1 Replacement Parts List No Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 5 Nomenclature Unit Model and Serial Number... 6 Unit Code Index Unit Layout Diagrams... 4, 5 Electrical Legend Section A- Outdoor/Return/Economizer Air Section Notes % Outside Air Damper with Hood AND No Return Air Plenum: Code 20= AE AND Code 9= YY... 2, % Outside Air Section Damper: Code 20= BE AND Code 9= BY, HY % Economizer w/ Barometric Exhaust Damper w/o RAF: Code 20= DE, EE, FE, GE, AND Code 2= YYYY % Economizer Section with Exhaust Damper Units with 5" Forward Curved Return Air Fans % Economizer Section with Exhaust Damper Units with 30" Air Foil Return Air Fans % Economizer Section with Exhaust Damper- Units with 40" Air Foil Return Air Fans % Economizer Assembly... 28, 29 California Title 24 Assembly: Code 33= *F*** Return Air Plenum Isolation Damper with Actuator ACT6... 3, 32 Design Flow Return Air Fan Mounting- 5" Forward Curved Fan Return Air Fan Mounting- 30" and 40" Airfoil Fan Rubber in Shear Components, Spring Mount Diagram Return Air Fan Mounting- 30" Spring and Seismic Mount Components: Code 2= 30B2, 30B Return Air Fan Mounting- 40" Spring and Seismic Mount Components: Code 2= 40B2, 40B Return Air Fan Deck- 5" Fans: Code 2= 5F, 5F2, 5F Return Air Fan Deck- 30" Fans: Code 2= 30B, 30B2, 30B Return Air Fan Deck- 40" Fans: Code 2= 40B, 40B2, 40B Return Air Fan Motors... 4, 42 Section Mounted Controls- SD2, LT, S, REC Section A2- Outdoor/Return Air w/ Heat Recovery Section Notes % Outside Air Low Flow: Code 20= E % Outside Air High Flow: Code 20= 2E Economizer: Code 20= 3E " Return Fan Detail- Fan Components " Return Fan Detail- Fan Mounts Low Leak Damper Detail- Outdoor/Return ACT3, Low Leak Bypass Damper Detail- Economizer ACT Heat Recovery/Enthalpy Wheel VFD60 Frost Protection Inverter: Code 24= F Section Mounted Controls- OAE, RAE, RAT, EAT, LAT Section Mounted Controls- SD2, HUM, LT, S, REC Section B- DrawThru Filter/Blank Section Notes Air Blender Section Mounted Controls- PC Filters, Filter Section Components Magnehelic Differential Pressure Gauge Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes Section Mounted Controls- LT2, REC2, S Section D- DrawThru Cooling Section Notes Evaporator Coil Drain Pans and Gaskets- Unit Sizes 035, 042D Evaporator Coils- Unit Sizes 035, 042D... 6 Section E- DrawThru Blank Access Section Notes Section Mounted Controls- LT8, REC8, S Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 2

3 Contents, Continued Section F- Supply Air Section Notes DrawThru Evaporator Coil Drain Pans- Unit Sizes 06-03D Evaporator Coils- Unit Sizes 06-03D Fan Assembly 5" X 6" and 5" X 5" Forward Curved Fans- Unit Sizes 06-03D Fan Assembly 20" Airfoil Fans- Unit Sizes 06-03D Fan Assembly- 24" Airfoil Fans - Unit Sizes 035, 042D Supply Air Fan Mounting- 5" X 6": Code 3= 06F, 06F2, 06F Supply Air Fan Mounting- 5" X 5": Code 3= 5F, 5F2, 5F Supply Air Fan Mounting- 20" Airfoil Fan: Code 3= 20A, 20A2, 20A Supply Air Fan Mounting- 24" Airfoil Fan: Code 3= 24A, 24A2, 24A Supply Fan Motors... 73, 74 Inverter & Inverter Bypass Control Box- Motor HP , 76 Inverter & Inverter Bypass Control Box- Motor HP Inverters (VFD/AFDs) Section Mounted Controls- PC7, EFT, HL22, LT0, S0, REC0, UV Lights Section G- BlowThru Heat Section Notes Option - Blank/Empty Section: Code 04= Y Diffusers Option 2- Hot Water OR Steam Heating Coil: Code 04= W, S Coils and Coil Compartment Components Valves: Code 04= W, S AND Code 34= W****E, S****E Option 3- Electric Heat: Code 04= E Diffusers, High Limit HL4, HL4 & HL Electric Heating Assemblies and Elements Electric Heat Control Box- MicroTech III Option 4- Gas Heat: Code 04= A Heat Exchangers and Vestibules- 200, 250 MBH Furnaces Heat Exchangers and Vestibules- 320, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces Modulating Burner- Burner Box, Pilot Valve, Pressure Regulator Diagram Modulating Burner- Components... 97, 98 Hi Turn Down Burner- Diagram Hi Turn Down Burner- Components Modulating Burner Controls- MicroTech III: Code 2= *E, *F, *W Hi Turn Down Burner Controls- MicroTech III: Code 2= *E, *F, *W Gas Train Inlet- Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train Inlet- Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train Controls- Modulating Burner: Code 34= ****E*, ****R*, ****S* (GV2, GV3) Gas Train Controls- Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* (GV, GV2, GV4, GV5, GV6) Gas Train Outlet Gas Train Damper Linkage- Modulating Burners / VM Actuator: Code 34= ****E*, ****R*, ****S*... 0 Cabinet Doors, Gasketing, Hardware & Flue Box Mounting: Code 34= 020***, 025***... Cabinet Doors, Gasketing, Hardware & Flue Box Mounting: Code 34= 032*** thru 00***... 2 Section H- BlowThru Heat Blank Access Section Notes... 3 Access Door Latching Assemblies, Key, & Lock (All Sections)... 3 Section I- BlowThru Cooling Section Notes... 4 BlowThru Evaporator Coil Drain Pans and Gaskets- Unit Sizes 035, 042D... 5 Evaporator Coils- Unit Sizes 035, 042D... 6 Section J- Final Filter Section Notes... 7 Section Mounted Controls- HL23, PC6, SPS Filter Frame, Filter Gaskets, Filters... 8 Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 3

4 Contents, Continued Section K- Discharge Plenum Section Notes... 9 Section Mounted Controls- OAT, DAT, SD... 9 Damper Assembly- w/ Actuator ACT Section L- Out-of-Airstream Blank Access Section Notes... 2 Section M- Condenser Section Notes Fan Deck Diagrams Standard Condenser Fan- Fan Motor, Motor Mount, Fan Deck Panel: Code 47= Quiet Fan Assembly: Code 47= Compressors Circuit # Compressors Circuit #2, Compressor Crankcase Heaters Inverter Compressor Components Compressor Mounting Condenser Coils & Coil Guards... 30, 3 Pressure Controls Box Factory Supplied Powered Receptacle DS6, TB7, T6, FU6A, B, C: Code 23= ***F* Inverter Compressor Control Box Section N- Main Control Box Notes Control Box Component Label Diagram Control Panel... MicroTech III Units with Controller: Code 2= *E, *F, *W- Diagram MicroTech III Units with Controller: Code 2= *E, *F, *W- Components... 38, 39 Power Panel Power Panel Diagram Terminal Blocks, T Transformer, Fuses... 4 Fuses, Ground Fault Protection, Phase Protection (PVM, 2), Power Supply, Power Blocks Disconnect Switches, Plugs Supply MMP0 & M0 Fan Contactor, Return MMP20 & M20 Fan Contactor Diagrams Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components Compressor Motor Protector MMP, 3, Contactor M, 3 & Fusing Compressor Motor Protector MMP, 3, Contactor M, 3 Diagrams... 5 Unit Size 06D Unit Sizes D Unit Sizes 035, 042D SpeedTrol Condenser Fan Fusing: Code 47= 2, Energy Recovery Wheel Contactors, MMPs, & Fusing Intelligent Equipment Section O- Refrigeration Tubing Notes Refrigeration Piping Schematic Refrigeration Tubing Diagrams Valves, Filter Driers, Sight Glasses, & Hot Gas Bypass... 60, 6. Hot Gas Reheat Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 4

5 Parts List Revision History Rev. Date Description New 2/5 New. Used form # Rev. AF as a template. A 0/6 Page 58 (NEW): Added pg. for IE info & hyperlink. Repaginated form & updated the TOC. Page 62 (OLD) 63 (NEW). Added footnote #2 & footnote notation. B 03/6 Page 20, 22: Rewrote Notes. Page 33: Added "JE" to pg. header. Page 63, 22: Rewrote Notes. Page 84: Changed Lamp to Bulb or Fixture. Page 04: Updated Ref #34 TB p/ns. Page 6: Added missing footnote. Page 7: Corrected Section Mounted Controls header coding. Page 33: Changed pg. header from "Pressure Controls" to "Pressure Control Box". Updated the TOC. Page 35: Added Local Ctrl. Panel p/n & dwg. Rewrote footnotes. Added TB4 detail dwg. header. Page 36, 37: Pages were reversed in order. TOC okay. Updated dwg. on pg. 37. Page 39: Corrected SPS, 2 p/n from " " to " ". Page 52: Rewrote pg. header to match TOC entry. Page 56: Added footnote #2 & footnote notation. Rewrote pg. header & updated the TOC. Page 64: Deleted pg. Option not offered yet. Repaginated the form & updated the TOC. C 06/6 Page 22: Rewrote Notes. Page 23: Updated the Fan Deck dwgs. Moved Coil guard dwgs. from 29, 30 (OLD) to 30, 3 (NEW). Updated the TOC. Page 24: Deleted pg. Added footnote # 2. Repaginated the form & updated the TOC. Page 27: Added compressors. Deleted footnote #. Page 35: Added footnote # 2. Page 30 (OLD) 3 (NEW): Updated Coil Guard p/ns. Page 39 (OLD) 38 (NEW): Added MTIII Remote Keypad & Remote Interface p/ns. Page 40 (OLD) 39 (NEW): Moved Remote Interface p/n to Pg. 39. Page 58 (OLD) 57 (NEW): Rewrote notes for IE. Added coding to pg. header. D 06/6 Page 9: Added TB35-37 info. Page 32: Added new TB37 p/n for units. Rewrote footnotes & updated TB36, 37 descriptions. E 05/7 Page 2: Misc. corrections. Page 7: Rewrote footnote #. Page 29: Corrected Ref # 22 description & p/n. Page 4: Corrected coding. Page 44, 22: Rewrote Notes. Page 52: Corrected Ref. # 6 Motor p/ns. Page 55: Updated HUM p/ns. Page 03, 04: Added footnote # & footnote notation. Corrected Ref # 34 TB p/n qtys. Page 3: Updated Latching Assy. descriptions. Rewrote footnote # 2. Page 39: Updated/corrected R63 p/ns. Page 55: Updated/corrected Ref. # 9A Fuse p/ns & qtys. Page 60, 6: Updated HGBP p/ns and rewrote footnotes & footnote notation. Rewrote pg. header/updated TOC. F 08/7 Page 60, 6: Added Check Vlv. p/s. Page 62: Updated Ref #s 200, 233. Deleted footnote # 2. G 09/7 Page 8: Deleted "PVM4". (RCS only) Page 42: Added /7 & Later PVM components. Rewrote the pg. header & updated the TOC. Corrected qtys. H 0/7 Page 28: Added Sight Glass/Prism p/n, Bub., & footnote #. I 02/8 Page 89: Rewrote dwg. headers. Page 2: Updated dwg. Page 27: Corrected CC Heater p/ns. Page 38: Deleted OBS Display. Combined with Remote Keypad Page 39: Deleted duplicate entry for OBS Display. Page 57: Fixed misc. formatting issues. J 05/8 Page 9, 3: Misc. updates. Page 42: Corrected Code 7 coding. Page 57: Rewrote Notes & pg. header. Updated the dwg. Page 60-62: Updated tables, rewrote footnotes. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 5

6 Nomenclature Unit Model and Serial Number Unit Model Number R P S 06 D A Singlezone Unit Unit Configuration P= Heating, mechanical cooling Roofpak: R= Roofpak Applied Rooftop Design Vintage Nominal Capacity (Tons) Ex. 06= 6 Tons Heating Medium A= Natural Gas E= Electric S= Steam W= Hot Water Y= None (cooling only) Serial Number Plant Identification Abbreviation FBO = Faribault, MN U= Unit Year of Manufacture 4= 204, 5= 205, 6= 206, 7= 207, etc. FBO U Month of Manufacture 0= Jan. 04= Apr. 02= Feb. 05= May 03= Mar. 06= Jun. Serial Number (build sequence) 07= July 08= Aug. 09= Sept. 0= Oct. = Nov. 2= Dec. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 6

7 Nomenclature Unit Code Index RPS 06D S W Y EU D 27 AL P LE 2 A 3 CD A20 BB E 24B2 GEY Code YYAYA F AB Y CYYS 4Z083D YYYYYY YYYYYY 20A2 LEY YYYYY WD3E YYYY YYYYYY YYYYYY Y Y BY Y M MB V 2 Y D Y YYYYYY YY YY BM HE YY YY 250A 250A XX A A A 027C L Y YY YYYYYYYY General Options Unit Model Codes that Pertain: 03, 05, 06, 07, , 25, 33, 6-72 Auxiliary Controls/Remote Sensors Unit Model Codes that Pertain: 2, 3, 6, 7, 8, 33 Sections A, A2 Return/Outside Air/Heat Recovery Options Unit Model Codes that Pertain: 9, 20, 2, 22, 24, 58 Sections B, C, D, E DrawThru Cooling Sections Section B- Filter Unit Model Codes that Pertain: 25, 33, 50 Section C- DrawThru Blank Access Unit Model Codes that Pertain: 4, 5, 26 Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 27, 28 Section E- DrawThru Blank Access Unit Model Codes that Pertain: 30 Section F- Supply Fan Options Unit Model Codes that Pertain: 4, 5, 3, 32, 49, 59 (all unit sizes); 27, 28 (06-03D only) Sections G, H, I BlowThru Options Section G= BlowThru Heat/Blank Unit Model Codes that Pertain: 04, 34 Section H= BlowThru Blank Access Unit Model Codes that Pertain: 38 Section I- BlowThru Cooling Sections Unit Model Codes that Pertain: 35, 36 Section J- Final Filter Section Unit Model Codes that Pertain: 33, 39 Section K- Discharge Plenum Section Unit Model Codes that Pertain: 40 Section L- Out-of-Airstream Blank Access Section Unit Model Codes that Pertain: 4 Section M- Condenser Section Unit Model Codes that Pertain: 09, 43, 44, 45, 47 Section N- Main Control Panel Unit Model Codes that Pertain: 09,, 2, 3, 4, 5, 6, 7, 8, 68 Section O- Refrigeration Tubing Unit Model Codes that Pertain: 45, 46, 54 An "X" located in Code 60 in a code string indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas with the EXCEPTION of special text that ONLY indicates the presence of variable speed scroll compressors. So, in cases where sections of the unit have special features (not strictly related to the presence of inverter compressors), it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 7

8 Nomenclature Unit Code Index, Continued Code 03= Cooling Coil Size S= Small face area coil L= Large face area coil Code 04= Heat Section- Type of Heat Y= No Heat A= Natural Gas Heat E= Electric Heat S= Steam Heat W= Hot Water Heat Code 05= Split Unit Y= None C= Split at Unit/Condenser Sections F= Split at Fan/Heat Sections Code 06= Insulation and Liners = ", 3/4# with Liners on Doors 2= ½",.5# with Solid Liners on Doors & Ceilings 3= ½",.5# with Perforated Liners in Plenums, solid elsewhere 4= ½",.5# with Solid Liners on Doors, Ceilings and Floors 5= ½",.5# with Perforated Liners in Plenums, solid elsewhere (including Floor) 6= ½",.5# with Stainless Steel Solid Liners on Doors, Ceilings and Floors Code 07= Approval Agency Listing Digit Y= None E= ETL/MEA- USA C= ETL- Canada Digit 2 Y= None U= ETL M= ETL w/ Massachusetts Code C= ETL Canada with Low Altitude Burner (less than 2000 feet) D= ETL Canada with High Altitude Burner (over 2000 feet) Code 08= Main Control Box Location D= Standard (Discharge Plenum) Code 09= Unit Voltage 2= 208/60/3 29= 230/60/3 27= 460/60/3 37= 575/60/3 Code 0= Starting Option AL= Across-the-Line Code 2= Temperature Control Package MicroTech III Digit : Communication Type L= LonWorks B= BACNet w/mstp E= BACNet w/ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit 2: Control Type E= Discharge Air w/ Static Pressure Control F= Space or Zone Ctl. W= Discharge Air w/ Space Control Code 3= Air Flow Controls Y= None = Duct Sensor 2= 2 Duct Sensors 3= Duct & Space Sensor 4= Space Sensor 5= Duct High Limit Sensor Code 4= Inverters Y= None Separate Section = SA Fan only w/ Bypass 2= SA & RA Fans w/ Bypass 4= RA Fan only w/ Bypass No Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan w/o Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan w/o Bypass Code 5= Inverter Vendor Y= None A= ABB Inverter B, S= Daikin Applied Inverter G= Graham Inverter Q= Schneider Inverter R= Reliance Inverter F= Field Installed Inverter, MicroTech III controlled Code 6= Smoke Detectors Y= None = Return Air Only 2= Supply Air Only 3= Supply and Return Air Code = Field Power Connection and Disconnect Digit : Type of Control P= One Power Block - Complete unit A= One Disconnect - Complete unit C= Two Disconnects - Fans/Controls/Unit R= Two Power Blocks - Elect. Heat/Unit Digit 2: Disconnect Mechanism Location = Internal 2= Through the door Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 8

