MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features

Size: px
Start display at page:

Download "MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features"

Transcription

1 Miniature Circuit Breakers S260, S270, S280, S290 S260 S290 MCBs Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized under standard UL 077 as supplemental protective devices. The S2 devices are current limiting, DIN rail mounted and can offer a good equivalent to fused systems. The S2 is available with application-specifi c trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to B, C, D, K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifi cations. Features Current limiting Fast breaking time (2. 3. msec) Unique bus connection system Wide range of accessories Available with variable depth handle mechanism Optional Z curve for SCR protection CE certified and marked DIN rail or front panel mounting Finger safe terminals Multi-function terminals Suitable for reverse feed UL 077 and CSA /480VAC and 0V versions Low Voltage Products & s. ABB Inc AC 600-3/03

2 General information Tripping curves 0, B 0, C 0, D AC AC AC , K 0, UC-K AC , Z 0, UC-Z AC Low Voltage Products & s AC 600-3/03 ABB Inc

3 General information Construction details (S280 shown) Electro-magnetic pro tec tion Thermal protection-bimetal Operating mechanism Tripping lever Upper terminal Operator Trip in di ca tor Space for iden ti fi ca tion marker Arc chamber Fixed contact Moving contact DIN rail holder Lower terminal Low Voltage Products & s. ABB Inc AC 600-3/03

4 S /480 VAC B UL 077 CSA C22.2 No. 23 VDE 064 IEC-898 Cable protection S26-B6, pole S262-B6, 2 pole S26-B6NA, P+N Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 6 S26-B6 $ 36 0 S26-B S26-B S26-B S26-B S26-B2 38 A S26-B S26-B40 42 S26-B S26-B S26-B6NA 62 0 S26-B0NA 62 3 S26-B3NA 62 6 S26-B6NA S26-B20NA 68 2 S26-B2NA 72 B S26-B32NA S26-B40NA 76 S26-BNA S26-B63NA 02 6 S262-B S262-B S262-B S262-B S262-B S262-B2 88 A S262-B S262-B40 98 S262-B 2 63 S262-B63 28 Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 6 S263-B6 $ 8 0 S263-B0 8 3 S263-B3 8 6 S263-B S263-B S263-B2 32 A S263-B S263-B40 8 S263-B S263-B S263-B6NA 2 0 S263-B0NA 2 3 S263-B3NA 2 6 S263-B6NA 2 20 S263-B20NA 62 2 S263-B2NA 68 B S263-B32NA S263-B40NA 84 S263-BNA S263-B63NA S264-B6 6 0 S264-B0 6 3 S264-B3 6 6 S264-B S264-B S264-B2 76 B S264-B S264-B40 96 S264-B S264-B63 26 S263-B6, 3 pole Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery 0, S264-B6, 4 pole S263-B6NA, 3P+N B AC Discount schedule CBB Low Voltage Products & s AC 600-3/03 ABB Inc

5 S /480 VAC C UL 077 CSA C NO. 23 VDE 064 IEC-898 Cable & equipment protection 0, S26-C, pole S262-C, 2 pole S26-CNA, P+N S263-C, 3 pole S264-C, 4 pole S263-CNA, 3P+N C Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S26-C0. $ 42 S26-C 42.6 S26-C S26-C S26-C S26-C S26-C S26-C S26-C0 42 A S26-C S26-C S26-C S26-C S26-C S26-C40 2 S26-C S26-C S26-C0.NA 84 S26-CNA 84.6 S26-C.6NA 84 2 S26-C2NA 84 3 S26-C3NA 84 4 S26-C4NA 84 6 S26-C6NA 84 8 S26-C8NA 84 0 S26-C0NA 84 B S26-C3NA 84 6 S26-C6NA S26-C20NA 84 2 S26-C2NA S26-C32NA S26-C40NA 96 S26-CNA 2 63 S26-C63NA S262-C0. 96 S262-C 96.6 S262-C S262-C S262-C S262-C S262-C S262-C S262-C0 96 A S262-C S262-C S262-C S262-C S262-C S262-C40 6 S262-C S262-C63 2 Rated Catalog List Delivery current number price class 0. S263-C0. $ 38 S263-C 38.6 S263-C S263-C S263-C S263-C S263-C S263-C S263-C S263-C S263-C S263-C S263-C S263-C S263-C40 74 S263-C S263-CS S263-C S263-C0.NA 200 S263-CNA S263-C.6NA S263-C2NA S263-C3NA S263-C4NA S263-C6NA S263-C8NA S263-C0NA S263-C3NA S263-C6NA S263-C20NA S263-C2NA S263-C32NA S263-C40NA 224 S263-CNA S263-C63NA S264-C0. 28 S264-C 28.6 S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C S264-C Sugg. order qty Wgt. oz. ( pc.) A 3 3. B B Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery AC Low Voltage Products & s Discount schedule CB.7 ABB Inc AC 600-3/03

6 S /480 VAC D UL 077 CSA C22.2 VDE 064 IEC-898 Cable & equipment protection S26-D0., pole S262-D, 2 pole Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S26-D0. $ 42 S26-D 42.6 S26-D S26-D S26-D S26-D S26-D S26-D S26-D0 42 A S26-D S26-D S26-D S26-D S26-D S26-D40 2 S26-D S26-D S262-D0. 96 S262-D 96.6 S262-D S262-D S262-D S262-D S262-D S262-D S262-D0 96 A S262-D S262-D S262-D S262-D S262-D S262-D40 6 S262-D S262-D63 2 Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S263-D0. $ 38 S263-D 38.6 S263-D S263-D S263-D S263-D S263-D S263-D8 38 A S263-D S263-D S263-D S263-D S263-D S263-D S263-D40 74 S263-D S263-D Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery S263-D63, 3 pole 0, D AC Discount schedule CB Low Voltage Products & s AC 600-3/03 ABB Inc

7 S /480 VAC K UL 077 CSA C NO. 23 VDE 064 IEC-898 Cable & equipment protection 0, S27-K0, pole S272-K0, 2 pole S27-K0NA, P+N S273-K0, 3 pole S274-K0, 4 pole S273-K0NA, 3P+N K AC Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S27-K0. $ 42 S27-K 42.6 S27-K S27-K S27-K S27-K4 42 S27-KS 42 6 S27-K S27-K S27-K S27-K3 42 A 0 4. S27-KS 42 6 S27-K S27-K S27-K S27-KS S27-K S27-K40 2 S27-K S27-KS S27-K S27-K0.NA 84 S27-KNA 84.6 S27-K.6NA 84 2 S27-K2NA 84 3 S27-K3NA 84 4 S27-K4NA 84 6 S27-K6NA 84 8 S27-K8NA 84 0 S27-K0NA 84 B S27-K3NA 84 6 S27-K6NA S27-K20NA 84 2 S27-K2NA S27-K32NA S27-K40NA 96 S27-KNA 2 63 S27-K63NA S272-K0. 96 S272-K 96.6 S272-K S272-K S272-K S272-K4 96 S272-KS 96 6 S272-K S272-K S272-K0 96 A S272-K3 96 S272-KS 96 6 S272-K S272-K S272-K S272-KS S272-K S272-K40 6 S272-K S272-KS S272-K63 2 Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S273-K0. $ 38 S273-K 38.6 S273-K S273-K S273-K S273-K4 38 S273-KS 38 6 S273-K S273-K S273-K S273-K3 38 A 3 3. S273-KS 38 6 S273-K S273-K S273-K S273-KS S273-K S273-K40 74 S273-K S273-KS S273-K S273-K0.NA 200 S273-KNA S273-K.6NA S273-K2NA S273-K3NA S273-K4NA S273-K6NA S273-K8NA S273-K0NA 200 B S273-K3NA S273-K6NA S273-K20NA S273-K2NA S273-K32NA S273-K40NA 224 S273-KNA S273-K63NA S274-K0. 28 S274-K 28.6 S274-K S274-K S274-K S274-K S274-K S274-K8 28 B S274-K S274-K S274-K S274-K S274-K S274-K S274-K S274-K S274-K Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery KS is for standard U.S. size. Low Voltage Products & s Discount schedule CB.9 ABB Inc AC 600-3/03

