WATER TRAP EQAZ-08-01, EQAZ-08-02

Size: px
Start display at page:

Download "WATER TRAP EQAZ-08-01, EQAZ-08-02"

Transcription

1 8644 GB WATER TRAP EQAZ-08-01, EQAZ-08-02» INSTALLATION AND MAINTENANCE EQAZ WATER TRAP DESIGNED FOR PRESSURE BELOW ATMOSPHERIC INSTALLATION Air handling units with the following: EQRC RECUTERM Plate heat exchanger EQRG eq plate Counter flow plate heat exchanger EQRF Ecoterm Liquid-coupled heat exchanger EQRH Plate heat exchanger EQQA Humidifier EQQB Humidifier EQNN Air cooler EQNP Air cooler are equipped with a drain connection on the inspection side for connection of a water trap. NOTE! EQAZ-08-1 Not designed for pressure above atmospheric. EQAZ-08-2 Not designed for pressure under atmospheric Dimensions EQAZ EQAZ-08-2 WATER TRAP DESIGNED FOR PRESSURE ABOVE ATMOSPHERIC L H Pa Capacity: 0.8 m 3 /h. Under pressure Pa Cut to size (L) Height (H) < mm 40 mm mm 60 mm mm 100 mm mm 140 mm mm 180 mm mm 220 mm INSTALLATION Fit the water trap without the use of tools as shown in the figure above and in the following order: A. Connect the elbow 2 to the drain pipe 1. B. Connect the discharge pipe 1 (32 mm o.d.) to the watertrap outlet 6. The discharge pipe should be as short as possible and should be run with a continuous incline to a floor gully, without reduction in area. A clear space of at least 150 mm is required below the unit for the water trap. 1. Drain pipe of the unit section. 2. Elbow. 3. Base frame or other support with a height of at least 150 mm. 4. U-bend mm i.d. outlet with compression coupling. 6. Floor gully. 7. Non-return valve with cleaning cover.

2 Installation and maintenance instruction 2 CLEANING THE WATER TRAP The water trap must be unscrewed and re-assembled by hand. Check that the pipes/hoses are not blocked and cleanany dirt and deposits from the water trap. C 0 MAINTENANCE INTERVAL 6 months. Check and clean the water trap. N.B. The water trap and discharge pipe must not be subjected to temperatures below freezing. If the unit is installed outdoors, the drain pipe, water trap and discharge pipe should be insulated. The water trap should not be exposed to direct sunlight. Fläkt Woods 8644 GB Specifications are subject to alteration without notice

3 8673 GB damper EQAZ-12, EQAZ-13, STAZ-30, STBZ-30» INSTALLATION INSTRUCTION eqaz-12 damper, staz-30/stbz-30 damper actuator and eqaz-13lever actuator damper actuation The damper can be actuated by means of the STAZ-30/ STBZ-30, damper actuator (accessory) or the EQAZ-13 lever actuator (accessory) as shown. commissioning Damper actuator (accessory) caution! When starting the fan, make sure that the intake damper is open. The maximum permissible pressure differential when the damper is closed is 1000 Pa. Maximum torque loading on the damper: 30 Nm. insulation External dampers are supplied with a cover over the lever actuator system. This permits external insulation of the damper. External damper is always 200 mm wide. Internal damper is 100 mm wide for size eq and for eq mm. You can get damper blades in density class CEN 3 and CEN4 and insulated (Optional). Fläkt Woods 8673 GB Specifications are subject to alteration without notice

4 Installation instruction 2 damper Torque The table below specifies the necessary torque, for density class CEN 3. EQAZ-12-bbb-ccc-3-e-f-gg-2-i-j Number of blade Torque Damper height Damper width Torque Max 8 Nm Max 15 Nm Max 16 Nm Max 24 Nm Over 24 Nm Fläkt Woods 8673 GB Specifications are subject to alteration without notice

5 Installation instruction 3 damper Torque The table below specifies the necessary torque, for density class CEN 4. EQAZ-12-bbb-ccc-4-e-f-gg-2-i-j Number of blade Torque Damper height damper width Torque Max 8 Nm Max 15 Nm Max 16 Nm Max 24 Nm Over 24 Nm Fläkt Woods 8673 GB Specifications are subject to alteration without notice

6 Installation instruction 4 Damper actuator Internal dampers Damper blades 100 mm wide Damper actuator The damper can be controled by means of the EQAZ-13 lever actuator (accessory) or STAZ-30/STBZ-30 damper actuator (accessory). Starting the unit Motor mounting, included in the STAZ-30/ STBZ-30 Important! Make sure that the intake damper is open before the fan is started. The maximum permissible pressure differential across a closed damper is 1000 Pa. STAZ-30/ STBZ-30 Damper actuator Gearwheels Change of damper actuators STAZ-30/STBZ-30, see next page. Extarnal dampers Internal dampers Damper blades 200 mm wide Links Motor mounting, included in the STAZ-30/ STBZ-30 STAZ-30/ STBZ-30 Damper actuator Fläkt Woods 8673 GB Specifications are subject to alteration without notice