9 Nomenclature Unit Code Index, Continued Code 7= Misc. Auxiliary Controls Digit : Control Type Y= None, includes Mechanical Enthalpy when Code 20= DE, EE, FE, GE, 3E C= Differential Enthalpy (Code 20= DE, EE, FE, GE, 3E) Digit 2: Control Type Y= None F= Freezestat (Steam or HW Heat only) P= Phase Failure G= Ground Fault Protection L= Line Reactors (Inverter w/ separate section only) A= Freezestat & Phase Failure (Steam, HW Heat only) B= Freezestat & Ground Fault (Steam, HW Heat only) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam or HW Heat only) E= Freezestat & Line Reactors (Steam or HW Heat & Inverter w/separate sect. only) H= Phase Failure & Line Reactors (Inverter w/ separate section only) J= Freezestat, Phase Failure & Line Reactors (ST, HW Heat & Inverter w/separate sect. only) K= Ground Fault, Phase Failure & Line Reactors (ST, HW Heat & Inverter w/separate sect. only) Code 8= Misc. Controls/Unit Length A, S, Y = None ( = Air Handler Length [in.]) R = Remote Keypad ( = Air Handler Length [in.]) Code 9= Return Air Plenum YY= No section BY= Bottom Return BB= Bottom Return w/ Burglar Bars BE= Bottom Return w/ Isolation Damper HY= Back Return LY= Left Side Return RY= Right Side Return Code 20= Outdoor Air Options YY= None AE= 00% Outside air damper w/hood & Actuator BE= 0-30% Outdoor air section w/actuator DE= 0-00% Econ. w/barometric exhaust damper w/ Act. EE= 0-00% Econ. w/power closure exhaust damper w/ Act. FE= same as DE + Design Flow GE= same as EE + Design Flow E= Heat Recovery 00% OA Low Flow w/ Actuator 2E= Heat Recovery 00% OA High Flow w/ Actuator 3E= Heat Recovery Economizer w/ Actuator Code 2= Return Air Fan Digits - 3: Fan Size & Wheel Type 5F= 5" X 5" Forward Curved 24B= 24" Airfoil (Heat Recovery units only) 30B= 30" Airfoil 40B= 40" Airfoil Digit 4: Fan Isolation type = Rubber-in-shear (RIS) 2= Spring 3= Spring w/seismic Snubbers Code 22= Return Air Fan Motor YYY= No Return Fan E E Y Y= None S= W/ Shaft Grounding Kit E= High Eff. ODP motor H= High Eff. Totally-Enclosed motor J= Premium Eff. ODP motor K= Premium Eff. Totally-Enclosed motor E=.0 HP F=.5 HP G= 2.0 HP H= 3.0 HP J= 5.0 HP K= 7.5 HP L= 0.0 HP M= 5.0 HP N= 20.0 HP Code 23= Miscellaneous Electrical Options Digit : UV Lights Y= None U= UV Lights Digit 2: Plenum/Vestibule Lights Y= None P= Plenum Lights V= Vestibule Lights B= Plenum & Vestibule Lights Digit 3: SpeedTrol, Energy Recovery, HGRH Inverter(s) Y= None A= ABB B= Daikin Applied Q= Schneider Digit 4: 5V Service Outlet Y= None F= Factory supplied Line Voltage Outlet Digit 5: Intelligent Equipment Y= None A= Intelligent Equipment (IE) L= ie Express Code 24= Heat Wheel Frost Protection Y= None F= Frost Protection Inverter (VFD/AFD60) Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 9

10 Nomenclature Unit Code Index, Continued Code 25= DrawThru Filter Section Digit : Section Type A= Angular (22" Section) F= Flat (22/28" Section) B= Blank 22" section C= Blank 28" section Digit 2: Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/intersept H= Throwaway 85% Efficient D= Cartridge 65% Efficient w/ 2" Prefilters E= Cartridge 95% Efficient w/ 2" Prefilters G= Cartridge 65% Efficient w/ 2" Prefilters & Intersept Code 26= Blank DrawThru Section Y= No section A= Blank 22" Section C= Blank 40" Section D= Blank 52" Section Code 27= DrawThru Coil Section/Drain Pan Digits - 3: Cooling Type YYY= No section CYY= Cooling unit DYY= Drain Pan only (40" section) GYY= Cooling w/ Hot Gas Reheat (40" section) Digit 4: Options S= Std. stainless steel Drain Pan P= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY only) Code 28= Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) 3= 3 Row 4= 4 Row 5= 5 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch 2= 2 Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 29= N/A to RPS- Always YYYYYY Code 30= DrawThru Blank Access/Spacer Section YYYYYY= No section AAAAAA= 22" Blank Access/Spacer section CCCCC= 40" Blank Access/Spacer section Code 3= Supply Air Fan Digits - 3: Fan Size & Wheel Type 06F= 5" X 6" Forward Curved 5F= 5" X 5" Forward Curved 20A= 20" Airfoil 24A= 24" Airfoil Digit 4: Fan Isolation type = Rubber-in-shear (RIS) 2= Spring 3= Spring w/seismic Snubbers Code 32= Supply Air Fan Motor E E Y Y= None S= W/ Shaft Grounding Kit E= High Eff. ODP motor H= High Eff. Totally Enclosed motor J= Premium Eff. ODP motor K= Premium Eff. Totally Enclosed motor E=.0 HP K= 7.5 HP F=.5 HP L= 0.0 HP G= 2.0 HP M= 5.0 HP H= 3.0 HP N= 20.0 HP J= 5.0 HP P= 25.0 HP Code 33= Miscellaneous Mechanical Options Digit : Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DrawThru & Blow- Thru sections Digit 2: California Title 24 Y= None F= Economizer with Fault Detection/Diagnosis (FDD) Digit 3: Ebtron Air Flow Measuring Y= None S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold) Digit 4: Heating Coil Options Y= None E= Electrofin Coating Digit 5: Cooling Coil Options Y= None E= Electrofin Coating Code 34= Blow Thru Heat Section YYYYYY= No section (cooling unit only) BBBBBB= Blank 40" section Gas Heat Breakdown: 020 S H A A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position E= Modulating Burner (3:) R= Modulating Burner/with H.P. Regulator Range= 2-3 psi S= Modulating Burner/with H.P. Regulator Range= 5-0 psi H= Hi Turn Down Burner (20:) T= Hi Turn Down Burner with H.P. Reg. Range= 2-3 psi U= Hi Turn Down Burner with H.P. Reg. Range= 5-0 psi S= Stainless Steel Heat Exchanger MBH (in 0's) ex. 020= 200 MBH [020,025,032,040,050,064,065,079,080,00] Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 0

11 Nomenclature Unit Code Index, Continued Code 34= Blow Thru Heat Section, Continued Electric Heat Breakdown: E 020 Y Always Y = Stage 2= 2 Stage 3= 3 Stage KW (ex. 020= 20 KW) [020,040,060,080,00,20,40,60, 80] E= Electric Heat Hot Water OR Steam Heat Breakdown: W D 3 E E= Electric Actuator 2= 2- Way Valve (ST) 3= 3- Way Valve (HW) D=.00" Valve E=.25" Valve F=.50" Valve G= 2.00" Valve = 9 FPI Row (HW) or 6 FPI Row (ST) 2= 2 FPI Row (ST) 22= 9 FPI 2 Row (HW) W= Hot Water Heat (HW) S= Steam Heat (ST) Code 35= BlowThru Coil Section/Drain Pan Digits - 3: Cooling Type YYY= No section CYY= Cooling unit DYY= Drain Pan only (40" section) GYY= Cooling w/ Hot Gas Reheat (40" section) Digit 4: Options S= Std. stainless steel Drain Pan P= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY only) Code 36= Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) 3= 3 Row 4= 4 Row 5= 5 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch 2= 2 Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 37= N/A to RPS- Always YYYYYY Code 38= Attenuator Section Y= No section G= With 36" Std Straight Attenuator K= With 36" Std Straight Attenuator w/ Tedlar Coating H= With 60" Std Straight Attenuator L= With 60" Std Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating A= Blank 22" Section C= Blank 40" Section D= Blank 52" Section Code 39= Final Filter Section Y= No section A= Flat filter section, 95% cartridge, 28" section B= Flat filter section, 95% cartridge, 52" section C= Blank- 28" section D= Blank- 52" section E= Flat filter section, 95% cartridge, 28" section with Intersept F= Flat filter section, 95% cartridge, 52" section with Intersept G= Flat filter section, 95% HEPA cartridge, 28" section H= Flat filter section, 95% cartridge, 52" section Code 40= Discharge Air Plenum Digit B= Bottom L= LH side (opposite drive side) R= RH side (drive side) Digit 2 Y= None B= Burglar Bars E= Isolation Damper w/actuator Code 4= Blank/Empty Section Y= No section 2= 40" Section Out Of Airstream Code 42= Compressor Capacity Control M= Modulating Code 43= Condenser Options Digit : Air Coils M= 25mm Microchannel Coil P= 25mm Microchannel Electrofin coated Coil T= 32mm Microchannel coil U= 32mm Microchannel Electrofin coated Coil Digit 2: Miscellaneous Options G= Coil/Vandal Guards (coated steel) S= Sealtite Conduits B= Coil/Vandal Guards & Sealtite Conduits Y= None Code 44= Compressor Type V= Variable Speed Scroll W= Variable Speed Scroll w/ Line Reactor Code 45= Compressor Isolation = Resilient rubber-in-shear Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page

12 Nomenclature Unit Code Index, Continued Code 46= Piping Options Y= None = Hot Gas Bypass, Circuit # 2= Hot Gas Bypass, Circuit # & #2 3= Replaceable Core Filter Drier 4= Hot Gas Bypass Circuit # w/replaceable Filter Drier Core 5= Hot Gas Bypass Circuit # & 2 w/replaceable Filter Drier Cores Code 47= Low Ambient Operation 2= SpeedTrol (includes FanTrol) 4= Quiet Fan + SpeedTrol L= Low Ambient Code 48= IBC Seismic Const./ASCE 7-0 Wind Certification Y= None A= ASCE 7-0 Wind Certification & IBC Seismic Construction I= IBC Seismic Construction J= IBC Seismic Construction- Category E/F Code 49= Supply and Return Fan Options Y= None A= SA Fan Belt Guard B= SA Fan Section Light C= SA Fan Belt Guard w/ SA Fan Section Light D= SA & RA Fan Belt Guard E= SA & RA Fan Section Light F= SA & RA Fan Belt Guard w/ SA & RA Fan Section Light Code 50= Blender Section Y= None L= Low CFM Blender, 52 Inch Section H= High CFM Blender, 52 Inch Section A= Blank 22" Section C= Blank 40" Section D= Blank 52" Section Code 5= DrawThru Pre-Heat Section YYYYY= None AAAAAA= Blank 22" Section CCCCCC= Blank 40" Section DDDDDD= Blank 52" Section W D 3 E Y= No Actuator E= Electric Actuator Y= No Valve 2= 2- Way Valve (ST) 3= 3- Way Valve (HW) Y= No Valve D=.00" Valve E=.25" Valve F=.50" Valve G= 2.00" Valve = 9 FPI Row (HW) OR 6 FPI Row (ST) 2= 2 FPI Row (ST) 3= 06 FPI 2 Row (ST) 4= 2 FPI 2 Row (ST) 22= 9 FPI 2 Row (HW) W= Hot Water Heat (HW) S= Steam Heat (ST) Code 52= Drain Pan/Humidifier Section YY= None AA= Blank 22" Section CC= Blank 40" Section DD= Blank 52" Section DH= Humidifier w/stainless steel Drain Pan 40" section DY= Stainless steel Drain Pan only, 48" section Code 53= Custom Specifications YY= None RR= "B" vintage replacement unit Code 54= Hot Gas/Liquid Subcool Reheat YY= None BM= BlowThru Modulating Hot Gas Reheat Cir. #2 (includes SpeedTrol) ML= Modulating Liquid Subcool Reheat Circuits # & 2 (includes SpeedTrol) BL= BlowThru Modulating Hot Gas Circuit #2, AND Modulating Liquid Subcool Reheat Circuits # & 2 (includes SpeedTrol) Code 55= Ultra High Efficiency Units YY= None HE= Ultra High Efficiency Unit (06D, 02D, 026D, 03D) Code 56= Chicago Code/Refrigeration Service Valves YY= None CC= Chicago Code YV= Refrigeration Service Valves CV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS- Always YY Code 58= Return Air Fan Drive Selection A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 59= Supply Air Fan Drive Selection A Service Factor/Pitch Type A= Std. SF/Fixed Pitch Required RPM B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 60= Miscellaneous Specials YY= None XX= Special Code 6= Packaging = Steel Skid 2= Consolidated Ship Code 62= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 2

13 Nomenclature Unit Code Index, Continued Code 63= Compressor Warranty A= Standard One Year Compressor Q= Extended Four Year Compressor, Five Year Total Z= Special Code 64= Heat Exchanger Warranty Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 65= Unit Family 027C= 06D- 03D 037C= 035, 042D Code 66= Drain Connection Y= None L= Left Side (opposite drive side) R= Right Side (drive side) Code 67= ASHRAE Certification Y= None B= AHRI Certified C= AHRI Certified D= AHRI Certified Code 68= Short Circuit Current Rating YY= None 0= 0 SCCR 22= 22 SCCR 65= 65 SCCR Code 69= Labor Warranty Digit : Unit Labor A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Y= None Z= Special Digit 2: Compressor Labor A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Y= None Z= Special Codes N/A to RPS- Always YYYYYYYY Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 3

14 Unit Layout Diagrams Unit Section Layout.5" NPT Drain The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 4

15 Unit Layout Diagrams Control & Sensor Locations Compressor VFD Condensor section OOE SV SC, 2 (optional) C, 2 (optional) SV9, SV0 Filter section Supply fan section FS (optional) Heat section Discharge plenum section DX section HTR-2, HTR3-4 (optional) Return air economizer SD2 (optional) C9 RAT LT (optional) S, REC OAE OAT PC7 EFT HL22 (optional) LT0 (optional) S0, R EC0 (optional) ACT3 PC5 ACT6 (optional) RAE (optional) DAT ACT5 (optional) VM (optional) SD (optional) OOE SV Compressor Control Box The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 5

16 Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT0, Actuator Motors, Exhaust Dampers Return Air Section ACT2, 3 Actuator Motors, Enthalpy Wheel Bypass Damper Energy Recovery Section AS Airflow Switch, Burner Blower Gas Heat Box BM Burner Blower Motor Furnace Section C- C4 Power Factor Capacitors, Compressors Condenser Section C0 Power Factor Capacitor, Supply Fan Supply Air Section C Capacitor, SpeedTrol Circuit # Cond. Bulkhead C20 Power Factor Capacitor, Return Fan Return Air Section C2 Capacitor, SpeedTrol Circuit #2 Cond. Bulkhead CB0 Circuit Breaker, Supply Fan Main Control Box CB20 Circuit Breaker, Return/Exhaust Fan Main Control Box CB60 Circuit Breaker, Energy Recovery Wheel Main Control Box CDS2 Discharge Thermostat VFD Compressor COMPR.- 4 Compressors Condenser Section CS, 2 Control Switches, Refrigeration Circuits Main Control Box DAT Discharge Air Temperature Sensor Discharge section DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS Disconnect, Total Unit or Condenser/Heat Main Control Box DS2 Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS6 Disconnect, Factory Powered Outlet Condenser Section EAT Exhaust Air Temperature Sensor Energy Recovery Section EFT Entering Fan Air Temperature Sensor Supply Fan Section ERM, 2 Energy Recovery Wheel Motors Energy Recovery Section EXPA- D MicroTech III Expansion Boards Main Control Box FA, B Fuses, Control Circuit Transformer, (T) Primary Main Control Box FC Fuse, Control Circuit Transformer, (T) Secondary Main Control Box F2 Fuse, Control Circuit Transformer, (T2) Primary Main Control Box F3 Fuse, Burner Blower Motor Main Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section FB2M Fuseblock, Inverter Compressor Main Control Box FB0 Fuseblock, Supply Air Fan Main Control Box FB, 2, 2, 22 Fuseblocks, SpeedTrol Main Control Box FB20 Fuseblock, Return Air Fan Main Control Box FB3-40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Box FB4-50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Box FB60 Fuseblock, Energy Recovery Wheel Main Control Box FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FP, 2 Frost Protection, Refrigeration Circuits Coil Section, Cool FS, 2 Freezestat Control Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Box GFR, 2 Ground Fault Relays Main Control Box GFS, 2 Ground Fault Sensors Main Control Box GFR4 Ground Fault Relay, Condenser Condenser Control Box Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 6

17 Electrical Legend Continued Schematic Sym. Description Location GFS4 Ground Fault Sensor, Condenser Condenser Control Box GRD Ground All Control Boxes GV Gas Valve, Pilot Furnace Section GV2 Gas Valve, Main/Safety Furnace Section GV3 Gas Valve, Redundant/Safety Furnace Section GV4-8 Gas Valve, Main, Hi-Turn Down Furnace Section HL- 0 High Limits, Power, Electric Heaters (Top Bank) Electric Heat Section HL- 20 High Limits, Power, Electric Heaters (Bottom Bank) Electric Heat Section HL22 High Limit, Gas Heat (Prefilters) Supply Air Section HL23 High Limit, Gas Heat (Final Filters) Final Filter Section HL3-40 High Limits, Control, Electric Heaters (Top Bank) Electric Heat Section HL4-50 High Limits, Control, Electric Heaters (Bottom Bank) Electric Heat Section HP- 4 High Pressure Controls, Refrigerant Compr./Press./Cond. Box HP5 High Pressure Control, Gas Furnace Section HS Heat Switch, Electric Shutdown Main Control Box HS3 Heat Switch, Electric Heat Deadfront Interlock Electric Heat Box HTR- 4 Crankcase Heaters On Compressors HUM Humidistat Sensor Energy Recovery Section IT Ignition Transformer Furnace Section LAT Temperature Sensor, Leaving Air Energy Recovery Section LP- 4 Low Pressure Controls, Refrigerant On Compr./Cond. Box LP5 Low Pressure Control, Gas Furnace Section LR0 Line Reactor, Supply Fan Inverter Bypass Box LR20 Line Reactor, Return/Exhaust Fan Inverter Bypass Box LR, 2 Line Reactors, Condenser Fan SpeedTrol Pressure Control Box LS, 2 Limit Switches, Low/High Fire Furnace Section LT0 Light, Supply Fan Supply Air Section LT Light, Return Fan Return Air Section LT2 Light, Heat Section Heat Section LT3 Light, Filter Section Filter Section LT4 Light, Final Filter Section Final Filter Section LT5 Light, Discharge Section Discharge Section LT6 Light, Blow-through Coil Section BlowThru Coil Section LT7 Light, Evaporator Coil Section Evaporator Coil Section LT8 Light, Preheat Section Preheat Section LT9 Light, Blank Section Blank Section LT20 Light, Blank/Empty Section Blank/Empty Section LT2 Light, Draw Thru Coil Section DrawThru Coil Section LT22 Light, Condenser Section Condenser Section M, 3 Contactors, Compressors Main Control Box M0 Contactor, Supply Fan Main Control Box M- 8 Contactors, Condenser Fans, Circuit # Main Control Box M20 Contactor, Return Fan Main Control Box M2-28 Contactors, Condenser Fans, Circuit #2 Main Control Box M29 Contactor, Burner Motor Furnace Section M30 Contactor Reversing, Inverter Bypass, Supply Fan Inverter Bypass Box M3-39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Reversing, Inverter Bypass, Return Fan Inverter Bypass Box M4-50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M60, 6 Contactors, Energy Recovery Wheel Motor Main Control Box MCB Microtech III Control Board Main Control Box Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 7

