1 E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,, and. Non-stationary electrical apparatus have generally high requirements on the energy/power supply. Robust plugs and receptacles as well as a high chemical resistance are at the first glance very important. Electrical reliability is a must not only for all connectivity products. A high safety standard, a steady hold and faultless contacting even under vibration or the effects of an aggressive atmospheric environment are the basis for a secure and reliable utilisation CEAG plugs and receptacles offer more, apart from the proven technology, this product series is defined by its innovative details. For example, the very efficient cable strain relief or the new coding system of the various versions offers different solutions for a secure and problem free utilization in all areas. Just to round the product off, the user in the normal industrial sector becomes exactly the same product advantages. Robust industrial versions fulfil all requirements appertaining to mechanical and chemical dura - bility. For the stationary repair power supplying in hazardous explosive areas, there is a specially conceived version available that fulfils all the necessary safety requirements. Used in a module sense, individual solutions are no problem at all. The CEAG wall socket for instance can be mounted on to the pre-installed mounting frame without having to use tools installation without a hot work permit. Apart from the plugs and receptacles for the European market, we also have plugs and sockets extra for the US market, which are in accordance to all of the necessary standards UL and safety protection systems used there. The available standard range used here, are the 0 A, 0 A, 0 A and 0 A. International approvals. Nickel-plated contacts Low insertion force Safety standard IP applies also in the plugged-in state Full AC- switching ability Self-cleaning lamellar contacts, low transition resistance All-pole on/off switching Easy plugging.
2 I Ex-s and Receptacles I High ingress protection been withdrawn, the sockets and The new plugs and receptacles reliably couplers fulfil the requirements for the supply electrical power, even under degree of protection IP; and thanks the most difficult circumstances. From to the type of bayonet ring, the degree minus 0 C to plus C there are of protection IP is also ensured when no problems due to the ingress of water the plug is inserted and energized we or dirt, because when the plug has have tested it! CEE plugs and receptacles A first step towards creating an inter - national standard for industrial plugs and receptacles was taken with the IEC 00 and CEE Publication, Requirements for s and Receptacles for Industrial Use. IEC stands for INTERNATIONAL ELECTRICAL COMMISSION. When selecting plugs and receptacles from the existing ranges for standardization, preference was given to round plugs and receptacles, as the contactmaking insert can be arranged in various positions (hours of day). This allows a high degree of differentiation of plugs and receptacles with regard to the various types of currents, voltages, frequencies, etc. Ground pin Number of pins (P = Power, N = Neutral, PE = Earth or Ground) location P + PE P + PE P + N + PE P + N + PE h >0 V, Hz, only A/ A >0 V, Hz, only A/ A >0 V, Hz, only A/ A green housing green housing green housing h 0 V, 0 Hz, nur A/ A 0/0 V, 0 Hz, only A/ A 0 V, 0 Hz, nur A/ A ) 0/0 V, 0 Hz, only A/ A ) red housing red housing h 0-0 V, 0 0 Hz 0-0 V, 0 0 Hz /0 - /0 V, 0 0 Hz yellow housing yellow housing yellow housing h V, 0 Hz 00-0 V, 0/0 Hz /00-00/0 V, 0/0 Hz grey housing black housing black housing h 00-0 V, 0 0 Hz 0 - V, 0/0 Hz 00/ - 0/ V, 0/0 Hz blaues Gehäuse red housing red housing h 0-00 V, 0 0 Hz 0-00 V, 0/0 Hz /0 - /00 V, 0/0 Hz grey housing grey housing grey housing h > 0 V Gleichspannung grey housing h 0 - V, 0 0 Hz 00-0 V, 0/0 Hz 0/0 - /0 V, 0/0 Hz red housing blue housing blue housing h > 0 V, 0-00 Hz green housing h 0-0 V, 0 Hz ) 0/00 - /0 V, 0 Hz ) red housing red housing h 0-0 Hz ) 0/0 Hz ) grey housing grey housing ) for reefer container; ) for ships; ) Output of an isolation transformer with more than 0V COOPER CROUSE-HINDS GMBH.
