Quintas & Quintas Group

Size: px
Start display at page:

Download "Quintas & Quintas Group"

Transcription

1 Electric Conductors

2 Quintas & Quintas Group

3 Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors Steel Reinforced for overhead lines 5 Optical Ground Wire (OPGW) for overhead lines 6 Insulated Cabes uminium Low Voltage Aerial Bundled Conductors 7 uminium or Copper Low Voltage Cables 8 uminium or Copper Medium Voltage Cables 9 uminium Medium Voltage Aerial Bundled Cables 10 uminium or Copper High Voltage Cables 11 uminium or Copper High Voltage Cables (cont.) 12 The values and other characteristics stated and this catalogue must be considered as indicative ones. For other cross sections, service voltages or particular details, please contact our services.

4 Quintas & Quintas and Solidal Quintas & Quintas Condutores Eléctricos SA. and Solidal Condutores Eléctricos, SA, leaders in the industry of the aluminium power conductors have as principal activity the production of bare and insulated electric conductors, their coercialization and the technical support with the assembly of the provided products. Quintas Condutores in the sector of bare electric conductors and Solidal in the insulated cables, their productions are mainly directed on aluminium products. This market segment, appeared, these last years, strongly challenging, which is mainly due to the increasing aggressiveness from the manufacturing companies. However, Quintas Condutores in the market of bare cables and Solidal in insulated cables are leaders of the sector. The two companies followed a strategy based on two orientations: to carry out a progressive vertical integration, increasing, thus, the level of the added value of the products that they sell and to remain updated from the technological point of view, while they invest regularly in advanced technology equipment and productivity and simultaneously in Technical Boards of recognized rename and their adequate formation. Nowadays Quintas & Quintas and Solidal have all the equipment and know-how necessary to the industrial process, to produce and transform the conductors indicated hereafter: Quintas & Quintas. Bare uminium cables: Solid conducting conductors, round form or sectoral; Conducting conductors multiwire, round form or sectoral.. Cables for Bare Aerial lines: uminium cables AAAC (l uminium Conductors); uminium alloy cables AAAC (l uminium loy Conductors); uminium cables with alloy ACAR conductor (uminium Conductors loy Reinforced); uminium cables with steel ACSR conductor (uminium Conductors Steel Reinforced); uminium cables with ACS ACSR/AW conductor (uminium Conductors ACS Reinforced); loy cables with steel AACSR conductor (uminium loy Conductors Steel Reinforced); Guard cables with optical fibre OPGW (Optical Power Ground Wire). Solidal. Insulated cables: The production in the sector of insulated conductors covers the range of the aerial and underground cables of Low, Medium and High Voltage. Main conductor types: Low Voltage Cables (0,6/1 kv) - Sections of 16 2 up to (with rigid conductors, multiwire, round or sectoral, of aluminium) - Sections of 54,6 and 80 2 (with conductors multiwire, of aluminium alloy, melec) Medium Voltage Cables (6 to 36 kv) - Sections of 35 2 up to insulated with dielectric extruded solid, by triple simultaneous extrusion, with conducting conductors multiwire of aluminium or copper, with reticulation in atmosphere of inert gas. High Voltage Cables (up to 150 kv) - Sections of up to insulated with the dielectric extruded solid, in triple simultaneous extrusion, with conducting conductors multiwire of aluminium or copper, possibly with elements of stuffing of longitudinal and radial sealing, with reticulation in an dry atmosphere. The aluminium used in the manufacture of the cables has a high degree of purity, never inferior than 99,7%. 2

5 l uminium Conductors for overhead lines Construction: This bare concentric-lay stranded conductor is constructed with a straight round central wire surrounded by one or more layers of helically wires. Applications: The aluminum alloy cables are used normally in overhead lines. Standards: EN ; EN Electrical and dimensional characteristics of uminum Conductors AL1 Designation Area Diameter () Mass per unit length Rated strength DC resistance at 20 0 C Final Modulus of Elasticity Coefficient of linear Expansion Code Old code 2 wire Cond. kg/km kn /km N/ 2 1/K A 25-AL1 25/ , E Continuous loading capacity (1) 34-AL1 35/ E AL1 50/ E AL1 70/ E AL1 95/ E AL1 120/ E AL1 240/ E AL1 500/ E AL1 800/ E Note: Direction of lay of external layer is right-hand (Z). (1) - Reference values valid up to 50 Hz at a wind speed of 0,6 m/s and solar irradiation giving an initial ambient temperature of 35 C and a final conductor temperature of 80 C. Compositions 7 wires 19 wires 37 wires 61 wires 3

6 l uminium loy Conductors for overhead lines Construction: This bare concentric-lay stranded conductor is constructed with a straight round central wire surrounded by one or more layers of helically wires. Applications: Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. uminum alloy gives AAAC higher resistance to corrosion than ACSR. Standards: EN ; EN Electrical and dimensional characteristics of uminum loy Conductors - AL3 Designation Area Diameter () Mass per unit length Rated strength DC resistance at 20 0 C Final Modulus of Elasticity Coefficient of linear Expansion Code Old code 2 loy wire Cond. kg/km kn /km N/ 2 1/K A 35-AL3 35/ E Continuous loading capacity (1) 49-AL3 50/ E AL3 70/ E AL3 95/ E AL3 120/19 125, E AL3 150/ , E AL3 185/ E AL3 200/ E AL3 240/ , E AL3 300/61 304, E AL3 400/ , E Note: Direction of lay of external layer is right-hand (Z). (1) - Reference values valid up to 50 Hz at a wind speed of 0,6 m/s and solar irradiation giving an initial ambient temperature of 35 C and a final conductor temperature of 80 C. Compositions 7 wires 19 wires 37 wires 61 wires 4

