1 Replacement Parts List No Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 5 Nomenclature Unit Model and Serial Number... 6 Unit Code Index Control & Sensor Location Diagrams... 3 Electrical Legend Section A- Outdoor/Return Air Section Notes % Outside Air Damper with Hood- No Return Air Plenum % Outside Air Damper Detail w/act % Outside Air Section w/ ACT % Economizer Section with Barometric Exhaust Damper- Units w/o Return Air Fans % Economizer Section with Barometric Exhaust Damper- Units w/ 40 Return Air Fans % Economizer Section with Prop Exhaust Fan & Damper % Economizer Damper w/ ACT3- Diagrams % Economizer Damper w/ ACT3- Components California Title 24 Assembly: Code 33= *F*** Return Air Plenum Isolation Damper w/ Actuator ACT Prop Exhaust Fan & Damper... 29, 30 Design Flow Detail Return Air Fan: Code 2= 40B* Return Air Fan Fan Mounts: Code 2= 40B* Return Air Fan Motors... 34, 35 Section Mounted Controls- OAE, RAE, LT, S, REC Section A2- Outdoor/Return Air w/ Heat Recovery Section Notes Cabinet Gaskets, Doors, Hardware, Exhaust Hoods Base Components, Hood, Dampers Return Air Fan: Code 2= 40B*... 40, 4 Low Leak Damper Detail Bypass L Type Damper Detail Heat Recovery/Enthalpy Wheel, Motor, Drive Components, Seals AFD60 Frost Protection Inverter: Code 24= F Section Mounted Controls- OAE, RAE, RAT, EAT, LAT Section Mounted Controls- SD2, HUM, LT, S, REC Section B- DrawThru Filter/Blank Section Notes Section Mounted Controls- PC5, LT3, S3, REC Filters Air Blender Section Components Magnehelic/Differential Pressure Gauges Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes... 5 Section Mounted Controls- LT2, S2, REC Section D- DrawThru Cooling Section Notes Section, Small Face Coils Section, Large Face Coils Section E- Spacer Section & Section E- DrawThru Heat Section Notes Section Mounted Controls- LT8, REC8, S8- Section Mounted Light Hot Water OR Steam Coil Heat, Mixing Valves & Actuator VM Section F- Supply Air Section Notes Air Foil Fan- Double Width- RPS Units Air Foil Fan- Single Width- RDT Units Fan Mounts- 27 Airfoil Double Width Fan Fan Mounts- 30 Airfoil Double Width Fan Fan Mounts- 33 Airfoil Double Width Fan... 6 Fan Mounts- 40 AFSW- RDT Units Fan Mounts- 44 AFSW- RDT Units Supply Air Fan Motors... 64, 65 Belt Guards Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 2

3 Contents Continued Section F- Supply Air Section, Continued Inverters & Inverter Bypass Control Box Motor HP Motor HP , 69 Motor HP , 7 Inverters Line Reactors Section Mounted Controls- PC7, HL22, LT0, S0, REC0, UV Lights Section Mounted Controls- MAT, EFT, SAT, DAT, OAT, SD Section Mounted Controls- SCB- Split Junction Box- TB25, TB27, TB28, PB0, PB9, PB20, PB Section G- BlowThru Heat Section Notes... 8 Option : Blank/Empty Section Diffuser... 8 Option 2: Hot Water OR Steam Coil Heat Mixing Valves and Actuator VM Option 3: Electric Heat Heaters, Diffusers, Hi Limit Cutouts HL- 20, , 84 Electric Heat Control Box Option 4- Gas Heat Heat Exchangers & Vestibules- 200, 250 MBH Furnaces Heat Exchangers & Vestibules- 320, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces... 9 Modulating Burner Hi Turn Down Burner Modulating Burner Controls- MicroTech III Controls Hi Turn Down Burner Controls- MicroTech III Controls Gas Train- Inlet Gas Train- Controls: GV,GV2, GV3, GV4, GV5, GV6, VM Gas Train- Outlet Gas Train- Damper Linkage Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting... 09, 0 Section H- BlowThru Heat Blank Access Section Notes... Access Door Latching Assemblies, Key, & Lock (All Sections)... Section I- BlowThru Cooling Section Notes... 2 Section Mounted Controls- LT6, S6, REC Section J- Final Filter Section Notes... 3 Section Mounted Controls- HL23, PC Filters... 4, 5 Section K- Discharge Plenum Section- (RPS) Notes... 6 Section Mounted Controls- OAT, DAT, SD... 6 Discharge Damper Assembly w/ Actuator ACT Section L- Out-of-Airstream Blank Access Section Notes... 8 Section Mounted Controls- LT20, REC20, S Section M- Condenser Section Notes... 9 Condenser Fan Deck Assembly: Code 47= , 2 Quiet Fan Assembly: Code 47= Compressors & Compressor Components: Code 44= V, W Compressors Circuit # Compressors Circuit # Inverter Compressor Components Compressor Mounting Components Condenser Coil Guards Pressure Controls Box... 28, 29 Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C Inverter Compressor Control Box... 3 Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 3

4 Contents Continued Section N- Main Control Box Notes Control Box Component Label Diagram Control Panel MicroTech III Units with Controller: Code 2= *E, *F, *W- Diagram MicroTech III Units with Controller: Code 2= *E, *F, *W- Components... 35, 36 Power Panel Power Panel Diagram Terminal Blocks, T Transformer & Fusing Fusing, Phase Protection, Ground Fault, Power Blocks Power Blocks, continued, Receptacle, Plugs Disconnect Switch DS, Supply MMP0 & M0 Fan Contactor, Return MMP20 & M20 Fan Contactor Diagrams Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components Compressor Motor Protector MMP, 3, 5 & Contactor M, 3, 5 Unit Size 045D Unit Size 050, 05D... 5 Unit Size 063D Unit Size 074D Inverter Compressor Fuseblock & Fuse Components FB2M SpeedTrol Condenser Fan Fusing: Code 47= 2, Energy Recovery Wheel Contactors, MMPs, & Fusing Intelligent Equipment Section O- Refrigeration Tubing Notes Refrigeration Tubing Diagram Valves, Filter Driers, Sight Glasses... 59, 60 Hot Gas Reheat... 6 Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 4

5 Parts List Revision History Rev. Date Description New 03/6 New. Used form # Rev. AK as a starting point. A 04/6 Page 24: Added Sightglass and gasket p/ns & dwg. B 04/6 Page 82: Added Freezestat FS p/n C 06/6 Page 4: Changed Intelligent Design to Intelligent Equipment. Page 99: Updated Ref. #34 TB p/ns & qtys. Page 9: Rewrote Notes. Page 2: Deleted Coil Guard p/ns. Moved info. to NEW pg. 27. Added footnotes. Page 22: Added footnote # 2. Page 24: Added Compressors. Deleted footnote # 2. Page 27 (NEW): Added pg. for updated Condenser Coil/Vandal guards. Repaginated the form & updated the TOC. Page 34 (OLD) 35 (NEW): Added MTIII Remote Keypad & Remote Interface p/ns. Page 56 (OLD) 57 (NEW): Rewrote notes for IE. Added coding to pg. header. Updated dwg. D 06/6 Page 7: Added TB35-37 info. Page 28, 29: Added new TB37 p/n for units. Rewrote footnotes & updated TB36, 37 descriptions. E 05/7 Page 7: Rewrote footnote #. Page 34, 54: Corrected coding. Page 37: Rewrote Notes. Page 47: Updated HUM p/ns. Page 75: Rewrote footnote #. Page 99, 00: Added footnote # & footnote notation. Page : Updated Latching Assy. descriptions. Rewrote footnote # 2. Page 9: Rewrote Notes. Page 36: Updated/corrected R63 p/ns. Page 55: Updated Ref # 9A Fuse p/ns. Rewrote footnotes and footnote notation. Page 56: Rewrote footnote # 3. Page 60: Updated HGBP p/ns and rewrote footnotes. F 08/7 Page 60: Added Check Vlv. p/ns. Page 6: Updated/corrected table per EPS_5229 Rev T, and deleted footnote # 2. G 09/7 Page 6: Deleted PVM4. (RCS units only.) Page 39: Added /7 & Later PVM components. Corrected qtys. H 0/7 Page 25: Added Sight Glass/Prism p/n, Bub., & footnote #. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 5

