Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Size: px
Start display at page:

Download "Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S"

Transcription

1 Replacement Parts List No Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 5 Nomenclature Electrical Legend Section A- Outdoor/Return Air Section Notes % Outside Air Damper with Hood- No Return Air Plenum % Outside Air Damper Detail w/ ACT3..., 0-30% Outside Air Section w/ ACT3... 3, % Economizer Section with Barometric Exhaust Damper- Units w/o Return Air Fans % Economizer Section with Barometric Exhaust Damper- Units w/ 44 Return Air Fans % Economizer Section with Prop Exhaust Fan & Damper % Economizer Damper Diagrams % Economizer Damper w/ ACT3 Components... 9 California Title 4 Assembly: Code 33 (Mid 0 & Later) = *F*** Return Air Plenum Isolation Damper w/ Actuator ACT Prop Exhaust Fan & Damper Detail... 3 Prop Exhaust Fan Inverter and Control Box... 33, 34 Design Flow Detail Return Air Fan Detail Return Air Fan Detail- Fan Mounts Return Air Fan Motors... 38, 39 Section Mounted Controls- OAE, RAE, LT, S, REC Section B- Draw-Thru Filter/Blank Section Notes... 4 Section Mounted Controls- PC5, LT3, S3, REC3, Magnehelic/Differential Pressure Gauges... 4 Filters... 4, 43 Air Blender Section C- Draw-Thru Blank Access Section or Separate Inverter Section Notes Section Mounted Controls- LT7, S7, REC Section D- Draw-Thru Cooling Section Notes Small Face DX Coils (Code 03= S) Large Face DX Evaporator Coils (Code 03= L) Section E- Spacer Section (RPS/RFS) OR Section E- Draw-Thru Heat Section (RDT) Notes Section Mounted Controls- LT8, REC8, S Hot Water OR Steam Coil Heat, Mixing Valves & Actuator VM Section F- Supply Air Section Notes Air Foil Fan- Double Width... 5 Air Foil Fan- Single Width- RDT (Draw-Thru/No Heat) Units... 5 Fan Mounts- 33 Airfoil Double Width Fan Fan Mounts- 36 Airfoil Double Width Fan Fan Mounts- 40 Airfoil Double Width Fan Fan Mounts- 44 AFSW- Draw-Thru/No Heat Units Fan Mounts- 49 AFSW- RDT Units Supply Air Fan Motors... 58, 59 Belt Guard Inverters & Inverter Bypass Control Box Motor HP , 6 Motor HP Motor HP Inverters Line Reactors Section Mounted Controls- PC7, HL, LT0, S0, REC0, UV Lights Section Mounted Controls- MAT, EFT, SAT, DAT, OAT, SD Section Mounted Controls- SCB- TB5, TB7, TB8, PB0, PB9, PB0, PB Section G- Blow-Thru Heat Section Notes Section Mounted Controls- LT, S, REC Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

3 Contents Continued Section G- Blow-Thru Heat Section, Continued Option : Blank Compartment Diffusers Option : Hot Water OR Steam Coil Heat Mixing Valves & Actuator VM... 8 Option 3: Electric Heat Heaters, Hi Limit Cutouts, Diffusers... 8, 83 Electric Heat Control Box- 03/3 & Earlier Electric Heat Control Box- 04/3 & Later Option 4- Gas Heat Code 04= A Vestibules, Heat Exchangers and Primary Components- 500, 640, 650, 790, 800, 000, 00, 400MBH Vestibules, Heat Exchangers and Primary Components- 500, 000MBH Modulating Burner Hi Turn Down Burner Modulating Burner Controls MicroTech II OR No Controls Diagram MicroTech II OR No Controls Components MicroTech III Controls Hi Turn Down Burner Controls MicroTech II OR No Controls Diagram MicroTech II OR No Controls Components MicroTech III Controls Gas Train- Inlet Gas Train- Controls: GV, GV, GV4, GV5, GV6, GV7, GV8, GV9, VM Gas Train- Outlet... 7 Gas Train- Damper Linkage... 8 Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting... 9, 0 Section H- Blow-Thru Heat Blank Access Section OR Sound Attenuator Notes... Sound Attenuator... Section Mounted Controls- LT9, REC9, S9... Section I- Blow-Thru Cooling Section Notes... Access Door Latching Assemblies, Key, & Lock (All Sections)... Section J- Final Filter Section Notes... 3 Section Mounted Controls- HL3, PC Filters... 4, 5 Section K- Discharge Plenum Section- RPS, RFS Notes... 6 Section Mounted Control- OAT, DAT, SD... 6 Damper Assembly- w/ Actuator ACT Section L- Out-of-Airstream Blank Access Section Notes... 8 Section Mounted Controls- LT0, REC0, S Section M- Condenser Section Notes... 9 Condenser Fan Deck Assembly- 080 thru 05D Condenser Fan Deck Assembly- 0 thru 40D... 33, 34 Quiet Fan Assembly Compressors & Compressor Components Unit Size 080 thru 09D Unit Size 00, Unit Size 05, Unit Size 0D... 39, 40 Unit Size 5, 30D... 4 Unit Size 40D... 4 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

4 Contents Continued Section M- Condenser Section, Continued RCS Pressure Manifolds- PC3, PC3, HP, HP, LP, LP, SPTRL RPS/RDT Pressure Controls Box- AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC , 45 MicroTech II OR No Controls- RCS Control Box MicroTech III- RCS Control Box Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C Section N- Main Control Box Notes Control Box Component Label Diagram Control Panel MicroTech II Units with Controller: Code = *D, *S OR No Controls: Code = YM, YC Control Panel (03/3 & Earlier) MicroTech III Units with Controller: Code = *E, *F, *W Control Panel (04/3 & Later) MicroTech III Units with Controller: Code = *E, *F, *W Power Panel (03/3 & Earlier) Power Panel Diagrams Terminal Blocks, T Transformer & Fusing Fusing continued, Phase Protection, Ground Fault, Power Blocks Power Blocks continued, Receptacle, Power Supply, Disconnect Switch DS Disconnect Switch DS continued Disconnect Switch DS, Circuit Breakers CB0, Circuit Breakers CB0, 0 continued, Plugs... 7 Supply MMP0 & M0 Fan Contactor and Return MMP0 & M0 Fan Contactor Compressor MMP- 6 and Contactor M- 6 Unit Size 080, 08D Unit Size 085 thru 09D Unit Size 00, 0D... 8 Unit Size 05, 0D... 8 Unit Size 0D Unit Size 5, 30D Unit Size 40D Condenser Fan Contactors, MMPs, & Fusing Power Panel (04/3 & Later) Power Panel Diagram... 9 Terminal Blocks, T Transformer & Fusing Fusing continued, Phase Protection, Ground Fault, Power Blocks Power Blocks continued, Receptacle, Plugs Disconnect Switch DS, Supply MMP0 & M0 Fan Contactor, Return MMP0 & M0 Fan Contactor Diagrams Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components Compressor Motor Protector MMP- 6, & Contactor M- 6 Unit Size 080, 08D Unit Size 085 thru 09D Unit Size 00, 0D... 07, 08 Unit Size 05, 0D Unit Size 0D... 0, Unit Size 5, 30D... Unit Size 40D... 3, 4 Condenser Fan Contactors, MMPs, & Fusing Intelligent Design... 9 Section O- Refrigeration Tubing Notes... 0 Refrigeration Tubing Diagrams... 0, Valves, Filter Driers, Sight Glasses, Hot Gas Bypass & Liquid Line Kits..., 3 Hot Gas Reheat... 4 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

5 Parts List Revision History Revision Date Description A- AM 06/7 Archived Revisions A- AM. AN 07/7 Cover: Added S to Unit Model Code. (A few early units were released w/ obsolete Code 44= S.) Various: Deleted info. regarding 09D units. These are Standalone RCS units only. Page 7-3: Misc. updates & corrections. Page 9, 4, 44, 45, 50, 9, 54, 9: Rewrote Notes. Page, 4, 9: Added footnote re. actuator change. Page 7: Updated dwg. Rewrote pg. header. Changed bub. Ref # 6 Fan Assy. to Ref # 40 per BOM. Added Grd. Fan Assys. Page 36, 37: Reversed pg. order & updated the TOC. Updated dwgs. & tables. Page 40: Rewrote footnote #. Page 43: Rewrote Blender table header. Page 74: Rewrote footnote #. Page 77: Changed Lamp to Bulb or Fixture. Page 8: Added Freezestat FS p/n Page 94: Updated table, dwg; & rewrote footnotes. Page 95: Added Turbulator to table & rewrote footnotes. Page 06, 09: Updated Ref. #34 TB p/ns & qtys. Page 0-, 7: Updated gas vlv. p/ns. Page 4: Changed Ref. # 49 VM from to Page : Updated Door Latching Assy. table. Page 3: Corrected Section Mounted Controls coding in section header. Page 30, 33: Updated dwgs. Page 3, 3, 34: Misc. p/n updates/corrections. Page 35: Added Blank Panel Ref. # 55 to table. Page 48, 60: Updated TD, description & p/n. Rewrote footnotes. Page 49, 5: Deleted T information. (T only used on RCS units when Code = *A.) Page 5: Deleted pg. Repaginated the form & updated the TOC. Page 63, 66 (OLD) 6, 65 (NEW): Updated R63 p/ns. Page 65 (OLD) 64 (NEW): Corrected SPS, p/n from to Added MTIII Remote Keypad, Remote Interface & Transducer Snubber p/ns. Page 68 (OLD): Deleted pg. Repaginated the form & updated the TOC. Page 86, 87: Updated/corrected p/ns. Page 88-9 (NEW): Added pgs. for additional Cond. Fan p/ns. Repaginated the form & updated the TOC. Page 9 (OLD) 93 (NEW): Deleted pg. Repaginated the form & updated the TOC. Page 8 OLD 9 (NEW): Rewrote Notes & pg. header. Updated the dwg. Page 0, (OLD), (NEW): Misc. updates. Rewrote footnotes & footnote notation. Page (OLD) 3 (NEW): Updated dwg. Deleted footnote #. AO 08/7 Page 6, 64: Added RHB, p/n from pg. 3. Page, : Added Check Vlv. p/n. Page 3: Added Ref # 00 E-Coated coil. Moved interface board p/n to pgs. 6, 64. AP 09/7 Page 7: Rewrote PB4, 4 descriptions. Page 9, 54: Rewrote Notes. Page 46, 47: Changed bub. PB4 to PB4/4 Page 48: Added /7 & Later PVM components. Page 49: Updated PB4, 4 p/ns & deleted NA PB4 info. Page 5: Added /7 & Later PVM components. Updated PB4 p/ns. Page 68: Corrected PVM qty. Page 94: Added /7 & Later PVM and components. Added footnote # 4. AQ 0/8 Page 40-4: Added 4/4 & Later CC Heater Ref # 45 p/n. Page 6, 64: Deleted OBS Display. Combined with Remote Keypad AR 05/8 Page 7: Rewrote footnote #. Page 9, : Misc. updates. Page 78: Corrected misc. formatting issues. Page 9, 0: Rewrote Notes. Page 68, 94: Corrected Code 7 coding. Page 9: Rewrote Notes & updated the dwg. Page (NEW): Added pg. for new Refrigeration dwgs. Repaginated the form & updated the TOC. Page, (OLD), 3 (NEW): Updated/corrected table & rewrote footnotes. Updated the TOC. Page 3 (OLD) 4 (NEW): Added dwgs. Updated table. Rewrote pg. header. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

6 Nomenclature Unit Model and Serial Number Unit Model Number R PS 080 D S A R = RoofPak Unit Configuration PS = Heating, Mechanical Cooling; Single Zone Unit FS = Heating, Future Mechanical Cooling; Single Zone Unit CS = Condensing Section Only; Single Zone Unit DT = Draw Through Heating, Mechanical Cooling Nominal Capacity (tons) Design Vintage Cooling Coil Size S = Standard (Low Airflow) L = Large (High Airflow) Heat Medium A = Natural Gas E = Electric S = Steam W = Hot Water Y = None (Cooling Only) Serial Number FBO U Plant Identification FBO = Faribault, MN U = Unit Year of Manufacture 08= = 009 0= 00 etc. Serial Number (build sequence) Month of Manufacture 0= January 0= February 03= March 04= April 05= May 06= June 07= July 08= August 09= September 0= October = November = December Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

7 Nomenclature Unit Code Index RPS 080D S W Y EY D 7 AL P LE S 3 CC S0 BY AE 44B KEY Code C Y AB Y CYYS 4Z083D YYYYYY YYYYYY 30A LEY 50A WE3E CYYS 4Z083D YYYYYY Y Y BY Y 6 MS R Y D YYAA General Options Unit Model Codes that Pertain: 03, 05, 06, 07, , 5, 33, 6-66 (Mid 0 & Later) Auxiliary Controls/Remote Sensors Unit Model Codes that Pertain:, 3, 6, 7, 8 Section A Return/Outside Air Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier), 58 (Mid 0 & Later) Sections B, C, D, E DrawThru Cooling Sections Section B- Filter Section 9, 0,,, 3 (Mid 0 & Earlier), 58 (Mid 0 & Later) Section C- DrawThru Blank Access Unit Model Codes that Pertain: 6, 4, 5 Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 03, 7, 8 Section E- Spacer Section (RPS, RFS) Unit Model Codes that Pertain: 30 Section E- DrawThru Heating Section (RDT) Unit Model Codes that Pertain: 04, 30 Section F- Supply Fan Options Unit Model Codes that Pertain: 3, 3, 33, 59 (Mid 0 & Later), 08, 4, 5, 40, 49 Sections G, H, I BlowThru Options Section G= BlowThru Heat/Blank Unit Model Codes that Pertain: 04, 34 Section H= BlowThru Blank Access Unit Model Codes that Pertain: 38, 34 Section I- BlowThru Cooling Sections Unit Model Codes that Pertain: 03, 35, 36 Section J- Final Filter Section Unit Model Codes that Pertain: 39 Section K- Discharge Plenum Section Unit Model Codes that Pertain: 40 Section L- Blank Compartment Section- Out of Airstream Unit Model Codes that Pertain: 4 Section M- Condenser Section Unit Model Codes that Pertain: 09, 43, 47 Section N- Main Control Panel Unit Model Codes that Pertain: 04, 08, 09,,, 4, 5, 7, 8, 3 & 68 Section O- Refrigeration Tubing Unit Model Codes that Pertain: 03, 45, 46, 48, 54 (Mid 0 & Later) An "X" located in ANY position in a code string (ESPECIALLY Code 50 for units built mid 0 & earlier OR Code 60 for units built 0 & Later) indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). In mid 0 the code structure was changed from a 54 code index to a longer more detailed format. A sample 54 Code version is shown above. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

8 Nomenclature Unit Code Index, Continued Code 03= Cooling Coil S= Small L= Large Y= None Code 04= Heat Section- Type of Heat Y= No Heat S= Steam Heat A= Natural Gas Heat E= Electric Heat W= Hot Water Heat Code 05= Split Unit C= Unit/Condenser F= Fan/Heat Y= None Code 06= Insulation and Liners =, 3/4# with liners on doors = ½, ½# with solid liners on doors & ceilings 3= ½, ½# with perforated liners in plenums, solid elsewhere 4= ½, ½# with solid liners on doors, ceilings and floors 5= ½, ½# with perforated liners in plenums, solid elsewhere (including floors) 6= ½, ½# with SS Solid Liners on doors, ceilings and floors Code 07= Approval Agency Listing CC, CD, CY= ETL Canada EM, EU, EY, YU= ETL/MEA USA YY= None Code 08= Main Control Box Location D= Discharge Plenum (RPS, RFS), Standard (RCS) F= Supply Fan Section (RDT) Code 09= Unit Voltage = 08/60/3 7= 460/60/3 9= 30/60/3 37= 575/60/3 Code 0= Starting Option AL= Across-the-Line Code = Field Power Connection and Disconnect D= Three Disc.: EH/SAF&RAF&CB/Balance of Unit P= Single Power Block: Complete Unit Q= Two Power Blocks: EH/Balance of Unit R= Two Power Blocks: Fans & Controls/Balance of Unit A= One, thru-the-door Disconnect: Complete Unit C= Two, thru-the-door Disconnects: SAF&RAF&CB/Balance of Unit B= Two, thru-the-door Disconnects: EHB/Balance of Unit D= Three thru-the-door Disc.: EH/SAF&RAF&CB/Balance of Unit Code = Temperature Controls MicroTech II Digit : Communication Type L= LonMark B= BACNet w/mstp E= BACNet w/ethernet S= Standalone (no communication) Digit : Control Type D= Discharge Air S= Space or Zone Control MicroTech III Digit : Communication Type L= LonWorks B= BACNet w/mstp E= BACNet w/ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit : Control Type E= Discharge Air w/ Static Pressure Control F= Space or Zone Ctl. W= Discharge Air w/ Space Control No Controls YM= No Temperature Controls w/floating point control YC= No Temp. Ctls. w/6-9 volt DC modulating gas heat Actuator YA, A, A= RCS Standalone unit codes (see RPL form ) Code 3= Air Flow Controls Y= None = Duct Sensor = Duct Sensors 3= Duct and Space Sensor 4= Space Sensor 5= Duct Hi Limit (DHL) Sensor Code 4= Inverters Y= None Separate Section = SA Fan only w/ Bypass = SA & RA Fans w/ Bypass 4= RA only w/ Bypass No Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan w/o Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan w/o Bypass Code 5= Inverter Brand Y= None A= ABB Inverter G= Graham Inverter Q= Schneider Inverter R= Reliance Inverter S, B= Daikin Applied Inverter F= Field Installed Inverter controlled by MicroTech controller Code 6= Smoke Detectors Y= None = Return Air Fan Section = Supply Air Fan Section 3= (RAF) + (SAF) Code 7= Misc. Aux. Controls C G Y= None F= Freezestat (Steam or HW Heat only) P= Phase Failure G= Ground Fault Protection L= Line Reactors (Inverter w/ separate section only) A= Freezestat & Phase Failure (Steam or HW Heat only) B= Freezestat & Ground Fault (Steam or HW Heat only) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam or HW Heat only) E= Freezestat & Line Reactors (Steam or HW Heat & Inverter w/ separate section only) H= Phase Failure & LIne Reactors (Inverter w/ separate section only) J= Freezestat, P.F. & Line Reactors (ST or HW Heat & Inverter w/ separate section only) K= Ground Fault, Phase Failure & Line Reactors (Inverter w/ separate section only) = UV Lights = UV Lights & Freezestat (Steam or HW Heat only) 3= UV Lights & Phase Failure 4= UV Lights & Line Reactors (Inverter w/ separate section only) 5= UV Lights, Freezestat & Phase Failure (Steam or HW Heat only) 6= UV Lights, Freezestat & Line Reactors (ST or HW Heat & Inv. w/ sep. section only) 7= UV Lights, Phase Failure & Line Reactors (Inverter w/ separate section only) 8= UV Lights, Freezestat, Phase Failure & Line Reactors (ST or HW Heat & Inv. w/ separate section only) C= Differential Enthalpy Y= None (includes mechanical enthalpy) Code 8= Misc. Controls/ Unit Length A, S, Y = None ( = Air Handler Length [in.]) M, W = Modem ( = Air Handler Length [in.]) K, R = Remote Keypad ( = Air Handler Length [in.]) U = Unit Powered Receptacle ( = Air Handler Length [in.]) V = K + U ( = Air Handler Length [in.]) Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

9 Nomenclature Unit Code Index, Continued Code 9= Return Air Plenum YY= No section BY= Bottom Return BB= Bottom Return w/burglar Bars BE= Bottom Return w/isolation Damper HY= Back Return LY= Left Return SY= Side Return Code 0= Outdoor Air Options YY= None AE= 00% Outside air damper w/ Hood & Actuator AY= 00% Outside air damper w/ Hood/no Actuator BE= 0-30% Outdoor air section w/ Actuator BY= 0-30% Outdoor air section w/o Actuator DE= 0-00% Econ. w/barometric Exhaust Damper w/ Act. DY= 0-00% Econ. w/barometric Exhaust Damper w/o Act. EE= 0-00% Econ. w/power closure Exhaust Damper w/ Act. EY= 0-00% Econ. w/power closure Exhaust Damper w/o act. HE= 0-00% Econ. w/prop Exhaust Damper w/ Act. HY= 0-00% Econ. w/prop Exhaust Damper w/o Act. FE= same as DE + Design Flow FY= same as DY + Design Flow GE= same as EE + Design Flow GY= same as EY + Design Flow JE= same as HE + Design Flow JY= same as HY + Design Flow KE= same as DE + Ebtron Sensor KY= same as DY + Ebtron Sensor LE= same as EE + Ebtron Sensor LY= same as EY + Ebtron Sensor ME= same as HE + Ebtron Sensor MY= same as HY + Ebtron Sensor Code = Return Air Fan YYYY= No Return Air Fan 44B()= 44 Airfoil Single Width ()= Isolator type: = Rubber-in-Shear (RIS) = Spring 3= Spring w/ seismic restraints Code = Return Air Fan Motor YYY= No Return Fan J K Y Y= None S= Shaft Grounding Kit E= High Eff. ODP motor H= High Eff. Totally-Enclosed J= Premium Eff. ODP K= Premium Eff. Totally-Enclosed J= 5.0 HP P= 5.0 HP K= 7.5 HP Q= 30.0 HP L= 0.0 HP R= 40.0 HP M= 5.0 HP S= 50.0 HP N= 0.0 HP T= 60.0 HP (prop exhaust option is always J [5.0 HP]) Code 3= Return Air Fan Drive Selection (Mid 0 & Earlier RPS, RFS, RDT ALL) YYYY= No Return Air Fan A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 3= Miscellaneous Electrical Options (Mid 0 & Later RPS, RFS, RCS ALL) Digit : UV Lights Y= None U= UV Lights Digit : Plenum/Vestibule Lights Y= None P= Plenum Lights V= Vestibule Lights B= Plenum & Vestibule Lights Digit 3: SpeedTrol, Energy Recovery, HGRH Inverter Y= None A= ABB B= Daikin Applied Q= Schneider Digit 4: 5V Service Outlet Y= Field Supplied 5V Power, Outlet by Factory F= Factory supplied Line Voltage & Outlet Digit 5: Intelligent Equipment Y= None A= Intelligent Equipment (IE) L= ie Express Code 4= Exhaust Fans or Frost Protection Y= None = Prop Exhaust Fans w/ Hood 3= 3 Prop Exhaust Fans w/ Hood Code 5= DrawThru Filter Section Digit : Section Type A= Angular (4 Section) D= Angular with low CFM Blender- 48/4 section E= Angular with high CFM Blender- 48/4 section F= Flat (4 Section) G= Flat with low CFM Blender- 48/4 section (RPS, RFS Mid 0 & Earlier, RDT ALL) G= 4 Angular- 4 section (RPS, RFS Mid 0 & Later) H= Flat with high CFM Blender- 48/4 section L= Large Staggered- 48/4 section S= Staggered- 48 section T= Staggered with low CFM Blender- 48/48 section V= Staggered with high CFM Blender- 48/48 section B, D= Blank 4 section C, E= Blank 48 section Digit : Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/intersept H= Cartridge 85% Efficient w/ Intersept (RPS, RFS Mid 0 & Earlier, RDT ALL) H= Throwaway 85% Efficient (RPS, RFS Mid 0 & Later) D= Cartridge 65% Efficient E= Cartridge 95% Efficient G= Cartridge 65% Efficient w/intersept Code 6= Blank DrawThru Section Y= No section E= Blank 4 Section F, S= Blank 48 Section Code 7= DrawThru Drain Pan/Cooling Coil Section YYYY= No section Digits - 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only (48 section) GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY only) Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

10 Nomenclature Unit Code Index, Continued Code 8= DrawThru Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D D= Lanced Aluminum 3= 3 Row 4= 4 Row 5= 5 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 9= DrawThru Heating Coil YYYYYY= No Heating Coil Code 30= DrawThru Heating Section (RDT) or Blank Spacer Section (RPS, RFS) YYYYYY= No Heating Section EEEEEE= Blank 4 Section BBBBBB, FFFFFF= Blank 48 Section Hydronic Heat W J 3 E E= Electric Actuator Y= Less Actuator = Way Steam Valve 3= 3 Way HW Valve Y= No Valve F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. Y= No Valve Pkg. S= 5JA060H (6FPI, Row 5J Steam Coil) S= 5JA0H (FPI, Row 5J Steam Coil) S3= 5JA060C (6FPI, Row 5J Steam Coil) S4= 5JA0C (FPI, Row 5J Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5 WS HW Coil) Code 3= Supply Air Fan 33A()= 33 Airfoil Double Width (RPS, RFS) 36A()= 36 Airfoil Double Width (RPS, RFS) 40A()= 40 Airfoil Double Width (RPS, RFS) 44B()= 44 Airfoil Single Width (RDT) 49B()= 49 Airfoil Single Width (RDT) ()= Fan Isolators: = Rubber-in-Shear (RIS) = Spring 3= Spring w/ seismic restraints Code 3= Supply Air Fan Motor K E Y Y= None S= Shaft Grounding Kit E= High Eff. ODP Motor H= High Eff. Totally-Enclosed J= Premium Eff. ODP Motor K= Premium Eff. Totally-Enclosed H= 3.0 HP M= 5.0 HP R= 40.0 HP J= 5.0 HP N= 0.0 HP S= 50.0 HP K= 7.5 HP P= 5.0 HP T= 60.0 HP L= 0.0 HP Q= 30.0 HP U= 75.0 HP Code 33= Supply Air Fan Drive Selection (Mid 0 & Earlier RPS, RFS, RCS, RDT ALL) A Service Factor/Pitch Type Required RPM A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 33= Miscellaneous Mechanical Options (Mid 0 & Later) Digit : Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DrawThru & Blow- Thru sections Digit : California Title 4 Y= None F= Economizer w/ Fault Detection/Diagnosis (FDD) Digit 3: Ebtron Air Flow Options S= Ebtron Hybrid G= Ebtron Gold Digit 4: Heating Coil Options Y= None E= Electrofin Coating Digit 5: Cooling Coil Options Y= None E= Electrofin Coating Code 34= BlowThru Heat Section (RPS, RFS) YYYYYY= No section, cooling only BBBBBB= Blank 48 section, no heat, cooling only Gas Heat 079 S S C Hydronic Heat W J 3 E A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position E= Modulating Burner/Maximum gas pressure= 0.5 psi R= Modulating Burner/with H.P. Regulator Range= - 3 psi H= Hi Turn Down Burner 0: T= Hi Turn Down Burner 0:/with H.P. Regulator Range= - 3 psi U= Hi Turn Down Burner 0:/with H.P. Regulator Range= 5-0 psi S= Stainless Steel Heat Exchanger MBH (in 0 s) ex. 065= 650 MBH [050,064,065,079,080,00,0,40,50,00] E= Electric Actuator Y= Less Actuator = Way Steam Valve 3= 3 Way HW Valve Y= No Valve F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. Y= No Valve Pkg. S= 5JA060H (6FPI, Row 5J Steam Coil) S= 5JA0H (FPI, Row 5J Steam Coil) S3= 5JA060C (6FPI, Row 5J Steam Coil) S4= 5JA0C (FPI, Row 5J Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5WS HW Coil) Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

