DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Size: px
Start display at page:

Download "DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up."

Transcription

1 Measures: L : 1500 mm H : 1275 mm W: 800 mm H Weight: 550 Kg W L Hz 50 Hz V 230 V Water cooled Diesel illustrative image r.p.m Opened CE Conformity 1 / Genset general decription Engine Alternator STAMFORD PI 144H > Open genset with automatic start-up, control card allows automatic, manual or signal start-up. GENERAL TECHNICAL DATA Performance class Frequency Voltage G2 50Hz 230 V Control panel DSE 6020 Fuel tank (L) 160 POWER 1 PRP (kva / KW) 20 / 16 ESP (kva / KW) 22 / 17,6 Voltage PRP (KVA/KW) ESP (KVA/KW) Amperage (A) /16 22/17, PRP: Continuous power ( Prime Power ) ISO standard. ESP: Emergency power ( Emergency Standby Power ) ISO standard.

2 2 /Engine specifications Engine general data Manufacturer / Model r.p.m Max. Power ESP (kva) 22,3 Power PRP (kva) 20,3 Fuel Diesel Number of cylinders 4 > diesel engine, inline 4-cylinders, 4-stroke, natural suction, mechanically regulated power through fuel pump. Complying TIER 0 and EU Stage 0 emissions. Engine capacity 2200 Compression ratio 23,3:1 Cooling system Regulation type Engine type / injection / suction type Liquid Mechanic Diesel / indirect / natural Fuel Fuel type Diesel Fuel tank capacity (L) / Fuel feed system > Indirect injection system, filter that prevents the passage of particles, original parts from the engine manufacturer. Fuel consumption table % Load Consumption PRP Consumption ESP L/h Autonomy (h) L/h Autonomy (h) 50% 2,9 55,2 3,3 48,5 75% ,6 34,8 100% 5,3 30,2 6,1 26,2 Cooling system Fan airflow (m 3 /min) 29,4 Fan power consumption (kw) 0,125 Engine + radiator capacity (L) / Cooling system > Cooling by fully distributed coolant in a closed circuit driven by a pump activated by the engine. Tropicalized radiator. Original parts from the engine manufacturer. Lubrication system Total oil capacity (L) 10,6 2.3 / Lubrication system > Lubrication system driven by the crankshaft driven pump. Filter on top with full flow cartridge inserted, front crankcase. Original parts from the engine manufacturer. Air intake system Combustion air flow (m³/min) 1, / Air intake system > Natural air intake system including twostage filter. Original parts from the engine manufacturer.

3 Electrical start system Number of batteries 1 Battery features 12V 60Ah Starting voltage (V) 12V 2.5 / Start system > Start system by electric motor, battery (without maintenance) with disconnector and charging alternator driven by the starter motor (1,1kW, 12V), original parts from the engine manufacturer. Exhaust system Exhaust gas flow (m³/min) 2,7 Exhaust gas temperature (ºC) / Exhaust system > Attenuation level -15dB(A). Complying TIER 0 and EU Stage 0 emissions. Exhaust external diameter (mm) 42 Max. exhaust backpressure (kpa) 10,2 3 / Alternator specifications Alternator General Data Manufacturer/model STAMFORD PI 144H No. poles 4 Insulation class H number of wires 12 Mechanical protection degree IP23 Voltage regulator AVR AS480 Voltage regulator ±1% ESP power rating 27ºC (kva) 24,9 PRP power rating 40ºC (kva) 22,7 number of phases 1 Power factor (cos φ) 1 Efficiency at 100% Load η (%) 85,2 Efficiency at 110% Load η (%) 84,8 Low wave distortion: > Alternator STAMFORD 4-poles, brushless, robust mechanical structure with easy access to connections and components, insulation class H, 12-wires, winding with 2/3 pitch and autoexcited AVR. Protection with Premium epoxy resins, high voltage parts are impregnated under vacuum allowing always an excellent insulation. The alternator complies with the following standards: - AS IEC BS EN VDE BS CAN/CSA-C NEMA MG THD (100% load) = 2% - THF < 2% - Complying with EN , EN standards on radio interference.

