Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Size: px
Start display at page:

Download "Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D"

Transcription

1 Replacement Parts List No Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS Vintage D Code 44= R, D To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 6 Nomenclature Unit Model and Serial Number... 7 Unit Code Index Unit Layout Diagrams... 5, 6 Electrical Legend Section A- Outdoor/Return/Economizer Air Section Notes... 00% Outside Air Damper with Hood No Return Air Plenum: Code 0= AE, AY AND Code 9= YY... 00% Outside Air Damper with Hood: Code 0= AE, AY AND Code 9= YY % Outside Air Section Damper: Code 0= BE, BY AND Code 9= BY, HY % Economizer Section with Barometric Exhaust Damper- Units without Return Air Fans % Economizer Section with Exhaust Damper- Units with 5" Forward Curved Return Air Fans % Economizer Section with Exhaust Damper- Units with 30" Air Foil Return Air Fans % Economizer Section with Exhaust Damper- Units with 40" Air Foil Return Air Fans % Economizer Assembly Diagrams % Economizer Assembly Components California Title 4 Assembly: Code 33 (Mid 0 & Later) = *F***... 3 Return Air Plenum Isolation Damper with Actuator ACT6... 3, 33 Design Flow Return Air Fan Mounting- 5" Forward Curved Fan Return Air Fan Mounting- 30" and 40" Airfoil Fan Rubber in Shear Components, Spring Mount Diagram Return Air Fan Mounting- 30" Spring and Seismic Mount Components: Code = 30B, 30B Return Air Fan Mounting- 40" Spring and Seismic Mount Components: Code = 40B, 40B Return Air Fan Deck- 5" Fans: Code = 5F, 5F, 5F Return Air Fan Deck- 30" Fans: Code = 30B, 30B, 30B Return Air Fan Deck- 40" Fans: Code = 40B, 40B, 40B Return Air Fan Motors & Motor Mounts... 4, 43 Section Mounted Controls- OAE, RAE, LT, S, REC Section A- Outdoor/Return Air w/ Heat Recovery Section Notes % Outside Air Low Flow: Code 0= E % Outside Air High Flow: Code 0= E Economizer: Code 0= 3E " Return Fan Detail- Fan Components... 49, 50 4" Return Fan Detail- Fan Mounts... 5, 5 Low Leak Damper Detail- Outdoor/Return ACT3, Low Leak Bypass Damper Detail- Economizer ACT Heat Recovery/Enthalpy Wheel VFD60 Frost Protection Inverter: Code 4= F Section Mounted Controls- OAE, RAE, RAT, EAT, LAT Section Mounted Controls- SD, HUM, LT, S, REC Section B- DrawThru Filter/Blank Section Notes Air Blender Section Mounted Controls- PC Filter Section & Magnehelic Differential Pressure Gauge Section C- DrawThru Blank Access Section or Separate Inverter Section Notes... 6 Section D- DrawThru Cooling Section Notes... 6 Evaporator Coil Drain Pans and Gaskets- Unit Sizes D Evaporator Coils- Unit Sizes D Section E- DrawThru Blank Access Section Notes Section Mounted Controls- LT7, REC7, S Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

3 Contents, Continued Section F- Supply Air Section Notes DrawThru Evaporator Coil Drain Pans and Gaskets- Unit Sizes 05-03D Evaporator Coils- Unit Sizes 05-03D Fan Assembly 5" X 6" and 5" X 5" Forward Curved Fans- Unit Sizes 05-03D Fan Assembly 0" Airfoil Fans- Unit Sizes 05-03D Fan Assembly 4" Forward Curved LP Fans- Unit Sizes D... 7 Fan Assembly- 4" Airfoil Fans- Unit Sizes D... 7 Supply Air Fan Mounting- 5" X 6": Code 3= 06F, 06F, 06F Supply Air Fan Mounting- 5" X 5": Code 3= 5F, 5F, 5F Supply Air Fan Mounting- 0" Airfoil Fan: Code 3= 0A, 0A, 0A Supply Air Fan Mounting- 4" Airfoil Fan: Code 3= 4A, 4A, 4A Supply Air Fan Mounting- 4" Forward Curved Fan: Code 3= 4F, 4F, 4F Supply Fan Motors... 78, 79 Inverter & Inverter Bypass Control Box- Motor HP - 5 (03/03 & Earlier)... 80, 8 Inverter & Inverter Bypass Control Box- Motor HP - 5 (4/03 & Later)... 8, 83 Inverter & Inverter Bypass Control Box- Motor HP (03/03 & Earlier) Inverter & Inverter Bypass Control Box- Motor HP (4/03 & Later) Inverters (VFD/AFDs) Section Mounted Controls- PC7, EFT, HL, LT0, S0, REC0, UV Lights Section G- BlowThru Heat Section Notes Option - Blank/Empty Section: Code 04= Y Diffusers Option - Hot Water OR Steam Heating Coil: Code 04= W, S Coils and Coil Compartment Components Valves: Code 04= W, S AND Code 34= W****E, S****E Option 3- Electric Heat: Code 04= E Diffusers, High Limit HL4, HL4 & HL Electric Heating Assemblies and Elements Electric Heat Control Box- No Controls Diagram... 0 Electric Heat Control Box- No Controls Components Electric Heat Control Box- MicroTech III Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules- 00, 50 MBH Furnaces Heat Exchangers & Vestibules- 30, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces... 0 Modulating Burner- Burner Box, Pilot Valve, Pressure Regulator Diagram... Modulating Burner- Components..., 3 Hi Turn Down Burner- Diagram... 4 Hi Turn Down Burner- Components Modulating Burner Controls- No Controls: Code = YC, YM- Diagram... 8 Modulating Burner Controls- No Controls: Code = YC, YM- Components... 9 Modulating Burner Controls- MicroTech III: Code = *E, *F, *W... 0 Hi Turn Down Burner Controls- No Controls: Code = YC, YM- Diagram... Hi Turn Down Burner Controls- No Controls: Code = YC, YM- Components... Hi Turn Down Burner Controls- MicroTech III: Code = *E, *F, *W... 3 Gas Train Inlet- Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train Inlet- Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*... 5 Gas Train Controls- Modulating Burner: Code 34= ****E*, ****R*, ****S* (GV, GV3)... 6 Gas Train Controls- Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* (GV, GV, GV4, GV5, GV6)... 7 Gas Train Outlet... 8 Gas Train Damper Linkage- Modulating Burners / VM Actuator: Code 34= ****E*, ****R*, ****S*... 9 Cabinet Doors, Gasketing, Hardware & Flue Box Mounting: Code 34= 00***, 05*** Cabinet Doors, Gasketing, Hardware & Flue Box Mounting: Code 34= 03*** thru 00***... 3 Section H- BlowThru Heat Blank Access Section Notes... 3 Access Door Latching Assemblies, Key, & Lock (All Sections)... 3 Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

4 Contents, Continued Section I- BlowThru Cooling Section Notes BlowThru Evaporator Coil Drain Pans and Gaskets- Unit Sizes D Evaporator Coils- Unit Sizes D Section J- Final Filter Section Notes Section Mounted Controls- HL3, PC6, SPS Filter Frame, Filter Gaskets, Filters Section K- Discharge Plenum Section Notes Section Mounted Controls- OAT, DAT, SD Damper Assembly- w/ Actuator ACT Section L- Out-of-Airstream Blank Access Section Notes Section Mounted Controls- LT0, S0, REC Section M- Condenser Section Notes... 4, 4 Fan Deck, Coil Guard Diagrams- Unit Sizes 05-06D Fan Deck, Coil Guard Diagrams- Unit Sizes D Standard Condenser Fan Components: Code 47=, Quiet Fan Assembly: Code 47= 3, Standard OR Digital Compressors Circuit #... 47, 48 Standard Scroll Compressors Circuit #... 49, 50 Standard Scroll Compressor Crankcase Heaters & Compressor Mounting... 5 Digital Scroll Compressors Circuit # & Crankcase Heaters... 5 Digital Scroll Compressor Components & T, T3 Transformers/Fusing- CDT, SV Condenser Coils, Pressure Controls, Coil & Vandal Guards... 54, 55 Pressure Controls- AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 (RPS units Only)... 56, 57 Pressure Controls- Manifold Mounted HP, HP, LP, LP, SPTRL (RCS Units Only) Pressure Controls- Manifold Mounted, Digital Compressor Units- HP, HP, LP, LP, SPTRL Condenser Control Box- No Controls, Diagrams (RCS Units Only) Condenser Control Box- MicroTech III Controls Diagram (RCS Units Only)... 6 Condenser Control Box- Components (RCS Units Only)... 6, 63 Control Box- Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C Section N- Main Control Box Notes... 65, 66 Control Box Component Label Diagram Control Panel Units with No Controller: Code = Y*- Diagram Units with No Controller: Code = Y*- Components Control Panel (03/03 & Earlier) MicroTech III Units with Controller: Code = *E, *F, *W- Diagram MicroTech III Units with Controller: Code = *E, *F, *W- Components... 7, 7 Control Panel: (04/03 & Later) MicroTech III Units with Controller: Code = *E, *F, *W- Diagram MicroTech III Units with Controller: Code = *E, *F, *W- Components... 74, 75 Power Panel (03/03 & Earlier) Power Panel Diagram Terminal Blocks, T Transformer, Fuses Fuses, Ground Fault Protection, Phase Protection (PVM, ), Power Supply, Power Blocks Disconnect Switches, Plugs Circuit Breakers Supply MMP0 & M0 Fan Contactor, Return MMP0 & M0 Fan Contactor Diagrams... 8 Supply MMP0 & M0 Fan Contactor, Return MMP0 & M0 Fan Contactor Components Compressor MMP, MMP and Contactor M, M- Unit Size Compressor MMP,, 4 and Contactor M,, 4- Unit Sizes Compressor MMP thru 4 and Contactor M thru 4- Unit Sizes D Condenser Fan Contactors, MMPs, & Fusing... 89, 90 Energy Recovery Wheel MMP60, 6 & Contactor M60, 6: Code 4= Y... 9 Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

5 Contents, Continued Section N- Main Control Box, Continued Power Panel (04/03 & Later) Power Panel Diagram... 9 Terminal Blocks, T Transformer, Fuses Fuses, Ground Fault Protection, Phase Protection (PVM, ), Power Supply, Power Blocks Disconnect Switches, Plugs Supply MMP0 & M0 Fan Contactor, Return MMP0 & M0 Fan Contactor Diagrams...96 Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components Compressor Motor Protector MMP- 4, & Contactor M- 4 Diagrams Unit Sizes 05, 06D Unit Sizes 00-03D... 05, 06 Unit Sizes D Condenser Fan Contactors, MMPs, & Fusing... 08, 09 Energy Recovery Wheel Contactors, MMPs, & Fusing... 0 Intelligent Equipment... Section O- Refrigeration Tubing Notes... Refrigeration Tubing Diagrams..., 3 Valves, Filter Driers, Sight Glasses, & Hot Gas Bypass/Liquid Line Kits... 4, 5 Hot Gas Reheat... 6 Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

6 Parts List Revision History Rev. Date Description A- AF 05/6 Archived Revisions A thru AI. AJ 06/7 Page 8, 9: Updated coding/footnotes. Page 4: Added footnote # and footnote notation. Page 7-0: Added misc. descriptions to Legend. Page 5: Rewrote pg. Header. Updated p/n table. Rewrote/added to footnotes. Page 30: Corrected Ref # description & p/n. Corrected table coding. Page 44, 56, 57: Rewrote footnote #. Page 55: Corrected Ref # 6 Motor p/ns. Page 58: Added /7 & Later HUM components. Page 60: Rewrote gauge table header. Page 59, 6, 4, 6, 06 (OLD) 59, 6, 4, 65, (NEW): Rewrote Notes. Page 9: Rewrote footnote #. Page 08, 0: Added footnote #. Page 9,, 3: Added to Ref #34 TB p/ns. & updated qtys. Added footnote #. Page 3: Rewrote footnote #. Rewrote Ref # 0, 0 descriptions. Page 40: Added Section Mtd. Controls. Updated the TOC. Page 4 (NEW): Added pg. for additional Notes. Repaginated the form & updated the TOC. Page 4, 43 (OLD) 43, 44 (NEW): Updated dwgs. Page 44, 45 (OLD) 45, 46 (NEW): Updated/reorganized table & p/ns. Rewrote footnotes. Page 46-5 (OLD) 47-5 (NEW): Added footnotes and footnote notation as needed. Rewrote pg. headers. Page 5, 53, 59 (NEW): Added pgs. for Digital Scroll components. Repaginated the form & updated the TOC. Page 56 (OLD) 60 (NEW): Rewrote footnote. Rewrote pg. & dwg. headers. Page 57 (OLD) 6 (NEW): Deleted TD, & T from dwg. (RCS No Controls only.) Page 58 (OLD) 6 (NEW): Misc. updates. Page 66 (NEW): Added pg. for additional Notes. Repaginated the form & updated the TOC. Page 64 (OLD) 69 (NEW): Misc. updates/additions. Page 66, 69 (OLD) 7, 74 (NEW): Added MTIII Remote Keypad & Remote Interface p/ns. Page 67, 70 (OLD) 7, 75 (NEW): Moved Remote Interface p/n to Pgs. 66, 69. Page 68, 7 (OLD) 7, 75 (NEW): Added SHS info. Updated/corrected R63 p/ns. Page 69 (OLD) 74 (NEW): Added Transducer Snubber & DCC p/ns. Page 70 (OLD) 75 (NEW): Added misc. relay and TB p/ns. Page 74 (OLD) 79 (NEW): Rewrote footnotes. Page 90 (NEW): Added pg. for additional Cond. Fan components. Repaginated the form & updated the TOC. Page 87 (OLD) 93 (NEW): Updated T Trans. & component p/ns. Page 89 (OLD) 95 (NEW): Rewrote footnote #. Page (OLD) (NEW): Misc. updates/additions. Page 05 (OLD) (NEW): Rewrote notes for IE. Added coding to pg. header & updated the dwg. Page 07, 08 (OLD) 3, 4 (NEW): Added/rewrote footnotes. Updated HGBP p/ns & descriptions. Rewrote pg. header. Updated the TOC. Page 09 (OLD) 5 (NEW): Deleted footnote #. N/S Sensor is p/n: "367904". AK 08/7 Page 3, 4: Added Check Valve p/ns. Page 5: Added E-Coated coil p/n. Corrected Ref # 33 Check Vlv. p/n. AL 09/7 Page 9: Updated PB4 description. Page 4, 66: Rewrote Notes. Page 60, 6, 9: Added "Plugs" bub. Page 6: Added /7 & Later PVM components. Updated/corrected Power Block p/ns. Rewrote footnote # 3. Page 78: Updated PVM qty., rewrote pg. header, & updated the TOC. Page 79, 95: Rewrote footnote #. Page 94: Added /7 & Later PVM components, corrected PVM qty., rewrote pg. header, & updated the TOC. AM 0/8 Page 30: Updated dwg. Page 48: Misc. updates/corrections. Page 5: Updated/corrected the CC Heater table. Added footnote # 4. Page 7, 74: Deleted OBS Display. Combined with Remote Keypad AN 05/8 Page 0, 4: Misc. updates. Page 6: Corrected misc. qtys. Page 74, 5: Updated Code 54 coding. Page 78, 94: Corrected Code 7 coding. Page : Rewrote Notes & updated the dwg. Page : Rewrote Notes. Page 3: Added pg. for additional Tubing dwgs. Repaginated the form & updated the TOC. Page 3, 4 (OLD) 4, 5 (NEW): Updated/corrected table & rewrote footnotes. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

7 Nomenclature Unit Model and Serial Number Unit Model Number R P S 05 D A Design Vintage Nominal Capacity (Tons) Ex. 05= 5 Tons Singlezone Unit Unit Configuration P= Heating, mechanical cooling F= Heating, future mechanical cooling C= Condensing section only Heating Medium A= Natural Gas E= Electric S= Steam W= Hot Water Y= None (cooling only) Roofpak: R= Roofpak Applied Rooftop Serial Number Plant Identification Abbreviation FBO = Faribault, MN U= Unit Year of Manufacture 09= 009, 0= 00, = 0, = 0, etc. FBO U Month of Manufacture 0= Jan. 04= Apr. 0= Feb. 05= May 03= Mar. 06= Jun. Serial Number (build sequence) 07= July 08= Aug. 09= Sept. 0= Oct. = Nov. = Dec. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

8 Nomenclature Unit Code Index RPS 05D A W Y EU D 7 AL P LE S 3 CD S0 BY AE 5F EAY Code C Y AB T CYYS 4Z083D YYYYYY BBBBBB 06F LKY 50A WD3E CYYS 4Z083D YYYYYY B B BY Y 4 MB R Y D YYAAY General Options Unit Model Codes that Pertain: 03, 05, 06, 07, , 5, 33, 6-7 (Mid 0 & Later) Auxiliary Controls/Remote Sensors Unit Model Codes that Pertain:, 3, 6, 7, 8 Sections A, A Return/Outside Air/Heat Recovery Options Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier); 4, 58 (Mid 0 & Later) Sections B, C, D, E DrawThru Cooling Sections Section B- Filter Section Unit Model Codes that Pertain: 5, 33 (Mid 0 & Later), 50 (Mid 0 & Later) Section C- DrawThru Blank Access Unit Model Codes that Pertain: 4, 5, 6 Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 7, 8 Section E- DrawThru Blank Access Unit Model Codes that Pertain: 30 Section F- Supply Fan Options Unit Model Codes that Pertain: 3, 3, 33 (Mid 0 & Earlier), 59 (Mid 0 & Later), 4, 5, 49, (all unit sizes) 7, 8 (05-03D only) Sections G, H, I BlowThru Options Section G= BlowThru Heat/Blank Unit Model Codes that Pertain: 04, 34 Section H= BlowThru Blank Access Unit Model Codes that Pertain: 38 Section I- BlowThru Cooling Sections Unit Model Codes that Pertain: 35, 36 Section J- Final Filter Section Unit Model Codes that Pertain: 39 Section K- Discharge Plenum Section Unit Model Codes that Pertain: 40 Section L- Out-of-Airstream Blank Access Section Unit Model Codes that Pertain: 4 Section M- Condenser Section Unit Model Codes that Pertain: 09, 43, 44, 47, 54, 68 Section N- Main Control Panel Unit Model Codes that Pertain: 09,,, 3, 4, 5, 7, 8, 47 and 3, 54, 68 Section O- Refrigeration Tubing Unit Model Codes that Pertain: 45, 46, 48, 54 (Mid 0 & Later), 68 An "X" located in ANY position in a code string (ESPECIALLY Code 50 for units built mid 0 & earlier OR Code 60 for units built 0 & Later) indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). In mid 0 the code structure was changed from a 54 code index to a longer more detailed format. A sample 54 Code version is shown above. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

9 Nomenclature Unit Code Index, Continued Code 03= Cooling Coil Size Y= None S= Small face area coil L= Large face area coil Code 04= Heat Section- Type of Heat Y= No Heat A= Natural Gas Heat B= Propane E= Electric Heat S= Steam Heat W= Hot Water Heat Code 05= Split Unit Y= None F= Split at Fan/Heat Sections Code 06= Insulation and Liners = ", 3/4# with Liners on Doors = ½",.5# with Solid Liners on Doors & Ceilings 3= ½",.5# with Perforated Liners in Plenums, solid elsewhere 4= ½",.5# with Solid Liners on Doors, Ceilings and Floors 5= ½",.5# with Perforated Liners in Plenums, solid elsewhere (including Floor) 6= ½",.5# with Stainless Steel Solid Liners on Doors, Ceilings and Floors Code 07= Approval Agency Listing Digit Y= None E= ETL- USA C= ETL- Canada Digit Y= None U= UL C= ETL Canada with Low Altitude Burner (less than 000 feet) D= ETL Canada with High Altitude Burner (over 000 feet) M= ETL w/ Massachusetts Code Code 08= Main Control Box Location D= Standard (Discharge Plenum) Code 09= Unit Voltage = 08/60/3 9= 30/60/3 7= 460/60/3 37= 575/60/3 Code = Temperature Control Package MicroTech III Digit : Communication Type L= LonWorks B= BACNet w/mstp E= BACNet w/ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit : Control Type E= Discharge Air w/ Static Pressure Control F= Space or Zone Ctl. W= Discharge Air w/ Space Control No Controls YC= No Temperature Controller w/analog gas actuator YM= No Temperature Controller w/floating point control YA, A, A= RCS Standalone unit (see RPL form # for part information) Code 3= Air Flow Controls Y= None = Duct Sensor = Duct Sensors 3= Duct & Space Sensor 4= Space Sensor 5= Duct High Limit Sensor Code 4= Inverters Y= None Separate Section = SA Fan only w/ Bypass = SA & RA Fans w/ Bypass 4= RA Fan only w/ Bypass No Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan w/o Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan w/o Bypass Code 5= Inverter Vendor Y= None A= ABB Inverter B, S= Daikin Applied Inverter G= Graham Inverter Q= Schneider Inverter R= Reliance Inverter F= Field Installed Inverter, MicroTech III controlled Code 0= Starting Option AL= Across-the-Line Code = Field Power Connection and Disconnect Digit : Type of Control P= One Power Block - Complete unit A= One Disconnect - Complete unit C= Two Disconnects - Fans/Controls/Unit R= Two Power Blocks - Elect. Heat/Unit Digit : Disconnect Mechanism Location = Internal = Through the door Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

10 Nomenclature Unit Code Index, Continued Code 6= Smoke Detectors Y= None = Return Air Only = Supply Air Only 3= Supply and Return Air Code 7= Misc. Auxiliary Controls Digit : Control Type Y= None, includes Mechanical Enthalpy when Code 0= DE, EE, FE, GE, 3E C= Differential Enthalpy (Code 0= DE, EE, FE, GE, 3E) Digit : Control Type Y= None F= Freezestat (Steam or HW Heat only) P= Phase Failure G= Ground Fault Protection L= Line Reactors (Inverter w/ separate section only) A= Freezestat & Phase Failure (Steam, HW Heat only) B= Freezestat & Ground Fault (Steam, HW Heat only) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam or HW Heat only) E= Freezestat & Line Reactors (Steam or HW Heat & Inverter w/separate sect. only) H= Phase Failure & Line Reactors (Inverter w/ separate section only) J= Freezestat, Phase Failure & Line Reactors (ST, HW Heat & Inverter w/separate sect. only) K= Ground Fault, Phase Failure & Line Reactors (ST, HW Heat & Inverter w/separate sect. only) Code 8= Misc. Controls/Unit Length A, S, Y = None ( = Air Handler Length [in.]) K, R = Remote Keypad ( = Air Handler Length [in.]) U = Unit Powered Receptacle ( = Air Handler Length [in.]) V = K + U ( = Air Handler Length [in.]) Code 9= Return Air Plenum YY= No section BY= Bottom Return BB= Bottom Return w/ Burglar Bars BE= Bottom Return w/ Isolation damper HY= Back Return Code 0= Outdoor Air Options YY= None AE= 00% Outside air damper w/hood & Actuator AY= 00% Outside air damper w/hood/no Actuator BE= 0-30% Outdoor air section w/actuator BY= 0-30% Outdoor air section w/o Actuator DE= 0-00% Econ. w/barometric exhaust damper w/ Act. DY= 0-00% Econ. w/barometric exhaust damper w/o Act. EE= 0-00% Econ. w/power closure exhaust damper w/ Act. EY= 0-00% Econ. w/power closure exhaust damper w/o Act. FE= same as DE + Design Flow FY= same as DY + Design Flow GE= same as EE + Design Flow GY= same as EY + Design Flow Y= Heat Recovery 00% OA Low Flow w/o Actuator E= Heat Recovery 00% OA Low Flow w/ Actuator Y= Heat Recovery 00% OA High Flow w/o Actuator E= Heat Recovery 00% OA High Flow w/ Actuator 3Y= Heat Recovery Economizer w/o Actuator 3E= Heat Recovery Economizer w/ Actuator Code = Return Air Fan Digits - 3: Fan Size & Wheel Type 5F= 5" X 5" Forward Curved 4B= 4" Airfoil (Heat Recovery only) 30B= 30" Airfoil 40B= 40" Airfoil Digit 4: Fan Isolation type = Rubber-in-shear (RIS) = Spring 3= Spring w/seismic Snubbers Code = Return Air Fan Motor YYY= No Return Fan E E Y Y= None S= W/ Shaft Grounding Kit E= High Eff. ODP motor H= High Eff. Totally-Enclosed motor J= Premium Eff. ODP motor K= Premium Eff. Totally-Enclosed motor E=.0 HP F=.5 HP G=.0 HP H= 3.0 HP J= 5.0 HP K= 7.5 HP L= 0.0 HP M= 5.0 HP N= 0.0 HP Code 3= Return Air Fan Drive Selection (Mid 0 & Earlier) YYYYY= No Return Air Fan A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 3= Miscellaneous Electrical Options (Mid 0 & Later) Digit : UV Lights Y= None U= UV Lights Digit : Plenum/Vestibule Lights Y= None P= Plenum Lights V= Vestibule Lights B= Plenum & Vestibule Lights Digit 3: SpeedTrol, Energy Recover, HGRH VFD Y= None A= ABB B= Daikin Applied Q= Schneider Digit 4: 5V Service Outlet Y= None F= Factory supplied Line Voltage Outlet Digit 5: Power Factor Capacitors / Intelligent Equipment Y= None A= Intelligent Equipment (IE) P= Power Factor Capacitors (RPS only) L= ie Express Code 4= Heat Wheel Frost Protection Y= None F= Frost Protection Inverter (AFD60) Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

