STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION CONTRACT PLANS FINANCIAL PROJECT ID (FEDERAL FUNDS) SEMINOLE COUNTY (77320)
|
|
- Dwain Cain
- 5 years ago
- Views:
Transcription
1 CHIPLEY 7 CONTRACT PLANS PENSACOLA FORT WALTON BEACH PANAMA CITY TALLAHASSEE LAKE CITY JACKSONVILLE ST AUGUSTINE GAINESVILLE INDEX OF LIGHTING PLANS FINANCIAL PROJECT ID OCALA DELAND DAYTONA BEACH L- L- L-3 KEY TABULATION OF QUANTITIES GENERAL NOTES (FEDERAL FUNDS) SEMINOLE COUNTY (7730) PROJECT LOCATION NEW PORT RICHEY TAMPA ST PETERSBURG 7 ORLANDO LAKELAND BARTOW BEACH LINE EXPRESSWAY FLORIDA'S TURNPIKE MELBOURNE - COCOA L- L- L-6 POLE DATA AND LEGEND POLE DATA PROJECT LAYOUT STATE ROAD (WEKIVA PARKWAY SECTION 7A) 7 SARASOTA - BRADENTON 7 FT PIERCE L-7 Thru L- LIGHTING PLAN WEST PALM L- L- L- UNDER DECK LIGHTING DETAILS SERVICE POINT DETAIL LOAD CENTER A SERVICE POINT DETAIL LOAD CENTER B LIGHTING PLANS NAPLES FT MYERS 7 7 BEACH FT LAUDERDALE L-7 SERVICE POINT DETAIL LOAD CENTER C MIAMI L- SERVICE POINT DETAIL LOAD CENTER D L- SERVICE POINT DETAIL LOAD CENTER E L-0 SERVICE POINT DETAIL LOAD CENTER F L- SERVICE POINT DETAIL LOAD CENTER G KEY WEST SUNE S. LICEN SE No. 6 HERTZ THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY: STATE OF PROFESSIONALENGINEER FLORI D A PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED. THE SIGNATURE MUST BE VERIFIED IN THE ELECTRONIC DOCUMENTS. LIGHTING PLANS ENGINEER OF RECORD: SUNE S. HERTZ, P.E. P.E. 6 TRAFFIC ENGINEERING DATA SOLUTIONS, INC. 0 SPRING VISTA DRIVE DEBARY, FL 37 CONTRACT : CB VENDOR : F CERTIFICATE OF AUTHORIZATION 73 FDOT PROJECT MANAGER: KEVIN MOSS, P.E. CONSTRUCTION CONTRACT FISCAL YEAR T66 L- //07 :3:3 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\keyslt0
2 TABULATION OF QUANTITIES PAY ITEM UNIT NUMBERS L-7 L- L- L- L- L- L- TOTAL THIS GRAND TOTAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL CONDUIT, FURNISH & INSTALL, OPEN TRENCH LF CONDUIT, FURNISH & INSTALL, DIRECTIONAL BORE LF CONDUIT, FURNISH & INSTALL, ABOVEGROUND LF CONDUIT, FURNISH & INSTALL, BRIDGE MOUNTED LF PULL & SPLICE BOX, F&I, " x " EA 63-- ELECTRICAL POWER SERVICE, F&I, UNDERGROUND, METER PURCHASED BY CONTRACTOR AS 6-- PRESTRESSED CONRETE POLE, F&I, TYPE P-II PEDESTAL EA 6-- PRESTRESSED CONRETE POLE, F&I, TYPE P-II SERVICE POLE EA 7-- LIGHTING CONDUCTORS, F&I, INSULATED, OR < LF LIGHTING CONDUCTORS, F&I, INSULATED, 6 LF LIGHTING CONDUCTORS, F&I, INSULATED, TO 0 LF LIGHT POLE COMPLETE FURNISH & INSTALL STANDARD POLE STANDARD FOUNDATION, 30' MOUNTING HEIGHT EA LIGHT POLE COMPLETE FURNISH & INSTALL STANDARD POLE STANDARD FOUNDATION, 0' MOUNTING HEIGHT EA LIGHT POLE COMPLETE FURNISH & INSTALL STANDARD POLE SPECIAL FOUNDATION, 30' MOUNTING HEIGHT EA LUMINAIRE, F&I, ROADWAY, COBRA HEAD EA 7-7- LOAD CENTER, F&I, SECONDARY VOLTAGE EA LUMINAIRE, UNDER DECK PENDANT, F&I, Project EA LUMINAIRE, F&I, UNDER DECK, WALL MOUNT EA POLE CABLE DISTRIBUTION SYSTEM, CONVENTIONAL EA POLE CABLE DISTRIBUTION SYSTEM, WALL MOUNT EA THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE TABULATION OF QUANTITIES L- //07 :3:3 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\TABQLT0
3 GENERAL NOTES. PRIOR TO ANY EQUIPMENT ORDER, THE CONTRACTOR SHALL SUBMIT FOR APPROVAL EQUIPMENT SPECIFICATION OR DESIGN DATA FOR ALL MATERIAL PROPOSED FOR THE PROJECT. THESE MUST SPECIFICALLY INCLUDE: A) LUMINAIRE PHOTOMETRICS D) POLE STRENGTH CALCULATIONS B) LOAD CENTER ELECTRICAL EQUIPMENT E) POLE FRANGIBILITY TEST C) POLE SHOP DRAWINGS F) BOLT SPECIFICATIONS AND BOLT CIRCLE DIAMETER SUBMITTAL DATA SHALL INCLUDE COMPUTER PRINTOUT SHOWING HORIZONTAL FOOT CANDLE LEVELS TO BE OBTAINED USING THE SUBMITTED LUMINAIRES ON THIS PROJECT. AT FINAL INSPECTION, THE CONTRACTOR SHALL VERIFY THE HORIZONTAL FOOT-CANDLE LEVELS ON THE ROADWAY WITH AN APPROVED CURRENTLY CALIBRATED LIGHT METER. PAYMENT TO BE INCIDENTAL TO THE LIGHTING AND LUMINAIRE PAY ITEM NUMBERS. A REPORT DETAILING ACTUAL FIELD LIGHT LEVEL READINGS SHALL BE SUBMITTED FOR APPROVAL. SEVEN COPIES OF SHOP DRAWINGS AND DESIGN DATA FOR HIGHWAY LIGHTING EQUIPMENT AND LOAD CENTER ELECTRICAL EQUIPMENT SHALL BE SUBMITTED TO THE ENGINEER IN CHARGE OF THE PROJECT.. LIGHTING CONTRACTOR SHALL COORDINATE WITH STRUCTURAL CONTRACTOR TO ENSURE PROPER MOUNTING BOLT CIRCLES ARE CONSTRUCTED FOR THE PROPOSED POLE BASES AND TO COORDINATE LOCATIONS OF EMBEDDED CONDUIT AND PULL BOXES WITHIN THE WALLS AND BRIDGES.. PULL BOXES AND LOAD CENTERS SHALL NOT BE PLACED IN DITCHES OR LOW LYING AREAS IN ORDER TO AVOID INTRUSION.. ALL POLE SET BACKS SHOWN ON THE POLE DATA S ARE AS FOLLOWS: - ALL UNDER DECK AND WALL MOUNTED FIXTURES AND LOAD CENTERS ARE FROM THE OF CONSTRUCTION FOR SR - ALL POLES ARE FROM THE NEAREST FRONTAGE ROAD/SIDE STREET BASELINE.. ALUMINUM POLES, LUMINAIRES AND BASES SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH AASHTO "STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS" AND SHALL HAVE BEEN TESTED BY FHWA-APPROVED METHODS. CERTIFICATION FOR TESTS SHALL BE SUBMITTED WITH THE SHOP DRAWINGS.. INSTALL SURGE PROTECTORS, PROPERLY GROUNDED, IN POWER (SECONDARY) ENTRANCES.. IN ACCORDANCE WITH N.E.C., IDENTIFY ALL CIRCUITS AND EQUIPMENT WITH "LAMACOID TAGS". INSTALL SIMILAR TAGS OF STAINLESS STEEL IDENTIFYING THE CIRCUIT FOR EACH LUMINAIRE AT ACCESS HANDHOLE FOR EACH POLE.. THE CONTRACTOR SHALL NOTIFY FLORIDA POWER & LIGHT AT LEAST BUSINESS DAYS PRIOR TO ANY INSTALLATION THAT IS WITHIN TEN () FEET OF ENERGIZED ELECTRICAL CONDUCTORS. FLORIDA POWER & LIGHT, AT ITS OPTION, SHALL ASSIST THE CONTRACTOR, PROVIDE PROTECTION FOR ENERGIZED CONDUCTORS AT INSTALLATION SITE, OR TAKE OTHER SAFETY PRECAUTIONS AS NECESSARY. EXTREME CAUTION SHALL BE EXERCISED AT ALL TIMES IN PERFORMANCE OF WORK AROUND PRIMARY HIGH VOLTAGE COMPONENTS. 6. PULLING INSTRUCTIONS: CONNECT PULLING DEVICES TO COPPER WIRE AND NOT TO JACKET AND MEET MANUFACTURER'S REQUIREMENTS. USE PULLING COMPOUND PER MANUFACTURER'S REQUIREMENTS. ALL BENDS SHALL NOT BE LESS THAN RECOMMENDED BY N.E.C. OR N.E.S.C. FOR CABLE USED. PULL CABLE SHALL BE POLYESTER. STEEL CABLE OR FISH TAPES SHALL NOT BE UTILIZED. 7. CONTRACTOR SHALL PREPARE ACCURATELY DIMENSIONED "AS BUILT" PLANS OF FINAL POLE, CONTROLLER, CABLE AND CONDUIT PULL BOX LOCATIONS. PLANS SHALL BE REVIEWED AND APPROVED BY THE ENGINEER AND SUBMITTED TO THE RESIDENT ENGINEER. COST OF SUCH PREPARATION SHALL BE INCIDENTAL TO PAY ITEMS PROVIDED.. INSPECT ALIGNMENT OF EACH INDIVIDUAL POLE AND FIXTURE AS FOLLOWS: POLE ALIGNMENT: WITHIN ONE HALF DEGREE ON VERTICAL +/-, CONFIRM VERTICAL ALIGNMENT, VIEWING FROM ADJACENT SERIES OF POLES, IN BOTH DIRECTIONS. FIXTURE ALIGNMENT: WITHIN ONE DEGREE OF HORIZONTAL +/-, USING CALIBRATED LEVEL ALONG BOTH AXES OF CUT-OFF FIXTURE FACE, WITH LENS ONLY.. SCREW TYPE ANCHOR FOUNDATION IS NOT TO BE USED ON THIS PROJECT. THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE GENERAL NOTES L-3 //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\GNNTLT0
