Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Size: px
Start display at page:

Download "Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E"

Transcription

1 Replacement Parts List No Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS Vintage E To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 4 Nomenclature Model Number- Dataplate... 5 Serial Number... 5 Model Number- Complete Electrical Legend Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood- No Return Air Plenum % Outside Air Section w/ ACT3... 5, % Economizer Section with Barometric Exhaust Damper % Economizer Section with Prop Exhaust Fan & Damper % Economizer Damper w/ ACT3... 9, 0 California Title 4 Assembly... Prop Exhaust Fan & Damper Detail... Prop Exhaust Fan Control Box... 3 Design Flow (Code 0= JE)... 4 Section Mounted Controls: OAE, RAE, RAT, SD... 5 Section B- Draw-Thru Filter Section Section Mounted Controls- PC Filters... 6 Section D- Draw-Thru Cooling Section Evaporator Coils, Drain Pans, Gasketing... 7 Section E- Draw-Thru Heat Section Hot Water Coil Heat, Mixing Valves and Actuator- VM... 8 Section F- Supply Air Section Air Foil Fan- Double Width (Code 3= 30A*)... 9 Air Foil Fan- Single Width (Code 3= 40B*) Fan Mounts- 30 Airfoil Double Width Fan... 3 Fan Mounts- 40 Airfoil Single Width Fan... 3 Supply Air Fan Motors Inverters... 34, 35 Line Reactors Section Mounted Controls: PC7, HL, EFT, OAT, DAT Section G- Blow-Thru Heat Section Electric Heat Heaters, Diffusers, Hi Limit Cutouts HL- 0, , 39 Electric Heat Control Box (0/3 & Earlier) Electric Heat Control Box (03/3 & Later) Gas Heat- Vestibules, Heat Exchangers and Primary Components Gas Heat- Modulating Burner... 5, 5 Gas Heat- Burner Controls Gas Train- Inlet Gas Train- Controls: GV, GV Gas Train- Outlet Gas Heat- Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting Section K- Discharge Plenum Section Section Mounted Controls: OAT, DAT AND Access Door Latching Assemblies, Key, Lock (ALL sections) Section M- Condenser Section Condenser Fan Deck Assembly- 06E, 06E... 57, 58 Condenser Fan Deck Assembly- 070E, 075E... 59, 60 Compressors & Compressor Components- Unit Size 06E, 06E... 6 Compressors & Compressor Components- Unit Sizes 070E, 075E... 6 Pressure Controls Box- 06E, 06E: AFD, AFD, LR, LR, LP, LP, HP, HP... 63, 64 Pressure Controls Box- 070E, 075E: AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC , 66 Factory Supplied Line Voltage Box: Code 3= YY*FY: T6, DS6, FU6A, FU6B, FU6C Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page

3 Contents, Continued Section N- Main Control Box (0/3 & Earlier) Control Panel- MicroTech III- Diagram Control Box Component Label Diagram Control Panel- MicroTech III- Components... 70, 7 Power Panel- Diagram... 7 Power Panel- Components Terminal Blocks, T Transformer & Fusing, Fuses, Plugs Fusing, Phase Protection, Power Blocks Receptacle, Disconnect Switch Supply MMP0 & M0 Fan Contactor Compressor MMP- 4 and Contactor M- 4-06E... 8 Compressor MMP- 6 and Contactor M E... 8 Compressor MMP- 6 and Contactor M E Condenser Fan MMP,, 3,,, 3 & Contactors M- 4: Fantrol Units (Code 47= ) Condenser Fan MMP- 4, Contactors M- 4, Fuses F, F: Speedtrol Units (Code 47= ) Section N- Main Control Box (03/3 & Later) Control Panel- MicroTech III- Diagram Control Box Component Label Diagram Control Panel- MicroTech III- Components... 88, 89 Power Panel- Diagrams Power Panel- Components Terminal Blocks, T Transformer & Fusing, Fuses, Plugs... 9 Fusing, Phase Protection, Power Blocks... 9 Receptacle, Disconnect Switch Supply MMP0 & M0 Fan Contactor Detail Diagrams Supply Fan Components Compressor MMP- 4 and Contactor M- 4-06E, 06E... 0 Compressor MMP- 6 and Contactor M E Compressor MMP- 6 and Contactor M E Condenser Fan MMP,, 3,,, 3 and Contactors M- 4: Fantrol Units (Code 47= ) Condenser Fan MMP- 4, Contactors M- 4, Fuses F, F: Speedtrol Units (Code 47= ) Intelligent Equipment Section O- Refrigeration Tubing Diagram & Components Hot Gas Reheat (Code 54= BM) Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 3

4 Parts List Revision History Rev. Date Description New /09 New A- R 05/7 Archived Revs. A- R. S 05/7 Page 6-8: Misc. Nomenclature updates/corrections. Page 5: Rewrote footnote #. Page 34: Rewrote footnote #. Page 56: Updated/corrected Door Latching component table & rewrote footnote #. Page 58, 60: Updated Cond. Mtr. Ref #. Rewrote footnotes and footnote notation. T /7 Various: Rewrote/corrected pg. headers. Page 5: Misc. updates. Page 6-8: Misc. Nomenclature updates/corrections. Page 5, 5: Rewrote pg. header. Page 88: Added /7 & Later PVM. Moved transf. to pg. 89. Added footnote # 3. Page 89: Added transf. p/ns from pg. 88. Page 08: Rewrote the pg. header & updated the TOC. Page 09: Added pg. for HGRH info. Repaginated the form & updated the TOC. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 4

5 Nomenclature Model Number- Dataplate Nomenclature Model Number MPS 06 E Light Commercial Packaged Rooftop Nominal Capacity (tons) 06, 06, 070, 075 Design Vintage Nomenclature Serial Number FBO U Plant Identification FBO = Faribault U= Unit Year of Manufacture 09= 009 0= 00 = 0 = 0 etc. Serial Number (Build Sequence) Month of Manufacture 0= January 0= February 03= March 04= April 05= May 06= June 07= July 08= August 09= September 0= October = November = December Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 5

6 Nomenclature Unit Model Number- Complete MPS 06E S A Y EU D 7 AL P LE 3 6 Y CY YYYY YY HE YYYY YYY YYYFY Code Y FD Y CYYP 4Z05D YYYYYY YYYYYY 30A QJY YYYYY 040SEC YYYY YYYYYY YYYYYY Y Y BY Y 4 MS R Y Y Y YYYYYYYYYYYYYYYYY MP YYYYY 50A YY AAA 047C Y Y 0 YYYYYYYY Code 0= Unit Type MPS= Commercial Packaged Rooftop Code 0= Unit Size / Vintage Nominal Tonnage= 06E, 06E, 070E, 075E Code 03= Cooling Coil S= Small L= Large Code 04= Heat Type Y= None A= Natural Gas E= Electric W= Hot Water S= Steam Code 05= Unit Split Y= None F= Split at Fan/Heat Sections Code 06= Insulation and Liners = ½, ½# with solid liners on doors & ceilings 4= ½, ½# with solid liners on Doors, Ceilings and Floors Code 07= Approval Agency Listing YY= None EU, EY= ETL/MEA- USA Code 08= Main Control Box Location D= Discharge Plenum F= Supply Fan Section Code 09= Unit Voltage = 08/60/3 9= 30/60/3 7= 460/60/3 37= 575/60/3 Code 0= Starting Option AL= Across- The- Line Code = Field Power Connection and Disconnect P= Single Power Block: Complete Unit A= One, thru-the-door Disconnect: Complete Unit Code = Temperature Controls MicroTech III Controls Digit : Communication Type L= LonWorks B= BACNet w/mstp E= BACNet w/ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit : Control Type E= Discharge Air w/ Static Pressure Control F= Space OR Zone Ctl. W= Discharge Air w/ Space Control Code 3= Air Flow Controls Y= None = Duct Sensor = Duct Sensors 3= Duct and Space Sensor 4= Space Sensor 5= Duct Hi Limit (DHL) Sensor Code 4= Inverters Y= None 6= SA Fan only no bypass 9= RA Fan only no Bypass Code 5= Inverter Type Y= None S, B= Daikin Applied MD- MD6 Code 6= Smoke Detectors Y= None = Return Air Fan Section Code 7= Misc. Aux. Controls YY= None CP= Differential Enthalpy w/ Phase Failure CY= Differential Enthalpy YP= Mechanical Enthalpy w/ Phase Failure Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 6

7 Nomenclature Unit Model Number- Complete, Continued Code 8= Misc. Controls/ Unit Length Y _= None + actual air handler length Code 9= Return Air Plenum YY= None (no return air section) BY= Bottom Return HY= Back Return Code 0= Outdoor Air Options AE= 0-00% Outside Air Damper w/ Hood & Act. BE= 0-30% Outdoor air section w/ Actuator DE= 0-00% Econ. w/ Barometric Exhaust Damper w/ Act. HE= 0-00% Econ. w/ Prop Exhaust Damper w/ Act. JE= same as HE + Design Flow Code = Return Air Fan YYYY= No Return Air Fan Code = Exhaust Fan Motor YYY= No Exhaust Fan J J Y Always Y J= Premium Eff. ODP J= 5.0 HP Code 3= Misc. Electrical Options Digit, : None YY= None Digit 3: Inverter Brand Y= None B= Daikin Applied Digit 4: 5V Service Outlet Y= None F= Factory Supplied Line Voltage & Receptacle Digit 5: IE Y= None A= Intelligent Equipment (IE) Code 4= Exhaust Fans Y= None = Prop Exhaust Fan w/ Hood = Prop Exhaust Fans w/ Hood Code 5= Draw-Thru Filter Section AB= Angular/30% Throwaway FY= Flat w/ no filter media FE= Flat/95% Cartridge SD= Staggered/65% Cartridge SE= Staggered/95% Cartridge Code 6= Blank Draw-thru Section Y= None Code 7= Draw-Thru Drain Pan/Cooling Coil Section CYYP, CYYY= Cooling coil section w/painted galvanized steel sloped Drain Pan CYYS= Cooling coil section w/stainless steel sloped Drain Pan Code 8= Draw-Thru Cooling Coil YYYYYY= No Cooling Coil 4Z 0 5 D D= Lanced Aluminum 5= 5 Row 6= 6 Row 0= 0 Fins-per-inch = Fins-per-inch 4Z= Type 4EZ Code 9= Draw-Thru Heating Coil YYYYYY= No Heating Coil Code 30= Draw-Thru Heating Section YYYYYY= No Heating Section Hydronic Heat W J 3 E E= Electric Actuator Y= Less Actuator 3= 3 Way HW Valve E= ¼ Valve Pkg. G= Valve Pkg. J= 3.0 Valve Pkg. F= ½ Valve Pkg. H= ½ Valve Pkg. W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5WS HW Coil) Code 3= Supply Air Fan 30A()= 30 Airfoil Double Width, w/o vanes 40B()= 40 Airfoil Single Width, w/o vanes ()= Fan Isolators: = RIS; 3= Spring w/ Seismic Snubbers Code 3= Supply Air Fan Motor K J Y Always Y J= Premium Eff. ODP Motor H= 3.0 HP M= 5.0 HP R= 40.0 HP J= 5.0 HP N= 0.0 HP S= 50.0 HP K= 7.5 HP P= 5.0 HP L= 0.0 HP Q= 30.0 HP Code 33= Miscellaneous Electrical YYYYY= None YFYYY= California Title 4 Economizer w/ Fault Detection/Diagnosis (FDD) YYGYY= Ebtron Gold YYYYE= Electrofin Coated Cooling Coil Code 34= Blow Thru Heat Section YYYYYY= No section, cooling only Gas Heat Breakdown: 00 S E C A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position E= Modulating Burner/Maximum gas pressure= 0.5 psi S= Stainless Steel Heat Exchanger MBH (in 0 s) ex. 040= 00 MBH [040,064,079] Electric Heat Breakdown: E00 Y Always Y = Stage = Stages 4= 4 Stages 6= 6 Stages E00= 0 KW Heater E00= 00 KW Heater E040= 40 KW Heater E0= 0 KW Heater E060= 60 KW Heater E60= 60 KW Heater E080= 80 KW Heater E00= 00 KW Heater Code 35= Blow- Thru Drain Pan YYYY= None Code 36= Blow-Thru Cooling Coil YYYYYY= No Cooling Coil Code 36= Blow-Thru Heating Coil YYYYYY= No Heating Coil Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 7