11 Nomenclature Unit Code Index, Continued Code 5= DrawThru Filter/Air Blender Section Digit : Section Type A= Angular (" Section) D= Angular with low CFM Blender (" & 5" section) E= Angular with high CFM Blender (" & 5" section) F= Flat (8" Section) G= Flat with low CFM Blender (" & 5" section) H= Flat with high CFM Blender (" & 5" section) B= Blank " section C= Blank 8" section Digit : Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/ Intersept H= Throwaway 85% Efficient D= Cartridge 65% Efficient E= Cartridge 95% Efficient G= Cartridge 65% Efficient w/ Intersept Code 6= Blank DrawThru Section Y= No section A= Blank " Section C, S= Blank 40" Section D, T= Blank 5" Section Code 7= DrawThru Coil Section/Drain Pan Digits - 3: Cooling Type YYY= No section CYY= Cooling unit DYY= Drain Pan only (40" section) GYY= Cooling w/ Hot Gas Reheat (40" section) Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY only) Code 8= Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) 3= 3 Row 4= 4 Row 5= 5 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 9= N/A to RPS, RFS/RCS- Always YYYYYY Code 30= DrawThru Blank Access/Spacer Section YYYYYY= No section AAAAAA= " Blank Access/Spacer section BBBBBB, CCCCC= 40" Blank Access/Spacer section Code 3= Supply Air Fan Digits - 3: Fan Size & Wheel Type 06F= 5" X 6" Forward Curved 5F= 5" X 5" Forward Curved 0A= 0" Airfoil 4F= 4" Forward Curved, Low Pressure 4A= 4" Airfoil Digit 4: Fan Isolation type = Rubber-in-shear (RIS) = Spring 3= Spring w/seismic Snubbers Code 3= Supply Air Fan Motor E E Y Y= None S= W/ Shaft Grounding Kit E= High Eff. ODP motor H= High Eff. Totally Enclosed motor J= Premium Eff. ODP motor K= Premium Eff. Totally Enclosed motor E=.0 HP K= 7.5 HP F=.5 HP L= 0.0 HP G=.0 HP M= 5.0 HP H= 3.0 HP N= 0.0 HP J= 5.0 HP P= 5.0 HP Code 33= Supply Air Fan Drive Selection (Mid 0 & Earlier) A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 33= Miscellaneous Mechanical Options (Mid 0 & Later) Digit : Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DrawThru & Blow- Thru sections Digit : California Title 4 Y= None F= Economizer w/ Fault Detection/Diagnosis (FDD) Digit 3: Ebtron Air Flow Measuring S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold) Digit 4: Heating Coil Options Y= None E= Electrofin Coating Digit 5: Cooling Coil Options Y= None E= Electrofin Coating Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

12 Nomenclature Unit Code Index, Continued Code 34= BlowThru Heat Section YYYYYY= No section (cooling unit only) BBBBBB= Blank 40" section Gas Heat Breakdown: 00 S H A A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position E= Modulating Burner (3:) R= Modulating Burner/with H.P. Regulator Range= -3 psi S= Modulating Burner/with H.P. Regulator Range= 5-0 psi H= Hi Turn Down Burner (0:) T= Hi Turn Down Burner with H.P. Reg. Range= -3 psi U= Hi Turn Down Burner with H.P. Reg. Range= 5-0 psi S= Stainless Steel Heat Exchanger MBH (in 0's) ex. 00= 00 MBH [00,05,03,040,050,064,065,079,080,00] Electric Heat Breakdown: E 00 Y = Stage = Stage 3= 3 Stage Always Y KW (ex. 00= 0 KW) [00,040,060,080,00,0,40,60, 80] E= Electric Heat Hot Water OR Steam Heat Breakdown: W D 3 E Y= No Actuator E= Electric Actuator Y= No Valve = - Way Valve (ST) 3= 3- Way Valve (HW) Y= No Valve D=.00" Valve E=.5" Valve F=.50" Valve G=.00" Valve = 9 FPI Row (HW) or 6 FPI Row (ST) = FPI Row (ST) = 9 FPI Row (HW) W= Hot Water Heat (HW) S= Steam Heat (ST) Code 35= BlowThru Coil Section/Drain Pan Digits - 3: Cooling Type YYY= No section CYY= Cooling unit DYY= Drain Pan only (40" section) GYY= Cooling w/ Hot Gas Reheat (40" section) Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY only) Code 36= Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) 3= 3 Row 4= 4 Row 5= 5 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch 4Z= Type 4EZ Code 37= N/A to RPS, RFS/RCS- Always YYYYYY Code 38= BlowThru Blank Access Section (Mid 0 & Earlier) Y= No section B= Blank Section after Heat Section- 40" section D= Blank Section after Heat Section- 5" section Code 38= Attenuator Section (Mid 0 & Later) Y= No section G= With 36" Std. Straight Attenuator K= With 36" Std. Straight Attenuator w/ Tedlar Coating H= With 60" Std. Straight Attenuator L= With 60" Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating A= Blank " Section C= Blank 40" Section D= Blank 5" Section Code 39= Final Filter Section Y= No section A= Flat filter section, 95% cartridge, 8" section B= Flat filter section, 95% cartridge, 5" section C= Blank- 8" section D= Blank- 5" section E= Flat filter section, 95% cartridge, 8" section with Intersept F= Flat filter section, 95% cartridge, 5" section with Intersept G= Flat filter section, 95% HEPA cartridge, 8" section H= Flat filter section, 95% cartridge, 5" section Code 40= Discharge Air Plenum Digit B= Bottom F= Front (RFS units only) L, S= LH side (opposite drive side) R= RH side (drive side) Digit Y= None B= Burglar Bars E= Isolation Damper w/actuator Code 4= Out-of-Airstream Blank Access Section Y= No section = 40" Section Out Of Airstream Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

13 Nomenclature Unit Code Index, Continued Code 4= Compressor Capacity Control = steps (Size 05 only) 3= 3 steps (Sizes 00-03) 4= 4 steps (Sizes ) M= Modulating Code 43= Condenser Options YY= None (RFS units only) Digit : Air Coils M= 5mm Microchannel Coil P= 5mm Microchannel Electrofin coated Coil T= 3mm Microchannel coil U= 3mm Microchannel Electrofin coated Coil Y= None Digit : Miscellaneous Options G= Coil/Vandal Guards (coated steel) S= Sealtite Conduits B= Coil/Vandal Guards & Sealtite Conduits Y= None Code 44= Compressor Type R= Standard Scroll, R40A D= Digital Scroll, R40A Code 50= Blender Section (Mid 0 & Later) Y= None L= Low CFM Blender, 5 Inch Section H= High CFM Blender, 5 Inch Section A= Blank " Section C= Blank 40" Section D= Blank 5" Section Code 5= Packaging (Mid 0 & Earlier) = Steel Skid = Consolidated Ship Code 5= Draw=Thru Pre-Heat Section (Mid 0 & Later) YYYYY= None AAAAAA= Blank " Section CCCCCC= Blank 40" Section DDDDDD= Blank 5" Section W D 3 E Y= No Actuator E= Electric Actuator Y= No Valve = - Way Valve (ST) 3= 3- Way Valve (HW) Code 45= Compressor Isolation Y= None (RFS units only) = Resilient rubber-in-shear Code 46= Piping Options Y= None = Hot Gas Bypass, Circuit # = Hot Gas Bypass, Circuit # & # 3= Replaceable Core Filter Drier 4= Hot Gas Bypass Circuit # w/replaceable Filter Drier Core 5= Hot Gas Bypass Circuit # & w/replaceable Filter Drier Cores Code 47= Low Ambient Operation Y= None (RFS units only) = FanTrol = SpeedTrol (includes FanTrol) 3= Quiet Fan + FanTrol 4= Quiet Fan + SpeedTrol L= SpeedTrol w/ Inverter Compressor Code 48= IBC Seismic Construction/Hot Gas Reheat Y= None H= Modulating Hot Gas Reheat A= ASCE 7-0 Wind Certification I= Seismic Construction K= Modulating Hot Gas Reheat and Seismic Construction J= IBC Seismic Construction- Category E/F Code 49= Supply and Return Fan Options Y= None A= SA Fan Belt Guard B= SA Fan Section Light C= SA Fan Belt Guard w/ SA Fan Section Light D= SA & RA Fan Belt Guard E= SA & RA Fan Section Light F= SA & RA Fan Belt Guard w/ SA & RA Fan Section Light Code 50= Miscellaneous (Mid 0 & Earlier) YY= None XX= Special Y= No Valve D=.00" Valve E=.5" Valve F=.50" Valve G=.00" Valve = 9 FPI Row (HW) OR 6 FPI Row (ST) = FPI Row (ST) 3= 06 FPI Row (ST) 4= FPI Row (ST) = 9 FPI Row (HW) W= Hot Water Heat (HW) S= Steam Heat (ST) Code 5= Parts Warranty (Mid 0 & Earlier) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 5= Drain Pan/Humidifier Section (Mid 0 & Later) YY= None AA= Blank " Section CC= Blank 40" Section DD= Blank 5" Section DH= Humidifier w/stainless steel Drain Pan 40" section DY= Stainless steel Drain Pan only, 48" section Code 53= Compressor Warranty (Mid 0 & Earlier) Y= None (RFS units only) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Code 53= Custom Specifications (Mid 0 & Later) YY= None RR= "B" vintage replacement unit Note that there are some Digital Scroll Compressor units built as SPECIALS (Code 44= R AND Code 60= XX with Digital Scroll compressors listed as a special feature). Refer to the Condenser Section Notes for more information on Digital Scroll Compressor units. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

14 Nomenclature Unit Code Index, Continued Code 54= Heat Exchanger Warranty (Mid 0 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Code 54= Hot Gas/Liquid Subcool Reheat (Mid 0 & Later) YY= None BM= BlowThru Modulating Hot Gas Cir. # (includes SpeedTrol) ML= Modulating Liquid Subcool Reheat Circuits # & BL= BlowThru Modulating, Hot Gas Circuit #, AND Modulating Liquid Subcool Reheat Circuits # & ) Code 55= Ultra High Efficiency Units YY= None HE= Ultra High Efficiency Unit (06D, 0D, 06D, 03D) Code 56= Chicago Code/Refrigeration Service Valves YY= None CC= Chicago Code YV= Refrigeration Service Valves CV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS, RFS/RCS- Always YY Code 58= Return Air Fan Drive Selection A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 59= Supply Air Fan Drive Selection A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 60= Misc. Specials YY= None XX= Special Code 6= Packaging/ASHRAE Certification = Steel Skid = Consolidated Ship 3= Steel Skid w/ ASHRAE Certification 4= Consolidated Ship w/ ASHRAE Certification Code 64= Heat Exchanger Warranty Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Code 65= Unit Family 07C= 05D- 030D 037C= D Code 66= Drain Connection Y= None L= Left Side (opposite drive side) R= Right Side (drive side) Code 67= ASHRAE Certification Y= None B= AHRI Certified C= AHRI Certified D= AHRI Certified Code 68= Short Circuit Current Rating YY= None 0= 0 SCCR = SCCR 65= 65 SCCR Code 69= Labor Warranty Digit : Unit Labor A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Y= None Z= Special Digit : Compressor Labor A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Y= None Z= Special Codes 70-7 N/A to RPS/RDT/RFS/RCS- Always YYYYYYYY Code 6= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 63= Compressor Warranty Y= None (RFS units only) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

15 Unit Layout Diagrams Unit Section Layout.5" NPT Drain Condenser control panel (RCS only) The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

16 Unit Layout Diagrams Control Location RPS Units shown for reference. Controls and control locations may vary depending on unit configuration, size, and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

17 Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT0, Actuator Motors, Exhaust Dampers Return Air Section ACT, 3 Actuator Motor, Enthalpy Wheel Bypass Damper Energy Recovery Section AS Airflow Switch, Burner Blower Gas Heat Box BM Burner Blower Motor Furnace Section C- C4 Power Factor Capacitors, Compressors Condenser Section C0 Power Factor Capacitors, Supply Fan Supply Air Section C0 Power Factor Capacitors, Return Fan Return Air Section CB0 Circuit Breaker, Supply Fan Main Control Box CB0 Circuit Breaker, Return/Exhaust Fan Main Control Box CB60 Circuit Breaker, Energy Recovery Wheel Main Control Box COMPR- 4 Compressors Condenser Section DAT Discharge Air Temperature Sensor Discharge section DCC Digital Compressor Controller Main Control Box DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS Disconnect, Total Unit or Condenser/Heat Main Control Box DS Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS4 Disconnect, Condenser (RCS only) RCS Control Box DS6 Disconnect, Factory Powered Outlet Condenser Section EAT Exhaust Air Temperature Sensor Energy Recovery Section EFT Entering Fan Air Temperature Sensor Supply Fan Section ERM, Energy Recovery Wheel Motors Energy Recovery Section EXPA, B, C Expansion Boards Main Control Box FA, B Fuses, Control Circuit Transformer, (T) Primary Main Control Box FC Fuse, Control Circuit Transformer, (T) Secondary Main Control Box F Fuse, Control Circuit Transformer, (T) Primary Main Control Box F3 Fuse, Burner Blower Motor Main Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section FA, B Fuses, Digital Compressor Transformers Main Control Box FB0 Fuseblock, Supply Air Fan Main/Cond. Control Box FB,,, Fuseblocks, SpeedTrol Main/Cond. Control Box FB0 Fuseblock, Return Air Fan Main/Cond. Control Box FB3-40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Box FB4-50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Box FB60 Fuseblock, Energy Recovery Wheel Main/Cond. Control Box FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FP, Frost Protection, Refrigeration Circuits Coil Section, Cool FS, Freezestat Control Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Box GFR, Ground Fault Relays Main Control Box GFS, Ground Fault Sensors Main Control Box GFR4 Ground Fault Relay, Condenser Condenser Control Box GFS4 Ground Fault Sensor, Condenser Condenser Control Box GRD Ground All Control Boxes Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

18 Electrical Legend Continued Schematic Sym. Description Location GV Gas Valve, Pilot Furnace Section GV Gas Valve, Main/Safety Furnace Section GV3 Gas Valve, Redundant/Safety Furnace Section GV4-8 Gas Valve, Main, Hi-Turn Down Furnace Section HL - 0 High Limits, Power, Electric Heaters (Top Bank) Electric Heat Section HL - 0 High Limits, Power, Electric Heaters (Bottom Bank) Electric Heat Section HL High Limit, Gas Heat (Prefilters) Supply Air Section HL3 High Limit, Gas Heat (Final Filters) Final Filter Section HL3-40 High Limits, Control, Electric Heaters (Top Bank) Electric Heat Section HL4-50 High Limits, Control, Electric Heaters (Bottom Bank) Electric Heat Section HP- 4 High Pressure Controls, Refrigerant Compr./Press./Cond. Box HP5 High Pressure Control, Gas Furnace Section HS Heat Switch, Electric Shutdown Main Control Box HS3 Heat Switch, Electric Heat Deadfront Interlock Electric Heat Box HTR- 4 Crankcase Heaters On Compressors HUM Humidistat Sensor Energy Recovery Section IT Ignition Transformer Furnace Section LAT Temperature Sensor, Leaving Air Energy Recovery Section LP- 4 Low Pressure Controls, Refrigerant On Compr./Cond. Box LP5 Low Pressure Control, Gas Furnace Section LR0 Line Reactor, Supply Fan Inverter Bypass Box LR0 Line Reactor, Return/Exhaust Fan Inverter Bypass Box LR, Line Reactors, Condenser Fan SpeedTrol Pressure/Cond. Box LS, Limit Switches, Low/High Fire Furnace Section LT0 Light, Supply Fan Supply Air Section LT Light, Return Fan Return Air Section LT Light, Heat Section Heat Section LT3 Light, Filter Section Filter Section LT4 Light, Final Filter Section Final Filter Section LT5 Light, Discharge Section Discharge Section LT6 Light, Blow-through Coil Section BlowThru Coil Section LT7 Light, Evaporator Coil Section Evaporator Coil Section LT8 Light, Preheat Section Preheat Section LT9 Light, Blank Section Blank Section LT0 Light, Blank/Empty Section Blank/Empty Section LT Light, DrawThru Coil Section DrawThru Coil Section LT Light, Condenser Section Condenser Section M-4 Contactors, Compressors Main/Cond. Control Box M0 Contactor, Supply Fan Main Control Box M- 8 Contactors, Condenser Fans, Circuit # Main/Cond. Control Box M0 Contactor, Return Fan Main Control Box M- 8 Contactors, Condenser Fans, Circuit # Main/Cond. Control Box M9 Contactor, Burner Motor Furnace Section M30 Contactor Reversing, Inverter Bypass, Supply Fan Inverter Bypass Box M3-39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Reversing, Inverter Bypass, Return Fan Inverter Bypass Box M4-50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M60, 6 Contactors, Energy Recovery Wheel Motor Main Control Box MCB Microtech III Control Board Main Control Box MJ Mechanical Jumpers All Control Boxes MMP- 4 Manual Motor Protectors, Compressors Main/Cond. Control Box Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

19 Electrical Legend Continued Schematic Sym. Description Location MMP0 Manual Motor Protector, Supply Fan Main Control Box MMP- 8 Manual Motor Protectors, Condenser Fans Ckt. Main/Cond. Control Box MMP0 Manual Motor Protector, Return fan Main Control Box MMP- 8 Manual Motor Protectors, Condenser Fans Ckt. Main/Cond. Control Box MMP30 Manual Motor Protector, Inverter Bypass Supply Fan Inverter Bypass Box MMP40 Manual Motor Protector, Inverter Bypass Return Fan Inverter Bypass Box MMP5-53 Manual Motor Protectors, Exhaust Fan(s) Prop Exhaust Box MMP60, 6 Manual Motor Protector, Energy Recovery Wheel Main Control Box MP- 4 Motor Protectors, Compressors On Compressors OAE Enthalpy Control, Outside Air Economizer Section OAT Temperature Sensor, Outside Air Economizer Section OL6 Overload- Energy Recovery Wheel () Main/Cond. Control Box PB, Power Block, Power Distribution Main Control Box PB3 Power Block, Power Distribution, Electric Heat Electric Heat Section PB4 Power Block, Power Distribution, Condenser (RCS only) Cond. Control Box PB9, 0 Power Blocks, Supply Fan Junction Box, Split Unit PB, Power Blocks, Power Distribution Main Control Box PB9, 0 Power Blocks, Return/Exhaust Fan Junction Box, Split Unit PC5 Pressure Control, Clogged Filter Pre Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Section PC3, 3 Pressure Controls, FanTrol Pressure/Cond. Box PC9 Pressure Control, Coil Splitter Pressure/Cond. Box PT, Pressure Transducers, SpeedTrol Pressure/Cond. Box PVM, Phase Voltage Monitors Main Control Box PVM 4 Phase Voltage Monitor, Condenser Condenser Control Box R- Relays, High Pressure Reset (RCS only) RCS Control Box R5-8 Relays, Safety (RCS only) RCS Control Box R3-36 Relays, Compressor Staging (RCS only) RCS Control Box R Relay, Cond. Fan SpeedTrol Inverter Enable Pressure/Cond. Box R- 4 Relays, FanTrol Condenser Fan Cycling Main/Cond. Control Box R7 Relay, Cond. Fan SpeedTrol Inverter Enable Pressure/Cond. Ctrl. Box R0 Relay, Gas/Steam/Hot Water Furn./Main Ctrl. Box R, Relays, Gas Heat, 0: High Turndown Furn./Main Ctrl. Box R3 Relay, Gas Heat Furnace Section R4 Relay, Gas Heat Alarm Main Control Box R5 Relay, Gas Heat, Start Supply Fan Inverter Main Control Box R6 Relay, Isolation/Exhaust Dampers Main Control Box R8 Relay, Isolation Damper Safety Main Control Box R45 Relay, UV Lights Main Control Box R70-90 Relays, Specials/Digital Compressor Control Box RAE Enthalpy Sensor, Return Air Return Air Section RAT Temperature Sensor, Return Air Return Air Section REC Receptacle, Main Box Main Control Box REC Receptacle, Condenser Box Cond. Control Box REC3 Receptacle, Field Power, 5VAC Discharge Bulkhead REC0-3 Receptacles, Cabinet Sections Cabinet Sections RHB, Interface Board, Modulating Hot Gas Reheat Main Control Box S Switch, System On/Off Main Control Box S Switch, System On/Off, RCS Unit Cond. Control Box S3 Switch, Furnace On/Off Furnace Section Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

20 Electrical Legend Continued Schematic Sym. Description Location S4 Switch, Inverter Bypass On/Off Main Control Box S40-45 Switches, Door Interlock, UV Lights Cabinet Sections SC Speed Control, Circuit # Cond. Bulkhead SC Speed Control, Circuit # Cond. Bulkhead SD Smoke Detector, Supply Air Discharge Section SD Smoke Detector, Return Air Return Air Section SHS Sensor, Space Humidity Return Section (Field inst.) SPS, Sensors, Static Pressure, Duct or Building Main Control Box SV, Solenoid Valves, Liquid/Drop Condenser Section SV7 Solenoid Valve, Digital Compressor Condenser Section T Transformer, Main Control, Line/5VAC Main Control Box T Transformer, Control Input, 5/4VAC Main Control Box T3 Transformer, Control Output, 5/4VAC Main Control Box T6 Transformer, Factory Powered outlet, Line/5VAC Condenser Section T7 Transformer, Hot Gas Reheat, 5/4VAC Main Control Box T Transformer, SpeedTrol, Line/40VAC Condenser Section TB Terminal Block, Internal for Transformers Main Control Box TB Terminal Block, Field Main Control Box TB3 Terminal Block, Factory, 5/4VAC Main Control Box TB4 Terminal Block, Field, 5VAC Main Control Box TB5 Terminal Block, RCS Field, 5V Condenser Control Box TB6 Terminal Block, RCS Field Condenser Control Box TB7 Terminal Block, 5VAC Convenience Outlet Main Control Box TB8 Terminal Block, RCS, 5VAC Convenience Outlet Condenser Control Box TB Terminal Block, Heating Furn./Elect. Heat Ctrl. Box TB5-8 Terminal Blocks, Split Unit Junction Box Split Unit Junction Box TB35, 36 Terminal Blocks, Digital Compressor Main Control Box TC- 4 Temperature Controls, FanTrol Condenser Section TD, Time Delays, Compressor Lockout (RCS only) Condenser Control Box TD0 Time Delay, Return Air Fan Main Control Box TR, Transducer, Pressure, SpeedTrol Main Control Box UV Ultra-Violet Light(s) Coil/Discharge Section VFD/AFD0 Adjustable Frequency Drive, Supply Fan DrawThru/Supply Section VFD/AFD, Adjustable Frequency Drive, Cond. Fan SpeedTrol Pressure/Cond. Ctrl. Box VFD/AFD0 Adjustable Frequency Drive, Return/Exhaust Fan Dr. Thru/Ret./Exh. Section VFD/AFD60 Adjustable Frequency Drive, Energy Recovery Wheel Energy Recovery Section VM Valve Motor #, Heating Furnace/Heating Section VM5 Valve Motor #5, Cooling Coil Section, Cooling VV Vent Valve, Gas Heat Furnace Section ZNT Sensor, Zone Temperature Field Installed Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