7 uminum Conductors Steel Reinforced for overhead lines Construction: ACSR is a concentrically stranded conductor composed of one or more layers of aluminum wire stranded with a high strength coated steel core. The core may be single wire or stranded depending on the size. The proportions of aluminum and steel can be varied to obtain the relation between current-carrying capacity and mechanical strength best suited to each application. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease. Applications: Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. Standards: EN ; EN ; EN Electrical and dimensional characteristics of uminum Conductors Steel Reinforced - AL1/ST1A Code Designation Areas ( 2 ) Wire Diameter () Diameter () Old code Steel Total Steel Steel Core Cond. Mass per unit length Rated strength kg/km kn DC resistance at 20 C /km Final Modulus of Elasticity N/ 2 Coefficient of linear Expansion 1/K 42-AL1/7-ST1A 42/6+1 42,4 7,1 49, ,00 3,00 3,00 9,00 171,2 15,27 0, ,6E AL1/39-ST1A 68/ ,7 39,5 107, ,68 2,68 8,04 13,40 495,8 56,52 0, ,3E AL1/21-ST1A 128/ ,6 20,9 148, ,50 1,95 5,85 15, ,79 0, ,6E AL1/31-ST1A 191/ ,2 31,1 222, ,06 2,38 7,14 19,4 771,6 67,05 0, ,9E AL1/49-ST1A 212/ ,1 49,5 261, ,00 3,00 9,00 21,0 973,1 92,46 0, ,9E AL1/43-ST1A 265/ ,6 43,1 307, ,60 2,80 8,40 22, ,48 0, ,9E AL1/79-ST1A 349/ ,2 78,9 428, ,85 2,30 11,50 26,9 1585,7 145,87 0, ,0E AL1/49-ST1A 382/ ,7 49,5 431, ,00 3,00 9,00 27,0 1442,5 121,3 0, ,4E AL1/93-ST1A 416/ ,6 93,3 508, ,20 2,50 12,50 29,3 1881,8 172,82 0, ,0E AL1/56-ST1A 434/ ,3 56,3 490, ,20 3,20 9,60 28,8 1641,3 133,59 0, ,4E AL1/66-ST1A 520/ ,5 65,8 585, ,50 2,10 10,50 31,5 1952,1 162,72 0, ,5E AL1/79-ST1A 629/ ,6 78,9 707, ,85 2,30 11,50 34,6 2356,6 190,58 0, ,5E AL1/93-ST1A 748/ ,1 93,3 841, ,20 2,50 12,15 37,7 2799,3 226,03 0, ,5E AL1/109-ST1A 858/ ,8 108,8 967, ,50 2,70 13,50 40,5 3226,9 261,43 0, ,5E Continuous loading capacity (1) A Note: Direction of lay of external layer is right-hand (Z). (1) - Reference values valid up to 50 Hz at a wind speed of 0,6 m/s and solar irradiation giving an initial ambient temperature of 35 C and a final conductor temperature of 80 C. Compositions 6/1 wires 12/7 wires 26/7 wires 30/7 wires 54/7 wires 5