11 Nomenclature Unit Code Index, Continued Code 34= BlowThru Heat Section (RPS, RFS), Continued Electric Heat E00 Y Always Y = Stage = Stages 4= 4 Stages 6= 6 Stages E00= 0 KW Heater E60= 60 KW Heater E040= 40 KW Heater E00= 00 KW Heater E060= 60 KW Heater E40= 40 KW Heater E080= 80 KW Heater E80= 80 KW Heater E00= 00 KW Heater E30= 30 KW Heater E0= 0 KW Heater Code 35= BlowThru Drain Pan/Cooling/Heating Coil Section YYYY= No section Digits - 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only- 48 section GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY) Code 36= BlowThru Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D D= Lanced Aluminum 3= 3 Row 4= 4 Row 5= 5 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 37= N/A to RPS/RDT/RFS/RCS- Always YYYYYY Code 38= BlowThru Blank Access Section (Mid 0 & Earlier) Y= No section B= Blank Section after Heat Section- 48 section Code 38= Attenuator Section (Mid 0 & Later) Y= No section G= With 36 Std. Straight Attenuator K= With 36 Std. Straight Attenuator w/ Tedlar Coating H= With 60 Std. Straight Attenuator L= With 60 Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating F= Blank 48 Section E= Blank 4 Section Code 39= Final Filter Section Y= No section A= Flat filter section, 95% cartridge, 4/4 section J= Flat filter section, 95% cartridge, 4 section B= Staggered filter section, 95% cartridge, 4/48 section K= Staggered filter section, 95% cartridge, 48 section E= Flat filter section, 95% cartridge w/ Intersept, 4/4 section L= Flat filter section, 95% cartridge w/ Intersept, 4 section F= Staggered filter section, 95% cartridge w/ Intersept, 4/48 section M= Staggered filter section, 95% cartridge w/ Intersept, 48 section W= Large Staggered filter section, 95% cartridge, 48/4 section G= Flat filter section, 95% HEPA cartridge, 4/48 section N= Flat filter section, 95% HEPA cartridge, 48 section H= Flat filter section, 95% cartridge, 48/48 section C, Q= Blank- 4/4 section D, R= Blank- 4/48 section S= Blank- 4 section T= Blank- 48 section Code 40= Discharge Plenum BY= Bottom Discharge BB= Bottom Discharge w/ Burglar Bars BE= Bottom Discharge w/ Discharge Damper (VAV) FY= Front Discharge (RFS) GY= Bottom Discharge (RDT) GB= Bottom Discharge w/ Burglar Bars (RDT) HY, LY= Left Side Opposite Side RY= Right Side Drive Side HY = LH Side Discharge Code 4= Blank Compartment Section- Out of Airstream Y= No section = 48/4 Blank Section only- out of airstream with light = 48 Blank Section only- out of airstream with light Code 4= Compressor Capacity Control 6= 6 steps Code 43= Condenser Options Digit Air Coil M= 5mm Micro Channel Coil P= 5mm Electrofin Coated Micro Channel Coil T= 3mm Micro Channel Coil U= mm Electrofin Coated Micro Channel Coil Y= None Digit Condenser Options G= Coil Guards, Steel S= Seal Tite Conduits B= G + S Y= None Code 44= Compressor Type R, S= Scroll R40A Code 45= Compressor Isolation = Resilient rubber-in-shear Code 46= Piping Options = Hot Gas Bypass, circuit # only 4= + 3 = Hot Gas Bypass, circuits & 5= + 3 3= Replaceable Filter Drier Core Y= None Code 47= Low Ambient Operation = FanTrol 3= Quiet Fan + FanTrol = SpeedTrol 4= Quiet Fan + SpeedTrol Code 48= IBC Seismic Construction H= Modulating Hot Gas Reheat I= Seismic Construction (Code and/or Code 3 must be ***3) K= Modulating Hot Gas Reheat and Seismic Construction J= IBC Seismic Construction- Category E/F A= ASCE 7-0 Wind Certification w/ Seismic Construction Y= None Code 49= Supply and Return Fan Options Y= None A= SA Fan Belt Guard B= SA Fan Section Light C= A + B D= SA & RA Fan Belt Guard E= SA & RA Fan Section Light F= D + E Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

12 Nomenclature Unit Code Index, Continued Code 50= Miscellaneous (Mid 0 & Earlier) YY= None XX= Special Code 50= Blender Section (Mid 0 & Later) Y= None L= Low CFM Blender (48 section) H= High CFM Blender (48 section) E= Blank 4 Section F= Blank 48 Section Code 5= Packaging (Mid 0 & Earlier) = Steel Skid = Consolidated Ship Code 5= Draw=Thru Pre-Heat Section (Mid 0 & Later) YYYYY= None EEEEEE= Blank 4 Section FFFFFF= Blank 48 Section W E 3 E Y= No Actuator E= Electric Actuator Y= No Valve = - Way Valve (ST) 3= 3- Way Valve (HW) Y= No Valve E=.5 Valve F=.50 Valve G=.00 Valve J= 3.00 Valve = 9 FPI Row (HW) OR 6 FPI Row (ST) = FPI Row (ST) 3= 06 FPI Row (ST) 4= FPI Row (ST) = 9 FPI Row (HW) W= Hot Water Heat (HW) S= Steam Heat (ST) Code 5= Parts Warranty (Mid 0 & Earlier) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 5= Drain Pan/Humidifier Section (Mid 0 & Later) YY= None DH= Humidifier w/ stainless steel Drain Pan 48 section DY= Stainless steel Drain Pan only, 48 section EE= Blank 4 Section FF= Blank 48 Section Code 53= Compressor Warranty (Mid 0 & Earlier) Y= None (RFS) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special Code 53= Custom Specifications (Mid 0 & Later) YY= None RR= B vintage replacement unit Code 54= Heat Exchanger Warranty (Mid 0 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 54= Hot Gas/Liquid Subcool Reheat (Mid 0 & Later) YY= None BM= BlowThru Modulating Hot Gas Cir. # (includes SpeedTrol) ML= Modulating Liquid Subcool Reheat Circuits # & (includes SpeedTrol) BL= BlowThru Modulating, Hot Gas Circuit #, AND Modulating Liquid Subcool Reheat Circuits # & (includes SpeedTrol) Code 55= Ultra High Efficiency Units YY= None HE= Ultra High Efficiency Unit (08D, 09D, 0D) Code 56= Chicago Code/Refrigeration Service Valves YY= None CC= Chicago Code YV= Refrigeration Service Valves CV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS/RDT/RFS/RCS- Always YY Code 58= Return Air Fan Drive Selection A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 59= Supply Air Fan Drive Selection A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 60= Miscellaneous Specials YY= None XX= Special Code 6= Packaging/ASHRAE Certification = Steel Skid = Consolidated Ship 3= Steel Skid w/ ASHRAE Certification 4= Consolidated Ship w/ ASHRAE Certification Code 6= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 63= Compressor Warranty Y= None (RFS) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special Code 64= Heat Exchanger Warranty Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 65= Unit Family 077C= D Code 66= Drain Connection Y= None L= Left Side R= Right Side (drive side) Code 67= ASHRAE Certification Y= None B= AHRI Certified C= AHRI Certified D= AHRI Certified Code 68= Short Circuit Current Rating YY= None 0= 0 SCCR = SCCR 65= 65 SCCR Code 69-7 N/A to RPS/RDT/RFS/RCS- Always YYYYYYYY Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

13 Nomenclature Unit Section Layout Examples A= Return Air/Outside Air/ Heat Recovery/Prop Exhaust Section B, C, D, E= DrawThru Section F= Supply Fan Section A B C D F G H J K L M G, H, I= BlowThru Section RPS J= Final Filter K= Discharge Plenum L= Out-of Air- Stream Blank Access M= Condenser Section A B C D F G H J K M Prop Exhaust DrawThru Return Air Fan DrawThru A B C D F G H J K M A B C F G H I J K M Heat Recovery DrawThru Heat Recovery BlowThru RFS A B C D F G H J K RCS M Return Air Fan DrawThru RDT A B C D E F M A B C D E F M With Prop Exhaust With Return Air Fan The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

14 Nomenclature Control Locations RPS, RFS, RCS Supply Air Section RDT Prop Exhaust (not shown) Condenser Section Inverters, Line Reactors & Manual Bypass Electric Heat Control Panel N Main Control Panel Fantrol/ Speedtrol Box Controls Locations Condenser Control Panel (RCS Only) Condenser Control Panel (RCS Only) The Unit Section Layout Diagrams shown above are to be used only for reference. Sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

15 Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Dampers Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT 0, Actuator Motors, Exhaust Dampers Return Air Section AFD/VFD0 Inverter, Supply Fan AFD or Supply Fan Sect. AFD/VFD Inverter, SpeedTrol Motor Condenser Section AFD/VFD0 Inverter, Return Fan AFD or Supply Fan Sect. AFD/VFD Inverter, SpeedTrol Motor Condenser Section AS Blower Air Switch Furnace Section BM Burner Blower Motor Furnace Section C0 Power Factor Capacitors, Supply Fan Supply Air Section C0 Power Factor Capacitors, Return Fan Return Air Fan CB0 Circuit Breaker, Supply Fan Main Control Box CB0 Circuit Breaker, Return Fan Main Control Box CCB, Compressor Control Boards (MicroTech II) Main or Cond. Ctl. Box COMPR.- 6 Compressors Condenser Section CS, Control Switches, Refrigerant Circuits Condenser Control Box DAT Discharge Air Temperature Sensor Discharge section DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS Disconnect, Total Unit or Condenser/Heat Main Control Box DS Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS4 Disconnect, Condenser Cond. Control Box DS6 Disconnect- Unit Supplied Line Voltage Condenser Section EFT Entering Air Temperature Sensor Supply Fan Section EHB Staged Electric Heat Board Main Control Box ECB Ebtron Sensor Return Air Section EXPA, B, D Expansion Boards (MicroTech III) Main Control Box F, A Fuse, Control Circuit, T Primary Main Control Box FC Fuse, Control Circuit, T Secondary Main Control Box F Fuse, Control Circuit Condenser Control Box F3 Fuse, Burner Motor Main Control Box F4 Fuse, T4 Transformer Main Control Box F6A, B, C Fuses, Unit Supplied Line Voltage Condenser Section F Fuse, SpeedTrol Motor Main Control Box F Fuse, SpeedTrol Motor Main Control Box FB8 Fuseblock, Main Transformer Main Control Box FB3-40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Section FB4-50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Section FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FS Freezestat Coil Section, Heat/Cool FSG Flame Safeguard Furnace Section GCB Generic Condenser Board Main Control Box GFS/GFR Ground Fault Sensor/Relay, RPS Unit Main Control Box GFS4/GFR4 Ground Fault Sensor/Relay, RCS Unit Cond. Control Box GRD Ground All Control Boxes GV Gas Valve, Pilot Furnace Section GV, 3 Gas Valves, Main Furnace Section GV4-8 Gas Valve, Hi-Turn Down Furnace Section Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

16 Electrical Legend Continued Schematic Sym. Description Location HL- 0 High Limits, Elec. Heaters (Top Bank) Electric Heat Section HL- 0 High Limits, Elec. Heaters (Bottom Bank) Electric Heat Section HL High Limit, Gas Heat (Prefilters) Supply Air Section HL3 High Limit, Gas Heat (Final Filter) Final Filter Section HL3-40 High Limits, Elec. Heaters (Top Bank) Electric Heat Section HL4-50 High Limits, Elec. Heaters (Bottom Bank) Electric Heat Section HP, High Pressure Controls Condenser Manifold HP5 High Pressure Control, Gas Furnace Section HS Heat Switch, Electric, Shutdown Main Control Box HTR- 6 Crankcase Heaters On Compressors IT Ignition Transformer Furnace Section LP, Low Pressure Controls, Refrigerant Condenser Manifold LP5 Low Pressure Control, Gas Furnace Section LT Light, Furnace On Furnace Section LT3 Light, Pilot Gas Valve On Furnace Section LT4 Light, Main Gas Valve On Furnace Section LT0 Light, Supply Fan Supply Air Section LT Light, Return Fan Return Air Section LT Light, Heat Section Heat Section LT3 Light, Filter Section Filter Section LT4 Light, Final Filter Section Final Filter Section LT5 Light, Discharge Section Discharge Section LT6 Light, Blow-through Coil Section Blow-Thru Coil Section LT7 Light, Evaporator Coil Section Evaporator Coil Section LT8 Light, Preheat Section Preheat Section LT9 Light, Blank Section Blank Section LT0 Light, Blank Compartment Blank Compartment LT Light, Condenser Section Condenser Section M- 6 Contactors, Compressors Main/Cond. Control Box M0 Contactor, Supply Fan Main Control Box M- 5 Contactors, Condenser Fans, Circuit # Cond. Control Box M0 Contactor, Return Fan Main Control Box M- 5 Contactors, Condenser Fans, Circuit # Cond. Control Box M9 Contactor, Burner Motor Furnace Section M30 Contactor, Supply Fan Inverter Inverter Bypass Box M3-39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Return Fan Inverter Inverter Bypass Box M4-50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M5, 5, 53 Contactors, Prop Exhaust Fan Motors Return Air Section MCB/MCB Microprocessor Control Board Main Control Box MJ Mechanical Jumpers Terminal Blocks MMP- 6 Manual Motor Protectors, Compressors Main/Cond. Control Box MMP0 Manual Motor Protector, Supply Fan Main Control Box MMP- 4 Manual Motor Protectors, Cond. Fans Ckt. Main/Cond. Control Box MMP0 Manual Motor Protector, Return Fan Main Control Box MMP- 5 Manual Motor Protectors, Cond. Fans Ckt. Main/Cond. Control Box MMP5, 5, 53 Manual Motor Protectors, Prop Exhaust Return Air Section MP- 6 Motor Protectors, Compressors On Compressors NB, Neutral Blocks Main Control Box NB3 Neutral Block Cond. Control Box OAE Outside Air Enthalpy Control Economizer Section OAT Outside Air Temperature Sensor Discharge Bulkhead Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

17 Electrical Legend Continued Schematic Sym. Description Location OL0 Overload Relays, Supply Fan Main Control Box OL0 Overload Relays, Return Fan Main Control Box OL5, 5, 53 Overload Relays, Prop Exhaust Fan Return Air Section PB Power Block, Total Unit or Cond./Heat Main Control Box PB Power Block, SAF/RAF/Controls Main Control Box PB3 Power Block, Electric Heat Electric Heat Section PB4 Power Block, Condenser Power Distribution Cond./RCS Control Box PB9, 0 Power Blocks, Supply Fan Unit Split Junction Box PB9, 0 Power Blocks, Return Fan Unit Split Junction Box PB3 Power Block, DS3 Power Distribution Electric Heat Control Box PB4 PB, Cond. Power Distribution (MicroTech II) RCS Control Box PC5 Pressure Control, Clogged Filter Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Filter PC8 Pressure Control, Minimum Airflow Evaporator Coil Section PC, Pressure Controls, FanTrol Cond. Bulkhead PC3, 3 Pressure Controls, Fan Condenser Section PS, Pumpdown Switches, Refrigerant Circuits Cond. Control Box PS3 Pumpdown Switch, Unit Main Control Box PVM, Phase Voltage Monitors, RPS Unit Main Control Box PVM4 Phase Voltage Monitor, RCS Unit Cond./Fuse Ctrl. Box R, Relays, High Pressure Reset Main/Cond. Control Box R5-8. Relays, Compressor, Safety/Cool Fail Main/Cond. Control Box R9, 0 Relays, Compressor Lockout Main/Cond. Control Box R, Relays, Low Ambient Main/Cond. Control Box R3-4. Relays, Compressor, Safety/Cool Fail Main/Cond. Control Box R, 3, 4 Relays, Condenser Fans Main/Cond. Control Box R8, 9 Relays, Cool Failure Indicator Main Control Box R0 Relay, HW, Steam or Electric Heat Main Control Box R0,, Relays, Gas Heat Furnace Section R3 Relay, Gas Heat Valve or Electric Heat Furnace or Elec. Ht. CB R4 Relay, Gas Heat Alarm Main Control Box R5 Relay, Gas Heat Start, Supply Fan Inverter Main Control Box R6 Relay, Occupied/Unoccupied Main Control Box R7 Relay, Exhaust Dampers Main Control Box R8 Relay, Isolation Dampers Main Control Box R9 Relay, Remote Fire Alarm Main Control Box R30 Relay, Cool Valve w/ F&B Main Control Box R45 Relay, UV Lights Main Control Box R46/47 Relay, Supply Fan Inverter increase/decrease Main Control Box R48/49 Relay, Return Fan Inverter increase/decrease Main Control Box R6 Relay, Special Main Control Box R63 Return Air Inverter Main Control Box R66 Relay, RA Smoke Detector Main Control Box R67 Relay, Supply Fan Enable Main Control Box R68 Relay, Return Fan Enable Main Control Box R69 Relay, Inverter Bypass VAV Box Interlock Main Control Box R8-88 Relays, Smoke Main Control Box RAE Return Air Enthalpy Sensor Return Air Section RAT Return Air Temperature Sensor Return Air Section REC Receptacle, Main Box Main Control Box REC Receptacle, Condenser Box Cond. Control Box Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

18 Electrical Legend Continued Schematic Sym. Description Location REC3 Receptacle, Field Power, 5V Discharge Bulkhead REC0-3 Receptacles, Cabinet Sections Cabinet Sections S Switch, System On/Off, RPS Unit Main Control Box S Switch, System On/Off, RCS Unit Cond. Control Box S3 Switch, Furnace On/Off Furnace Section S4 Switch, Inverter Bypass On/Off Main Control Box S6 Switch, Return Fan Vanes Adjustment Main Control Box S7 Switch, Local On/Off/Auto to Controller Main Control Box S0- Switches, Cabinet Section Lights Cabinet Sections S40-45 Switches, Door Interlock, UV Lights Cabinet Sections SD Smoke Detector, Supply Air Discharge Section SD Smoke Detector, Return Air Return Air Section SPS,, 3 Static Pressure Sensors, Duct or Building Main Control Box SPTRL Switch, Speedtrol Pressure Condenser Section SR- 3 Sequence Relays, Electric Heat Electric Heat Section SV- 4 Solenoid Valves, Liquid Discharge Bulkhead SV5-8 Solenoid Valves, Hot Gas Discharge Bulkhead T Transformer, Main Control Main Control Box T Transformer, Unit 4V Main Control Box T3 Transformer, Controller, 8V Main Control Box T4 Transformer, Exhaust Dampers Main Control Box T5 Transformer, Electric Heat Electric Heat Section T6 Transformer, Unit Supplied 0V Power Condenser Section T7 Transformer, Gas Pilot Valve Furnace Section T8 Transformer, Gas Main Valve Furnace Section T9 Transformer, 4V Refrigerant Circuit Main Control Box T Transformer, Speedtrol, 30V Cond. Control Section TB Terminal Block, 5V, Field Main/Cond. Control Box TB Terminal Block, 4V, Field Main/Cond. Control Box TB3, 4 Terminal Blocks, Condenser Cond. Control Box TB5 Terminal Block, 5V, Factory Main/Cond. Control Box TB6 Terminal Block, 5V/4V, Factory Main Control Box TB7, 8 Terminal Blocks, 4V, Factory Main Control Box TB0 Terminal Block, Heating Main Control Box TB Terminal Block, Heating Electric Heat Section TB, 3 Terminal Blocks, Electric Heat, Power Electric Heat Section TB5 Terminal 5V, Factory Unit Split Junction Box TB7, 8 Terminals 4V, Factory Unit Split Junction Box TC, Temperature Controls, FanTrol Cond. Control Box TC, 4 Temperature Controls, FanTrol Cond. Control Box TD, Time Delays, Compressor Lockout Main/Cond. Control Box TD0 Time Delay, Hi-Turn Down Burner Furnace Section TD0 Time Delay, Duct Hi Limit Main Control Box TR, Transducers, Pressure Main Control Box VM Valve Motor, Heating Heating Section VM5 Valve Motor, Cooling Coil Section, Cool VV Vent Valve Furnace Section ZNT Zone Temperature Sensor, Control Field Installed Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

19 Section A- Outdoor/Return Air Section Notes Primary Codes that pertain: 9, 0,,, 3 (Mid 0 & Earlier), 58 (Mid 0 & Later) Additional Codes that pertain: 06, 09,, 4, 5, 6, 7, 3 (Mid 0 & Later), 4, 33, 48, 49 Codes 9 and 0 determine the base section. Code 9 is the Return Air Plenum, and determines if the unit has back/ horizontal return air, bottom return air, left side return air, or side return air. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 0= B*, D*, E*, F*, G*, H*, J*). The only case in which a Plenum is not required is when a 00% Outdoor Air Damper and Hood are ordered (Code 0= AE, AY). Codes,, 3 (Mid 0 & Earlier) AND/OR 58 (Mid 0 & Later) determine the Return Air Fan, Motor and drive. These codes only pertain to units with a 0-00% Economizer (Code 0= D*, E*, F*, G* H*, J*). Return Air Fan section parts, Fan Wheels, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. Code 09, the voltage, is part of the Return Air Motor part number identification. Code, the control system, comes into play when an Economizer is present. The Economizer comes with an Actuator Motor on a MicroTech unit, but MAY OR MAY NOT come with a factory supplied Actuator if the unit has controls by others (Code = YC, YM). Codes 4 & 5 determine if the unit has a Return Air Fan Inverter/AFD/VFD and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4=, 4 there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller. Code 6 determines if a Smoke Detector is located in the Return Air Cabinet. If Code 6=, 3, a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/ HGRH inverter brand specified, and/or the presence of Intelligent Equipment. Code 4 determines if there are Prop Exhaust Fans present and if so, whether it is a -fan or 3-fan arrangement. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Code 33 also indicates if the unit is California Title 4 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Light, Switch, and Receptacle (Code 49= B, E), Fan Belt Guards (Code 49= D) or both (Code 49= F). Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

20 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood Code 0= AE, AY AND Code 9= YY No Return Air Plenum 9 4 Air Flow SectionB Ref. Part Actuator Qty. No. Description C0= AE C0= AY 4 Damper Assembly Damper Only Liner Panel- Hood Side Panel- Hood Side Panel- Hood Top Louver Channel- Support Channel- Support This Damper Assy. includes the Damper, Damper Linkage, and Actuator. For Damper Assy. components see the following two pages. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified. This Damper Assy. includes the Damper and Damper Linkage, but NO Actuator. For Damper Assy. components see the following page. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

21 Section A- Outdoor/Return Air Section 00% Outside Air Damper Detail w/act3 Code 0= AE, AY AND Code 9= YY Diagrams Motorized Linkage Detail: Code 0= AE Manual Linkage Detail: Code 0= AY Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

22 Section A- Outdoor/Return Air Section 00% Outside Air Damper Detail w/act3 Code 0= AE, AY AND Code 9= YY Components Ref. Part Actuator Qty. No. Description Code 0= AE Code 0= AY 4 Shaft- Linkage Not Used 5 Shaft Assembly Not Used Adapter Plate- CrankArm Not Used 7 Shaft- Linkage Not Used Channel- Support Not Used Blade- Damper Grille Stop/Anti- Rotate- Damper Support- Damper Motor Not Used Support- Damper Not Used Linkage Bar Drive Tab Not Used 0 Crank Arm- Damper Not Used Crank Arm- Adjustable Not Used Ball Joint- Damper Actuator- Motorized, 4V ACT Not Used 3 Bushing- Linkage Bar, Nylon Bushing- Damper Blade, Nylon Gasket- Vinyl Gasket- Vinyl Plug- Damper End Plug- Damper End Plug- Damper End Bearing- Flange Sleeve Not Used 40 Bearing- Sleeve Not Used Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

23 Section A- Outdoor/Return Air Section 0-30% Outside Air Section w/ ACT3 Code 0= BE, BY AND Code 9= BE, BY, HY Diagrams Linkage Detail: With Actuator Code 0= BE Linkage Detail: Without Actuator Code 0= BY 48 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