6 Nomenclature Unit Model and Serial Number Unit Model Number R P S 050 D A Nominal Capacity (Tons) Ex. 050= 50 Tons Zone S, T= Singlezone Unit Unit Configuration P= Heating, mechanical cooling D= Heating, mechanical cooling, DrawThru Roofpak: R= Roofpak Applied Rooftop Design Vintage Heating Medium A= Natural Gas E= Electric S= Steam W= Hot Water Y= None (cooling only) Serial Number Plant Identification Abbreviation FBO = Faribault, MN U= Unit Year of Manufacture 4= 204, 5= 205, 6= 206, 7= 207, etc. FBO U Month of Manufacture 0= Jan. 04= Apr. 02= Feb. 05= May 03= Mar. 06= Jun. Serial Number (build sequence) 07= July 08= Aug. 09= Sept. 0= Oct. = Nov. 2= Dec. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 6

7 Nomenclature Unit Code Index RPS 050D S W Y EY D 27 AL P LE A 3 CD S20 BY DE 40B2 JEY Code YYAYA Y AH Y CYYS 4Z083D YYYYYY YYYYYY 30A2 LEY YYYYY WE3E CYYS 4Z083D YYYYYY Y Y BY Y M TY V 2 Y D Y EEEEEE YY YY YY YY YY YY 0987A 252A XX A A Y 047C Y Y YY YYYYYYYY General Options Unit Model Codes that Pertain: 03, 05, 06, 07, 33, 6-72 Auxiliary Controls/Remote Sensors Unit Model Codes that Pertain: 2, 3, 6, 7, 8 Sections A, A2 Return/Outside Air/Heat Recovery Options Unit Model Codes that Pertain: 9, 20, 2, 22, 24, 58 Sections B, C, D, E DrawThru Cooling Sections Section B- Filter Section Unit Model Codes that Pertain: 25, 33, 50 Section C- DrawThru Blank Access Unit Model Codes that Pertain: 26, 4, 5 Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 03, 27, 28 Section E- Spacer Section (RPS) Unit Model Codes that Pertain: 04, 30 Section E- DrawThru Heating Section (RDT) Unit Model Codes that Pertain: 04, 30 Section F- Supply Fan Options Unit Model Codes that Pertain: 3, 32, 59, 08, 4, 5, 40, 49 Sections G, H, I BlowThru Options Section G= BlowThru Heat/Blank Access Unit Model Codes that Pertain: 04, 34 Section H= BlowThru Blank Access Unit Model Codes that Pertain: 34, 38 Section I- BlowThru Cooling Sections Unit Model Codes that Pertain: 03, 35, 36 Section J- Final Filter Section Unit Model Codes that Pertain: 39 Section K- Discharge Plenum Section Unit Model Codes that Pertain: 40 Section L- Out-of-Airstream Blank Access Section Unit Model Codes that Pertain: 4 Section M- Condenser Section Unit Model Codes that Pertain: 09, 23, 43, 44, 45, 47 Section N- Main Control Panel Unit Model Codes that Pertain: 08, 09,, 2, 3, 4, 5, 6, 7, 8, 23 Section O- Refrigeration Tubing Unit Model Codes that Pertain: 45, 46, 54 An "X" located in Code 60 in a code string indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas with the EXCEPTION of special text that ONLY indicates the presence of variable speed scroll compressors. So, in cases where sections of the unit have special features (not strictly related to the presence of inverter compressors), it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 7

8 Nomenclature Unit Code Index, Continued Code 03= Cooling Coil S= Small L= Large Code 04= Heat Type A= Natural Gas E= Electric S= Steam W= Hot Water Y= None Code 05= Unit Split F= Fan/Heat Y= None Code 06= Insulation and Liners =, 3/4# with liners on doors 2= ½, ½# with solid liners on doors & ceilings 3= ½, ½# with perforated liners in plenums, solid elsewhere 4= ½, ½# with solid liners on doors, ceilings and floors 5= ½, ½# with perforated liners in plenums, solid elsewhere (including floors) 6= ½, ½# with SS Solid Liners on doors, ceilings and floors Code 07= Approval Agency Listing CC, CD, CY= ETL Canada EM, EU, EY, YU= ETL/MEA- USA YY= None Code 08= Main Control Box Location D= Discharge Plenum (RPS) F= Supply Fan Section (RDT) Code 09= Unit Voltage 2= 208/60/3 29= 230/60/3 27= 460/60/3 37= 575/60/3 Code 0= Starting Option AL= Across- The- Line Code = Field Power Connection and Disconnect P= Single Power Block: Complete Unit Q= Two Power Blocks: EH/Balance of Unit R= Two Power Blocks: Fans & Controls/Balance of Unit A2= One, thru-the-door Disconnect: Complete Unit C2= Two, thru-the-door Disconnects: SAF&RAF&CB/Balance of Unit B2= Two, thru-the-door Disconnects: EHB/Balance of Unit D2= Three thru-the-door Disc.: EH/SAF&RAF&CB/Balance of Unit Code 2= Temperature Controls MicroTech III Controls Digit : Communication Type L= LonWorks B= BACNet w/mstp E= BACNet w/ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit 2: Control Type E= Discharge Air w/ Static Pressure Control F= Space OR Zone Ctl. W= Discharge Air w/ Space Control Code 3= Air Flow Controls Y= None = Duct Sensor 2= 2 Duct Sensors 3= Duct and Space Sensor 4= Space Sensor Code 4= Inverters Y= None Separate Section = SA Fan only w/ Bypass 2= SA & RA Fans w/ Bypass 4= RA only w/ Bypass No Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan w/o Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan w/o Bypass Code 5= Inverter Brand Y= None A= ABB Inverter G= Graham Inverter Q= Schneider Inverter R= Reliance Inverter S, B= Daikin Applied Inverter F= Field Installed Inverter controlled by MicroTech Code 6= Smoke Detectors Y= None = Return Air Fan Section 2= Supply Air Fan Section 3= (RAF) + (SAF) Code 7= Misc. Aux. Controls C G Y= None F= Freezestat (Steam OR HW Heat only) P= Phase Failure G= Ground Fault Protection L= Line Reactors (Inverter w/ separate section only) A= Freezestat & Phase Failure (Steam OR HW Heat only) B= Freezestat & Ground Fault (Steam OR HW Heat only) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam OR HW Heat only) E= Freezestat & Line Reactors (ST/HW Heat & Inverter w/separate section only) H= Phase Failure & Line Reactors (Inverter w/ separate section only) J= Freezestat, P.F. & Line Reactors (ST/HW Heat & Inverter w/separate section only) K= Ground Fault, Phase Failure & Line Reactors (Inverter w/ separate section only) = UV Lights 2= UV Lights + F 3= UV Lights + P 4= UV Lights + L 5= UV Lights + A 6= UV Lights + E 7= UV Lights + H 8= UV Lights + J C= Differential Enthalpy Y= None (includes mechanical enthalpy) Code 8= Misc. Controls/ Unit Length A, S, Y = None ( = Air Handler Length [in.]) R = Remote Keypad ( = Air Handler Length [in.]) Code 9= Return Air Plenum YY= No section BY= Bottom Return BB= Bottom Return w/burglar Bars BE= Bottom Return w/isolation Damper HY= Back Return LY= Left Return SY= Side Return Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 8

