AREA OF WORK ENERGY

Size: px
Start display at page:

Download "AREA OF WORK ENERGY"

Transcription

1 THIS DOCUMENT CONTAINS PROPRIETARY AREA OF WORK

2 THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25SM Controllers Chlorking & CO-2 controlled by chemical controller 3 x Chlorking Cells, 25 lb per day each CO-2 Supply Salt Controller & Sensor ph 7.4 On 7.4 ORP 750 Off 752 Flow Switch On Temperaure: Controller Sample Stream

3 THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25 Controller Chlorking & CO-2 controlled by chemical controller ph 7.4 On 7.4 ORP 750 Off 752 Flow Switch On Temperaure: 8 CO-2 Supply Chlorking Cell, 25 lb per day Salt Controller & Sensor Controller Sample Stream

4 THIS DOCUMENT CONTAINS PROPRIETARY

5 THIS DOCUMENT CONTAINS PROPRIETARY

6 0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" 00/3 70/3 PANEL "EPH" 00A, 480Y/277V, 3ɸ, 4W VFD 5/ VFD LAP POOL PUMP DIVE POOL PUMP TO BE REPLACED IN KIND DISCONNECT PER MECHANICAL EQUIPMENT CONNECTION SCHEDULE, TYPICAL OF (7) 70/3 00/3 60/2 J CHLOR 40 # " C., (3) #4, AND () #8 GND. XFMR "TEPL2" 30 KVA, Y/20V, 3ɸ, 4W -/4" C., (4) #2, AND () #8 GND. PANEL "EPL2" 00A, 208Y/20V, 3ɸ, 4W 60/2 J CHLOR 40 #2 30/2 J CHLOR 25SM 45/2 3 P 3 20/2 20/2 20/2 P P 2 P 4 ELECTRICAL LOAD CALCULATION FOR PANEL EPH Phase A B C A+B+C 20 HP Lap Pool Pump 9.35 kva 9.35 kva 9.35 kva kva +25% Largest Motor Load 2.34 kva 2.34 kva 2.34 kva 7.0 kva 5 HP Dive Pool Pump 2.0 kva 2.0 kva 2.0 kva 6.30 kva CHLOR 25SM CHLOR 40 CHLOR 40 P- P-2 P-3 P-4 SM- Total Load kva ( Existing and New) Total Load Amps ( Existing and New) 20/ J SM kva.56 kva.56 kva 3.2 kva 3.30 kva 3.30 kva 0.00 kva 6.60 kva 3.30 kva 0.00 kva 3.30 kva 6.60 kva 0.90 kva 0.90 kva 0.00 kva.80 kva 0.90 kva 0.00 kva 0.90 kva.80 kva 0.00 kva.95 kva.95 kva 3.90 kva 0.90 kva 0.90 kva 0.00 kva.80 kva 0.00 kva 0.00 kva.32 kva.32 kva kva kva22.82 kva68.30 kva A A 90.5 A 82.6 A Therefore 00A Panel, Breaker, and Feeder have capacity for the added load. Notes:. Existing loads calculated per 203 CEC SEE MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR CONDUIT AND CONDUCTOR SIZING Panel: Panel "EPH" Location: Lower Mechanical Area Volts: 277/480V Wye Mains: 00A Main Breaker Supply From: 0 Phases: 3 Bus Rating: 00A Mounting: Surface Wires: 4 AIC Rating: - Load Description Load (VA) Circuit Breaker Ckt Ckt Circuit Breaker Load (VA) A B C Amp Pole # # Amps Poles A B C Load Description (R) ChlorTec Spare Spare Spare HP Dive Pool Pump HP Lap Pool Pump Space Space Space Space Space Space Space Space Space Space Space Space Notes: Totals. kva Amps Phase A Phase B Phase C Total Panel: Panel "EPL2" Location: Lower Mechanical Area Volts: 20/208V Wye Mains: 00A Main Breaker Supply From: Panel "EPH" via Xfmr Phases: 3 Bus Rating: 00A Mounting: "TEPL2" Surface Wires: 4 AIC Rating: Match existing AIC Load Description Load (VA) Circuit Breaker Ckt Ckt Circuit Breaker Load (VA) Load Description A B C Amp Pole # # Amps Poles A B C CHLOR 40 #[] Pump P CHLOR 40 #2[] Pump P CHLOR 25SM [] Pump P Space Pump P-4 Space Space SM- Space Space Totals Notes:. Provide new GFCI circuit breaker with rating indicated matching existing breaker type and AIC ratings. kva Amps Phase A Phase B Phase