4 POLE DATA CONVENTIONAL LIGHTING DESIGN CRITERIA POLE CIRCUIT STATION / BASELINE POLE OFFSET ARM LENGTH WATTAGE MOUNTING HEIGHT PAY ITEM NUMBER ** A / CONST. WB FRONTAGE RD.' LT ' 30' 7-- Average Initial Intensity Uniformity Ratio Avg./Min. Max. / Min.. Foot Candles : or Less : or Less Note: Sidewalks and under deck roadway areas shall use conventional lighting criteria. A / CONST. WB FRONTAGE RD.0' LT ' 30' A / CONST. WB FRONTAGE RD 3.0' LT ' 30' 7-- Wind Speed Veiling Luminance MPH 0.3 or Less A / CONST. WB FRONTAGE RD.3' LT ' 30' 7-- A / CONST. EB FRONTAGE RD.3' RT ' 30' 7-- LEGEND 6** A / CONST. EB FRONTAGE RD.' RT ' 30' 7-- 7** A / CONST. EB FRONTAGE RD.' RT ' 30' 7-- SYMBOLS ** A- 06+./ CONST. EB FRONTAGE RD 7.' RT ' 30' 7-- ** A / CONST. EB FRONTAGE RD.7' RT ' 30' 7-- ** A / CONST. EB FRONTAGE RD.3' RT ' 30' 7-- ** B- 30+./ CONST. WB FRONTAGE RD 3.6' LT ' 30' 7-- B / CONST. WB FRONTAGE RD.' LT ' 30' 7-- ** B / CONST. WB FRONTAGE RD 6.6' LT ' 30' 7-- ** B / CONST. WB FRONTAGE RD 7.' LT ' 30' 7-- B / CONST. EB FRONTAGE RD.' RT ' 30' 7-- ** B / CONST. EB FRONTAGE RD.' RT ' 30' 7-- 7** B / CONST. EB FRONTAGE RD 33.' RT ' 30' 7-- ** B / CONST. EB FRONTAGE RD.' RT ' 30' 7-- C / CONST. WB FRONTAGE RD 3.' LT ' 30' C / CONST. WB FRONTAGE RD 33.3' LT ' 30' 7-- C / CONST. WB FRONTAGE RD 33.' LT ' 30' 7-- C / CONST. WB FRONTAGE RD 3.' LT ' 30' 7-- 3** C- 0+.3/ CONST. EB FRONTAGE RD 30.' RT ' 30' 7-- ** C / CONST. EB FRONTAGE RD.' RT ' 30' 7-- ** C / CONST. EB FRONTAGE RD 6.3' RT ' 30' 7-- 6** C- 0+./ CONST. EB FRONTAGE RD.' RT ' 30' D- 3+.6/ CONST. WB FRONTAGE RD 37.6' LT ' 30' 7-- D / CONST. WB FRONTAGE RD 3.' LT ' 30' 7-- D / CONST. WB FRONTAGE RD 3.' LT ' 30' D- 3+3./ CONST. WB FRONTAGE RD 3.6' LT ' 30' D / CONST. EB FRONTAGE RD 0.' RT ' 30' 7-- 3** D / CONST. EB FRONTAGE RD.' RT ' 30' ** D- +7./ CONST. EB FRONTAGE RD 6.3' RT ' 30' 7-- 3** D- +7./ CONST. EB FRONTAGE RD 36.3' RT ' 30' 7-- 3** G- 3+./ CONST. ORANGE BLVD.' LT ' 0' ** G- 3+.3/ CONST. ORANGE BLVD 3.7' LT ' 0' ** G- 3+6./ CONST. ORANGE BLVD 6.3' LT ' 0' 7-- 3** G- +6./ CONST. ORANGE BLVD.7' RT ' 0' 7-- 3** G- +6.6/ CONST. ORANGE BLVD.6' LT ' 0' 7-- 0** G- +0./ CONST. ORANGE BLVD 6.' RT ' 0' 7-- MA- G / CONST. WB FRONTAGE RD 7.' LT ' 0' 7--3 MA- G- +6./ STATE ROAD 6.' LT ' 0' 7--3 MA-3 G- +3./ STATE ROAD 6.6' RT ' 0' 7--3 MA- G- +.6/ CONST. EB FRONTAGE RD.' RT ' 0' 7--3 ** Pole installation requires an extended foundation due to : or greater slope. Wall mounted watt LED luminaire (Philips Road Focus model RFLW6LEDK-T-UNIV or equal). Designed for TYPE IV short distribution. Bug rating = B3-U0-G. Integral regulator type ballast wired for 0 volt operation. Pole mounting height 30 ft with ft. arm. Use Philips Test No. S-R. Shoulder mounted watt LED luminaire (Philips Road Focus model RFLW6LEDK-T-UNIV or equal). Designed for TYPE IV short distribution. Bug rating = B3-U0-G. Integral regulator type ballast wired for 0 volt operation. Pole mounting height 30 ft with ft. arm. Use Philips Test No. S-R. Mast arm mounted watt LED luminaire (Philips Road Focus model RFLW6LEDK-T-UNIV or equal). Designed for TYPE IV short distribution. Bug rating = B3-U0-G. Integral regulator type ballast wired for 0 volt operation. Pole mounting height 0 ft with ft. arm. Use Philips Test No. S-R. Shoulder mounted watt LED luminaire (Philips Road Focus model RFLW6LEDK-T-R3M or equal). Designed for TYPE III medium distribution. Bug rating = B3-U0-G3. Integral regulator type ballast wired for 0 volt operation. Pole mounting height 0 ft with ft. arm. Use Philips Test No. S-R. Pendant hung underdeck luminaire, 7 watt LED luminaire (McGraw model No. VPL-E0-LED-EI-WQ, or equal). Designed for TYPE VS short distribution. Bug rating = B3-U0-G. Integral regulator ballast wired for 0 volt operation. 0% of luminaire to be below bridge beam. Use EATON/McGraw-Edison Test P30. Pier cap mounted luminaire, 7 watt LED luminaire (Holophane model No. WG_LED_0C_00_0K_T3M or equal), equipped with glass refractor. Designed for TYPE IV short distribution. Bug rating = B-U3-G3. Integral regulator ballast wired for 0 volt operation. Use Holophane Test No. LTL7P3. Schedule 0 PVC underground conduit with conductors inside (conductor size as shown on plan sheets). Run one () copper bond conductor (green insulation) inside conduit with other conductors. Schedule 0 PVC underground conduit directional bored under pavement with one () spare conduit and conductors inside (conductor size as shown on plan sheets). Extend conduit beyond edge of pavement to pull boxes. Run one () copper bond conductor (green insulation) inside conduit with other conductors. Rigid galvanized steel conduit bridge mounted with conductors inside (conduit and conductor size as shown on plan sheets). Run one () copper bond conductor (green insulation) inside conduit with other conductors. Schedule 0 PVC embedded conduit. To be placed inside the bridge barrier wall. See structural plans for details. Pull box. Distribution point. Utility pole with service transformer by power company. (Final location TBD) THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE POLE DATA AND LEGEND L- //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\pldtlt0
5 POLE DATA POLE DATA POLE CIRCUIT STATION / BASELINE POLE OFFSET ARM LENGTH WATTAGE MOUNTING HEIGHT PAY ITEM NUMBER POLE CIRCUIT STATION / BASELINE POLE OFFSET ARM LENGTH WATTAGE MOUNTING HEIGHT PAY ITEM NUMBER UD- A- 6+.0/ CONST. SR.0' LT 0' 7 ' 7-- UD- A- 6+./ CONST. SR.' LT 0' 7 ' 7-- UD-3 A / CONST. SR.' LT 0' 7 ' 7-- UD- A / CONST. SR.' LT 0' 7 ' 7-- UD- A- 6+.3/ CONST. SR 3.6' RT 0' 7 ' 7-- UD-6 A- 6+.3/ CONST. SR 3.' RT 0' 7 ' 7-- UD-7 A / CONST. SR 3.' RT 0' 7 ' 7-- UD- A / CONST. SR 3.6' RT 0' 7 ' 7-- UD- B- 7+6./ CONST. SR 3.7' LT 0' 7 ' 7-- UD-3 D- 6+3./ CONST. SR 0.3' RT 0' 7 0' 7-- UD-3 D / CONST. SR 3.6' RT 0' 7 0' 7-- UD-33 D / CONST. SR 0.' RT 0' 7 0' 7-- UD-3 D- +0.3/ CONST. SR 3.7' RT 0' 7 0' 7-- UD-3 D- +0.3/ CONST. SR.' RT 0' 7 0' 7-- UD-36 E- +3.0/ CONST. SR 3.0' RT 0' 7 3' 7-- UD-37 E- +3./ CONST. SR 6.0' RT 0' 7 3' 7-- UD-3 E- +.7/ CONST. SR.' LT 0' 7 3' 7-- UD-3 E- +3./ CONST. SR.' RT 0' 7 ' 7-- UD- B- 7+7./ CONST. SR 3.' LT 0' 7 ' 7-- UD- B- 0+0./ CONST. SR.3' LT 0' 7 ' 7-- UD- B- 0+./ CONST. SR 36.7' LT 0' 7 ' 7-- UD- B- +./ CONST. SR 37.0' LT 0' 7 ' 7-- UD- B- 7+6./ CONST. SR 37.' RT 0' 7 ' 7-- UD- B- 7+./ CONST. SR 36.' RT 0' 7 ' 7-- UD- B- 0+./ CONST. SR 37.' RT 0' 7 ' 7-- UD-7 B- +./ CONST. SR 