7 Monteringsinstruktion Installation instruction 5 Monteringsinstruktion Monteringsinstruktion Monteringsinstruktion Byte av ställdon Byte avställdon ställdon Byte Byte av av ställdon Change of actuators Demontering och montering av ställdon för Demontering och montering av ställdon för invändiga 100 mm spjällof actuators Demontering och montering av Removal and replacement forför Demontering montering avställdon ställdon för invändiga 100och mm spjäll internal 100 mm dampers invändiga 100 mm spjäll invändiga 100 mm spjäll Skär upp eventuell utomhustätning upp- och nertill. Luckstolpe måste demonteras vid ställdons byte. OBS! Återanvänd samma skruvar, annars risk för Luckstolpe demonteras vidreplacement. ställdons byte. Door postmust bemåste removed at the actuator Luckstolpe måste demonteras vid byte. Luckstolpe demonteras vidställdons ställdons byte. luftläckage. OBS! Återanvänd samma skruvar, annars risk för NOTE! Reuse themåste same screws, other wise risk of air leakage. tätningslisten. Skär uppbort eventuell utomhustätning ochthe nertill. CutMontera up eventually outdoor sealing up and down.uppremove sealing. Screws mustsom be removed. screws areen located under a plastic Skruvar måste Some demonteras. del skruvar screw, remove with a screwdriver. Screws are placed on the top, under plastplugg som kan demonteras med en Skruvarensom måste demonteras. En del skruvar Skruvar som måste demonteras. En del Skruvar som måste demonteras. En delskruvar skruvar skruvmejsel. Skruvarna uppoch nertill samt på bottom anden middle. under plastplugg som kan demonteras med en Install the sealing back.tätningslisten. Return with new sealing on top and bottom. Montera tillbaks Skär upp utomhustätning Skär uppeventuell eventuell utomhustätninguppupp-och ochnertill. nertill. Montera bort tätningslisten. Montera bort tätningslisten. Montera bort tätningslisten. OBS! Återanvänd OBS! Återanvändsamma sammaskruvar, skruvar,annars annarsrisk riskför för luftläckage. luftläckage. luftläckage. Återförsegla medtätningslisten. ny tätning upp- och nertill. Montera tillbaks Montera tillbaks tätningslisten. Montera tillbaks tätningslisten. Återförsegla med ny tätning upp- och nertill. Återförsegla Återförseglamed medny nytätning tätninguppupp-och ochnertill. nertill. under en som kan demonteras med en under en plastplugg plastplugg som kan demonteras mitten. skruvmejsel. Skruvarna uppoch nertillmed samt en på skruvmejsel. Skruvarna uppoch nertill skruvmejsel. Skruvarna upp- och nertillsamt samtpå på mitten. mitten. mitten. Fläkt Woods Specifications are subject to alteration without notice 8673 GB Fläkt Woods 9285 SE Rätt till ändringar förbehålls Fläkt Woods 9285 SE Rätt till ändringar förbehålls

8 8641 GB AUTOMATIC PURGING VALVE EQAZ-19» INSTALLATION AND MAINTENANCE INSTRUCTION EQAZ-19 AUTOMATIC PURGING VALVE WITH NIPPLE Min. 12 GENERAL The type EQAZ-19 is an automatic float-controlled airpurging valve incorporating a non-return valve. The valve is designed for use in water circuits at maximum conditions of 115 C and 1,1 MPa (11 bar). The valve is impervious to high water temperature and to water containing an anti-freeze. Each valve is pressure-tested and checked for tightness prior to delivery. PRINCIPLE OF OPERATION The float drops as air accumulates in the housing, allowing the valve to open and discharge the air. Water then fills the housing, lifting the float and closing the valve R3/8" ø 34 R3/8" 14 R3/8" INSTALLATION The valve must be installed vertically with the vent facing upwards. Note that a minimum clearance of 12 mm must be provided above the cap. The non-return valve and purging valve are supplied separately. The non-return valve should be fitted in an the nipple before mounting the purging valve in position. The non-return valve is provided with a gasket, providing a self-sealing joint between it and the housing. OPERATION In service, the valve cap on top of the purging valve should be unscrewed two turns. Purging cannot take place if the cap is screwed down fully. 0 cm Valve cap MAINTENANCE The valve may be cleaned as follows if leakage occurs due to the ingress of dirt: Unscrew the housing from the non-return valve, leaving the latter in position in the nipple. Unscrew to top of the housing from the bottom half and clean the components, for example by blowing with compressed air. Valve housing EQAZ-19 Caution! Bear in mind that the water is hot. Non-return valve EQAZ-19 Nippel Mounting on coil Finned coil Fläkt Woods 8641 GB Specifications are subject to alteration without notice