8 S /480 VAC K UL 077 CSA C NO. 23 VDE 0660 Cable & equipment protection S28-K6, pole S282-K, 2 pole S283-K63, 3 pole Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0.2 S28-K0.2 $ S28-K S28-K S28-K0.7 4 S28-K 4.6 S28-K S28-K2 4 3 S28-K3 4 4 S28-K4 4 6 S28-K6 4 8 S28-K8 4 A S28-K0 4 3 S28-K3 4 6 S28-K S28-K S28-K S28-K S28-K40 64 S28-K S28-K S282-K S282-K S282-K S282-K S282-K 28.6 S282-K S282-K S282-K S282-K S282-K6 28 A S282-K S282-K S282-K S282-K S282-K S282-K S282-K S282-K40 34 S282-K S282-K63 82 Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0.2 S283-K0.2 $ S283-K S283-K S283-K S283-K 94.6 S283-K S283-K S283-K S283-K S283-K6 94 A S283-K S283-K S283-K S283-K S283-K S283-K S283-K S283-K40 2 S283-K S283-K Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery 0, K AC Discount schedule CB7 Low Voltage Products & s AC 600-3/03 ABB Inc

9 S280 (W) for use with ring tongue terminal connectors 277/480 VAC K UL 077 CSA C NO. 23 VDE 0660 Cable & equipment protection S28-K6W, pole S282-KW, 2 pole S283-K63W, 3 pole Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0.2 S28-K0.2W $ S28-K0.3W 4 0. S28-K0.W S28-K0.7W 4 S28-KW 4.6 S28-K.6W 4 2 S28-K2W 4 3 S28-K3W 4 4 S28-K4W 4 6 S28-K6W 4 8 S28-K8W 4 B S28-K0W 4 3 S28-K3W 4 6 S28-K6W 4 20 S28-K20W 4 2 S28-K2W 6 32 S28-K32W 8 40 S28-K40W 64 S28-KW S28-K63W S282-K0.2W S282-K0.3W S282-K0.W S282-K0.7W 28 S282-KW 28.6 S282-K.6W 28 2 S282-K2W 28 3 S282-K3W 28 4 S282-K4W 28 6 S282-K6W 28 B S282-K8W 28 0 S282-K0W 28 3 S282-K3W 28 6 S282-K6W S282-K20W 28 2 S282-K2W S282-K32W S282-K40W 34 S282-KW S282-K63W 82 Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0.2 S283-K0.2W $ S283-K0.3W S283-K0.W S283-K0.7W 94 S283-KW 94.6 S283-K.6W 94 2 S283-K2W 94 3 S283-K3W 94 4 S283-K4W 94 6 S283-K6W 94 B S283-K8W 94 0 S283-K0W 94 3 S283-K3W 94 6 S283-K6W S283-K20W 94 2 S283-K2W S283-K32W S283-K40W 2 S283-KW S283-K63W 280 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery Screws (must be ordered separately!) Item Catalog List number price 2 K PKG of 20 screws S2-SCR No charge 0, AC ➀ For use with ring tongue or cable terminals only. Cannot be used with busbar system. 2 No charge when ordered with the S280(W). Low Voltage Products & s Discount schedule CB7. ABB Inc AC 600-3/03

10 S280UC 0 V K UL 077 VDE 0660 CSA 22.2 No. 23 Cable and Equip ment Protection S28UC-K2, pole S282UC-K8, 2 pole S283UC-K6, 3 pole Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0.2 S28UC-K0.2 $ S28UC-K S28UC-K S28UC-K S28UC-K 04.6 S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K6 04 B S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K40 6 S28UC-K S28UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K4 242 B S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K Rated Catalog List Delivery current number price class 0.2 S283UC-K0.2 $ S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K63 34 Sugg. order qty Wgt. oz. ( pc.) B Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery Direct current applications The S280UC differs from standard miniature circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown below. Maximum voltage between leads 0, UC-K 2V Single Pole S28UC L- L+ 0V Two Pole S282UC L- L- L+ L LOAD - + LOAD LOAD Termination points are marked on all UC type MCBs, points one () and four (4) are negative and points two (2) and three (3) are positive. Four pole breakers are also available for voltage reversal applications..2 Discount schedule CB7 Low Voltage Products & s AC 600-3/03 ABB Inc

11 S280 & S280UC 277/480VAC & 0V Z UL 077 VDE 0660 CSA 22.2 No. 23 Fast trip characteristic S28-Z6, pole S282-Z32, 2 pole S283-Z32, 3 pole 277/480 VAC 0 V Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S28-Z0. $ 70 S28-Z 70.6 S28-Z S28-Z S28-Z S28-Z S28-Z S28-Z8 70 B S28-Z S28-Z S28-Z S28-Z S28-Z S28-Z40 78 S28-Z S28-Z S282-Z0. 62 S282-Z 62.6 S282-Z S282-Z S282-Z S282-Z S282-Z S282-Z8 62 B S282-Z S282-Z S282-Z S282-Z S282-Z S282-Z40 76 S282-Z S282-Z S283-Z S283-Z S283-Z S283-Z S283-Z S283-Z S283-Z S283-Z8 244 B S283-Z S283-Z S283-Z S283-Z S283-Z S283-Z S283-Z S283-Z Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S28UC-Z0. $ 68 S28UC-Z 68.6 S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z0 68 B S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z40 88 S28UC-Z S28UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z0 390 B S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S283UC-Z0. 94 S283UC-Z 94.6 S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z8 94 B S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z40 67 S283UC-Z S283UC-Z63 8 0, UC-Z 0, Z Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery AC Low Voltage Products & s Discount schedule CB7.3 ABB Inc AC 600-3/03