9 Code 20= Outdoor Air Options YY= None AE= 00% Outside air Damper w/ Hood & Actuator AY= 00% Outside air damper w/ Hood w/o Actuator BE= 0-30% Outdoor air section w/ Actuator BY= 0-30% Outdoor air section w/o Actuator DE= 0-00% Econ. w/ barometric exhaust Damper w/ Act. DY= 0-00% Econ. w/ barometric exhaust Damper w/o Act. EE= 0-00% Econ. w/ power closure exhaust Damper w/ Act. EY= 0-00% Econ. w/ power closure exhaust Damper w/o Act. HE= 0-00% Econ. w/ prop exhaust Damper w/ Act. HY= 0-00% Econ. w/ prop exhaust Damper w/o Act. FE= same as DE + Design Flow FY= same as DY + Design Flow GE= same as EE + Design Flow GY= same as EY + Design Flow JE= same as HE + Design Flow JY= same as HY + Design Flow KE= same as DE + Ebtron Sensor KY= same as DY + Ebtron Sensor LE= same as EE + Ebtron Sensor LY= same as EY + Ebtron Sensor ME= same as HE + Ebtron Sensor MY= same as HY + Ebtron Sensor 3E= Energy Recovery Economizer, Low CFM- 6 wheel 4E= Energy Recovery Economizer, Low CFM- 2 wheel 5E= Energy Recovery Economizer, High CFM- 6 wheel 6E= Energy Recovery Economizer, High CFM- 2 wheel Code 2= Return Air Fan YYYY= No Return Air Fan 40B()= 40 Airfoil Single Width ()= Isolator type: = Rubber-in-Shear (RIS) 2= Spring 3= Spring w/ seismic restraints Code 22= Return Air Fan Motor YYY= No Return Fan J E Y Y= None S= Shaft Ground Kit E= High Eff. ODP motor H= High Eff. Totally-Enclosed J= Premium Eff. ODP K= Premium Eff. Totally-Enclosed G= 2.0 HP L= 0.0 HP Q= 30.0 HP H= 3.0 HP M= 5.0 HP J= 5.0 HP N= 20.0 HP K= 7.5 HP P= 25.0 HP (prop exhaust option is always J [5.0 HP]) Nomenclature Unit Code Index, Continued Code 23= Miscellaneous Electrical Options Digit : UV Lights Y= None Digit 2: Plenum/Vestibule Lights Y= None Digit 3: SpeedTrol, Energy Recovery, HGRH Inverter Y= None A= ABB B= Daikin Applied Q= Schneider Digit 4: 5V Service Outlet Y= Field Supplied 5V Power, Outlet by Factory F= Factory supplied Line Voltage & Outlet Digit 5: Intelligent Equipment/IE Y= None A= Intelligent Equipment (IE) Code 24= Exhaust Fans OR Frost Protection Y= None = Prop Exhaust Fan w/ Hood 2= 2 Prop Exhaust Fans w/ Hood F= Heat Recovery Frost Protection Inverter Code 25= DrawThru Filter Section Digit : Section Type A= 2 Angular (24 Section) F= Flat (24 Section) G= 4 Angular- 24 section L= Large Staggered- 48/24 section S= Staggered- 48 section D= Blank 24 section E= Blank 48 section Digit 2: Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/intersept H= Throwaway 85% Efficient D= Cartridge 65% Efficient (w/ 2 Prefilters) E= Cartridge 95% Efficient (w/ 2 Prefilters) G= Cartridge 95% Efficient w/intersept (w/ 2 Prefilters) Code 26= Blank DrawThru Section Y= No section E= Blank 24 Section F= Blank 48 Section Code 27= DrawThru Drain Pan/Cooling Coil Section Digits - 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only (48 section) GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY only) Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 9

10 Nomenclature Unit Code Index, Continued Code 28= DrawThru Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D D= Lanced Aluminum C= Hi-F Copper w/ SS casing 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch 2= 2 Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 29= DrawThru Heating Coil YYYYYY= No Heating Coil Code 30= DrawThru Heating Section (RDT only) OR Blank Spacer Section (RPS only) YYYYYY= No Heating Section EEEEEE= Blank 24 Section FFFFFF= Blank 48 Section Hydronic Heat (RDT only) W22 J 3 E E= Electric Actuator Y= Less Actuator 2= 2 Way Steam Valve Y= No Valve 3= 3 Way HW Valve E= ¼ Valve Pkg. H= 2½ Valve Pkg. F= ½ Valve Pkg. J= 3.0 Valve Pkg. G= 2.0 Valve Pkg. Y= No Valve Pkg. S= 5JA060H (6FPI, Row 5J Steam Coil) S2= 5JA20H (2FPI, Row 5J Steam Coil) S3= 5JA0602C (6FPI, 2 Row 5J Steam Coil) S4= 5JA202C (2FPI, 2 Row 5J Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W22= 5WS0902C (9FPI, 2 Row 5WS HW Coil) Electric Heat (RDT only) E020 Y Always Y = Stage 2= 2 Stages 4= 4 Stages 6= 6 Stages E020= 20 KW Heater E200= 200 KW Heater E040= 40 KW Heater E240= 240 KW Heater E060= 60 KW Heater E080= 80 KW Heater E00= 00 KW Heater E20= 20 KW Heater E60= 60 KW Heater Code 3= Supply Air Fan 27A()= 27 Airfoil Double Width (RPS only) 30A()= 30 Airfoil Double Width (RPS only) 33A()= 33 Airfoil Double Width (RPS only) 40B()= 40 Airfoil Single Width (RDT only) 44B()= 44 Airfoil Single Width (RDT only) ()= Fan Isolators = Rubber-in-Shear (RIS) 2= Spring 3= Spring w/seismic Snubbers Code 32= Supply Air Fan Motor K E Y Y= None S= Shaft Ground Kit E= High Eff. ODP motor H= High Eff. Totally-Enclosed J= Premium Eff. ODP Motor K= Premium Eff. Totally-Enclosed H= 3.0 HP M= 5.0 HP R= 40.0 HP J= 5.0 HP N= 20.0 HP S= 50.0 HP K= 7.5 HP P= 25.0 HP L= 0.0 HP Q= 30.0 HP Code 33= Miscellaneous Mechanical Options Digit : Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DT & BT sections Digit 2: California Title 24 Y= None F= Economizer w/ Fault Detection/Diagnosis (FDD) Digit 3: Ebtron Air Flow Y= None S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold) Digit 4: Heating Coil Options Y= None E= Electrofin Coating Digit 5: Cooling Coil Options Y= None E= Electrofin Coating Code 34= Blow Thru Heat Section (RPS only) YYYYYY= No section, cooling only BBBBBB= Blank 48 section, no heat, cooling only Gas Heat Breakdown: 020 S S C A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position E= Modulating Burner R= Modulating Burner/with H.P. Regulator Range= 2-3 psi S= Modulating Burner/with H.P. Regulator Range= 5-0 psi H= Hi Turn Down Burner 20: T= Hi Turn Down Burner 20:/with H.P. Regulator Range= 2-3 psi U= Hi Turn Down Burner 20:/with H.P. Regulator Range= 5-0 psi S= Stainless Steel Heat Exchanger MBH (in 0 s) ex. 020= 200 MBH [020,025,032,040,050,064,065,079,080,00] Hydronic Heat Breakdown: W22 J 3 E 2= 2 Way Steam Valve 3= 3 Way HW Valve E= Electric Actuator E= ¼ Valve Pkg. H= 2½ Valve Pkg. F= ½ Valve Pkg. J= 3.0 Valve Pkg. G= 2.0 Valve Pkg. Y= No Valve Pkg. S= 5JA060H (6FPI, Row 5J Steam Coil) S2= 5JA20H (2FPI, Row 5J Steam Coil) S3= 5JA0602C (6FPI, 2 Row 5J Steam Coil) S4= 5JA202C (2FPI, 2 Row 5J Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W22= 5WS0902C (9FPI, 2 Row 5WS HW Coil) Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 0

