 400/230 V Diesel Open skid CE Conformity illustrative image 1 / Genset general description Engine Alternator

More information

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853 BULL 240 EBS INDUSTRIAL VACUUM Operator s Manual VAC.BULL240.EBS SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853 P 800.522.2606 F 865.745.4110 SASECompany.com SAFETY INSTRUCTIONS Operators

More information

Fume Extraction & Dust Collection

Fume Extraction & Dust Collection 1.877.632.4118 mepbrothers.com 725 Century St. Winnipeg, MB. R3H 0M2 Fume Extraction & Dust Collection Shaker Dust Collectors Maxiply Economical pocket type dust collector with manual shaker cleaning (95

More information

5 Compact Vacuum Systems. Compact Vacuum Systems

5 Compact Vacuum Systems. Compact Vacuum Systems Compact Vacuum Systems Compact Vacuum Systems 7 Compact Vacuum Systems DC 11-Module The DC 11-Module is a complete central unit for source extraction and industrial cleaning. The unit can manage just about

More information

1 / Genset general description

1 / Genset general description Measures: L : 3950 mm H : 2400 mm W: 1550 mm H Weight: 4600kg W L Hz 50 Hz V 400/230 V Water cooled Diesel 1500 r.p.m Open skid Illustrative image. CE Conformity 1 / Genset general description Engine Alternator

More information

The future of wet and dry vacuum cleaning

The future of wet and dry vacuum cleaning VL500 is ideally suited for hotels, contract cleaners, education, exhibition and conference centers as well as public buildings, manufacturing and industrial applications. A failsafe filter design makes

More information

FILTER MODULES FILTER MODULES APPLICATIONS

FILTER MODULES FILTER MODULES APPLICATIONS FILTER MODULES FILTER MODULES APPLICATIONS MF MF filter modules were developed for use as filtration systems in centralised systems or individual work stations for the extraction of welding fumes. They

More information

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust 2 BERNER INTERNATIONAL Claire total At a glance CLAIRE TOTAL PRO CHEMISTRY Protection Shield The multiple award-winning Shield

More information

FlowFAST H. Horizontal Laminar Flow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

FlowFAST H. Horizontal Laminar Flow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. PROTECTION, SAFETY, RELIABILITY. AND MORE. BEYOND MINIMUM SAFETY REQUIREMENT FlowFAST H Cabinets are ISO Class 3 horizontal laminar flow cabinets which represent far more economical and valid alternatives

More information

Duct filter units. Duct HEPA filter units AKF

Duct filter units. Duct HEPA filter units AKF Duct HEPA filter units AKF Application Duct HEPA filter unit AKF is being used in the network of inlet and outlet ducts used to supply or extract air from the rooms with highest demands regarding air cleanness.

More information

APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM

APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM The Technology Center of DuPage is seeking bids for thirty (30) welding booths with fume exhaust system as described below. Companies or individuals

More information

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4 Automatic with amf/ats panel Stand-by Genset V2. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 250 kva STAND-BY POWER: 275 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO

More information

(ULT300-UM.x-HFM050) Technical Documentation

(ULT300-UM.x-HFM050) Technical Documentation LAS300.x-01 (ULT300-UM.x-HFM050) Technical Documentation Date of issue: 08 / 2010 clean air, strong performance LAS-series, modular air extraction and filtration units for Air handling equipment for environmental

More information

100L. 942 mm. 335 mm 385 mm

100L. 942 mm. 335 mm 385 mm 1/5 Altea 60L Altea 100L Altea 60L pedal Body and pedal colour Lid and pedal base colour 100L 60L (pedal) 60L Easy Empty Avalilable colour for plastic bags "Slim-Fit" 942 mm 995 mm 910 mm OUTDOOR INDOOR

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32 TECHNICAL SPECIFICATIONS Model: IV-500 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE VOLVO MODEL TAD 1345 GE CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1)

More information

Product catalogue 2010

Product catalogue 2010 Product catalogue 2010 welding, cutting and more... www.kemper.eu KEMPER Filter-Cell KEMPER Filter-Cell... 85 KEMPER Filter-Cell XL... 86 Accessories and spare parts... 87 84 KEMPER Filter-Cell The KEMPER

More information

Compact Vacuum Systems

Compact Vacuum Systems Compact Vacuum Systems 6 Compact Vacuum Systems DC 11-Module The DC 11-Module is a complete central unit for source extraction and industrial cleaning. The unit can manage just about every kind of dust

More information

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:

More information

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier Airistar 100GT Owner s Manual 2007 Airistar 100GT Air Purifier 100 GT Check power switches. Both the green on-off switch and the speed control knob must be in the on position. Check that the unit is connected

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

Modular filter system for effective removal of oil mist

Modular filter system for effective removal of oil mist MistEliminator Modular filter system for effective removal of oil mist Do you control oil mist? MistEliminator We do. Oil mist or oil smoke arise when metalworking fluids are used to either cool metal