C Total SHEET INDEX E0 ELECTRICAL SHEET INDEX, SYMBOL LIST, ABBREVIATIONS, PANEL SCHEDULES, LOAD CALCULATIONS, ONE-LINE DIAGRAM AND CONNECTION SCHEDULE E MECHANICAL AREA - UPPER LEVEL - ELECTRICAL E2 MECHANICAL AREA - LOWER LEVEL - ELECTRICAL E3 ELECTRICAL SPECIFICATIONS A AFF C CKT CB DIA FLA (F) SYMBOL LIST EXISTING ELECTRICAL BRANCH CIRCUIT PANEL - SURFACE MOUNTED NON-FUSED SAFETY SWITCH DISCONNECT. SIZE AS NOTED. NEW CONDUIT WITH WIRING AS NOTED ON PLANS. EXISTING CONDUIT WITH WIRING TO BE REMOVED. NUMBERED SHEET NOTE TAG. REFER TO MATCHING NUMBERED SHEET NOTE ON SAME SHEET. ELECTRICAL MOTOR - SIZED IN AS NOTED (EXAMPLE 5HP). AMPERE ABOVE FINISHED FLOOR CONDUIT CIRCUIT CIRCUIT BREAKER DIAMETER EXISTING FULL LOAD AMPERES FUTURE GALV GALVANIZED GFCI INTERRUPTER HZ JB KVA KW LT 5 GROUND-FAULT CIRCUIT HERTZ JUNCTION BOX KILOVOLT AMPERE KILOWATT LIGHT ABBREVIATIONS N.C. NIC N.S. NTS OC PNL PH (R) NORMALLY CLOSED NOT IN CONTRACT NURSE STATION NOT TO SCALE ON CENTER PANEL PHASE REMOVE RCPT RECEPTACLE SM SMS SHEET METAL SHEET METAL SCREW SWBD SWITCHBOARD TYP. V VA W WP TYPICAL VOLT VOLT AMPERE WATT WEATHERPROOF Whittington Electric, Inc. WEI Project#: Industrial Drive Auburn, CA Office (530) Fax (530) Engineering / Commercial / Industrial PARTIAL ONE-LINE POWER DIAGRAM SCALE: NONE MECHANICAL EQUIPMENT CONNECTION SCHEDULE EQUIPMENT DATA POWER SUPPLY CONDUIT & WIRE DISCONNECT SWITCH TYPE LOCATION SIZE DESIGNATION LOCATION HP OR KW FLA MCA MOCP PHASE VOLTS BREAKER POLES PANELBOARD OR MCC CKT # QUANTITIES AND SIZE SM- LOWER LEVEL -.0 A V 20 A EPL2 8 /2"C, (2) #2 & () #2 GND P UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 2,4 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 P2 UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 6,8 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 P3 UPPER LEVEL 3 HP 8.7 A 24.0 A 45.0 A 208 V 45 A 2 EPL2 0,2 /2"C, (2) #8 & () #0 GND F X - 45 A 3R 60A/2P 3 P4 UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 4,6 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 CHLOR 25 UPPER LEVEL A V 30 A 2 EPL2 9, /2"C, (2) #0 & () #0 GND NF X - - 3R 30A/2P 3 CHLOR 40- UPPER LEVEL A V 60 A 2 EPL2,3 3/4"C, (2) #6 & () #0 GND NF X - - 3R 60A/2P 3 CHLOR 40-2 UPPER LEVEL A V 60 A 2 EPL2 5,7 3/4"C, (2) #6 & () #0 GND NF X - - 3R 60A/2P 3 BLR- LOWER LEVEL A V 20 A - - /2"C, (2) #2 & () #2 GND BLR-2 LOWER LEVEL A V 20 A - - /2"C, (2) #2 & () #2 GND BLR-3 LOWER LEVEL A V 20 A - - /2"C, (2) #2 & () #2 GND BLR-4 LOWER LEVEL A V 20 A - - /2"C, (2) #2 & () #2 GND BLR-5 LOWER LEVEL A V 20 A - - /2"C, (2) #2 & () #2 GND Notes:. Mechanical to provide () SM- per sensor. See mechanical drawings. 2. Re-use existing circuits. Replacement in kind. No load chance. 3. Coordinate location with mechanical. See mechanical drawings. FUSED (F) OR NON-FUSED (NF) AT UNIT INTEGRAL FUSE SIZE NEMA ENCL. RATING NOTES Facility Project Sheet Title Scale: Drawn By: Checked By: REVIEW SET - NOT FOR CONSTRUCTION LANEY COLLEGE 900 FALLON STREET OAKLAND, CA LANEY COLLEGE POOL BOILER REPLACEMENT ELECTRICAL SHEET INDEX, SYMBOL LIST, ABBREVIATIONS, PANEL SCHEDULES, LOAD CALCULATION, ONE-LINE DIAGRAM, AND CONNECTION SCHEDULE AS NOTED Permit No.: Sheet E0 Issue Date: 07/5/206