18 Electrical Legend Continued Schematic Sym. Description Location MJ Mechanical Jumpers All Control Boxes MMP, 3 Manual Motor Protectors, Compressors Main Control Box MMP0 Manual Motor Protector, Supply Fan Main Control Box MMP- 8 Manual Motor Protectors, Condenser Fans Ckt. Main Control Box MMP20 Manual Motor Protector, Return fan Main Control Box MMP2-28 Manual Motor Protectors, Condenser Fans Ckt. 2 Main Control Box MMP30 Manual Motor Protector, Inverter Bypass Supply Fan Inverter Bypass Box MMP40 Manual Motor Protector, Inverter Bypass Return Fan Inverter Bypass Box MMP5-53 Manual Motor Protectors, Exhaust Fan(s) Prop Exhaust Box MMP60, 6 Manual Motor Protector, Energy Recovery Wheel Main Control Box MP- 4 Motor Protectors, Compressors On Compressors OAE Enthalpy Control, Outside Air Economizer Section OAT Temperature Sensor, Outside Air Economizer Section OL6 Overload- Energy Recovery Wheel () Main Control Box PB, 2 Powerblock, Power Distribution Main Control Box PB3 Powerblock, Power Distribution, Electric Heat Electric Heat Section PB4 Powerblock, Power Distribution, Condenser Cond. Control Box PB9, 0 Powerblocks, Supply Fan Junction Box, Split Unit PB, 2 Powerblocks, Power Distribution Main Control Box PB9, 20 Powerblocks, Return/Exhaust Fan Junction Box, Split Unit PC5 Pressure Control, Clogged Filter Pre Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Section PT, 2 Pressure Transducers, SpeedTrol Pressure/Cond. Box PVM, 2 Phase Voltage Monitors Main Control Box R Relay, Cond. Fan SpeedTrol Inverter Enable Pressure/Cond. Box R7 Relay, Cond. Fan 2 SpeedTrol Inverter Enable Pressure/Cond. Ctrl. Box R20 Relay, Gas/Steam/Hot Water Furn./Main Ctrl. Box R2, 22 Relays, Gas Heat, 20: High Turndown Furn./Main Ctrl. Box R23 Relay, Gas Heat Furnace Section R24 Relay, Gas Heat Alarm Main Control Box R25 Relay, Gas Heat, Start Supply Fan Inverter Main Control Box R26 Relay, Isolation/Exhaust Dampers Main Control Box R28 Relay, Isolation Damper Safety Main Control Box R38-40 Relays, Compressor Inverter Heater & Fans Compressor Control Box R45 Relay, UV Lights Main Control Box RAE Enthalpy Sensor, Return Air Return Air Section RAT Temperature Sensor, Return Air Return Air Section REC Receptacle, Main Box Main Control Box REC2 Receptacle, Condenser Box Cond. Control Box REC3 Receptacle, Field Power, 5VAC Discharge Bulkhead REC0-23 Receptacles, Cabinet Sections Cabinet Sections RHB, 2 Interface Board, Modulating Hot Gas Reheat Main Control Box S Switch, System On/Off Main Control Box S3 Switch, Furnace On/Off Furnace Section S4 Switch, Inverter Bypass On/Off Main Control Box S40-45 Switches, Door Interlock, UV Lights Cabinet Sections SC Speed Control, Circuit # Cond. Bulkhead SC2 Speed Control, Circuit #2 Cond. Bulkhead SD Smoke Detector, Supply Air Discharge Section Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 8

19 Electrical Legend Continued Schematic Sym. Description Location SD2 Smoke Detector, Return Air Return Air Section SHS Sensor, Space Humidity Return Section (Field inst.) SPS, 2 Sensors, Static Pressure, Duct or Building Main Control Box SV, 2 Solenoid Valves, Liquid/Drop Condenser Section T Transformer, Main Control, Line/5VAC Main Control Box T2 Transformer, Control Input, 5/24VAC Main Control Box T3 Transformer, Control Output, 5/24VAC Main Control Box T6 Transformer, Factory Powered outlet, Line/5VAC Condenser Section T7 Transformer, Hot Gas Reheat, 5/24VAC Main Control Box T Transformer, SpeedTrol, Line/240VAC Condenser Section TB Terminal Block, Internal for Transformers Main Control Box TB2 Terminal Block, Field Main Control Box TB3 Terminal Block, Factory, 5/24VAC Main Control Box TB4 Terminal Block, Field, 5VAC Main Control Box TB7 Terminal Block, 5VAC Convenience Outlet Main Control Box TB Terminal Block, Heating Furn./Elect. Heat Ctrl. Box TB4 Terminal Block, Inverter Compressor Control Box Compressor Control Box TB25-28 Terminal Blocks, Split Unit Junction Box Split Unit Junction Box TB35-37 Terminal Blocks, Pressure Controls Pressure Control Box TD20 Time Delay, Return Air Fan Main Control Box TR, 2 Transducer, Pressure, SpeedTrol Main Control Box VFD/AFD2 Adjustable Frequency Drive, Inverter Compressor Compressor Control Box VFD/AFD0 Adjustable Frequency Drive, Supply Fan Draw thru/supply Section VFD/AFD, 2 Adjustable Frequency Drive, Cond. Fan SpeedTrol Pressure Control Box VFD/AFD20 Adjustable Frequency Drive, Return/Exhaust Fan Dr. Thru/Ret./Exh. Section VFD/AFD60 Adjustable Frequency Drive, Energy Recovery Wheel Energy Recovery Section UV Ultra-Violet Light(s) Coil/Discharge Section VM Valve Motor #, Heating Furnace/Heating Section VM5 Valve Motor #5, Cooling Coil Section, Cooling VV Vent Valve, Gas Heat Furnace Section ZNT Sensor, Zone Temperature Field Installed Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 9

20 Section A- Outdoor/Return Air Section Notes Primary Codes that pertain: 9, 20, 2, 22, 58 Additional Codes that pertain: 06, 09, 4, 5, 6, 7, 23, 24, 33, 48, 49 Codes 9 and 20 determine the base section. Code 9 is the Return Air Plenum and determines if the unit has Back/Horizontal Return Air, Bottom Return Air, Left, or Right Side discharge. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 20= BE, DE, EE, FE, GE). The only case in which a Plenum is not required is when a 00% Outdoor Air Damper and Hood are ordered (Code 20= AE). For units with Heat/Energy Recovery (Code 20= E, 2E, 3E) see Section A2. Code 2 determines the Return Fan size and type. Code 22 determines the Return Fan Motor horsepower and type. Code 58 determines the drive selection. These codes only pertain to units with a 0-00% Economizer (Code 20= DE, EE, FE, GE). The Return Air Fan Section parts, the Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 09, unit voltage, is part of the Return Fan Motor part number identification. Codes 4 & 5 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4= 2, 4 there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/ AFD2] located in its' own Control Box. Codes 4 and 5 DO NOT apply to this inverter.) For Return Air Section inverter part numbers, refer to Section F the Supply Air Section. Code 6 determines if the unit has a Smoke Detector located in the Return Air cabinet. If Code 6=, 3 a Smoke Detector (SD2) is present in the Return Air Section. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 23 indicates the presence of Plenum/Vestibule Lights, UV lights, 5V Service Outlet, and/or Intelligent Equipment. Code 24 indicates the presence of Exhaust Fans. Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for Gauge part number and description. Code 33 also indicates if the unit is California Title 24 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Light (Code 49= E), Fan Belt Guards (Code 49= D) or both (Code 49= F). Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 20

21 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood AND No Return Air Plenum Code 20= AE AND Code 9= YY 4 Section B 6 4 Ref. Part Part Qty. No. Description Number 4 Damper Assembly Hood Channel This Damper assembly does NOT include an Actuator or Actuator Linkage. A list of component parts follows this page. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 2

22 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood AND No Return Air Plenum Code 20= AE AND Code 9= YY Motorized Linkage Detail Damper Assy Detail Ref. Part Part Qty. No. Description Number Damper Assy Linkage Rod Crank Arm Operator Linkage Rod Actuator Support Damper Blade Damper Seal Damper Stop Linkage Bar Ball Joint Actuator Motor ACT Bushing Bushing Gasket Gasket Damper End Plug Damper End Plug Damper End Plug Bearing Retainer Bracket Nut, Hex Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 22

23 Section A- Outdoor/Return Air Section 0-30% Outside Air Section Damper Code 20= BE AND Code 9= BY, HY Linkage Detail Ref. Part Part Qty. No. Description Number Damper Assembly Damper Damper Blade Gasket Gasket End Seal Motor Support Linkage Bar Shaft Linkage Exhaust Louver N/S Screen Only End Plug End Plug Bushing Bushing Ball Joint Actuator Motor ACT Damper Crank Arm Mounting Plate Screw x Screw x Retainer N/S= Not shown on diagram. Assembly includes Damper, Damper Linkage, and Actuator. 2 Damper ONLY, no Linkage or Actuator components. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 23

24 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Barometric Exhaust Damper Units without Return Air Fans Code 20= DE, EE, FE, GE, AND Code 2= YYYY 60 Back Return (Code 9= HY) shown. 00 Ref. Part Part Qty. No. Description Number 00 Economizer Damper Exhaust Damper Assy N/S Damper Only N/S Exhaust Louver N/S Louver Screen only N/S= Not Shown on diagram. This Damper assembly does not include an Actuator or Actuator Linkage. A list of component parts is two pages previous to this page. 2 The Exhaust damper assembly includes the Damper and Side Baffles. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 24

25 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units with 5" Forward Curved Return Air Fans Code 20= DE, EE, FE, GE AND Code 2= 5** Unit Sizes 06-03D only Bottom Return (Code 9= BY, BB) shown. Ref. Part Part Qty. No. Description Number 0-00% Economizer Damper Actuator/linkage Assy (C20= DE) Actuator Only Damper Assy Barometric (C20= DE, FE) Power (C20= EE, GE) Damper Only Gasket Gasket Belt Guard- LH Belt Guard- RH Deflection Screen This Damper assembly does not include an Actuator or Actuator Linkage. A list of component parts is three pages previous to this page. 2 Code 49= D, F. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 25

26 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units with 30" Air Foil Return Air Fans Code 20= DE, EE, FE, GE AND Code 2= 30** 2 Bottom Return (Code 9= BY) shown Ref. Part Part Qty. No. Description Number 0-00% Economizer Damper Actuator/linkage Assy (C20= DE) Actuator Only Damper Assy. Barometric (C20= DE, FE) Power (C20= EE, GE) Damper Only Belt Guard Gasket This Damper assembly does not include an Actuator or Actuator Linkage. A list of component parts is four pages previous to this page. 2 Code 49= D, F. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 26

27 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units with 40" Air Foil Return Air Fans Code 20= DE, EE, FE, GE AND Code 2= 40** Unit Sizes 035, 042D only 2 24 Bottom Return (Code 9= BY) shown Ref. Part Part Qty. No. Description Number 0-00% Economizer Damper Actuator/linkage Assy (C20= DE) Actuator Only Damper Assy Barometric (C20= DE, FE) Power (C20= EE, GE) Damper Only Belt Guard Gasket Fan Guard This Damper assembly does not include an Actuator or Actuator Linkage. 2 Code 49= D, F. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 27

28 Section A- Outdoor/Return Air Section 0-00% Economizer Assembly Code 20= DE, EE, FE, GE Diagrams Actuator and Actuator Linkage Detail Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 28

29 Section A- Outdoor/Return Air Section 0-00% Economizer Assembly Code 20= DE, EE, FE, GE Components Ref. Part Part Qty. No. Description Number Damper Assembly Channel Linkage Rod Crank Arm Operator Linkage Rod Bottom Support Top Support Block Off Motor Mount Side Support Damper Blade Outside Seal Center Seal Damper Stop Linkage Bar Linkage Bar Ball Joint Actuator Motor- ACT Bushing Bushing Gasket Gasket End Plug End Plug End Plug Bearing Mount This Damper assembly does not include an Actuator or Actuator Linkage. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 29

30 Section A- Outdoor/Return Air Section California Title 24 Assembly Code 33= *F*** Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch Bracket, Mounting Switch Switch, Push Button SPDT Bushing, Conduit 3630 Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 30

31 Section A- Outdoor/Return Air Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE AND Code 2= 5F*, YYYY Ref. Part Part Qty. No. Description Number 0 Damper Assembly 24 x 82" w/ ACT Motor Mount Damper Blade Damper Linkage Actuator Motor- ACT Damper Shaft Damper Ball Joint Damper Blade Gasket Retainer Bearing, sleeve flange The Damper Gasket is sold in 0 foot lengths feet required per Blade. 2 For units with 24" Fans (Code 2= 24B*) OR 40" Fans (Code 2= 40B*) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 3

32 Section A- Outdoor/Return Air Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE AND Code 2= 30B* Ref. Part Part Qty. No. Description Number 0 Damper Assembly 30 x 76" w/ ACT Motor Mount Damper Blade Damper Linkage Actuator Motor- ACT Damper Shaft Damper Ball Joint Damper Blade Gasket Retainer Bearing, sleeve flange The Damper Gasket is sold in 0 foot lengths feet required per Blade. 2 For units with 24" Fans (Code 2= 24B*) OR 40" Fans (Code 2= 40B*) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 32

33 LH Louvered Door Assy Section Final Assembly Section A- Outdoor/Return Air Section Design Flow Code 20= FE, GE, JE Louvered Door Assembly Detail RH Louvered Door Assy Design Flow Vane and Vane Bearings Detail Adjuster Control Assy Detail Spring Detail Ref. Part Part Qty. No. Description Number Louver Panel Units with no Return Fan (40" Door) Left Hand Door Units with no Return Fan (40" Door) Right Hand Door Units with 30" OR 40" Return Fan (52" Door) Left Hand Door Units with 30" OR 40" Return Fan (52" Door) Right Hand Door Grille Units with no Return Fan (40" Door) Units with 30" OR 40" Return Fan (52" Door) Gasket Potentiometer O-Ring, Potentiometer Seal Panel- Vane Shaft- Upper Bearing- Lower Crank Arm Assy Left Hand Door Crank Arm Assy Right Hand Door Link Arm 20 Bearing Bearing Spring- Main Spring- Secondary N/S Leveling Kit- Design Flow P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 33

34 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 5" Forward Curved Fan Code 2= 5F, 5F2, 5F Rubber-In-Shear (RIS) Mount Code 2= 5F Ref. Part Part Qty. No. Description Number 2 Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 2 6 Top View 2 64 Pos. 62 Seismic strap used only when Code 2= 5F Pos. 3 Air Flow Pos. 4 Spring Mount Code 2= 5F2 AND Seismic Mount Code 2= 5F3 Ref. Part Part Qty. 2 No. Description Number 2 Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Standard Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position 3 Seismic 3 Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position 4 Standard Motor H.P.= All Spring Isolator- Position 4 Seismic 3 Motor H.P.= All Spring Isolator- Position 2 Standard Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position 2 Seismic 3 Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Standard Motor H.P.= All Spring Isolator- Position Seismic 3 Motor H.P.= All Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used when Code 2= 5F3. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 34

35 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 30" and 40" Airfoil Fan Code 2= 30B, 40B, 30B2, 40B2, 30B3, 40B Rubber-In-Shear (RIS) Mount Code 2= 30B, 40B Ref. Part Part Qty. No. Description Number 2 Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Washer Drawing is common to all four corners. Quantities listed are for ONE mount. Spring Mount Code 2= 30B2, 40B2 AND Seismic Mount Code 2= 30B3, 40B3 Diagram Seismic strap used only when Code 2= **B Pos. 2 6 Pos. 3 Top View 64 Pos. 62 Air Flow Pos. 4 Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 35

36 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 30" and 40" Airfoil Fan Code 2= 30B2, 30B3 Spring Mounting Code 2= 30B2, and Seismic Mount Code 2= 30B3 Components Ref. Part 30" Qty. No. Description Fan 2 Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Standard Motor H.P.= thru Motor H.P.= 5 thru Spring Isolator- Position 3 Seismic 2 Motor H.P.= thru Motor H.P.= 5 thru Spring Isolator- Position 4 Standard Motor H.P.= All Spring Isolator- Position 4 Seismic 2 Motor H.P.= All Spring Isolator- Position 2 Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 2 Seismic 2 Motor H.P.= thru Motor H.P.= Spring Isolator- Position Standard Motor H.P.= All Spring Isolator- Position Seismic 2 Motor H.P.= All Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Quantity shown is for ONE mount. 2 This part is used when Code 2= 30B3. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 36

37 Section A- Outdoor/Return Air Section Return Air Fan Mounting- 30" and 40" Airfoil Fan Code 2= 40B2, 40B3 Spring Mounting Code 2= 40B2, and Seismic Mount Code 2= 40B3 Components Ref. Part 40" Qty. No. Description Fan 2 Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 3 Seismic 2 Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 4 Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 3 Seismic 2 Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 2 Standard Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 2 Seismic 2 Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position Standard Motor H.P.= All Spring Isolator- Position Seismic 2 Motor H.P.= All Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Quantity shown is for ONE mount. 2 This part is used only when Code 2= 40B3. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 37

38 Section A- Outdoor/Return Air Section Return Air Fan Deck 5" Fans: Code 2= 5F, 5F2, 5F Motor A Ref. Part Part Qty. No. Description Number 6 Wheel/Housing Assy Motor Shelf Filler Piece Shaft Tube Coupling N/S Tube Clamp Grease Fitting/Zerk A Coupling/Reducer Shim Ball Bearing Key Key Motor Mount Bolt N/S= Not shown on diagram. Motors are listed after the fan deck details. 2 Shims are used as needed. Any of the following may be used: (.058"); (.046"); (0.22"); (.03"). Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 38