36.' RT 0' 7 ' 7-- UD- C- +.6/ CONST. SR.' LT 0' 7 ' 7-- UD- C- +33./ CONST. SR 7.' LT 0' 7 ' 7-- UD-0 C- 3+6./ CONST. SR 7.' LT 0' 7 ' 7-- UD- C- +3./ CONST. SR.3' LT 0' 7 ' 7-- UD- C- +7.6/ CONST. SR.3' RT 0' 7 ' 7-- UD-3 C- +33./ CONST. SR.' RT 0' 7 ' 7-- UD- C / CONST. SR.7' RT 0' 7 ' 7-- UD- C / CONST. SR.' RT 0' 7 ' 7-- UD-6 C- +./ CONST. SR 3.0' RT 0' 7 ' 7-- UD-7 D / CONST. SR 7.' LT 0' 7 0' 7-- UD- D- 7+./ CONST. SR 3.6' LT 0' 7 0' 7-- UD- D- +.3/ CONST. SR 3.' LT 0' 7 0' 7-- UD-30 D- +03./ CONST. SR 33.' LT 0' 7 0' 7-- UD-0 E- 3+.7/ CONST. SR.' LT 0' 7 3' 7-- UD- E- 3+.6/ CONST. SR.0' RT 0' 7 ' 7-- UD- E / CONST. SR.' LT 0' 7 ' 7-- UD-3 E- +./ CONST. SR.0' LT 0' 7 ' 7-- UD- F- +.6/ CONST. SR.7' RT 0' 7 ' 7-- UD- F- +./ CONST. SR 6.0' RT 0' 7 ' 7-- UD-6 F- +./ CONST. SR.6' LT 0' 7 ' 7-- UD-7 F- +07./ CONST. SR 3.' LT 0' 7 ' 7-- UD- F- +60./ CONST. SR.' RT 0' 7 ' 7-- UD- F- +67./ CONST. SR.' RT 0' 7 ' 7-- UD-0 F- +76./ CONST. SR.3' LT 0' 7 ' 7-- UD- F- +./ CONST. SR.' LT 0' 7 ' 7-- UD- F- 7+.6/ CONST. SR 0.' LT 0' 7 ' 7-- UD-3 F- 7+7./ CONST. SR 0.0' LT 0' 7 ' 7-- UD- F- +6.0/ CONST. SR.0' RT 0' 7 ' 7-- UD- F- +6.3/ CONST. SR 3.' RT 0' 7 ' 7-- UD-6 F- +00./ CONST. SR.' LT 0' 7 ' 7-- UD-7 F / CONST. SR.3' LT 0' 7 ' 7-- UD- F- +0.0/ CONST. SR.' RT 0' 7 ' 7-- UD- F- +0.6/ CONST. SR 7.' RT 0' 7 ' 7-- THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE POLE DATA L- //07 :3: PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\pldtlt0
6 YANKEE LAKE RO AD STA L-7 L- N SR END LIGHTING L- STA L- L- SR 6 MA- STA ' LT. MA- POLE No. 36 STA STA ' LT.' LT POLE No. 37 STA POLE No ' RT STA. 3+..' LT V V V V POLE No. 0 STA ' LT MA- STA. +.6.' RT MA-3 POLE No. 3 STA. +3. STA ' RT.7' RT STA ' LT RO AD D RIVE LAKE M ARKH AM G LAD E VIEW KRSWKA KRSWKB L- S. ORANGE AVENUE END LIGHTING STA END PROJECT STA L- SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD SR COUNTY PROJECT LAYOUT FINANCIAL PROJECT ID SEMINOLE O RANG E BO ULEVARD LO NG W O O D M ARKH AM STA RO AD POLE No. 3 BEGIN LIGHTING THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. BEGIN PROJECT L //07 :3: PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\gnntlt0
7 RAW 70 3 POLE No. STA ' LT POLE No. STA ' LT POLE No. 3 STA ' LT POLE No. STA ' LT R/W LINE N SR 6 WB SR EB EXIST. R/W LINE BEGIN LIGHTING STA SR 6 EB LONGW OOD MARKH AM ROAD ELEC CONST. EB FRONTAGE ROAD CONST. WB FRONTAGE ROAD SR WB CONST. SR (WEKIVA PARKWAY) CONST. SR (WEKIVA PARKWAY) POLE No. STA ' RT LOAD CENTER A STA. 6+7.,.' RT 0/0 VAC (SEE ITS PLANS FOR SERVICE INFO) STA ' LT UD- UD- STA ' RT POLE No. 6.' RT POLE No. 7 STA ' RT 0 STA #6 CKT A- -#6 CKT GROUND -# CKT A- -# CKT GROUND (TYP. FOR UNDERDECK FIXTURES) UD-6 STA ' RT 0 UD- STA. 6+..' LT -#6 CKT A- -#6 CKT GROUND 06 3 UD-7 UD-3 STA ' LT STA ' RT POLE No. STA ' RT POLE No. STA ' RT UD- STA ' LT UD- STA ' RT POLE No. STA ' RT SR 6 EB EXIST. R/W LINE Feet 0 THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE LIGHTING PLAN L-7 //07 :3: PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\planlt0
8 ELEC POLE No. STA ' LT R/W LINE POLE No. STA ' LT YANKEE LAKE ROAD POLE No. STA ' LT POLE No. STA ' LT N CONST. SR (WEKIVA PARKWAY) SR 6 EB CONST. EB FRONTAGE ROAD POLE No. STA ' RT UD- -#6 CKT B- 3.7' LT SOURCE 303 STA UD- STA ' RT PROPOSED POWER -# GROUND 03 -# SERVICE WIRE SERVICE DISCONNECT STA. 7+.3,.' RT 0/0 VAC 30 -#6 CKT B- UD- STA ' LT UD- STA ' RT POLE No. 7 STA ' RT LOAD CENTER B POLE No. STA ' RT UD- STA ' LT UD- STA ' LT UD- STA ' RT -#6 CKT B- POLE No. STA ' RT UD- STA ' LT -# CKT B- -# GROUND (TYP. FOR UNDERDECK FIXTURES) UD-7 STA ' RT SR 6 EB EXIST. R/W LINE SR WB SR EB SR 6 WB CONST. WB FRONTAGE ROAD CONST. EB FRONTAGE ROAD Feet 0 THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE LIGHTING PLAN L- //07 :3:3 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\planlt0
9 R/W LINE POLE No. STA ' LT POLE No. 0 STA ' LT POLE No. STA ' LT POLE No. STA ' LT R/W LINE N TH TH THD THC THB THA TH 00 CONST. WB FRONTAGE ROAD CONST. SR (WEKIVA PARKWAY) TH CONST. EB FRONTAGE ROAD THA UD- STA. +.6.' LT 0 -#6 CKT C- -#6 CKT GROUND 0/0 VAC 0 LOAD CENTER C STA. +6.7,.' RT (SEE ITS PLANS FOR SERVICE INFO) UD- STA ' RT 0.' RT TH POLE No. TH POLE No. 3 STA ' RT STA TH6 TH7 TH0 -#6 CKT C- -#6 CKT GROUND UD-3 STA ' RT THA TH UD- STA ' LT LAKE MARKH AM ROAD UD-0 STA ' LT UD- STA ' RT.' RT TH TH POLE No. STA ' RT TH UD- STA ' LT TH TH TH7 TH3 6 3 UD- STA #6 CKT C- -#6 CKT GROUND -# CKT C- -# GROUND (TYP. FOR UNDERDECK FIXTURES) UD-6 STA ' RT POLE No. 6 STA. 0+..' RT 30 0 SR EB TH TH 3 3 SR WB CONST. SR (WEKIVA PARKWAY) CONST. EB FRONTAGE ROAD 0 0 THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. TH3 Feet SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE LIGHTING PLAN L- //07 :3: PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\planlt03
10 S- POLE No. STA R/W LINE 3.' LT POLE No. STA ' LT N POLE No. 30 POLE No. 7 STA ' LT STA ' LT 3 30 IVA PARKWAY) CONST. WB FRONTAGE ROAD SR WB CONST. EB FRONTAGE ROAD SR 6 WB 6 UD-7 STA ' LT UD-3 STA ' RT 3 PROPOSED POWER SOURCE -# GROUND POLE No. 3 STA ' RT POLE No. 3 STA ' RT -# SERVICE WIRE DISCONNECT 7 SERVICE LOAD CENTER D STA. 7+.6, 7.' RT 0/0 VAC #6 CKT D- -#6 CKT D- GLADE VIEW DRIVE UD- STA ' LT UD-3 STA ' RT GLADE VIEW DR UD- STA ' LT CONST. SR (WEKIVA PARKWAY) PE No. 6 0 Spring Vista Drive DeBary, FL 37 SUNE S. HERTZ, P.E. 0 Phone: Fax: CERTIFICATION OF AUTHORIZATION # UD-3 STA ' RT UD-33 STA ' RT ROAD SR POLE No. 33 STA ' RT COUNTY SEMINOLE 3 UD-30 STA ' LT -# CKT C- -# GROUND (TYP. FOR UNDERDECK FIXTURES) UD-3 STA ' RT POLE No. 3 STA ' RT FINANCIAL PROJECT ID 3 SR 6 WB CONST. WB FRONTAGE ROAD CONST. EB FRONTAGE ROAD LIGHTING PLAN 0 Feet 0 L- THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. //07 :3:7 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\planlt0
11 SR WB SR EB TH SR 6 EB UD-36 STA ' RT CKT. E- PROPOSED POWER SOURCE KSEOPA 63. UD-3 STA. +.7.' LT CKT. E- -# CKT E- -# GROUND -#6 CKT E- CONST. RAMP F # SERVICE WIRE -# GROUND SERVICE DISCONNECT SUNE S. HERTZ, P.E. TH -#6 CKT E- CONST. EB FRONTAGE ROAD PE No. 6 0 Spring Vista Drive DeBary, FL 37 3 Phone: Fax: CERTIFICATION OF AUTHORIZATION # 73 3 LOAD CENTER E STA. +7.0, 63.7' LT 0/0 VAC UD-3 STA. +3..' RT CKT. E- UD-37 STA ' RT CKT. E- -# CKT E- -# GROUND (TYPICAL) ROAD SR UD-0 STA ' LT CKT. E- COUNTY SEMINOLE TH6 6 6 UD- STA ' RT CKT. E- TH -# CKT E- -# GROUND UD- STA ' LT CKT. E- FINANCIAL PROJECT ID #6 CKT E- UD-3 STA. +..0' LT CKT. E TH7 CONST. SR (WEKIVA PARKWAY) LIGHTING PLAN 0 N 0 Feet L- THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. //07 :3: PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\planlt0
