TEKNISK RIKTLINJE TR05-10E
|
|
- Miranda Chambers
- 6 years ago
- Views:
Transcription
1
2 Notes Change notes Date 1 (A) Revision of standards and new template 09 / Template changed.clause support clamp inserted. Clause creepage text revised. Clause Dry inserted in headline. Clause Dry inserted in headline. Clause locking of bolt and nut inserted. Clause installation conditions inserted. Clause placement of transposition installation sets revised. 10.8,2.5 revised added. 3 New template and change of clause numbers. Rev. clause 5.4.2, 6.1, 8.2.5, 9.2 installation requirements. Clause 9 inserted: nuts in long direction be installed on the side towards lower tower number. Inserted in clause 9.3 in vertical direction shall bolt head be installed on the upper side and nuts underneath. Inserted: Transposition sets shall not be installed at crossings with roads. 02 / 04 / / 06 / /28
3 Content 1 References Scope Definition Description Suspension insulator sets Straight line insulator set Angle insulator set V-string insulator set Tension insulator set Transposition insulator set Requirements Material Insulators Insulator fittings Power arc protection devices Suspension clamps Tension clamps Design General Attachment to crossarms Counterweights Power arc protection devices Mechanical requirements Electrical requirements General Creepage distance Power frequency withstand voltage Corona Radio interference /28
4 5.4.6 Lightning overvoltage Switching overvoltage Fault current Type test General Dimensions Mechanical strength Power frequency withstand voltage Corona Radio interference Lightning impulse withstand voltage Fault current Sample test General Dimensions Mechanical strength Delivery General Documentation Assembly drawing List of material Quality system Installation instructions Reports Transport and storing Installation General Installation of straight line, angle line and V-string insulator sets Straight line suspension insulator sets Angle line suspension insulator sets /28
5 9.2.3 V-string insulator sets Installation of tension and transposition insulator sets Tension insulator sets Transposition insulator sets Tables...22 Table 1 Withstand voltage Figures...23 Figure 1 Straight line suspension insulator set...23 Figure 2 Angle suspension insulator set /28
6 1 References Note that standards, regulations etc. which are referred to in these guidelines are subject to continuous change and can be withdrawn, revised or replaced. The contractor shall immediately inform the client of such changes. C.I.S.P.R Publication 16-SER C.I.S.P.R specification for radio disturbance and im munity measuring apparatus and methods C.I.S.P.R Publication 18 2 EN EN EN ISO 9001 IEC IEC IEC IEC ISO 5455 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits Insulators for overhead lines with a nominal voltage above 1 kv - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria Insulators for overhead lines with a nominal voltage above 1 kv - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria Quality management systems Requirements Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems. Overhead lines - Requirements and tests for fittings Insulators for overhead lines with a nominal voltage above V- A.C. Power Arc Tests on insulator sets Technical drawings Scales 6/28
7 SS SS-EN SvK TR 05-04E SvK TR 05-05E SvK TR 05-06E SvK TR 05-11E SvK TR 05-12E SvK TR 08 Radio interference from high voltage alternating current overhead power lines Overhead electrical lines exceeding 45 kv AC Technical Guidelines Conductors Technical Guidelines Suspension and support clamps Technical Guidelines - Tension clamps Technical Guidelines - Insulators Technical Guidelines - Insulator set fittings Tekniska riktlinjer Dokumentation 2 Scope These guidelines are applicable to suspension, tension and transposition insulator sets which are to be used on overhead lines with alternating current and comprise design, testing and installation. The intention of the specification is to guarantee satisfactory performance of insulator sets during the lifetime of the overhead line. 3 Definition Technical terms and definitions used in these guidelines: Insulator set Device for insulating conductors either in suspension or tension. Insulator string The insulating part of the insulator set consisting of one or more insulators joined together. Highest voltage for equipment The highest value of phase-to-phase voltage for which the equipment is designed. The highest voltage for equipment is designated Um in this document. 7/28
8 Corona extinction voltage The voltage where no corona is visible when the voltage is reduced from a level with visible corona. Fault current The greatest short duration current which is caused by either a short-circuit (I k ) or an earth fault (3I o ). 4 Description 4.1 Suspension insulator sets Straight line insulator set Insulator set for straight line and angle positions, with an angle of deviation <3 o (3,3 gon), for the suspension of single, twin or triple conductors in accordance with SvK TR 05-04, consisting of: one upper section connected to earth for the attachment to the supports one insulator string with power arc protection devices one lower live section with a suspension clamp or clamps The distance between sub-conductors shall be 450 mm up to and including a conductor diameter of 32 mm and 600 mm for conductor diameter greater than 32 mm. Twin conductors shall be arranged horizontally and triple conductors as an equilateral triangle with the apex downwards. See Figure Angle insulator set Insulator set for angles of deviation 3 o (3,3 gon), for the suspension of single, twin or triple conductors in accordance with SvK TR 05-04, consisting of: one upper section connected to earth for the attachment to supports or swing brackets one or two insulator strings with power arc protection devices one lower live section with a suspension clamp or clamps 8/28
