COMPANY INFORMATION CATEGORY INTRODUCTION //// PAGE 1

Size: px
Start display at page:

Download "COMPANY INFORMATION CATEGORY INTRODUCTION //// PAGE 1"

Transcription

1

2 * COMPANY INFORMATION PAGE 1 INTRODUCTION Dulhunty Power is a manufacturer and supplier of quality Electricity Transmission and Distribution products. The company has manufacturing plants in Sydney (Australia),Yangzhou (China) Bangkok (Thailand) and Darul Ehsan (Malaysia), as well as sales offices in New Zealand and Hong Kong. The company supplies its own products to utilities and contractors throughout Australia, New Zealand, China, and the Asia Pacific region. It also supplies components and fittings for a number of European and American companies involved in the electricity transmission and distribution sector. Dulhunty Power is most well known for its range of vibration control products and its technical capability in measuring and resolving vibration control problems in transmission line applications. The company has invested heavily in developing products and solutions for Aeolian vibration, and is one of the foremost companies in this field in the world. Apart from manufacturing and selling a large range of its own products, Dulhunty Power also represents a number of other manufacturers, supplying products including glass, porcelain and composite insulators, substation fittings, fault indicators, height meters, tension monitoring systems, switchgear, corona cameras, emergency tower structures, and high temperature conductors. Dulhunty Power arose from the merger of Dulhunty Industries Pty. Ltd., founded by industry veteran Mr Philip Dulhunty, Dulhunty Engineering Ltd., a Hong Kong-based company and Dulhunty Yangzhou Line Fittings Co. Ltd. (Philip Dulhunty was also the founder of Dulmison more then years ago). The merger combined the technical and marketing capacity of the Australian company with the low cost manufacturing of the Chinese company, and has opened new markets for both. In its first year of operations, the new Dulhunty Power has greatly expanded its horizons with sales from Australia to Finland and from Morocco to the USA.

3 CATALOGUE S INDEX A PAGE 2 Insulated systems Section A Page 3-21 Protective fittings Section B Page Line hardware Section C Page Helixon Section D Page Strain and suspension clamps Section E Page Fabricated fittings Section F Page Other products Section G Page Insulator pins Section H...Page Insulators Section I Page High Temperature Conductors Section J. Page Conductor information Section K Page Description index Page

4 INSULATED SYSTEMS INDEX A PAGE 3 LV ABC Suspension Clamp Type ABCSC. Page 4 Suspension Clamp and Rollers Type SO & ST... Page 5 LV ABC Tension Clamp Type ABCTC..Page 6 LV ABC Service Clamp Type ABCTCS...Page 7 LV ABC Bolted Service Clamp Type ABCTC..Page 8 Hook Bolt Type ABCHB. Page 9 Weak Link Type ABCWL..... Page 9 Hook Nut & Eye Nut Type ABCHN & ABCEN.. Page 10 Insulation Piercing Connectors Type ABCIPC....Page 11 Yoke Type ABCYB..... Page 12 Hook Brackets Type ABCHBR.. Page 13 Wedges Type ST & PMR.Page 14 HV ABC Termination Assembly Type.. Page 15 HV ABC Helixon Restraint Assembly Type HR Page 16 HV ABC Suspension Assembly Type SB & SHB Page 17 HV ABC Suspension Bracket & Hook Bolt Type SB & SHB Page 18 HV ABC Suspension Clamp Type ABCHV Page 19 HV ABC Roller and strap Type.. Page 20 CCT Conductor Fittings Type CCT.. Page 21

5 INSULATED SYSTEMS LV ABC SUSPENSION CLAMP A PAGE 4 The clamp is suitable for up to 30 line deviation. The clamp bush design is split for ease of application. Materials: Hardware: Galvanized steel Bush: EPDM Galv. Body ABCSC-435 Stainless Body ABCSC-435S Cable size sq AS Core 3 Core 4 Core 35 ABCSC-4 ABCSC-4S ABCSC-470 ABCSC-470S ABCSC-495 ABCSC-495S 95

6 INSULATED SYSTEMS SUSPENSION CLAMP & EXTENSION ROLLERS A PAGE 5 Used for the installation and suspension of the 4 core ABC cables from poles in straight lines and at angles of up to 90 Deg with 4x25 sq and 4x sq cables or up to 60 Deg with 4x95 sq cables. ST extension rollers are used during the installation when angles exceed 30 Degrees. Conductors sq Cable Dia Weight g Package pcs SO 99 4x(25-95) ST Extension rollers for SO

7 INSULATED SYSTEMS LV ABC TENSION CLAMP A PAGE 6 The strain clamps are designed to facilitate assembly onto the cable and includes spring loaded wedges and a wide area between the straps. The wedge action of the clamp ensures maximum holding strength. Materials: Wedges: Glass filled nylon Hardware: Galvanized Steel Straps: Aluminium ABCTC-2595 ABCTC-25 ABCTC-95 ABCTC-951 Cable Size sq AS x 2 x 95 4 x 25 4 x 4 x 4 x 95 4 x 95 4 x 1

8 INSULATED SYSTEMS LV ABC SERVICE CLAMP A PAGE 7 ABCTCS-235 Service clamp RC-3 Roller clamp These clamps are designed to facilitate service wire installation Materials: Glass filled nylon Straps: Stainless steel ABCTCS-435 Service clamp Description Service strain clamp Service strain clamp ABCTCS-435 ABCTCS-235 Cable Size sq AS and 4 core 6, 10,16 25 and 35 sq 2 core 6, 10,16 25 and 35 sq Roller clamp Roller clamp RC-3 RC-4 2 and 4 core 4, 6, 10 sq 4 core 16sq

9 INSULATED SYSTEMS LV ABC BOLTED CLAMP A PAGE 8 The bolted clamps are designed to facilitate installation of service wire terminations With its swivel blocks it can also be used as a suspension clamp. Materials: Glass filled nylon Straps: Stainless steel Strain arrangement Suspension arrangement Description Strain / Suspension clamp ABCTC Cable Size sq AS and 4 core 10, 16, 25 and 35 sq

10 INSULATED SYSTEMS HOOK BOLTS & WEAK LINKS A PAGE 9 Suitable for low voltage aerial bundled cables. Material: Galvanized Steel Suitable for low voltage aerial bundled cables. Minimum failing load : 4kN Length (L) 2 3 Diameter (D) 16 AS3766 ABCHB16-2 ABCHB16-3 Diameter (D) 20 AS3766 ABCHB20-2 ABCHB20-3 Material: Carbon Grade Galvanized Steel Diameter () Overall Length () Material Diameter () 4 ABCHB16-4 ABCHB20-4 ABCWL

11 INSULATED SYSTEMS HOOK NUTS & EYE NUTS AA PAGE 10 Material: Galvanized Steel Hook (dia.) AS3766 Failing Load kn AS3766 Thread Diameter AS3766 Thread Length AS3766 Eye (D) AS3766 Min. Failing Load kn ABCHN ABCEN ABCHN ABCEN-20 ABCEN ABCEN

12 INSULATED SYSTEMS LV ABC INSULATION PIERCING CONNECTORS AA PAGE 11 Insulated mains Cable sq Insulated branch Cable sq of Bolts ABCIPC to 95 2 to 6 1 ABCIPC to 95 6 to 35 1 ABCIPC to to 95 1 ABCIPC-446 to 1 to 1 2 Bare mains Alu Cable Diameter Insulated branch Cable sq of Bolts ABCIPC to to 35 1 ABCIPC to to 95 2 ABCIPC to 15.8 to 1 2

13 INSULATED SYSTEMS YOKES AA PAGE 12 The yoke bar is suitable for use with two of the ABCSC style clamps on angle poles, where the line angle deviates by more than 30 B Materials: Galvanized Steel A C A Dimension, B C Min. Failing Load kn AS3766 ABCYB ABCYB-12A

14 INSULATED SYSTEMS HOOK BRACKETS AA PAGE 13 The hook bracket can be fixed to concrete or steel poles with stainless steel strapping. A The hook bracket can be fixed to wooden poles with bolts or coach screws. Materials: Galvanized Steel P/N ABCHBR-12 (A) Hole Centers Diameter of Hook Min. Failing Load kn AS3766 ABCHBR-12L ABCHBR

15 INSULATED SYSTEMS WEDGES AA PAGE 14 Description Weight g Package Pcs ST 31 Two Plastic Wedges ST 192 One Plastic Wedge ST 200 Wooden Wedge During the installation of connectors the phase conductors of an insulated overhead cable can be separated by using wedges. The wedge can also be used when installing suspension clamps. The wedges can be left on the cable even after the installation Conductors Max Sq Weight g Package Pcs PMR 87 4 x PM x 25

16 INSULATED SYSTEMS HV ABC TYPICAL TERMINATION ASSEMBLY A PAGE 15 Alternative Hook Bracket or Eye Bolt Alternative Ball Hook or Ball Clevis Alternative Socket Thimble or Clevis Thimble Helixon deadend EB BC-70 CTHA-2600 Helixon deadend to suit catenary wire Part Metallic screened 7/ DE-S0600 Metallic screened 19/2.00.DE-S0975 Non metallic screened 7/ DE-A1430C Non metallic screened 19/3.65.DE-A17C ABCHBR-12 BH-70-LS SOCT-70 11kV Non Metallic Screened sq 22kV Non Metallic Screened sq HR35- HR70 35 & Helixon HVABC Restraint HR95 95 HR & 95 HR & 1 HR HR120-1L 120 & 1 HR185L 185

17 INSULATED SYSTEMS HV ABC HELIXON RESTRAINT A PAGE 16 Socket thimble Helixon deadend Helixon HVABC restraint HVABC cable 11kV Non Metallic Screened sq 22kV Non Metallic Screened sq The Helixon restraint is a preventative restraint designed to minimise bird caging Bird caging is caused by either gravity forces pulling on the conductor or as a result of a fault current. HR35- HR70 35 & Designs for Helixon restraints for metallic screened cables are available on request HR95 95 HR & 95 HR & 1 HR HR120-1L 120 & 1 HR185L 185

18 INSULATED SYSTEMS HV ABC TYPICAL SUSPENSION ASSEMBLY A PAGE 17 P/N SB10312 Suspension Bracket P/N SHB16200 Suspension Hook Bolt ABCHV Suspension clamp

19 INSULATED SYSTEMS HV ABC SUSPENSION BRACKET AND HOOK BOLT A PAGE 18 P/N SB10312 Suspension Bracket P/N SHB16200 Suspension Hook Bolt

20 INSULATED SYSTEMS HV ABC SUSPENSION CLAMP A PAGE 19 11kV Metallic Screened sq 22kV Metallic Screened sq 11kV Non Metallic Screened sq 22kV Non Metallic Screened sq ABCHVMSC ABCHVMSC- ABCHVMSC ABCHVMSC & 120 ABCHVMSC & 95 ABCHVMSC ABCHVMSC-1L 1 ABCHVMSC-185L ABCHVNMSC & This suspension clamp is suitable for use on High Voltage ABC cables. ABCHVNMSC-70 ABCHVNMSC-95 ABCHVNMSC & & 70 Whether the cables are metallic or non metallic Screened. It is suitable for up to 45 degree line deviation ABCHVNMSC & 120 ABCHVNMSC-1L 1 ABCHVNMSC-185L 185

21 INSULATED SYSTEMS HV ABC ROLLER A PAGE 20 The Dulhunty Power HVABC roller makes stringing HVABC easy. With its unique design and ease of handling, adjusting the sag and hanging the suspension clamps becomes simple With the additional yoke bar, most of the stringing angles can be accomplished CSR-YOKEBAR CSR-HVABC RACHETSTRAP Approx. Weight kg Approx. Weight kg CSR-HVABC 10.5 RATCHETSTRAP 1.3 CSR-YOKEBAR 3.5

22 INSULATED SYSTEMS CCT CONDUCTOR FITTINGS A PAGE 21 CCT post insulator 11kV long Part number CCT-145 CCT post insulator 11kV short Part number CCT-45 CCT strain insulator 11kV Part number CCT-STRAIN CCT Strain cover sq Part number CCT-COVER

23 LINE FITTINGS INDEX B PAGE 22 PROTECTIVE FITTINGS B Vibration Damper Type 4D. Page 23 Twin Spacer Type S2. Page 24 Twin Spacer-damper Type SD2.. Page 25 Triple Spacer-damper Type SD3.. Page 26 Quad Spacer-damper Type SD4.. Page 27 Six bundle spacer damper Type SD6.. Page 28 Spacer closing tool Type.. Page 29 Cast Bar Spacer Type CBS. Page 30 LINE HARDWARE C Anchor Shackle Type AS. Page 31 Ball Eye Link Type BEL...Page 32 Ball Clevis Type BC.Page 33 Clevis Tongue Type CT.Page 34 Twisted Clevis Tongue Type TCT. Page 35 Socket Clevis Extension Link Type SCEL Page 36 Ball Eye Extension Link Type BEEL Page 37 LINE HARDWARE C Chain Link Type CL. Page 38 Socket Clevis Type SC.Page 39 Socket Tongue Type ST. Page 40 Twisted Eye Tongue Type TET.. Page 41 Ball Hook Long Shank Type BH Page 42 Ball Hook Short Shank Type BH Page 43 Tongue Hook Type TH Page 44 Socket Thimble Type SOCT.. Page 45 Clevis Thimble Type CTH..Page 46 Aluminium Parallel Groove Clamps Type PGA..Page 47 Bimetal Parallel Groove Clamps Type PGB..Page 48 Copper Parallel Groove Clamps Type PGC. Page 49 Bimetal Service Clamps Type ASC. Page Bimetal Service Tee Type. Page 51 Ku-lugs Type KU.Page 52 Split Bolts Type SB. Page 53 Wire Rope Grips Type WRG Page 54 Gain Blocks Type GB Page 55 Compression deadends Type CDE. Page 56 &58 Compression midspan Type CMJ. Page 57 &59

24 PROTECTIVE FITTINGS VIBRATION DAMPER B PAGE 23 These fittings can be supplied to ANSI, IEC and AS Standards as requested Vibration dampers are used to absorb aeolian vibration of conductor, ground wire and OPGW on overhead transmission lines. Material: Weights - Galvanized cast iron Clamp - CP401 Aluminium alloy Nut and bolt - Galvanized steel / Stainless steel Messenger cable - Galvanized steel

25 PROTECTIVE FITTINGS TWIN SPACER B PAGE 24 Twin - Spacers are used to maintain conductor spacing and to restore conductor spacing after a short circuit occurs. Material: Body - Aluminium alloy Conductor bush - EPDM These fittings can be supplied to ANSI, IEC and AS Standards as requested Conductor Diameter Range. Dimensions, L Approx. Weight kg S ~ S ~ S ~ S ~ S ~ S2-0 14~ S ~

26 PROTECTIVE FITTINGS ARROW TWIN SPACER - DAMPERS B PAGE 25 Twin Spacer - Dampers are used to control aeolian vibration and conductor oscillation, maintain conductor spacing and restore conductor spacing after a short circuit occurs. Dulhunty "Arrow" spacer dampers always face up Material: Frame, arm and keeper - Aluminium alloy Nut and bolt - galvanized steel Damping Element- EPDM rubber These fittings can be supplied to ANSI, IEC and AS Standards as requested. Conductor Diameter Range. Dimensions, L Approx. Weight kg SD ~ SD2-4 18~ SD ~ SD2-0 18~ SD ~

27 PROTECTIVE FITTINGS ARROW TRIPLE SPACER - DAMPERS B PAGE 26 Triple Spacer - Dampers are used to control aeolian vibration and conductor oscillation, maintain conductor spacing and restore conductor spacing after a short circuit occurs. Dulhunty "Arrow" spacer dampers always face up Material: Frame, arm and keeper - Aluminium alloy Nut and bolt - galvanized steel Damping Element - EPDM rubber These fittings can be supplied to ANSI, IEC and AS Standards as requested. Conductor Diameter Range. Dimensions, L Approx. Weight kg SD ~ SD3-4 18~ SD ~ SD3-0 18~

28 PROTECTIVE FITTINGS ARROW QUAD SPACER - DAMPERS B PAGE 27 Quad Spacer - Dampers are used to control aeolian vibration and conductor oscillation, maintain conductor spacing and restore conductor spacing after a short circuit occurs. Dulhunty "Arrow" spacer dampers always face up Material: Frame, arm and keeper - Aluminium alloy Nut and bolt - Galvanized steel Damping Element - EPDM rubber These fittings can be supplied to ANSI, IEC and AS Standards as requested. Conductor Diameter Range. Dimensions, L Approx. Weight kg SD ~ SD4-4 18~ SD ~ SD4-0 18~

29 PROTECTIVE FITTINGS ARROW SIX BUNDLE SPACER - DAMPERS B PAGE 28 Six bundle spacer - Dampers are used to control aeolian vibration and conductor oscillation. Maintain conductor spacing and restore conductor spacing after a short circuit occurs. Dulhunty "Arrow" spacer dampers always face up Material: Frame, arm and keeper - Aluminium alloy Nut and bolt - Galvanized steel Damping Element - EPDM rubber Approx. Weight kg SD6:F1:762 11

30 PROTECTIVE FITTINGS SPACER CLOSING TOOL B PAGE 29 The quick and easy spacer closing tools are used with the QUICKLOCK arms on the spacer dampers. Material: Body Ductile iron SD6TOOL Approx. Weight kg 1.5

31 LINE HARDWARE CAST BAR SPACER C PAGE 30 Twin - Spacers are used to maintain conductor spacing and to restore conductor spacing after a short circuit occurs Material: Body Aluminium Hardware - Galvanized steel Conductor Diameter Range Spacer Length Approx. Weight kg CBS CBS CBS CBS Page 30

32 LINE HARDWARE ANCHOR SHACLE C PAGE 31 Minimum Failing load kn A Dimension, to AS : 2004 B C D E F Hole Bolt Diameter Approx. Weight Kg AS AS AS Material: Body - Galvanized steel Hardware - Galvanized steel Split pin - Stainless steel C F E A D B

33 LINE HARDWARE BALL EYE LINK C PAGE 32 Minimum Failing load kn Dimension, to AS : 2004 A B C Approx. Weight Kg BEL BEL BEL Material: Galvanized steel C The ball dimension is in accordance with AS : 2004 B A