3 I Ex-s and Receptacles I wall socket GHG... old wall socket GHG... old series series GHG... Zone Zone Industry Coding of the plugs and receptacles The key to safety s and receptacles with a cleverness: The innovative coding of apparatus allows plugs used for Zone to be used in receptacles for Zone and/or for usage with industrial receptacles as well. Hence, plugs and receptacles for Zone can be used anywhere. However, by the same token, the coding ensures that Zone plugs cannot be operated in sockets with Zone coding. That guarantees safety with an enormous flexibility in their usage. Speaking of flexibility: It goes without saying that the plugs of the existing range also fit into the new receptacles. plug GHG.. Zone / Zone / Industry/Non-Ex possible not possible Combination of possible/not possible connections of plug/wall socket Zone / Zone / Industry/Non-Ex.0 COOPER CROUSE-HINDS GMBH
4 I A -/-pole transf. plug I I with fuse I Technical data Transformer plug Ex-transformer plug acc. to IEC 00-/, up to V Marking to //EC II G Ex ed IIC T EC-Type Examination Certificate PTB ATEX IECEx type of protection Ex ed [ia] IIC T/T IECEx certification of conformity IECEx BKI Permissible ambient temperature -0 C to + 0 C Rated voltage primary V AC Rated voltage secondary V, V, V, V or 0 V~ Frequency 0-0 Hz Power consumption max. VA Back up fuse, internal 0. A mt, replaceable Connecting terminals x - mm Insulation class I Degree of protection to EN 0 IP Cable glands Ø - 0 mm Glass-fibre reinforced polyester, polyamide Ordering details Voltage h Type Weight approx. Sec voltage Order No. A transformer plug -pole 00-0 V Transformer plug VA. kg V GHG V0000 Transformer plug VA. kg V GHG V00 Transformer plug VA. kg V GHG V0 A transformer plug -pole 0- V Transformer plug VA. kg V GHG V0000 Transformer plug VA. kg V GHG V00 Transformer plug VA. kg V GHG V0 Transformer plug VA. kg 0 V GHG V0 with fuse 00-0 V with fuse max.. A. kg GHG V0000 Accessories cap / pole cap pole Dimension drawing GHG 0 R000 GHG 0 R000 Ø 0 Ø 0 Ø Transformer plug Dimensions in mm COOPER CROUSE-HINDS GMBH.
5 I A -pole up to 0 V I I A -pole up to 0 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, - and -pole acc. to IEC 00-/ Marking to //EC II G Ex de [ia] IIC T/T EC-Type Examination Certificate, plug and coupler: PTB ATEX Flange socket: PTB ATEX U IECEx certification of conformity IECEx BKI IECEx type of protection Ex ed [ia] IIC T/T Permissible ambient temperature C to + C Rated voltage up to 0 V Rated current A Frequency up to 00 Hz Rated making/rated breaking capacity AC- accd. EN 0- Ue 0 V / Ie A External back-up fuse, max. without therm. protection: A / with therm. protection: A Degree of protection to EN 0 IP (IP optional) Cable glands x M Ø - mm, x M Ex-screw plug plastic (bottom) or x metal thread M0 with Ex-screw plug plastic Connecting terminals x. - mm Glass-fibre reinforced polyester Cabel glands Ø - mm Connecting terminals.0 - mm Polyamide Coupler Cabel glands Ø - mm Connecting terminals. - mm Polyamide Flange socket Connecting terminals. - mm Polyamide. COOPER CROUSE-HINDS GMBH