7 0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" LOCATION OF NEW CHLORINATOR EQUIPMENT, COORDINATE WITH MECHANICAL MECHANICAL AREA - UPPER LEVEL - NEW ELECTRICAL SCALE: 3/4" = '-0" NUMBERED SHEET NOTES REMOVE EXISTING DISCONNECT, CONDUIT AND CONDUCTORS TO EXISTING CHLORINATION EQUIPMENT. Whittington Electric, Inc. WEI Project#: Engineering / Commercial / Industrial 940 Industrial Drive Auburn, CA Office (530) Fax (530) (R) DISCONNECT, EPH-,3,5 (R) CHLORINATION EQUIPMENT REVIEW SET - NOT FOR CONSTRUCTION Facility LANEY COLLEGE 900 FALLON STREET OAKLAND, CA Project LANEY COLLEGE POOL BOILER REPLACEMENT Sheet Title MECHANICAL AREA FLOOR PLAN - UPPER LEVEL - ELECTRICAL 2 PARTIAL MECHANICAL AREA - UPPER LEVEL - DEMO ELECTRICAL SCALE: 3/4" = '-0" Scale: Drawn By: Checked By: AS NOTED Permit No.: Sheet E Issue Date: 07/5/206

8 0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" 4 5HP DIVE POOL PUMP 5 20HP LAP POOL PUMP VFD, DIVE POOL PUMP (5) BOILERS TO BE REPLACED IN KIND 5 20 VFD, LAP POOL PUMP 2 PANEL "EPH" 9 PANEL "EPL2" 0 XFMR "TEPL2" 3 PANEL "EPL" (R) ABANDONED FUSED DISCONNECTS 6 ELECTRICAL GUTTER 7 (R) ABANDONED CONDUIT 8 MECHANICAL AREA - LOWER LEVEL - ELECTRICAL SCALE: 3/4" = '-0" NUMBERED SHEET NOTES EXISTING BOILERS TO BE REPLACED IN KIND. NO CHANGE IN PANEL/CIRCUIT LOADS. EXISTING 480/277V, 3 PHASE, 4 WIRE PANEL. SEE PANEL SCHEDULE, SHEET "E0". EXISTING 208/20V, 3 PHASE, 4 WIRE PANEL. EXISTING 5 HP DIVE POOL PUMP MOTOR TO BE REPLACE IN KIND. NO LOAD CHANGE. PROVIDE MEGGER TEST ON PHASE CONDUCTORS TO VERIFY CONDUCTOR INSULATION CONDITION. REPLACE CONDUCTORS IN KIND IF NECESSARY. EXISTING 20 HP LAP POOL PUMP MOTOR TO REMAIN. PROVIDE MEGGER TEST ON PHASE CONDUCTORS TO VERIFY CONDUCTOR INSULATION CONDITION. REPLACE CONDUCTORS IN KIND IF NECESSARY. Whittington Electric, Inc. WEI Project#: Industrial Drive Auburn, CA Office (530) Fax (530) Engineering / Commercial / Industrial 6 7 REMOVE EXISTING FUSED DISCONNECTS. CIRCUIT BREAKERS ARE WITHIN LINE OF SITE AND OF SUITABLE RATING FOR SHORT-CIRCUIT AND GROUND FAULT PROTECTION OF CONDUCTORS. RELOCATE CONDUCTOR SPLICES INTO ELECTRICAL GUTTER ABOVE. IDENTIFY AND PROVIDE LABELS FOR ALL CIRCUIT CONDUCTORS IN GUTTER. REMOVE ABANDONED CONDUITS AND PROVIDE KNOCKOUT SEALS. Facility REVIEW SET - NOT FOR CONSTRUCTION LANEY COLLEGE 900 FALLON STREET OAKLAND, CA REMOVE ABANDONED CONDUIT. EXISTING CAT CABLE TO REMAIN, PROVIDE NEW CABLE SUPPORTS ALONG CONCRETE WALL. Project 9 PROVIDE NEW BRANCH CIRCUIT PANEL. SEE ONE-LINE DIAGRAM AND PANEL SCHEDULE, SHEET "E0". LANEY COLLEGE POOL BOILER REPLACEMENT 0 PROVIDE NEW TRANSFORMER. SEE ONE-LINE DIAGRAM, SHEET "E0". EXTEND HOUSE KEEPING PAD AS NECESSARY. Sheet Title MECHANICAL AREA FLOOR PLAN - LOWER LEVEL - ELECTRICAL Scale: Drawn By: Checked By: Issue Date: AS NOTED 07/5/206 Permit No.: Sheet E2