8 Nomenclature Unit Model Number- Complete, Continued Code 37= N/A to MPS YYYYYY= None Code 38= Attenuator Section Y= None- No Section Code 39= Final Filter Section Y= None Code 40= Discharge Plenum BY= Bottom Discharge LY= LH Side Discharge Code 4= Blank Compartment Section- Out of Airstream Y= None- No Section Code 4= Compressor Capacity Control 4= 4 steps 6= 6 steps Code 43= Condenser Options Digit : Air Coil Y= None M= 5mm Micro Channel Coil P= 5mm Coated Micro Channel Coil T= 3mm Micro Channel Coil U= 3mm Coated Micro Channel Coil Digit : Condenser Options Y= None G= Coil Guards, Steel S= Seal Tite Conduits B= G + S Code 44= Compressor Type R= Scroll R40a Code 45= Compressor Isolation = Resilient Rubber-in-Shear Code 46= Piping Options Y= None = Hot Gas Bypass, Circuit # only Code 57= MPS IM MP= MPS IM Bulletin included Code 58= Return Air Fan Drive Selection YYYYY= None Code 59= Supply Air Fan Drive Selection 50 A A= Standard Service Factor/Fixed Drive Fan RPM Code 60= Miscellaneous YY= None Code 6= Packaging = Steel Skid Codes 6-64= Warranty Code 65= Always 047C Code 66= Drain Connection Location R= RH/ Drive Side L= LH/Opp. Drive Side Y= None Code 67= ASHRAE Certification Y= None B= AHRI Certified C= AHRI Certified D= AHRI Certified Code 68= Short Circuit Current Rating YY= None 0= 0 SCCR = SCCR 65= 65 SCCR Code 69-7 N/A to MPS Always YYYYYYYY Code 47= Low Ambient Operation = Fantrol Standard Fans = Speedtrol Standard Fans Code 48= IBC Seismic Constr/Power Factor Capacitors Y= None Code 49= Fan Section Options Y= None Code 50= Blender Section Y= None Codes Always Y s () Code 54= Hot Gas/Liquid Subcool Reheat YY= None BM= Blow-Thru Modulating (includes SpeedTrol) Codes Always Y s (9) Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 8

9 Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Dampers Economizer Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT 0, Actuator Motors, Exhaust Dampers Return Air Section AFD0 Inverter, Supply Fan AFD or Supply Fan Sect. AFD/VFD Inverter, Speedtrol Motor Condenser Section AFD0 Inverter, Exhaust Fan AFD or Supply Fan Sect. AFD/VFD Inverter, Speedtrol Motor Condenser Section AS Blower Air Switch Furnace Section BM Burner Blower Motor Furnace Section CB0 Circuit Breaker, Supply Fan ( only) Main Control Box COMPR- 6 Compressors Condenser Section DAT Discharge Air Temperature Sensor Discharge section DHL Duct High Limit Main Control Box DS Disconnect, Total Unit or Condenser/Heat Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS6 Disconnect- Unit Supplied Line Voltage Condenser Section EFT Entering Air Temperature Sensor Supply Fan Section EXPA, B Expansion Boards Main Expansion Board F, A Fuses, Control Circuit, T Primary Main Control Box FC Fuse, Control Circuit, T Secondary Main Control Box F Fuse, Control Circuit Condenser Control Box F3 Fuse, Burner Motor Main Control Box F4 Fuse, T4 Transformer Main Control Box F6A, B, C Fuses, Unit Supplied Line Voltage Condenser Section F0 Fuse, Supply Fan ( only) Main Control Box F Fuse, Speedtrol Motor Main Control Box F0 Fuse, Return/Exhaust Fan Main Control Box F Fuse, 08V Speedtrol Motor Main Control Box FB8 Fuseblock, Main Transformer Main Control Box FB3-40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Section FB4-50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Section FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FS Freezestat Coil Section, Heat/Cool FSG Flame Safeguard Furnace Section GRD Ground All Control Boxes GV Gas Valve, Pilot Furnace Section GV, 3 Gas Valves, Main Furnace Section HL- 0 High Limits, Elec. Heaters (Top Bank) Electric Heat Section HL- 0 High Limits, Elec. Heaters (Bottom Bank) Electric Heat Section HL High Limit, Gas Heat (Prefilters) Supply Air Section HL3-40 High Limits, Elec. Heaters (Top Bank) Electric Heat Section HL4-50 High Limits, Elec. Heaters (Bottom Bank) Electric Heat Section HP, High Pressure Controls Condenser Manifold HP5 High Pressure Control, Gas Furnace Section HS Heat Switch, Electric, Shutdown Main Control Box HTR- 6 Crankcase Heaters On Compressors IT Ignition Transformer Furnace Section LP, Low Pressure Controls, Refrigerant Condenser Manifold LP5 Low Pressure Control, Gas Furnace Section LR0 Line Reactor- Exhaust Fan Main Control Box M- 6 Contactors, Compressors Main Control Box Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 9

10 Electrical Legend Continued Schematic Sym. Description Location M0 Contactor, Supply Fan Main Control Box M- 5 Contactors, Condenser Fans, Circuit # Main Control Box M- 5 Contactors, Condenser Fans, Circuit # Main Control Box M9 Contactor, Burner Motor Furnace Section M30 Contactor, Supply Fan Inverter Inverter Bypass Box M3-39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M4-50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M5, 5, 53 Contactors, Prop Exhaust Fan Motor Return Air Section MCB Microprocessor Control Board Main Control Box MJ Mechanical Jumpers Terminal Blocks MMP- 6 Manual Motor Protectors, Compressors Main Control Box MMP0 Manual Motor Protector, Supply Fan Main Control Box MMP- 4 Manual Motor Protectors, Cond. Fans Ckt. Main Control Box MMP5, 5 Manual Motor Protectors, Prop Exhaust Return Air Section MP- 6 Motor Protectors, Compressors On Compressors NB, Neutral Blocks Main Control Box OAE Outside Air Enthalpy Control Economizer Section OAT Outside Air Temperature Sensor Discharge Bulkhead OL0 Overload Relays, Supply Fan Main Control Box OL5, 5 Overload Relays, Prop Exhaust Fan Return Air Section PB Powerblock, Main Main Control Box PB3 Powerblock, Electric Heat Electric Heat Section PC5 Pressure Control, Clogged Filter Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Filter PC8 Pressure Control, Minimum Airflow Evaporator Coil Section PVM Phase Voltage Monitor Main/Cond. Control Box R, Relays, High Pressure Reset Main/Cond. Control Box R Relays, Compressor, Safety/Cool Fail Main/Cond. Control Box R9, 0 Relays, Compressor Lockout Main/Cond. Control Box R Relay, Speedtrol Inverter Main/Cond. Control Box R3., 4. Relays, Compressor, Safety/Cool Fail Main/Cond. Control Box R, 3, 4 Relays, Condenser Fans Main/Cond. Control Box R8, 9 Relays, Cool Failure Indicator Main Control Box R0 Relay, HW or Electric Heat Main Control Box R0,, Relays, Gas Heat Furnace Section R3 Relay, Gas Heat Valve or Electric Heat Furnace or Elec. Ht. CB R4 Relay, Gas Heat Alarm Main Control Box R5 Relay, Gas Heat Start, Supply Fan Inverter Main Control Box R6 Relay, Occupied/Unoccupied Main Control Box R7 Relay, Exhaust Dampers Main Control Box R30 Relay, Cool Valve w/ F&B Main Control Box R46, 47 Relays, Supply Fan Inverter increase/decrease Main Control Box R6 Relay, Special Main Control Box R67 Relay, Supply Fan Enable Main Control Box R69 Relay, Inverter Bypass VAV Box Interlock Main Control Box R8, 8 Relays, Inverter Reset Main Control Box R83-88 Relays, Smoke Main Control Box RAE Return Air Enthalpy Sensor Return Air Section RAT Return Air Temperature Sensor Return Air Section REC Receptacle, Main Box Main Control Box R4 Relay, Gas Heat Alarm Main Control Box R5 Relay, Gas Heat Start, Supply Fan Inverter Main Control Box Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 0

11 Electrical Legend Continued Schematic Sym. Description Location R6 Relay, Occupied/Unoccupied Main Control Box R7 Relay, Exhaust Dampers Main Control Box R30 Relay, Cool Valve w/ F&B Main Control Box R46, 47 Relays, Supply Fan Inverter increase/decrease Main Control Box R6 Relay, Special Main Control Box R67 Relay, Supply Fan Enable Main Control Box R69 Relay, Inverter Bypass VAV Box Interlock Main Control Box R8, 8 Relays, Inverter Reset Main Control Box R83-88 Relays, Smoke Main Control Box RAE Return Air Enthalpy Sensor Return Air Section RAT Return Air Temperature Sensor Return Air Section REC Receptacle, Main Box Main Control Box REC3 Receptacle, Field Power, 5V Discharge Bulkhead S Switch, System On/Off Main Control Box S3 Switch, Furnace On/Off Furnace Section S4 Switch, Inverter Bypass On/Off Main Control Box S7 Switch, Local On/Off/Auto to Controller Main Control Box SD Smoke Detector, Return Air Return Air Section SPS,, 3 Static Pressure Sensors, Duct or Building Main Control Box SPTRL Switch- Speedtrol Pressure Condenser Section SR- 3 Sequence Relays, Electric Heat Electric Heat Section SV- 4 Solenoid Valves, Liquid Discharge Bulkhead SV5-8 Solenoid Valves, Hot Gas Discharge Bulkhead T Transformer, Main Control Main Control Box T Transformer, Unit 4V Main Control Box T3 Transformer, Controller, 8V Main Control Box T4 Transformer, Exhaust Dampers Main Control Box T5 Transformer, Electric Heat Electric Heat Section T6 Transformer, Unit Supplied 0V Power Condenser Section T7 Transformer, Gas Pilot Valve Furnace Section T8 Transformer, Gas Main Valve Furnace Section TB Terminal Block, 5V, Field Main Control Box TB Terminal Block, 4V, Field Main Control Box TB5 Terminal Block, 5V, Factory Main Control Box TB6 Terminal Block, 5V/4V, Factory Main Control Box TB7, 8 Terminal Blocks, 4V, Factory Main Control Box TB0 Terminal Block, Heating Main Control Box TB Terminal Block, Heating Electric Heat Section TB, 3 Terminal Blocks, Electric Heat, Power Electric Heat Section TD0 Time Delay, Duct Hi Limit Main Control Box TR, Transducers, Pressure Main Control Box VM Valve Motor, Heating Heating Section VM5 Valve Motor, Cooling Coil Section, Cool VV Vent Valve Furnace Section ZNT Zone Temperature Sensor, Control Field Installed Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page

12 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood Code 0= AE AND Code 9= YY No Return Air Plenum 9 00 Air Flow Section B Ref. Part Part Qty. No. Description Number N/S Damper Assy- Complete 00 Damper Only Liner Panel- Hood Side Panel- Hood Side Panel- Hood Top Louver Channel- Support Channel- Support N/S= Not shown on diagram. This Damper Assy. includes the Damper, Damper Linkage, and Actuator. For Damper Assy. components see the following two pages. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page