21 Section A- Outdoor/Return Air Section Notes Primary Codes that pertain: 9, 0,,, 3 (Mid 0 & Earlier), 58 (Mid 0 & Later) Additional Codes that pertain: 06, 09,, 4, 5, 6, 7, 3 (Mid 0 & Later), 33, 48, 49 Codes 9 and 0 determine the base section. Code 9 is the Return Air Plenum and determines if the unit has back/horizontal return air or bottom return air. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 0= BE, BY, DE, DY, EE, EY, FE, FY, GE, GY). The only case in which a Plenum is not required is when a 00% Outdoor Air Damper and Hood are ordered (Code 0= AE, AY). For units with Heat Recovery (Code 0= *, *, 3*) see Section A. Code determines the Return Fan size and type, Code determines the Motor horsepower and type; and Code 3 (Mid 0 & Earlier) OR 59 (Mid 0 & Later) determine the drive selection. These codes only pertain to units with a 0-00% Economizer (Code 0= DE, DY, EE, EY, FE, FY, GE, GY). The Return Air Fan section parts, the Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 09, unit voltage, is part of the Return Fan Motor part number identification. Code, the control system, comes into play when an Economizer is present. The Economizer is supplied with an Actuator on MicroTech equipped units, but MAY OR MAY NOT come with a factory supplied Actuator if the unit has controls by others (Code = YM, YC). Codes 4 & 5 determine if the unit has a Return Air Fan Inverter/AFD/VFD and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4=, 4 there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller. Code 6 determines if the unit has a Smoke Detector located in the Return Air cabinet. If Code 6=, 3 a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/ HGRH inverter brand specified, and/or the presence of Intelligent Equipment. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Code 33 also indicates if the unit is California Title 4 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Light (Code 49= E), Fan Belt Guards (Code 49= D) or both (Code 49= F). Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

22 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood Code 0= AE, AY AND Code 9= YY No Return Air Plenum 4 SectionB 6 4 Ref. Part With Actuator Without Actuator Qty. No. Description C0= AE C0= AY 4 Damper Assembly Hood Channel This Damper assembly does NOT include an Actuator or Actuator Linkage. A list of component parts follows this page. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

23 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood Code 0= AE, AY AND Code 9= YY Manual Linkage Detail: C0= AY A 7 3A Damper Assy Detail Motorized Linkage Detail: C0= AE 35 Ref. Part Part Number Qty. No. Description C0= AE C0= AY Damper Assy Linkage Rod Crank Arm Operator Not Used 6A Arm Shaft Not Used Linkage Rod Actuator Support Not Used 3 Damper Blade Damper Seal Damper Stop Bearing Support Not Used Linkage Bar Crank Arm Not Used Ball Joint Actuator Motor ACT Not Used 3 Bushing Bushing Gasket Gasket Damper End Plug Damper End Plug Damper End Plug Bearing Not Used 3A Lock Collar Not Used Retainer Bracket Not Used 38 Nut, Hex Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

24 Section A- Outdoor/Return Air Section 0-30% Outside Air Section Damper Code 0= BE, BY AND Code 9= BY, HY 5 3A 34 Linkage Detail: Without Actuator C0= BY Damper Detail 36 3 Linkage Detail: With Actuator C0= BE 9 Ref. Part Part Number Qty. No. Description C0= BE C0= BY Damper Assembly Damper Damper Blade Gasket Gasket End Seal Motor Support Not Used 3A Rod Support Angle Not Used Linkage Bar Shaft Linkage Exhaust Louver N/S Screen Only End Plug End Plug Bushing Bushing Ball Joint Actuator Motor ACT Not Used 36 Damper Crank Arm Not Used 37 Mounting Plate Not Used 4 Screw-.9-4 x Screw-.5-0 x Retainer Not Used N/S= Not shown on diagram. Assembly includes Damper, Damper Linkage, and Actuator (Code 0= BE) OR Damper and Linkage only (Code 0= BY). Damper only, no Linkage or Actuator components. 3 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

25 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units without Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, GE, GY AND Code = YYYY 60 Back Return (Code 9= HY) shown. 00 Ref. Part Part Qty. No. Description Number 00 Economizer Damper Assembly w/ Act.(Code 0= DE, EE, FE, GE, KE) w/o Act. (Code 0= DY, EY, FY, GY, KY) 60 Exhaust Damper & Baffle Assembly Powered (Code 0= EE, EY, GE, GY) Damper Only Barometric (Code 0= DE, DY, FE, FY, KE, KY) Damper Only Economizer Damper ONLY (NO Actuator or Actuator Linkage) p/n detail is three pages after next. For the complete Damper Assembly including Actuator and Linkage contact Daikin Applied with model and serial number information so that the correct assembly can be identified. 3 Includes the Damper, Damper Actuator, and Side Baffles. 4 Includes the Damper, Damper Actuator, and Side Baffles. 5 Includes the Damper and Side Baffles. 6 Damper ONLY. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

26 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units with 5" Forward Curved Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, GE, GY AND Code = 5** Unit Sizes D only Bottom Return (Code 9= BY, BB) shown. Ref. Part Part Qty. No. Description Number 0-00% Economizer Damper Actuator/linkage Assy (C0= DE) Actuator Only Linkage Assy w/o act. (C0= DY) Damper Assy Barometric (C0= DE, DY, FE, FY) Power (C0= EE, EY, GE, GY) Damper Only Gasket Gasket Belt Guard- LH Belt Guard- RH Deflection Screen This Damper assembly does not include an Actuator or Actuator Linkage. A list of component parts is three pages previous to this page. Code 49= D, F. 3 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

27 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units with 30" Air Foil Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, GE, GY AND Code = 30** Bottom Return (Code 9= BY, BB) shown. Ref. Part Part Qty. No. Description Number 0-00% Economizer Damper Actuator/linkage Assy (C0= DE) Actuator Only Linkage Assy w/o act. (C0= DY) Damper Assy Barometric (C0= DE, DY, FE, FY) Power (C0= EE, EY, GE, GY) Damper Only Belt Guard Gasket This Damper assembly does not include an Actuator or Actuator Linkage. A list of component parts is four pages previous to this page. Code 49= D, F. 3 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

28 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units with 40" Air Foil Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, GE, GY AND Code = 40** Unit Sizes D only Bottom Return (Code 9= BY, BB) is only option for 40" RAF. Ref. Part Part Qty. No. Description Number 0-00% Economizer Damper Actuator/linkage Assy (C0= DE) Actuator Only Linkage Assy w/o act. (C0= DY) Damper Assy Barometric (C0= DE, DY, FE, FY) Power (C0= EE, EY, GE, GY) Damper Only Belt Guard Gasket Fan Guard This Damper assembly does not include an Actuator or Actuator Linkage. Code 49= D, F. 3 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

29 Section A- Outdoor/Return Air Section 0-00% Economizer Assembly Code 0= D*, E*, F*, G* 0 Diagrams With Actuator Code 0= DE, EE, FE, GE Without Actuator Code 0= DY, EY, FY, GY A 6A A Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

30 Section A- Outdoor/Return Air Section 0-00% Economizer Assembly Code 0= D*, E*, F*, G* Components Ref. Part Part Number Qty. No. Description C0= *E C0= *Y Damper Assembly Channel Linkage Rod Crank Arm Operator Not Used 6A Arm Shaft Not Used Linkage Rod Bottom Support Top Support Block Off Motor Mount Not Used A Rear Bearing Support Not Used Side Support Damper Blade Outside Seal Center Seal Damper Stop Front Bearing Supp. Not Used Linkage Bar Linkage Bar Crank Arm Not Used Ball Joint Actuator Motor ACT Not Used 3 Bushing Bushing Gasket Gasket End Plug End Plug End Plug Bearing Not Used 3A Locking Collar Not Used Mount Not Used This Damper assembly does not include an Actuator or Actuator Linkage. Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 30

31 Section A- Outdoor/Return Air Section California Title 4 Assembly Code 33 (Mid 0 & Later) = *F*** Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch Bracket, Mounting Switch Switch, Push Button SPDT Bushing, Conduit 3630 Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

32 Section A- Outdoor/Return Air Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE AND Code = 5F* 3 Unit Sizes 05-03D Ref. Part Part Qty. No. Description Number 0 Damper Assembly 4 x 8" w/ ACT Motor Mount Damper Blade Damper Linkage Actuator Motor- ACT Damper Shaft Damper Ball Joint Damper Blade Gasket Retainer Bearing, sleeve flange The Damper Gasket is sold in 0 foot lengths feet required per Blade. Note that the design of the ACT6 mounting components was changed in mid 03. It is recommended that the when replacing the actuator mount that the new design be used. Minor field modifications are required for proper installation and operation. 3 For units with 4" Fans (Code = 4B*) OR 40" Fans (Code = 40B*) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

33 Section A- Outdoor/Return Air Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE AND Code = 30B* Ref. Part Part Qty. No. Description Number 0 Damper Assembly 30 x 76" w/ ACT Motor Mount Damper Blade Damper Linkage Actuator Motor- ACT Damper Shaft Damper Ball Joint Damper Blade Gasket Retainer Bearing, sleeve flange The Damper Gasket is sold in 0 foot lengths feet required per Blade. Note that the design of the ACT6 mounting components was changed in mid 03. It is recommended that the when replacing the actuator mount that the new design be used. Minor field modifications are required for proper installation and operation. 3 For units with 4" Fans (Code = 4B*) OR 40" Fans (Code = 40B*) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 33

34 LH Louvered Door Assy Section Final Assembly Section A- Outdoor/Return Air Section Design Flow Code 0= FE, FY, GE, GY Louvered Door Assembly Detail 3 05 RH Louvered Door Assy Design Flow Vane and Vane Bearings Detail Adjuster Control Assy Detail 30 Spring Detail Ref. Part Part Qty. No. Description Number Louver Panel Units with no Return Fan (40" Door) Left Hand Door Units with no Return Fan (40" Door) Right Hand Door Units with 30" OR 40" Return Fan (5" Door) Left Hand Door Units with 30" OR 40" Return Fan (5" Door) Right Hand Door Grille Units with no Return Fan (40" Door) Units with 30" OR 40" Return Fan (5" Door) Gasket Potentiometer O-Ring- Potentiometer Panel- Vane Shaft- Upper Bearing- Lower Crank Arm Assy Left Hand Door Crank Arm Assy Right Hand Door Link Arm 0 Bearing Bearing Spring- Main Spring- Secondary N/S Leveling Kit- Design Flow P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 34

35 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 5" Forward Curved Fan Code = 5F, 5F, 5F Rubber-In-Shear (RIS) Mount Code = 5F Ref. Part Part Qty. No. Description Number Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 6 Top View 64 Pos. 6 Seismic strap used only when Code = 5F Pos. 3 Air Flow Pos. 4 Spring Mount Code = 5F AND Seismic Mount Code = 5F3 Ref. Part Part Qty. No. Description Number Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Standard Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position 3 Seismic 3 Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position 4 Standard Motor H.P.= All Spring Isolator- Position 4 Seismic 3 Motor H.P.= All Spring Isolator- Position Standard Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Seismic 3 Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Standard Motor H.P.= All Spring Isolator- Position Seismic 3 Motor H.P.= All Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used when Code = 5F3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 35

36 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 30" and 40" Airfoil Fan Code = 30B, 40B, 30B, 40B, 30B3, 40B Rubber-In-Shear (RIS) Mount Code = 30B, 40B Ref. Part Part Qty. No. Description Number Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Washer Drawing is common to all four corners. Quantities listed are for ONE mount. Spring Mount Code = 30B, 40B AND Seismic Mount Code = 30B3, 40B3 Diagram Seismic strap used only when Code = **B Pos. 6 Pos. 3 Top View 64 Pos. 6 Air Flow Pos. 4 Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 36

37 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 30" and 40" Airfoil Fan Code = 30B, 30B3 Spring Mounting Code = 30B, and Seismic Mount Code = 30B3 Components Ref. Part 30" Qty. No. Description Fan Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Standard Motor H.P.= thru Motor H.P.= 5 thru Spring Isolator- Position 3 Seismic Motor H.P.= thru Motor H.P.= 5 thru Spring Isolator- Position 4 Standard Motor H.P.= All Spring Isolator- Position 4 Seismic Motor H.P.= All Spring Isolator- Position Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position Seismic Motor H.P.= thru Motor H.P.= Spring Isolator- Position Standard Motor H.P.= All Spring Isolator- Position Seismic Motor H.P.= All Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Quantity shown is for ONE mount. This part is used only when Code = 30B3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 37

38 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 30" and 40" Airfoil Fan Code = 40B, 40B3 Spring Mounting Code = 40B, and Seismic Mount Code = 40B3 Components Ref. Part 40" Qty. No. Description Fan Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 3 Seismic Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 4 Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 3 Seismic Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position Seismic Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position Standard Motor H.P.= All Spring Isolator- Position Seismic Motor H.P.= All Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Quantity shown is for ONE mount. This part is used only when Code = 40B3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 38

39 Section A- Outdoor/Return Air Section Return Air Fan Deck 5" Fans: Code = 5F, 5F, 5F Motor 7 9 9A Ref. Part Part Qty. No. Description Number 6 Wheel/Housing Assy Motor Shelf Filler Piece Shaft Tube Coupling N/S Tube Clamp Grease Fitting/Zerk A Coupling/Reducer Shim 3 5 Ball Bearing Key Key Motor Mount Bolt N/S= Not shown on diagram. Motors are listed after the fan deck details. Shims are used as needed. Any of the following may be used: (.058"); (.046"); (0."); (.03"). Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 39

40 Section A- Outdoor/Return Air Section Return Air Fan Deck 30" Fans: Code = 30B, 30B, 30B3 9A Motor 9 7 Ref. Part Part Qty. No. Description Number Bearing Funnel- Inlet Wheel- Fan Mount- Motor Shaft- Fan Tubing- Plastic Fitting- Grease A Fitting- Reducer Key Key 034 Motors are listed after the fan deck details. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 40

41 Section A- Outdoor/Return Air Section Return Air Fan Deck 40" Fans: Code = 40B, 40B, 40B Motor Ref. Part Part Qty. No. Description Number Inlet Funnel Bearing Support Lower Bearing Support Fan Wheel: SISW Fan Motor Mount Baffle Support Shaft Coupling Coupling Plastic tubing Grease Fitting Bearing Shaft Key Shaft Key Motors are listed after the fan deck details. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

42 Section A- Outdoor/Return Air Section Return Air Fan Motors Standard Motors: Code = **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff TEFC HiEff TEFC PrEff Motor Code = Voltage C= *EY C= *JY C= *HY C= *KY Mount C09= E*Y 08/60/ F*Y 08/60/ G*Y 08/60/ H*Y 08/60/ J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ C09= 9 E*Y 30/60/ F*Y 30/60/ G*Y 30/60/ H*Y 30/60/ J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ C09= 7 E*Y 460/60/ F*Y 460/60/ G*Y 460/60/ H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ C09= 37 E*Y 575/60/ F*Y 575/60/ G*Y 575/60/ H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ Note that the Return Fan Motor Mounts listed are used ONLY in Heat Recovery units built 04/0 & Earlier when Code = 4B* AND Code 0= *, *, 3*. See 4" Return Fan Detail (Section A). Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

43 Section A- Outdoor/Return Air Section Return Air Fan Motors Shaft Grounded Motors: Code = **S H.P. Motor HP Unit ODP PrEff TEFC PrEff C= **S Voltage C= *JS C= *KS C09= E*S 08/60/ N/A.5 F*S 08/60/ N/A G*S 08/60/ N/A 3 H*S 08/60/ J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ C09= 9 E*S 30/60/ F*S 30/60/ G*S 30/60/ H*S 30/60/ J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ C09= 7 E*S 460/60/ F*S 460/60/ G*S 460/60/ H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ C09= 37 E*S 575/60/ F*S 575/60/ G*S 575/60/ H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ N/A= Not Available. For Return Fan Motor Mounts used in Heat Recovery units (when Code = 4B* AND Code 0= *, *, 3*. See 4" Return Fan Detail (Section A). Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 43

44 Section A- Outdoor/Return Air Section Section Mounted Controls OAE, RAE, LT, S, REC Bottom Return Shown Code 9= BY, BE Economizer Damper 40 4 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n & Mount Minor field modifications are required for proper installation & operation when changing to the newer design. Bottom Return Shown Code 9= BY, BE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE BOTH original controls are obsolete & no longer available. For the OAE Control use & Mount For the RAE Control use & Mount Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay (OAER), are required for proper installation & operation. RAT- Return Air Temperature Sensor 7 Ref. Part Part Qty. No. Description Number 7 Sensor- RAT Return Air Opening 30 Return Air Opening SD- Return Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 30 Smoke Detector SD Back Return Code 9= HY Bottom Return Code 9= BY, BE LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Light Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 44

45 Section A- Outdoor/Return Air w/ Heat Recovery Section Notes Primary Codes that pertain: 9, 0,,, 3 (Mid 0 & Earlier); 4, 58 (Mid 0 & Later) Additional Codes that pertain: 06, 09, 4, 5, 6, 7, 48, 49; 3, 33 (Mid 0 & Later) Codes 9 and 0 determine the base section and Return Air Plenum. Code 0 determines the type of Outdoor Air/Heat Recovery control used. Code 0= *, * are 00% OA Air units, and if Code 0= 3* the unit has an Economizer. Codes,, 3 (Mid 0 & Earlier), AND/OR 58 (Mid 0 & Later) determine the Return Air Fan, Fan Motor, and drive selection. The fan section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 4 determines if the Heat/Energy Recovery Wheel has a Frost Protection Inverter. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air With Heat Recovery Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 09, the voltage, is part of the Return Fan Motor part number identification. Codes 4 & 5 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4=, 4, there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 determines the Inverter Vendor. For Inverter part numbers, refer to the Supply Air Section (Section F). If Code 6=, 3 a Smoke Detector (SD) is present in the Return Air Cabinet. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/ HGRH inverter brand specified, and/or the presence of Intelligent Equipment. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for part number and description. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Light (Code 49= E), Fan Belt Guards (Code 49= D) or both (Code 49= F). Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 45

46 Section A- Outdoor/Return Air w/ Heat Recovery Section 00% Outside Air Low Flow- Code 0= E Intake Hood (see detail to left) Outdoor Air Intake Hood Detail LH or 49 RH Exhaust Hood Detail 0 0 Ref. Part Part Qty. No. Description Number Fan Assembly Damper Assy- Low Leak Panel, Top- Hood Panel, LH Side- Outdoor Air Intake Hood Panel, RH Side- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Lower Louver- Outdoor Air Intake Hood Screen- Outdoor Air Intake Hood Gasket ft. 60 Wheel, Enthalpy- Heat Recovery 3 6 Motor- Enthalpy Wheel 3 6 Sheave- Fixed 3 0 Filter Rack Filter Rack Filter Rack Filter Rack Door, Indented- Exhaust LH Door, Indented- Exhaust RH Exhaust Hood N/S Filter 6 x 0 x N/S Filter 6 x 5 x N/S= Not Shown on Diagram. See Detail two pages after next. See Detail four pages after next. 3 See Detail in this section (A) titled "Heat Recovery-Enthalpy-Wheel Detail (Ref #60) Wheel Motor, Drive Components, Seals" Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 46

47 Section A- Outdoor/Return Air w/ Heat Recovery Section 00% Outside Air High Flow- Code 0= E Hood (see detail to left) Outdoor Air Intake Hood Detail LH or 49 RH Exhaust Hood Detail Ref. Part Part Qty. No. Description Number Fan Assembly Damper Assy- Low Leak Panel, Top- Hood Panel, LH Side- Outdoor Air Intake Hood Panel, RH Side- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Lower Louver- Outdoor Air Intake Hood Screen- Outdoor Air Intake Hood Gasket ft. 60 Wheel, Enthalpy- Heat Recovery 3 6 Motor- Enthalpy Wheel 3 6 Sheave- Fixed 3 0 Filter Rack Filter Rack Filter Rack Filter Rack Door, Indented- Exhaust LH Door, Indented- Exhaust RH Exhaust Hood N/S Filter 6 x 0 x N/S Filter 6 x 5 x N/S= Not Shown on Diagram. See Detail one page after next. See Detail four pages after next. 3 See Detail in this section (A) titled 'Heat Recovery-Enthalpy-Wheel Detail (Ref #60) Wheel Motor, Drive Components, Seals". Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 47

48 Section A- Outdoor/Return Air w/ Heat Recovery Section Economizer- Code 0= 3E Outdoor Air Intake Hood Detail Intake Hood Exhaust Hood Detail LH or 49 RH A Ref. Part Part Qty. No. Description Number Fan Assembly Damper Assy- Low Leak Outdoor Air (w/ ACT3) A Damper Assy- Low Leak Return Air (w/ ACT4) Panel, Top- Hood Panel, LH Side- Outdoor Air Intake Hood Panel, RH Side- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Lower Louver- Outdoor Air Intake Hood Screen- Outdoor Air Intake Hood Gasket ft. 60 Wheel, Enthalpy- Heat Recovery 3 6 Motor- Enthalpy Wheel 3 6 Sheave- Fixed 3 0 Filter Rack Filter Rack Filter Rack Filter Rack Damper Assy- Bypass Door, Indented- Exhaust LH Door, Indented- Exhaust RH Exhaust Hood N/S Filter 6 x 0 x N/S Filter 6 x 5 x N/S= Not Shown on Diagram. See Detail on next page. See Detail two pages after next. 3 See Detail in this section (A) titled "Heat Recovery-Enthalpy-Wheel Detail (Ref #60) Wheel Motor, Drive Components, Seals". 4 See Detail three pages after next. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 48

49 Section A- Outdoor/Return Air w/ Heat Recovery Section 4" Return Fan Detail: (04/ & Earlier) Code = 4B* AND Code 0= *, *, 3* Fan Assy, Motor and Motor Mounting 0C 0 0B 7 Thrust Restraint Detail A Ref. Part Part Qty. No. Description Number Motor- Return Fan Mount- Motor 7 Gasket Fan Wheel and Housing Assembly A Shaft Only B Bearing Only C Wheel Only Angle- Thrust Restraint Spring Mount, Floor- Thrust Restraint Red 75 lb N/S Spring Mount- Screw N/S= Not shown on diagram. See Return Fan Motor Tables for p/ns. Two screws are required per mount. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 49