24 Section A- Outdoor/Return Air Section 0-30% Outside Air Section w/ ACT3 Code 0= BE, BY AND Code 9= BE, BY, HY Components Ref. Part Actuator Qty. No. Description C0= BE C0= BY,HY Damper Assembly- Complete Damper Only Blade- Damper Gasket- Vinyl Gasket- Vinyl Seal- End Grille Support- Motor Not Used Rod- Support Angle Not Used Bar- Linkage Shaft- Linkage Louver Plug- End Plug- End Bushing- Damper Blade Bushing- Linkage Bar, Nylon Ball Joint- Damper Not Used 35 Actuator- Motorized, 4V ACT Not Used 36 Crank Arm- Damper Not Used 47 Bearing- Flange Not Used 48 Retainer- Actuator Not Used N/S= Not Shown on Diagram. Damper Assembly includes the Damper, Damper Linkage, and Actuator. Damper Assembly includes the Damper, Damper Linkage, but NO Actuator. 3 Damper only, no Actuator Linkage or Actuator. 4 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

25 Section A- Outdoor/Return Air Section 0-00% Economizer Section w/ Barometric Exhaust Damper Units w/o Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, GE, GY, KE, KY AND Code = YYYY Back Return (Code 9= HY) shown. Air Flow Ref. Part Part Qty. No. Description Number Economizer Damper w/ Act.(Code 0= DE, EE, FE, GE) w/o Act. (Code 0= DY, EY, FY, GY) Exhaust Damper Assembly Powered (Code 0= EE, EY, GE, GY) Barometric (Code 0= DE, DY, FE, FY) N/S= Not Shown on diagram. Economizer detail two pages after next. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

26 Section A- Outdoor/Return Air Section 0-00% Economizer Section w/ Barometric Exhaust Damper Units w/ 44 Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, GE, GY, KE, KY AND Code = 44B* 6 (see Return Fan Detail) Bottom Return (Code 9= BY, BE, BD, BE) shown (see Return Fan Detail) 6 Ref. Part Part Qty. No. Description Number Economizer Damper w/ Actuator Code 0= DE, EE, FE, GE w/o Actuator Code 0= DY, EY, FY, GY Exhaust Damper Assembly Powered Code 0= EE, EY, GE, GY Barometric Code 0= DE, DY, FE, FY Gasket.5 x Gasket Gasket Gasket Gasket Fan Guard Fan Guard Fan Guard N/S= Not Shown on diagram. Economizer detail on page after next. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

27 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Prop Exhaust Fan & Damper Code 0= HE, HY, JE, JY, ME, MY AND Code 4=, 3 Diagrams Section Assembly Detail fan arrangement shown (Code 4= ) 0 40 Fan Guard Ref. Part Part Qty. 3 No. Description Number 40 Fan Assembly, Std. Motor, 08/30/ Code, 3= **Y 05660, Fan Assembly, Std. Motor, Code, 3= **Y 05660, Fan Assembly, Grounded Motor, 08/30/ Code, 3= **S , Fan Assembly, Grounded Motor, Code, 3= **S , 5 Fan Guard Panel- Weather Hood Hood- Prop Exhaust 830 Grille Only- Prop Exhaust Hood 80 N/S= Not Shown on diagram. See detail following Isolation Damper Detail. Quantity may be two (Code 4= ) OR three (Code 4= 3). 3 Quantity is PER fan. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

28 Section A- Outdoor/Return Air Section 0-00% Economizer Damper Detail Code 0= DE, DY, EE, EY, FE, FY, GE, GY, HE, HY, JE, JY Diagrams Linkage Detail: With Actuator Code 0= *E AND MTII OR No Controls Linkage Detail: With Actuator Code 0= *E AND MTIII Controls Linkage Detail: Without Actuator Code 0= *Y Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

29 Section A- Outdoor/Return Air Section 0-00% Economizer Damper w/ ACT3 Code 0= D*, E*, F*, G* H*, J* Components Ref. Part Actuator Qty. No. Description C0= *E C0= *Y Damper Assembly- Complete Damper Only Shaft Assembly Not Used 5 Shaft Assembly Not Used Plate- Crank Arm Microtech II Controls Code = *D, *S Not Used Microtech III Controls Code = *E, *F, *W Not Used No Controls Code = YM, YC Not Used Shaft Assembly Not Used Shaft- Linkage Channel- Support Code = *E, *F, *W Not Used Channel- Support Not Used Blade- Damper Stop/Anti-Rotate- Damper Support- Damper Motor Microtech II Controls Code = *D, *S Not Used No Controls Code = YM, YC Not Used Channel- Support Not Used Bar- Linkage Drive Tab- Linkage Bar Crank Arm- Damper Microtech II Controls Code = *D, *S Not Used No Controls Code = YM, YC Not Used Crank Arm- Adjustable Not Used Ball Joint- Damper Actuator ACT3 Microtech II Controls, 0V Code = *D, *S Not Used Microtech III Controls, 4V Code = *E, *F, *W Not Used No Controls, 0V Code = YM, YC Not Used 3 Bushing- Linkage Bar Bushing- Damper Blade Gasket- Vinyl Gasket- Vinyl End Plug- Damper End Plug- Damper End Plug- Damper Bearing- Sleeve Code = *E, *F, *W Not Used 3 Bracket Support- Actuator Code = *E, *F, *W Not Used N/S Gasket- Neoprene N/S= Not Shown on Diagram. Damper Assy. includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Damper Assy. includes the Damper, Damper Linkage, but NO Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. 3 Damper only, no Actuator Linkage, OR Actuator. 4 Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel. 5 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

30 Section A- Outdoor/Return Air Section California Title 4 Assembly Code 33 (Mid 0 & Later) = *F*** Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch Bracket, Mounting Switch Switch, Push Button SPDT Bushing, Conduit 3630 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 30

31 Section A- Outdoor/Return Air Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE ACT6 Actuator Detail Ref. Part Part Qty. No. Description Number Isolation Damper Assembly- Complete Motor Mount Assembly Blade Assembly- Return Angle- Linkage Angle- Blade Shaft- Damper Blade Shaft- Linkage Bearing- Flange, Nylon Actuator- Motorized, 4V ACT Crank Arm- Damper Ball Joint Bearing- Sleeve Gasket- Vinyl Bracket Support- Actuator Retainer- Actuator Bearing- Sleeve Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

32 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Detail Code 0= HE, HY, JE, JY, AND Code 4=, 3 6 Fan Assembly Components Fan Arrangement Shown Code 4= 54 5 B A 6C 6B 6D 6E 6F 6G 6H 6A Lube Line Detail 53 Control Box (see following pages) 6I Voltage Ref. Sch. Part Part No. Sym. Description Number AFD0 Inverter see charts on the following pages A Resistor- Inverter B Jumper- Inverter Fan Assembly- Complete Fan Assembly- Complete A Damper- Backdraft 3 6B Fan Prop C Fan Shaft D Bearing E Fan Sheave F Bushing- Fan Sheave G Belt H Motor Sheave I Motor Motor Tube- Plastic Coupling- Tube.5 x.5 FPT Fitting- Grease Quantity= when Inverter model 3500 (Code 5= G) is used. Quantity shown is for fans. Quantities for 3 fan units: Ref. 5= 3 ; Ref. 53= 6; Ref. 54= 6. 3 Contact Daikin Applied. 4 Quantity is PER fan. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

33 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Detail Code 0= HE, HY, JE, JY AND Code 4=, Continued 03/3 & Earlier Inverter- Fan Units (Code 4= ) Voltage Code Inverter Model Part 5= Number A G R VTAC VTAC S MD MD V 30V Inverter- 3 Fan Units (Code 4= 3) Voltage Code Inverter Model Part 5= Number A G R VTAC VTAC S MD MD V 30V Prop Exhaust Fan Control Box OL5 M5 OL5 M5 0 Contactor & Overload Detail Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5-53 Overload Overload Overload Overload M5-53 Contactor 8A Contactor 9A V 30V Fan Unit shown 30 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 33

34 Inverter- Fan Units (Code 4= ) Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Detail Code 0= HE, HY, JE, JY AND Code 4=, Continued Voltage Code Inverter Model Part 5= Number A B MD MD G Q MD MD R VTAC VTAC S, Q MD MD B MD MD MD V 30V 04/3 & Later Inverter- 3 Fan Units (Code 4= 3) Voltage Code Inverter Model Part 5= Number A G R VTAC VTAC S, Q MD MD B MD MD MD V 30V Prop Exhaust Fan Control Box 0 30 OL5 OL5 M5 M5 Fan Unit shown 0 30 Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5-53 Overload Overload Overload Overload M5-53 Contactor 5A Contactor 6A Contactor 9A Contactor 7A NOTE: Quantities listed are for a 3 Fan unit (Code 4= 3). 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 34

35 LH Louvered Door Assy. Section Final Assembly Section A- Outdoor/Return Air Section Design Flow Detail Code 0= FE, FY, GE, GY Louvered Door Assembly Detail 4 3 RH Louvered Door Assy Design Flow Vane and Vane Bearings Detail Adjuster Control Assy. Detail 30 Spring Detail Ref. Part Part Qty. No. Description Number Louver Panel Left Hand Door Louver Panel Right Hand Door Grille Gasket Gasket Potentiometer O Ring- Potentiometer Panel- Vane Shaft- Upper Bearing- Lower Crank Arm Assembly Left Hand Door Crank Arm Assembly Right Hand Door Link Arm 0 Bearing Bearing Spring- Main Spring- Secondary N/S Leveling Kit- Design Flow Quantity is PER door. P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 35

36 Section A- Outdoor/Return Air Section Return Air Fan Detail (Code = 44B, 44B, 44B3) Ref. Motor Part Part Qty. No. HP Description Number Motor see one & two pages after next 4 All Mount- Motor All Channel Assembly All Adjustment Bolt Assy., Motor Base All Clamp- Motor Channel All Clamp- Motor Channel All Shaft- Fan.438 dia All Tubing- Plastic All Coupling All Coupling All Fitting- Grease /8 MPS All Bearing-.437 Opposite Drive End All Bearing-.437 Drive End All Key- Wheel 5/8 X 6½ All Key- Fan Sheave 5/8 x 5½ All Wheel- SISW All Funnel- Inlet All Lock Collar All Lock Washer All Cap Screw Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 36

37 Section A- Outdoor/Return Air Section Return Air Fan Detail- Fan Mounts Rubber Mounts Rubber Mounts (Code = 44B OR 44W) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Red , 60 Rubber Mount- Black Rubber Mount- Red , 60 Rubber Mount- Black All Rubber Mount- Red All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or 6 or 6 6 Mounting Diagram 63 or or Spring Mounts 64 Seismic strap used only when Code = 44B Spring Mounts (Code = 44B) OR Seismic Spring (44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code = 44B Seismic Code = 44B Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black Spring Mount- Brown Spring Mount- Red Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black Spring Mount- Brown Spring Mount- Red All Nut Spring Code = 44B Seismic Code = 44B All Nut All Screw Spring Code = 44B 0470 Seismic Code = 44B Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 37

38 Section A- Outdoor/Return Air Section Return Air Fan Motors Standard Motors: Code = **Y H.P. Motor HP Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff C=**Y Voltage C= *EY C= *JY C= *GY C= *KY C09= 5 J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ P*Y 08/60/ Q*Y 08/60/ R*Y 08/60/ S*Y 08/60/ T*Y 08/60/ N/A C09= 9 5 J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ P*Y 30/60/ Q*Y 30/60/ R*Y 30/60/ S*Y 30/60/ T*Y 30/60/ N/A C09= 7 5 J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ R*Y 460/60/ S*Y 460/60/ T*Y 460/60/ C09= 37 5 J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ R*Y 575/60/ S*Y 575/60/ T*Y 575/60/ N/A= Not Available. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 38

39 Section A- Outdoor/Return Air Section Return Air Fan Motors Shaft Grounded Motors: Code = **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C= **S Voltage C= *JS C= *KS C09= 5 J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ P*S 08/60/ Q*S 08/60/ R*S 08/60/ S*S 08/60/ T*S 08/60/ N/A C09= 9 5 J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ P*S 30/60/ Q*S 30/60/ R*S 30/60/ S*S 30/60/ T*S 30/60/ C09= 7 5 J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ R*S 460/60/ S*S 460/60/ T*S 460/60/ C09= 37 5 J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ R*S 575/60/ S*S 575/60/ T*S 575/60/ N/A= Not Available. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 39

40 Section A- Outdoor/Return Air Section Section Mounted Controls OAE, RAE, LT, S, REC Bottom Return Shown Code 9= BY, BE Economizer Damper 40 4 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n & Mount Minor field modifications are required for proper installation & operation when changing to the newer design. Bottom Return Shown Code 9= BY, BE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE BOTH original controls are obsolete & no longer available. For the OAE Control use & Mount For the RAE Control use & Mount Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay (OAER), are required for proper installation & operation. 30 Back Return Code 9= HY 7 Return Air Opening 30 Return Air Opening Bottom Return Code 9= BY, BE RAT- Outdoor Air Temperature Sensor Ref. Part Part Qty. No. Description Number 7 Return Air Temp. Sensor- RAT (MTII) Return Air Temp. Sensor- RAT (MTIII) SD- Return Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 30 Smoke Detector SD LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Light Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 40

41 Section B- DrawThru Filter/Blank Section Notes Primary Codes that pertain: 5, 33 (Mid 0 & Later) Additional Codes that pertain: 06, 9, 0 Code 5 determines all of the section characteristics. Refer to the Nomenclature, Unit Code Index section for an explanation of Filter codes. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter gauge. Even though the gauge may be located in several different places in the unit, the p/n is listed in this section for convenience. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank Access Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. Codes 9 and 0 determine Return Air section characteristics which has an effect on the final assembly panels. Section Mounted Controls PC5, LT3, S3, REC3 & Magnehelic/Differential Pressure Gauge Controls PC5 Ref. Part Part Qty. No. Description Number 65 PC5 Pressure Ctl LT3- Filter Section Light/S3- Filter Section Light Switch/REC3- Filter Section Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Magnehelic/Differential Pressure Gauge Code 33= A****, B****, C**** (Mid 0 & Later) Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0-3 WC Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

42 Section B- Draw-Thru Filter/Blank Section Filters Typical Angular Filter Section Shown Code 5= A* Ref. Part Code Part Qty. No. Description 5= Number Angular Filter Section (Code 5= A*, D*, E*, G*) N/S Filter 30% Pleated, 6 x 5 x " MERV 8 *B % Pleated, 6 x 5 x " w/ Intersept MERV 8 *C % Disposable, 6 x 5 x MERV 3 *H N/S Filter 30% Pleated, 6 x 0 x MERV 8 *B % w/ Intersept, 6 x 0 x " w/ Intersept MERV 8 *C % Disposable, 6 x 0 x MERV 3 *H 9005 N/S Media Filler Piece ALL N/S Angle Assembly ALL Flat Filter Section (Code 5= F*, H*) N/S Filter, Cartridge 65% Cartridge, 4 x 4 x " MERV *D % Cartridge, 4 x 4 x " MERV 4 *E % Cartridge, 4 x 4 x " w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x " MERV *D % Cartridge, x 4 x " MERV 4 *E % Cartridge, x 4 x " w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL 0460 Gasket, Pre Filter ALL N/S Pre Filter, x 4 x ALL Gasket, Pre Filter ALL Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. Optional- Angle is mounted on leaving air side. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

43 Section B- Draw-Thru Filter/Blank Section Filters, Continued & Air Blender Filters, Continued Ref. Part Code Part Qty. No. Description 5= Number Staggered Filter Section (Code 5= S*, T*, V*) 65% Cartridge, 4 x 4 x MERV *D % Cartridge, 4 x 4 x MERV 4 *E % Cartridge, 4 x 4 x w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D % Cartridge, x 4 x MERV 4 *E % Cartridge, x 4 x w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL Gasket, Pre Filter ALL Staggered Filter Section (Code 5= L*) 65% Cartridge, 4 x 4 x MERV *D % Cartridge, 4 x 4 x MERV 4 *E % Cartridge, 4 x 4 x w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D % Cartridge, x 4 x MERV 4 *E % Cartridge, x 4 x w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL Gasket, Pre Filter ALL N/S Pre Filter, x 4 x ALL Gasket, Pre Filter ALL Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. Air Blender Air Blender (Code 5= D*, E*, G*, H*, T*, V*) OR Code 50 [Mid 0 & Later]= L, H) Ref. Part Part Qty. No. Description Number 65 Panel- Access Air Blender Plate- Economizer Linkage Access Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 43

44 Section C- Draw-Thru Blank Access Section OR Separate Inverter Section Notes Primary Codes that pertain: 6, 4, 5 Additional Codes that pertain: 06 Code 6 determines if a section is installed and if so, the size of the section. If Code 6= E there is a 4 Blank/ Empty section; if Code 6= F, S there is a blank 48 section; if Code 6= Y, there is no section. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4=,, 4 there is a separate Inverter Section. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4= Y, there are no inverters. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied..the Inverter with Bypass is shown below. All components pertaining to the Inverter are listed in the Supply Air Section (Section F). Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank compartment, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. Return Air Inverter (AFD0) Overload (OL0- Supply Air) (OL0- Return Air) Supply Air Inverter (AFD0) Power Block (PB0- Supply Air) (PB0- Return Air) Section Mounted Controls LT7, S7, REC Contactor (M30A/M30B- Supply Air) (M40A/M40B- Return Air) LT7- DT Access Section Light/S7- DT Access Section Light Switch/ REC7- DT Access Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC NOTE: Some RPS/RFS/RDT units may have a Draw-Thru Preheat Coil. This is a hydronic heating coil that sits between the filter and the cooling coil. The preheat coils used in this position are the same as those used in Section E (RDT Draw-Thru heat section). Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 44

45 Section D- Draw-Thru Cooling Section Notes Primary Codes that pertain: 03, 7, 8 Additional Codes that pertain: 06 Code 03 determines the DX cooling coil size. If Code 03= S there is a small face area coil (4 section for unit sizes D or 48 section for unit sizes 00-0D), and if Code 03= L it is a large face area coil (48 section for unit sizes D or 4/48 for unit sizes 00-40D). Note that Code 03 is always L on unit sizes 5-40D. Code 7 determines if there is a Section D. If Code 7= YYYY, then there is no section For RPS OR RFS units this indicates that the cooling coil is in the BlowThru position. (RDT units always have a section D). If the first three digits of Code 7= DYY then the section contains only a Drain Pan in a 48 section. If the first three digits of Code 7= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 7= S, the Drain Pan is stainless steel, P, Y in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 7= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 7= L, T then the first three digits of Code 7 must equal DYY. Code 8 will apply only if Code 7= CYYY, CYYS, and determines the DrawThru Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. NOTE: The drawings and components listed in this section also apply to Section I Blow-Thru Cooling Section- RPS OR RFS units. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 45

46 Small Face Area Coil 4 Section Code 03= S Unit Sizes 080, 085, 090D Section D- Draw-Thru Cooling Section Evaporator Coils, Drain Pans, Gasketing Small Face DX Coils (Code 03= S) Ref. Part Part Qty. No. Description Number 3 Coil 0 Drain Pan Galvanized C7= CYYY Stainless C7= CYYS Pan- Auxiliary Galvanized C7= CYYY Stainless C7= CYYS Gasket Gasket 094 Contact Daikin Applied with unit GO and/or serial number. For Drain Pans and components when Code 7= GYY* and/ or Code 7 Digit 4= L, T, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Small Face Area Coil 48 Section Code 03= S Unit Sizes 00, 05, 0, 0D Ref. Part Part Qty. No. Description Number 3 Coil- Upper 3 4 Coil- Lower 3 0 Drain Pan 4 Galvanized C7= CYYY Stainless C7= CYYS Drain Pan Galvanized C7= CYYY Stainless C7= CYYS Pan- Liner Pan- Auxiliary Gasket Gasket Gasket Contact Daikin Applied with unit GO and/or serial number. 4 For Drain Pans and components when Code 7= GYY* and/ or Code 7 Digit 4= L, T, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 46

47 Section D- Draw-Thru Cooling Section Large Face DX Evaporator Coils (Code 03= L) Large Face Area Coil 48 Section unit sizes D 4/48 Section unit sizes 00-40D Code 03= L ( D shown) Base- 080, 090D 39 Base D 48 Section: D Ref. Part Part Qty. No. Description Number 3 Coil- Lower 4 Coil- Upper 0 Drain Pan Galvanized Code 7= CYYY Stainless Code 7= CYYS Drain Pan Galvanized Code 7= CYYY Stainless Code 7= CYYS Pan- Liner Pan- Auxiliary Gasket Gasket Gasket Contact Daikin Applied with unit GO and/or serial number. 4/48 Section: 00-40D Ref. Part Part Qty. No. Description Number 3 Coil- Lower 4 Coil- Upper 0 Drain Pan Galvanized Code 7= CYYY Stainless Code 7= CYYS Drain Pan Galvanized Code 7= CYYY Stainless Code 7= CYYS Pan- Liner Pan- Auxiliary Gasket Gasket Gasket Contact Daikin Applied with unit GO and/or serial number. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 47

48 Section E- Spacer Section (RPS/RFS) Notes Primary Codes that pertain: 30 Additional Codes that pertain: 06 Code 30 determines all of the section characteristics. For RPS/RFS units if Code 30= BBBBBB, FFFFFF, there is a 48 blank section; if Code 30= EEEEEE, there is a 4 blank section; and if Code 30= YYYYYY, there is no section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Spacer Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section I. Section Mounted Controls LT8, REC8, S8- Section Mounted Light LT8- Spacer Section Light/S8- Spacer Section Light Switch/ REC8- Spacer Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Section E- Draw-Thru Heat Section (RDT) Notes Primary Codes that pertain: 04, 30 Additional Codes that pertain: 06 Code 04 determines what type of heat has been specified. DrawThru Heat units normally are hydronically heated with Steam (Code 04= S) or Hot Water (Code 04= H). NOTE: There are some DrawThru Electric Heat RDT units. See Section G (BlowThru Heat) for all Electric Heat components. Code 30 determines the Hydronic Heating Coil s associated characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 48

49 Section E- Draw-Thru Heat Section (RDT) Hot Water OR Steam Coil Heat, Mixing Valves, & Actuator VM RDT Code 30 first 3 digits= S, S, S3, S4, W, W Coil Location Mixing Valve Detail (HW shown) Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30 OR 5= Type Height Number Steam Heat Coil- Bottom S*** 5JA060H Steam Heat Coil- Bottom S*** 5JA0H Steam Heat Coil- Bottom S3*** 5JA060C Steam Heat Coil- Bottom S4*** 5JA0C Hot Water Heat Coil- Bottom W*** 5WH090H Hot Water Heat Coil- Bottom W*** 5WS090C Steam Heat Coil- Top S*** 5JA060H Steam Heat Coil- Top S*** 5JA0H Steam Heat Coil- Top S3*** 5JA060C Steam Heat Coil- Top S4*** 5JA0C Hot Water Heat Coil- Top W*** 5WH090H Hot Water Heat Coil- Top W*** 5WS090C N/S Valve, Way Steam Heat w/ Act..5 S**EE 5JA All S**FE 5JA All S**GE 5JA All S**HE 5JA All VM Actuator- 4V, Valve W****E All All Actuator- 4V, Valve W****E All All Valve, 3 Way HW w/ Actuator.5 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All W**H3E 5WH, 5WS All W**J3E 5WH, 5WS All N/S= Not shown on diagram. Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 49

50 Section F- Supply Air Section Notes Primary Codes that pertain: 3, 3, 33, 59 (Mid 0 & Later), 08, 4, 5, 40, 49 Additional Codes that pertain: 04, 06, 6, 7, 3 (Mid 0 & Later), 33 (Mid 0 & Earlier), 34, 48 Code 3 determines the Supply Fan size and type, Code 3 determines the Motor horsepower and type, and Code 33 (Mid 0 & Earlier) OR Code 59 (Mid 0 & Later) determine the drive selection. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 08 determines the location of the unit s Main Control Box. Note that RDT units normally have Main Control Boxes in the Supply Air Section. Codes 4 & 5 determine if the unit has inverter(s), and if so where they are installed. If Code 4= Y, there are no inverters. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4=,, 4, there is a separate Inverter Section. Code 5 specifies the inverter brand. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied. Code 40 determines the Discharge Plenum configuration. The Discharge Plenum is located in Section F when the section is bolted directly to the Condenser (Section M). RDT units always have the discharge plenum located in Section F. If Code 40= BE, there is an Isolation Damper with Actuator ACT5. This damper is detailed in Section K. Code 49 determines if the Supply Air cabinet has a Belt Guard (Code 49=A, D), a Fan Section Light (Code 49= B, E), or both (Code 49= C, F). Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, the location of the discharge plenum, as well as the section installed controls. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. Code 6 determines if a Smoke Detector is located in the Supply Air Cabinet. If Code 6=, 3, a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 7= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 7 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 5V Service Outlet, and/or Intelligent Equipment. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls, Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 3= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified. Code 48 determines if the unit is equipped with Hot Gas Reheat and/or IBC seismic construction. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 50

51 Section F- Supply Air Section Air Foil Fan- Double Width Code 3= 33A, 33A, 33A3, 36A, 36A, 36A3, 40A, 40A, 40A Wheel Detail (View when FACING discharge opening.) 6 5 Ref. Part Part Fan Size No Description Number Motor- see listing at end of section F Housing Assy.- Blower Inlet Funnel Only Housing Assy.- Blower Inlet Funnel Only Housing Assy.- Blower Inlet Funnel Only Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Screw Adjust Assembly Shaft.438 Diameter Shaft.688 Diameter Shaft.938 Diameter Motor Mount Assembly Angle- Motor Mount Holddown Angle, Clamping Key- Fan 4.75 Long X 5/8 Diameter 0367 Key- Fan 0.00 Long X 5/8 Diameter 0363 Key- Fan 5.50 Long X 3/4 Diameter 0370 Key- Sheave 6.50 Long X / Diameter 0360 Key- Sheave 5.50 Long X 3/4 Diameter Bearing- Ball.437 Bore Bearing- Ball.688 Bore Bearing- Ball.937 Bore Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