9 8663 GB CONNECTION ACCESSORIES» INSTALLATION AND MAINTENANCE INSTRUCTIONS EQAZ -12 DAMPER EQAZ-25 FLEXIBLE CONNECTION EQAZ-26 CONNECTION PIECE EQAZ-27 COUNTERFLANGE EQAZ-28 PROTECTIVE SCREEN CONNECTION ACCESSORIES Connection accessories EQAZ-25 flexible connection, EQAZ-26 connection piece and EQAZ-28 protective screen are factory-fitted to the unit section. The EQAZ-27 counterflange is delivered separately and should be fitted as shown in figure. CONNECTION DUCT Protective screen EQAZ-28 Counterflange EQAZ-27-bb-1 Connection piece EQAZ-26-bb-1 Flexible connection EQAZ-25-bb-1 Damper EQAZ-12 PG-JOINT EQAZ-25 Flexible connection FLANGE CONNECTION EQAZ-25 Flexible Gasket connection EQAZ-27 Counterflange EQAZ-26 Connection piece EQAZ-26 Connection piece Gasket EQAZ-27 Counterflange FLANGED DUCT Gasket Flanged duct Gasket N.B. The weight of the air duct system must not load the unit. Fläkt Woods 8663 GB Specifications are subject to alteration without notice

10 8645 GB COWL EQLZ-02, EQBZ-10» INSTALLATION INSTRUCTION EQLZ-02 COWL (C=2, 3) EQBZ-10, E=1 COWL FOR OUTDOOR USE LOCATION OF OUTLET The cowl is not fitted at the factory. Fit the cowl as follows: Fit the cowl top panels centrally over the protective screen and secure itwith self-tapping screws as shown. Secure the cowl side panels to the unit casing and to the top panel by means of self-tapping screws as shown. Self-tapping-screws, (not included in the delivery) Top panel Side panels (one right-hand panel and one left-hand panel) EQLZ-02 (C=2) FAN OULET EQLZ-02 (C=3) If fitted at the fan outlet, place the protective screen centrally across the fan outlet as shown. Protective screen Self-tapping-screws (not included in the delivery) Fläkt Woods 8645 GB Specifications are subject to alteration without notice

11 AIR DISTRIBUTOR 8672 GB » INSTALLATION AND MAINTENANCE INSTRUCTIONS EQLZ-13 AIR DISTRIBUTOR FITTING The EQLZ-13 air distributer is normally supplied fitted but if not (1) fit the support brackets to the top and bottom of the fan outlet. (2) Slide the rods into the folds provided at each end of the fabricand then through each of the end holes (3) at the ends of the support brackets. Secure with the cotter pins provided. Fläkt Woods 8672 GB Specifications are subject to alteration without notice

12 8671 GB PrEssurE measuring EQuiPmEnt» INSTALLATION INSTRUCTION EQPZ-12 (b=1) manometer Version for sizes Measurement range of the manometer: up to 400 Pa. Temperature range C. Use screws to secure the manometer (manometers) to the adjacent panel or to a separatelymounted plate, and connect the hoses supplied as shown to the measurement tappings on the framework. note! When connecting a analog manometer, connect T-coupling and tube as shown in the image. Manometer (manometers) EQPZ-12 (b=1) mounted on panel filter EQPA or filter EQPB. Version for sizes EQ-frame member 2. Inspection door note! Two manometers for installations with pre-filter (EQPB). Fläkt Woods 8671 GB Specifications are subject to alteration without notice

13 .10 INCHES OF WATER MAGNEHELIC CALIBRATED FOR VERTICAL POSITION EQPZ-12 (b=3) Differential manometer EQPZ-25, EQPZ-26 Differential manometer Dichte 1,0 100 Pa = 1 mbar DBGM Pa.10 INCHES OF WATER MAGNEHELIC CALIBRATED FOR VERTICAL POSITION Differential Manometer EQPZ-12 (b=3) Temperature range 20 C + 50 C Connect EQPZ-12 (b=3) differntial manometer with a tube in the same manner as EQPZ-12 (b=1). To ensure correct measurements, it is important that the manometer bemounted horizontally and in right angle. The differential manometer is delivered mounted in a recess in the cover and with the tubes connected. Temperature range 6 C +60 C. EQPZ-12 (b=4) Pressure measuring equipment Note! EQPZ-26 consist of two differential manometers. 0 Pa 1200 Pa EQPZ-12 (b=2) Differential manometer Pa Pa Manometer EUPZ-12 (b=4) Temperature range 15 C + 50 C Temperature range 40 C + 50 C L L 1 N N Pa 220 V, 50 Hz Pa Wirung diagram Fläkt Woods 8671 GB Specifications are subject to alteration without notice

LQLR Fan. Installation instruction. Outlet: Installation. Inlet:

LQLR Fan. Installation instruction. Outlet: Installation. Inlet: Installation : LQLZ-04 Protective screen LQLZ-03 counterflange LQLZ-01 flexible connection LQLZ-02 connection piece Inlet: Fig. 1 LQLZ-09 damper LQLZ-06 connection piece LQLZ-05 flexible connection LQLZ-07

More information

EULR Fan. Fläkt Woods 8192 GB Specifications are subject to alteration without notice

EULR Fan. Fläkt Woods 8192 GB Specifications are subject to alteration without notice Page Installation..................2 Installation alternatives..........2 Connection to the inlet/outlet duct..3 Connection of duct to the fan outlet..3 Electrical connections...........3 Guards.....................4

More information

RoomMaster ABR-2. Installation

RoomMaster ABR-2. Installation Installation List of contents General General... 3 Specification... 3 Accessories... 3 Dimensions and weight... 3 Delivery and transport... 4 Disassembling the unit... 4 Positioning the unit... 5 Reduced

More information

Pressure control damper ERPA

Pressure control damper ERPA Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for

More information

ECONOVENT PUM Installation and maintenance instructions for rotary heat exchangers

ECONOVENT PUM Installation and maintenance instructions for rotary heat exchangers Plant: Heat exchanger designation: ECONOVENT PUM Installation and maintenance instructions for rotary heat exchangers Contents Design, Condition on delivery........................................3 Handling,

More information

EUP(A,B,C) Filters. Replacmeent filters. Size (bb) 11, 20, 21, 22, 30, 31, 32, 33, 40, 41, 42, 44, 50, 51, 52, 53

EUP(A,B,C) Filters. Replacmeent filters. Size (bb) 11, 20, 21, 22, 30, 31, 32, 33, 40, 41, 42, 44, 50, 51, 52, 53 As dust gradually accumulates in the filter, the air flow resistance will increase and this will cause the air flow to decrease. The filter must therefore be changed at regular intervals, the frequency

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

Air Handling Unit Construction Checklist

Air Handling Unit Construction Checklist Air Handling Unit Construction Checklist Project: Date: AHU Tag: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.

More information

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1 26 - COOLING SYSTEM CONTENTS Page LAND ROVER V8 DESCRIPTION AND OPERATION ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 FAULT DIAGNOSIS COOLING SYSTEM FAULTS... 1 REPAIR COOLANT - DRAIN

More information

This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber.

This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber. Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber Chapter 5 Inspection and maintenance This chapter describes how to perform periodic inspection and maintenance to ensure

More information

Section 10 Chapter 17

Section 10 Chapter 17 Section 10 Chapter 17 24 Valve, 8.3 Liter Engine Air Intake System Note: All coding used in the 8.3 Liter and 9 Liter engine manuals are Cummins engine codes. These engine codes have no meaning to New

More information

CENTRIFUGAL FANS INSTALLATION AND MAINTENANCE INSTRUCTIONS EQLR CENTRIFUGAL FAN

CENTRIFUGAL FANS INSTALLATION AND MAINTENANCE INSTRUCTIONS EQLR CENTRIFUGAL FAN CENTRIFUGAL FANS INSTALLATION AND MAINTENANCE INSTRUCTIONS EQLR CENTRIFUGAL FAN Size 008-090 CONTENTS PAGE STORAGE BEFORE INSTALLATION...2 INSTALLATION...3 INSTALLATION ALTERNATIVES...3 CONNECTION TO FAN

More information

Rotary heat exchanger EURA split rotor, sizes 50 53

Rotary heat exchanger EURA split rotor, sizes 50 53 Delivery units Sizes 50 53 are always supplied as two delivery units with a split rotor; see Fig. 2. Measurement nipples 1835 Fig. 1 Fig. 2 Dimensions and weights 3348 ø D Service access space D/2 Lifting

More information

Rotary heat exchanger EURA, 20 53

Rotary heat exchanger EURA, 20 53 Rotary heat exchanger EURA, 0 5 Fig. Adjustment At a constant speed, check that the rotor is rotating in the right direction. The direction of rotation is indicated on the casing. If the purging sector

More information

Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT

Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT 1. General The pressure transducer is designed for use in ventilation systems intended for variable flow by keeping the

More information

Air Handling Units. Geniox. Accessories

Air Handling Units. Geniox. Accessories Air Handling Units Geniox Accessories The right accessories are important to optimise your Geniox air handling unit to the task at hand. SystemairCAD provides you with a wide selection of accessories.

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/ Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16

More information

Butterfly valves, PN6, PN10, PN16

Butterfly valves, PN6, PN10, PN16 4 131 Butterfly valves, PN6, PN10, PN16 VKF41... Butterfly valves for fitting between counter-flanges Nominal pressures PN6, PN10, PN16 Nodular cast iron GG-20 / GG-25 Metallic tight-closing (end-stop)

More information

Recommended Scheduled Maintenance

Recommended Scheduled Maintenance 2004-0-22 (4) Illustrated seat Be-Ge 86-52 incl Rotolift 3 Recommended Scheduled Maintenance Daily Inspection: Inspections every,000 working hours: Inspect and perform, if necessary, the required maintenance

More information

Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT

Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT 1. General The pressure transducer is designed for use in ventilation systems intended for variable flow by keeping the

More information

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance 119 Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden Installation manual Intake system and ventilation Industrial engines DC09, DC13, DC16 OC16 01:02 Issue 10 en-gb Changes from the previous issue...3 Intake air...4 Intake air taken from outside engine room...