34 LINE HARDWARE BALL CLEVIS C PAGE 33 Minimum Failing load kn A Dimension, to AS : 2004 B C D Ball F Hole Approx. Weight kg Material: Body - Galvanized steel Bolt and nut - Galvanized steel BC Split pin - stainless steel BC The ball dimension is in accordance with AS : 2004 BC A F B C D

35 LINE HARDWARE CLEVIS TONGUE C PAGE 34 D Material: Body - Galvanized steel Bolt and Nut - Galvanized steel Split pin - stainless steel C E A B Minimum Failing load kn A Dimension, to AS : 2004 B C D E φ Approx. Weight kg CT CT CT φ

36 LINE HARDWARE TWISTED CLEVIS TONGUE C PAGE 35 Material: Body - Galvanized steel Bolt and Nut - Galvanized steel Split pin - Stainless steel Minimum Failing load kn A B Dimension, D E S φh Approx. Weight kg TCT TCT TCT

37 LINE HARDWARE SOCKET CLEVIS EXTENSION LINK C PAGE 36 Material: Body - Galvanized forged steel Bolt and nut - Galvanized steel Split pin - stainless steel B G A The socket dimensions are in accordance with AS : 2004 F The SCEL can be supplied with either "W" type clips or "R" type clips C D E Minimum Failing load kn A Dimension, to AS : 2004 B C D E F G Max Approx. Weight kg SCEL

38 LINE HARDWARE BALL EYE EXTENSION LINK C PAGE 37 C A Material: Body - Galvanized forged steel The ball is in accordance with AS : 2004 D B E Minimum Failing load kn Ball Dimension, to AS : 2004 A B C D E Approx. Weight kg BEEL BEEL BEEL

39 LINE HARDWARE CHAIN LINK C PAGE 38 D Material: Galvanized steel B A C Minimum Failing load kn A Dimension, B C D Approx. Weight Kg CL CL CL

40 LINE HARDWARE SOCKET CLEVIS C PAGE 39 B C Material: Body - Galvanized forged steel Bolt and nut - Galvanized steel Split pin - Stainless steel The socket dimension is in accordance with AS : 2004 A E The SC can be supplied with either "W" type clips or "R" type clips. D Minimum Failing load kn Dimension, to AS : 2004 A B C D E Approx. Weight kg SC SC SC

41 LINE HARDWARE SOCKET TONGUE C PAGE 40 Material: Body - Galvanized forged steel B The socket dimension is in accordance with AS : 2004 The ST can be supplied with either "W" type clips or "R" type clips. C A STT70 Minimum Failing load kn Dimension, to AS : 2004 A B C Hole Approx. Weight kg ST ST ST STT

42 LINE HARDWARE TWISTED EYE TONGUE C PAGE 41 C A Material: Body - Galvanized forged steel D B E Minimum Failing load kn A B Dimension, C D E φ Approx. Weight kg TET TET TET

43 LINE HARDWARE BALL HOOK LONG SHANK C PAGE 42 A Material: Body - Galvanized forged steel C B The ball dimension is in accordance with AS : 2004 D F E Minimum Failing load kn A Dimension, to AS : 2004 B C D E (ball) F Approx. Weight kg BH-70-LS BH-120-LS BH-160-LS

44 LINE HARDWARE BALL HOOK SHORT SHANK C PAGE 43 A Material: Body - Galvanized forged steel B C The ball dimension is in accordance with AS : 2004 F D Minimum Failing load kn A Dimension, to AS : 2004 B C D E (ball) F Approx. Weight kg BH-70-SS BH-120-SS

45 LINE HARDWARE TONGUE HOOK C PAGE 44 Material: Body - Galvanized forged steel Minimum Failing load kn A Dimension, to AS : 2004 B C E φh K Approx. Weight kg TH

46 LINE HARDWARE SOCKET THIMBLE C PAGE 45 SOCTL-70 SOCT-70 Minimum Failing load kn Dimension, Socket Approx. Weight kg Material: Body - Galvanized ductile iron w clip Bronze. SOCT SOCTL

47 LINE HARDWARE CLEVIS THIMBLE C PAGE 46 D D A A Body style - CTHI-18 Aluminium alloy - CTHA-42 Body style - CTHAL-70 Minimum Failing load kn D Dimension, φ A Approx. Weight kg D CTHA CTHA CTHAL-70 CTHI Body style CTHA-2600 Material: Body Hardware Split pin - Galvanized ductile iron (CTHI-18) Aluminium alloy (CTHA-2600) Aluminium alloy (CTHA-42) Aluminium alloy (CTHAL-70) - Galvanized steel - Stainless steel

48 LINE HARDWARE ALUMINIUM PARALLEL GROOVE CLAMPS C PAGE 47 PGA PGA /3 Overall Diameter sq of bolts Length Approx. Weight kg Material: Body - Aluminium Bolts - Galvanized PGA- 1670/ PGA PGA / PGA / PGA / PGA /

49 LINE HARDWARE BIMETAL PARALLEL GROOVE CLAMPS C PAGE 48 Material: Body - Aluminium with a bimetallic sheet (hot forged) Bolts - Galvanized Overall Diameter Aluminium sq Aluminium Overall Diameter Copper sq Copper of bolts Length Approx. Weight kg PGB-1670/ PGB-35120/ PGB-251/ PGB-251/ PGB-16185/ PGB-35185/ PGB-35300/

50 LINE HARDWARE COPPER PARALLEL GROOVE CLAMPS C PAGE 49 Material: Body - Copper (Hot forged) Bolts - Copper alloy Overall Diameter sq of bolts Length Approx. Weight kg PGC-670/ PGC-1095/ PGC-161/

51 LINE HARDWARE BIMETAL SERVICE CLAMPS C PAGE Overall Diameter of bolts Approx. Weight kg ASC ASC Material: Body Split Bolt SuffixBolts - Aluminium - Tinned Brass -A-Aluminium S -Stainless steel G -Galvanized ASC1-S ASC2-S Conductor Overall Diameter Diameter of stirrup of bolts Approx. Weight kg ASC ASC Material: Body Stirrup Suffix Bolts - Aluminium - Tinned Copper - A - Aluminium S - Stainless steel G - Galvanized ASC5-A ASC4-A

52 LINE HARDWARE BIMETAL SERVICE TEES C PAGE 51 AST9-0-S Material: Body - Aluminium Stirrup - Tinned Copper Suffix Bolts - A- Aluminium S -Stainless steel G -Galvanized ASC5-8.25T DTA-1-S Conductor Overall Diameter Length 0 Approx. Weight kg 0.5 AST9-0- DTA-1- Conductor Overall Diameter Bail Solid Tinned Bronze Approx. Weight kg 0.6 ASC5-8.25T Solid Tinned Copper 0.3

53 LINE HARDWARE KU-LUGS C PAGE 52 D C B A Material: Body - High copper content alloy E Diameter Area sq A B C D E KU M8 6 KU M10 6 KU M12 7 KU M12 8 KU M16 10 KU M20 10 KU M20 13

54 LINE HARDWARE SPLIT BOLTS C PAGE 53 Material: Body - Tinned or Natural Brass Natural Brass Electro Tinned Slot Width () Max Conductor (sq) ESAA Cross Reference SB-22 SBT Type A SB-24 SBT Type B SB-25 SBT Type C SB-26 SBT Type D SB-28 SBT Type E

55 LINE HARDWARE SPLIT BOLTS C PAGE 54 Material: Hot dip galvanized A strong means of securing guy / stay wires A () B () C () D () E Nominal wire (dia.. ) F () G () WRG WRG WRG WRG

56 LINE HARDWARE GAIN BLOCK C PAGE 55 Material: Cast Aluminium Crossarm () GB-100 GB

57 LINE HARDWARE COMPRESSION DEAD END ACSR C PAGE 56 Eye tail Tongue tail ACSR Outside tube diameter Aluminium Inside tube diameter Aluminium A/F Aluminium Outside diameter Mm Steel Inside Diameter Steel A/F Steel CDE-ALMOND 6/1/ CDE-APPLE 6/1/ CDE-BANANA 6/1/ CDE-CHERRY 6/4.75+7/ CDE-GRAPE 30/7/ CDE-LEMON 30/7/ CDE-LIME 30/7/ CDE-MANGO 54/7/ CDE-ORANGE 54/7/ CDE-OLIVE 54/7/ CDE-PAWPAW 54/ / Please refer to our nearest sales office for further information

58 LINE HARDWARE COMPRESSION MIDSPAN ACSR C PAGE 57 ACSR Outside tube diameter Aluminium Inside tube diameter Aluminium A/F Aluminium Outside diameter Steel Inside diameter Steel A/F Steel CMJ-ALMOND 6/1/ CMJ-APPLE 6/1/ CMJ-BANANA 6/1/ CMJ-CHERRY 6/4.75+7/ CMJ-GRAPE 30/7/ CMJ-LEMON 30/7/ CMJ-LIME 30/7/ CMJ-MANGO 54/7/ CMJ-ORANGE 54/7/ CMJ-OLIVE 54/7/ CMJ-PAWPAW 54/ / Please refer to our nearest sales office for further information

59 LINE HARDWARE COMPRESSION DEAD END AAC & AAAC C PAGE 58 Eye tail Tongue tail AAC and AAAC Outside tube diameter Aluminium Inside tube diameter Aluminium A/F Aluminium AAC and AAAC Outside tube diameter Aluminium Inside tube diameter Aluminium A/F Aluminium CDE-LEO CDE-DIAMOND CDE-LIBRA CDE-EMERALD CDE-MARS CDE-GARNET 7/2. 7/3.00 7/ CDE-PLUTO CDE-PEARL CDE-SATURN CDE-RUBY CDE-TAURUS CDE-RUTILE 19/ / / CDE-MERCURY CDE-JADE 7/ CDE-TRITON CDE-SAPPHIRE 37/ CDE-MOON CDE-JASPER 7/ CDE-URANUS CDE-SPINEL 61/ CDE-NEPTUNE CDE-OPAL 19/ CDE-VENUS CDE-TOPAZ 61/ Please refer to our nearest sales office for further information

60 LINE HARDWARE COMPRESSION MIDSPAN AAC & AAAC C PAGE 59 AAC and AAAC Outside tube diameter Aluminium Inside tube diameter Aluminium A/F Aluminium AAC and AAAC Outside tube diameter Mm Aluminium Inside tube Diameter Mm Aluminium A/F Aluminium CMJ-LEO CMJ-DIAMOND 7/ CMJ-PLUTO CMJ-PEARL 19/ CMJ-LIBRA CMJ-EMERALD 7/ CMJ-SATURN CMJ-RUBY 37/ CMJ-MARS CMJ-GARNET 7/ CMJ-TAURUS CMJ-RUTILE 19/ CMJ-MERCURY CMJ-JADE 7/ CMJ-TRITON CMJ-SAPPHIRE 37/ CMJ-MOON CMJ-JASPER 7/ CMJ-URANUS CMJ-SPINEL 61/ CMJ-NEPTUNE CMJ-OPAL 19/ CMJ-VENUS CMJ-TOPAZ 61/ Please refer to our nearest sales office for further information

61 HELIXON FITTINGS INDEX D PAGE 60 Aluminium Deadend Type DE-A Page 61 Galvanized Steel Deadend Type DE-S. Page 62 Aluminium Armour Rods Type AR-A. Page 63 Galvanized Steel Armour Rods Type AR-S. Page 64 Aluminium Line Guards Type LG-A. Page 65 Aluminium Conductor Splices Type LS-A.. Page 66 Galvanized Steel Conductor Splices Type LS-S.. Page 67 Full Tension Conductor Splices Type LS-FT.. Page 68 Galvanized Steel Guy Lock Type GL-S. Page 69 Guy Guard Type GG-P Page 70 Spiral Vibration Damper Type HVD.. Page 71 Bird Diverters Type BFD. Page 72

62 HELIXON ALUMINIUM DEADENDS D PAGE 61 AAC AAAC Conductors ACSR Outside Diameter Pack Size AS1154 Colour Code DE-A /1.75 3/4/ Purple DE-A / Brown DE-A 07. 7/2. 6/1/2. 3/4/2. 7. Blue Type DE-A Aluminium Deadends Material Aluminium Deadends are manufactured using high strength, corrosion resistant aluminium alloy wire. Aluminium dead ends may be used in all environments. DE-A DE-A DE-A 13. 7/3.00 7/3.75 7/4. 6/1/3.00 4/3/3.00 6/1/3.75 4/3/ Red Black Green Rated Holding Strength Aluminium Deadends are designed to hold the full rated strength of Aluminium (AAC) or aluminium alloy (AAAC) conductors. Please consult Dulhunty for holding strength on ACSR conductors. DE-A DE-A DE-A 17. DE-A / / /3.75 6/1/ / /7/ Blue Orange Blue Black Tapping Current taps should not be attached over a deadend. Current taps should be made directly on the conductor on either side of the dead end. DE-A DE-A / / /7/ Red Blue

63 HELIXON GALVANIZED STEEL DEAD END D PAGE 62 Conductors SC/GZ Outside Diameter Pack Size AS1154 Colour Code DE-S / Yellow DE-S / Black Type DE-S Steel Deadends DE-S / White Material Steel Deadends are manufactured using high strength galvanized steel wire. Steel deadends may be used in all environments for which SC/GZ galvanized steel conductor or guy wire may be used. Rated Holding Strength Steel Deadends are designed to hold the rated strength of SC/GZ galvanized steel conductors and guy wires. DE-S DE-S DE-S 09.75D DE-S DE-S /2.00 7/2.75 7/ /2.00 7/3.75 7/ Yellow White Orange Yellow Black Black Tapping Current taps should not be attached over a deadend. Current taps should be made directly on the conductor on either side of the deadend. DE-S DE-S / / White Orange DE-S 0825, DE-S 0975 and DE-S 1375 are suitable for use with either a standard thimble, or with GY3 and GY4 insulators.

64 HELIXON ALUMINUM ARMOUR RODS D PAGE 63 AAC AAAC Conductors ACSR Outside Diameter Pack Size AS1154 Colour Code Type AR-A Aluminium Armour Rods AR-A /1.75 3/4/ Purple Material Aluminium Armour rods are manufactured using high strength corrosion resistant aluminium alloy wire. Aluminium armour rods may be used in all environments. AR-A AR-A 07. AR-A 07. AR-A /2.25 7/2. 7/3.00 6/1/2. 3/4/2. 6/1/ Brown Blue Blue Red Application Armour rods are designed to help prevent damage to conductors caused by bending, by high clamping stresses, by abrasion at support points and damage caused by arcing. Armour rods are not vibration dampers but help to prevent vibration damage to conductors by increasing the stiffness of the conductor at the support point and by preventing abrasion to the strands of the conductor. AR-A AR-A AR-A AR-A 13. AR-A AR-A /3.75 7/4. 7/ /3.25 4/3/3.00 6/1/3.75 4/3/3.75 6/4.75+7/ Red Black Black Green Blue Orange Armour rods can also be used to repair minor damage to the outer strands of the conductor. Please consult Dulhunty for specific information on damage repair. Tapping Taps may be applied over armour rods, but scratch brushing and greasing of the conductor is recoended if taps are to be applied. AR-A 17. AR-A AR-A AR-A 23.75D 19/ / / /7/2. 30/7/ Blue Red Red Blue

65 HELIXON GALVANISED ARMOUR RODS D PAGE 64 Type AR-S Steel Armour Rods Material Steel Armour rods are manufactured using high strength galvanized steel wire. Steel armour rods may be used in all environments for which galvanized steel conductors or guy wires are used. AR-S AR-S 04.80D Conductors SC/GZ 3/2.00 7/1.60 3/2.75 7/2.00 Outside Diameter Pack Size AS1154 Colour Code Yellow Black White Yellow Application Armour rods are designed to help prevent damage to conductors caused by bending, by high clamping stresses, by abrasion at support points and damage caused by arcing. Armour rods are not vibration dampers but help to prevent vibration damage to conductors by increasing the stiffness of the conductor at the support point and by preventing abrasion to the strands of the conductor. AR-S AR-S 09.75D AR-S AR-S /2.75 7/ /2.00 7/3.75 7/ White Orange Yellow Black Black Armour rods can also be used to repair minor damage to the outer strands of the conductor. Please consult Dulhunty for specific information on damage repair. AR-S AR-S / / White Orange Tapping Taps may be applied over armour rods, but scratch brushing and greasing of the conductor is recoended if taps are to be applied.. Note: Suffix D in Cat. No. denotes fitting suits more than one conductor.

66 HELIXON ALUMINIUM LINE GUARDS D PAGE 65 AAC AAAC Conductors ACSR Outside Diameter Pack Size AS1154 Colour Code Type LG-A Aluminium Line Guards LG-A /1.75 3/4/ Purple Material Aluminium Line Guards are manufactured using high strength corrosion resistant aluminium alloy wire. Aluminium Line Guards may be used in all environments. Application Line Guards are designed to help reduce damage to conductors caused, by abrasion at support points and damage caused by arcing. Armour rods should generally be used in areas where vibration is likely. Line Guards can also be used to repair minor damage to the outer strands of the conductor. Please consult Dulhunty for specific information on damage repair. Tapping Taps may be applied over Line Guards, but scratch brushing and greasing of the conductor is recoended if taps are to be applied. LG-A LG-A 07. LG-A LG-A LG-A 13. LG-A LG-A LG-A 17. LG-A LG-A LG-A /2.25 7/2. 7/3.00 7/3.75 7/4. 7/ / / / /4.75 6/1/2. 3/4/2. 6/1/3.00 4/3/3.00 6/1/3.75 4/3/3.75 6/4.75+7/ /7/2. 30/7/ Brown Blue Red Black Green Blue Orange Blue Black Red Blue

67 HELIXON ALUMINIUM CONDUCTOR SPLICES D PAGE 66 Conductors AAC AAAC Outside Diameter Pack Size AS1154 Colour Code LS-A / Purple Type LS-A Aluminium Splices Material Aluminium Splices are manufactured using high strength corrosion resistant aluminium alloy wire. Aluminium Splices may be used in all environments. Rated Holding Strength Aluminium Splices are designed to hold the full rated strength of Aluminium (AAC) or aluminium alloy (AAAC) conductors. Aluminium Splices are designed to carry the full oad current of AAC and AAAC conductors. Scratch brushing and greasing of the conductor is recoended prior to the installation of Aluminium Splices LS-A LS-A 07. LS-A LS-A LS-A 13. LS-A LS-A LS-A 17. LS-A 18. 7/2.25 7/2. 7/3.00 7/3.75 7/4. 7/ / / Brown Blue Red Black Green Blue Orange Blue Black Please consult Dulhunty for mechanical holding strength of Aluminium Splices on ACSR Conductors. LS-A LS-A / / Red Blue

68 HELIXON GALVANISED CONDUCTOR SPLICES D PAGE 67 Conductors SC/GZ Outside Diameter Pack Size AS1154 Colour Code LS-S / Yellow LS-S / Black LS-S / White Type LS-S Steel Splices LS-S / Yellow Material Steel Splices are manufactured using high strength galvanized steel wire. Steel Splices may be used in all environments for which galvanized steel conductor or guy wire may be used. LS-S LS-S 09.75D 7/2.75 7/ / White Orange Yellow Rated Holding Strength Steel Splices are designed to hold the full rated strength of galvanized steel conductors or guy wires. Steel Splices are designed to carry the full load current of galvanized steel conductors LS-S LS-S LS-S LS-S /3.75 7/ / / Black Black White Orange Note: Suffix D in Cat. No. denotes fitting suits more than one conductor.