9 The distance between sub-conductors shall be 450 mm up to and including a conductor diameter of 32 mm and 600 mm for conductor diameter greater than 32 mm. Twin conductors shall be arranged horizontally and triple conductors as an equilateral triangle with the apex downwards. See Figure V-string insulator set Insulator set for straight line and angle positions, with an angle of deviation <3 o (3,3 gon), for the suspension of single, twin or triple conductors in accordance with SvK TR 05-04, consisting of: two upper sections connected to earth for the attachment to supports or swing brackets two insulator strings arranged in a V-shape with power arc protection devices one lower live section with a suspension clamp or clamps The distance between sub-conductors shall be 450 mm up to and including a conductor diameter of 32 mm and 600 mm for conductor diameter greater than 32 mm. Twin conductors shall be arranged horizontally and triple conductors as an equilateral triangle with the apex downwards. See Figure Tension insulator set Insulator set for the termination of single, twin or triple conductors in accordance with SvK TR 05-04, consisting of: one inner section connected to earth for the attachment to supports one or two insulator strings with power arc protection devices one outer live section with a tension clamp or clamps The distance between sub-conductors shall be 450 mm up to and including a conductor diameter of 32 mm and 600 mm for conductor diameter greater than 32 mm. Twin conductors shall be arranged horizontally and triple conductors as an equilateral triangle with the apex downwards. See Figure Transposition insulator set Insulator set for rotating phases in lines with single, twin or triple conductors in accordance with SvK TR 05-04, consisting of: one inner live section with a tension clamp or clamps one or two insulator strings with power arc protection devices one outer live section with a tension clamp or clamps 9/28
10 The distance between sub-conductors shall be 450 mm up to and including a conductor diameter of 32 mm and 600 mm for conductor diameter greater than 32 mm. Twin conductors shall be arranged horizontally and triple conductors as an equilateral triangle with the apex downwards. See Figure 5. 5 Requirements 5.1 Material Insulators Insulators shall conform to the requirements of SvK TR Insulator fittings Insulator fittings shall conform to the requirements of SvK TR Power arc protection devices Power arc protection devices shall conform to the requirements of SvK TR Suspension clamps Suspension clamps shall conform to the requirements of SvK TR Tension clamps Tension clamps shall conform to the requirements of SvK TR Design General The insulator sets shall comprise as few individual components as practical to minimise the number of current transition locations. In addition the overall length of the insulator set shall be designed to be as short as possible Attachment to crossarms The attachment of suspension insulator sets to crossarms shall be designed such that the pivot point of the insulator swing is as close as possible to the lower edge of the crossarm and allows swing transverse to the direction of the line. The attachment of V-string insulator sets to crossarms shall be designed such that the upper pivot point of the insulator swing is as close as possible to the lower edge of the crossarm and allows swing longitudinally in the direction of the line. 10/28
11 The attachment of tension insulator sets to crossarms shall be designed such that the innermost pivot point of the insulator set is as close as possible to the crossarm and allows swing transverse to the direction of the line Counterweights Straight line and angle suspension insulator sets for the suspension of single, twin or triple conductors shall be so designed as to allow for the addition of counterweights when necessary. The transverse swing of suspension insulator sets, with counterweights fitted to suspension clamps, shall be limited to 45. See SvK TR The attachment of counterweights for insulator swing exceeding 45 shall be subject to the approval by the client Power arc protection devices Power arc protection devices shall conform to the requirements of SvK TR Radiated heat from power arcs shall not damage insulator sets. 5.3 Mechanical requirements Insulator sets shall conform to the mechanical requirements of Swedish Standard SS- EN When designing / dimensioning insulator fittings by means of stress calculations the following additional requirements shall be fulfilled. The combined stress (σ comb) of tension, bending and shear shall be less than the characteristic strength fuk at a load equivalent to Fk in accordance with Swedish Standard SS-EN clause 11.6.SE.1.1. The combined stress (σ comb) of tension, bending and shear shall be less than the characteristic strength fyk at a load equivalent to 1,1 times the load Rd in accordance with Swedish Standard SS-EN clause 11.6.SE.1.1. The combined stress of tension, bending and shear shall be calculated according to the formula: comb x 2 y x y When testing fittings made from steel or aluminium permanent deformation due to tension, bending and shear stress may not occur at a load less than Fdef where; Fdef= Rd 1,1 11/28
12 Rd is the dimensioning load in the serviceability limit state in accordance with Swedish Standard SS-EN clause 11.6.SE.1.1. The breaking load (Fu) achieved during testing shall, for fittings made from steel and aluminium which have been statistically tested in accordance with EN , exceed Fk. The breaking load (Fu1) achieved during testing shall for other fittings exceed 110% of Fuk where : Fu1= Fk 1,1 Definitions Rd = Dimensioning load in the serviceability limit state Fdef = Minimum required test deformation load Fk = Dimensioning load in the ultimate limit state Fu = Achieved test breaking load Fu1= Achieved test breaking load fuk = The characteristic ultimate tensile strength given in regulations for the material concerned. fyk = The characteristic yield stress given in regulations for the material concerned. 5.4 Electrical requirements General Electrical designing/dimensioning shall, in addition to what is stated in these technical guidelines, be performed in accordance with Swedish Standard SS-EN The length of the insulator string for insulator sets intended for insulation between phase and earth shall be such that the required arcing distance to achieve the withstand voltages given in Table 1 are obtained. The length of the insulator string in insulator sets intended for insulation between phases shall be such that minimum arcing distances of 130% and 137% of that for phase to earth insulation are obtained for the highest voltages for equipment of 245 kv and 420 kv respectively. 12/28