12 GAS SERVICE DISCONNECT ELEC LOAD CENTER F STA. +., 3.' RT 0/0 VAC W ATER GAS W ATER W ATER CONST. ORANGE BOULEVARD N -# CKT F- -# GROUND UD-7 STA ' LT UD-6 STA. +..6' LT -# CKT F- -# GROUND -#6 CKT F- ORANGE AVE. -#6 CKT F- CONST. S. ORANGE AVE UD- STA ' RT UD- STA ' RT W ATER NPW W ATER -#6 CKT F- W ATER UD- STA. +..' LT -# CKT F- -# GROUND UD-0 STA ' LT SR EB UD- STA ' RT -# CKT F- -# GROUND UD- STA ' RT PROPOSED POWER SOURCE -# SERVICE WIRE -# GROUND SR WB CONST. SR (WEKIVA PARKWAY) -#6 CKT F- 7 0 UD- STA ' LT -# CKT F- -# GROUND UD-3 STA ' LT -#6 CKT F- ORANGE BLVD UD- STA ' RT -# CKT F- -# GROUND UD- STA ' RT 7 W ATER UD-6 STA ' LT 6 0 Feet ORANGE BLVD. 0 -# CKT F- -# GROUND -#6 CKT F- UD-7 STA ' LT UD- STA ' RT -# CKT F- -# GROUND UD- STA ' RT END LIGHTING STA THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE LIGHTING PLAN L- //07 :3:00 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\planlt06
13 GAS 3 MA- STA ' LT. POLE No. 3 STA. 3+..' LT POLE No. 36 STA ' LT ORANGE BLVD. MA- STA. +6..' LT POLE No. 37 STA ' RT END LIGHTING N LD POLE No. 0 STA ' LT NOTE: SR 6 3 LC LB LA LUMINAIRES MOUNTED ON MAST ARM ARE DETAILED IN THE SIGNAL PLANS. L- MA- STA. +.6.' RT POLE No. 3 STA ' LT V #6 L- V L-3 L-7 V L- L- V MA-3 STA ' RT -# GROUND PROPOSED POWER SOURCE POLE No. 3 STA ' RT LOAD CENTER G 0/0 VAC SERVICE DISCONNECT -# SERVICE WIRE L6A L6B L6C STA. +7.7,.' RT L6D L6E L6F 0 Feet 0 THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE LIGHTING PLAN L- //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\planlt07
14 EMBEDDED JUNCTION BOX " FLEXIBLE STEEL CONDUIT. (EX. LIQUATITE FLEXIBLE STEEL CONDUIT JIC, ", PART 0" OR APPROVED EQUIVALENT.) NOTES: TO PROPOSED LOAD CENTER. ALL ATTACHMENT HARDWARE SHALL BE 3 STAINLESS STEEL. " RGS TO FLEX-CONDUIT COUPLING PROPOSED PULL BOX. ENSURE ALL ELEMENTS ARE BONDED AND GROUNDED PER NEC REQUIREMENTS. " SCHEDULE 0 PVC CONDUIT " SCHEDULE 0 PVC CONDUIT 3. ALL CONDUIT ATTACHMENTS TO COUPLERS, EQUIPMENT ENCLOSURES (CABINETS), AND PULLING ELBOWS SHALL BE WEATHER TIGHT. STAINLESS STEEL CONDUIT STRAPS ATTACHED WITH MECHANICAL EXPANSION ANCHORS ('-CENTER TO CENTER) " RGS CONDUIT CONTAINING CIRCUITS (SIZE AND NUMBER PER PLAN S) CONDUIT COUPLER PROPOSED MSE WALL THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE UNDER DECK LIGHTING PLANS LIGHTING DETAILS L- //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\cnpllt0.dgn
15 7 Keyed Notes:.. SERVICE POINT DETAIL LOAD CENTER A 0/0V, Single Phase, 3 Wire Electric Distribution Overhead Service Drop. -# AWG Ungrounded Service Conductors & -# AWG ed Service Conductor (Neutral) in " Underground Conduit to item G N Ø Ø 0V Photo Electric Cell 00VA Mercury with Surge Protection for 000V Peak 3. Meter Socket by Contractor NEMA 3R Wire Trough A A 6 ITS Service Disconnect (See ITS Plans for Further Details) ONE LINE DIAGRAM DISTRIBUTION POINT PC SERVICE XFMR SECONDARY 3. SERVICE MAIN DISC. LIGHTING LOAD CENTER VOLTAGE: 0/0 PHASE: WIRES: Service Main Disconnect: 0V, Pole, S/N, 0A,,000 AIC Min. Rated Circuit Breaker, in Service Entrance Rated NEMA X Circuit Breaker Enclosure. Bound Enclosure to ed Conductor (Neutral) with #6 Main Bonding Jumper. Lighting Control Panel Enclosure. Dimensions as Necessary for Equipment Inside. Mounted Cabinet per Index Service Point H-Frame. Point of Service: Utility Company Installed Handhole. Contractor to provide ' of slack service feeder for connection by Utility Company. Main Lug Only Panelboard in NEMA Enclosure. Number and Rating of Branch Circuit Breakers shall be as Indicated on Panelboard Schedule. Branch Circuit to Roadway Luminaires in " Underground Conduit (See plan sheets for count of conduits).. ƅ" x 0" Min. Copper Clad Rod (Electrode). Extend or Add Additional Bonded with # AWG Tin Plated Bare Copper Wire to Achieve Ohms or Less Resistance to. A. ƅ" Copper Clad Rod, 0' Long.. # Insulated Copper Wire (Common). Bond the Service Neutral to in Wire Trough at Neutral Bus. Refer to ITS Plans for Further Detail. A. #6 Insultated Copper Wire.. Fused Control Circuit, 0VAC. Size conductors according to contactor manufactures recommendation, and size fuse per NEC.. Lightning Arrester (Surge Protective Device) Mounted on Outside of Enclosure.. Lighting Control Panel Main Breaker in NEMA Enclosure: 0V, Pole, S/N, 60A,,000 AIC Min. Rated. Pole Electrically Held Feeder Disconnect Style Lighting Contactor in NEMA Enclosure: Minimum Voltage and Current Rating to Meet Lighting Control Panel Main Breaker, 0VAC 60Hz Coil. Photo Electric Switch-0V Rated. 7. Hand-off Automatic Selector Switch (Part of Lighting Contactor). Concrete Pad.. Underground Feeder: 3-# & -#6 in " Underground Conduit 0. Mount on Service Point H-Frame.. BUS. AVAILABLE BOLTED FAULT CURRENT AT EQUIPMENT (KA) P.E. Controller Cut a " hole in the side of the Lighting Control Panel enclosure for the operation and mounting of the P.E. controller. Use plexiglass and a clear silicone sealant to cover hole, install P.E. Controller. PHOTO ELECTRIC CONTROLLER DETAIL PANELBOARD SCHEDULE. All equipment shall be enclosed individual NEMA Enclosures inside of the NEMA X Lighting Control Panel Enclosure. All wiring between these enclosures shall be installed in Intermediate Metal Conduit. Side or Back of Enclosure. Shop Drawings are required for all equipment associated with the Lighting Control Panel. CKT CKT NAME CONNECTED LOAD TRIP POLES A LOAD (VA) B LOAD (VA) POLES TRIP CKT NAME CONNECTED LOAD CKT A- LED LUMINARIES 0 A LOAD PER LEG: TOTAL LOAD (VA): TOTAL 0V: " 66 A Notes: #6 AWG Bonding Jumper #6 AWG EGC Neutral Bus A Circuit Circuit MAINS TYPE: LUG MAINS RAITING: 0 A AIC:,000 A 3 NEMA Contactor Enclosure 7 TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL 6 Bus A A To Service Main Disconnect RISER DIAGRAM - TYPICAL DISTRIBUTION POINT H A OFF Circuit Circuit Circuit Circuit THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE SERVICE POINT DETAIL LIGHTING PLANS LOAD CENTER A L- //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\SRPTLT0.dgn