50 Section A- Outdoor/Return Air w/ Heat Recovery Section 4" Return Fan Detail: (05/ & Later) Code = 4B* AND Code 0= *, *, 3* Ref. Part Part Qty. No. Description Number Motor- Return Fan 6 Mount- Motor Inlet Funnel Bearing- Ball,.687" Bearing- Ball,.687" Shaft,.687" Key- Shaft Wheel, 4" AF See Return Fan Motor Tables for p/ns. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 50

51 Section A- Outdoor/Return Air w/ Heat Recovery Section 4" Return Fan Detail: (04/0 & Earlier) Fan Mounts 35C 35D 35B 35A Fan Mounting Locations Top View A 35B 35C 35D Rubber- In- Shear (RIS) Mount Code = 4B Ref. Part Part Qty. No. Description Number 35A Vibration Mount Black B Vibration Mount Black C Vibration Mount thru HP Green thru 0 HP Black D Vibration Mount Black Nut- Hex Nut- Hex Screw Screw Nut- Hex Washer Washer Support- Green Vibration Mount /mt Support- Black Vibration Mount /mt Spring Mount Code = 4B OR Spring w/ Seismic Snubber Code = 4B A 35B 35C 35D 87 Ref. Part Part Qty. No. Description Number 35A Vibration Mount Red B Vibration Mount Red C Vibration Mount HP Black HP Red HP Green D Vibration Mount.5-5 HP Red HP Green Mount- Seismic Channel Nut- Hex Nut- Hex Spring (C= 4*) Nut- Hex Seismic (C= 4*3) Bolt Screw- Cap Washer Seismic snubber parts. Used only when Code = 4B3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

52 Section A- Outdoor/Return Air w/ Heat Recovery Section 4" Return Fan Detail: (05/0 & Later) Fan Mounts Fan Mounting Locations Top View Rubber-In-Shear (Code = 4B) Ref. Part Part Qty. No. Description Number Mount- RIS Mount- Channel Nut Screw Screw, Cap Nut Washer Screw, Cap Seismic strap used only when Code = 4B Spring (Code = 4B) OR Spring w/ Seismic Snubber (Code = 4B3) Ref. Part Part Qty. No. Description Number Spring-.5-0 HP Yellow , 35 Spring- 5-0 HP Green , 37 Spring- 5-0 HP Yellow Mount- Std. (Code = 4B) Mount- Seismic (Code = 4B3) Nut Screw Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

53 Section A- Outdoor/Return Air w/ Heat Recovery Section Low Leak Damper Detail, Part No (Ref. # OR A) Damper, Actuator (ACT3 - OA Damper and ACT 4 - RA Damper) ACT3 OR ACT4 Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator Complete Assy- Less Actuator Seal- End Stop- Damper End Plug Blade- Damper Actuator ACT3, 4 4V End Plug End Plug Bushing- Linkage Bushing- Damper Blade Shaft- Drive Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 53

54 Section A- Outdoor/Return Air w/ Heat Recovery Section Low Leak Bypass Damper Detail, Part No (Ref. #30) Damper, Actuator (ACT) Economizer Units (Code = 3E) ACT Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator Complete Assy- Less Actuator Seal- End Stop- Damper End Plug End Plug End Plug Blade- Damper Actuator ACT 4V Coupling- Shaft End Plug End Plug Bushing- Linkage Bushing- Damper Blade Shaft- Drive Lock Collar Gasket- Vinyl 7" L Gasket- Vinyl 7" L Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 54

55 Section A- Outdoor/Return Air w/ Heat Recovery Section Heat Recovery Enthalpy Wheel Detail (Ref. #60) Wheel, Motor, Drive Components, Seals Outdoor Air Out (Supply) Exhaust Air In (Return) Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 08/30/ Wheel Assy- Complete Wheel Segmented Motor 08/30/ Motor Sheave Bearing Shaft " x 7.7" Belt N/S Inner/Outer Seal N/S= Not Shown on diagram. Includes Motor, Shaft, Belt etc. If a replacement Wheel is required, it is suggested that this part number be used. This segmented Wheel ships disassembled which allows for easier shipping and installation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 55

56 Section A- Outdoor/Return Air w/ Heat Recovery Section VFD60 Frost Protection Inverter (Code 4= F) 00% OA Low Flow (Code 0= E) 00% OA Hi Flow (Code 0= E) Economizer (Code 0= 3E) Rear Filter Rack Upright 3 Rear Support Cross Member 3 Mid- Section Upright Rear Filter Rack RA Damper Assy Base Rail Mid- Section Junction Box Base Rail 3 Mid 0 & Earlier Voltage Ref. Sch. Part Part No. Sym. Description Number 3 VFD60 Inverter VFD60 Inverter VFD60 Inverter In Mid 0 the Unit Model Nomenclature was changed to code the different Inverter brands offered. Before this date ATV OR ATV drives (see note below) were standard. In 00 the original ATV Inverters were replaced with ATV Inverters as listed above. These Inverters are drop in replacements with the exception of the Remote Keypad and Communication Cards. If a Communication card OR Remote Keypad is required, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Note that since the original ATV drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV part fails, the entire drive must be replaced. 08V 30V Mid 0 & Later Voltage Ref. Sch. Part Part No. Sym. Description Number 3 Code 3= **A** 3 VFD60 Inverter Inverter Inverter Code 3= **B** 3 VFD60 Inverter Inverter Inverter Code 3= **Q** 3 VFD60 Inverter Inverter Inverter For the fusing for VFD60, refer to the "Energy Recovery Wheel Contactors, MMPs, & Fusing 04/3 & Later" page in Section N. 4 The replacement VFD Keypad is p/n V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 56

57 Section A- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls OAE, RAE, RAT, EAT, LAT Bottom Return Shown Code 9= BY, BE Economizer Damper 40 4 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n & Mount Minor field modifications are required for proper installation & operation when changing to the newer design. Bottom Return Shown Code 9= BY, BE Economizer Damper 4 48 RA Opening Deck Panel 00 4 OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE BOTH original controls are obsolete & no longer available. For the OAE Control use & Mount For the RAE Control use & Mount Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay (OAER), are required for proper installation & operation. RAT- Outdoor Air Temperature Sensor Ref. Part Part Qty. No. Description Number 84 Support- RAT Sensor- RAT EAT- Entering Air Temperature Sensor Return Fan Ref. Part Part Qty. No. Description Number 4 Support- EAT Sensor- EAT LAT- Leaving Air Temperature Sensor Ref. Part Part Qty. No. Description Number 58 Support- LAT Sensor- LAT Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 57

58 Section A- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls SD, HUM, LT, S, REC Heat Wheel 30 SD- Return Air Smoke Detector (Code 6=, 3) RA Opening 7 Ref. Part Part Qty. No. Description Number 7 Support- SD Smoke Detector- SD Return Air Opening RAT Deck Panel HUM- Humidistat (units with frost protection) Code 4= F Ref. Part Part Qty. No. Description Number 596 Support- HUM /6 & Earlier 0780 /7 & Later Humidistat- HUM /6 & Earlier /7 & Later This is the duct mounted Humidistat. If a unit has a wall mounted Humidistat use p/n LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Light Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 58

59 Section B- DrawThru Filter/Blank Section Notes Primary Codes that pertain: 5, 33 (Mid 0 & Later), 50 (Mid 0 & Later) Additional Codes that pertain: 06, 9, 0 Code 5 determines the section's characteristics. If the first digit of Code 5= A, D, E the Filters are in an angular rack, and if the first digit = F, G, H the Filters are in a flat rack. If the second digit = B there are 30% eff. throwaway filters and if C there are 30% eff. throwaway filters with Antimicrobial Intersept. If the second digit = D there are 65% eff. filters, if E there are 95% eff. filters, and if G there are 95% eff. filters with Antimicrobial Intersept. If the second digit = Y there is no filter media specified. If Code 5 = BY, CY there is a Blank/Empty section. Code 5= D*, E*, G*, H*, T*, V* OR Code 50 (Mid 0 & Later)= L, H indicates the presence of an Air Blender. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter gauge. Even though the gauge may be located in several different places in the unit, the p/n is listed in this section for convenience. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank Access Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Codes 9 and 0 determine the Return Air section which has an effect on the final assembly panels. Section B- DrawThru Filter/Blank Section Air Blender (Code 5= DB, DC, GD, GE, HD, HE, EB, EC OR Code 50 [Mid 0 & Later] L, H) 34 Ref. Part Code 5 OR Part Qty. No. Description Code 50 (Mid 0 & Later) Number 34 Air Blender Low CFM GD, GE, DB, DC, L High CFM HD, HE, EB, EC, H Section B- DrawThru Filter/Blank Section Section Mounted Controls PC5- Clogged Filter Control Ref. Part Part Qty. No. Description Number 65 Pressure Ctl- PC Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 59

60 Section B- DrawThru Filter Section Filter Section Diagrams and Components Typical Angular Filter Section Shown Code 5= A* Filter Section Parts Ref. Part Code Part Qty. No. Description 5= Number Angular Filter Section (Code 5= A*) N/S Filter 30% Pleated, 6 x 5 x " MERV 8 *B % Pleated, 6 x 5 x " w/ Intersept MERV 8 *C % Pleated, 6 x 5 x " MERV 3 *H N/S Filter 30% Pleated, 6 x 0 x MERV 8 *B % Disposable, 6 x 0 x " w/ Intersept MERV 8 *C % Pleated, 6 x 0 x MERV 3 *H N/S Media Filler Piece ALL Flat Filter Section (Code 5= F*) N/S Filter 65% Cartridge, 4 x 4 x " MERV *D % Cartridge, 4 x 4 x " MERV 4 *E % Cartridge, 4 x 4 x " w/ Intersept MERV 4 *G N/S Filter 65% Cartridge, x 4 x " MERV *D % Cartridge, x 4 x " MERV 4 *E % Cartridge, x 4 x " w/ Intersept MERV 4 *G N/S Pre Filter, 30% N/S Pre Filter, 30% N/S Gasket- /4" x /" N/S Gasket- Dbl Magnehelic/Differential Pressure Gauge Code 33= A****, B****, C**** (Mid 0 & Later) Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0-3 WC Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 60

61 Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes Primary Codes that pertain: 6, 4, 5 Additional Codes that pertain: 06 Code 6 determines if a section is installed and if so, the size of the section. If Code 6= S the section is 40" (this code is also necessary if the inverters are installed in this section), and if Code 6= T the section is 5". If Code 6= Y, there is no section. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4=,, 4 AND Code 6= S (Mid 03 & Earlier), there is a separate Inverter Section. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4= Y, there are no inverters. If Code 5= F, the unit is set up for a field supplied inverter. If Code 5= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the inverter(s) are listed in the Supply Air Section (Section F). Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Blank Access/Inverter Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

62 Section D- DrawThru Cooling Section Notes Primary Codes that pertain: 7, 8 Additional Codes that pertain: 06 NOTE: Section D applies only to unit sizes D. The DrawThru Evaporator Cooling Coil and associated components for unit sizes 05-03D are located in Section F (Supply Air Section). Code 7 determines if there is a Section D. If Code 7= YYYY, there is no section. If the first three digits of Code 7= CYY this is a cooling unit with a " section between the Filter and Supply Fan Sections. If the first three digits of Code 7= DYY then the section contains only a Drain Pan. If the first three digits of Code 7= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 7= S, the Drain Pan is stainless steel. P in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 7= T, then the unit is equipped with a wider than standard painted galvanized steel Drain Pan. If the fourth digit of Code 7= L, T then the first three digits of Code 7 must equal DYY. Code 8 determines Cooling Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

63 Section D- DrawThru Cooling Section Evaporator Coil Drain Pans and Gaskets Code 7= CYYY, CYYP, CYYS- " Section- Unit Sizes D Unit Base 4 Ref. Part Code 7= Part Qty. No. Description Number 3 Coil- refer to the following page 3 Drain Pan- Auxiliary 4/ & Earlier CYYY, CYYP, CYYS / & Later CYYP, CYYS Drain Pan- Main Galvanized CYYY Stainless Steel CYYS Gasket ft. Drain Pans Code 7= DYYY, DYYS- 40" Section- Unit Sizes D Diagram and Components 03 Unit Base Ref. Part Drain Pan Material Code 7= Qty. No. Description DYYY- Galvanized DYYS- Stainless 03 Drain Pan For Drain Pans and components when Code 7= GYY* and/or Code 7 Digit 4= L or T, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 63

64 Section D- DrawThru Cooling Section Evaporator Coils Unit Sizes D Typical Coil Description 4Z 08 3 D Fin Stock C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) Rows 3= 3 Row Coil 4= 4 Row Coil 5= 5 Row Coil 6= 6 Row Coil Fins-per-inch 08= 8 FPI 0= 0 FPI = FPI 4= 4 FPI Coil Model Evaporator Coils are serial number specific. Please contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 64

65 Section E- DrawThru Blank Access Section Notes Primary Codes that pertain: 30 Additional Codes that pertain: 06 If Code 30= BBBBBB, CCCCCC there is a blank 40" section. If Code 30= AAAAAA there is a blank " section. If Code 30= YYYYYY, there is no section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Blank Access Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Cabinet Door Gasketing and Hardware Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Section Mounted Controls LT7, REC7, S7- Section Mounted Light LT7- DT/Blank Section Light/S7- DT/Blank Section Light Switch/REC7- DT/Blank Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 65

66 Section F- Supply Air Section Notes Primary Codes that pertain: 3, 3, 33 (Mid 0 & Earlier), 59 (Mid 0 & Later), 4, 5, 49, (all unit sizes); 7, 8 (05-03D only) Additional Codes that pertain: 04, 06, 6, 7, 3 (Mid 0 & Later), 33 (Mid 0 & Later), 34 NOTE: The DrawThru Evaporator Cooling Section for unit sizes 05-03D is located in Section F. Components for the DrawThru Evaporator Section for unit sizes D are listed in Section D. Code 3 determines the Supply Fan size and type, Code 3 determines the Supply Fan Motor horsepower and type, and Code 33 (Mid 0 & Earlier) OR 59 (Mid 0 & Later) determine the drive selection. Supply Air Fan Section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Codes 4 and 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4=,, 4 AND/OR Code 6= S, there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the Inverter Vendor. If Code 5= F, the unit is set up for a field supplied inverter. If Code 5= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied. Code 49 determines if the Supply Air Fan Section has a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), or both (Code 49= C, F). Codes 7 and 8 determine the DrawThru Evaporator Section, and pertain to the coil and Drain Pan installed in section F for unit sizes 06-03D. If the first three digits of Code 7= CYY this is a cooling unit with the coil located in the Supply Fan Section. If the first three digits of Code 7= DYY then the section contains only a Drain Pan. If the first three digits of Code 7= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 7= S, the Drain Pan is stainless steel; P, Y in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 7= T, then the unit is equipped with a wider than standard painted galvanized steel Drain Pan. If the fourth digit of Code 7= L, T then the first three digits of Code 7 must equal DYY. Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, as well as the section installed controls. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 6 determines if a Smoke Detector is located in the Supply Air Cabinet. If Code 6=, 3, a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 5V Service Outlet, and/or Intelligent Equipment. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls, Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 3= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 66

67 Section F- Supply Air Section DrawThru Evaporator Coil Drain Pans Unit Sizes 05-03D Code 7= CYYY, CYYP, CYYS- 40" Section 3 Sizes 05, 08, Sizes 05, 030, Unit Base Unit Base 4 Ref. Part Code 7= Part Qty. No. Description Number 3 Coil- refer to the following page 3 Drain Pan- Auxiliary 4/ & Earlier CYYY, CYYP, CYYS / & Later CYYP, CYYS Drain Pan- Main Galvanized CYYY Stainless Steel CYYS Gasket ft. Drain Pans Unit Sizes 05-03D Code 7= DYYY, DYYS- 40" Section 03 Unit Base Ref. Part Drain Pan Material Code 7= Qty. No. Description DYYY- Galvanized DYYS- Stainless 03 Drain Pan For Drain Pans and components when Code 7= GYY* AND/OR Code 7 Digit 4= L, T, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 67

68 Section F- Supply Air Section Evaporator Coils Unit Sizes 05-03D Typical Coil Description 4Z 08 3 D Fin Stock C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) Rows 3= 3 Row Coil 4= 4 Row Coil 5= 5 Row Coil 6= 6 Row Coil Fins-per-inch 08= 8 FPI 0= 0 FPI = FPI 4= 4 FPI Coil Model Evaporator Coils are serial number specific. Please contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 68

69 Section F- Supply Air Section Fan Assembly 5" X 6" AND 5" X 5" Forward Curved Fans Code 3= 06F*, 5F* Unit Sizes 05-03D 5 3 Motor Ref. Part Fan Size: Code 3= Qty. No. Description 06F* 5F* Wheel Assembly Motor Mount Bolt Blower Frame Shaft Filler Piece Tubing Tubing Motor Base Tube Clamp Shim Shaft Key Shaft Key Coupling Coupling- Reducer Bearing- Pillow Block N/S Belt Guard Assy N/S= Not Shown on diagram. Any of the following shims may be used: (.0); (.03); (.046); (.046); (.058). Any of the following shims may be used: (.058); (.046); (.046); (.03); (.0). 3 Code 49= A, C, D, F. 4 Motors are listed after the fan mounting section. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 69

70 Section F- Supply Air Section Fan Assembly 0" Airfoil Fans Code 3= 0A, 0A, 0A3 Unit Sizes 05-03D 3 5 Motor Ref. Part Part Qty. No. Description Number Blower Housing Wheel: DWAF Motor Mount Shaft Motor Shelf Shaft Key Shaft Key Bearing N/S Grille- Belt Guard N/S= Not Shown on diagram. Motors are listed after the fan mounting section. Code 49= A, C, D, F. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 70

71 Section F- Supply Air Section Fan Assembly 4" Forward Curved LP Fans Code 3= 4F, 4F, 4F3 Unit Sizes D 0 0 Motor Ref. Part Part Qty. No. Description Number 0 Housing Base Mount- Bearing Wheel Screw- Adjusting Shaft Cut Off Plate Mount- Motor Angle- Mount Angle- Mount Shim- Lower Shaft Key Shaft Key Bearing N/S Belt Guard Assy N/S= Not Shown on diagram. Motors are listed after the fan mounting section. Code 49= A, C, D, F. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

72 Section F- Supply Air Section Fan Assembly 4" Airfoil Fans Code 3= 4A, 4A, 4A3 Unit Sizes D Wheels- View looking TOWARDS Discharge Opening Motor Ref. Part Part Qty. No. Description Number Blower Housing Wheel: SISW C.W Wheel: SISW C.C.W Shaft Mount- Motor Angle- Mount Angle- Motor Mount Key Key Bearing N/S Belt Guard Assy N/S= Not Shown on diagram. Motors are listed after the fan mounting section. Code 49= A, C, D, F. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

73 Section F- Supply Air Section Supply Air Fan Mounting- 5" x 6" Forward Curved Fan Code 3= 06F, 06F, 06F3 9 Rubber-In-Shear (RIS) Mount Code 3= 06F Ref. Part Part Qty. No. Description Number Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 3 Top View 34 Pos. 3 Seismic strap used only when Code 3= 06F Pos. 3 Air Flow Pos. 4 Spring Mounting Code 3= 06F OR Seismic Mount Code 3= 06F3 Ref. Part Part Qty. No. Description Number Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 7.5 thru Motor H.P.= Spring Isolator- Position 4 Motor H.P.= thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 7.5 thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 0 thru Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 06F3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 73

74 Section F- Supply Air Section Supply Air Fan Mounting- 5" X 5" Forward Curved Fan Code 3= 5F, 5F, 5F3 9 Rubber-In-Shear (RIS) Mount Code 3= 5F Ref. Part Part Qty. No. Description Number Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 3 Top View 34 Pos. 3 Seismic strap used only when Code 3= 5F Pos. 3 Air Flow Pos. 4 Spring Mounting Code 3= 5F OR Seismic Mount Code 3= 5F3 Ref. Part Part Qty. No. Description Number Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 7.5 thru Motor H.P.= Spring Isolator- Position 4 Motor H.P.= All Spring Isolator- Position Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= 5 thru Spring Isolator- Position Motor H.P.= thru Motor H.P.= 0 thru Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 5F3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 74

75 Section F- Supply Air Section Supply Air Fan Mounting- 0" Airfoil Fan Code 3= 0A, 0A, 0A3 9 3 Rubber-In-Shear (RIS) Mount Code 3= 0A Ref. Part Part Qty. No. Description Number Support Mount Spring Isolator- Position 3 Motor H.P.= All Spring Isolator- Position 4 Motor H.P.= All Spring Isolator- Position Motor H.P.= thru Motor H.P.= 0 thru Spring Isolator- Position Motor H.P.= All Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 3 Top View 34 Pos. 3 Seismic strap used only when Code 3= 0A Pos. 3 Air Flow Pos. 4 Spring Mounting Code 3= 0A OR Seismic Mount Code 3= 0A3 Ref. Part Part Qty. No. Description Number Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 3 thru Motor H.P.= Spring Isolator- Position 4 Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position Motor H.P.= thru Motor H.P.= 3 thru Motor H.P.= 7.5 thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= 5 thru Nut Spring Mount- Standard Spring Mount- Seismic Nut Screw Spring Mount- Standard Spring Mount- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 0A3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 75

76 Section F- Supply Air Section Supply Air Fan Mounting- 4" Airfoil Fan Code 3= 4A, 4A, 4A3 9 Rubber-In-Shear (RIS) Mount Code 3= 4A Ref. Part Part Qty. No. Description Number Support Mount Isolator- RP- 3 Red Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount. Spring Mounting Code 3= 4A OR Seismic Mount Code 3= 4A Pos. 3 Top View 34 Pos. 3 Seismic strap used only when Code 3= 4A Pos. 3 Air Flow Pos. 4 Ref. Part Part Qty. No. Description Number Mount- Spring Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 5 thru Spring Isolator- Position 4 Motor H.P.= All Spring Isolator- Position Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 0 thru Nut Spring Mount- Standard Spring Mount- Seismic Nut Screw Spring Mount- Standard Spring Mount- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 4A3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 76

77 Section F- Supply Air Section Supply Air Fan Mounting- 4" Forward Curved Fan Code 3= 4F, 4F, 4F3 9 Rubber-In-Shear (RIS) Code 3= 4F Ref. Part Part Qty. No. Description Number Support Mount Isolator RP- 3 Red Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 3 Top View 34 Pos. 3 Seismic strap used only when Code 3= 4F Pos. 3 Air Flow Pos. 4 Spring Mounting Code 3= 4F OR Seismic Mount Code 3= 4F3 Ref. Part Part Qty. No. Description Number Mount- Spring Spring Mount- Standard Seismic Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 5 thru Spring Isolator- Position 4 Motor H.P.= All Spring Isolator- Position Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 0 thru Nut Spring Mount- Standard Seismic Mount- Seismic Nut Screw Spring Mount- Standard Seismic Mount- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 4F3. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 77

78 Section F- Supply Air Section Supply Air Fan Motors Standard Motors: Code 3= **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff TEFC HiEff TEFC PrEff Code 3= Voltage C3= *EY C3= *JY C3= *HY C3= *KY C09= E*Y 08/60/ F*Y 08/60/ G*Y 08/60/ H*Y 08/60/ J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ P*Y 08/60/ C09= 9 E*Y 30/60/ F*Y 30/60/ G*Y 30/60/ H*Y 30/60/ J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ P*Y 30/60/ C09= 7 E*Y 460/60/ F*Y 460/60/ G*Y 460/60/ H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ C09= 37 E*Y 575/60/ F*Y 575/60/ G*Y 575/60/ H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 78