4 4 / Bench specifications Genset mounted over an electro-welded bench made of high-strength steel, painted with electrostatic epoxy polyester powder paint. Union assembly to the bench by anti-vibration shock absorbers. Fuel tank located on the bench, provided with measuring gauge and fuel installation to the engine. Tested in saline mist chamber according to the ASTM B , 500h resistance. 5 / Control panel Including protection devices, distribution with DSE 6020 control card, that allows to operate in automatic, manual or by signal starting modes. 5.1 / Main elements of the control panel: - EMERGENCY STOP BUTTON. - DEEP SEA BATTERY CHARGER: Designed to be permanently connected to the battery and keep 100% of the load. The charger switches to float mode when the load is complete. - PROTECTIONS: 4-pole magnetothermic protection against overloads and shortcircuits. Protection fuses for the control assembly. Interruptor protección Marca/Modelo Schneider Easypact CVS100B + TM-G 100 4P 5.2 / Control card DSE 6020 DEEP SEA control card, with mains grid monitor. The genset will automatically start up when detecting a fault in the electric power network and it will turn off automatically as well, when the electrical supply is re-established. It can also work in manual mode and by signal. It allows you to monitor a wide range of generator parameters and display information alerts, status and alarms. The module includes USB communication ports, 4 configurable digital inputs, 3 analog inputs, 6 configurable outputs, emergency stop button, 8-35 V battery charger. It has 132x64p illuminated LCD display with 4 lines of text, 5-key navigation through menus, programmable clocks and alarms, reading and displaying parameter values, including RMS values. > The control card complies with the following environmental tests: - BS EN (electromagnetic compatibility) - BS EN (electromagnetic compatibility) - BS EN (electrical safety) - BS EN (Temperature) - BS EN (Vibration) - BS EN (Humidity) - BS EN (Shock) The entire module is easily configurable via PC using the DSE specific software configuration. Different operating modes: AUTOMATIC mode, MANUAL mode, SIGNAL mode and TEST mode. Other alternative configurations are available upon request to extend the capabilities of the operation modes.

5 Menu navigations Main status an instrumentation display Alarm indicator Transfer to mains (Manual mode only) Transfer to generator (Manual model only) Start engine (manual mode only) Stop genset Mute alarm Manual mode Test on load mode Select Auto mode / Allowing reading Engine Mains Alarm detected Turning speed Mains Voltage (L-N) Start-up failure Low fuel level Oil pressure Mains Voltage (L-L) High coolant temperature High/Low generator frequency Battery Voltage Mains Frequency Low oil pressure Overload Hours counter Over/low speed engine Charging alternator failure Coolant temperature High/low generator voltage Maintenance interval External emergency stop Generator Voltage generator (L-N) Generator frequency Power factor Voltage generator (L-L) Generator intensity Generator load (kw, kva, kwh, kvah) > Genset reponse to a fully configurable alarm via DSE software.

6 5.3 / ATS The genset can be provided with an automatic transfer, as an optional device Investor table IV poles (A) 10 kva 25 > The table below shows the different amperage rating of the magneto thermal switches and investors cabinets. 15 kva kva kva kva kva 100 GENSET POWER 65 kva kva kva kva kva kva kva kva kva 800 Regulations ENVIRONMENTAL CONDITIONS ISO :2005 standard: 25ºC, 100kPa and 30% relative humidity: PRIME POWER (PRP): Electrical power data available at variable load for unlimited hours per year. A 10% overload is permissible for 1 hour every 12 hours according to ISO :2005. EMERGENCY STANDBY POWER (ESP): Electrical power data available at variable load in an emergency according to ISO :2005. The DAGARTECH genset has CE marking which includes the following directives: /42 Machinery safety /95/CE Electrical Safety /95/CE Electromagnetic compatibility /88/CE Noise emissions in the environment outdoors