69 HELIXON FULL TENSION CONDUCTOR SPLICES D PAGE 68 Conductors ACSR Outside Diameter Pack Size AS1154 Colour Code LS-FT 05.25M 3/4/ Purple LS-FT 07. 6/1/ Blue LS-FT 07.M 3/4/2. 7. Blue LS-FT /1/ Red Type LS-FT Full Tension Splices Material Full Tension Splices are two piece fittings with aluminium rods manufactured using high strength corrosion resistant aluminium alloy wire, and steel rods manufactured using high strength corrosion resistant aluminium alloy wire. Full Tension Splices may be used in all environments for which ACSR conductors are used. Rated Holding Strength Full Tension Splices are designed to hold the full rated strength of ACSR conductors. Aluminium Splices are designed to carry the full load current of ACSR conductors LS-FT 09.00M LS-FT LS-FT 11.25M LS-FT LS-FT 17. LS-FT /3/3.00 6/1/3.75 4/3/3.75 6/4.75+7/ /7/2. 30/7/ Red Black Black Blue Blue Red

70 HELIXON GALVANISED GUY LOCKS D PAGE 69 Conductors SC/GZ Outside Diameter Pack Size AS1154 Colour Code Type GL-S Steel Guy Locks GL-S / Yellow Material Steel guy locks are manufactured using high strength Galvanized steel wire. Steel guy locks may be used in all environments for which galvanized steel conductor or guy wire may be used. GL-S GL-S GL-S GL-S /1.60 3/2.75 7/2.00 7/ Black White Yellow White Rated Holding Strength Steel guy locks are designed to hold the full rated strength of galvanized steel guy wires. GL-S 09.75D 7/ / Orange Yellow GL-S / Black GL-S / Black GL-S / White GL-S / Orange Note: Suffix D in Cat. No. denotes fitting suits more than one conductor.

71 HELIXON GUY GUARDS D PAGE 70 Application: The Dulhunty Power Guy Guard improves visibility of pole stays to help avoid accidental contact with the guy wire. Internal Dia. Std Length Pack Size Material: White, UV resistant PVC. GG-P tube 2.0m GG-P 2520S 25 split tube 2.0m GG-P tube 2.0m GG-P 3020S 30 split tube 2.0m GG-P tube 2.5m GG-P tube 2.4m Notes: Suffix S in Cat. No. indicates fitting is split.

72 HELIXON HELIXON VIBRATION DAMPERS D PAGE 71 Type HVD Vibration Dampers Helixon Vibration dampers are designed to control vibration on small diameter conductors. Helixon Vibration dampers do not dissipate energy, but control vibration to disrupt vibration build up, by impacting on the conductor. HVD-044 HVD-063 Conductors Dia. Range Std Pack Colour Code Red Blue Material Helixon Vibration dampers are manufactured using a high impact strength, UV resistant plastic. They are suitable for use in all environments, and may be used for conductor temperatures up to 75C. HVD-083 HVD-117 HVD Black Yellow Green

73 HELIXON BIRD DIVERTERS D PAGE 72 5 metre 5 metre.2.5 metre stagger 5 metre 5 metre Typical spacing layout Application: The bird diverters manufactured by Dulhunty Power are designed to make power lines more visible for birds and to reduce the number of injuries to birds caused by striking power lines. BFD-044 Conductor Dia. Range Std Pack Colour Code Red Dulhunty Power bird diverters are orange, as this has been proven to be the most visible colour to the birds. Materials: High impact strength UV resistant PVC rod. BFD-063 BFD-083 BFD Blue Black Yellow Installation: Dulhunty Power recoends that the bird diverters should be installed on the outer conductors as shown in the diagram. BFD Green

74 STRAIN AND SUSPENSION CLAMPS INDEX E PAGE 73 Aluminium Suspension Clamp Type ASC. Page 74 Aluminium Pivot Suspension Clamp Type PSC. Page 75 Aluminium Trunnion Support Clamp Type TSC... Page 76 Helixon Suspension Clamp Type HSC.. Page 77 Cast Iron Suspension Clamp Type DSC. Page 78 Cast Iron Trunnion Support Clamp Type DTSC Page 79 Aluminium Strain Clamp Type ATC. Page 80 Cast Iron Strain Clamp Type DTC. Page 81

75 STRAIN AND SUSPENSION CLAMPS ALUMINIUM SUSPENSION CLAMP E PAGE 74 Clamp Range Rated Strength kn A Dimensions, B C D Approx. Weight kg ASC-85 5 ~ B ASC ~ ASC ~ ASC ~ C ASC ~ A ASC ~ A D ASC ~ ASC ~ Dulhunty Power Aluminium Suspension Clamps are designed for use with AAC, AAAC and ACSR in suspension applications for deviation angles of up to 20 deg. ASC ASC ~ ~ Material: Body and Keeper - Aluminium alloy Hardware -Galvanized steel Split Pin - Stainless steel

76 STRAIN AND SUSPENSION CLAMPS ALUMINIUM PIVOT SUSPENSION CLAMP E PAGE 75 Dulhunty Power Aluminium Pivot Suspension Clamps are designed for use with AAC,AAAC and ACSR in suspensionapplications for deviation angles of up to 20 deg. Material: Body and Keeper - Aluminium alloy Hardware -Galvanized steel Split Pin - Stainless steel Clamp Range Rated Strength kn A Dimensions, B C φ Approx. Weight kg PSC ~ PSC ~ PSC ~

77 STRAIN AND SUSPENSION CLAMPS ALUMINIUM TRUNNION SUPPORT CLAMP E PAGE 76 Dulhunty Power Trunnion Support Clamps are designed for use with AAC, AAAC and ACSR conductors and supported on horizontal or vertical line post insulators. Reversible keeper allows a large conductor range for each clamp size. Material: Body and Keeper - Aluminium alloy Clamp Range Rated Strength kn L Dimensions, W Bolt size Approx. Weight kg TSC ~ M TSC ~ M TSC ~ M TSC ~ M12 0.6

78 STRAIN AND SUSPENSION CLAMPS HELIXON SUSPENSION CLAMP E PAGE 77 Conductors O.D. Colour Code AAC/ AAAC ACSR Insert HSC HSC /3.00 7/3.75 6/1/3.00 4/3/3.00 6/1/3.75 4/3/ Red Black HSC housing HSC-13. 7/ Green HSC /4.75 6/1/ Blue HSC / Orange Helixon suspension clamp rods HSC-17. HSC / /7/ Blue Black HSC / /7/ Red HSC / Blue Dulhunty Power Helixon Suspension Clamps are designed for use with AAC, AAAC and ACSR conductors and offer superior vibration protection in severe vibration conditions. Please consult our sales office for DHSC

79 STRAIN AND SUSPENSION CLAMPS CAST IRON SUSPENSION CLAMP E PAGE 78 Dulhunty Power Suspension Clamps are designed for use with SC/GZ, SC/AC and other steel conductors in suspension applications. Material: Body and Keeper - galvanized cast iron Hardware - galvanized steel Split Pin - stainless steel DSCO-0615 Offset clamp Clamp Range Rated Strength kn Dimensions, L H Approx. Weight kg DSC-85 5 ~ DSC ~ DSC ~ DSC ~ DSC ~ DSCO ~

80 STRAIN AND SUSPENSION CLAMPS CAST IRON TRUNNION SUPPORT CLAMP E PAGE 79 Dulhunty Power Trunnion Support Clamps are designed for use with SC/GZ, SC/AC and other steel conductors in suspension Applications. Reversible keeper allows a large conductor range for each clamp size. Material: Body and Keeper - galvanized cast iron Clamp Range Rated Strength kn L Dimensions, W Bolt size Approx. Weight kg DTSC ~ DTSC ~ DTSC ~

81 STRAIN AND SUSPENSION CLAMPS ALUMINIUM STRAIN CLAMP E PAGE 80 A B Dulhunty Power Strain Clamps are designed for use with AAC, AAAC or ACSR conductor. D C E Material: Body and Keeper - Aluminium alloy Hardware - Galvanized steel Split pin - Stainless steel Clamp Range Rated Strength kn A B Dimensions, C D E NO. U-Bolts Size, Approx. Weight, kg ATC ~ ATC ~ ATC ~ ATC ~ ATC ~

82 STRAIN AND SUSPENSION CLAMPS CAST IRON STRAIN CLAMP E PAGE 81 A B D Dulhunty Power Strain Clamps are designed for use with SC/GZ, SC/AC and other steel conductors in suspension applications. C Material: Body and Keeper - Galvanized cast iron Hardware - Galvanized steel Split pin - Stainless steel Clamp Range Rated Strength kn A B Dimensions, C D NO. U-Bolts Size, Approx. Weight, kg DTC ~ DTC ~ DTC ~ DTC ~

83 FABRICATED FITTINGS INDEX F PAGE 82 Shackle Straps Type S-STRAP.. Page 83 "U" Shackle Straps Type S-STRAP.. Page 84 Cross Arm Brace Type X-BRACE.... Page 85 Stay Rods and Bows Type STAY Page 86 Saglinks Type SL. Page 87 Yoke Plates Type YPT... Page 88 Maintenance Tension Link Type MTL... Page 89 Link Plates Type LP & DLP. Page 90 Double Arming Bolts Type DAB. Page 91 Guy Thimble Closed Type GT.... Page 92 Guy Thimble Opened Type OGT.....Page 92 Eye Bolt Type EB.... Page 93 Pole Steps Type PS. Page 94 Line Pins and Hooks Type..... Page 95

84 Material: Galvanized Steel S-STRAP-5 Approx. Weight kg Dimension, L T W D B A S-STRAP S-STRAP S-STRAP S-STRAP-8 F SHACKLE STRAP FABRICATED FITTINGS PAGE 83

85 FABRICATED FITTINGS U SHACKLE STRAP F PAGE 84 Material: Galvanized Steel A B D1 Dimension, D2 W T L Approx. Weight kg S-STRAP S-STRAP

86 FABRICATED FITTINGS CROSS ARM BRACE F PAGE 85 Material: Galvanized Steel A B Dimension, D W T L Approx. Weight kg X-BRACE X-BRACE X-BRACE X-BRACE

87 FABRICATED FITTINGS STAY ROD AND BOW F PAGE 86 Material: Galvanized Steel A B Dimension, H L Approx. Weight kg STA-PNG STA-PNG STAY STAY STA-PNG-1 STA-PNG-2 STAY-2 STAY-4 STAY -3 STAY STAY-1 STAY-3

88 Material: Galvanized Steel ~ SL Minimum Failing Load kn ~ SL ~974 L 230~ SL SL T B A max Approx. Weight kg Dimension, F SAGLINK FABRICATED FITTINGS PAGE 87

89 FABRICATED FITTINGS YOKE PLATE F PAGE 88 Material: Galvanized Steel Consult Dulhunty Power for yoke plates to suit any string arrangement Minimum Failing Load kn A H Dimension, φ W R1 R2 Approx. Weight kg YPT YPT YPT YPT

90 FABRICATED FITTINGS MAINTENANCE TENSION LINK F PAGE 89 Material: Galvanized Steel Minimum Failing Load kn L1 L2 Dimension, L3 W R φ Approx. Weight kg MTL MTL

91 FABRICATED FITTINGS DOUBLE AND SINGLE LINK PLATES F PAGE 90 Single link plate Link Plate Assembly Link plates are available in 70/120/160 kn ratings and various lengths. Please refer to our nearest sales office for further information. Material: Body - Galvanized steel Hardware - Galvanized steel Split pin - Stainless steel Consult Dulhunty Power for link plates to suit any string arrangement Double Plate Links DLP DLP-70-1 DLP DLP-70-2 DLP DLP-70-3 Single Plate Links LP LP-70-1 LP LP-70-2 LP LP-70-3 Hole Center Distance

92 FABRICATED FITTINGS DOUBLE ARMING BOLTS F PAGE 91 Material: Galvanized Steel Overall Length Dimension, Thread length φ DAB DAB DAB DAB DAB DAB DAB

93 Material: Galvanized Steel OGT OGT OGT-25 3 T OGT OGT-12 B H D S Nom. Approx. Weight Per 100 kg Dimension, Approx. Weight Per 100 kg Dimension, T GT GT-22 A GT GT GT-12 G D C F GUY THIMBLE FABRICATED FITTINGS PAGE 92

94 Material: Galvanized Steel EB EB EB EB EB EB EB EB EB φ D M L Approx. Weight kg Dimension, EB EB EB EB EB EB EB EB EB φ D M L Approx. Weight kg Dimension, F EYE BOLT FABRICATED FITTINGS PAGE 93

95 FABRICATED FITTINGS POLE STEPS F PAGE 94 PS16-2 Knock in style PS16-2-S Screw in style Material: Galvanized Steel

96 FABRICATED FITTINGS LINE PINS AND HOOKS F PAGE 95 number FUSE-PIN M12 x 1 Pattern B head number COM-HOOK M12 x 1 Pattern B head number PIG-HOOK 16 Ball number PIG-TAIL M8 x 145 number J-HOOK M12 x 1 number L-HOOK M12 x 1

97 OTHER S INDEX G PAGE 96 Heat Shrink Products.Page Resin Filled Products Page Fibreglass Cabinets.. Page Residential Pillars and Bases. Page Transformer Shrouds. Page 110 Low Voltage Switches Page 111 Drop Out Fuses.. Page 112 Fuses.. Page 113 Linesman Equipment. Page Earthing Equipment Page Surge Arrestors... Page 125 Warning Markers. Page 126 Measuring Meters Page PLS-Cadd Software Page Corona Camera.... Page 134 Sagometer..... Page 135 Fault Indicators. Page Cat-1... Page 142 Polly-mar Shrouds.... Page 143 Emergency Towers..Page 144 Air break switches... Page 145 Automatic Deadends and Splices... Page

98 OTHER S CABLE JOINT S HEATSHRINK S G PAGE 97 Breakouts Insulating tape Right angle boots Sealing caps HV Inline joints LV Inline joint Termination kits Wrap around's

99 OTHER S CABLE JOINT S HEATSHRINK S G PAGE 98 High Voltage In-line Joint 22kV Single Core SPECIALISING IN HV TERMINATION KITS INDOOR AND OUTDOOR FROM - 3.3kV TO 36kV Please refer to our nearest sales office for further information

100 OTHER S CABLE JOINT S SELECTION CHARTS G PAGE 99 TERMINATIONS AND INLINE JOINTS HVT Termination for XLPE and Paper cables HVJ injoint for XLPE and Paper cables Please refer to our nearest sales office for further information

101 OTHER S CABLE JOINT S RESIN FILLED S G PAGE 100 Fully Tested Designed to meet requirements of BS6910 and CENELEC HD623 S1. Straight through and Branch Joints up to 300 sq All standard joints are supplied as a complete kit in a single carton. Each kit comprises a clear plastic shell, armour bond, a two-part polyurethane resin compound, gloves and jointing instructions. Connectors Joint kits can also be available with mechanical connectors or crimp sleeves. No special jointing skills Jointing is easy. Instructions are provided with each joint. Working space There is a choice of snap-lock shell or larger shell to provide even more working space. No heat Joints are filled with a two part high quality polyurethane resin compound which is supplied in a two-section self contained, non perishable bag enclosing both resin and hardener ensuring there is no contact with skin. No further protection The resin compound completely penetrates and sets solid within a plastic shell which effectively insulates, seals and protects the joint. It will not subsequently soften. Shelf life. Shelf life of the resin is 2 years when stored in well ventilated dry conditions between degrees. Range of joints V cables with stranded copper or solid aluminium conductors up to 300sq PVC, XLPE of EPR insulated, PILC,PVC sheathed single wire armoured, aluminium strip armour or unarmoured.

102 OTHER S CABLE JOINT S RESIN FILLED S G PAGE 101 E A B C D Straight through joint Tap off joint CJS-STRAIGHT 6 CJS-STRAIGHT 16 CJS-STRAIGHT 3570 CJS-STRAIGHT 120 CJS-STRAIGHT 185 Dimension, L D C Approx. resin content 200ml 4 ml 1.5 litre 4 litre 10 litre CJS-MB6 (OY) CJS-MB16 CJS-MB35 CJS-MB70 CJS-MB120 CJS-MB185 A Dimension, B C D E Approx. resin content 200ml 1 litre 2 litre 4 litre 10 litre 18 litre CJS-MB litre Recoendation We recoend that all resin kits are installed on de-energized cables. The resin kits detailed should only be installed by suitably qualified people.

