OPTOFIT CATALOGUE. FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES.

Size: px
Start display at page:

Download "OPTOFIT CATALOGUE. FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES."

Transcription

1 OPTOFIT CATALOGUE FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES. EXCLUSIVE AUSTRALIAN DISTRIBUTORS

2 B8/8 Introduction Metalfree (ADSS cables) and metal-armored (OPGW, OPPW) aerial cables with integrated optical fibres (called optical fibre aerial cables) are used to transmit information. The information is transmitted by means of modulated light pulses in the interior of the thin optical fibres. These fibres have a total diameter of approx. 300 µm. The optical fibre aerial cables can be stressed upto <!--[if!supportemptyparas]-->a limited tensile force without any increase of the optical signal damping in the fibres. However, in the case of a radial force, the optical damping will increase by bounds. This increase can lead to a reduction of the information flow through the fibres. The fibres with an additional length are beded in one or several relatively rigid coaxial tubes to avoid inadmissible stress. In the case of metalfree optical cables the tubes are beded in a supporting structure of aramid fibres. The optical fibre cable is finally covered with an extruded PE-mantle. The core of the metall-armored aerial cable is covered with one or more layers of Aluminium wires, Aluminium alloy wires or Aluminium-clad steel wires. As the optical fibres have to be protected against inadmissible radial forces during and after the installation of optical fibre aerial cables the fittings at the tension-, suspension- and fixing points have to meet special requirements. For common conductors and ground wire we use fittings for tension and suspension points which provoke the necessary grippage force by effecting of a high radial force (for example wedge type tension clamp, suspension clamp). Due to the high pressure sensitivity of optical fibres beded in the aerial cable these types of fittings are not suitable for optical fibre aerial cables. The fittings of the RIBE-Optofit-program are designed regarding this high pressure sensitivity. The fittings are especially adapted to this purpose. The induced radial forces are spread over a larger contact surface (for example dead end) in such a way that the fibres are not inadmissibly stressed and the necessary grippage forces are achieved. It is impossible to determine standardized accessories for optical fibre aerial cables as the structure of the different cables is very manifold. Fittings for optical fibre aerial cables mainly consist of the following group of fittings: - Helically formed fittings for tension and suspension points - Earth connections - Tower down-lead accessories - Vibration dampers Helically formed fittings form the major part of accessories for optical fibre aerial cables. They are composed of helically formed rods which - according to the respective application - are separate or preassembled, straight or bended on delivery. Helically formed accessories can be used to tension, to suspend or to connect conductors, optical fibre aerial cables, glass fibre rods and solid rods such as guys. In addition, helically formed accessories are used for protection or repair of conductors or optical fibre aerial cables, for attachment to post insulators and for tensioning of street lighting. Helically formed accessories have been used very succesfully since The application of helically formed accessories is not at all limited to overhead lines. Helically formed accessories are also used to a large extent for the construction of antennae, radar stations etc. The principle of operation of helically formed accessories is based on the principle of the development of a low pressure over a large area. The inside diameter of the unloaded helical rods is slightly smaller than the outside diameter of the conductor, optical fibre aerial cable or solid rod. By wrapping the helical rods on a conductor or optical fibre aerial cable, a spring tension is created, producing the necessary frictional contact. This spring tension is elastic and ensures a constant grip. To ensure the full performance, helically formed accessories must exactly be adapted to the outside diameter of conductor, optical fibre aerial cable or solid rod. In general, helically formed accessories are made of a material similar to that of conductor, optical fibre aerial cable or solid rod. Usually this garanties a similar corrosion resitivity. Installation of helically formed accessories can be done without any tools. Installation faults are nearly impossible. Mounting instructions are available on demand. Helically formed accessories are largely protected by patents or registration of designs. If helically formed accessories are required for applications other than those included in this catalogue, a specific inquiry is requested. The RIBE numbers of helically formed accessories start with a combination of letters that is followed by six figures and possibly letters added at the end. for example: AG The respective letters or figures have the following meaning: 1) Starting letters The first capital letter and in some cases the first and the second letter designate the respective type. A - Dead ends B - Spacers D - Vibration dampers J - Insulator ties L - Line guards LT - Suspension grips M - Bird flight diverters (star) Stand: 19. Juni 2006 Pfad: RIBE-Optofit/General/ Introduction/ 1 / 103

3 R, UR, UT - Protection rods S - Armor rods T - Suspension rods V - Line splices Z - Bird flight diverters (spring) The last capital letter and in some cases also the before last designate the material. A - Aluminium alloy B - Bronze G - Steel, h.d.g. H - Stainless steel K - Copper alloy P - Plastic material S - Other material combinations V - Copper-clad steel W - Aluminium-clad steel 2) Six figures The six figures of the RIBE number shall be considered as two groups, three figures each. The first group gives by pointing off the last figure the largest possible cable diameter for which the accessory is suitable (measurement: mm). The second group indicates the overall length of accessory in cm. 3) Letters added to the RIBE number The letters added to the RIBE number refer to special applications or the nature of the accessory. The respective letters have the following meaning: H - Suitable for post insulator with neck L - Suitable for "Längsbund" type insulator M - Suitable for "Mittelbund" type insulator li - Left hand outer lay accessory s - Special design Stand: 19. Juni 2006 Pfad: RIBE-Optofit/General/ Introduction/ 2 / 103

4 B8/9 Suspension arrangement Suspension arrangement for OPGW (schematic representation) 1... OPGW 2... Tower 3... C-shaped support 4... Armour grip suspension 5... Vibration damper 6... Shunt (optional) Suspension arrangement for thin ADSS cable (schematic representation) 1... ADSS cable 2... Shackle 3... Armour grip suspension 4... Vibration damper Stand: 26. Juni 2006 Pfad: RIBE-Optofit/General/ Suspension arrangement/ 3 / 103

5 B8/10 Tension arrangement Tension arrangement with OPGW passing the tower (schematic representation) 1... OPGW 2... Tower 3... Tension support 4... Pair of straps 5... Twisted double eye 6... Thimble 7... Helical dead end 8... Protection rods 9... Vibration damper Parallel groove clamp Shunt Tension arrangement with ADSS cable passing the tower (schematic representation) 1... ADSS cable 2... Wooden pole 3... Hook 4... Helical dead end Tension arrangement with OPGW at the tower with joint box (schematic representation) Stand: 17. Mai 2006 Pfad: RIBE-Optofit/General/ Tension arrangement/ 4 / 103

6 1... OPGW 2... Tower 3... Tension support 4... Pair of straps 5... Twisted double eye 6... Thimble 7... Helical dead end 8... Protection rods 9... Vibration damper Parallel groove clamp Shunt Fixing clamp Filler bolt Tension arrangement with ADSS cable at the tower with joint box (schematic representation) 1... ADSS cable 2... Tower Stand: 17. Mai 2006 Pfad: RIBE-Optofit/General/ Tension arrangement/ 5 / 103

7 3... Hook 4... Thimble 5... Helical dead end Stand: 17. Mai 2006 Pfad: RIBE-Optofit/General/ Tension arrangement/ 6 / 103

8 B8/11 String accessories for tower attachment of self supporting optical fibre aerial cables Variant A of tower attachment Variant B of tower attachment Variant C of tower attachment Stand: 17. Mai 2006 Pfad: RIBE-Optofit/General/ String accessories for tower attachment of self supporting optical fibre aerial cables/ 7 / 103

9 1... Vertical tension hinge 2... Turnbuckle (eye - eye) 3... Turnbuckle (clevis - eye) 4... Straight clevis eye 5... Adjustable clevis eye 6... Twisted double eye 7... Twisted clevis eye 8... Straight clevis eye 9... Pair of straps Horizontal U-bolt Shackle Horizontal tension hinge Tower Tension support Protection rods Thimble Dead end Remark: Detail informations of string accessories contain the RIBE-catalogue "Insulator string hardware". Stand: 17. Mai 2006 Pfad: RIBE-Optofit/General/ String accessories for tower attachment of self supporting optical fibre aerial cables/ 8 / 103

10 B800/0 Introduction to armour grip suspensions Design and performance: The armour grip suspension is used for the movable suspension of conductors and optical fibre aerial cables on suspension towers. The armour grip suspension is composed of a certain number of helically formed rods, a concave Neoprene insert consisting of two halfs and a clamp body. The helical rods are placed on the Neoprene insert at the suspension point. This centre assembly is fixed by the clamp body which due to positive locking prevents axial displacement of the conductor. The armour grip suspension - like the application of suspension clamps along with armour rods - does not impede asymmetric vibration and thus avoids local alternating bending stress. This is no static compression force existing in standard suspension clamps with and without armour rods due to the keeper with bolts. This is the principle difference of the armour grip suspension compared to suspension equipments commonly used up to now. The reinforcement of the cross-section by armor rods improves the lifetime of the vibrating conductor/ optical fibre aerial cable. However, it is no damping device to cope with conductor vibrations. The electrical connection of the helical rods and the suspension equipment is resistant to short-circuit current, i.e. it is capable to conduct the short circuit current of a conductor/ optical fibre aerial cable without damage. Helical rods and clamp bodies are made of high-tensile, corrosion-resistant aluminium alloy, inserts of Neoprene, straps and threaded bolts of hot-dip galvanized steel. Installation: The Neoprene composed of two concave halves is placed on the conductor/ optical fibre aerial cable at the suspension point and attached by the helical rods which are wrapped on the conductor/ optical fibre aerial cable with insert. The clamp body of the suspension equipment is placed on either side of the centre assembly thus that is embraced by the clamp body. The clamp body is attached by application of a bolt. Apart from a tubular hexagon box spanner, no special tooling is required for assembly. The assembly has to be performed in accordance with RIBE-Mounting Instruction No. 10. Stand: 10. August 2006 Pfad: RIBE-Optofit/ Suspension fittings/ Introduction to armour grip suspensions/ 9 / 103

11 B801/1 Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment) 1... Clamp body with neoprene-insert 2... Helical rods 3... Fig Fig Bolt 1 RIBE-Order-No. Clamping range RIBE-No. Helical rods a b Bolt 1 Mass/ I th F N (1+2) Clamp+Neoprene- Ribe-No. L Ø No. of rods Size s pcs mm Insert (1) mm mm mm mm mm kg ka kn LTA /17 9,0-9,7 B KA s 8 1,8 LTA /5 9,8-10,4 (Fig. 1) KA s 9 1,8 LTA /6 10,5-11,1 KA s 10 1,8 LTA /9 11,2-11,8 KA s , M 8x , LTA /10 11,9-12,5 KA s 10 1,9 LTA /11 12,6-13,1 KA s 11 2,0 LTA /12 13,2-13,7 KA s 11 2,0 LTA ,8-14,4 F KA s ,4 LTA ,5-14,9 (Fig. 1) KA s ,4 LTA ,0-15,7 KA s , M 8x , LTA ,8-16,1 KA s ,6 LTA ,2-16,5 KA s ,6 LTA ,6-17,2 F 2787 KA s 11 3,4 LTA ,3-17,9 (Fig. 2) KA s , M 10x , LTA ,0-18,6 KA s 12 3,5 LTA ,7-19,3 KA s 12 3,5 LTA ,4-20,3 F 2698 KA s ,6 LTA ,4-21,3 (Fig. 2) KA s , M 10x , LTA ,4-22,2 KA s ,7 LTA ,3-23,1 KA s ,0 LTA ,2-23,7 F 2789 KA s ,9 LTA ,8-24,3 (Fig. 2) KA s , M 12x , LTA ,4-24,9 KA s ,3 LTA ,0-25,6 KA s ,3 LTA ,7-26,5 F 2730 KA s ,6 LTA ,6-27,4 (Fig. 2) KA s ,7 LTA ,5-28,3 KA s , M 12x , LTA ,4-29,2 KA s ,2 LTA ,3-29,9 KA s ,9 LTA ,0-30,6 KA s ,0 LTA ,70-31,14 F 2792 KA s 11 LTA ,15-31,74 (Fig. 2) KA s 11 LTA ,75-32,66 KA s , M 12x , LTA ,67-33,37 KA s 12 LTA ,38-34,43 KA s 12 s - Width across flats Helical rods: Aluminium alloy Clamp body: Aluminium alloy Straps: Steel, h.d.g. Bolt: Steel, h.d.g. Insert: Neoprene Stand: 06. November 2008 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment)/ 10 / 103

12 See data-sheet B800 Remarks: For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay direction on request (order example: LTA lis). For other executions please inquire. Stand: 06. November 2008 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment)/ 11 / 103

13 B801/2 Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment) 1... Clamp body with neoprene-insert 2... Helical rods 3... Fig Fig Attachment for shunts 6... Bolt 1 RIBE-Order-No. Clamping range RIBE-No. Helical rods a b Bolt 1 Mass/ I th F N (1+2) Clamp+Neoprene- Ribe-No. L Ø No. of rods Size s pcs mm Insert (1) mm mm mm mm mm kg ka kn LTA /18 9,0-9,7 B KA s 8 LTA /7 9,8-10,4 (Fig. 1) KA s 9 LTA /8 10,5-11,1 KA s 10 LTA /13 11,2-11,8 KA s , M 8x , LTA /14 11,9-12,5 KA s 10 LTA /15 12,6-13,1 KA s 11 LTA /16 13,2-13,7 KA s 11 LTA /6 13,8-14,4 F KA s ,1 LTA /7 14,5-14,9 (Fig. 1) KA s ,1 LTA /8 15,0-15,7 KA s , M 8x , LTA /9 15,8-16,1 KA s ,4 LTA /10 16,2-16,5 KA s ,4 LTA /5 16,6-17,2 F 2787 KA s 11 LTA /6 17,3-17,9 (Fig. 2) KA s , M 10x , LTA /7 18,0-18,6 KA s 12 LTA /8 18,7-19,3 KA s 12 LTA /5+9 19,4-20,3 F 2698 KA s ,2 LTA / ,4-21,3 (Fig. 2) KA s , M 10x , LTA / ,4-22,2 KA s ,4 LTA / ,3-23,1 KA s ,4 LTA /5+9 23,2-23,7 F 2789 KA s LTA / ,8-24,3 (Fig. 2) KA s , M 12x , LTA / ,4-24,9 KA s LTA / ,0-25,6 KA s LTA / ,7-26,5 F 2730 KA s ,7 LTA / ,6-27,4 (Fig. 2) KA s ,7 LTA / ,5-28,3 KA s , M 12x , LTA / ,4-29,2 KA s ,1 LTA / ,3-29,9 KA s ,1 LTA / ,0-30,6 KA s ,1 LTA / ,70-31,14 F 2792 KA s 11 LTA / ,15-31,74 (Fig. 2) KA s 11 LTA / ,75-32,66 KA s , M 12x , LTA / ,67-33,37 KA s 12 LTA / ,38-34,43 KA s 12 s - Width across flats Helical rods: Aluminium alloy Clamp body: Aluminium alloy Straps: Steel, h.d.g. Bolt: Steel, h.d.g. Insert: Neoprene Stand: 05. Juli 2010 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment)/ 12 / 103

14 See data-sheet B800 Remarks: For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay direction on request (order example: LTA /5 lis). Armour grip suspensions and shunts have to be ordered separately (shunts: see data-sheet B834/1 and B834/2). For other executions please inquire. Stand: 05. Juli 2010 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment)/ 13 / 103

15 B801/3 Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment, short version) 1... Clamp body with neoprene-insert 2... Helical rods 3... Fig Fig Bolt 1 RIBE-Order-No. Clamping range RIBE-No. Helical rods a b Bolt 1 Mass/ I th F N (1+2) Clamp+Neoprene- Ribe-No. L Ø No. of rods Size s pcs mm Insert (1) mm mm mm mm mm kg ka kn LTA /17 9,0-9,7 B KA LTA /5 9,8-10,4 (Fig. 1) KA LTA /6 10,5-11,1 KA LTA /9 11,2-11,8 KA , M 8x , LTA /10 11,9-12,5 KA LTA /11 12,6-13,1 KA LTA /12 13,2-13,7 KA LTA ,8-14,4 F KA ,1 LTA ,5-14,9 (Fig. 1) KA ,1 LTA ,0-15,7 KA , M 8x , LTA ,8-16,1 KA ,4 LTA ,2-16,5 KA ,4 LTA ,6-17,2 F 2787 KA LTA ,3-17,9 (Fig. 2) KA , M 10x , LTA ,0-18,6 KA LTA ,7-19,3 KA LTA ,4-20,3 F 2698 KA ,2 LTA ,4-21,3 (Fig. 2) KA , M 10x , LTA ,4-22,2 KA ,4 LTA ,3-23,1 KA ,4 LTA ,2-23,7 F 2789 KA LTA ,8-24,3 (Fig. 2) KA , M 12x , LTA ,4-24,9 KA LTA ,0-25,6 KA LTA ,7-26,5 F 2730 KA ,7 LTA ,6-27,4 (Fig. 2) KA ,7 LTA ,5-28,3 KA , M 12x , LTA ,4-29,2 KA ,1 LTA ,3-29,9 KA ,1 LTA ,0-30,6 KA ,1 LTA ,70-31,14 F 2792 KA ,2 LTA ,15-31,74 (Fig. 2) KA ,2 LTA ,75-32,66 KA , M 12x , LTA ,67-33,37 KA ,7 LTA ,38-34,43 KA ,7 s - Width across flats Helical rods: Alumnium alloy Clamp body: Aluminium alloy Straps: Steel, h.d.g. Bolt: Steel, h.d.g. Insert: Neoprene Stand: 25. Juli 2007 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment, short version)/ 14 / 103

16 See data-sheet B800 Remarks: For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay direction on request (order example: LTA /9 li). For other executions please inquire. Stand: 25. Juli 2007 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment, short version)/ 15 / 103

17 B801/4 Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment, short version) 1... Clamp body with neoprene-insert 2... Helical rods 3... Fig Fig Attachment for shunts 6... Bolt 1 RIBE-Order-No. Clamping range RIBE-No. Helical rods a b Bolt 1 Mass/ I th F N (1+2) Clamp+Neoprene- Ribe-No. L Ø No. of rods Size s pcs mm Insert (1) mm mm mm mm mm kg ka kn LTA /18 9,0-9,7 B KA LTA /7 9,8-10,4 (Fig. 1) KA LTA /8 10,5-11,1 KA LTA /13 11,2-11,8 KA , M 8x , LTA /14 11,9-12,5 KA LTA /15 12,6-13,1 KA LTA /16 13,2-13,7 KA LTA /6 13,8-14,4 F KA ,1 LTA /7 14,5-14,9 (Fig. 1) KA ,1 LTA /8 15,0-15,7 KA , M 8x , LTA /9 15,8-16,1 KA ,4 LTA /10 16,2-16,5 KA ,4 LTA /5 16,6-17,2 F 2787 KA LTA /6 17,3-17,9 (Fig. 2) KA , M 10x , LTA /7 18,0-18,6 KA LTA /8 18,7-19,3 KA LTA /5 19,4-20,3 F 2698 KA ,2 LTA /6 20,4-21,3 (Fig. 2) KA , M 10x , LTA /7 21,4-22,2 KA ,4 LTA /8 22,3-23,1 KA ,4 LTA /5+9 23,2-23,7 F 2789 KA LTA / ,8-24,3 (Fig. 2) KA , M 12x , LTA / ,4-24,9 KA LTA / ,0-25,6 KA LTA / ,7-26,5 F 2730 KA ,7 LTA / ,6-27,4 (Fig. 2) KA ,7 LTA / ,5-28,3 KA , M 12x , LTA / ,4-29,2 KA ,1 LTA / ,3-29,9 KA ,1 LTA / ,0-30,6 KA ,1 LTA / ,70-31,14 F 2792 KA ,2 LTA / ,15-31,74 (Fig. 2) KA ,2 LTA / ,75-32,66 KA , M 12x , LTA / ,67-33,37 KA ,7 LTA / ,38-34,43 KA ,7 s - Width across flats Helical rods: Alumnium alloy Clamp body: Aluminium alloy Straps: Steel, h.d.g. Bolt: Steel, h.d.g. Stand: 25. Juli 2007 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment, short version)/ 16 / 103