52 Section F- Supply Air Section Air Foil Fan- Single Width- RDT (Draw-Thru/No Heat) Units Code 3= 44B, 44B, 44B3, 49B, 49B, 49B Ref. Part Part Fan Size No. Description Number Motor- see table at end of Section F 3 Wheel, Fan- Single Inlet/Single Width Wheel, Fan- Single Inlet/Single Width Inlet Funnel Assembly Inlet Funnel Assembly Screw Adjust Assembly Shaft.438 Diameter Shaft.88 Diameter Mount Assembly- Motor Angle- Motor Mount Angle, Clamping Key- Fan 6.50 Long X 5/8 Diameter 0360 Key- Fan 6.00 Long X / Diameter 0350 Key- Fan 5.50 Long X 5/8 Diameter Key- Fan 6.00 Long X / Diameter Tubing- Plastic Tubing- Plastic Bearing- Ball.437 Bore Bearing- Ball.88 Bore Fitting- /4 OD X /8 MPT Fitting- /4 OD X /8 FPT Bearing- Ball.437 Bore Bearing- Roller.88 Bore Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

53 Section F- Supply Air Section Fan Mounts- 33 Airfoil Double Width Fan Code 3= 33A, 33A, 33A3 6 or 6 Mount Locations 63 or 63 6 or 6 64 or Rubber Mounts Spring Mounts Seismic strap used only when Code 3= 33A Rubber Mounts (Code 3= 33A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support , 7.5 Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green Rubber Mount- Black Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts (Code 3= 33A) OR Seismic Spring (Code 3= 33A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 33A Seismic Code 3= 33A , 7.5 Spring Mount- Purple Spring Mount- Brown , 50 Spring Mount- Red All Spring Mount- Brown , 7.5 Spring Mount- Brown Spring Mount- Red , 50 Spring Mount- Red/Black All Spring Mount- Red All Nut Spring Code 3= 33A Seismic Code 3= 33A All Nut All Screw Spring Code 3= 33A 0470 Seismic Code 3= 33A Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 53

54 Section F- Supply Air Section Fan Mounts- 36 Airfoil Double Width Fan Code 3= 36A, 36A, 36A Rubber Mounts Rubber Mounts (Code 3= 36A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support All Rubber Mount- Red , Rubber Mount- Red , 60, 75 Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green , 75 Rubber Mount- Gray All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or 6 Mount Locations 63 or or or Spring Mounts Seismic strap used only when Code 3= 36A Spring Mounts (Code 3= 36A) OR Seismic Spring (Code 3= 36A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 36A Seismic Code 3= 36A , 5 Spring Mount- Brown Spring Mount- Red , 75 Spring Mount- Red/Black All Spring Mount- Brown , 5 Spring Mount- Red Spring Mount- Red/Black , 75 Spring Mount- Red/Green Spring Mount- Red Spring Mount- Red/Black All Nut Spring Code 3= 36A Seismic Code 3= 36A All Nut All Screw Spring Code 3= 36A 0470 Seismic Code 3= 36A Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 54

55 Section F- Supply Air Section Fan Mounts- 40 Airfoil Double Width Fan Code 3= 40A, 40A, 40A3 6 or Rubber Mounts Mount Locations Rubber Mounts (Code 3= 40A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Red , 75 Rubber Mount- Green Rubber Mount- Red Rubber Mount- Black , 5 Rubber Mount- Red Rubber Mount- Green , 75 Rubber Mount- Gray All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or or or Spring Mounts Seismic strap used only when Code 3= 40A Spring Mounts (Code 3= 40A) OR Seismic Spring (Code 3= 40A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 40A Seismic Code 3= 40A Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black All Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black Spring Mount- Red/Green Spring Mount- Red Spring Mount- Red/Black All Nut Spring Code 3= 40A Seismic Code 3= 40A All Nut All Screw Spring Code 3= 40A 0470 Seismic Code 3= 40A Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 55

56 Section F- Supply Air Section Fan Mounts- 44 AFSW- Draw-Thru/No Heat Units Code 3= 44B, 44B, 44B3 Mount Locations 6 6 or 63 or or or Rubber Mounts 6 6 Spring Mounts Seismic strap used only when Code 3= 44B Rubber Mounts (Code 3= 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Red , 0 Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts (Code 3= 44B) OR Seismic Spring (Code 3= 44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 44B Seismic Code 3= 44B Spring Mount- Purple Spring Mount- Brown Spring Mount- Red All Spring Mount- Brown Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black All Spring Mount- Red All Nut Spring Code 3= 44B Seismic Code 3= 44B All Nut All Screw Spring Code 3= 44B 0470 Seismic Code 3= 44B Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 56

57 Section F- Supply Air Section Fan Mounts- 49 AFSW- RDT Units Code 3= 49B, 49B, 49B3 6 or 6 6 or 6 64 or or Rubber Mounts 6 6 Spring Mounts Seismic strap used only when Code 3= 49B Rubber Mounts (Code 3= 49B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support All Rubber Mount- Red All Rubber Mount- Red Rubber Mount- Red Rubber Mount- Green Rubber Mount- Red Rubber Mount- Green All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts (Code 3= 49B) OR Seismic Spring (Code 3= 49B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 49B Seismic Code 3= 49B Spring Mount- Red , 50 Spring Mount- Red/Black , 75 Spring Mount- Red/Green All Spring Mount- Red/Black Spring Mount- Red Spring Mount- Red/Black All Spring Mount- Red/Black All Nut Spring Code 3= 49B Seismic Code 3= 49B All Nut All Screw Spring Code 3= 49B 0470 Seismic Code 3= 49B Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 57

58 H.P. Motor HP Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff C3= **Y Voltage C3= *EY C3= *JY C3= *GY C3= *KY C09= 5 J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ P*Y 08/60/ Q*Y 08/60/ R*Y 08/60/ S*Y 08/60/ T*Y 08/60/ N/A 75 U*Y 08/60/ N/A C09= 9 5 J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ P*Y 30/60/ Q*Y 30/60/ R*Y 30/60/ S*Y 30/60/ T*Y 30/60/ U*Y 30/60/ C09= 7 5 J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ R*Y 460/60/ S*Y 460/60/ T*Y 460/60/ U*Y 460/60/ C09= 37 5 J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ R*Y 575/60/ S*Y 575/60/ T*Y 575/60/ U*Y 575/60/ N/A= Not Available. Section F- Supply Air Section Supply Air Fan Motors Standard Motors: Code 3= **Y Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 58

59 Section A- Outdoor/Return Air Section Supply Air Fan Motors Shaft Grounded Motors: Code 3= **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C3= **S Voltage C3= *JS C3= *KS C09= 5 J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ P*S 08/60/ Q*S 08/60/ R*S 08/60/ S*S 08/60/ T*S 08/60/ N/A 75 U*S 08/60/ N/A C09= 9 5 J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ P*S 30/60/ Q*S 30/60/ R*S 30/60/ S*S 30/60/ T*S 30/60/ U*S 30/60/ C09= 7 5 J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ R*S 460/60/ S*S 460/60/ T*S 460/60/ U*S 460/60/ C09= 37 5 J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ R*S 575/60/ S*S 575/60/ T*S 575/60/ U*S 575/60/ N/A N/A= Not Available. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 59

60 Section F- Supply Air Section Belt Guard Code 49= A, C, D, F 4 40 Air Foil Double Width (AFDW) Ref. Part Part Fan Size No. Description Number Grille Assembly Grille Assembly Grille Assembly Belt Guard Assembly Belt Guard Assembly Belt Guard Assembly Air Foil Single Width (AFSW) with Side Discharge (Code 40= H), Main Control Box (Code 08= S, F) The Main Control Box is mounted in this section on RDT units (the supply air section is mounted directly to the condenser section). Air Foil Single Width (AFSW) with Side Discharge (Code 40= S), No Control Box (Code 08= P, D) RPS units (Main Control Box is mounted in the Discharge Plenum Section K) Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= G), Main Control Box (Code 08= S, F) The Main Control Box is mounted in this section on RDT units (the supply air section is mounted directly to the condenser section) Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= B), No Control Box (Code 08= P, D, Y) RPS units (Main Control Box is mounted in the Discharge Plenum Section K) Ref. Part Part Fan Size No. Description Number Grille Assembly Grille Assembly Grille Assembly Grille Assembly Grille Assembly Grille Assembly Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 60

61 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/3 & Earlier) Motor HP 5 (Code = J**; OR Code 3= J**) 7 LR0 (Supply) LR0 (Return) MMP30 (Supply) MMP40 (Return) 70 Bypass Controls Detail 7 M30B/M30I (Supply) M40B/M40I (Return) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 3, 5, 8) Two boxes installed if Code 4= Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) 74 7 MMP & Contactor Link Detail Motor HP 5 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see Inverter section Front Mounted, NO OR NC. 08V 30V 50 Gasket MMP30,40 Motor Control LR0,0 Line Reactor- see page following inverters 7 M30B,I Contactor M40B,I Contact- Auxiliary Link Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

62 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/3 & Later) Motor HP 5 (Code = J**; OR Code 3= J**) MMP30 (Supply) MMP40 (Return) 7 7 LR0 (Supply) LR0 (Return) Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box shown. (Code 4= 3, 5, 8) Two boxes installed if Code 4= 5 Phase Barrier 70A Front Mtd. Aux. Contact MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) Link 70C 7 7A Spacer Contactor MMP30/40 & M30/40 Link Detail 5 HP Motors- 08/30V Link 70C 7 Contactor MMP30/40 & M30/40 Link Detail 5 HP Motors- 460/ Motor HP 5 Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 0 Inverter- see Inverter section 08V 30V 50 Gasket MMP30, 40 Motor Protector A Phase Barrier B Aux. Contact C Link LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I A Spacer Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

63 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/3 & Earlier) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) MMP30 (Supply) MMP40 (Return) 7 LR0 (Supply) LR0 (Return) 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) Two boxes installed if Code 4= 5 7 M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail MMP & Contactor Link Detail MMP p/n xx MMP & Contactor Link Detail MMP p/n , 48, 49 MMP & Contactor Link Detail MMP p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 63

64 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/3 & Earlier) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30,40 Motor Control LR0, 0 Line Reactor- see page after inverters 7 M30B,I Contactor M40B,I Contact- Auxiliary Link Interlock- Trip Lug Kit (3 per kit) Front Mounted, NO OR NC. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 64

65 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/3 & Later) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) LR0 (Supply) 7 70 LR0 (Return) 7 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code 4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Link 70C 7 Link 70C 7A Spacer Contactor 7 Contactor MMP30/40 & M30/40 Link Detail 7.5 HP Motors- Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/30V 5, 0 HP Motors- 0 HP Motors- 5 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 7.5 HP Motors- 08/30/ 0, 5 HP Motors- Phase Barrier 70A Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 65

66 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/3 & Later) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30,40 Motor Protector A Phase Barrier B Contact- Auxiliary C Link LR0, 0 Line Reactor- see page after Inverters 7 M30B, I M40B, I Contactor 9A A A A A A A A A Spacer Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 66

67 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/3 & Earlier) Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams 7 LR0 (Supply) LR0 (Return) MMP30 (Supply) MMP40 (Return) 7 M30B/M30I (Supply) M40B/M40I (Return) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 3, 5, 8) Two boxes installed if Code 4= 5 Bypass Controls Detail MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n , 48, MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 67

68 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/3 & Earlier) Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30 Motor Control MMP LR0,0 Line Reactor- see page after inverters 7 M30B,I Contactor M40B,I Contact- Auxiliary Link Interlock- Trip Lug Kit (3 per kit) Front Mounted, NO OR NC. Also requires 3 ring terminals. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 68

69 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/3 & Later) Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) LR0 (Supply) 7 70 LR0 (Return) 7 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code 4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Front Mtd. Aux. Contact 70B MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Link 70C Link 70C 7 7 Contactor Contactor MMP30/40 & M30/40 Link Detail 30 HP Motors- 460/ 40 HP Motors- Contactors 7 MMP30/40 & M30/40 Link Detail 30 HP Motors- 08/30V 40 HP Motors- 50, 60 HP Motors- 460/ 75 HP Motors- Overload 78 Interlock 79 MMP30/40 & M30/40 Link Detail 40, 50, 60 HP Motors- 08/30V 75 HP Motors- 08/30/ Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 69

70 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/3 & Later) Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see next page 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30 Motor Protector MMP A A A A A A A Phase Barrier B Contact- Auxiliary C Link LR0,0 Line Reactor- see page after Inverters 7 M30B,I Contactor 5A M40B,I Contactor 85A A A A A A A A OL30 Overload 50-50A OL40 Overload 50-00A A Mechanical Interlink Mechanical Interlink N/S CB30,40 Circuit Breaker 5A Circuit Breaker 50A N/S= Not Shown on Diagram. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 70

71 Section F- Supply Air Section Inverters Code 5= R (Model VTAC9) 08/30V Motor Horsepower Part Number Note that 60 & 75 HP motors are not available in 08/30V (Code =, 9). 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

72 Section F- Supply Air Section Inverters, Continued Code 5= A (Model ACH550) Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number The replacement VFD Keypad Display is p/n Note that 60 & 75 HP motors are not available in 08/30V (Code =, 9). Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

73 Section F- Supply Air Section Inverters, Continued Code 5= G (Model 3500) Motor Horsepower Part Number V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V Motor Horsepower Part Number Note that 60 & 75 HP motors are not available in 08/30V (Code =, 9). 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 73

74 Section F- Supply Air Section Inverters, Continued Code 5= S, Q (MD, MD3, MD6) 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number , , , , , Early production units (late 00 & earlier) shipped with ATV VFDs. All ATV drives have been replaced with ATV drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV Remote Keypad is p/n The ATV Lonworks communication card is p/n The ATV Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The ATV Lonworks communication card is p/n All other ATV communication cards are integral to the VFD and are not available separately. Note that since the original ATV drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV part fails, the entire drive must be replaced. Also, 60 & 75 HP motors are not available in 08/30V (Code =, 9). MD3 Remote Keypad p/n is MD6 Remote Keypad p/n is plus Mount p/n For units with an MD3 Inverter and Motor under 5 HP a Line Reactor will be installed regardless of whether one is specified in Code 7 (see nomenclature page). See one page after next for Line Reactor part numbers. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 74

75 Section F- Supply Air Section Inverters, Continued Code 5= B (MD4, MD5) 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number The replacement VFD Keypad Display is p/n Note that 60 & 75 HP motors are not available in 08/30V (Code =, 9). 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 75

76 Section F- Supply Air Section Line Reactors 08V/30V Motor Horsepower V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V Part Number Line Reactors are used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8; except for MD3 Inverters (Code 5= S, Q ) - 0 HP. These will always have a Line Reactor installed regardless of Code 7. These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 76

77 Section F- Supply Air Section Section Mounted Controls PC7, HL, LT0, S0, REC0, UV Lights PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket 9 Pressure Control- PC7 0 Pneumatic Fitting In mid 0 the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 9043 for proper installation as old and new parts are NOT interchangeable. The Switch only is p/n , the Pneumatic Fitting is p/n 9044, and the Support Bracket is p/n HL- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 67 T-stat- HL Hi Limit LT0- Supply Fan Light/S0- Supply Fan Light Switch/ REC0- Supple Fan Light Receptacle Code 49= B, E Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC UV Lights Code 7= C thru C8 AND Y thru Y8 Ref. Part Part Qty. No. Description Number 98 Light Fixture- 8 Bulb Light Fixture- 4 Bulb Light Fixture- 36 Bulb Bulb/Lamp, UV Bulb/Lamp, UV Bulb/Lamp, UV Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 77

78 Section F- Supply Air Section Section Mounted Controls MAT, EFT, SAT, DAT, OAT, SD 5 MAT/EFT Mixed Air Temperature Sensor- MAT OR Entering Fan Temperature Sensor- EFT Ref. Part Part Qty. No. Description Number MicroTech II Code = *D, *S 5 Temp. Sensor- MAT Temp. Sensor- EFT MicroTech III Code = *E, *F, *W 5 Temp. Sensor- MAT Temp. Sensor- EFT Supply Air Temperature Sensor- SAT OR Discharge Air Temperature Sensor- DAT 8 SAT/DAT Ref. Part Part Qty. No. Description Number MicroTech II Code = *D, *S 5 Temp. Sensor- SAT Temp. Sensor- DAT MicroTech III Code = *E, *F, *W 5 Temp. Sensor- SAT Temp. Sensor- DAT Outdoor Air Temperature Sensor- OAT OAT 7 Ref. Part Part Qty. No. Description Number MicroTech II Code = *D, *S 5 Temp. Sensor- OAT MicroTech III Code = *E, *F, *W 5 Temp. Sensor- OAT SD- Supply Air Smoke Detector Code 6=, 3 Smoke Detector Detail 50 Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD Sensing Tube Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 78

79 Section F- Supply Air Section Section Mounted Controls SCB- Split Junction Box (Code 05= F)- TB5, TB7, TB8, PB0, PB9, PB0, PB9 TB8 TB7 TB5 PB 9 PB 0 PB 9 PB 0 Motor HP , Sch. Part Part Sym. Description Number Terminal Blocks TB5 Terminal Block- SCB TB7 Terminal Block- SCB TB8 Terminal Block- SCB PB0 Power Block- Supply Fan 95A, 600V, 3P A, 600V, 3P PB9 Power Block- Supply Fan 95A, 600V, 3P PB0 Power Block- Return Fan 95A, 600V, 3P PB9 Power Block- Return Fan 95A, 600V, 3P Only used when unit has a Supply Fan Inverter or Power Exhaust Damper. 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 79

80 Section G- Blow-Thru Heat Section Notes Primary Codes that pertain: 04, 34 Additional Codes that pertain: 06, 07, 09,, 3 This section is divided into four subsections:. Blank Compartment;. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat. Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section s characteristics. If Code 04= Y, and Code 34= YYYYYY there is no section. If Code 04= Y and Code 34= BBBBBB, then there is a 48 Blank Access Section installed. Otherwise, see the Unit Code Index in the nomenclature section for specific heat section definitions. Code 06 determines the insulation and liners and will affect the Top Panel, Uprights, and Door Assembly part numbers. For sheet metal components that make up the BlowThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is UL approved (USA) or CSA approved (Canada). Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls. Code determines the Control type and will affect the Gas Heat Actuator. Code 3 is the Supply Fan size, and affects the heat section s Diffusers. Section Mounted Controls Option : Blank Compartment Code 34= BBBBBB and Code 04= Y Diffuser LT- BT Heat Section Light/S- BT Heat Section Light Switch/ REC- BT Heat Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Ref. Part Part Qty. No. Description Number Diffuser 33 Supply Fan Code 3= 33** Supply Fan Code 3= 36** Supply Fan Code 3= 40** Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 80

81 Section G- Blow-Thru Heat Section Option : Hot Water OR Steam Coil Heat, Mixing Valves & Actuator VM Code 34 first 3 digits= S, S, S3, S4, W, W Diffuser Coil Location Mixing Valve Detail (HW shown) Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number Steam Heat Coil- Bottom S*** 5JA060H Steam Heat Coil- Bottom S*** 5JA0H Steam Heat Coil- Bottom S3*** 5JA060C Steam Heat Coil- Bottom S4*** 5JA0C Hot Water Heat Coil- Bottom W*** 5WH090H Hot Water Heat Coil- Bottom W*** 5WS090C Steam Heat Coil- Top S*** 5JA060H Steam Heat Coil- Top S*** 5JA0H Steam Heat Coil- Top S3*** 5JA060C Steam Heat Coil- Top S4*** 5JA0C Hot Water Heat Coil- Top W*** 5WH090H Hot Water Heat Coil- Top W*** 5WS090C N/S FS Freezestat ALL ALL ALL Diffuser- 7 Supply Fan Diffuser- 30 Supply Fan Diffuser- 33 Supply Fan N/S Valve, Way Steam Heat w/ Act..5 S**EE 5JA All S**FE 5JA All S**GE 5JA All S**HE 5JA All VM Actuator- 4V, Valve W****E All All Actuator- 4V, Valve W****E All All Valve, 3 Way HW w/ Actuator.5 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All W**H3E 5WH, 5WS All W**J3E 5WH, 5WS All N/S= Not shown on diagram. Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

82 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit= E Heaters, Hi Limit Cutouts, Diffusers 5 Air Flow 7 7A 6 Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 5 Heater Assy.- Top 80 E Heater Assy.- Top 80 E Heater Assy.- Top 80 E N/A Heater Assy.- Top 00 E Heater Assy.- Top 00 E Heater Assy.- Top 00 E00 00 N/A Heater Assy.- Top 0 E Heater Assy.- Top 0 E Heater Assy.- Top 0 E0 0 N/A Heater Assy.- Top 60 E Heater Assy.- Top 60 E Heater Assy.- Top 60 E60 60 N/A Heater Assy.- Top 00 E Heater Assy.- Top 00 E Heater Assy.- Top 00 E00 0 N/A Heater Assy.- Top 40 E Heater Assy.- Top 40 E Heater Assy.- Top 40 E40 0 N/A Heater Assy.- Top 80 E Heater Assy.- Top 80 E Heater Assy.- Top 80 E80 60 N/A Heater Assy.- Top 30 E Heater Assy.- Top 30 E Heater Assy.- Top 30 E30 60 N/A N/A= Not Applicable. Units ETL/MEA approval (Code 07= EY) or no approval (Code 07= YY). Heater Assy. includes Hi Limit auto and manual reset switches. Units CSA approval (Code 07= CY). Heater Assy. includes Hi Limit auto reset switches. 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

83 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit= E Heaters, Hi Limit Cutouts, Diffusers, Continued Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 6 Blank Assy.- Bottom E/ Heater Assy.- Bottom 00 E Heater Assy.- Bottom 00 E Heater Assy.- Bottom 00 E00 80 N/A Heater Assy.- Bottom 40 E Heater Assy.- Bottom 40 E Heater Assy.- Bottom 40 E40 0 N/A Heater Assy.- Bottom 80 E Heater Assy.- Bottom 80 E Heater Assy.- Bottom 80 E80 0 N/A Heater Assy.- Bottom 30 E Heater Assy.- Bottom 30 E Heater Assy.- Bottom 30 E30 60 N/A HL-0 Hi Limit- Manual Cutout All All All N/A 7A HL3-50 Hi Limit- Auto Cutout All All All Diffuser All All All N/A= Not Applicable. Units ETL/MEA approval (Code 07= EY) or no approval (Code 07= YY). Heater Assy. includes Hi Limit auto and manual reset switches. Units CSA approval (Code 07= CY). Heater Assy. includes Hi Limit auto reset switches. 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 83

84 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit = E Electric Heat Control Box: (03/3 & Earlier) FB33 FB3 FB3 M33 M3 M3 FB33 FB3FB36FB3FB35 FB33 FB3 FB3 FB44 FB34 M33 M3 M36 M3 M35 M33 M3 M3 M44 M34 FB34 H S 3 FB34 H S 3 FB43 FB4 FB4 H S 3 M34 08/30V 0KW- 0KW T B M34 460/ 0KW- 60KW T B M43 M4 M4 460/ 00KW- 30KW T B PB3 PB3 PB3 DS3 or PB3 DS3 or PB3 DS3 or PB3 DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Amps Switch Handle Shaft Ground Lug DS3 Disconnect Switch 00 Amp Disconnect Switch 50 Amp Disconnect Switch 50 Amp Disconnect Switch 400 Amp Disconnect Switch 600 Amp Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS3 size. Includes Mechanism (except 600A switch, see footnote 4). 3 The original M frame Disconnect is obsolete and replaced with a P frame Switch. Due to dimensional differences minor field modifications may be required for proper installation. 4 Handle only p/n ; Mechanism only p/n ; Shaft p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 84

85 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit = E Electric Heat Control Box: (03/3 & Earlier) 0-0KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block 4 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V HS3 Switch TB Terminal Block M3 Contactor Contactor M3 Contactor Contactor M33 Contactor Contactor M34 Contactor Contactor M35 Contactor M36 Contactor FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block Part number is for one section. The number of sections used is determined by the options installed. See chart on previous page. 3 Cover PB3 used with 600A DS3= p/n Not used when PB3 Power Block connection is present. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 85

86 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit= E Electric Heat Control Box: (03/3 & Earlier) 0-0KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number F3 Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V F3 Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse F33 Fuse Fuse Fuse Fuse Fuse Fuse Fuse F34 Fuse Fuse Fuse Fuse Fuse F35 Fuse F36 Fuse Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 86

87 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit= E Electric Heat Control Box: (03/3 & Earlier) 60-30KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block PB3 Power Block 4 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch HS3 Switch TB Terminal Block M3 Contactor M3 Contactor M33 Contactor Contactor M34 Contactor Contactor M4 Contactor Contactor M4 Contactor Contactor M43 Contactor Contactor M44 Contactor Contactor FB3 Fuse Block FB3 Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB43 Fuse Block Fuse Block FB44 Fuse Block Fuse Block Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Cover- PB3 used with 600A DS3 is p/n Not used when PB3 Power Block connection is present. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 87

88 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit= E Electric Heat Control Box: (03/3 & Earlier) 60-30KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number F3 Fuse Fuse F3 Fuse Fuse F33 Fuse Fuse Fuse Fuse F34 Fuse Fuse Fuse Fuse F4 Fuse Fuse Fuse Fuse F4 Fuse Fuse Fuse Fuse F43 Fuse Fuse Fuse Fuse F44 Fuse Fuse Fuse Fuse Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 88

