Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Size: px
Start display at page:

Download "Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1"

Transcription

1 Replacement Parts List No Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History Nomenclature Serial Number... 5 Model Number Electrical Legend... 8 Unit Sections... 9 Return Air Configurations... 9 Blower Fan Assembly Refrigeration Circuit Diagrams...11 Components Hot Gas Reheat Water Flow Regulator Control Box- Microtech III Controls Diagrams Components MTIII Control Board Label Location Field Installed Accessories Critical Parts List... CPL1 WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 2

3 Parts List Revision History Rev. Date Description NEW 8/12 NEW A 10/12 Page 4- Add Code 13 Sound Packages A= Premium. Page 5- Code 23 add P= Controls for Electric Heat single 24V signal(field installed Duct Heater by Others) Page 10- Add Sound Blanket p/ns & Page 10- Change condensate pan p/ns to SERVSub p/ns. Change condensate pan p/ns to SERVSub p/ns. Delete all base pans. Page 12- Delete Series 2 from p/n & descriptions. Page 17- Add Electric Duct Heater Kit. CPL1- Delete Series 2 from p/n & descriptions. B 12/12 Page 10- Remove Sound Blanket p/ns and C 2/13 Page 11- Change Condenser to CO-AX Condenser and Cupro-Nickel to Copper. Change CO-AX Coil p/n to D 2/13 Page 12- Change MTIII control board p/n to Change I/O expansion board assy p/n to Change LonWorks com card p/n to Change BACnet com card p/n to Remove footnote. CPL1- Change MTIII control board p/n to ; I/O exp. board p/n to ; LonWorks card p/n to and BACnet card p/n to E 3/13 Page 9- Add 460V table for ECM motors. Change ECM motors from phantom p/ns to Program p/ns. Page 13- Remove Wire Harness Assy p/n from MTIII module kits. Page 14- Add Actuator p/n to 3-Way Valves rename Waterside Economizer. Rename 2-Way Valves to Motorized Valves. Page 15- Remove Boilerless System Kits and move sensors to Thermostats & Sensors. CPL1- Add 460V to ECM motors. F 10/13 Rebrand Daikin. Page 9- Add ECM motor size 015 p/n Page 12- Add LT sensors p/n CPL1- Add ECM motor size 015 p/n Change Reversing Valve. Add LT sensor. G 2/14 Page 12- Change H6 Connector p/n EGA9164 to H 10/14 Numerous drawing & p/n changes done. Separate vertical & horizontal units. Pages 4-6 Change to horizontal model configeration. Code changes to C03, C10, C43 & C44. Page 8- Delete Typical Refrigeration Cycle and add Unit Sections and Return Air Configerations. Page 9- Delete 460V ECM not used in size Ref #370 Change Qty from 1 to 3. Page 11- Change overload protector p/n to Change adapter p/n to Change fusible plug assy p/n to Page 12- Add Hot Gas Reheat and Water Flow Control. Page 14- Delete the control box BACnet & LonWorks p/ns & Page 15- Add footnote for field conversion kits LonWorks p/n & BACnet p/n Pages 16- Add Loop Pumps. Numerous hoses were added. CPL1- Delete BACnet & LonWorks p/ns & Delete 460V ECM. I 4/15 Page 9- Delete ECM p/ns and add nameplate diagram and footnote1. Page 14- Delete control board p/n and add footnte *. Change Ref# 315 Change I/O Exp Board p/n to CPL1- Delete control board and ECM p/ns. J 11/15 Rebrand Daikin. Page 14- Ref# 229 Add MTIII p/n Change Exp. Board p/n to Delete Disc. Switchs p/ns , , & Add handle p/n Add Relay p/n Delete Contactor p/n Add footnote for MTIII Controls Label Location. Page 15- Add MTIII Controls Label Location table and footnote. CPL1- Add MTIII p/n Delete Refrigeration Circuit. K 05/17 Page 14- Add yellow plug p/n ; white plug p/n and bridge connector p/n L CPL1- Update revision. 06/17 Page 4- Model Number changed to table format and SLP added to Serial Number. Page 17- Add WSE Coils, RH p/ns (until 03/15) & (03/15 & later) Add WSE Coils, LH p/ns (until 03/15) & (03/15 & later) CPL1- Update revision. M 12/17 Pages Add Ref # 240 & 238 relay p/ns & Page 18- Add 3 Ft. hoses. Page 19- Add boilerless system kit p/ns & CPL1- Update revision. Daikin Applied, Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 3