18 Insert: Neoprene See data-sheet B800 Remarks: For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay direction on request (order example: LTA /16 li). Armour grip suspensions and shunts have to be ordered separately (shunts: see data-sheet B834/1 and B834/2). For other executions please inquire. Stand: 25. Juli 2007 Pfad: RIBE-Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment, short version)/ 17 / 103

19 B803/1 C-shaped supports for armour grip suspensions F 1... Horizontal tensile force F 2... Vertical tensile force F 3... Horizontal tensile force rectangular to the line direction RIBE-Order-No. Minimum Failure Load* Mass/pcs d 1 d 2 F 1 F 2 F 3 mm mm kn kn kn κγ F /1 13,5 20 F /2 15,0 20 F /3 18,0 20 F /4 20,5 20 F /5 13, ,4 F /6 15,0 24 F /7 18,0 24 F /8 20,5 24 F /9 24,0 20 * Specified Minimum Failure Loads for bolts and nuts 8.8 h.d.g. Support: Cast steel, h.d.g. Pivotal joints: Cast steel, h.d.g. Pin: Stainless steel C-shaped supports are preferably used on the top of suspension towers to suspend ground wires and optical fibre aerial cables. The attachment of the suspension clamp is made by a cardanic joint which assures universal movement of the suspension fitting. The mechanical behaviour of the suspension is almost identical to that of the conductor suspension in suspension sets. The C-shaped support is resistant to short-circuit. Additionally articulation points can be thermically relieved by using shunts. C-shaped supports can also be installed with insulation. For that the insulation set RIBE-No is required. The connection for suspension clamps correponds to LA/ LB 19 or 22 to DIN , i.e. all customary suspension clamps with strap widths according to GA/ GB 19 or 22 can be inserted without changing of straps. Because of its C-shape, the support permits the suspension clamp to pivot up to 45. Stand: 26. Juni 2006 Pfad: RIBE-Optofit/ Suspension fittings/ C-shaped supports for armour grip suspensions/ 18 / 103

20 Fig.: Mounting example C-shaped support and armour grip suspension Remarks: Bolts for tower connection of the support are included only upon special request with indication of required bolt dimension. Armour grip suspensions and C-shaped supports have to be ordered separately (armour grip suspensions for C-shaped support: see data-sheet B801 ff.) For other executions please inquire. Stand: 26. Juni 2006 Pfad: RIBE-Optofit/ Suspension fittings/ C-shaped supports for armour grip suspensions/ 19 / 103

21 B804/4 Suspension supports without shunt attachment (special design) 1... Bolts RIBE-Order-No. Clamping range Helical rods Bolts mm B /14 9,0-9,7 KA lis M16 B /7 9,8-10,4 KA lis M16 B /8 10,5-11,1 KA lis M16 B /9 11,2-11,8 KA lis M16 B /10 11,9-12,5 KA lis M16 B /11 12,6-13,1 KA lis M16 B /12 13,2-13,7 KA lis M16 B /6 13,8-14,4 KA lis M16 B /7 14,5-14,9 KA lis M16 B /8 15,0-15,7 KA lis M16 B /9 15,8-16,1 KA lis M16 B /10 16,2-16,5 KA lis M16 B /5 16,6 17,2 KA lis M16 B /6 17,3 17,9 KA lis M16 B /7 18,0 18,6 KA lis M16 B /8 18,7 19,3 KA lis M16 Support: Steel, h.d.g. Helical rods: Alumimium alloy Suspension supports are preferably installed on the top of suspension towers and are used for the suspension of ground wires and optical fibre aerial cables. The suspension support is resistant to short-circuit. Additionally articulation points can be thermically relieved by shunts. Remark: Bolts for tower connection of the support are included only upon request with indication of required bolt dimension. Stand: 03. Mai 2007 Pfad: RIBE-Optofit/ Suspension fittings/ Suspension supports without shunt attachment (special design)/ 20 / 103

22 B804/5 Suspension supports with shunt attachment (special design) 1... Bolts RIBE-Order-No. Clamping range Helical rods Bolts Shunt mm B /13 9,0-9,7 KA lis M B /1 9,8-10,4 KA lis M B /2 10,5-11,1 KA lis M B /3 11,2-11,8 KA lis M B /4 11,9-12,5 KA lis M B /5 12,6-13,1 KA lis M B /6 13,2-13,7 KA lis M B /1 13,8-14,4 KA lis M B /2 14,5-14,9 KA lis M B /3 15,0-15,7 KA lis M B /4 15,8-16,1 KA lis M B /5 16,2-16,5 KA lis M B /1 16,6 17,2 KA lis M B /2 17,3 17,9 KA lis M B /3 18,0 18,6 KA lis M B /4 18,7 19,3 KA lis M Support: Steel, h.d.g. Helical rods: Aluminium rods Shunt: Copper Suspension supports are preferably installed on the top of suspension towers and are used for the suspension of ground wires and optical fibre aerial cables. The suspension support is resistant to short-circuit. Additionally articulation points can be thermically relieved by shunts. Remarks: Bolts for tower connection of the support are included only upon request with indication of required bolt dimension. Suspension supports and shunts have to be ordered separately. Shunts: see data-sheet B834/1 and B834/2 Stand: 03. Mai 2007 Pfad: RIBE-Optofit/ Suspension fittings/ Suspension supports with shunt attachment (special design)/ 21 / 103

23 B805/2 Suspension rods for ADSS cable and medium span lengths from m 1... Suspension rods 2... Thimble 3... Protection rods RIBE-Order-No. Clamping range Dia. of rods L No. of rods Thimble Mass/ pcs mm mm mm kg TG ,00-12,72 3, E ,21 TG ,73-13,49 3, E ,22 TG ,50-14,31 3, E ,22 TG ,32-15,18 3, E ,23 TG ,19-16,11 3, E ,23 TG ,12-17,08 3, E ,24 TG ,09-18,12 3, F ,50 TG ,13-19,22 3, F ,51 TG ,23-20,38 3, F ,51 TG ,39-21,61 3, F ,52 TG ,62-22,92 3, F ,53 TG ,93-24,31 3, F ,65 TG ,32-25,77 4, F ,88 TG ,78-27,33 4, F ,90 TG ,34-28,98 4, F ,21 TG ,99-30,73 4, F ,23 Helical rods: Steel, h.d.g. Suspension rods consisting of TG-suspension and UTA-protection rods are designed for vertical loads up to 5 kn. They are used for span lengths from m approximately. The loop of the TG-suspension rods is stabilized and protected against abrasion by a ring type thimble. Fig.: Mounting example 1... Protection rods 2... Hook 3... Suspension rods Remarks: Ring type thimbles (see data-sheet B823), UTA-protection rods (see data-sheet B814/2) and TG-suspension rods have to be ordered separately. When selecting the suspension rods it must be considered that the total diameter results from the cable diameter plus two times the rod diameter of protection rods. Installation instructions see data-sheet Mon69. Stand: 10. August 2006 Pfad: RIBE-Optofit/ Suspension fittings/suspension rods for ADSS cable and medium span lengths from m/ 22 / 103

24 B805/3 Pulley clamps with spiral attachment for ADSS cable, span lengths up to 150 m and tensile forces up to 2,5 kn 1... Helical rods 2... Suspension pulley RIBE-Order-No. Clamping range Helical rods Dia. of rods L No. of rods Mass/ pcs mm mm mm kg F /01 7,65-8,45 HRG , ,19 F /02 8,46-9,26 HRG , ,26 F /03 9,27-10,27 HRG , ,24 F /04 10,28-11,30 HRG , ,26 F /05 11,31-12,35 HRG , ,56 F /06 12,36-13,41 HRG , ,53 F /07 13,42-14,49 HRG , ,58 F /08 14,50-15,60 HRG , ,82 F /09 15,61-16,71 HRG , ,89 F /10 16,72-17,82 HRG , ,93 F /11 17,83-18,90 HRG , ,97 F /12 18,94-20,24 HRG , ,01 F /13 20,25-21,55 HRG , ,05 F /14 21,56-22,86 HRG , ,09 Helical rods: Steel, h.d.g. Pulley clamps with spiral attachment are designed for span lengths up to 150 m approximately and tensile forces up to 2,5 kn. Stand: 18. August 2006 Pfad: RIBE-Optofit/ Suspension fittings/ Pulley clamps with spiral attachment for ADSS cable, span lengths up to 150 m and tensile forces up to 2,5 kn/ 23 / 103

25 B805/5 Suspension rods for ADSS cable and short span lengths up to 70 m 1... Suspension rods 2... Thimble 3... Supporting rods RIBE-Order-No. Clamping range Dia. of rods L TG L LG No. of rods Thimble Mass/ pcs TG LG TG LG mm mm mm mm kg kg TG LG s 6,91-7,5 2, E ,10 0,06 TG LG s 7,51-8,2 2, E ,14 0,08 TG LG s 8,21-8,8 2, E ,14 0,08 TG LG s 8,81-9,5 2, E ,14 0,08 TG LG s 9,51-10,2 2, E ,14 0,08 TG LG s 10,21-10,8 3, E ,21 0,11 TG LG s 10,81-11,4 3, E ,21 0,12 TG LG s 11,41-12,0 3, E ,21 0,12 TG LG s 12,01-12,6 3, E ,22 0,12 TG LG s 12,61-13,2 3, E ,22 0,12 TG LG s 13,21-13,8 3, E ,22 0,12 TG LG s 13,81-14,4 3, E ,22 0,13 TG LG s 14,41-15,0 3, E ,22 0,13 TG LG s 15,01-15,6 3, E ,23 0,13 TG LG s 15,61-16,2 3, E ,23 0,13 TG LG s 16,21-16,8 3, F ,36 0,18 TG LG s 16,81-17,4 3, F ,36 0,18 TG LG s 17,41-18,0 3, F ,36 0,18 TG LG s 18,01-18,6 3, F ,37 0,18 TG LG s 18,61-19,2 3, F ,37 0,19 TG LG s 19,21-19,8 3, F ,37 0,19 TG LG s 19,81-20,4 3, F ,38 0,19 TG LG s 20,41-21,0 3, F ,38 0,19 TG LG s 21,01-21,6 3, F ,39 0,19 TG LG s 21,61-22,2 3, F ,39 0,19 Helical rods: Steel, h.d.g. Suspension rods consisting of thimble, LG- and TG-helical rods are designed for vertical loads up to 1kN. They are used for span lengths up to 70 m approximately. The TG-suspension rods with the preformed loop is the supporting accessory. The shorter and straight LG-supporting rods are only used for stiffening the area round the suspension point. The loop of the fitting is stabilized and protected against abrasion with a ring type thimble. Stand: 18. August 2006 Pfad: RIBE-Optofit/ Suspension fittings/ Suspension rods for ADSS cable and short span lengths up to 70 m/ 24 / 103

26 Fig.: Mountimg example 1... Suspension rods 2... Hook Remarks: Ring type thimbles see data-sheet B823. TG-suspension rods and LG-supporting rods have to be ordered separately. Mounting instruction see data-sheet Mon51. Stand: 18. August 2006 Pfad: RIBE-Optofit/ Suspension fittings/ Suspension rods for ADSS cable and short span lengths up to 70 m/ 25 / 103

27 B806/1 Suspension pulleys for ADSS 1... ADSS cable RIBE-Order-No. Diameter of ADSS cable a mm Rated force F N kn F = ,40 F /1 = ,97 F /2 = ,97 b mm c mm Mass / pcs kg Roll: Polyamid Straps: Steel, h.d.g. Bolt, nut: h.d.g., alternatively stainless steel Suspension pulleys are used for suspension of ADSS cables (preferably at wooden pole or concrete pole - see figure below). The suspension pulleys benefit from the fact that in case of a tree falling in the span length the ADSS cable is not destroyed. This has no influence on the communication line. To avoid high compression forces at the point of contact between cable and suspension pulleys the use of protection rods is recommended. Fig.: Mounting example 1... Wooden pole 2... Thimble 3... Hook 4... Helical dead end 5... Suspension pulley 6... Protection rods 7... ADSS Remark: For other executions please inquire. Stand: 18. August 2006 Pfad: RIBE-Optofit/ Suspension fittings/ Suspension pulleys for ADSS/ 26 / 103

28 B810/0 Introduction to helical dead ends 1... Helical dead end 2... Thimble 3... Black crossing mark Design and performance: Helical dead ends are ideally suited for the full tensioning of self supporting optical fibre aerial cables. Dead ends are composed of five or more preassembled helical rods which are covered with a small-grained sand on the inside to improve the frictional contact. The loop of the dead end is protected from abrasion by means of a thimble. The deformation of the cable is omitted as the radial compression is distributed over a large contact area. The helical rods are made of a high-tensile, corrosion-resistant aluminium alloy, of high-tensile hot-dip galvanized steel, or Aluminium-clad steel; thimbles of hot-dip galvanized malleable cast iron and cotter pins or threaded bolts of hot-dip galvanized steel with tensile strength class 8.8. Installation: The legs of the dead end are wrapped on the cable starting at the marked crossing point. Special tooling is not required. For installation follow RIBE-Mounting Instruction No. 9. Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ Introduction to helical dead ends/ 27 / 103

29 B811 AW-Helical dead ends for OPGW, ADSS and ACSR 1... Helical dead end 2... Thimble 3... Black crossing mark RIBE-Order-No. Clamping range Dia. of rods L 1 L 2 No. of Thimble Mass/ piece mm mm mm mm rods RIBE-No. kg AW ,56-5,84 2, ,16 AW ,85-6,11 2, ,16 AW ,12-6,36 2, ,17 AW s 6,61-6,84 2, F 2684/3 0,24 AW ,85-7,12 2, ,17 AW ,13-7,68 2, ,23 AW ,69-7,95 2, ,24 AW ,91-8,23 2, ,25 AW ,71-9,02 2, ,36 AW ,47-9,95 3, ,40 AW ,65-10,00 3, ,50 AW ,01-10,45 3, ,51 AW ,46-10,84 3, F 2684/3 0,64 AW ,85-11,23 3, or 0,70 AW s 11,24-11,70 3, F 2685/3 0,88 AW ,50-12,10 3, ,70 AW ,11-12,80 3, ,71 AW ,81-13,39 3, ,75 AW ,40-14,40 3, ,75 AW ,50-16,50 3, ,74 AW s 14,50-16,50 4, ,50 AW ,20-17,20 3, ,76 AW s 16,51-17,79 4, ,92 AW ,30-19,30 3, F 2685/3 1,08 AW ,30-19,30 4, ,73 AW s 17,60-18,80 4, ,04 AW ,40-21,40 4, ,10 AW ,50-22,50 4, ,22 AW ,70-23,70 4, ,66 AW ,20-25,20 4, ,58 AW ,00-27,00 4, F 2686/2 3,40 AW ,50-28,50 4, ,50 AW ,50-30,60 4, ,70 AW ,60-32,60 4, ,35 AW ,10-34,10 4, ,05 AW ,00-35,00 5, ,60 AW ,00-37,00 5, ,18 AW ,00-39,00 5, ,90 Helical rods: Aluminium-clad steel Stand: 25. Juli 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ AW-Helical dead ends for OPGW, ADSS and ACSR/ 28 / 103

30 Thimble: Malleable cast iron, h.d.g. See data-sheet B810 Remarks: When selecting helical dead ends the total diameter resulting from the cable diameter plus two times the rod diameter of the protection rods has to be taken into account. Furthermore the rated forces of thimbles are observed (see data-sheet B821). For installation follow RIBE-Mounting Instruction No. 9. These dead end designs are only suitable for cables or conductors with right-hand lay armoring and ADSS cables. If dead ends for left-hand lay cables or conductors are required this must specifically be stated when placing the order. Order example: AW li Thimbles: see data-sheet B821 Stand: 25. Juli 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ AW-Helical dead ends for OPGW, ADSS and ACSR/ 29 / 103

31 B812 RW-Protection rods RIBE-Order-No. Clamping range Dia. of rods L No. of rods Rod subsets Sanding Mass/ pcs mm mm mm kg RW lis 8,0-9,0 2, x 0,60 RW lis 8,0-9,0 2, x 0,68 RW lis 8,0-9,0 2, x 1,01 RW lis 9,1-10,1 2, x 0,65 RW lis 9,1-10,1 2, x 0,74 RW lis 9,1-10,1 2, x 0,83 RW lis 9,1-10,1 2, x 0,68 RW lis 9,1-10,1 2, x 1,11 RW lis 10,2-11,2 2, x 0,76 RW lis 10,2-11,2 2, x 0,80 RW lis 10,2-11,2 2, x 1,00 RW lis 10,2-11,2 2, x 1,10 RW lis 10,2-11,2 2, x 1,20 RW lis 11,3-11,75 3, x 1,34 RW lis 11,5-11,75 3, x 1,50 RW lis 11,5-11,75 3, x 1,71 RW lis 11,5-11,75 3, x 2,23 RW lis 11,3-12,3 2, ,64 RW lis 11,3-12,3 2, x 0,89 RW lis 11,3-12,3 2, x 1,08 RW lis 11,3-12,3 2, x 1,11 RW lis 11,3-12,3 2, x 1,30 RW lis 11,3-12,3 2, x 1,50 RW lis 11,3-12,3 2, x 1,91 RW lis 11,3-12,3 2, x 2,42 RW lis 12,4-13,4 2, ,48 RW lis 12,4-13,4 2, x 0,76 RW lis 12,4-13,4 2, x 0,96 RW lis 12,4-13,4 2, x 1,08 RW lis 12,4-13,4 2, x 1,24 RW lis 12,4-13,4 2, x 1,42 RW lis 12,4-13,4 2, x 1,62 RW lis 12,4-13,4 2, x 2,03 RW lis 13,5-14,4 3, ,70 RW lis 13,5-14,4 3, ,86 RW lis 13,5-14,4 3, ,04 RW lis 13,5-14,4 3, x 1,56 RW lis 13,5-14,4 3, x 1,73 RW lis 13,5-14,4 3, x 2,20 RW lis 13,5-14,4 3, x 2,51 RW lis 13,5-14,4 3, x 2,77 RW lis 13,5-14,4 3, x 4,23 RW lis 13,5-14,4 3, ,54 RW lis 13,8-14,8 3, ,60 RW lis 13,8-14,8 3, x 1,72 RW lis 13,8-14,8 3, x 2,25 RW lis 13,8-14,8 3, x 2,58 RW lis 14,5-16,5 3, ,65 RW lis 14,5-16,5 3, ,93 RW lis 14,5-16,5 3, ,11 RW lis 14,5-16,5 3, x 1,85 RW lis 14,5-16,5 3, x 2,55 RW lis 14,5-16,5 3, x 2,95 RW lis 14,5-16,5 3, x 3,89 RW lis 14,5-16,5 3, x 4,64 RW lis 16,0-16,9 3, x 1,98 RW lis 16,0-16,9 3, x 2,78 RW lis 17,0-17,6 3, ,27 RW lis 17,0-17,6 3, x 2,10 RW lis 17,0-17,6 3, x 2,73 RW lis 17,0-17,6 3, x 2,94 Stand: 12. Mai 2010 Pfad: RIBE-Optofit/ Fittings for tension towers/ RW-Protection rods/ 30 / 103