89 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit = E Electric Heat Control Box: (04/3 & Later) FB33 FB37 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB33 FB3 FB3 M33 M37 M3 M36 M3 M35 FB34 FB38 H S 3 M33 M3 M3 FB34 H S 3 M33 FB43 M3 FB4 M3 FB4 H S 3 T B M34 T B M43 M4 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 08/30V 0KW- 60KW DS3 or PB3 460/ 0KW- 60KW DS3 or PB3 460/ 00KW- 40KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 00A Not Used N/A Disconnect Switch- 50A Disconnect Switch- 50A Disconnect Switch- 400A Disconnect Switch- 600A Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. This Shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This Shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 89

90 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit = E Electric Heat Control Box: (04/3 & Later) 0-0KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block 75A Power Block 40A PB3 Power Block 3 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V HS3 Switch TB Terminal Block M3 Contactor 40A Contactor A M3 Contactor 40A Contactor A M33 Contactor 40A Contactor A M34 Contactor 40A Contactor A M35 Contactor 40A M36 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. See the chart on the previous page. 3 Not used when PB3 Power Block connection is present. 4 Cover- PB3 used with 600A DS3 is p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 90

91 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit = E Electric Heat Control Box: (04/3 & Later) 0-0KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

92 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit= E Electric Heat Control Box: (04/3 & Later) 60-30KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block PB3 Power Block 4 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch HS3 Switch TB Terminal Block M3 Contactor 40A M3 Contactor 40A M33 Contactor 40A Contactor A M34 Contactor 40A Contactor A M4 Contactor 40A Contactor A M4 Contactor 40A Contactor A M43 Contactor 40A Contactor A M44 Contactor 40A Contactor A FB3 Fuse Block FB3 Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB43 Fuse Block Fuse Block FB44 Fuse Block Fuse Block Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Cover- PB3 used with 600A DS3 is p/n Not used when PB3 Power Block connection is present. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

93 Section G- Blow-Thru Heat Section Option 3: Electric Heat Code 34 first digit= E Electric Heat Control Box: (04/3 & Later) 60-30KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number F3 Fuse Fuse F3 Fuse Fuse F33 Fuse Fuse Fuse Fuse F34 Fuse Fuse Fuse Fuse F4 Fuse Fuse Fuse Fuse F4 Fuse Fuse Fuse Fuse F43 Fuse Fuse Fuse Fuse F44 Fuse Fuse Fuse Fuse Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 93

94 Section G- Blow-Thru Heat Section Option 4- Gas Heat Code 04= A Vestibules, Heat Exchangers and Primary Components 500, 640, 650, 790, 800, 000, 00, 400 MBH Code 34= 050**, 064**, 065**, 079**, 080**, 00**, 0**, 40** Heat Exchanger 300 Burner 3 Burner Control Box 4 Gas Train 5 Ref. Part 500/ / /000 00/400 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger, St. Stl Vestibule Vestibule N/S Turbulator N/S= Not shown on diagram. Note that other components may be also be replaced when replacing a Heat Exchanger. If this is the case, contact Daikin Applied with model and serial number information so that all required parts can be identified. Quantity varies depending upon the size of the Heat Exchanger. For 500/640 MBH order 9 pc.; for 650/790 MBH order pc.; for 800/000 MBH order 5 pc.; for 00/400 MBH order pc. Note that Turbulators are NOT furnished with the Heat Exchanger Kit. 3 Parts detail follows this section. 4 Parts detail follows Burner section. 5 Parts detail follows Burner Control Box section. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 94

95 Section G- Blow-Thru Heat Section Option 4- Gas Heat Code 04= A Vestibules, Heat Exchangers and Primary Components 500, 000 MBH Code 34= 50***, 00*** Heat Exchanger Burner Burner Control Box Gas Train 3 Ref. Part 500/000 Qty. No. Description MBH Heat Exchanger- Stainless Steel Secondary Code 34= ***S** N/S Turbulator N/S= Not shown on diagram. Parts detail follows this section. Parts detail follows Burner section. 3 Parts detail follows Burner Control Box section. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 95

96 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Diagrams Burner Control Box MBH burners Housing Detail: MBH Burners Pilot Valve/ Pressure Regulator Assy. Detail Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 96

97 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Components Burner Approval Code Qty. Ref. Part Code 07= EU, EF, EI Code 07= CC, CD No. Description UL/ETL CSA 0 Burner Housing MBH Furnace MBH Furnace Scroll MBH Furnace MBH Furnace Wheel-.5 bore MBH Furnace MBH Furnace MBH Furnace Motor MBH Furnace MBH Furnace MBH Furnace Gun Assembly 500 MBH Furnace , 650 MBH Furnace , 800 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube MBH Furnace MBH Furnace , 400 MBH Furnace , 000 MBH Furnace Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 97

98 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Components, Continued Burner Approval Code Qty. Ref. Part Code 07= EU, EF, EI Code 07= CC, CD No. Description UL/ETL CSA 0 Pilot Mixer MBH Furnace MBH Furnace Pilot Assembly Damper Assembly MBH Furnace MBH Furnace Blast Tube Gasket MBH Furnace , 400 MBH Furnace , 000 MBH Furnace Right Side Damper 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace , 000 MBH Furnace Left Side Damper 500, 640 MBH Furnace MBH Furnace MBH Furnace MBH Furnace , 000 MBH Furnace Slide Damper 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Blower Gasket Burner Cover MBH Furnace MBH Furnace Ignition Assembly MBH Furnace MBH Furnace Glass Cover Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 98

99 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Components, Continued Burner Approval Code Qty. Ref. Part Code 07= EU, EF, EI Code 07= CC, CD No. Description UL/ETL CSA Glass Cover Support Orifice 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Clip Flange Bearing Air Switch Tube MBH Furnace MBH Furnace Pilot Burner Tube MBH Furnace , 400 MBH Furnace , 000 MBH Furnace Compression Fitting Pilot Tube Torsion Spring Not Used Burner Box Baffle MBH Furnace MBH Furnace Damper, Slide- Top 00 MBH Furnace Not Used 400 MBH Furnace Not Used 500 MBH Furnace Not Used 000 MBH Furnace Not Used 60 Valve- Pressure Regulator Valve- Solenoid Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 99

100 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Diagrams Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail 0 99 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 00

101 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Components Burner Approval Code Qty. Ref. Part Code 07= EU, EF, EI Code 07= CC, CD No. Description UL/ETL CSA 0 Burner Housing MBH Furnace MBH Furnace Scroll 500 thru 800 MBH Furnace MBH Furnace Wheel-.5 bore MBH Furnace MBH Furnace MBH Furnace Motor-.5 HP, 5/60/ MBH Furnace MBH Furnace MBH Furnace Gun Assembly 500 MBH Furnace , 650 MBH Furnace , 800 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube 500, 640 MBH Furnace MBH Furnace , 400 MBH Furnace , 000 MBH Furnace Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

102 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part Code 07= EU, EF, EI Code 07= CC, CD No. Description UL/ETL CSA 0 Orifice Assembly 500 MBH Furnace MBH Furnace MBH Furnace , 800 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Gasket- Blast Tube MBH Furnace MBH Furnace Air Box Assembly MBH Furnace MBH Furnace Plate- Actuator Scale Gasket- Blower Panel- Burner Box Cover MBH Furnace MBH Furnace Ignition Wire Assembly MBH Furnace MBH Furnace Glass Cover- Burner Support- Glass Cover Grommet- Flat Box- Conduit ( MBH only) Motor- Actuator 0V Motor- Actuator 4V Control Arm MBH Furnace MBH Furnace Control Rod MBH Furnace MBH Furnace Crank Arm MBH Furnace MBH Furnace Normally units without controls (Code = YM, YC) use a 0V Actuator and units with controls (Code = *D, *S, *E, *F, *W) use a 4V Actuator. Confirm voltage required before ordering. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

103 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part Code 07= EU, EF, EI Code 07= CC, CD No. Description UL/ETL CSA 30 Extension- Crank Arm Bushing- Control Rod Linkage Plate- Adjustable 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Plate- Profile 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Plate- Slide Damper 500 MBH Furnace , 650 MBH Furnace , 800, 000 MBH Furnace , 400, 500 MBH Furnace MBH Furnace Box- Air MBH Furnace Furnace Gasket- Air Box MBH Furnace Furnace Grommet Bearing- Sleeve Grommet MBH Furnace Furnace Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 03

104 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls: Code 34= ****E*, ****R*, ****S* AND MicroTech II OR No Controls (Code = *D, *S, Y*) Diagram FSG Detail Gas Control Box Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 04

105 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls: Code 34= ****E*, ****R*, ****S* AND MicroTech II OR No Controls (Code = *D, *S, Y*) Components Ref. Sch. Part Furnace MBH: Qty. No. Sym. Description GV Pressure Reg. Assembly Valve Only Solenoid Valve Support Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. UL Units Flame Safeguard T.D. 30 Sec. CSA Units S3 Toggle Switch- 4PST IT Ignition Transformer Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Block- 4 Pole Fitting Bushing R0 Relay- SPDT Code = *D, *S R0 Relay (Before /0) Code = YM, YC N/S R0A Relay (After /0) Code = YM, YC N/S Relay Socket R3 Relay (Before /0) Code = YM, YC N/S R3A Pilot Relay (After /0, ETL only) Code = YM, YC N/S Mounting Adapter N/S R3B Pilot Relay (After /0) Code = YM, YC N/S Relay Socket M9 Contactor- Motor Not Used R3 Pilot Relay- DPDT Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 05

106 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls: Code 34= ****E*, ****R*, ****S* AND MicroTech III Controls (Code = *E, *F, *W) M9 64 R3B 63 R3A 6 R0A 6 30 IT 3 FLC 3 34 TB S3 Gas Control Box 6 FSG Detail 7 5 FSG See Detail Gas Valve Detail Ref. Sch. Part Furnace MBH: Qty. No. Sym. Description GV Pressure Reg. Assembly Valve Only Solenoid Valve Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. UL Units Flame Safeguard T.D. 30 Sec. CSA Units S3 Toggle Switch- 4PST: S IT Ignition Transformer AS Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Block Terminal Block End Stop Terminal Block End Plate Jumper Terminal R0A Relay- High Amp DPDT/0V R3A Relay- High Amp DPDT/0V R3B Relay- Low Amp DPDT/0V M9 Contactor- Motor DPDT/0V Not Used Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 06

107 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U* AND MicroTech II OR No Controls (Code = *D, *S, Y*) Diagram TB 34 TD0 R FSG Detail R R R See Detail MBH Panel Detail Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 07

108 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U* AND MicroTech II OR No Controls (Code = *D, *S, Y*) Components Ref. Sch. Part Furnace MBH Qty. No. Sym. Description Support Support Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS Switch- Limit TB Terminal Block Fitting Bushing Bushing R0 Relay Code = *D, *S R0 Relay (Before /0) Code = YC R0 Relay (Before /0) Code = YM N/S R0A Relay (After /0) N/S Relay Socket N/S R3A Pilot Relay (After /0, ETL only) N/S Mounting Adapter N/S R3B Pilot Relay (After /0) N/S Relay Socket M9 Contactor- Motor Not Used R3 Relay- 0V/DPDT R Relay- 0V/DPDT (Before /0) N/S R Relay- 0V/DPDT (After /0) N/S Mounting adapter R Relay- 0VSPST TD0 Relay- Time Delay 0.0 Sec Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 08

109 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U* AND MicroTech III Controls (Code = *E, *F, *W) R3B M IT R3A 64 R 63 3 FLC R0B 6 R0A 6 34 TB AS 3 LS LS 5 33 LS_ S3 FSG Detail 5 Ref. Sch. Part Furnace MBH Qty. No. Sym. Description Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper R0A Relay- High Amp DPDT/0V R0B Relay- Low Amp DPDT/0V R Relay- Low Amp DPDT/0V R3A Relay- High Amp DPDT/0V Not Used R3B Relay- Low Amp DPDT/0V Not Used M9 Relay- High Amp DPDT/0V Not Used Quantity varies. Determine quantity required BEFORE ordering, or contact Daikin Applied with model and serial number information so that the correct number of parts can be supplied. Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 09

110 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Inlet Units without Pressure Regulator Valve: Code 34= ****E* MBH 000 MBH Ref. Part Part No. Description Number Qty. 05 Shutoff Valve MBH Gas Valve 500 MBH MBH MBH MBH Units with Pressure Regulator Valve: Code 34= ****R*, ****S* , 640, 650, 800 MBH Furnaces 000 MBH Furnaces 00, 400 MBH Furnaces 500 MBH Furnaces 000 MBH Furnaces Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 05 Shutoff Valve Pressure Regulator 500 MBH , 650 MBH , 800 MBH MBH MBH MBH MBH MBH Gas Valve 500 MBH MBH MBH Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

111 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Inlet CSA Units Code 07= CC, CD Units without Pressure Regulator Valve: Code 34= ****H* 6 Combination Valve Detail Back Wall of Vestibule Ref. Part Part Qty. No. Description Number 6 Gas Valve 500 MBH MBH MBH MBH Combination Valve Units with Pressure Regulator Valve: Code 34= ****T*, ****U* 3 Back Wall of Vestibule 6 9 Combination Valve Detail Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 6 Shutoff Valve 500 MBH MBH MBH Pressure Regulator 500 MBH , 650 MBH , 800 MBH MBH MBH MBH MBH MBH Valve- Combination Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

112 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Inlet UL Units Code 07= EU Units without Pressure Regulator Valve: Code 34= ****H* 6 Ref. Part Part Qty. No. Description Number 6 Gas Valve 400/500 MBH MBH MBH MBH Units with Pressure Regulator Valve: Code 34= ****T*, ****U* 3 6 Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 6 Shutoff Valve 500 MBH MBH MBH Pressure Regulator 500 MBH , 650 MBH , 800 MBH MBH MBH MBH MBH MBH Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

113 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Controls: GV, GV3 UL Units Code 07= EU, YU MBH Furnaces UL Approved (Code 07= EU, YU) 53 GV 56 GV Gas Controls: MBH Furnace UL Approved Ref. Part Part Qty. No. Description Number 48 Gas Valve- GV, GV3 500 MBH MBH MBH MBH Pressure Regulator 500 MBH MBH MBH MBH Junction Box Junction Box Cover Gas Pipe Modulating Burner 500 MBH MBH , 790 MBH , 000 MBH , 400 MBH MBH MBH Single Stage Burner 500 MBH MBH , 790 MBH MBH MBH , 400 MBH MBH MBH Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

114 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Controls: GV, VM CSA Units Code 07= CC, CD Gas Controls: MBH Furnace CSA Approved MBH Furnaces CSA Approved (Code 07= CC, CD) GV 6 Ref. Part Part Qty. No. Description Number 48 Gas Valve Body- GV 500 MBH MBH MBH Actuator- VM Pressure Regulator 500 MBH MBH MBH MBH Gas Pipe Modulating Burner 500 MBH MBH , 790 MBH , 000 MBH , 400 MBH MBH MBH Single Stage Burner 500 MBH MBH , 790 MBH , 000 MBH , 400 MBH MBH MBH Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

115 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Controls: GV, GV4, GV5, GV6, GV7, GV8 UL Units Code 07= EU, YU MBH Furnaces UL (Code 07= EU, YU) MBH Furnaces UL (Code 07= EU, YU) 00 MBH Furnaces UL (Code 07= EU, YU) 54 GV4 GV GV5 GV4 54 GV GV GV5 GV4 54 GV , 500 MBH Furnaces UL (Code 07= EU, YU) 54 GV7 GV GV5 54 GV4 GV 000 MBH Furnaces UL (Code 07= EU, YU) 54 GV GV7 GV6 54 GV5 GV GV 54 Ref. Part Part Qty. No. Description Number 54 Gas Valve- GV, GV MBH Gas Valve- GV, GV4, GV MBH Gas Valve- GV, GV4, GV5, GV6 00 MBH Gas Valve- GV, GV4, GV5, GV6, GV7 400, 500 MBH Gas Valve- GV, GV4, GV5, GV6, GV7, GV8 000 MBH Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

116 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Controls: GV, GV4, GV5, GV6, GV7, GV8, GV9, VM CSA Units Code 07= CC, CD MBH Furnaces CSA (Code 07= CC, CD) MBH Furnaces CSA (Code 07= CC, CD) 00 MBH Furnaces CSA (Code 07= CC, CD) 47 GV5 54 GV4 54 GV GV6 54 GV5 GV4 54 GV GV7 54 GV6 GV GV5 GV , 500 MBH Furnaces CSA (Code 07= CC, CD) 54 GV GV7 46 GV GV6 GV GV MBH Furnaces CSA (Code 07= CC, CD) GV9 GV GV8 54 GV7 GV6 54 GV5 GV4 54 Ref. Part Furnace Part Qty. No. Description Size Number 46 Gas Valve Body- GV 400, 500 MBH Gas Valve Body- GV MBH Gas Valve Body- GV MBH Actuator- VM Gas Valve- GV4, GV MBH Gas Valve- GV4,GV5,GV MBH Gas Valve- GV4,GV5,GV6,GV7 00 MBH Gas Valve- GV4,GV5,GV6,GV7,GV8 400, 500 MBH Gas Valve- GV4,GV5,GV6,GV7,GV8,GV9 000 MBH Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

117 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Outlet 500, 640 MBH Actuator & Linkage- See next page MBH Modulating Burners Code 34= ****E*, ****R*, ****S* Ref. Part Part Qty. No. Description Number 75 Pipe w/ Valve Mount 500 MBH MBH , 400 MBH , 000 MBH Butterfly Valve 500 MBH MBH , 000 MBH Shutoff Valve 500 MBH MBH MBH UL MBH CSA MBH MBH Actuator & Linkage- See next page , 640 MBH Hi Turn Down Burners Code 34= ****H*, ****T*, ****U* 650, 000 MBH MBH Ref. Part Part Qty. No. Description Number 75 Gas Valve 500 MBH MBH MBH MBH Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

118 Section G- Blow-Thru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Damper Linkage Modulating Burners w/ VM Actuator Code 34= ****E*, ****R*, ****S* 97 Burner Box 95 Butterfly Valve (see previous page) 97 Burner Box 95 Butterfly Valve (see previous page) VM Actuator Switch Kit Transformer CSA Actuator Detail UL Units CSA Units Gas Train Linkage: Modulating Burner (Code 34= ****E*, ****R*, ****S*) Ref. Part Furnace MBH Qty. No. Description , , Actuator Motor- VM Units w/ MicroTech Controls UL Units CSA Units Units w/ No Temp. Ctl. Code = YC UL Units CSA Units Crank Arm Ball Joint Linkage Arm Crank Arm Extension- Arm CSA Units Only Air Damper Lever Arm Not Used 3 Gas Valve Arm Assembly part number. Motor only is p/n 3050, and Interface Kit only is p/n Assembly part number. Motor only is p/n 04770, and Switch Kit only is p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

119 Section G- Blow-Thru Heat Section Option 4- Gas Heat w/ 30 MBH thru 000 MBH Furnace Code 04= A & Code 34= 050***,064***,065***,079***,080***, 00***, 0***, 40*** Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly 500, 640 MBH , 790 MBH , 000 MBH , 400 MBH Inspection Door Back- Flue Box 500, 640 MBH , 790 MBH , 000 MBH , 400 MBH Angle- Flue Box 500, 640 MBH , 790 MBH , 000 MBH , 400 MBH Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket Hinge Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

120 Section G- Blow-Thru Heat Section Option 4- Gas Heat w/ 500 MBH and 000 MBH Furnace Code 04= A & Code 34= 50***, 00*** Cabinet Doors, Gasketing, Hardware, & Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly Inspection Door Back- Flue Box Angle- Flue Box Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

121 Section H- Blow-Thru Heat Blank Access Section OR Sound Attenuator Notes Primary Codes that pertain: 38, 34 Additional Codes that pertain: 06 Code 38 determines all of the section characteristics. If Code 38= Y, there is no section. If Code 38= B, F there is a 48 BlowThru Blank section; if Code 38= E there is a 4 blank section. If Code 38= G, H, there is a straight Attenuator. If Code 38= K, L there is a straight Attenuator with Tedlar coating. If Code 38= J there is an Elbow Attenuator. If Code 38= M there is an Elbow Attenuator with Tedlar coating. Code 34 determines the BlowThru Heat Section (Section G). There has to be a Section G in order for there to be a Section H, therefore Code 34 cannot= YYYYYY. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank compartment, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section I. Sound Attenuator 00 Sound Attenuator Ref. Part Code Part Qty. No. Description 38= Number 00 Sound Attenuator 36 No Coating G w/ Tedlar Coating K No Coating H w/ Tedlar Coating L Air Flow Section Mounted Controls LT9, REC9, S9- Section Mounted Light LT9- BT Access Section Light/S9- BT Access Section Light Switch/REC9- BT Access Section Receptacle. Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

122 Section I- Blow-Thru Cooling Section Notes AND Access Door Latching Assemblies, Key, & Lock Primary Codes that pertain: 03, 35, 36 Additional Codes that pertain: 06 Code 03 determines the cooling coil size. If Code 03= S there is a small face area coil, and if Code 03= L it is a large face area coil. Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling only unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 48 section. If the first three digits of Code 35= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P, Y in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T, the first three digits of Code 35 must equal DYY. Code 36 determines the Blow-Thru Cooling Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blow-Thru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. NOTE: See Section D for all parts used in Section I. Although the section location is different within the unit configuration, the components are identical. Access Door Latching Assemblies, Key, & Lock (All Sections) Ref. Part Part Qty. No. Description Number 0 Door Latching Assy.- LH, 97 Section 4 var. 0 Door Latching Assy.- RH, 97 Section 4 var. N/S Access Door Key var. N/S Access Door Lock 0370 var. N/S= Not Shown on diagram. These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. 0 0 Door Latching Assy. Left Hand Door Latching Assy. Right Hand Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

123 Section J- Final Filter Section Notes Primary Codes that pertain: 39 Additional Codes that pertain: 04, 34, 33 (Mid 0 & Later) Code 39 determines all of the section characteristics. If Code 39= A, J, B, K, E, L, F, M, G, N, H there are Filters; if Code 39= C, D, Q, R, S, T then there is a blank compartment. If Code 39= Y, there is no section. Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts. Code 33 (Mid 0 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description. Door Hardware and Gasketing Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing N/S Door Catch N/S Gasket- Horizontal N/S Gasket- Vertical N/S= Not Shown on diagram. If the unit is split at the fan and heat sections (Code 05= F), use p/n Section Mounted Controls HL3 Gas Hi Limit Control: Code 04= A AND Code 39= DOES NOT= Y PC6 Clogged Filter Control: Code 39= DOES NOT= Y, C, Q, D, R, S, T Gas Hi Limit Control Clogged Filter Control 387 Unit Air Flow Control HL3 Gas Heat Hi-Limit (Firestat) Control PC6 Clogged Filter Pressure Supplied with PC6 Harness from Main/ Split Box Unit Base Ref. Part Part Qty. No. Description Number 386 Stat Support HL3 Firestat Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

124 Section J- Final Filter Section Filters Flat Filter Rack- Code 39= A, E, J, G, N 4A 4 5A 5 Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 4 x 4 x High Heat A, E A, J Filter- 95% Eff- Cartridge, 4 x 4 x Standard S, W A, J Filter- 95% Eff- Cartridge w/ Intersept, 4 x 4 x ALL ALL E, L Filter- 95% Eff- HEPA Cartridge, 4 x 4 x ALL ALL G, N 4A Gasket- Filter High Heat A, E ALL Gasket- Filter Standard S, W ALL Filter- 95% Eff- Cartridge, x 4 x High Heat A, E A, J Filter- 95% Eff- Cartridge, x 4 x Standard S, W A, J Filter- 95% Eff- Cartridge w/ Intersept, x 4 x ALL ALL E, L 4 Filter- 95% Eff- HEPA Cartridge, x 4 x ALL ALL G, N 4 5A Gasket- Filter High Heat A, E ALL Gasket- Filter Standard S, W ALL Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

125 Section J- Final Filter Section Filters, Continued Staggered Filter Rack- Code 39= B, F, K, M, W 4 4A 5 5A 4 4A Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 4 x 4 x High Heat A, E B, K Filter- 95% Eff- Cartridge, 4 x 4 x Standard S, W B, K Filter- 95% Eff- Cartridge w/ Intersept, 4 x 4 x ALL ALL F, M 6 Filter- 95% Eff- Cartridge, 4 x 4 x ALL ALL W 6 4A Gasket- Filter High Heat A, E B, K Gasket- Filter ALL ALL W 6 Gasket- Filter Standard S, W B Filter- 95% Eff- Cartridge, x 4 x High Heat A, E B, K Filter- 95% Eff- Cartridge, x 4 x Standard S, W B, K Filter- 95% Eff- Cartridge w/ Intersept, x 4 x ALL ALL F, M 6 Filter- 95% Eff- Cartridge, 4 x 4 x ALL ALL W 6 5A Gasket- Filter High Heat A, E B, K Gasket- Filter Standard S, W B, K Gasket- Filter ALL ALL W 6 Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