4 Rev. Date Description N Parts List Revision History Continued 10/18 Page 4- Add Parts List Revision History page. Page 8- Electrical Legend updated. Page 12 Change Rev Valve size 015 p/n to and 019 p/n to Page 13- Add page. Change drain pan p/n to (LH) & (RH). Page 16- Add footnote for disconnect switch and delete unit size. Change size for capacitor Ref# 68 & 72. Delete Connector Bridge p/n , plug p/ns & Pages Numerous changes to Field Installed Accessories. Change filters from kit p/ns to single p/ns. Change WSE 3-way valve, LH p/n to CPL1- Update revision. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 4

5 Nomenclature Serial Number AUB U Plant Identification Abbreviation AUB = Auburn SLP = San Luis Potosi U= Unit Serial Number (build sequence) Week of Manufacture Year of Manufacture 12= = 2013 etc. Model Number WGSH 015 B 1 E WL R S 4 Y Y Y C S YYY B 2 A Y Y Y Y Code YY B D Y Y Y YYY Y YYY S Y Y B S Y A Y A T Y C Y YY Code Y Y 2 T Y S A L K Y Y Y Y YY Y Y A Y Y Y Y A A Y Code C Y Y YY FF ST ST YY YYY Y C Y Y YY 1 Code Code 01: Unit Type W= Water Source Heat Pump Code 02: Model Type GS= High Efficiency, Single Stage Code 03: Configuration H= Horizontal Code 04: Unit Size 015= BtuH Nominal Cooling 019= BtuH Nominal Cooling Code 05: Unit Control B= MicroTech III Unit Controller Code 06: Design Series (Vintage) 1= Design 1 Code 07: Voltage E= /60/1 J= 265/60/1 Code 08: Range for Entering Water/Glycol Temp. WL= Water Loop GL= Ground Loop Code 09: Return Air Location L= Left-Hand Return Air & Right-Hand Piping R= Right-Hand Return Air & Right-Hand Piping Code 10: Discharge Air Location E= End S= Straight Code 11: Fan Motor 4= ECM Constant CFM Code 12: Dehumidification Option B= Hot Gas Reheat Smart Dehumidification C= Simplified Dehumidification (Lower CFM no HGRH or no Humidistat) D= Humidistat Controlled Dehumidification (No HGRH) E= Humidistat only Code 13: Sound Packages A= Premium Code 14: IAQ Packages (Indoor Air Quality) Code 15: Coaxial Heat Exchanger Construction C= Copper Inner Tube- Steel Outer Tube S= Cupro-Nickel Inner Tube- Steel Outer Tube Code 16: Primary Air Coil Options S= Standard E= E-Coated Codes 17-18: Always YYY Code 19: Communication Module B= BACnet F= BACnet - WSHP System L= LonWorks Code 20: Filter Rack 2= 4-Sided, 2" w/duct Collar & Door 3= 4-Sided, 2" w/duct Collar, Door, Hi-Merv Seal 4= 4-Sided, 4" w/duct Collar, Door, Hi-Merv Seal Continued on next page. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 5