32 RIBE-Order-No. Clamping range Dia. of rods L No. of rods Rod subsets Sanding Mass/ pcs mm mm mm kg RW lis 17,0-17,6 3, x 3,15 RW lis 17,3-19,3 3, ,74 RW lis 17,3-19,3 3, ,05 RW lis 17,3-19,3 3, ,15 RW lis 17,3-19,3 3, ,26 RW lis 17,3-19,3 3, x 1,57 RW lis 17,3-19,3 3, x 2,10 RW lis 17,3-19,3 3, x 2,20 RW lis 17,3-19,3 3, ,30 RW lis 17,3-19,3 3, x 2,80 RW lis 17,3-19,3 3, x 3,04 RW lis 17,3-19,3 3, x 3,27 RW lis 17,3-19,3 3, x 4,22 RW lis 17,3-19,3 3, ,62 RW lis 17,3-19,3 3, ,83 RW lis 17,3-19,3 3, ,77 RW lis 19,4-21,4 4, ,28 RW lis 19,4-21,4 4, ,92 RW lis 19,4-21,4 4, x 4,40 RW lis 19,4-21,4 4, x 5,50 RW lis 19,4-21,4 4, x 6,16 RW lis 19,4-21,4 4, ,71 Rw lis 20,5-22,5 4, ,31 RW lis 20,5-22,5 4, ,24 RW lis 20,5-22,5 4, x 2,80 RW lis 20,5-22,5 4, x 4,67 RW lis 20,5-22,5 4, x 5,79 RW lis 20,5-22,5 4, x 6,54 Rw lis 20,5-22,5 4, x 9,51 RW lis 21,7-23,7 4, ,40 RW lis 21,7-23,7 4, ,00 RW lis 21,7-23,7 4, ,40 RW lis 21,7-23,7 4, x 3,90 RW lis 21,7-23,7 4, x 4,68 RW lis 21,7-23,7 3, x 4,00 RW lis 21,7-23,7 4, x 6,20 RW lis 21,7-23,7 4, x 6,60 RW lis 21,7-23,7 4, x 7,00 RW lis 21,7-23,7 4, x 9,40 RW lis 23,8-25,2 4, x 1,47 RW lis 23,8-25,2 4, x 2,10 RW lis 23,8-25,2 4, ,55 RW lis 23,8-25,2 4, x 5,31 RW lis 23,8-25,2 4, x 6,50 RW lis 23,8-25,2 4, x 7,30 RW lis 23,8-25,2 4, x 10,30 RW lis 25,0-27,0 4, ,53 RW lis 25,0-27,0 4, ,63 RW lis 25,0-27,0 4, x 6,80 RW lis 25,0-27,0 4, x 7,65 RW lis 26,5-28,5 4, x 9,40 RW lis 28,5-30,6 4, ,73 RW lis 28,5-30,6 4, ,96 RW lis 28,5-30,6 4, x 8,16 RW lis 28,5-30,6 4, x 9,40 RW lis 28,5-30,6 4, x 9,80 RW lis 30,6-32,6 4, x 9,22 Helical rods: Aluminium-clad steel Protection rods are preferably made of Aluminium-clad steel-wires and shall protect the self supporting fibre optical aerial cables at tension sets. They are mounted beneath the helical dead end and spread the radial forces on the cable uniformly along the zone of contact. Especially on the cable at the loop-side of the helical dead end radial forces (depending on the tension force) can stress the optical part of the cable inadmissibly. This will cause high damping which results in a reduced data transmission or in the worst case an interruption. The length of the cable guard is determined in such a way that two vibration dampers can be mounted on the rods at the span-side avoiding that the damper clamp is stressing the optical part of the cable. For optical fibre aerial cables with right-hand outer layer, cableguards with left-hand layer are always used in order to avoid a torsion of the cable by the helical dead end with right-hand layer. A torsion of the aerial cable is causing an enlenghtening leading to a destruction of the optical part of the cable. Installation: The helical rods can be wrapped on by hand in bundles. Tools are not required for the assembly. Prior to installation the cable must be cleaned along the overall lenght of Stand: 12. Mai 2010 Pfad: RIBE-Optofit/ Fittings for tension towers/ RW-Protection rods/ 31 / 103

33 protection rods. Fig.: Mounting example 1... Thimble 2... Protection rods 3... Helical dead end Remarks: These protection rods designs are only suitable for cables with right-hand lay armoring and ADSS cables. If dead ends for left-hand lay cables are required this must be specifically stated when placing the order. Order example: RW s Stand: 12. Mai 2010 Pfad: RIBE-Optofit/ Fittings for tension towers/ RW-Protection rods/ 32 / 103

34 B813/1 Helical dead ends (AG) for OPGW 1... Helical dead end 2... Thimble 3... Black crossing mark RIBE-Order-No. Clamping range mm Dia. of rods L 1 mm L 2 mm No. of rods Thimble RIBE-No. AG ,5-16,5 2, ,72 AG ,2-17,2 2, ,78 AG ,3-19,3 3, F 2685/3 1,16 AG ,4-21,4 3, ,38 AG ,5-22,5 3, ,59 AG ,7-23,7 3, ,03 AG ,2-25,2 3, ,39 AG ,0-27,0 3, F 2686/2 2,51 AG ,5-28,5 3, ,94 AG ,5-30,5 3, ,17 AG ,6-32,6 4, F 3246/2 Mass/ pcs kg Helical rods: Steel, h.d.g. Thimble: Malleable cast iron, h.d.g. See data-sheet B810 Remarks: When selecting the helical dead ends the total diameter resulting out of the cable diameter plus two times the rod diameter of the protection rods has to be taken into account. Furthermore the rated forces of thimbles are observed (see data-sheet B821). For installation follow RIBE-Mounting Instruction No. 9. These dead end designs are only suitable for cables of right-hand lay armoring. If dead ends for left-hand lay cables are required this must be specifically stated when placing the order. Order example: AG lis Thimbles: see data-sheet B821 Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ Helical dead ends (AG) for OPGW/ 33 / 103

35 B813/2 AG-Helical dead ends for short span lengths (up to 70 m) and ADSS 1... Thimble 2... Helical dead end 3... Black crossing mark RIBE-Orderno. Clamping range Dia. of rods L No. of rods Thimble Thimble Mass/pcs mm mm mm Sheet metal casted kg AG s 7,71-8,31 2, B ,10 AG s 8,32-8,99 2, B ,15 AG s 9,00-9,72 2, B ,16 AG s 9,73-10,51 2, B ,17 AG s 10,52-11,36 2, B ,23 AG s 11,37-12,28 3, B ,28 AG s 12,29-13,27 3, F F 2685/3 0,35 AG s 13,28-14,35 3, F F 2685/3 0,38 AG s 14,36-15,50 3, F F 2685/3 0,56 AG s 15,51-16,75 3, F F 2685/3 0,60 AG s 16,76-18,11 3, F F 2685/3 0,65 AG s 18,12-19,57 3, F F 2685/3 0,70 AG s 19,58-21,14 3, F F 2685/3 0,90 AG s 21,15-22,84 3, F F 2685/3 0,97 AG s 22,85-24,68 3, after inquiry F 2685/3 1,22 AG s 24,69-26,67 3, after inquiry F 2685/3 1,32 AG s 26,68-28,80 3, after inquiry F 2685/3 1,64 Helical rods: Steel, h.d.g. Thimble: Steel,h.d.g.; malleable cast iron, h.d.g. These dead ends are designed for the full tensioning of ADSS cables in short span lengths up to 70 m. The loop of the dead end can be protected against abrasion by a thimble. Fig.: Mounting example Remarks: For installation follow RIBE-Mounting Instruction No. 9. Furthermore the rated forces of thimbles are observed (see data-sheet B821). Thimbles: see data-sheet B821-B822 Stand: 07. Oktober 2008 Pfad: RIBE-Optofit/ Fittings for tension towers/ AG-Helical dead ends for short span lengths (up to 70 m) and ADSS/ 34 / 103

36 B813/3 AG-Helical dead ends for all span lengths 1... Helical dead end 2... Red crossing mark 3... Black crossing mark RIBE-Order-No. Clamping range mm Dia. of rods mm L mm No. of rods Thimble Sheet metal AG s 9,00-9,72 2, B ,21 AG s 9,73-10,51 2, B ,23 AG s 10,52-11,36 2, B ,29 AG s 11,37-12,28 3, B ,38 AG s 12,29-13,27 3, F F 2685/3 0,48 AG s 13,28-14,35 3, F F 2685/3 0,52 AG s 14,36-15,50 3, F F 2685/3 0,76 AG s 15,51-16,75 3, F F 2685/3 0,82 AG s 16,76-18,11 3, F F 2685/3 0,88 AG s 18,12-19,57 3, F F 2685/3 0,96 AG s 19,58-21,14 3, F F 2685/3 1,23 AG s 21,15-22,84 3, F F 2685/3 1,33 AG s 22,85-24,68 3, F F 2685/3 1,68 AG s 24,69-26,67 3, F F 2685/3 1,81 AG s 26,68-28,81 3, F F 2685/3 2,23 AG s 28,82-31,13 3, F F 2685/3 2,41 Thimble casted Mass/ pcs kg Helical rods: Steel, h.d.g. Thimble: Steel, h.d.g.; malleable cast iron, h.d.g. These dead ends are particulary designed for the full tensioning of ADSS cable in short, medium and long spans. Three ways of application are possible: for short spans (up to approx. 70m) and small forces: : The dead end is mounted on the cable starting at the black crossing mark. This leads to a long cable loop and a large bending radius of the cable. A thimble can be used in the loop of the dead end. for medium spans (approx m) and high forces: Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ AG-Helical dead ends for all span lengths/ 35 / 103

37 The dead end is mounted on the cable starting at the red crossing mark. This leads to a short cable loop. Additional intermediate fittings for installation at the tower and a thimble are necessary. for long spans and high forces: The use of protection rods (URA: see data-sheet B814/1) is recommended. When selecting the helical dead ends the total diameter resulting out of the cable diameter plus two times the rod diameter of protection rods has to be taken into account. Remarks: For installation follow RIBE-Mounting Instruction No. 9. Furthermore the rated forces of thimbles are observed (see data-sheet B821). Sheet thimbles: see data-sheet B822 Casted thimbles: see data-sheet B821 Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ AG-Helical dead ends for all span lengths/ 36 / 103

38 B813/4 AG-Helical dead ends for Figure-8-cables with separate left-hand layer support 1... Helical dead end 2... Supporting cable 3... Black crossing mark RIBE-Order-No. For steel support cable Color of marker Dia. of rods L No. of rods Mass/ pcs No. of wires Dia. without insulation mm mm mm kg AG li 7 x 1,0 mm 3,0 black 1, ,04 AG li 10 x 1,0 mm 4,0 yellow 1, ,07 AG li 14 x 1,0 mm 4,4 blue 1, ,08 AG li 19 x 1,0 mm 5,0 red 2, ,14 AG li 19 x 1,2 mm 6,0 green 2, ,20 AG li 19 x 1,5 mm 7,5 orange 2, ,31 Helical rods: Steel, h.d.g. These dead ends are designed for the full tensioning of the separate support cable (left-hand outer layer). The advantage of dead ends compared with tensioning devices commonly used is that there is no bending of the relatively stiff supporting cable. It is recommended to protect the dead end loop from abrasion by means of a thimble. These dead ends can be used to suspend self supporting figure-8-cables too. Two dead ends per suspension point are required for any such application (see figure below). Fig.: Mounting example for suspending self supporting cables Installation: Dead ends can be installed and removed quickly and without application of any tools. Wrapping of dead ends starts at the crossing mark. For installation follow RIBE-Mounting Instruction No. 9. Remarks: These dead end designs are only suitable for left-hand layer steel support cables. When placing an order please state if dead ends for righthand layer support cables are required. Thimbles: see data-sheet B822 Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ AG-Helical dead ends for Figure-8-cables with separate left-hand layer support/ 37 / 103

39 B813/6 AG-Helical dead ends 1... Helical dead end 2... Thimble 3... Black crossing mark RIBE-Order-No. Clamping range Dia. of rods L 1 mm mm AG s 11,50-12,13 3, ,62 AG s 12,14-12,81 3, F 2685/3 0,79 AG s 12,82-13,53 3, ,84 AG s 13,54-14,28 3, ,88 AG s 14,29-15,08 3, ,93 AG s 15,09-15,92 3, ,97 AG s 15,93-16,80 3, ,96 AG s 16,81-17,74 3, F 2685/3 1,01 AG s 17,75-18,72 3, ,25 AG s 18,73-19,76 3, ,32 AG s 19,77-20,86 4, ,86 AG s 20,87-22,02 4, ,95 AG s 22,03-23,24 4, ,06 AG s 23,25-24,53 4, ,54 AG s 24,54-25,89 4, F 2686/2 2,67 AG s 25,90-27,32 4, ,81 AG s 27,33-28,84 4, ,39 AG s 28,85-30,43 4, ,58 AG s 30,44-32,12 4, ,24 AG s 32,13-33,89 4, F 3246/2 4,47 AG s 33,90-35,77 5, ,38 AG s 35,78-37,75 5, ,78 L 2 No. of rods Thimble RIBE-No. Mass/ pcs kg Helical rods: Steel, h.d.g. Thimble: Malleable cast iron, h.d.g. See data-sheet B810 Remarks: When selecting helical dead ends the total diameter resulting from the cable diameter plus two times the rod diameter of the protection rods has to be taken into account. Furthermore the rated forces of thimbles are observed (see data-sheet B821). For installation follow RIBE-Mounting Instruction No. 9. These dead end designs are only suitable for cables with right-hand lay armoring and ADSS cables. If dead ends for left-hand lay cables are required this must specifically be stated when placing the order. Order example: AG s Thimbles: see data-sheet B821 Stand: 04. Mai 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ AG-Helical dead ends/ 38 / 103

40 B814/1 URA-Protection rods for ADSS cables and spans longer than 150 m RIBE-Order-No. Clamping range Dia. of rods No. of rods Subsets Mass/ pcs mm mm mm kg URA lis 7,35-7,79 2, ,17 URA lis 7,80-8,27 2, ,18 URA lis 8,28-8,78 2, ,20 URA lis 8,79-9,31 2, ,21 URA lis 9,32-9,88 2, ,23 URA lis 9,89-10,49 2, ,26 URA lis 10,50-11,13 3, ,37 URA lis 11,14-11,80 3, ,38 URA lis 11,81-12,52 3, ,43 URA lis 12,53-13,28 3, ,44 URA lis 13,29-14,09 3, ,60 URA lis 14,10-14,95 3, ,67 URA lis 14,96-15,86 3, ,69 URA lis 15,87-16,82 3, ,77 URA lis 16,83-17,84 3, ,94 URA lis 17,85-18,92 3, ,04 URA lis 18,93-20,06 3, ,08 URA lis 20,07-21,28 3, ,20 URA lis 21,29-22,57 3, ,32 Helical rods: Aluminium alloy Cable guards protect the ADSS cables at the tension assembly. They are mounted under the helical dead end and reduce the radial forces in the cable - especially at the loopside of the dead end. Radial forces (depending on the tension force) can stress the optical part of the cable inadmissibly. This can cause high damping in the optical fibre. This results in a high signal damping in the optical fibre up to an interruption of the optical transmission. Installation: The helical rods can be wrapped on by hand in bundles. Tools are not required for installation. Fig.: Mounting example 1... Thimble 2... Protection rods 3... Helical dead end Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ URA-Protection rods for ADSS cables and spans longer than 150 m/ 39 / 103

41 Remarks: Helical dead ends: see data-sheet B813/3 Order example: URA lis Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ URA-Protection rods for ADSS cables and spans longer than 150 m/ 40 / 103

42 B814/2 UTA-Protection rods for ADSS cables and medium span lengths ( m) RIBE-Order-No. Clamping range Dia. of rods No. of rods Subsets Mass/ pcs mm mm mm kg UTA lis 7,35-7,79 2, ,20 UTA lis 7,80-8,27 2, ,20 UTA lis 8,28-8,78 2, ,22 UTA lis 8,79-9,31 2, ,22 UTA lis 9,32-9,88 2, ,24 UTA lis 9,89-10,49 2, ,27 UTA lis 10,50-11,13 3, ,43 UTA lis 11,14-11,80 3, ,43 UTA lis 11,81-12,52 3, ,47 UTA lis 12,53-13,28 3, ,48 UTA lis 13,29-14,09 3, ,62 UTA lis 14,10-14,95 3, ,67 UTA lis 14,96-15,86 3, ,68 UTA lis 15,87-16,82 3, ,94 UTA lis 16,83-17,84 3, ,09 UTA lis 17,85-18,92 3, ,63 UTA lis 18,93-20,06 3, ,65 UTA lis 20,07-21,28 3, ,77 Helical rods: Aluminium alloy Protection rods are mounted under the suspension rods to protect the ADSS cable. They reduce radial forces in the cable and increase - due to the increased bending stiffness - the bending radius of the ADSS cable. Installation: The helical rods can be wrapped on by hand in bundles. Tools are not required for installation. Fig.: Mounting example 1... UTA-Protection rods 2... Hook 3... TG-Suspension rods Remarks: Order example: UTA lis Suspension rods: see data-sheet B805/2 Installation instructions: see data-sheet Mon69 Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ UTA-Protection rods for ADSS cables and medium span lengths ( m)/ 41 / 103

43 B814/3 Patch rods RIBE-Order-No. Clamping range Dia. of rods L No. of rods Subsets Mass/ pcs mm mm mm kg RA s 7,35 7,79 2, (*) 0,18 RA s 7,80-8,27 2, (*) 0,18 RA s 8,28 8,78 2, (*) 0,21 RA s 8,79-9,31 2, (*) 0,21 RA s 9,32 9,88 3, (*) 0,28 RA s 9,89 10,49 3, (*) 0,32 RA s 10,50 11,13 3, (*) 0,43 RA s 11,14-11,80 3, (*) 0,44 RA s 11,81 12,52 3, (*) 0,46 RA s 12,53 13,28 4, (*) 0,66 RA s 13,29 14,09 4, (*) 0,75 RA s 14,10 14,95 4, (*) 0,93 RA s 14,96 15,86 4, (*) 0,97 RA s 15,87 16,82 4, (*) 1,10 RA s 16,83 17,84 5, (*) 1,33 RA s 17,85 18,92 6, (*) 1,91 RA s 18,93 20,06 6, (*) 1,99 RA s 20,07 21,28 6, (*) 2,29 RA s 21,29 22,57 6, (*) 2,39 RA s 22,58 23,93 7, (**) 3,52 RA s 23,94 25,38 7, (**) 3,68 RA s 25,39 26,91 7, (**) 4,24 RA s 26,92 28,54 9, (**) 5,63 RA s 28,55 30,26 9, (**) 6,48 RA s 30,27 32,08 9, (**) 6,79 RA s 32,09 34,02 9, (**) 7,77 (*) Subsets sanded inside with a small grained metallic (conductive) oxide (**) Single rods (not sanded), 250 g friction bond a part of delivery Helical rods: Aluminium alloy Patch rods are used to repair damaged OPGW (up to 100 % of the outside layer) and are preferably employed in the free span. Patch rods are capable to restore the electrical conductivity and mechanical strength securing thus the full performance of OPGW. The length of the patch rods was determined in such a way, that a damaged place up to 50 cm is covered. In case of larger damaged areas longer special rods are necessary. Installation: he helical rods can be wrapped on by hand in bundles. Tools are not required for installation. The rods have to be installed in such a way that the middle mark of the rods are in the center of the damaged area. Rods of diameters of more than 7 mm must singly be wrapped on. Prior to wrapping on the single rods, the outer layer of OPGW must be cleaned and be covered with friction bond. The friction bond is enclosed on delivery. For installation follow RIBE-Mounting Instruction No. 14. Stand: 06. Februar 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ Patch rods/ 42 / 103