8

9 uminium Low Voltage Aerial Bundled Conductors Voltage 0,6/1 kv Construction: Round stranded and compacted aluminium conductors (phases/neutral). uminium alloy messengers (neutral conductor) in several cross sections, namelly 54,6, 70, 80 and 95 2 can also be included in the bundle. XLPE Insulation, UV resistant Applications: The aluminium aerial bundled conductors are mainly used for the low voltage distribution networks, namely in the rural or suburban areas, due to several specific advantages, like: - good network performance (low failure rate) - possibility to perform repairs and interventions in the lines under tension - reduced installation cost - reduced forest fire risk - particulary suitable for heavily polluted environments - good resistance to acid rain salt spray Standards: HD 626 S1; NFC Electrical and dimensional characteristics of the Aerial Bundled Conductors Designation Diameter of conductor (aprox.) Phase Neutral Insulation thickness Phase Neutral Diameter on insulation (aprox.) Phase Neutral Bundle Diameter (aprox.) Weight (aprox. DC resistance at 20º0 C Phase Neutral rrent Rating (1) Voltage drop cos = 0,8 2 kg/km /km A V/A.km Aerial Bundled Aerial Bundled (uminium alloy neutral) 2x16 4,8 4,8 1,2 1,2 7,4 7,4 14, ,91 1, ,98 2x16+2x1,5 4,8 4,8 1,2 1,2 7,4 7,4 16, ,20 1, ,98 2x25 6,0 6,0 1,4 1,4 9,0 9,0 18, ,91 1, ,54 2x25+2x1,5 6,0 6,0 1,4 1,4 9,0 9,0 20, ,20 1, ,54 4x16 4,8 4,8 1,2 1,2 7,4 7,4 17, ,91 1, ,44 4x16+2x1,5 4,8 4,8 1,2 1,2 7,4 7,4 19, ,91 1, ,44 4x25 6,0 6,0 1,4 1,4 9,0 9,0 21, ,20 1, ,20 4x25+2x1,5 6,0 6,0 1,4 1,4 9,0 9,0 23, ,20 1, ,20 3x35+54,6 7,0 9,5 1,6 1,6 10,4 10,4 33, ,868 0, ,65 3x35+54,6+1x16 7,0 9,5 1,6 1,6 10,4 10,4 33, ,868 0, ,65 3x35+54,6+2x16 7,0 9,5 1,6 1,6 10,4 10,4 33, ,868 0, ,65 3x35+54,6+3x16 7,0 9,5 1,6 1,6 10,4 10,4 33, ,868 0, ,65 3x70+54,6 9,8 9,5 1,8 1,6 13,6 13,2 38, ,443 0, ,87 3x70+54,6+1x16 9,8 9,5 1,8 1,6 13,6 13,2 38, ,443 0, ,87 3x70+54,6+2x16 9,8 9,5 1,8 1,6 13,6 13,2 38, ,443 0, ,87 3x70+54,6+3x16 9,8 9,5 1,8 1,5 13,6 13,0 38, ,443 0, ,87 3x ,8 10,2 1,8 1,5 13,6 13,0 41, ,443 0, ,87 3x x16 9,8 10,2 1,8 1,5 13,6 13,0 41, ,443 0, ,87 3x x16 9,8 10,2 1,8 1,5 13,6 13,0 41, ,443 0, ,87 3x x16 9,8 10,2 1,8 1,5 13,6 13,0 41, ,443 0, ,87 3x ,5 10,2 1,7 1,5 18,1 17,7 48, ,206 0, ,46 3x x16 14,5 10,2 1,7 1,5 18,1 17,7 48, ,206 0, ,46 3x x16 14,5 10,2 1,7 1,5 18,1 17,7 48, ,206 0, ,46 3x x16 14,5 10,2 1,7 1,5 18,1 17,7 48, ,206 0, ,46 (1) The maximum beareable current values are refered to the following condictions: - Permanent working condictions - Temperature of in open air 30 C Rating Factors: Ambient air temperature Coefficient 1,17 1,13 1,09 1,04 1,00 0,95 0,91 0,85 0,8 0,67 0,52 7

10 uminium or Copper Low Voltage Cables Construction: uminium conductors (solid/stranded, round/sector shaped) XLPE insulation. Polyester assembling tape PVC bedding (armoured cables) Double helix tape (multi core armoured cables) or aluminium tape (single core cables) PVC outer sheath (LDPE sheath supplied on request) Applications: Power plants, underground distribution networks, industrial plants. The solid conductor cables are particulary suitable for the low voltage circuits, between the transformers and main distribution boards. The cables can be installed in ducts or open air (the armoured versions are generally used in undergruond circuits, directly buried in the soil). Voltage 0,6/1 kv Standards: HD 603 S1; IEC Electrical and dimensional characteristics of Low Voltage Cables Designation Diameter of conductor Insulation thickness Phase Neutral Diameter on insulation Diameter of cable Weight DC resistance at 20 0 C rrent Rating (1) air underground Voltage drop cos = 0,8 2 kg/km /km A V/A.km 1 Core 3 Cores/Neutral 4 Cores 1x16 4,80 0,7-6,4 9, , ,50 1x25 6,00 0,9-8,0 11, , ,24 1x35 7,00 0,9-9,0 12, , ,65 1x50 8,10 1,0-10,3 13, , ,29 1x70 9,80 1,1-12,2 15, , ,88 1x95 11,40 1,1-13,8 17, , ,66 1x120 13,00 1,2-15,6 18, , ,54 1x150 14,50 1,4-17,5 20, , ,46 1x185 16,40 1,6-19,8 23, , ,38 1x240 18,50 1,7-22,1 25, , ,32 1x300 20,80 1,8-24,6 28, , ,27 1x400 23,60 2,0-27,8 31, , ,22 1x500 26,80 2,2-31,4 35, , ,19 1x630 30,60 2,4-35,6 40, , ,16 3x35/16 7,00 0,9 0,7 9,0 23, , ,63 3x50/25 8,10 1,0 0,9 10,3 26, , ,22 3x70/35 9,80 1,1 0,9 12,2 30, , ,87 3x90/50 11,40 1,1 1,0 13,8 34, , ,65 3x120/70 13,00 1,2 1,1 15,6 37, , ,53 3x150/70 14,50 1,4 1,1 17,5 41, , ,45 3x185/95 16,40 1,6 1,1 19,8 46, , ,37 3x240/120 18,50 1,7 1,2 22,1 52, , ,30 4x35 7,00 0,9 0,9 9,0 23, , ,63 4x50 8,10 1,0 1,0 10,3 26, , ,22 4x70 9,80 1,1 1,1 12,2 30, , ,87 4x95 11,40 1,1 1,1 13,8 34, , ,65 4x120 13,00 1,2 1,2 15,6 38, , ,53 4x150 14,50 1,4 1,4 17,5 41, , ,45 4x185 16,40 1,6 1,6 19,8 46, , ,37 4x240 18,50 1,7 1,7 22,1 52, , ,30 (1) The maximum beareable current values are refered to the following condictions: - Permanent working condictions - Temperature of in open air 30 C - Temperature of the ground 20 C - Depth of installation from 0,70 to 1,0 meter. 8