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith University of California, San Diego Cal (IT) 2 Technical Assignment #2 Brian Smith Advisor: Dr. Moeck 31 October 2005 Brian Smith Lighting/Electrical Option University of California, San Diego Cal (IT)

More information

CM 352 Electrical Construction Estimating

CM 352 Electrical Construction Estimating CM 352 Electrical Construction Estimating Accubid Activity #4 Accubid Office Building 01 SWITCHGEAR, Distribution Designations and Switchgear Takeoff Building Distribution Designations 1. Start the program

More information

Recommended Procedures

Recommended Procedures Selective Coordination Study Recommended Procedures The following steps are recommended when conducting a selective coordination study.. One-Line Diagram Obtain the electrical system one-line diagram that

More information

A. This section includes unit capacitors for power factor correction.

A. This section includes unit capacitors for power factor correction. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less. PART 1: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information

Installing a Downstream Distribution Panelboard

Installing a Downstream Distribution Panelboard Job Sheet 5 Installing a Downstream Distribution Panelboard OBJECTIVE To install a downstream distribution panelboard (DDP) on the Mobile Workstation. To mechanically and electrically connect the DDP to

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings Your City logo here Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings PV TOOLKIT DOCUMENT #3 Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Spring Test 10 due 05/11/2013

Spring Test 10 due 05/11/2013 Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

GENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" TYP DH-108

GENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2 SPR-2 SPR-2 SPR-2 SPR-2 SPR-2 TYP DH-108 MATCH NE SEE SHEET E. N DH-6 DH-7 DH-9 DH-9 DH-8 DH-6 DH-8 MATCH NE SEE SHEET E. GENERAL NOTES KE PLAN NTS 407 North st Street, Suite 0 (5) 96-050 Fax (5) 96-06 N MATCH NE SEE SHEET E. DH- DH- DH- DH-7

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code 2. DEFINITIONS 2.1 ACCEPTABLE Acceptable to the Company. 2.2 ADVANCED METER A meter that is capable of remote reading, and is capable of storing electric consumption data at specified time intervals of

More information

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems not exceeding a total combined system ac inverter output rating of 10kW on the roof of a one- or two-family dwelling or

More information

Volume 2 Charts, Formulas, and Other Useful Information

Volume 2 Charts, Formulas, and Other Useful Information Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

CENTRIFUGAL CHILLER TECHNICAL DATA SHEET Job Name: Mt Healthy Junior Senior HS Date: 6/25/2009 Version: 06.12 Submitted By: Mary Wilking Unit Description: McQuay Model Number: WSC100MBJ72R/E4212-CE-3**/C3612-BLYY-2*****/R134-BAABM

More information

THE CARMONY BUILDING ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED ELECTRICAL SYMBOLS AND ABBREVIATIONS

THE CARMONY BUILDING ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED ELECTRICAL SYMBOLS AND ABBREVIATIONS LIGHTING ELECTRICAL SYMBOLS AND ABBREVIATIONS ABBREVIATIONS ELECTRICAL GENERAL NOTES EQUIPMENT POWER DEVICES NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION

More information

Commercial Meter Pedestals

Commercial Meter Pedestals Metering Pedestals - Features & s............................ 109 Metering Pedestals - Base Details............................. 110 Metering Pedestals - Pad Mounted.........................................