More information

Butterfly valves PN6, PN10, PN16

Butterfly valves PN6, PN10, PN16 4 131 ACVATIX Butterfly valves PN6, PN10, PN16 VKF41.. Grey cast iron housing EN-GJL-2 DN 40 200 k vs 4000 m 3 /h For fitting between PN 6, PN 10, PN 16 counter-flanges to ISO 7005 Metallic tight-closing

More information

Regulation and shut-off damper SPB and SPC

Regulation and shut-off damper SPB and SPC SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are

More information

Accessories. Series REC

Accessories. Series REC Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73

More information

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,

More information

Installation manual. SCR system. Marine engines DI13, DI16. 02:07 Issue 1.0 en-gb. Scania CV AB 2016, Sweden

Installation manual. SCR system. Marine engines DI13, DI16. 02:07 Issue 1.0 en-gb. Scania CV AB 2016, Sweden Installation manual SCR system Marine engines DI13, DI16 377 168 02:07 Issue 1.0 en-gb SCR and reductant...3 System overview...4 Exhaust pipe...6 Pipe lengths... 6 Exhaust pipe bends... 7 Pipe material...

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

VE4000 & VE5000 SERIES

VE4000 & VE5000 SERIES VE4000 & VE5000 SERIES CLASS "A" GAS VALVES PRODUCT HANDBOOK APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers,

More information

VEM motors Thurm GmbH

VEM motors Thurm GmbH VEM motors Thurm GmbH Installation, Operating and Maintenance Instructions Single-Phase Squirrel-Cage Induction Motors, Standard Version March 2005 1. General To avoid damage to the motors and equipment

More information

HPP06. Hydraulic Powerpack. HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark

HPP06. Hydraulic Powerpack. HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark Hydraulic Powerpack HPP06 HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark Tel: +45 9647 5200 Fax: +45 9647 5201 Mail: hycon@hycon.dk www.hycon.dk Contents Page 1. Safety Precautions... 2 2. Filling

More information

OPTIVENT Housing HVSA, HVSL

OPTIVENT Housing HVSA, HVSL OPTIVENT Housing HVSA, HVSL Key features Variable air flow Constant air flow Real time air flow display with compact controller 227VM The HVSA and the HVSL are apartment-specific room ventilation regulators

More information

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION Cooling system component layout 26-2-2 DESCRIPTION AND OPERATION 1 Heater matrix 2 Heater return hose 3 Heater inlet hose 4 Heater inlet pipe 5 Throttle housing 6 Connecting hose 7 Throttle housing inlet

More information

CTVK Supply air diffuser

CTVK Supply air diffuser CTVK Supply air diffuser The CTVK is a very quiet supply air diffuser designed for wall mounting. The diffuser is suitable for use in small premises, such as offices, houses and hotel rooms. The air discharged

More information

VIFB Coil Technical Guide

VIFB Coil Technical Guide TGVIFB-5 VIFB Coil Technical Guide VERTICAL TUBE INTEGRAL FACE AND BY-PASS HEATING COILS FOR AIR PREHEATING Since 1875, the L.J. Wing Company has been a leader in providing innovative solutions for difficult

More information

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

VE Series. Class A Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various Class "A" Gas Valves Product handbook APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting furnaces,

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Installation manual. SCR system. Marine engines DI13, DI16. 02:07 Issue 4.0 en-gb. Scania CV AB 2017, Sweden

Installation manual. SCR system. Marine engines DI13, DI16. 02:07 Issue 4.0 en-gb. Scania CV AB 2017, Sweden Installation manual SCR system Marine engines DI13, DI16 390 761 02:07 Issue 4.0 en-gb Changes from the previous issue...3 SCR and reductant...3 32.5% by weight of urea... 4 40% by weight of urea... 4

More information

Installation. Installation. 12. System Diagram... 10

Installation. Installation. 12. System Diagram... 10 Pressure Control Systems Installation Instructions Form No. F-1031 Section 3010 Issue Date 08/20/96 Rev. Date 9/11/17 Table of Contents Discharge Relief Valve System System Description....................................