6 I A -pole up to 0 V I I A -pole up to 0 V I Ordering details Coupler Flange socket Voltage h Type Cable entries Weight approx. Order No. Type -pole low voltage V M KU. kg GHG 00 R000 Flange socket 0. kg GHG 00 V0000 Coupler 0. kg GHG 00 R000 no aux. keyway 0. kg GHG 00 V0000 V M KU. kg GHG R000 Type -pole low voltage Flange socket 0. kg GHG V0000 Coupler 0. kg GHG R kg GHG V0000 V M KU. kg GHG 00 R000 Flange socket 0. kg GHG 00 V0000 Coupler 0. kg GHG 00 R000 no aux. keyway 0. kg GHG 00 V0000 V M KU. kg GHG R000 Flange socket 0. kg GHG V0000 Coupler 0. kg GHG R kg GHG V0000 Other voltage ranges and versions available on request Accessories Type Application Fixing method Order No. Mounting plate size wall mounting snap on for GHG / pole GHG R0 Mounting plate size wall mounting snap on for GHG pole GHG R0 Protective canopy size puggable GHG R0 Dimension drawing 0 X0 X X X Flange socket M Ø Drilling for flange socket. Coupler X = fixing dimensions Ø COOPER CROUSE-HINDS GMBH. ~0 Dimensions in mm
7 I A -pole, -pole and -pole up to 0 V I Flange socket Coupler Technical data Ex-plugs and receptacles acc. to IEC 00-/ A Marking to //EC II G Ex ed IIC T / II D Ex td A IP T0 C EC-Type Examination Certificate, plug and coupler: PTB ATEX Flange socket: PTB ATEX 0 U IECEx certification of conformity IECEx BKI IECEx type of protection Ex ed [ia] IIC T/T Permissible ambient temperature -0 C to +0 C ) Rated voltage up to 00 V (-pole) / 0 V (-pole) / 00 V (-pole) AC Rated current A Frequency up to 00 Hz Rated making/rated breaking capacity AC- accd. EN 0- Ue 0 V / Ie A External back-up fuse, max. without therm. protection: A with therm. protection: A gl (rated current A set to) Insulation class I Degree of protection to EN 0 IP Cable glands x M Ø - mm, x M Ex-screw plug plastic or x metal thread M0 with Ex-screw plug plastic Connecting terminals x - mm Glass-fibre reinforced polyester Cable glands Ø - mm (-pole) / Ø - mm (-pole) / - mm (-pole) Connecting terminals x.0 -. mm polyamide Coupler Cable glands Ø - mm (-pole) / Ø - mm (-pole) / - mm (-pole) Connecting terminals x - mm polyamide Flange socket Connecting terminals x - mm polyamide ) extended temperature range on request Ordering details Voltage h Type Auxiliary contact Cable entries Weight approx. Order No. Type A -pole 0-0 V M KU. kg GHG 0 R000 M0 GE. kg GHG 0 R000 M0 ME. kg GHG 0 R00 M0 GM. kg GHG 0 R00 Flange socket 0. kg GHG 0 R000 Coupler 0. kg GHG 0 R kg GHG 0 R000. COOPER CROUSE-HINDS GMBH
8 I A -pole, -pole and -pole up to 0 V I Ordering details Coupler Flange socket Voltage h Type Auxiliary contact Cable entries Weight approx. Order No. Type A -pole 00-0 V M KU. kg GHG 0 R000 M0 GE. kg GHG 0 R000 M0 ME. kg GHG 0 R00 M0 GM. kg GHG 0 R00 Flange socket 0. kg GHG 0 R000 Coupler 0. kg GHG 0 R kg GHG 0 R000 Type A -pole 00-0 V M KU. kg GHG 0 R000 M0 ME. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R V M KU. kg GHG 0 R000 M0 ME. kg GHG 0 R00 yes M KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R V M KU. kg GHG 0 R000 M0 ME. kg GHG 0 R00 yes M KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R V M KU. kg GHG 0 R000 M0 ME. kg GHG 0 R00 yes M KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R000 Type A -pole 00-0 V M KU. kg GHG 0 R V M0 ME. kg GHG 0 R00 yes M KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R000 Other voltage ranges and versions available on request. KU = x plastic cable glands M for Ø - mm, x M Ex-screw plug plastic KH = x plastic cable glands M for Ø - mm,, NO ME = x metal thread M0 with Ex-screw plug plastic GE = x plastic thread M0 without cable gland/screw plug GM = x metal thread M0 without cable gland/screw plug COOPER CROUSE-HINDS GMBH.