44 B816/1 Tension supports for optical fibre aerial cables and ACSR conductors 1... Boreholes for parallel groove clamp on request. Dimensions are required! RIBE-Order-No. Rated force Mass/ pcs Remarks d F N mm kn kg F /1 20 F / ,9 F / without double eyes, including boreholes for parallel groove clamp (M12, a = 50 mm) F / including boreholes for parallel groove clamp (M12, a = 50 mm) Support: Malleable cast iron, h.d.g. Double eyes: Forged steel, h.d.g. Bolts: Steel, grade 8.8, h.d.g. Tension supports are used to tension optical fibre aerial cables and ACSR conductors. They are typically applied on top of tension towers. Remark: For other executions please inquire. Stand: 26. Juli 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ Tension supports for optical fibre aerial cables and ACSR conductors/ 43 / 103

45 B816/2 Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors 1... Groove A 2... Groove B RIBE-Order-No.. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B /1 A... B... Kb 1 8,00-8,5 1 8,00-8,5 B /1 A... B... Kb 2 8,51-9,0 2 8,51-9,0 B /1 A... B... Kb 3 9,01-9,5 3 9,01-9,5 B /1 A... B... Kb 4 9,51-10,0 4 9,51-10,0 B /1 A... B... Kb 5 10,01-10,5 5 10,01-10,5 B /1 A... B... Kb 6 10,51-11,0 6 10,51-11,0 B /1 A... B... Kb 7 11,01-11,5 7 11,01-11,5 B /1 A... B... Kb 8 11,51-12,0 8 11,51-12,0 B /1 A... B... Kb 9 12,01-12,5 9 12,01-12,5 B /1 A... B... Kb 10 12,51-13, ,51-13,0 B /1 A... B... Kb 11 13,01-13, ,01-13,5 B /1 A... B... Kb 12 13,51-14, ,51-14,0 B /1 A... B... Kb 13 14,01-14, ,01-14,5 B /1 A... B... Kb 14 14,51-15, ,51-15,0 B /1 A... B... Kb 15 15,01-15, ,01-15,5 B /1 A... B... Kb 16 15,51-16, ,51-16,0 B /1 A... B... Kb 17 16,01-16, ,01-16,5 B /1 A... B... Kb 18 16,51-17, ,51-17,0 B /1 A... B... Kb 19 17,01-17, ,01-17,5 B /1 A... B... Kb 20 17,51-18, ,51-18,0 B /1 A... B... Kb 21 18,01-18, ,01-18,5 B /1 A... B... Kb 22 18,51-19, ,51-19,0 B /1 A... B... Kb 23 19,01-19, ,01-19,5 B /1 A... B... Kb 24 19,51-20, ,51-20,0 Stand: 26. Juli 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/ 44 / 103

46 RIBE-Order-No.. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B /1 A... B... Kb 25 20,01-20, ,01-20,5 B /1 A... B... Kb 26 20,51-21, ,51-21,0 B /1 A... B... Kb 27 21,01-21, ,01-21,5 B /1 A... B... Kb 28 21,51 22, ,51 22,0 B /1 A... B... Kb 29 22,01-22, ,01-22,5 Support: Malleable cast iron, h.d.g. Double eyes: Forged steel, h.d.g. Bolts: Steel, grade 8.8, h.d.g. Clamp body: Aluminium, forged Bolts, nuts: M10, stainless steel Tension supports are used to tension and earthing optical fibre aerial cables and ACSR conductors. They are typically applied on top of tension towers. Remarks: Recommended tightening torque of bolts, M10: 46 Nm The exact diameter of grooves A and B are needed when placing an order of tension support with parallel groove clamp acc. to RIBE-No. B Order example: Groove A: 15,8 mm dia. Groove B: 21,2 mm dia. Parallel groove clamp: B /1 A16 B27 Kb For other executions please inquire. Filler bolts: see data-sheet B816/3 Fig.: Mounting example 1... OPGW 2... Tension support with parallel groove clamp 3... Filler bolt Stand: 26. Juli 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/ 45 / 103

47 B816/3 Filler bolts for tension supports with parallel groove clamps Clamping range RIBE-Order-No. d Mass/ pcs Clamping range RIBE-Order-No. d Mass/ pcs mm mm kg mm mm kg 8,00-8,5 B /01 7,9 16,51-17,0 B /18 16,4 8,51-9,0 B /02 8,4 17,01-17,5 B /19 16,9 9,01-9,5 B /03 8,9 17,51-18,0 B /20 17,4 9,51-10,0 B /04 9,4 18,01-18,5 B /21 17,9 10,01-10,5 B /05 9,9 18,51-19,0 B /22 18,4 10,51-11,0 B /06 10,4 19,01-19,5 B /23 18,9 11,01-11,5 B /07 10,9 19,51-20,0 B /24 19,4 11,51-12,0 B /08 11,4 20,01-20,5 B /25 19,9 12,01-12,5 B /09 11,9 20,51-21,0 B /26 20,4 12,51-13,0 B /10 12,4 21,01-21,5 B /27 20,9 13,01-13,5 B /11 12,9 21,51-22,0 B /28 21,4 13,51-14,0 B /12 13,4 22,01-22,5 B /29 21,9 14,01-14,5 B /13 13,9 22,51-23,0 B /30 22,4 14,51-15,0 B /14 14,4 23,01-23,5 B /31 22,9 15,01-15,5 B /15 14,9 23,51-24,0 B /32 23,4 15,51-16,0 B /16 15,4 24,01-24,5 B /33 23,9 16,01-16,5 B /17 15,9 Filler bolt: Aluminium alloy Insert filler bolt in the second groove of the parallel groove clamp in case of earthing of one optical fibre aerial cable on the top of the tower. Remarks: Tension supports with parallel groove clamps: see data-sheet B816/2 and B816/4 For other executions please inquire. Stand: 09. Februar 2009 Pfad: RIBE-Optofit/ Fittings for tension towers/ Filler bolts for tension supports with parallel groove clamps/ 46 / 103

48 B816/4 Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors 1... Groove A 2... Groove B RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B /2 A... B... Kb 1 8,00-8,5 1 8,00-8,5 B /2 A... B... Kb 2 8,51-9,0 2 8,51-9,0 B /2 A... B... Kb 3 9,01-9,5 3 9,01-9,5 B /2 A... B... Kb 4 9,51-10,0 4 9,51-10,0 B /2 A... B... Kb 5 10,01-10,5 5 10,01-10,5 B /2 A... B... Kb 6 10,51-11,0 6 10,51-11,0 B /2 A... B... Kb 7 11,01-11,5 7 11,01-11,5 B /2 A... B... Kb 8 11,51-12,0 8 11,51-12,0 B /2 A... B... Kb 9 12,01-12,5 9 12,01-12,5 B /2 A... B... Kb 10 12,51-13, ,51-13,0 B /2 A... B... Kb 11 13,01-13, ,01-13,5 B /2 A... B... Kb 12 13,51-14, ,51-14,0 B /2 A... B... Kb 13 14,01-14, ,01-14,5 B /2 A... B... Kb 14 14,51-15, ,51-15,0 B /2 A... B... Kb 15 15,01-15, ,01-15,5 B /2 A... B... Kb 16 15,51-16, ,51-16,0 B /2 A... B... Kb 17 16,01-16, ,01-16,5 B /2 A... B... Kb 18 16,51-17, ,51-17,0 B /2 A... B... Kb 19 17,01-17, ,01-17,5 B /2 A... B... Kb 20 17,51-18, ,51-18,0 B /2 A... B... Kb 21 18,01-18, ,01-18,5 B /2 A... B... Kb 22 18,51-19, ,51-19,0 B /2 A... B... Kb 23 19,01-19, ,01-19,5 B /2 A... B... Kb 24 19,51-20, ,51-20,0 Stand: 26. Juli 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/ 47 / 103

49 RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B /2 A... B... Kb 25 20,01-20, ,01-20,5 B /2 A... B... Kb 26 20,51-21, ,51-21,0 B /2 A... B... Kb 27 21,01-21, ,01-21,5 B /2 A... B... Kb 28 21,51 22, ,51 22,0 B /2 A... B... Kb 29 22,01-22, ,01-22,5 Support: Malleable cast iron, h.d.g. Double eyes: Forged steel, h.d.g. Bolts: Steel, grade 8.8, h.d.g. Clamp body: Aluminium, forged Bolts, nuts: M10, stainless steel Tension supports are used to tension and earthing optical fibre aerial cables and ACSR conductors. They are typically applied on top of tension towers. Remarks: Recommended tightening torque of bolts, M10: 46 Nm The exact diameter of grooves A and B are needed when placing an order of tension support with parallel groove clamp acc. to RIBE-No. B Order example: Groove A: 15,8 mm dia. Groove B: 21,2 mm dia. Parallel groove clamp: B /2 A16 B27 Kb For other executions please inquire. Filler bolts: see data-sheet B816/3 Fig.: Mounting example 1... OPGW 2... Tension support with parallel groove clamp 3... Filler bolt Stand: 26. Juli 2007 Pfad: RIBE-Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/ 48 / 103

50 B818 URG-Protection rods RIBE-Order-No. Clamping range Dia. of rods L No. of rods Rod subsets Mass/ pcs mm mm mm Kg URG lis 8,88-9,41 2, ,63 URG lis 9,42-9,99 2, ,65 URG lis 10,00-10,60 2, ,73 URG lis 10,61-11,25 2, ,82 URG lis 11,26 11,93 2, ,91 URG lis 11,94-12,66 2, ,94 URG lis 12,67 13,43 2, ,04 URG lis 13,44-14,24 3, ,50 URG lis 14,25 15,11 3, ,55 URG lis 15,12 16,03 3, ,72 URG lis 16,04 17,00 3, ,90 URG lis 17,01-18,03 3, ,10 URG lis 18,04-19,12 3, ,30 URG lis 19,13 20,28 4, ,03 URG lis 20,29-21,51 4, ,19 URG lis 21,52 22,81 4, ,67 URG lis 22,82-24,19 4, ,18 URG lis 24,20-25,65 4, ,74 URG lis 25,66-27,20 4, ,33 URG lis 27,21 28,84 4, ,98 URG lis 28,85-30,58 4, ,67 Helical rods: Steel, h.d.g. Protection rods are preferably made of steel, h.d.g. and shall protect the self supporting fibre optical aerial cables at tension sets. They are mounted beneath the helical dead end and spread the radial forces on the cable uniformly along the zone of contact. Especially on the cable at the loop-side of the helical dead end radial forces (depending on the tension force) can stress the optical part of the cable inadmissibly. This will cause high damping which results in a reduced data transmission or in the worst case an interruption. The length of the cable guard is determined in such a way that two vibration dampers can be mounted on the rods at the span-side avoiding that the damper clamp is stressing the optical part of the cable. For optical fibre aerial cables with right-hand outer layer, cableguards with left-hand layer are always used in order to avoid a torsion of the cable by the helical dead end with right-hand layer. A torsion of the aerial cable is causing an enlenghtening leading to a destruction of the optical part of the cable. Installation: The helical rods can be wrapped on by hand in bundles. Tools are not required for the assembly. Prior to installation the cable must be cleaned along the overall lenght of protection rods. Fig.: Mounting example Stand: 10. Mai 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ URG-Protection rods/ 49 / 103

51 1... Thimble 2... Protection rods 3... Helical dead end Remarks: These protection rods designs are only suitable for cables with right-hand lay armoring and ADSS cables. If dead ends for left-hand lay cables are required this must be specifically stated when placing the order. Order example: URG s Stand: 10. Mai 2006 Pfad: RIBE-Optofit/ Fittings for tension towers/ URG-Protection rods/ 50 / 103

52 B821 Thimbles for helical dead ends for OPGW and ADSS RIBE-Order-No. Suitable for helical dead ends with clamping range r d Rated force Mass/ pcs mm mm mm kn kg F 2684/3 6,8-15, ,85 F 2685/3 15,1-22, ,90 F 2686/2 21,7-28, ,44 F 3246/2 28,5-39, ,90 F /2 36,1-52, ,50 Thimbles: Malleable cast iron, h.d.g. The thimbles together with helical dead ends serve for the tensioning of self supporting optical fibre aerial cables. Remark: Helical dead ends: see data-sheet B810 ff. Stand: 03. Juli 2007 Pfad: RIBE-Optofit/ Thimbles/ Thimbles for helical dead ends for OPGW and ADSS/ 51 / 103

53 B822 Thimbles for helical dead ends for OPGW and ADSS RIBE-Order-No. Suitable for helical dead ends with clamping range a b Mass/ pcs mm mm mm kg E ,74-11,55 (Loop diameter of helical rods: 50 mm) ,08 B ,00-7,5 (Loop diameter of helical rods: 25 mm) ,05 B ,00-12,5 (Loop diameter of helical rods: 40 mm) ,10 F ,0-19,3 (Loop diameter of helical rods: 50 mm) ,05 F ,9-32,5 (Loop diameter of helical rods: 50 mm) ,06 F ,0-19,3 (Loop diameter of helical rods: 64 mm) ,10 Thimbles: Steel, h.d.g. The thimbles together with helical dead ends serve for the tensioning of self supporting optical fibre aerial cables. They are used in cases of low tension forces (ADSS cables). Remark: Helical dead ends: see data-sheet B810 ff. Stand: 18. August 2006 Pfad: RIBE-Optofit/ Thimbles/ Thimbles for helical dead ends for OPGW and ADSS/ 52 / 103

54 B823 Ring type thimbles for suspension rods for ADSS RIBE-Order-No. Suitable for suspension rods a b c Mass/ pcs mm mm mm kg E 5119 TG - LG - suspension rods (see data-sheet B805/5) ,04 F TG - UTA - suspension rods (see data-sheet B805/2 and B814/2) ,10 Thimbles: Steel, h.d.g. These thimbles serve as movable suspension of ADSS cables together with suspension rods. The loop of the suspension rods is stabilized and protected against abrasion with ring type thimbles. Stand: 18. August 2006 Pfad: RIBE-Optofit/ Thimbles/ Ring type thimbles for suspension rods for ADSS/ 53 / 103

55 B831 Earthing connections (complete) for loops 1... Parallel groove clamp 2... Shunt 3... Earthing connection 4... OPGW Earthing connection Diameter of OPGW Shunt Parallel groove clamp RIBE-Order-No. Conductor Length RIBE-No. RIBE-No. mm F /2 22,6-22,7 F /2 F /1 23,1 F /1 F /5 23,8 F /5 F /7 25,1 Al 120 mm² - 14,0 mmø 1000 mm F /1 F /7 F /3 26,1 F /3 F /6 28,5 F /6 F /4 29,9 F /4 F /1 12,1 Al/St 150/25 mm² - 17,1 mmø 1000 mm F /1 F /1 F /2 12,5-12,6 F /2 F /1 18,4 Al/St 265/35 mm² - 22,4 mmø 1000 mm F /1 F ) Parallel groove clamp Clamp body: Casted Aluminium Bolts, nuts: h.d.g., alternatively stainless steel 2) Shunt ACSR- or Al-conductor Bolts, nuts: M12, h.d.g., alternatively stainless steel The earthing connections consist of one parallel groove clamp and one shunt. They are used to get a defined earthing. Remarks: For other executions please inquire. Parallel groove clamps: see data-sheet B832/1, B832/2 and B832/3 Shunts: see data-sheet B833/1 and B833/2 Order example: F /4 (consisting of shunt F /1 and parallel groove clamp F /4) Stand: 10. August 2006 Pfad: RIBE-Optofit/ Earthing material/ Earthing connections (complete) for loops/ 54 / 103

56 B832/1 Parallel groove clamps (with 2 bolts) 1... OPGW (groove A) 2... Shunt (groove B) 3... Bolt M10 RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B /A... B... Kb 1 8,0-8,5 1 8,0-8,5 B /A... B... Kb 2 8,51-9,0 2 8,51-9,0 B /A... B... Kb 3 9,01-9,5 3 9,01-9,5 B /A... B... Kb 4 9,51-10,0 4 9,51-10,0 B /A... B... Kb 5 10,01-10,5 5 10,01-10,5 B /A... B... Kb 6 10,51-11,0 6 10,51-11,0 0,26 B /A... B... Kb 7 11,01-11,5 7 11,01-11,5 B /A... B... Kb 8 11,51-12,0 8 11,51-12,0 B /A... B... Kb 9 12,01-12,5 9 12,01-12,5 B /A... B... Kb 10 12,51-13, ,51-13,0 B /A... B... Kb 11 13,01-13, ,01-13,5 B /A... B... Kb 12 13,51-14, ,51-14,0 Clamp body: Aluminium, forged Bolts, nuts: Stainless steel See data-sheet B831 Remarks: Recommended tightening torque of bolts, M10: 46 Nm The exact diameter of grooves A and B are needed when placing an order of parallel groove clamp acc. to RIBE-No. B Order example: Groove A: 10,8 mm dia. Groove B: 12,5 mm dia. Parallel groove clamp: B / A6 B9 Kb For other executions please inquire. Shunts: see data-sheet B833/1 and B833/2 Stand: 18. Dezember 2009 Pfad: RIBE-Optofit/ Earthing material/ Parallel groove clamps (with 2 bolts)/ 55 / 103

57 B832/2 Parallel groove clamps (with 3 bolts) 1... Groove A 2... Groove B 3... Bolt F /3 2) RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B /A... B... Kb 1) 1 8,00-8,5 1 8,00-8,5 B /A... B... Kb 1) 2 8,51-9,0 2 8,51-9,0 B /A... B... Kb 1) 3 9,01-9,5 3 9,01-9,5 B /A... B... Kb 1) 4 9,51-10,0 4 9,51-10,0 B /A... B... Kb 1) 5 10,01-10,5 5 10,01-10,5 B /A... B... Kb 1) 6 10,51-11,0 6 10,51-11,0 B /A... B... Kb 1) 7 11,01-11,5 7 11,01-11,5 B /A... B... Kb 1) 8 11,51-12,0 8 11,51-12,0 B /A... B... Kb 1) 9 12,01-12,5 9 12,01-12,5 B /A... B... Kb 1) 10 12,51-13, ,51-13,0 B /A... B... Kb 1) 11 13,01-13, ,01-13,5 B /A... B... Kb 1) 12 13,51-14, ,51-14,0 B /A... B... Kb 1) 13 14,01-14, ,01-14,5 B /A... B... Kb 1) 14 14,51-15, ,51-15,0 0,58 B /A... B... Kb 1) 15 15,01-15, ,01-15,5 B /A... B... Kb 1) 16 15,51-16, ,51-16,0 B /A... B... Kb 1) 17 16,01-16, ,01-16,5 B /A... B... Kb 1) 18 16,51-17, ,51-17,0 B /A... B... Kb 1) 19 17,01-17, ,01-17,5 B /A... B... Kb 1) 20 17,51-18, ,51-18,0 B /A... B... Kb 1) 21 18,01-18, ,01-18,5 B /A... B... Kb 1) 22 18,51-19, ,51-19,0 B /A... B... Kb 1) 23 19,01-19, ,01-19,5 B /A... B... Kb 1) 24 19,51-20, ,51-20,0 B /A... B... Kb 1) 25 20,01-20, ,01-20,5 B /A... B... Kb 1) 26 20,51-21, ,51-21,0 B /A... B... Kb 1) 27 21,01-21, ,01-21,5 B /A... B... Kb 1) 28 21,51-22, ,51-22,0 B /A... B... Kb 1) 29 22,01-22, ,01-22,5 B /A... B... Kb 1) 30 13,30-13, ,30-13,8 F /2 2) 22,6-22,7 F /1 2) 23,1 F /5 2) 23,8 F /7 2) 25,1 mm² - 14,0 26,1 0,8 Al 120 mmø F /8 2) 27,2 Stand: 18. Dezember 2009 Pfad: RIBE-Optofit/ Earthing material/ Parallel groove clamps (with 3 bolts)/ 56 / 103