13 5.4.2 Creepage distance The creepage distance, in accordance with IEC and 2, of an insulator divided by the maximum operating voltage across the insulator in the insulator set shall be at least: 22 mm/kv in areas where very light, or none, pollution can be expected. 28 mm/kv in areas where light pollution can be expected. 35 mm/kv in areas where medium pollution can be expected. 44 mm/kv in areas where heavy pollution can be expected. 55 mm/kv in areas where very heavy pollution can be expected Power frequency withstand voltage The power frequency withstand voltage of insulator sets, which are intended for phase to earth insulation, shall be the minimum voltage stated in Table 1 when tested in accordance with EN The power frequency withstand voltage of insulator sets, which are intended for phase to phase insulation, shall be a minimum of times the voltage stated in Table 1 when tested in accordance with EN Corona The insulator set shall have no visible corona at the test voltage defined by: U m Test voltage *1,1 3 Where Um is the highest voltage for equipment stated in Table Radio interference The radio interference level for insulator sets shall be less than 60 db at the highest voltage for equipment with 50 Hz alternating voltage (r.m.s. value) over 1V interference voltage and 500 khz measuring frequency. The radio interference level shall conform to the requirements of Swedish Standard SS Lightning overvoltage The lightning impulse withstand voltage for insulator sets intended for phase to earth insulation shall be that stated in Table 1 when tested in accordance with EN Switching overvoltage The switching impulse withstand voltage for insulator sets intended for phase to earth insulation shall be that stated in Table 1 when tested in accordance with EN /28
14 The switching impulse withstand voltage for insulator sets intended for insulation between phases shall be a minimum of 140% for 245 kv and 150% for 420 kv highest voltages for equipment of that stated in Table 1 when tested in accordance with EN Fault current Insulator sets shall be thermally designed to resist the stated fault current and fault time so that the mechanical strength of fittings, which are subject to fault current, is not weakened due to the heating caused by the fault current. In addition the zinc layer of hot-dip galvanised steel fittings is not to be damaged. Welding due to power arcs between fittings included in insulator sets shall be as far as possible avoided. The attachment of the insulator sets to the supports shall be designed to resist the stated fault current and fault time so that welding does not occur between the contact surfaces. 6 Type test 6.1 General Unless otherwise agreed the type test is to be performed in accordance with clause 6.2, on one test insulator set for each type, included all components. Type test is to be performed in accordance with clauses on request of the client and shall be performed at an agreed quantity of insulator sets. The tests shall be performed in such a way that neither the method nor the equipment affects the result. Tension insulator sets shall be horizontal installed during tests in accordance with Figure Dimensions The intention of this test is to check that the insulator set fulfils the requirements in accordance with clause 5.2 and also is in accordance with the manufacturers drawing regarding measurements. 6.3 Mechanical strength The intention of this test is to verify the mechanical strength of a complete insulator set in accordance with clause /28
15 The insulator set, excluding insulators, arcing horn and clamp, is to be installed in a tensile testing machine and loaded to the stated failing load. Failure may not occur in any of the included fittings nor may yoke plates be deformed to such an extent that the purpose of the yoke cannot be fulfilled. 6.4 Power frequency withstand voltage The intention of this test is to establish the wet power frequency withstand voltage of a complete insulator set. Suspension insulator sets with suspension clamps and conductors are to be installed in accordance with Figure 1. V-string insulator sets with suspension clamps and conductors are to be installed in accordance with Figure 3. The insulator set is to be installed such that the clearance from live to earth given in Table 1 is obtained. The insulator set is then to be subjected to 50 Hz alternating current. This test is to be performed as a wet test in accordance with EN The wet power frequency withstand voltage of insulator sets, which are intended for phase to earth insulation, shall be the minimum voltage stated in Table 1. The wet power frequency withstand voltage of insulator sets, which are intended for phase to phase insulation, shall be a minimum of times the voltage stated in Table Corona The intention of this test is to establish the corona extinction voltage for a complete insulator set and is to be performed in a fully-darkened room. During the corona test the use of either field glasses with a minimum optical performance 7x50, or an image intensifier with light amplification greater than in accordance with IEC 61284, is recommended. Suspension insulator sets are to be installed in accordance with clause 6.4. The distance from the live phase to earth shall be as stated in Table 1 and the insulator set is to be subjected to 50 Hz alternating current. The corona extinction voltage shall exceed the calculated test voltage in accordance with clause The corona extinction voltage is to be recorded by colour photographs, one with visible corona and another at the corona extinction voltage level, with the voltage levels being indicated on the photographs. The test shall be performed in accordance with the applicable sections of IEC /28