11 Nomenclature Unit Code Index, Continued Code 34= Blow Thru Heat Section, Continued Electric Heat Breakdown: E020 Y Always Y = Stage 2= 2 Stages 4= 4 Stages 6= 6 Stages E020= 20 KW Heater E20= 20 KW Heater E040= 40 KW Heater E60= 60 KW Heater E060= 60 KW Heater E200= 200 KW Heater E080= 80 KW Heater E240= 240 KW Heater E00= 00 KW Heater Code 35= BlowThru Coil Section/Drain Pan (RPS only) YYYY= No section Digits - 3 Cooling Type CYY= Cooling unit DYY= Drain Pan only- 48 section GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY) Code 36= BlowThru Cooling Coil (RPS only) YYYYYY= No Cooling Coil 4Z 08 3 D D= Lanced Aluminum C= Copper Fin 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch 2= 2 Fins-per-inch 0= 0 Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 37= N/A to RPS/RDT- Always YYYYYY Code 38= Attenuator Section (RPS only) Y= No section G= With 36 Std. Straight Attenuator K= With 36 Std. Straight Attenuator w/ Tedlar Coating H= With 60 Std. Straight Attenuator L= With 60 Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating F= Blank 48 Section E= Blank 24 Section Code 39= Final Filter Section (RPS only) Y= No section A= Flat filter section, 95% cartridge, 24/24 section J= Flat filter section, 95% cartridge, 24 section B= Staggered filter section, 95% cartridge, 24/48 section K= Staggered filter section, 95% cartridge, 48 section E= Flat filter section, 95% cartridge w/ Intersept, 24/24 section L= Flat filter section, 95% cartridge w/ Intersept, 24 section F= Staggered filter section, 95% cartridge w/ Intersept, 24/48 section M= Staggered filter section, 95% cartridge w/ Intersept, 48 section G= Flat filter section, 95% HEPA cartridge, 24/48 section N= Flat filter section, 95% HEPA cartridge, 48 section H= Flat filter section, 95% cartridge, 48/48 section Q= Blank- 24/24 section R= Blank- 24/48 section S= Blank- 24 section T= Blank- 48 section Code 40= Discharge Plenum BY= Bottom Discharge BB= Bottom Discharge w/ Burglar Bars BE= Bottom Discharge w/ Discharge Damper LY= Left Side Opposite Side RY= Right Side Drive Side Code 4= Out-of-Airstream Blank Access Section Y= None = 48/24 Blank Section only- out of airstream with light 2= 48 Blank Section only- out of airstream with light Code 42= Compressor Capacity Control M= Modulating Code 43= Condenser Options Digit : Air Coil M= 25mm Micro Channel Coil P= 25mm Electrofin Coated Micro Channel Coil T= 32mm Micro Channel Coil U= 22mm Electrofin Coated Micro Channel Coil Y= None Digit 2: Condenser Options G= Coil Guards, Steel S= Seal Tite Conduits B= G + S Y= None Code 44= Compressor Type V= Variable Speed Scroll W= Variable Speed Scroll w/ Line Reactor Code 45= Compressor Isolation = Resilient Rubber-in-Shear Code 46= Piping Options = Hot Gas Bypass, circuit # only 2= Hot Gas Bypass, cir. & 2 3= Replaceable Filter Drier Core 4= + 3 5= Y= None Code 47= Low Ambient Operation 2= SpeedTrol Standard Fans L= Low Ambient 4= Quiet Fan + SpeedTrol Code 48= IBC Seismic Construction Y= None A= ASCE 7-0 Wind Certification I= Seismic Construction J= IBC Seismic Construction- Category E/F Code 49= Fan Section Options A= SA Fan Belt Guard E= SA & RA Fan Section Light B= SA Fan Section Light F= D + E C= A + B Y= None D= SA & RA Fan Belt Guard Code 50= Blender Section Y= None L= Low CFM Blender, 48 Section H= High CFM Blender, 48 Section E= Blank 24 Section F= Blank 48 Section Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page

12 Nomenclature Unit Code Index, Continued Code 5= Draw=Thru Pre-Heat Section YYYYY= None EEEEEE= Blank 24 Section FFFFFF= Blank 48 Section W E 3 E Y= No Actuator E= Electric Actuator Y= No Valve 2= 2- Way Valve (ST) 3= 3- Way Valve (HW) Y= No Valve E=.25 Valve J= 3.00 Valve F=.50 Valve G= 2.00 Valve H= 2.50 Valve = 9 FPI Row (HW) OR 6 FPI Row (ST) 2= 2 FPI Row (ST) 3= 06 FPI 2 Row (ST) 4= 2 FPI 2 Row (ST) 22= 9 FPI 2 Row (HW) W= Hot Water Heat (HW) S= Steam Heat (ST) Code 52= Drain Pan/Humidifier Section (RPS only) YY= None DH= Humidifier w/ stainless steel Drain Pan 48 section DY= Stainless steel Drain Pan only, 48 section EE= Blank 24 Section FF= Blank 48 Section Code 53= Custom Specifications YY= None RR= B vintage replacement unit Code 54= Hot Gas/Liquid Subcool Reheat YY= None BM= BlowThru Modulating (includes SpeedTrol) ML= Modulating Liquid Subcool Reheat Circuits # & 2 BL= BlowThru Modulating, Hot Gas Circuit #2, AND Modulating Liquid Subcool Reheat Circuits # & 2 Code 55= Ultra High Efficiency Units YY= None HE= Ultra High Efficiency Unit (05D, 063D) Code 60= Miscellaneous Specials YY= None XX= Special Code 6= Packaging/ASHRAE Certification = Steel Skid 2= Consolidated Ship Code 62= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 63= Compressor Warranty A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special Code 64= Heat Exchanger Warranty Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 65= Unit Family 047C= 045D- 074D Code 66= Drain Connection Y= None L= Left Side (opposite drive side) R= Right Side (drive side) Code 67= ASHRAE Certification Y= None B= AHRI Certified C= AHRI Certified Code 68= Short Circuit Current Rating YY= None 0= 0 SCCR 22= 22 SCCR 65= 65 SCCR Code N/A to RPS/RDT- Always YYYYYYYY Code 56= Chicago Code/Refrigeration Service Valves YY= None CC= Chicago Code YV= Refrigeration Service Valves CV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS/RDT- Always YY Code 58= Return Air Fan Drive Selection A Service Factor/Pitch Type Required RPM A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 59= Supply Air Fan Drive Selection A Service Factor/Pitch Type Required RPM A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 2

13 Nomenclature Control & Sensor Location Diagrams Compressor VFD Condensor section OOE SV SC, 2 (optional) C, 2 (optional) SV9, SV0 Return air economizer Filter section Supply fan section FS (optional) Heat section DX section Discharge plenum section HTR-2, HTR3-4 (optional) SD2 (optional) C9 RAT LT (optional) S, REC OAE OAT PC7 EFT HL22 (optional) LT0 (optional) S0, R EC0 (optional) ACT3 PC5 ACT6 (optional) RAE (optional) RPS DAT ACT5 (optional) VM (optional) SD (optional) Filter section DX section Heat section C9 Compressor VFD Su pply fan discharge plenum section Condenser OOE section SV SC, 2 (optional) C, 2 (optional) SV9, SV0 Economizer return air HTR-2, U/U2 HTR3-4 (optional) DAT C9, 20 (optional) OAE LT0 (optional) S0, REC0 (optional) SD (optional) VM (optional) OOE SV RAT LT (optional) ACT3 ACT6 (optional) RAE S, REC (optional) SD2 (optional) PC5 RDT OAT FS (optional) Compressor Control Box Control Locations The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 3