58 RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg F /6 2) 28,5 F /4 2) 29,9 Clamp body: 1) Aluminium, forged 2) Casted Aluminium Bolts, nuts: 1) M10, stainless steel 2) M12, h.d.g., alternatively stainless steel See data-sheet B831 Remarks: 1) Recommended tightening torque of bolts, M10: 46 Nm 2) Recommended tightening torque of bolts, M12: 60 Nm The exact diameter of grooves A and B are needed when placing an order of parallel groove clamp acc. to RIBE-No. B Order example: Groove A: 15,8 mm dia. Groove B: 21,2 mm dia. Parallel groove clamp: B / A16 B27 Kb For other executions please inquire. Shunts: see data-sheet B833/1 and B833/2 Stand: 18. Dezember 2009 Pfad: RIBE-Optofit/ Earthing material/ Parallel groove clamps (with 3 bolts)/ 57 / 103

59 B832/3 Parallel groove clamps (special design) 1... Shunt (Al/St) 2... OPGW 3... Bolt M12 RIBE-Order-No. Diameter of OPGW Mass/ pcs Shunt mm kg F /4 16,0-16,1 F /6 16,3 0,6 Al/St 95/55 mm² - 16,0 mmø F /1 16,4-16,6 F /7 18,2 F /2 18,9-19,0 F /1 19,3-19,4 0,7 Al/St 185/30 mm² - 19,0 mmø F /3 19,5-19,6 F /3 14,5 F /2 18,0 0,9 F /1 18,5 F ,4 (Al/St 210/36 mm² - 20,5 mmø) F ,0 0,7 Al/St 210/35 mm² - 20,3 mmø F ,2 F ,4-22,5 F ,7 F /2 25,1 1,13 F /1 30,3 1,13 F ,9 F ,0 0,9 F ,2-15,6 F ,6 F ,0 F ,4-18,7 F ,4 Al/St 265/35 mm² - 22,4 mmø F /2 21,4 F ,7-21,8 0,7 F /1 22,1-22,4 F /3 23,3-23,4 F ,7-22,9 F ,1 0,7 F ,1-25,2 F /1 25,8 Al/St 265/35 mm² - 22,4 mmø F /2 27,3 Al/St 265/35 mm² - 22,4 mmø F /3 28,0 0,7 Al/St 265/35 mm² - 22,4 mmø F /4 25,2 Al/St 340/30 mm² - 25,0 mmø F /5 26,8 Al/St 265/35 mm² - 22,4 mmø F /6 24,6 Al/St xxx/xx mm² - 21,7 mmø F /4 25,2 0,7 Al/St 340/30 mm² - 25,0 mmø Clamp body: Aluminium, forged Bolts, nuts: h.d.g., alternatively stainless steel See data-sheet B831 Stand: 07. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Parallel groove clamps (special design)/ 58 / 103

60 Remarks: Recommended tightening torque of bolts, M12: 60 Nm For other executions please inquire. Shunts: see data-sheet B833/1 and B833/2 Stand: 07. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Parallel groove clamps (special design)/ 59 / 103

61 B832/4 Earthing profil for fixing of OPGW with helical fittings 1... Bolt M10/ 46 Nm/ W.a.f. 17 RIBE-Order-No. Clamping range Helical rods Mass/ pcs D 1 RIBE-No. L D 2 No. of wires H mm mm mm mm kg B /1 8,80-10,09 TW , ,5 0,17 B /2 10,10-11,49 TW , ,5 0,17 B /3 11,50-13,10 TW , ,0 0,17 B /4 13,11-14,81 TW , ,5 0,18 B /5 14,82-16,62 TW , ,0 0,18 B /6 16,63-18,53 TW , ,0 0,19 B /7 18,54-20,54 TW , ,0 0,20 B /8 20,55-22,60 TW , ,5 0,20 Helical rods: Aluminium-clad steel Clamp body: Aluminium Threaded bolt, nut: Stainless steel A2-80 Washer: Stainless steel A2 The earthing profil consists of a clamp body and a set of helical rods, which fix the OPGW on the clamp body. The earthing profil is fixed on the tower by means of a threaded bolt. The earthing profil is used to get a defined earthing and is safe from short current. Remarks: The exact diameter of cable is needed when placing an order of earthing profil acc. to RIBE-No. B Order example: Cable: 15,8 mm dia. Earthing profil: B / A5 For other executions please inquire. Stand: 15. Mai 2006 Pfad: RIBE-Optofit/ Earthing material/ Earthing profil for fixing of OPGW with helical fittings/ 60 / 103

62 B833/1 Shunts with ACSR-conductors RIBE-Order-No. Conductor Dimensions I K L a b c α mm mm mm mm ka F / , F /2 Al/St 150/25 mm² - 17,1 mmø , ,8 F / , F / ,7 42, F /2 Al/St 185/30 mm² - 19,0 mm ,7 42, ,5 F / ,7 42, F /2 (Al/St 210/36 mm² - 20,5 mmø) ,0 46, F /3 (Al/St 210/36 mm² - 20,5 mm ) ,0 46, F /5 Al/St 210/35 mm² - 20,3 mm ,0 46, F / ,0 46, ,2 F / ,0 46, F / ,0 46, F / ,0 46, F /1 Al/St 265/35 mm² - 22,4 mm ,5 47, ,5 F / ,5 47, Cable lug: Aluminium alloy Conductor: ACSR Bolts, nuts: M12, h.d.g., alternatively stainless steel See data-sheet B831 Installation: Recommended tightening torque of Bolts M12: 80 Nm Remarks: The short current values I K are valid for a shunt with a current density of 100 A/mm² (in the Al-Part) and heat the shunts up from the starting temperature? = 20 Χ το τηε ενδ τεµπερατυρε? = 160 Χ. For other executions please inquire. Stand: 10. August 2006 Pfad: RIBE-Optofit/ Earthing material/ Shunts with ACSR-conductors/ 61 / 103

63 B833/2 Shunts with Al-conductors Fig. 1 Fig. 2 Fig. RIBE-Order-No. Conductor Dimensions I K L a b c α α 1 mm mm mm mm ka 1 F / F / F /3 Al 95 mm² - 12,5 mm ,1 1 F / F / F / F Al 120 mm² - 14,0 mm ,4 1 F / F / F / F / F / F /6 Al 120 mm² - 14,0 mm ,4 2 F / F / F / F / F / Stand: 04. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Shunts with Al-conductors/ 62 / 103

64 Fig. RIBE-Order-No. Conductor Dimensions I K L a b c α α 1 mm mm mm mm ka 1 F / Cable lug: Aluminium alloy Conductor: Al Bolts, nuts: M12, h.d.g., alternatively stainless steel See data-sheet B831 Installation: Recommended tightening torque of Bolts M12: 80 Nm Remarks: The short current values I K are valid for a shunt with a current density of 100 A/mm² and heat the shunts up from the starting temperature? = 20 C to the end temperature? = 160 C. For other executions please inquire. Stand: 04. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Shunts with Al-conductors/ 63 / 103

65 B833/4 Earth bonds for OPGW with helical attachment, aluminium earthing conductor and cable lug 1... Contact piece 2... Attachment rods Earth bond with helical attachment B /Ax Ly Exe. x D 1 Helical rods H Earthing conductor RIBE-Order-No. No. of rods D 2 L 1 Description D 3 mm mm mm mm mm 1 8,80-10,09 TW , ,0 2 10,10-11,49 TW , ,0 3 11,50-13,10 TW , ,5 4 13,11-14,81 TW , ,0 Al 95 mm² 12,5 5 14,82-16,62 TW , ,5 I k = 9,1 ka 6 16,63-18,53 TW , ,5 7 18,54-20,54 TW , ,5 8 20,55-22,60 TW , ,0 Length of shunt L Exe. y L 3 / mm Earth bond with helical attachment B /Ax Ly Exe. x D 1 Helical rods H Earthing conductor RIBE-No. No. of rods D 2 L 1 Description D 3 mm mm mm mm mm 1 8,80-10,09 TW , ,0 2 10,10-11,49 TW , ,0 3 11,50-13,10 TW , ,5 4 13,11-14,81 TW , ,0 Al 120 mm² 14,0 5 14,82-16,62 TW , ,5 I K = 11,4 ka 6 16,63-18,53 TW , ,5 7 18,54-20,54 TW , ,5 8 20,55-22,60 TW , ,0 Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Earthing material/ Earth bonds for OPGW with helical attachment, aluminium earthing conductor and cable lug/ 64 / 103

66 Contact piece: Aluminium alloy Cable lug: Aluminium alloy Earthing conductor: Al Bolt, nut: M16, h.d.g., alternatively stainless steel Helical attachment rods: Aluminium-clad steel Installation: Recommended tightening torque of Bolt M16: 190 Nm Remarks: Short-circuit current ratings are based on a short-circuit current I K for 1 s with a current density of 100 A/mm² (initial temperature? = 20 C, final temperature? = 160 C). Order example: OPGW-Diameter: 13,5 mm Conductor: Al 95 mm² - 12,5 mmø Length of conductor: 2000 mm RIBE-Order-No.: B /A4 L2 For other sizes please inquire. Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Earthing material/ Earth bonds for OPGW with helical attachment, aluminium earthing conductor and cable lug/ 65 / 103

67 B834/1 Shunts with flexible Cu-conductors for armour grip suspensions (cable lug on tower side with 2 holes) Fig.: Mounting example 1... Cable lug A 2... Cable lug B Cable lug, flexible shunt: Electrolytic copper, tinned To thermically relieve the hinges of the suspension clamps in case of a short-circuit, we recommend shunts. Dependent on short-circuit value one or two shunts are installed. They connect the two halves of the clamp to the tower. Remarks: Bolt sets for fixing the shunts to the tower are not included. If required, they have to be ordered separately (e.g. bolt M 12x55 grade 8.8 including nut and 2 washers; bolts and nuts hot dipped galvanized; stainless steel washers). On request shunts can be delivered with shrinkdown plastic tubing (order example: 60500a). The short-circuit values I th are valid for a shunt with a current density of 150 A/mm² and heat the shunts up from the starting temperature? = 20 C to the end temperature? = 160 C. Amor grip suspensions: see data-sheet B801/2 and B801/4 For other executions please inquire. RIBE-Order-No.. For armour grip suspension Flex. shunt Mass/ a b c L A Dia. I th pcs mm mm mm mm mm² mm ka kg LTA /7 LTA / LTA / , ,0 5,5 0,4 LTA /14 LTA /15 LTA /16 LTA /6 LTA /7 Stand: 04. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Shunts with flexible Cu-conductors for armour grip suspensions (cable lug on tower side with 2 holes)/ 66 / 103

68 RIBE-Order-No.. For armour grip suspension Flex. shunt Mass/ a b c L A Dia. I th pcs mm mm mm mm mm² mm ka kg LTA / , ,5 7,5 0,52 LTA /9 LTA /10 LTA /5 LTA /6 LTA /7 LTA /8 LTA /9 LTA /10 LTA /11 LTA /12 LTA /5 LTA /6 LTA / LTA / , ,5 7,5 0,54 LTA /7 LTA /8 LTA /9 LTA /10 LTA /11 LTA /12 LTA /6 LTA /7 LTA /8 LTA /9 LTA /10 LTA /5 LTA /6 LTA /7 LTA /8 LTA /9 LTA /10 LTA / LTA / oder LTA /13 30 oder ,0 10,7 0, LTA /14 50 LTA /15 LTA /16 LTA /17 LTA /18 LTA /11 LTA /12 LTA /13 LTA /14 LTA /15 Stand: 04. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Shunts with flexible Cu-conductors for armour grip suspensions (cable lug on tower side with 2 holes)/ 67 / 103

69 B834/2 Shunts with Al-conductors for armour grip suspensions (cable lug on tower side with 1 hole) Fig.: Mounting example 1... Cable lug A 2... Cable lug B Cable lug, flexible shunt: Electrolytic copper, tinned To thermically relieve the hinges of the suspension clamps in case of a short-circuit, we recommend shunts. Dependent on short-circuit value one or two shunts are installed. They connect the two halves of the clamp to the tower. Remarks: Bolt sets for fixing the shunts to the tower are not included. If required, they have to be ordered separately (e.g. bolt M 16x55 grade 8.8 including nut and 2 washers; bolts and nuts hot dipped galvanized; stainless steel washers). On request shunts can be delivered with shrinkdown plastic tubing (order example: F /1a). The short-circuit values I th are valid for a shunt with a current density of 150 A/mm² and heat the shunts up from the starting temperature? = 20 C to the end temperature? = 160 C. Amor grip suspensions: see data-sheet B801/2 and B801/4 For other executions please inquire. RIBE-Order-No.. For armour grip suspension Flex. shunt Mass/ a c L A Dia. I th pcs mm mm mm mm² mm ka kg LTA /7 LTA /8 F /1 LTA / , ,0 5,5 0,4 LTA /14 LTA /15 LTA /16 LTA /6 LTA /7 Stand: 04. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Shunts with Al-conductors for armour grip suspensions (cable lug on tower side with 1 hole)/ 68 / 103

70 RIBE-Order-No.. For armour grip suspension Flex. shunt Mass/ a c L A Dia. I th pcs mm mm mm mm² mm ka kg F /2 LTA /8 25 8, ,5 7,5 0,52 LTA /9 LTA /10 LTA /5 LTA /6 LTA /7 LTA /8 LTA /9 LTA /10 LTA /11 LTA /12 LTA /5 LTA /6 LTA /7 F /3 LTA / , ,5 7,5 0,54 LTA /7 LTA /8 LTA /9 LTA /10 LTA /11 LTA /12 LTA /6 LTA /7 LTA /8 LTA /9 LTA /10 LTA /5 LTA /6 LTA /7 LTA /8 LTA /9 LTA /10 LTA /11 LTA /12 F /4 LTA / ,0 10,7 0,78 LTA /14 LTA /15 LTA /16 LTA /17 LTA /18 LTA /11 LTA /12 LTA /13 LTA /14 LTA /15 Stand: 04. Mai 2007 Pfad: RIBE-Optofit/ Earthing material/ Shunts with Al-conductors for armour grip suspensions (cable lug on tower side with 1 hole)/ 69 / 103

71 B841/1 Fixing clamps (height = 200 mm) for optical aerial cables at lattice towers 1... Optical fibre aerial cable 2... Optical fibre aerial cable or filler bolt 3... Tower Clamping range RIBE-Order-No. Mass/ RIBE-No. for Filler bolt Clamping range RIBE-Order-No. Mass/ RIBE-No. for Filler bolt pcs pcs mm kg mm kg 9,01-9,5 F /32 F /32 19,51-20,0 F /20 F /20 9,51-10,0 F /33 F /33 20,01-20,5 F /21 F /21 10,01-10,5 F /01 F /01 20,51-21,0 F /22 F /22 10,51-11,0 F /02 F /02 21,01-21,5 F /23 F /23 11,01-11,5 F /03 F /03 21,51-22,0 F /24 0,8 F /24 11,51-12,0 F /04 F /04 22,01-22,5 F /25 F /25 12,01-12,5 F /05 F /05 22,51-23,0 F /26 F /26 12,51-13,0 F /06 F /06 23,01-23,5 F /27 F /27 13,01-13,5 F /07 0,8 F /07 23,51-24,0 F /28 F /28 13,51-14,0 F /08 F /08 24,01-24,5 F /29 F /29 14,01-14,5 F /09 F /09 24,51-25,0 F /30 F /30 Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 200 mm) for optical aerial cables at lattice towers/ 70 / 103

72 Clamping range RIBE-Order-No. Mass/ RIBE-No. for Filler bolt Clamping range RIBE-Order-No. Mass/ RIBE-No. for Filler bolt pcs pcs mm kg mm kg 14,51-15,0 F /10 F /10 25,01-25,5 F /31 F /31 15,01-15,5 F /11 F /11 25,51-26,0 F /01 F /34 15,51-16,0 F /12 F /12 26,01-26,5 F /02 F /35 16,01-16,5 F /13 F /13 26,51-27,0 F /03 F /36 16,51-17,0 F /14 F /14 27,01-27,5 F /04 F /37 17,01-17,5 F /15 F /15 27,51-28,0 F /05 F /38 17,51-18,0 F /16 F /16 28,01-28,5 F /06 0,8 F /39 18,01-18,5 F /17 F /17 28,51-29,0 F /07 F /40 18,51-19,0 F /18 F /18 29,01-29,5 F /08 F /41 19,01-19,5 F /19 F /19 29,51-30,0 F /09 F /42 Clamp: Aluminium alloy, forged U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box. Insert filler bolt acc. to drawing No. F /index in second groove if only one cable is led down the tower. By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible. Installation: Recommended tightening torque for clamp: 30 Nm Recommended tightening torque for U-bracket: 15 Nm Remarks: Filler bolts: see data-sheet B845 For other executions please inquire. Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 200 mm) for optical aerial cables at lattice towers/ 71 / 103

73 B841/2 Fixing clamps (height = 250 mm) for optical fibre aerial cables at lattice towers 1... Optical fibre aerial cable 2... Optical fibre aerial cable or filler bolt 3... Tower Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt pcs pcs mm kg mm kg 9,01-9,5 F /32 F /32 17,51-18,0 F /16 F /16 9,51-10,0 F /33 F /33 18,01-18,5 F /17 F /17 10,01-10,5 F /01 F /01 18,51-19,0 F /18 F /18 10,51-11,0 F /02 F /02 19,01-19,5 F /19 F /19 11,01-11,5 F /03 F /03 19,51-20,0 F /20 F /20 11,51-12,0 F /04 F /04 20,01-20,5 F /21 F /21 12,01-12,5 F /05 F /05 20,51-21,0 F /22 F /22 12,51-13,0 F /06 F /06 21,01-21,5 F /23 F /23 13,01-13,5 F /07 0,8 F /07 21,51-22,0 F /24 0,8 F /24 13,51-14,0 F /08 F /08 22,01-22,5 F /25 F /25 14,01-14,5 F /09 F /09 22,51-23,0 F /26 F /26 Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 250 mm) for optical fibre aerial cables at lattice towers/ 72 / 103