11 uminium or Copper Medium Voltage Cables Voltage 6/10 (12) kv 12/20 (24) kv 18/30 (36) kv Construction de base: Round stranded and compacted aluminium or copper conductors. Inner semi-conducting layer. XLPE or HEPR insulation. Outer semi-conducting layer (strippable or full bonded ). Metallic screen (copper wires/copper tape). Non-metallic outer sheath (PVC or PE). Construction options: Conductor water blocking (water swellable yarns). Radial water blocking (water swellable tape). uminium tape armoured (single core cables) or steel tape armour (three core cables). Outer sheath: - Halogen free flame retardant - Co-extruded conductive layer over the sheath for special sheath testing Applications: Medium voltage transport and distribution networks, industrial plants, power plants, transformer units, connection between overhead lines and transformers. The cables can be installed in ducts, galleries, directly buried in the soil or in the open air. The armoured versions are particulary suitable to be directly buried in the soil, when an extra mechanical protection is needed. Standards : IEC ; HD 620 Electrical and dimensional characteristics of the Cables (no armoured) Cross section Diameter of conductor Insulation thickness Diameter over insulation Outer Sheath thickness Outer diameter of cable Approx. weight (kg/km) Capacitance C Inductance L Reactance XL Impedance Z 90ºo C ( /km) 2 μf/km mh/km /km Voltage 6/10 kv Voltage 12/20 kv Voltage 18/30 kv 35 7,0 15,9 1,8 22, ,23 0,399 0,125 1,12 0, ,1 17,0 1,8 23, ,25 0,381 0,120 0,83 0, ,8 18,7 1,8 24, ,29 0,362 0,114 0,36 0, ,4 20,3 1,8 26, ,32 0,347 0,109 0,42 0, ,0 21,9 1,8 28, ,35 0,337 0,106 0,34 0, ,5 3,4 23,4 1,9 29, ,38 0,327 0,103 0,28 0, ,4 25,3 1,9 31, ,41 0,320 0,101 0,23 0, ,5 27,4 2,0 33, ,46 0,310 0,097 0,19 0, ,8 29,7 2,1 36, ,50 0,300 0,094 0,16 0, ,6 32,5 2,2 39, ,55 0,290 0,091 0,14 0, ,8 35,7 2,3 42, ,62 0,281 0,088 0,12 0, ,0 20,1 1,8 26, ,17 0,427 0,134 1,12 0, ,1 21,2 1,8 27, ,18 0,411 0,129 0,83 0, ,8 22,9 1,8 29, ,20 0,390 0,123 0,36 0, ,4 24,5 1,9 30, ,22 0,376 0,118 0,43 0, ,0 26,1 2,0 32, ,24 0,366 0,115 0,34 0, ,5 5,5 27,6 2,0 34, ,26 0,355 0,111 0,29 0, ,4 29,5 2,1 36, ,28 0,343 0,108 0,24 0, ,5 31,6 2,1 38, ,31 0,331 0,104 0,19 0, ,8 33,9 2,2 40, ,34 0,320 0,101 0,16 0, ,6 36,7 2,3 43, ,37 0,309 0,097 0,14 0, ,8 39,9 2,4 47, ,41 0,299 0,094 0,12 0, ,0 25,1 1,9 31, ,13 0,462 0,145 1,12 0, ,1 26,2 2,0 32, ,14 0,444 0,140 0,83 0, ,8 27,9 2,0 34, ,16 0,425 0,134 0,37 0, ,4 29,5 2,1 36, ,17 0,407 0,128 0,43 0, ,0 14,5 8,0 31,1 32,6 2,1 2,2 37,8 39, ,19 0,20 0,392 0,380 0,123 0,119 0,35 0,29 0,23 0, ,4 34,5 2,2 41, ,22 0,367 0,115 0,24 0, ,5 36,6 2,3 43, ,23 0,354 0,111 0,20 0, ,8 38,9 2,4 46, ,25 0,342 0,108 0,17 0, ,6 41,7 2,5 49, ,28 0,330 0,104 0,14 0, ,8 44,9 2,6 52, ,31 0,318 0,100 0,13 0,11 Cross Section ( 2 ) DC at 20 0 C ( /km) Resistance AC at 90 0 C ( /km) Underground (1) rrent Rating (A) Voltage Drop (cos = 0,8) V/A.km 35 0,868 0,524 1,113 0, ,68 1, ,641 0,387 0,822 0, ,27 0, ,443 0,268 0,568 0, ,91 0, ,320 0,193 0,411 0, ,69 0, ,253 0,153 0,325 0, ,57 0, ,206 0,124 0,265 0, ,48 0, ,164 0,099 0,211 0, ,40 0, ,125 0,075 0,161 0, ,33 0, ,100 0,060 0,129 0, ,28 0, ,078 0,047 0,101 0, ,24 0, ,061 0,037 0,080 0, ,21 0,17 The currents and voltage drops are indicated for a 3 phase installation (3 cables in trefoil). (1) - Maximum temperature of the ground 20 C; (2) - Maximum temperature in open air 30 C Air (2) 9