16 SERVICE POINT DETAIL LOAD CENTER B 7 Keyed Notes:. 0/0V, Single Phase, 3 Wire Electric Distribution Underground Service Drop. to item G N Ø Ø 0V Photo Electric Cell 00VA Mercury with Surge Protection for 000V Peak # AWG Ungrounded Service Conductors & -# AWG ed Service Conductor (Neutral) in " Underground Conduit Meter Socket by Contractor Service Main Disconnect: 0V, Pole, S/N, 0A,,000 AIC Min. Rated Circuit Breaker, in Service Entrance Rated NEMA X Circuit Breaker Enclosure Lighting Control Panel Enclosure. Dimensions as Necessary for Equipment Inside. Mounted Cabinet per Index Concrete Riser Pole. #6 AWG Bonding Jumper NEMA Contactor Enclosure H A 0 PC ONE LINE DIAGRAM DISTRIBUTION POINT SERVICE XFMR SECONDARY 3. SERVICE MAIN DISC. LIGHTING LOAD CENTER VOLTAGE: 0/0 PHASE: WIRES: Point of Service: Utility Company Installed Handhole. Contractor to provide ' of slack service feeder for connection by Utility Company. Main Lug Only Panelboard in NEMA Enclosure. Number and Rating of Branch Circuit Breakers shall be as Indicated on Panelboard Schedule. Branch Circuit to Roadway Luminaires in " Underground Conduit (See plan sheets for count of conduits).. ƅ" Copper Clad Rod, 0' Long.. #6 Insulated Copper Wire. Bond the Service Neutral to at Service Main Disconnect.. Fused Control Circuit, 0VAC. Size conductors according to contactor manufactures recommendation, and size fuse per NEC.. Lightning Arrester (Surge Protective Device) Mounted on Outside of Enclosure.. Lighting Control Panel Main Breaker in NEMA Enclosure: 0V, Pole, S/N, 60A,,000 AIC Min. Rated. Pole Electrically Held Feeder Disconnect Style Lighting Contactor in NEMA Enclosure: Minimum Voltage and Current Rating to Meet or Exceed Lighting Control Panel Main Breaker, 0VAC 60Hz Coil. Photo Electric Switch-0V Rated. 7. Hand-off Automatic Selector Switch (Part of Lighting Contactor). Concrete Pad.. Underground Feeder: 3-# & -#6 in " Underground Conduit 0. Mount on Riser Pole.. BUS. AVAILABLE BOLTED FAULT CURRENT AT EQUIPMENT (KA).. P.E. Controller PHOTO ELECTRIC CONTROLLER DETAIL PANELBOARD SCHEDULE. All equipment shall be enclosed individual NEMA Enclosures inside of the NEMA X Lighting Control Panel Enclosure. All wiring between these enclosures shall be installed in Intermediate Metal Conduit. CKT CKT NAME CONNECTED LOAD TRIP POLES A LOAD (VA) B LOAD (VA) POLES TRIP CKT NAME CONNECTED LOAD CKT B- LED LUMINARIES 0 A LOAD PER LEG: TOTAL LOAD (VA): TOTAL 0V: Side or Back of Enclosure Cut a " hole in the side of the Lighting Control Panel enclosure for the operation and mounting of the P.E. controller. Use plexiglass and a clear silicone sealant to cover hole, install P.E. Controller. " #6 AWG EGC Neutral Bus. Notes: Circuit Circuit Shop Drawings are required for all equipment associated with the Lighting Control Panel. MAINS TYPE: LUG MAINS RAITING: 0 A AIC:,000 A 3 7 TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL 6 Bus OFF Circuit Circuit Circuit Circuit To Service Main Disconnect RISER DIAGRAM - TYPICAL DISTRIBUTION POINT THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE SERVICE POINT DETAIL LIGHTING PLANS LOAD CENTER B L- //07 :3:03 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\SRPTLT03.dgn
17 7 0 Keyed Notes:.. SERVICE POINT DETAIL LOAD CENTER C 0/0V, Single Phase, 3 Wire Electric Distribution Overhead Service Drop. -# AWG Ungrounded Service Conductors & -# AWG ed Service Conductor (Neutral) in " Underground Conduit to item G N Ø Ø 0V Photo Electric Cell 00VA Mercury with Surge Protection for 000V Peak 3. Meter Socket by Contractor NEMA 3R Wire Trough A A 6 ITS Service Disconnect (See ITS Plans for Further Details) ONE LINE DIAGRAM DISTRIBUTION POINT PC SERVICE XFMR SECONDARY 3. SERVICE MAIN DISC.. ƅ" x 0" Min. Copper Clad Rod (Electrode). Extend or Add Additional Bonded with # AWG Tin Plated Bare Copper Wire to Achieve Ohms or Less Resistance to. A. ƅ" Copper Clad Rod, 0' Long.. # Insulated Copper Wire (Common). Bond the Service Neutral to in Wire Trough at Neutral Bus. Refer to ITS Plans for Further Detail. A. #6 Insultated Copper Wire.. Fused Control Circuit, 0VAC. Size conductors according to contactor manufactures recommendation, and size fuse per NEC.. Lightning Arrester (Surge Protective Device) Mounted on Outside of Enclosure.. Lighting Control Panel Main Breaker in NEMA Enclosure: 0V, Pole, S/N, 60A,,000 AIC Min. Rated. Pole Electrically Held Feeder Disconnect Style Lighting Contactor in NEMA Enclosure: Minimum Voltage and Current Rating to Meet Lighting Control Panel Main Breaker, 0VAC 60Hz Coil. Photo Electric Switch-0V Rated. 7. Hand-off Automatic Selector Switch (Part of Lighting Contactor). Concrete Pad.. Underground Feeder: 3-# & -#6 in " Underground Conduit 0. Mount on Service Point H-Frame.. BUS. LIGHTING LOAD CENTER Service Main Disconnect: 0V, Pole, S/N, 0A,,000 AIC Min. Rated Circuit Breaker, in Service Entrance Rated NEMA X Circuit Breaker Enclosure. Bound Enclosure to ed Conductor (Neutral) with #6 Main Bonding Jumper. Lighting Control Panel Enclosure. Dimensions as Necessary for Equipment Inside. Mounted Cabinet per Index Service Point H-Frame. Point of Service: Utility Company Installed Handhole. Contractor to provide ' of slack service feeder for connection by Utility Company. Main Lug Only Panelboard in NEMA Enclosure. Number and Rating of Branch Circuit Breakers shall be as Indicated on Panelboard Schedule. Branch Circuit to Roadway Luminaires in " Underground Conduit (See plan sheets for count of conduits). AVAILABLE BOLTED FAULT CURRENT AT EQUIPMENT (KA) VOLTAGE: 0/0 PHASE: WIRES: 3..7 P.E. Controller Cut a " hole in the side of the Lighting Control Panel enclosure for the operation and mounting of the P.E. controller. Use plexiglass and a clear silicone sealant to cover hole, install P.E. Controller. PHOTO ELECTRIC CONTROLLER DETAIL PANELBOARD SCHEDULE. All equipment shall be enclosed individual NEMA Enclosures inside of the NEMA X Lighting Control Panel Enclosure. All wiring between these enclosures shall be installed in Intermediate Metal Conduit. Side or Back of Enclosure. Shop Drawings are required for all equipment associated with the Lighting Control Panel. CKT CKT NAME CONNECTED LOAD TRIP POLES A LOAD (VA) B LOAD (VA) POLES TRIP CKT NAME CONNECTED LOAD CKT C- LED LUMINARIES 0 A LOAD PER LEG: TOTAL LOAD (VA): TOTAL 0V: " 0 A Notes: #6 AWG Bonding Jumper #6 AWG EGC Neutral Bus A Circuit Circuit MAINS TYPE: LUG MAINS RAITING: 0 A AIC:,000 A 3 NEMA Contactor Enclosure 7 TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL 6 Bus A A To Service Main Disconnect RISER DIAGRAM - TYPICAL DISTRIBUTION POINT H A OFF Circuit Circuit Circuit Circuit THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE SERVICE POINT DETAIL LIGHTING PLANS LOAD CENTER C L-7 //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\SRPTLT0.dgn