74 Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt pcs pcs mm kg mm kg 14,51-15,0 F /10 F /10 23,01-23,5 F /27 F /27 15,01-15,5 F /11 F /11 23,51-24,0 F /28 F /28 15,51-16,0 F /12 F /12 24,01-24,5 F /29 F /29 16,01-16,5 F /13 F /13 24,51-25,0 F /30 F /30 16,51-17,0 F /14 F /14 25,01-25,5 F /31 F /31 17,01-17,5 F /15 F /15 Clamp: Aluminium alloy, forged U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box. Insert filler bolt acc. to drawing No. F /index in second groove if only one cable is led down the tower. By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible. Installation: Recommended tightening torque for clamp: 30 Nm Recommended tightening torque for U-bracket: 15 Nm Remarks: Filler bolts: see data-sheet B845 For other executions please inquire. Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 250 mm) for optical fibre aerial cables at lattice towers/ 73 / 103

75 B841/3 Fixing clamps for optical fibre aerial cables at towers with steel rod, concrete or wood 1... Optical fibre aerial cable 2... Optical fibre aerial cable or filler bolt 3... Fixing clip 4... Steel tape 5... Fixing clip for steel tape attachment 6... Tower Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt pcs pcs mm kg mm kg 9,01-9,5 B /32 F /32 19,51-20,0 B /20 F /20 9,51-10,0 B /33 F /33 20,01-20,5 B /21 F /21 10,01-10,5 B /01 F /01 20,51-21,0 B /22 F /22 10,51-11,0 B /02 F /02 21,01-21,5 B /23 F /23 11,01-11,5 B /03 F /03 21,51-22,0 B /24 F /24 11,51-12,0 B /04 F /04 22,01-22,5 B /25 F /25 12,01-12,5 B /05 F /05 22,51-23,0 B /26 F /26 12,51-13,0 B /06 F /06 23,01-23,5 B /27 F /27 13,01-13,5 B /07 F /07 23,51-24,0 B /28 F /28 13,51-14,0 B /08 0,46 F /08 24,01-24,5 B /29 0,46 F /29 14,01-14,5 B /09 F /09 24,51-25,0 B /30 F /30 14,51-15,0 B /10 F /10 25,01-25,5 B /31 F /31 15,01-15,5 B /11 F /11 25,51-26,0 B /34 F /34 15,51-16,0 B /12 F /12 26,01-26,5 B /35 F /35 16,01-16,5 B /13 F /13 26,51-27,0 B /36 F /36 16,51-17,0 B /14 F /14 27,01-27,5 B /37 F /37 17,01-17,5 B /15 F /15 27,51-28,0 B /38 F /38 17,51-18,0 B /16 F /16 28,01-28,5 B /39 F /39 18,01-18,5 B /17 F /17 28,51-29,0 B /40 F /40 18,51-19,0 B /18 F /18 29,01-29,5 B /41 F /41 Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps for optical fibre aerial cables at towers with steel rod, concrete or wood / 74 / 103

76 Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt Clamping range RIBE-Order-No. Mass/ RIBE-No. for Fillerbolt pcs pcs mm kg mm kg 19,01-19,5 B /19 F /19 29,51-30,0 B /42 F /42 Part name RIBE-Order-No. Remark Steel tape B T7 to be ordered separately Fixing clip B T8 to be ordered separately Clamp: Aluminium alloy, forged U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 Fixing clip: Steel, h.d.g. Steel tape: Stainless steel Fixing clip: Stainless steel These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the consisting of steel, concrete, or wood to the joint box. Insert filler bolt acc. to drawing No. F /index in second groove if only one cable is led down the tower. Installation: Recommended tightening torque for clamp: 30 Nm Remarks: Filler bolts: see data-sheet B845 For other executions please inquire. Stand: 31. Juli 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps for optical fibre aerial cables at towers with steel rod, concrete or wood / 75 / 103

77 B841/5 Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers 1... Groove A 2... Groove B 3... Tower RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B / 1 9,00-9,5 1 9,00-9,5 B / 2 9,51-10,0 2 9,51-10,0 B / 3 10,01-10,5 3 10,01-10,5 B / 4 10,51-11,0 4 10,51-11,0 B / 5 11,01-11,5 5 11,01-11,5 B / 6 11,51-12,0 6 11,51-12,0 B / 7 12,01-12,5 7 12,01-12,5 B / 8 12,51-13,0 8 12,51-13,0 B / 9 13,01-13,5 9 13,01-13,5 B / 10 13,51-14, ,51-14,0 B / 11 14,01-14, ,01-14,5 B / 12 14,51-15, ,51-15,0 Stand: 20. März 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/ 76 / 103

78 RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. mm kg B / 13 15,01-15, ,01-15,5 B / 14 15,51-16, ,51-16,0 B / 15 16,01-16, ,01-16,5 B / 16 16,51-17, ,51-17,0 B / 17 17,01-17, ,01-17,5 B / 18 17,51-18, ,51-18,0 B / 19 18,01-18, ,01-18,5 B / 20 18,51-19, ,51-19,0 B / 21 19,01-19, ,01-19,5 0,8 B / 22 19,51-20, ,51-20,0 B / 23 20,01-20, ,01-20,5 B / 24 20,51-21, ,51-21,0 B / 25 21,01-21, ,01-21,5 B / 26 21,51-22, ,51-22,0 B / 27 22,01-22, ,01-22,5 B / 28 22,51-23, ,51-23,0 B / 29 23,01-23, ,01-23,5 B / 30 23,51-24, ,51-24,0 B / 31 24,01-24, ,01-24,5 B / 32 24,51-25, ,51-25,0 B / 33 25,01-25, ,01-25,5 B / 34 25,51-26, ,51-26,0 B / 35 26,01-26, ,01-26,5 B / 36 26,51-27, ,51-27,0 B / 37 27,01-27, ,01-27,5 B / 38 27,51-28, ,51-28,0 B / 39 28,01-28, ,01-28,5 B / 40 28,51-29, ,51-29,0 B / 41 29,01-29, ,01-29,5 B / 42 29,51-30, ,51-30,0 Clamp: Aluminium alloy, forged U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box. By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible. Installation: Recommended tightening torque for clamp: 30 Nm Recommended tightening torque for U-bracket: 15 Nm Remarks: The exact diameter of grooves A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B Order example: Groove A: 15,8 mm dia. Groove B: 21,2 mm dia. Fixing clamp: B / A14 B25 Stand: 20. März 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/ 77 / 103

79 B841/7 Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers 1... Groove A 2... Groove B 3... Tower RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. Mm κγ B / 1 9,00-9,5 1 9,00-9,5 B / 2 9,51-10,0 2 9,51-10,0 B / 3 10,01-10,5 3 10,01-10,5 B / 4 10,51-11,0 4 10,51-11,0 B / 5 11,01-11,5 5 11,01-11,5 B / 6 11,51-12,0 6 11,51-12,0 B / 7 12,01-12,5 7 12,01-12,5 B / 8 12,51-13,0 8 12,51-13,0 B / 9 13,01-13,5 9 13,01-13,5 B / 10 13,51-14, ,51-14,0 B / 11 14,01-14, ,01-14,5 B / 12 14,51-15, ,51-15,0 Stand: 20. März 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/ 78 / 103

80 RIBE-Order-No. Clamping range of groove A Clamping range of groove B Mass/ pcs Exe. mm Exe. Mm κγ B / 13 15,01-15, ,01-15,5 B / 14 15,51-16, ,51-16,0 B / 15 16,01-16, ,01-16,5 B / 16 16,51-17, ,51-17,0 B / 17 17,01-17, ,01-17,5 B / 18 17,51-18, ,51-18,0 B / 19 18,01-18, ,01-18,5 B / 20 18,51-19, ,51-19,0 B / 21 19,01-19, ,01-19,5 0,8 B / 22 19,51-20, ,51-20,0 B / 23 20,01-20, ,01-20,5 B / 24 20,51-21, ,51-21,0 B / 25 21,01-21, ,01-21,5 B / 26 21,51-22, ,51-22,0 B / 27 22,01-22, ,01-22,5 B / 28 22,51-23, ,51-23,0 B / 29 23,01-23, ,01-23,5 B / 30 23,51-24, ,51-24,0 B / 31 24,01-24, ,01-24,5 B / 32 24,51-25, ,51-25,0 B / 33 25,01-25, ,01-25,5 B / 34 25,51-26, ,51-26,0 B / 35 26,01-26, ,01-26,5 B / 36 26,51-27, ,51-27,0 B / 37 27,01-27, ,01-27,5 B / 38 27,51-28, ,51-28,0 B / 39 28,01-28, ,01-28,5 B / 40 28,51-29, ,51-29,0 B / 41 29,01-29, ,01-29,5 B / 42 29,51-30, ,51-30,0 Clamp: Aluminium alloy, forged U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box. By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible. Installation: Recommended tightening torque for clamp: 30 Nm Recommended tightening torque for U-bracket: 15 Nm Remarks: The exact diameter of grooves A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B Order example: Groove A: 15,8 mm dia. Groove B: 21,2 mm dia. Fixing clamp: B / A14 B25 Stand: 20. März 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/ 79 / 103

81 B841/8 Fixing clamps for optical fibre aerial cables at lattice towers RIBE-Order-No. Clamping range ØD A Mass/ pcs Fig. 1 Fig. 2 mm mm kg B /1 B /1 8,00-10,00 32 B /2 B /2 10,01-12,50 35 B /3 B /3 12,51-15, ,5 B /4 B /4 15,51-19,50 42 B /5 B /5 19,51-25,00 47 U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 Clip: Stainless steel These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box. Insert filler bolt acc. to drawing No. F /index in second groove if only one cable is led down the tower. By a 90 turn of the U-bracket a turned fixing is possible. Installation: Recommended tightening torque for U-bracket: 15 Nm Remarks: Filler bolts: see data-sheet B845 For other executions please inquire. Stand: 27. Februar 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps for optical fibre aerial cables at lattice towers/ 80 / 103

82 B844/1 Fixing clamps with helical fittings 1... RIBE-Order-No. B /Ax Bx 2... RIBE-Order-No. B /Ax Bx 3... RIBE-Order-No. B /Ax Bx 4... Cable A 5... Cable B 6... M A = 23 Nm/ W.a.f W.a.f M A = 15 Nm/ W.a.f. 13 RIBE-Order-No. B /Ax Bx or B /Ax Bx or B /Ax Bx Cable A Cable B Helical rods Mass/ Exe. Clamping range Exe. Clamping range RIBE-No. L Dia. No. of wires pcs mm mm mm mm kg 9 7,00-7,90 9 7,00-7,90 TW , ,91-8, ,91-8,79 TW ,59 1 8,80-10,09 1 8,80-10,09 TW , ,10-11, ,10-11,49 TW , ,50-13, ,50-13,10 TW ,90 3 0,4 4 13,11-14, ,11-14,81 TW , ,82-16, ,82-16,62 TW , ,63-18, ,63-18,53 TW , ,54-20, ,54-20,54 TW , ,55-22, ,55-22,55 TW , ,56-24, ,56-24,50 TW ,25 Helical rods: Aluminium-clad steel U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box. By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible. Remarks: The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B or B or B Order example: Cable A: 15,8 mm dia. Cable B: 21,2 mm dia. Fixing clamp: B / A5 B8 or B / A5 B8 or B / A5 B8 For other executions please inquire. Stand: 13. März 2007 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings/ 81 / 103

83 B844/2 Fixing clamps with helical fittings for optical fibre aerial cables at rounded towers with steel ods, concrete or wood 1... Cable A 2... Cable B 3... Fixing clip 4... Steel tape 5... Fixing clip for steel tape attachment 6... M A = 23 Nm/ W.a.f Tower RIBE-Order-No. B /AX BX Cable A Cable B Helical rods Mass/ Exe. Clamping range Exe. Clamping range RIBE-No. L Dia. No. of wires pcs mm mm mm mm kg 9 7,00-7,90 9 7,00-7,90 TW , ,91-8, ,91-8,79 TW ,59 1 8,80-10,09 1 8,80-10,09 TW , ,10-11, ,10-11,49 TW , ,50-13, ,50-13,10 TW ,90 3 0,4 4 13,11-14, ,11-14,81 TW , ,82-16, ,82-16,62 TW , ,63-18, ,63-18,53 TW , ,54-20, ,54-20,54 TW , ,55-22, ,55-22,55 TW , ,56-24, ,56-24,50 TW ,25 Part name RIBE-Order-No. Remark Steel tape B T7 to be ordered separately Fixing clip B T8 to be ordered separately Helical rods: Aluminium-clad steel U-bracket: Steel, h.d.g. Threaded bolt, nuts: Stainless steel A2-70 Bolt: Stainless steel A2-80 Fixing clip: Steel, h.d.g. Steel tape: Stainless steel Fixing clip: Stainless steel These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the tower consisting of steel rod, concrete or wood to the joint box. Remarks: Stand: 15. Mai 2006 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings for optical fibre aerial cables at rounded towers with steel ods, concrete or wood/ 82 / 103

84 The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B Order example: Cable A: 15,8 mm dia. Cable B: 21,2 mm dia. Fixing clamp: B /A5 B8 For other executions please inquire. Stand: 15. Mai 2006 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings for optical fibre aerial cables at rounded towers with steel ods, concrete or wood/ 83 / 103

85 B844/3 Fixing clamps with helical fittings for optical fibre aerial cables at wooden poles 1... Cable A 2... Cable B 3... W.a.f. 12 RIBE-Order-No. B /AX BX Cable A Cable B Helical rods Mass/ Exe. Clamping range Exe. Clamping range RIBE-No. L Dia. No. of wires pcs mm mm mm mm kg 1 7,00-7,90 1 7,00-7,90 TW ,59 2 7,91-8,79 2 7,91-8,79 TW ,59 3 8,80-10,09 3 8,80-10,09 TW , ,10-11, ,10-11,49 TW , ,50-13, ,50-13,10 TW ,90 3 0,4 6 13,11-14, ,11-14,81 TW , ,82-16, ,82-16,62 TW , ,63-18, ,63-18,53 TW , ,54-20, ,54-20,54 TW , ,55-22, ,55-22,55 TW , ,56-24, ,56-24,50 TW ,25 Helical rods: Aluminium-clad steel U-bracket: Steel, h.d.g. Washers: Stainless steel A2 Hexagonal bolt: Steel, h.d.g. Distance tube: Aluminium These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the wooden poles to the joint box. Remarks: The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B Order example: Cable A: 15,8 mm dia. Cable B: 21,2 mm dia. Fixing clamp: B /A7 B10 For other executions please inquire. Stand: 24. Juli 2008 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings for optical fibre aerial cables at wooden poles/ 84 / 103

86 B844/5 Fixing clamps with helical fittings at lattice towers 1... Cable A 2... Cable B 3... M A = 23 Nm/ W.a.f. 13 RIBE-Order-No. B /AX BX Cable A Cable B Helical rods Mass/ Exe. Clamping range Exe. Clamping range RIBE-No. L Dia. No. of wires pcs mm mm mm mm kg 1 7,00-7,90 1 7,00-7,90 TW ,59 2 7,91-8,79 2 7,91-8,79 TW ,59 3 8,80-10,09 3 8,80-10,09 TW , ,10-11, ,10-11,49 TW , ,50-13, ,50-13,10 TW ,90 3 0,4 6 13,11-14, ,11-14,81 TW , ,82-16, ,82-16,62 TW , ,63-18, ,63-18,53 TW , ,54-20, ,54-20,54 TW , ,55-22, ,55-22,55 TW , ,56-24, ,56-24,50 TW ,25 Helical rods: Aluminium-clad steel Nuts: Stainless steel A2-80 Bolt: Stainless steel A2-80 Washers: Stainless steel These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the tower consisting of steel to the joint box. Remarks: The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B Order example: Cable A: 15,8 mm dia. Cable B: 21,2 mm dia. Fixing clamp: B /A5 B8 For other executions please inquire. Stand: 15. Mai 2006 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings at lattice towers/ 85 / 103

87 B845 Filler bolts for fixing clamps Clamping range RIBE-Order-No. d Mass/ pcs Clamping range RIBE-Order-No. d Mass/ pcs mm mm kg mm mm kg 9,01-9,5 F /32 8,9 0,017 19,51-20,0 F /20 19,4 0,037 9,51-10,0 F /33 9,4 0,017 20,01-20,5 F /21 19,9 0,039 10,01-10,5 F /01 9,9 0,019 20,51-21,0 F /22 20,4 0,042 10,51-11,0 F /02 10,4 0,019 21,01-21,5 F /23 20,9 0,045 11,01-11,5 F /03 10,9 0,020 21,51-22,0 F /24 21,4 0,045 11,51-12,0 F /04 11,4 0,020 22,01-22,5 F /25 21,9 0,048 12,01-12,5 F /05 11,9 0,021 22,51-23,0 F /26 22,4 0,053 12,51-13,0 F /06 12,4 0,021 23,01-23,5 F /27 22,9 0,056 13,01-13,5 F /07 12,9 0,022 23,51-24,0 F /28 23,4 0,060 13,51-14,0 F /08 13,4 0,022 24,01-24,5 F /29 23,9 0,062 14,01-14,5 F /09 13,9 0,023 24,51-25,0 F /30 24,4 0,065 14,51-15,0 F /10 14,4 0,023 25,01-25,5 F /31 24,9 0,068 15,01-15,5 F /11 14,9 0,024 25,51-26,0 F /34 25,4 15,51-16,0 F /12 15,4 0,024 26,01-26,5 F /35 25,9 0,056 16,01-16,5 F /13 15,9 0,027 26,51-27,0 F /36 26,4 16,51-17,0 F /14 16,4 0,028 27,01-27,5 F /37 26,9 17,01-17,5 F /15 16,9 0,030 27,51-28,0 F /38 27,4 17,51-18,0 F /16 17,4 0,032 28,01-28,5 F /39 27,9 18,01-18,5 F /17 17,9 0,032 28,51-29,0 F /40 28,4 18,51-19,0 F /18 18,4 0,035 29,01-29,5 F /41 28,9 19,01-19,5 F /19 18,9 0,035 29,51-30,0 F /42 29,4 Filler bolt: Aluminium alloy Insert filler bolt in the second groove of the fixing clamp for optical fibre aerial cables when only one cable is guided down the tower. Remarks: Fixing clamps: see data-sheet B841/1, B841/2, B841/3 and B841/8 For other executions please inquire. Stand: 10. August 2006 Pfad: RIBE-Optofit/ Fixing clamps for tower attachment/ Filler bolts for fixing clamps/ 86 / 103