9 I A -pole, -pole and -pole up to 0 V I Flange socket Coupler Dimension drawing Wiring diagram 0 X0 0 X0 -pole -pole Coupler -pole Flange socket -pole Dimensions in mm X X /-pole ~. (-pole) (-pole) /-pole ~ 0. (-pole). (-pole 0 Coupler /-pole ~ X,, (-pole) (-pole). X X X, Flange socket /-pole X = fixing dimensions without without with without with L N PE L L L PE L L L PE L L L N PE L L L N PE P + N + PE P + PE P + AUX + PE P + N + PE P + N + AUX + PE. COOPER CROUSE-HINDS GMBH
10 I A -pole, -pole and -pole up to 0 V I Protective canopy cap GHG R0 Accessories Mounting plates for wall sockets A Type Application Fixing method Order No. Size for wall mounting snapped on GHG R0 Size for trellis mounting snapped on GHG R0 Size for pipe mounting snapped on GHG R00 cap for plugs A Type A -pole A -pole A -pole Accessories for mounting plates Order No. GHG R000 GHG R000 GHG R000 Type OU Order No. Mounting set for pipes (Ø - 0 mm) for mounting plates with pipe fixing GHG R000 Please pay attention to that only order units (OU) according to the ordering details can be delivered. Protective canopy for mounting plate Type Application Order No. Size for mounting plate size plugable GHG R0 Dimension drawing.. Mounting plate size for wall/trellis mounting Mounting plate size for pipe mounting Protective canopy size COOPER CROUSE-HINDS GMBH. Dimensions in mm
11 I A -pole up to 0 V I I A -pole up to V I Flange socket Coupler Technical data Ex-plugs and receptacles accd. to IEC 00-/ Marking to //EC II G Ex de (ia) IIC T / II D Ex td A IP T0 C EC-Type Examination Certificate, plug and coupler: PTB ATEX Flange socket: PTB ATEX U IECEx certification of conformity IECEx BKI IECEx type of protection Ex ed [ia] IIC T/T Permissible ambient temperature -0 C to +0 C ) Rated voltage up to 0 V (AC) Rated current A Frequency up to 00 Hz Rated making/rated breaking capacity AC- accd. EN 0- Ue 0 V / Ie A External back-up fuse without therm. protection: A with therm. protection: 0 A gl (rated current A set to Insulation class I Degree of protection accd. EN 0 IP Enclosure colour black Cable glands/enclosure drilling x M0 Ø - mm, x M0 Ex-screw plug plastic or x M metal thread with Ex-screw plug plastic Connecting terminals x - mm Glass-fibre reinforced polyester Cabel glands Ø - mm Connecting terminals.0 - mm Polyamide Coupler Cabel glands Ø - mm Connecting terminals x - mm Polyamide Flange socket Connecting terminals x - mm Polyamide ) extended temperature range on request. COOPER CROUSE-HINDS GMBH
12 I A -pole up to 0 V I I A -pole up to V I Ordering details Coupler Flange socket Voltage h Type Auxiliary contact Cable entries Weight approx. Order No. Type A -pole 00-0 V KU. kg GHG 0 R000 ME. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R000 Type A -pole 00-0 V KU. kg GHG 0 R V ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 Flange socket.0 kg GHG 0 R000 Coupler. kg GHG 0 R kg GHG 0 R000 Other voltage ranges and versions available on request. KU = x plastic cable glands M0 for Ø - mm, x M0 Ex-screw plug plastic KH = x plastic cable glands M0 for Ø - mm, x plastic cable glands M for Ø - mm, with ME = x metal thread M with Ex-screw plug plastic COOPER CROUSE-HINDS GMBH.