More information

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel ICP INSTALLATION INSTRUCTIONS manual outside air hood / filter (NPMANDPR004A00) (NPMANDPR005A00) and (NPMANDPR006A00) The package includes the outside air hood, the filter access door and the filter. This

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA AIR COMFORT AIR DIFFUSION CHILLED BEAMS IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA 2 Chilled beam IQ Star NOVA II Technical data CHILLED BEAM IQ STAR NOVA II The NOVA II chilled beam is an active chilled

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

EUL(B,F) FAN. Fläkt Woods 3178 GB Specifications are subject to alteration without notice

EUL(B,F) FAN. Fläkt Woods 3178 GB Specifications are subject to alteration without notice Page Storage before installation.........2 Before starting................2 Maintenance..................2 Cleaning.....................2 Withdrawing the fan from the unit Applicable to size 11 32 EUL(B,F)

More information

Timing Belt: Service and Repair Installation NOTE: Check the water pump for water leakage and the oil seal for oil leakage.

Timing Belt: Service and Repair Installation NOTE: Check the water pump for water leakage and the oil seal for oil leakage. 1991 Daihatsu Truck Rocky L4-1589cc 1.6L SOHC Page 1 Timing Belt: Service and Repair Installation NOTE: Check the water pump for water leakage and the oil seal for oil leakage. Repair any water leakage

More information

ENGINE ASSEMBLY. COMPONENTS (Part 1)

ENGINE ASSEMBLY. COMPONENTS (Part 1) 1 of 32 ENGINE ASSEMBLY COMPONENTS (Part 1) 2 of 32 COMPONENTS (Part 2) 3 of 32 COMPONENTS (Part 3) 4 of 32 COMPONENTS (Part 4) 5 of 32 COMPONENTS (Part 5) 6 of 32 COMPONENTS (Part 6) 7 of 32 COMPONENTS

More information

1992 Toyota Cressida

1992 Toyota Cressida Monday, May 16, 2016 5:32:47 PM Page 13 2005 Mitchell Repair Information Company, LLC. Fig. 7: Exploded View Of Typical Cylinder Head & Components Fig. 8: Cylinder Head Bolt Removal Sequence Monday, May

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

ESAS Smoke control damper

ESAS Smoke control damper ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS

More information

AJV8 Engine Assembly. AJV8 Engine Assembly

AJV8 Engine Assembly. AJV8 Engine Assembly AJV8 Engine Assembly Contents Cylinder Block Dowels, Plugs and Pipes 2 4 Crankshaft Bearing and Cylinder Bore Dimensions 5 9 Bearing Measuring 6 Engine Dimensions and Codes 6 7 Main Bearing Selection Chart

More information

ATP-2040 Electric Damper Actuator/Transmitter

ATP-2040 Electric Damper Actuator/Transmitter ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential

More information

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date: ISP-500B Oil-free Scroll Vacuum Pump Instruction Manual View our inventory Serial Number: Record of Pump Information Purchase date: In Service date: Dealer information: IM-500B 1/3/07 Page 1 of 26 Important

More information

ROOFMASTER STEF ROOF FAN

ROOFMASTER STEF ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF...3 Performance Data...4 Performance Table...6 General description...8 Fan Chart-explanation and

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim Reciprocating pump PMF / GMF This is a multi-line reciprocating pump for many applications - Subject to modifications - Being a universal type, our reciprocating pump is capable of meeting any challenge.

More information

VT Oil-Free Range Operators Handbook

VT Oil-Free Range Operators Handbook VT Oil-Free Range Operators Handbook Covering Models:- VT7 / VT7D VT10 / VT10D VT200 / VT200D VT300 / VT300D VT00 / VT00D BAMBI AIR COMPRESSORS LTD 12 Thimble Mill Lane Heartlands Birmingham B7 HT Tel:

More information

AVK SERIES 55 AND 06 GATE VALVES, DN 450/500/600

AVK SERIES 55 AND 06 GATE VALVES, DN 450/500/600 AVK SERIES 55 AND 06 GATE VALVES, DN 450/500/600 1. Introduction The valve has a full and straight bore corresponding to the nominal diameter and can be installed independently of the flow direction. Although

More information

HIGH FUEL PRESSURE LINE

HIGH FUEL PRESSURE LINE 16 07 HIGH FUEL PRESSURE LINE High Pressure Pump Description This pump generates high fuel pressure and is driven by timing chain (radial plunger principle). This pump pressurizes the fuel to approx. 1600

More information

VXI Closed circuit cooling towers

VXI Closed circuit cooling towers Closed circuit cooling towers Key benefits Reliable Quiet Compact characteristics Counter flow, centrifugal fan, forced draft Capacity range up to 2615 kw Maximum entering fluid temperature 82 C Typical

More information

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

Butterfly valves PN 16

Butterfly valves PN 16 s 4 119 ACVATIX TM Butterfly valves PN 16 VKF42.. Gray cast iron or nodular cast iron valve body DN 50...600 k vs 65...37,000 m 3 /h For fitting with PN 16 counter-flanges to ISO 7005 Tight-closing in

More information

PANCAKE AND HOT DOG AIR COMPRESSORS PARTS LIST

PANCAKE AND HOT DOG AIR COMPRESSORS PARTS LIST PANCAKE AND HOT DOG AIR COMPRESSORS MODEL H330/H331 PARTS LIST COPYRIGHT APRIL, 2003 BY GRIZZLY INDUSTRIAL, INC. WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN

More information

Installation and Operating Instructions

Installation and Operating Instructions Original Installation and Operating Instructions Hawle E2 Valve with Flange Outlet, System 2000 or PE Spigot Ends Table of Contents A) General...... 2 A1 Symbols..... 2 A2 Intended use... 2 A3 Labeling...