6 Nomenclature Code 21: Filter Type A= 2" Disposable E= Merv 8 (2" thick) Factory Installed G= Merv 13 (4" thick) Factory Installed Code 22: Water Coil- Indoor Air E= Waterside Economizer Code 23: Electric Heating- Indoor Air P= Controls for Electric Heat single 24V signal (Field installed Duct Heater by Others Code 24: Control Secondary Heat Type B= Boilerless Electric Heat E= Emergency Heat P= Primary Electric Heat (No Heat Pump Heating) S= Supplemental Heat Code 25: Desuperheater (Hot Water Generator) Code 26: Loop Pump Y Code 27: Coaxial Coil Supply Liquid Flow Control B= 2-Way, Motorized- 24V Valve Control, NO C= 2-Way, Motorized- 24V Valve Control, NC Code 28: Coaxial Coil Supply Liquid Auto Flow Reg D= 3.0 GPM E= 4.0 GPM G= 5.0 GPM Code 29: Coaxial Coil Supply Liquid Strianer Code 30: Always Y Code 31: Desuperheater Water Flow Options Codes 32-34: Always YYY Code 35: Water Coil Piping Package Option A= 3-Way, Motorized- 24V Valve Control, NO to Coax Codes 36-38: Always YYY Code 39: Primary Drain Pan Material S= Stainless Steel Code 40: Secondary Drain Pan Material Code 41: Compressor Insulation Code 42: Compressor Isolation B= Isolated Base Code 43: Insulation- Compressor Compartment S= Standard Insulation Package I= Indoor Air Quality (IAQ) Insulation Package R= Sound Reduction Package Code 44: Always Y Code 45: Insulation- Piping A= Insulated Piping Code 46: Always Y Code 47: Cabinet Finish A= Powder Coat G= Galvanized Steel Code 48: Cabinet Color T= Textured Charcoal Bronze W= Off White Code 49: Always Y Code 50: Fan Motor Control C= Various Speeds with 4 Adjustment Settings Code 51: Fan Motor Control location Code 52: Always YY Code 53: Disconnect Switch N= Non-Fused Code 54: Always Y Code 55: Control Transformer 1= 50VA 2= 75VA Code 56: Thermostat/Sensor Control S= Sensor Control T= Thermostat Control Code 57: Currrent Sensing Switches Code 58: Condensate Overflow Protection S= Sensor Code 59: High Pressure Switch A= 600 psi NC Code 60: Low Pressure Switch L= 7 psi NC Code 61: Low Temp. Protection Compressor Suction K= Thermistor 10K Code 62: Discharge Air Thermistor K= Thermistor 10K Code 63: Leaving Supply Fluid Temp K= Thermistor 10K Code 64: Entering Supply Fluid Temp K= Thermistor 10K Continued on next page. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 6

7 Nomenclature Code 65: Return Air Thermistor K= Thermistor 10K Code 66-67: Always YY Code 68: Terminal Block Connection Code 69: Emergency Switch for Electric Heat Code 70: Annunciator A= Annunciator Code 71: Reset Button Code 72: Monitoring Code 73: Emergency Stop Code 74: External Binary Output 1 Code 75: Expansion Device A= Thermal Exp. Valve Thermal Bulb & Equalizer Tube Code 76: Alarm Relay A= Alarm Relay (Dry Contacts) Code 77: Dirty Filter Sensor Code 78: Reversing Valve C= Normally Open in Cooling Mode Code 79: Outside Air Control Code 80: Always Y Code 81: Boilerless Electric Heat Setpoint GL= Glycol 28F WA= Water 55F Y Code 82: Freeze Fault Protection FF= Freeze Fault Protection Y Code 83: Occupied Setpoint Differential (1-5F) ST= Setpoint (1 F) Code 84: Unoccupied Setpoint Differential (2-10F) ST= Setpoint (2 F) Code 85: Hydronic Heating on Setpoint (70-90F) Y Code 86: BACnet Address YY Code 87: Always Y Code 88: Agency C= ETL, CETL, ARI Code 89: Conformance Code 90: Always Y Code 91: Extended Warranty Code 92: Product Style (always 1) WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 7