12 S /480 VAC C VDE 0660 Cable and equipment protection S29-C VAC Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 80 S29-C80 $ S29-C00 4 B S29-C S292-C S292-C B S292-C S293-C S293-C00 48 B S293-C S294-C S294-C00 76 B S294-C2 948 S290-H Auxiliary contact S290-H 72 B.7 Bell alarm S290-S 2 B.7 Shunt trip S290-A 4 B 6.2 For fi eld mounting, left side, 0V 4VAC S290-A2 4 B 6.2 For fi eld mounting, left side, 24 48V Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery 0, C AC Discount schedule CB9 Low Voltage Products & s AC 600-3/03 ABB Inc

13 Accessories Busbars S260, S270, S280 Phase L... L Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) SZ-KS/2 $ SZ-KS/6 36 A SZ-KS2/ SZ-VB Uninsulated copper bar mounts fl ush with bottom edge of circuit breakers. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. 2 Phase Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) L L PSB-END3 SZ-PSB4N $ PSB-END3 SZ-PSB6N 22 A PSB-3UL Insulated busbar assembly contains 2 separate circuits for use with, +N or 2 pole MCBs. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. L L2 L L Phase Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) 2 23 PSB-3UL $ PSB-END6 SZ-PSB4N 30 A PSB-END6 SZ-PSB2N L L2 L3 Insulated busbar assembly contains 3 separate circuits for use with or 3 pole MCBs. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. L L2 L3 L L2 L Phase Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) PSB-END4 SZ-PSB62N $ 204 A PSB-END4 SZ-PSB64N L L2 L3 L4 L L2 L3 L4... L L2 L3 L4 Insulated busbar assembly contains 4 separate circuits for use with 3+N or 4 pole MCBs. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery Low Voltage Products & s Discount schedule CB8. ABB Inc AC 600-3/03

14 Accessories Busbars S260, S270, S280 Phase with auxiliary L Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) PSB-END3 SZ-KS3/39N $ A PSB-END3 SZ-KS4/39N 6 A 0. Insulated busbar assemblty for use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. L L L... 3 Phase for pole MCB's with auxillary L L2 L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) PSB-END3 SZ-PSB46N $ 24 B PSB-END3 SZ-PSB48N 8 B 22. Insulated busbar assembly contains 3 separate circuits for use with pole MCBs. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. L L2 L Phase with auxillary Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) SZ-PSB92N 74 B 23.2 Insulated busbar assembly contains 2 separate circuits for use with or 2 pole MCBs. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. L L2 L L2 L L2 L L Phase with auxillary L L2 L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) PSB-END3 SZ-PSBN $ 24 B PSB-END3 SZ-PSB2N 8 A 22.6 Insulated busbar assembly contains 3 separate circuits for use with or 3 pole MCBs. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. L L2 L3 L L2 L3... Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery.6 Discount schedule CB8 Low Voltage Products & s AC 600-3/03 ABB Inc

15 Accessories Busbars S260, S270, S280 3 Phase L L2 L3 L L2 L3... L L2 L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) PSB-END3 SZ-PSB23N A PSB-END3 SZ-PSB24N Insulated busbar assembly contains 3 separate circuits for use with, 2+N or 3 pole MCBs. For use on line side (top) of S260 and S270 MCBs. Phase L... L Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Insulated busbar assembly contains circuit for use with pole MCBs. For use on line side (top) of S260 and S270 MCBs. Weight (ozs) SZ-KS6/2N $ 3 A SZ-KS6/6N Phase + N, for use with 2 pole MCB's on 3 phase / 4W system N L L2 L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) PSB-END4 SZ-PSB8N $ 98 B PSB-END4 SZ-PSB60N 238 A 30.8 Insulated busbar assembly contains 4 separate circuits for use with +N or 2 pole MCBs. For use on load side (bottom) of S260, S270, S280 and line side (top) of S280 MCBs. L N L2 N L3 N L N L2... MCB Busbar accessories Busbar mounted terminal block p/n: SZ-ESK2 -pole Busbar End Caps Bus tooth covers p/n: SZ-BSK -poles Catalog List Delivery Suggested Weight Description number price class order qty. ounce qty. (2 pc.) PSB-END3 Busbar end caps PSB-END4 PSB-END $ 2 A 0 PSB-END6 Busbar tooth covers (shrouds unused portion of busbar) SZ-BSK 4 A 0 Busbar mounted terminal block, pole, for use on all busbars. SZ-ESK2 0 A.0 Wire size: AWG to 2 AWG Busbar mounted terminal block, pole, for use on all busbars. SZ-ESK 0 A.0 Wire size: AWG to 4 AWG. NOTE ALL BUSBARS MAY BE CENTER FED IN OR- DER TO DOUBLE THE AMPACITY RATING Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery Low Voltage Products & s Discount schedule CB8.7 ABB Inc AC 600-3/03

16 Accessories S260, S270 & S280 S2-H Auxiliary contacts Electrical Catalog List Delivery Suggested Wgt. oz. accessories number price class order quantities ( pc.) For fi eld mounting: left side N.O./ N.C. S2-H $ 36 2 N.O. S2-H N.C. S2-H02 36 N.O./ 2 N.C. S2-H2 4 2 N.O./ N.C. S2-H2 4 2 N.O./ N.C. (low voltage) S2-H2KL 60 A.4 The S2-H auxiliary switch can be fi eld mounted to any S260, S270 or S280 series breaker. The auxiliary contacts will signal whether the breaker is in the ON or OFF position. The contacts are rated 6A/240 VAC and.a/0 V. Minimum operating voltage is 2 VAC/V. Wire size: 8 AWG to 6 AWG. Bell alarm For fi eld mounting, left side S2-S 48 A.4 The S2-S bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. The contact is rated 6A/240 VAC and.a/0 V. Minimum operating voltage is 2 VAC/V. S2-A Bell alarm with auxiliary contact For fi eld mounting, left side S2-S/H 8 A.4 The S2-S/H bell alarm with auxiliary contact device combines one set of bell alarm contacts with one set of auxiliary contacts (N.O.). Shunt trip For fi eld mounting, left side 2-60 VAC (2-60V) S2-A 0-4 VAC (0-2 V) S2-A2 38 A.2 For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Shunt trips are available depending on control system voltage (2-4 VAC/V). S2-BM Undervoltage release For fi eld mounting, left or right side 2 V S2-BM 24 VAC/V S2-BM2 48 VAC/V S2-BM3 0 VAC/V S2-BM4 220 VAC/V S2-BM 380 VAC S2-BM6 26 A.2 When control voltage drops below approximately % of rated voltage, the S2-BM opens the breaker. The breaker can not be operated unless proper control voltage is fi rst applied to the UVR coil. Similar in size and mounting to the shunt trip accessory; can be left or right side mounted. S2-S Hand operated neutral disconnect For fi eld mounting, right side, 40A max. S2-NT 27 A.4 Wire range: -8 AWG. Must be turned off manually. Not UL Listed. S2-NT is only /2 pole width. Factory mounting All accessories can be easily mounted in the fi eld. For factory mounting of any accessory devices, add $30 list to total price per breaker. To create complete catalog number, take suffi x of accessory device following S2- and add suffi x to end of breaker part number. Multiple suffi xes must be added in alphabetical order. Example: S272-K20A $ 264 (2 pole, 20A breaker with type A shunt trip) $96 + $38 + factory $30 = $264 S272-K20A2H $ 300 (2 pole, 20A breaker with type A2 shunt trip and H aux. contacts) S272- $96 + $38 + $36 + factory $30 = $300 S2-S/H Auxiliary contacts and shunt trips may be mounted in combination. Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery S2-NT NOTE: Above accesssories are for use with types S260, S270 and S280 breakers only..8 Discount schedule CB8 Low Voltage Products & s AC 600-3/03 ABB Inc