More information

Issue 4 (Record Only) Job #: Innovent Submittal Date: October 30, 2012 Project: Location: Columbus, OH Innovent Job #: Submittal Issue: 4 (Record Only) Engineer: Contractor: Tag Innovent Model # AHU-BG-01

More information

Halton Rex 600 RE6 - Adaptable active chilled beam

Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Square Duct Fans - ESTOC TARGE Range Features Sizes from 55 to 6 mm diameter Air flow 21, m /h (5.8 m /s) Static pressures up to 145 Pa Maximum temperature up to 11 C Controllable external rotor motors

More information

Instructions for the BCEA Rotary heat exchanger

Instructions for the BCEA Rotary heat exchanger Instructions for the Rotary heat exchanger 1. General The heat recovery section is a rotary heat exchanger with high temperature and humidification efficiencies. The heat exchanger operates with an efficiency

More information

ECONET Fault and error manual

ECONET Fault and error manual Fault and error manual March 2009 Contents Basic data to get started...3 A Alarms 1. Ice alarm, GT 42...4 2. Frost alarm, GT 41...4 3. Pump alarm, P 40...5 4. Pressure alarm, GP 40...5 5. Liquid, temperature

More information

Kitchen exhaust fan GLEB

Kitchen exhaust fan GLEB Kitchen exhaust fan GLEB Contents General description...3 Quick selection...5 Design description...5 Material and design...6 Fan impeller...6 Motor...6...6 Quality...6 Specification...6 Technical data

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes Instructions for the BASIC BCVA Rotary heat exchanger, Sizes 080 120 1. General The BCVA heat recovery unit is a rotary heat exchanger that offers high temperature efficiency. The heat exchanger operates

More information

Timing Belt: Service and Repair

Timing Belt: Service and Repair Timing Belt: Service and Repair REPLACING TIMING BELT/IDLER PULLEY/BELT TENSIONER B 52X4 S Removing timing belt Remove components Caution! Note! Remove the ignition key from the ignition switch before

More information

MOTOR DRIVE UNIT MA General Technical Data Design Control Circuit Assembly... 7

MOTOR DRIVE UNIT MA General Technical Data Design Control Circuit Assembly... 7 MOTOR DRIVE UNIT MA 2 Contents Page 1. General... 3 2. Technical Data... 3 3. Design... 4 4. Control Circuit... 7 5. Assembly... 7 6. Putting in to operation... 9 7. Maintenance... 9 8. Special Designs...

More information

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls SPRING CHECK LIST ABSORPTION CHILLERS Check starter and control panel. Leak test. Check hand valve diaphragms and replace as required. Check operation of purge unit. Change oil in the purge pump. Lubricate

More information

Air Handling Units RM-/RL-Line. AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements

Air Handling Units RM-/RL-Line. AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements Air Handling Units RM-/RL-Line AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements robatherm 11/2013 Characteristics of the robatherm casing construction

More information

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation Halton CCE Adaptable active chilled beam for exposed installation Combined cooling, heating, and supply air unit for exposed installation Ideal solution for applications where good indoor environment,

More information

GAS SPRINGS SERVICE INSTRUCTION 8.1/1. Instructions for the service and the maintenance of

GAS SPRINGS SERVICE INSTRUCTION 8.1/1. Instructions for the service and the maintenance of SERVICE INSTRUCTION 8.1/1 Instructions for the service and the maintenance of GAS SPRINGS Contents Page 1. Safety Regulations... 8.1/2 2. Accessories and spare parts... 8.1/3 3. What You should know about

More information

Volkswagen New Beetle 1.8 Liter 4-Cyl. 5V Turbo OBD II Engine Mechanical 19 Engine-Cooling system (Page GR-19)

Volkswagen New Beetle 1.8 Liter 4-Cyl. 5V Turbo OBD II Engine Mechanical 19 Engine-Cooling system (Page GR-19) 19 Engine-Cooling system (Page GR-19) Cooling system components, removing and installing Continued coolant circulation pump (V51), checking Coolant hose connection diagram Coolant pump, removing and installing

More information

NH 3. Evaporator. Ammonia Applications Tons MANP

NH 3. Evaporator. Ammonia Applications Tons MANP NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With

More information

IFOA Integral Flow Orifice Assembly

IFOA Integral Flow Orifice Assembly Instruction MI 022-333 July 2007 Introduction IFOA Integral Flow Orifice Assembly The IFOA integral flow orifice assembly is used in conjunction with a Foxboro electronic or pneumatic differential pressure