14 Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT0, Actuator Motors, Exhaust Dampers Return Air Section ACT2, 3 Actuator Motors, Enthalpy Wheel Bypass Damper Energy Recovery Section AS Airflow Switch, Burner Blower Gas Heat Box BM Burner Blower Motor Furnace Section C- C4 Power Factor Capacitors, Compressors Condenser Section C0 Power Factor Capacitor, Supply Fan Supply Air Section C Capacitor, SpeedTrol Circuit # Cond. Bulkhead C20 Power Factor Capacitor, Return Fan Return Air Section C2 Capacitor, SpeedTrol Circuit #2 Cond. Bulkhead CB0 Circuit Breaker, Supply Fan Main Control Box CB20 Circuit Breaker, Return/Exhaust Fan Main Control Box CB60 Circuit Breaker, Energy Recovery Wheel Main Control Box CDS2 Discharge Thermostat VFD Compressor COMPR.- 4 Compressors Condenser Section CS, 2 Control Switches, Refrigeration Circuits Main Control Box DAT Discharge Air Temperature Sensor Discharge section DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS Disconnect, Total Unit or Condenser/Heat Main Control Box DS2 Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS6 Disconnect, Factory Powered Outlet Condenser Section EAT Exhaust Air Temperature Sensor Energy Recovery Section EFT Entering Fan Air Temperature Sensor Supply Fan Section ERM, 2 Energy Recovery Wheel Motors Energy Recovery Section EXPA- D MicroTech III Expansion Boards Main Control Box FA, B Fuses, Control Circuit Transformer, (T) Primary Main Control Box FC Fuse, Control Circuit Transformer, (T) Secondary Main Control Box F2 Fuse, Control Circuit Transformer, (T2) Primary Main Control Box F3 Fuse, Burner Blower Motor Main Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section FB2M Fuseblock, Inverter Compressor Main Control Box FB0 Fuseblock, Supply Air Fan Main Control Box FB, 2, 2, 22 Fuseblocks, SpeedTrol Main Control Box FB20 Fuseblock, Return Air Fan Main Control Box FB3-40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Box FB4-50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Box FB60 Fuseblock, Energy Recovery Wheel Main Control Box FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FP, 2 Frost Protection, Refrigeration Circuits Coil Section, Cool FS, 2 Freezestat Control Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Box GFR, 2 Ground Fault Relays Main Control Box GFS, 2 Ground Fault Sensors Main Control Box GFR4 Ground Fault Relay, Condenser Condenser Control Box Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 4

15 Electrical Legend Continued Schematic Sym. Description Location GFS4 Ground Fault Sensor, Condenser Condenser Control Box GRD Ground All Control Boxes GV Gas Valve, Pilot Furnace Section GV2 Gas Valve, Main/Safety Furnace Section GV3 Gas Valve, Redundant/Safety Furnace Section GV4-8 Gas Valve, Main, Hi-Turn Down Furnace Section HL- 0 High Limits, Power, Electric Heaters (Top Bank) Electric Heat Section HL- 20 High Limits, Power, Electric Heaters (Bottom Bank) Electric Heat Section HL22 High Limit, Gas Heat (Prefilters) Supply Air Section HL23 High Limit, Gas Heat (Final Filters) Final Filter Section HL3-40 High Limits, Control, Electric Heaters (Top Bank) Electric Heat Section HL4-50 High Limits, Control, Electric Heaters (Bottom Bank) Electric Heat Section HP- 4 High Pressure Controls, Refrigerant Cmpr./Press./Cond. Box HP5 High Pressure Control, Gas Furnace Section HS Heat Switch, Electric Shutdown Main Control Box HS3 Heat Switch, Electric Heat Deadfront Interlock Electric Heat Box HTR- 4 Crankcase Heaters On Compressors HUM Humidistat Sensor Energy Recovery Section IT Ignition Transformer Furnace Section LAT Temperature Sensor, Leaving Air Energy Recovery Section LP- 4 Low Pressure Controls, Refrigerant On Cmpr./Cond. Box LP5 Low Pressure Control, Gas Furnace Section LR0 Line Reactor, Supply Fan Inverter Bypass Box LR20 Line Reactor, Return/Exhaust Fan Inverter Bypass Box LR, 2 Line Reactors, Condenser Fan SpeedTrol Pressure Control Box LS, 2 Limit Switches, Low/High Fire Furnace Section LT0 Light, Supply Fan Supply Air Section LT Light, Return Fan Return Air Section LT2 Light, Heat Section Heat Section LT3 Light, Filter Section Filter Section LT4 Light, Final Filter Section Final Filter Section LT5 Light, Discharge Section Discharge Section LT6 Light, Blow-through Coil Section BlowThru Coil Section LT7 Light, Evaporator Coil Section Evaporator Coil Section LT8 Light, Preheat Section Preheat Section LT9 Light, Blank Section Blank Section LT20 Light, Blank/Empty Section Blank/Empty Section LT2 Light, Draw Thru Coil Section DrawThru Coil Section LT22 Light, Condenser Section Condenser Section M, 3, 5 Contactors, Compressors Main Control Box M0 Contactor, Supply Fan Main Control Box M- 8 Contactors, Condenser Fans, Circuit # Main Control Box M20 Contactor, Return Fan Main Control Box M2-28 Contactors, Condenser Fans, Circuit #2 Main Control Box M29 Contactor, Burner Motor Furnace Section M30 Contactor Reversing, Inverter Bypass, Supply Fan Inverter Bypass Box M3-39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Reversing, Inverter Bypass, Return Fan Inverter Bypass Box M4-50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M60, 6 Contactors, Energy Recovery Wheel Motor Main Control Box MCB Microtech III Control Board Main Control Box Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 5

16 Electrical Legend Continued Schematic Sym. Description Location MJ Mechanical Jumpers All Control Boxes MMP, 3, 5 Manual Motor Protectors, Compressors Main Control Box MMP0 Manual Motor Protector, Supply Fan Main Control Box MMP- 8 Manual Motor Protectors, Condenser Fans Ckt. Main Control Box MMP20 Manual Motor Protector, Return fan Main Control Box MMP2-28 Manual Motor Protectors, Condenser Fans Ckt. 2 Main Control Box MMP30 Manual Motor Protector, Inverter Bypass Supply Fan Inverter Bypass Box MMP40 Manual Motor Protector, Inverter Bypass Return Fan Inverter Bypass Box MMP5-53 Manual Motor Protectors, Exhaust Fan(s) Prop Exhaust Box MMP60, 6 Manual Motor Protector, Energy Recovery Wheel Main Control Box MP- 4 Motor Protectors, Compressors On Compressors OAE Enthalpy Control, Outside Air Economizer Section OAT Temperature Sensor, Outside Air Economizer Section OL6 Overload- Energy Recovery Wheel () Main Control Box PB, 2 Powerblock, Power Distribution Main Control Box PB3 Powerblock, Power Distribution, Electric Heat Electric Heat Section PB4 Powerblock, Power Distribution, Condenser Cond. Control Box PB9, 0 Powerblocks, Supply Fan Junction Box, Split Unit PB, 2 Powerblocks, Power Distribution Main Control Box PB9, 20 Powerblocks, Return/Exhaust Fan Junction Box, Split Unit PC5 Pressure Control, Clogged Filter Pre Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Section PT, 2 Pressure Transducers, SpeedTrol Pressure/Cond. Box PVM, 2 Phase Voltage Monitors Main Control Box R Relay, Cond. Fan SpeedTrol Inverter Enable Pressure/Cond. Box R7 Relay, Cond. Fan 2 SpeedTrol Inverter Enable Pressure/Cond. Ctrl. Box R20 Relay, Gas/Steam/Hot Water Furn./Main Ctrl. Box R2, 22 Relays, Gas Heat, 20: High Turndown Furn./Main Ctrl. Box R23 Relay, Gas Heat Furnace Section R24 Relay, Gas Heat Alarm Main Control Box R25 Relay, Gas Heat, Start Supply Fan Inverter Main Control Box R26 Relay, Isolation/Exhaust Dampers Main Control Box R28 Relay, Isolation Damper Safety Main Control Box R38-40 Relays, Compressor Inverter Heater & Fans Compressor Control Box R45 Relay, UV Lights Main Control Box RAE Enthalpy Sensor, Return Air Return Air Section RAT Temperature Sensor, Return Air Return Air Section REC Receptacle, Main Box Main Control Box REC2 Receptacle, Condenser Box Cond. Control Box REC3 Receptacle, Field Power, 5VAC Discharge Bulkhead REC0-23 Receptacles, Cabinet Sections Cabinet Sections RHB, 2 Interface Board, Modulating Hot Gas Reheat Main Control Box S Switch, System On/Off Main Control Box S3 Switch, Furnace On/Off Furnace Section S4 Switch, Inverter Bypass On/Off Main Control Box S40-45 Switches, Door Interlock, UV Lights Cabinet Sections SC Speed Control, Circuit # Cond. Bulkhead SC2 Speed Control, Circuit #2 Cond. Bulkhead SD Smoke Detector, Supply Air Discharge Section Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 6