88 B850/0 Introducing to vibration dampers Aeolian vibrations: Under certain conditions phase conductors, ground wires and optical fibre aerial cables in transmission lines are excited to mechanical vibrations by wind. These are causing alternating bending stresses which superpose to the static tensile bending stress. Suspension- and tension points are especially endangered. As shown in practice for an undamped aerial cable these stresses cause fatigue breakages of single strands with the possible result of a complete breakage of the optical fibre aerial cable and subsequent breakdown. Efficient protection against aeolian vibration is given by the installation of suitable vibrations dampers. Purpose of vibration damper: Vibration dampers are combined frictional resonance dampers. Purpose of vibration dampers is to dissipate partly the wind power input on the conductor or optical fibre aerial cable to prevent critical cable stresses. Function of vibration damper: The vibration damper consists of a messenger wire with specially formed weights fixed on both ends. The clamp, to mount the damper on the conductor is fixed between the weights on the messenger wire and transfers the vibrations from the conductor or aerial cable to the messenger wire. The mechanical vibration energy is transformed within the messenger wire to heat caused by friction. High power dissipation within the small range of natural frequencies is a characteristic feature of most vibration dampers. Under field conditions, however, a wide band of natural conductor frequencies has to be expected. Therefore, the dampers must be effective within a wide frequency band and allow only small residual conductor/ aerial cable amplitudes. Selection of vibration damper: The vibration damper, i.e. it s mechanical properties (impedance), must fit for the conductor or optical fibre aerial cable. If not, either the damper can cause damages at its clamp on the conductor or aerial cable, or the damper itself can be destroyed. Location of vibration damper: To ensure the optimum efficiency of the vibration dampers, it is necessary to adapt the optimum damper design to the given conditions. This adaptation requires the determination of the exact damper placement and the number of dampers required. The most suitable vibration damper is ineffective if it is located in the vibration node, because the conductor or aerial cable is nearly not moving at this point and thus no vibration energy is transformed into heat. This case must be avoided by determination of a suitable location. If tension points are concernd this is often only possible with big efforts. In this case two dampers must be located on the conductor or optical fibre aerial cable nearby the tension point. Thus, it is for sure, that at least on damper is working. Damping concept: Every damper is capable to transform a certain amount of vibration energy into heat, without being overloaded. As the vibration energy is increasing with the length of the span, for longer spans several vibration dampers have to be installed. In special cases, as for example river crossings, additional damping has to be provided inside the span. The damping concept gives information about the damper location, the necessary quantity of dampers considering the length of the span and the type of damper (for example messenger wire made of stainless steel, clamping range etc.) The damping concept is developed with a computer vibration study. Given the conductor and damper properties, for every installationarrangement and span-length it is proven that the strain of conductors or optical fibre aerial cable (admissible bending strain = 150 µm/m) and vibration dampers remains uncritical and will not cause fatique breakages. Selection of vibration damper clamp: The selection of a suitable vibration damper clamp occurs after selection of the vibration damper type. The suitable clamp prevents excessive strain of optical fibres in a cable. For aerial cables additional protection rods are necessary. When determining the vibration damper clamp the total diameter resulting out of the aerial cable diameter plus two times the rod diameter of the protection rods has to be considered. By means of clamping tests the optimal clamp size and recommended tightening torque of the bolt are determined. Remarks: In the following catalog sheets vibration dampers of different sizes with different diameter ranges are shown. It must be underlined that this is Stand: 22. Mai 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Introducing to vibration dampers/ 87 / 103

89 only a rough classification. The exact determination and adjustment of the damper location is made by a calculation of the damper location or by a vibration study. Stand: 22. Mai 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Introducing to vibration dampers/ 88 / 103

90 B851/1 Vibration dampers with clamp attachment Fig. 1 Fig. 2 Fig. 3 Stand: 08. Mai 2007 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with clamp attachment/ 89 / 103

91 Fig. With messenger cable steel, h.d.g. and stainless steel bolt RIBE-Order-No. With messenger cable and stainless steel bolt Suitable for optical fibre aerial cable with diameter mm 1 F / X Kb F / X A2 Kb 14,0-19,0 4 Resonances 2,1-2,5 2 F / X Kb F / X A2 Kb 18,0-21,0 2 Resonances 2,6-3,3 2 F / X Kb F / X A2 Kb 21,0-26,0 2 Resonances 3,2-4,2 3 F / X Kb F / X A2 Kb 25,0-29,0 2 Resonances 5,9-6,3 3 F / X Kb F / X A2 Kb > 28 2 Resonances 8,0-8,3.../X.. - Determination of damper clamp is made by RIBE Type Mass/ pcs kg Weights figure no. 1 and 2: Forged steel, h.d.g. Weights figure no. 3: Steel, casting h.d.g. Clamp: Forgeds Aluminium alloy Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 08. Mai 2007 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with clamp attachment/ 90 / 103

92 B851/2 Vibration dampers with clamp attachment (with 3 resonances) RIBE-Order-No. With messenger cable steel, h.d.g. and stainless steel bolt With messenger cable and stainless steel bolt Suitable for optical fibre aerial cable with diameter Type Mass/ pcs mm kg F / X Kb F / X A2 Kb 9,0-16,0 3 Resonances 1,7-2,1.../X.. - Determination of damper clamp is made by RIBE Weights: Forgeds steel, h.d.g. Clamp: Forged aluminium alloy Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 18. August 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with clamp attachment (with 3 resonances)/ 91 / 103

93 B853/1 Vibration dampers with helical fixing RIBE-Order-No. Clamping range Helical rods H L Type Mass/ With messenger wire steel, h.d.g. With messenger wire stainless steel RIBE-No. Length Dia. No. of rods pcs mm mm mm mm mm kg F /8 F /8 A2 8,80-10,09 TW ,5 F /6 F /6 A2 10,10-11,49 TW ,5 F /1 F /1 A2 11,50-13,10 TW ,0 F /2 F /2 A2 13,11-14,81 TW , , Resonances 1,55 F /3 F /3 A2 14,82-16,62 TW ,0 F /4 F /4 A2 16,63-18,53 TW ,0 F /5 F /5 A2 18,54-20,54 TW ,0 F /7 F /7 A2 20,55-22,55 TW ,5 Weights: Forged steel, h.d.g. Clamp: Extruded profile Armor rods: Aluminium-clad steel Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 09. Mai 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with helical fixing/ 92 / 103

94 B853/2 Vibration dampers with helical fixing RIBE-Order-No. Clamping range Helical rods H L Type Mass/ With messenger wire Steel, h.d.g. With messenger wire Stainless steel RIBE-No. Length Dia. No. of rods pcs mm mm mm mm mm kg B /1 B /1 A2 18,50-20,20 TW ,0 B /2 B /2 A2 20,21-22,60 TW ,0 B /3 B /3 A2 22,61-25,20 TW ,5 B /4 B /4 A2 25,21-28,00 TW , , Resonances 2,5 B /5 B /5 A2 28,01-31,00 TW ,5 B /6 B /6 A2 31,01-34,00 TW ,5 B /7 B /7 A2 34,01-37,00 TW ,0 Weights: Forged steel, h.d.g. Clamp: Extruded profile Armor rods: Aluminium-clad steel Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 09. Mai 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with helical fixing/ 93 / 103

95 B853/3 Vibration dampers with helical fixing RIBE-Order-No. Clamping range Helical rods H L Type Mass/ With messenger wire Steel, h.d.g. With messenger wire Stainless steel RIBE-No. Length Dia. No. of rods pcs mm mm mm mm mm kg B /1 B /1 A2 18,50-20,20 TW ,0 B /2 B /2 A2 20,21-22,60 TW ,0 B /3 B /3 A2 22,61-25,20 TW ,5 B /4 B /4 A2 25,21-28,00 TW ,0 B /5 B /5 A2 28,01-31,00 TW , , Resonances 2,1 B /6 B /6 A2 31,01-34,00 TW ,5 B /7 B /7 A2 34,01-37,00 TW ,0 B /9 B /9 A2 14,00-16,00 TW ,5 B /10 B /10 A2 16,01-17,99 TW ,5 Weights: Forged steel, h.d.g. Clamp: Extruded profile Armor rods: Aluminium-clad steel Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 09. Februar 2009 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with helical fixing/ 94 / 103

96 B853/4 Vibration dampers with helical fixing RIBE-Order-No. Clamping range Helical rods H L Type Mass/ With messenger wire Steel, h.d.g. With messenger wire Stainless steel RIBE-No. Length Dia. No. of rods pcs mm mm mm mm mm kg B /1 B /1 A2 18,50-20,20 TW ,0 B /2 B /2 A2 20,21-22,60 TW ,0 B /3 B /3 A2 22,61-25,20 TW ,5 B /4 B /4 A2 25,21-28,00 TW , , Resonances 3,3 B /5 B /5 A2 28,01-31,00 TW ,5 B /6 B /6 A2 31,01-34,00 TW ,5 B /7 B /7 A2 34,01-37,00 TW ,0 Weights: Forged steel, h.d.g. Clamp: Extruded profile Armor rods: Aluminium-clad steel Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 09. Mai 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with helical fixing/ 95 / 103

97 B853/5 Vibration dampers with helical fixing RIBE-Order-No. Clamping range Helical rods H L Type Mass/ With messenger wire Steel, h.d.g. With messenger wire Stainless steel RIBE-No. Length Dia. No. of rods pcs mm mm mm mm mm kg B /1 B /1 A2 13,11-14,81 TW B /2 B /2 A2 14,82-16,62 TW B /3 B /3 A2 16,63-18,53 TW , Resonances 2,1 B /4 B /4 A2 18,54-20,54 TW B /5 B /5 A2 20,55-22,60 TW B /6 B /6 A2 22,61-25,20 TW Weights: Forged steel, h.d.g. Clamp: Extruded profile Armor rods: Aluminium-clad steel Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 09. Mai 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with helical fixing/ 96 / 103

98 B853/6 Vibration dampers with helical fixing RIBE-Orderlno. Clamping range Helical rods H L Type Mass/ With messenger cable Steel, h.d.g. With messenger wire Stainless steel RIBE-No. Length Dia. No. of rods pcs mm mm mm mm mm kg B /1 B /1 A2 13,11-14,81 TW B /2 B /2 A2 14,82-16,62 TW B /3 B /3 A2 16,63-18,53 TW , Resonances 2,5 B /4 B /4 A2 18,54-20,54 TW B /5 B /5 A2 20,55-22,60 TW B /6 B /6 A2 22,61-25,20 TW Weights: Forged steel, h.d.g. Clamp: Extruded profile Armor rods: Aluminium-clad steel Remark: The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE. Stand: 09. Mai 2006 Pfad: RIBE-Optofit/ Vibration dampers/ Vibration dampers with helical fixing/ 97 / 103

99 B855/2 Avibra-Vibration dampers for ADSS cables 1... Gripping section 2... Damping section RIBE-Order-No. Clamping range d L Mass/ pcs mm mm mm kg DB ,87-9,88 12, ,2 DB ,89-11,02 12, ,2 DB ,03-12,29 12, ,2 DB ,30-13,70 12, ,3 DB ,71-15,24 12, ,3 DB ,25-16,99 12, ,3 DB ,00-18,94 16, ,3 DB ,95-21,1 16, ,3 DB ,12-23,53 16, ,3 DB ,54-26,22 16, ,3 Helical rod: Weather-proof wear-resistant plastic Purpose of Avibra vibration dampers is to dissipate the wind power input on the ADSS cable to prevent critical conductor stresses. The Avibra vibration damper is composed of a helically formed plastic rod. About one fifth of the overall length of the helix is of smaller diameter. This section is used to attach the damper and provides a completely reliable grip on the ADSS cable so that the damper will not slip even on slopes. The remaining length of the helix has no close contact to the cable. Due to differential motions between ADSS cable and Avibra damper, the ADSS cable vibrations are eliminated. Installation: Avibra vibration dampers are installed by first wrapping the gripping section (smaller helix) and afterwards the damping section on the optical fibre aerial cable. The damper must be installed in such a way that the gripping section is placed towards the tower and the damping section towards the free span. No special tools are required for installation. Avibra vibration dampers can be installed without problems on any existing cable - even subsequently. For installtion follow RIBE-Mounting Instruction No. 17. Stand: 25. November 2010 Pfad: RIBE-Optofit/ Vibration dampers/ Avibra-Vibration dampers for ADSS cables/ 98 / 103

100 B860 Helically formed accessories for antenneas Protection rods and line splices from steel for glass fibre rods in antennae constructions Protection rods for glass fibre rods are mainly required for antennae constructions, protecting the glass fibre rods from mechanical influences like abrasion and compressive strains at the highly stressed points. Line splices are suitable for the full-tension connection of glass fibre rods. Cross-tie connectors from steel for glass fibre rods in antennae constructions Cross-tie rods are applied in antennae constructions connecting two crossing glass fibre rods mechanically. Dead ends from steel for glass fibre rods in antennae constructions Stand: 25. April 2006 Pfad: RIBE-Optofit/ Fittings for antennae/ Helically formed accessories for antenneas/ 99 / 103

EXCLUSIVE AUSTRALIAN DISTRIBUTORS

EXCLUSIVE AUSTRALIAN DISTRIBUTORS Helical Fittings EXCLUSIVE AUSTRALIAN DISTRIBUTORS B4/1 Introduction in helical fittings Helical fittings are composed of single helical rods which -according to the respective application - are separate

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

EARTH WIRE FITTINGS 08

EARTH WIRE FITTINGS 08 EARTH WIRE FITTINGS 08 8 EARTH WIRE FITTINGS 119 Contents General... 120 C-bracket... 123 Suspension clamp with bolt, with straps, for steel and copper conductors... 123 Suspension clamp with bolt, with

More information

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79 73 Contents General.................................................................................................. 74 Wedge tension clamp without jumper guide, for aluminium based conductors...........................

More information

SPACERS AND SPACER DAMPERS

SPACERS AND SPACER DAMPERS SPACERS AND SPACER DAMPERS 0 131 Contents General... 132 Spacer damper aluminium, for horizontal twin bundles... 138 Spacer damper aluminium, for vertical twin bundles... 138 Spacer damper aluminium, for

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged, for aluminium based conductors... 63 Suspension clamp trunnion type, forged, with bigger angle

More information

The reinforcing rods are incorporated in this assembly to ensure the optical fibres within the OPGW Range

The reinforcing rods are incorporated in this assembly to ensure the optical fibres within the OPGW Range OPGW Suspension Assemblies Optical Fibre Cable Same lay as OPGW outer stranding H Reinforcing rods opposite lay to OPGW outer stranding S L Application Heliformed suspension assemblies designed for use

More information

Company Profile. ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees.

Company Profile. ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees. Company Profile ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees. We provide products such as electrical fittings, optical

More information

S. K. Industrial Corporation

S. K. Industrial Corporation +91-8048763042 S. K. Industrial Corporation https://www.indiamart.com/skindlcorpn/ We are an ISO 9001 : 2008 certified company. We are manufacturing, exporting and supplying HT and LT transmission line,

More information

Installation Instructions

Installation Instructions Installation Instructions EXCLUSIVE AUSTRALIAN DISTRIBUTORS Mon9 Installation of helical dead ends General: Dead-end will be looped on delivery (fig.1). The particular wires of dead end are agglutinated

More information

Regulation for Installing

Regulation for Installing Regulation for Installing Phase Conductors and Earth Wires, as well as OPGW/OPPC (PCEWOP) made from aluminium, aluminium alloy, steel, aluminium clad steel, HACIN and combinations of these materials with

More information

Annexure B (1)- Engineering Instructions for Installation of Aerial OFC

Annexure B (1)- Engineering Instructions for Installation of Aerial OFC Annexure B (1)- Engineering Instructions for Installation of Aerial OFC INSTALLATION PRACTICE OF SELF SUPPORTING METAL FREE AERIAL OPTICAL FIBER CABLE 1. SCOPE: This Engineering Instruction (EI) deals

More information

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS Made from high impact, UV resistant, polyvinyl chloride (PVC), they are non-corrosive and do not abrade the conductor or require

More information

Section 6 FIBERLIGN Hardware for ADSS

Section 6 FIBERLIGN Hardware for ADSS FIBERLIGN Hardware for ADSS: Section 6 Section 6 FIBERLIGN Hardware for ADSS Table of Contents Page Fiber Optic Product Layout for ADSS...6-2 FIBERLIGN Lite Tension Dead-end for ADSS...6-3 FIBERLIGN Dielectric

More information

Section 5 Fiber Optics: FIBERLIGN Hardware for OPGW

Section 5 Fiber Optics: FIBERLIGN Hardware for OPGW FIBERLIGN Hardware for OPGW: Section Section Fiber Optics: FIBERLIGN Hardware for OPGW Table of Contents Page Fiber Optic Product Layout for OPGW...-2 FIBERLIGN ead-end for OPGW...-3 FIBERLIGN Formed Wire

More information

+91-8048571184 UB Exim Private Limited http://www.ubexim.in/ We are amongst the leading exporters, manufacturers, suppliers and traders, of this highly commendable and diverse range of Electrical Spares

More information

Helical dead-ends are installed on ADSS cables over medium spans (100 to 250 meters).

Helical dead-ends are installed on ADSS cables over medium spans (100 to 250 meters). Helical dead-ends are installed on ADSS cables over medium spans (100 to 250 meters). They consist of 4 armour rods installed as a direct protection on the cable and a spiral dead-end used as an anchor

More information

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor INS-ACA089 Installation Instructions Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor 1. Mark the conductor a distance of 3 /4 the length

More information

STEEL WIRE & ROPE FITTINGS

STEEL WIRE & ROPE FITTINGS 6 Beaver maintains a wide range of wire rope and fittings that can be used for towing and lifting applications. Furthermore Beaver has the ability to offer manufactured slings made to order. With Beaver

More information

PART NUMBER POLE DIAMETER RANGE CARTON QTY " to 5" " to 6 3 4" " to 7 3 4" " to 8 3 4" 10

PART NUMBER POLE DIAMETER RANGE CARTON QTY  to 5  to 6 3 4  to 7 3 4  to 8 3 4 10 PH1 Offset Pole Band Bands Single Double Offset Pole Bands are used for dead-ending, guying, and mounting secondary racks on metal poles, pipe masts, or conduit. Each Pole Band Assembly contains two 1

More information

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E 17 DISTRIBUTION OHL FITTINGS 01 Contents General... 3 Insulator pin straight with round thread, according to ÖNORM E4175... 5 Oscillating top clamp for aluminium based conductors... 5 Side tie for aluminium

More information

YOUR SPECIALIST AROUND CABLE AND WIRE. Catalog

YOUR SPECIALIST AROUND CABLE AND WIRE. Catalog Catalog "upi Cable- And wirestockings, Quality based on tradition The company rupi cologne is your perfect partner for anything in Cable and rope stockings. Since 1966 we have been the market leader in

More information

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS Sl. 1 260200003A STEEL TUBULAR POLE SWAGED 11 MTR. LONG WITH BASE 7651.62 8034.20 8435.91 PLATE & CAP (IS2713/1980) BTM: 165.1X4.5MM-5.6MTR,

More information

THERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR)

THERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR) Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR) July 2015 History of Hardware at PLP Preformed Line Products has been involved with the design, testing and production of hardware and

More information

Section 7 - Hardware & Fittings

Section 7 - Hardware & Fittings Transmission Transmission: Catalogue : Section 7 Section 7 - Table of Contents Sec/Page Table of Contents Sec/Page Aluminium Sheave... 7-6 Arcing Horn... 7-5 Ball 'Y' Clevis... 7-4 Ball Clevis... 7-8 Ball

More information

RICHARD BERGNER ELEKTROARMATUREN GMBH & CO. KG

RICHARD BERGNER ELEKTROARMATUREN GMBH & CO. KG POWER 03 RIBE ELECTRICAL FITTINGS Own design & development Safety you can rely on: Our experienced engineers develop varied solutions that give you convincing reliability in everyday operation in any situation.