17 Accessories S260, S270, S280 S0-ME2 Front mounting kit Electrical Catalog List Delivery Suggested Wgt. oz. accessories number price class order quantities ( pc.) For 2 poles S0-ME $ For 2 poles S0-ME2 70 A 2.9 For 2 0 poles S0-ME Optional rear terminals S0-K 6. Includes fl ange, mounting rail and hardware. Front mounting clip For 4 poles MB-CL 3 A 2 Simple mounting clip for up to four module mounting. Front mounting bracket For 3 poles MB-3PD 3 A 2. For fl ush mounting of three pole MCBs: includes hardware. MB-CL Locking device Adaptor only SA 9 A Padlock only w/ 2 keys SA Allows breaker to be locked in ON or OFF position. Labeling accessory sheet = 00 blank labels sheet = 00 numbered labels STL-ST 74 A Snaps into rail indent on front of MCB Label holder & labels includes 00 label carriers. MB-3PD SA Enclosure, IP For 4 modules For 6 modules A 0.8 For 0 modules For 20 modules Molded plastic complete with mounting rail and knock-outs for cable entries. Blanking plates Single pole (set of 0) BP-P 6 A Twelve pole (snap-off, set of ) BP-2P 7 SA2 Terminal cover enclosure, IP40 For 2 modules For 4 modules B 2.8 For 6 modules For 8 modules For additional protection against accidental contact. Includes integrated mounting rail. Handle mechanism For use with 2, 3 and 4 pole S2 MCBs and disconnect switch handles with mm shaft. Mounting rail RHS2-M 76 A 9.2 Universal mounting SMR-39 2 A 8 3mm DIN rails are available in 39-inch strips ( meter). Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery Low Voltage Products & s Discount schedule CB8.9 ABB Inc AC 600-3/03

18 Accessories S260, S270, S280 Posidrive tools Screwdriver, # SD-PZ $ 40 A 4 Screwdriver, #2 SD-PZ2 40 A 4 Bit, # BIT-PZ 4 A 4 Bit, #2 BIT-PZ2 4 A 4 Connection terminals Electrical Catalog List Delivery Suggested Wgt. oz. accessories number price class order quantities ( pc.) Cross section Type Catalog List Delivery Suggested Wgt. oz. mm 2 number number price class order quantities ( pc.) 2AWG (3mm 2 ) Fork SZ-AS7 0 A /0 (mm 2 ) Fork SZ-AS78 0 A /0 (mm 2 ) Pin SZ-AST2 A 0 0. /0 (mm 2 ) Pin SZ-AST A Discount schedule CB8 Low Voltage Products & s AC 600-3/03 ABB Inc

19 Technical data Mounting and operating instructions Mounting MCB Removing MCB Mounting Universal mounting position using snap-on mounting to standard 3x7.mm DIN rail. Miniature circuit breakers (MCBs) can also be mount ed to front of door using a panel cut-out with breaker handle pro trud ing through panel opening for external operation. Special front mount ing kit type ME is avail able (see page 2.2). Connection Terminals are suitable for solid or fl exible conductors from 8 to 4 AWG (0.7 to 2mm 2 ) with no busbar connected. When max i mum busbar size of 36 mm 2 is used, maximum cable is 6 AWG (6 mm 2 ). Maximum tightening torque of 7. in-lb (2 Nm) for line/load terminals and 4. in-lb (0.Nm) for ac ces so ry device terminals. Operation MCBs are switched on by moving the handle to the upper po si tion. Stamped onto the handle switch, a I is visible confi rming that the breaker is closed. The MCBs are trip-free, if the handle is being forced to the ON position, the breaker will still trip under fault conditions. The O marking indicates that the breaker is in the OFF position. The MCB is now open and the load is disconnected from line power. When a breaker has tripped, the MCB handle should fi rst be set to the full OFF position to make certain the trip mechanism has been reset. Once the fault has been determined and cleared the MCB can again be switched ON. Maintenance ABB miniature circuit breakers require no special maintenance; only normal electrical system maintenance pro ce dures are required. Possible mounting arrangements of MCB accessories H S S/H MCB NT H S S/H A BM MCB A BM MCB BM Auxiliary switch/bell alarm neutral disconnect Auxiliary switch Shunt trip or undervoltage release mounted with auxiliary switch Shunt trip and/or undervoltage release Set MCB to OFF position and mount Set breaker to ON position Break out opening on side of MCB auxiliary switch to side of breaker Attach with spring clamps Bell alarm with auxiliary contact Set MCB to OFF position, insert metal pin as Break out opening on side of MCB noted above with arrow and mount device to Set breaker to ON position and remove seal side of MCB Attach with spring clamps Shunt trip and undervoltage release Remove seal Add shunt trip to MCB Attach with spring clamps Low Voltage Products & s.2 ABB Inc AC 600-3/03

20 Technical data Busbars & connectors Connection methods Dual function terminals provided in open position for connection to busbars. Pressing on screw head opens box terminal for cable insertion. Only the lower terminal is dual func tion. Terminals allow for con nec tion of cable 8-4 AWG. Conductors of different sizes may also be used in same terminal. Up to fi ve conductors, 6 AWG each, can be safely connected per terminal. Lower terminals can be bussed together with single phase or multi-phase busbars as shown. Upper ter mi nals can also be busbar con nect ed. Lower terminal can also be bussed with solid round con duc tor. Cables can be connected to box terminals in addition to busbar con nec tions on lower, dual function terminals..22 Low Voltage Products & s AC 600-3/03 ABB Inc