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Electrical Depth. Josh Kreutzberger Lighting/Electrical

Electrical Depth. Josh Kreutzberger Lighting/Electrical Electrical Depth Electrical Introduction The current power distribution system provides the building with power; however, an alternative design solution was analyzed. This analysis was done in order to

More information

Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Utility Main Service Transformers

Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Utility Main Service Transformers Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Main Service s INTRODUCTION by Robert E. Fuhr, P.E. The use of electronic equipment has dramatically increased

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to

More information

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections One-Line / Riser Diagrams Drawings are not reviewed prior to submission. Because of

More information

320A Single Phase URD Meter Loop Installations

320A Single Phase URD Meter Loop Installations 320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal

More information

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Owner s Manual For Automatic Transfer Switch 50 & 100 Amp Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Register your Generac product at: WWW.GENERAC.COM 888-436-3722

More information

East Central College

East Central College SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Wall switches. b. Receptacles c. Device plates and decorative box covers. 1.2 RELATED

More information

Electrical Design/Build Guide

Electrical Design/Build Guide 2017 Electrical Design/Build Guide Based on the 2017 National Electrical Code Copyright Durand & Associates 1986-2016 60 C Copper Ampacity 4 - Wire Fill - (Non-Current Carrying Neutral) 4 or 5 - Parallel

More information

Transmission & Distribution Glossary of Electrical Terms

Transmission & Distribution Glossary of Electrical Terms Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION

More information

Cole Service Building Boiler Replacement. Issued for Bidding and Construction August 30, 2012 Project Number G120270CD GENERAL ABBREVIATIONS

Cole Service Building Boiler Replacement. Issued for Bidding and Construction August 30, 2012 Project Number G120270CD GENERAL ABBREVIATIONS CITY OF OXFORD BUTLER COUNTY, OHIO OHIO VICINITY MAP MIAMI UNIVERSITY COLE SERVICE BUILDING BOILER REPLACEMENT CITY OF OXFORD, BULTER COUNTY, OHIO Issued for Bidding and Construction August 30, 2012 Project

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

Chapter 1 Electrical Theory...1

Chapter 1 Electrical Theory...1 Electrical Formulas with Sample Calculations Table of Contents Chapter 1 Electrical Theory...1 Unit 1 Electrician s Math and Basic Electrical Formulas...3 Part A Electrician s Math...3 1 1 Fractions...3

More information

CITY OF MOSES LAKE MUNICIPAL SERVICES DEPARTMENT EN GINEERING DIVISION

CITY OF MOSES LAKE MUNICIPAL SERVICES DEPARTMENT EN GINEERING DIVISION CITY OF MOSES LAKE MUNICIPAL SERVICES DEPARTMENT EN GINEERING DIVISION 321 South Balsam Street P.O. Box 1579 Mt)$es Lake, WA 98837 (509) 764-3183 WINONA LIFT STATION PROJECT- 2016 C.269 Bid Opening:, AUGUST

More information

SECTION DISTRIBUTION AND GROUNDING

SECTION DISTRIBUTION AND GROUNDING SECTION 16400 DISTRIBUTION AND GROUNDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Furnishing and installation of a complete electrical distribution and grounding system. B. Furnish and install motor control

More information

Standby Electric Generators for Alaskan Residences. Advice & Installation

Standby Electric Generators for Alaskan Residences. Advice & Installation Standby Electric Generators for Alaskan Residences Advice & Installation 452-1151 1-800-770-GVEA www.gvea.com Use of this publication is not a substitute for the use of sound judgement by the user. This

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park.

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park. City of Portsmouth Public Works Department June 27, 2014 Addendum #3 Bid #44-14 South Dock Replacement Prescott Park This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement

More information

FACT SHEET Standard: Electrical Safety

FACT SHEET Standard: Electrical Safety What is a Ground Fault Circuit Interrupter? FACT SHEET The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

American Electric Supply, Inc.

American Electric Supply, Inc. American Electric Supply, Inc. 6 S. Maple Street Date: 0/8/204 Corona, CA 92880 Telephone: 95-80-4665 Email: bmcdonald@amelect.com Fax: 95-552-626 Speedi Version: V 0.6 Valued Customer, Bill of Material

More information

MYRON ZUCKER CALMANUAL POWER FACTOR CORRECTION APPLICATION GUIDE INC.