103 OTHER S CABLE S LV AND HV FIBREGLASS CABINETS G PAGE 102 Description Size () Colour FPB10105V1D Fibreglass Cabinet Vented Single Door 1000Wx1000Hx0D Green/Beige FB-105 Fibreglass Base to match 1000Wx300Hx0D Green/Beige FPB10127V1D Fibreglass Cabinet Vented Single Door 1000Wx1200Hx700D Green/Beige FB-107 Fibreglass Base to match 1000Wx300Hx700D Green/Beige FPB13125V1D Fibreglass Cabinet Vented Single Door 1300Wx1200Hx0D Green/Beige FB-135 Fibreglass Base to match 1300Wx300Hx0D Green/Beige FPB13127V1D Fibreglass Cabinet Vented Single Door 1300Wx1200Hx700D Green/Beige FB-137 Fibreglass Glass Base to match 1300Wx300Hx700D Green/Beige FPB151275V1D Fibreglass Cabinet Vented Single Door 10Wx1200Hx7D Green/Beige FB-1575 Fibreglass Base to match 10Wx300Hx7D Green/Beige

104 OTHER S CABLE JOINT S COMMERCIAL FIBREGLASS CABINETS G PAGE 103 Description Size () Colour Kg FPBNF1V Fibreglass Pillar Vented 760Hx4Wx330D Beige/Green 7 FPBNF1V1D Fibreglass Pillar Vented Single Door 760Hx4Wx330D Beige/Green 8 FPBNF1V2D Fibreglass Pillar Vented Two Door 760Hx4Wx330D Beige/Green 9 FBNF1 Fibreglass Bass 310Hx565Wx335D Beige/Green 3.5 GSFPNF1 Type X S/Panel Blank/Frame Assy 700Hx420Wx10Thk Black 5 PSFB2 Security Bolts/Washers 4 Per Pillar G304 S/Stl SLP-1 Locking Plate suit Padlock 1 Per Pillar G304 S/Stl SLB-1 Locking Bolt suit SLP-1 1 Per Pillar G304 S/Stl

105 OTHER S CABLE JOINT S UNDERGROUND RESIDENTIAL PILLARS G PAGE 104 Wall Thickness 4 min Flame Retardancy 7 Degrees C Min (AS2420 AppB) Material: Polypropylene copolymer with additive rubberiser Cat No:URPL Dimensions Dimensions of the URPL and the URPLV are as shown. URPS Description Underground Residential Pillar Small Wall Thickness 4 Min URPSV Underground Residential Pillar Small Vented 4 Min URPL Underground Residential Pillar Large 4 Min URPLV Underground Residential Pillar Large Vented 4 Min

106 OTHER S CABLE JOINT S RESIDENTIAL PILLAR BASE G PAGE 105 Wall Thickness 4 min Flame Retardancy 7 Degrees C Min (AS2420 AppB) URPB Material: Polypropylene copolymer with additive rubberiser IP Rating: IP44 (Attached to Dulhunty Base) URPB URAB URDB URTS Description Underground Residential Pillar Base Underground Residential Allen Bolt Underground Residential D Head Bolt Underground Residential Tube Spanner Pack Size Each 4 4 Each URAB URTS Please contact our sales office for more details on our range of Fuse Panels

107 OTHER S G HEATSHRINK BOOTS 2 WAY LV CABLE BREAK OUT BOOT PAGE 106 E D d P F S E S E S E S TB S MAX TF S MAX LVCBR LVCBR LVCBR

108 OTHER S G HEATSHRINK BOOTS 3 WAY LV CABLE BREAK OUT BOOTS PAGE 107 E D d P F S E S E S E S TB S MAX TF S MAX LVCBR LVCBR LVCBR LVCBR LVCBR

109 OTHER S HEATSHRINK BOOTS 4 WAY LV CABLE BREAK OUT BOOTS G PAGE 108 E D d P F S E S E S E S TB S MAX TF S MAX LVCBR LVCBR LVCBR LVCBR

110 OTHER S HEATSHRINK END CAPS LOW VOLTAGE HEARTSHIRNK END CAPS G PAGE 109 H H L W EXP MIN REC MAX EXP MIN REC NOM EC EC EC EC EC EC EC EC EC-701U

111 OTHER S CABLE S TRANSFORMER SHROUDS G PAGE 110 Transformer Shroud 22kV Large P/N YAA833AA025 Transformer Shroud 11kV Small P/N YAA833AA004

112 LOW VOLTAGE SWITCHES LOW VOLTAGE SWITCHES G PAGE 111 LVI LVFI CATALOGUE No. TYPE RATED SHORT- TIME RATED VOLTAGE (U е )V RATED CURRENT (I e )AMP RATED MAKING CAPACITY RATED BREAKING CAPACITY CLEARANCE TO EARTH. CURRENT I/I e I c /I e NZ4284SECV LVI 20kA NZ4284SEQEB LVI 20kA NZ4298 LVI 36kA NZ4296SECV LVI 36kA NZ4239SECV LVFI 20kA NZ4239A LVFI 20kA NZ4286SECV LVFI 20kA

113 OTHER S DROPOUT FUSES G PAGE 112 STANDARD BASE UNITS Part no. Rated Voltage (U)kV Rate current (In) amp Rated Breaking Capacity Ka (sym) BIL kv Clearance to Earth Dry Arcing Distance 72298/15 12/ / /27 24/ /

114 OTHER S FUSES G PAGE 113 ZXC705-01BK37 Type K speed characteristics Amps D B Washer Yes SWE-ME-NB005 Amps 5 ZXC705-02BK Yes SWE-ME-NB ZXC705-03BK37 ZXC705-06BK37 ZXC705-08BK & Yes Yes Yes SWE-ME-NB015 SWE-ME-NB ZXC BK Yes SWE-ME-NB ZXC BK Yes SWE-ME-NB ZXC BK37 ZXC BK37 ZXC BK Yes Yes Yes SWE-ME-NB040 SWE-ME-NB ZXC BK Yes SWE-ME-NB0 ZXC BK37 ZXC705-0BK37 ZXC BK37 ZXC BK Yes Yes No No House service fuse Rated at 63 amp Single spring P/N SF100B Double spring P/N SF100A SWE-ME-NB060 SWE-ME-NB080 SWE-ME-NB ZXC BK No

115 OTHER S LINESMEN EQUIPMENT TOOLS G PAGE 114 Safety Belts P/N AB004 Full Harness P/N AB10A Pole Bucket Large Reinforced bottom heavy duty canvas 2 pockets 300x300 P/N PB-SIL-0021 Electrical Insulating Gloves Natural latex in 0V, 1000V, 70V 17000V and 260V Outer Protection Gloves Goat, Sheep and Kangaroo leather to be worn over Class 00 gloves Cowhide to be worn over Class 2,3,4 and 7 gloves Tool pouch P/N B-TPSFEA Belt and tools not included Canvas bag Zipper top 5x300x300 P/N CLCT24 Pole strap P/N AF725AU 2.5 meters AF735AU 3.5 meters

116 OTHER S LINESMEN EQUIPMENT TOOLS G PAGE 115 P/N ABC13-17 Ratchet Spanner P/N SB-3 Aluminium - White SB-4 Copper Black Scratch Brush P/N HES.240 Cable stripper 240sq P/N Modiewark P/N PP-1 Pole platform wooden pole P/N AC3920 Knife & scabbard P/N AV6410 IC semicon tool

117 OTHER S LINESMEN EQUIPMENT COMEALONG CLAMPS G PAGE 116 MGV4 MGV6 Max Safe Work Limit 20kN (2.0T) Max Safe Work Limit 20kN (2.0T) Cable Dia. Range 4 ~ 20 Cable Dia. Range 5 ~ 25 Jaw length 62 Jaw length 114 For use on Copper,Steel conductor, wire rope For use on Aluminium and Covered Conductor Weight 1.4kg Weight 2.2kg Safety latch and large eye lever Safety latch and large eye lever MGV5 Max Safe Work Limit 20kN (2.0T) ABC495 Cable Dia. Range 5 ~ 25 Max Safe Work Limit 20kN (2.0T) Jaw length 114 Cable Dia. Range 4 x 95sq For use on Weight Copper,Steel conductor, wire rope 2.2kg Safety latch and large eye lever Jaw length For use on Weight 190 LV ABC 5kg

118 OTHER S LINESMEN EQUIPMENT LUG ALL G PAGE 117 WIRE ROPE MODELS Load Capacity kgs Frame Size Approx. Weight kgs ANZ PS ANZ 7 small ANZ PS ANZ 680 small ANZ PSANZ 1020 small ANZ PS ANZ 1360 small ANZ PS ANZ 1020 medium ANZ PS ANZ 1360 medium ANZ medium 7.0 WEB STRAP MODELS 2-A A-1300 Load Capacity kgs Approx. Weight kgs Note: All web strapped models come complete with a carry bag 4-A

119 OTHER S LINESMEN EQUIPMENT LINDSAY UNIVERSAL STRINGING ROLLER Part number CSR5930 Roller Part number CSR 5900 adaptor 90 deg. Maximum diameter of conductor or splice Safe working load suspended or mounted Roller weight 5930 Combined Roller weight 5930 & kn 3.8 kg 5.2 kg 67.5 deg. 45 deg deg. G PAGE 118

120 OTHER S LINESMEN EQUIPMENT CABLE STRINGING ROLLER G PAGE 119 Suitable for Crossarm Rollers Approx. Weight kg CSR Nylon 2.3 CSR-5 1 Nylon 2.7

121 OTHER S LINESMEN EQUIPMENT HASTINGS G PAGE 120 Telescopic Hot Sticks TRIANGLE SHAPE Enables each section to Lock in automatically. No more twisting and turning to lock sections. HIGH VISIBILTY Fluorescent tips section is highly visible and has a foam core. All tips sections are 1.15 diameter. All sections are 100% tested per OSHA and ASTM F-711. EXTRA REACH- New 40 model now available. RE-DESIGNED LOCK BUTTONS- New shape and large size are easier to operate with and without gloves. MORE VERSATILE- Use only the number of required sections to perform each job, Example: A 40 FT. (12.2 Meters) tool can be reduced to a 20ft. (6.1 Meters) working height by depressing the lock button and sliding the bottom sections off. This allows for a lightweight tool to perform the work easier. P10060 EASY DISASSEMBLY- Simply depress the lock button and slide section, or sections, out. No tools are required for disassembly. ERGONOMIC DESIGN- Gives the operator a better gripping surface for better control. REDUCES INVENTORY- Only one size lock button and spring for replacement needs. EASY MAINTENANCE- All sections have a smooth glossy surface for routine cleaning and waxing. NEW BASE CAP- Cushions and protects base end. IMPROVED UNIVERSAL HEAD- Strong Aluminium alloy head incorporates corona discharge design and includes a captive Belleville washer to hold universal attachments securely. Locking button Side view LVP-1 P30142 End view showing triangular shape Extended Length Nominal Retracted Length Nominal Weight HV m 0.67 m 1.4 HV m 1.48 m, 1.6 HV m 1.53 m 2.2 HV m 1.58 m 2.9 P10044 Note. All telescopic hot sticks come complete with a carry bag HV-225 HV-230 HV-235 HV m 9.2 m 10.6 m 12.0 m 1.63 m 1.68 m 1.72 m 1.75 m

122 OTHER S LINESMEN EQUIPMENT CABLE CUTTERS G PAGE 121 P/N REL-9009 Ratchet Cutter Compact Up to 20 diameter ACSR P/N CC705 Cable cutter Copper up to 20 diameter. Aluminium up to 28 diameter. P/N 7116A Ratchet Cutter Compact Up to25 diameter ACSR Up to 32 diameter Alum P/N RC7118 Ratchet Cutter Compact Up to25 diameter ACSR Up to 28 diameter Alum P/N S200 Standard Guy Wire, Ground Rod, Rebar: 20 Capacity Aluminiumium and Copper Cable, ACSR: 20 Soft Steel Bolts: 20 Wire Rope: 20

123 OTHER S LINESMEN EQUIPMENT COMPRESSION TOOLS G PAGE 122 P/N REC-H130 Force at die face 120kN Battery operated P/N EP-510B Force at die face12 ton P/N EP-100W Force at die face 100kN P/N EP- Force at die face 5.2 ton P/N P-60 Cuts Aluminium or copper cable up to 60 diameter P/N EPH-130H Force at die face120kn

124 OTHER S LINESMEN EQUIPMENT EARTH SETS G PAGE 123 Part number PIMT-1 The PIMT style earth sets consist of a single extendable fiberglass earth stick, which can be removed. The PIMT earth sets can be supplied with earth rods. The PIMT earth sets are supplied in a canvas carry bag. PIMT-1 PIMT-2 PIMT-3 Please refer to our nearest sales office for further information

125 OTHER S LINESMEN EQUIPMENT EARTH RODS AND CLAMPS G PAGE 124 P/N CER x 1400 Pointed Copper bonded Ground Rods Complete with brass clip P/N ECP01 Suitable for 26 diameter pipe 16-35sq cable range Accepts 1 cable P/N EARTHCOMPOUND 11kg bags Earth enhancing compound P/N ECP1 P/N ECT10 Suitable for 43 diameter pipe - 120sq cable range Accepts 2 cable Suitable for 34 diameter pipe 16 35sq cable range Accepts 2 cable P/N ECB1 Suitable for diameter 16 35sq cable range Accepts 1 cable P/N CER diameter x 1800 Pointed Copper bonded Ground Rods P/N ECB2 Suitable for diameter 120sq cable range Accepts 2 cable P/N EC-210 Suitable for diameter sq cable range Accepts 1 cable

126 OTHER S SURGE ARRESTOR G PAGE 125 Rating Voltage Bracket 5kA 11kV SA11-05 No insulating brackets 5kA 11kV SA11-05-B Insulating bracket 5kA 22kV SA22-05 No insulating brackets 5kA 22kV SA22-05-B Insulating bracket 10kA 11kV SA11-10 No insulating brackets 10kA 11kV SA11-10-B Insulating bracket 10kA 22kV SA22-10 No insulating brackets 10kA 22kV SA22-10-B Insulating bracket 10kA 33kV SA33-10 No insulating brackets 10kA 33kV SA33-10-B Insulating bracket P/N SAMB Surge arrestor bracket

127 OTHER S WARNING MARKERS G PAGE 126 Marker ball Material : Fiberglass Live line marker ball 200 Material : High density polyethylene Diameter Orange Colour Red Yellow White AWM-600-O 600 O AWM-600-R 600 R AWM-600-Y 600 Y AWM-600-W 600 W AWM-300-O 300 O AWM-300-R 300 R AWM-300-Y 300 Y AWM-300-W 300 W

128 OTHER S MEASURING METERS /// G PAGE 127 IKE is a new category of Rapid Survey GIS data capture device Visual re-inspection from back in the office; Did that asset really need repair/replacement? No confusion of which asset needs maintenance. Ability to track how an asset s condition changes over time. Photo is tied to a spatial reference. IKE Sync desktop application comes with IKE Transfers data and image files from IKE, and performs DGPS post processing Please refer to our nearest sales office for further information

129 OTHER S SUPARULE G PAGE 128 SupaRule 600 SupaRule 600E Finest 707 Finest 8

130 OTHER S SUPARULE G PAGE 129 Model Users SupaRule One Cable Height Meter <15m 190 Mining SupaRule Cable Height Meter <15m SupaRule Cable Height Meter <23m SupaRule Railway Overhead Stagger meter 4<m< E ROM Distribution Transmission Railways Finest 707 Finest Analysing complex electrical and electronic circuits. General electrical maintenance e.g. portable appliance testing.

131 OTHER S MEASURING METERS G PAGE 130 Impulse XLR Trupulse 200 Yardage Pro 10 Yardage Pro 0 Tour XL

132 OTHER S MEASURING METERS G PAGE 131 LTI Impulse XLR Range, bearing, inclination Model 200XLR Users Transmission LTI Trupulse 200 range and inclination LTI Yardage Pro 0 Tour XL LTI Yardage Pro Elite 10 LT200 Y0 Y10 Distribution Distribution Transmission

133 OTHER S PLS-CADD SOFTWARE G PAGE 132

134 OTHER S PLS-CADD SOFTWARE G PAGE 133 PLS Lite /LOADS PLS -Survey Restricted version of PLS-CADD limited to the calculation of sags, tensions and structure loading trees. Restricted version of PLS-Cadd for surveyors and environmental display. PLS-CADD Basic PLS-CADD Optimum SAPS TOWER PLS-GMAST PLS-CPOLE PLS-WPOLE PLS-SPOLE CAISSON Complete line design prograe. (including SAGSEC, alignment, engineering and plotting modules but without automatic optimum spotting or optional structure prograes). PLS-CADD above two items plus Optimum spotting option (but without optional structure prograes). Non-linear analysis of Power & Counication Systems. Analysis and design of steel latticed tower. Analysis & design of transmission structure with modular guyed masts. Analysis & design of prestressed concrete poles and frames. Analysis & design of wood poles and frames. Analysis & design of steel poles and frames. Design of reinforced concrete pier foundation for pole.

135 OTHER S CORONA CAMERA G PAGE 134 DayCor Superb Superb is a professional portable daytime corona and arcing detection device specially designed to enhance and streamline maintenance tasks. Superb is a bi-spectral Solar Blind UV-Visible imager, designed to detect faint UV emissions in full daytlight with high signal to background ratio. Its ergonomic design and powerful optics enable convenient and efficient professional corona and arcing detection. Superb is reinforced with Ofil's reporting and analyzing software that offers flexible customized professional reports. DayCor Classic Classic is a professional daylight corona and arcing detection device ideal for high-voltage laboratories, research institutes, classrooms, workshops, etc. Classic is a bi-spectral Solar Blind UV-Visible imager, designed to detect very faint UV emissions in full daylight with high signal to background ratio. Its powerful optics and additional optional set of close-up lenses ensure detailed view of inspected objects and reveal reliably existing discharge of corona and arcing. Classic comes with a dedicated reporting and analyzing software with flexible customized professional reports. DayCor Rom Rom is the most sensitive airborne corona and arcing detection system in a gyro stabilized gimbaled payload. Rom is specially designed to provide high resolution video output of remotely inspected objects with high signal to background ratio. Rom enables safe and high speed flight inspection that streamlines maintenance tasks of long overhead lines. Rom s reporting software renders flexible customized professional reports DayCor Ranger Ranger is the corona and arcing detection solution for driven inspection. Ranger is an integration of the most sensitive UV emission detection system with a precise pan-and-tilt unit and a vehicle mount. Control over the inspection systems is from inside the vehicle. With Ranger inspections of long lines, comfortably, is facilitated. Ranger provides high resolution video output of remotely inspected objects with high signal to background ratio. Ranger streamlines maintenance tasks of long overhead lines. Ranger s reporting software renders flexible customized professional reports DayCor Rail Rail is the most reliable and sensitive corona and arcing detection system designed for railways special needs. Rail is a ruggedized system, equipped with shock observers, and capable of high speed automatic detection of corona and arcing. Rail provides high resolution video output of remotely inspected objects with high signal to background ratio. Rail s reporting software renders automatic straightforward reports.