39 Section A- Outdoor/Return Air Section Return Air Fan Deck 30" Fans: Code 2= 30B, 30B2, 30B3 9A Motor Ref. Part Part Qty. No. Description Number Bearing Funnel- Inlet Wheel- Fan Mount- Motor Shaft- Fan Tubing- Plastic Fitting- Grease A Fitting- Reducer Key Key Motors are listed after the fan deck details. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 39

40 Section A- Outdoor/Return Air Section Return Air Fan Deck 40" Fans: Code 2= 40B, 40B2, 40B Motor Ref. Part Part Qty. No. Description Number 2 Inlet Funnel Bearing Support Lower Bearing Support Fan Wheel: SISW Fan Motor Mount Baffle Support Shaft Coupling Coupling Plastic tubing Grease Fitting Bearing Shaft Key Shaft Key Motors are listed after the fan deck details. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 40

41 Section A- Outdoor/Return Air Section Return Air Fan Motors Standard Motors: Code 22= **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff TEFC HiEff TEFC PrEff Code 22= Voltage C22= *EY C22= *JY C22= *HY C22= *KY C09= 2 E*Y 208/60/ F*Y 208/60/ G*Y 208/60/ H*Y 208/60/ J*Y 208/60/ K*Y 208/60/ L*Y 208/60/ M*Y 208/60/ N*Y 208/60/ C09= 29 E*Y 230/60/ F*Y 230/60/ G*Y 230/60/ H*Y 230/60/ J*Y 230/60/ K*Y 230/60/ L*Y 230/60/ M*Y 230/60/ N*Y 230/60/ C09= 27 E*Y 460/60/ F*Y 460/60/ G*Y 460/60/ H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ C09= 37 E*Y 575/60/ F*Y 575/60/ G*Y 575/60/ H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 4

42 Section A- Outdoor/Return Air Section Return Air Fan Motors Shaft Grounded Motors: Code 22= **S H.P. Motor HP Unit ODP PrEff TEFC PrEff C22= **S Voltage C22= *JS C22= *KS C09= 2 E*S 208/60/ N/A.5 F*S 208/60/ N/A 2 G*S 208/60/ N/A 3 H*S 208/60/ J*S 208/60/ K*S 208/60/ L*S 208/60/ M*S 208/60/ N*S 208/60/ C09= 29 E*S 230/60/ F*S 230/60/ G*S 230/60/ H*S 230/60/ J*S 230/60/ K*S 230/60/ L*S 230/60/ M*S 230/60/ N*S 230/60/ C09= 27 E*S 460/60/ F*S 460/60/ G*S 460/60/ H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ C09= 37 E*S 575/60/ F*S 575/60/ G*S 575/60/ H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ N/A= Not Available. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 42

43 Section A- Outdoor/Return Air Section Section Mounted Controls OAE, RAE, LT, S, REC Bottom Return Shown Code 9= BY, BE Economizer Damper 40 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Bottom Return Shown Code 9= BY, BE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Mount- RAE Enthalpy Control- RAE RAT- Return Air Temperature Sensor 7 Ref. Part Part Qty. No. Description Number 7 Sensor- RAT Return Air Opening 30 Return Air Opening SD2- Return Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 30 Smoke Detector SD Back Return Code 9= HY Bottom Return Code 9= BY, BE LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Light Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 43

44 Section A2- Outdoor/Return Air w/ Heat Recovery Section Notes Primary Codes that pertain: 9, 20, 2, 22, 24, 58 Additional Codes that pertain: 06, 09, 4, 5, 6, 7, 23, 33, 48, 49 Codes 9 and 20 determine the base section and Return Air Plenum. Code 20 determines the type of Outdoor Air/Heat Recovery control used. Code 20= E, 2E are 00% OA Air units. Code 20= 3E indicates that the unit has an Economizer. Code 2 determines the Return Fan size and type. Code 22 determines the Return Fan Motor horsepower and type. Code 58 determines the drive selection. The fan section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 24 determines if the Heat/Energy Recovery Wheel has a Frost Protection Inverter. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air With Heat Recovery Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 09, the voltage, is part of the Return Fan Motor part number identification. Codes 4 & 5 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4= 2, 4 there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the inverter vendor. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its' own Control Box. Codes 4 and 5 DO NOT apply to this inverter.) For Return Air Section Inverter part numbers, refer to Section F the Supply Air Section. If Code 6=, 3 a Smoke Detector (SD2) is present in the Return Air Cabinet. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 23 indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/HGRH inverter brand specified, and/or the presence of Intelligent Equipment. Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for part number and description. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Light (Code 49= E), Fan Belt Guards (Code 49= D) or both (Code 49= F). Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 44

45 Section A2- Outdoor/Return Air w/ Heat Recovery Section 00% Outside Air Low Flow- Code 20= E Intake Hood (see detail to left) Outdoor Air Intake Hood Detail LH or 49 RH Exhaust Hood Detail Ref. Part Part Qty. No. Description Number Fan Assembly 2 Damper Assy- Low Leak Panel, Top- Hood Panel, LH Side- Outdoor Air Intake Hood Panel, RH Side- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Lower Louver- Outdoor Air Intake Hood Screen- Outdoor Air Intake Hood Gasket ft. 60 Wheel, Enthalpy- Heat Recovery 3 6 Motor- Enthalpy Wheel 3 62 Sheave- Fixed 3 20 Filter Rack Filter Rack Filter Rack Filter Rack Door, Indented- Exhaust LH Door, Indented- Exhaust RH Exhaust Hood N/S Filter 6 x 20 x N/S Filter 6 x 25 x N/S= Not Shown on Diagram. See Detail two pages after next. 2 See Detail four pages after next. 3 See Detail in this section (A2) titled "Heat Recovery-Enthalpy-Wheel Detail (Ref #60) Wheel Motor, Drive Components, Seals" Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 45

46 Section A2- Outdoor/Return Air w/ Heat Recovery Section 00% Outside Air High Flow- Code 20= 2E Hood (see detail to left) Outdoor Air Intake Hood Detail LH or 49 RH Exhaust Hood Detail Ref. Part Part Qty. No. Description Number Fan Assembly 2 Damper Assy- Low Leak Panel, Top- Hood Panel, LH Side- Outdoor Air Intake Hood Panel, RH Side- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Lower Louver- Outdoor Air Intake Hood Screen- Outdoor Air Intake Hood Gasket ft. 60 Wheel, Enthalpy- Heat Recovery Motor- Enthalpy Wheel Sheave- Fixed Filter Rack Filter Rack Filter Rack Filter Rack Door, Indented- Exhaust LH Door, Indented- Exhaust RH Exhaust Hood N/S Filter 6 x 20 x N/S Filter 6 x 25 x N/S= Not Shown on Diagram. See Detail one page after next. 2 See Detail four pages after next. 3 See Detail in this section (A2) titled 'Heat Recovery-Enthalpy-Wheel Detail (Ref #60) Wheel Motor, Drive Components, Seals". Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 46

47 Section A2- Outdoor/Return Air w/ Heat Recovery Section Economizer- Code 20= 3E Outdoor Air Intake Hood Detail Intake Hood Exhaust Hood Detail LH or 49 RH A Ref. Part Part Qty. No. Description Number Fan Assembly 2 Damper Assy- Low Leak 2 Outdoor Air (w/ ACT3) A Damper Assy- Low Leak 2 Return Air (w/ ACT4) Panel, Top- Hood Panel, LH Side- Outdoor Air Intake Hood Panel, RH Side- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Louver- Outdoor Air Intake Hood Panel, Lower Louver- Outdoor Air Intake Hood Screen- Outdoor Air Intake Hood Gasket ft. 60 Wheel, Enthalpy- Heat Recovery 3 6 Motor- Enthalpy Wheel 3 62 Sheave- Fixed 3 20 Filter Rack Filter Rack Filter Rack Filter Rack Damper Assy- Bypass Door, Indented- Exhaust LH Door, Indented- Exhaust RH Exhaust Hood N/S Filter 6 x 20 x N/S Filter 6 x 25 x N/S= Not Shown on Diagram. See Detail on next page. 2 See Detail two pages after next. 3 See Detail in this section (A2) titled "Heat Recovery-Enthalpy-Wheel Detail (Ref #60) Wheel Motor, Drive Components, Seals". 4 See Detail three pages after next. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 47

48 Section A2- Outdoor/Return Air w/ Heat Recovery Section 24" Return Fan Detail Code 2= 24B* AND Code 20= *, 2*, 3* Ref. Part Part Qty. No. Description Number Motor- Return Fan 6 Mount- Motor Inlet Funnel Bearing- Ball,.687" Bearing- Ball,.687" Shaft,.687" Key- Shaft Wheel, 24" AF See Return Fan Motor Tables for p/ns. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 48

49 Section A2- Outdoor/Return Air w/ Heat Recovery Section 24" Return Fan Detail Fan Mounts Fan Mounting Locations Top View Rubber-In-Shear (Code 2= 24B) Ref. Part Part Qty. No. Description Number Mount- RIS Mount- Channel Nut Screw Screw, Cap Nut Washer Screw, Cap Seismic strap used only when Code 2= 24B Spring (Code 2= 24B2) OR Spring w/ Seismic Snubber (Code 2= 24B3) Ref. Part Part Qty. No. Description Number Spring-.5-0 HP Yellow , 35 Spring HP Green , 37 Spring HP Yellow Mount- Std. (Code 2= 24B2) Mount- Seismic (Code 2= 24B3) Nut Screw Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 49

50 Section A2- Outdoor/Return Air w/ Heat Recovery Section Low Leak Damper Detail, Part No (Ref. #2 OR 2A) Damper, Actuator (ACT3 - OA Damper and ACT 4 - RA Damper) ACT3 OR ACT4 Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator Complete Assy- Less Actuator Seal- End Stop- Damper End Plug Blade- Damper Actuator- ACT3, 4 24V End Plug End Plug Bushing- Linkage Bushing- Damper Blade Shaft- Drive Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 50

51 Section A2- Outdoor/Return Air w/ Heat Recovery Section Low Leak Bypass Damper Detail, Part No (Ref. #230) Damper, Actuator (ACT2) Economizer Units (Code 2= 3E) ACT Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator Complete Assy- Less Actuator Seal- End Stop- Damper End Plug End Plug End Plug Blade- Damper Actuator- ACT2 24V Coupling- Shaft End Plug End Plug Bushing- Linkage Bushing- Damper Blade Shaft- Drive Lock Collar Gasket- Vinyl 7" L Gasket- Vinyl 7" L Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 5

52 Section A2- Outdoor/Return Air w/ Heat Recovery Section Heat Recovery Enthalpy Wheel Detail (Ref. #60) Wheel, Motor, Drive Components, Seals Outdoor Air Out (Supply) Exhaust Air In (Return) Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 208/230/ Wheel Assy- Complete Wheel 2 Segmented Motor 208/230/ Motor Sheave Bearing Shaft " x 7.7" Belt 6.' N/S Inner/Outer Seal N/S= Not Shown on diagram. Includes Motor, Shaft, Belt etc. 2 If a replacement Wheel is required, it is suggested that this part number be used. This segmented Wheel ships disassembled which allows for easier shipping and installation. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 52

53 Section A2- Outdoor/Return Air w/ Heat Recovery Section VFD60 Frost Protection Inverter (Code 24= F) 00% OA Low Flow (Code 20= E) 00% OA Hi Flow (Code 20= 2E) Economizer (Code 20= 3E) Rear Filter Rack Upright 3 Rear Support Cross Member 3 Mid- Section Upright Rear Filter Rack RA Damper Assy Base Rail Mid- Section Junction Box Base Rail 3 Voltage Ref. Sch. Part Part No Sym. Description Number 3 Code 23= **A** VFD60 Inverter Inverter Inverter Code 23= **B** VFD60 Inverter Inverter Inverter Code 23= **Q** VFD60 Inverter Inverter Inverter For the fusing for VFD60, refer to the "Energy Recovery Wheel Contactors, MMPs, & Fusing page in Section N. 2 The replacement VFD Keypad is p/n V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 53

54 Section A2- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls OAE, RAE, RAT, EAT, LAT Bottom Return Shown Code 9= BY, BE Economizer Damper 40 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Bottom Return Shown Code 9= BY, BE Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Mount- RAE Enthalpy Control- RAE RA Opening 84 Deck Panel 200 RAT- Outdoor Air Temperature Sensor Ref. Part Part Qty. No. Description Number 84 Support- RAT Sensor- RAT EAT- Entering Air Temperature Sensor Return Fan Ref. Part Part Qty. No. Description Number 422 Support- EAT Sensor- EAT LAT- Leaving Air Temperature Sensor Ref. Part Part Qty. No. Description Number 582 Support- LAT Sensor- LAT Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 54

55 Section A2- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls SD2, HUM, LT, S, REC Heat Wheel RA Opening SD2- Return Air Smoke Detector (Code 6=, 3) Ref. Part Part Qty. No. Description Number 227 Support- SD Smoke Detector- SD Return Air Opening RAT Deck Panel HUM- Humidistat (units with frost protection) Code 24= F Ref. Part Part Qty. No. Description Number 596 Support- HUM 2/6 & Earlier 0780 /7 & Later Humidistat- HUM 2/6 & Earlier /7 & Later This is the duct mounted Humidistat. If a unit has a wall mounted Humidistat use p/n LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Light Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 55

56 Section B- DrawThru Filter/Blank Section Notes Primary Codes that pertain: 25, 33, 50 Additional Codes that pertain: 06, 9, 20 Code 25 determines the section's filter characteristics. If the first digit of Code 25= A the Filters are in an angular rack, and if the first digit = F the Filters are in a flat rack. If the second digit = B there are 30% eff. throwaway filters, if C there are 30% eff. throwaway filters with Antimicrobial Intersept and if H there are 85% eff. throwaway filters. If the second digit = D there are 65% eff. filters, if E there are 95% eff. filters, and if G there are 95% eff. filters with Antimicrobial Intersept. If the second digit = Y there is no filter media specified. If Code 25 = BY, CY there is a blank section. Code 33 indicates the presence of a Magnehelic/Differential Filter gauge. Code 50 indicates the presence of an Air Blender in a 52" section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank Access Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Codes 9 and 20 determine the Return Air section which has an effect on the final assembly panels. Section B- DrawThru Filter/Blank Section Air Blender (Code 50= L, H) 68 Ref. Part Code 50= Part Qty. No. Description Number 68 Air Blender Low CFM L High CFM H Section B- DrawThru Filter/Blank Section Section Mounted Controls PC5- Clogged Filter Control Ref. Part Part Qty. No. Description Number 65 Pressure Ctl.- PC Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 56

57 Section B- DrawThru Filter Section Filters, Filter Section Components & Magnehelic/Differential Pressure Gauge Typical Angular Filter Section Shown Code 25= A* Filter Section Parts Ref. Part Code Part Qty. No. Description 25= Number Angular Filter Section (Code 25= A*) N/S Filter 30% Pleated, 6 x 25 x 2" MERV 8 *B % Pleated, 6 x 25 x 2" w/ Intersept MERV 8 *C % Pleated, 6 x 25 x 2" MERV 3 *H N/S Filter 30% Pleated, 6 x 20 x 2 MERV 8 *B % Disposable, 6 x 20 x 2" w/ Intersept MERV 8 *C % Pleated, 6 x 20 x 2 MERV 3 *H N/S Media Filler Piece ALL Flat Filter Section (Code 25= F*) N/S Filter 65% Cartridge, 24 x 24 x 2" MERV *D % Cartridge, 24 x 24 x 2" MERV 4 *E % Cartridge, 24 x 24 x 2" w/ Intersept MERV 4 *G N/S Filter 65% Cartridge, 2 x 24 x 2" MERV *D % Cartridge, 2 x 24 x 2" MERV 4 *E % Cartridge, 2 x 24 x 2" w/ Intersept MERV 4 *G N/S Pre Filter, 30% N/S Pre Filter, 30% N/S Gasket- /4" x /2" N/S Gasket- Dbl Magnehelic/Differential Pressure Gauge Code 33= A****, B****, C**** Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0-3 WC Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 57

58 Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes Primary Codes that pertain: 26, 4, 5 Additional Codes that pertain: 06 Code 26 determines if a section is installed and if so, the size of the section. If Code 26= A there is a Blank/ Empty 22" section. If Code 26= C the section is 40" and if Code 26= D the section is 52". If Code 26= Y, there is no section. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4=, 2, 4 there is a separate Inverter Section. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4= Y, there are no inverters. Code 5 specifies the inverter vendor. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its' own Control Box. Codes 4 and 5 DO NOT apply to this inverter.) All components pertaining to the inverter(s) are listed in the Supply Air Section (Section F). Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Blank Access/Inverter Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Return Air Inverter (AFD20) Supply Air Inverter (AFD0) Section Mounted Controls LT2, S2, REC LT2- DT Access Section Light/S2- DT Access Section Light Switch/REC2- DT Access Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 58

59 Section D- DrawThru Cooling Section Notes Primary Codes that pertain: 27, 28 Additional Codes that pertain: 06 NOTE: Section D applies only to unit sizes 035 and 042D. The DrawThru Cooling Coil and associated components for unit sizes 06-03D are located in Section F (Supply Air Section). Code 27 determines if there is a Section D. If Code 27= YYYY, there is no section. If the first three digits of Code 27= CYY this is a cooling unit with a 22" section between the Filter and Supply Fan Sections. If the first three digits of Code 27= DYY then the section contains only a Drain Pan. If the first three digits of Code 27= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 27= S, the Drain Pan is stainless steel. P in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 27= T, then the unit is equipped with a wider than standard painted galvanized steel Drain Pan. If the fourth digit of Code 27= L, T then the first three digits of Code 27 must equal DYY. Code 28 determines Cooling Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 59

60 Section D- DrawThru Cooling Section Evaporator Coil Drain Pans and Gaskets Code 27= CYYP, CYYS- 22" Section- Unit Sizes 035, 042D Unit Base 4 Ref. Part Code 27= Part Qty. No. Description Number 3 Coil- refer to the following page 3 Drain Pan- Auxiliary CYYP, CYYS Drain Pan- Main Galvanized CYYP Stainless Steel CYYS Gasket ft. Drain Pans Code 27= DYYP, DYYS- 40" Section- Unit Sizes 035, 042D Diagram and Components 03 Unit Base Ref. Part Drain Pan Material Code 27= Qty. No. Description DYYP- Galvanized DYYS- Stainless 03 Drain Pan For Drain Pans and components when Code 27= GYY* and/or Code 27 Digit 4= L, T contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 60