8 Electrical Legend Sch. Sym. AN1,2 CO1-04 Description LED Annunciator Fan Motor Capacitor C11-12 Capacitor, Compressor CP1,2 Compressor 1, 2 COE COS DAT DCS Condensate Overflow Sensor - WSE Condensate Overflow Sensor Discharge Air Temp Sensor Disconnect Switch EB1 Expansion Control Board 1 EB2 EWT FM HG HP LAT LP Exp. Control Board 2- Fan Spd CTRL Entering Water Temp Sensor Fan Motor Hot Gas Reheat Valve Actuator High Pressure Switch Leaving Air Temperature Sensor Low Pressure Switch LT1,2 Suction Line Temp Sensor 1,2 Sch. Sym. LWT M01 M11 MCB NCB OLP PL R15 R20 R25 RAT RV TR1 TR2 TR3 WSE Description Leaving Water Temp Sensor Contactor, Fan Motor Contactor, Compressor Main Control Board Network Control Board Overload Protector - Compr. Motor Loop Pump Relay, Alarm Output Relay, Loop Pump Relay, Hot Gas Reheat Return Air Temp Sensor Reversing Valve Transformer - Control Transformer - Fan Motor Transformer- Loop Pump Waterside Economizer Actuator WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 8

9 Unit Sections Front View Side View Blower Fan Assy Refrigeration Circuit Control Box Return Air Configurations Left-hand return with end discharge Left-hand return with straight discharge Right-hand return with end discharge Right-hand return with straight discharge WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 9

10 Blower Fan Assembly ECM Motor Detail 350 NP WARNING LABEL ECM Motor Nameplate Ref. No. Part Description Part Number Unit Size Blower Housing & Wheel Assy Band, Motor Mount Arm, Motor Mount ECM & Program 1 See ECM motor nameplate. 1 The PN for the ECM motor is found on the label (see illustration above). You may also contact Daikin Applied Parts Identification with the Unit Model & Serial Number to get the ECM Motor part number. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 10

11 Refrigeration Circuit Diagrams Evaporator/TXV Detail Condenser Detail Compressor Reversing Valve Piping TXV Bulb Water Temp Sensor 62 See Coremax Valve Assy Detail Compressor Mount Detail 151A 151B 151C 105 Coremax Valve Assy Detail WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 11

12 Refrigeration Circuit Components Ref. No. Description Part Number N/S Grommet, Compressor Mount N/S Hex Flange Nut, Compressor Mount N/S Sleeve, Compressor Mount WB Acorn Nut, Compressor Mount Spacer, Compressor Mount Grommet, Compressor Mount Isolation Plate, Compressor Mount Gasket, Compressor Mount Washer, Compressor Mount Nut, Compressor Mount Terminal Cover, Compressor Mount Compressor, 208/230V Compressor, 208/230V Compressor, 265V Overload Protector, Compr 208/230V Overload Protector, Compr 208/230V Overload Protector, Compr 265V COAX Coil Condenser, Copper Inner Tube COAX Coil Condenser, CUNI Inner Tube Adapter Evaporator Coil Assy N/S Reversing Valve until 4/ Reversing Valve 4/18 & later Reversing Valve until 6/ Reversing Valve 6/18 & later Solenoid, Reversing Valve until 4/ Solenoid, Reversing Valve 4/18 & later High Pressure Switch until 3/ High Pressure Switch 3/16 & later Low Pressure Switch until 9/ Low Pressure Switch 9/16 & later A Seat, Fitting B Core, Valve C Cap, Valve N/S= Not Shown. 1 Please contact Daikin Applied Parts Identification for Coil Assy, E-Coat. Continued on next page. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 12

13 Refrigeration Circuit Components, Continued Ref. No N/S Description Part Number Fusible Plug Assy Plug Only, 283 F Expansion Valve, 1T Expansion Valve, 1.5T Drain Pan Assy, SSTL- LH Drain Pan Assy, SSTL- RH N/S Gasket, Vinyl, 14.5" N/S= Not Shown. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 13

14 Hot Gas Reheat (HGRH) Ref. No. 200 Description Part Number Qty. HGRH Coil Assy, LH HGRH Coil Assy, RH Valve, Check Way Reclaim Valve until 12/ Way Reclaim Valve 12/13 & later Actuator, Reclaim Valve Please contact Daikin Applied Parts for E-Coat on coil assy. Water Flow Regulator 425 Ref. No. 425 Description Part Number Qty. Auto Flow Control Valve, 3/4" 3 GPM Auto Flow Control Valve, 3/4" 4 GPM Auto Flow Control Valve, 3/4" 5 GPM WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 14