13 I A -pole up to 0 V I I A -pole up to V I Flange socket Coupler Dimension drawing Wiring diagram 0 X0 0 X0 -pole -pole Coupler -pole Flange socket -pole Dimensions in mm X. 0 X 0 X -pole ~ -pole 0 0 ~ Coupler -pole X. 0 0 ~ ~ X. X. Flange socket -pole X = fixing dimensions without L L L PE with L L L PE without L L L N PE with L L L N PE P + PE P + AUX + PE P + N + PE P + N+ AUX + PE.0 COOPER CROUSE-HINDS GMBH
14 I A -pole up to 0 V I I A -pole up to V I Protective canopy cap GHG R0 Accessories Mounting plates for wall sockets A Type Application Fixing method Order No. Size for wall mounting snapped on GHG R0 Size for trellis mounting snapped on GHG R0 Size for pipe mounting snapped on GHG R0 cap for plugs A Type A -pole/-pole A -pole Accessories for mounting plates Order No. GHG R000 GHG R000 Type OU Order No. Mounting set for pipes (Ø - 0 mm) for mounting plates with pipe fixing GHG R000 Please pay attention to that only order units (OU) according to the ordering details can be delivered. Protective canopy for mounting plate Type Application Order No. Size for mounting plate size, plugable GHG R0 Dimension drawing Mounting plate size for wall/trellis mounting Mounting plate size for pipe mounting Protective canopy size COOPER CROUSE-HINDS GMBH. Dimensions in mm
15 I A -/-pole Transformer plug I I with fuse I Transformer plug cap Technical data Ex-transformer plug accd. to IEC 00-/, up to V Marking to //EC II G Ex de IIC T EC-Type Examination Certificate PTB ATEX IECEx certification of conformity IECEx BKI IECEx type of protection Ex ed [ia] IIC T/T Permissible ambient temperature -0 C to + 0 C ) Rated voltage primary 0 V AC Rated voltage secondary V, V or V/0 V (AC) Frequency 0/0 Hz Power consumption max. VA Back up fuse, internal 0. A mt, replaceable Connecting terminals x - mm Insulation class I Degree of protection to EN 0 IP Glass-fibre reinforced polyester, polyamide Ordering details Voltage h Type Weight approx. Sec voltage Order No. A transformer plug -pole 00-0 V Transformer plug VA. kg V GHG V0000 Transformer plug VA. kg V GHG V00 A transformer plug -pole 0- V Transformer plug VA. kg V GHG V0000 Transformer plug VA. kg V GHG V00 Transformer plug VA. kg V GHG V0 Transformer plug VA. kg 0 V GHG V0 with fuse 00-0 V with fuse max.. A. kg GHG V0000 Accessories cap pole cap pole ) extended temperature range on request GHG 0 R000 GHG 0 R000. COOPER CROUSE-HINDS GMBH
16 I A -/-pole Transformer plug I I with fuse I Dimension drawing Transformer plug Ø Ø 0 Ø 0 Transformer plug COOPER CROUSE-HINDS GMBH. Dimensions in mm
17 I A - and -pole up to 0 V I Technical data Ex-plugs and receptacles accd. to IEC 00-/ Marking to //EC II G Ex de IIC T/T / II D Ex td A IP T0 C EC-Type Examination Certificate PTB 00 ATEX 0 IECEx certification of conformity IECEx BKI IECEx type of protection Ex ed IIC T Permissible ambient temperature -0 C to + 0 C ) Rated voltage 0 V (AC) Rated current A Frequency up to 00 Hz Rated making/rated breaking capacity AC- accd. EN 0- Ue 0 V / Ie A External back up fuse without therm. protection: A with therm. protection: 0 A gl (rated currrent A set to) Insulation class I Degree of protection accd. EN 0 IP Enclosure colour Black Cable glands/enclosure drilling x M0 Ø - mm, x M0 Ex-screw plug plastic or x M0 metal thread with Ex-screw plug plastic Connecting terminals x - mm / with cable lug x mm Glass-fibre reinforced polyester Cabel glands Ø - mm Connecting terminals x - mm / pin-cable lug ) x mm Polyamide ) extended temperature range on request. COOPER CROUSE-HINDS GMBH
18 I A - and -pole up to 0 V I Ordering details cap Voltage h Type Auxiliary contact Cable entries Weight approx. Order No. Type A -pole 00-0 V KU. kg GHG 0 R000 ME. kg GHG 0 R00 0. kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R000 Type A -pole 00-0 V KU. kg GHG 0 R V ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R000 Accessories cap for plugs Type OU Order No. cap -pole/-pole GHG R000 Pin cable lug mm GHG R000 Other voltage ranges and versions available on request. KU = x plastic cable glands M0 for Ø - mm, x M0 Ex-screw plug plastic KH = x plastic cable glands M0 for Ø - mm, x plastic cable glands M for Ø - mm, with ME = x metal thread M with Ex-screw plug plastic COOPER CROUSE-HINDS GMBH.