79 Section F- Supply Air Section Supply Air Fan Motors, Continued Shaft Grounded Motors: Code 3= **S H.P. Motor HP Unit ODP PrEff TEFC PrEff C3= **S Voltage C3= *JS C3= *KS C09= E*S 08/60/ N/A.5 F*S 08/60/ N/A G*S 08/60/ N/A 3 H*S 08/60/ J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ P*S 08/60/ C09= 9 E*S 30/60/ F*S 30/60/ G*S 30/60/ H*S 30/60/ J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ P*S 30/60/ C09= 7 E*S 460/60/ F*S 460/60/ G*S 460/60/ H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ C09= 37 E*S 575/60/ F*S 575/60/ G*S 575/60/ H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ N/A= Not Available. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 79

80 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP - 5 (Code OR Code 3= E*Y, F*Y, G*Y, H*Y, J*Y) 03/03 & Earlier- Diagrams Inverters may be located in a separate section (Code 4=,, 4 [Only inverters WITH bypass may be installed in a separate section.]), or the Supply Air Section (Code 4= 3, 5, 6, 7, 8, 9). The Inverter and bypass controls are the same regardless of the installation location, although sheet metal components differ. The diagrams shown below apply to either a Return or Supply Air Inverter (both may be installed if Code 4= 5). Even if Code 4= 8, 9 when only a Return Air Fan Inverter is called for the inverter and bypass controls are still installed in the Supply Air Section. 7 LR0 (Supply) LR0 (Return) 40 MMP30 (Supply) MMP40 (Return) M30B/M30I (Supply) M40B/M40I (Return) Supply Air OR Return Air Fan Inverter with Bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code 4= 5 Bypass Controls Detail Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) 7 MMP & Contactor Link Detail Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 80

81 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP - 5 (Code OR Code 3= E*Y, F*Y, G*Y, H*Y, J*Y) 03/03 & Earlier- Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30, 40 Motor Control LR0, 0 Line Reactor M30B, I Contactor M40B, I Aux. Contact Link Module Line Reactors used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8. These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

82 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP - 5 (Code OR Code 3= E**, F**, G**, H**, J**) 4/03 & Later- Diagrams Inverters may be located in a separate section (Code 4=,, 4 [Only inverters WITH bypass may be installed in a separate section.]), or the Supply Air Section (Code 4= 3, 5, 6, 7, 8, 9). The Inverter and bypass controls are the same regardless of the installation location, although sheet metal components differ. The diagrams shown below apply to either a Return or Supply Air Inverter (both may be installed if Code 4= 5). Even if Code 4= 8, 9 when only a Return Air Fan Inverter is called for the inverter and bypass controls are still installed in the Supply Air Section. MMP30 (Supply) 70 LR0 (Supply) 7 MMP40 (Return) 70 LR0 (Return) Supply Air OR Return Air Fan Inverter with Bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code 4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

83 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP - 5 (Code OR Code 3= E**, F**, G**, H**, J**) 4/03 & Later- Components Phase Barrier Front Mtd. Aux. Contact 70B 70A MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Link 70C 7 Link 70C 7A Spacer Contactor 7 Contactor MMP30/40 & M30/40 Link Detail - HP Motors- All Voltages 3, 5 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 3, 5 HP Motors- 08/30V Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 0 Inverter- see Inverter section 50 Gasket MMP30, 40 Motor Protector A Phase Barrier B Aux. Contact C Link LR0, 0 Line Reactor M30B, I Contactor M40B, I A Spacer V 30V 08V 30V 08V 30V 08V 30V 08V 30V Line Reactors used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8. These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 83

84 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code = K*Y, L*Y, M*Y, N*Y OR Code 3= K*Y, L*Y, M*Y, N*Y, P*Y) 03/03 & Earlier- Diagrams 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) MMP30 (Supply) MMP40 (Return) 7 LR0 (Supply) LR0 (Return) 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 5, 8) Two boxes installed if C4= 5 7 M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail MMP & Contactor Link Detail MMP p/n xx MMP & Contactor Link Detail MMP p/n , 48, 49 MMP & Contactor Link Detail MMP p/n Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 84

85 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code = K*Y, L*Y, M*Y, N*Y OR Code 3= K*Y, L*Y, M*Y, N*Y, P*Y) 03/03 & Earlier- Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 VFD0,0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30, 40 Motor Control LR0, 0 Line Reactor Line Reactors used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8. These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 85

86 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code = K*Y, L*Y, M*Y, N*Y OR Code 3= K*Y, L*Y, M*Y, N*Y, P*Y) 03/03 & Earlier- Components, Continued Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 7 M30B,I Contactor M40B,I Contact- Auxiliary Link Interlock- Trip Lug Kit (3 per kit) Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 86

87 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code = K**, L**, M**, N** OR Code 3= K**, L**, M**, N**, P**) 4/03 & Later- Diagrams 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) MMP30 (Supply) MMP40 (Return) 70 LR0 (Supply) 7 70 LR0 (Return) 7 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 5, 8) Two boxes installed if C4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Link 70C 7 Link 70C 7A Spacer Contactor 7 Contactor MMP30/40 & M30/40 Link Detail 7.5 HP Motors- Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/30V 5, 0 HP Motors- 0 HP Motors- 5 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 7.5 HP Motors- 08/30/ 0, 5 HP Motors- Phase Barrier 70A Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 87

88 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code = K**, L**, M**, N** OR Code 3= K**, L**, M**, N**, P**) 4/03 & Later- Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30,40 Motor Protector A Phase Barrier B Contact- Auxiliary C Link Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 88

89 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code = K**, L**, M**, N** OR Code 3= K**, L**, M**, N**, P**) 4/03 & Later- Components, Continued Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 7 LR0, 0 Line Reactor V 30V 08V 30V 08V 30V 08V 30V 08V 30V 7 M30B, I M40B, I Contactor 9A A A A A A A A A Spacer Line Reactors used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 89

90 Section F- Supply Air Section Inverters Code 5= A AND/OR Code 3 (Mid 0 & Later)= **A** Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number The replacement VFD Keypad Display is p/n Code 5= R Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number Note that the manufacturer has made changes to this inverter line. BEFORE ORDERING contact Daikin Applied to ensure compatibility and that no additional components are required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 90

91 Section F- Supply Air Section Inverters, Continued Code 5= G Motor Horsepower,.5, Part Number V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

92 Section F- Supply Air Section Inverters, Continued Code 5= S, Q AND/OR Code 3 (Mid 0 & Later)= **Q** 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number , , , , , , , Units built late 00 & earlier shipped with ATV VFDs. All ATV drives have been replaced with ATV drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV Remote Keypad is p/n The ATV Lonworks communication card is p/n The ATV Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The ATV Lonworks communication card is p/n All other ATV communication cards are integral to the VFD and are not available separately. Note that since the original ATV drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV part fails, the entire drive must be replaced. MD3 Remote Keypad p/n is MD6 Remote Keypad p/n is plus Mount p/n For units with an MD3 Inverter and Motor under 5 HP a Line Reactor will be installed regardless of whether one is specified in Code 7 (see nomenclature page). Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

93 Section F- Supply Air Section Inverters, Continued Code 5= B OR Code 3 (Mid 0 & Later)= **B** 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number The replacement VFD Keypad Display is p/n Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 93

94 Section F- Supply Air Section Section Mounted Controls PC7, EFT, HL, LT0, S0, REC0, UV Lights PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket 9 Pressure Control- PC7 0 Pneumatic Fitting In mid 0 the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 9043 for proper installation as old and new parts are NOT interchangeable. The Control only is p/n , the Pneumatic Fitting is p/n 9044, and the Support Bracket is p/n EFT- Entering Fan Temperature Sensor Ref. Part Part Qty. No. Description Number 36 Sensor- EFT Bracket- EFT A HL- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 67 T-stat- HL Hi Limit A Support- HL LT0- Supply Fan Light/S0- Supply Fan Light Switch/REC0- Supply Fan Light Receptacle Code 49= B, E Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC UV Lights Code 7= C thru C8 AND Y thru Y8 Ref. Part Part Qty. No. Description Number 98 Light Fixture- 8" Bulb Light Fixture- 4" Bulb Light Fixture- 36" Bulb Bulb/Lamp, UV- 8" Bulb/Lamp, UV- 4" Bulb/Lamp, UV- 36" Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 94

95 Section G- BlowThru Heat Section Notes Primary Codes that pertain: 04, 34 Additional Codes that pertain: 06, 07, 09,, 3 This section is divided into four subsections:. Blank Access;. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat. Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section's characteristics. If Code 04= Y, AND Code 34= YYYYYY there is no section. If Code 04= Y AND Code 34= BBBBBB, then there is a 40" Blank Access Section installed. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heating Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is UL approved (USA) or ETL approved (Canada). Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls. Code determines the Control type and will affect the Gas Heat Actuator. Code 3 is the Supply Fan size, and affects the heat section's Diffusers. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 95

96 Section G- BlowThru Heat Section Option : Blank/Empty Section Code 34= BBBBBB AND Code 04= Y Diffusers Units with 5" X 6" OR 5" X 5" Supply Fan Code 3= 06F*, 5F* Units with 0" OR 4" Supply Fan Code 3= 0**, 4** Ref. Part Part Qty. No. Description Number Diffuser Code 3= 06F*, 5F* Code 3= 0**, 4** Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 96

97 Section G- BlowThru Heat Section Option : Hot Water OR Steam Heating Coil Code 04= W, S AND Code 34= W****E, S****E Coils and Coil Compartment Components Diffuser Units with 5" Supply Fan Code 3= 06F*, 5F* Diffuser Units with 0" OR 4" Supply Fan Code 3= 0**, 4** FS Freezestat Ref. Part Part Qty. No. Description Number Coil 9/ & Earlier Steam Coil- 6 FPI/ Row (C34= S***) Steam Coil- FPI/ Row (C34= S***) Hot Water- 9 FPI/ Row (C34= W***) Hot Water- 9 FPI/ Row (C34= W***) Diffuser Code 3= 06F*, 5F* Code 3= 0**, 4** Fin Channel (- Row Coil Only) Bottom Baffle (C36= 5Z**** only) Row Coil (C34= W***, S***) Row Coil (C34= W***) Freezestat- FS Coils for units built 0/ & Later are serial number specific. Contact Daikin Applied with model and serial number information so that the correct coil can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 97

98 Section G- BlowThru Heat Section Option : Hot Water OR Steam Heating Coil Code 04= W, S AND Code 34= W****E, S****E Valves Steam Coil Units Code 34= S*E, S*E Hot Water Coil Units Code 34= W*3E, W*3E Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number 49 Valve, Way Steam Heat w/ Act..00 S**DE 5JA All S**EE 5JA All S**FE 5JA All S**GE 5JA All VM Actuator- 4V, HW Heat W***3E All All Valve, 3 Way HW w/ Actuator.00 W**D3E 5WH, 5WS All.5 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All N/S= Not shown on diagram. Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 98

99 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Diffusers, High Limit HL4, HL4 & HL 3-50 Diffusers: Units with 5" Supply Fan Code 3= 06F*, 5F* Heaters, Hi-Limit Switches Units with 0" OR 4" Supply Fan Code 3= 0**, 4** HL4 HL4 Control Box (see page after next) 34 Ref. Part Part Qty. No. Description Number Diffuser Code 3= 06F*, 5F* Code 3= 0**, 4** Hi Limit- HL4, HL Heaters- See charts on following page N/S Hi Limit Switches: HL3-50 (part of heater assys.) var. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 99

100 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heating Assemblies and Elements This chart defines the letters used in the charts below. Complete assemblies include heater elements, hardware and the control HiLimit switch (HL3-50). The Heater Assembly contains the elements less the HiLimit Control and its associated hardware. DUE TO MANY AVAILABLE SPECIAL HEATER OPTIONS, BE VERY CAREFUL SELECTING HEATER AND HEATER COMPONENTS TO ENSURE CORRECT HEATER SELECTION. Ref. Letter A B C D E F Complete Assy Heater Assy Element Only (6) (6) (6) () (6) (6) Ref. Letter G H I J K L Complete Assy Heater Assy Element Only (6) (6) (6) () (6) (6) Heater Cross Reference: 08/30/60/3 Units (Code 09=, 9) This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part # (Qty. = ). Heater KW- Code 34= Ref. E00** E040** E060** E080** E00** E0** E40** E60** E80** E00** E0** E40** No. Qty. 0kw 40kw 60kw 80kw 00kw 0kw 40kw 60kw 80kw 00kw 0kw 40kw 3 A B C D D D D D N/A N/A N/A N/A 3 A B C D D D D D N/A N/A N/A N/A 4 U U U U A B C D N/A N/A N/A N/A 4 N/A N/A N/A N/A A B C D N/A N/A N/A N/A 5 U U U U U U U U N/A N/A N/A N/A 5 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Heater Cross Reference: 380/50/3 & 460/60/3 Units (Code 09= 7, 8) This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part # (Qty. = ). Heater KW- Code 34= Ref. E00** E040** E060** E080** E00** E0** E40** E60** E80** E00** E0** E40** No. Qty. 0kw 40kw 60kw 80kw 00kw 0kw 40kw 60kw 80kw 00kw 0kw 40kw 3 E F G H G G H H G H H H 3 E F G H G G H H G H H H 4 U U U U F G G H G G H H 4 N/A N/A N/A N/A F G G H G G H H 5 U U U U U U U U G G G H 5 N/A N/A N/A N/A N/A N/A N/A N/A G G G H Heater Cross Reference: 575/60/3 Units (Code 09= 37) This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part # (Qty. = ). Heater KW- Code 34= Ref. E00** E040** E060** E080** E00** E0** E40** E60** E80** E00** E0** E40** No. Qty. 0kw 40kw 60kw 80kw 00kw 0kw 40kw 60kw 80kw 00kw 0kw 40kw 3 I J K L K K L L K L L L 3 I J K L K K L L K L L L 4 U U U U J K K L K K L L 4 N/A N/A N/A N/A J K K L K K L L 5 U U U U U U U U K K K L 5 N/A N/A N/A N/A N/A N/A N/A N/A K K K L Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 00

101 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box No Controls (Code = YM) Diagrams FB33 FB3 FB3 F33 F33 F33 F3 F3 F3 F3 F3 F3 M33 M3 M3 SR SR FB43 FB4 FB4 F43 F43 F43 F4 F4 F4 F4 F4 F4 SR3 SR Control Panel SR3 SR T5 T5 M43 M4 M4 R3 TB R3 TB PB3 Power Panel Detail Control Panel Detail Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

102 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box No Controls (Code = YM) Components Relays, Power Block, Terminal Block, T5 Transformer and Control Sequencer Heater KW= 0/ Sch. Part Part Sym. Description Number PB3 Power Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V TB Terminal Block R3 Relay- DPDT Socket- R T5 Transformer SR Ctl- Sequencer SR Ctl- Sequencer SR3 Ctl- Sequencer Part number is for one section. The number of sections used is determined by the options installed. Fuse Blocks Heater KW= 0/ Sch. Part Part Sym. Description Number FB3 Fuse Block FB3 Fuse Block FB33 Fuse Block FB4 Fuse Block FB4 Fuse Block FB43 Fuse Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

103 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E No Controls (Code = YM) Components, Continued Fuses Heater KW= 0/ Sch. Part Part Sym. Description Number F3 Fuse V 30V 08V 30V 08V 30V 08V 30V 08V 30V F3 Fuse F33 Fuse F4 Fuse F4 Fuse F43 Fuse Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 03

104 Contactors: (03/03 & Earlier) Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box No Controls (Code = YM) Components, Continued Heater KW= 0/ Sch. Part Part Sym. Description Number M3 Contactor Contactor M3 Contactor Contactor M33 Contactor M4 Contactor Contactor M4 Contactor Contactor M43 Contactor V 30V 08V 30V 08V 30V 08V 30V 08V 30V Contactors: (04/03 & Later) Heater KW= 0/ Sch. Part Part Sym. Description Number M3 Contactor Contactor M3 Contactor Contactor M33 Contactor M4 Contactor Contactor M4 Contactor Contactor M43 Contactor V 30V 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 04

105 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box MicroTech III (Code = *E, *F, *W) Diagram The above diagram shows a typical Electric Heat Control Box layout and is to be used for reference only. Specific unit configuration and components used differ depending upon options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 05

106 Fuses Sch. Part Sym. Description Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box MicroTech III Units (Code = *E, *F, *W) Components Heater KW= 0/ Part Number Fuse-F V 30V 08V 30V 08V 30V 08V 30V 08V 30V Fuse-F Fuse-F Fuse-F Fuse-F Fuse-F Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 06

107 Fuse & Terminal Blocks Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box MicroTech III Units (Code = *E, *F, *W) Components, Continued Heater KW= 0/ Sch. Part Part Sym. Description Number FB3 Fuse Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V FB3 Fuse Block FB33 Fuse Block FB4 Fuse Block FB4 Fuse Block FB43 Fuse Block PB3 Power Block TB Terminal Block Part number is for one section. The number of sections used is determined by the options installed. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 07

108 Contactors: (03/03 & Earlier) Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box MicroTech III (Code = *E, *F, *W) Components, Continued Heater KW= 0/ Sch. Part Part Sym. Description Number M3 Contactor Contactor M3 Contactor Contactor M33 Contactor M4 Contactor Contactor M4 Contactor Contactor M43 Contactor V 30V 08V 30V 08V 30V 08V 30V 08V 30V Contactors: (04/03 & Later) Heater KW= 0/ Sch. Part Part Sym. Description Number M3 Contactor Contactor M3 Contactor Contactor M33 Contactor M4 Contactor Contactor M4 Contactor Contactor M43 Contactor V 30V 08V 30V 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 08

109 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers & Vestibules 00, 50 MBH Furnaces Code 34= 00**, 05** Heat Exchanger Burner 38 Burner Control Box Gas Train 3 Ref. Part 00/50 Qty. No. Description MBH Heat Exchanger Vestibule Vestibule Capillary Plate N/S Turbulator Assy N/S= Not shown on diagram. Parts detail follows this section. Parts detail follows Burner section. 3 Parts detail follows Burner Control Box section. 4 Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulator Assemblies must be ordered separately. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 09

110 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers & Vestibules 30, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces Code 34= 03**, 040**, 050**, 064**, 065**, 079**, 080**, 00** Heat Exchanger 300 Burner Burner Control Box Gas Train 3 Ref. Part 30/ / / /000 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger Vestibule Vestibule N/S Turbulator N/S= Not shown on diagram. Parts detail follows this section. Parts detail follows Burner section. 3 Parts detail follows Burner Control Box section. 4 Quantity varies depending upon the size of the Heat Exchanger. For 30/400 MBH order 6 pc.; for 500/640 MBH order 9 pc.; for 650/790 MBH order pc.; for 800/000 MBH order 5 pc. Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulators must be ordered separately. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

111 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Box, Pilot Valve & Pressure Regulator Code 34= ****E*, ****R*, ****S* Diagram Burner Control Box , 50, 30 MBH Burners MBH Burners Pilot Valve/ Pressure Regulator Assy Detail 60 Burner Control Box Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

112 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34= ****E*, ****R*, ****S* Components Ref. Part Burner Approval Code Qty. No. Description C07= E* C07= CC, CD ETL- USA Canada 0 Burner Housing Fan Wheel Housing Wheel-.5" bore Motor-.5 HP, 5/60/ Gun Assembly 00 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace Pilot Mixer Pilot Assembly Damper Assembly Blast Tube Gasket Right Side Damper MBH Furnace MBH Furnace MBH Furnace Left Side Damper MBH Furnace MBH Furnace Slide Damper 00 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

113 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34= ****E*, ****R*, ****S* Components, Continued Ref. Part Burner Approval Code Qty. No. Description C07= E* C07= CC, CD ETL- USA Canada 7 Blower Gasket Burner Cover Ignition Cable Assembly 0 Glass Cover Glass Cover Support Orifice 00 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Clip Flange Bearing Air Switch Tube Pilot Burner Tube MBH Furnace MBH Furnace Compression Fitting Pilot Tube Manual Cock Valve Not Used Pressure Regulator Valve Not Used º Compression Elbow Not Used Motor Conduit Box Torsion Spring Not Used Burner Box Baffle MBH Furnace MBH Furnace Valve- Pressure Regulator Valve- Manual: MBH Valve- Solenoid: MBH N/S Flame Rod N/S Ignition Electrode Assy N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

114 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Diagram MBH MBH Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

115 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components Burner Approval Code Ref. Part C07= E* C07= CC, CD Qty. No. Description ETL- USA Canada 0 Burner Housing Fan Wheel Housing MBH Furnace MBH Furnace Wheel MBH Furnace MBH Furnace Motor MBH Furnace MBH Furnace Gun Assembly 00 MBH Furnace N/A 50 MBH Furnace N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

116 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Ref. Part C07= E* C07= CC, CD Qty. No. Description ETL/MEA- USA Canada 0 Orifice Assembly 00 MBH Furnace N/A 50 MBH Furnace N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace , 800 MBH Furnace MBH Furnace Gasket- Blast Tube Air Box Assy Plate- Actuator Scale Gasket- Blower Panel- Burner Box Cover Ignition Wire Assy 0 Glass Cover- Burner Support- Glass Cover Grommet- Flat Box- Conduit Motor- Actuator 0V Motor- Actuator 4V Control Arm Control Rod Crank Arm Extension- Crank Arm Bushing- Control Rod Air Linkage Air Plate- Adjustable 00 MBH Furnace N/A 50 MBH Furnace N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Normally units without controls (Code = YM, YC) use a 0V Actuator and units with controls (Code = *D, *S, *E,*F, *W) use a 4V Actuator. Confirm voltage required BEFORE ordering. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

117 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Ref. Part C07= E* C07= CC, CD Qty. No. Description ETL/MEA- USA Canada 3 Air Plate- Profile 00, 50 MBH Furnaces N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Plate- Slide Damper 00, 50, 30, 400 MBH Furnaces MBH Furnace , 650 MBH Furnaces , 800, 000 MBH Furnaces Box- Air MBH Furnaces MBH Furnaces Gasket- Air Box Grommet Bearing- Sleeve Grommet MBH only N/A= Not available. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

118 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls Code 34= ****E*, ****R*, ****S* No Controls (Code = YC, YM) Diagram FSG Detail Gas Control Box Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

119 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls Code 34= ****E*, ****R*, ****S* No Controls (Code = YC, YM) Components Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 00/ GV Pressure Reg. Assy Valve Only Manual Cock Valve Not Used Solenoid Valve Not Used Not Used Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada S3 Toggle Switch- 4PST IT Ignition Transformer Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper, Row Terminal Block Jumper, 3P Fitting Bushing R0 Relay (Before /0) N/S R0A Relay (After /0) N/S Relay Socket R3 Pilot Relay (Before /0) N/S R3A Pilot Relay (After /0, ETL only) N/S Mounting Adapter N/S R3B Pilot Relay (After /0) N/S Relay Socket N/S= Not Shown on diagram. Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

120 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls (Code 34= ****E*, ****R*, ****S*) MicroTech III Controls (Code = *E, *F, *W) R3B IT 5 4 R3A Gas Control Box FSG Detail R0A AS TB FLC Panel Detail S3 GV Detail FSG 5 Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 00/ GV Pressure Reg. Assy Valve Only Manual Cock Valve Not Used Solenoid Valve Not Used Not Used Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada S3 Toggle Switch- 4PST IT Ignition Transformer AS Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Block Terminal Block End Stop Terminal Block End Plate Jumper Terminal R0A Relay- High Amp DPDT/0V R3A Relay- High Amp DPDT/0V R3B Relay- Low Amp DPDT/0V Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

121 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls Code 34= ****H*, ****T*, ****U* No Controls (Code = YC, YM) Diagram TB 34 TD0 R R R Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