1 / Genset general description

1 / Genset general description Measures: L : 3450 mm H : 2140 mm W: 1250 mm Weight: 4147 kg W L H Hz 50 Hz Water cooled 1500 r.p.m V 400/230 V Diesel Open skid CE Conformity illustrative image 1 / Genset general description Engine Alternator

More information

1 / Genset general description

1 / Genset general description Measures: L : 1350 mm H : 1200 mm W: 720 mm H Weight: 410 kg W L Hz 50Hz V 400/230V Water cooled Diesel 1500 r.p.m. Open Illustrative image. CE Conformity 1 / Genset general description Engine KOHLER KDW

More information

1 / Genset general description

1 / Genset general description Measures: L : 3950 mm H : 2400 mm W: 1550 mm H Weight: 4600kg W L Hz 50 Hz V 400/230 V Water cooled Diesel 1500 r.p.m Open skid Illustrative image. CE Conformity 1 / Genset general description Engine Alternator

More information

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up. Measures: L: 1300 mm W: 750 mm H: 1160 mm H Weight: W L 257 Kg Hz 50 Hz V 230 V Water cooled illustrative image. 1500 r.p.m Opened 1 / Genset general decription CE Conformity GENERAL TECHNICAL DATA Engine

More information

Technical specification

Technical specification Technical specification Stand-by Generator Sets TECHNICAL INFORMATION Standby Power KVA 2500 (ESP) KW 2180 Prime Power KVA 2281 (PRP) KW 1975 Mechanical structure Open skid on base frame Engine CUMMINS

More information

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9 Automatic without ats panel Standby Genset V3. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 10 kva STANDBY POWER: 11 kva PRP Prime Power norma ISO 85281 LTP Limited Time Power norma ISO 85281

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12 TECHNICAL SPECIFICATIONS Model: ID-095 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE DEUTZ MODEL BF4M 1013 E CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 85

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4 TECHNICAL SPECIFICATIONS Model: II-190 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL NEF N67 TM4 CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 170

More information

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4 Automatic with amf/ats panel Stand-by Genset V2. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 250 kva STAND-BY POWER: 275 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO

More information

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 130 kva STAND-BY POWER: 145 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE

More information

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44 Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 150 kva STAND-BY POWER: 165 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE

More information

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 30 kva STAND-BY POWER: 33 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE ALTERNATOR

More information

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001 WATER-COOLED THREE PHASE 50 HZ DIESEL Generating Rates SERVICE Power Power Rated Speed Standard Voltage Available Voltages Rated at power factor PRP STANDBY kva 1549 1660 kw r.p.m. 1239 1328 1.500 V 400/230

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32 TECHNICAL SPECIFICATIONS Model: IV-500 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE VOLVO MODEL TAD 1345 GE CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1)

More information

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07 Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 20 kva STANDBY POWER: 22 kva PRP Prime Power norma ISO 85281 LTP Limited Time Power norma ISO 85281 ENGINE ALTERNATOR

More information

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized RATINGS 400 V - 50 Hz Standby kva 3500 KWe 2800 Prime kva 3182 KWe 2546 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,

More information

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power LSC500S3 Powered by Cummins 50HZ Water-cooled Three Phase Diesel Model LSC500S3 Standby Power KVA 500 KW 400 Prime Power KVA 450 KW 360 Frequency Hz 50 Voltage V 230/400 Rated speed rpm 1500 Cummins has

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22 TECHNICAL SPECIFICATIONS Model: IVRN-115 Image for guidance purposes. (400 / 230 V) ENGINE ALTERNATOR MAKE VOLVO MODEL MODEL TAD551GE (IIIA) MECC-ALTE ECP 34-2S / 4 CONTINUOUS POWER: (PRP Prime Power norma

More information

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1 A10 WATER-COOLED SINGLE PHASE 50 HZ NON REQUIRED 97/68 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m. 1.500 Standard Voltage V 240 Rated at power factor

More information

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0. 350 KW / 438 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000kW. Through our commitment to