21 Technical data S260, S270, & S280 Item S260-B S260-C, -D S270-K S280-K Approvals: UL CSA C22.2 No.23 C22.2 No. 23 C22.2 No. 23 VDE 064, IEC 898, , , , 947 No. of poles:,2,3,4 +N,3+N,2,3,2,3,4, +N,3+N,2,3,4,+N,3+N Tripping characteristic: B C,D K K Rated currents: 6 to 63A 0. to 63A 0. to 63A 0.2 to 63A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 20VAC 0kA 0kA 0kA 0kA for A 6kA for -63A 240VAC 6kA 0kA 6kA 0kA 6kA 0kA 0kA for A 0kA for A 6kA for -63A 6kA for 40-63A 277VAC 6kA 6kA 6kA 0kA for A 277/480 VAC 6kA 6kA 6kA 0kA 60V 0kA 0kA 0kA 0kA 0kA 0kA 2V 0kA 0kA 0kA Frequency: /60Hz (See below) /60Hz (see below) /60Hz (see below) /60Hz (see below) Rated voltage IEC single pole 240/4VAC 240/4VAC 240/4VAC 240/4VAC 60V 60V 60V 60V IEC multi-pole 4VAC 4VAC 4VAC 4VAC 0V 0V 0V 0V Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm Mounting position: optional optional optional optional Standard mounting: 3mm DIN rail 3mm DIN rail 3mm DIN rail 3mm DIN rail Main and shunt trip terminals: Wire size 6-40A 8-4 AWG 0.-40A 8-4 AWG 0.-40A 8-4 AWG A 8-4 AWG A & above 8-2 AWG A & above 8-2 AWG A & above 8-2 AWG A & above 8-2 AWG Torque 7. in-lbs. 7. in-lbs. 7. in-lbs. 7. in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4. in-lbs. 4. in-lbs. 4. in-lbs. 4. in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -2 C to + C -2 C to + C -2 C to + C -2 C to + C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: g, 20 cycles, Hz, Hz g, 20 cycles, Hz, Hz g, 20 cycles, Hz, Hz g, 20 cycles, Hz, 0.8 ~ I 0.8 ~ I 0.8 ~ I 0.8 ~ I n Disconnecting neutral rating: 6kA switching 6kA switching 6kA switching Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for /60Hz ap pli ca tions. For frequencies other than /60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz Approx. factor..2.. Thermal tripping is independent of frequency. Available for purchase. See page.9. Low Voltage Products & s.23 ABB Inc AC 600-3/03

22 Technical data S280, S280UC, S290 Item S280UC-K S280-Z S280UC-Z S290-C Approvals: UL CSA VDE IEC 898, , , No. of poles:,2,3,2,3,4,2,3,2,3,4 Tripping characteristic: K Z Z C Rated currents: 0.2 to 63A 0. to 63A 0. to 63A 80 to 2A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 20VAC 6kA for A 0kA for A 6kA for A ka for -63A 6kA for -63A ka for -63A 240VAC 6kA for A 6kA for A 0kA for A 0kA for A 6kA for A 6kA for A ka for -63A ka for -63A 6kA for -63A 6kA for 40-63A ka for -63A ka for -63A 277VAC 4.kA for A 0kA for A 4.kA for A ka for -63A 6kA for -63A ka for -63A 277/480 VAC 4.kA for A 0kA 4.kA for A ka for -63A ka for -63A 60V 0kA 0kA 0kA 0kA 2V 0kA 0kA 0kA 0kA 2V 4.kA 4.kA 4.kA 4.kA 0V 4.kA 4.kA Frequency: /60Hz (see below) /60 Hz (see below) /60Hz (see below) /60Hz (see below) Rated voltage IEC single pole 240/4VAC 240/4VAC 240/4VAC 230/440VAC 220V 60V 220V 60V IEC multi-pole 4VAC 4VAC 4VAC 440VAC 440V 0V 440V 0V Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 70mm Mounting position: optional optional optional optional Standard mounting: 3mm DIN rail 3mm DIN rail 3mm DIN-rail 3mm DIN-rail Main and shunt trip terminals: Wire size A 8-4 AWG 0.-40A 8-4 AWG 0.-40A 8-4 AWG 80-2A -/0 AWG A & above 8-2 AWG A & above 8-2 AWG A & above 8-2 AWG Torque 7. in-lbs. 7. in-lbs. 7. in-lbs. 7. in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4. in-lbs. 4. in-lbs. 4. in-lbs. 4. in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -2 C to + C -2 C to + C -2 C to + C - C to +4 C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: g, 20 cycles, Hz, Hz g, 20 cycles, Hz, Hz g, 20 cycles, Hz, Hz 60m/s 2, at ~ I 0.8 ~ I 0.8 ~ I n Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for /60Hz ap pli ca tions. For frequencies other than /60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz Approx. factor..2.. Thermal tripping is independent of frequency..24 Low Voltage Products & s AC 600-3/03 ABB Inc

23 Technical data Let-through values Description All ABB miniature circuit breakers substantially reduce the maximum letthrough current from the peak avail able short circuit current. I K - RMS current of fault I D - Max let-through of MCB V n - voltage V B - Arc voltage of MCB t k - Breaking time of MCB k 2 u B I D Let-through values I 2 t t k Sine half wave Hz = T/2 = 0ms U n S260-B S270-K S280-K For other curves, please contact ABB Control. Version I 2 t I Peak S260B TD9980 S260C TD998 S260D TD9982 S270K TD9972 TD99 S280K TD9978 S280Z TD9979 S290C TD998 Version Amps Time-current trip S260B 6-63 TD972 S270K TD TD TD9707 S280K TD TD TD970 S280Z TD97 Low Voltage Products & s.2 ABB Inc AC 600-3/03

24 Technical data Temperature derating factors Terminal markings Type B, C, D Type K, Z Current carrying capacity of type B, C, D, K and Z thermal trip characteristics as a function of ambient tem per a ture. Terminal markings Input optional from top or bottom N 3 7N N N Pole 2Pole 3Pole Pole&NA 3Pole&NA D 3 2 BELL ALARM 9 AUX SW C I C2 U D2 H S/H A /A2 BM.26 Low Voltage Products & s AC 600-3/03 ABB Inc

25 Technical data Breaker resistance values & wire size comparison Miniature circuit breaker resistance values Ampere Milliohms rating S260-B S270-K S280-K S280-Z Comparison of IEC and AWG wire sizes mm AWG (mm ) Amps / UL Amps / IEC (.3) 0. 2 (2.) (3.3) (.3) (8.4) 0 6 (3.3) (2.2) (26.7) 00 2 (33.6) 3 Ampacities for AWG wire are based on copper cable rated 7 C, except for 6AWG which is based on 60 C wire. Taken from UL8 Table 2.2. Consult applicable standards for futher detail and information. Low Voltage Products & s.27 ABB Inc AC 600-3/03

26 Approximate dimensions S260, S270, S280, S Inches [Millimeters] S260 & S (90.0) 2.72 (69.0) 0.69 (7.) 0.69 (7.) 0.69 (7.) CL 2.07 (2.) 0.69 (7.) UPPER TERM..77 (4.0) LOWER TERM. CL 2.9 (74.9) 0.8 (.8) CL 2.68 (68.0) CL.46 (37.).98 (.2) S (90.0) 2.72 (69.0) 0.69 (7.) 0.69 (7.) 0.69 (7.) CL 2.07 (2.) 0.69 (7.) UPPER TERM..77 (4.0) LOWER TERM. CL 2.9 (74.9) 0.8 (.8) CL 2.68 (68.0).46 (37.).98 (.2) S290 Accessories mount to right side of MCB only A, -A2 Shunt trip -H Auxiliary switch -S Bell alarm.28 Low Voltage Products & s AC 600-3/03 ABB Inc