MYRON ZUCKER CALMANUAL POWER FACTOR CORRECTION APPLICATION GUIDE INC. MYRON ZUCKER CALMANUAL POWER FACTOR CORRECTION APPLICATION GUIDE INC. CALMANUAL HOW TO APPLY CAPACITORS TO LOW VOLTAGE POWER SYSTEMS. SECTION INDEX SECTION I POWER FACTOR UNDERSTANDING POWER FACTOR...

More information

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation

More information

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT New Panelboard for Lot H, EV Charger Energization, Las Positas College Scope of Work and Technical Specifications Chabot-Las Positas Community College District

More information

LIFT STATION 11 ONE-LINE DIAGRAM

LIFT STATION 11 ONE-LINE DIAGRAM LAC JOB : 118-086 OSG-D-ELEC06.DWG LIFT STATION 11 ONE-LINE DIAGRAM DWG : SHEET : E15 33 47 NEW NEW GENERATOR PAD BOLLARD BOLLARD WETWELL ACCESS HATCH WETWELL OUTLINE HANDHOLE SEWER MANHOLE LIFT STATION

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

Electrical Depth. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC CURRENT SYSTEM

Electrical Depth. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC CURRENT SYSTEM CURRENT SYSTEM The current electrical system can best be described as star; one main switchboard that feeds to the main distribution panel, which then feeds the other panels. The normal power is provided

More information

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference 2010 / PM CM 21st Annual Conference The High-Velocity Edge: Achieving Operational Excellence ELECTRICAL / PM CM 2010 Conference Basic Electrical Rick Miller, PE, LEED AP RNM Engineering, Inc. Vanir Corp.

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

SECTION FIVE Electrical. 1A. MAIN LOBBY and LIBERTY AVENUE FACADE

SECTION FIVE Electrical. 1A. MAIN LOBBY and LIBERTY AVENUE FACADE SECTION FIVE Electrical 1A. MAIN LOBBY and LIBERTY AVENUE FACADE [with SECOND LEVEL LOBBY, GIFT SHOP, BOX OFFICE, GRAND STAIRCASE] Existing Design The main lobby is a large space with few distinct boundaries

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I recently installed a 45-KVA transformer, 480-volt primary

More information

DEWALT Electrical Licensing Exam Guide CONTENTS

DEWALT Electrical Licensing Exam Guide CONTENTS DEWALT Electrical Licensing Exam Guide v ONTENTS How to Prepare for the Exam................................................ 2 How to Study.............................................................

More information

1. Field verify measurements and circuiting arrangements as shown on as-built drawings.

1. Field verify measurements and circuiting arrangements as shown on as-built drawings. 26 00 00 Electrical 26 05 00 Common Work Results for Electrical 1. No more than three phase conductors, each of opposite phases for a three phase WYE system, shall be combined in a single raceway unless

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

What is included in a circuit diagram?

What is included in a circuit diagram? Circuit Diagrams What is included in a circuit diagram? Circuit diagrams use symbols to represent parts of a circuit, including a source of electrical energy and devices that are run by the electrical

More information

Spring Test 7 due 05/03/2013

Spring Test 7 due 05/03/2013 Spring Test 7 due 05/03/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A raceway contains two 3-phase, 3-wire circuits that supply 38 ampere continuous

More information

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX LAD05-9, CA 964 TITLE SHEET LAD05-9 SHEET INDEX 00 DEXTER AVE. SUITE 50 SEATTLE, WA 9809 PROJECT SUMMARY PROJECT DESCRIPTION COORDINATES LATITUDE: 33.678084 N LONGITUDE: -7.84858 W 0640 Sepulveda Blvd.

More information

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings Roof Top Solar Permit Document 1 Submittal Requirements Bulletin Small Town with a Big Backyard! Solar Photovoltaic Installations 10 kw or Less in One and TwoFamily Dwellings This information bulletin

More information

Solar PV Standard Electrical Plan

Solar PV Standard Electrical Plan *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Permit Number: SCOPE: Standard plan for installation of solar PV systems utilizing 2 wire

More information

Submittal Transmittal

Submittal Transmittal Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 9/12/2011 Reference

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand

More information

STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION CONTRACT PLANS FINANCIAL PROJECT ID (FEDERAL FUNDS) SEMINOLE COUNTY (77320)

STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION CONTRACT PLANS FINANCIAL PROJECT ID (FEDERAL FUNDS) SEMINOLE COUNTY (77320) CHIPLEY 7 CONTRACT PLANS PENSACOLA FORT WALTON BEACH PANAMA CITY TALLAHASSEE LAKE CITY JACKSONVILLE ST AUGUSTINE GAINESVILLE INDEX OF LIGHTING PLANS FINANCIAL PROJECT ID 000---0 OCALA DELAND DAYTONA BEACH

More information

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields

More information

TRANSMISSION SYSTEMS

TRANSMISSION SYSTEMS TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric

More information

Electrical Depth. Page 81

Electrical Depth. Page 81 Electrical Depth Introduction The existing electrical system for each space redesigned in my lighting depth had to be adjusted accordingly to the new design. The following electrical depth will illustrate

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

2010 National Electric Code

2010 National Electric Code PDHonline Course E361 (4 PDH) 2010 National Electric Code Instructor: Thomas Mason, P.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

M-1.0 FILE NAME: CAFE BIZOU CLIENT: CATHERINE MCKENNA PROJECT: PROJECT NO. REV DESCRIPTION DATE PLAN CHECK

M-1.0 FILE NAME: CAFE BIZOU CLIENT: CATHERINE MCKENNA PROJECT: PROJECT NO. REV DESCRIPTION DATE PLAN CHECK PLAN CHECK 11072016 12152016 12312015 : 20161122 20161107 20161215 20161020 PROJECT ME LEGEND, NOTES AND SCHEDULES M1.0 FILE ME: Elec. Panel Locker Rm. Electrical (N.I.C.) New Women's (E) Mop Only Sink

More information

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer Achieving Higher Short Circuit Current Ratings for Industrial Control Panels Standards & codes note 1 By Steve Hansen Sr. Field Engineer Introduction Articles 9.1 and. in the National Electrical Code require

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE 201 S. Anaheim Blvd. Page No. 3.2.1 A. GENERAL 1. The character of electric service available at any particular location should be ascertained by inquiry at the City's Electrical Engineering Division office.

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49 UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1 PART A ELECTRICIAN S MATH...1 Introduction...1 1.1 Whole Numbers...1 1.2 Decimal...1 1.3 Fractions...1 1.4 Percentages...2 1.5

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Solar PV Standard Electric Plan

Solar PV Standard Electric Plan *** Provide this document to the inspector along with ALL system installation instructions *** SCOPE: Standard plan for the installation of microinverter solar PV systems, not exceeding a total AC output

More information

EPRI s Utility Direct DC Fast Charger Development, Testing, Demonstration. Arindam Maitra IWC Meeting March 28, 2012

EPRI s Utility Direct DC Fast Charger Development, Testing, Demonstration. Arindam Maitra IWC Meeting March 28, 2012 EPRI s Utility Direct DC Fast Charger Development, Testing, Demonstration Arindam Maitra IWC Meeting March 28, 2012 Utility Direct Medium Voltage Fast Charger Conventional DC Fast Charger needs a new three-phase

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Applying Interrupting Rating: Circuit Breakers

Applying Interrupting Rating: Circuit Breakers The professional engineer must be qualified by primarily working in the design or maintenance of electrical installations. Documents on the selection shall be stamped and available to all necessary parties.

More information

Overcurrent Protection According to the 2011 NEC

Overcurrent Protection According to the 2011 NEC Overcurrent Protection According to the 2011 NEC Utah Electrical License This course will cover overcurrent protection according to the 2011 NEC. The key sections of Article 240 will be discussed. Overcurrent

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

Applying Interrupting Rating: Circuit Breakers

Applying Interrupting Rating: Circuit Breakers Series Rating: Protecting Circuit Breakers Generally, a circuit breaker should not be applied where the available shortcircuit current at its line side terminals exceeds the circuit breaker s interrupting

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com Power Quality Power Factor Wiring and Service Scope Power factor is a major consideration in efficient building or system operation. It is the measure of how effectively your equipment is converting electric

More information

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by Siemens STEP 2000 Course Busway It's easy to get in STEP! Download any course. Hint: Make sure you download all parts for each course and the test answer form. Complete each chapter and its review section

More information

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7 Construction Standards Page 1 of 7.1 General.1 New buildings are to be provided with an indoor unit substation designed to accept 15kV and 25kV primary voltages, however, the primary voltage connected

More information

For Conduit Inspections

For Conduit Inspections Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit

More information