13 Section A- Outdoor/Return Air Section 00% Outside Air Damper Detail w/act3 Code 0= AE AND Code 9= YY Diagrams Motorized Linkage Detail Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 3

14 Section A- Outdoor/Return Air Section 00% Outside Air Damper Detail w/act3 Code 0= AE AND Code 9= YY Components Ref. Part Part Qty. No. Description Number 4 Shaft- Linkage Adapter Plate- Crank Arm Blade- Damper Grille Stop-Anti Rotate, Damper Support- Damper Motor Linkage Bar Drive Tab Crank Arm- Damper Ball Joint- Damper Actuator- Motorized, 4V ACT Bushing- Linkage Bar, Nylon Bushing- Damper Blade, Nylon Gasket- Vinyl Gasket- Vinyl Plug- Damper End Plug- Damper End Plug- Damper End Bearing- Flange Sleeve Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 4

15 Section A- Outdoor/Return Air Section 0-30% Outside Air Section w/ ACT3 Code 0= BE Diagrams Linkage Detail: 5/ & Earlier Linkage Detail: 6/ & Later Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 5

16 Section A- Outdoor/Return Air Section 0-30% Outside Air Section w/ ACT3 Code 0= BE Components Ref. Part Part Qty. No. Description Number N/S Damper Assembly- Complete Damper Only Blade- Damper Gasket- Vinyl Gasket- Vinyl Seal- End Grille Support- Motor 5/ & Earlier Support- Motor 6/ & Later Bar- Linkage Shaft- Linkage Louver Plug- End Plug- End Bushing- Damper Blade Bushing- Linkage Bar, Nylon Ball Joint- Damper Actuator- Motorized, 4V ACT Crank Arm- Damper Bushing- Actuator Channel Retainer 5/ & Earlier Channel Retainer 6/ & Later N/S= Not Shown on Diagram. Damper assy includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Damper only, NO Actuator Linkage OR Actuator. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 6

17 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Barometric Exhaust Damper Code 0= DE Back Return (Code 9= HY) shown. Air Flow Ref. Part Part Qty. No. Description Number N/S Damper Assembly- Complete Damper Only Exhaust Damper Assy.- Barometric N/S= Not Shown on diagram. Economizer Damper detail one page after next. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Damper only, NO Actuator Linkage OR Actuator. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 7

18 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Prop Exhaust Fan & Damper Code 0= HE AND Code 4=, Section Assembly Detail fan arrangement shown (Code 4= ) 0 40 Fan Guard Ref. Part Part Qty. No. Description Number 40 Fan Assembly 08/30/ Fan Assembly Fan Guard Panel- Weather Hood Hood- Prop Exhaust N/S Grille Only- Prop Exhaust Hood 80 3 N/S= Not Shown on diagram. See detail following Isolation Damper Detail. Quantity may be one (Code 4= ) OR two (Code 4= ). 3 Quantity is PER fan. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 8

19 Section A- Outdoor/Return Air Section 0-00% Economizer Damper Detail Code 0= DE, HE, JE Diagrams Linkage Detail: With Actuator (Code 0= *E) Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 9

20 Section A- Outdoor/Return Air Section 0-00% Economizer Damper w/ ACT3 Code 0= DE, HE, JE Components Ref. Part Part Qty. No. Description Number Damper Assy- Complete Damper Only Shaft Assembly Plate- Crank Arm Shaft- Linkage Channel- Support Blade- Damper Stop/Anti-Rotate- Damper Bar- Linkage Drive Tab- Linkage Bar Ball Joint- Damper Actuator- 4V ACT Bushing- Linkage Bar Bushing- Damper Blade Gasket- Vinyl Gasket- Vinyl End Plug- Damper End Plug- Damper End Plug- Damper Bushing- Actuator Channel- Actuator N/S Gasket- Neoprene N/S= Not Shown on Diagram. Includes the Damper Assy, Actuator Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Damper only, NO Actuator Linkage OR Actuator. 3 Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 0

21 Section A- Outdoor/Return Air Section California Title 4 Assembly Code 33= *F*** Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch Bracket, Mounting Switch Switch, Push Button SPDT Bushing, Conduit 3630 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page

22 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Detail Code 0= HE, JE AND Code 4=, 40A 40 Fan Assembly Components - Fan Arrangement Shown- Code 4= 54 5 B A 6C 6B 6D 6E 6F 6G 6H Lube Line Detail 53 Control Box (see following page) 6I Voltage Ref. Sch. Part Part No. Sym. Description Number AFD0 Inverter see charts on following pages A Resistor- Inverter B Jumper- Inverter B Fan Prop C Fan Shaft D Bearing E Fan Sheave F Bushing- Fan Sheave G Belt H Motor Sheave I Motor Motor Tube- Plastic Coupling- Tube.5 x.5 FPT Fitting- Grease Fan Assembly- Complete Fan Assembly- Complete A Damper- Backdraft Quantity= when Inverter model 3500 (Code 5= G) is used. Quantity shown is for fan (Code 4=). Quantities for fan units (Code 4= ): Ref. 5= 5 ; Ref. 53= 4; Ref. 54= 4. 3 Contact Daikin Applied. 4 Quantity is PER fan. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page

23 Section A- Outdoor/Return Air Section Prop Exhaust Fan Control Box Code 0= HE, JE AND Code 4=, Prop Exhaust Fan Control Box & Inverter- (0/03 & Earlier) Inverter- Fan Units (Code 4= ) Voltage Code Inverter Part 5= Number S AFD0- MD AFD0- MD V 30V Inverter- Fan Units (Code 4= ) Voltage Code Inverter Part 5= Number S AFD0- MD AFD0- MD V 30V Note that the original (mid 00 and earlier) VFDs are no longer available. For more information and replacement components, see the Supply Fan Inverter Section 0/3 & Earlier OL5 M5 OL5 M Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload Overload Overload Overload M5, 5 Contactor Contactor V 30V Fan Unit shown Prop Exhaust Fan Control Box & Inverter- (03/03 & Later) Inverter- Fan Units (Code 4= ) Inverter- Fan Units (Code 4= ) Voltage Code Inverter Part 5= Number B AFD0- MD AFD0- MD V 30V Voltage Code Inverter Part 5= Number B AFD0- MD AFD0- MD V 30V The replacement VFD Keypad for MD4 Inverters is p/n is OL5 OL5 M5 M5 Fan Unit shown 0 30 Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload Overload Overload Overload M5, 5 Contactor 5A Contactor 6A Contactor 9A Contactor 7A V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 3

24 LH Louvered Door Assy Section Final Assembly Section A- Outdoor/Return Air Section Design Flow Code 0= JE Louvered Door Assembly Detail RH Louvered Door Assy Design Flow Vane and Vane Bearings Detail Adjuster Control Assy Detail 30 Spring Detail Ref. Part Part Qty. No. Description Number Louver Panel Left Hand Door Louver Panel Right Hand Door Grille Gasket Gasket Potentiometer O Ring- Potentiometer Panel- Vane Shaft- Upper Bearing- Lower Crank Arm Assy Left Hand Door Crank Arm Assy Right Hand Door Link Arm 0 Bearing Bearing Spring- Main.75 x Spring- Secondary.30 x N/S Leveling Kit- Design Flow Quantity is PER door. P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 4

25 Bottom Return Shown Code 9= BY, BE Section A- Outdoor/Return Air Section Section Mounted Controls- OAE, RAE, RAT, SD Economizer Damper 40 4 OAE- Mechanical Enthalpy (Code 7= YY) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n & Mount Minor field modifications are required for proper installation & operation when changing to the newer design. Bottom Return Shown Code 9= BY, BE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE BOTH original controls are obsolete & no longer available. For the OAE Control use & Mount For the RAE Control use & Mount Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay (OAER), are required for proper installation & operation. 7 RAT- Outdoor/Return Air Temperature Sensor Ref. Part Part Qty. No. Description Number 7 Return Air Temp. Sensor- RAT Return Air Opening 30 Return Air Opening SD- Return Air Smoke Detector Code 6= Ref. Part Part Qty. No. Description Number 30 Smoke Detector SD Back Return Code 9= HY Bottom Return Code 9= BY Section B- Draw-Thru Filter Section Section Mounted Controls- PC5 65 Controls PC5 Ref. Part Part Qty. No. Description Number 65 PC5 Pressure Control Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 5

26 Section B- DrawThru Filter/Blank Section Filters Typical Angular Filter Section Shown Code 5= A* Ref. Part Code Part Qty. No. Description 5= Number Angular Filter Section Code 5= A*, D*, E* N/S Filter 30% Pleated, 6 x 5 x " MERV 8 *B % Pleated, 6 x 5 x " w/ Intersept MERV 8 *C % Disposable, 6 x 5 x MERV 3 *H N/S Filter 30% Pleated, 6 x 0 x MERV 8 *B % Disposable, 6 x 0 x w/ Intersept MERV 8 *C % Disposable, 6 x 0 x MERV 3 *H N/S Media Filler Piece ALL N/S Angle Assembly ALL Flat Filter Section Code 5= F*, G*, H* N/S Filter, Cartridge 65% Cartridge, 4 x 4 x " MERV *D % Cartridge, 4 x 4 x " MERV 4 *E % Cartridge, 4 x 4 x " w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x " MERV *D % Cartridge, x 4 x " MERV 4 *E % Cartridge, x 4 x " w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL N/S Pre Filter, x 4 x ALL Staggered Filter Section Code 5= L*, S*, T*, V* 65% Cartridge, 4 x 4 x MERV *D % Cartridge, 4 x 4 x MERV 4 *E % Cartridge, 4 x 4 x w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D % Cartridge, x 4 x MERV 4 *E % Cartridge, x 4 x w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL N/S Pre Filter, x 4 x ALL Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. Optional- Angle is mounted on leaving air side. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 6

27 Small Face Area Coil 4 Section Code 03= S Section D- Draw-Thru Cooling Section Evaporator Coils, Drain Pans, Gasketing 3 4 Section, Small Face Coils- Code 03= S Ref. Part Part Qty. No. Description Number 3 Coil Contact Daikin Applied 0 Drain Pan Galv. C7= CYYY, CYYP Stainless C7= CYYS Pan- Auxiliary Galv. C7= CYYY, CYYP Stainless C7= CYYS Gasket Gasket Section, Large Face Coils: Code 03= L Large Face Area Coil 48 Section Code 03= L Ref. Part Part Qty. No. Description Number 3 Coil- Lower Contact Daikin Applied 4 Coil- Upper Contact Daikin Applied 0 Drain Pan Galv. C7= CYYY, CYYP Stainless C7= CYYS Drain Pan Galv. C7= CYYY, CYYP Stainless C7= CYYS Pan- Liner Pan- Auxiliary Gasket Gasket Gasket Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 7

28 Section E- Draw-Thru Heat Section Hot Water Coil Heat, Mixing Valves and Actuator- VM Code 30= W*** OR W*** Coil Location Mixing Valve Detail Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30= Type Height Number 0 Hot Water Heat Coil- Bottom W*** 5WH090H Hot Water Heat Coil- Bottom W*** 5WS090C Hot Water Heat Coil- Top W*** 5WH090H Hot Water Heat Coil- Top W*** 5WS090C VM Actuator- 4V, Valve W****E All All Actuator- 4V, Valve W****E All All Valve, 3 Way w/ Actuator.5 W**E3* 5WH, 5WS All W**F3* 5WH, 5WS All W**G3* 5WH, 5WS All W**H3* 5WH, 5WS All W**J3* 5WH, 5WS All Note that the Valve is factory supplied WITH the Actuator. Use this p/n when replacing the Actuator only. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 8