136 OTHER S SAGO METER G PAGE 135 The Sagometer is a second-generation design of a new technology developed for the express purpose of accurately monitoring conductor ground clearance/sag on overhead transmission lines. The Sagometer provides the information needed to confidently: Study conductor behaviour for the purpose of validating and/or enhancing static rating Establish the dynamic rating for a monitored line Collect data on high-temperature conductor operation

137 OTHER S FAULT INDICATORS G PAGE 136 Merlin Gerin Fault Indicators. The Flite 11X range are single phase Fault Passage Indicators for Overhead Lines. They are used in a group of 3 units at each location in order to allow for the detection of all possible fault configurations. It must be installed at welldefined strategic locations along the overhead line such as the start of a spur, Load Break switch location or at the radial arms of a junction. They mount directly on the live HV conductor through a specially designed spring operated clamp. They can be fitted live line via a hot stick fitted with a special adapter. When a fault occurs all the Flite 11X located between the sub station and the faulted section will trip and start flashing whilst the Flite 11Xs located beyond the faulted section will stay idle. Flashers The red LED flash is very powerful and is seen on a solid angle of vision. The Flite 11X Range of Products: FLITE 110-SA can be adjusted on site with its embedded DIP switches. The light power of the Flite 110-SA is 40 lumen. Flite 116-SA has a similar design to the Flite 110-SA but incorporates a Short Range Radio to allow it to counicate with a G200 RTU and can be interfaced into SCADA applications via GSM and CDMA telephone networks using DNP3 protocol.

138 OTHER S FAULT INDICATORS G PAGE 137 Flite 110-SA Fault passage indicator for overhead networks Application A Fault Passage Indicator (FPI) is mandatory to locate faults on Distribution networks. It must match electrical network characteristics and be very visible in order to help maintenance crew to quickly locate network faults. A FPI must be coordinated with the upstream recloser or circuit breaker and therefore, depending on its location on the MV network, the trigger value may change. If need be, Flite 110-SA is adjustable on site thanks to its embedded dip-switches. One single product therefore covers all customer requirements. A FPI is always able to indicate permanent faults, but utilities are often interested to track transient faults as well (a fault is transient when the upstream protection device eliminates the fault and successfully recloses). Flite 110-SA offers both facilities with the same unit, flashing differently upon permanent faults and transient faults but with the same flash power. This feature is user adjustable: one single product therefore covers these two applications. Fault detection Flite 110-SA is fitted with two sensors, one measuring the magnetic field (image of the current) and one measuring the electric field (image of the voltage). A fault is either a passing over an absolute current threshold (Imax) or a current variation

139 OTHER S FAULT INDICATORS G PAGE 138 Flite 110-SA Detects both short-circuits and low current earth faults Self adaptation to network voltage and frequency Highly visible red flash light Indicates both permanent and transient faults User adjustable Very low power consumption Operation Upon installation on a live conductor, Flite 110-SA adjusts itself to power frequency and network voltage, then enables its fault detection function. Fault types: Flite 110-SA detects and indicates both earth faults and shortcircuits between phases. In addition Flite 110-SA indicates both permanent and transient faults. Fault confirmation: to avoid false indications, faults are confirmed with a voltage dip occurring within 70 s after the threshold has been reached, which indicates that the upstream protection system has opened the circuit or started a reclosing cycle. Inrush restraint: upon line energising, an inrush restraint filter avoids possible false fault indication due to transformer magnetising currents. Reset: once a permanent fault has been detected and flashing has started, upon power return, Flite 110-SA waits for the MV to stabilise before resetting its flash, thus avoiding to stop flashing if the fault has not been cleared. Transient fault evolution: once Flite 110-SA is busy flashing for a transient fault, if a permanent fault occurs, the flash fault indication automatically changes from transient to permanent, thus helping the maintenance crew to treat fault priorities (first permanent faults, then transient ones).

140 OTHER S FAULT INDICATORS G PAGE 139 Easergy Flite 116-SA and Easergy G200 Terminal Unit Remote Fault Indicators for overhead lines Application: fast location of faulted circuits Traditional Fault Passage Indicators (FPIs or FCIs) with visual indication are of limited use on distribution networks with long outgoing feeders. To know the status of FPIs, the utility has to perform a "line patrol" as soon as the feeder protection device (CB or recloser) trips. This patrol is time-consuming and some network sections may be hard to access: traffic jams in urban areas, difficult terrain in rural areas, long outgoing feeders. The solution is to use the remote indicating Flite116-SA. Payback is quick because the outage time decreases: gain in non distributed energy is substantial and quality of supply increases. Flite 116 counicates through a low power licence free radio with a G200 RTU able to collect and transmit the information to a feeder automation SCADA or utility SCADA using open protocols such as IEC or DNP3.

141 OTHER S G FAULT INDICATORS PAGE 140 Easergy Flite 116-SA and Easergy G200 Terminal Unit Application: fast location of faulted circuits The Flite 116-SA being a low power consumption unit, the G200 is used as a gateway to link the Flite 116-SA FPI's to any SCADA or W0 intranet maintenance software. The G200 unit is mounted on an overhead line pole close to the Flite 116 radio Fault Passage Indicator and counicates: On one side to the Flite 116 units, via a spread spectrum license free radio ( MHz) with low power consumption. On the other side to the distant acquisition system through a long range counication media: mobile telephone network (GSM/GPRS/CDMA) fixed telephone network (PSTN) radio (analog radio or radio modem) others through the local RS232 port. Basic functions The G200 basic functions are: Date and time stamp all events from Flite 116-SA DNP3 Protocol conversion for transmission to the SCADA system Send all the requested events to the W0 maintenance software and/or to the SCADA Allow remote parametering of Flite 116 units Allow local parametering of Flite 116 and G200 through the RS232 local port Storage capacity: 100 stamped events Monitoring in real time : MV presence/absance, load current

142 OTHER S FAULT INDICATORS G PAGE 141 Easergy Flite 116-SA and Easergy G200 Terminal Unit Fault detection Flite 116-SA is fitted with two sensors, one measuring the magnetic field (image of the current) and one measuring the electric field (image of the voltage). Upon installation on a live conductor, Flite 11X-SA adjusts itself to power frequency and network voltage, then enables its fault detection function. Fault types: Flite 116-SA detects and indicates earth faults (on di/dt scheme) and short-circuits with I MAX. Inrush restraint: upon line energizing, an inrush restraint filter avoids possible false fault indication due to transformer magnetising currents. Reset: by timer or by power return. Power Supply The G200 is powered by a 10W Solar Panel with a backup battery with a life up to 5 years. G200 unit with solar panel The Flite 116-SA is powered by a Lithium battery with a life of over 10 years and a total flash duration of >400Hours.

143 OTHER S CAT-1 G PAGE 142 CAT-1 TRANSMISSION LINE RATING SYSTEM* Increases transmission capability with maximum reliability No statistical risk-taking due to weather variability Eliminates clearance uncertainty caused by creep The CAT-1 system monitors the status of transmission lines by measuring the same parameters used to design the line. It measures the one parameter that is truly representative of the average condition of the conductor over an entire transmission line suspension section of several spans the tension. The Rating Principle Figure below represents a simplified example of a multispan transmission line suspension section. Because the suspension insulator strings at the suspension towers are free to swing longitudinally, the horizontal component H of the tension equalizes over the entire suspension section. Normally, the span shapes can be approximated as parabolas. Therefore, sags S1, S2 and S3 are all inversely proportional to the horizontal load H and directly proportional to the squares of the spans lengths L1, L2 and L3, regardless of conductor creep. By monitoring the conductor tension to verify that it remains above the minimum design limit, the design clearances at all points of the suspension section can be maintained. Transmission line suspension section. Horizontal tension remains constant over the entire suspension section (ruling span principle) CAT-1 OPERATING PHILOSOPHY The CAT-1 operating philosophy is based on recognising that weather variables are interrelated and probabilistic. The chances of both high temperature and low wind speed occurring along an entire suspension section are essentially zero. Thus, presently used ampacity limits can be increased by 15-25%. Although this causes a low finite risk, (typically less than 1%) of exceeding the limiting clearances, applying CAT-1 system will provide a reliable and accurate warning system for these potential clearance violations.

144 OTHER S POLLY-MAR SHROUD G PAGE 143 Damage caused by birds Removal by helicopter, of the shroud from composite insulators prior to energising Shed Diameter Length Colour Code POLLY-MAR7 Red POLLY-MAR9 Black POLLY-MAR3 Black POLLY-MAR12 Green POLLY-MAR8 Yellow POLLY-MAR2 Purple POLLY-MAR10 Blue

145 OTHER S EMERGENCY TOWER G PAGE 144 Emergency Tower Assembled 412 x 412 Tower Model With Accessories With the ground plate, the cone and a part section of the 412 x 412 (16 x16 ) 3m long module, an anchor plate bolted in and the gin pole, on ball bearings which makes it very easy to manoeuvre. The sliding gin pole allows you to install tower modules to any height without obstruction. Emergency Restoration Towers Transmission line maintenance. Bypass construction. Quick Power Restoration. From distribution to U.H.V. transmission line. I.S.O. certified.

146 OTHER S AIR BREAK SWITCH G PAGE 145 Standard Features Current carrying parts are manufactured from HD.HC. Copper. Silver plated contacts for high performance, low maintenance and long life. Terminal palms are bright tin plated for use with copper and aluminium connectors. Hinge end contact blade so that current path is not through pivot joint. Flicker arcing horns Adjustable phase centres Options Mounting : Pole top, mid pole and vertical Load break interrupters Insulators: Porcelain or Polymeric Poles Timber, metal or Concrete Crossarms: Aluminium, Steel or Insulated General purpose air break switch Rated Voltage 12/24kV to 36kV Rated Current 800A to 1000A BIL Rating 1kVp to 200kVp Consult Dulhunty Power for your requirements

147 OTHER S AUTOMATICS AUTOMATIC DEADENDS AND STRAND - VISE G PAGE 146 Steel deadend and stay wire deadend Universal Grade Strand-vise Dead Ends Diameter inch No. In Standard pack Type Range R5199 R A E 3.56 ~ 5.79 A D R5200 R A E 5.46 ~ 6.85 R A 6.85 ~ 8.00 R5202 R A E 8.26 ~ 9.96 E R616-SRI R5203 R A D 9.96 ~ R A ~ Consult Dulhunty Power for any fitting that may lie outside these ranges

148 OTHER S AUTOMATICS AUTOMATIC SPLICES G PAGE 147 Conductor Splice ACSR & AAAC Conduct-R-link Splice Conductor stranding ACSR Diameter inch No. In Standard pack Range R7652 6/1/ ~ 8.64 R7654 6/1/ ~ R7656AP 6/4.75+7/ ~ R7658AP 30/7/ ~ R7659AP 30/7/ ~ Consult Dulhunty Power for any fitting that may lie outside these ranges

149 OTHER S AUTOMATICS AUTOMATIC SPLICES G PAGE 148 Universal Grade Strand-link Splice Conductor stranding SC/GZ [Imp.] Diameter inch No. In Standard pack Range R39 3/2.00 7/1.60 [7/17] ~ 5.79 R40 3/2.75 [3/12] 7/ ~ 6.85 R42 7/2.75 [7/12] 7/3.25 [7/10] ~ 9.96 R43 19/2.00 [19/14] 7/ ~ R44 7/4.00 [7/8] ~ Consult Dulhunty Power for any fitting that may lie outside these ranges

150 OTHER S AUTOMATICS AUTOMATIC DEADENDS G PAGE 149 Copper conductor deadend Conduct-R-vise Dead Ends SDS Conductor stranding HDCC Diameter inch No. In Standard pack Range R41FDS R41SDS 7/1.75 7/ ~ 5.33 R47SDS 7/2.00 7/ ~ 6.73 R101SDS 7/2.75 7/ / / ~ 8.64 FDS R107SDS 7/3.00 7/ ~ 9.78 R207SDS 19/ / ~ Consult Dulhunty Power for any fitting that may lie outside these ranges

151 OTHER S AUTOMATICS AUTOMATIC SPLICES G PAGE 1 Copper conductor splice Conduct-R-link Splice Conductor stranding HDCC Diameter inch No. In Standard pack Range R61 7/ ~ 4.27 R41 7/1.75 7/ ~ 5.33 R47 7/2.00 7/ ~ 6.73 R27 7/ ~ 7.75 R101 7/2.75 7/ / / ~ 8.64 R107 7/3.00 7/ ~ 9.78 R207 19/ / ~ R407 19/ / ~ Consult Dulhunty Power for any fitting that may lie outside these ranges

152 OTHER S AUTOMATICS AUTOMATIC SPLICES AND STRAND - VISE G PAGE 151 Single wire fittings Wire-vise Dead Ends Wire-Link Splices WireVise Diameter Min MAX No. In Standard pack Style R57 R56V Link Vise R59 R58V Link Vise R63 R62V Link Vise Wire Link R65 R64V Link Vise RT-RBK 10 Ratchet tensioner Consult Dulhunty Power for any fitting that may lie outside these ranges RT-RBK

153 INSULATOR PINS INDEX H PAGE 152 INSULTOR PINS...

154 INSULATOR PINS INSULATOR PINS H PAGE 153 Design Reference: AS 1154 Material: Galvanized Steel Lead or Plastic heads available SWANECK Pin type AS1154 Cantilever Minimum failing load kn Diameter A Shank Length B Thread length Minimum C Minimum collar diameter D Stem length E Head pattern B/100/ B A/130/ A C/1/ C C/1/ C C/200/ C C/300/ C SWANECK B

155 INSULATORS INDEX I PAGE 154 AS INSULATOR.Page IEC INSULATOR Page ANSI INSULATOR.....Page 180 COMPSITE INSULATOR...Page

156 AUSTRALIAN STANDARD INSULATOR INDEX I PAGE 155 AS INSULATOR INDEX PORCELAIN INSULATOR: Ball & Socket Disc Insulator: Standard Profile.. Page 156 Tongue & Clevis Disc Insulator: Standard Profile Page 157 Ball & Socket Disc Insulator: Fog Profile... Page 158 Ball & Socket Disc Insulator: Desert Fog Profile.. Page 159 Tie Top Line Post Insulator. Page 160 Clamp Top Horizontal Line Post Insulator Page 161 Clamp Top Vertical Line Post Insulator. Page 162 Pin Type Standard Profile Insulator Page 163 Pin Type Aerodynamic Profile Insulator.. Page 164 Pin Type Fog Profile Insulator. Page 165 Spool and Shackle Type Insulator.. Page 166 Strain Type Insulator. Page 167 GLASS INSULATOR: Ball & Socket Disc Insulator: Standard profile. Page 168 Ball & Socket Disc Insulator: Fog profile... Page 169 Tongue & Clevis Insulator: Standard Profile Page 170 POST INSULATOR: QLD Station Post.Page 171

157 INSULATORS INSULATOR I PAGE 156 AS PORCELAIN INSULATOR Ball & Socket STANDARD PROFILE TYPE Diameter D Spacing H Creepage distance Coupling Size Min. Mechanical Failing Load kn Min. Routine Test Load kn Min. Lightning Impulse Withstand Volt. kv Power Frequency Withstand Volt. kv Min. Wet One Minute Min. Puncture Volt. Approx. Net Weight kg UP70BLZ UP80BL UP120BS UP160BL

158 INSULATORS INSULATOR I PAGE 157 AS PORCELAIN INSULATOR TONGUE & CLEVIS TYPE Diameter D Spacing H Creepage distance Coupling Size Min. Mechanical Failing Load kn Min. Routine Test Load N. cm Min. Lightning Impulse Withstand Volt. kv Power Frequency Withstand Volt. kv Min. Wet One Minute Min. Puncture Volt. Approx. Net Weight kg UP70C C UP70CP-HEX HEX

159 INSULATORS INSULATOR I PAGE 158 AS PORCELAIN INSULATOR Ball & Socket FOG PROFILE TYPE Diameter D Spacing H Creepage distance Coupling Size Min. Mechanical Failing Load kn Min. Routine Test Load kn Min. Lightning Impulse Withstand Volt. kv Power Frequency Withstand Volt. kv Min. Wet One Minute Min. Puncture Volt. Approx. Net Weight kg UP70BLP UP80BLP UP120BLP UP160BSP

160 AS PORCELAIN INSULATOR Ball & Socket DESERT FOG TYPE Type (IEC Class) XWP-70 XWP-100 XWP-160 Creepage distance, Disc diameter, D Unit spacing, H Power Frequency flashover voltage Power Frequency withstand voltage Wet, kv Dry., kv Wet., kv Dry, kv Standard coupling to IEC B 16B 20 M & E Combined stength, kn Net weight, kg Quantity per case 5 5 5

161 INSULATORS INSULATOR I PAGE 160 AS PORCELAIN INSULATOR TIE TOP LINE POST TYPE Type (AS Class) R11ET1N-310 R11ET145N R11ET325N R11ET325L R18ET1N Height & Diameter, stud, 310 x 165 x M x 146 x M x 200 x M x 184 x M x 166 x M20 Creepage distance, Protected Creepage distance, Power Frequency wet with, kv Impulse withstand, kv Cantilever strength, kn Net weight, kg

162 INSULATORS INSULATOR I PAGE 161 AS PORCELAIN INSULATOR CLAMP TOP HORIZONTAL LINE POST TYPE Type (AS Class) R11EH1N-1 R11EH1N R11EH325N R11EH3N Height & Diameter, stud, 540 x 146 x M x 170 x M x 184 x M24 Creepage distance, Protected Creepage distance, Power Frequency wet withstand, kv Impulse withstand, kv Cantilever strength, kn Net weight, kg

163 INSULATORS INSULATOR I PAGE 162 AS PORCELAIN INSULATOR CLAMP TOP VERTICAL LINE POST TYPE Type (AS Class) R11EC1N-1 R11EC1N R11EC325N R11EC3N Height & Diameter, stud, 775 x 170 x M24 Creepage distance, Protected Creepage distance, Power Frequency wet withstand, kv Impulse withstand, kv Cantilever strength, kn Net weight, kg