61 Section D- DrawThru Cooling Section Evaporator Coils Unit Sizes 035, 042D Typical Coil Description Code 28= 4Z 08 3 D Fin Stock C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) Rows 3= 3 Row Coil 4= 4 Row Coil 5= 5 Row Coil 6= 6 Row Coil Fins-per-inch 08= 8 FPI 0= 0 FPI 2= 2 FPI 4= 4 FPI Coil Model Evaporator Coils are serial number specific. Please contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 6

62 Section E- DrawThru Blank Access Section Notes Primary Codes that pertain: 30 Additional Codes that pertain: 06 If Code 30= AAAAAA there is a Blank/Empty 22" section. If Code 30= CCCCCC there is a Blank/Empty 40" section. If Code 30= YYYYYY, there is no section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Blank Access Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Cabinet Door Gasketing and Hardware Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Section Mounted Controls LT8, REC8, S8- Section Mounted Light LT8- DT/Blank Section Light/S8- DT/Blank Section Light Switch/REC8- DT/Blank Section Receptacle Ref. Part Part Qty. No. Description Number 284 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 62

63 Section F- Supply Air Section Notes Primary Codes that pertain: 3, 32, 59, 4, 5, 49 (all unit sizes); 27, 28 (06-03D only) Additional Codes that pertain: 04, 34, 06, 7, 23, 33 NOTE: The DrawThru Cooling Section for unit sizes 06-03D is located in Section F. Components for the DrawThru Cooling Section for unit sizes 035, 042D are listed in Section D. Code 3 determines the Supply Fan size and type, Code 32 determines the Supply Fan Motor horsepower and type, and Code 59 determines the drive selection. Supply Air Fan Section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Codes 4 and 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4=, 2, 4 there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the Inverter Vendor. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its' own Control Box. Codes 4 and 5 DO NOT apply to this inverter.) Code 49 determines if the Supply Air Fan Section has a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), or both (Code 49= C, F). Codes 27 and 28 determine the DrawThru Evaporator Section, and pertain to the coil and Drain Pan installed in section F for unit sizes 06-03D. If the first three digits of Code 27= CYY this is a cooling unit with the coil located in the Supply Fan Section. If the first three digits of Code 27= DYY then the section contains only a Drain Pan. If the first three digits of Code 27= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 27= S, the Drain Pan is stainless steel; P in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 27= T, then the unit is equipped with a wider than standard painted galvanized steel Drain Pan. If the fourth digit of Code 27= L, T then the first three digits of Code 27 must equal DYY. Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, as well as the section installed controls. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection. Code 23 indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 5V Service Outlet, and/or Intelligent Equipment. Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 23= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 63

64 Section F- Supply Air Section DrawThru Evaporator Coil Drain Pans Unit Sizes 06-03D Code 27= CYYP, CYYS 3 Sizes 06, 08, Sizes 025, 030, Unit Base Unit Base 4 Ref. Part Code Part No. Description 27= Number Coil- refer to the following page 3 Drain Pan- Auxiliary CYYP, CYYS Drain Pan- Main Galvanized/Painted CYYP Stainless Steel CYYS Gasket ft. 5 ft. Drain Pans Unit Sizes 06-03D Code 27= DYYP, DYYS 03 Unit Base Ref. Part Drain Pan Material Code 27= Qty. No. Description DYYP- Galvanized DYYS- Stainless 03 Drain Pan For Drain Pans and components when Code 27= GYY* AND/OR Code 27 Digit 4= L, T, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 64

65 Section F- Supply Air Section Evaporator Coils Unit Sizes 06-03D Typical Coil Description Code 28= 4Z 08 3 D Fin Stock C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) Rows 3= 3 Row Coil 4= 4 Row Coil 5= 5 Row Coil 6= 6 Row Coil Fins-per-inch 08= 8 FPI 0= 0 FPI 2= 2 FPI 4= 4 FPI Coil Model Evaporator Coils are serial number specific. Please contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 65

66 Section F- Supply Air Section Fan Assembly 5" X 6" AND 5" X 5" Forward Curved Fans Code 3= 06F*, 5F* Unit Sizes 06-03D Motor Ref. Part Fan Size: Code 3= Qty. No. Description 06F* 5F* 2 Wheel Assembly Motor Mount Bolt Blower Frame Shaft Filler Piece Tubing Tubing Motor Base Tube Clamp Shim 2 2 Shaft Key Shaft Key Coupling Coupling- Reducer Bearing- Pillow Block N/S Belt Guard Assy N/S= Not Shown on diagram. Any of the following shims may be used: (.022); (.03); (.046); (.046); (.058). 2 Any of the following shims may be used: (.058); (.046); (.046); (.03); (.022). 3 Code 49= A, C, D, F. 4 Motors are listed after the fan mounting section. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 66

67 Section F- Supply Air Section Fan Assembly 20" Airfoil Fans Code 3= 20A, 20A2, 20A3 Unit Sizes 06-03D Motor Ref. Part Part Qty. No. Description Number 2 Blower Housing Wheel: DWAF Motor Mount Bolt Shaft Motor Shelf Shaft Key Shaft Key Bearing N/S Grille- Belt Guard N/S= Not Shown on diagram. Motors are listed after the fan mounting section. 2 Code 49= A, C, D, F. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 67

68 Section F- Supply Air Section Fan Assembly 24" Airfoil Fans Code 3= 24A, 24A2, 24A3 Unit Sizes 035, 042D Wheels- View looking TOWARDS Discharge Opening Motor Ref. Part Part Qty. No. Description Number 2 Blower Housing Wheel: SISW C.W Wheel: SISW C.C.W Shaft Mount- Motor Angle- Mount Angle- Motor Mount Key Key Bearing N/S Belt Guard Assy N/S= Not Shown on diagram. Motors are listed after the fan mounting section. 2 Code 49= A, C, D, F. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 68

69 Section F- Supply Air Section Supply Air Fan Mounting- 5" x 6" Forward Curved Fan Code 3= 06F, 06F2, 06F3 9 Rubber-In-Shear (RIS) Mount Code 3= 06F Ref. Part Part Qty. No. Description Number 2 Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 2 3 Top View 2 34 Pos. 32 Seismic strap used only when Code 3= 06F Pos. 3 Air Flow Pos. 4 Spring Mounting Code 3= 06F2 OR Seismic Mount Code 3= 06F3 Ref. Part Part Qty. 2 No. Description Number 2 Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 7.5 thru Motor H.P.= Spring Isolator- Position 4 Motor H.P.= thru Motor H.P.= Spring Isolator- Position 2 Motor H.P.= thru Motor H.P.= 7.5 thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 0 thru Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 06F3. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 69

70 Section F- Supply Air Section Supply Air Fan Mounting- 5" X 5" Forward Curved Fan Code 3= 5F, 5F2, 5F3 9 Rubber-In-Shear (RIS) Mount Code 3= 5F Ref. Part Part Qty. No. Description Number 2 Support Mount Isolator R- 3 Black Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 2 3 Top View 2 34 Pos. 32 Seismic strap used only when Code 3= 5F Pos. 3 Air Flow Pos. 4 Spring Mounting Code 3= 5F2 OR Seismic Mount Code 3= 5F3 Ref. Part Part Qty. 2 No. Description Number 2 Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 7.5 thru Motor H.P.= Spring Isolator- Position 4 Motor H.P.= All Spring Isolator- Position 2 Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= 5 thru Spring Isolator- Position Motor H.P.= thru Motor H.P.= 0 thru Clinch Nut- Standard Clinch Nut- Seismic Nut Screw- Standard Screw- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 5F3. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 70

71 Section F- Supply Air Section Supply Air Fan Mounting- 20" Airfoil Fan Code 3= 20A, 20A2, 20A Rubber-In-Shear (RIS) Mount Code 3= 20A Ref. Part Part Qty. No. Description Number 2 Support Mount Isolator- Position 3 Motor H.P.= All Isolator- Position 4 Motor H.P.= All Isolator- Position 2 Motor H.P.= thru Motor H.P.= 0 thru Isolator- Position Motor H.P.= All Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount Pos. 2 3 Top View 2 34 Pos. 32 Seismic strap used only when Code 3= 20A Pos. 3 Air Flow Pos. 4 Spring Mounting Code 3= 20A2 OR Seismic Mount Code 3= 20A3 Ref. Part Part Qty. 2 No. Description Number 2 Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 3 thru Motor H.P.= Spring Isolator- Position 4 Motor H.P.= thru Motor H.P.= 7.5 thru Spring Isolator- Position 2 Motor H.P.= thru Motor H.P.= 3 thru Motor H.P.= 7.5 thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= 5 thru Nut Spring Mount- Standard Spring Mount- Seismic Nut Screw Spring Mount- Standard Spring Mount- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 20A3. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 7

72 Section F- Supply Air Section Supply Air Fan Mounting- 24" Airfoil Fan Code 3= 24A, 24A2, 24A3 9 Rubber-In-Shear (RIS) Mount Code 3= 24A Ref. Part Part Qty. No. Description Number 2 Support Mount Isolator RP- 3 Red Clinch Nut Screw Nut Screw Drawing is common to all four corners. Quantities listed are for ONE mount. Spring Mounting Code 3= 24A2 OR Seismic Mount Code 3= 24A Pos. 2 3 Top View 2 34 Pos. 32 Seismic strap used only when Code 3= 24A Pos. 3 Air Flow Pos. 4 Ref. Part Part Qty. 2 No. Description Number 2 Mount- Spring Spring Mount- Standard Spring Mount- Seismic Spring Isolator- Position 3 Motor H.P.= thru Motor H.P.= 5 thru Spring Isolator- Position 4 Motor H.P.= All Spring Isolator- Position 2 Motor H.P.= thru Motor H.P.= 5 thru Motor H.P.= 5 thru Motor H.P.= Spring Isolator- Position Motor H.P.= thru Motor H.P.= 20 thru Nut Spring Mount- Standard Spring Mount- Seismic Nut Screw Spring Mount- Standard Spring Mount- Seismic Drawing is common to all four corners. Quantities listed are for ONE mount. 3 This part is used only when Code 3= 24A3. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 72

73 Section F- Supply Air Section Supply Air Fan Motors Standard Motors: Code 32= **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Code 32= Voltage C32= *EY C32= *JY C32= *HY C32= *KY C09= 2 E*Y 208/60/ F*Y 208/60/ G*Y 208/60/ H*Y 208/60/ J*Y 208/60/ K*Y 208/60/ L*Y 208/60/ M*Y 208/60/ N*Y 208/60/ P*Y 208/60/ C09= 29 E*Y 230/60/ F*Y 230/60/ G*Y 230/60/ H*Y 230/60/ J*Y 230/60/ K*Y 230/60/ L*Y 230/60/ M*Y 230/60/ N*Y 230/60/ P*Y 230/60/ C09= 27 E*Y 460/60/ F*Y 460/60/ G*Y 460/60/ H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ C09= 37 E*Y 575/60/ F*Y 575/60/ G*Y 575/60/ H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 73

74 Section F- Supply Air Section Supply Air Fan Motors Shaft Grounded Motors: Code 32= **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C32= **S Voltage C32= *JS C32= *KS C09= 2 E*S 208/60/ N/A.5 F*S 208/60/ N/A 2 G*S 208/60/ N/A 3 H*S 208/60/ J*S 208/60/ K*S 208/60/ L*S 208/60/ M*S 208/60/ N*S 208/60/ P*S 208/60/ C09= 29 E*S 230/60/ F*S 230/60/ G*S 230/60/ H*S 230/60/ J*S 230/60/ K*S 230/60/ L*S 230/60/ M*S 230/60/ N*S 230/60/ P*S 230/60/ C09= 27 E*S 460/60/ F*S 460/60/ G*S 460/60/ H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ C09= 37 E*S 575/60/ F*S 575/60/ G*S 575/60/ H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 74

75 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP - 5 (Code 22 OR Code 32= E**, F**, G**, H**, J**) Diagrams Inverters may be located in a separate section (Code 4=, 2, 4 [Only inverters WITH bypass may be installed in a separate section.]), or the Supply Air Section (Code 4= 3, 5, 6, 7, 8, 9). The inverter and bypass controls are the same regardless of the installation location, although the sheet metal components differ. The diagrams shown below apply to either a Return or Supply Air Inverter (both may be installed if code 4= 5). Even if Code 4= 8 or 9 where only a Return Air Fan Inverter is called for the inverter and bypass controls are still installed in the Supply Air Section. MMP30 (Supply) 70 LR0 (Supply) 7 MMP40 (Return) 70 LR20 (Return) Supply Air OR Return Air Fan Inverter with Bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code 4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 75

76 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP - 5 (Code 22 OR Code 32= E**, F**, G**, H**, J**) Components Phase Barrier Front Mtd. Aux. Contact 70B 70A MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Link 70C 72 Link 70C 72A Spacer Contactor 72 Contactor MMP30/40 & M30/40 Link Detail - 2 HP Motors- All Voltages 3, 5 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 3, 5 HP Motors- 208/230V Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 20 Inverter- see Inverter section 50 Gasket MMP30, 40 Motor Protector A Phase Barrier B Aux. Contact C Link LR0, 20 Line Reactor M30B, I Contactor M40B, I A Spacer V 230V 208V 230V 208V 230V 208V 230V 208V 230V Line Reactors used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8. 2 These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 76

77 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code 22 = K**, L**, M**, N** OR Code 32= K**, L**, M**, N**, P**) Diagrams 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) MMP30 (Supply) MMP40 (Return) 70 LR0 (Supply) 7 70 LR20 (Return) 7 40 Supply Air AND Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 5, 8) Two boxes installed if C4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Link 70C 72 Link 70C 72A Spacer Contactor 72 Contactor MMP30/40 & M30/40 Link Detail 7.5 HP Motors- Front Mtd. Aux. Contact 70B Link 70C 72 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 208/230V 5, 20 HP Motors- 20 HP Motors- 25 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 7.5 HP Motors- 208/230/ 0, 5 HP Motors- Phase Barrier 70A Front Mtd. Aux. Contact 70B Link 70C 72 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 20, 25 HP Motors- 208/230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 77

78 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code 22 = K**, L**, M**, N** OR Code 32= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 20 Inverter- see Inverter section 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 50 Gasket MMP30,40 Motor Protector A Phase Barrier B Contact- Auxiliary C Link Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 78

79 Section F- Supply Air Section Inverter & Inverter Bypass Control Box Motor HP (Code 22 = K**, L**, M**, N** OR Code 32= K**, L**, M**, N**, P**) Components, Continued Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 7 LR0, 20 Line Reactor V 230V 208V 230V 208V 230V 208V 230V 208V 230V 72 M30B, I M40B, I Contactor 9A A A A A A A A A Spacer Line Reactors used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 79

80 Section F- Supply Air Section Inverters Code 5= A AND/OR Code 23= **A** 208/230V Motor Horsepower /230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Part Number The replacement VFD Keypad Display is p/n Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 80

81 Section F- Supply Air Section Inverters, Continued Code 5= G Motor Horsepower,.5, Part Number V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 8

82 Section F- Supply Air Section Inverters, Continued Code 5= S, Q AND/OR Code 23= **Q** 208/230V Motor Horsepower /230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Part Number , , , , , , , The Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The Lonworks communication card is p/n All other communication cards are integral to the VFD and are NOT available separately. 2 MD3 Remote Keypad p/n is MD6 Remote Keypad p/n is plus Mount p/n For units with an MD3 Inverter and Motor under 25 HP a Line Reactor will be installed regardless of whether one is specified in Code 7 (see nomenclature page). Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 82

83 Section F- Supply Air Section Inverters, Continued Code 5= B AND/OR Code 23= **B** 208/230V Motor Horsepower /230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Part Number The replacement VFD Keypad Display is p/n Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 83

84 Section F- Supply Air Section Section Mounted Controls PC7, EFT, HL22, LT0, S0, REC0, UV Lights PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket Pressure Control- PC Pneumatic Fitting EFT- Entering Fan Temperature Sensor Ref. Part Part Qty. No. Description Number 36 Sensor- EFT Bracket- EFT A 67 HL22- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 67 T-stat- HL22 Hi Limit A Support- HL LT0- Supply Fan Light/S0- Supply Fan Light Switch/REC0- Supply Fan Light Receptacle Code 49= B, E Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC UV Lights Code 7= C thru C8, Y thru Y8 Ref. Part Part Qty. No. Description Number 98 Light Fixture- 8" Bulb Light Fixture- 24" Bulb Light Fixture- 36" Bulb Bulb/Lamp, UV- 8" Bulb/Lamp, UV- 24" Bulb/Lamp, UV- 36" Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 84

85 Section G- BlowThru Heat Section Notes Primary Codes that pertain: 04, 34 Additional Codes that pertain: 06, 07, 09, 2, 3 This section is divided into four subsections:. Blank Access; 2. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat. Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section's characteristics. If Code 04= Y, AND Code 34= YYYYYY there is no section. If Code 04= Y AND Code 34= BBBBBB, then there is a 40" Blank Access Section installed. Refer to the Unit Code Index for heat section coding and definitions. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heating Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is approved for US or Canadian operation. Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls. Code 2 determines the Control type and will affect the Gas Heat Actuator Motor. Code 3 is the Supply Fan size, and affects the heat section's Diffusers. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 85

86 Section G- BlowThru Heat Section Option : Blank/Empty Section Code 34= BBBBBB AND Code 04= Y Diffusers Units with 5" X 6" OR 5" X 5" Supply Fan Code 3= 06F*, 5F* Units with 20" OR 24" Supply Fan Code 3= 20**, 24** 2 2 Ref. Part Part Qty. No. Description Number 2 Diffuser Code 3= 06F*, 5F* Code 3= 20**, 24** Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 86

87 Section G- BlowThru Heat Section Option 2: Hot Water OR Steam Heating Coil Code 04= W, S AND Code 34= W****E, S****E Coils and Coil Compartment Components Diffuser Units with 5" Supply Fan Code 3= 06F*, 5F* Diffuser Units with 20" OR 24" Supply Fan Code 3= 20**, 24** FS Freezestat Ref. Part Part Qty. No. Description Number 2 Coil Steam Coil- 6 FPI/ Row (C34= S***) Steam Coil- 2 FPI/ Row (C34= S2***) Hot Water- 9 FPI/ Row (C34= W***) Hot Water- 9 FPI/2 Row (C34= W22***) 2 Diffuser Code 3= 06F*, 5F* Code 3= 20**, 24** Fin Channel (- Row Coil Only) Bottom Baffle (C36= 5Z**** only) Row Coil (C34= W***, S***) Row Coil (C34= W22***) Freezestat- FS Coils are serial number specific. Contact Daikin Applied with model and serial number information so that the correct coil can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 87