29 Section F- Supply Air Section Air Foil Fan- Double Width Code 3= 30A, 30A Wheel Detail (When FACING Discharge opening) 6 5 Ref. Part Part Qty. No Description Number Motor- see table 3 pages after next Housing Assy- Blower Inlet Funnel Only Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CCW Screw Adjust Assembly Shaft-.438 Diameter Motor Mount Assembly Angle- Motor Mount Holddown Angle, Clamping Key- Fan 9.5 Long X 5/8 Diameter 0364 Key- Sheave 6.50 Long X 5/8 Diameter Bearing- Ball.437 Bore Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 9

30 Section F- Supply Air Section Air Foil Fan- Single Width Code 3= 40B, 40B Ref. Part Part Qty. No. Description Number Motor- see table pages after next 3 Wheel, Fan- Single Inlet/Single Width Inlet Funnel Assembly Screw Adjust Assembly Shaft.88 Diameter Mount Assembly-Motor Angle -Motor Mount Angle, Clamping Key- Fan, 4.5 Long X / Diameter 0359 Key- Fan, 5.50 Long X / Diameter Tubing- Plastic Bearing- Ball.87 Bore Fitting- /4 OD X /8 MPT Fitting- /4 OD X /8 FPT Bearing- Ball.87 Bore Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 30

31 Section F- Supply Air Section Fan Mounts- 30 Airfoil Double Width Fan Code 3= 30A, 30A3 6 or 6 Mount Locations 63 or 63 6 or 6 64 or Rubber Mounts Rubber Mounts (Code 3= 30A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support , 5 Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Red , 50 Rubber Mount- Green Rubber Mount- Black Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Mount- Purple Seismic strap used only when Code 3= 30A Seismic Spring (Code 3= 30A3) Spring Mount- Brown Spring Mount- Red All Spring Mount- Purple , 7.5 Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black All Spring Mount- Brown All Nut All Nut All Screw Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 3

32 Section F- Supply Air Section Fan Mounts- 40 Airfoil Single Width Fan Code 3= 40B, 40B3 Mount Locations 6 or 6 6 or 6 64 or or Rubber Mounts Rubber Mounts (Code 3= 40B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts Seismic strap used only when Code 3= 40B Seismic Spring (Code 3= 40B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Mount- Purple Spring Mount- Brown All Spring Mount- Black Spring Mount- Purple Spring Mount- Brown Spring Mount- Red Spring Mount- Purple , 50 Spring Mount- Brown All Nut All Nut All Screw Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 3

33 Section F- Supply Air Section Supply Air Fan Motors H.P. Motor H.P. Unit ODP PrEff. Code 3= Voltage C3= *JY C09= 3 H** 08/60/ J** 08/60/ K* 08/60/ L** 08/60/ M** 08/60/ N** 08/60/ P** 08/60/ Q** 08/60/ R** 08/60/ S** 08/60/ C09= 9 3 H** 30/60/ J** 30/60/ K** 30/60/ L** 30/60/ M** 30/60/ N** 30/60/ P** 30/60/ Q** 30/60/ R** 30/60/ S** 30/60/ C09= 7 3 H** 460/60/ J** 460/60/ K** 460/60/ L** 460/60/ M** 460/60/ N** 460/60/ P** 460/60/ Q** 460/60/ R** 460/60/ S** 460/60/ C09= 37 3 H** 575/60/ J** 575/60/ K** 575/60/ L** 575/60/ M** 575/60/ N** 575/60/ P** 575/60/ Q** 575/60/ R** 575/60/ S** 575/60/ Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 33

34 Section F- Supply Air Section Inverters Code 5= S: MD, MD3, MD6 Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number , , , , , , , In 00 the original ATV drives were replaced with ATV drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV Remote Keypad is p/n The ATV Lonworks communication card is p/n The ATV Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The ATV Lonworks communication card is p/n All other ATV communication cards are integral to the VFD and are not available separately. Note that since the original ATV drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV part fails, the entire drive must be replaced. MD3 Remote Keypad p/n is For units with an MD3 Inverter and Motor 0 HP or smaller a Line Reactor will be automatically installed. See the table one page after next for Line Reactor part numbers. 4 MD6 Remote Keypad p/n is plus Mount p/n Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 34

35 Section F- Supply Air Section Inverters Code 5= B: MD4, MD5 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number The replacement VFD Keypad for MD4 & MD5 Inverters is p/n is Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 35

36 Section F- Supply Air Section Line Reactors 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number Line Reactors are optional except for units (Code 09= 37), when Code 5= S, AND the Inverter is 0HP or smaller. These are 5% impedance line reactors. Some units may have 3% impedance line reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. 3 Not available for this HP and voltage. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 36

37 Section F- Supply Air Section Section Mounted Controls- PC7, HL, EFT, OAT, DAT PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket 9 Pressure Control- PC7 0 Pneumatic Fitting In mid 0 the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 9043 for proper installation as old and new parts are NOT interchangeable. The Switch only is p/n , the Pneumatic Fitting is p/n 9044, and the Support Bracket is p/n HL- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 67 T-stat- HL Hi Limit Entering Fan Temperature Sensor- EFT EFT Ref. Part Part Qty. No. Description Number 5 EF Temp. Sensor- EFT DAT Discharge Air Temperature Sensor- DAT Ref. Part Part Qty. No. Description Number 8 DA Temp. Sensor- DAT Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor- OAT OAT Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 37

38 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Heaters, Diffusers, Hi Limit Cutouts HL- 0, 3-50 Diagram 5 Air Flow 7 7A 6 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 38

39 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Heaters, Diffusers, Hi Limit Cutouts HL- 0, 3-50 Components Unit Volt. Ref. Sch. Part Total Code Heater Part No. Sym. Description KW 34= KW Number 5 Heater Assy- Top 40 E Heater Assy- Top 40 E Heater Assy- Top 60 E Heater Assy- Top 60 E Heater Assy- Top 80 E Heater Assy- Top 80 E Heater Assy- Top 00 E Heater Assy- Top 00 E Heater Assy- Top 0 E Heater Assy- Top 0 E Heater Assy- Top 60 E Heater Assy- Top 60 E Heater Assy- Top 00 E Heater Assy- Top 00 E Heater Assy- Top 40 E Heater Assy- Top 40 E Blank Assy- Bottom E/ Heater Assy- Bottom 00 E Heater Assy- Bottom 00 E Heater Assy- Bottom 40 E Heater Assy- Bottom 40 E HL-0 Hi Limit- Manual Cutout All All All var var 7A HL3-50 Hi Limit- Auto Cutout All All All var var Diffuser All All All /30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 39

40 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box Diagrams & Components- (0/03 & Earlier) FB33 FB37 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB33 FB3 FB3 M33 M37 M3 M36 M3 M35 FB34 FB38 H S 3 M33 M3 M3 FB34 H S 3 M33 M3 FB4 M3 FB4 H S 3 T B M34 T B M4 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 DS3 or PB3 DS3 or PB3 08/30V 0KW- 60KW 460/ 0KW- 60KW 460/ 00KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Amps Switch Handle Shaft Lug Kit DS3 Disconnect Switch 00 Amp Disconnect Switch 50 Amp Disconnect Switch 50 Amp Disconnect Switch 400 Amp Disconnect Switch 600 Amp , Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Includes Mechanism (except 600A switch, see footnote #4). 3 Note that the original disconnect switch is obsolete. Due to dimensional differences minor field modifications may be required for proper installation. 4 Handle only p/n ; Mechanism only p/n ; Shaft only p/n Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 40

41 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 0-0KW Components- (0/03 & Earlier), Continued Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block 3 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V HS3 Switch TB Terminal Block M3 Contactor Contactor M3 Contactor Contactor M33 Contactor Contactor M34 Contactor Contactor M35 Contactor M36 Contactor Part number is for one section. The number of sections used is determined by the options installed. See chart on previous page. 3 Not used when PB3 Power Block connection is present. 4 Cover- PB3 for 600A DS3 is p/n Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 4

42 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 0-0KW Components- (0/03 & Earlier), Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 4

43 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 60-00KW Components- (0/03 & Earlier) Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block 3 used w/00a/50a DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch HS3 Switch TB Terminal Block V 30V M3 Contactor M3 Contactor M33 Contactor M34 Contactor M35 Contactor M36 Contactor M37 Contactor M38 Contactor M4 Contactor M4 Contactor Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Not used when PB3 Power Block connection is present. 4 Cover- PB3 for 600A DS3= p/n Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 43

44 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 60-00KW Components- (0/03 & Earlier), Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block FB37 Fuse Block FB38 Fuse Block FB4 Fuse Block FB4 Fuse Block V 30V F3 Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB F37 Fuse- FB F38 Fuse- FB F4 Fuse- FB Fuse- FB F4 Fuse- FB Fuse- FB Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 44

45 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box Diagrams & Components- (03/03 & Later) FB33 FB37 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB33 FB3 FB3 M33 M37 M3 M36 M3 M35 FB34 FB38 H S 3 M33 M3 M3 FB34 H S 3 M33 M3 FB4 M3 FB4 H S 3 T B M34 T B M4 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 DS3 or PB3 DS3 or PB3 08/30V 0KW- 60KW 460/ 0KW- 60KW 460/ 00KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 00A Not Used Not Used Disconnect Switch- 50A Disconnect Switch- 50A Disconnect Switch- 400A Disconnect Switch- 600A Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. This Shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This Shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 45

46 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 0-0KW Components- (03/03 & Later), Continued Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block 75A Power Block 40A PB3 Power Block 3 75A Power Block 3 40A DS3 Disconnect Switch 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V HS3 Switch TB Terminal Block M3 Contactor 40A Contactor A M3 Contactor 40A Contactor A M33 Contactor 40A Contactor A M34 Contactor 40A Contactor A M35 Contactor 40A M36 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. See the chart on the previous page. 3 Not used when PB3 Power Block connection is present. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 46

47 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 0-0KW Components- (03/03 & Later), Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 47

48 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 60-00KW Components- (03/03 & Later) Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block Power Block DS3 Disconnect Switch 08V 30V HS3 Switch TB Terminal Block M3 Contactor 40A M3 Contactor 40A M33 Contactor 40A M34 Contactor 40A M35 Contactor 40A M36 Contactor 40A M37 Contactor 40A M38 Contactor 40A M4 Contactor 40A M4 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Not used when PB3 Power Block connection is present. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 48

49 Section G- Blow-Thru Heat Section Electric Heat: Code 04= E Electric Heat Control Box 60-00KW Components- (03/03 & Later), Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block FB37 Fuse Block FB38 Fuse Block FB4 Fuse Block FB4 Fuse Block V 30V F3 Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB F37 Fuse- FB F38 Fuse- FB F4 Fuse- FB Fuse- FB F4 Fuse- FB Fuse- FB Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 49

50 Section G- Blow-Thru Heat Section Gas Heat: Code 04= A Vestibules, Heat Exchangers and Primary Components Heat Exchanger 300 Burner 3 Burner Control Box 4 Gas Train 5 Ref. Part Qty. No. Description MBH MBH MBH 300 Heat Exchanger Kit Vestibule Vestibule N/S Turbulator N/S= Not shown on diagram. Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket. Quantity varies depending upon the size of the Heat Exchanger. For 400 MBH order 6 pc.; for 640 MBH order 9 pc.; for 790 MBH order pc. Note that the required Turbulators are NOT included in the Heat Exchanger Kits. 3 Parts detail follows this section. 4 Parts detail follows Burner section. 5 Parts detail follows Burner Control Box section. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 50

51 Section G- Blow-Thru Heat Section Gas Heat: Code 04= A AND Code 34= ***SE* Modulating Burner Diagrams Burner Control Box Pilot Valve/ Pressure Regulator Assy Detail 60 6 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 5