18 SERVICE POINT DETAIL LOAD CENTER D 7 0 Keyed Notes:. 0/0V, Single Phase, 3 Wire Electric Distribution Underground Service Drop. to item G N Ø Ø 0V Photo Electric Cell 00VA Mercury with Surge Protection for 000V Peak # AWG Ungrounded Service Conductors & -# AWG ed Service Conductor (Neutral) in " Underground Conduit Meter Socket by Contractor Service Main Disconnect: 0V, Pole, S/N, 0A,,000 AIC Min. Rated Circuit Breaker, in Service Entrance Rated NEMA X Circuit Breaker Enclosure Lighting Control Panel Enclosure. Dimensions as Necessary for Equipment Inside. Mounted Cabinet per Index Concrete Riser Pole. #6 AWG Bonding Jumper NEMA Contactor Enclosure H A 0 PC ONE LINE DIAGRAM DISTRIBUTION POINT ƅ" Copper Clad Rod, 0' Long.. #6 Insulated Copper Wire. Bond the Service Neutral to at Service Main Disconnect.. Fused Control Circuit, 0VAC. Size conductors according to contactor manufactures recommendation, and size fuse per NEC.. Lightning Arrester (Surge Protective Device) Mounted on Outside of Enclosure.. Lighting Control Panel Main Breaker in NEMA Enclosure: 0V, Pole, S/N, 60A,,000 AIC Min. Rated. Pole Electrically Held Feeder Disconnect Style Lighting Contactor in NEMA Enclosure: Minimum Voltage and Current Rating to Meet or Exceed Lighting Control Panel Main Breaker, 0VAC 60Hz Coil. Photo Electric Switch-0V Rated. 7. Hand-off Automatic Selector Switch (Part of Lighting Contactor). Concrete Pad.. Underground Feeder: 3-# & -#6 in " Underground Conduit 0. Mount on Riser Pole.. BUS. SERVICE XFMR SECONDARY 3. SERVICE MAIN DISC. LIGHTING LOAD CENTER Point of Service: Utility Company Installed Handhole. Contractor to provide ' of slack service feeder for connection by Utility Company. Main Lug Only Panelboard in NEMA Enclosure. Number and Rating of Branch Circuit Breakers shall be as Indicated on Panelboard Schedule. Branch Circuit to Roadway Luminaires in " Underground Conduit (See plan sheets for count of conduits). AVAILABLE BOLTED FAULT CURRENT AT EQUIPMENT (KA) VOLTAGE: 0/0 PHASE: WIRES: 3.. P.E. Controller PHOTO ELECTRIC CONTROLLER DETAIL PANELBOARD SCHEDULE. All equipment shall be enclosed individual NEMA Enclosures inside of the NEMA X Lighting Control Panel Enclosure. All wiring between these enclosures shall be installed in Intermediate Metal Conduit.. Shop Drawings are required for all equipment associated with the Lighting Control Panel. CKT CKT NAME CONNECTED LOAD TRIP POLES A LOAD (VA) B LOAD (VA) POLES TRIP CKT NAME CONNECTED LOAD CKT D- LED LUMINARIES 0 A LOAD PER LEG: TOTAL LOAD (VA): TOTAL 0V: Side or Back of Enclosure Cut a " hole in the side of the Lighting Control Panel enclosure for the operation and mounting of the P.E. controller. Use plexiglass and a clear silicone sealant to cover hole, install P.E. Controller. " #6 AWG EGC Neutral Bus Notes: Circuit Circuit MAINS TYPE: LUG MAINS RAITING: 0 A AIC:,000 A 3 7 TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL 6 Bus OFF Circuit Circuit Circuit Circuit To Service Main Disconnect RISER DIAGRAM - TYPICAL DISTRIBUTION POINT THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE SERVICE POINT DETAIL LIGHTING PLANS LOAD CENTER D L- //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\SRPTLT0.dgn
19 SERVICE POINT DETAIL LOAD CENTER E 7 Keyed Notes:. 0/0V, Single Phase, 3 Wire Electric Distribution Underground Service Drop. to item G N Ø Ø 0V Photo Electric Cell 00VA Mercury with Surge Protection for 000V Peak # AWG Ungrounded Service Conductors & -# AWG ed Service Conductor (Neutral) in " Underground Conduit Meter Socket by Contractor Service Main Disconnect: 0V, Pole, S/N, 0A,,000 AIC Min. Rated Circuit Breaker, in Service Entrance Rated NEMA X Circuit Breaker Enclosure Lighting Control Panel Enclosure. Dimensions as Necessary for Equipment Inside. Mounted Cabinet per Index Concrete Riser Pole. #6 AWG Bonding Jumper NEMA Contactor Enclosure H A 0 PC ONE LINE DIAGRAM DISTRIBUTION POINT SERVICE XFMR SECONDARY 3. SERVICE MAIN DISC. LIGHTING LOAD CENTER VOLTAGE: 0/0 PHASE: WIRES: Point of Service: Utility Company Installed Handhole. Contractor to provide ' of slack service feeder for connection by Utility Company. Main Lug Only Panelboard in NEMA Enclosure. Number and Rating of Branch Circuit Breakers shall be as Indicated on Panelboard Schedule. Branch Circuit to Roadway Luminaires in " Underground Conduit (See plan sheets for count of conduits).. ƅ" Copper Clad Rod, 0' Long.. #6 Insulated Copper Wire. Bond the Service Neutral to at Service Main Disconnect.. Fused Control Circuit, 0VAC. Size conductors according to contactor manufactures recommendation, and size fuse per NEC.. Lightning Arrester (Surge Protective Device) Mounted on Outside of Enclosure.. Lighting Control Panel Main Breaker in NEMA Enclosure: 0V, Pole, S/N, 60A,,000 AIC Min. Rated. Pole Electrically Held Feeder Disconnect Style Lighting Contactor in NEMA Enclosure: Minimum Voltage and Current Rating to Meet or Exceed Lighting Control Panel Main Breaker, 0VAC 60Hz Coil. Photo Electric Switch-0V Rated. 7. Hand-off Automatic Selector Switch (Part of Lighting Contactor). Concrete Pad.. Underground Feeder: 3-# & -#6 in " Underground Conduit 0. Mount on Riser Pole.. BUS. AVAILABLE BOLTED FAULT CURRENT AT EQUIPMENT (KA) P.E. Controller PHOTO ELECTRIC CONTROLLER DETAIL PANELBOARD SCHEDULE. All equipment shall be enclosed individual NEMA Enclosures inside of the NEMA X Lighting Control Panel Enclosure. All wiring between these enclosures shall be installed in Intermediate Metal Conduit. CKT CKT NAME CONNECTED LOAD TRIP POLES A LOAD (VA) B LOAD (VA) POLES TRIP CKT NAME CONNECTED LOAD CKT E- LED LUMINARIES 0 A LOAD PER LEG: TOTAL LOAD (VA): TOTAL 0V: Side or Back of Enclosure Cut a " hole in the side of the Lighting Control Panel enclosure for the operation and mounting of the P.E. controller. Use plexiglass and a clear silicone sealant to cover hole, install P.E. Controller. " #6 AWG EGC Neutral Bus. Notes: Circuit Circuit Shop Drawings are required for all equipment associated with the Lighting Control Panel. MAINS TYPE: LUG MAINS RAITING: 0 A AIC:,000 A 3 7 TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL 6 Bus OFF Circuit Circuit Circuit Circuit To Service Main Disconnect RISER DIAGRAM - TYPICAL DISTRIBUTION POINT THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE SERVICE POINT DETAIL LIGHTING PLANS LOAD CENTER E L- //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\SRPTLT06.dgn