126 Section K- Discharge Plenum Section- RPS, RFS Notes Primary Codes that pertain: 40 Additional Codes that pertain: 06,, 6, 34, 35, 36, 38, 39, 4. Code 40 determines the discharge direction. RPS/RFS units may have bottom discharge (Code BE, BY) OR side discharge (Code LY, RY, SY). RFS units may also have front discharge (Code FY). VAV damper option is Code *E. This section does not pertain to the RDT or the RCS. Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section I. Code, Disconnect Switch option, influences Access Door part numbers. Code 6 determines Smoke Detectors. If Code 6=, 3 there is a Supply Air Smoke Detector (SD). For RPS and RFS units with heat the SD is in Section K. For RDT units, or RPS/RFS Draw-Thru cooling only units (units with no separate Discharge Plenum section) SD is in the Supply Air section (Section F). Codes 34-39, the Blow-Thru/Final Filter section codes, and Code 4, the special Blank Compartment code, pertain to some of the final assembly part numbers. If there is no Blow-Thru final section then the Discharge Plenum is attached directly to the Supply Air Section and some of the final assembly part numbers are different than they are if the Blow-Thru section is present. If Code 4= Y (no Blank Access Compartment), then the Discharge Plenum end panels are painted. If the Blank Compartment is present then the end panels are unpainted. Note: The RPS and RFS Main Control Box is located in the Discharge Plenum Section however, Main Control Box components are listed in Section N. OAT 7 Section Mounted Controls OAT, DAT, SD DAT 8 Discharge Air Temperature Sensor- DAT & Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7, 8 Temp. Sensor, (MTII) DAT/OAT Temp. Sensor, (MTIII) DAT/OAT Smoke Detector Detail 5 50 SD- Supply Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD Sensing Tube Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

127 6 Section K- Discharge Plenum Section Damper Assembly- w/ Actuator ACT Code 40= BE Opening 46 Opening Actuator Detail Opening Size Ref. Part Part No. Description Number Opening Opening Complete Assy. w/ Actuator 3 Motor Mount Not Used Motor Mount Not Used 4 Blade Angle- Linkage Not Used Angle- Linkage Not Used 3 6 Blade- Angle Shaft- Damper Linkage- Shaft Bearing, Flange Actuator- 4V ACT Crank Arm Ball Joint Bearing- Sleeve Support- Actuator Not Used 6 Retainer- Actuator Not Used 7 Bearing- Sleeve Flange Not Used Retainer- Actuator Not Used 8 Bearing- Sleeve Flange Not Used Contact Daikin Applied with model and serial number information so that the correct Damper Assy. can be identified. NOTE: This isolation damper and ACT5 actuator may also be located in Section F (Supply Air). The discharge air opening is in the Supply Air section on RDT units, and RPS or RFS Draw-Thru units with no Blow-Thru heat (applications where Section F is attached directly to the condensing unit, or is the end of the unit). Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

128 Section L- Out-of-Airstream Blank Access Section Notes Codes that pertain: 4 Additional Codes that pertain: 06 If Code 4= Y, there is no Blank Compartment. If Code 4=, there is a 48/4 Blank Compartment with Access Doors and Light (LT0). Code 4=, there is a 48 Blank Compartment with Access Doors and Light (LT0). Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section I. Doors, Gasketing and Hardware Ref. Part Section Size No. Description 48 (C4= ) Qty. 48/4 (C4= ) Qty. N/S Door Assembly N/S Gasket- Horizontal N/S Gasket- Vertical N/S Door Sleeve Bearing N/S Door Catch N/S= Not Shown on diagram. Section Mounted Controls LT0, REC0, S0- Section Mounted Light LT0- Blank Access Section Light/S0- Blank Access Section Light Switch/ REC0- Blank Access Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

129 Section M- Condenser Section Notes Primary Codes that pertain: 09, 43, 47 Additional Codes that pertain:, 7, 8, 4, 45, 68 This section houses the Compressors, Condenser Coils, Condenser Control Box (RCS only), Pressure Controls Box (RPS/RDT only), and Fan Deck. RCS units have a Condenser Control box. RPS and RDT units do not have a control box in the Condenser section (all condenser controls are in the main unit control box). The Compressor high and low Pressure Controls as well as the fan Pressure Controls are always located in this section. RCS units have the Pressure Controls mounted on the control box Manifold (SpeedTrol Inverters and Line Reactors are in the Control Box). RPS and RDT units have the Pressure Controls as well as SpeedTrol Inverters and Line Reactors (if required) in a box mounted where the air handler and condensing unit attach. Code 09, unit voltage, affects Compressor Contactors (located in the Condenser Control Box for RCS units) as well as the Compressor selection. Code 43 determines if the Micro Channel Condenser Coils have Seal Tite Conduits and/or Coil Guards and whether the Coils are coated. Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47= ), or SpeedTrol [Low Ambient operation] (Code 47= ). If Code 47= 3, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. Code determines whether there is a MicroTech Unit Controller present or if the unit is not provided with a factory installed controller. For RCS Standalone Units, when Code = *A, see note below. Code 7 determines whether the RCS control box has Ground Fault and/or Phase Failure capability. Code 8 determines if there is a unit powered Receptacle, and associated components. Code 4 indicates Compressor capacity control. Code 45 determines the way the Compressor is mounted. If Code 45= Y the unit must be an RFS. Code 68 specifies the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at 0 SCCR (Code 68= 0, OR no entry). An entry with any other rating (Eg: Code 68=, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. The Condenser Coil Compartment, and the Compressor Compartment components are different for RPS and RCS units. All other aspects of the section (Fan Deck, Compressors, etc.) are identical. The Condenser Section is integral to the RPS unit, but is not used on the RFS. An RCS unit is a condensing unit only. RCS units can either be used as a Stand Alone Condenser unit, or used in conjunction with an RFS. For information specific to RCS Standalone Units (RCS080-40D units when Code = *A), refer to RPL form Note that an RCS09D is a Standalone only unit and therefore is not included in this document. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

130 Section M- Condenser Section Condenser Fan Deck Assembly D Diagrams: Code 47=, Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail Fan # 3 Fan # Fan # End of Unit 50 Fan # 3 Fan # Fan # End of Unit 55 Fan # 3 Fan # Fan # 080, 085D Fan Deck Detail Fan # 3 Fan # 08D Fan Deck Detail Fan # 4 Fan # 3 Fan # Fan # Fan # 3 Fan # Fan # FAN 4 FAN 5 FAN 4 End of Unit FAN FAN 3 5 Fan # Fan # 4 Fan # 5 Fan # 4 End of Unit Fan # 3 Fan # Fan # 09D Fan Deck Detail Fan # 3 Fan # FAN Fan # 4 FAN FAN 3 6 Fan # 00D Fan Deck Detail (090, 05D shown) Fan # 4 Fan # 3 Fan # Fan # Fan # Fan # Fan # 3 End of Unit Fan # 4 Fan # 3 Fan # Fan # 5 Fan # 4 End of Unit Fan # Fan # 0D Fan Deck Detail Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 Fan # 4 Fan # Fan # 3 090, 05D Fan Deck Detail RPL / Page 30

131 Section M- Condenser Section Condenser Fan Deck Assembly D Components Unit Size Ref. Part Part No. Description Number Condenser Coils Code 43= M* 5 3 x 84 6/3 & Earlier x 84 7/3 thru 5/4 3 x 84 6/4 & Later x 84 9/3 & Earlier x 84 0/3 thru /4 46 x 84 /4 & Later Condenser Coils Code 43= T* 5 46 x Condenser Coils, Coated Code 43= P* 5 3 x 84 7/3 & Earlier x 84 7/3 thru /4 3 x 84 3/4 & Later x 84 9/3 & Earlier x 84 0/3 thru /4 46 x 84 /4 & Later Condenser Coils, Coated Code 43= U* 5 46 x Condenser Coils Code 43= M* 6 3 x 84 6/3 & Earlier x 84 7/3 thru 5/4 3 x 84 6/4 & Later x 84 6/3 & Earlier x 84 7/3 thru 3/4 36 x 84 4/4 & Later Condenser Coils, Coated Code 43= P* 6 3 x 84 7/3 & Earlier x 84 8/3 thru /4 3 x 84 /4 & Later x 84 9/3 & Earlier x 84 0/3 thru /4 36 x 84 /4 & Later Condenser Coils, Coated Code 43= U* 6 36 x Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

132 Section M- Condenser Section Condenser Fan Deck Assembly D Components: Code 47=, Unit Size Ref. Part Part No. Description Number Condenser Fan Motor Code 47=, FanTrol/SpeedTrol 08/30/ FanTrol/SpeedTrol Condenser Fan Deck Code 47=, 55 Panel- Blank Top Panel Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit (RPS/RDT) N/S Vandal Guard Kit (RPS/RDT) N/S Vandal Guard Kit (RCS) N/S= Not shown on Diagram. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications when Code 47= OR. This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

133 Section M- Condenser Section Condenser Fan Deck Assembly 0-40D Diagrams: Code 47=, Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail 30 Fan # 4 Fan # 3 Fan # Fan # End of Unit Fan # 4 Fan # 3 Fan # Fan # End of Unit Fan # 5 Fan # 4 Fan # 3 Fan # Fan # Fan # 4 Fan # 3 Fan # Fan # 0D Fan Deck Detail 0D Fan Deck Detail Fan # 4 Fan # 3 Fan # Fan # 5 Fan # Fan # 5 End of Unit Fan # 4 Fan # 3 Fan # Fan # 5D Fan Deck Detail Fan # Fan # Fan # 5 Fan # 6 Fan # 6 Fan # 5 Fan # 4 Fan # 3 5 (5D shown) End of Unit Fan # 4 Fan # 3 Fan # Fan # 30, 40D Fan Deck Detail Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 33

134 Section M- Condenser Section Condenser Fan Deck Assembly 0-40D Components Unit Size , 40 Ref. Part Part No. Description Number Condenser Coils Code 43= M* 5 3 x 84 6/3 & Earlier x 84 7/3 thru 5/ x 84 6/4 & Later Condenser Coils, Coated Code 43= P* 5 3 x 84 7/3 & Earlier x 84 7/3 thru / x 84 3/4 & Later Condenser Fan Motor Code 47=, FanTrol/SpeedTrol 08/30/ FanTrol/SpeedTrol Condenser Fan Deck Code 47=, 55 Panel- Blank Top Panel Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit (RPS/RDT) N/S Vandal Guard Kit (RCS) N/S= Not shown on Diagram. Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications when Code 47= OR. 3 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 34

135 Section M- Condenser Section Condenser Fan Deck Assembly Quiet Fan Assembly Fan Code 47= 3, 4 Unit Size Ref. Part Part No. Description Number Quiet Fan Assy. 08V V Panel, Blank Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor Mount, and Fan Top Panel are NOT available separately. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 35

136 or Section M- Condenser Section Compressors & Compressor Components Unit Sizes 080 thru 09D: Code 44= R Side View Discharge Tubing 45 Gas Tubing Suction Tubing Circuit # Comp. # Comp. #3 Comp. #5 or or or or Circuit # Comp. # Comp. #4 Comp. #6 Compressor to Compressor Rail Mounting Detail 75 Circuit # or Circuit # Top View 0 Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 30 Compressor Rail to Base Channel Mounting Detail (8 places) Compressor Rail Compressor Mounting Channel 080, Ref. Part Part No. Description Number, Compressors- Circuits # OR Compressors- Circuits # OR Compressors- Circuits # OR Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Sight Glass- Gas Line Junction Box- Compressor Fitting- Rotolock Heater- Crankcase Heater- Crankcase Gasket- Junction Box Rail- Trio Compressor Mounting Spacer Screw Washer Quantities are for unit. Each circuit has equal quantities of each part. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 36 08/30V 08/30V

137 or Section M- Condenser Section Compressors & Compressor Components Side View Discharge Tubing 45 Gas Tubing Suction Tubing Circuit # Comp. # Comp. #3 Comp. #5 or or or or Circuit # Comp. # Comp. #4 Comp. #6 Compressor to Compressor Rail Mounting Detail Unit Size 00, 0D: Code 44= R 75 Circuit # or Circuit # Top View 0 Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 30 Compressor Rail to Base Channel Mounting Detail (8 places) Compressor Rail Compressor Mounting Channel 00, 0 Ref. Part Part No. Description Number Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Sight Glass- Gas Line Fitting- Rotolock Heater- Crankcase Rail- Trio Compressor Mounting Spacer Screw Washer Quantities are for unit. Each circuit has equal quantities of each part. 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 37

138 Section M- Condenser Section Compressors & Compressor Components Unit Size 05, 0D: Code 44= R Side View Top View Discharge Tubing 0 or 45 Circuit # or Circuit # Gas Tubing Suction Tubing Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 75 Circuit # or Circuit # Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 30 Compressor to Compressor Rail Mounting Detail Compressor Rail to Base Channel Mounting Detail (8 places) Compressor Rail Compressor Mounting Channel 05, 0 Ref. Part Part No. Description Number, Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Sight Glass- Gas Line Fitting- Rotolock Heater- Crankcase Rail- Trio Compressor Mounting Spacer Screw Washer Quantities are for unit. Each circuit has equal quantities of each part. 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 38

139 Section M- Condenser Section Compressors & Compressor Components Unit Size 0D Diagrams: Code 44= R Circuit # Circuit # Side View Discharge Tubing Side View Discharge Tubing Gas Tubing Suction Tubing Gas Tubing Suction Tubing Circuit # or Circuit # Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 Circuit # or Circuit # Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 Top View Top View Circuit # or Circuit # Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. # Circuit # or Circuit # Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. # Compressor to Compressor Rail Mounting Detail Compressor to Compressor Rail Mounting Detail Compressor Rail to Base Channel Mounting Detail (8 places) Compressor Rail to Base Channel Mounting Detail ( places) Compressor Rail Compressor Rail Compressor Mounting Channel Compressor Mounting Channel Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 39

140 Section M- Condenser Section Compressors & Compressor Components Unit Size 0D Components: Code 44= R 0 Ref. Part Part No. Description Number, Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Mounting Kit Circuit # Grommet Circuit # Sleeve Circuit # Screw Washer- Plain Washer- Lock Washer, Gas Line Rotolock- Teflon Circuit # Sight Glass- Gas Line Circuit # Sight Glass- Gas Line Circuit # Fitting, Gas Line- Rotolock Circuit # Fitting, Gas Line- Rotolock Circuit # Nuts- Gas Line Rotolock Fitting Circuit # Heater- Crankcase Circuit # Heater- Crankcase (3/4 & Earlier) Circuit # Heater- Crankcase (4/4 & Later) Circuit # Rail- Trio Compressor Mounting Circuit # Rail- Trio Compressor Mounting Circuit # Spacer Circuit # Screw Circuit # Screw Circuit # Washer Circuit # Washer- Lock Circuit # Washer, Discharge Line Rotolock- Teflon Circuit # Fitting, Discharge Line- Rotolock Circuit # Nuts- Discharge Line Rotolock Fitting Circuit # Seal- Suction Line Rotolock- Teflon Circuit # Tube Fitting, Suction Line- Rotolock (Before /0) Circuit # Tube Fitting, Suction Line- Rotolock (After /0) Circuit # Quantities are for unit. Each circuit has equal quantities of each part. Kit is comprised of four (4) each washer, spacer and sleeve. 3 Quantity is 8 on circuit # and on circuit #. 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 40

141 75 Section M- Condenser Section Compressors & Compressor Components Unit Size 5, 30D: Code 44= R Top View Compressor to Compressor Rail Mounting Detail Circuit # or Circuit # or Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 Side View Discharge Tubing Compressor Rail to Base Channel Mounting Detail ( places) Compressor Rail Circuit # or Circuit # Gas Tubing Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 Suction Tubing 5, 30 Ref. Part Part No. Description Number, Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Compressors- Circuits # OR 3/4 & Earlier Compressors- Circuits # OR 4/4 & Later Mounting Kit Screw Washer- Plain Washer- Lock Washer, Gas Line Rotolock- Teflon Sight Glass- Gas Line Fitting, Gas Line- Rotolock Nuts- Gas Line Rotolock Fitting Heater- Crankcase 3/4 & Earlier Heater- Crankcase 4/4 & Later Rail- Trio Compressor Mounting Screw Washer- Lock Washer, Discharge Line Rotolock- Teflon Fitting, Discharge Line- Rotolock Nuts- Discharge Line Rotolock Fitting Seal- Suction Line Rotolock- Teflon Tube Fitting, Suction Line- Rotolock (Before /0) Tube Fitting, Suction Line- Rotolock (After /0) Quantities are for unit. Each circuit has equal quantities of each part. Kit is comprised of four (4) each washer, spacer and sleeve. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page /30V Compressor Mounting Channel

142 75 Section M- Condenser Section Compressors & Compressor Components Unit Size 40D: Code 44= R Top View or Side View Discharge Tubing 0 Circuit # or Circuit # Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 Compressor Rail to Base Channel Mounting Detail ( places) Circuit # or Circuit # Gas Tubing Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 Suction Tubing Compressor to Compressor Rail Mounting Detail Compressor Rail Compressor Mounting Channel 40 Ref. Part Part No. Description Number, Compressors- Circuit # 3/4 & Earlier Compressors- Circuit # 4/4 & Later Compressors- Circuit # 3/4 & Earlier Compressors- Circuit # 4/4 & Later Compressors- Circuit # 3/4 & Earlier Compressors- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Compressor- Circuit # 3/4 & Earlier Compressor- Circuit # 4/4 & Later Mounting Kit Screw Washer- Plain Washer- Lock Washer, Gas Line Rotolock- Teflon Sight Glass- Gas Line Fitting, Gas Line- Rotolock Nuts- Gas Line Rotolock Fitting Heater- Crankcase (3/4 & Earlier) Circuit # Heater- Crankcase (3/4 & Earlier) Circuit # Heater- Crankcase (4/4 & Later) Circuit #, Rail- Trio Compressor Mounting Screw Washer- Lock Washer, Discharge Line Rotolock- Teflon Fitting, Discharge Line- Rotolock Nuts- Discharge Line Rotolock Fitting Seal- Suction Line Rotolock- Teflon Tube Fitting, Suction Line- Rotolock (Before /0) Tube Fitting, Suction Line- Rotolock (After /0) Quantities are for unit. Each circuit has equal quantities of each part. Kit is comprised of four (4) each washer, spacer and sleeve. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4 08/30V

143 Section M- Condenser Section RCS Pressure Manifolds PC3, PC3, HP, HP, LP, LP, SPTRL Circuit # Circuit # Speedtrol (Code 47=, 4) Speedtrol (Code 47=, 4) Fantrol (Code 47=, ) Fantrol 35 (Code 47=, ) Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switches- Low Pressure Fantrol Unit Code 47=, Speedtrol Unit Code 47=, HP, Switches- High Pressure PC3, 3 Switches- Fan Pressure SPTRL Switch- Speedtrol Pressure Code 47=, Valve Core Valve Cap Fantrol Unit Code 47=, Speedtrol Unit Code 47=, This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 43

144 Section M- Condenser Section RPS/RDT Pressure Controls Box- (03/3 & Earlier) AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 (Note: For RCS units, the Speedtrol Inverters AFD, AFD and Line Reactors [ only] are located in the RCS control box, and the pressure controls for the compressor and fantrol are located on the control box manifolds- see previous page) 44 HP PC SPTRL typ PC3 AFD AFD 35 HP 46 LP SPTRL LP LR LR Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switches- Low Pressure Fantrol Unit Code 47=, Speedtrol Unit Code 47=, HP, Switches- High Pressure PC3, 3 Switches- Fan Pressure SPTRL Switch- Speedtrol Pressure Code 47=, Valve Core Valve Cap Fantrol Unit Code 47=, Speedtrol Unit Code 47=, AFD, Inverter 08/30V Inverter Inverter LR, Line Reactor only (Code 09= 37) On Fantrol units, there is a valve core (ref. # 38) and valve cap in place of each of the SPTRL switches. This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 44

145 Section M- Condenser Section RPS/RDT Pressure Controls Box- (04/3 & Later) AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 (Note: For RCS units, the Speedtrol Inverters AFD/VFD, AFD/VFD and Line Reactors [ only] are located in the RCS control box, and the pressure controls for the compressor and fantrol are located on the control box manifolds.) See Factory Supplied Line Voltage Box Section Ref. Sch. Part Part Qty. No. Sym. Description Number 33, 34 LP, Switches- Low Pressure Fantrol Unit Code 47=, Speedtrol Unit Code 47=, HP, Switches- High Pressure PC3, 3 Switches- Fan Pressure SPTRL Switch- Speedtrol Pressure Code 47=, Valve Core Valve Cap Fantrol Unit Code 47=, Speedtrol Unit Code 47=, , 44 VFD, SpeedTrol VFD Code 54= YY 08/30V, HP , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V 93554, 3HP On Fantrol units, there is a Valve Core and Valve Cap (ref. # 38, 39) in place of each of the SPTRL Switches. Note that ABB brand VFDs are offered as STANDARD. Confirm brand of VFD required BEFORE ordering or contact Daikin Applied. The replacement ABB brand VFD Keypad is p/n For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 45

146 Section M- Condenser Section MicroTech II OR No Controls- RCS Control Box MicroTech II: Code = *D, *S Diagrams Left Side GFS4 PL8 PL9 PL30 GFR4 PB4/4 PVM4 PL5 PL6 PL7 MMP MMP4 MMP6 MMP MMP3 MMP5 DS4 or PB4 M M4 M6 M M3 M5 TB8 CCB Controller Detail Standoff Expansion Board Standoff Right Side Comm. Card TD TD TB R R 7 R R FUA FUB FUC T REC CS CS S CCB CCB T9 PS PS RES LR LR MMP MMP4 MMP MMP4 AFD AFD M M3 M4 M5 M M3 M4 M5 TC4 TC Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 46

147 Left Side Section M- Condenser Section MicroTech II OR No Controls- RCS Control Box No Controls: Code = YC, YM Diagrams GFS4 PB4/4 PVM4 GFR4 PL8 PL9 PL30 PL5 PL6 PL7 MMP MMP4 MMP6 MMP MMP3 MMP5 DS4 or PB4 M M4 M6 M M3 M5 TB8 Right Side TD TD FUA FUB FUC T CS CS S REC R R R R R R 7 R R R R T9 PS PS TB TB3 TB5 TB6 MMP MMP3 MMP MMP3 TC4 TC M M M3 M4 M M M3 M4 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 47

148 Section M- Condenser Section MicroTech II OR No Controls- RCS Control Box Components Sch. Part Part Qty. Sym. Description Number Controllers Code = *D, *S CCB, Expansion Boards- Compressor Controller 060 Standoff- Expansion Board Com. Card- Bacnet Standoff- Com. Card RES Resistor- CCB Switches PS, Switches- Pumpdown CS, Switches- Control- Pole S Switch- System REC Receptacle Relays R, Relays- Hi Pressure Reset R5. Relay- Safety R6. Relay- Safety R7. Relay- Safety R8. Relay- Safety R Relay- Inverter AFD Code 47=, R3. Relay- Safety R4. Relay- Safety R7 Relay- Inverter AFD Code 47=, TD, Time Delays- Compressor Lockout 4 TC, 4 Temperature Controls- FanTrol Ground Fault Protection GFR4 Ground Fault Relay- SPDT Code 7= YG, YC GFS4 Ground Fault Sensor Code 7= YG, YC Phase Voltage Monitor Code 7= YP, YC PVM4 08/30/ Units (/6 & Earlier) 000 Units (/6 & Earlier) /30/ Units (/7 & Later) Units (/7 & Later) Socket, PVM (/7 & Later) Plugs PL5-30 Plugs- Pin /comp Terminal Blocks TB,3,5,6,8 Terminal Blocks var. Transformers T Transformer- Main 3 T9 Transformer- 5/4VAC SpeedTrol Inverters Code 47=, 4 AFD, Inverters 08/30V Inverters Inverters SpeedTrol Line Reactor Code 47=, 4 LR, Line Reactors only (Code 09= 37) Part number is for one section. Quantity of sections varies with unit options. Ground Terminal is p/n Original non-adjustable Relay has been replaced with an adjustable version. 3 See following page. 4 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n The ADJUSTABLE version of this relay could also have been supplied: p/n Confirm which relay is required BEFORE ordering. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 48

149 Section M- Condenser Section MicroTech II OR No Controls- RCS Control Box Components, Continued Sch. Part Part Qty. Sym. Description Number Disconnect Code = A, A DS4 Switch- Disconnect 00A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 50A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 50A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 400A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 600A Handle- Disconnect Shaft Mod Lug- Ground Power Block PB4, 4 Power Block, Main 75A A, 40A A A Cover- Power Block 760A only Contactors M- 6 Contactors- Compressors M- 5 Contactors- Fan Motors Manual Motor Protector MMP- 6 MMP- Compressors MMP- 5 MMP- Fan Motors SpeedTrol Fuses F, Fuses- SpeedTrol Motor Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. These components are detailed in the Main Control Box (Section N). 3 Note that the original M frame disconnect is obsolete and replaced with a P frame switch. Due to dimensional differences minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 49

150 Section M- Condenser Section MicroTech III- RCS Control Box: Code = *E, *F, *W Diagrams RCS with MicroTech III Controls: Code = *E, *F, *W 03/3 & Earlier RCS with MicroTech III Controls: Code = *E, *F, *W 04/3 & Later The above diagrams show typical Condenser Control Box layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 50

151 Section M- Condenser Section MicroTech III- RCS Control Box: Code = *E, *F, *W Components Sch. Part Part Qty. Sym. Description Number Switches CS, Switches- Control Code = A Code = A S Switch- System Receptacle REC Receptacle Relays R Relay- Inverter AFD Code 47=, R Relay- Condenser Fans R4 Relay- Condenser Fans R7 Relay- Inverter AFD Code 47=, Ground Fault Protection GFR4 Ground Fault Relay- SPDT Code 7= YG, YC GFS4 Ground Fault Sensor Code 7= YG, YC Phase Voltage Monitor Code 7= YP, YC Phase Voltage Monitor PVM4 08/30/ Units (/6 & Earlier) 000 Units (/6 & Earlier) /30/ Units (/7 & Later) Units (/7 & Later) Socket, PVM (/7 & Later) Plugs PL5-30 Plugs- Pin /comp Terminal Blocks TB,3,5,6,8 Terminal Blocks var. Power Block PB4 Power Block, Main 75A A, 40A A A Cover- Power Block 760A only Temp. Controls TC, 4 Temperature Controls- Fantrol Transformers T9 Transformer- Secondary Contactors M- 6 Contactor- Compressors 3 M- 5 Contactor- Fan Motors 3 Manual Motor Protector MMP- 6 MMP- Compressors 3 MMP- 5 MMP- Fan Motors 3 Part number is for one section. Quantity of sections varies with unit options. Ground Terminal is p/n Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. 3 These components are detailed in the Main Control Box (Section N). Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