52 Section G- Blow-Thru Heat Section Gas Heat: Code 04= A AND Code 34= ***SE* Modulating Burner Components Ref. Part Part Qty. No. Description Number 0 Burner Housing Scroll Wheel-.5 bore Motor-.5 HP, 5/60/ Gun Assembly 400 MBH Furnace MBH Furnace MBH Furnace Inlet Funnel Fan Guard Blast Tube 400 MBH Furnace MBH Furnace MBH Furnace Pilot Mixer Pilot Assembly Damper Assembly Blast Tube Gasket Right Side Damper 400 MBH Furnace MBH Furnace MBH Furnace Left Side Damper 400, 640 MBH Furnace MBH Furnace Slide Damper 400 MBH Furnace MBH Furnace MBH Furnace Blower Gasket Burner Cover Ignition Assembly 0 Glass Cover Glass Cover Support Orifice 400 MBH Furnace MBH Furnace MBH Furnace Clip Flange Bearing Air Switch Tube Pilot Burner Tube 400 MBH Furnace , 790 MBH Furnace Compression Fitting Pilot Tube Burner Box Baffle 400 MBH Furnace , 790 MBH Furnace Valve- Pressure Regulator Valve- Solenoid N/S Flame Rod N/S Ignition Electrode Assy N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 5

53 Section G- Blow-Thru Heat Section Gas Heat: Code 04= A Burner Controls R3B IT 5 4 R3A Gas Control Box FSG Detail R0A AS TB FLC Panel Detail S3 GV Detail FSG 5 Ref. Sch. Part Part Qty. No. Sym. Description Number GV Pressure Reg. Assy Valve Only Solenoid Valve Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard Time Delay 90 Seconds S3 Toggle Switch- 4PST IT Ignition Transformer AS Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper R0A Relay- High Amp DPDT/0V R3A Relay- High Amp DPDT/0V R3B Relay- Low Amp DPDT/0V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 53

54 Section G- Blow-Thru Heat Section Gas Heat: Code 04= A Gas Train Inlet, Gas Train- Controls: GV, GV3, & Gas Train Outlet Gas Train- Inlet MBH Ref. Part Part Qty. No. Description Number 05 Shutoff Valve MBH Gas Valve 400 MBH , 790 MBH Gas Train- Controls: GV, GV GV GV Ref. Part Part Qty. No. Description Number 48 Gas Valve- GV, GV3 400 MBH , 790 MBH Pressure Regulator 400 MBH , 790 MBH Junction Box Junction Box Cover Gas Pipe 400 MBH MBH MBH Gas Train- Outlet Ref. Part Part Qty. No. Description Number 75 Pipe w/ Valve Mount 400 MBH , 790 MBH Butterfly Valve 400 MBH , 790 MBH Shutoff Valve 400 MBH , 790 MBH Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 54

55 Section G- Blow-Thru Heat Section Gas Heat: Code 04= A Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly 400 MBH MBH MBH Inspection Door Back- Flue Box 400 MBH MBH MBH Angle- Flue Box 400 MBH MBH MBH Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket Hinge Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 55

56 Section K- Discharge Plenum Section Section Mounted Controls OAT, DAT, AND Access Door Latching Assemblies, Key, & Lock 7 8 OAT DAT Discharge Air Temperature Sensor- DAT & Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 Outdoor Air Temp. Sensor- OAT Discharge Air Temp. Sensor- DAT Access Door Latching Assemblies, Key, & Lock (All Sections) Ref. Part Part Qty. No. Description Number 0 Door Latching Assy.- LH, 73" Section 4 var. 0 Door Latching Assy.- RH, 73" Section 4 var. N/S Access Door Key var. N/S Access Door Lock 0370 var. N/S= Not Shown on diagram. These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. 0 0 Door Latching Assy. Left Hand Door Latching Assy. Right Hand Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 56

57 Section M- Condenser Section Condenser Fan Deck Assembly 06E, 06E Diagrams Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail 50 Fan # Fan # 5 Fan # 3 Fan # 3 Fan # End of Unit Fan # 06, 06 Fan Deck Detail Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 57

58 Section M- Condenser Section Condenser Fan Deck Assembly 06E, 06E Components 08/30V Unit Size Ref. Part Part No. Description Number Condenser Coils Code 43= M* x 7 7/3 & Earlier NA NA NA x 7 3/4 & Later Condenser Coils Code 43= T* 33.5 x Condenser Coils, Coated Code 43= P* x Condenser Coils, Coated Code 43= U* x Top Panel Motor- Condenser, Fantrol AND Speedtrol, Motor- Condenser, Fantrol AND Speedtrol Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit N/S= Not shown on Diagram. Due to production overlap, between 8/3 and /4 either coil OR may be installed. If ALL coils are to be replaced use p/n For units built between 8/3 and /4 contact Daikin Applied with serial number information so that the correct coil can be identified. Note that 06E units replaced 06E units in late 05. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications. 3 Code 47= OR. 4 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. 08/30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 58

59 Section M- Condenser Section Condenser Fan Deck Assembly 070E, 075E Diagrams Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail 50 Fan # 3 55 End of Unit Fan # End of Unit Fan # 3 5 Fan # Fan # Fan # 070D Fan Deck Detail Fan # Fan # Fan # 4 Fan # 4 Fan # (075 shown) Fan # 3 Fan # Fan # 3 End of Unit 075D Fan Deck Detail Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 59

60 Section M- Condenser Section Condenser Fan Deck Assembly 070E, 075E Components Unit Sizes Ref. Part Part No. Description Number Condenser Coils 5/3 & Earlier 5 Coil- Condenser, Standard, 3 x 84 Code 43= M* Condenser Coils 5 Coil- Condenser, Coated, 3 x 84 Code 43= P* Panel- Blank Top Panel Motor- Condenser, Fantrol AND Speedtrol, Motor- Condenser, Fantrol AND Speedtrol Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit N/S= Not shown on Diagram. For units built 6/3 & Later contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications. 3 Code 47= OR. 4 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. 08/30V 08/30V 460/V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 60

61 Section M- Condenser Section Condenser Fan Deck Assembly Compressors & Compressor Components Unit Size 06E, 06E Side View Compressor Rail to Base Channel Mounting Detail (6 places) Compressor Rail or Compressor Mounting Channel Unit Size Ref. Part Part No. Description Number, Compressors- Circuits # or 4/4 & Earlier Compressors- Circuits # or 5/4 & Later Compressors- Circuits # or 4/4 & Earlier Compressors- Circuits # or 5/4 & Later Compressors- Circuits # or 4/4 & Earlier Compressors- Circuits # or 5/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Heater- Crankcase NOTE: Quantities listed are for the unit. Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. Note that the 06E replaced the 06E in late /30V 08/30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 6

62 Section M- Condenser Section Condenser Fan Deck Assembly- Compressors & Compressor Components Unit Size 070E, 075E or Side View Discharge Tubing 45 Gas Tubing Suction Tubing Circuit # Comp. # Comp. #3 Comp. #5 or or or or Circuit # Comp. # Comp. #4 Comp. #6 Compressor to Compressor Rail Mounting Detail 75 Circuit # or Circuit # Top View 0 Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 30 Compressor Rail to Base Channel Mounting Detail (8 places) Compressor Rail Compressor Mounting Channel Unit Size Ref. Part Part No. Description Number, Compressors- Circuits # OR Trio Compressors- Circuits # OR Trio Compressors- Circuits # OR Trio Compressors- Circuits # OR Trio Compressors- Circuits # OR Trio Compressors- Circuits # OR Trio Grommet Sleeve Screw Washer- Plain Washer- Lock Sight Glass- Gas Line Junction Box- Compressor Fitting- Rotolock Heater- Crankcase Screw- Junction Box Gasket- Junction Box Rail- Trio Compressor Mounting Spacer Screw Washer Quantities are PER unit. Each circuit has equal quantities of each part. 6 feet per junction box. 08/30V 08/30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 6

63 Section M- Condenser Section Pressure Controls Box- 06E AFD, AFD, LR, LR, LP, LP, HP, HP 0/3 & Earlier 44 HP SPTRL typ. AFD AFD 35 HP 46 LP SPTRL LP LR LR Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure Fantrol Unit Code 47= Speedtrol Unit Code 47= HP, Switch- High Pressure SPTRL Switch- Speedtrol Pressure Code 47= Valve Core Valve Cap Fantrol Unit Code 47= Speedtrol Unit Code 47= AFD, Inverter 08/30V Inverter Inverter LR, Line Reactor only (Code 09= 37) This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. On Fantrol units, there is a Valve Core (Ref. # 38) and Valve Cap (Ref. # 39) in place of each of the SPTRL Switches. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 63

64 Section M- Condenser Section Pressure Controls Box- 06E, 06E AFD, AFD, LR, LR, LP, LP, HP, HP 03/3 & Later See Factory Supplied Line Voltage Box Section Ref. Sch. Part Part Qty. No. Sym. Description Number 33, 34 LP, Switch- Low Pressure Fantrol Unit Code 47= Speedtrol Unit Code 47= HP, Switch- High Pressure SPTRL Switch- Speedtrol Pressure Code 47= Valve Core Valve Cap Fantrol Unit Code 47= Speedtrol Unit Code 47= , 44 AFD, Inverter 08/30V Inverter Inverter On Fantrol units, there is a Valve Core (Ref. # 38) and Valve Cap (Ref. # 39) in place of each of the SPTRL Switches. The replacement VFD Keypad is p/n For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 64

65 Section M- Condenser Section Pressure Controls Box- 070E, 075E AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 0/3 & Earlier 44 HP PC SPTRL typ PC3 AFD AFD 35 HP 46 LP SPTRL LP LR LR Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure Fantrol Unit Code 47= Speedtrol Unit Code 47= HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- Speedtrol Pressure Code 47= Valve Core Valve Cap Fantrol Unit Code 47= Speedtrol Unit Code 47= AFD, Inverter 08/30V Inverter Inverter LR, Line Reactor only (Code 09= 37) This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. On Fantrol units, there is a valve core (Ref. # 38) and valve cap in place of each of the SPTRL switches. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 65

66 Section M- Condenser Section Pressure Controls Box- 070E, 075E AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 03/3 & Later See Factory Supplied Line Voltage Box Section Ref. Sch. Part Part Qty. No. Sym. Description Number 33, 34 LP, Switch- Low Pressure Fantrol Unit Code 47= Speedtrol Unit Code 47= HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- Speedtrol Pressure Code 47= Valve Core Valve Cap Fantrol Unit Code 47= Speedtrol Unit Code 47= , 44 AFD, Inverter 08/30V Inverter Inverter On Fantrol units, there is a valve core (Ref. # 38) and valve cap in place of each of the SPTRL switches. The replacement VFD Keypad is p/n For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 66

67 Section M- Condenser Section Factory Supplied Line Voltage Box- Code 3= YY*FY (Powers Receptacle and Lights) T6, DS6, FU6A, FU6B, FU6C 0/3 & Earlier 9 T6 DS6 8 L L L3 3 FU6C FU6B FU6A T T T3 Voltage Ref. Sch. Part Part No. Sym. Description Number T6 Transformer KVA Transformer KVA Transformer KVA V 30V 3 DS6 Disconnect Switch 30A/600V FU6A,B Fuse 0A/600V Fuse 0A/600V Fuse 8A/600V FU6C Fuse 0A/600V /3 & Later Voltage Ref. Sch. Part Part No. Sym. Description Number 47 T6 Transformer KVA Transformer KVA Transformer KVA N/S - Finger Safe Cover Kit N/S DS6 Fuse Holder/Circuit Protector P, 30A, 600V N/S FU6A,B Fuse 0A/600V Fuse 0A/600V Fuse 8A/600V N/S FU6C Fuse 0A/600V N/S Fuseblock P, 30A, 500V N/S Fuse Cover/Puller N/S= Not Shown on Diagram. Located in the Pressure Controls Box. pc. PER Fuse. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 67