15 Control Box MicroTech III Controls Diagrams 340 DCS M EB1 330 EB2 229 MCB AN1,AN2 320 WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 15

16 Ref. No. Description Control Box MicroTech III Controls Components Part Number Unit Size Bracket, Capacitor N/S Capacitor Boot Capacitor, 35MFD 440VAC Main Controller, MicroTech III * I/O Expansion Board Assy * LED Annunciator Assy Fan Speed Selection Board until 4/ Fan Speed Selection Board 4/14 & later Stand Off- PC Board Contactor, Compr, 2P, 30A until 12/ Contactor, Compr, 2P, 30A 12/17 & later N/S Relay, 1PDT Relay, 2PST Disconnect Switch, 10A See footnote 1. Disconnect Switch, 16A Transformer, 208/230V 50VA Transformer, 265V 50VA Transformer, 208/230V 75VA Transformer, 265/460V 75VA N/S Suction Line Temp Sensor (SLT) N/S Air Temp Sensor (DAT, RAT) N/S Water Temp Sensor (EWT, LWT) N/S= Not shown. 1 The disconnect switch depends on the unit features. Use the As-Built BOM on Parts E-Commerse, or get the specs from the installed disconnect, or contact Daikin Applied Parts Identification. * When ordering this board, please provide the software part number printed on the board s label. See control board photo on next page for label location. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 16

17 Control Box MicroTech III Controls MTIII Control Board Label Locations Label Label Label Label NOTE: When ordering the control board, please provide the software part number printed on the board s label. See above for label locations. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 17

18 Field Installed Accessories Filters and Filter Rack Description Qty. 015, 019 Filter Rack, 2" 1 Kit " Filter, Throwaway 12-Pack " Filter, Pleated, MERV 8 12-Pack " Filter, MERV 13 6-Pack MTIII Communication Module Kits Description Part Number BacNet Field Conversion Kit * LonWorks Field Conversion Kit * * Kit includes comm module card, sensors, mounting tabs, and IM. MTIII H-8 Harness Assembly Kit Description Part Number MTIII, H-8 Output Wire Harness Assembly Kit Motorized Valves Description Kit * Actuator Body 2-Way Valve Kit, Motorized, NC, 3/4" NPT Way Valve Kit, Motorized, NC, 3/4" Sweat Way Valve Kit, Motorized, NO, 3/4" NPT Way Valve Kit, Motorized, NO, 3/4" Sweat * Refer to IM 1151 for installing a motorized valve kit on MicroTech III units. Manual Valves Description Qty Part Number 2 pack Combination Shutoff/Balancing Valve with Memory Stop Ball Valve- 3/4" 10 pack WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 18

19 Description 1 For use with , , , or For use with , , , and Field Installed Accessories Continued Sensors Part Number 5.25 X 7" Adapter Plate for Sensors , , , X 5.5" Adapter Plate for Sensors , , , X 5.3" Adapter Plate for Sensors , , , Remote Sensor for Thermostat , Remote Sensor for Thermostat , Basic Room Sensor w/nsb, Override and Status LED Room Sensor, Digital Adj, 4-Button w/ Override, Occupancy Switch & Temp Display Room Sensor w/cool/warm Temp Adj. & Occupancy Switch Room Sensor, Digitally Adj, Temp & Humidity Display Wall Sensor, Adj. Cool/Warm, Occupancy Switch Trim Ring for Sensors , , or Indoor Sensor for Outdoor Sensor for Wall Plate for Remote TStat, Insulated Wall Plate for Remote TStat Thermostats Description Part Number Programmable Touch-Screen TStat Wall Stat: AC/DC, ACO, 7-day Programmable, 2 Heat/2 Cool with Wall Plate Wall Stat: AC/DC, ACO, Non- Programmable, 2 Heat/2 Cool, NSB & OR with Wall Plate TStat Non-Programmable- 2 Heat/2 Cool, ACO & MCO TStat Programmable- 2 Heat/2 Cool, ACO & MCO and 7-day TStat Programmable/Non-Programmable- 2 Heat/2 Cool, ACO, Touchscreen, WIFI TStat Programmable/Non-Programmable- 2 Heat/3 Cool, ACO, Touchscreen TStat Programmable/Non-Programmable- 2 Heat/2 Cool, ACO, Touchscreen, WIFI TStat Programmable/Non-Programmable- 2 Heat/3 Cool, ACO, Touchscreen TStat Guards Description Qty Part Number TStat Guard Each TStat Guard 10- Pack WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 19