12 uminium Medium Voltage Aerial Bundled Cables Construction: Round stranded and compacted aluminium or copper conductor. Inner semi-conducting layer. XLPE insulation. Outer semi-conducting layer (strippable or full bonded ). Metallic screen (copper tape). Non-metallic outer sheath (PE or PVC). Voltage 6/10 (12) kv 8,7/15 (17,5) kv 12/20 (24) kv 18/30 (36) kv Applications: The medium voltage bundled cables are particularly suitable for overhead transport and distribution networks in places were an underground network would be unrealisable (rocky soil, forest and mountain areas). This cables are also frequently used in temporary connections, as they can be easily installed and removed. The overhead bundled cables are also an ideal solition for heavily polluted ar maritime environments, and they resist rather well to frost and low temperatures. Standards: IEC ; HD 620 Electric and Dimensional characteristics of the Cables Cross section Approx. Outer Diameter () Aerial Bundled (1) rrent in open air (1) Voltage drop (1) - Manufacture for 18/30 kv under order. With 50 2 steel covered cable. Other steel wire support sections may be supplied under request. Maximum temperature in open air 30º C. (2) - rrents and voltage drops are indicated for a 3 phase installation. 10

13 uminium or Copper High Voltage Cables Construction: Round stranded and compacted aluminium or copper conductor (longitudinal water sealing). Inner semi-conducting layer. XLPE insulation. Outer semi-conducting layer. Metallic screen (copper wires/copper tape). Longitudinal water sealing of metallic screen. Radial water sealing (-PE laminate or -PE laminate). Non-metallic outer sheath (PE or PVC). - Halogen free flame retardant. - Co-extruded conductive layer over the sheath for special sheath testing. Rated voltage 26/45 kv 36/60 kv 64/110 kv 76/132 kv 87/150 kv Applications: High voltage transport and distribution networks, industrial plants, power plants, transformer units. The cables can be installed in ducts, galleries, directly buried in the soil or in the open air. Standards: IEC 60840; HD 632-S1 Electrical and Dimensional characteristics of the Cables Cross section of conductor Diameter of conductor Insulation thickness Diameter over insulation Metallic Screen Outer Sheath thickness Outer diameter of cable Cable weight (kg/m) Capacitance C Inductance L Short-circuit condictions ka (1 s) In conductor (1) In metal screen (2) 2 2 μf/km mh/km Voltage 87/150 kv Voltage 76/132 kv Voltage 64/110 kv Voltage 36/60 kv Voltage 26/45 kv ,5 8,0 32,6 35 3,0 43,0 2,1 3,0 0,20 0,38 14,1 21, ,4 8,0 34,5 35 3,0 45,0 2,2 3,4 0,22 0,37 17,4 26, ,5 8,0 36,6 35 3,0 47,0 2,5 4,0 0,23 0,36 22,6 34, ,8 8,0 38,9 35 3,0 49,0 2,8 4,6 0,25 0,34 28,2 42, ,6 8,0 41,7 35 3,0 52,0 3,1 5,5 0,28 0,33 37,6 57,2 5, ,8 8,0 44,9 35 3,0 55,0 3,5 6,6 0,31 0,32 47,0 71, ,6 8,0 48,7 35 3,0 59,0 4,1 8,0 0,34 0,31 59,2 90, ,7 8,0 52,8 35 3,0 63,0 4,8 9,7 0,37 0,30 75,2 114, ,3 8,0 57,4 35 3,0 68,0 5,5 11,7 0,41 0,29 94,0 143, ,5 9,0 35,0 35 3,0 46,0 2,2 3,1 0,19 0,39 14,1 21, ,4 9,0 36,9 35 3,0 48,0 2,4 3,5 0,20 0,38 17,4 26, ,5 9,0 39,0 35 3,0 50,0 2,6 4,1 0,22 0,37 22,6 34, ,8 9,0 41,3 35 3,0 52,0 2,9 4,7 0,24 0,35 28,2 42, ,6 9,0 44,1 35 3,0 55,0 3,2 5,6 0,26 0,34 37,6 57,2 5, ,8 9,0 47,3 35 3,0 58,0 3,7 6,7 0,28 0,33 47,0 71, ,6 9,0 51,1 35 3,0 62,0 4,2 8,2 0,31 0,32 59,2 90, ,7 9,0 55,2 35 3,0 66,0 4,9 9,8 0,34 0,31 75,2 114, ,3 9,0 59,8 35 3,0 71,0 5,6 11,8 0,38 0,30 94,0 143, ,4 16,0 51,3 95 3,5 65,0 4,1 5,2 0,14 0,44 17,4 26, ,5 15,0 51,4 95 3,5 65,0 4,2 5,7 0,16 0,41 22,6 34, ,8 14,0 51,7 95 3,5 65,0 4,4 6,2 0,17 0,39 28,2 42, ,6 14,0 54,5 95 3,5 68,0 4,8 7,1 0,19 0,38 37,6 57, ,8 14,0 57,7 95 3,5 71,0 5,3 8,4 0,20 0,37 47,0 71,5 14, ,6 14,0 61,5 95 4,0 76,0 6,0 9,9 0,22 0,35 59,2 90, ,7 14,0 65,6 95 4,0 80,0 6,7 11,7 0,24 0,34 75,2 114, ,3 14,0 70,2 95 4,0 85,0 7,6 13,7 0,27 0,33 94,0 143, ,5 14,0 74,4 95 4,0 89,0 8,4 16,1 0,29 0,32 112,8 171, ,0 14,0 81,9 95 4,0 97,0 10,1 20,2 0,33 0,31 150,4 228, ,5 18,0 57,4 95 4,0 72,0 4,9 6,4 0,14 0,44 22,6 34, ,8 17,0 57,7 95 4,0 72,0 5,1 6,9 0,15 0,41 28,2 42, ,6 16,0 58,5 95 4,0 73,0 5,3 7,6 0,17 0,39 37,6 57, ,8 16,0 61,7 95 4,0 76,0 5,8 8,9 0,19 0,38 47,0 71,5 14, ,6 16,0 65,5 95 4,0 80,0 6,4 10,4 0,20 0,37 59,2 90, ,7 16,0 69,6 95 4,0 84,0 7,2 12,1 0,22 0,35 75,2 114, ,3 16,0 74,2 95 4,0 89,0 8,1 14,3 0,24 0,34 94,0 143, ,5 16,0 78,4 95 4,0 93,0 9,0 16,7 0,26 0,33 112,8 171, ,0 16,0 85,9 95 4,0 101,0 10,6 20,7 0,29 0,32 150,4 228, ,6 20,0 67,1 95 4,0 82,0 6,2 8,5 0,15 0,41 37,6 57, ,8 19,0 68,3 95 4,0 84,0 6,5 9,6 0,17 0,40 47,0 71, ,6 18,0 70,1 95 4,0 85,0 6,9 10,8 0,19 0,37 59,2 90, ,7 18,0 74,2 95 4,0 89,0 7,7 12,7 0,21 0,36 75,2 114,4 14, ,3 18,0 78,8 95 4,0 94,0 8,6 14,8 0,22 0,35 94,0 143, ,5 18,0 83,0 95 4,0 98,0 9,5 17,2 0,24 0,34 112,8 171, ,0 18,0 90,5 95 4,0 106,0 11,2 21,3 0,27 0,32 150,4 228,8 (1) Values calculated according to IEC 949 based on a conductor temperature of 90 C. (2) Values calculated according to IEC 949 based on a metallic screen temperature of 70 C before short-circuit. 11