68 Section N- Main Control Box Control Panel- MicroTech III Diagram- (0/03 & Earlier) TB R R R R R R R R R R R R 63 R R 8 8 R 83 R 84 R 85 R 86 R 87 R 88 COM MCB EXP A EXP B SPS SPS TD 0 HSS T3 T S4 S7 DHL See Power Panel The above diagram shows a typical Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 68

69 Section N- Main Control Box Control Panel- MicroTech III Control Box Component Label Diagram- (0/03 & Earlier) Note that starting in late 00 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 69

70 Section N- Main Control Box Control Panel- MicroTech III Components- (0/03 & Earlier) Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad Remote Interface Display Expansion Module EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Communication Card COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge Code = LE, LW LonWorks- Constant Volume Code = LF Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units DPST/5A Electric, HW or No Heat SPST/0A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Duct Hi Limit and Duct Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer Kit- Duct Sensor (9/ & Earlier) 3, Pressure Transducer- Duct Sensor (0/ & Later) Pressure Transducer Kit- Space Sensor (9/ & Earlier) 3, Pressure Transducer- Space Sensor (0/ & Later) Not Shown on diagram. Quantity varies depending upon unit options selected. 3 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. 4 As of 09/ the original Pressure Transducer is no longer available. The Transducer Kit includes Transduc er, Dinrail, Resistor, Sampling Tube, and installation Instructions. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 70

71 Section N- Main Control Box Control Panel- MicroTech III Components- (0/03 & Earlier), Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- Speedtrol inverter AFD R Relay- Condenser Fan R3 Relay- Condenser Fan R4 Relay- Condenser Fan R0 Relay- Heat R Relay- Gas Heat R4 Relay- Gas Heat Alarm R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4= R63 Relay- Duct Hi Limit Units with Return Fan Inverter 3PDT/0V Units with No Return Fan Inverter DPDT/0V R8 Relay- Inverter Reset 4P/6A/4V R8 Relay- Inverter Reset 4P/6A/4V R83 Relay- Smoke 4P/6A/4V R84 Relay- Smoke 4P/6A/4V R85 Relay- Smoke 4P/6A/4V R86 Relay- Smoke 4P/6A/4V R87 Relay- Smoke 4P/6A/4V R88 Relay- Smoke 4P/6A/4V Time Delays TD0 Time Delay Return Air Fan Terminal Block TB Terminal Block Sensors ZNT Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only- Code = *F, *W. 3 Not Shown on diagram. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 7

72 Section N- Main Control Box Power Panel Diagrams- (0/03 & Earlier) See Control Panel See Control Panel FB FB T F F3 F.A F.B FC PL - PL43 Plugs MMP0 M0 MMP MMP 3 M M M3 M4 PB PB REC MMP MMP 3 M M M3 M4 TB3 TB4 TB MMP M MMP 3 M3 MMP 5 M5 MMP M MMP 4 M4 MMP 6 M6 DS or PB TB7 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 7

73 Section N- Main Control Box Power Panel Terminal Blocks, T Transformer & Fusing, Fuses, Plugs- (0/03 & Earlier) Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB,3,4,7 Terminal Block Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,W,Y Electric, Hydronic, No Heat Code 04= E,W,Y Electric, Hydronic, No Heat Code 04= E,W,Y Gas Heat Code 04= A Gas Heat Code 04= A Gas Heat Code 04= A Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Electric, Hydronic, No Heat Code 04= E,S,W,Y Electric, Hydronic, No Heat Code 04= E,S,W,Y Electric, Hydronic, No Heat Code 04= E,S,W,Y Gas Heat Code 04= A Gas Heat Code 04= A Gas Heat Code 04= A Gas Heat Code 04= A FC Fuse- T Transformer Gas Heat Code 04= A Electric, Hydronic, No Heat Code 04= E,S,W,Y F,F3 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor Code 04= A PL- 43 Plugs Pin Plug varies varies varies varies 5 6 Pin Plug varies varies varies varies 6 Pin Plug varies varies varies varies 7 3 Pin Cap Kit varies varies varies varies 8 6 Pin Cap Kit varies varies varies varies 9 9 Pin Cap Kit varies varies varies varies 0 5 Pin Cap Kit varies varies varies varies Varies depending on unit options. Part number is for one individual section. Ground Block is p/n When required TB, 3, 4, or 7 use Jumpers p/n ( pole), (3 pole), (4 pole), (5 pole). All T Transformers also use Fuse Puller Kit p/n & Cover Kit p/n All possible Plugs used are listed. Check actual unit to verify which Plug is required. 4 Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 5 Used with Strain Relief (p/n ) & 6 pin cap kit (p/n ). Used for PL0, PL. 6 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 7 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 8 Used for PL9, PL0. 9 Used for PL8, PL9, PL35, PL36, PL43. 0 Used for PL7, PL8. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 73

74 Section N- Main Control Box Power Panel Fusing, Phase Protection, Power Blocks- (0/03 & Earlier) Sch. Part Part Voltage Sym. Description Number 08V 30V Power Blocks PB Power Block- Main Code = P Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 40A Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat KW Electric Heat KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 74

75 Section N- Main Control Box Power Panel Receptacle, Disconnect Switch- (0/03 & Earlier) Sch. Part Part Voltage Sym. Description Number 08V 30V Receptacles REC Receptacle Disconnect Switch DS Disconnect Switch- Main Switch- 00A Handle Kit Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 600A Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. Note that the original Disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper installation. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 75

76 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Detail Diagrams- (0/03 & Earlier) Front Mtd. Contact 3E Link 3B 3 MMP Contactor MMP 3 3E Contactor Front Mounted Contact MMP 3 Lug Trip Indicator Alarm Contactor 3F 3G MMP0 & M0 Link Detail 3, 5, 7.5 HP Motors- All Voltages 0 HP Motor- 30/460/ 5, 0 HP Motor- 460/ 5, 30 HP Motors- MMP0 & M0 Link Detail 0HP Motor- 08V 5HP Motor- 08/30V 0 HP Motors- 08/30V 5 HP Motors- 30/ 30 HP Motors- 40 HP Motors- 460/ 50 HP Motors- 460/ MMP0 & M0 Link Detail 5 HP Motors- 08V 30 HP Motors- 30V NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Lug 3G 3G Lug MMP 3 3 MMP Trip Ind. Interlock 3F 3F Trip Ind. Interlock Contactor Contactor MMP0 & M0 Link Detail 30 HP Motors- 08V 40 HP Motors- 08/30V 50 HP Motors- 30V MMP0 & M0 Link Detail 50 HP Motors- 08V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 76

77 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Components- (0/03 & Earlier) 3 HP Motor- Code 3= HJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Aux. Contact- NC OR NO V 30V 5 HP Motor- Code OR 3= JJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply OR Exhaust Fan Contactor- Supply OR Exhaust Fan MMP0, 0 MMP- Supply OR Exhaust Fan MMP- Supply OR Exhaust Fan MMP- Supply OR Exhaust Fan B Link E Aux. Contact- NC OR NO V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 77

78 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Components- (0/03 & Earlier), Continued 7.5 HP Motor- Code 3= KJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Aux. Contact- NC OR NO V 30V 0 HP Motor- Code 3= LJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Aux. Contact- NC OR NO V 30V 5 HP Motor- Code 3= MJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Aux. Contact- NC OR NO V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 78

79 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Components- (0/03 & Earlier), Continued 0 HP Motor- Code 3= NJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Aux. Contact- NC OR NO V 30V 5 HP Motor- Code 3= PJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Aux. Contact- NO or NC F Trip Indicator Interlock G Lug (3 per kit) V 30V 30 HP Motor- Code 3= QJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Aux. Contact- NC OR NO F Trip Indicator Interlock G Lug (3 per kit) V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 79

80 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Components- (0/03 & Earlier), Continued 40 HP Motor- Code 3= RJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan E Aux. Contact- NC OR NO F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 ring terminals. 08V 30V 50 HP Motor- Code 3= SJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan E Aux. Contact- NC OR NO F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 ring terminals. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 80

81 Section N- Main Control Box Power Panel Unit Size 06E: Compressor MMP- 4 and Contactor M- 4- (0/03 & Earlier) MMP 3 Front Mounted Contact 3E Front Mounted Contact 3E 3 MMP Contactor Link 3B Front Mounted Contact A Front Mounted Contact A Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 4 & M- 4 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor M- 4 Contactor- Compressor A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr B Link E Front Mounted Contact- NO /30V 06 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 8

82 Section N- Main Control Box Power Panel Unit Size 070E: Compressor MMP- 6 and Contactor M- 6- (0/03 & Earlier) MMP 3 Front Mounted Contact 3E Front Mounted Contact 3E 3 MMP Contactor Link 3B Front Mounted Contact A Front Mounted Contact A Contactor MMP- 6 & M- 6 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor M- 6 Contactor- Compressor A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 6 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr B Link E Front Mounted Contact- NO /30V 070 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 8

83 Section N- Main Control Box Power Panel Unit Size 075E: Compressor MMP- 6 and Contactor M- 6- (0/03 & Earlier) MMP 3 Front Mounted Contact 3E Front Mounted Contact 3E 3 MMP Contactor Link 3B Front Mounted Contact A Front Mounted Contact A Contactor MMP- 6 & M- 6 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor M- 6 Contactor- Compressor A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 6 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr B Link E Front Mounted Contact- NO /30V 075 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 83

84 Section N- Main Control Box Power Panel Condenser Fan MMP,, 3,,, 3 & Contactors M- 4 Fantrol Units (Code 47= )- (0/03 & Earlier) MMP 8 8 MMP Link 8B 8B Link 7 One Contactor Arrangement 7A Spacer Contactor 8C Bus Bar Contactor 7 7A Spacer Two Contactor Arrangement 06, Ref. Sch. Part Part No. Symbol Description Number Contactors & Parts 7 M- 4 M- 4 Contactor- Cond. Fan A Spacer Fan MMP s & Parts 8 MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector NA NA Manual Motor Protector NA NA Manual Motor Protector NA NA MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector NA NA Manual Motor Protector NA NA Manual Motor Protector NA NA MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP C Bus Bar NA NA NA Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 84 08/30V 08/30V

85 Section N- Main Control Box Power Panel Condenser Fan MMP- 4, Contactors M- 4, Fuses F, F Speedtrol Units (Code 47= )- (0/03 & Earlier) MMP & Contactors Detail Speedtrol Fuses MMP 8 Adapter 4 8 MMP Link 8B Puller 8B Link 7A Spacer 8C Bus Bar 7A Spacer 3 Fuse Block 7 Contactor Contactor 7 Fuse One Contactor Arrangement Two Contactor Arrangement 06, F OR F Ref. Sch. Part Part No. Symbol Description Number Speedtrol Fusing F, Fuse Block Fuse Cover/Puller F, Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol Dinrail Adapter Cond. Fan Contactors 7 M- 4 Contactor- Cond. Fan A Spacer Fan MMP s & Parts 8 MMP Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP C Bus Bar NA NA NA NA Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 08V 30V 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 85

86 Section N- Main Control Box Control Panel- MicroTech III Diagram- (03/03 & Later) See Power Panel See Power Panel See Power Panel The above diagram shows a typical Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 86