20 SERVICE POINT DETAIL LOAD CENTER F 7 0 Keyed Notes:. 0/0V, Single Phase, 3 Wire Electric Distribution Underground Service Drop. to item G N Ø Ø 0V Photo Electric Cell 00VA Mercury with Surge Protection for 000V Peak # AWG Ungrounded Service Conductors & -# AWG ed Service Conductor (Neutral) in " Underground Conduit Meter Socket by Contractor Service Main Disconnect: 0V, Pole, S/N, 0A, 3,000 AIC Min. Rated Circuit Breaker, in Service Entrance Rated NEMA X Circuit Breaker Enclosure Lighting Control Panel Enclosure. Dimensions as Necessary for Equipment Inside. Mounted Cabinet per Index Concrete Riser Pole. #6 AWG Bonding Jumper NEMA Contactor Enclosure H A 0 PC ONE LINE DIAGRAM DISTRIBUTION POINT SERVICE XFMR SECONDARY 3. SERVICE MAIN DISC. LIGHTING LOAD CENTER VOLTAGE: 0/0 PHASE: WIRES: Point of Service: Utility Company Installed Handhole. Contractor to provide ' of slack service feeder for connection by Utility Company. Main Lug Only Panelboard in NEMA Enclosure. Number and Rating of Branch Circuit Breakers shall be as Indicated on Panelboard Schedule. Branch Circuit to Roadway Luminaires in " Underground Conduit (See plan sheets for count of conduits).. ƅ" Copper Clad Rod, 0' Long.. #6 Insulated Copper Wire. Bond the Service Neutral to at Service Main Disconnect.. Fused Control Circuit, 0VAC. Size conductors according to contactor manufactures recommendation, and size fuse per NEC.. Lightning Arrester (Surge Protective Device) Mounted on Outside of Enclosure.. Lighting Control Panel Main Breaker in NEMA Enclosure: 0V, Pole, S/N, 60A,,000 AIC Min. Rated. Pole Electrically Held Feeder Disconnect Style Lighting Contactor in NEMA Enclosure: Minimum Voltage and Current Rating to Meet or Exceed Lighting Control Panel Main Breaker, 0VAC 60Hz Coil. Photo Electric Switch-0V Rated. 7. Hand-off Automatic Selector Switch (Part of Lighting Contactor). Concrete Pad.. Underground Feeder: 3-# & -#6 in " Underground Conduit 0. Mount on Riser Pole.. BUS. AVAILABLE BOLTED FAULT CURRENT AT EQUIPMENT (KA) 0.. P.E. Controller PHOTO ELECTRIC CONTROLLER DETAIL PANELBOARD SCHEDULE CKT CKT NAME CONNECTED LOAD TRIP POLES A LOAD (VA) B LOAD (VA) POLES TRIP CKT NAME CONNECTED LOAD CKT F- LED LUMINARIES 0 A LOAD PER LEG: TOTAL LOAD (VA): TOTAL 0V: Side or Back of Enclosure Cut a " hole in the side of the Lighting Control Panel enclosure for the operation and mounting of the P.E. controller. Use plexiglass and a clear silicone sealant to cover hole, install P.E. Controller. " #6 AWG EGC Neutral Bus. All equipment shall be enclosed individual NEMA Enclosures inside of the NEMA X Lighting Control Panel Enclosure. All wiring between these enclosures shall be installed in Intermediate Metal Conduit.. Notes: Circuit Circuit Shop Drawings are required for all equipment associated with the Lighting Control Panel. MAINS TYPE: LUG MAINS RAITING: 0 A AIC:,000 A 3 7 TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL 6 Bus OFF Circuit Circuit Circuit Circuit To Service Main Disconnect RISER DIAGRAM - TYPICAL DISTRIBUTION POINT THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE SERVICE POINT DETAIL LIGHTING PLANS LOAD CENTER F L-0 //07 :3:0 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\SRPTLT07.dgn
21 SERVICE POINT DETAIL LOAD CENTER G 7 0 Keyed Notes:. 0/0V, Single Phase, 3 Wire Electric Distribution Underground Service Drop. to item G N Ø Ø 0V Photo Electric Cell 00VA Mercury with Surge Protection for 000V Peak # AWG Ungrounded Service Conductors & -# AWG ed Service Conductor (Neutral) in " Underground Conduit Meter Socket by Contractor Service Main Disconnect: 0V, Pole, S/N, 0A,,000 AIC Min. Rated Circuit Breaker, in Service Entrance Rated NEMA X Circuit Breaker Enclosure Lighting Control Panel Enclosure. Dimensions as Necessary for Equipment Inside. Mounted Cabinet per Index Concrete Riser Pole. #6 AWG Bonding Jumper NEMA Contactor Enclosure H A 0 PC ONE LINE DIAGRAM DISTRIBUTION POINT SERVICE XFMR SECONDARY 3. SERVICE MAIN DISC. LIGHTING LOAD CENTER VOLTAGE: 0/0 PHASE: WIRES: Point of Service: Utility Company Installed Handhole. Contractor to provide ' of slack service feeder for connection by Utility Company. Main Lug Only Panelboard in NEMA Enclosure. Number and Rating of Branch Circuit Breakers shall be as Indicated on Panelboard Schedule. Branch Circuit to Roadway Luminaires in " Underground Conduit (See plan sheets for count of conduits).. ƅ" Copper Clad Rod, 0' Long.. #6 Insulated Copper Wire. Bond the Service Neutral to at Service Main Disconnect.. Fused Control Circuit, 0VAC. Size conductors according to contactor manufactures recommendation, and size fuse per NEC.. Lightning Arrester (Surge Protective Device) Mounted on Outside of Enclosure.. Lighting Control Panel Main Breaker in NEMA Enclosure: 0V, Pole, S/N, 60A,,000 AIC Min. Rated. Pole Electrically Held Feeder Disconnect Style Lighting Contactor in NEMA Enclosure: Minimum Voltage and Current Rating to Meet or Exceed Lighting Control Panel Main Breaker, 0VAC 60Hz Coil. Photo Electric Switch-0V Rated. 7. Hand-off Automatic Selector Switch (Part of Lighting Contactor). Concrete Pad.. Underground Feeder: 3-# & -#6 in " Underground Conduit 0. Mount on Riser Pole.. BUS. AVAILABLE BOLTED FAULT CURRENT AT EQUIPMENT (KA)..7 P.E. Controller PHOTO ELECTRIC CONTROLLER DETAIL PANELBOARD SCHEDULE MAINS TYPE: LUG AIC:,000 A CKT CKT NAME CONNECTED LOAD TRIP POLES A LOAD (VA) B LOAD (VA) POLES TRIP CKT NAME CONNECTED LOAD CKT G- LED LUMINARIES 0 A LOAD PER LEG: TOTAL LOAD (VA): 63 6 TOTAL 0V:.0 63 Side or Back of Enclosure Cut a " hole in the side of the Lighting Control Panel enclosure for the operation and mounting of the P.E. controller. Use plexiglass and a clear silicone sealant to cover hole, install P.E. Controller. " #6 AWG EGC Neutral Bus. All equipment shall be enclosed individual NEMA Enclosures inside of the NEMA X Lighting Control Panel Enclosure. All wiring between these enclosures shall be installed in Intermediate Metal Conduit.. Notes: Circuit Circuit Shop Drawings are required for all equipment associated with the Lighting Control Panel. MAINS RAITING: 0 A 3 7 TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL 6 Bus OFF Circuit Circuit Circuit Circuit To Service Main Disconnect RISER DIAGRAM - TYPICAL DISTRIBUTION POINT THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 6G-3.00, F.A.C. SUNE S. HERTZ, P.E. PE No. 6 0 Spring Vista Drive Phone: DeBary, FL 37 Fax: CERTIFICATION OF AUTHORIZATION # 73 ROAD COUNTY FINANCIAL PROJECT ID SR SEMINOLE SERVICE POINT DETAIL LIGHTING PLANS LOAD CENTER G L- //07 :3:06 PM Z:\0 Projects\ (Wekiva Parkway-Section 7A)\CADD\0000\lighting\srptlt0.dgn
DEPARTMENT OF TRANSPORTATION
THIS PROJECT TO BE LET TO CONTRACT WITH FINANCIAL PROJECT ID 3875-3-5-0 CHIPLEY 0 95 75 TALLAHASSEE PENSACOLA CONTRACT PLANS JACKSONVILLE 0 FORT WALTON BEACH 95 PANAMA CITY CITY ST AUGUSTINE GAINESVILLE
More informationFor Conduit Inspections
Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationROADWAY LIGHTING SYSTEMS (2545)
GENERAL LIGHTING MATERIAL REQUIREMENTS General material requirements must be in accordance with MnDOT 2545.2. SERVICE CABINETS 3850 Lighting service cabinets Type L1, Type L2, Type A, Type B, and Type
More information1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX
LAD05-9, CA 964 TITLE SHEET LAD05-9 SHEET INDEX 00 DEXTER AVE. SUITE 50 SEATTLE, WA 9809 PROJECT SUMMARY PROJECT DESCRIPTION COORDINATES LATITUDE: 33.678084 N LONGITUDE: -7.84858 W 0640 Sepulveda Blvd.