122 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls Code 34= ****H*, ****T*, ****U* No Controls (Code = YC, YM) Components Ref. Sch. Part Part Qty. No. Sym. Description Number Support Support Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper, Row Terminal Block Jumper, 3P Fitting Bushing Bushing N/S R0A Relay 0V N/S Mounting Adapter N/S R0B Relay 0V Relay Socket R3 Relay- 0V/DPDT (Before 03/0) N/S R3A Relay 0V N/S Mounting Adapter N/S R3B Relay- 0VSPST (After 03/0) Relay Socket R Relay- 0V/DPDT (Before 03/0) R Relay- 0V/DPDT (After 03/0) Relay Socket R Relay- 0VSPST (Before 03/0) R Relay- 0VSPST (After 03/0) N/S Mounting Adapter TD0 Relay- Time Delay 0.0 Sec N/S= Not Shown on diagram. Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

123 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls Code 34= ****H*, ****T*, ****U* MicroTech III Controls (Code = *E, *F, *W) R IT R0B 6 R0A 6 AS 3 LS LS 34 TB 3 FLC 4 33 LS, 5 9 S3 6 7 FSG FSG Detail Ref. Sch. Part Part Qty. No. Sym. Description Number 4 Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper R0A Relay-High Amp DPDT/0V R0B Relay- Low Amp DPDT/0V R Relay- Low Amp DPDT/0V Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

124 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34= ****E*, ****R*, ****S* Gas Train Inlet Units without Pressure Regulator Valve: Code 34= ****E* 6 Ref. Part Part Qty. No. Description Number 6 Gas Valve 00, 50, 30 MBH , 500 MBH MBH Units with Pressure Regulator Valve: Code 34= ****R*, ****S* , 500, 640 MBH Furnaces 8 650, 790, 800, 000 MBH Furnaces 8 00, 50, 30 MBH Furnaces Ref. Part Pressure Regulator Qty. No. Description Code 34= ****R* Code 34= ****S* 05 Shutoff Valve MBH Pressure Regulator 00, 50, 30 MBH MBH MBH , 650 MBH , 800 MBH MBH Gas Valve 00, 50, 30 MBH , 500 MBH MBH Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

125 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Gas Train Inlet Units without Pressure Regulator Valve: Code 34= ****H* 6 Ref. Part Part Qty. No. Description Number 6 Gas Valve 00, 50, 30 MBH , 500 MBH MBH Units with Pressure Regulator Valve: Code 34= ****T*, ****U* 3 Back Wall of Vestibule ETL USA Units Code 07= E* (also Canada MBH ) Canada Units Code 07= C* (except MBH) Canada Units Code 07= C* Pilot Valve Detail Ref. Part Pressure Regulator Qty. No. Description Code 34= ****T* Code 34= ****U* 6 Shutoff Valve 00, 50, 30 MBH MBH MBH Pressure Regulator 00, 50, 30 MBH MBH MBH , 650 MBH , 800 MBH MBH Valve- Combination Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

126 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34=****E*, ****R*, ****S* Gas Train Controls GV, GV MBH Furnaces GV Gas Controls: 00, 50, 30 MBH Furnace Ref. Part Part Qty. No. Description Number 48 Gas Valve- GV Junction Box Junction Box Cover Gas Pipe Gas Controls: MBH Furnace ETL Approved MBH Furnaces ETL- USA Approved (Code 07= E*) 53 GV 56 GV Ref. Part Part Qty. No. Description Number 48 Gas Valve- GV, GV3 400, 500 MBH MBH Pressure Regulator 400, 500 MBH MBH Junction Box Junction Box Cover Gas Pipe 400, 500 MBH MBH MBH Furnaces Canada Approved (Code 07= C*) GV 750 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 48 Gas Valve Body- GV 400, 500 MBH MBH Actuator Pressure Regulator 400, 500 MBH MBH Gas Pipe 400, 500 MBH MBH MBH Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

127 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Gas Train Controls GV, GV, GV4, GV5, GV MBH Furnaces GV 54 Gas Controls: 00, 50, 30 MBH Furnace Ref. Part Part Qty. No. Description Number 54 Gas Valve- GV N/S Junction Box N/S Junction Box Cover N/S= Not shown on diagram MBH Furnaces UL Approved (C07= EU, EF, EI) 6 63 GV4 GV MBH Furnaces UL Approved (C07= EU, EF, EI) GV5 GV4 GV Gas Controls: MBH Furnace UL Approved Ref. Part Part Qty. No. Description Number 54 Gas Valve- GV, GV MBH Gas Valve- GV,GV4,GV MBH Junction Box Junction Box Cover MBH Furnaces Canada Approved (C07= CC, CD) GV GV5 GV MBH Furnaces Canada Approved (C07= CC, CD) 54 GV6 GV5 GV4 GV 46 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 46 Gas Valve Body- GV 400, 500 MBH MBH Actuator- GV Gas Valve- GV4, GV MBH Gas Valve- GV4,GV5,GV MBH Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

128 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train Outlet 83 00, 50 MBH Actuator & Linkage- See next page MBH 75 Actuator & Linkage- See next page Modulating Burners Code 34= ****E*, ****R*, ****S* Ref. Part Part Qty. No. Description Number 75 Pipe w/ Valve Mount MBH MBH MBH MBH Butterfly Valve MBH , 500 MBH MBH Shutoff Valve MBH , 500 MBH MBH MBH UL MBH Canada MBH MBH 75 Hi Turn Down Burners Code 34= ****H*, ****T*, ****U* Ref. Part Part Qty. No. Description Number 75 Gas Valve MBH , 500 MBH MBH Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

129 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Damper Linkage Modulating Burners / VM Actuator Code 34= ****E*, ****R*, ****S* 97 Burner Box 95 Butterfly Valve (see previous page) 97 Burner Box 95 Butterfly Valve (see previous page) VM Actuator Switch Kit Transformer Canada Actuator Detail UL Units/Canada Units (00-30 MBH) Canada Units ( MBH) Ref. Part Furnace MBH= Qty. No. Description Actuator Motor- VM Units w/ MicroTech III Controls USA Units Canada Units Units w/ No Temp. Ctl. (Code = YC) All Units Before / All Units After / Units w/ No Temp. Ctl. (Code = YM) UL Units Canada Units Crank Arm Ball Joint Linkage Arm Crank Arm Extension Arm (Canada Units Only) Not Used Air Damper Lever Arm Gas Valve Arm Assembly part number. Motor only is p/n 3050, and Interface Kit only is p/n Assembly part number. Motor only is p/n 35780, and Switch Kit only is p/n Assembly part number. Motor only is p/n 04770, and Switch Kit only is p/n Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

130 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 00 MBH and 50 MBH Furnace Code 04= A AND Code 34= 00***, 05*** Cabinet Doors, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 649 Door Assembly Door Assembly N/S Flue Box Front Flue Box Back Flue Box Mount Sleeve Bearing Door Catch Gasket Gasket N/S Hinge N/S= Not Shown on diagram. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 30

131 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 30 MBH thru 000 MBH Furnace Code 04= A AND Code 34= 03***,040***,050***,064***,065***,079***, 080***, 00*** Cabinet Doors, Gasketing, Hardware & Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly 30, 400 MBH , 640 MBH , 790 MBH , 000 MBH Inspection Door Back- Flue Box 30, 400 MBH , 640 MBH , 790 MBH , 000 MBH Angle- Flue Box 30, 400 MBH , 640 MBH , 790 MBH , 000 MBH Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket N/S Hinge N/S= Not Shown on diagram. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

132 Section H- BlowThru Heat Blank Access Section Notes Primary Codes that pertain: 38, Additional Codes that pertain: 34, 06 Code 38 determines all of the section characteristics. If Code 38= A the section is ", if Code 38= B the section is 40", if Code 38= D, the section is 5". If Code 39= Y, there is no section. Code 34 determines the BlowThru Heat Section (Section G). If Code 34= BBBBBB then there is a 40" Blank spacer section. There has to be a Section G in order for there to be a Section H, therefore Code 34 cannot = YYYYYY. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heat Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. Cabinet Door Gasketing and Hardware Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Access Door Latching Assemblies, Key, & Lock (All Sections) Ref. Part Part Qty. No. Description Number 0 Door Latching Assy.- LH, 55" Section 40 var. 0 Door Latching Assy.- RH, 55" Section 40 var. 0 Door Latching Assy.- LH, 73" Section 4 var. 0 Door Latching Assy.- RH, 73" Section 4 var. N/S Access Door Key var. N/S Access Door Lock 0370 var. N/S= Not Shown on diagram. These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Once the door handing is determined, it is then necessary to determine the height of the section. The 55" Latching Assembly is used for unit sections 55 inches high (most sections) and the 73" assembly is used for 73" high sections (eg. Section A Energy Recovery [Code 0= *E]). 0 0 Door Latching Assy. Left Hand Door Latching Assy. Right Hand Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 3

133 Section I- BlowThru Cooling Section Notes Primary Codes that pertain: 35, 36 Additional Codes that pertain: 06 Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 40" section. If the first three digits of Code 35= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P, Y in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T the first three digits of Code 35 must equal DYY. Code 36 determines the Cooling Coil's characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Cooling section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Cabinet Door Gasketing and Hardware Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 33

134 Section I- BlowThru Cooling Section Evaporator Coil, Gasket and Drain Pans Code 35= CYYP, CYYS, CYYY AND Code 36= 5Z****, 4Z**** Unit Sizes D Unit Base 4 Ref. Part Code Part Qty. No. Description 35= Number 3 Coil- refer to the following page 3 Drain Pan- Auxiliary Drain Pan- Main Galvanized CYYY, CYYP Stainless Steel CYYS Gasket ft. Drain Pans Code 7= DYYY, DYYS- 40" Section- Unit Sizes D Diagram and Components 03 Unit Base Ref. Part Drain Pan Material Code 7= Qty. No. Description DYYY- Galvanized DYYS- Stainless 03 Drain Pan For Drain Pans and components when Code 35= GYY* and/or Code 35 Digit 4= L, T, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 34

135 Section I- BlowThru Cooling Section Evaporator Coils Unit Sizes D Typical Coil Description 4Z 08 3 D Fin Stock C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) Rows 3= 3 Row Coil 4= 4 Row Coil 5= 5 Row Coil 6= 6 Row Coil Fins-per-inch 08= 8 FPI 0= 0 FPI = FPI 4= 4 FPI Coil Model Evaporator Coils are serial number specific. Please contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 35

136 Section J- Final Filter Section Notes Primary Codes that pertain: 39 Additional Codes that pertain: 04, 33 (Mid 0 & Later), 34 Code 39 determines section characteristics. If Code 39= A, B, E, F, G, H there are filters; if C, D then there is a Blank/Empty compartment. If Code 39= Y, there is no section. Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts. Code 33 (Mid 0 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description. Unit Air Flow Cabinet Door Gasketing and Hardware (Applies to Filter OR Blank Section) Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Section Mounted Controls HL3 Gas Hi Limit Control: Code 04= A AND Code 39 DOES NOT= Y PC6 Clogged Filter Control: Code 39 DOES NOT= Y, C, D Gas Hi Limit Control Clogged Filter Control Control HL3 Gas Heat Hi-Limit (Firestat) Clogged Filter Pressure Switch- PC6 Supplied with PC6 Harness from Main/ Split Box Ref. Part Part Qty. No. Description Number 385 J Clamp- Antirotate Stat Support HL3 Firestat Junction Box Junction Box Cover Nipple Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 36

137 Section J- Final Filter Section Filter Frame, Filter Gaskets, Filters Code 39= A, B, E, F 0 0 Access Door A Unit Base 4A Ref. Part Type of Heat Qty. No. Description C39= C04= A, E C04= W, Y Filter Frame Filter Assy. w/ Gasket- 4 x 4 x " Standard A, B With intersept F N/A A Gasket Filter Assy. w/ Gasket- x 4 x " Standard A, B With intersept F N/A A Gasket Gasket- Door If Code 39= G, H contact Daikin Applied with model and serial number information so that the correct filter(s) can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 37

138 Section K- Discharge Plenum Section Notes Primary Codes that pertain: 40 Additional Codes that pertain: 06,, 5, 34, 35, 36, 38, 39, 4 Code 40 determines the discharge direction. Normally RPS units have bottom discharge (Code= B*) or side discharge (Code= SY). Normally RFS units have bottom (Code= B*), side (Code= SY), or front discharge (Code= FY). The VAV Damper option is Code *E. Code 06, insulation and liners, influences the front panels part numbers. Code, the Disconnect Switch option, influences access doors part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Codes 34-39, the BlowThru/Final Filter section codes, and Code 4, the special Blank/Empty Section code, pertain to some of the final assembly part numbers. If Code 4=Y (no blank access compartment), then the discharge plenum end panels are painted. If a Blank/Empty Section is present, then the end panels are unpainted. Note: RPS and RFS Main Control Boxes are usually located in this section. However, Main Control Box components are listed in Section N. Section Mounted Controls OAT, DAT, SD 8 8A Outside Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 8 OA Temp. Sensor A Bracket Discharge Air Temperature Sensor- DAT Main Control Box DA Opening 7A 7 Ref. Part Part Qty. No. Description Number 7 DA Temp. Sensor A Bracket Main Control Box 5 50 Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector Sampling Tube Standard Discharge Side/Top Discharge Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 38

139 Section K- Discharge Plenum Section Damper Assembly- w/ Actuator ACT5 Code 40= BE Ref. Part Part Qty. No. Description Number 30 Damper Assembly 0 x 76" w/ Act Motor Mount Damper Blade Damper Linkage Actuator Motor- ACT Damper Shaft Damper Ball Joint Damper Blade Gasket Support Retainer Bearing, sleeve flange Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 39

140 Section L- Out-of-Airstream Blank Access Section Notes Codes that pertain: 4 Additional Codes that pertain: 06 If Code 4= there is a 40" Out-Of-Airstream Blank/Empty section. If Code 4= Y, there is no Out-of-Airstream Blank/Empty Section. Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Out-of-Airstream Blank Access Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For sheet metal components that make up the Out-Of-Airstream Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Cabinet Door Gasketing and Hardware (Applies to Filter AND Blank Section) Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Section Mounted Controls LT0, REC0, S0- Section Mounted Light LT0- Blank Access Section Light/S0- Blank Access Section Light Switch/REC0- Blank Access Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 40

141 Section M- Condenser Section Notes Primary Codes that pertain: 09,, 43, 44, 47, 54, 68 Additional Codes that pertain: 7, 8, 4, 45 This section houses the Compressors, Condenser Coils, Condenser Control Box (RCS units only), Pressure controls, and Fan Deck. The Compressor high and low pressure controls as well as the fan pressure controls are always located in this section. RCS units have the pressure controls mounted on the Control Box Manifold (SpeedTrol Inverters and Line Reactors are in the Control Box). RPS units have the pressure controls as well as SpeedTrol Inverters and Line Reactors (if supplied) in a box mounted where the air handler and condensing unit attach. Code 09, unit voltage, affects Compressor Contactors and Motor Protectors (located in the Condenser Control Box for RCS units) as well as the Compressor selection. Code determines whether there is a MicroTech III Unit Controller present or if the unit is not provided with a factory installed controller. Code 43 determines if the Micro Channel Condenser Coils are coated or not, and if the unit is equipped with Coil/Vandal Guards AND/OR Sealtite conduits. Code 44 shows the type of compressor selected. Code 44= R NORMALLY stands for units with ALL standard scroll compressors. For units with Inverter Compressors (Code 44= V, W) refer to form (Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY.) Starting in late 04, some units are built as specials with digital scroll compressors with Code 44= R AND Code 60= XX with digital scroll compressors listed as a special feature (refer to the drawing below for an example of Special Code String Text). Confirm the presence of a digital compressor BEFORE ordering to ensure that the correct part(s) are identified. Code 44= D also indicates the presence of digital compressors. Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47=, 3), or SpeedTrol [Low Ambient operation] (Code 47=, 4). If Code 47= 3, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

142 Section M- Condenser Section Notes, Continued Code 54 indicates that Modulating Hot Gas Reheat was chosen. This option alters the number of Variable Speed Condenser motors and the Condenser Fan circuiting in the Main Control Box. Code 68 specifies the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at 0 SCCR (Code 68= 0, OR no entry). An entry with any other rating (Eg: Code 68=, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 7 determines whether the RCS control box has Ground Fault and/or Phase Failure capability. Code 8 determines if there is a unit powered Receptacle, and associated controls. Code 4 indicates Compressor capacity control. Code 45 determines the way the Compressor is mounted. If Code 45= Y the unit must be an RFS. The Condenser Coil Compartment, and the Compressor Compartment components are different for RPS and RCS units. All other aspects of the section (Fan Deck, Compressors, etc.) are identical. The Condenser Section is integral to the RPS unit, but is not used on the RFS. An RCS unit is a condensing unit only. RCS units can either be used as a Stand Alone Condenser unit, or used in conjunction with an RFS. For information specific to RCS Standalone Units (RCS05-040D units when Code = *A), refer to RPL form NOTE: This form is to be used for RCS units when Code = DOES NOT= *A. For RCS05-040D units when Code = *A refer to form # Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 4

143 Section M- Condenser Section Fan Deck, Coil Guard Diagrams Unit Sizes 05-06D Standard Fan Deck End of Unit 05, 00, 05D Fan Deck shown Coil Guards (Code 43= *G) End of Unit Typical. RPS unit shown. A 0 Fan Layout Detail Fan # Fan # Fan # Fan # End of Unit 05, 00, 05D Fan Deck Detail Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" End of Unit 06, 0, 06D Fan Deck Detail Rev. AN 05/8 RPL / Page 43

144 Section M- Condenser Section Fan Deck, Coil Guard Diagrams Unit Sizes D Standard Fan Deck 55 Coil Guards (Code 43= *G) End of Unit Typical. RPS unit shown. 0 Fan Layout Detail Fan # Fan # End of Unit Fan # Fan # 030, 03, 035, 040, 04D Fan Deck Detail Rev. AN 05/8 CDF60 CDF50 Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" RPL / Page 44 CDF5 CDF53

145 Section M- Condenser Section Standard Condenser Fan Components Code 47=, Unit Size Ref. Part Part 05 06/ No. Description Number Panel, Blank Fan Deck Panel Condenser Motor 08/30/ FanTrol/SpeedTrol Code 47=, Condenser Motor FanTrol/SpeedTrol Code 47=, Condenser Fan Motor Mount Condenser Fan Prop Condenser Fan Guard The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications when Code 47= OR. This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 45

146 Section M- Condenser Section Quiet Fan Assembly Code 47= 3, 4 Unit Size Ref. Part Part No. Description Number Quiet Fan Assembly 08V V Panel, Blank Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor Mount, and Fan Top Panel are NOT available separately. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 46

147 Section M- Condenser Section Compressors Circuit #: Code 44= R OR D 3 Standard AND Digital Scroll Compressor Units: Circuit # 3 08/30V Unit Size /30V Ref. Part No. Number /5 & Earlier /5 & Later /4 & Earlier /5 & Later /5 & Earlier /5 & Later RPS Units only (T) /0 & Earlier /0 thru 6/ (T) 7/5 & Later (T) 0/0 & Earlier /0 thru 6/ (T) 7/5 & Later (T) /0 & Earlier /0 thru 6/ (T) 7/5 & Later RCS Units only (T) /0 & Earlier /0 & Later (T) 0/0 & Earlier /0 & Later (T) /0 & Earlier /0 thru 6/5 (T)= Tandem compressor assembly. For units built between the dates indicated, contact Daikin Applied with model and serial number information to ensure that the correct compressor is identified. Note that these compressors are NOT drop in substitutions for each other because the piping connections are NOT in the same location. Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). It is important to note that CIRCUIT # COMPRESSORS ARE ALWAYS STANDARD SCROLLS. 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 47

148 Section M- Condenser Section Compressors Circuit #: Code 44= R OR D, Continued Standard AND Digital Scroll Compressor Units: Circuit # 08/30V Unit Size /30V Ref. Part No. Number RPS Units only (T) /0 & Earlier /0 & Later (T) 09/0 & Earlier /0 & Later RCS Units only (T) /0 & Earlier /0 & Later (T) 09/0 & Earlier /0 & Later (T) /0 & Earlier /0 & Later (T) 0/0 & Earlier /0 & Later (T) /0 & Earlier /0 & Later (T) 9/0 & Earlier /0 & Later (T)= Tandem compressor assembly. Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). It is important to note that CIRCUIT # COMPRESSORS ARE ALWAYS STANDARD SCROLLS. 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 48

149 Section M- Condenser Section Compressors Circuit #: Code 44= R 3 Standard Scroll Compressor Units: Circuit # 3 08/30V Unit Size /30V Ref. Part No. Number A A 36330(T) 5/5 & Earlier (T) 6/5 & Later 36330(T) 4/5 & Earlier (T) 7/5 & Later (T) 5/5 & Earlier (T) 0/5 & Later A 36340(T) 36340(T) (T) A (T) (T) (T) RPS Units only A (T) 8/0 & Earlier /0 thru 5/ (T) 6/5 & Later (T) 0/0 & Earlier /0 thru 6/ (T) 7/5 & Later RCS Units only A (T) /0 & Earlier /0 & Later (T) 0/0 & Earlier /0 & Later (T)= Tandem compressor assembly. For units built between the dates indicated, contact Daikin Applied with model and serial number information to ensure that the correct compressor is identified. Note that these compressors are NOT drop in substitutions for each other because the piping connections are NOT in the same location. Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). For units with a Digital Compressor in Circuit #, refer to two pages after next. 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 49

150 Section M- Condenser Section Compressors Circuit #: Code 44= R, Continued 3 Standard Scroll Compressor Units: Circuit # 3 08/30V Unit Size /30V Ref. Part No. Number RPS Units only A (T) 8/0 & Earlier /0 & Later (T) 9/0 & Earlier /0 & Later (T) RCS Units only A (T) 0/0 & Earlier /0 & Later (T) 0/0 & Earlier /0 & Later (T) 4/0 & Earlier /0 & Later A (T) 8/0 & Earlier /0 thru 3/ /5 & Later (T) /0 & Earlier /0 thru 4/ /5 & Later (T) 9/0 & Earlier /0 thru 6/ /5 & Later (T)= Tandem compressor assembly. For units built between the dates indicated, contact Daikin Applied with model and serial number information to ensure that the correct compressor is identified. Note that these compressors are NOT drop in substitutions for each other because the piping connections are NOT in the same location. Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). For units with a Digital Compressor in Circuit #, refer to one page after next. 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 50

151 Section M- Condenser Section Compressor Crankcase Heaters & Compressor Mounting: Code 44= R 3 Standard Scroll Compressor Crankcase Heaters Part Number Unit Unit Unit Date Compressor Compressor Compressor Compressor Size Voltage Type Used /06 ALL ALL ALL N/A N/A 00/0 08/30 ALL 5/5 & Earlier N/A /0 08/30 ALL 6/5 & Later N/A /0 460 ALL 9/4 & Earlier N/A /0 460 ALL 7/5 & Later N/A /0 575 ALL 6/5 & Earlier N/A /0 575 ALL 0/5 & Later N/A /06 ALL ALL ALL N/A /03 ALL ALL ALL N/A ALL RPS 5/5 & Earlier ALL RPS 7/5 & Later ALL RCS ALL ALL ALL ALL ALL RPS 6/5 & Earlier ALL RPS 7/5 & Later N/A= Not available. One Crankcase heater is used per compressor. Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). For units with a Digital Compressor in Circuit #, refer to the following page. 4 For units built during the transition, contact Daikin Applied with model and serial information to ensure that the correct heater is identified. Standard Scroll Compressor Mounting Due to the number of different mounting options used during production, contact Daikin Applied with model and serial number information to ensure that the correct mounting components are identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