152 Section M- Condenser Section MicroTech III- RCS Control Box: Code = *E, *F, *W Components, Continued Disconnect Switches 03/3 & Earlier Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS4 Disconnect Switch- Condenser Control Box Switch- 00A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. For DSs larger than 400A, contact Daikin Applied with model and serial number information so that the correct parts(s) can be identified. Disconnect Switches 04/3 & Later Ref. Part Part Voltage NO. Description Number 08V 30V Disconnect Switch DS4 Disconnect Switch- Condenser Control Box Switch- 00A Handle 9340 Shaft Switch- 50A Handle 9340 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. For DSs larger than 400A, contact Daikin Applied with model and serial number information so that the correct parts(s) can be identified. 3 This Shaft is 4.5 OAL and is designed to be cut to length in the field. 4 This Shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

153 Section M- Condenser Section Factory Supplied Line Voltage Box- Powered Receptacle and Lights Code 8= U***, V*** OR Code 3= ***F* T6, DS6, FU6A, FU6B, FU6C 03/3 & Earlier T6 DS6 8 L L L3 9 3 FU6C FU6B FU6A T T T3 Voltage Ref. Sch. Part Part No. Sym. Description Number T6 Transformer KVA Transformer KVA Transformer KVA V 30V 3 DS6 Disconnect Switch 30A/600V FU6A, B Fuse 0A/600V Fuse 0A/600V Fuse 8A/600V FU6C Fuse 0A/600V /3 & Later Voltage Ref. Sch. Part Part No. Sym. Description Number 47 T6 Transformer KVA Transformer KVA Transformer KVA N/S Finger Safe Cover Kit DS6 Fuse Holder/Circuit Protector 3 P, 30A, 600V FU6A, B Fuse 3 0A/600V Fuse 3 0A/600V Fuse 3 8A/600V FU6C Fuse 3 0A/600V Fuseblock 3 P, 30A, 500V Fuse Cover/Puller N/S= Not Shown on Diagram. Located in the Pressure Controls Box. pc. PER Fuse. 3 Located in the Main Control Box, Power Panel section. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 53

154 Section N- Main Control Box Notes Primary Codes that pertain: 08, 09, 0,,, 3, 4, 5, 7, 8, 3 & 68 Additional Codes that pertain: 04, 9, 0,, 7, 3, 34, 35, 40, 47 The Main Control Box applies to the RPS, RFS and RDT. The RCS has its own Controls that are detailed in Section M. The Main Control Box is comprised of three primary parts The Deadfront Door with the keypad, the Control Panel, and the Power Panel. In March and April of 03, the Main Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and VFD circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable. For units built and shipped during the transition, confirm which design was used, or contact Daikin Applied to ensure that the correct part(s) are identified. Code 08 determines where the Control Box is installed- D indicates the discharge plenum (RPS, RFS), F indicates the supply air section (RDT). Code 9 is the unit voltage and affects Transformers, Fan Overloads/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Power/Terminal Block or a through-the-door Disconnect. Code determines which Control system was used (MicroTech II, III, OR No Controls), the type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, or None), and whether the unit uses Discharge Temperature, Space Control, or Zone control. There is an MCB and separate Expansion Boards/Modules (Condenser, Electric Heat) in the Control Panel. Units may also have no unit controls (Code = YM, YC) in which case the Main Control Box has no MCB or Expansion Boards, but instead has a set of Relays. RCS Standalone Units (units that are designed to be used as a standalone condensing unit, or intended to be hooked to an RFS unit) have additional codes which add Transformers. For RCS Standalone Unit specific information, (Code = *A), refer to RPL form # Code 3 determines the presence of Duct and/or Space Sensors. Codes 4 and 5 determine the Supply and Return Fan Inverter characteristics. Codes 7 AND/OR 3 (Mid 0 & Later) determine miscellaneous electrical options including whether the unit has a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc. Code 68 specifies the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at 0 SCCR (Code 68= 0, OR no entry). An entry with any other rating (Eg: Code 68=, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 8 indicates whether a unit has a Remote Keypad Display, a unit mounted Receptacle, or a Modem. Codes 9, 0 and are Return Air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air motor, etc, have an impact on Contactors, Overloads/MMPs, Fuses, and Duct Sensors. Code 7 determines the draw through section, and can impact the Cooling Circuit Relays. Code 3 determines horsepower for the Supply Fan Motor which, like the Return Air Motor will affect Contactors, Motor Protectors, Fuses, Overloads, etc. Codes 04, 30, (RDT) 34, and 35 determine the BlowThru section, and the heat type, which will impact the Transformers, Heat Circuit Relays, and Cooling Circuit Relays. Code 40 determines if there is a VAV/Discharge Damper and associated Relay. Code 47 determines if the unit has SpeedTrol fan control and affects the Condenser Fan fusing, and whether there are SpeedTrol Inverters and associated components. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 54

155 Section N- Main Control Box Control Box Component Label Diagram Note that starting in late 00 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 55

156 Section N- Main Control Box MicroTech II OR No Controls- Control Panel Units with Controller (Code = *D, *S)- Diagrams R R R 0 R R 45 R 6 R R R R R RES CCB CCB R R 6 66 R 67 R 68 R 69 Left Side Door T9 T T3 EHB SPS SPS TB T4 MCB Inverter Display SERIAL DHL Left Side Door- Detail Remote Keypad See Power Panel Keypad Display Switches Detail HS S CS CS S4 S7 PS PS The above diagrams show a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 56

157 Section N- Main Control Box MicroTech II OR No Controls- Control Panel Units with No Controller (Code = YM, YC)- Diagram R R R 0 R R 45 R R R R R R 63 R 5. R 6. R 7. R 8. R 9 R 0 R 6 R 67 R 69 R R 3. R 4. T R 66 R 68 R 70 R 7 TD TD TB T4 DHL Switches Detail HS S CS CS S4 S7 PS PS See Power Panel The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 57

158 Section N- Main Control Box MicroTech II OR No Controls- Control Panel Components Sch. Part Part Qty. Sym. Description Number Main Controller Code = *D, *S MCB Main Controller- Must be programmed (unit GO# required) Com Card- Bacnet Code = B* Com Card- Bacnet with Ethernet Code = E* Com Card- LonMark Space Control Code = LS Com Card- LonMark Discharge Control Code = LD Standoff- Com Card Kit- Connector Repair Power Supply- 5 VDC Serial Port Ribbon Cable 0470 Battery Grounding Bar Keypad Code = *D, *S Keypad Keypad Remote Keypad Interface Board 060 Cable- Interface Compressor Controller Code = *D, *S CCB, Expansion Boards- Compressor Controller 060 Standoff- Expansion Board Com.. Card- Bacnet Standoff- Com. Card RES Resistor- CCB Electric Heat Board EHB Expansion Board- Electric Heat 060 Standoff- Expansion Board Com. Card- Bacnet Standoff- Com. Card Switches- Control HS Switch- Electric Heat Shutdown Code 04= E PS, Switches- Pumpdown CS, Switches- Control with Controller Code = *S, *D S with no Controller Code = YM, YC Switch- System On/Off Gas Heat Units Code 04= A Elec.,Steam,HW or No Heat Code 04= E, S, W, Y S4 Switch- Inverter Bypass On/Off S7 Switch- Local On/Auto/Off to Controller Serial Cables Serial Serial Cable 0470 Duct Hi Limit and Duct Static Pressure Sensors DHL Duct Hi Limit Switch SPS Pressure Transducer- Duct Sensor Code 3=,, SPS Pressure Transducer- Duct Sensor Code 3= Pressure Transducer- Space Sensor Code 3= 3, Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 58

159 Section N- Main Control Box MicroTech II OR No Controls- Control Panel Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R, Relays- Hi Pressure Reset R5.,6. Relays- Safety R7.,8. Relays- Safety R9, 0 Relay- Compressor Lockout R, 7 Relays- SpeedTrol Code 47=, R3.,4. Relays- Safety R8, 9 Relay- Cool Failure Indicator R0 Relay- Steam or Hot Water Heat Code 04= S, W Units with Controller Code = *D, *S Units with No Controller Code = YM Relay- Electric Heat Code 04= E R4 Relay- Gas Heat Alarm Code 04= A R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R6 Relay- Iso Damper- Open/Close R8 Relay- Isolation Damper Safety R30 Relay- Cool Valve w/ Face Bypass R45 Relay- UV Lights R46/47 Relay- Inverter, Supply Fan increase/decrease Code 4= -3, R48/49 Relay- Inverter, Return Fan increase/decrease Code 4=,4,5, R6 Relay- Discharge Air Smoke Detector R63 Relay- Specials R66, 70 Relays- Return Air Smoke Detector Code 6=, R67 Relay- Supply Fan Enable No Controller with inverter bypass Code = YM, YC No Controller with no inverter bypass Code = YM, YC R68 With Controller Code = *D, *S Relay- Return Fan Enable No Controller Code = YM, YC With Controller Code = *D, *S R69 Relay- Inverter Bypass VAV Interlock Code 4= Time Delays TD, Time Delays- Compressor Lockout 3 Transformers- Controls T Transformer- Control Input 5-4V With Controller Code = *D, *S No Controller Code = YM, YC T3 Transformer- Control Output 5-4V T4 Transformer- Exhaust Damper Actuator 5- VDC T9 Transformer- Refrigerant Circuit 4V Terminal Blocks TB Terminal Block- Internal Sensors ZNT Sensor- Zone Temperature w/ Tenant Override 0480 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., 0480 DAT Sensor- Discharge Air Temperature ENT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature SCC Units only- Code = BS, LS, ES, SS. Not Shown on diagram. 3 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n The ADJUSTABLE version of this relay could also have been supplied: p/n Confirm which relay is required BEFORE ordering. 4 Varies depending on unit options. Part number is for one individual section. Ground block is p/n Jumpers are p/n (TBA:5), (TBB:4), (TBC:0,TBD:5 & TBE:30). Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 59

160 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (03/3 & Earlier) Code = *E, *F, *W- Diagram See Power Panel See Power Panel The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 60

161 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (03/3 & Earlier) Code = *E, *F, *W- Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect, Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole MicroTech III Remote Unit Keypad/Interface Display Terminal Block, MCB- 8 Pole Expansion Module EXP A Expansion Module- Condenser EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Communication Card COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge (Code = LE, LW) LonWorks- Constant Volume (Code = LF) Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistors- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/0A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer Kit- Duct Sensor (9/ & Earlier) 3, Pressure Transducer- Duct Sensor (0/ thru 3/3) Pressure Transducer Kit- Space Sensor (9/ & Earlier) 3, Pressure Transducer- Space Sensor (0/ thru 3/3) Not Shown on diagram. Quantity varies depending upon unit options selected. 3 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. 4 As of 09/ the original Pressure Transducer is no longer available. The Transducer Kit includes Transducer, Dinrail, Resistor, Sampling Tube, and Installation Instructions. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

162 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (03/3 & Earlier) Code = *E, *F, *W- Components, Continued Sch. Part Part Qty. Sym. Description Number Hot Gas Reheat 3 Code 48= H, K RHB, Interface Boards, Hot Gas Reheat Relays R Relay- Condenser Fan R4 Relay- Condenser Fan R0 Relay- Heat R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R6 Relay- Iso Damper- Open/Close R8 Relay- Isolation Damper Safety R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y R8 Relay- Smoke 4P/6A/4V R8 Relay- Smoke 4P/6A/4V R83 Relay- Smoke 4P/6A/4V R84 Relay- Smoke 4P/6A/4V R85 Relay- Smoke 4P/6A/4V R86 Relay- Smoke 4P/6A/4V R87 Relay- Smoke 4P/6A/4V R88 Relay- Smoke 4P/6A/4V Time Delays TD0 Time Delay- Return Air Fan Terminal Block TB Terminal Block Sensors ZNT Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only- Code = BF, LF, EF, SF. 3 Not Shown on diagram. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

163 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (04/3 & Later) Code = *E, *F, *W- Diagram See Power Panel See Power Panel The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 63

164 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (04/3 & Later) Code = *E, *F, *W- Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad/Interface Display Expansion Module EXP A Expansion Module- Condenser/ Energy Recovery EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Communication Card COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge Code = LE, LW LonWorks- Constant Volume Code = LF Hot Gas Reheat Code 48= H, K OR Code 54= BM RHB, Interface Boards, Hot Gas Reheat Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/0A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer- Duct Sensor Pressure Transducer- Space Sensor Snubber, Pressure Transducer (optional; field installed) 90870, Not Shown on diagram. Quantity varies depending upon unit options selected. 3 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 64

165 C F Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (04/3 & Later) Code = *E, *F, *W- Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- SpeedTrol inverter VFD R Relay- Condenser Fan R3 Relay- Condenser Fan R4 Relay- Condenser Fan R7 Relay- SpeedTrol inverter VFD R0 Relay- Heat R Relay- Gas Heat R4 Relay- Gas Heat Alarm R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R6 Relay- Iso Damper- Open/Close R8 Relay- Isolation Damper Safety R45 Relay- UV Lights R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y R8 Relay- Inverter Reset 4P/6A/4V R8 Relay- Inverter Reset 4P/6A/4V R83 Relay- Smoke 4P/6A/4V R84 Relay- Smoke 4P/6A/4V R85 Relay- Smoke 4P/6A/4V R86 Relay- Smoke 4P/6A/4V R87 Relay- Smoke 4P/6A/4V R88 Relay- Smoke 4P/6A/4V Time Delays TD0 Time Delay- Return Air Fan Terminal Block TB Terminal Block Sensors ZNT Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., SHS Sensor, Humidity Duct Mounted 3 /6 & Earlier Sensor, Humidity Duct Mounted 3 /7 & Later Sensor, Humidity Wall Mounted DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only (Code = *F). 3 Not Shown on diagram. 4 In late 03, Digital Room Sensor p/n was added as the preferred option. The other Zone Temperature Sensors are available as options. For positive p/n identification, refer to the drawings below. ZNT Sensor ZNT Sensor 3770 ZNT Sensor 3780 Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 65

166 Section N- Main Control Box Power Panel: (03/3 & Earlier) Diagrams See Control Panel See Control Panel Plugs PL- 43 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 66

167 Section N- Main Control Box Power Panel: (03/3 & Earlier)- Components Power Panel- Terminal Blocks, T Transformer & Fusing Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB, 7 Terminal Block TB3, 4 Terminal Block Transformer- Main 3 T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Fuses- T F.A, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= F.C Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Varies depending on unit options. Part number is for one individual section. Ground block is p/n Varies depending on unit options. Part number is for one individual section. When required, Jumpers are p/n ( pole), (3 pole), (4 pole), (5 pole). 3 All T transformers also use a Cover Kit p/n & Fuse Puller Kit p/n (not used on Transformer p/ns , , Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; = Non- Gas Heat Units with no UV lights. 5 Fuses used on Gas Heat Unit w/uv lights also use fuse block p/n & 3 pullers p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 67

168 Section N- Main Control Box Power Panel: (03/3 & Earlier)- Components, Continued Power Panel- Fusing continued, Phase Protection, Ground Fault, Power Blocks Sch. Part Part Voltage Sym. Description Number 08V 30V Fuses, continued F,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor mbh furnace Fuse- Blower Motor 000 mbh furnace F5 Fuse- UV Lights Code 7 [nd digit]= Phase Voltage Code 7 [nd digit]= P, A, C, D, H, J, K PVM, Phase Voltage Monitor 000 Phase Voltage Monitor 000 Ground Fault Code 7 [nd digit]= G, B, C, D, K GFR, Ground Fault Relay- SPDT GFS, Ground Fault Sensor Power Blocks PB, PB Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 40A Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat , 00, 40, 80, 30 KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. PB is installed when Code = Q. These Power Blocks are used on RPS and RDT units. RFS units use the following: 75A p/n Lug p/n ; 30A p/n Lug p/n ; 40A p/n Lug ; 760A p/n Lug p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 68

169 Section N- Main Control Box Power Panel: (03/3 & Earlier)- Components, Continued Power Panel- Power Blocks, Receptacle, Power Supply Board, Disconnect Switch Sch. Part Part Voltage Sym. Description Number 08V 30V Power Blocks, continued PB0 Power Block- Supply Fan Code 5= F PB0 Power Block- Return Fan Code 5= F Receptacles REC Receptacle Power Supply Board Code = *D, *S PWR Power Supply Board 5V Disconnect Switch DS Disconnect Switch- Main Gas, Steam, HW, No Heat Code 04= A, S, W, Y Switch- 00A Handle Kit Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 600A,, 3, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. The 600A switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (Code = A, B). 3 If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n , Handle Kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 69

170 Section N- Main Control Box Power Panel: (03/3 & Earlier)- Components, Continued Power Panel- Disconnect Switch Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch, continued DS Disconnect Switch- Main Electric Heat Code 04= E Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Switch- 600A,, 3, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. The 600A switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (Code = A, B). 3 If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n , Handle Kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 70

171 Section N- Main Control Box Power Panel: (03/3 & Earlier)- Components, Continued Power Panel- Disconnect Switch (continued), Circuit Breakers Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch, continued DS Disconnect Switch- SAF/RAF Code = C, D Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Circuit Breakers CB0 Circuit Breaker CB0 Circuit Breaker- Return Fan Motor HP= 5, 7.5, Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= 0, Motor HP= Motor HP= Motor HP= 5, Any of the listed Disconnect Switches may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

172 Section N- Main Control Box Power Panel: (03/3 & Earlier)- Components, Continued Power Panel- Circuit Breakers (continued), Plugs Sch. Part Part Voltage Sym. Description Number 08V 30V Circuit Breakers, Continued CB0 CB0 Circuit Breaker Circuit Breaker- Return Fan Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Plugs 4 Pin Plug varies varies varies varies 3 6 Pin Plug varies varies varies varies 4 Pin Plug varies varies varies varies 5 3 Pin Cap Kit varies varies varies varies 6 6 Pin Cap Kit varies varies varies varies 7 9 Pin Cap Kit varies varies varies varies 8 5 Pin Cap Kit varies varies varies varies All possible Plugs used are listed. Check actual unit to verify which Plug is required. Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 3 Used with Strain Relief (p/n ) & 6 Pin Cap Kit (p/n ). Used for PL0, PL. 4 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 5 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

173 Section N- Main Control Box Power Panel: (03/3 & Earlier) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Diagrams Aux. Contact Front Mtd. Contact 3D Link 3E 3B 3 MMP Contactor Short Circuit Alarm 3D MMP 3 3E Contactor Front Mounted Contact MMP 3 Lug Trip Indicator Alarm Contactor 3F 3G MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5, 7.5 HP Motors- All Voltages 0 HP Motor- 30/460/ 5, 0 HP Motor- 460/ 5, 30 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 0HP Motor- 08V 5HP Motor- 08/30V 0 HP Motors- 08/30V 5 HP Motors- 30/ 30 HP Motors- 40 HP Motors- 460/ 50 HP Motors- 460/ 60 HP Motors- NOTE: The diagrams show all possible parts. Not every part shown applies to every unit size/voltage combination. MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 08V 30 HP Motors- 30V 60 HP Motors- Lug 3G 3G Lug MMP 3 3 MMP Trip Ind. Interlock 3F 3F Trip Ind. Interlock Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 30 HP Motors- 08V 40 HP Motors- 08/30V 50 HP Motors- 30V 75 HP Motors- 460/ MMP0 & M0 Link Detail 50 HP Motors- 08V 60 HP Motors- 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 73

174 5 HP Motor- Code OR 3= J*Y Section N- Main Control Box Power Panel: (03/3 & Earlier) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Components Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC V 30V 7.5 HP Motor- Code OR 3= K*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 74

175 0 HP Motor- Code OR 3= L*Y Section N- Main Control Box Power Panel: (03/3 & Earlier) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Components Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC V 30V 5 HP Motor- Code OR 3= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC V 30V 0 HP Motor- Code OR 3= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 75

176 5 HP Motor- Code OR 3= P*Y Section N- Main Control Box Power Panel: (03/3 & Earlier) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Components Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) V 30V 30 HP Motor- Code OR 3= Q*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 76

177 40 HP Motor- Code OR 3= R*Y Section N- Main Control Box Power Panel: (03/3 & Earlier) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Components Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan E Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 ring terminals. 08V 30V 50 HP Motor- Code OR 3= S*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan E Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 ring terminals. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 77

178 60 HP Motor- Code OR 3= T*Y Section N- Main Control Box Power Panel: (03/3 & Earlier) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Components Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan E Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) Lug (3 per kit) Also requires 3 ring terminals. 08V 30V 75 HP Motor- Code 3= U*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan MMP0 MMP- Supply Fan F Trip Indicator Interlock G Lug Note that 75HP motors are not available for Supply Air Fans in 08/30V. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 78

179 Section N- Main Control Box Power Panel: (03/3 & Earlier) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 080, 08D MMP 3 Front Mounted Contact 3E Front Mounted Contact A Contactor Front Mounted Contact 3E Front Mounted Contact Link A 3B 3 MMP Contactor MMP-6 & M-6 Contactor Link Detail 08/30V MMP-6 & M-6 Contactor Link Detail 460/ 080, 08 Ref. Sch. Part Part No. Sym Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor M- 6 Contactor- Compressor A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 6 Manual Motor Protector- Compressor Manual Motor Protector- Compressor Manual Motor Protector- Compressor B Link E Front Mounted Contact- NO or NC /30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 79

180 Section N- Main Control Box Power Panel: (03/3 & Earlier) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 085 thru 09D MMP 3 Front Mounted Contact 3E Front Mounted Contact 3E 3 MMP Front Mounted Contact A Contactor MMP & Contactor Link Detail 08/30V Link Front Mounted Contact A 3B MMP & Contactor Link Detail 460/ Contactor Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor M- 6 Contactor- Compressor A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP-6 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr B Link E Front Mounted Contact- NO /30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 80

181 Section N- Main Control Box Power Panel: (03/3 & Earlier) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 00, 0D MMP 3 Front Mounted Contact 3E Contactor Front Mounted Contact A MMP, 3, 5 & M, 3, 5 Contactor Link Detail- 460/ Lugs MMP 4 4F Front Mounted Contact 3E Front Mounted Contact Link A 3B MMP MMP, 3, 5 & M, 3, 5 Contactor Link Detail- 08/30V MMP Front Mounted Contact 4E 4 3 Contactor Contactor Front Mounted A Contact MMP, 4, 6 & M, 4, 6 Contactor Link Detail- 08V Front Mounted Contact A MMP, 4, 6 & M, 4, 6 Contactor Link Detail- 30/460/ 00, 0 Contactor Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor, Circuit # M, 3, 5 Contactor- Compressor, Circuit # A Front Mounted Contact- NO- NC M, 4, 6 Contactor- Compressor, Circuit # Contactor- Compressor, Circuit # Contactor- Compressor, Circuit # A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP, 3, 5 Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # B Link E Front Mounted Contact- NO MMP, 4, 6 Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # E Front Mounted Contact- NO F Lug Kit (3 lugs per kit) V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

182 Section N- Main Control Box Power Panel: (03/3 & Earlier) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 05, 0D Lugs MMP 3 3F MMP Front Mounted Contact 3E 3 Contactor Front Mounted A Contact MMP - 6 & M- 6 Contactor Link Detail- 08V Contactor Front Mounted Contact A MMP - 6 & M- 6 Contactor Link Detail- 30/460/ 05, 0 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor Contactor- Compressor Contactor- Compressor A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 6 Manual Motor Protector- Compressor Manual Motor Protector- Compressor Manual Motor Protector- Compressor E Front Mounted Contact- NO F Lug Kit (3 lugs per kit) V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

183 Section N- Main Control Box Power Panel: (03/3 & Earlier) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 0D Lugs 3F or MMP 3 or 4 4F MMP Front Mounted Contact 3E or 3 or 4E 4 Front Mounted Contact A or A or Contactor Front Mounted Contact A or A or Contactor MMP - 6 & M- 6 Contactor Link Detail- 08V MMP, 4, 6 & M, 4, 6 Contactor Link Detail- 30V MMP - 6 & M- 6 Contactor Link Detail- 460/ MMP, 3, 5 & M, 3, 5 Contactor Link Detail- 30V Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor, Circuit # Contactor- Compressor, Circuit # Contactor- Compressor, Circuit # A Front Mounted Contact- NO- NC M, 4, 6 Contactor- Compressor, Circuit # Contactor- Compressor, Circuit # A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP, 3, 5 Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # E Front Mounted Contact- NO F Lug Kit (3 lugs per kit) MMP, 4, 6 Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # E Front Mounted Contact- NO F Lug Kit (3 lugs per kit) V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 83

184 Section N- Main Control Box Power Panel: (03/3 & Earlier) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 5, 30D Lugs 3F MMP 3 MMP 3 Front Mounted Contact 3E Front Mounted Contact A Contactor Front Mounted Contact A Contactor MMP - 6 & M- 6 Contactor Link Detail- 08V MMP,4, 6 & M, 4, 6 Contactor Link Detail- 30V MMP - 6 & M- 6 Contactor Link Detail- 460/ MMP, 3, 5 & M, 3, 5 Contactor Link Detail- 30V 5, 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor Contactor- Compressor A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP- 6 Manual Motor Protector- Compressor Manual Motor Protector- Compressor Manual Motor Protector- Compressor E Front Mounted Contact- NO F Lug Kit (3 lugs per kit) V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 84