More information

TIMING CHAIN COMPONENTS

TIMING CHAIN COMPONENTS h Page 1 of 52 TIMING CHAIN COMPONENTS ht Page 2 of 52 Fig. 24: Displaying Timing Chain Components (1 Of 2) Page 3 of 52 Fig. 25: Displaying Timing Chain Components (2 Of 2) Page 4 of 52 REMOVAL NOTE:

More information

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724)

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724) 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA 15108 PHONE (724) 695-3440 FAX (724) 695-8635 INSTALLATION, OPERATION AND MAINTENANCE FOR (50mm-350mm) 2 THRU 14, EXCEL SERIES 40 WAFER STYLE

More information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710. Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable

More information

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper ETPR. Specifications. Product code example Fire damper ETPR Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.

More information

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25 TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25 (505)872-0037 The TRIVAC NT is the latest generation of well-proven rotary vane pumps. The performance and handling characteristics of

More information

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance

More information

LK Manifold RF. Design. Requirements

LK Manifold RF. Design. Requirements LK Manifold RF Design LK Manifold RF is made of stainless steel, the variants having 1 to 12 floor heating circuits. The manifold is delivered pre-mounted in brackets. The manifold has thermometers on

More information

PUM(O,R,V) AND PUML INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROTARY HEAT EXCHANGERS ROTOR SIZE (460/500)

PUM(O,R,V) AND PUML INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROTARY HEAT EXCHANGERS ROTOR SIZE (460/500) PUM(O,R,V) AND PUML INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROTARY HEAT EXCHANGERS ROTOR SIZE 060 420 (460/500) 2 Installation and maintenance Content Page 1. Description - Unit design... 3 2. Handling

More information

GB2 35/50 GPM Grease Interceptor for Indoor Use

GB2 35/50 GPM Grease Interceptor for Indoor Use INSTALLATION GUIDE GB2 35/50 GPM Grease for Indoor Use Contents Special Precautions.........................................2 Getting to Know the GB2....................................3 On the Floor Installation..................................

More information

Roth NP Manifold System Installation Instructions

Roth NP Manifold System Installation Instructions Roth Industries, Inc. 268 Bellew Avenue South Watertown, NY 360 Ph. 35-755-0 Fax 35-475-0200 www.roth-usa.com info@roth-usa.com ) Product description Constructed of heavy wall extruded nickel plated brass

More information

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM.  QAD#IM6055.REVA LSSN Butterfly Valve Installation Operation Maintenance Licence Number: 5326 www.challengervalves.com.au 1 Index 1. INTRODUCTION 1.1 Design Features 3 1.2 Flange and Pipe Compatibility 4 1.3 Operating

More information

PIERBURG. Carburetor: 2E3

PIERBURG. Carburetor: 2E3 PIERBURG Carburetor: 2E3 1 fast idle adjusting screw 2 throttle lever 3 fuel mixture adjusting screw 4 main body 5 idle cut off valve 6 stop screw 7 accelerator pump cover 8 diaphragm 9 spring 10 valve

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

SECTION 1D1 M162 ENGINE COOLING

SECTION 1D1 M162 ENGINE COOLING SECTION 1D1 M162 ENGINE COOLING CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit or when a tool or equipment could easily come in contact with exposed electrical

More information

DB4604 GMR-SD and GMR40-SD Disc Brake Caliper - Spring Applied, Air Released

DB4604 GMR-SD and GMR40-SD Disc Brake Caliper - Spring Applied, Air Released DB464 GMR-SD and GMR4-SD Disc Brake Caliper - Spring Applied, Air Released Nominal dimensions given. For specific dimensions please contact Twiflex Limited. For GMR Mk 2 caliper details see DB 364 Air

More information

CUSTOM COMBINATION AIR VALVE

CUSTOM COMBINATION AIR VALVE INSTALLATION / OPERATION / MAINTENANCE CUSTOM COMBINATION AIR VALVE INTRODUCTION This manual will provide you with the information to properly install and maintain this valve to ensure a long service life.

More information

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water. 16 Apr 2009 Doc. 1:141J TECHNICAL DATA 5327002 EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED Fresh water connection Shut-off valve Strainer Vacuum breaker 390 Gasket Seat and cover Pneumatic push

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53 Installation, use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 374957 G5BF 49T57 3748953 G5BF 489T53 9036 (6) TECHNICAL FEATURES TYPE - Boiler

More information

Installation instructions, accessories - Fuel driven heater 912-D

Installation instructions, accessories - Fuel driven heater 912-D XC90 Section Group Weight(Kg/Pounds) Year Month 8 87 2002 10 XC90 2003 D5244T, XC90 2004 D5244T, XC90 2005 D5244T AW50/51 AWD, XC90 2006 D5244T, XC90 2006 D5244T AW50/51 AWD D5244T R8703687 Page 1 of 20

More information