164 INSULATORS INSULATOR I PAGE 163 AS PORCELAIN INSULATOR STANDARD PROFILE PIN TYPE Type (AS Class) SLP/11/180 SLP/22/420 SLP/33/534 LP.LV Height & Diameter, Neck 110 X 1 X X 229 X X 257 X X 82 Creepage distance, Power Frequency wet withstand, kv Impulse withstand, kv Cantilever strength, kn Net weight, kg Insulator pin A/130/7 C/1/11 C/200/11 B/100/3.5 Quantity per case SLP Type LP.LV Type

165 INSULATORS INSULATOR I PAGE 164 AS PORCELAIN INSULATOR AERODYNAMIC PROFILE, C PIN TYPE Type (AS Class) ALP/11/275 ALP/22/4 ALP/22/490 ALP22/520 ALP33/710 ALP/33/920 Height and Diameter, Neck, (Radio Free) 160 X 1 X X 160 X 76RF 2 X 165 X X 200 X X 220 X X 240 X 76RF Creepage distance, P.F. wet withstand, kv Impulse withstand, kv Cantilever strength, kn Net weight, kg Insulator pin C/1/7 C/200/11 C/200/11 C/200/11 C/300/7 C/300/7 Quantity per case

166 INSULATORS INSULATOR I PAGE 165 AS PORCELAIN INSULATOR FOG PIN TYPE Type (AS Class) FLP/11/360 FLP/22/ Bridging Height & Diameter, Neck 160 X 152 X 76 A 200 X 2 X 76 C 210 X 140 X ø20 Creepage distance, Power Frequency wet withstand, kv 28 Impulse withstand, kv Cantilever strength, kn Net weight, kg Insulator pin A/130/7 C/1/11 C/200/11 Quantity per case radius chamfer Hole size Pattern C Zinc thread insert to AS

167 INSULATORS INSULATOR I PAGE 166 AS PORCELAIN INSULATOR SPOOL AND SHACKLE TYPE INSULATOR Type (AS Class) SH. LV. 1 SH.LV. 2 SH11 Height & Diameter, 54 x x 80 Creepage distance, 180 Power Frequency wet withstand, kv 30 Impulse withstand, kv 95 Transverse strength, kn Net weight, kg Quantity per case SH.LV Type SH 11

168 INSULATORS INSULATOR I PAGE 167 AS PORCELAIN INSULATOR STRAIN INSULATOR TYPE (AS Class) GY 2 GY 3 GY 4 V6/43 H Dimension, h h D d d Power Frequency wet withstand, kv Mechanical failing load, kn Net weight Quantity per case

169 INSULATORS INSULATOR I PAGE 168 AS GLASS INSULATOR Ball & Socket STANDARD TYPE Diameter D Spacing H Creepage distance Coupling Size Min. Mechanical Failing Load kn Min. Impact Failing Load N. cm Min. Lightning Impulse Withstand Volt. kv Power Frequency Withstand Volt. kv Min. Wet One Minute Min. Puncture Volt. Approx. Net Weight kg UG45BL UG70BLZ UG80BLZ UG125BLZ UG160BS

170 INSULATORS INSULATOR I PAGE 169 AS GLASS INSULATOR Ball & Socket FOG TYPE Diameter D Spacing H Creepage distance Coupling Size Min. Mechanical Failing Load kn Min. Impact Failing Load N. cm Min. Lightning Impulse Withstand Volt. kv Power Frequency Withstand Volt. kv Min. Wet One Minute Min. Puncture Volt. Approx. Net Weight kg UG70BP UG120BP UG160BP UG210BP

171 INSULATORS INSULATOR I PAGE 170 AS GLASS INSULATOR Tongue & Clevis TYPE Diameter D Spacing H Creepage distance Coupling Size Min. Mechanical Failing Load kn Min. Impact Failing Load N. cm Min. Lightning Impulse Withstand Volt. kv Power Frequency Withstand Volt. kv Min. Wet One Minute Min. Puncture Volt. Approx. Net Weight kg UG70C C

172 INSULATORS INSULATOR I PAGE 171 QLD STATION POST INSULATOR Type (IEC Class) Height & Diameter, PCD, Creepage distance, Withstand voltage Impulse, kv Cantilever strength, kn Torsion strength, N-m Net weight, kg C8-95-II x x P.F. wet, kv C6-200-II

173 INSULATORS INSULATOR I PAGE 172 IEC INSULATOR INDEX PORCELAIN INSULATOR: Solid-Core Station Post Insulator 6kN.. Page 173 Solid-Core Station Post Insulator 4kN.. Page 174 Solid-Core Station Post Insulator Multi Page 175 Ball & Socket Disc Insulator.. Page 176 Tongue & Clevis Disc Insulator.. Page 177 GLASS INSULATOR: Tongue & Clevis Disc Insulator...Page 178 Ball & Socket Disc Insulator Page 179

174 INSULATORS INSULATOR I PAGE 173 IEC 273 STATION POST INSULATOR Type (IEC Class) C6-95-II C6-125-II C6-1-II C6-170-II C6-200-II C6-2-II C6-325-II Height & Diameter, 255 x x x x x x x 190 PCD, Creepage distance, Withstand voltage P.F. wet, Kv Impulse, Kv Cantilever strength, kn Torsion strength, N-m Net weight, kg

175 INSULATORS INSULATOR I PAGE 174 IEC 273 STATION POST INSULATOR Type (IEC Class) C4-95-II C4-125-II C4-1-II C4-170-II C4-200-II C4-2-II C4-325-II Height & Diameter, 255 x x x x x x x 190 PCD, Creepage distance, Withstand voltage P.F. wet, Kv Impulse, kv Cantilever strength, kn Torsion strength, N-m Net weight, kg

176 INSULATORS INSULATOR I PAGE 175 IEC 273 STATION POST INSULATOR Type (IEC Class) C4-5-II C6-5-II C8-5-II C10-5-II C4-10-II C6-10-II C8-10-II Height & Diameter, 1200 x x x x x x x 2 PCD, Creepage distance, Withstand voltage P.F. wet, kv Impulse, kv Cantilever strength, kn Torsion strength, N-m Net weight, kg C-5-II Type C-10-II Type

177 U120BS U80BP U120BP U100BP U70BP U160BS U300B U210BS U100BL U80BL U70BL Min. Puncture Volt. Min. Wet One Minute Approx. Net Weight kg Power Frequency Withstand Volt. kv Min. Lightning Impulse Withstand Volt. kv Min. Routine Test Load kn Min. Mechanical Failing Load kn Coupling Size (IEC 120) Creepage distance Spacing H Diameter D (IEC type) IEC BALL AND SOCKET I INSULATOR PAGE 176 INSULATORS

178 C U80BP C U70BP C U80C C U70C Min. Puncture Volt. Min. Wet One Minute Approx. Net Weight kg Power Frequency Withstand Volt. kv Min. Lightning Impulse Withstand Volt. kv Min. Routine Test Load kn Min. Mechanical Failing Load kn Coupling Size (IEC 120) Creepage distance Spacing H Diameter D (IEC type) IEC TONGUE AND CLEVIS I INSULATOR PAGE 177 INSULATORS

179 INSULATORS INSULATOR I PAGE 178 IEC TOUGHENED GLASS INSULATOR Tongue & Clevis Diameter D Spacing H Creepage distance Coupling Size Min. Mechanical Failing Load kn Min. Impact Failing Load N. cm Min. Lightning Impulse Withstand Volt. kv Power Frequency Withstand Volt. kv Min. Wet One Minute Min. Puncture Volt. Approx. Net Weight kg DG-U70C C

180 DG-U210BP DG-U160BP DG-U120BP DG-U100BP DG-U70BP DG-U160BL DG-U160BS DG-U300B DG-U210BS DG-U120BL DG-U100BL DG-U80BL DG-U70BL DG-U70B DG-U70BS Min. Puncture Volt. Min. Wet One Minute Approx. Net Weight kg Power Frequency Withstand Volt. kv Min. Lightning Impulse Withstand Volt. kv Min. Impact Failing Load N. cm Min. Mechanical Failing Load kn Coupling Size Creepage distance Spacing H Diameter D IEC TOUGHENED GLASS INSULATOR Ball & Socket STANDARD PROFILE I INSULATOR PAGE 179 INSULATORS

181 INSULATORS INSULATOR I PAGE 180 ANSI INSULATOR Please refer to the ANSI Insulator For further information please call Dulhunty Power Ltd Tel:

182 COMPOSITZ INSULATOR INDEX I PAGE 181 Distribution DS M Series 15kV 28kV. Page 182 Long Rod Suspension / Tension: 1 Page 183 Long Rod Suspension / Tension: 2 Page 184 Line Post Insulator. Page 185 Line Post Base Insulators Page 186 Line Post End Fittings : 1 Page 187 Line Post End Fittings : 2 Page 188

183 COMPOSITZ INSULATOR DS-M SERIES I PAGE 182 DS-M Series 15kV 28kV RELIABLE COMPOSITZ INSULATORS DISTRIBUTION DS M Typical Line No. Section Length Dry Arc Leakage Electrical Flashover (kv) Weight Voltage 60 Hz CIFO kv Dry Wet Pos Neg Kg. 15 DS-15M DS-28M Available only in Australia, New Zealand and the South Pacific

184 COMPOSITZ INSULATOR COMPOSITZ INSULATOR I PAGE 183 RELIABLE COMPOSITZ INSULATORS LONG ROD SUSPENSION / TENSION S B X 0 TOWER LINE END FITTING LENGTH LEAKAGE CORONA TYPE (INCHES) LEVEL RINGS INSULATOR TYPE (SPECIFIED MECHANICAL LOAD) RPP INTERNAL USE ELECTRICAL AND DIMENSIONAL ORDERING EXAMPLE To order a 68 insulator with eye/ball end fittings, heavy contamination leakage,,000 SML rating the would be S298068BX00 Type Size SML kn RTL kn S S S S S S Y Clevis 5 -Tongue 6 -Clevis 7 -Socket 8 -Ball 9 -Eye Light Contamination A Heavy Contamination B Variable Leakage - V Tower Line A none 8 B- none 12 C- none 17 D -8 8 E F G 8 12 H V X - none none Available only in Australia, New Zealand and the South Pacific

185 RELIABLE COMPOSITZ INSULATORS LONG ROD SUSPENSION / TENSION SUSPENSION INSULATORS STRENGTH AND CLASSIFICATION OF AVAILABLE END FITTINGS BY ROD SIZE END FITTING TYPE INSULATOR ANSI IEC ANSI IEC ANSI IEC ANSI IEC ANSI IEC ANSI IEC S1 25klb *Yes *Yes 120kN *Yes 16-C S5 30klb *Yes *Yes S6+ 36 klb kN *Yes S2 lkb *Yes 52-10(1) *Yes 210 kn 19-C klb S4 80 klb *Yes (1) *Yes Available only in Australia, New Zealand and the South Pacific

186 COMPOSITZ INSULATOR COMPOSITZ INSULATOR I PAGE 185 RELIABLE COMPOSITZ INSULATORS LINE POST INSULATORS H B X 0 INSULATOR TYPE END FITTING TYPE NOMINAL LENGTH (INCHES) LEAKAGE LEVEL CORONA RINGS RPP INTERNAL USE Orientation H Horizontal Post V- Vertical Post Rod Diameter Base Type 1-2 Piece Flat SF-01 C-2 Piece Gain SG Bolt Circle 4-3 Stud Base 5-5 Bolt Circle 6-Swivel Base 8-No Base (anchor only) 9-2 Piece Gain X- none Line End Fitting 0-2 Hole Tongue 1-2 Hole Drop Tongue 2- Single Tunnion 3-3 Bolt Circle 4-3 Bolt Circle w/ Trunnion 5-5 Bolt Circle 6-5 Bolt Circle w/ Trunnion 7- F-Neck 9-3 Bolt Circle Short w/ Trunnion A-3 Bolt Circle (short) C- Extended Drop Tongue D- Double Trunnion X- None Tower Line A - none 6 B - no ne 11 X - none none Light Contamination A Heavy Contamination B Variable Leakage - V ELECTRICAL AND DIMENSIONAL ORDERING EXAMPLE To order a 40" insulator w ith a 2 Piece Gain steel base, 2 hole drop tongue, heavy contamination leakage, and 2.5" rod diameter, the w ould be H291040BX00 Available only in Australia, New Zealand and the South Pacific

187 COMPOSITZ INSULATOR COMPOSITZ INSULATOR I PAGE 186 Line Post Base Dimensions RELIABLE COMPOSITZ INSULATORS LINE POST BASES H2/H3 2 PIECE GAIN BASE H2FLAT BASE H2 ANCHOR H1 3 BOLT CIRCLE AND STUD BASE H2 SWIVEL BASE SG-01 GAIN BASE SF-01 FLAT BASE H2 5 BOLT CIRCLE Available only in Australia, New Zealand and the South Pacific

188 COMPOSITZ INSULATOR COMPOSITZ INSULATOR I PAGE 187 RELIABLE COMPOSITZ INSULATORS LINE POST END FITTINGS TRUNNION H2 2 HOLE TONGUE DROP TONGUE H2 & H3 DOUBLE TRUNNION H2 EXTENDED DROP EYE VERTICAL TRUNNION Available only in Australia, New Zealand and the South Pacific Dimensions next page

189 COMPOSITZ INSULATOR COMPOSITZ INSULATOR I PAGE 188 RELIABLE COMPOSITZ INSULATORS LINE POST END FITTINGS Line Fitting Ins A B C D E Mat. Trunnion H MCI Trunnion H MCI Trunnion H MCI Vertical Trunnion V MCI 66 kv Trident 2.5kN Vertical Trunnion V MCI Drop Eye H x 38 Al Drop Eye H x 38 MCI Drop Eye H x 38 MCI Refers to previous page (P186) 132kV Horizontal Vee 45kN Available only in Australia, New Zealand and the South Pacific

190 HIGH TEMPERATURE CONDUCTORS HIGH TEMPERATURE J PAGE 189

191 HIGH TEMPERATURE CONDUCTORS HIGH TEMPERATURE J PAGE 190

192 HIGH TEMPERATURE CONDUCTORS HIGH TEMPERATURE J PAGE 191 Page 191

193 CONDUCTORS INFORMATION INDEX K PAGE 192 AUSTRALIAN STANDARD CONDUCTORS Cross Sectional Comparison.... Page 193 Aluminium Conductor (Galvanised) Steel Reinforced... Page Aluminium Conductor (Galvanised) Steel Reinforced Extra High Strength. Page 197 Aluminium Conductor.. Page 198 All Aluminium Alloy Conductor Page 199 All Aluminium Alloy Conductor Page 200 Steel Conductor / Galvanised Page 201 Hard Drawn Copper Conductor Page 202

194 Conductor O.D. Inch Nominal. Cross Sectional Area ² Conductor O.D. Inch Nominal. Cross Sectional Area ² K CONDUCTORS INFORMATION PAGE 193 CONDUCTORS INFORMATION

195 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 194 Aluminium Conductor (Galvanised) Steel Reinforced ACSR/GZ / 13 Aust. Standard - AS 3607 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Almond 6/1/ Apple 6/1/ Banana 6/1/ Cherry 6/4.75+7/ Grape 30/7/ Lemon 30/7/ Lime 30/7/ Mango 54/7/ Orange 54/7/ Olive 54/7/ Pawpaw 54/ / Peach 54/ /

196 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 195 Aluminium Conductor (Aluminised) Steel Reinforced ACSR/AZ /13 Aust. Standard - AS 3607 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Barley 6/1/ Bean 6/1/ Cabbage 6/1/ Carrot 6/4.75+7/ Corn 30/7/ Garlic 30/7/ Millet 30/7/ Oats 54/7/ Onion 54/7/ Parsnip 54/7/ Potato 54/19/ Rice 54/ /

197 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 196 Aluminium Conductor (Aluminium Clad) Steel Reinforced ACSR/AC / 13 Aust. Standard - AS 3607 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Angling 6/1/ Archery 6/1/ Baseball 6/1/ Bowls 6/4.75+7/ Cricket 30/7/ Darts 30/7/ Diving 30/7/ Golf 54/7/ Gymnastics 54/7/ Hurdles 54/7/ Lacrosse 54/ / Rugby 54/ /

198 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 197 Aluminium Conductor (Galvanised) Steel Reinforced ACSR/GZ Aust. Standard - AS 3607 Extra High Strength Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Quince 3/4/ Raisin 3/4/ Sultana 4/3/ Walnut 4/3/

199 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 198 Aluminium Conductor AAC / 13 Aust. Standard - AS 1531 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Leo 7/ Libra 7/ Mars 7/ Mercury 7/ Moon 7/ Neptune 19/ Pluto 19/ Saturn 37/ Taurus 19/ Triton 37/ Uranus 61/ Venus 61/ Virgo 91/

200 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 199 All Aluminium Alloy Conductor AAAC 6201 Aust. Standard - AS 1531 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Diamond 7/ Dolomite 7/ Emerald 7/ Garnet 7/ Jade 7/ Jasper 7/ Opal 19/ Patronite 19/ Pearl 19/ Ruby 37/ Ruthenium 37/ Rutile 19/ Sapphire 37/ Spinel 61/ Tantalum 61/ Topaz 61/ Zircon 91/

201 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 200 All Aluminium Alloy Conductor AAAC 1120 Aust. Standard - AS 1531 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Chlorine 7/ Chromium 7/ Fluorine 7/ Helium 7/ Hydrogen 7/ Iodine 7/ Krypton 19/ Lutetium 19/ Neon 19/ Nitrogen 37/ Nobelium 37/ Oxygen 19/ Phosphorus 37/ Selenium 61/ Silicon 61/ Sulphur 61/

202 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 201 Steel Conductor / Galvanised SC/GZ Aust. Standard - AS 1222 Part 1 Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km 3/ / / / / / / / /

203 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 202 Hard Drawn Copper Conductor HDC Aust. Standard - AS 1746 Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km 7/ / / / / / / / / / / / / /

204 CONDUCTORS INFORMATION INDEX K PAGE 203 STANDARD CONDUCTORS All Aluminium Conductor to BS Page 204 Aluminium Conductor (Galvanised) Steel Reinforced to BS Page All Aluminium Conductor NZ... Page 207