More information

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up. Measures: L : 1500 mm H : 1275 mm W: 800 mm H Weight: 550 Kg W L Hz 50 Hz V 230 V Water cooled Diesel illustrative image. 1500 r.p.m Opened CE Conformity 1 / Genset general decription Engine Alternator

More information

TFS 1000 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY

TFS 1000 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY www.tbh.eu PEOPLE / ENVIRONMENT / MACHINERY // TRIPLE PROTECTION APPLICATION is the result of thorough development. It is used for laser marking and

More information

V. Aa. Gram A/S

V. Aa. Gram A/S Compact compressed-air cleaned filter unit with timer control for filtration of welding smoke, grinding dust, cutting smoke and dusty air containing metal, rock, plastic etc. or from handling various powder

More information

Operating instructions

Operating instructions Operating instructions Type TEKA filtoo TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72 E-Mail:

More information

Novenco Tunnel Fans. Novax October 2007

Novenco Tunnel Fans. Novax October 2007 Novenco Tunnel Fans Novax October 2007 Product facts Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC and AUR) and

More information

Eurovacuum EVC Series

Eurovacuum EVC Series Eurovacuum EVC Series Dry Running Claw Vacuum Pump Eurovacuum EVC Series Dry Running Claw Vacuum Pumps Eurovacuum Company is offering its various products to meet industrial vacuum needs. Eurovacuum Company

More information

Products, systems and solutions for improved workplaces 2009/2010

Products, systems and solutions for improved workplaces 2009/2010 Products, systems and solutions for improved workplaces 2009/2010 Bringing good conditions to workplaces and the environment For more than 60 years Nederman has developed products and solutions to reduce

More information

RESPIRATORY CATALOG. The SR 500. PAPR family. The AirPlus. PAPR family

RESPIRATORY CATALOG. The SR 500. PAPR family. The AirPlus. PAPR family RESPIRATORY CATALOG 2018 The SR 500 PAPR family prevents pollutants, gases, vapors & particulates from penetrating the breathing zone. The AirPlus PAPR family also supplies fresh filtered air, keeping

More information

(ULT200-UM.x-HFM050) Technical Documentation

(ULT200-UM.x-HFM050) Technical Documentation SRA200.x-01 (ULT200-UM.x-HFM050) Technical Documentation Date of issue: 07 / 2010 clean air, strong performance SRA-series, modular air extraction and filtration units for Air handling equipment for environmental

More information

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9 Automatic without ats panel Standby Genset V3. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 10 kva STANDBY POWER: 11 kva PRP Prime Power norma ISO 85281 LTP Limited Time Power norma ISO 85281

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

V. Aa. Gram A/S

V. Aa. Gram A/S Energy-optimized unit for larger filtration tasks. Is used for filtration of welding smoke, grinding dust, cutting smoke and dusty air containing metal, rocks, plastic etc. or from handling various powder

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4 TECHNICAL SPECIFICATIONS Model: II-190 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL NEF N67 TM4 CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 170

More information

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS The Complete Plug-and-Play Solution WE KNOW FILTRATION Donaldson is a global provider of filtration solutions for manufacturing industries. Our advanced technology,

More information

Fume Extraction. 22 o C DIGITAL RANGE. 250 m 3 / hr BROCHURE

Fume Extraction. 22 o C DIGITAL RANGE. 250 m 3 / hr BROCHURE Fume Extraction DIGITAL RANGE 20 m 3 / hr 20 22 o C The Future of Fume Extraction... BROCHURE Contents Information Filters Introduction 3 Pre - Filters 19-20 Digital Control System - Main Filters 21-22

More information

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure PRO100-2 (EUIIIa Compliant) 50/60 Hz Switchable Rating Prime Product 100 kva / 80 kwe KEY FEATURES Rental Ready Features Forklift pockets Fully certified single point lifting eye Integrated heavy duty

More information

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure PRO275-2 (EUIIIa Compliant) 50/60Hz Switchable Rating Prime Product 275 kva / 220 kwe KEY FEATURES Rental Ready Features Forklift pockets Fully certified dual point lifting Integrated heavy duty drag bar

More information

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR 13 POWERBOX EC FANS - ESTOC EC FEATURES Sizes from 3 to 3 mm diameter Air flow up to.1 m 3 /s Static pressures up to Pa Controllable EC motors Multiple outlet orientations ELECTRICAL SUPPLY 22-2V/Hz/1f

More information

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up. Measures: L: 1300 mm W: 750 mm H: 1160 mm H Weight: W L 257 Kg Hz 50 Hz V 230 V Water cooled illustrative image. 1500 r.p.m Opened 1 / Genset general decription CE Conformity GENERAL TECHNICAL DATA Engine

More information