16 6.6 Radio interference The intention of this test is to establish the level of radio interference for a complete insulator set. Insulator sets are to be installed in accordance with clause 6.4 with the distance from the live phase to earth being as stated in Table 1. The test shall be performed with the highest voltage for equipment, 50 Hz alternating voltage (r.m.s. value) over 1 V interference voltage and 500 khz measuring frequency. Testing is to be in accordance with C.I.S.P.R publication 16-SER and the results evaluated in accordance with C.I.S.P.R publication The level of interference at the highest voltage for equipment shall fulfil the requirements of clause Lightning impulse withstand voltage The intention of this test is to establish the switching impulse withstand voltage for a complete insulator set. Insulator sets are to be installed in accordance with clause 6.4, with the distance from the live phase to earth being as stated in Table 1. They are then to be subjected to a switching impulse withstand voltage test in accordance with EN The switching impulse withstand voltage shall exceed the voltage stated in Table Fault current The intention of this test is to establish the capacity of a complete insulator set to withstand flash-over with a power arc. The suspension insulator set with clamps and conductors is to be installed and tested in accordance with IEC test series X. The insulator set shall fulfil the acceptances criteria in accordance with IEC Sample test 7.1 General Sample tests are to be carried out by the manufacturer on an insulator set selected at random from the lot to be supplied. 16/28
17 7.2 Dimensions This test is to be performed in accordance with clause Mechanical strength This test is to be performed in accordance with clause 6.3 if agreed between the client and the manufacturer. 8 Delivery 8.1 General The client shall, according to these guidelines, approve insulator sets before delivery. For approval the manufacturer shall show that the insulator set conforms to the guidelines. The manufacturer shall provide documentation in accordance with clauses to inclusive for approval. The approval of drawings by the client does not release the manufacturer from his obligations regarding the insulator set complying with these guidelines. All documentation shall be written in Swedish or English. 8.2 Documentation A summary of documentation requirements is presented in SvK TR Assembly drawing The assembly drawing shall have a minimum of two views at an appropriate scale in accordance with ISO On the drawing shall be given: Type and/or catalogue number Principal dimensions Arcing distance Creepage distance Failing load Fault current Weight 17/28
18 List of materials List of material Description of material in included parts Quality system Quality system in accordance with EN ISO Installation instructions Installation instructions with required drawings Reports Reports in accordance with clause 6 Type test shall be provided for the clauses that are performed in accordance with clause 6. Reports in accordance with clause 7 Sample test Transport and storing The insulator sets shall be packed up in that way that they will not be damaged or fouled at transport, construction and storing. 9 Installation 9.1 General Installation of insulator sets shall be performed in accordance with the relevant drawings. Bolts and nuts shall be locked with two punches or other mechanical metallic locking system that is accepted by the client. 9.2 Installation of straight line, angle line and V-string insulator sets Suspension sets shall be installed vertical to the direction of the line. Maximum allowed deviation to the vertical plane at the suspension clamp is L/40, where L= length of the insulator set Straight line suspension insulator sets. Power arc protection devices on suspension insulator sets shall be installed in such a way that any power arc will have a predestined direction transverse to the direction of the line and outwards away from the insulator set and the support. With a horizontal phase arrangement power arc protection devices for the middle phase shall be installed in such a way that the power arc will have a predestined direc- 18/28
19 tion to the right transverse to the direction of the line when looking towards higher support numbers. The pivot bolt nut and the eye of the split pin in a socket are to be installed facing the support. For the middle phase the nut and the eye of the split pin are to be installed facing left when looking towards higher support numbers. See Figure 6a. The pivot bolt nuts in fittings between the conductors and the yoke plate are to be installed facing each other in twin bundle conductor arrangements and similarly for the upper two conductors in triple bundle conductor arrangements. See Figures 6b and 6c respectively. In longitudinal direction shall the nuts be installed facing against lower support number Angle line suspension insulator sets Power arc protection devices on angle suspension insulator sets shall be installed in such a way that any power arc will have a predestined direction upwards. In inclined suspension insulator sets the pivot bolt nut and the eyes of split pins in sockets are to be installed facing downwards. Nuts on horizontally orientated pivot bolts and the eyes of split pins in sockets are to be installed facing the support. For the middle phase the nut and the eye of the split pin are to be installed facing left when looking towards higher support numbers. The pivot bolt nuts in fittings between the conductors and the yoke plate are to be installed facing each other in twin bundle conductor arrangements and similarly for the two upper conductors in triple bundle conductor arrangements. In longitudinal direction shall the nuts be installed facing against lower support number V-string insulator sets Power arc protection devices on V-string suspension insulator sets shall be installed in such a way that any power arc will have a predestined direction upwards. For inclined insulator sets the pivot bolts nuts, the eyes of split pins in sockets and power arc protection device attachment arms, are to be installed facing downwards. Nuts in horizontally orientated pivot bolts and the eyes of split pins in sockets are to be installed facing the support. For the middle phase the nut and eyes of the split pins are to be installed facing left when looking towards higher support numbers. 19/28