19 I A - and -pole up to 0 V I Dimension drawing Wiring diagram 00 X /-pole /-pole X = fixing dimensions Dimensions in mm Ø 0 0 X approx. without L L L PE with L L L PE without L L L N PE with L L L N PE P + PE P + AUX + PE P + N + PE P + N + AUX + PE -pole -pole. COOPER CROUSE-HINDS GMBH
20 I A - and -pole up to 0 V I Technical data Ex-plugs and receptacles accd. to IEC 00-/ Marking to //EC II G Ex de IIC T / II D Ex td A IP T0 C EC-Type Examination Certificate PTB 0 ATEX IECEx certification of conformity IECEx BKI IECEx type of protection Ex ed IIC T Permissible ambient temperature -0 C to + 0 C ) Rated voltage 0 V (AC) Rated current A (AC) Frequency up to 00 Hz Rated making/rated breaking capacity AC- accd. EN 0- Ue 0 V / Ie A External back up fuse without therm. protection: A with therm. protection: A gl (rated currrent A set to) Insulation class I Degree of protection accd. EN 0 IP Enclosure colour Black Cable glands/enclosure drilling x M Ø - mm, x M Ex-screw plug plastic or x M0 metal thread with Ex-screw plug plastic Connecting terminals x - 0 mm / with cable lug ) x 0 mm Glass-fibre reinforced polyester Cabel glands Ø - mm Connecting terminals x - mm / with pin cable lug ) x 0 mm Polyamide ) extended temperature range on request ) use only delivered cable lug COOPER CROUSE-HINDS GMBH.
21 I A - and -pole up to 0 V I cap Ordering details Voltage h Type Auxiliary contact Cable entries Weight approx. Order No. Type A -pole 00-0 V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R V KU. kg GHG 0 R000 ME. kg GHG 0 R00 yes KH. kg GHG 0 R00 0. kg GHG 0 R000 Type A -pole 00-0 V KU.0 kg GHG 0 R V ME. kg GHG 0 R00 yes KH. kg GHG 0 R00. kg GHG 0 R000 Accessories Type OU Order No. cap -pole/-pole GHG R000 Cable lug 0 mm GHG 0 R000 Other voltage ranges and versions available on request. KU = x plastic cable glands M0 for Ø - mm, x M0 Ex-screw plug plastic KH = x plastic cable glands M0 for Ø - mm, x plastic cable glands M for Ø - mm, with ME = x metal thread M with Ex-screw plug plastic. COOPER CROUSE-HINDS GMBH
22 I A - and -pole up to 0 V I Dimension drawing Wiring diagram X 0 X0 /-pole Ø 0 approx. 0 /-pole X = fixing dimensions without L L L PE with L L L PE without L L L N PE with L L L N PE P + PE P + AUX + PE P + N + PE P + N + AUX + PE -pole -pole COOPER CROUSE-HINDS GMBH. Dimensions in mm
23 I A -pole up to 0 V I Technical data Ex-plugs and receptacles, -pole Marking to //EC II G Ex e II T / II D Ex td A IP T0 C ) EC-Type Examination Certificate PTB 00 ATEX 0 Permissible ambient temperature -0 C to + 0 C Rated voltage 0 V AC Rated current A Frequency up to 00 Hz External back up fuse without therm. protection: A with therm. protection: A gl (rated current A set to) Insulation class I Degree of protection accd. EN 0 IP Enclosure colour Black Cable glands/enclosure drilling x M0 Ø - mm, x M metal thread with Ex-screw plugs plastic Connecting terminals x.0 -. mm Glass-fibre reinforced polyester Cabel glands Ø - mm Connecting terminals x.0 -. mm crimp or solder connection ) Polyamide ) See manufactuers declaration 0 for non conductive dusts ) Please use appropriate crimp tool.0 COOPER CROUSE-HINDS GMBH
24 I A -pole up to 0 V I Ordering details Type h Cable entry Weight Order No. Type A -pole h KU. kg GHG 0 R000 h ME. kg GHG 0 R00 h 0. kg GHG 0 R000 h KU. kg GHG 0 R000 h ME. kg GHG 0 R00 h 0. kg GHG 0 R000 h KU. kg GHG 0 R000 h ME. kg GHG 0 R00 h 0. kg GHG 0 R000 Type Application Fixing method Order No. Accessories cap -pole GHG 0 R000 Mounting plate size for wall mounting snapp on GHG R0 Mounting plate size for trellis mounting snapp on GHG R0 Mounting plate size for pipe mounting snapp on GHG R0 Socket bushes set = pcs. GHG 0 0 R0 pins set = pcs. GHG 0 0 R0 Ex-Crimping tool for sockets and pins GHG 0 R000 Dismanteling tool for sockets and pins GHG 0 R000 KU = x plastic cable glands M0 for Ø - mm ME = x metal thread M with Ex-screw plug plastic Dimension drawing Coding 0 X 0. ~ 0 0 X Ø0 -pole h h h Ø X = fixing dimensions Dimensions in mm COOPER CROUSE-HINDS GMBH.