88 Section G- BlowThru Heat Section Option 2: Hot Water OR Steam Heating Coil Code 04= W, S AND Code 34= W****E, S****E Valves Steam Coil Units Code 34= S*2E, S2*2E* Hot Water Coil Units Code 34= W*3E, W22*3E Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number 249 Valve, 2 Way Steam Heat w/ Act..00 S**D2E 5JA All S**E2E 5JA All S**F2E 5JA All S**G2E 5JA All VM Actuator- 24V, HW Heat 2 W***3E All All Valve, 3 Way HW w/ Actuator.00 W**D3E 5WH, 5WS All.25 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All N/S= Not shown on diagram. Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. 2 Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 88

89 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Diffusers, High Limit HL4, HL4 & HL 3-50 Diffusers: Units with 5" Supply Fan Code 3= 06F*, 5F* Heaters, Hi-Limit Switches Diffusers: Units with 20" OR 24" Supply Fan Code 3= 20**, 24** 4 3 HL4 HL4 Control Box (see page after next) 34 2 Ref. Part Part Qty. No. Description Number 2 Diffuser Code 3= 06F*, 5F* Code 3= 20**, 24** Hi Limit- HL4, HL Heaters- See charts on following page N/S Hi Limit Switches: HL3-50 (part of heater assys.) var. N/S= Not shown on diagram. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 89

90 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heating Assemblies and Elements This chart defines the letters used in the charts below. Complete assemblies include heater elements, hardware and the control HiLimit switch (HL3-50). The Heater Assembly contains the elements less the HiLimit Control and its associated hardware. DUE TO MANY AVAILABLE SPECIAL HEATER OPTIONS, BE VERY CAREFUL SELECTING HEATER AND HEATER COMPONENTS TO ENSURE CORRECT HEATER SELECTION. Ref. Letter A B C D E F Complete Assy Heater Assy Element Only (6) (6) (6) (2) (6) (6) Ref. Letter G H I J K L Complete Assy Heater Assy Element Only (6) (6) (6) (2) (6) (6) Heater Cross Reference: 208/230/60/3 Units (Code 09= 2, 29) This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part # (Qty. = ). Heater KW- Code 34= Ref. E020** E040** E060** E080** E00** E20** E40** E60** E80** E200** E220** E240** No. Qty. 20kw 40kw 60kw 80kw 00kw 20kw 40kw 60kw 80kw 200kw 220kw 240kw 3 A B C D D D D D N/A N/A N/A N/A 32 A B C D D D D D N/A N/A N/A N/A 4 U U U U A B C D N/A N/A N/A N/A 42 N/A N/A N/A N/A A B C D N/A N/A N/A N/A 5 U U U U U U U U N/A N/A N/A N/A 52 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Heater Cross Reference: 380/50/3 & 460/60/3 Units (Code 09= 27, 28) This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part # (Qty. = ). Heater KW- Code 34= Ref. E020** E040** E060** E080** E00** E20** E40** E60** E80** E200** E220** E240** No. Qty. 20kw 40kw 60kw 80kw 00kw 20kw 40kw 60kw 80kw 200kw 220kw 240kw 3 E F G H G G H H G H H H 32 E F G H G G H H G H H H 4 U U U U F G G H G G H H 42 N/A N/A N/A N/A F G G H G G H H 5 U U U U U U U U G G G H 52 N/A N/A N/A N/A N/A N/A N/A N/A G G G H Heater Cross Reference: 575/60/3 Units (Code 09= 37) This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part # (Qty. = ). Heater KW- Code 34= Ref. E020** E040** E060** E080** E00** E20** E40** E60** E80** E200** E220** E240** No. Qty. 20kw 40kw 60kw 80kw 00kw 20kw 40kw 60kw 80kw 200kw 220kw 240kw 3 I J K L K K L L K L L L 32 I J K L K K L L K L L L 4 U U U U J K K L K K L L 42 N/A N/A N/A N/A J K K L K K L L 5 U U U U U U U U K K K L 52 N/A N/A N/A N/A N/A N/A N/A N/A K K K L Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 90

91 Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box MicroTech III (Code 2= *E, *F, *W) Diagram The above diagram shows a typical Electric Heat Control Box layout and is to be used for reference only. Specific unit configuration and components used differ depending upon options selected. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 9

92 Fuses Sch. Part Sym. Description Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box MicroTech III Units (Code 2= *E, *F, *W) Components Heater KW= 20/ Part Number Fuse-F V 230V 208V 230V 208V 230V 208V 230V 208V 230V Fuse-F Fuse-F Fuse-F Fuse-F Fuse-F Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 92

93 Fuse & Terminal Blocks Section G- BlowThru Heat Section Option 3: Electric Heat Code 04= E Electric Heat Control Box MicroTech III Units (Code 2= *E, *F, *W) Components, Continued Heater KW= 20/ Sch. Part Part Sym. Description Number FB3 Fuse Block V 230V 208V 230V 208V 230V 208V 230V 208V 230V FB32 Fuse Block FB33 Fuse Block FB4 Fuse Block FB42 Fuse Block FB43 Fuse Block PB3 Power Block TB Terminal Block Part number is for one section. The number of sections used is determined by the options installed. Contactors Heater KW= 20/ Sch. Part Part Sym. Description Number M3 Contactor Contactor M32 Contactor Contactor M33 Contactor M4 Contactor Contactor M42 Contactor Contactor M43 Contactor V 230V 208V 230V 208V 230V 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 93

94 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers and Vestibules 200, 250 MBH Furnaces Code 34= 020**, 025** 2 Heat Exchanger Burner 38 Burner Control Box 2 Gas Train 3 Ref. Part 200/250 Qty. No. Description MBH 300 Heat Exchanger Vestibule Vestibule Capillary Plate N/S Turbulator Assy N/S= Not shown on diagram. Parts detail follows this section. 2 Parts detail follows Burner section. 3 Parts detail follows Burner Control Box section. 4 Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulator Assemblies must be ordered separately. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 94

95 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers and Vestibules 320, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces Code 34= 032**, 040**, 050**, 064**, 065**, 079**, 080**, 00** Heat Exchanger Burner Burner Control Box 2 Gas Train 3 Ref. Part 320/ / / /000 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger Vestibule Vestibule N/S Turbulator N/S= Not shown on diagram. Parts detail follows this section. 2 Parts detail follows Burner section. 3 Parts detail follows Burner Control Box section. 4 Quantity varies depending upon the size of the Heat Exchanger. For 320/400 MBH order 6 pc.; for 500/640 MBH order 9 pc.; for 650/790 MBH order 2 pc.; for 800/000 MBH order 5 pc. Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulators must be ordered separately. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 95

96 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Box, Pilot Valve & Pressure Regulator Code 34= ****E*, ****R*, ****S* Diagram Burner Control Box , 250, 320 MBH Burners MBH Burners Pilot Valve/ Pressure Regulator Assy Detail 60 Burner Control Box Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 96

97 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34= ****E*, ****R*, ****S* Components Ref. Part Burner Approval Code Qty. No. Description C07= E* C07= CC, CD ETL- USA Canada 02 Burner Housing Fan Wheel Housing Wheel-.5" bore Motor-.25 HP, 5/60/ Gun Assembly 200 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace Pilot Mixer Pilot Assembly Damper Assembly Blast Tube Gasket Right Side Damper MBH Furnace MBH Furnace MBH Furnace Left Side Damper MBH Furnace MBH Furnace Slide Damper 200 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 97

98 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34= ****E*, ****R*, ****S* Components, Continued Ref. Part Burner Approval Code Qty. No. Description C07= E* C07= CC, CD ETL- USA Canada 7 Blower Gasket Burner Cover Ignition Cable Assembly 20 Glass Cover Glass Cover Support Orifice 200 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Clip Flange Bearing Air Switch Tube Pilot Burner Tube MBH Furnace MBH Furnace Compression Fitting Pilot Tube Manual Cock Valve Not Used Pressure Regulator Valve Not Used º Compression Elbow Not Used Motor Conduit Box Torsion Spring Not Used Burner Box Baffle MBH Furnace MBH Furnace Valve- Pressure Regulator Valve- Manual: MBH Valve- Solenoid: MBH N/S Flame Rod N/S Ignition Electrode Assy N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 98

99 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Diagram MBH MBH Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 99

100 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components Burner Approval Code Qty. Ref. Part C07= E* C07= CC, CD No. Description ETL- USA Canada 02 Burner Housing Fan Wheel Housing MBH Furnace MBH Furnace Wheel MBH Furnace MBH Furnace Motor MBH Furnace MBH Furnace Gun Assembly 200 MBH Furnace N/A 250 MBH Furnace N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 00

101 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part C07= E* C07= CC, CD No. Description ETL/MEA- USA Canada 0 Orifice Assembly 200 MBH Furnace N/A 250 MBH Furnace N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace , 800 MBH Furnace MBH Furnace Gasket- Blast Tube Air Box Assy Plate- Actuator Scale Gasket- Blower Panel- Burner Box Cover Ignition Wire Assy 20 Glass Cover- Burner Support- Glass Cover Grommet- Flat Box- Conduit Motor- Actuator 24V Control Arm Control Rod Crank Arm Extension- Crank Arm Bushing- Control Rod Air Linkage Air Plate- Adjustable 200 MBH Furnace N/A 250 MBH Furnace N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 0

102 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part C07= E* C07= CC, CD No. Description ETL/MEA- USA Canada 322 Air Plate- Profile 200, 250 MBH Furnaces N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Plate- Slide Damper 200, 250, 320, 400 MBH Furnaces MBH Furnace , 650 MBH Furnaces , 800, 000 MBH Furnaces Box- Air MBH Furnaces MBH Furnaces Gasket- Air Box Grommet Bearing- Sleeve Grommet MBH only N/A= Not available. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 02

103 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls (Code 34= ****E*, ****R*, ****S*) MicroTech III Controls (Code 2= *E, *F, *W) R23B IT R23A Gas Control Box FSG Detail R20A AS TB FLC Panel Detail S3 GV Detail FSG 25 Ref. Sch. Part Furnace MBH= Qty. No. Sym. Description 200/ GV Pressure Reg. Assy Valve Only Manual Cock Valve Not Used Solenoid Valve Not Used Not Used Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada S3 Toggle Switch- 4PST IT Ignition Transformer AS Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Block Terminal Block End Stop Terminal Block End Plate R20A Relay- High Amp DPDT/20V R23A Relay- High Amp DPDT/20V R23B Relay- Low Amp DPDT/20V Note that the sensor is NOT sold separately from the controller. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 03

104 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls Code 34= ****H*, ****T*, ****U* MicroTech III Controls (Code 2= *E, *F, *W) R IT R20B 62 R20A 6 AS 3 LS2 LS 34 TB 32 FLC LS, S FSG FSG Detail Ref. Sch. Part Part Qty. No. Sym. Description Number 24 Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS2 Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper R20A Relay-High Amp DPDT/20V R20B Relay- Low Amp DPDT/20V R2 Relay- Low Amp DPDT/20V Note that the sensor is NOT sold separately from the controller. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 04

105 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34= ****E*, ****R*, ****S* Gas Train Inlet Units without Pressure Regulator Valve: Code 34= ****E* 226 Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH , 500 MBH MBH Units with Pressure Regulator Valve: Code 34= ****R*, ****S* , 500, 640 MBH Furnaces , 790, 800, 000 MBH Furnaces , 250, 320 MBH Furnaces Ref. Part Pressure Regulator Qty. No. Description Code 34= ****R* Code 34= ****S* 205 Shutoff Valve MBH Pressure Regulator 200, 250, 320 MBH MBH MBH , 650 MBH , 800 MBH MBH Gas Valve 200, 250, 320 MBH , 500 MBH MBH Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 05

106 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Gas Train Inlet Units without Pressure Regulator Valve: Code 34= ****H* 226 Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH , 500 MBH MBH Units with Pressure Regulator Valve: Code 34= ****T*, ****U* 232 Back Wall of Vestibule ETL USA Units Code 07= E* (also Canada MBH ) Canada Units Code 07= C* (except MBH) Canada Units Code 07= C* Pilot Valve Detail Ref. Part Pressure Regulator Qty. No. Description Code 34= ****T* Code 34= ****U* 226 Shutoff Valve 200, 250, 320 MBH MBH MBH Pressure Regulator 200, 250, 320 MBH MBH MBH , 650 MBH , 800 MBH MBH Valve- Combination Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 06

107 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Code 34=****E*, ****R*, ****S* Gas Train Controls GV2, GV MBH Furnaces GV2 Gas Controls: 200, 250, 320 MBH Furnace Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV Junction Box Junction Box Cover Gas Pipe MBH Furnaces ETL- USA Approved (Code 07= E*) GV2 256 GV Gas Controls: MBH Furnace ETL Approved Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2, GV3 400, 500 MBH MBH Pressure Regulator 400, 500 MBH MBH Junction Box Junction Box Cover Gas Pipe 400, 500 MBH MBH MBH Furnaces Canada Approved (Code 07= C*) GV2 750 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 248 Gas Valve Body- GV2 400, 500 MBH MBH Actuator Pressure Regulator 400, 500 MBH MBH Gas Pipe 400, 500 MBH MBH MBH Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 07

108 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Gas Train Controls GV, GV2, GV4, GV5, GV MBH Furnaces GV2 254 Gas Controls: 200, 250, 320 MBH Furnace Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV N/S Junction Box N/S Junction Box Cover N/S= Not shown on diagram MBH Furnaces UL Approved (C07= EU, EF, EI) GV4 GV MBH Furnaces UL Approved (C07= EU, EF, EI) GV5 GV4 GV Gas Controls: MBH Furnace UL Approved Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV, GV MBH Gas Valve- GV,GV4,GV MBH Junction Box Junction Box Cover MBH Furnaces Canada Approved (C07= CC, CD) GV2 GV5 GV MBH Furnaces Canada Approved (C07= CC, CD) 254 GV6 GV5 GV4 GV2 246 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 246 Gas Valve Body- GV2 400, 500 MBH MBH Actuator- GV Gas Valve- GV4, GV MBH Gas Valve- GV4,GV5,GV MBH Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 08

109 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train Outlet Modulating Burners Code 34= ****E*, ****R*, ****S* 200, 250 MBH MBH Actuator & Linkage- See next page 283 Ref. Part Part Qty. No. Description Number 275 Pipe w/ Valve Mount MBH MBH MBH MBH Butterfly Valve MBH , 500 MBH MBH Shutoff Valve MBH , 500 MBH MBH MBH UL MBH Canada Actuator & Linkage- See next page Hi Turn Down Burners Code 34= ****H*, ****T*, ****U* MBH MBH 275 Ref. Part Part Qty. No. Description Number 275 Gas Valve MBH , 500 MBH MBH Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 09

110 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Damper Linkage Modulating Burners / VM Actuator Code 34= ****E*, ****R*, ****S* 297 Burner Box 295 Butterfly Valve (see previous page) 297 Burner Box 295 Butterfly Valve (see previous page) VM Actuator Switch Kit Transformer Canada Actuator Detail USA Units/Canada Units ( MBH) Canada Units ( MBH) Ref. Part Furnace MBH Qty. No. Description Actuator Motor- VM Units w/ MicroTech III Controls USA Units Canada Units Crank Arm Ball Joint Linkage Arm Crank Arm Extension Arm (Canada Units Only) Not Used Air Damper Lever Arm Gas Valve Arm Assembly part number. Motor only is p/n 35780, and Switch Kit only is p/n Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 0

111 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 200 MBH and 250 MBH Furnace Code 04= A AND Code 34= 020***, 025*** Cabinet Doors, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 649 Door Assembly Door Assembly N/S Flue Box Front Flue Box Back Flue Box Mount Sleeve Bearing Door Catch Gasket Gasket N/S Hinge N/S= Not Shown on diagram. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page

112 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 320 MBH thru 000 MBH Furnace Code 04= A AND Code 34= 032***,040***,050***,064***,065***,079***, 080***, 00*** Cabinet Doors, Gasketing, Hardware & Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly 320, 400 MBH , 640 MBH , 790 MBH , 000 MBH Inspection Door Back- Flue Box 320, 400 MBH , 640 MBH , 790 MBH , 000 MBH Angle- Flue Box 320, 400 MBH , 640 MBH , 790 MBH , 000 MBH Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket N/S Hinge N/S= Not Shown on diagram. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 2

113 Section H- BlowThru Heat Blank Access Section Notes Primary Codes that pertain: 38, Additional Codes that pertain: 34, 06 Code 38 determines all of the section characteristics. If Code 38= A the section is 22", if Code 38= B the section is 40", if Code 38= D, the section is 52". If Code 39= Y, there is no section. Code 34 determines the BlowThru Heat Section (Section G). If Code 34= BBBBBB then there is a 40" Blank spacer section. There has to be a Section G in order for there to be a Section H, therefore Code 34 cannot = YYYYYY. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heat Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. Cabinet Door Gasketing and Hardware Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Access Door Latching Assemblies, Key, & Lock (All Sections) 2 Ref. Part Part Qty. No. Description Number 0 Door Latching Assy.- LH, 55" Section var. 02 Door Latching Assy.- RH, 55" Section var. 0 Door Latching Assy.- LH, 73" Section 2422 var. 02 Door Latching Assy.- RH, 73" Section var. N/S Access Door Key var. N/S Access Door Lock var. N/S= Not Shown on diagram. 2 These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Once the door handing is determined, it is then necessary to determine the height of the section. The 55" Latching Assembly is used for unit sections 55 inches high (most sections) and the 73" assembly is used for 73" high sections (eg. Section A2 Energy Recovery [Code 20= *E]) Door Latching Assy. Left Hand Door Latching Assy. Right Hand Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 3

114 Section I- BlowThru Cooling Section Notes Primary Codes that pertain: 35, 36 Additional Codes that pertain: 06 Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 40" section. If the first three digits of Code 35= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T the first three digits of Code 35 must equal DYY. Code 36 determines the Cooling Coil's characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Cooling section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Cabinet Door Gasketing and Hardware Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 4