87 Section N- Main Control Box Control Panel- MicroTech III Control Box Component Label Diagram- (03/03 & Later) GOI Number: H R0 MB= Main Box; BB= Bypass Box; EB= Electric Heat Box; GB= Gas Box; PB= Prop Exhaust Box; Location Device ID McQuay Part # Description GB AS Ctrl-press air switch gas burner GB AS Conduit fitting nipple GB FLC Control Temp Fan Limit Gas Heat GB FSG Ctrl-temp flame safegrd base GB FSG Ctrl-temp Flame Safegrd Control GB FSG Ctrl-temp flame safegrd amplifier GB FSG Ctrl-temp flame safegrd timer 90 GB IT Transformer Ignition GB R0A DPDT Relay 5A 0VAC GB R0A Mounting Adapter P Relay to Dinra GB S Switch Toggle 4PST 5V MB DHL Pressure Switch SPDT MB DS Circuit Breaker Molded Case Switch MB DS lug kit, 3 pcs with power control t MB DS Connector -4 quick connect tab MB DS lug kit, 3 pcs, T3 Frame, 5A MB DS SCREW, PANHEAD AB-type, #8-8 X 3" MB DS Circuit Breaker Operating Mechanism MB DS 9340 HANDLE, PISTOL, ABB DISCONNECT, RED MB DS Fuse holder, Circuit Protector, P MB DS Fuse 0A Rejection Type MB EXP-B Extension I-O 5 Points MB EXP-B Connector for extension I-O - Direc MB FA Fuse 8A Rejection Type MB FB Fuse 8A Rejection Type MB FC Fuse 5A Midget Non-Rejection Ty MB F Fuse 5A Midget Non-Rejection Ty MB FB Fuse 00A 600V Class J Fast Acti MB FB Fuse 35A 600V Class J Fast Actin MB M Contactor IEC 40A 0VAC Coil Screw MB M Contactor Auxiliary Contact NO NC MB M MMP to Contactor Link Module Size S MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor IEC 40A 0VAC Coil Screw MB M Contactor Auxiliary Contact NO NC MB M MMP to Contactor Link Module Size S MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor IEC 40A 0VAC Coil Screw MB M Contactor Auxiliary Contact NO NC MB M MMP to Contactor Link Module Size S MB M Contactor IEC 40A 0VAC Coil Screw MB M Contactor Auxiliary Contact NO NC MB M MMP to Contactor Link Module Size S MB MCB Base Controller with IP and Inbuilt MB MMP MMP Class 0 Size S to 3A MB MMP MMP Auxiliary Contact Sizes S and MB MMP MMP Bus Bar Position No Lateral A MB MMP MMP Bus Bar Type E Feeder Terminal MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Bus Bar 3 Position No Lateral A MB MMP MMP Bus Bar Type E Feeder Terminal MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Class 0 Size S to 3A MB MMP MMP Auxiliary Contact Sizes S and MB MMP MMP Bus Bar Position No Lateral A MB MMP MMP Bus Bar Type E Feeder Terminal MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Bus Bar 3 Position No Lateral A MB MMP MMP Bus Bar Type E Feeder Terminal MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Class 0 Size S to 3A MB MMP MMP Auxiliary Contact Sizes S and MB MMP MMP Class 0 Size S to 3A MB MMP MMP Auxiliary Contact Sizes S and MB OAER DPDT Relay 0A 4VAC MB OAER Relay Socket DPDT MB PB Distribution Power Terminal Brd 7 MB PVM 000 3PH Monitor VAC MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R PDT Relay 0A 0VAC MB R Relay Socket 3PDT MB REC Receptacle Ground Fault Interrupter MB RES RESISTOR 500 Ohm -8 Watt % Pr MB RES RESISTOR 000 Ohm -8 Watt % Pr MB RES RESISTOR 500 Ohm -8 Watt % Pr MB S Switch Toggle DPST 5V MB S Switch Toggle position ON-ON S MB SPS SENSOR, AIR PRESSURE/VELOCITY, DIN MB SPS SENSOR, AIR PRESSURE/VELOCITY, DIN MB T MICRON Transformer, CPT, W/ FB, 50 MB T Cover, Terminals, Micron 6-terminal MB T Cover, Fuseholder, Micron Type Tr MB T Washer, /4" Flat MB T Washer, Split Lock MB T Transformers 75va 0V-4Vac MB T Transformers 75va 0V-4Vac PB M Contactor IEC 9A 0VAC Coil Spring PB M Contactor IEC 9A 0VAC Coil Spring PB OL Overload Relay Class 0 Size S00 5. PB OL Overload Relay Class 0 Size S00 5. Note that units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 87

88 Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole MicroTech III Remote Unit Keypad Remote Interface Display Terminal Block, MCB- 8 Pole Expansion Module EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Communication Card COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge Code = LE, LW LonWorks- Constant Volume Code = LF Phase Voltage Monitor (PVM) Code 7= CP, YP) PVM Phase Voltage Monitor, 08- /6 & Earlier 000 Phase Voltage Monitor, /6 & Earlier 000 Phase Voltage Monitor, 08- /7 & Later Phase Voltage Monitor, /7 & Later Socket, PVM /7 & Later Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Section N- Main Control Box Control Panel- MicroTech III Components- (03/03 & Later) Switch- System On/Off Gas Heat Units DPST/5A Electric, HW or No Heat SPST/0A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Duct Hi Limit and Duct Static Pressure Sensors DHL Duct Hi Limit Switch SPS Pressure Transducer- Duct Sensor Code 3=,, SPS Pressure Transducer- Duct Sensor Code 3= Pressure Transducer- Space Sensor Code 3= 3, Not Shown on diagram. Quantity varies depending upon unit options selected. 3 For units built /7 contact Daikin Applied to ensure that the correct part(s) are identified. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 88

89 C F Section N- Main Control Box Control Panel- MicroTech III Components- (03/03 & Later), Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- Speedtrol inverter AFD R Relay- Condenser Fan R3 Relay- Condenser Fan R4 Relay- Condenser Fan R0 Relay- Heat R Relay- Gas Heat R4 Relay- Gas Heat Alarm R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4= R63 Relay- Duct Hi Limit Units with Return Fan Inverter 3PDT/0V Units with No Return Fan Inverter DPDT/0V R8 Relay- Inverter Reset 3 4P/6A/4V R8 Relay- Inverter Reset 3 4P/6A/4V R83 Relay- Smoke 3 4P/6A/4V R84 Relay- Smoke 3 4P/6A/4V R85 Relay- Smoke 3 4P/6A/4V R86 Relay- Smoke 3 4P/6A/4V R87 Relay- Smoke 3 4P/6A/4V R88 Relay- Smoke 3 4P/6A/4V Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Time Delays TD0 Time Delay, Return Air Fan Terminal Block TB Terminal Block Sensors ZNT Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground Block is p/n SCC Units only (Code = *F, *W). 3 Not Shown on diagram. 4 In late 03, Digital Room Sensor p/n was added as the preferred option. The other Zone Temperature Sensors are available as options. For positive p/n identification, refer to the drawings below. ZNT Sensor ZNT Sensor 3770 ZNT Sensor 3780 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 89

90 Section N- Main Control Box Power Panel Diagrams- (03/03 & Later) See Control Panel See Control Panel PL - PL43 Plugs The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 90

91 Section N- Main Control Box Power Panel Terminal Blocks, T Transformer & Fusing, Fuses, Plugs- (03/03 & Later) Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB,3,4,7 Terminal Block Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,W,Y Electric, Hydronic, No Heat Code 04= E,W,Y Electric, Hydronic, No Heat Code 04= E,W,Y Gas Heat Code 04= A Gas Heat Code 04= A Gas Heat Code 04= A Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Electric, Hydronic, No Heat Code 04= E,S,W,Y Electric, Hydronic, No Heat Code 04= E,S,W,Y Electric, Hydronic, No Heat Code 04= E,S,W,Y Gas Heat Code 04= A Gas Heat Code 04= A Gas Heat Code 04= A Gas Heat Code 04= A FC Fuse- T Transformer Gas Heat Code 04= A Electric, Hydronic, No Heat Code 04= E,S,W,Y Misc. Fuses / Circuit Breakers F,F3 Fuses- Control Circuit / Burner Motor Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor Code 04= A CB0 Circuit Breaker- Exhaust Fan (one motor) Code 4= Circuit Breaker- Exhaust Fan (two motors) Code 4= F0 Fuse- Exhaust Fan Fuse Block (one motor) Code 0=HE & Code 4= Fuse Cover (one motor) Code 0=HE & Code 4= /fuse /fuse /fuse Fuse (one motor) Code 0=HE & Code 4= Fuse (one motor) Code 0=HE & Code 4= Fuse (one motor) Code 0=HE & Code 4= Fuse Block (two motors) Code 0=HE & Code 4= Fuse Cover (two motors) Code 0=HE & Code 4= /fuse /fuse /fuse Fuse Block (two motors) Code 0=HE & Code 4= Fuse Cover (two motors) Code 0=HE & Code 4= /fuse Fuse (two motors) Code 0=HE & Code 4= Fuse (two motors) Code 0=HE & Code 4= PL- 43 Plugs Pin Plug varies varies varies varies 5 6 Pin Plug varies varies varies varies 6 Pin Plug varies varies varies varies 7 3 Pin Cap Kit varies varies varies varies 8 6 Pin Cap Kit varies varies varies varies 9 9 Pin Cap Kit varies varies varies varies 0 5 Pin Cap Kit varies varies varies varies Varies depending on unit options. Part number is for one individual section. Ground block is p/n When required TB, 3, 4 or 7 use Jumpers p/n ( pole), (3 pole), (4 pole), (5 pole). All T Transformers use Fuse Holder p/n & Terminal Cover p/n All possible Plugs used are listed. Check actual unit to verify which Plug is required. 4 Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 5 Used with Strain Relief (p/n ) & 6 pin Cap Kit (p/n ). Used for PL0, PL. 6 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 7 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 8 Used for PL9, PL0. 9 Used for PL8, PL9, PL35, PL36, PL43. 0 Used for PL7, PL8. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 9

92 Section N- Main Control Box Power Panel Fusing, Phase Protection, Power Blocks- (03/03 & Later), Continued Sch. Part Part Voltage Sym. Description Number 08V 30V Power Blocks PB Power Block- Main Code = P Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 40A Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat KW Electric Heat KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. Not Shown on diagram. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 9

93 Section N- Main Control Box Power Panel Receptacle, Disconnect Switch- (03/03 & Later), Continued Sch. Part Part Voltage Sym. Description Number 08V 30V Receptacle REC Receptacle Disconnect Switch DS Disconnect Switch- Main Switch- 00A Handle 9340 Shaft Switch- 50A Handle 9340 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Switch- 800A Handle Mechanism Shaft Lugs Switch- 000A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. This Shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This Shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. 5 Not Shown on diagram. Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 93

94 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Detail Diagrams- (03/03 & Later) Phase Barrier Front Mtd. Contact 3E MMP 3 Phase Barrier Front Mtd. Contact 3E MMP 3 MMP 3 Link 3B Contactor Link 3B 3A Spacer Contactor Front Mtd. Contact 3B Link Contactor MMP0 & M0 Link Detail 3, 5 HP Motors- 460/ 7.5 HP Motors- MMP0 & M0 Link Detail 3, 5 HP Motors- 08/30V 7.5 HP Motors- 08/30/ 0 HP Motors- All Voltages 5, 0 HP Motors- MMP0 & M0 Link Detail 5 HP Motors- 08/30/ 0, 40 HP Motors- 5, 30 HP Motor- 460/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier Front Mtd. Contact 3E MMP 3 3 Circuit Breaker (not shown) Link 3B Contactor Terminal Block 4A Contactor 4 Overload MMP0 & M0 Link Detail 0, 5, 30 HP Motors- 08/30V 40 HP Motors- 50 HP Motors- 460/ MMP0 & M0 Link Detail 40, 50 HP Motors- 08/30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 94

95 Section N- Main Control Box Power Panel Supply Fan Components- (03/03 & Later) 3 HP Motor- Code 3= HJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan A Contactor- Supply Fan 7A Aux. Contact- NC OR NO MMP0 MMP- Supply Fan 7-0A MMP- Supply Fan 3.5-5A A Spacer B Link Link E Phase Barrier N/S CB0 Circuit Breaker- Supply Fan 5A FB0 Fuseblock- Supply Fan Fuse- Supply Fan 5A Fuse- Supply Fan 0A Fuse- Supply Fan 7A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 95