17 Electrical Legend Continued Schematic Sym. Description Location SD2 Smoke Detector, Return Air Return Air Section SHS Sensor, Space Humidity Return Section (Field inst.) SPS, 2 Sensors, Static Pressure, Duct or Building Main Control Box SV, 2 Solenoid Valves, Liquid/Drop Condenser Section T Transformer, Main Control, Line/5VAC Main Control Box T2 Transformer, Control Input, 5/24VAC Main Control Box T3 Transformer, Control Output, 5/24VAC Main Control Box T6 Transformer, Factory Powered outlet, Line/5VAC Condenser Section T7 Transformer, Hot Gas Reheat, 5/24VAC Main Control Box T Transformer, SpeedTrol, Line/240VAC Condenser Section TB Terminal Block, Internal for Transformers Main Control Box TB2 Terminal Block, Field Main Control Box TB3 Terminal Block, Factory, 5/24VAC Main Control Box TB4 Terminal Block, Field, 5VAC Main Control Box TB7 Terminal Block, 5VAC Convenience Outlet Main Control Box TB Terminal Block, Heating Furn./Elect. Heat Ctrl. Box TB4 Terminal Block, Inverter Compressor Control Box Compressor Control Box TB25-28 Terminal Blocks, Split Unit Junction Box Split Unit Junction Box TB35-37 Terminal Blocks, Pressure Controls Pressure Control Box TD20 Time Delay, Return Air Fan Main Control Box TR, 2 Transducer, Pressure, SpeedTrol Main Control Box VFD/AFD2 Adjustable Frequency Drive, Inverter Compressor Compressor Control Box VFD/AFD0 Adjustable Frequency Drive, Supply Fan Draw thru/supply Section VFD/AFD, 2 Adjustable Frequency Drive, Cond. Fan SpeedTrol Pressure/Cond. Ctrl. Box VFD/AFD20 Adjustable Frequency Drive, Return/Exhaust Fan Dr. Thru/Ret./Exh. Section VFD/AFD60 Adjustable Frequency Drive, Energy Recovery Wheel Energy Recovery Section UV Ultra-Violet Light(s) Coil/Discharge Section VM Valve Motor #, Heating Furnace/Heating Section VM5 Valve Motor #5, Cooling Coil Section, Cooling VV Vent Valve, Gas Heat Furnace Section ZNT Sensor, Zone Temperature Field Installed Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 7

18 Section A- Outdoor/Return Air Section Notes Primary Codes that pertain: 9, 20, 2, 22, 58 Additional Codes that pertain: 06, 09, 4, 5, 6, 7, 23, 24, 33, 48, 49 Codes 9 and 20 determine the base section. Code 9 is the Return Air Plenum and determines if the unit has Back/Horizontal Return Air, Bottom Return Air, Left, or Right Side discharge. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 20= BE, DE, EE, FE, GE). The only case in which a Plenum is not required is when a 00% Outdoor Air Damper and Hood are ordered (Code 20= AE). For units with Heat/Energy Recovery (Code 20= 3E, 4E, 5E, 6E) see Section A2. Code 2 determines the Return Fan size and type. Code 22 determines the Return Fan Motor horsepower and type. Code 58 determines the drive selection. These codes only pertain to units with a 0-00% Economizer (Code 20= DE, EE, FE, GE). The Return Air Fan section parts, the fans, and the motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Return Fan motors range from 2-30 horsepower, and the Fan is a 40 single width Airfoil Wheel. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 09, unit voltage, is part of the Return Fan Motor part number identification. Codes 4 & 5 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4= 2, 4 there is a separate Inverter Section. If Code 4= Y, there are no Inverters. Code 5 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its own Control Box. Codes 4 and 5 DO NOT apply to this inverter.) For Return Air Section inverter part numbers, refer to Section F the Supply Air Section. Code 6 determines if the unit has a Smoke Detector located in the Return Air cabinet. If Code 6=, 3 a Smoke Detector (SD2) is present in the Return Air Section. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 23 indicates the presence of Plenum/Vestibule Lights, UV lights, 5V Service Outlet, and/or Intelligent Equipment. Code 24 indicates the presence of Exhaust Fans. Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for Gauge part number and description. Code 33 also indicates if the unit is California Title 24 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Light, Switch and Receptacle (Code 49= B, E), Fan Belt Guards (Code 49= D) OR both (Code 49= F). Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 8

19 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood Code 20= AE AND Code 9= YY No Return Air Plenum Air Flow Section B Ref. Part Part Qty. No. Description Number 4 Damper Assy- Complete Damper only Liner Panel- Hood Side Panel- Hood Side Panel- Hood Top Louver Channel- Support Channel- Support This Damper Assy. includes the Damper, Damper Linkage, and Actuator. For Damper Assy. components see the following page. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified. 2 Damper only, NO Actuator Linkage OR Actuator. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 9

20 Section A- Outdoor/Return Air Section 00% Outside Air Damper w/act3 Code 20= AE AND Code 9= YY 4 27 Motorized Linkage Detail: Ref. Part Part Qty. No. Description Number 4 Shaft- Linkage Adapter Plate- Crank Arm Blade- Damper Grille Stop-Anti Rotate, Damper Support- Damper Motor Linkage Bar Drive Tab Crank Arm- Damper Ball Joint- Damper Actuator- Motorized, 24V ACT Bushing- Linkage Bar, Nylon Bushing- Damper Blade, Nylon Gasket- Vinyl Gasket- Vinyl Plug- Damper End Plug- Damper End Plug- Damper End Bearing- Flange Sleeve Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 20

21 Section A- Outdoor/Return Air Section 0-30% Outside Air Section w/ ACT3: Code 20= BE 4 30 Linkage Detail Ref. Part Part Qty. No. Description Number Damper Assembly- Complete Damper only Blade- Damper Gasket- Vinyl Gasket- Vinyl Seal- End Grille Support- Motor Bar- Linkage Shaft- Linkage Louver Plug- End Plug- End Bushing- Damper Blade Bushing- Linkage Bar, Nylon Ball Joint- Damper Actuator- Motorized, 24V ACT Crank Arm- Damper Bushing- Actuator Channel Retainer Damper assy includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. 2 Damper only, NO Actuator Linkage OR Actuator. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 2

22 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Barometric Exhaust Damper Units without Return Air Fans Code 20= DE, EE, FE, GE AND Code 2= YYYY 2 Back Return (Code 9= HY) shown. Air Flow Ref. Part Part Qty. No. Description Number Economizer Damper w/ Actuator, 2 2 Exhaust Damper Assy. Powered (Code 20= EE, GE) Barometric (Code 20= DE, FE) Economizer detail two pages after next. 2 For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 22

23 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Barometric Exhaust Damper Units with 40 Return Air Fans Code 20= DE, EE, FE, GE Code 2= 40B, 40B2, 40B3 60 Bottom Return (Code 9= BY) shown (See Return Fan Detail) Air Flow (See Return Fan Detail) Ref. Part Part Qty. No. Description Number Economizer Damper w/actuator Code 20= DE, EE, FE, GE, 2 60 Exhaust Damper Assy. Powered Code 20= EE, GE Barometric Code 20= DE, FE Belt Guard Code 49= D, F Belt Guard Code 49= D, F Gasket Gasket Economizer detail on page after next. 2 For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 23