27 Inches [Millimeters] Approximate dimensions Accessories Accessories Left side mtd Left or right side mtd H/S Bell alarm H_ Auxiliary switch A_ Shunt trip 3-pole MCB U_ Undervoltage trip MB-CL Front mounting clip.77 4 D C.L C.L MB-3PD Front mounting bracket (3P).43(2P).87 C L C L BREAKER CUT OUT 0.74(P) BKT. MT. HOLES 0.2 DIA. TYP 2 RHS2-M Handle mechanism CL CL Low Voltage Products & s.29 ABB Inc AC 600-3/03

28 Approximate dimensions Accessories Inches [Millimeters] Low Voltage Products & s AC 600-3/03 ABB Inc

29 Cross-reference Older Suggested Physical Electrical version replacement comparison comparison series S60L S260B Same pole spacing Same trip char ac ter is tic as L S60K S270K Same pole spacing Same trip char ac ter is tic as K S270 is 6kA IC S20L S260B Same pole spacing Same trip char ac ter is tic as L S260B is 6kA IC S20K S280K Same pole spacing Same trip char ac ter is tic as K S280K is 6kA IC S20Z S280Z Same pole spacing Same trip char ac ter is tic as Z S2L S260B Same pole spacing Same trip char ac ter is tic as L S20-UCK S280UC-K Same pole spacing Same trip char ac ter is tic as K S20-UCZ S280UC-Z Same pole spacing Same trip char ac ter is tic as Z S220-K S0-K Different pole spacing Same trip char ac ter is tic as K S230-B S260-B Same pole spacing Same trip char ac ter is tic as B Many older styles of ABB miniature circuit breakers have been replaced by new and improved versions. Many of these newer styles can be directly interchanged, both electrically and physically, with the older version. There are also many international styles of ABB circuit breakers which are not normal stock items and may be interchanged with stocked ABB versions. Note: MCB types S260/270 and S280 can be raised to the same height as older style S20 series MCBs through the use of a height adjuster (SZ-ES68/83; $ 30 list per 20). The height adjustor snaps onto the DIN rail and raises the height of com po nents 68mm to match that of the S20 series (83mm). Low Voltage Products & s.3 ABB Inc AC 600-3/03

30 Notes.32 Low Voltage Products & s AC 600-3/03 ABB Inc

31 Miniature Circuit Breakers S280U Compact branch circuit protective MCCB UL 489 Listed as branch circuit protective MCCB S280U MCBs Description UL 489 Listed for branch circuit protection! ABB is pleased to announce our new S280U series of miniature circuit breakers -- all the functionality of molded case circuit breakers plus all the great features of miniature circuit breakers: Branch circuit protective device Compact DIN rail mount Current limiting, 2, & 3 pole Ring-tongue terminal option The ABB S280U series miniature circuit breakers are true UL489 listed compact molded case circuit breakers. They are suitable, per UL and the NEC, as branch circuit protective devices for circuits feeding either resistive or inductive loads including cables, duplex plugs, lighting, motors, transformers, and other loads where signifi cant levels of inrush current are possible. They can be applied in applications up to 240 VAC and are available in a wide range of current ratings, from 0.2 up to 63 amps. Both European and North American standard current sizes are available. Low Voltage Products & s.33 ABB Inc AC 600-3/03

32 S280U Compact branch circuit protective MCCB S28U-K S28UX-K S282UX-K0 S283UX-K20 S28U-K_ S28UX-K_ S282UX-K_ S283UX-K_ -pole -pole 2-pole 3-pole Catalog List Box Catalog List Box Catalog List Box Catalog List Box number price Qty. number price Qty number price Qty number price Qty S28U-K0.2 $ 70 0 S28UX-K0.2 $ 70 6 S282UX-K0.2 $ 62 3 S283UX-K0.2 $ S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K 70 0 S28UX-K 70 6 S282UX-K 62 3 S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K 70 0 S28UX-K 70 6 S282UX-K 62 3 S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K 70 0 S28UX-K 70 6 S282UX-K 62 3 S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K 88 0 S28UX-K 88 6 S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K S28U-K S28UX-K S282UX-K S283UX-K Ring tongue terminal compatible..34 Discount schedule CB2 Low Voltage Products & s AC 600-3/03 ABB Inc

33 Technical data Approval UL489 UL File No. E22323 CE Marked Voltage 240 VAC, 2, and 3 pole Current ratings (A) 0.2, 0.3, 0., 0.7,,.6, 2, 3, 4,, 6, 8, 0, 3,, 6, 20, 2, 30, 32, 40,, 60, 63 Interrupting capacity (A) 0.2-2A: 240VAC,, 2, and 3 pole 30-63A: 240VAC,, 2, and 3 pole Frequency /60 Hz Terminals Dual function, up to (2) stripped wires plus fork style crimp terminals. Ring tongue terminal compatible Terminal range () 8-4 AWG or (2) 8-8 AWG (copper wire only) or () 8-4 AWG + () 8 - AWG Solid or stranded wire, or mixed Terminal torque 8 lb.in., combination fl at blade / No. 2 posi-drive screw Service life 20,000 operations at rated load HACR rating Heating, Air-Conditioning, and Refrigeration rating (marked on front of breaker) Ambient temperature 2 C Thermal release (A) x MCB amperage rating Magnetic release 8 -. x MCB amperage rating Operational temperature -2 to + C range.0.3 0, C. B. S 28 UX LISTED E22323 K2A ~240 V /60 Hz ka 2 Time in 0 UL489 HACR Current in multiples of breaker ampere rating Time Current trip curve Thermal release threshold:.0 -.3X Magnetic release threshold: 8 -.X Ambient calibration temperature: 2 C S28UX-K2 Scale : LISTED Low Voltage Products & s.3 ABB Inc AC 600-3/03

34 Approximate dimensions DIN RAIL S28U-K_ S28UX-K_ S282UX-K_ S283UX-K_ Discount schedule CB0 Low Voltage Products & s AC 600-3/03 ABB Inc

35 Miniature Circuit Breakers S0 Series S0 MCBs Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding safety, reliability and switching capacities. The S0 heavy-duty circuit breaker fulfi lls these requirements by virtue of its technical features. It is equipped with a thermal and/or electromagnetic release to protect circuits, motors, switchgear and systems from the effects of overload and short-circuit currents. For the worldwide market, the S0 breakers carry UL, CSA, IEC, CE and many other agency approvals. Features High breaking capacity Energy-limiting Current-limiting Extremely fast breaking time Optimal selectivity Various versions for special applications Compact dimensions, DIN cap size Easy and quick to install Easy to connect; fi nger safe terminals Wide range of accessories UL 077 recognized 600VAC and 0V versions Low Voltage Products & s.37 ABB Inc AC 600-3/03