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS ELECTRICAL FREQUENCY VOLTAGE PRIME STAND BY 50Hz 3Ph 400/230v 34kVA / 27kW 37kVA / 30kW 50Hz 1Ph 230V 26kVA / 26kW 28kVA / 28kW 60Hz 380/220v 37.5kVA / 30kW

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model: IIV85 Generator set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE IVECO MODEL N45TM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1)

More information

APD-ULJ250. Standby Power

APD-ULJ250. Standby Power AKSA Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main production

More information

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized RATINGS 400 V - 50 Hz Standby kva 3300 KWe 2640 Prime kva 3000 KWe 2400 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,

More information

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP) Standby Power: Standby power is defined as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering

More information

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified RATINGS 480 V - 60 Hz Standby kva 1562.50 KWe 1250 Prime kva 1420 KWe 1136 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator

More information

70 KW / 90 KVA POWERED by

70 KW / 90 KVA POWERED by 70 KW / 90 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized RATINGS 480 V - 60 Hz Standby kva 2187.50 KWe 1750 Prime kva 1989 KWe 1591 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator

More information

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GMN - 22P Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 21.50 Standby power LTP kw 17.20 Prime power PRP kva 20.10 Prime power

More information

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW500DO Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 508.23 Standby power LTP kw 406.58 Prime power PRP kva 460.11 Prime

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17 Genset with manual control panel. Image for guidance purposes. ENGINE ALTERNATOR MAKE KOHLER MAKE MODEL KDI3404TM MODEL CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) STAND-BY POWER: (LTP Limited

More information

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized RATINGS 400 V - 50 Hz Standby kva 2250 KWe 1800 Prime kva 2045 KWe 1636 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,

More information

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me WGP-C30/S CUMMINS Series Rotate speed governor: Mechanical governor Excitation system: Self excited, SHUNT A.V.R model: AS480 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed

More information

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER MODEL: ERP-500S (PERKINS 2506A-E15TAG2) 1.500 R.P.M. 50 Hz TECHNICAL SPECIFICATIONS ENGINE MAKE MODEL CONTINUOUS POWER PRP norma ISO 8528-1 PERKINS 2206A-E15TAG2 STAND-BY POWER LTP norma ISO 8528-1 500

More information

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized RATINGS 400 V - 50 Hz Standby kva 1100 KWe 880 Prime kva 1000 KWe 800 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,

More information

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GMS-015Y Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 14.50 Standby power LTP kw 11.60 Prime power PRP kva 13.88 Prime power

More information

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A MODEL: ERD-100 (DEUTZ BF4M 1013 ECG2 ) 1.500 R.P.M. 50 Hz TECHNICAL SPECIFICATIONS ENGINE MAKE MODEL CONTINUOUS POWER PRP norma ISO 8528-1 DEUTZ BF4M 1013 ECG2 STAND-BY POWER LTP norma ISO 8528-1 ALTERNATOR

More information

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO D10 WATER-COOLED THREE PHASE 50 HZ NON COMPLYING 97/68/EC DIESEL Generating Rates SERVICE PRP STANDBY Power kva 83 89 Power kw 66 71 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages

More information

18 KW / 18 KVA POWERED by

18 KW / 18 KVA POWERED by 18 KW / 18 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42 TECHNICAL SPECIFICATIONS Model: II-044 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL F32SM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 40

More information

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA 20FT-HC WATER-COOLED THREE PHASE 50 HZ DIESEL Generating Rates SERVICE PRP STANDBY Power kva 1296 1420 Power kw 1037 1136 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 380/220-415/240

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS Powered by MTU G2300QX G2300X ELECTRICAL PRIME STAND BY Output Rating kva 2200 2360 kw 1760 1888 Frequency Hz 50 Rated Speed RPM 1500 Standard Voltage v 400/230

More information

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant RATINGS 400V - 50 Hz Standby kva 1650 KWe 1320 Prime kva 1500 KWe 1200 Benefits & features SDMO premium quality SDMO provides one source responsibility for the generating system and accessories The generator