20 The pivot bolt nuts in fittings between the conductors and the yoke plate are to be installed facing each other in twin bundle conductor arrangements and similarly for the two upper conductors in triple bundle conductor arrangements. In longitudinal direction shall the nuts be installed facing against lower support number. 9.3 Installation of tension and transposition insulator sets Tension insulator sets Power arc protection devices on tension insulator sets shall be installed in such a way that any power arc will have a predestined direction upwards. Nuts on vertical orientated pivot bolts, the eyes of split pins in sockets and power arc protection device attachment arms, are to be installed facing downwards. Nuts on horizontally orientated pivot bolts and the eyes of split pins in sockets are to be installed facing the support. For the middle phase the nuts and eyes of the split pins are to be installed facing left when looking towards higher support numbers. See Figure 7a. The pivot bolt nuts on fittings between the conductors and the yoke plate are to be installed facing each other in twin bundle conductor arrangements and similarly for the upper conductors in triple bundle conductor arrangements. See Figures 7b and 7c respectively. For bolts in vertical direction shall the bolt head be on the upper side and the nut underneath Transposition insulator sets Transposition tension sets are not allowed in spans that cross traffic routes, railways and transmission lines nor in the adjacent spans. Power arc protection devices on transposition insulator sets shall be installed in such a way that any power arc will have a predestined direction upwards. Nuts on vertically orientated pivot bolts, the eyes of pins in sockets and power arc protection device attachment arms, are to be installed facing downwards. Nuts on horizontally orientated pivot bolts and the eyes of split pins in sockets are to be installed facing the support. For the middle phase the nuts and the eyes of split pins are to be installed facing left when looking towards higher support numbers. See Figure 7a. 20/28
21 The pivot bolts nuts on fittings between the conductors and the yoke plate are to be installed facing each other in twin bundle conductor arrangements and similarly for the two upper conductors in triple bundle conductor arrangements. See Figures 7b and 7c respectively. For bolts in vertical direction shall the bolt head be on the upper side and the nut underneath. 21/28
22 10 Tables Table 1 Withstand voltage Highest voltage Rated withstand voltages Distance for equipment Um Lightning impulse Switching impulse Power frequency phase to earth 1) phase-phase kv kv kv kv m ) Distances to be used for corona tests 22/28
23 11 Figures Figure 1 Straight line suspension insulator set Figure 2 Angle suspension insulator set Figure 2a Single string 23/28
24 Figure 2b Double string Figure 3 V-string suspension insulator set 24/28
25 Figure 4 Tension insulator set Figure 4a Single string Figure 4b Double string 25/28
26 Figure 5 Transposition tension insulator set Figure 5a Single string Figure 5b Double string 26/28
27 Figure 6 Straight line suspension insulator set bolt orientation The arrows indicate the direction bolts must face when looking towards higher support numbers. Figure 6a Straight line support Figure 6b Twin bundle conductor Figure 6c Triple bundle conductor 27/28
28 Figure 7 Tension insulator set bolt orientation The arrows indicate the direction bolts must face. Towards higher support numbers Figure 7a Terminal support Figure 7b Twin bundle conductors Figure 7b Triple bundle conductors 28/28
Overhead transmission lines Spacers
= SVENSKA KRAFTNÄT SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AEL, Asset Management Lines OUR REFERENCE TR05-08E DATE 2016-06-09 CONSU12TATIONS TECHNICAL GUIDELINE REVISION 3 APPROVED Overhead transmission
More informationOverhead transmission lines Tension clamp
SVENSKA KRAFTNÄT T~ SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AFL, Asset Management Lines OUR REFERENCE TR05-06E DATE 2016-06-09 CONSULTÅTIONS m /j(j TECHNICAL GUIDELINE REVISION 3 Td APPROVED Overhead
More informationOverhead transmission lines Vibrationdampers
SVENSKA KRAFTNÄT SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AFL, Asset Management Lines OUR REFERENCE TR05-09-1E DATE 2016-06-09 CONSULTATIONS TECHNICAL GUIDELINE REVISION 3 Td APPROVED Overhead transmission
More informationSUSPENSION 04 CLAMPS
SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61325 First edition 1995-03 Insulators for overhead lines with a nominal voltage above 1 000 V Ceramic or glass insulator units for d.c. systems Definitions, test methods and
More informationTransformer bushings, type GOH. Technical guide
Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60383-2 First edition 1993-04 Insulators for overhead lines with a nominal voltage above 1 000 V Part 2: Insulator strings and insulator sets for a.c. systems Definitions, test
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA
023 : 2006 CEB STANDARD 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA Specification for 12kV & 36kV LOAD BREAK SWITCHES CEB Standard 023 : 2006 CEYLON ELECTRICITY BOARD No. 50, Sir
More informationREFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS
TITLE SPECIFICATION FOR POLE- MOUNTED DATE: JUNE 2006 PAGE: 1 OF 17 TABLE OF CONTENTS Page FOREWORD...2 INTRODUCTION...3 1 SCOPE...3 2 NORMATIVE S...3 3 DEFINITIONS AND ABBIATIONS...3 4 REQUIREMENTS...3
More informationVEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY
VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Ltd. VEIKI-VNL Electric Large Laboratories Ltd. is an independent accredited testing member laboratory of
More informationGlass insulators for kv overhead lines and substations. Global Insulator Group
Global Insulator Group 6-210 Katusepapi, Tallinn, 11412, Estonia tel +372-622-8118, fax +372-622-8119, cell +372 522-3551 e-mail: ved@gig-group.com, puchkov@gig-group.com www.gig-group.com Glass insulators
More information1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide
1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationResin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide
1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationSECTION 11 INTERMODAL EQUIPMENT
SECTION 11 INTERMODAL EQUIPMENT ROA MANUAL SCHEDULE OF AMENDMENTS SECTION 11 AMENDMENT NUMBER PAGES AMENDED AMENDMENT SUMMARY DATE ISSUED TABLE OF CONTENTS Section Description Page No. 11.1 SCOPE... 11-1
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements
More informationVolume-III : Section-I 370 Technical Specifications
Volume-III : Section-I 370 TECHNICAL SPECIFICATION-PIERCING INSULATOR 5.1 Insulation Piercing Connectors (IPC) 5.1.1 Insulation Piercing Connectors (IPC) are used for making Tee/Tap-off/Service connectors
More informationPresented to the IAPMO Standards Review Committee on December 9, 2013
Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented
More informationEconomic and Social Council
United Nations Economic and Social Council ECE/TRANS/WP.29/2016/83 Distr.: General 31 August 2016 Original: English Economic Commission for Europe Inland Transport Committee World Forum for Harmonization
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17453-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.07.2017 to 02.07.2022 Holder of certificate: SPIE
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationBushings for High Voltage AC Applications
Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure
More informationPROVINCIAL ELECTRICITY AUTHORITY
INSULATORS Specification No.: RINS-002/2553 Approved date: 02/02/2553 Rev. No.: 1 Form No. 01-1 Page 1 of 7 Invitation to Bid No. : C C1 1a 1b Material, equipment, and specifications for INSULATORS General
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More information43-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR MV SHUNT POWER CAPACITOR BANK UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Description Page 1.0 SCOPE 3
More informationCombined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications
4-O 1/15 Combined Current and Voltage Instrument Transformer CVS-P-4-O Technical Specifications Rev. Date Revision Description Prepared by Checked by Approved by 0 3/10/15 First Issue E. Scala L. Peretto
More informationMATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...
153 Contents General.................................................................................................. 154 C-bracket.................................................................................................
More informationTechnical Specification
Section - 7 Technical Specification OF 33KV OUTDOOR DROP OUT FUSE CUT-OUT AND FUSE LINK AND 33KV OUTDOOR TYPE SINGLE PHASE METAL OXIDE (ZNO) GAPLESS LIGHTNING ARRESTER 84 7.1. TECHNICAL SPECIFICATION OF
More informationWESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2
Sl. No. WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO GUARANTEED TECHNICAL PARTICULARS 1 of 2 REQUIREMENTS 11 Kv, 200 Amps, A.B Switches. Particulars 1 Maker's name and Country of origin. 2 Type
More informationANSI Design Test Report ANSI Glass Bells Catalog # PSN21156
ANSI Design Test Report ANSI 52-11 Glass Bells Catalog # PSN21156 This design test report records the results of laboratory tests performed on the ANSI 52-11 Glass Bells which met or exceeded all performed
More informationCENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B
CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B TCV2 Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com
More informationINTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.
INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side
More information026-2 : 1996 CEB STANDARD
026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable
More informationSPACERS AND SPACER DAMPERS
SPACERS AND SPACER DAMPERS 0 131 Contents General... 132 Spacer damper aluminium, for horizontal twin bundles... 138 Spacer damper aluminium, for vertical twin bundles... 138 Spacer damper aluminium, for
More information045 : 2000 CEB STANDARD
045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.
More informationThis standard covers the requirements of lighting chains. This standard covers only the safety requirements.
FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the
More informationDNVGL-CG-0194 Edition July 2017
CLASS GUIDELINE DNVGL-CG-0194 Edition July 2017 The content of this service document is the subject of intellectual property rights reserved by ("DNV GL"). The user accepts that it is prohibited by anyone
More informationPower Arc Testing on Insulator Sets
Power Arc Testing on Insulator Sets Abstract:Insulator sets are among the most common components in transmission networks and their quality and performance play a vital role in ensuring a reliable electricity
More informationDisconnectors and earthing switches up to 25 kv AC
Disconnectors and earthing switches up to 25 kv AC Sicat 8WL6144 for overhead contact line systems in main-line railways siemens.com/rail-electrification The disconnectors and earthing switches of the
More information34-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES
More informationTEST METHODS CONCERNING TRANSPORT EQUIPMENT
PART IV TEST METHODS CONCERNING TRANSPORT EQUIPMENT - 403 - CONTENTS OF PART IV Section Page 40. INTRODUCTION TO PART IV... 407 40.1 PURPOSE... 407 40.2 SCOPE... 407 41. DYNAMIC LONGITUDINAL IMPACT TEST
More informationTransformer bushings, type GOA 250. Installation and maintenance guide
Transformer bushings, type GOA 250 Installation and maintenance guide This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor
More informationTECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT
Page 1 (7) TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT Title Document Asynchronous electric motors TBE 103 Issue 6 (E) Contents 1 GENERAL... 2 2 DEFINITIONS... 2 3 GENERAL PRODUCT REQUIREMENTS... 3
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationHigh Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK
High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK Definitions Transmission Line Arresters Backflashover Occurs when lightning strikes the tower structure or overhead
More informationSECTION 8 RAIL FREIGHT VEHICLE UNDERFRAME AND BODY STRUCTURES
SECTION 8 RAIL FREIGHT VEHICLE UNDERFRAME AND BODY STRUCTURES ROA MANUAL SCHEDULE OF AMENDMENTS SECTION 8 AMENDMENT NUMBER PAGES AMENDED AMENDMENT SUMMARY DATE ISSUED Portions of this Section of the ROA
More informationTABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3
TITLE SPECIFICATION FOR MEDIUM VOLTAGE DATE: FEBRUARY 2015 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 NORMATIVE S... 3 3 DEFINITIONS AND ABBIATIONS... 3 4 REQUIREMENTS...
More informationOutdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications
Outdoor live tank SF 6 circuit breaker Type OHB for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers
More informationOIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC
OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench
More informationproduces and delivers products worldwide can provide the optimal solution for your requirements. are dedicated to supplying you with
www.ppcinsulators.com The very Best. The very Best. That s what we deliver. Only a company that develops, produces and delivers products worldwide can provide the optimal solution for your requirements.
More informationTECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE
TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE The hardware fittings suitable for tension string to be used for 11KV consisting of following
More informationMEDIUM VOLTAGE NETWORKS
MEDIUM VOLTAGE NETWORKS LIGHTNING ARRESTERS & INSULATORS SICAME GROUP OUR EXPERIENCE With 25 years of experience in the field of over protection for medium lines, DERVASIL designs and manufactures zinc
More informationResin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK
1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationE/ECE/324/Rev.1/Add.57/Rev.3 E/ECE/TRANS/505/Rev.1/Add.57/Rev.3
30 November 2017 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and
More informationAustin Insulators Inc. Manufacturers of Austin Base & Guy Insulators and Isolation Transformers for Radio Antenna Towers.
Austin Insulators Inc. Manufacturers of Austin Base & Guy Insulators and Isolation Transformers for Radio Antenna Towers Product Catalogue e&oe 05.11.01.a Austin Insulators Inc. Austin Ring Type Isolation
More informationSilicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)
Silicone Suspension/Tension Insulator 120kN up to LIWV 450kV (BIL) CABLE SYSTEMS FOR ENERGY & ROLLING STOCK APPLICATIONS MV Silicone Tension Insulators The high tensile strength of glass fibre has been
More informationTechnical Specification for 33 KV 200 AMPs,H.G,Fuse set.
Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. 1. SCOPE:- This specification covers the manufacture, testing and supply of 33KV 200 Amps, H.G. Fuse sets 2. The 33 KV H.G. Fuses shall be suitable
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationGLASS INSULATORS FOR OVERHEAD POWER TRANSMISSION LINES
GLASS INSULATORS FOR OVERHEAD POWER TRANSMISSION LINES 2010 GLASS INSULATORS Depending on their purpose and construction, the insulators are classified as follows: line (suspension, pin, cap-and-pin);
More informationROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL
ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL TopStick Fixed installation technology LOW VOLTAGE SWITCH PANEL TopDraw plus The modular system solution Quality, Conformity Increased
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60092-503 Second edition 2007-06 Electrical installations in ships Part 503: Special features AC supply systems with voltages in the range of above 1 kv up to and including 15
More informationVolume 1 Series 2200 Specification for Road Works. Clause Title Page
PARAPETS Contents Clause Title Page 2201 General... 2 2202 Vehicle... 2 2203 Anchorages and Attachment Systems for Vehicle... 2 2204 Amendments and Additions to BS 6779... 3 2205 Protection Against Corrosion...
More informationEquipotential Bonding of Rail Vehicles to Running Rail Potential
Railway Group Standard Equipotential Bonding of Rail Vehicles to Running Rail Potential Synopsis This standard mandates the requirements for equipotenial bonding of rail vehicles to comply with the Electricity
More informationEARTH WIRE FITTINGS 08
EARTH WIRE FITTINGS 08 8 EARTH WIRE FITTINGS 119 Contents General... 120 C-bracket... 123 Suspension clamp with bolt, with straps, for steel and copper conductors... 123 Suspension clamp with bolt, with
More informationSFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *
SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * PRODUCT: Heavy Duty Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards
More informationPOLYMER INSULATOR. Index
POLYMER INSULATOR Index INTRODUCTION...2 IEC COMPOSITE INSULATORS...7 ANSI COMPOSITE INSULATORS...14 Introduction General This new generation of Polymer Insulator characterized with: Small Light High mechanical
More informationCircuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.
Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical
More informationproduces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.
www.ppcinsulators.com The very Best. The very Best. That s what we deliver. Long Rod Insulators Only a company that develops, produces and delivers products worldwide can provide the optimal solution for
More informationشركة كهرباء محافظة القدس المساهمة المحدودة
Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories
More informationMenu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents
Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60898.1:2004 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar
More informationType SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear
Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated
More informationGuideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society
Guideline No.: E-04(201510) E-04 GENERATORS Issued date: October 20,2015 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection
More informationCompatibility Between Electric Trains and Electrification Systems
Compatibility Between Electric Trains and Electrification Systems Synopsis Process for managing change that affects the compatibility between electric trains and electrification systems Submitted by Signatures
More informationPRE-RELEASE VERSION (FDIS)
IEC 61238-1-1 Edition 1.0 2018-02 PRE-RELEASE VERSION (FDIS) Compression and mechanical connectors for power cables Part 1-1: Test methods and requirements for compression and mechanical connectors for
More informationVariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)
CP9817 PAGE: 1 of 16 CERTIFIED TEST REPORT VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC 60099-4 (99-4) 0711 Supersedes 0601 Cooper Industries. All Rights Reserved. CP9817 PAGE:
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationTransformer bushings, type GSA-OA Technical guide
Transformer bushings, type GSA-OA Technical guide ZSE 2750- en, Rev. 5, 2005-05-5 This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to
More informationTABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...
TITLE SPECIFICATION FOR PORTABLE DATE: JULY 2006 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD...3 INTRODUCTION...4 1 SCOPE...4 2 NORMATIVE S...4 3 DEFINITIONS AND ABBIATIONS...4 4 REQUIREMENTS...5 4.1
More informationRSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2
3 ELECTRIC TRACTION SYSTEMS 2 3.1. SAFE FOR PEOPLE 2 3.1.1. Electric Traction System 2 3.1.2. Protection against unwanted access 2 3.1.3. Fencing 2 3.1.4. On bridges and other structures 2 3.1.5. At level
More information1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide
1ZSE 2750-111 en, Rev. 9 Transformer bushings, type GSA-OA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationMEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear
MEDIUM VOLTAGE PRODUCTS Powerbloc Pre-assembled modules for building medium voltage switchgear Powerbloc are the ideal solution for replacing fixed circuit breakers with withdrawable circuit breakers,
More information20 HUBER+SUHNER RADOX SOLAR
All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationE/ECE/324/Rev.1/Add.57/Rev.2/Amend.4 E/ECE/TRANS/505/Rev.1/Add.57/Rev.2/Amend.4
11 July 2016 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions for
More informationNeutral section. Features. Sicat 8WL5545-4D/4F for overhead contact line systems. siemens.com/rail-electrification
Neutral section Sicat 8WL5545-4D/4F for overhead contact line systems siemens.com/rail-electrification When installed in pairs, the type Sicat 8WL5545-4D/4F neutral sections serve as phase separation section
More informationOutdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications
Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers
More informationMechanical Trainstop Systems
Mechanical Trainstop Systems Synopsis This document defines the functional requirements for mechanical trainstop systems and the requirements relating to their use on both track and trains. Signatures
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3
More informationUnderfloor to desk 231
Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.
More informationEnglish translation authorized by DIBt Original version in German language
Date: Reference: 29/09/2014 I 36-1.14.4-101/13 English translation authorized by DIBt Original version in German language Approval number: Validity Z-14.4-2 from: 29 September 2014 Applicant: Lindapter
More information3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability
3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability Power Transmission and Distribution 1 A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters:
More informationINSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00
INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR469100 BR25AT REV00 I CONTENT: 1 SAFETY 1.1 Safety instructions 1 1.2 Specified applications 1 1.3 Safety notes on the equipment operation 1 2 BR 25
More informationInvestigation into UK socket-outlets incorporating USB charging points
Investigation into UK socket-outlets incorporating USB charging points Electrical Safety First investigated a number of commercially available UK socket-outlets incorporating USB ports, as a repeat of
More informationSPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE
SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE The hardware fittings suitable for tension string to be used for 11KV / 22 KV consisting of following components.
More informationH e a t s h r i n k P r o d u c t G u i d e
P o w e r P r o d u c t s H e a t s h r i n k P r o d u c t G u i d e Introduction HellermannTyton is a world leader in providing systems and solutions for heatshrink applications. HellermannTyton utilises
More informationTITLE: SPECIFICATION FOR BENCH VICE & BENCH GRINDER TABLE OF CONTENTS. 0.1 Circulation List. 0.2 Amendment Record
Page 1 of 10 TABLE OF CONTENTS 0.1 Circulation List 0.2 Amendment Record FOREWORD 1. SCOPE 2. REFERENCES 3. TERMS AND DEFINITIONS 4. REQUIREMENTS 5. TESTS AND INSPECTION 6. MARKING AND PACKING 7. DEMONSTRATION
More informationDirectly Molded Polymer Surge Arresters
Directly Molded Polymer Surge Arresters Ideal means to reduce environmental impact Up to 420kV, Comply with IEC60099-4, Line discharge class 2-4 l Long-life performance (Hydrophobic silicone rubber) l
More informationCODE 10 OECD STANDARD CODE FOR THE OFFICIAL TESTING OF FALLING OBJECT PROTECTIVE STRUCTURES ON AGRICULTURAL AND FORESTRY TRACTORS
CODE 10 OECD STANDARD CODE FOR THE OFFICIAL TESTING OF FALLING OBJECT PROTECTIVE STRUCTURES ON AGRICULTURAL AND FORESTRY TRACTORS 1 TABLE OF CONTENTS INTRODUCTION... 3 1. DEFINITIONS... 3 1.1 Agricultural
More information