20 Description Field Installed Accessories Continued Loop Pump Modules Part Number Hose Kit, 1.0" x 12 ft. Hose, 1/2" Fittings Hose Kit, 1.0" x 12 ft. Hose, 3/4" Fittings Hose Kit, 1.0" x 12 ft. Hose, 1.0" Fittings Hose Kit, 1.0" x 12 ft. Hose, No Fittings Single Pump, Geothermal Loop- Cast Iron Single Pump, Geothermal Loop- Bronze Dual Pump, Geothermal Loop- Cast Iron Dual Pump, Geothermal Loop- Bronze Relay Pump Kit Waterside Economizer Description RH LH 3-Way Valve, Motorized, 3/4" Sweat Actuator Motor, NC, 24V WSE Coil Assy until 03/ WSE Coil Assy 03/15 & later Unit Hanger Description Part Number Unit Hanger Kit Kit includes four (4) brackets (p/n ), four (4) grommets (p/n ), and hardware. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 20

21 Field Installed Accessories Continued Hoses Description Specification 2 Foot 3 Foot Hose Kit, Fire Rated Condensate 3/ Hose Kit, Plastic Condensate 3/ Hose Kit, Fire Rated Supply/Return (2 Pack) 3/ Auto Flow Supply and Return w/ball Valves Flow Control Hose Kit, Fire Rated Supply/Return- 3/4" Includes: Supply Line: Ball valve with one port and a 24" stainless steel hose with swivel. Return Line: Combination flow controller & ball valve with two ports and a 24" stainless steel hose with swivel. Auto Flow Supply and Return w/ball Valves and Strainer Flow Control Hose Kit, Fire Rated Supply/Return- 3/4" Includes: Supply Line: Combination ball valve & y-strainer, blow down valve, with one port and a 24" stainless steel hose with swivel. Return Line: Combination flow controller & ball valve with two ports and a 24" stainless steel hose with swivel. 3.0 GPM N/A 3.5 GPM N/A 4.0 GPM N/A 4.5 GPM N/A 5.0 GPM N/A 6.0 GPM N/A 3.0 GPM GPM GPM GPM GPM GPM Hose Kit Supply and Return w/ball Valves 3/ Hose Kit Supply and Return w/ball Valves and Strainer 3/ Hose Kit Jumper Hose Kit w/90 Adapter 3/4" x 4 Ft N/A = Not Applicable. Note: Refer to IM 1226 for Daikin Fire Rated Hoses & Hose Kits and for installation instructions. WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 21

22 Part Number Kit Field Installed Accessories Continued MicroTech III Temperature Sensors Tennant Override Setpoint Adjustment Status LED Note: Can only be used in conjunction with a communication (Comm.) card. See OM 931 for required jumper settings. Fan & Mode Switch Yes No No No Yes 55 to 95 F (12 to 35 C) Yes Yes Yes -3 to +3 F (-1.5 to 1.5 C) No Yes Description * IM is included in Kit. ** Kit components listed below. Microtech III Unit Control Accessories ** Multiple Unit Control Panel: Allows a master unit controlled by a single thermostat, to operate up to 3 secondary units. Not Recommended for use with a Boilerless System Kit. Part Number Boilerless System Kit with I/O Expansion Board * Boilerless System Kit without I/O Expansion Board Multiple Unit Control Panel Kit Ref. Part Description Qty. No. Number 310 Cover, Control Box Circuit Board Stand Off, Circuit Board Box WSHP; WGSH1 015, 019 Design 1 Rev. N 10/18 RPL / Page 22