115 Section I- BlowThru Cooling Section Evaporator Coil, Gasket and Drain Pans Code 35= CYYP, CYYS AND Code 36= 5Z****, 4Z**** Unit Sizes 035, 042D Unit Base 4 Ref. Part Code Part Qty. No. Description 35= Number 3 Coil- refer to the following page 3 Drain Pan- Auxiliary Drain Pan- Main Galvanized CYYP Stainless Steel CYYS Gasket ft. Drain Pans Code 27= DYYP, DYYS- 40" Section- Unit Sizes 035, 042D Diagram and Components 03 Unit Base Ref. Part Drain Pan Material Code 27= Qty. No. Description DYYP- Galvanized DYYS- Stainless 03 Drain Pan For Drain Pans and components when Code 35= GYY* and/or Code 35 Digit 4= L, T, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 5

116 Section I- BlowThru Cooling Section Evaporator Coils Unit Sizes 035, 042D Typical Coil Description 4Z 08 3 D Fin Stock C= Hi-F Copper Fin (stainless casing) D= Lanced Aluminum Fin (galv. casing) Rows 3= 3 Row Coil 4= 4 Row Coil 5= 5 Row Coil 6= 6 Row Coil Fins-per-inch 08= 8 FPI 0= 0 FPI 2= 2 FPI 4= 4 FPI Coil Model Evaporator Coils are serial number specific. Please contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 6

117 Section J- Final Filter Section Notes Primary Codes that pertain: 39, 33 Additional Codes that pertain: 04, 34 Code 39 determines section characteristics. If Code 39= A, B, E, F, G, H there are filters; if C or D then there is a Blank/Empty compartment. If Code 39= Y, there is no section. Code 33 indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description. Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts. Unit Air Flow Cabinet Door Gasketing and Hardware (Applies to Filter OR Blank Section) Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Section Mounted Controls HL23 Gas Hi Limit Control: Code 04= A AND Code 39 DOES NOT= Y PC6 Clogged Filter Control: Code 39 DOES NOT= Y, C, D Gas Hi Limit Control Clogged Filter Control Control HL23 Gas Heat Hi-Limit (Firestat) Clogged Filter Pressure Switch- PC6 Supplied with PC6 Harness from Main/ Split Box Ref. Part Part Qty. No. Description Number 385 J Clamp- Antirotate Stat Support HL23 Firestat Junction Box Junction Box Cover Nipple Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 7

118 Section J- Final Filter Section Filter Frame, Filter Gaskets, Filters Code 39= A, B, E, F Access Door A Unit Base 4A Ref. Part Type of Heat Qty. No. Description C39= C04= A, E C04= W, Y 2 Filter Frame Filter Assy. w/ Gasket- 24 x 24 x 2" Standard A, B With intersept F N/A A Gasket Filter Assy. w/ Gasket- 2 x 24 x 2" Standard A, B With intersept F N/A A Gasket Gasket- Door If Code 39= G, H contact Daikin Applied with model and serial number information so that the correct filter(s) can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 8

119 Section K- Discharge Plenum Section Notes Primary Codes that pertain: 40 Additional Codes that pertain: 06,, 5, 34, 35, 36, 38, 39, 4 Code 40 determines the discharge direction. Normally RPS units have bottom discharge (Code= B*) or side discharge (Code= SY). The VAV Damper option is Code *E. Code 06, insulation and liners, influences the front panels part numbers. Code, the Disconnect Switch option, influences access doors part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Codes 34-39, the BlowThru/Final Filter section codes, and Code 4, the special Blank/Empty Section code, pertain to some of the final assembly part numbers. If Code 4=Y (no blank access compartment), then the discharge plenum end panels are painted. If a Blank/Empty Section is present, then the end panels are unpainted. Note: The Main Control Box is usually located in this section. However, the components are listed in their own section (Section N, immediately following the Condenser Section). Section Mounted Controls OAT, DAT, SD 8 8A Outside Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 8 OA Temp. Sensor A Bracket Discharge Air Temperature Sensor- DAT Main Control Box DA Opening 7A 7 Ref. Part Part Qty. No. Description Number 7 DA Temp. Sensor A Bracket Main Control Box 5 50 Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector Sampling Tube Standard Discharge Side/Top Discharge Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 9

120 Section K- Discharge Plenum Section Damper Assembly- w/ Actuator ACT5 Code 40= BE Ref. Part Part Qty. No. Description Number 30 Damper Assembly 20 x 76" w/ Act Motor Mount Damper Blade Damper Linkage Actuator Motor- ACT Damper Shaft Damper Ball Joint Damper Blade Gasket Support Retainer Bearing, sleeve flange Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 20

121 Section L- Out-of-Airstream Blank Access Section Notes Codes that pertain: 4 Additional Codes that pertain: 06 If Code 4= 2 there is a 40" Out-Of-Airstream Blank/Empty section. If Code 4= Y, there is no Out-of-Airstream Blank/Empty Section. Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Out-of-Airstream Blank Access Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For sheet metal components that make up the Out-Of-Airstream Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Cabinet Door Gasketing and Hardware (Applies to Filter AND Blank Section) Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing N/S Door Catch N/S Gasket N/S= Not Shown on diagram. This part is ordered by the foot. Order as many feet as needed. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 2

122 Section M- Condenser Section Notes Primary Codes that pertain: 09, 23, 43, 44, 45, 47 This section houses the Compressors, Condenser Coils, Inverter Compressor Control Box, Pressure Controls, and Fan Deck. Code 09 (unit voltage) affects the Compressor selection and the Compressor Contactors and Motor Protectors. Code 09 also affects the Compressor Inverter located in the Inverter Compressor Control Box. Code 43 determines if the Micro Channel Condenser Coils are coated or not, and if the unit is equipped with Coil/Vandal Guards AND/OR Sealtite conduits. Code 44 shows the type of compressor selected. For this form Code 44 always = V, W for units with Inverter Compressors. For standard OR Digital Scroll Compressor units (Code 44= R, D) refer to form Starting 04/5 ALL 06D, 03D units have been converted to use Inverter Compressors ONLY. Code 45 determines the way the compressor is mounted. Code 47 determines Condenser Fan operation. Note that ALL inverter compressor units have SpeedTrol (Low Ambient operation [Code 47= 2]) as standard. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 22

123 Section M- Condenser Section Fan Deck Diagrams Fan Layout Detail Fan # Fan # Fan # 2 Fan # 2 End of Unit End of Unit 06, 02, 026D Fan Deck Detail 020D Fan Deck Detail Fan # 2 Fan # End of Unit Fan # 2 Fan # End of Unit Fan # 2 Fan # End of Unit 025D Fan Deck Detail Fan # 2 Fan # D Fan Deck Detail Fan # 2 Fan # 22 03, 042D Fan Deck Detail CDF60 CDF50 CDF5 CDF MOTOR GND WIRE Standard Fan Deck Unit Sizes D shown Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 23

124 Section M- Condenser Section Standard Condenser Fan, Fan Motor, Motor Mount, Fan Deck Panel Code 47= Ref. Part Part Unit Size No. Description Number Panel- Blank N/A 7 N/A Top Panel Condenser Motor 208/230/ Condenser Motor Condenser Fan Motor Mount Condenser Fan Prop Condenser Fan Guard This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of two per Motor. 2 Note that the same p/n and quantity is also used for Quiet Fan Assemblies (Code 47= 4). Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 24

125 Section M- Condenser Section Quiet Fan Assembly Code 47= 4 Unit Size Ref. Part Part No. Description Number Quiet Fan Assembly, 2 208V V Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor Mount, and Fan Top Panel are NOT available separately. 2 For Top Panel Blank Panels (Bub # 55) see the previous page. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 25

126 Section M- Condenser Section Compressors Circuit # Compressors Circuit # Unit Size /230V 208/230V Ref. Part No. Number (T) (T) (T) (T) (T) (T) (T)= Tandem compressor assembly. 208/230V 208/230V 208/230V 208/230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 26

127 Section M- Condenser Section Compressors Circuit #2, Compressor Crankcase Heaters Compressors Circuit #2 Unit Size /230V 208/230V Ref. Part No. Number /230V 208/230V 208/230V 208/230V Compressor Crankcase Heaters Part Number Unit Unit Compressor Compressor Compressor Compressor Size Voltage All N/A N/A N/A 020, 02 All N/A N/A N/A 025, 026 All N/A N/A N/A 03 All N/A N/A N/A 035 All N/A N/A 042 All N/A N/A N/A= Not available. One Crankcase heater is used per compressor. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 27

128 Section M- Condenser Section Inverter Compressor Components A Oil Injection Solenoid Optical Oil Sensor 27 Discharge Temp. Sensor Ref. Part Part Qty. No. Description Number 25 Solenoid, Oil Injection, 24V Oil Sensor, Optical A Sight Glass/Prism, Optical Oil Sensor Sensor, Compressor Discharge Temperature Connector, Rectangular Fitting, Male The Sight Glass/Prism comes assembled with Optical Oil Sensor p/n (Ref # 26). If ONLY the Sight Glass/Prism is required use p/n Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 28

129 Section M- Condenser Section Compressor Mounting Compressor Mounting Circuit # Unit Sizes Unit Sizes 035, Ref. Unit Size Part Part Qty. No. Description Number 02 06, 025, 026 Mounting Kit , 02 Mounting Kit Mounting Kit , 042 Grommet , 042 Sleeve , 020, , 026, 03 Screw , 042 Screw , 020, , 026, 03 Washer , 042 Washer , 020, , 026, 03 Washer, Locking , 042 Washer, Locking Compressor Mounting Circuit #2 02 Ref. Unit Size Part Part Qty. No. Description Number 02 ALL Mounting Kit Note that the inverter compressors located in Circuit #2 come with mounting hardware. If a replacement mount is required contact Daikin Applied with model and serial number information so that the correct Mounting Kit can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 29

130 Section M- Condenser Section Condenser Coils & Coil Guards Coil Guards (Code 43= *G, B) Ref. Part Part Unit Size No. Description Number Condenser Coils Code 43= M* N/S 27" x 48" " x 93" Condenser Coils Code 43= T* N/S 27" x 48" " x 93" Condenser Coils, Coated Code 43= P* N/S 27" x 48" " x 93" Condenser Coils, Coated Code 43= U* N/S 27" x 48" " x 93" Coil Guards 0 Side Grille End Grille End Grille End Filler Panel End Filler Panel Side Grille, Pressure Controls Side Grille, Pressure Controls Pressure Control Box Filler Panel Side Grille, VFD Side Grille, VFD Control Box Filler Panel, VFD 230V Control Box Filler Panel, VFD N/S= Not shown on Diagram. Note that starting 04/5 ALL 06D units have been converted to use Inverter Compressors ONLY. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 30

131 Section M- Condenser Section Condenser Coils & Coil Guards, Continued Coil Guards (Code 43= *G, B) Ref. Part Part Unit Size No. Description Number Condenser Coils Code 43= M* N/S 27" x 7" " x 93" Condenser Coils Code 43= T* N/S 27" x 7" " x 93" Condenser Coils, Coated Code 43= P* N/S 27" x 7" " x 93" Condenser Coils, Coated Code 43= U* N/S 27" x 7" " x 93" Coil Guards 0 Side Grille End Grille End Filler Panel Side Grille, Pressure Controls Side Grille, Pressure Controls Pressure Control Box Filler Panel Side Grille, VFD Side Grille, VFD Control Box Filler Panel, VFD 230V N/S= Not shown on Diagram. Note that starting 04/5 ALL 03D units have been converted to use Inverter Compressors ONLY. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 3

132 Section M- Condenser Section Pressure Controls Box SPTRL PT HP A 235 LP SPTRL A 235 PT2 HP LP Ref. Sch. Part Part Qty. No. Sym. Description Number 220 TB35 Terminal Block Assy TB36 Terminal Block Assy N/S TB37 Terminal Block Assy , 234 LP, 2 Switch- Low Pressure HP, 2 Switch- High Pressure SPTRL Switch- SpeedTrol Pressure A - Harness, Pressure Transducer Valve Core Valve Cap PT, 2 Pressure Transducer , 244 VFD, 2 Size D 208/230V , 244 VFD, 2 Size D 208/230V LRB, 2B Line Reactor- SpeedTrol () N/S= Not shown on diagram. For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 32

133 Section M- Condenser Section Factory Supplied Powered Receptacle- Code 23= ***F* DS6, TB7, T6, FU6A, B, C 02 0 TB7 DS6 Main Control Box Pressure Controls Box Voltage Ref. Sch. Part Part No. Sym. Description Number 0 DS6 Fuse Holder/Circuit Protector 2P, 30A, 600V FU6A, B Fuse 20A/600V Fuse 0A/600V Fuse 8A/600V TB7 Terminal, 2 x 2 Green Terminal Block End Plate Terminal, 2 x 2 Grey Terminal Block End Stop Grey T6 Transformer 2KVA Transformer 2KVA Transformer 2KVA Terminal Cover Kit FU6C Fuse 20A/600V V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 33

134 Section M- Condenser Section Inverter Compressor Control Box Local Control Panel TB4 Detail Ref. Sch. Part Part Qty. No. Sym. Description Number 020 TB4 Terminal Block Assy End Stop Terminals Socket, Relay R38, 39 Relay, 20V R40 Relay, 24V End Plate Heater, 20V Tstat, Heater VFD/AFD2 Inverter, Compressor 4 Unit Size D 208/230V VFD/AFD2 Inverter, Compressor 4 Unit Size D 208/230V Local Control Panel, Inverter Muffin Fan Louver Kit Filter Kit Cylinder Lock The Terminal Block Assembly includes End Stops, Terminals, Relays, Relay Sockets, and an End Plate. Refer to the detail drawing to identify individual parts of this assembly. 2 Part ONLY of Terminal Block Assembly p/n Contact Daikin Applied with model and serial number information so that the correct inverter can be identified. 4 Note that the Local Control Panel (Ref # 329) is NOT supplied with the inverter. It must be ordered SEPARATELY if needed. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 34

135 Section N- Main Control Box Notes Primary Codes that pertain: 2, 09,, 3, 4, 5, 6, 7, 8, 23, 68 Additional Codes that pertain: 04, 9, 20, 22, 27, 32, 34, 35, 40 The Main Control Box is normally mounted in the Discharge Plenum Section (Section K) and is comprised of three primary parts The Dead front Door with Keypad, the Control Panel, and the Power Panel. Code 2 determines which type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, or None) and whether the unit uses Discharge Temperature, Space Control, or Zone control. There is an MCB and separate Expansion Boards (Condenser, Electric Heat, Energy Recovery) in the control panel. Code 9 determines unit voltage and affects the Transformers, Fan Overloads/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Terminal Block or a through-the-door Disconnect Switch. Code 3 determines the presence of Duct and/or Space Sensors. Codes 4 and 5 determine the Supply AND Return fan Inverter specifications. Code 6 determines the presence of Smoke Detectors. Code 7 AND/OR 23 determine miscellaneous electrical options including whether the unit has a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc. Code 68 (Mid 202 & Later) indicates the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at "0 SCCR" (Code 68= 0, YY, OR no entry for 54 Code units). An entry with any other rating (Eg.: Code 68= 65) may change disconnect switches, circuit breakers, and miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 8 indicates whether a unit has a Remote Keypad Display AND/OR a unit mounted Receptacle. Codes 9, 20, 22 are return air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc, have an impact on Contactors, Motor Protectors, Fuses, and Duct Sensors. Code 27 determines the DrawThru section, and can impact the Cooling Circuit Relays. Code 32 determines horsepower for the Supply Fan Motor which, like the Return Air Motor will affect Contactors, Fuses, Motor Protectors, etc. Codes 04, 34, and 35 determine the BlowThru section, and the heat type, which impact Transformers, Heat Circuit Relays, and Cooling Circuit Relays. Code 40 determines if there is a VAV Damper and related Control Relay. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 35

136 Section N- Main Control Box Control Panel- MicroTech III Control Box Component Label Diagram GOI Number: H R02 MB= Main Box; BB= Bypass Box; EB= Electric Heat Box; GB= Gas Box; PB= Prop Exhaust Box; Location Device ID McQuay Part # Description GB AS Ctrl-press air switch gas burner GB AS Conduit fitting nipple GB FLC Control Temp Fan Limit Gas Heat GB FSG Ctrl-temp flame safegrd base GB FSG Ctrl-temp Flame Safegrd Control GB FSG Ctrl-temp flame safegrd amplifier GB FSG Ctrl-temp flame safegrd timer 90 GB IT Transformer Ignition GB LS Limit switch GB LS Limit switch GB R20A DPDT Relay 5A 20VAC GB R20A Mounting Adapter 2P Relay to Dinra GB S Switch Toggle 4PST 25V MB BNMS Communication Card, BACnet-MSTP, MT MB DHL Pressure Switch SPDT MB DS Circuit Breaker Molded Case Switch MB DS lug kit, 3 pcs with power control t MB DS Connector -4 quick connect tab MB DS lug kit, 3 pcs, T3 Frame, 225A MB DS SCREW, PANHEAD AB-type, #8-8 X 3" MB DS Circuit Breaker Operating Mechanism MB DS HANDLE, PISTOL, ABB DISCONNECT, RED MB DS Fuse holder, Circuit Protector, 2 P MB DS Fuse 0A Rejection Type MB EXP-B Extension I-O 2 5 Points MB EXP-B Connector for extension I-O - Direc MB EXP-C Extension I-O 2 5 Points MB EXP-C Connector for extension I-O - Direc MB F Fuse 7A Rejection Type MB FA Fuse 8A Rejection Type MB FB Fuse 8A Rejection Type MB FC Fuse 5A Midget Non-Rejection Ty MB F Fuse 7A Rejection Type MB F Fuse 5A Midget Non-Rejection Ty MB FB Fuse 80A 600V Class J Fast Actin MB FB Fuse, 30A 600V Class CC Type T Fast MB FB2M Fuse, 70A, 600V, Class J Fast Actin MB M Contactor IEC 32A 20VAC Coil Sprin MB M MMP to Contactor Link Module Screw MB M MMP to Contactor Spacer Size S0 MB M SCREW, PANHEAD B-type, #8 X " MB M Contactor IEC 32A 20VAC Coil Sprin MB M MMP to Contactor Link Module Screw MB M MMP to Contactor Spacer Size S0 MB M SCREW, PANHEAD B-type, #8 X " MB MCB Base Controller with IP and Inbuilt MB MMP MMP Class 0 Size S0 7 to 22A Scre MB MMP MMP Auxiliary Contact Sizes S00 and MB MMP MMP Bus Bar 2 Position No Lateral A MB MMP MMP Bus Bar Type E Feeder Terminal MB MMP MMP Class 0 Size S0 7 to 22A Scre MB MMP MMP Auxiliary Contact Sizes S00 and MB OAER DPDT Relay 0A 24VAC MB OAER Relay Socket DPDT MB PB Distribution Power Terminal Brd 7 MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 24VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 24VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R PDT Relay 0A 20VAC MB R Relay Socket 3PDT MB REC Receptacle Ground Fault Interrupter MB RES RESISTOR 500 Ohm -8 Watt % Pr MB RES RESISTOR 000 Ohm -8 Watt % Pr MB RES RESISTOR 500 Ohm -8 Watt % Pr MB S Switch Toggle DPST 25V MB S Switch Toggle 2position ON-ON S MB SPS SENSOR, AIR PRESSURE/VELOCITY, DIN MB T MICRON Transformer, CPT, W/ FB,50 MB T Cover, Terminals, Micron 6-terminal MB T Cover, Fuseholder, Micron Type 2 Tr MB T Washer, /4" Flat MB T Washer, Split Lock MB T Transformers 75va 20V-24Vac MB T Transformers 75va 20V-24Vac This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 36