14 uminium or Copper High Voltage Cables (cont.) Characteristics of installation of the Cables: - Ambient air temperature: 30 0 C - Laying depth: 1,2 m - Ground temperature: 20 0 C - Ground thermal resistivity: 1,2 0 K.m/W Characteristics of use of the Cables: - Permissible short circuit temperature: C - Permissible operating temperature : 90 0 C - Permissible screen temperature: 70 0 C rrent Rating for XLPE Cable Systems (A) Trefoil formation Cross section conductor Cables in Ground Cables in Air Mise à la terre des l écrans Cross Bonded Cross Bonded Cross Bonded Both ends C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C Rated voltage kv Rated voltage kv Rating Factors: Laying depth, m Rating factor Ground temperature, 0 C Conductor temperature, 0 C ,50 1,12 0,70 1,07 0,90 1,07 1,00 1,02 1,20 1,00 1,50 0, ,07 1,04 1,00 0,96 0,93 0,89 0,84 0,8 65 1,11 1,05 1,00 0,94 0,88 0,82 0,74 0,66 Ambient air temperature, 0 C Air temperature, 0 C Factor 1,18 1,13 1,10 1,05 1,00 0,95 0,90 0,85 12 d Ground thermal resistivity Thermal resistivity, 0 Km/W 0,7 1,0 1,2 1,5 2,0 2,5 3,0 Factor 1,23 1,08 1,00 0,9 0,8 0,72 0,66 Number of groups Distance d between groups, ,00 0,76 0,67 0,59 0,55 0,51 0,49 0, ,00 0,81 0,71 0,65 0,61 0,49 0,56 0, ,00 0,85 0,77 0,72 0,69 0,66 0,64 0, ,00 0,88 0,81 0,77 0,74 0,72 0,71 0,7

15

16

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

XLPE Cable Systems. User s guide. rev. 2

XLPE Cable Systems. User s guide. rev. 2 XLPE Cable Systems User s guide rev. 2 C O N T E N T XLPE Cable Systems Page Page Introduction... 3 XLPE cable systems - design, installation and testing... 4 XLPE cables... Cable accessories... Installation

More information

P High Voltage Catalogue Cables Australia Powering your Project

P High Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated

More information

High Voltage and Extra High Voltage Cables

High Voltage and Extra High Voltage Cables High Voltage and Extra High Voltage Cables GUIDE TO THE SELECTION OF EHV AND HV CABLES EHV and HV cables are specially designed on the basis of the project data. To determine appropriate design of a high

More information

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Medium voltage - Energy RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Structure and electrical, physical, mechanical requirements: CEI 20-13 IEC 60502 Flame propagation: EN 60332-1-2 Measurement of partial

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

MEDIUM VOLTAGE POWER CABLES

MEDIUM VOLTAGE POWER CABLES MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM

More information

XLPE CABLES AND CABLE SYSTEMS KV MODERN SOLUTIONS FOR POWER CABLES/ESTRALIN HVC

XLPE CABLES AND CABLE SYSTEMS KV MODERN SOLUTIONS FOR POWER CABLES/ESTRALIN HVC XLPE CABLES AND CABLE SYSTEMS 66-220 KV MODERN SOLUTIONS FOR POWER CABLES/ESTRALIN HVC XLPE рower cables...2 Production technology...3 Estralin HVC High Voltage cable production pioneer in Russia...4 Products