152 Section M- Condenser Section Compressors Circuit #: Code 44= R OR D & Compressor Crankcase Heaters Digital Scroll Compressor Units: Circuit # 08/30V Unit Size Ref. Part No. Number N/S (D) (D) N/A (D) (D) N/A (D) (D) N/A (D) (D) N/A (TD) (TD) N/A (D) (D) N/A N/S= Not shown on diagram. (D)= Digital compressor. (TD)= This is a Tandem compressor assembly with one () Digital and one () Standard Scroll. To determine whether to replace the tandem OR ONE OF THE compressors in the tandem assembly contact Daikin Applied. N/A= Digital Scroll Compressors are not currently available. Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). It is important to note that DIGITAL COMPRESSORS ARE ALWAYS LOCATED IN CIRCUIT #. 08/30V 08/30V 08/30V 08/30V 08/30V Digital Scroll Compressor Units Crankcase Heaters Part Number Unit Unit Compressor Compressor Compressor Compressor Size Voltage All N/A N/A N/A 00 All N/A N/A All N/A N/A All N/A N/A All N/A 3 N/A All N/A N/A N/A= Not available. One Crankcase heater is used per compressor. 3 The position of the Digital Scroll Compressor varies. Confirm which compressor requires a new heater and contact Daikin Applied with model and serial number information to ensure that the correct part is identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 5

153 Section M- Condenser Section Digital Scroll Compressor Components & T, T3 Transformers/Fusing CDT, SV Control Box Detail Digital Compressor Detail Unit Size Ref. Part Part No. Description Number Thermistor, Discharge (CDT) Thermistor, Discharge (CDT) Strap, Thermistor Kit, Valve/Coil/Tubing, 4V (SV7) Kit, Unloader Coil, 0V (SV7) Kit, Valve/Coil, 4V (SV7) FA, B Fuse- T Primary 08V FC Fuse- T Secondary 4EHG7663 T Transformer- 5/4V 08V N/S Cover- Terminals N/S Cover/Fuseholder T3 Transformer- 5/4VAC N/S Compressor Mounting Kit N/S= Not shown on diagram. Note that 00, 0D units can be built with EITHER a 0V OR a 4V coil. Confirm the voltage of the coil required BEFORE ordering, or contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. For voltages not shown contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 53

154 Section M- Condenser Section Condenser Coils, Pressure Controls, Coil & Vandal Guards Ref. Part Part Unit Size No. Description Number Condenser Coils Code 43= M* N/S 7" x 48" 6/3 & Earlier " x 48" 7/3 thru 4/ " x 48" 5/4 & Later " x 93" 7/3 & Earlier " x 93" 8/3 & Later Condenser Coils Code 43= T* N/S 7" x 48" " x 93" Condenser Coils, Coated Code 43= P* N/S 7" x 48" 6/3 & Earlier " x 48" 7/3 & Later " x 93" 0/3 & Earlier " x 93" /3 & Later Condenser Coils, Coated Code 43= U* 7" x 48" " x 93" N/S Pressure Switches Low Pressure FanTrol Unit Code 47=, SpeedTrol Units Code 47=, High Pressure Coil Guard RPS Side Side RCS Side Coil Guard- RPS Only Side- Control Box Side- Control Box Side- Control Box Coil/Tube Guard N/S Vandal Guard Kit RPS RPS RCS N/S= Not shown on Diagram. Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. 3 Starting 04/5 ALL 06D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 54

155 Section M- Condenser Section Condenser Coils, Pressure Controls, Coil & Vandal Guards, Continued Ref. Part Part Unit Size No. Description Number Condenser Coils Code 43= M* N/S 7" x 7" 7/3 & Earlier " x 7" 8/3 & Later " x 93" 7/3 & Earlier " x 93" 8/3 & Later Condenser Coils Code 43= T* N/S 7" x 7" " x 93" Condenser Coils, Coated Code 43= P* N/S 7" x 7" 7/3 & Earlier " x 7" 8/3 & Later " x 93" 0/3 & Earlier " x 93" /3 & Later Condenser Coils, Coated Code 43= U* N/S 7" x 7" " x 93" N/S Pressure Switches Low Pressure FanTrol Unit Code 47=, SpeedTrol Units Code 47=, High Pressure SpeedTrol Pressure Code 47=, Pressure Transducer Harness N/S Line Reactor- SpeedTrol () Code 47=, Coil Guard RPS Side Side RCS Side Side Coil Guard- RPS Only Side- Control Box Side- Control Box Side- Control Box Coil/Tube Guard N/S Vandal Guard Kit RPS RPS RCS N/S= Not shown on Diagram. Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. 3 Starting 04/5 ALL 03D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 55

156 Section M- Condenser Section Pressure Controls: (03/03 & Earlier) AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 RPS Units Only 44 HP PC SPTRL typ PC3 AFD AFD 35 HP 46 LP SPTRL LP LR LR Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, AFD, Inverter 08/30V Inverter Inverter LR, Line Reactor only (Code 09= 37) This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 38, 39) in place of each of the SPTRL Switches. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 56

157 Section M- Condenser Section Pressure Controls: (04/03 & Later) AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 RPS Units Only See Factory Supplied Line Voltage Box Section Ref. Sch. Part Part Qty. No. Sym. Description Number 33, 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, , 44 VFD, SpeedTrol VFD Code 54= YY 08/30V, HP , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V 93554, 3HP On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 38, 39) in place of each of the SPTRL Switches. Note that ABB brand VFDs are offered as STANDARD. Confirm brand of VFD required BEFORE ordering or contact Daikin Applied. The replacement ABB brand VFD Keypad is p/n For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 57

158 Section M- Condenser Section Pressure Controls- Manifold Mounted HP, HP, LP, LP, SPTRL RCS Units Only Circuit # Circuit # SpeedTrol (Code 47=, 4) SpeedTrol (Code 47=, 4) FanTrol (Code 47=, 3) FanTrol (Code 47=, 3) Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, For RCS units, the SpeedTrol Inverters- AFD, AFD (and Line Reactors for units) are located in the RCS Control box, and the pressure controls for the Compressor and FanTrol are located on the control box manifolds. This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 58

159 Section M- Condenser Section Pressure Controls- Manifold Mounted, Digital Compressor Units HP, HP, LP, LP, SPTRL, Continued Circuit # Circuit # Speedtrol (Code 47=, 4) Speedtrol (Code 47=, 4) Ref. Sch. Part Part Qty. No. Sym. Description Number 33 PC9 Switch, Pressure, Coil Splitter LP, Switch- Low Pressure Speedtrol Unit Code 47=, HP, Switch- High Pressure SPTRL Switch- Speedtrol Pressure Code 47=, SPTRL Switch- Speedtrol Pressure Code 47=, Valve Core Valve Cap Pressure Switch Harness 7" Pressure Switch Harness 44" Pressure Switch Harness 36" Confirm cable length required BEFORE ordering. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 59

160 Section M- Condenser Section Condenser Control Box (RCS Units Only) No Controls: Code = YM Diagrams RCS with no controls: Code = YM 03/03 & Earlier PL5- PL30 Plugs RCS with no controls: Code = YM 04/03 & Later PL5- PL30 Plugs For more information on RCS Standalone Units (Code = YA, A, A) refer to form # The above diagrams show typical Condenser Control Box layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 60

161 Section M- Condenser Section Condenser Control Box (RCS Units Only) MicroTech III Controls Code = *E, *F, *W Diagrams RCS with MicroTech III Controls: Code = *E, *F, *W 03/03 & Earlier PL5- PL30 Plugs RCS with MicroTech III Controls: Code = *E, *F, *W 04/03 & Later PL5- PL30 Plugs The above diagrams show typical Standard Scroll Compressor Control Panel layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

162 Section M- Condenser Section Condenser Control Box RCS Components Ref. Part Part Unit Size No. Description Number DCC Digital Compressor Controller S Switch- System REC Receptacle Time Delays (Code = YM) TD, Time Delays, Compr. Lockout 6 TC Temperature Control- FanTrol Ground Fault Protection GFR4 Ground Fault Relay- SPDT GFS4 Ground Fault Sensor Phase Voltage Monitor (PVM) PVM4 08/30/ (/6 & Earlier) 000 (/6 & Earlier) /30/ (/7 & Later) (/7 & Later) Socket, PVM (/7 & Later) PL5-30 Plugs- Pin T9 Transformer- 5/4VAC Terminal Blocks TB Terminal Block TB3, 5, 6, 8 Terminal Block TB35 Terminal Block Assy TB36 Terminal Block Assy Contactors/Motor Protectors M- 4 Contactor- Compressors 3 M- M Contactor- Fan Motors 3 MMP- 4 MMP- Compressors 3 MMP, MMP- Fan Motors 3 Power Block PB4 Power Block, Main 75A A, 40A Relays R Relay- Hi Pressure Reset R Relay- Hi Pressure Reset R5 Relay- Safety R6 Relay- Safety R7 Relay- Safety R8 Relay- Safety R Relay- Condenser Fan R3-36 Relay- Compressor Staging R70-90 Relays- Digital Compressor Varies depending on unit options. Part number is for one individual section. Ground block is p/n Varies depending on unit options. Part number is for one individual section. Ground block is p/n Even though these components are installed in the RCS unit Condenser Control Box, Compressor and Condenser Fan Motor Contactors, Manual Motor Protectors and associated parts are detailed in the Main Control Box Section (Section N). 4 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure that the correct part(s) are identified. 5 Varies depending on unit options. 6 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n The ADJUSTABLE version of this relay could also have been supplied: p/n Confirm which relay is required BEFORE ordering. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 6

163 Section M- Condenser Section Condenser Control Box RCS Components, Continued Disconnect Switches 03/03 & Earlier Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS4 Disconnect Switch- Condenser Control Box Switch- 00A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS4 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Disconnect Switches 04/03 & Later Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS4 Disconnect Switch- Condenser Control Box Switch- 00A Handle 9340 Shaft Switch- 50A Handle 9340 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS4 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 3 This shaft is 4.5 OAL and is designed to be cut to length in the field. 4 This shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 63

164 Section M- Condenser Section Factory Supplied Line Voltage Box- Powered Receptacle and Lights T6, DS6, FU6A, FU6B, FU6C: Code 8= U***, V*** OR Code 3= ***F* 03/3 & Earlier T6 DS6 8 L L L3 9 3 FU6C FU6B FU6A T T T3 Voltage Ref. Sch. Part Part No. Sym. Description Number T6 Transformer KVA Transformer KVA Transformer KVA DS6 Disconnect Switch 30A/600V FU6A,B Fuse 0A/600V Fuse 0A/600V Fuse 8A/600V FU6C Fuse 0A/600V V 30V 0 04/3 & Later 0 TB7 DS6 Main Control Box Typical Pressure Controls Box Voltage Ref. Sch. Part Part No. Sym. Description Number 0 DS6 Fuse Holder/Circuit Protector P, 30A, 600V FU6A, B Fuse 0A/600V Fuse 0A/600V Fuse 8A/600V TB7 Terminal, x Green Terminal Block End Plate Terminal, x Grey Terminal Block End Stop Grey T6 Transformer KVA Transformer KVA Transformer KVA Terminal Cover Kit FU6C Fuse 0A/600V V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 64

165 Section N- Main Control Box Notes Primary Codes that pertain: 09,,, 3, 4, 5, 7, 8, 44, 47 and 3, 54, 68 Additional Codes that pertain: 04, 9, 0,, 7, 3, 34, 35, 40 The Main Control Box applies to RPS & RFS units. RCS units have their own Controls that are detailed in Section M. The Main Control Box is normally mounted in the Discharge Plenum Section (Section K) and is comprised of three primary parts The Dead front Door with Keypad, the Control Panel, and the Power Panel. In March and April of 03, the Main Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and VFD circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable. For units built and shipped during the transition, confirm which design was used, or contact Daikin Applied to ensure that the correct part(s) are identified. Code 9 determines unit voltage and affects the Transformers, Motor Protectors/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Terminal Block or a through-the-door Disconnect Switch. Code determines which type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, or None) and whether the unit uses Discharge Temperature, Space Control, or Zone control. There is an MCB and separate Expansion Boards in the control panel. Units may also have no unit controls (Code = YM, YC) in which case the Main Control Box has no MCB or Expansion boards, but instead has a set of Relays. Code 3 determines the presence of Duct and/or Space Sensors. Codes 4 and 5 determine the Supply AND Return Fan Inverter specifications. Code 7 AND/OR 3 (Mid 0 & Later) determine electrical options including a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc. Code 8 indicates whether a unit has a Remote Keypad Display AND/OR a unit mounted Receptacle. Code 44 shows the type of compressor selected. Code 44= R NORMALLY stands for units with ALL standard scroll compressors. For units with Inverter Compressors (Code 44= V, W) refer to form (Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY.) Starting in late 04, some units are built as specials with digital scroll compressors with Code 44= R AND Code 60= XX with digital scroll compressors listed as a special feature (refer to the drawing below for an example of Special Code String Text). Digital Compressors may add/change some Control Box components so confirm the presence of a Digital Compressor BEFORE ordering to ensure that the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 65

166 Section N- Main Control Box Notes, Continued Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47=, 3), or SpeedTrol [Low Ambient operation] (Code 47=, 4). If Code 47= 3, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. See Code 54 below. Code 54 (Mid 0 & Later) indicates that Modulating Hot Gas Reheat was chosen. This changes Condenser Fan circuiting by adding fusing and AFD/VFD fan control independent of Code 47. Code 68 specifies the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at 0 SCCR (Code 68= 0, OR no entry). An entry with any other rating (Eg: Code 68=, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Codes 9, 0, are return air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc, have an impact on Contactors, Motor Protectors, Fuses, and Duct Sensors. Code 7 determines the DrawThru section, and can impact the Cooling Circuit Relays. Code 3 determines horsepower for the Supply Fan Motor which, like the Return Air Motor affects Contactors, Fuses, Motor Protectors, etc. Codes 04, 34, and 35 determine the BlowThru section, and the heat type, which impact Transformers, Heat Circuit Relays, and Cooling Circuit Relays. Code 40 determines if there is a VAV Damper and related Control Relay. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 66

167 Section N- Main Control Box Control Panel- MicroTech III Control Box Component Label Diagram Note that starting in late 00 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 67

168 Section N- Main Control Box Control Panel Units with No Controller (Code = Y*) Diagram Left Side Door (see detail below) R R R 0 R R 4 5 R R 8 9 R 63 R 5. R 6. R 7. R 8. R R 9 0 R 67 R 68 R 69 R 70 R R R 7 3. R 4. TD TD DHL See Power Panel T4 T Left Side Door Detail HS S CS CS S4 S7 Switch Detail The above diagram shows a typical Standard Scroll Compressor Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 68

169 Section N- Main Control Box Control Panel Units with No Controller (Code = Y*) Components Sch. Part Part Qty. Sym. Description Number Digital Compressor Controller DCC Digital Compressor Controller Relays R, Relay- Hi Pressure Reset R Relays- Safety R9, R0 Relay- Compressor Lockout R,R Relay- SpeedTrol Fan Cycling (036, 040 only) Code 47=, R8, R9 Relay- Cooling Failure Indicator R0 Relay- Steam or Hot Water Heat Code 04= S, W Relay- Electric Heat Code 04= E Relay- Gas Heat Code 04= A Units w/no Controller & Gas Actuator Code = YC Hi Turn Down Burner Code 34 (5th digit)= H,T,U Modulating Burner Code 34(5th digit)= E,R,S Units w/no Controller & Float Control Code = YM Hi Turn Down Burner Code 34 (5th digit)= H,T,U Modulating Burner Code 34(5th digit)= E,R,S R4 Relay- Gas Heat Alarm Code 04= A R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R6 Relay- Iso Damper- Open/Close R30 Relay- Cool Valve w/ Face Bypass R4-43 Relays- Condenser Fan R45 Relay- UV Lights R46 Relay- Inverter, Supply Fan increase/decrease Code 4= -3, R48 Relay- Inverter, Return Fan increase/decrease Code 4=,4,5, R58 Relay- Heat Wheel increase/decrease Code 4= F R60 Relay- Heat Wheel Enable R63 Relay- Specials R66 Relay- Return Air Smoke Detector Code 6=, R67 Relay- Supply Fan Enable No Controller w/o Inverter or w/inverter/no Bypass C= YM, YC No Controller w/ Inverter and Bypass C= YM, YC R68 Relay- Return Fan Enable R69 Relay- Inverter Bypass VAV Interlock Code 4= R70-90 Relays- Specials/Digital Compressor Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS Pressure Transducer- Duct Sensor Code 3=,, SPS Pressure Transducer- Duct Sensor Code 3= Pressure Transducer- Space Sensor Code 3= 3, Transformers- Controls T Transformer- Control Input 5-4V With Controller Code = *D, *S No Controller Code = YM, YC T3 Transformer- Control Output 5-4V T4 Transformer- Exhaust Damper Actuator 5- VDC T9 Transformer- Refrigerant Circuit 4V Varies depending on unit options. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 69

170 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code = *E, *F, *W): (03/03 & Earlier) Diagram See Power Panel The above diagram shows a typical Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 70

171 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code = *E, *F, *W): (03/03 & Earlier) Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad/Interface Display Expansion Module EXP A Expansion Module- Condenser/ Energy Recovery EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Hot Gas Reheat Code 48= H, K RHB, Interface Boards, Modulating Hot Gas Reheat Communication Card COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge (Code = LE, LW) LonWorks- Constant Volume (Code = LF) Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat FS 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/0A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Receptacle REC Receptacle Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer Kit- Duct Sensor (9/ & Earlier) 3, Pressure Transducer- Duct Sensor (0/ thru 3/3) Pressure Transducer Kit- Space Sensor (9/ & Earlier) 3, Pressure Transducer- Space Sensor (0/ thru 3/3) Not Shown on diagram. Quantity varies depending upon unit options selected. 3 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. 4 As of 09/ the original Pressure Transducer is no longer available. The Transducer Kit includes Transducer, Dinrail, Resistor, Sampling Tube, and installation Instructions. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

172 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code = *E, *F, *W): (03/03 & Earlier) Components Sch. Part Part Qty. Sym. Description Number Relays R Relay- Condenser Fan R4 Relay- Condenser Fan R0 Relay- Heat R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y R8 Relay- Smoke 4P/6A/4V R8 Relay- Smoke 4P/6A/4V R83 Relay- Smoke 4P/6A/4V R84 Relay- Smoke 4P/6A/4V R85 Relay- Smoke 4P/6A/4V R86 Relay- Smoke 4P/6A/4V R87 Relay- Smoke 4P/6A/4V R88 Relay- Smoke 4P/6A/4V Time Delay TD0 Time Delay 0 Second Terminal Block TB Terminal Block Sensors ZNT Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., SHS Sensor, Humidity Duct Mounted DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only- Code = *F, *W. 3 Not shown on diagram. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 7

173 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code = *E, *F, *W): (04/03 & Later) Diagram PL - PL43 Plugs See Power Panel See Power Panel The above diagram shows a typical Standard Scroll Compressor Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 73

174 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code = *E, *F, *W): (04/03 & Later) Components Sch. Part Part Qty. Sym. Description Number Controllers MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad/Interface Display DCC Digital Compressor Controller Expansion Modules EXP A Expansion Module- Condenser/ Energy Recovery EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Hot Gas Reheat Code 48= H, K OR Code 54= BM RHB, Interface Boards, Modulating Hot Gas Reheat Communication Cards COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge Code = LE, LW LonWorks- Constant Volume Code = LF Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat FS 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/0A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V T7 Transformer- Hot Gas Reheat 0-4V Receptacle REC Receptacle Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer- Duct Sensor Pressure Transducer- Space Sensor Snubber, Pressure Transducer (optional; field installed) Not Shown on diagram. Quantity varies depending upon unit options selected. 3 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 74

175 C F Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code = *E, *F, *W): (04/03 & Later) Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- Condenser Fan R4 Relay- Condenser Fan R0 Relay- Heat R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y R70-90 Relays- Specials/Digital Compressor vars. R8-88 Relays- Smoke 4P/6A/4V vars. Time Delays TD0 Time Delay 0 Second TD9 Time Delay, Coil Splitter Terminal Blocks TB Terminal Block TB35 Terminal Block Assy TB36 Terminal Block Assy Sensors 3 ZNT Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., SHS Sensor, Humidity Duct Mounted /6 & Earlier Sensor, Humidity Duct Mounted /7 & Later Sensor, Humidity Wall Mounted DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only (Code = *F). 3 Not Shown on diagram. 4 In late 03, Digital Room Sensor p/n was added as the preferred option. The other Zone Temperature Sensors are still available as options. For positive p/n identification, refer to the drawings below.. ZNT Sensor ZNT Sensor 3770 ZNT Sensor 3780 Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 75

176 Section N- Main Control Box Power Panel: (03/03 & Earlier) Diagram See Control Panel See Control Panel PL - PL43 Plugs See Control Panel The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 76

177 Section N- Main Control Box Power Panel: (03/03 & Earlier) Terminal Blocks, T Transformer, Fuses Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB Terminal Block TB, 3, 4, 7 Terminal Block Transformer- Main 3 T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= Units with UV Lights Code 7 (nd digit)= FC Fuse- T Transformer Fuse- T Transformer Fuse- T Transformer Varies depending on unit options. Part number is for one individual section. Ground block is p/n Jumpers are p/n (TBA:5), (TBB:4), (TBC:0, TBD:5 & TBE:30). Varies depending on unit options. Part number is for one individual section. Ground block is p/n T Transformers use Fuse Puller Kit p/n & Cover Kit p/n Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; 04753= Non- Gas Heat Units with no UV lights. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 77

178 Section N- Main Control Box Power Panel: (03/03 & Earlier) Fuses, Ground Fault Protection, Phase Protection (PVM, ), Power Supply, Power Blocks Sch. Part Part Voltage Sym. Description Number 08V 30V Fuses F,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor Code 04= A F5 Fuse- UV Lights Code 7 (nd digit)= Ground Fault Code 7 [nd digit]= G, B, C, D, K GFR Ground Fault Relay- SPDT GFS Ground Fault Sensor Phase Voltage Code 7 [nd digit]= P, A, C, D, H, J, K PVM, Phase Voltage Monitor 000 Phase Voltage Monitor 000 Power Blocks PB Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat , 60, 80, 00, 0, 40 KW Electric Heat PB0 Power Block- Supply Fan Code 5= F PB0 Power Block- Return Fan Code 5= F Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure that the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 78

179 Section N- Main Control Box Power Panel: (03/03 & Earlier) Disconnect Switches, Plugs Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS Disconnect Switch- Main Code = A Switch- 00A RPS Switch- 00A RFS Shaft, Mod Handle w/ Operating Mechanism Ground Lug Switch- 50A RPS Switch- 50A RFS Shaft, Mod Handle w/ Operating Mechanism Ground Lug Switch- 50A RPS Switch- 50A RFS Shaft, Mod Handle w/ Operating Mechanism Ground Lug Switch- 400A RPS Switch- 400A RFS Shaft, Mod Handle w/ Operating Mechanism Ground Lug Switch- 600A Shaft, Mod Handle w/ Operating Mechanism Ground Lug Plugs Pin Plug varies varies varies varies 4 6 Pin Plug varies varies varies varies 5 Pin Plug varies varies varies varies 6 3 Pin Cap Kit varies varies varies varies 7 6 Pin Cap Kit varies varies varies varies 8 9 Pin Cap Kit varies varies varies varies 9 5 Pin Cap Kit varies varies varies varies Any of the listed disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure that the correct part(s) are identified. The listed disconnects apply to RFS units with Steam Heat, HW Heat, Gas Heat OR No Heat. RFS units with Electric Heat use the same Disconnects as RPS units. 3 Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 4 Used with strain relief (p/n ) & 6 pin cap kit (p/n ). Used for PL0, PL. 5 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use strain relief p/n & cap kit p/n ). 6 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 7 Used for PL9, PL0. 8 Used for PL8, PL9, PL35, PL36, PL43. 9 Used for PL7, PL8. 0 All possible plugs used are listed. Check actual unit to verify which plug is required. The original type "N" disconnect is obsolete 3/0. Due to size differences, minor field modifications may be required for proper installation. Only for use with new style disconnect for units built after 3/0. If replacing the handle assembly for a unit built before 3/0, use handle p/n: Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 79