185 Section N- Main Control Box Power Panel: (03/3 & Earlier) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 40D Lugs 3F or MMP 3 or 4 4F MMP Front Mounted Contact 3E or 3 or 4E 4 Front Mounted Contact A or A or Contactor Front Mounted Contact A or A or Contactor MMP - 6 & M- 6 Contactor Link Detail- 08V MMP, 4, 6 & M, 4, 6 Contactor Link Detail- 30V MMP - 6 & M- 6 Contactor Link Detail- 460/ MMP, 3, 5 & M, 3, 5 Contactor Link Detail- 30V Ref. Sch. Part Part No. Sym Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor, Circuit # Contactor- Compressor, Circuit # A Front Mounted Contact- NO- NC M, 4,w 6 Contactor- Compressor, Circuit # Contactor- Compressor, Circuit # A Front Mounted Contact- NO- NC Compressor MMP s & Parts 3 MMP, 3, 5 Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # E Front Mounted Contact- NO F Lug Kit (3 lugs per kit) MMP, 3, 5 Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # Manual Motor Protector- Compressor, Circuit # E Front Mounted Contact- NO F Lug Kit (3 lugs per kit) V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 85

186 Section N- Main Control Box Power Panel: (03/03 & Earlier) Condenser Fan Contactors, MMPs, & Fusing FanTrol Units: Code 47= MMP 8 8 MMP Link 8B 8B Link 7 One Contactor Arrangement 7A Spacer Contactor 8C Bus Bar Contactor 7 7A Spacer Two Contactor Arrangement 080, , 09 00, , , 0 0 Ref. Part Part No. Symbol Description Number Contactors & Parts 7 M Contactor 9A Contactor A M Contactor 9A M3 Contactor 9A M4 Contactor 9A Contactor A M Contactor 9A Contactor A M Contactor 9A M3 Contactor 9A M4 Contactor 9A Contactor A A Spacer /30V 08/30V 08/30V 08/30V 08/30V MMP s & Parts 8 MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Note that the addition of Hot Gas Reheat (Code 48= H, K OR Code 54= B*) can alter the number of contactors and motor protectors. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 86

187 Section N- Main Control Box Power Panel: (03/03 & Earlier) Condenser Fan Contactors, MMPs, & Fusing FanTrol Units: Code 47=, Continued 080, , , , 0 0, 0 Ref. Part Part No. Symbol Description Number 8 MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP C Bus Bar Note that the addition of Hot Gas Reheat (Code 48= H, K OR Code 54= B*) can alter the number of contactors and motor protectors. 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 87

188 Section N- Main Control Box Power Panel: (03/3 & Earlier) Condenser Fan Contactors, MMPs, & Fusing Quiet Fan FanTrol Units Code 47= 3, 3 8 MMP 8B Link 7A Spacer 7 Contactor , Ref. Part Part No. Symbol Description Number Contactors & Parts 7 M Contactor 9A M Contactor 9A M3 Contactor 9A M4 Contactor 9A M Contactor 9A M Contactor 9A M3 Contactor 9A M4 Contactor 9A M5 Contactor 9A M6 Contactor 9A A Spacer MMP s & Parts 8 MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Contact Daikin Applied with model and serial number information so that the required part(s) can be identified. For units with SpeedTrol and Quiet Fans (Code 47= 4) contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Note that the addition of Hot Gas Reheat (Code 48= H, K OR Code 54= B*) can alter the number of contactors and motor protectors. 3 For unit sizes and voltages not listed contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 88

189 Section N- Main Control Box Power Panel: (03/3 & Earlier) Condenser Fan Contactors, MMPs, & Fusing Quiet Fan FanTrol Units Code 47= 3, Continued, 3 Ref. Part Part No. Symbol Description Number 8 MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP5 Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP6 Manual Motor Protector Manual Motor Protector 8B Link- MMP Contact Daikin Applied with model and serial number information so that the required part(s) can be identified. For units with SpeedTrol and Quiet Fans (Code 47= 4) contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Note that the addition of Hot Gas Reheat (Code 48= H, K OR Code 54= B*) can alter the number of contactors and motor protectors. 3 For unit sizes and voltages not listed contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 08/30V , /30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 89

190 Section N- Main Control Box Power Panel: (03/03 & Earlier) Condenser Fan Contactors, MMPs, & Fusing SpeedTrol Units: Code 47= 3 MMP & Contactors Detail Speedtrol Fuses MMP 8 Adapter 4 8B Link 7 8 MMP Link 8B 8C Bus Bar 7A Spacer Contactor Contactor 7 7A Spacer Puller Fuse 3 Fuse Block One Contactor Arrangement Two Contactor Arrangement F, F 080, , 40 05, 0 0 Ref Schematic Part Part No. Symbol Description Number Speedtrol Fusing FB, Fuse Block Fuse Cover/Puller F Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol F Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol DIN Rail Adapter Cond. Fan Contactors 7 M- 6 Contactor- Cond. Fan A - Spacer Fan MMP s & Parts 8 MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Quantity varies depending upon unit size. Confirm the number of parts required BEFORE ordering. 3 Note that the addition of Hot Gas Reheat (Code 48= H, K OR Code 54= B*) can alter the number of contactors and motor protectors. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 90 08/30V 08/30V 08/30V 08/30V 08/30V

191 Section N- Main Control Box Power Panel: (03/03 & Earlier) Condenser Fan Contactors, MMPs, & Fusing SpeedTrol Units: Code 47=, Continued 4 080, , , 40 05, 0 Ref Schematic Part Part No. Symbol Description Number MMP4 Manual Motor Protector Manual Motor Protector MMP5 3 Manual Motor Protector Manual Motor Protector MMP6 3 Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP4 Manual Motor Protector Manual Motor Protector MMP5 3 Manual Motor Protector Manual Motor Protector MMP6 3 Manual Motor Protector Manual Motor Protector 8B - Link- MMP C - Bus Bar Contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Quantity varies depending upon unit size. Confirm the number of parts required BEFORE ordering. 3 Note that MMP5, 6, 5, 6 are used on unit size 40D only. 4 Note that the addition of Hot Gas Reheat (Code 48= H, K OR Code 54= B*) can alter the number of contactors and motor protectors. 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

192 Section N- Main Control Box Power Panel: (04/3 & Later) Diagrams See Control Panel See Control Panel Plugs PL- 43 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

193 Section N- Main Control Box Power Panel: (04/3 & Later)- Components Power Panel- Terminal Blocks, T Transformer & Fusing Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB, 7 Terminal Block TB3, 4 Terminal Block Transformer- Main 3 T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Fuses- T F.A, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= F.C Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Varies depending on unit options. Part number is for one individual section. Ground block is p/n Varies depending on unit options. Part number is for one individual section. When required, Jumpers are p/n ( pole), (3 pole), (4 pole), (5 pole). 3 T transformers use Cover Kit p/n & Fuse Puller kit p/n (not used on transformer p/n , , Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; = Non- Gas Heat Units with no UV lights. 5 Fuses used on Gas Heat Unit w/uv lights also use Fuseblock p/n & 3 Pullers p/n Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 93

194 Section N- Main Control Box Power Panel: (04/3 & Later)- Components, Continued Power Panel- Fusing continued, Phase Protection, Ground Fault, Power Blocks Sch. Part Part Voltage Sym. Description Number 08V 30V Fuses, continued F,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor MBH furnace Fuse- Blower Motor 000 MBH furnace F5 Fuse- UV Lights Code 7 [nd digit]= Phase Voltage 3 Code 7 [nd digit]= P, A, C, D, H, J, K PVM, Phase Voltage Monitor (/6 & Earlier) Phase Voltage Monitor (/6 & Earlier) Phase Voltage Monitor (/7 & Later) Phase Voltage Monitor (/7 & Later) Socket, PVM (/7 & Later) Ground Fault 3 Code 7 [nd digit]= G, B, C, D, K GFR, Ground Fault Relay- SPDT GFS, Ground Fault Sensor Power Blocks PB, PB Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 40A Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution 3 Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat , 00, 40, 80, 30 KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. PB is installed when Code = Q. These Power Blocks are used on RPS and RDT units. RFS units use the following: 75A p/n Lug p/n ; 30A p/n Lug p/n ; 40A p/n Lug ; 760A p/n Lug p/n Not shown on diagram. 4 For units built /7 contact Daikin Applied with model and serial number to ensure correct part(s) are identified. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 94

195 Section N- Main Control Box Power Panel: (04/3 & Later)- Components, Continued Power Panel- Power Blocks continued, Receptacle, Plugs Sch. Part Part Voltage Sym. Description Number 08V 30V Power Blocks, continued PB0 Power Block- Supply Fan 9 Code 5= F PB0 Power Block- Return Fan 9 Code 5= F Receptacle REC Receptacle Plugs 4 Pin Plug varies varies varies varies 3 6 Pin Plug varies varies varies varies 4 Pin Plug varies varies varies varies 5 3 Pin Cap Kit varies varies varies varies 6 6 Pin Cap Kit varies varies varies varies 7 9 Pin Cap Kit varies varies varies varies 8 5 Pin Cap Kit varies varies varies varies All possible Plugs used are listed. Check actual unit to verify which Plug is required. Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 3 Used with Strain Relief (p/n ) & 6 Pin Cap Kit (p/n ). Used for PL0, PL. 4 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 5 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. 9 Not shown on diagram. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 95

196 Section N- Main Control Box Power Panel: (04/3 & Later)- Components, Continued Power Panel- Disconnect Switch DS, Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS, Disconnect Switch- Main, RAF & SAF Switch- 00A Handle 9340 Shaft Switch- 50A Handle 9340 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Switch- 800A Handle Mechanism Shaft Lugs Switch- 000A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed switch to verify the correct Disconnect size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. This shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 96

197 Section N- Main Control Box Power Panel: (04/3 & Later) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Diagrams Phase Barrier Front Mtd. Aux. Contact 3E MMP 3 Phase Barrier Front Mtd. Aux. Contact 3E MMP 3 MMP 3 Link 3B Contactor Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact 3B Link Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 460/ 7.5 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 08/30V 7.5 HP Motors- 08/30/ 0 HP Motors- All Voltages 5, 0 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 08/30/ 0, 40 HP Motors- 5, 30 HP Motor- 460/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier 3E Front Mtd. Aux. Contact MMP 3 3 Circuit Breaker (not shown) Link 3B Contactor Terminal Block 4A Contactor 4 Overload MMP0 & M0 Link Detail MMP0 & M0 Link Detail 0, 5, 30 HP Motors- 08/30V 40 HP Motors- 50, 60 HP Motors- 460/ 75 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 40, 50, 60 HP Motors- 08/30V 75 HP Motors- Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 97

198 Section N- Main Control Box Power Panel: (04/3 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components 5 HP Motor- Code OR 3= J*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan Cover/Puller N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V 7.5 HP Motor- Code OR 3= K*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 35A Fuse- Supply OR Return Fan 5A Fuse Cover Fuse Cover/Puller N/S= Not Shown on Diagram. All quantities are PER assembly. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 4 pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 98

199 Section N- Main Control Box Power Panel: (04/3 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code OR 3= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link E Phase Barrier N/S AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 50A Fuse- Supply OR Return Fan 45A Fuse- Supply OR Return Fan 0A Fuse Cover Fuse Cover/Puller N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 99

200 Section N- Main Control Box Power Panel: (04/3 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code OR 3= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 0A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 70A Fuse- Supply OR Return Fan 60A Fuse- Supply OR Return Fan 30A Fuse Cover Fuse Cover Fuse Cover/Puller N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 00

201 Section N- Main Control Box Power Panel: (04/3 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code OR 3= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link Link E Phase Barrier Phase Barrier N/S AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 70A Circuit Breaker- Supply OR Return Fan 60A Circuit Breaker- Supply OR Return Fan 30A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 40A Fuse Cover N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 08V 30V 5 HP Motor- Code OR 3= P*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link Link Link E Phase Barrier AFD0, 0 VFD CB0, 0 Circuit Breaker- Supply OR Return Fan 90A Circuit Breaker- Supply OR Return Fan 80A Circuit Breaker- Supply OR Return Fan 40A N/S FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 50A Fuse Cover N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

202 Section N- Main Control Box Power Panel: (04/3 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 30 HP Motor- Code OR 3= Q*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link Link Link E Phase Barrier N/S AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A Circuit Breaker- Supply OR Return Fan 90A Circuit Breaker- Supply OR Return Fan 40A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 60A Fuse Cover N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 08V 30V 40 HP Motor- Code OR 3= R*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 Circuit Breaker 50A MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link Link C Lugs- MMP (kit of 3pc.) E Phase Barrier OL0, 0 Overload 50-00A A Terminal Block AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 50A Circuit Breaker- Supply OR Return Fan 5A Circuit Breaker- Supply OR Return Fan 60A Circuit Breaker- Supply OR Return Fan 50A N/S Lugs- (kit of 3pc.) N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

203 Section N- Main Control Box Power Panel: (04/3 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 50 HP Motor- Code OR 3= S*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 Circuit Breaker 50A MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Phase Barrier OL0, 0 Overload 50-00A A Terminal Block N/S AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 80A Circuit Breaker- Supply OR Return Fan 60A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 75A N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 08V 30V 60 HP Motor- Code OR 3= T*Y Voltage 3 Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Aux. Contact- NC OR NO MMP0, 0 Circuit Breaker 5A MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Phase Barrier OL0, 0 Overload 50-00A A Terminal Block AFD0, 0 VFD N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 90A Circuit Breaker- Supply OR Return Fan 80A FB0, 0 Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 300A N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 3 Note that 60HP motors are not available for Return Air Fans in 08/30V. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 03

204 Section N- Main Control Box Power Panel: (04/3 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 75 HP Motor- Code 3= U*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Aux. Contact- NC OR NO MMP0 Circuit Breaker- Supply Fan 50A Motor Protector-Supply Fan B Link E Phase Barrier OL0 Overload- Supply Fan 80-00A A Terminal Block N/S AFD0, 0 VFD N/S CB0 Circuit Breaker- Supply Fan 5A FB0 Fuseblock- Supply Fan Fuse - Supply Fan 5A N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. Note that 75HP motors are not available for Supply Air Fans in 08/30V and are not available at all for Return Air Fans. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 04

205 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 080, 08D MMP Front Mtd. Aux. Contact 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor 3 MMP Link 3B 3A Contactor Spacer MMP- 6 & M- 6 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail Front Mtd. Aux. Contact 3B Link Contactor A Front Mtd. Aux. Contact MMP- 6 & M- 6 Contactor Link Detail 080, 08 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 65A Contactor- Compressor 3A Contactor- Compressor 5A A Front Mounted Contact- NO- NC Compressor MMP s & Parts Front Mounted Contact- NO- NC Front Mounted Contact- NO- NC MMP- 6 Motor Protector- Compressor 45-63A Motor Protector- Compressor 7- A Motor Protector- Compressor 4-0A B Link Link Link N/S Busbar, 3 position Busbar, 3 position N/S Busbar Top Feed Busbar Top Feed N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 05

206 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 085 thru 09D Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor MMP- 6 & M- 6 Contactor Link Detail 08/30V Front Mtd. Aux. Contact A 3B Contactor Link MMP- 6 & M- 6 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 5A A Front Mounted Contact- NO- NC Compressor MMP s & Parts Front Mounted Contact- NO- NC MMP- 6 Motor Protector- Compressor 45-63A Motor Protector- Compressor - 3A Motor Protector- Compressor 8-5A B Link Link N/S Busbar, 3 position N/S Busbar Top Feed N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 06

207 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 00, 0D, Circuit # Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor MMP, 3, 5 & M, 3, 5 Contactor Link Detail 08/30V- Cir. # Front Mtd. Aux. Contact A 3B Contactor Link MMP, 3, 5 & M, 3, 5 Contactor Link Detail 460/- Cir. # 00, 0 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor, Cir # 65A Contactor- Compressor, Cir # 40A Contactor- Compressor, Cir # 5A A Front Mounted Contact- NO- NC, Cir # Compressor, Cir # MMP s & Parts Front Mounted Contact- NO- NC, Cir # MMP, 3, 5 Motor Protector- Compressor, Cir # 45-63A Motor Protector- Compressor, Cir # - 3A Motor Protector- Compressor, Cir # 8-5A B Link, Cir # Link, Cir # N/S Busbar, 3 position, Cir # N/S Busbar Top Feed, Cir # N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 07

208 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 00, 0D, Circuit # Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor Front Mtd. Aux. Contact A 3B Contactor Link MMP, 4, 6 & M, 4, 6 Contactor Link Detail 08/30V- Cir # MMP, 4, 6 & M, 4, 6 Contactor Link Detail 460/- Cir # 00, 0 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 4, 6 Contactor- Compressor, Cir # 65A Contactor- Compressor, Cir # 40A Contactor- Compressor, Cir # 3A A Front Mounted Contact- NO- NC, Cir # Compressor, MMP s & Parts Front Mounted Contact- NO- NC, Cir # MMP, 4, 6 Motor Protector- Compressor, Cir # 57-75A Motor Protector- Compressor, Cir # 45-63A Motor Protector- Compressor, Cir # - 3A B Link, Cir # Link, Cir # N/S Busbar, 3 position, Cir # N/S Busbar Top Feed, Cir # N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 08

209 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 05, 0D Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor Front Mtd. Aux. Contact A 3B Contactor Link MMP- 6 & M- 6 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail 460/ 05, 0 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 3A A Front Mounted Contact- NO- NC Compressor, MMP s & Parts Front Mounted Contact- NO- NC MMP- 6 Motor Protector- Compressor 57-75A Motor Protector- Compressor 45-63A Motor Protector- Compressor - 3A B Link Link N/S Busbar, 3 position N/S Busbar Top Feed N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 09

210 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 0D, Circuit # Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor Front Mtd. Aux. Contact A 3B Contactor Link MMP, 3, 5 & M, 3, 5 Contactor Link Detail 08/30V- Cir # MMP, 3, 5 & M, 3, 5 Contactor Link Detail 460/- Cir # Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor, Cir # 65A Contactor- Compressor, Cir # 40A Contactor- Compressor, Cir # 3A A Front Mounted Contact- NO- NC, Cir # Compressor, MMP s & Parts Front Mounted Contact- NO- NC, Cir # MMP, 3, 5 Motor Protector- Compressor, Cir # 57-75A Motor Protector- Compressor, Cir # 45-63A Motor Protector- Compressor, Cir # - 3A B Link, Cir # Link, Cir # N/S Busbar, 3 position, Cir # N/S Busbar Top Feed, Cir # N/S= Not Shown on Diagram. 08V 0 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 0

211 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 0D, Circuit # Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor Front Mtd. Aux. Contact A 3B Contactor Link MMP, 4, 6 & M, 4, 6 Contactor Link Detail 08/30V- Cir # MMP, 4, 6 & M, 4, 6 Contactor Link Detail 460/- Cir # Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 4, 6 Contactor- Compressor, Cir # 95A Contactor- Compressor, Cir # 40A Contactor- Compressor, Cir # 3A A Front Mounted Contact- NO- NC, Cir # Compressor, MMP s & Parts Front Mounted Contact- NO- NC, Cir # MMP, 4, 6 Motor Protector- Compressor, Cir # 70-90A Motor Protector- Compressor, Cir # 8-40A Motor Protector- Compressor, Cir # - 3A B Link, Cir # Link, Cir # N/S Busbar, 3 position, Cir # N/S Busbar Top Feed, Cir # N/S= Not Shown on Diagram. 08V 0 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

212 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 5, 30D Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor Front Mtd. Aux. Contact A 3B Contactor Link MMP- 6 & M- 6 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail 460/ 5, 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 95A Contactor- Compressor 40A Contactor- Compressor 3A A Front Mounted Contact- NO- NC Compressor, MMP s & Parts Front Mounted Contact- NO- NC MMP- 6 Motor Protector- Compressor 70-90A Motor Protector- Compressor 8-40A Motor Protector- Compressor - 3A B Link Link N/S Busbar, 3 position N/S Busbar Top Feed N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page

213 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 40D, Circuit # Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor Front Mtd. Aux. Contact A 3B Contactor Link MMP, 3, 5 & M, 3, 5 Contactor Link Detail 08/30V- Cir # MMP, 3, 5 & M, 3, 5 Contactor Link Detail 460/- Cir # Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor 95A Contactor- Compressor 40A Contactor- Compressor 3A A Front Mounted Contact- NO- NC Compressor, MMP s & Parts Front Mounted Contact- NO- NC MMP, 3, 5 Motor Protector- Compressor 70-90A Motor Protector- Compressor 8-40A Motor Protector- Compressor - 3A B Link Link N/S Busbar, 3 position N/S Busbar Top Feed N/S= Not Shown on Diagram. 08V 40 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 3

214 Section N- Main Control Box Power Panel: (04/3 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 40D, Circuit # Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor Front Mtd. Aux. Contact A 3B Contactor Link MMP, 4, 6 & M, 4, 6 Contactor Link Detail 08/30V- Cir # MMP, 4, 6 & M, 4, 6 Contactor Link Detail 460/- Cir # Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 4, 6 Contactor- Compressor, Cir # 95A Contactor- Compressor, Cir # 50A Contactor- Compressor, Cir # 40A A Front Mounted Contact- NO- NC, Cir # Compressor, MMP s & Parts Front Mounted Contact- NO- NC, Cir # MMP, 4, 6 Motor Protector- Compressor, Cir # 80-00A Motor Protector- Compressor, Cir # 40-50A Motor Protector- Compressor, Cir # 8-40A B Link, Cir # Link, Cir # N/S Busbar, 3 position, Cir # N/S Busbar Top Feed, Cir # N/S= Not Shown on Diagram. 08V 40 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 4

215 Section N- Main Control Box Power Panel: (04/3 & Later) Condenser Fan Contactors, MMPs, & Fusing Fantrol Units (Code 47=, ) 8 Link 7B 7 Contactor 080, , , , 0 0, 0 Ref. Sch. Part Part No. Symbol Description Number Fan Contactors 7 M- 6 Contactor Fan MMP s 8 MMP- 3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector MMP5 Motor Protector Motor Protector Motor Protector Motor Protector MMP6 Motor Protector Motor Protector Motor Protector Motor Protector MMP- 3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector MMP5 Motor Protector Motor Protector Motor Protector Motor Protector MMP6 Motor Protector Motor Protector Motor Protector Motor Protector V 30V 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 5

216 Ref. Sch. Part Part Section N- Main Control Box Power Panel: (04/3 & Later) Condenser Fan Contactors, MMPs, & Fusing Fantrol Units (Code 47=, ), Continued 080, , , , 0 0, 0 08V 30V 08V 30V 08V 30V 08V No. Symbol Description Number Fan MMP Parts 7B Link- MMP N/S Bus Bar, Position N/S Bus Bar, 3 Position N/S Bus Bar, 4 Position N/S Bus Bar, 5 Position N/S Bus Bar Top Feed N/S= Not Shown on Diagram. 30V 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 6

217 Section N- Main Control Box Power Panel: (04/3 & Later) Condenser Fan Contactors, MMPs, & Fusing Speedtrol Units (Code 47=, 4) 8 MMP Fuse Block 9 Link 7B 7 Contactor MMP & Contactor Detail Puller 9B 9A Fuse Speedtrol Fusing Detail 080, , , , 0 0, 0 Ref. Sch. Part Part No. Symbol Description Number Fan Contactors 7 M- 6 Contactor Fan MMP s 8 MMP- 3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector MMP5 Motor Protector Motor Protector Motor Protector Motor Protector MMP6 Motor Protector Motor Protector Motor Protector Motor Protector MMP- 3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector MMP5 Motor Protector Motor Protector Motor Protector Motor Protector MMP6 Motor Protector Motor Protector Motor Protector Motor Protector V 30V 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 7

218 Ref. Sch. Part Part Section N- Main Control Box Power Panel: (04/3 & Later) Condenser Fan Contactors, MMPs, & Fusing Speedtrol Units (Code 47=, 4), Continued 080, , , , 0 0, 0 08V 30V 08V 30V 08V 30V 08V No. Symbol Description Number Fan MMP Parts 7B Link- MMP N/S Bus Bar, Position N/S Bus Bar, 3 Position N/S Bus Bar, 4 Position N/S Bus Bar, 5 Position N/S Bus Bar Top Feed Speedtrol Fusing 9 F, Fuse Block B Fuse Cover/Puller A F, Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol N/S= Not Shown on Diagram. 30V 08V 30V Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 8

219 Section N- Main Control Box Intelligent Equipment: Code 3= ****A, ****L (Mid 0 & Later) Intelligent Equipment from Daikin Applied (Code 3= ****A) is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation. A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality IE Express (Code 3= ****L) connects directly to your Daikin unit and offers a low cost, easy to install, entry-level solution to cloud equipment controls for those who don t need the Energy Management Module (EMM) found in the Intelligent Equipment offering. Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply. Click on this link to access the RPL for Intelligent Equipment: Rooftop Std. Cmpr. Units: RCS,RDT,RFS,RPS D Rev. AR 05/8 RPL / Page 9

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W Replacement Parts List No. 70005300 Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT 045-074 Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor,

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70003700 Revision U 07/2 Roofpak Applied Rooftop Units RPS, RDT, RFS, RCS Sizes 045-079 Tons Vintage D R40a To find your Daikin McQuay Parts distributor, call -800-377-2787 or

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017 Replacement Parts List No. 110502600 Revision I 09/2017 McQuay Superpak Applied Rooftop Units RRS, RSS 018-071 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019 Replacement Parts List No. 700052600 Revision G 0/209 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

RoofPak Applied Rooftop Systems Air Handler

RoofPak Applied Rooftop Systems Air Handler Installation and Maintenance Manual IM 987 RoofPak Applied Rooftop Systems Air Handler Group: Applied Air Systems Part Number: IM 987 Date: May 009 RAH 047C - 077C,,000 to 50,000 cfm RDS 800C - 80C, 4000

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information