36 S0 277/600 VAC B UL 077 CSA C22.2 VDE 064 IEC C UL 077 CSA C22.2 VDE 064 IEC , , S-C6 S2-C6 S3-C0 AC B C Rated Catalog List Delivery Weight current number price class (oz.) pc 6 S-B6 $ 68 0 S-B S-B S-B S-B S-B2 68 B S-B S-B40 68 S-B S-B S2-B S2-B S2-B S2-B S2-B S2-B2 328 B S2-B S2-B S2-B S2-B S3-B S3-B S3-B S3-B S3-B S3-B2 478 B S3-B S3-B S3-B S3-B63 74 D UL 077 CSA C22.2 VDE 064 IEC 947- Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) 3 S-D3 $ 90 6 S-D S-D S-D S-D32 90 B S-D40 90 S-D S-D S2-D S2-D S2-D S2-D S2-D B S2-D S2-D S2-D S3-D S3-D S3-D S3-D S3-D32 44 B S3-D40 44 S3-D S3-D Rated Catalog List Delivery Weight current number price class (oz.) pc 6 S-C6 $ 68 0 S-C S-C S-C S-C S-C2 68 B S-C S-C40 68 S-C S-C S2-C S2-C S2-C S2-C S2-C S2-C2 328 B S2-C S2-C S2-C S2-C S3-C S3-C S3-C S3-C S3-C S3-C2 478 B S3-C S3-C S3-C S3-C63 74 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery 0, D AC AC Discount schedule CB0 Low Voltage Products & s AC 600-3/03 ABB Inc

37 S0 277/600 VAC S-D20 S2-D3 S3-K6 K 0, AC K UL 077 CSA C22.2 VDE 064 IEC-898 Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) S-K0. $ S-K S-K S-K S-K S-K S-K. 82. S-K S-K S-K S-K B S-K S-K S-K 82 0 S-K S-K S-K S-K S-K S-K S-K S2-K S2-K S2-K S2-K S2-K S2-K S2-K. 36. S2-K S2-K S2-K3 36 B S2-K S2-K S2-K S2-K 36 0 S2-K S2-K S2-K S2-K S2-K S2-K S2-K S3-K S3-K S3-K S3-K S3-K S3-K S3-K. 8. S3-K S3-K S3-K3 8 B S3-K S3-K S3-K S3-K 8 0 S3-K 8 20 S3-K S3-K S3-K S3-K S3-K S3-K4 828 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery Low Voltage Products & s Discount schedule CB0.39 ABB Inc AC 600-3/03

38 S0UC 600 VAC/V SUC-B40 S2UC-B6 B UL 077 CSA C22.2 VDE 0660 Rated Catalog List Delivery Weight current number price class (oz.) pc 6 SUC-B6 $ SUC-B SUC-B SUC-B SUC-B SUC-B2 226 C SUC-B SUC-B SUC-B SUC-B S2UC-B S2UC-B S2UC-B S2UC-B S2UC-B S2UC-B2 442 C S2UC-B S2UC-B S2UC-B 2 63 S2UC-B63 68 Rated Catalog List Delivery Weight current number price class (oz.) pc 6 S3UC-B6 $ S3UC-B S3UC-B S3UC-B S3UC-B S3UC-B2 646 C S3UC-B S3UC-B S3UC-B S3UC-B S4UC-B S4UC-B S4UC-B S4UC-B S4UC-B C S4UC-B S4UC-B S4UC-B S4UC-B S4UC-B63 64 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery S3UC-B 0, B AC Discount schedule CB0 Low Voltage Products & s AC 600-3/03 ABB Inc

39 S0 UC 600 VAC/V K VDE UL 077 CSA C SUC-K0. S2UC-K0. S3UC-K0. Rated Catalog List Delivery Weight current number price class (oz.) pc SUC-K0. $ SUC-K SUC-K SUC-K SUC-K SUC-K SUC-K. 2. SUC-K SUC-K SUC-K SUC-K4.2 2 C SUC-K SUC-K SUC-K 2 0 SUC-K 2 20 SUC-K SUC-K SUC-K SUC-K SUC-K SUC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K3 488 C S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K S2UC-K4 622 Rated Catalog List Delivery Weight current number price class (oz.) pc S3UC-K0. $ S3UC-K S3UC-K S3UC-K S3UC-K S3UC-K S3UC-K. 72. S3UC-K S3UC-K S3UC-K S3UC-K C S3UC-K S3UC-K S3UC-K 72 0 S3UC-K S3UC-K S3UC-K S3UC-K S3UC-K S3UC-K S3UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K3 996 C S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K S4UC-K4 276 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery 0, S4UC-K0. UC-K Low Voltage Products & s Discount schedule CB0.4 ABB Inc AC 600-3/03

40 Accessories S0 S0-H Auxiliary contacts Electrical Catalog List Delivery Wgt. oz. accessories number price class (pc.) Auxiliary contacts N.O./ N.C. S0-H 2 N.O. S0-H20 $ 84 B 2. 2 N.C. S0-H02 For fi eld mounting left side Bell alarm with auxiliary contacts N.O./ N.C. S0-S 2 N.O. S0-S20 92 B 2. 2 N.C. S0-S02 For fi eld mounting left side Handle mechanism S0-RD3 00 B 6. For use with -4 pole S0 MCBs and disconnect switch selector handles with mm shafts Electrical Catalog List Delivery Wgt. oz. accessories number suffi x price class (pc.) Undervoltage release 2 V UA2 24 V UA24 48 V UA48 0 V UA0 230 V UA230 0 V UA0 Factory mount only. Shunt trip 2 V AL2 24 V AL24 48 V AL48 0 V AL0 230 V AL230 0 V AL0 Factory mount only. $ 266 B B.7 Front mounting kit For pole S0-ME to 3 poles S0-ME2 70 A 2.9 to 7 poles S0-ME Power feed terminal S0-K2 $ 2 A 2 Suggested order quantity is. Busbars Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity 2 S0-BB23 $ S0-BB S0-BB43 32 A 363 S0-BB S0-BB Weight (ozs) Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to 2 week lead time E - Call for delivery.42 Discount schedule CB8 Low Voltage Products & s AC 600-3/03 ABB Inc

41 Technical data S0 Item S0-B, C, D S0-K Approvals: UL CSA C No.23 C No. 23 VDE 064/ /6.78 IEC No. of poles:,2,3, +N, +NA,2,3, +N, +NA Tripping characteristic: B.C.D. K Rated currents: 6 to 63A 0. to 4A Rated voltage: UL/CSA single pole 277VAC 277VAC UL/CSA multi pole 600VAC 600VAC IEC single pole 690VAC 690VAC Rated interrupting capacity: Single pole 6-2A 30KA/240VAC 0.-2A 30KA/240VAC KA/277VAC KA/277VAC 32-63A 8KA/240VAC 26-4A 8KA/240VAC KA/277VAC KA/277VAC Multi-pole 6-63A KA/480VAC 0.-4A KA/480VAC 6KA/600VAC 6KA/600VAC Frequency: /60 Hz /60Hz Mounting position: optional optional Standard mounting: 3mm DIN rail 3mm DIN rail Terminals: Conductors from 6-4AWG Conductors from 6-4AWG (-2sq mm) (-2sq mm) Service life at rated load: 20,000 operations 20,000 operations Calibration temperature: 40 C 40 C Approvals: UL CSA VDE No. of poles: Tripping characteristic: Rated currents: Rated voltage: UL single pole UL multi pole IEC multi pole Item S0UC-B, K 077 C ,2,3, 4 B, K B: 6 to 63A K: 0. to 4A 277VAC/2V 600VAC/600V 690VAC/7V Rated interrupting capacity: B single pole: 6 2A 8KA/240VAC KA/277VAC 30KA/2V 32 63A 30KA/240VAC KA/277VAC 30KA/2V B two-pole: 6 63A KA/480VAC 6KA/600VAC 30KA/0V B three-pole: 6 63A KA/480VAC 6KA/600VAC 30KA/600V K single pole: 0. 2A 30KA/240VAC KA/277VAC 30KA/2V 32 4A 8KA/240VAC KA/277VAC 30KA/2V K two-pole: 0. 4A KA/480VAC 6KA/600VAC 30KA/0V K three-pole: 0. 4A KA/480VAC 6KA/600VAC 30KA/600V Frequency: Mounting position: Standard mounting: Terminals: Service life at rated load: Calibration temperature: /60Hz optional 3mm DIN-rail Conductors from 6 to 4AWG (-2sq mm) 20,000 operations 40 C Low Voltage Products & s.43 ABB Inc AC 600-3/03