25 I 0A -pole up to 00 V I Technical data Ex-plugs and receptacles, -pole Marking to //EC II G Ex ed IIC T/T / II D Ex td A IP T0 C ) EC-Type Examination Certificate PTB 00 ATEX 0 Permissible ambient temperature -0 C to + 0 C Rated voltage 00 V Rated current A (T) / 0 A (T) Frequency up to 00 Hz Rated making/rated breaking capacity AC- Ue 00 V / Ie A accd. EN 0- Ue 0 V / Ie A External back up fuse without therm. protection: A with therm. protection: A gl (rated currrent /0 A set to) Insulation class I Degree of protection accd. EN 0 IP Enclosure colour Black Cable glands/enclosure drilling x M0 Ø - mm, Ex screw plugs plastic or x M metal thread with Ex screw plugs plastic Connecting terminals x. - mm Glass-fibre reinforced polyester Cabel glands Ø - mm Connecting terminals x.0 -. mm crimped or soldered connection ) Polyamide ) See manufactuers declaration 0 for non conductive dusts ) Please use appropriate crimp tool. COOPER CROUSE-HINDS GMBH
26 I 0A -pole up to 00 V I Ordering details Type h Cable entry Weight Order No. Type 0 A -pole -pole h KU. kg GHG 0 R000 -pole h ME. kg GHG 0 R00 -pole h 0. kg GHG 00 R000 -pole + PE h KU. kg GHG 0 R000 -pole + PE h ME. kg GHG 0 R00 -pole + PE h 0. kg GHG 00 R00 Type Application Fixing method Order No. Accessories cap -pole GHG 0 R000 Mounting plate size for wall mounting snapp on GHG R0 Mounting plate size for trellis mounting snapp on GHG R0 Mounting plate size for pipe mounting snapp on GHG R0 Socket bushes set = pcs. GHG 0 0 R0 ins set = pcs. GHG 0 0 R0 Crimping tool for sockets and pins GHG 0 R000 Dismanteling tool for sockets and pins GHG 0 R000 Other voltage ranges and versions available on request. KU = x plastic cable glands M0 Ø - mm, x M0 with Ex-screw plug plastic ME = x metal thread M with Ex-screw plug plastic Fixing material and accessories see page. pp. Dimension drawing Wiring diagram 0 X 0. -pole 0 X L L L -pole + PE N PE h h -pole 0 0 Ø -pole Ø X = fixing dimensions Dimensions in mm COOPER CROUSE-HINDS GMBH.
A good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationUnused flameproof threads for cable glands have to be closed with certified plugs.
E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.
More informationInternational approvals.
E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More informationMain current switches >180 A are realized in metal enclosures. Internationally approved.
E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility
More informationI Ex-safety switches I
EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationInternationally approved.
E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - M A N U A L M O T O R S T A R T E R S Up to A Motors have to be protected against over loads, phase failures and overheating: CEAG's power circuit breaker and manual motor starter features phase-failure
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More information9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist
More informationI Ex-control stations I
Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination
More informationELECTRICAL CONNECTIVITY
ELECTRICAL CONNECTIVITY EXLINK -POLE/-POLE + PE. EXLINK ETHERNET/USB EXLINK -POLE+PE.. MULTI-PURPOSE TERMINAL PLUGS AND RECEPTACLES FOR ZONE 0 A.. PLUGS AND RECEPTACLES FOR ZONE A PLUGS AND RECEPTACLES
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationInstallation Accessories
Installation Accessories Elektrostatische Aufladung vermeiden. Nur mit feuchtem Tuch säubern. Evitez lez charges electrotetiques Nettoyer unkjuement avec un chifion humide. Avold electrostatic charge.