96 Section N- Main Control Box Power Panel Supply Fan Components- (03/03 & Later), Continued 5 HP Motor- Code OR 3= JJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply OR Exhaust Fan 5A Contactor- Supply OR Exhaust Fan 6A Contactor- Supply OR Exhaust Fan 9A Contactor- Supply OR Exhaust Fan 7A Aux. Contact- NC OR NO MMP0 MMP- Supply OR Exhaust Fan - 6A MMP- Supply OR Exhaust Fan 5.5-8A A Spacer B Link Link E Phase Barrier N/S CB0 Circuit Breaker- Supply OR Exhaust Fan 5A FB0 Fuseblock- Supply OR Exhaust Fan Fuse- Supply OR Exhaust Fan 5A Fuse- Supply OR Exhaust Fan 0A Fuse- Supply OR Exhaust Fan 0A Fuse Cover/Puller- Supply OR Exhaust Fan N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V 7.5 HP Motor- Code 3= KJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 5A Contactor- Supply Fan A Contactor- Supply Fan 9A Aux. Contact- NC OR NO MMP0 MMP- Supply Fan 0-5A MMP- Supply Fan 7- A MMP- Supply Fan 9-.5A MMP- Supply Fan 7-0A A Spacer B Link Link E Phase Barrier N/S CB0 Circuit Breaker- Supply Fan 5A FB0 Fuseblock- Supply Fan Fuseblock- Supply Fan Fuse- Supply Fan 35A Fuse- Supply Fan 5A Fuse Cover- Supply Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 96

97 Section N- Main Control Box Power Panel Supply Fan Components- (03/03 & Later), Continued 0 HP Motor- Code 3= LJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 3A Contactor- Supply Fan 6A Contactor- Supply Fan A Aux. Contact- NC OR NO MMP0 MMP- Supply Fan 7-3A MMP- Supply Fan 3-8A MMP- Supply Fan - 6A MMP- Supply Fan 9-.5A A Spacer B Link E Phase Barrier N/S CB0 Circuit Breaker- Supply Fan 5A FB0 Fuseblock- Supply Fan Fuseblock- Supply Fan Fuse- Supply Fan 50A Fuse- Supply Fan 45A Fuse- Supply Fan 0A Fuse Cover- Supply Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. pc. PER Fuse 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 97

98 Section N- Main Control Box Power Panel Supply Fan Components- (03/03 & Later), Continued 5 HP Motor- Code 3= MJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 50A Contactor- Supply Fan 5A Contactor- Supply Fan 5A Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0 MMP- Supply Fan 36-45A MMP- Supply Fan 8-40A MMP- Supply Fan 4-0A MMP- Supply Fan - 6A A Spacer B Link Link E Phase Barrier N/S CB0 Circuit Breaker- Supply Fan 0A FB0 Fuseblock- Supply Fan Fuseblock- Supply Fan Fuseblock- Supply Fan Fuse- Supply Fan 70A Fuse- Supply Fan 60A Fuse- Supply Fan 30A Fuse Cover- Supply Fan Fuse Cover- Supply Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. pc. PER Fuse 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 98

99 Section N- Main Control Box Power Panel Supply Fan Components- (03/03 & Later), Continued 0 HP Motor- Code 3= NJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 65A Contactor- Supply Fan 3A Contactor- Supply Fan 5A Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0 MMP- Supply Fan 45-63A MMP- Supply Fan 3-8A MMP- Supply Fan 8-5A A Spacer B Link Link Link E Phase Barrier Phase Barrier N/S CB0 Circuit Breaker- Supply Fan 70A Circuit Breaker- Supply Fan 60A Circuit Breaker- Supply Fan 30A FB0 Fuseblock- Supply Fan Fuse- Supply Fan 40A Fuse Cover- Supply Fan N/S= Not Shown on Diagram. 08V 30V 5 HP Motor- Code 3= PJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 80A Contactor- Supply Fan 40A Contactor- Supply Fan 3A Aux. Contact- NC OR NO MMP0 MMP- Supply Fan 57-75A MMP- Supply Fan 45-63A MMP- Supply Fan - 3A B Link Link Link E Phase Barrier N/S CB0 Circuit Breaker- Supply Fan 90A Circuit Breaker- Supply Fan 80A Circuit Breaker- Supply Fan 40A FB0 Fuseblock- Supply Fan Fuse- Supply Fan 50A Fuse Cover- Supply Fan N/S= Not Shown on Diagram. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 99

100 Section N- Main Control Box Power Panel Supply Fan Components- (03/03 & Later), Continued 30 HP Motor- Code 3= QJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 95A Contactor- Supply Fan 80A Contactor- Supply Fan 40A Contactor- Supply Fan 3A Aux. Contact- NC OR NO MMP0 MMP- Supply Fan 70-90A MMP- Supply Fan 8-40A MMP- Supply Fan - 3A B Link Link Link E Phase Barrier N/S CB0 Circuit Breaker- Supply Fan 5A Circuit Breaker- Supply Fan 90A Circuit Breaker- Supply Fan 40A FB0 Fuseblock- Supply Fan Fuse- Supply Fan 60A Fuse Cover- Supply Fan N/S= Not Shown on Diagram. 08V 30V 40 HP Motor- Code 3= RJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 5A Contactor- Supply Fan 65A Contactor- Supply Fan 50A Aux. Contact- NC OR NO MMP0 Circuit Breaker- Supply Fan 50A MMP- Supply Fan 36-50A MMP- Supply Fan 8-40A B Link Link C Lugs- Supply Fan MMP0 (kit of 3pc.) E Phase Barrier OL0 Overload- Supply Fan 50-00A A Terminal Block- Supply Fan N/S CB0 Circuit Breaker- Supply Fan 50A Circuit Breaker- Supply Fan 5A Circuit Breaker- Supply Fan 60A Circuit Breaker- Supply Fan 50A N/S Lugs- Supply Fan CB0 (kit of 3pc.) N/S= Not Shown on Diagram. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 00

101 Section N- Main Control Box Power Panel Supply Fan Components- (03/03 & Later), Continued 50 HP Motor- Code 3= SJY Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 50A Contactor- Supply Fan 65A Aux. Contact- NC OR NO MMP0 Circuit Breaker- Supply Fan 50A MMP- Supply Fan 45-63A MMP- Supply Fan 36-50A B Link E Phase Barrier OL0 Overload- Supply Fan 50-00A A Terminal Block- Supply Fan N/S CB0 Circuit Breaker- Supply Fan 80A Circuit Breaker- Supply Fan 60A FB0 Fuseblock- Supply Fan Fuse- Supply Fan 5A Fuse- Supply Fan 75A The Circuit Breaker is wired to the Contactor assembly and is not shown in the reference drawing. 08V 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 0

102 Section N- Main Control Box Power Panel Compressor MMP- 4 and Contactor M- 4- (03/03 & Later) Unit Size 06E, 06E Phase Barrier 3E MMP 3 Front Mtd. Contact MMP 3 Front Mtd. Contact Link 3B Front Mtd. Contact A Contactor Front Mtd. Contact A 3B Link Contactor MMP- 4 & M- 4 Contactor Detail 08/30V MMP- 4 & M- 4 Contactor Detail 460/ 06, 06 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 40A A Front Mounted Contact- NO- NC Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compressor 45-63A Manual Motor Protector- Compressor - 3A Manual Motor Protector- Compressor 8-5A B Link Link E Phase Barrier /30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 0

103 Section N- Main Control Box Power Panel Compressor MMP- 6 and Contactor M- 6- (03/03 & Later) Unit Size 070E MMP 3 Phase Barrier 3E Front Mtd. Contact Front Mtd. Contact MMP 3 Link 3B Front Mtd. Contact A 3B Link Contactor Front Mtd. Contact A 3A Contactor Spacer MMP- 6 & M- 6 Contactor Detail 08/30V MMP- 4 & M- 4 Contactor Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 40A Contactor- Compressor 3A Contactor- Compressor 6A A Front Mounted Contact- NO- NC Front Mounted Contact- NO- NC Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compressor 8-40A Manual Motor Protector- Compressor 4-0A Manual Motor Protector- Compressor - 6A A Spacer B Link Link E Phase Barrier /30V 070 Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 03

104 Section N- Main Control Box Power Panel Compressor MMP- 6 and Contactor M- 6 - (03/03 & Later) Unit Size 075E Phase Barrier Front Mtd. Contact 3E MMP 3 Phase Barrier Front Mtd. Contact 3E MMP 3 Link Front Mtd. Contact 3B A Contactor Link Front Mtd. Contact 3B A 3A Spacer Contactor MMP- 6 & M- 6 Contactor Link Detail 08/30V MMP 3 MMP- 6 & M- 6 Contactor Link Detail Front Mtd. Contact Front Mtd. Contact A Contactor MMP- 6 & M- 6 Contactor Link Detail 3B Link Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor 3A Contactor- Compressor 5A A Front Mounted Contact- NO- NC Front Mounted Contact- NO- NC Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compressor 45-63A Manual Motor Protector- Compressor 7- A Manual Motor Protector- Compressor 4-0A A Spacer B Link Link Link E Phase Barrier Phase Barrier Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 04 08/30V 075

105 Section N- Main Control Box Power Panel Condenser Fan MMP- 4, Contactors M- 4, Fuses F, F Fantrol Units (Code 47= )- (03/03 & Later) MMP 3 Link 3B Contactor Ref. Schematic Part Part No. Symbol Description Number Cond. Fan Contactors M- 4 M- 4 Contactor- Cond. Fan Fan MMP s & Parts 3 MMP- 3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP- 3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP N/S Bus Bar N/S Bus Bar N/S Bus Bar Top Feed N/S= Not shown on diagram V 08 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 05

106 Section N- Main Control Box Power Panel Condenser Fan MMP- 4, Contactors M- 4, Fuses F, F Speedtrol Units (Code 47= )- (03/03 & Later) MMP & Contactors Detail MMP 3 Speedtrol Fuses Adapter 4 Puller Link 3B Contactor 3 Fuse Fuse Block Ref. Schematic Part Part No. Symbol Description Number Cond. Fan Contactors M- 4 M- 4 Contactor- Cond. Fan Fan MMP s & Parts 3 MMP- 3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP- 3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP Dinrail Adapter N/S Bus Bar N/S Bus Bar Top Feed Speedtrol Fusing 5 F, Fuse Block Fuse Cover/Puller F, Fuse N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information so that the required fuse(s) can be identified V 08 30V Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 06

107 Section N- Main Control Box Intelligent Equipment: Code 3= ****A Intelligent Equipment (IE) from Daikin Applied is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation. A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality. Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply. Click on this link to access the RPL for Intelligent Equipment: Maverick II Rooftop, MPS , Vintage E Rev. T /7 RPL / Page 07

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70003700 Revision U 07/2 Roofpak Applied Rooftop Units RPS, RDT, RFS, RCS Sizes 045-079 Tons Vintage D R40a To find your Daikin McQuay Parts distributor, call -800-377-2787 or

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W Replacement Parts List No. 70005300 Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT 045-074 Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor,

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017 Replacement Parts List No. 110502600 Revision I 09/2017 McQuay Superpak Applied Rooftop Units RRS, RSS 018-071 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019 Replacement Parts List No. 700052600 Revision G 0/209 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 Commercial 10 Ton Package Gas Unit DCG1202103BHXBAA DCG1202103BHXXAA DCG1202103BJXVAA DCG1202103BXXHAA DCG1202103BXXXAA DCG1202104BXXXAA DCG1202104BXXXAB DCG1202107BXXXAA REPAIR PARTS nufacturing Company,

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018 Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 Commercial 20 Ton Package Gas Units DCG2404003BAXAAA DCG2404003BXXXAA DCG2404004BXXXAA DCG2404004BXXXAB DCG2404007BXXXAA REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com

More information