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable 0.6/1kV - PVC Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS: 1.IEC60502-1;VDE 0276-603 ;ICEA S-95-658 ;AS/NZS 5000.1; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number cores : One core, two cores,

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/

More information

DURAREEL TRAILING REELING CABLE

DURAREEL TRAILING REELING CABLE Supplementary Technical Information Reeling and trailing material characteristics: A. Power core conductor Flexible strands tinned annealed copper complies with AS/NZS 1802, AS/NZS 2802, AS/NZS 1125, and

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

Global data. Electrical parameters

Global data. Electrical parameters ()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

CAAI-S 0,6/1 kv with Public Lighting

CAAI-S 0,6/1 kv with Public Lighting For overhead secundary distribution networks. Description Application: For urban and rural overhead secundary distribution networks, with voltages up to 1000 V. Construction: 1. Conductor: Aluminium 1350,

More information

ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor)

ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor) ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor) The steel reinforced aluminium conductor consists of seven or more aluminium wires applied in concentric layers over a steel core made of one

More information

Company Profile. Caledonian Medium Voltage Cables

Company Profile. Caledonian Medium Voltage Cables Caledonian Medium Voltage Cables Company Profile Caledonian develops, manufactures and markets a totally integrated product line of Medium Voltage Cables for a diverse variety of technological applications.

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Linking the Future As the worldwide leader

More information

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable 0.6 / 1kV XLPE Insulated Unarmoured Cables 0.6 / 1kV XLPE Insulated Armoured Cables 1.8 / 3kV XLPE Insulated Armoured Cables 3.6 / 6kV

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power System Analysis I TRANSMISSION LINE PARAMETERS

Power System Analysis I TRANSMISSION LINE PARAMETERS Power System Analysis I TRANSMISSION LINE PARAMETERS Components of Overhead Lines Transmission Line Parameters An overhead transmission line consists of conductors, insulators, support structures, and,

More information

Medium Voltage Power Cables

Medium Voltage Power Cables Medium Voltage Power s Distribution s (CN s) are suitable for use above ground in open air, in conduit in air, directly buried, in underground duct, or aerially when suspended on a messenger wire. CN cables

More information

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured List of Malaysian Standard (MS) for Cables Prepared by MCMA SWO NO. PUBLICATIONS 1. MS 2100 : 2007 2. MS 2101 : 2007 3. MS 2102 : 2007 4. MS 2103 : 2007 5. MS 2104 : 2007 6. MS 2105 : 2007 7. MS 2106 :

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 08-0-6 Page o : Of 5 LST OF PUBLSHED STDRDS Total Count: 78 umber SS umber pproved mendment SBS/TC 066 SS 97:07 7.0 Electric cables - mpregnated paper-insulated 07-0-7 metal-sheathed cables for

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

Submarine Power Cables

Submarine Power Cables Submarine Power Cables Submarine Power Cables Since decades Nexans plant in Hannover is specialised in the design, production and installation of low and medium voltage submarine power cables required

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date Last Amended on - Page 1 of 6 I. CABLES AND ACCESSORIES 1. PVC Insulated Cables Tests on Conductor: Annealing Test (copper) IS 10810 (Part 1):1984 (RA 2011) 0 to 50 % Tensile Test (Aluminium) IS 10810

More information

North America HIGH&EXTRA-HIGH VOLTAGE UNDERGROUND SOLUTIONS

North America HIGH&EXTRA-HIGH VOLTAGE UNDERGROUND SOLUTIONS North America HIGH&EXTRA-HIGH VOLTAGE UNDERGROUND SOLUTIONS WELCOME On-Line Catalog Features Join the Wire Wizard for a quick, informative tour showing the interactive features of our catalogs View the

More information

LOW VOLTAGE c a b l e s

LOW VOLTAGE c a b l e s LOW VOLTAGE c a b l e s MYSORE PLANT SILVASSA PLANT MANUFACTURES A RANGE OF LOW VOLTAGE CABLES AT ITS FACILITIES AT SILVASSA AND MYSORE The Silvassa unit manufactures LV Cables since the year 2000. XLPE/

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

AERIAL. a Nexans company. Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone Cable Sales Phone 1300 CABLES

AERIAL. a Nexans company. Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone Cable Sales Phone 1300 CABLES Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone 613 9281 4444 Cable Sales Phone 1300 CABLES New Zealand Paraite Road Bell Block New Plymouth New Zealand Phone 646 755 9800

More information

Standardization IEC /-351/-353. Conductor material

Standardization IEC /-351/-353. Conductor material Low voltage power cables Fire resistant low voltage power cables according to the new demanding IEC -60331 1/2 specifications for power and lighting applications in all ship areas, with reduced diameter

More information

Medium voltage cables

Medium voltage cables Medium voltage cables Leading producer of cables and cable systems 2 The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years. A stable

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

Medium Voltage Cable. marmonutility.com

Medium Voltage Cable. marmonutility.com Medium Voltage marmonutility.com Table Contents Introduction... 2 Hendrix Product Information... 4 Distribution s (URD) 15kV...6 25kV... 10 35kV...12 28kV...14 Electrical Data...16 Kerite Product Information...