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationPentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION
PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationTHREE PHASE WIRING SPECIFICATIONS
THREE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More informationSINGLE PHASE WIRING SPECIFICATIONS
SINGLE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016
UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More informationRESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS
SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationCHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More informationELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016
DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationVolume 2 Charts, Formulas, and Other Useful Information
Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase
More informationSALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL
SALEM CITY POWER DEPARTMENT TABLE OF CONTENTS Section 1 General Requirements Purpose...1.1 Codes and Ordinances...1.1 Changes or Conflicts in Requirements and Guidelines...1.1 Application for Service...1.2
More informationCOMMERCIAL QUICK REFERENCE
COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR
More informationA. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.
16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to
More informationCustomer Requirements Downtown Secondary Network Service
Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard
More informationNEC 2011 Code Changes
NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL
INTRODUCTION This policy has been adopted by the Board of Public Works as a guide to obtaining electric service and to set forth the services available, conditions for service, and standards for materials
More informationAPPENDIX B: LISTS OF APPROVED MATERIALS
APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete
More informationAREA OF WORK ENERGY
THIS DOCUMENT CONTAINS PROPRIETARY 408-859-545 AREA OF WORK THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25SM Controllers Chlorking & CO-2 controlled by chemical controller 3 x Chlorking Cells, 25
More informationNew Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI
New Service Guidelines and Diagrams From... BARRON www.barronelectric.com email: janderson@barronelectric.com Barron Office: P.O. Box 40 Barron, WI 54812-0040 Spooner Office: P.O. Box 261 Spooner, WI 54801-0261
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More information2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code
2. DEFINITIONS 2.1 ACCEPTABLE Acceptable to the Company. 2.2 ADVANCED METER A meter that is capable of remote reading, and is capable of storing electric consumption data at specified time intervals of
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More information34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE
4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER
More informationUNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.
UNDERGROUND SERVCE tems to consider f your trenching route has to be dug by hand, or if a cable must be installed under a paved surface, additional charges apply. f your service cable has to be moved later
More informationMetering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS
Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards
More informationCustomer Requirements Meter Socket Configurations
Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More information7 Single Family Service
7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationBID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT
BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT The County of Hancock, Maine is seeking bids from qualified firms for the purchase and installation of at least a 20KW backup generator
More informationBUSWAY Low Voltage (Pow-R-Flex)
BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and
More informationTable of Contents. Electrical Service Requirements. 1. General Requirements
Table of Contents 1. General Requirements 1.1 General Definition.................................................... 1 1 1.2 Booklet Purpose and Organization....................................... 1-1
More information7. Residential Single-Family and Duplex Buildings (Dwellings)
Sin g le -F a mily a n d Du p le x Bu ild in g s 2016 Electric Service Requirements, 2 nd Edition Section 7 Section 7 Residential Single-Family and Duplex Buildings (Dwellings) Directory Page 7.1 General
More informationParkland Light & Water Co. ELECTRIC SERVICE REQUEST AND METER STANDARDS
Parkland Light & Water Co. ELECTRIC SERVICE REQUEST AND METER STANDARDS Revised: January, 2017 Contents SERVICE REQUEST FORMS RECEIPT OF ELECTRIC SERVICE REQUEST AND METER STANDARDS ELECTRIC SERVICE REQUEST
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD
ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD CONTROL PANEL MOUNTING PAGE No. 74 NUMBER: LS-240V1PH-TCU-VFD 35 38 47 U A 9 33 V 26 24 25 41 43 7 7 44 ALUMINUM BACKPLATE 41 42 50 46
More informationSection 02: Pre-Installation Procedures
Section 02: Pre-Installation Procedures Foundation! WARNING The MUST be placed on a surface that will support the combined weight of the, options, fixtures, and tooling, etc. (refer to the Specifications
More informationSPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL
1 POWER DEPARTMENT EFFECTIVE AS OF FEBRUARY 1, 2008, REVISED JULY 1, 2013 STANDARDS ARE SUBJECT TO REVIEW Table of Contents 2 TABLE OF CONTENTS Section 1 General Requirements Purpose...1.1 Codes and Ordinances...1.1
More informationMetering and Service Installation:
Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...
More informationApproved Contractor Construction e-guide Residential Commercial
Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13
More informationInstalling or Rebuilding Your Electric Service
Installing or Rebuilding Your Electric Service 2 3 Contents Policies for New and Rebuilt Electric Service 2-4 Paperwork and fees...2 Five-year policy...3 Proposed route location and conditions...3 Construction
More informationRESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS SECTION II RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS
SECTION II This section discusses the City of Palo Alto's requirements for establishing electric service to new or upgraded residential installations. The same requirements apply to both underground and
More informationMeter Installation. -and- Padmount Transformer Guide
Meter Installation -and- Padmount Transformer Guide Feb. 2016 METERING REQUIREMENTS The following information shall be used as a guide for installing metering equipment. A self-contained meter has all
More informationNEW SERVICE HANDBOOK COMMERCIAL & IRRIGATION SUPPLEMENT
NEW SERVICE HANDBOOK COMMERCIAL & IRRIGATION SUPPLEMENT Meter Installations There are three basic ways to measure electricity consumption: Small and medium services are metered directly using direct connect
More informationLee County DOT Traffic Section Design Standard for Sign Installation
Lee County DOT Traffic Section Design Standard for Sign Installation Traffic Section Table Of Contents Section Title 1. Sign Panel Material 2. Sign Shape 3. Posts 4. Fasteners 5. Retro reflectivity and
More informationQuik-Spec Coordination Panelboard Specifications
Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY
More informationGENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" TYP DH-108
MATCH NE SEE SHEET E. N DH-6 DH-7 DH-9 DH-9 DH-8 DH-6 DH-8 MATCH NE SEE SHEET E. GENERAL NOTES KE PLAN NTS 407 North st Street, Suite 0 (5) 96-050 Fax (5) 96-06 N MATCH NE SEE SHEET E. DH- DH- DH- DH-7
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationSECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems
COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More information10. METERING General Requirements
10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationOutdoor Power Transmission & Distribution
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards and requirements for Outdoor Power Transmission and Distribution, including but not limited to the following:
More information3.1 Overview of ATCO Electric s URD System Design
Page: 3-1 3.0 URD DESIGN GUIDELINES 3.1 Overview of ATCO Electric s URD System Design The power supply to all single lot underground residential services is through front lot service. Single phase transformers
More informationDUNKIN DONUTS 206 EAST STATE STREET GENEVA, ILLINOIS
PRELIMINARY ENGINEERING PLANS DUNKIN DONUTS 206 EAST STATE STREET GENEVA, ILLINOIS ERIC CARLSON ARCHITECTS LOCATION MAP DRAWINGS INDE CONTACTS REV DATE NOT TO SCALE BENCHMARKS CRISSEY AVENUE IL ROUTE 38
More informationENTRANCE EQUIPMENT ER D PAGE 1 OF 5
PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument
More informationWARREN COUNTY, N.Y. M/E REFERENCE
SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE
More informationNew Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications
CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT New Panelboard for Lot H, EV Charger Energization, Las Positas College Scope of Work and Technical Specifications Chabot-Las Positas Community College District
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationRCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel
RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the
More informationSPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL
POWER DEPARTMENT EFFECTIVE AS OF FEBRUARY 1, 2008, REVISED JULY 1, 2013 STANDARDS ARE SUBJECT TO REVIEW TABLE OF CONTENTS Section 1 General Requirements Purpose...1.1 Codes and Ordinances...1.1 Changes
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSpring Test 10 due 05/11/2013
Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE N.J. Specification No. Effective Date: July 1, 2001 New Jersey
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More informationCommercial & Industrial
The Empire District Electric Company Requirements For Electric Service And Meter Installations Commercial & Industrial (800) 206 2300 The latest revision of this book can be found at www.empiredistrict.com
More informationRevised: April 2018 ¹ SERVICE TO WIRELESS DEVICE ANTENNA ATTACHMENTS ON CUSTOMER SERVICE POLES (SHEET 1) CUSTOMER: 1. An overcurrent protective device including a disconnect switch shall
More informationThe Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.
SUMMARY This bulletin introduces a new PG&E program that allows the installation of an electric meter socket adapter that will accept a wired connection directly from a residential customer s Photo Voltaic
More informationTransmission & Distribution Glossary of Electrical Terms
Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationA. This section includes unit capacitors for power factor correction.
PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02
More informationCole Service Building Boiler Replacement. Issued for Bidding and Construction August 30, 2012 Project Number G120270CD GENERAL ABBREVIATIONS
CITY OF OXFORD BUTLER COUNTY, OHIO OHIO VICINITY MAP MIAMI UNIVERSITY COLE SERVICE BUILDING BOILER REPLACEMENT CITY OF OXFORD, BULTER COUNTY, OHIO Issued for Bidding and Construction August 30, 2012 Project
More information12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12
Ed Hydro Rain. 12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12 The HRM-12 is a 12 station controller that can be set to water from twenty-four times a day to once every two weeks.
More informationSECTION 300 OVERHEAD SERVICE
SECTION 300 OVERHEAD SERVICE 300.01 General Company provides, installs, and maintains service drop to point of delivery approved by Company. Customer provides point of attachment which is acceptable to
More informationSTOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION
CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.
More informationA. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.
PART 1: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I recently installed a 45-KVA transformer, 480-volt primary
More information