24 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Prop Exhaust Fan & Damper Code 20= HE, JE AND Code 24=, 2 Section Assembly Detail 2 fan arrangement shown (Code 24= 2) Fan Guard Ref. Part Part Qty. No. Description Number 420 Fan Assembly 208/230/ Fan Assembly Fan Guard Panel- Weather Hood Hood- Prop Exhaust N/S Grille Only- Prop Exhaust Hood N/S= Not Shown on diagram. See detail following Isolation Damper Detail. 2 Quantity may be one (Code 24= ) OR two (Code 24= 2). 3 Quantity is PER fan. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 24

25 Section A- Outdoor/Return Air Section 0-00% Economizer Damper w/ ACT3 Code 20= DE, EE, FE, GE, HE, JE Diagrams Linkage Detail Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 25

26 Section A- Outdoor/Return Air Section 0-00% Economizer Damper w/ ACT3 Code 20= DE, EE, FE, GE, HE, JE Components Ref. Part Part Qty. No. Description Number Damper Assy- Complete Damper Assembly Shaft Assembly Plate- Crank Arm Shaft- Linkage Channel- Support Blade- Damper Stop/Anti-Rotate- Damper Bar- Linkage Drive Tab- Linkage Bar Ball Joint- Damper Actuator- 24V ACT Bushing- Linkage Bar Bushing- Damper Blade Gasket- Vinyl Gasket- Vinyl End Plug- Damper End Plug- Damper End Plug- Damper Bushing- Actuator Channel- Actuator N/S Gasket- Neoprene N/S= Not Shown on Diagram. Damper Assy. includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. 2 Damper Assy. includes the Damper and Damper Linkage, but NO Actuator. 3 Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 26

27 Section A- Outdoor/Return Air Section California Title 24 Assembly Code 33= *F*** Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch Bracket, Mounting Switch Switch, Push Button SPDT Bushing, Conduit 3630 Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 27

28 Section A- Outdoor/Return Air Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE ACT6 Actuator Detail Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized Motor Mount Assembly Blade Assembly- Return, Angle- Linkage Angle- Blade Shaft- Damper Blade Shaft- Linkage Bearing- Flange, Nylon Actuator- Motorized, 24V ACT Crank Arm- Damper Ball Joint Bearing- Sleeve Gasket- Vinyl Bracket- Support Retainer- Actuator Bearing- Sleeve Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 28

29 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Code 20= HE, JE AND Code 24=, 2 420A 420 Fan Assembly Components 2 Fan Arrangement Shown (Code 24= 2) 54 5 B A 6C 6B 6D 6E 6F 6G 6H Lube Line Detail 53 Control Box (see following page 6I Voltage Ref. Sch. Part Part No. Sym. Description Number AFD20 Inverter see charts on following page A Resistor- Inverter B Jumper- Inverter B Fan Prop C Fan Shaft D Bearing E Fan Sheave F Bushing- Fan Sheave G Belt H Motor Sheave I Motor Motor Tube- Plastic Coupling- Tube 2.25 x.25 FPT Fitting- Grease Fan Assembly- Complete Fan Assembly- Complete A Damper- Backdraft Quantity= 2 when Inverter model 3500 (Code 5= G) is used. 2 Quantity shown is for fan (Code 24=). Quantities for 2 fan units (Code 24= 2): Ref. 5= 25 ; Ref. 53= 4; Ref. 54= 4. 3 Contact Daikin Applied. 4 Quantity is PER fan. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 29

30 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Code 20= HE, JE AND Code 24=, 2 Continued Inverter- Fan Units (Code 24= ) Voltage Code Inverter Model Part 5= Number A B MD MD G Q MD MD R VTAC VTAC S MD MD V 230V Inverter- 2 Fan Units (Code 24= 2) Voltage Code Inverter Model Part 5= Number A B MD MD G Q MD MD R VTAC VTAC S MD MD V 230V Prop Exhaust Fan Control Box OL5 OL52 M5 M52 2 Fan Unit shown Voltage Ref. Sch. Part Part No. Sym. Description Number 220 OL5, 52 Overload Overload Overload Overload M5, 52 Contactor 25A Contactor 6A Contactor 9A Contactor 7A V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 30

31 LH Louvered Door Assy Section Final Assembly Section A- Outdoor/Return Air Section Design Flow Detail Code 20= FE, GE, JE Louvered Door Assembly Detail RH Louvered Door Assy Design Flow Vane and Vane Bearings Detail Adjuster Control Assy Detail 30 Spring Detail Ref. Part Part Qty. No. Description Number Louver Panel Left Hand Door Louver Panel Right Hand Door Grille Gasket Gasket Potentiometer O-Ring- Potentiometer Panel- Vane Shaft- Upper Bearing- Lower Crank Arm Assy Left Hand Door Crank Arm Assy Right Hand Door Link Arm 2 20 Bearing Bearing Spring- Main.75 x Spring- Secondary.30 x N/S Leveling Kit- Design Flow Quantity is PER door. 2 P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 3

32 Section A- Outdoor/Return Air Section 40 Return Air Fan (Code 2= 40B*) Ref. Part Part Qty. No. Description Number Motor see tables one & two pages after next Fan Housing Assy- Inlet Funnel Inlet Funnel Wheel- Air Foil Fan, SI/SW Mount- Motor Shaft.937 Diameter Coupling /8 MPT Coupling- Reducer /4 X /8 FPT Tubing- Plastic Grease Fitting /8 MPS Bearing- Ball.937 bore Key- Wheel /2 X 5 / Key- Fan Sheave /2 X 4 / Mounting type, fourth digit: = RIS, 2= Spring, 3= Spring w/ Seismic Snubbers. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 32

33 Section A- Outdoor/Return Air Section Return Air Fan Mounts (Code 2= 40B*) Rubber Mounts Rubber Mounts (Code 2= 40B) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Channel- Mount Support Rubber Mount- Black , 30 Rubber Mount- Red Rubber Mount- Black Rubber Mount- Red Rubber Mount- Black Rubber Mount- Black All Nut All Screw All Nut- / All Screw- Cap, /2-3 X All Washer- Plain, / or 6 63 or or 64 Mounting Diagram Spring Mounts 2 62 or 62 Seismic strap used only when Code 2= 40B Spring Mounts (Code 2= 40B2) & Seismic Spring (40B3) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Mount Spring Code 2= 40* Seismic Code 2= 40* Spring Mount- Yellow , 5 Spring Mount- Yellow Spring Mount- Green Spring Mount- Dark Brown , 5, 20, 25 Spring Mount- Dark Brown Spring Mount- Green Spring Mount- Red Spring Mount- Yellow Spring Mount- Blue Spring Mount- Dark Brown Spring Mount- Yellow Spring Mount- Yellow , 30 Spring Mount- Blue All Nut Spring Code 2= 40* Seismic Code 2= 40* All Nut All Screw Spring Code 2= 40* Seismic Code 2= 40* Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 33

34 Section A- Outdoor/Return Air Section Return Air Fan Motors Standard Motors: Code 22= **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Motor Code 22= Voltage C22= *EY C22= *JY C22= *HY C22= *KY Mount C09= 2 2 G*Y 208/60/ H*Y 208/60/ J*Y 208/60/ K*Y 208/60/ L*Y 208/60/ M*Y 208/60/ N*Y 208/60/ P*Y 208/60/ Q*Y 208/60/ C09= 29 2 G*Y 230/60/ H*Y 230/60/ J*Y 230/60/ K*Y 230/60/ L*Y 230/60/ M*Y 230/60/ N*Y 230/60/ P*Y 230/60/ Q*Y 230/60/ C09= 27 2 G*Y 460/60/ H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ C09= 37 2 G*Y 575/60/ H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ Note that the Return Fan Motor Mounts listed are used ONLY in Heat Recovery units when Code 2= 40B* AND Code 20= 3*, 4*, 5*, 6*. See the 40 Return Fan Detail in Section A2- Outdoor/Return Air w/ Heat Recovery Section. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 34