23 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin SmartSource Single Stage WSHP Daikin McQuay SmartSource Single Stage WSHP WGSH 015, 019 Design 1 Critical Components Unit Sizes Voltage Part Number Control Control Board, MicroTech III ALL ALL Compressor Compressor /60/ Compressor /60/ Compressor /60/ Compressor /60/ Blower Motor ECM & Program ALL ALL See motor nameplate Blower Fan Assembly Blower Housing & Wheel Assy ALL N/A Sensor Line Temp Sensor (SLTS) ALL N/A Air Temp Sensor (DAT, RAT) ALL N/A Water Temp Sensor (EWT, LWT) ALL N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. N 10/2018 CPL Page 1 of 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018 Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4 Replacement Parts List No. 700050500 Revision G 07/2018 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 3 009, 012 Design 4 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1) Replacement Parts List No. 057103200 Revision K 03/2018 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 007-012 Vintage B WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS 007-012 Design A (1) WFAE,WFAS,WFDD,WFDE,

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998 Replacement Parts List No. 057101600 Revision E 06/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B Last Manufactured: 1998 To find your Daikin Applied parts distributor,

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) Replacement Parts List 057103500 Revision P 03/2016 McQuay Vertical Water Source Heat Pump FCV, FCG & FCW 036 & 042 Vintage B WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) WFDA, WFDD,

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101700 Revision B 02/2017 McQuay Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 015-019 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700015400 Revision R 03/2019 McQuay Thinline Vertical Fan Coil FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1 To find your Daikin Applied parts distributor,

More information

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101500 Revision B 02/2017 AAF Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 006-012 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016 Replacement Parts List 110502400 Revision Q 07/2016 McQuay Console Water Source Heat Pump WWAF,WWAG,WWAH,WWAS,WWAX,WWCQ WWDA,WWDB,WWDD,WWDE,WWDF,WWDG,WWDH, WWDJ,WWDN,WWDS,WWFQ,WWLA,WWLB,WWLC,WWLL, WWMA,WWMB,WWMC,WWMD,WWMF,WWMG,WWMH,

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL Applied Decentralized Products Water Source Heat Pump / Rev.A HWH, HWH HWW, HWW PL-1101-4 Nomenclature Nomenclature Field Installed Thermostats & Subbases For Mark IV/AC Control Units Code 03 must be M.

More information

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6)

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6) Replacement Parts List No. 70009600 Revision D 0/207 McQuay Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054 UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6) To find your Daikin Applied parts distributor,

More information

Catalog Vertical Stack Water Source Heat Pumps

Catalog Vertical Stack Water Source Heat Pumps Catalog 1105-15 Vertical Stack Water Source Heat Pumps Model WVHF - Cabinet Model WVHC - Chassis (Standard Range) Model WVHW - Chassis (Geothermal Range) Unit Sizes 009 036 R-410A Refrigerant Model VHF

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012 Replacement Parts List No. 700006200 Rev. J 2/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07- Design C (3) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table of Contents

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet

More information

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001 Replacement Parts List No. 1105050 New 05/2001 McQuay Thermal Systems Absorption Chiller ME, MF 21-33 Vintage A Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012 Replacement Parts List No. 110511900 Rev. P 1/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07-15 Vintages B and B+ (2) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important REPLACEMENT PARTS MANUAL WATER SOURCE HEAT PUMPS MODELS: GTB-A GTA300UDAA GTA0UDAA GTC3S2-ADC GTCS2-ADC GTC0S2-ADC GTC3S2-ADN GTCS2-ADN GTC0S2-ADN Blower Section Coil Section Coil Section General Notes

More information

Si Series Model CE Residential Geothermal Heat Pump

Si Series Model CE Residential Geothermal Heat Pump Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990 Replacement Parts List No. Revision B /17 McQuay Climate Control Singer Water Source Heat Pump LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW 119 intage B Last Manufactured: 199 To find your Daikin Applied

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL PACKAGE HEAT PUMP Models: PH242-A PH363-A PH302-A PH363-B General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B Replacement Parts List No. 0700053000 Revision C 02/2018 Daikin Magnitude TM Magnetic Bearing Centrifugal Chiller WME 0501S, 0502S, 0701S, 0702S Vintage B To find your Daikin Applied parts distributor,