42 Approximate dimensions S0 Accessories Inches [Millimeters] S CL S0-RD3 Handle mechanism S0 Front mounting kit CL CUT-OUT "L" CL 0.24 D 6D L L L Low Voltage Products & s AC 600-3/03 ABB Inc

43 Residual current devices F370, F670 series 2 Pole 4 Pole Description RCDs provide ground fault equipment protection by monitoring the leakage of current to ground. The F370 and F670 series will trip when ground faults are detected in excess of the GF trip rating of the device. These devices provide GF pro tec tion only and are used in series with standard MCBs which provide overload and short circuit protection. The F370 and F670 series can be used as a main device providing GF protection for several MCB branch devices. The F370 and F670 series are UL03 recognized for use in 277/480VAC applications. The F372 is for use in single phase/two wire or two wire systems. The F374 is for use in three phase/four wire systems. The F370 and F670 series RCDs replace the F360 and F660 series with no change in form, fi t or function. The F370 and F670 have a profi le similar to the S2 MCBs and can be used with the MCB busbars. F370 F670 RCDs Low Voltage Products & s.4 ABB Inc AC 600-3/03

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description Miniature Circuit Breakers S260, S270, S280, S290 Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized under standard

More information

System pro M compact Miniature Circuit Br eakers Description Features

System pro M compact Miniature Circuit Br eakers Description Features System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2 S00-C, 480Y/77 VAC UL 077, CSA. Miniature C S0-C S0-C S03-C S04-C S0-CNA + NA 0.5 S0-C0.5 0.5 S03-C0.5 S0-C S03-C.6 S0-C.6.6 S03-C.6 S0-C S03-C 3 S0-C3 3 S03-C3 4 S0-C4 4 S03-C4 6 S0-C6 6 S03-C6 8 S0-C8

More information

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices UL 077 Series Supplementary protective devices The UL 077 Series miniature supplementary protector offers a compact solution for protection requirements. The devices are DIN rail mounted. The is available

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

US CATALOG. Miniature Circuit Breakers

US CATALOG. Miniature Circuit Breakers US CATALOG Miniature Circuit Breakers Miniature circuit breakers Table of contents S(U)200 series miniature circuit breakers UL 489 series Description and features 2 SU200M-C 3 SU200M-K 4 SU200M-Z 5 SU200MR-K

More information

US CATALOG. Miniature circuit breakers

US CATALOG. Miniature circuit breakers US CATALOG Miniature circuit breakers Table of contents 004 024 S(U)200 series miniature circuit breakers UL 489 series 025 048 S200 series miniature circuit breakers UL 1077 series 049 056 Application

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

smissline Description

smissline Description Modular power distribution bus system Description The power distribution bus system provides a versatile and flexible means of distributing power to a wide variety of electrical devices. Ideal for group

More information

System pro M compact Modular DIN rail components E220 - E270 Series

System pro M compact Modular DIN rail components E220 - E270 Series Modular DIN rail components E0 - E0 Series Description Safe connection by box terminals Captive screws with Pozidrive slotted head, Pozidrive system, Gr. Snap-on labels available Quick mounting with snap-on

More information

Miniature Circuit Breaker UL / CSA Range

Miniature Circuit Breaker UL / CSA Range PRODUCT CATALOG CANADA Miniature Circuit Breaker UL / CSA Range UL489 / CSA C22.2 No.5 devices UL1077 / CSA C22.2 No. 235 devices Electronic Protection Devices Technical data Miniature Circuit Breakers

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs Molded case circuit breakers S3 S8 S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch BA = Bell Alarm BA3 = Bell Alarm (S6/S7 only) S_ = Shunt trip with voltage code

More information

S4 N 250 B W - 2 xxx. Isomax MCCBs. Isomax Molded case circuit breakers S1 S8

S4 N 250 B W - 2 xxx. Isomax MCCBs. Isomax Molded case circuit breakers S1 S8 Molded case circuit breakers S1 S8 S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch BA = Bell Alarm BA3 = Bell Alarm (S6/S7 only) S_ = Shunt trip with voltage code

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Miniature circuit breaker Application guide

Miniature circuit breaker Application guide Miniature circuit breaker Application guide Miniature Miniature circuit circuit breakers breakers Application S200 guide Introduction The circuit breaker plays an important role in providing over-current

More information

Accessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5

Accessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5 Auxiliary contacts The auxiliary contacts will signal whether the breaker is in the ON or OFF position. For field mounting: right side SC-HRU SC-HRU Bell alarm The bell alarm includes a set of contacts

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact

More information

Proline Panelboard and breakers

Proline Panelboard and breakers Proline Panelboard and breakers ProLine & breakers ProLine The ProLine is the electrical industry's first limiting, touch safe, fully coordinated UL 67. Electrical: UL File #E319800 UL67 225A and 400A

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Low Voltage A GE Power Controls Company. General catalogue

Low Voltage A GE Power Controls Company. General catalogue Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5 Technical Data Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5 When connecting aluminum conductors, ensure that the contact surfaces of the conductors are

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Jtec 489 UL489 Branch Circuit Breaker

Jtec 489 UL489 Branch Circuit Breaker Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D

More information

Circuit Protection. Circiut Protection

Circuit Protection. Circiut Protection Circuit Protection Series L8 UL1077 Supplementary Protectors...2 Selection Guide - Trip Curve "B"...4 Selection Guide - Trip Curve "C"...5 Selection Guide - Trip Curve "D"...6 Accessories...7 Technical

More information

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7 EP60 Series...7-2 EP100 Series...7-4 EP100 ULH Series...7-6 EP100 UC Series (Branch Circuit Protection)...7-8 Series CA Auxiliary Switch and Bell Alarm...7-10 Series CB Auxiliary Switch and Bell Alarm...7-11

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz) AIR-COOLED SCREW LIQUID CHILLERS WIRING DIAGRAM New Release Form 201.19-W3 (1104) YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz) TABLE OF CONTENTS PAGE NOMENCLATURE...

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size Technical data UL Pilot Devices General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the

More information