More information

Bolted Dead End for OPGW

Bolted Dead End for OPGW Bolted Dead End for OPGW The AFL Dead End is a full tension termination for Optical Ground Wire cable. Breakaway head bolts are used to apply a precise gripping force to hold the cable without affecting

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17453-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.07.2017 to 02.07.2022 Holder of certificate: SPIE

More information

OPGW and ADSS Fiber Cable. For Overhead Transmission Lines

OPGW and ADSS Fiber Cable. For Overhead Transmission Lines OPGW and ADSS Fiber Cable For Overhead Transmission Lines PRYSMIAN GROUP VISION, MISSION, VALUES Vision The Prysmian Group believes in the effective, efficient and sustainable supply of Energy and Information

More information

Quintas & Quintas Group

Quintas & Quintas Group Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors

More information

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS Transmission: Section 1 NOMENCLATURE Single Support and Double Support : Identified by S and D appearing in the length column on the catalog page. Should the maximum distance between tied supports exceed

More information

TRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors

TRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors TRANSMISSION LINE REPAIR MANUAL A guidebook for the inspection and repair of damaged or worn conductors August 2017 PREFACE Since 1947 Preformed Line Products has been a recognized leader in the business

More information

DISTRIBUTION catalogue

DISTRIBUTION catalogue hardware & accessories jointing DISTRIBUTION catalogue Australian Manufactured Overhead Fittings for Power Distribution termination DISTRIBUTION catalogue protection Also available: Transmission Catalogue

More information

00000 Series Clevis Pin Slotted Hexagon Hex Key Recommended Corresponding Part No. Part No. Size Torque Preload SLT* SLT* HEX

00000 Series Clevis Pin Slotted Hexagon Hex Key Recommended Corresponding Part No. Part No. Size Torque Preload SLT* SLT* HEX 00000 Series Clevis Pin All clevis pins are manufactured from heat treated 416 stainless steel to provide superior strength and wear. Hardness is between 37-40 Rc. The DCD Clevis Pin is a shouldered type

More information

Volume-III : Section-I 370 Technical Specifications

Volume-III : Section-I 370 Technical Specifications Volume-III : Section-I 370 TECHNICAL SPECIFICATION-PIERCING INSULATOR 5.1 Insulation Piercing Connectors (IPC) 5.1.1 Insulation Piercing Connectors (IPC) are used for making Tee/Tap-off/Service connectors

More information

DESIGN OF MACHINE MEMBERS - I

DESIGN OF MACHINE MEMBERS - I R10 Set No: 1 III B.Tech. I Semester Regular and Supplementary Examinations, December - 2013 DESIGN OF MACHINE MEMBERS - I (Mechanical Engineering) Time: 3 Hours Max Marks: 75 Answer any FIVE Questions

More information

Table of Contents. Optical Ground Wire Hardware. Tools. Assemblies. ADSS Mini-Span Hardware. ADSS Hardware. Installation Instructions

Table of Contents. Optical Ground Wire Hardware. Tools. Assemblies. ADSS Mini-Span Hardware. ADSS Hardware. Installation Instructions Table of Contents Optical Ground Wire Hardware Bolted Dead End..................................... 3 Dead End Link Plate.... 6 Comealong......................................... 7 HIBUS OPGW Suspension...

More information

VORTXô VIBRATION DAMPER

VORTXô VIBRATION DAMPER VORTXô VIRTION DMPER ontoured lamp Technical Support - when you need it! PLP Motion ontrol Products VORTXô Vibration Damper From the Recognized Leader in onductor Protection Much of PLP s business has

More information

Conductor Protection. results

Conductor Protection. results Conductor Protection results Conductor Protection Index Dampers 607... Vibration Damper 4R Stockbridge...1 Armor Rods AP8... Aluminum Armor Rods...6 APS... alvanized Steel Armor Rods...8 APAS... AluminumClad

More information

Catenary Components For Local Transport Systems

Catenary Components For Local Transport Systems Catenary Components For Local Transport Systems RIBE a family business where tradition meets entrepreneurship and innovation Johannes Wilhelm Hofmann founded his Fabrik elektrischer Apparate in Kötschenbroda

More information

Overhead transmission lines Spacers

Overhead transmission lines Spacers = SVENSKA KRAFTNÄT SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AEL, Asset Management Lines OUR REFERENCE TR05-08E DATE 2016-06-09 CONSU12TATIONS TECHNICAL GUIDELINE REVISION 3 APPROVED Overhead transmission

More information

CRANE SET BRIDGE CRANE COMPONENTS

CRANE SET BRIDGE CRANE COMPONENTS CRANE SET BRIDGE CRANE COMPONENTS TO CREATE YOUR CUSTOM BRIDGE CRANE A series of products conceived and designed to be assembled and create a bridge crane suited to your needs STANDING BRIDGES 1 2 4 5

More information

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 3 Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 1 Contents Installation Guidelines and Maintenance for ACCR Aluminum Conductor Composite Reinforced 1. Introduction 4 2.

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 1 Contents Installation Guidelines and Maintenance for 3M ACCR Aluminum Conductor Composite Reinforced 1. Introduction.4

More information

ROSTA MOTORBASES ROSTA. Self-Tensioning Motor Mount for Belt Drives. without slippage self-adjusting maintenance-free

ROSTA MOTORBASES ROSTA. Self-Tensioning Motor Mount for Belt Drives. without slippage self-adjusting maintenance-free MOTORBASES Self-Tensioning Motor Mount for Belt Drives without slippage self-adjusting maintenance-free Technology Tensioning Motorbase Type MB for Belt Drives The elastic tensioning motorbase type MB,

More information

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows: QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which

More information

ROSTA Tensioner Devices

ROSTA Tensioner Devices 33 Tensioning Technology Chain Tensioning Roller chains are power transmission components with positive transmission which, by virtue of their design are subject, depending on quality, to elongation as

More information

Townsend Bearings. Rosta Tensioner Devices. Revision 1

Townsend Bearings. Rosta Tensioner Devices. Revision 1 Townsend Bearings Rosta Revision 1 Tensioning Technology Chain Tensioning Roller chains are power transmission components with positive transmission which, by virtue of their design are subject, depending

More information

ROSTA Tensioning Motorbases Type MB. self-adjusting maintenance-free overload-proof non-slip dampen harmful vibrations extend belt drive

ROSTA Tensioning Motorbases Type MB. self-adjusting maintenance-free overload-proof non-slip dampen harmful vibrations extend belt drive 83 Technology ROSTA Tensioning Motorbase Type MB for Belt Drives The ROSTA elastic tensioning motorbase type MB, with the rubber suspension unit as swivel mounting, compensates continuously for all stretching,

More information

DICTATOR RTS Tube Door Closer

DICTATOR RTS Tube Door Closer DICTATOR RTS Tube Door Closer The "Invisible" Door Closer The DICTATOR RTS tube door closer is virtually invisible because being built into the door. The joint can only be seen when the door is open. The

More information

150 lb. Hopper Assembly

150 lb. Hopper Assembly 1819-3 2/05 The Assembly is NOT designed for single-point suspension. The upper cross brace is designed for supporting the drop tube ONLY. This Hopper Assembly is to have Two-point suspension as stated

More information

VORTX Vibration Damper

VORTX Vibration Damper Product Identification 1 2 3 5 4 NOMENLTURE 1. lamp & Keeper: The lamp has an extruded hook shaped profile to hang onto the cable or conductor while tightening the keeper. Together, the aluminum keeper

More information

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE The hardware fittings suitable for tension string to be used for 11KV consisting of following

More information

ROSTA Tensioning Motorbases Type MB. self-adjusting maintenance-free overload-proof non-slip dampen harmful vibrations extend belt drive

ROSTA Tensioning Motorbases Type MB. self-adjusting maintenance-free overload-proof non-slip dampen harmful vibrations extend belt drive Technology ROSTA Tensioning Type MB for Belt Drives The ROSTA elastic tensioning motorbase type MB, with the rubber suspension unit as swivel mounting, compensates continuously for all stretching, hopping,

More information

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable ...... ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable Water Blocking Binders... Ripcord Optical Fibers...... Flexible Buffer Tube Jacket (polyethylene) (3.0 mm) Aramid Strength Yarns......

More information

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2

More information

BEARINGS The lower bearing assemble is constructed to allow continuous operation when fully submerged in wastewater.

BEARINGS The lower bearing assemble is constructed to allow continuous operation when fully submerged in wastewater. GENERAL SPECIFICATION INTENT The equipment to be supplied by manufacturer includes the screw pumps, support for the drive unit, profile plates, motors, gearboxes, couplings, guards, upper and lower bearing

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

Product Range Modules ROSTA Tensioner Devices

Product Range Modules ROSTA Tensioner Devices Product Range Modules ROSTA Page 17 14 Tensioning Technology Chain Tensioning Roller chains are power transmission components with positive transmission which, by virtue of their design are subject, depending

More information

One-way Clutches Tension Pulleys, Bottom Roller Bearings

One-way Clutches Tension Pulleys, Bottom Roller Bearings One-way Clutches Tension Pulleys, Bottom Roller Bearings One-way clutches One-way Clutches This is a compact and roller type one-way clutch which formed a cam face on its outer ring. (Available shaft diameter

More information

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver TECHNICAL SPECIFICATION FOR Optical Fiber Overhead Ground Wire (OPGW) Designer Approver SPEC No.: ZP10-15389 REVISION: 1.1 Technical Supporter ZP Int ternational Division Chief Technical Engineer ZP Int

More information

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter.

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. Experiment o. 1 AME OF THE EXPERIMET To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. OBJECTIVE 1. To be conversant with the constructional detail and working of common

More information

Wire rope slings 2011/12

Wire rope slings 2011/12 TransportTransportundund Hebegeräte Hebegeräte Wire rope slings Wire rope slings, 1/2/4-leg... 138 Combined rope/chain suspension gears... 6 Endless wire rope slings... 7 Wire rope sling accessories...

More information

SCHEDA TECNICA. Sospensione per cavo 13,5 mm MS214A00 Sospensione per cavo 16,5 mm MS220A00. Description: Suspension clamp for cable 13,5mm and 16,5mm

SCHEDA TECNICA. Sospensione per cavo 13,5 mm MS214A00 Sospensione per cavo 16,5 mm MS220A00. Description: Suspension clamp for cable 13,5mm and 16,5mm SCHEDA TECNICA Sospensione per cavo 13,5 mm MS214A00 Sospensione per cavo 16,5 mm MS220A00 Code : MS214A00 MS220A00 Description: Suspension clamp for cable 13,5mm and 16,5mm Material: Clamp body, keeper,

More information

CONTENT. 1. Syllabus 2. Introduction 3. Shaft 4. Coupling. Rigid coupling. Flange coupling. Sleeve (or) muff coupling Split muff coupling

CONTENT. 1. Syllabus 2. Introduction 3. Shaft 4. Coupling. Rigid coupling. Flange coupling. Sleeve (or) muff coupling Split muff coupling UNIT II 1. Syllabus 2. Introduction 3. Shaft 4. Coupling Rigid coupling CONTENT Flange coupling Protected flange coupling Unprotected flange coupling Marine type flange coupling Sleeve (or) muff coupling

More information

ezspan ADSS All-dielectric self-supporting loose tube cable

ezspan ADSS All-dielectric self-supporting loose tube cable All-dielectric self-supporting loose tube cable MANUFACTURED IN Aramid Strength Yarns Inner Jacket Polyethylene (optional) Central Strength Member Water Blocking Material Gel-Filled Buffer Tube Containing

More information

Section 4 - Protection

Section 4 - Protection Transmission Catalogue : Section 4 Protection Section 4 - Protection Table of Contents Section/Page PREFORMED Armor Rods For AAC, AAAC and ACSR s... 4-3 For AAC, AAAC and ACSR s (Subset)... 4-3 For SC/GZ

More information

CABLE CLAMPS FOR LOW AND HIGH VOLTAGE CABLES

CABLE CLAMPS FOR LOW AND HIGH VOLTAGE CABLES CABLE CLAMPS FOR LOW AND HIGH VOLTAGE CABLES Bauteile für die Elektrotechnik GmbH An der Molkerei 15 56288 Kastellaun Phone +49 6762 5658 Fax +49 6762 6638 w w w. id-technik.com info @ id-technik.com Cable

More information

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS HV EARTHING AND SHORT CIRCUIT LANCE DEVICE For use on maintenance operation and reparation of system parts electrically insulated of interconnection station of hv with air insulation: on coloumn support

More information

STRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS

STRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS 172 Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com STRAIN LINK STICK Used as insulation between rope blocks and a hot line wire grip For deadend structures and running corners Attached to conductor

More information

Standard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes

Standard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes Standard Rope Pull Switches With and Without ing Function SEK SEM2 SIEM2 SD SID SID SIN SGC SI88 Because of their specifications governed by corresponding standards (see Cable Safety Pull Switches SRM/SR),

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

Transmission Tools. Catalog 2250 May Transmission Tools Phone: Web: hubbellpowersystems.

Transmission Tools. Catalog 2250 May Transmission Tools Phone: Web: hubbellpowersystems. Transmission Tools Catalog 2250 May 2016 Transmission Tools 2250 May 2016 Page 2251 STRAIN LINK STICK Tested per OSHA & ASTM F711 Used as insulation between rope blocks and a hot line wire grip For deadend

More information

WARRANTY TERMS AND CONDITIONS OF SALE

WARRANTY TERMS AND CONDITIONS OF SALE WARRANTY Products manufactured by Coastal Line Products (CLP) are warranted to be of good workmanship and material for a period of three years from date of delivery. This warranty applies only to products

More information

Lightweight. Geislinger Gesilco

Lightweight. Geislinger Gesilco Lightweight Geislinger Gesilco The Geislinger Gesilco product range is based on more than 20 years of experience in developing fibre composite couplings and shafts. The maintenance-free composite membranes

More information

Stringing Tools and Plants. Global exports to 30+ countries. Qureishi Enterprises th

Stringing Tools and Plants. Global exports to 30+ countries. Qureishi Enterprises th Stringing Tools and Plants Global exports to 30+ countries www.kashvicommunications.com ENTERPRISES Qureishi Enterprises th 5 Floor, AZA House, 24, Turner Road, Bandra (W), Mumbai - 400 050, INDIA. Phone:

More information

CHICAGO HARDWARE & FIXTURE COMPANY

CHICAGO HARDWARE & FIXTURE COMPANY CHICAGO HARDWARE & FIXTURE COMPANY Manufacturers of Wire Rope and Cha Fittgs, Industrial and Mare Hardware and Allied Products Sales offices and warehouse stocks are mataed the prcipal cities to enable

More information

TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-ACSR PANTHER CONDUCTOR FOR TRANSMISSION LINE

TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-ACSR PANTHER CONDUCTOR FOR TRANSMISSION LINE GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-ACSR PANTHER CONDUCTOR FOR TRANSMISSION LINE GETCO/ENGG/TECH.

More information

Australian Manufactured Fittings & Accessories for Communication Networks. Also available:

Australian Manufactured Fittings & Accessories for Communication Networks. Also available: Australian Manufactured Fittings & Accessories for Communication Networks Also available: Transmission Catalogue Substation Catalogue Distribution Catalogue Preformed Line Products Preformed Line Products

More information

Locks and Catches Information

Locks and Catches Information Information SYMO 3000 is the worldwide unique furniture locking system from Häfele. Without tools and time-consuming installation, it provides maximum flexibility at minimum expenditure and effort. The

More information

produces and delivers products worldwide can provide the optimal solution for your requirements. are dedicated to supplying you with

produces and delivers products worldwide can provide the optimal solution for your requirements. are dedicated to supplying you with www.ppcinsulators.com The very Best. The very Best. That s what we deliver. Only a company that develops, produces and delivers products worldwide can provide the optimal solution for your requirements.

More information

CHAIN & HOOKS. Proof Coil Chain Grade 28. Transport Chain Grade 70

CHAIN & HOOKS. Proof Coil Chain Grade 28. Transport Chain Grade 70 Proof Coil Chain Grade 28 Proof coil chain is suitable for use as towing chain, logging,fencing, trailer safety chain, boat anchors, security barriers or other general purposes where chain of high tensile

More information

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS) Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE IN THE OPTI-GUARD SPLICE ENCLOSURE (HEXACORE CABLE DESIGNS) NOTE: EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT, THESE DRAWINGS AND/OR SPECIFICATIONS

More information

Power Transmission Equipment. Allbest Creative Development Ltd. (ALLBEST)

Power Transmission Equipment. Allbest Creative Development Ltd. (ALLBEST) Power Transmission Equipment Allbest Creative Development Ltd. (ALLBEST) Technology Portfolio Integrated Technology and Equipment for Power Substation & Transmission Line Substation Steel Tube Tower for

More information

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device TECHNICAL INFORMATION Dipl.-Ing. (FH) Christian Niklis Stationary Lance Earthing Device GENERAL Lance earthing devices - What s s the use of them? Short-circuit-proof earthing in high voltage substations

More information

Transformer Bushing Type EKTO

Transformer Bushing Type EKTO Transformer Bushing Type EKTO Mounting Operating and Maintenance Instructions Operating Instructions BAL EKTO/04e Visum 01/14 T/gue Page 1 of 16 SAFETY INSTRUCTIONS These instructions are valid for mounting,

More information

Caring for cables. Types of installation

Caring for cables. Types of installation Caring for cables Cable carriers guide and protect cables and hoses on moving machinery, and prevent tangling or damage from debris or contact with the machine itself. Proper use of a cable carrier extends

More information

TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE

TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE GETCO/E/TS

More information

America s Largest Importer/Wholesaler of Wire Rope, Chain and Fittings!

America s Largest Importer/Wholesaler of Wire Rope, Chain and Fittings! America s Largest Importer/Wholesaler of Wire Rope, Chain and Fittings BLOCKS BINDERS Failure to design and use tackle block systems properly may cause a load to slip or fall - the result could be serious

More information

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor

More information

Bolt tensioning device

Bolt tensioning device Bolt tensioning device 1 Performance variations - Examples 2 Bolt tensioning devices for a forgin press Bolt tensioning device for a extruding machine 3 Areas of application, conditions and advantages

More information

Proposed Short circuit test: The attenuation coefficient to max allowed increased 0.05 db/km from the point of strike.

Proposed Short circuit test: The attenuation coefficient to max allowed increased 0.05 db/km from the point of strike. Proposed Short circuit test: The attenuation coefficient to max allowed increased 0.05 db/km from the point of strike. Test 1 2 3 Short-circuit current 6kA 9kA 20kA Duration 1.0Sec 0.5Sec 0.1Sec 46 Proposed

More information

FRICTION DEVICES: DYNAMOMETER. Presented by: RONAK D. SONI Assistant Professor Parul Institute of Technology, Parul University

FRICTION DEVICES: DYNAMOMETER. Presented by: RONAK D. SONI Assistant Professor Parul Institute of Technology, Parul University FRICTION DEVICES: DYNAMOMETER Presented by: RONAK D. SONI Assistant Professor Parul Institute of Technology, Parul University DYNAMOMETER A dynamometer is a brake but in addition it has a device to measure

More information

LINE FITTINGS I N D E X

LINE FITTINGS I N D E X LINE FITTINGS I N D E X LINE FITTINGS Anchor Shackles Type AS. Page C-2 Ball Eye Links Type BEL...Page C-3 Ball Clevis Type BC. Page C-4 Clevis Tongues Type CT.Page C-5 Twisted Clevis Tongues Type TCT.

More information

DNV-GL HH CE RoHS-II conform

DNV-GL HH CE RoHS-II conform Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable

More information

SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE

SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE The hardware fittings suitable for tension string to be used for 11KV / 22 KV consisting of following components.

More information

Engineering Data Tensioner Arms idler Sprocket Sets Idler Roller Pulley Sets

Engineering Data Tensioner Arms idler Sprocket Sets Idler Roller Pulley Sets CHAIN & PULLEY TENSIONERS Engineering Data Tensioner Arms idler Sprocket Sets Idler Roller Pulley Sets ENGINEERING DATA TENSIONING TECHNOLOGY Chain & V-Belt Tensioning Roller chains are power transmission

More information

SCHMIDT-KUPPLUNG GmbH

SCHMIDT-KUPPLUNG GmbH Loewe GK About us Many years of experience For 50 years, we have been advising machine manufacturers as partners for compact coupling systems. Our experience in power transmission has given us extensive

More information