More information

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC This generator set has been designed to meet ISO 8528 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 2000/14/EC 3 Phase

More information

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized RATINGS 400 V - 50 Hz Standby kva 2500 KWe 2000 Prime kva 2273 KWe 1818 Benefits & features SDMO premium quality SDMO provides one source responsibility for the generating system and accessories The generator

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized RATINGS 400 V - 50 Hz Standby kva 1100 KWe 880 Prime kva 1000 KWe 800 Benefits & features SDMO premium quality SDMO provides one source responsibility for the generating system and accessories The generator

More information

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power LSP88S3 Powered by 50HZ Water-cooled Three Phase Diesel Model LSP88S3 Standby Power KVA 88 KW 70 Prime Power KVA 80 KW 64 Frequency Hz 50 Voltage V 230/400 Rated speed rpm 1500 Perkins is one of the largest

More information

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 GSW22P Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 Power Rating Standby power LTP kva 13.80 Standby power LTP kw 13.80 Prime power PRP kva 13.50 Prime power

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO G1 WATER-COOLED THREE PHASE 50 HZ STAGE 2 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 350 390 Power kw 280 312 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 230-230/132

More information

DIESEL GENERATOR DATA SHEET

DIESEL GENERATOR DATA SHEET YANAN DIESEL GENERATOR Powered by MTU Model:YN3500MTU *Drawing above for illustration purposes only Ⅰ. GENERAL DATA Prime Power kw/kva 2540 3175 Standby Power kw/kva 2800 3500 Frequency Hz/rpm 60 1800

More information

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN E10 WATER-COOLED THREE PHASE 50 HZ STAGE 2 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 200 220 Power kw 160 176 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 230-230/132

More information

APD-NG400. NG Standby Power

APD-NG400. NG Standby Power AKSA Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main production

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power LSC220S3 Powered by Cummins 50HZ Water-cooled Three Phase Diesel Model LSC220S3 Standby Power KVA 220 KW 176 Prime Power KVA 200 KW 160 Frequency Hz 50 Voltage V 230/400 Rated speed rpm 1500 Cummins has

More information

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC This generator set has been designed to meet ISO 88 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 000//EC Phase Ratings,

More information

TPD2250H6.3 TECHNICAL DATA

TPD2250H6.3 TECHNICAL DATA TECHNICAL DATA DIESEL GENERATING SET TONTEK POWER LIMITED GREEN POWER SUPPLIER 50HZ www.tontekpower.com Page: 1/10 Specifications may change without Notice TPD2250H6.3 2250KVA/1800KW POWERED BY CUMMINS

More information

28 KW / 28 KVA POWERED by

28 KW / 28 KVA POWERED by 28 KW / 28 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3 GSL30D Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 32.50 Standby power LTP kw 26.00 Prime power PRP kva 30.50 Prime power

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

13,000 Watt Diesel Generator AGi13P E

13,000 Watt Diesel Generator AGi13P E GENERAL SPECIFICATIONS General Specifications Type Power Rating Standby Power Output Diesel Standby Generator 13,000 Watt (Standby) 12,000 Watt (Prime) 120 Volt @ 100 Amp 220 Volt @ 50 Amps Outputs 120

More information

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GMS - 560V Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 546.00 Standby power LTP kw 436.80 Prime power PRP kva 504.71 Prime

More information

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM

More information

45 KW / 55 KVA POWERED by

45 KW / 55 KVA POWERED by MODEL 45 KW / 55 KVA POWERED by Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford AKSA Power Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

80 KW / 100 KVA POWERED by

80 KW / 100 KVA POWERED by 80 KW / 100 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55 60 KW / 75 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0. 275 KW / 344 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

16 KW / 20 KVA POWERED by

16 KW / 20 KVA POWERED by 16 KW / 20 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A. AKSA Power Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main

More information

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A AKSA Power Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