137 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code 2= *E, *F, *W) Diagram TB COM MCB See Power Panel See Power Panel See Power Panel The above diagram shows a typical Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 37

138 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code 2= *E, *F, *W) Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- 2 Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad/Interface Display Expansion Modules EXP A Expansion Module- Condenser/ Energy Recovery EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- 2 Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Hot Gas Reheat RHB, 2 Interface Board, Modulating Hot Gas Reheat Code 54= BM Communication Cards COM Bacnet- MSTP Code 2= BE, BF, BW Bacnet- IP Code 2= EE, EF, EW LonWorks- Discharge Code 2= LE, LW LonWorks- Constant Volume Code 2= LF Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES2 Resistor- Refrigeration Circuit #2 000 OHM RES3 Resistor- Freezestat FS 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS2, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW or No Heat with no UV Lights SPST/20A Electric, Steam, HW or No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A Transformers T2 Transformer- Control 20-24V T3 Transformer- Control 20-24V T7 Transformer- Hot Gas Reheat 20-24V Receptacle REC Receptacle Duct Hi Limit and Duct Static Pressure Sensors DHL Duct Hi Limit Switch SPS, 2 Pressure Transducer- Duct Sensor Pressure Transducer- Space Sensor Not Shown on diagram. 2 Quantity varies depending upon unit options selected. 3 SPS Duct Sensor Code 3=, 2, 3. SPS2 Duct Sensor Code 3= 2. SPS2 Space Sensor Code 3= 3, 4. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 38

139 C F Sch. Part Part Qty. Sym. Description Number Relays R2 Relay- Condenser Fan R4 Relay- Condenser Fan R20 Relay- Heat R25 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,2,3,5,6, R63 Section N- Main Control Box Control Panel MicroTech III Units with Controller (Code 2= *E, *F, *W) Components, Continued Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4= 2, 5, 7 Vars. Code 3=, 2, 3, 4, Y R8 Relay- Smoke 4P/6A/24V R82 Relay- Smoke 4P/6A/24V R83 Relay- Smoke 4P/6A/24V R84 Relay- Smoke 4P/6A/24V R85 Relay- Smoke 4P/6A/24V R86 Relay- Smoke 4P/6A/24V R87 Relay- Smoke 4P/6A/24V R88 Relay- Smoke 4P/6A/24V Time Delay TD20 Time Delay 20 Second Terminal Block TB Terminal Block Sensors 3 ZNT Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj. 2, DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only (Code 2= *F). 3 Not Shown on diagram. 4 Digital Room Sensor p/n is the preferred option. The other Zone Temperature Sensors are available as options. For positive p/n identification, refer to the drawings below. ZNT Sensor ZNT Sensor 3770 ZNT Sensor 3780 Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 39

140 Section N- Main Control Box Power Panel Diagram See Control Panel See Control Panel See Control Panel PL - PL43 Plugs The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 40

141 Section N- Main Control Box Power Panel Terminal Blocks, T Transformer, & Fuses Sch. Part Part Voltage Sym. Description Number 208V 230V Terminal Blocks TB2, 3, 4, 7 Terminal Block Transformer- Main 3 T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= FC Fuse- T Transformer Fuse- T Transformer Fuse- T Transformer Varies depending on unit options. Part number is for one individual section. Ground block is p/n Jumpers are p/n (TBA:5), (TBB:4), (TBC:20, TBD:25 & TBE:30). 2 Varies depending on unit options. Part number is for one individual section. Ground block is p/n All T Transformers use Fuse Puller Kit p/n & Cover Kit p/n Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; = Non- Gas Heat Units with no UV lights. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 4

142 Section N- Main Control Box Power Panel Fuses, Ground Fault Protection, Phase Protection (PVM, 2), Power Supply, & Power Blocks Sch. Part Part Voltage Sym. Description Number 208V 230V Fuses F2,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F2 Fuse VA transformer F3 Fuse- Blower Motor Code 04= A F5 Fuse- UV Lights Code 7 (2nd digit)= Ground Fault Code 7 [2nd digit]= G, B, C, D, K GFR Ground Fault Relay- SPDT GFS Ground Fault Sensor Phase Voltage Code 7 [2nd digit]= P, A, C, D, H, J, K PVM, 2 Phase Voltage Monitor (2/6 & Earlier) Phase Voltage Monitor (2/6 & Earlier) Phase Voltage Monitor (/7 & Later) Phase Voltage Monitor (/7 & Later) Socket, PVM (/7 & Later) Power Blocks PB Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 255A Lug- 255A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 620A Cover- 620A Block Lug- 620A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 208/230V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Code 04= E 20, 40 KW Electric Heat , 80, 00, 20 KW Electric Heat , 80, 00, 20 KW Electric Heat , 60, 80, 200, 220, 240 KW Electric Heat PB0 Power Block- Supply Fan Code 5= F PB20 Power Block- Return Fan Code 5= F Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 42

143 Section N- Main Control Box Power Panel Disconnect Switches & Plugs Sch. Part Part Voltage Sym. Description Number 208V 230V Disconnect Switch DS Disconnect Switch- Main Switch- 00A Handle Shaft Switch- 50A Handle Mechanism Shaft Lugs Switch- 250A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Switch- 800A Handle Mechanism Shaft Lugs Switch- 000A Handle Mechanism Shaft Lugs Plugs Pin Plug varies varies varies varies 6 6 Pin Plug varies varies varies varies 7 2 Pin Plug varies varies varies varies 8 3 Pin Cap Kit varies varies varies varies 9 6 Pin Cap Kit varies varies varies varies 0 9 Pin Cap Kit varies varies varies varies 5 Pin Cap Kit varies varies varies varies Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 2 This Shaft is 4.25 OAL and is designed to be cut to length in the field. 3 This Shaft is 7.2 (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. 5 Used for PL, PL, 2, PL3, PL4, PL5, PL6, PL22,PL23, PL24, PL37, PL38. 6 Used with Strain Relief (p/n ) & 6 pin Cap Kit (p/n ). Used for PL20, PL2. 7 Used for PL, PL2, PL25, PL26, PL27, PL28, PL29, PL30 (PL & 2 also use Strain Relief p/n & Cap Kit p/n ). 8 Used for PL6, PL7, PL3, PL32, PL33, PL34, PL39, PL40, PL4, PL42. 9 Used for PL9, PL0. 0 Used for PL8, PL9, PL35, PL36, PL43. Used for PL7, PL8. 2 All possible Plugs used are listed. Check actual unit to verify which Plug is required. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 43

144 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Return MMP20 & M20 Fan Contactor Diagrams Phase Barrier Front Mtd. Aux. Contact 2 3E MMP 3 Phase Barrier Front Mtd. Aux. Contact 2 3E MMP 3 MMP 3 2 Link 3B Contactor Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact 3B Link Contactor MMP0 & M0 Link Detail - 2 HP Motors- All Voltages 3, 5 HP Motors- 460/ 7.5 HP Motors- MMP0 & M0 Link Detail 3, 5 HP Motors- 208/230V 7.5 HP Motors- 208/230/ 0 HP Motors- All Voltages 5, 20 HP Motors- MMP0 & M0 Link Detail 5 HP Motors- 208/230/ 20 HP Motors- 25 HP Motor- 460/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier 3E Front Mtd. Aux. Contact 2 MMP 3 Link 3B Contactor MMP0 & M0 Link Detail 20, 25 HP Motors- 208/230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 44

145 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components HP Motor- Code 22 OR 32= E*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 4A Fuse- Supply OR Return Fan 2A Fuse Cover/Puller- Supply OR Return Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 2 pc. PER Fuse. 208V 230V.5 HP Motor- Code 22 OR 32= F*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 5A FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 8A Fuse- Supply OR Return Fan 7A Fuse- Supply OR Return Fan 3A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 4 pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 45

146 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 2 HP Motor- Code 22 OR 32= G*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 5A FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 9A Fuse- Supply OR Return Fan 4A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 2 pc. PER Fuse. 208V 230V 3 HP Motor- Code 22 OR 32= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 5A FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 7A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 4 pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 46

147 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code 22 OR 32= J*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 5A FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 25A Fuse- Supply OR Return Fan 20A Fuse- Supply OR Return Fan 0A Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 2 pc. PER Fuse. 208V 230V 7.5 HP Motor- Code 22 OR 32= K*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 5A FB0, 20 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 35A Fuse- Supply OR Return Fan 5A Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 4 pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 47

148 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code 22 OR 32= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 5A FB0, 20 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 50A Fuse- Supply OR Return Fan 45A Fuse- Supply OR Return Fan 20A Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 2 pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 48

149 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code 22 OR 32= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 20A FB0, 20 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 70A Fuse- Supply OR Return Fan 60A Fuse- Supply OR Return Fan 30A Fuse Cover- Supply OR Return Fan Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 2 pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 49

150 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 20 HP Motor- Code 22 OR 32= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link Link E Phase Barrier Phase Barrier N/S VFD0, 20 VFD- Supply OR Return Fan N/S CB0, 20 Circuit Breaker- Supply OR Return Fan 70A Circuit Breaker- Supply OR Return Fan 60A Circuit Breaker- Supply OR Return Fan 30A FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 40A Fuse Cover- Supply OR Return Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 208V 230V 25 HP Motor- Code 32= P*Y 3 Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply Fan 80A Contactor- Supply Fan 40A Contactor- Supply Fan 32A Aux. Contact- NC OR NO MMP0, 20 MMP- Supply Fan 57-75A MMP- Supply Fan 45-63A MMP- Supply Fan 22-32A B Link Link Link E Phase Barrier N/S VFD0, 20 VFD- Supply Fan N/S CB0, 20 Circuit Breaker- Supply Fan 90A Circuit Breaker- Supply Fan 80A Circuit Breaker- Supply Fan 40A FB0, 20 Fuseblock- Supply Fan Fuse- Supply Fan 50A Fuse Cover- Supply Fan N/S= Not Shown on Diagram. 2 Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 3 A 25HP Supply Fan Motor is only available when Code 3= 24**. A 25HP Motor is not available for Return Fan applications. 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 50

151 Section N- Main Control Box Power Panel Compressor Motor Protector MMP, 3 and Contactor M, 3 Diagrams Phase Barrier Front Mtd. Aux. Contact 2 3E MMP 3 Side Mtd. Aux. Contact (RPS) 4 3 MMP Link 3B 3A Spacer Contactor 2 Front Mtd. Aux. Contact 3B Link Contactor Compressor Link Detail 06D: 208/460/ 025, 026D: 035, 042D: Compressor Link Detail 06D: 230V 020, 02D: 208/230/ 025, 026D: 030, 03D: 460/ 035, 042D: 208/230/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier Side Mtd. Aux. Contact (RPS) 4 3E MMP 3 Front Mtd. Aux. Contact 2 Link 3B Contactor Compressor Link Detail 025, 026D: 208/230V 030, 03D: 208/230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 5

152 Section N- Main Control Box Power Panel Compressor Motor Protector MMP, Contactor M & Fusing Unit Size 06D Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors M Contactor- Circuit # Contactor- Circuit # Contactor- Circuit # Contactor- Circuit # Compressor MMP's & Parts 2 Front Mtd. Aux. Interlock- NO OR NC Front Mtd. Aux. Interlock- NO OR NC MMP Motor Protector- Circuit # Motor Protector- Circuit # Motor Protector- Circuit # Motor Protector- Circuit # A Spacer B Link Link E Phase Barrier Side Mtd. Aux. Interlock- NO OR NC Inverter Compressor Fuseblocks & Fuses FB2M Fuseblock Fuse Cover Fuseblock Fuse Cover Fuseblock - Fuse Cover - Fuses 80A Fuses 40A Fuses 3 3 Contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. 208V V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 52

153 Section N- Main Control Box Power Panel Compressor Motor Protector MMP, Contactor M & Fusing Unit Sizes D Unit Size 020, , Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors M Contactor 65A Contactor 40A Contactor 32A Contactor 25A Contactor 6A Compressor MMP's & Parts 2 M Front Mtd. Aux. Contact Front Mtd. Aux. Contact MMP Motor Protector 45-63A Motor Protector 36-45A Motor Protector 28-40A Motor Protector 22-32A Motor Protector 8-25A Motor Protector 7-22A Motor Protector 4-20A Motor Protector 4-20A Motor Protector - 6A Motor Protector 7-0A A M Spacer B M Link Link Link E M Phase Barrier Phase Barrier M Side Mtd. Aux Inv. Cmpr. Fuseblocks & Fuses FB2M Fuseblock Fuse Cover Fuseblock Fuse Cover Fuseblock - Fuse Cover Fuses 80A Fuses 40A Fuses Contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. 208V 230V 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 53

154 Section N- Main Control Box Power Panel Compressor MMP, 3, Contactor M, 3 & Fusing Unit Sizes 035, 042D Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors Unit Size M, 3 Contactor 40A Contactor 25A Contactor 25A Comp. MMP's & Parts 2 M, 3 Front Mtd. Aux. Contact Front Mtd. Aux. Contact MMP, 3 Motor Protector 28-40A Motor Protector 4-20A Motor Protector - 6A Motor Protector 7-0A A M, 3 Spacer B M, 3 Link Link M, 3 Side Mtd. Aux N/S Busbar Busbar N/S Busbar Top Feed Busbar Top Feed Inv. Cmpr. Fuseblocks & Fuses FB2M Fuseblock Fuse Cover Fuseblock Fuse Cover Fuseblock - Fuse Cover Fuses 00A Fuses 60A Fuses N/S= Not Shown on Diagram. Contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 54

155 Section N- Main Control Box Power Panel SpeedTrol Condenser Fan Fusing: Code 47= 2, 4 Puller 9B Fuse 9A 9 Fuse Block SpeedTrol Fusing Detail F, F2 & M2, M22 Unit Size Ref. Sch. Part Part No. Sym Description Number SpeedTrol AFD Fusing 9 FB, 2 Fuse Block A F, 2 Fuse Code 47= 2 208V 7A V 5A V A A A F, 2 Fuse Code 47= B - Fuse Cover/Puller Contact Daikin Applied with model and serial number information so that the correct fuse can be identified. Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 55

156 Section N- Main Control Box Power Panel Energy Recovery Wheel Contactors, MMPs, & Fusing Phase Barrier 8E MMP 8 Fuse Block 9 Link 7B 7 Contactor Cover 9B 9A Fuse MMP & Contactor Detail ERW Fusing Detail Heat Recovery Control Type 00% OA Low Flow 00% OA HI Flow Economizer Code 20= E Code 20= 2E Code 20= 3E Ref. Sch. Part Part No. Sym. Description Number Heat Wheel Contactor 7 M60 Contactor 7A M6 Contactor 7A B Link- MMP Heat Wheel MMP 8 MMP60 Motor Protector Motor Protector Motor Protector Motor Protector MMP6 Motor Protector Motor Protector Motor Protector Motor Protector E Phase Barrier N/S Busbar N/S Busbar Top Feed ERW Fusing 2 9 FB60,6 Fuse Block A F60, 6 Fuse 0A Fuse 9A Fuse 5A Fuse 4A Fuse 3A B Fuse Cover/Puller N/S CB60, 6 Circuit Breaker 5A N/S OL6 Overload 0.7- A N/S= Not shown on diagram. For Heat Wheel Inverter (VFD60) p/ns, refer to the "VFD60 Frost Protection Inverter (Code 24= F)" page in Section A2. 2 Fuse components for the Heat Wheel are located in the Power Panel. 208V 230V 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 56

157 Section N- Main Control Box Intelligent Equipment: Code 23= ****A, ****L (Mid 202 & Later) Intelligent Equipment from Daikin Applied (Code 23= ****A) is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation. A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality IE Express (Code 23= ****L) connects directly to your Daikin unit and offers a low cost, easy to install, entrylevel solution to cloud equipment controls for those who don t need the Energy Management Module (EMM) found in the Intelligent Equipment offering. Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply. Click on this link to access the RPL for Intelligent Equipment: Rooftop Inv. Cmpr. Units: RPS Vintage D Revision J 05/8 RPL / Page 57

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W Replacement Parts List No. 70005300 Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT 045-074 Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor,

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70003700 Revision U 07/2 Roofpak Applied Rooftop Units RPS, RDT, RFS, RCS Sizes 045-079 Tons Vintage D R40a To find your Daikin McQuay Parts distributor, call -800-377-2787 or

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019 Replacement Parts List No. 700052600 Revision G 0/209 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017 Replacement Parts List No. 110502600 Revision I 09/2017 McQuay Superpak Applied Rooftop Units RRS, RSS 018-071 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

RoofPak Applied Rooftop Systems Air Handler

RoofPak Applied Rooftop Systems Air Handler Installation and Maintenance Manual IM 987 RoofPak Applied Rooftop Systems Air Handler Group: Applied Air Systems Part Number: IM 987 Date: May 009 RAH 047C - 077C,,000 to 50,000 cfm RDS 800C - 80C, 4000

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information