205 All Aluminium Conductor ASC to BS 125 Nominated Mass kg per km Nominated Minimum Breaking Load kn Overall Diameter (approx) Strands/ Wire Diameter Code Name /5.23 Tarantula /4.65 Cicada /4.27 Scorpion /4.09 Maybug /5.36 Locust /3.78 Centipede /3.58 Drone /5.00 Moth /4.65 Butterfly /4.22 Cockroach /3.99 Spider /3.78 Chafer /3.53 Caterpillar /3.25 Hornet /5.36 Cricket /4.90 Bee /2.67 Beetle /4.39 Wasp /4.17 Clegg /3.91 Grasshopper /3.78 Earwig /3.66 Bluebottle /3.40 Fly /3.10 Ant /2.79 Ladybird /3.66 Weevil /2.59 Mosquito /3.35 Aphis /2.21 Gnat /2.06 Midge Nominated Mass kg per km Nominated Minimum Breaking Load kn Overall Diameter (approx) Strands/ Wire Diameter Code Name K CONDUCTORS INFORMATION PAGE 204 CONDUCTORS INFORMATION

206 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 205 Aluminium Conductor (Galvanized) Steel Reinforced ACSR to BS 215 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Mole 6/1/ Otter 6/1/ Squirrel 6/1/ Skunk 12/7/ Gopher 6/1/ Cat 6/1/ Weasel 6/1/ Horse 12/7/ Fox 6/1/ Hare 6/1/ Ferret 6/1/ Dog 6/4.72+7/ Rabbit 6/1/ Hyena 7/4.39+7/ Mink 6/1/ Cougar 18/1/ Beaver 6/1/ Leopard 6/5.28+7/ Racoon 6/1/ Coyote 26/2.54+7/

207 CONDUCTORS INFORMATION CONDUCTORS INFORMATION K PAGE 206 Aluminium Conductor (Galvanized) Steel Reinforced ACSR to BS 215 Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Code Name Strands/ Wire Diameter Overall Diameter (approx) Nominated Minimum Breaking Load kn Nominated Mass kg per km Tiger 30/7/ Goat 30/7/ Dingo 18/1/ Antelope 54/7/ Caracal 18/1/ Bison 54/7/ Wolf 30/7/ Sheep 30/7/ Jaguar 18/1/ Zebra 54/7/ Lynx 30/7/ Deer 30/7/ Panther 30/7/ Camel 54/7/ Lion 30/7/ Elk 30/7/ Bear 30/7/ Moose 54/7/ Batang 18/4.78+7/ Moa 76/3.72+7/

208 All Aluminium Conductor AAC NZ /4.72 Weke /4.40 Wasp /4.09 Moka /4.90 Bee /2.66 Beetle /3.91 Grasshopper /3.66 Rango /3.40 Fly /3.00 Kutu /2.80 Ladybird /2.36 Poko /2.05 Gnat /2.11 Namu Nominated Minimum Breaking Load kn Overall Diameter (approx) Strands/ Wire Diameter Mm Code Name /4.65 Cicada /4.64 Butterfly /4.21 Cockroach /3.78 Centipede /3.40 Spider /3.86 Mata /3.78 Chafer /3. Caterpillar /2.52 Huhu /3.35 Weta /3.25 Hornet /5.30 Cricket Nominated Minimum Breaking Load kn Overall Diameter (approx) Strands/ Wire Diameter Mm Code Name K CONDUCTORS INFORMATION PAGE 207 CONDUCTORS INFORMATION

209 DESCRIPTION INDEX DESCRIPTION INDEX * PAGE 208 A Air break switch Page 143 Aluminium deadends Page 59 Aluminium line guards Page 63 Aluminium line splices Page 64 Aluminium strain clamp Page 78 Aluminium suspension clamp Page 72 & 73 Aluminium trunnion support clamp Page 74 Anchor shackle Page 29 Armour rods aluminium Page 61 Armour rods steel Page 62 Automatic deadends Page 144 & 147 Automatic splices Page 145,146,148 B Bail clamps Page 48 Ball & socket disc insulator Page 154 Ball & socket disc insulator Glass Page 166 Ball & socket disc insulators: Fog profile Page 156 Ball & socket disc insulators: Standard profile Page 154 Ball & socket disc insulators: Desert Fog profile Page 157 Ball & socket disc insulators: Glass Fog profile Page 167 Ball clevis Page 31 Ball eye extension link Page 35 Ball eye link Page 30 Ball hook Page 40 & 41 Bird diverters Page 70 C Cable cutters Page 119 Cable rollers Page Cable stripper Page 113 Canvas tool bag Page 112 Cast bar spacer Page 28 Cast iron strain clamp Page 79 Cast iron support clamp Page 77 Cast iron suspension clamp Page 76 Cat-1 Page 140 CCT conductor fittings Page 19 Chain link Page 36 Clamp top horizontal line post insulator Page 159 Clamp top vertical line post insulator Page 160 Clevis thimble Page 44 Clevis tongue Page 32 Clevis tongue twisted Page 33 Closing tool Page 27 Combination hook Page 93 Comealong clamps Page 114 Compositz distribution DS M Series Page 180 Compression deadends Page 54 & 56 Compression midspan Page 55 & 57 Compression tools Page 120 Conductor high temperature Page Corona camera Page 132 Cross arm brace Page 83

210 DESCRIPTION INDEX DESCRIPTION INDEX * PAGE 209 D Deadend aluminium Page 59 Deadend steel Page 60 Double arming bolts Page 89 Dropout fuses Page 110 Dropout fuse links Page 111 E Earth set Page 121 Earth rod Page 122 Earth clamp Page 122 Emergency Tower Page 142 End caps Page 107 Eye bolt Page 91 Eye nut Page 8 F Fault indicators Page Fibreglass Cabinets Coercial Page 101 Fibreglass Cabinets LV & HV Page 100 Full tension line splice Page 66 Fuses Page 111 Fuse pin Page 93 G Gain blocks Page 53 G Galvanized steel deadend Page 60 Galvanized steel splice Page 65 Glass disc insulator Page Gloves Page 112 Guy guard Page 68 Guy lock Page 67 Guy thimble closed Page 90 Guy thimble opened Page 90 H Heat shrink products Page Helixon suspension clamp Page 75 High temperature conductor Page High voltage ABC products Page Hook bolt Page 7 Hook bracket Page 11 Hook nut & Eye nut Page 8 Horizontal mounting line post insulator Page 159 HVABC stringing equipment Page 18 I Insulator Pins Page 151 Insulation piercing connector Page 9 J J Hook Page 93

211 DESCRIPTION INDEX DESCRIPTION INDEX * PAGE 210 K KU-Lugs Page L L hook Page 93 LV ABC suspension clamp Page 4 LV ABC tension clamp Page 6 LV ABC weak link Page 7 LV boots Page Line pin & hooks Page 93 Line post bases Page 185 Line post end fittings 1 Page 186 Line post end fittings 2 Page 187 Line post insulator Page 184 Linesmen equipment Page Line stringing rollers Page Line tap Page 51 Link plates Page 88 Long rod suspension Page 182 & 183 Low voltage resin kits Page 98 & 99 Low voltage switch Page 109 Lugall Page 115 M Maintenance tension link Page 87 Measuring meters Page Modiewark Page 113 N O P Parallel groove clamps- Aluminium Page 45 Parallel groove clamps- Bi-metal Page 46 Parallel groove clamps- Copper Page 47 Pig hook Page 93 Pig tail Page 93 Pillar Base Residential Page 103 Pillars Underground Residential Page 102 Pin type aerodynamic profile insulator AS Page 162 Pin type fog profile insulator AS Page 163 Pin type standard profile insulator AS Page 161 PLS CADD Page 130 & 131 Pole bucket Page 112 Pole platform Page 113 Pole step Page 92 Pole strap Page 112 Polly-mar shroud Page 141 Porcelain disc insulator ANSI Page 178 Porcelain disc insulator AS Page Porcelain disc insulator Desert AS Page 157 Porcelain disc insulator Fog AS Page 156 Q Quad spacer damper Page 25

212 DESCRIPTION INDEX DESCRIPTION INDEX * PAGE 211 R Ratchet spanner Page 113 Resin kits Page 98 & 99 S Safety belts Page 112 Sagometer Page 133 Sag links Page 85 Scratch brush Page 113 Service fuse holder Page 111 Service puller Page 118 Service clamps Page 48 & 49 Shackle straps Page 81 & 82 Shrouds Page 108 & 141 Six bundle spacer damper Page 26 Socket clevis Page 37 Socket clevis extension link Page 34 Socket thimble Page 43 Socket tongue Page 38 Solid-Core station post insulator 4kN Page 172 Solid-Core station post insulator 6kN Page 171 Solid-Core station post insulator Multi Page 173 Spanner LV ABC Page 113 Spiral vibration damper Page 69 Split bolts Page 51 Spool & shackle type insulator AS Page 164 Spool type insulator ANSI Page 178 S Stay rod & bow Page 84 Steel guy lock Page 67 Steel line splices Page 65 Strain insulator AS Page 165 Stringing rollers Page 116 & 117 Stripping tool Page 113 Suspension Clamp & Extension Rollers Page 5 Suspension clamp LVABC Page 4 Suspension clamp HVABC Page 17 Suspension clamp Helixon Page 75 SupaRule Page 126 & 127 Surge arrestors Page 123

213 DESCRIPTION INDEX DESCRIPTION INDEX * PAGE 212 T Telescopic hot sticks Page 118 Tension clamp LVABC Page 6 Tongue & clevis disc insulator ANSI Page 178 Tongue & clevis disc insulator Glass Page 168 Tongue & clevis disc insulator Porcelain Page 155 Tongue & clevis insulator IEC Page 175 & 176 Tongue hook Page 42 Tool Bag Page 112 Transformer shrouds Page 108 Triple spacer Page 24 Twin spacer Page 22 & 28 Twin spacer damper Page 23 Twisted eye tongue Page 39 Twisted clevis tongue Page 33 U "U" shackle straps Page 82 Underground pillars and bases Page V Vertical mounting line post insulator Page 160 Vibration damper type 4D Page 21 Vibration damper type Spiral Page 69 W Warning markers Page 124 Weak link Page 7 Wedges Page 12 Winch Lugall Page 115 Wire rope grips Page 52 X Cross arm braces Page 83 Y Yardage pro Page 128 & 129 Yoke - LVABC Page 10 Yoke plate Page 86 Z

214 DULHUNTY POWER DISPLAY DULHUNTY POWER DISPLAY * PAGE 213

215

216 CONTACTS CONTACTS * Dulhunty Power (Aust) Pty Ltd Unit 2/35 Waterloo Road, North Ryde Sydney NSW 2113, Australia Telephone: Facsimile: sales@dulhunty.com Web: Dulhunty Power (N.Z.) Ltd PO Box 281 Whangaparaoa Auckland New Zealand Telephone Facsimile: brian@dulhunty.co.nz Web: Dulhunty Power (H.K.) Ltd 2403 World Trade Centre 280 Gloucester Road Causeway Bay, Hong Kong Telephone: Facsimile: sales@dulhuntychina.com Web: Dulhunty Power (Malaysia) Sdn. Bhd. Lot 8040, Jalan 2/D Kg. Baru Subang 401 Shah Alam Selangor Darul Ehsan, Malaysia Telephone Facsimile: enquiry@dulhunty.com.my Web: Dulhunty Power (Thailand) Ltd 3/2 Moo 7, Suwintawong Road Klongluangpang, AmphurMuang Chachoengsao 24000, Thailand Telephone Facsimile: pana@dulhunty.co.th Web: Dulhunty Power (China) Ltd 3303#, Zhuan Qiao, Jiangdu Jiangsu, P.R.C. Telephone: Facsimile: sales@dulhuntychina.com Web:

LINE FITTINGS I N D E X

LINE FITTINGS I N D E X LINE FITTINGS I N D E X LINE FITTINGS Anchor Shackles Type AS. Page C-2 Ball Eye Links Type BEL...Page C-3 Ball Clevis Type BC. Page C-4 Clevis Tongues Type CT.Page C-5 Twisted Clevis Tongues Type TCT.

More information

STRAIN AND SUSPENSION CLAMPS

STRAIN AND SUSPENSION CLAMPS STRAIN AND SUSPENSION CLAMPS I N D E X STRAIN AND SUSPENSION CLAMPS Aluminium Suspension s Type ASC. Page D-2 Aluminium Pivot Suspension s Type PSC. Page D-3 Aluminium Pivot Support s Type TSC... Page

More information

FABRICATED FITTINGS I N D E X

FABRICATED FITTINGS I N D E X I N D E X FABRICATED FITTINGS Shackle Straps Type S-STRAP.. Page E-2 "U" Shackle Straps Type S-STRAP.. Page E-3 Cross Arm Braces Type X-BRACE.... Page E-4 Stay Rods and Bows Type STAY...... Page E-5 Saglinks

More information

Section 4 - Protection

Section 4 - Protection Transmission Catalogue : Section 4 Protection Section 4 - Protection Table of Contents Section/Page PREFORMED Armor Rods For AAC, AAAC and ACSR s... 4-3 For AAC, AAAC and ACSR s (Subset)... 4-3 For SC/GZ

More information

PROTECTIVE FITTINGS I N D E X

PROTECTIVE FITTINGS I N D E X I N D E X PROTECTIVE FITTINGS Vibration Dampers Type 4D. Page B-2 & B-3 Twin Spacer-dampers Type SD2.. Page B-5 Triple Spacer-dampers Type SD3.. Page B-6 Quad Spacer-dampers Type SD4.. Page B-7 Six bundle

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

EARTH WIRE FITTINGS 08

EARTH WIRE FITTINGS 08 EARTH WIRE FITTINGS 08 8 EARTH WIRE FITTINGS 119 Contents General... 120 C-bracket... 123 Suspension clamp with bolt, with straps, for steel and copper conductors... 123 Suspension clamp with bolt, with

More information

DISTRIBUTION catalogue

DISTRIBUTION catalogue hardware & accessories jointing DISTRIBUTION catalogue Australian Manufactured Overhead Fittings for Power Distribution termination DISTRIBUTION catalogue protection Also available: Transmission Catalogue

More information

Section 7 - Hardware & Fittings

Section 7 - Hardware & Fittings Transmission Transmission: Catalogue : Section 7 Section 7 - Table of Contents Sec/Page Table of Contents Sec/Page Aluminium Sheave... 7-6 Arcing Horn... 7-5 Ball 'Y' Clevis... 7-4 Ball Clevis... 7-8 Ball

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS Sl. 1 260200003A STEEL TUBULAR POLE SWAGED 11 MTR. LONG WITH BASE 7651.62 8034.20 8435.91 PLATE & CAP (IS2713/1980) BTM: 165.1X4.5MM-5.6MTR,

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

Company Profile. ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees.

Company Profile. ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees. Company Profile ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees. We provide products such as electrical fittings, optical

More information

S. K. Industrial Corporation

S. K. Industrial Corporation +91-8048763042 S. K. Industrial Corporation https://www.indiamart.com/skindlcorpn/ We are an ISO 9001 : 2008 certified company. We are manufacturing, exporting and supplying HT and LT transmission line,

More information

+91-8048571184 UB Exim Private Limited http://www.ubexim.in/ We are amongst the leading exporters, manufacturers, suppliers and traders, of this highly commendable and diverse range of Electrical Spares

More information

STRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS

STRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS 172 Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com STRAIN LINK STICK Used as insulation between rope blocks and a hot line wire grip For deadend structures and running corners Attached to conductor

More information

PART NUMBER POLE DIAMETER RANGE CARTON QTY " to 5" " to 6 3 4" " to 7 3 4" " to 8 3 4" 10

PART NUMBER POLE DIAMETER RANGE CARTON QTY  to 5  to 6 3 4  to 7 3 4  to 8 3 4 10 PH1 Offset Pole Band Bands Single Double Offset Pole Bands are used for dead-ending, guying, and mounting secondary racks on metal poles, pipe masts, or conduit. Each Pole Band Assembly contains two 1

More information

Transmission Tools. Catalog 2250 May Transmission Tools Phone: Web: hubbellpowersystems.

Transmission Tools. Catalog 2250 May Transmission Tools Phone: Web: hubbellpowersystems. Transmission Tools Catalog 2250 May 2016 Transmission Tools 2250 May 2016 Page 2251 STRAIN LINK STICK Tested per OSHA & ASTM F711 Used as insulation between rope blocks and a hot line wire grip For deadend

More information

OPTOFIT CATALOGUE. FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES.

OPTOFIT CATALOGUE. FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES. OPTOFIT CATALOGUE FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES. EXCLUSIVE AUSTRALIAN DISTRIBUTORS B8/8 Introduction Metalfree (ADSS

More information

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E 17 DISTRIBUTION OHL FITTINGS 01 Contents General... 3 Insulator pin straight with round thread, according to ÖNORM E4175... 5 Oscillating top clamp for aluminium based conductors... 5 Side tie for aluminium

More information

THERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR)

THERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR) Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR) July 2015 History of Hardware at PLP Preformed Line Products has been involved with the design, testing and production of hardware and

More information

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS Made from high impact, UV resistant, polyvinyl chloride (PVC), they are non-corrosive and do not abrade the conductor or require

More information

Line Hardware. Ball Hooks & Tongue Hook. Line Hardware. Minimum Failing Load. Dimensions A B E F (Ball) S Material Fig. No.