180 Section N- Main Control Box Power Panel: (03/03 & Earlier) Circuit Breakers Sch. Part Part Voltage Sym. Description Number 08V 30V Circuit Breakers CB0 CB0 Circuit Breaker- Supply Fan Circuit Breaker- Return Fan Motor HP=,.5,, Motor HP=,.5,, 3, 5, 7.5, Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= 0, Motor HP= Motor HP= Motor HP= CB60 Circuit Breaker- Heat Recovery Wheel Circuit Breaker- Heat Recovery Wheel Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 80

181 Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply MMP0 & M0 Fan Contactor and Return MMP0 & M0 Fan Contactor Diagrams MMP 3 3E Front Mounted Aux. Contact Aux. Contact Front Mtd. Aux. Contact 3D Link 3E 3B 3 MMP Contactor Short Circuit Alarm 3D Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail HP Motors- All Voltages 0 HP Motor- 30/460/ 5, 0 HP Motor- 460/ 5 HP Motor- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 0HP Motor- 08V 5HP Motor- 08/30V 0 HP Motor- 08/30V 5 HP Motor- 30/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Lug 3G MMP 3 Trip Indicator Alarm 3F Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motor- 08V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

182 Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply MMP0 & M0 Fan Contactor and Return MMP0 & M0 Fan Contactor Components HP Motor- Code OR 3= E*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V.5 HP Motor- Code OR 3= F*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V HP Motor- Code OR 3= G*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 8

183 Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply MMP0 & M0 Fan Contactor and Return MMP0 & M0 Fan Contactor Components, Continued 3 HP Motor- Code OR 3= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 5 HP Motor- Code OR 3= J*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 7.5 HP Motor- Code OR 3= K*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 83

184 Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply MMP0 & M0 Fan Contactor and Return MMP0 & M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 5 HP Motor- Code OR 3= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 84

185 Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply MMP0 & M0 Fan Contactor and Return MMP0 & M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 5 HP Motor- Code 3= P*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link E Front Mtd. Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) A 5HP Supply Fan Motor is only available when Code 3= 4**. A 5HP Motor is not available for Return Fan applications. 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 85

186 Section N- Main Control Box Power Panel: (03/03 & Earlier) Compressor MMP, MMP and Contactor M, M Unit Size 05D Front-Mounted Aux. Contact 3E or 4E 3 or 4 MMP Link 3B or 4B Front-Mounted Aux. Contact E or E Spacer 3A or 4A Contactor or Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors M Contactor- Compressor # Contactor- Compressor # E Front Mtd. Aux. Contact- NO AND NC M Contactor- Compressor # Contactor- Compressor # E Front Mtd. Aux. Contact- NO AND NC Compressor MMP's & Parts 3 MMP Manual Motor Protector- Compressor # Manual Motor Protector- Compressor # A Spacer B Link E Front Mtd. Aux. Contact- NO OR NC MMP Manual Motor Protector- Compressor # Manual Motor Protector- Compressor # A Spacer B Link E Front Mtd. Aux. Contact- NO OR NC V 05 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 86

187 Section N- Main Control Box Power Panel: (03/03 & Earlier) Compressor MMP,, 4 and Contactor M,, 4 Unit Sizes 00-03D MMP 4 Front-Mounted Aux. Contact Link 3E or 4E 3B or 4B 3 or MMP 4 Front-Mounted Aux. Contact 4E Contactor Contactor or MMP & M or MMP3 & M3 Link Detail- All Voltages MMP & M Link Detail- 460/, Unit Size 05 MMP & M Link Detail- 08/30V, Unit Sizes 05, 030 MMP & M Link Detail- 460/575, Unit Size 030 Unit Size 00, 0 05, , 03 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors M Contactor Contactor Contactor Contactor M, 4 Contactor Contactor Contactor Contactor Comp. MMP's & Parts 3 MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP E Aux.- Front Mounted MMP, 4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP E Aux.- Front Mounted V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 87

188 Section N- Main Control Box Power Panel: (03/03 & Earlier) Compressor MMP thru 4 and Contactor M thru 4 Unit Sizes D MMP 4 Front-Mounted Aux. Contact Link 3E or 4E 3B or 4B 3 or MMP 4 Front-Mounted Aux. Contact 4E Contactor Contactor or MMP & M Link Detail- All Voltages MMP3 & M3 Link Detail- All Voltages MMP & M Link Detail- 460/ MMP4 & M4 Link Detail- 460/ MMP & M Link Detail- 08/30V MMP4 & M4 Link Detail- 08/30V Unit Size Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors M, 3 Contactor Contactor M, 4 Contactor Contactor Comp. MMP's & Parts 3 MMP, 3 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP E Aux.- Front Mounted MMP, 4 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP E Aux.- Front Mounted V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 88

189 Section N- Main Control Box Power Panel: (03/03 & Earlier) Condenser Fan Contactors, MMPs, & Fusing MMP 8 Adapter 9C Puller Link 8A 9B Contactor 7 7A Spacer Fuse 9A 9 Fuse Block MMP & Contactor Detail SpeedTrol Fusing Detail F OR F Unit Size Ref. Sch. Part Part No. Sym Description Number Fan Contactor & Spacer 7 M- FanTrol Code 47=, SpeedTrol Code 47=, A Spacer MMP- MMP- Condenser Fan & Link FanTrol Code 47=, 3 08/30V Code 47=, Code 47= Code 47= SpeedTrol Code 47=, 4 08/30V Code 47= Code 47= Code 47= Code 47= A Link Units w/o Modulating Hot Gas Reheat Code 54= YY SpeedTrol Fusing Code 47= 9 FB, Fuse Block A F, F Fuse 08V 7A A A B Fuse Cover/Puller C DIN Rail Adapter SpeedTrol Fusing Code 47= 4 9 FB, Fuse Block A F, F Fuse.5A B Fuse Cover/Puller C DIN Rail Adapter Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 89

190 Section N- Main Control Box Power Panel: (03/03 & Earlier) Condenser Fan Contactors, MMPs, & Fusing, Continued Unit Size Ref. Sch. Part Part No. Sym. Description Number Units w/ Modulating Hot Gas Reheat Code 54= BM MHGR Fusing Code 47= 9 FB Fuse Block B Fuse Cover/Puller A F Fuse 08V 7A A A C DIN Rail Adapter MHGR Fusing Code 47= 9 FB, Fuse Block B Fuse Cover/Puller A F, Fuse 08V 7A A C DIN Rail Adapter Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 90

191 Section N- Main Control Box Power Panel: (03/03 & Earlier) Energy Recovery Wheel MMP60, 6 & Contactor M60, 6: Code 4= Y Diagram and Components MMP 8 Link 8A Contactor 7 7A Spacer Heat Recovery Control Type 00% OA Low Flow 00% OA HI Flow Economizer Code 0= E Code 0= E Code 0= 3E Ref. Sch. Part Part No. Sym. Description Number Heat Wheel Contactor 7 M60 Contactor M6 Contactor A Spacer Heat Wheel MMP 8 MMP60 Manual Motor Protector Manual Motor Protector MMP6 Manual Motor Protector Manual Motor Protector B Link- MMP /30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

192 Section N- Main Control Box Power Panel: (04/03 & Later) Diagram See Control Panel See Control Panel See Control Panel PL - PL43 Plugs The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 9

193 Section N- Main Control Box Power Panel: (04/03 & Later) Terminal Blocks, T Transformer, & Fuses Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB Terminal Block TB,3,4,7 Terminal Block Transformer- Main Control T Transformer Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Code 3= Y**** Unit Sizes 05-04D 000VA Unit Sizes 05-04D 000VA Unit Sizes 05-04D 000VA Units with UV Lights Code 3= U**** Unit Sizes D 500VA Unit Sizes D 500VA Unit Sizes D 500VA Unit Size 04D 000VA Unit Size 04D 000VA Unit Size 04D 000VA T Transformer Gas Heat Code 04= A Units without UV Lights Code 3= Y**** Unit Sizes 05-04D 500VA Unit Sizes 05-04D 500VA Unit Sizes 05-04D 500VA Units with UV Lights Code 3= U**** Unit Sizes D 500VA Unit Sizes D 500VA Unit Sizes D 500VA Unit Size 04D 000VA Unit Size 04D 000VA Unit Size 04D 000VA N/S Cover Kit, Terminal N/S Cover Kit, Fuseholder Fuses- T Transformer FUA, B Fuse- T Transformer, Primary 3 FUC Fuse- T Transformer, Secondary 3 N/S= Not shown on diagram. Varies depending on unit options. Part number is for one individual section. Ground block is p/n Jumpers are p/n (TBA:5), (TBB:4), (TBC:0, TBD:5 & TBE:30). Varies depending on unit options. Part number is for one individual section. Ground block is p/n Contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 93

194 Section N- Main Control Box Power Panel: (04/03 & Later) Fuses, Ground Fault Protection, Phase Protection (PVM, ), Power Supply, & Power Blocks Sch. Part Part Voltage Sym. Description Number 08V 30V Fuses F,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor Code 04= A F5 Fuse- UV Lights Code 7 (nd digit)= Ground Fault Code 7 [nd digit]= G, B, C, D, K GFR Ground Fault Relay- SPDT GFS Ground Fault Sensor Phase Voltage Code 7 [nd digit]= P, A, C, D, H, J, K PVM, Phase Voltage Monitor (/6 & Earlier) 000 Phase Voltage Monitor (/6 & Earlier) 000 Phase Voltage Monitor (/7 & Later) Phase Voltage Monitor (/7 & Later) Socket, PVM (/7 & Later) Power Blocks PB Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat , 60, 80, 00, 0, 40 KW Electric Heat PB0 Power Block- Supply Fan Code 5= F PB0 Power Block- Return Fan Code 5= F Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure that the correct part(s) are identified. For units built /7 check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure that the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 94

195 Section N- Main Control Box Power Panel: (04/03 & Later) Disconnect Switches & Plugs Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS Disconnect Switch- Main Switch- 00A Handle 9340 Shaft Switch- 50A Handle 9340 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Switch- 800A Handle Mechanism Shaft Lugs Switch- 000A Handle Mechanism Shaft Lugs Plugs 5 4 Pin Plug varies varies varies varies 6 6 Pin Plug varies varies varies varies 7 Pin Plug varies varies varies varies 8 3 Pin Cap Kit varies varies varies varies 9 6 Pin Cap Kit varies varies varies varies 0 9 Pin Cap Kit varies varies varies varies 5 Pin Cap Kit varies varies varies varies Disconnects are sized according to various unit specifications. Check the installed Switch to verify the DS size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. When a replacement switch is required for units with nonstandard SCCR ratings, contact Daikin Applied. This Shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This Shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. 5 Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 6 Used with Strain Relief (p/n ) & 6 pin Cap Kit (p/n ). Used for PL0, PL. 7 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 8 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 9 Used for PL9, PL0. 0 Used for PL8, PL9, PL35, PL36, PL43. Used for PL7, PL8. All possible Plugs used are listed. Check actual unit to verify which Plug is required. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 95

196 Section N- Main Control Box Power Panel: (04/03 & Later) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Diagrams Phase Barrier Front Mtd. Aux. Contact 3E MMP 3 Phase Barrier Front Mtd. Aux. Contact 3E MMP 3 MMP 3 Link 3B Contactor Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact 3B Link Contactor MMP0 & M0 Link Detail - HP Motors- All Voltages 3, 5 HP Motors- 460/ 7.5 HP Motors- MMP0 & M0 Link Detail 3, 5 HP Motors- 08/30V 7.5 HP Motors- 08/30/ 0 HP Motors- All Voltages 5, 0 HP Motors- MMP0 & M0 Link Detail 5 HP Motors- 08/30/ 0 HP Motors- 5 HP Motor- 460/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier 3E Front Mtd. Aux. Contact MMP 3 Link 3B Contactor MMP0 & M0 Link Detail 0, 5 HP Motors- 08/30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 96

197 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components HP Motor- Code OR 3= E*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 4A Fuse- Supply OR Return Fan A Fuse Cover/Puller- Supply OR Return Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V.5 HP Motor- Code OR 3= F*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 8A Fuse- Supply OR Return Fan 7A Fuse- Supply OR Return Fan 3A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 4 pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 97

198 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued HP Motor- Code OR 3= G*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 9A Fuse- Supply OR Return Fan 4A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V 3 HP Motor- Code OR 3= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 7A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 4 pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 98

199 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code OR 3= J*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 0A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V 7.5 HP Motor- Code OR 3= K*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 35A Fuse- Supply OR Return Fan 5A Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 4 pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 99

200 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code OR 3= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 50A Fuse- Supply OR Return Fan 45A Fuse- Supply OR Return Fan 0A Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 00

201 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code OR 3= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 0A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 70A Fuse- Supply OR Return Fan 60A Fuse- Supply OR Return Fan 30A Fuse Cover- Supply OR Return Fan Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

202 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code OR 3= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link Link E Phase Barrier Phase Barrier N/S VFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 70A Circuit Breaker- Supply OR Return Fan 60A Circuit Breaker- Supply OR Return Fan 30A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 40A Fuse Cover- Supply OR Return Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 08V 30V 5 HP Motor- Code 3= P*Y 3 Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply Fan 80A Contactor- Supply Fan 40A Contactor- Supply Fan 3A Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply Fan 57-75A MMP- Supply Fan 45-63A MMP- Supply Fan - 3A B Link Link Link E Phase Barrier N/S VFD0, 0 VFD- Supply Fan N/S CB0, 0 Circuit Breaker- Supply Fan 90A Circuit Breaker- Supply Fan 80A Circuit Breaker- Supply Fan 40A FB0, 0 Fuseblock- Supply Fan Fuse- Supply Fan 50A Fuse Cover- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 3 A 5HP Supply Fan Motor is only available when Code 3= 4**. A 5HP Motor is not available for Return Fan applications. 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

203 Section N- Main Control Box Power Panel: (04/03 & Later) Compressor MMP,, 4 and Contactor M,, 4 Diagrams Side Mtd. Aux. Contact (RPS) Front Mtd. Aux. Contact Link 3B 4 4 MMP 3 Contactor Front Mtd. Aux. Contact (RCS) Compressor Link Detail 00, 0 Cir #- Phase Barrier Front Mtd. Aux. Contact Link 3B 3E 3A Spacer Contactor Compressor Link Detail 05, 06 Cir #, - 08/460/ 00, 0 Cir #- 08/30/ 05, 06 Cir #- 05, 06 Cir #- All Voltages 030, 03 Cir #- 08/460/ 040, 04 Cir #, - Side Mtd. Aux. Contact (RPS) MMP 3 Front Mtd. Aux. Contact MMP 3B Link Front Mtd. Aux. Contact (RCS) Contactor Compressor Link Detail 05, 06 Cir #, - 30V 00, 0 Cir #- 08/30/ 05, 06 Cir #- 030, 03 Cir #- 460/ 030, 03 Cir #- 30V 040, 04 Cir #, - 08/30/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier Side Mtd. Aux. Contact (RPS) 4 3E MMP 3 5 Front Mtd. Aux. Contact Busbar Link 3B Contactor Front Mtd. Aux. Contact (RCS) Compressor Link Detail 05, 06 Cir #- 08/30V 030, 03 Cir #- 08/30V Feeder Terminal Feeder Terminal Compressor Link Detail ALL Sizes Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 03

204 Section N- Main Control Box Power Panel: (04/03 & Later) Compressor MMP, MMP and Contactor M, M Unit Sizes 05, 06 05, 06 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors M, Contactor- Circuit #, Contactor- Circuit #, Contactor- Circuit #, Contactor- Circuit #, Compressor MMP's & Parts Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP, Motor Protector- Circuit #, Motor Protector- Circuit #, Motor Protector- Circuit #, Motor Protector- Circuit #, A Spacer B Link Link E Phase Barrier Front Mtd. Aux. Contact- NO AND NC (RCS) Side Mtd. Aux. Interlock- NO OR NC (RPS) V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 04

205 Section N- Main Control Box Power Panel: (04/03 & Later) Compressor MMP,, 4 and Contactor M,, 4 Unit Sizes Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors Unit Size 00, 0 05, , 03 M Contactor 65A Contactor 40A Contactor 3A Contactor 5A Contactor 6A M, 4 Contactor 40A Contactor 3A Contactor 6A Contactor A Contactor 9A Comp. MMP's & Parts M Front Mtd. Aux. Contact Front Mtd. Aux. Contact M, 4 Front Mtd. Aux. Contact Front Mtd. Aux. Contact MMP Motor Protector 45-63A Motor Protector 36-45A Motor Protector 8-40A Motor Protector - 3A Motor Protector 8-5A Motor Protector 7- A Motor Protector 4-0A Motor Protector 4-0A Motor Protector - 6A Motor Protector 7-0A MMP, 4 Motor Protector 7-3A Motor Protector 3-8A Motor Protector - 3A Motor Protector 0-5A Motor Protector 4-0A Motor Protector 9-.5A Motor Protector 7-0A Motor Protector 5.5-8A V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 05

206 Section N- Main Control Box Power Panel: (04/03 & Later) Compressor MMP,, 4 and Contactor M,, 4 Unit Sizes 00-03, Continued Ref. Sch. Part Part No. Sym. Description Number 3A M Spacer M, 4 Spacer B M Link Link Link M, 4 Link Link Link E M Phase Barrier Phase Barrier M Side Mtd. Aux.- (RPS) Front Mtd. Aux.- (RCS) M, 4 Side Mtd. Aux.- (RPS) Side Mtd. Aux.- (RPS) Front Mtd. Aux.- (RCS) Front Mtd. Aux.- (RCS) M, 4 Busbar Busbar M, 4 Busbar Feeder Terminal Busbar Feeder Terminal V Unit Size 00, 0 05, , 03 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 06

207 Section N- Main Control Box Power Panel: (04/03 & Later) Compressor MMP thru 4 and Contactor M thru 4 Unit Sizes D Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors M- 4 Contactor 40A Contactor 5A Contactor 5A Comp. MMP's & Parts M- 4 Front Mtd. Aux. Contact Front Mtd. Aux. Contact MMP- 4 Motor Protector 8-40A Motor Protector 4-0A Motor Protector - 6A Motor Protector 7-0A A M- 4 Spacer B M- 4 Link Link M- 4 Side Mtd. Aux.- (RPS) Front Mtd. Aux.- (RCS) Busbar Busbar Busbar Feeder Terminal Busbar Feeder Terminal V Unit Size V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 07

208 Section N- Main Control Box Power Panel: (04/03 & Later) Condenser Fan Contactors, MMPs, & Fusing Phase Barrier 8A MMP 8 5 Adapter 9C Busbar Puller Link 7B 6 9B 7 Contactor Fuse 9A 9 Fuse Block MMP & Contactor Detail Feeder Terminal SpeedTrol Fusing Detail F OR F Unit Size Ref. Sch. Part Part No. Sym Description Number Contactor & Components 7 M- Contactor- FanTrol C47=, Contactor- SpeedTrol C47=, B Link- Contactor to MMP MMP- MMP & Components MMP- FanTrol Code 47=, 3 08V A V 3.5-5A A A MMP- SpeedTrol Code 47= 08V A A A MMP- SpeedTrol Code 47= 4 08V 3.5-5A A A Phase Barrier A Bus Bar, pos Bus Bar, Top Feed Units w/o Modulating Hot Gas Reheat Code 54= YY SpeedTrol Fusing Code 47= 9 FB, Fuse Block A F, Fuse 08V 5A A A B Fuse Cover/Puller C DIN Rail Adapter Quantity varies depending upon options selected. Confirm number required BEFORE ordering. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 08

209 Section N- Main Control Box Power Panel: (04/03 & Later) Condenser Fan Contactors, MMPs, & Fusing, Continued Unit Size Ref. Sch. Part Part No. Sym Description Number SpeedTrol Fusing Code 47= 4 9 FB, Fuse Block A F, Fuse 08V A A A B Fuse Cover/Puller C DIN Rail Adapter Units w/ Modulating Hot Gas Reheat Code 54= BM MHGR Fusing Code 47= 9 FB, Fuse Block A F, Fuse 08V 5A , 3.5A 6/3 & Earlier , 0A 7/3 & Later A B Fuse Cover/Puller C DIN Rail Adapter MHGR Fusing Code 47= 9 FB, Fuse Block A F, Fuse 08V 5A , 3.5A 6/3 & Earlier , 0A 7/3 & Later , 3A B Fuse Cover/Puller C DIN Rail Adapter Contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 09

210 Section N- Main Control Box Power Panel: (04/03 & Later) Energy Recovery Wheel Contactors, MMPs, & Fusing Phase Barrier 8E MMP 8 Fuse Block 9 Link 7B 7 Contactor Cover 9B 9A Fuse MMP & Contactor Detail ERW Fusing Detail Heat Recovery Control Type 00% OA Low Flow 00% OA HI Flow Economizer Code 0= E Code 0= E Code 0= 3E Ref. Sch. Part Part No. Sym. Description Number Heat Wheel Contactor 7 M60 Contactor 7A M6 Contactor 7A B Link- MMP Heat Wheel MMP 8 MMP60 Motor Protector Motor Protector Motor Protector Motor Protector MMP6 Motor Protector Motor Protector Motor Protector Motor Protector E Phase Barrier N/S Busbar N/S Busbar Feeder Terminal ERW Fusing 9 FB60,6 Fuse Block A F60, 6 Fuse 0A Fuse 9A Fuse 5A Fuse 4A Fuse 3A B Fuse Cover/Puller N/S CB60, 6 Circuit Breaker 5A N/S OL6 Overload 0.7- A N/S= Not shown on diagram. For Heat Wheel Inverter (VFD60) p/ns, refer to the "VFD60 Frost Protection Inverter (Code 4= F)" page in Section A. Fuse components for the Heat Wheel are located in the Power Panel. 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page 0

211 Section N- Main Control Box Intelligent Equipment: Code 3= ****A, ****L (Mid 0 & Later) Intelligent Equipment from Daikin Applied (Code 3= ****A) is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation. A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality IE Express (Code 3= ****L) connects directly to your Daikin unit and offers a low cost, easy to install, entrylevel solution to cloud equipment controls for those who don t need the Energy Management Module (EMM) found in the Intelligent Equipment offering. Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply. Click on this link to access the RPL for Intelligent Equipment: Rooftop Std. Cmpr. Units: RPS/RFS/RCS "D" Rev. AN 05/8 RPL / Page

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W Replacement Parts List No. 70005300 Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT 045-074 Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70003700 Revision U 07/2 Roofpak Applied Rooftop Units RPS, RDT, RFS, RCS Sizes 045-079 Tons Vintage D R40a To find your Daikin McQuay Parts distributor, call -800-377-2787 or

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019 Replacement Parts List No. 700052600 Revision G 0/209 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017 Replacement Parts List No. 110502600 Revision I 09/2017 McQuay Superpak Applied Rooftop Units RRS, RSS 018-071 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

RoofPak Applied Rooftop Systems Air Handler

RoofPak Applied Rooftop Systems Air Handler Installation and Maintenance Manual IM 987 RoofPak Applied Rooftop Systems Air Handler Group: Applied Air Systems Part Number: IM 987 Date: May 009 RAH 047C - 077C,,000 to 50,000 cfm RDS 800C - 80C, 4000

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018 Replacement Parts List No. 57113900 Revision AB 06/2018 McQuay Westinghouse Centrifugal Chiller PF, PFH 063 Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055223300 Revision B 06/2018 McQuay SeasonMaster Central Station Air Handler HSH, HMH, HWL 137-164 Vintage B 117-128 Vintage C Last Manufactured: 1984 To find your Daikin Applied

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information