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More informationLeading the way in hazardous areas Features EATON
.2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected
More informationDust - an Explosive Risk
CEAG Products for Dust Ex-Applications Dust - an Explosive Risk Safe Solutions from Eaton's Crouse-Hinds Division One spark may be enough. What can happen in areas with dust? Dust explosions are more dangerous
More information11 Control Panels, Distribution Panels and Components
Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working
More informationApparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components
E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS ellb 20... 1-5 W Metallic design for Zone 1 and 21 The ellb 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive
More informationThe Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.
E X - T E R M I N A L E N C L O S U R E S Stainless Steel Version for Zone and Zone 2 The enclosure range is an ATEX certified enclosure / termination solution for category 2 (Zone) application with an
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationNew products Ex Equipment 2015
New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More informationPRE Series 63 Amp Plugs and Sockets Increased Safety
Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator sets Air conditionings Compressors
More informationOperating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom
Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom Page 1 of 9 Rev. A / 2008-06-18 Product group: Empty enclosure polykom Terminal enclosures polykom The basic safety and health
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationCEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1
CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de
More informationATX PRE Series 63 Amp Plugs and Sockets Increased Safety
ATX PRE Series 63 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - D D S T R B U T O N S with metal EJ enclosures for gases in explosion group B Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.
More information4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)
4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationEVZ Series (Small body) Explosion protected luminaire Operating Instructions
EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East
More informationATX PRE Series 125 Amp Plugs and Sockets Increased Safety
ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationPRE Series 125 Amp Plugs and Sockets Increased Safety
s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices
More informationEX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS
EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS 4 5 6 8 EX-CEILING LIGHT FITTINGS EX-PENDANT LIGHT FITTINGS 4.4 4.0 EX-FLOODLIGHTS EX-VESSEL LIGHT FITTING 4.8 4.46 0 ZONE / EX-PENDANT LIGHT FITTINGS
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected switchgear CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können GHG 981 Ex-Safety switch for zone 22 GRP, Stainless steel, and painted steel enclosures for harsh environments
More informationMechanical features. Spring-loaded elastic terminals: resist vibrations
DXN 20 A 32 A 63 A Explosive atmospheres as standard Compact & robust design Safe & easy operation DXN decontactors are designed for explosive atmospheres, with de protection mode. They comply with the
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationI Ex-e/Ex-i terminal box I
ID TAG label & bracket Door document holder opti. Security padlock Hasp opti. Technical data Marking accd. to 94/9/EC II G Ex e II / II D Ex td A1 IP66 Temperature class T6 up to +40 C / T5 up to +55 C
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx BAS 07.0033X http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/9e9052... Page 1 of 4 18/06/2008 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationEX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS
1 EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 2 ouse se-hin inds 20 08 - all righ ghts re serv rved C ou Co oper Cr 3 4 5 6 7 EX-CEILING LIGHT FITTINGS 5.41 8 EX-PENDANT LIGHT FITTINGS EX-FLOODLIGHTS
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationExplosion protected terminal boxes type, GHG 72.
1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationT 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators
T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationJunction box for EKL light
M EKL light Junction box Junction box for EKL light Features Chemical-resistant Temperature-resistant Flame-retardant Absolutely corrosion-proof Seawater-proof Description Polyester enclosures have proven
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationOperating Instructions
Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationSynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
SynergEX Panelboards Panelboards for Hazardous Locations Installation & Maintenance Information IF 1659 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CAUTION Read these operating instructions and all other
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationDirect-acting 3/2 way plunger valve
Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationPY, SPY; FSQC, FP; EPC; AP
Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester
More informationSurface thermocouple Model TC50
Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial
More informationPlugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety
PRE Series: 16 A Plugs and Sockets Increased Safety ELV: Extra Low Voltage Plug Wall Mounting Socket Mobile Socket Flush Socket 20/25 Vac 20/50 Vdc 40/50 Vac LV: Low Voltage Plug Wall Mounting Sockets
More informationTechnical Data. Dimensions
Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush
More informationellk/m 92 LED 400/800
Explosion-protected Linear LED Light Fitting for Zone 1 and 21 1.1 ellk/m 92 LED 400/800 Linear LED Ex-light fittings ellk/m 92 LED 400/800 / ellk 92 LED 400/800 CG-S/NIB (Zone 1, 2, 21, 22) The efficient
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationCable resistance thermometer Model TR40
Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building
More information