More information

Pyrohalon. Cables, halogen-free, fire-retardant. Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant

Pyrohalon. Cables, halogen-free, fire-retardant. Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant Pyrohalon Cables, halogen-free, fire-retardant www.oktechnology.ru w Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant Disappointing statistics Fire is a great disaster that often cause

More information

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation 2 17 BUIS_003.tif 2 18 BUIS_004.tif Selection and dimensioning criteria Refer to Section 4 for further details

More information

Technical Information

Technical Information Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

EARTH WIRE FITTINGS 08

EARTH WIRE FITTINGS 08 EARTH WIRE FITTINGS 08 8 EARTH WIRE FITTINGS 119 Contents General... 120 C-bracket... 123 Suspension clamp with bolt, with straps, for steel and copper conductors... 123 Suspension clamp with bolt, with

More information

I N T R O D U C T I O N

I N T R O D U C T I O N I N T R O D U C T I O N GEMSCAB are being manufactured by the people who have been associated with the industry for over years and understand the requirements their valued customers. The company took up

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES * october 2004 TRATOSFLEX 2 Selection of type of cable in relation to use Recommended Bending Radius INDEX Current carrying capacities for continuos operation Current carrying capacities for intermittent

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

Wire. Litz. components need a dependable source for Litz. wire of the highest quality. New England Wire Technologies

Wire. Litz. components need a dependable source for Litz. wire of the highest quality. New England Wire Technologies Litz Wire Litz Wire Manufacturers of electronic components need a dependable source for Litz wire of the highest quality. pioneered and continues to be a leader in the manufacturing of high quality Litz

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

GEMSCAB has been associated with marketing and manufacturing of Electric Cables I NTRODUCTION GEMSCAB has been associated with marketing and manufacturing Electric Cables for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath. Standard Power Cables Low age (600/1000 V) BS5467 Cable Approvals > Cable approved to BS5467 > Pla annealed copper stranded (Class 2) for ease of handlg Insulation > 90 C -lked XLPE sulation complyg with

More information

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE Marine Cables FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for over 165 years, always dedicated to connecting

More information

Completing the picture

Completing the picture HIGH VoltaGe cable accessories for 72 kv up to 170 kv Completing the picture based on experience is the future nkt cables GmbH nkt was established in 1891 as cable manufacturer. in 1999 nkt a/s denmark

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

600/1000V, XLPE Insulated Cables according to IEC

600/1000V, XLPE Insulated Cables according to IEC 600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,417 35 41.0 2,865 50 44.0 3,391 70 48.0 4,272 95 51.5 5,266 120 55.5 6,232

More information

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable 0.6/1kV Al-Cu XLPE Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS 1.IEC;VDE ;ICEA;AS/NZS; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number of cores : One core, two cores, three cores, 3+1 cores,

More information

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv POLYCAB WIRES PVT LTD TECHNICAL DETAILS HT XLPE S UPTO 45Kv C O N T E N T S INTRODUCTION ADVANTAGE OF POLYCAB XLPE S SELECTION OF S TECHNICAL DATA Conductor Resistance Current Rating Cable Short Circuit

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS MEDIUM VOLTAGE MV TERMINATIONS INDOOR SINGLE CORE TERMINATION - ELTI-1C APPLICATION Utilisation indoor. in boxes and compact switchgears. in terminal boxes located outdoor and subject to condensation.

More information

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey) LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

EXTRA HIGH VOLTAGE c a b l e s

EXTRA HIGH VOLTAGE c a b l e s EXTRA HIGH VOLTAGE c a b l e s MANUFACTURES A RANGE OF HIGH VOLTAGE AND EXTRA HIGH VOLTAGE CABLES AT ITS FACILITY AT VADODARA The newly commissioned state-of-the-art facility at Vadodara has the capacity

More information

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH c A B L E 5 [B) Techno Flex manufacture high quality heavy duty power cable confirming to IS: 1554 (Part -1) L.T. 1100 volts grade CONSTRUCTION DETAILS:- Power Cable CONDUCTOR Plain bright annealed copper!

More information

First South East European Regional CIGRÉ Conference, Portoroz KV 2 X 1000MW SUBMARINE CABLE CROSSING OF THE DARDANELLES STRAIT IN TURKEY

First South East European Regional CIGRÉ Conference, Portoroz KV 2 X 1000MW SUBMARINE CABLE CROSSING OF THE DARDANELLES STRAIT IN TURKEY First South East European Regional CIGRÉ Conference, Portoroz 2016 SEERC 2-03 400KV 2 X 1000MW SUBMARINE CABLE CROSSING OF THE DARDANELLES STRAIT IN TURKEY GÜLNAZİ YÜCE Turkish Electricity Transmission

More information

UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG

UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG SOUTHWIRE SOLUTIONS FOR UNDERGROUND TRANSMISSION CABLES SERVICES XLPE Cables 69 through 400 kv with Copper and Aluminum conductors through 6,800 kcmil

More information

New TITANEX PREMIUM. No limit!

New TITANEX PREMIUM. No limit! New TITANEX PREMIUM No limit! A single flexible cable... TITANEX PREMIUM meets your specific needs in many areas and industries: entertainment, motion picture and broadcasting; power supply of submerged

More information

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of Introduction GEMSCAB has been associated with marketing and manufacturing Electric s for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

PRODUCT CATALOGUE Volume 4

PRODUCT CATALOGUE Volume 4 PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road

More information

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively

More information