10,000 Watt Diesel Generator AGi9P E

10,000 Watt Diesel Generator AGi9P E GENERAL SPECIFICATIONS General Specifications Type Power Rating Standby Power Output Diesel Standby Generator 10,000 Watt (Standby) 9,000 Watt (Prime) 120 Volt @ 80 Amp 240 Volt @ 40 Amp Outputs 120 Volt

More information

30 KW / 40 KVA POWERED by

30 KW / 40 KVA POWERED by 30 KW / 40 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

WPS60/S EP Series. Features:

WPS60/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life

More information

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR K2 WATER-COOLED THREE PHASE 50 HZ STAGE 3A DIESEL Generating Rates SERVICE PRP STANDBY Power kva 20 22 Power kw 16 17,6 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 230-230/132

More information

Standby Amper VOLTAGE

Standby Amper VOLTAGE INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and

More information

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH Prime* Voltage kva kw kva 380-415 180 144 200 Standby* kw 160 Ampere 251 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model

More information

1000 KW / 1250 KVA POWERED by

1000 KW / 1250 KVA POWERED by 1000 KW / 1250 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS G2000QX G2000X Powered by MITSUBISHI ELECTRICAL PRIME STAND BY Output Rating kva 1892 2035 kw 1514 1628 Frequency Hz 50 Rated Speed RPM 1500 Standard Voltage

More information

WPS100/S EP Series. Features:

WPS100/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

WPS20/S EP Series. Features:

WPS20/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

SIVASA Doosan Series. SD250 Technical Data

SIVASA Doosan Series. SD250 Technical Data Powered by Doosan P086TI 250KVA at 60Hz, 220V General feature: Assembled by Doosan diesel engine and Leroy Somer alternator. Three filters as standard, fuel and water separator as optional. Radiator and

More information

Rating Definitions and Conditions

Rating Definitions and Conditions Model Frequency/Speed Voltage Prime Power Standby Power MP13 S MP15@6 S 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230V/400V 277V/480V 12.5 KVA 10 KW 13.5 KVA 10.8 KW 15 KVA 12 KW 13.75 KVA 11

More information

WPS350/S EP Series. Features:

WPS350/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

55 KW / 70 KVA POWERED by

55 KW / 70 KVA POWERED by 55 KW / 70 KVA POWERED by MODEL TP-P55-T3-60-UL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our

More information

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/ General Characteristics Model Name AJD 33 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model JOHN DEERE 3029DF128 Alternator Made and Model ECP 28-VL/4 A Control Panel Model 7320 Canopy AK 20 Power

More information

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 660KVA Generator Set Specification NO: GKP660KVA2012 c 2012 The Generator King (Pty) Ltd. Ultra Silent,

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS G115QX G115X ELECTRICAL FREQUENCY VOLTAGE PRIME STAND BY 50Hz 3ph 400/230v 107.7kVA / 86.2kW 118.5kVA / 94.8kW 60Hz 3Ph 380/220v 102.0kVA / 81.6kW 111.9kVA

More information

Rental Power Kubota V2403 series engine

Rental Power Kubota V2403 series engine Specification sheet Rental Power Kubota V2403 series engine 20 kva 50 Hz Prime Description This Cummins commercial generator set is a fully integrated power generation system, providing optimum performance,

More information

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA K9 WATER-COOLED THREE PHASE 50 HZ NON COMPLYING 97/68/EC DIESEL Generating Rates SERVICE PRP STANDBY Power kva 400 450 Power kw 320 360 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages

More information

600 KW / 750 KVA POWERED by

600 KW / 750 KVA POWERED by 600 KW / 750 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

GE.VO.360/325.SS+0_all

GE.VO.360/325.SS+0_all . Generating Set Diesel +0_all Standard Equipment and features Canopy - Soundproofing Engine Soundproof canopy IP 32 monoblock Engine heater 230 V Polyester class1 soundproofing High coolant temperature

More information

204 KW / 254 KVA POWERED by

204 KW / 254 KVA POWERED by 204 KW / 254 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

WPS150/S EP Series. Features:

WPS150/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information