Line Hardware. Ball Hooks & Tongue Hook. Line Hardware. Minimum Failing Load. Dimensions A B E F (Ball) S Material Fig. No. all ooks & Tongue ook Optional hole for safety latch S ig. all ook Short Shank ig. 2 all ook Long Shank Optional hole for safety latch o5.5 S o hole 22 Cat SS SS LS T ailing Load kn (all) S Material 25

More information

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings Insulation Piercing Connectors Dulmison, through its partnership with Michaud in France, provide a comprehensive range of Insulation Piercing Connectors - IPC's. Michaud's dedication to product quality

More information

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS Transmission: Section 1 NOMENCLATURE Single Support and Double Support : Identified by S and D appearing in the length column on the catalog page. Should the maximum distance between tied supports exceed

More information

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01 SECTION H EARTHING ABC Earthing Kits H01 ABC Earthing Kit 4 legged ABC earth kit. Each leg of the earth truss terminates with a female bayonet type pipe connector with a protective rubber hand guard. These

More information

EXCLUSIVE AUSTRALIAN DISTRIBUTORS

EXCLUSIVE AUSTRALIAN DISTRIBUTORS Helical Fittings EXCLUSIVE AUSTRALIAN DISTRIBUTORS B4/1 Introduction in helical fittings Helical fittings are composed of single helical rods which -according to the respective application - are separate

More information

Power Transmission Equipment. Allbest Creative Development Ltd. (ALLBEST)

Power Transmission Equipment. Allbest Creative Development Ltd. (ALLBEST) Power Transmission Equipment Allbest Creative Development Ltd. (ALLBEST) Technology Portfolio Integrated Technology and Equipment for Power Substation & Transmission Line Substation Steel Tube Tower for

More information

PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY

PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 Catalog IX.1 American Design American Made Our success

More information

Section 6 FIBERLIGN Hardware for ADSS

Section 6 FIBERLIGN Hardware for ADSS FIBERLIGN Hardware for ADSS: Section 6 Section 6 FIBERLIGN Hardware for ADSS Table of Contents Page Fiber Optic Product Layout for ADSS...6-2 FIBERLIGN Lite Tension Dead-end for ADSS...6-3 FIBERLIGN Dielectric

More information

Distribution Design Catalogue

Distribution Design Catalogue Distribution Design Catalogue Running Earth and Street Light Feed Section 03 (RE) Copyright of Western Power ABN 18540492861 RE Drawings Revision List CU DATE REVISION OF REVISION Sept 2002 Original Issue

More information

AERIAL. a Nexans company. Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone Cable Sales Phone 1300 CABLES

AERIAL. a Nexans company. Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone Cable Sales Phone 1300 CABLES Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone 613 9281 4444 Cable Sales Phone 1300 CABLES New Zealand Paraite Road Bell Block New Plymouth New Zealand Phone 646 755 9800

More information

Contents Stay Rod Assembly Base Plates Cross Arms A Frames Platforms Threaded Rods Threaded Rod Assembly Overhead Line Hardware Stringing Hardware

Contents Stay Rod Assembly Base Plates Cross Arms A Frames Platforms Threaded Rods Threaded Rod Assembly Overhead Line Hardware Stringing Hardware Contents Stay Rod Assembly 1 Base Plates 1 Cross Arms 2 A Frames 2 Platforms 2 Threaded Rods 3 Threaded Rod Assembly 3 Overhead Line Hardware 4 Stringing Hardware 4 Dead Ends 5 Wrap-Lock Ties 5 Side Ties

More information

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016 No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979

More information

The reinforcing rods are incorporated in this assembly to ensure the optical fibres within the OPGW Range

The reinforcing rods are incorporated in this assembly to ensure the optical fibres within the OPGW Range OPGW Suspension Assemblies Optical Fibre Cable Same lay as OPGW outer stranding H Reinforcing rods opposite lay to OPGW outer stranding S L Application Heliformed suspension assemblies designed for use

More information

SPACERS AND SPACER DAMPERS

SPACERS AND SPACER DAMPERS SPACERS AND SPACER DAMPERS 0 131 Contents General... 132 Spacer damper aluminium, for horizontal twin bundles... 138 Spacer damper aluminium, for vertical twin bundles... 138 Spacer damper aluminium, for

More information

Conductor Protection. results

Conductor Protection. results Conductor Protection results Conductor Protection Index Dampers 607... Vibration Damper 4R Stockbridge...1 Armor Rods AP8... Aluminum Armor Rods...6 APS... alvanized Steel Armor Rods...8 APAS... AluminumClad

More information

Conductor. Isolators. Technical Specification:- Sr.N Description of Item Offered value. DC Resistance at 20 C (Ohms/Km) Weig ht (Kg.

Conductor. Isolators. Technical Specification:- Sr.N Description of Item Offered value. DC Resistance at 20 C (Ohms/Km) Weig ht (Kg. PRODUCTS Conductors SPECIFICATION We deal in all varieties of HT & LT distribution and transmission line aluminum conductors. ACSR,AAC & AAAC type Copper Conductors of various sizes are also available.

More information

Distribution Design Catalogue

Distribution Design Catalogue Distribution Design Catalogue Running Earth and Street Light Feed Section 03 (RE) Copyright of Western Power ABN 18540492861 RE Drawings Revision List CU DATE REVISION OF REVISION Sept 2002 Dec 2005 May

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged, for aluminium based conductors... 63 Suspension clamp trunnion type, forged, with bigger angle

More information

HIGH-VOLTAGE TRANSMISSION AND DISTRIBUTION LINE FITTINGS FOR kv

HIGH-VOLTAGE TRANSMISSION AND DISTRIBUTION LINE FITTINGS FOR kv GLOBAL INSULATOR GROUP tel +371-676-51117 e-mail: ved@gig-group.com www.gig-group.com HIGH-VOLTAGE TRANSMISSION AND DISTRIBUTION LINE FITTINGS FOR 35 1150 kv Products catalogue 2019 contents About the

More information

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE The hardware fittings suitable for tension string to be used for 11KV consisting of following

More information

Bolted Dead End for OPGW

Bolted Dead End for OPGW Bolted Dead End for OPGW The AFL Dead End is a full tension termination for Optical Ground Wire cable. Breakaway head bolts are used to apply a precise gripping force to hold the cable without affecting

More information

TRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors

TRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors TRANSMISSION LINE REPAIR MANUAL A guidebook for the inspection and repair of damaged or worn conductors August 2017 PREFACE Since 1947 Preformed Line Products has been a recognized leader in the business

More information

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary 14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching

More information

OVERHEAD CONSTRUCTION MANUAL

OVERHEAD CONSTRUCTION MANUAL OVERHEAD CONSTRUCTION MANUAL Section Materials Quick Reference Approved by: A Smith-de Pere Energex Limited 214 ABN 4 78 849 55 DOCUMENT NUMBER: 492-A4 LAST UPDATE: 27/2/214 APPLE 6/113. 8372 APPLE 6/113.

More information

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79 73 Contents General.................................................................................................. 74 Wedge tension clamp without jumper guide, for aluminium based conductors...........................

More information

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor INS-ACA089 Installation Instructions Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor 1. Mark the conductor a distance of 3 /4 the length

More information

Section 5 Fiber Optics: FIBERLIGN Hardware for OPGW

Section 5 Fiber Optics: FIBERLIGN Hardware for OPGW FIBERLIGN Hardware for OPGW: Section Section Fiber Optics: FIBERLIGN Hardware for OPGW Table of Contents Page Fiber Optic Product Layout for OPGW...-2 FIBERLIGN ead-end for OPGW...-3 FIBERLIGN Formed Wire

More information

Disconnect & ByPass Switches

Disconnect & ByPass Switches Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class

More information

Fiberglass Construction Products

Fiberglass Construction Products 12 Fiberglass Construction Products Catalog 12 Page 12-1 Fiberglass Construction Products Standoff Brackets With over 50 years of experience in manufacturing Chance Fiberglass Rod polymer insulation products,

More information

16 - Swivels & Joining Links

16 - Swivels & Joining Links 16 - Swivels & Joining inks Quicklinks - Stainless Stainless "C" inks 316 grade stainless steel. n alternative to shackles or snaps allowing quick entry via a threaded hexagon locking nut. S 1 R S S..

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

Dulhunty Industries Pty. Ltd. founded in 1991 and Dulhunty Engineering (China) Ltd. founded in 1996

Dulhunty Industries Pty. Ltd. founded in 1991 and Dulhunty Engineering (China) Ltd. founded in 1996 Dulhunty Industries Pty. Ltd. founded in 1991 and Dulhunty Engineering (China) Ltd. founded in 1996 Acquired by AIL in 2003 and listed on Australian Stock Exchange Locations: Sydney, Australia Yangzhou,

More information

SECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

SECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS 03.00 GENERAL CONSTRUCTION NOTES PRIMARY CONSTRUCTION PRIMARY CONSTRUCTION PIN INSULATOR INSTALLATION 03.00-02 03.00-04 03.00-20 03.02 CONNECTORS AUTOMATIC SPLICE INSTALLATION 03.02-01 INSTALLATION GUIDE

More information

ARMOR-GRIP Suspension: Double

ARMOR-GRIP Suspension: Double : Double For Line Angles Between 30 and 60 ACSR, All-Aluminum, Aluminum Alloy, AWAC Compacted All-Aluminum Compacted ACSR, ACSS, ACSS/TW Range AGS s AGS AGS s & Min. Max. Nominal Conductor Size s Per Set

More information

TRELLEBORG ENGINEERED PRODUCTS. Electrical Safety Products

TRELLEBORG ENGINEERED PRODUCTS. Electrical Safety Products Electrical Safety Products Highest standard of protection. A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg specifically

More information

VORTX Vibration Damper

VORTX Vibration Damper Product Identification 1 2 3 5 4 NOMENLTURE 1. lamp & Keeper: The lamp has an extruded hook shaped profile to hang onto the cable or conductor while tightening the keeper. Together, the aluminum keeper

More information

Product Specifications PIPE SUPPORT PRODUCTS

Product Specifications PIPE SUPPORT PRODUCTS Product Specifications PIPE SUPPORT PRODUCTS For the most up to date information visit our website: www.taylorassociates.com 1 PICTORIAL INDEX FIG. 41 Page 8 FIG. 41 PVC Page 9 Fig. 42 Page 10 FIG. 43

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

OVERHEAD DESIGN MANUAL

OVERHEAD DESIGN MANUAL OVERHEAD DESIGN MANUAL Section 4 Poletop Constructions Approved by: F ZAINI ENERGEX 2018 MANUAL 00302 CONSTRUCTION SELECTION General Notes 1. Constructions should be selected according to: spanning and

More information

00000 Series Clevis Pin Slotted Hexagon Hex Key Recommended Corresponding Part No. Part No. Size Torque Preload SLT* SLT* HEX

00000 Series Clevis Pin Slotted Hexagon Hex Key Recommended Corresponding Part No. Part No. Size Torque Preload SLT* SLT* HEX 00000 Series Clevis Pin All clevis pins are manufactured from heat treated 416 stainless steel to provide superior strength and wear. Hardness is between 37-40 Rc. The DCD Clevis Pin is a shouldered type

More information

Distribution networks : Low Voltage Aerial Cables

Distribution networks : Low Voltage Aerial Cables Distribution networks : Low Voltage Aerial Cables Energy Infrastructures Generation Transmission - Distribution 050804 Nexans LV ABC & Accessories PK 2 Distribution networks : Low Voltage Aerial Bundled

More information

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2

More information

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole 1 L.T Stay set Complete Set 5 2 7/12 GI stay wire kg 50 3 Concreting of stay NO 5 4 Stay clamp

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

Chapter 1. Connectors & Fittings for Railways

Chapter 1. Connectors & Fittings for Railways Chapter Connectors & Fittings for Railways Current Carrying Catenary Dropper Component N Messenger Bz Cable length from L Component N 3 Component N 2 Contact Wire SNCF approved This dropper provides a

More information

INSULATORS.

INSULATORS. S www.transnet.co.nz WARRANTY Connectivity offer a year manufacturing warranty on all branded Porcelain Insulators up to 66kV. In the event a insulator from this range is found to demonstrate manufacturing

More information

TEKNISK RIKTLINJE TR05-10E

TEKNISK RIKTLINJE TR05-10E Notes Change notes Date 1 (A) Revision of standards and new template 09 / 07 2010 2 Template changed.clause. 10.5.1.4 support clamp inserted. Clause 10.5.4.2 creepage text revised. Clause 10.6.7 Dry inserted

More information

Volume-III : Section-I 370 Technical Specifications

Volume-III : Section-I 370 Technical Specifications Volume-III : Section-I 370 TECHNICAL SPECIFICATION-PIERCING INSULATOR 5.1 Insulation Piercing Connectors (IPC) 5.1.1 Insulation Piercing Connectors (IPC) are used for making Tee/Tap-off/Service connectors

More information

August THERMOLIGN Products for CTC ACCC Conductor

August THERMOLIGN Products for CTC ACCC Conductor August 2017 THERMOLIGN Products for CTC ACCC Conductor History of THERMOLIGN Hardware at PLP Preformed Line Products has been involved with the design, testing and production of hardware and accessories

More information

3.0OVERHEAD TRANSMISSION SWITCHES

3.0OVERHEAD TRANSMISSION SWITCHES HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 3 Overhead Transmission Switches CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

Annexure B (1)- Engineering Instructions for Installation of Aerial OFC

Annexure B (1)- Engineering Instructions for Installation of Aerial OFC Annexure B (1)- Engineering Instructions for Installation of Aerial OFC INSTALLATION PRACTICE OF SELF SUPPORTING METAL FREE AERIAL OPTICAL FIBER CABLE 1. SCOPE: This Engineering Instruction (EI) deals

More information

SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE

SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE The hardware fittings suitable for tension string to be used for 11KV / 22 KV consisting of following components.

More information

Power System Analysis I TRANSMISSION LINE PARAMETERS

Power System Analysis I TRANSMISSION LINE PARAMETERS Power System Analysis I TRANSMISSION LINE PARAMETERS Components of Overhead Lines Transmission Line Parameters An overhead transmission line consists of conductors, insulators, support structures, and,

More information

Catalog 14A January 2013

Catalog 14A January 2013 Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

TM OUR PRODUCTS INDIA Accurate, reliable and free from any defect, we provide the best quality Electrical Porcelain and Polymer Insulators, Hardware Fittings and protection Switches at an economical price.

More information

URD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail

URD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail Part 5 LV Underground Drawing Register Number U8 U9 Description URD Mini Pillar Installation Guide UDS Universal Pillar Installation Guide U10-1 UDS Universal Pillar Double Link Unit Drilling Detail U10-2

More information

TOP-PRIORITY TREATMENT WHEN IT MATTERS MOST

TOP-PRIORITY TREATMENT WHEN IT MATTERS MOST TOP-PRIORITY TREATMENT WHEN IT MATTERS MOST Insulators Line Hardware and Conductor Accessories Substation Equipment INSULATORS We partner with the world's best Mosdorfer Graph offers a wide collection

More information

Product Specifications PIPE SUPPORT PRODUCTS. For the most up to date information visit our website:

Product Specifications PIPE SUPPORT PRODUCTS. For the most up to date information visit our website: Product Specifications PIPE SUPPORT PRODUCTS For the most up to date information visit our website: www.taylorpipesupports.ca PICTORIAL INDEX FIG. 41 Page 1 FIG. 41 PVC Page 2 FIG. 43 Page 3 FIG. E31 Page

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17453-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.07.2017 to 02.07.2022 Holder of certificate: SPIE

More information

Suspension Clamps. performance

Suspension Clamps. performance Suspension Clamps performance Suspension Clamps Index olted/aluminum CFS... Corona Free Clamp for Use With Armor Rods...-3 CFS (ONG)... Corona Free Clamp for Use Without Armor Rods...-4 CFSHT... Corona

More information

Wire rope accessories. 5. Wire rope accessories. Index

Wire rope accessories. 5. Wire rope accessories. Index Wire rope accessories 5. Wire rope accessories 1 General 1.1 About Hendrik Veder Group 1.2 Trade names 1.3 Certified Quality 1.4 Certificates 1.5 Key suppliers & brands 1.6 Contact information 1.7 Locations

More information

BRACKETS, MOUNTS & HARDWARE

BRACKETS, MOUNTS & HARDWARE HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips Tough and dependable, Woodhead cable grips and cord grip bodies are reliable workhorses in any plant environment. They serve as flexible holding devices used to pull cable, rope, or tubing into place,

More information

WARRANTY TERMS AND CONDITIONS OF SALE

WARRANTY TERMS AND CONDITIONS OF SALE WARRANTY Products manufactured by Coastal Line Products (CLP) are warranted to be of good workmanship and material for a period of three years from date of delivery. This warranty applies only to products

More information

Product catalogue. Mechanical accessories for pumps and mixers

Product catalogue. Mechanical accessories for pumps and mixers Product catalogue Mechanical accessories for pumps and mixers Contents Mixer accessories Single guide bar system...4 Double/tripod guide bar system...9 Cantilever system...14 Bottom fixing plate system...15

More information

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 32000 GL 80 32002 GL 84 3999 GL 0 32004 GL 4 3200 GL 5 32003 GL 38

More information

When power interruptions happen.

When power interruptions happen. When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage

More information

GSA Series Formed Wire Suspension

GSA Series Formed Wire Suspension GSA Series Formed Wire Suspension Formed Wire Suspension Unit AFL is a renowned manufacturer of aluminum conductor accessories, manufacturing numerous products for the electric utility industry since the

More information

Jumpers & Load Pickup Tools

Jumpers & Load Pickup Tools Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV

More information

Conwire Pty Limited Unit 10/14 Sheridan close Milperra nsw 2214

Conwire Pty Limited Unit 10/14 Sheridan close Milperra nsw 2214 o n w i r e o n t r o l a b l e s Conwire Pty Limited Unit 10/14 Sheridan close Milperra nsw 2214 May 2007 Conwire pty limited A.B.N. 96 138 449 948 Ph: (02) 9774 2155 Unit 10 / 14 SHERIDAN CLOSE, MILPERRA

More information

Quintas & Quintas Group

Quintas & Quintas Group Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors

More information

Wire Management Products Index

Wire Management Products Index Section T Wire Management Products Index Product Page Number Kellems Wire Mesh Grips T-2 3 Pulling Grips T-4 16 DUA-PULL Grips T-6 DUA-PULL Feed Tube T-6 Overhead Multiple Strength T-7 Underground Pulling

More information

Overhead Products. Overhead Products Introduction. Model Q Lasher. Eagle Lasher Series Series

Overhead Products. Overhead Products Introduction. Model Q Lasher. Eagle Lasher Series Series Introduction In 2006, DCD Design took on the Spinning Equipment Company and began producing the Lineman and Eagle cable lashers. In doing so, DCD took on a long history of quality and innovation. These

More information

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 3 Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 1 Contents Installation Guidelines and Maintenance for ACCR Aluminum Conductor Composite Reinforced 1. Introduction 4 2.

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION PRODUCT P 1 / 15 Model No. Description HR2455 Rotary Hammer 24mm (15/16") L W CONCEPT AND MAIN APPLICATIONS Model HR2455 has been developed as a sister tool to Model HR2450, the Makita

More information