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control GC Infinityr Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.8-4.7, 18.5-32.0 EER (Closed Loop) S 4.5-5.2, 23.1-37.0 EER (Open Loop) S Optional

More information

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010 Replacement Parts List No. 700018100 Revision New 07/2010 McQuay Steam/Hot Water Unit Heater UDH 040-960 Vintage C Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

R-410A 50Hz & 60Hz. Renewal parts /3/ MODELS ONLY. Issue Date: September 07, 2011

R-410A 50Hz & 60Hz. Renewal parts /3/ MODELS ONLY. Issue Date: September 07, 2011 WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL Renewal parts Supercedes: 20.26-RP (20) Form: 20.26-RP (9) MODELS YCWL0056, 0064, 0074, 0084, 0094, 0096, 004, 08, 026, 032, 056, 077, 098, 0200, 0230, 0240,

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: WLB-A WLB-A WLB-B WLB-F General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL/POOL MODELS: MVB 504A THRU 2004A CATALOG NO. 9300.745 Effective: 11-01-18 Replaces: 12-01-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 504A, 754A, 1104A, 1504A & 2004A MODEL TYPES: MODULATING

More information

McQuay. Classroom Unit Ventilator Ceiling Mounted. UAHB, UAHF, UAHR, UAHV 07, 10, 13, 15, 20 Design F (6)

McQuay. Classroom Unit Ventilator Ceiling Mounted. UAHB, UAHF, UAHR, UAHV 07, 10, 13, 15, 20 Design F (6) Replacement Parts List No. 70002300 Revision J 03/207 McQuay Classroom Unit Ventilator Ceiling Mounted UAHB, UAHF, UAHR, UAHV 07, 0, 3, 5, 20 Design F (6) To find your Daikin Applied parts distributor,

More information

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017 Replacement Parts List No. 700005800 Revision J 12/2017 McQuay Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

McQuay Rooftop Water Source Heat Pumps Catalog 1106

McQuay Rooftop Water Source Heat Pumps Catalog 1106 McQuay Rooftop Water Source Heat Pumps Catalog 06 Model RWA, RGA Downflow Discharge and Return Model, RWC, RGC Horizontal Discharge and Return Unit Sizes 036 R-A Refrigerant Model RWA Engineered for flexibility

More information

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017 Replacement Parts List No. 700014000 Revision B 07/2017 McQuay Two-Stage Centrifugal Chiller WTC 700 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control GP Performance Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.5-4.0 COP, 15.5-24.5 EER (Closed Loop) S 4.0-4.6 COP, 19.6-30.0 EER (Open Loop)

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL MODELS: MVB 503A THRU 2003A CATALOG NO. 9300.744 Effective: 12-01-17 Replaces: 03-01-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 503A, 753A, 1003A, 1253A, 1503A, 1753A & 2003A MODEL TYPES:

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

Daikin McQuay. Vertical Unit Ventilator. UAVS, UAVV, UAVR, UAVB Design F (6) Replacement Parts List No Revision P 10/2018

Daikin McQuay. Vertical Unit Ventilator. UAVS, UAVV, UAVR, UAVB Design F (6) Replacement Parts List No Revision P 10/2018 Replacement Parts List No. 70000500 Revision P 0/208 Daikin McQuay Vertical Unit Ventilator UAVS, UAVV, UAVR, UAVB 07-5 Design F (6) To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important REPLACEMENT PARTS MANUAL WATER SOURCE HEAT PUMPS MODELS: GTB-A GTA300UD-A GTA300UDAA GTA0UD-A GTA0UDAA GTC3S-ADC GTCS-ADC GTC0S-ADC GTC3S-ADN GTCS-ADN GTC0S-ADN Blower Section Coil Section Coil Section

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE A WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: 150.7-RP1 (709) Form: 150.7-RP1 (810) MODELS YCRL0064, 0074, 0084, 0096, 0118, 016, 0156, 0177, 0198, 000, 030, 060, 0300, 0345, 0385,

More information