35 Section A- Outdoor/Return Air Section Return Air Fan Motors Shaft Grounded Motors: Code 22= **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C22= **S Voltage C22= *JS C22= *KS C09= 2 2 G*S 208/60/ N/A 3 H*S 208/60/ J*S 208/60/ K*S 208/60/ L*S 208/60/ M*S 208/60/ N*S 208/60/ P*S 208/60/ Q*S 208/60/ C09= 29 2 G*S 230/60/ H*S 230/60/ J*S 230/60/ K*S 230/60/ L*S 230/60/ M*S 230/60/ N*S 230/60/ P*S 230/60/ Q*S 230/60/ C09= 27 2 G*S 460/60/ H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ C09= 37 2 G*S 575/60/ H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ N/A= Not Available. For Return Fan Motor Mounts used in Heat Recovery units (when Code 2= 40B* AND Code 20= 3*, 4*, 5*, 6*) refer to the previous page. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 35

36 Section A- Outdoor/Return Air Section Section Mounted Controls OAE, RAE, LT, S, REC Bottom Return Shown Code 9= BY, BE Economizer Damper 40 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Bottom Return Shown Code 9= BY, BE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Mount- RAE Enthalpy Control- RAE RAT- Outdoor Air Temperature Sensor 7 Ref. Part Part Qty. No. Description Number 7 Sensor- RAT Return Air Opening 30 Return Air Opening SD2- Return Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 30 Smoke Detector- SD Back Return Code 9= HY Bottom Return Code 9= BY, BE LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 36

37 Section A2- Outdoor/Return Air w/ Heat Recovery Section Notes Primary Codes that pertain: 9, 20, 2, 22, 24, 58 Additional Codes that pertain: 06, 09, 4, 5, 6, 7, 23, 48, 49 Codes 9 and 20 determine the base section. Code 9 is the Return Air Plenum; Code 20 determines the type of Outdoor Air/Heat Recovery control used. When Code 20= 3E, 5E the unit has a 6 Heat Recovery Wheel. If Code 20= 4E, 6E the unit has a 2 Heat Recovery Wheel. Codes 2, 22, and 58 determine the Return Air Fan, Fan Motor and drive selection. The fan section parts, the Fans, and the Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. The motors range from 2-30 horsepower, and the Fan is a 40 Single width Airfoil Wheel. Code 24 determines if the Heat Wheel has a Frost Protection Inverter (VFD/AFD60) mounted in the section. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 09, the voltage, is part of the Return Fan Motor part number identification. Codes 4 & 5 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4= 2, 4 there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the inverter vendor. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its own Control Box. Codes 4 and 5 DO NOT apply to this inverter.) For Return Air Section Inverter part numbers, refer to the Supply Air Section (Section F). Code 6 determines if a Smoke Detector is located in the Return Air Cabinet. If Code 6=, 3, a Smoke Detector (SD2) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 7= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 23 (Mid 202 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/ HGRH inverter brand specified, and/or the presence of Intelligent Equipment. Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for part number and description. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Belt Guard (Code 49= D), OR a Belt Guard and a Fan Section Light (Code 49= F). Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 37

38 Section A2- Outdoor/Return Air w/ Heat Recovery Section Cabinet Gaskets, Doors, Hardware, Exhaust Hoods Code 20= 3E, 4E, 5E, 6E Cabinet Gaskets, Doors and Exhaust Hoods (LH components shown) Hood Exhaust Hood- See Detail to Left Ref. Part Part Qty. No. Description Number 44 Hinge Door Door- Exhaust Door- Exhaust Door Door Door Gasket- Vinyl Gasket- Vinyl Gasket- Vinyl Damper- Back Draft x Panel- Hood Panel- Hood RH Panel- Hood LH Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 38

39 Section A2- Outdoor/Return Air w/ Heat Recovery Section Base Components, Hood, Dampers Outdoor Air Intake Hood Detail Code 20= 3E, 4E, 5E, 6E See Hood Detail to Left 60 Base Assembly A Ref. Part Part Qty. No. Description Number Fan Assembly 2 Damper- OA Low Leak w/ Actuator ACT3 2 2A Damper- RA Low Leak w/ Actuator ACT Channel- Fan Channel- Fan Panel- Outdoor Intake Hood, Top Panel- Outdoor Intake Hood, Side Panel- Outdoor Intake Hood, Side Louver- Outdoor Intake Hood Louver- Outdoor Intake Hood Louver- Outdoor Intake Hood Screen- Outdoor Intake Hood Wheel, Enthalpy- Heat Recovery 3 20 Filter Rack- Upper LH Filter Rack- Upper RH Filter Rack- Lower LH Filter Rack- Lower RH Filter- 30% 6 x 20 x Filter- 30% 6 x 25 x Stop- Filter Damper- L Bypass w/ Actuator ACT2, See detail on following page. 2 See detail following Fan Mount detail. 3 See detail following L Bypass Damper detail. 4 See detail following Low Leak Damper detail. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 39

40 Section A2- Outdoor/Return Air w/ Heat Recovery Section 40 Return Air Fan (Code 2= 40B*) Motor 490 Ref. Part Part Qty. No. Description Number 072 Inlet Funnel Bearing, Roller- Drive Side 2 3/ Bearing- Inlet Side 2 3/ Shaft, 2 3/ Key Fan Wheel Motor Mount See Return Air Fan Motor Section. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 40

41 Section A2- Outdoor/Return Air w/ Heat Recovery Section 40 Return Air Fan Fan Mounts (Code 2= 40B*) Rubber Mounts Rubber Mounts (Code 2= 40B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Rubber Mount- Red All Channel- Mount Support All Nut, Clinch All Screw, 3/8-6 x All Screw, 5/ All Nut- / All Washer- Plain, / All Screw, Cap Mounting Diagram Spring Mounts Seismic strap used only when Code 2= 40B Spring Mounts (Code 2= 40B2) & Seismic Spring (40B3) Ref. Fan Motor Part Part Qty. No. HP Description Number Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Dark Brown , 20 Spring Mount- Red Spring Mount- Tan Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Dark Brown All Mount Spring Code 2= 40B Seismic Code 2= 40B All Nut, Clinch All Screw, 3/8-6 x Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 4

42 Section A2- Outdoor/Return Air w/ Heat Recovery Section Low Leak Damper Detail (Ref. #2, 2A) with ACT3 (Outside Air) OR ACT4 (Return Air) MicroTech III Controls (Code 2= *E, *F, *W) ACT3 OR ACT4 Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator Complete Assy- Less Actuator Seal- End Stop- Damper End Plug Blade- Damper Actuator, 24V ACT3, End Plug End Plug Bushing- Linkage Bushing- Damper Blade Shaft- Drive N/S Gasket- Vinyl N/S Gasket- Vinyl N/S= Not Shown on diagram. NOTE- The drawing is a generic illustration of this damper type, and shows part location, but does not show the actual part quantities listed in the table. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 42

43 Section A2- Outdoor/Return Air w/ Heat Recovery Section Bypass L Type Damper Detail w/ ACT2 (Outside Air) OR ACT3 (Return Air) (Ref. # 230) MicroTech III Controls (Code 2= *E, *F, *W) Actuator Detail ACT2 OR ACT Ref. Part Part Qty. No. Description Number Complete Assembly w/ Actuator Complete Assembly w/o Actuator Blade- Damper Blade- Damper Linkage- Channel Gasket- Vinyl Gasket- Vinyl Gasket- Vinyl Plug, End- Damper Plug, End- Damper Stop- Damper Bushing- Damper Blade Bushing- Linkage Bar End Plug- Damper Lock Collar Bushing- Drive Shaft Actuator, 24V ACT2, Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 43

44 Section A2- Outdoor/Return Air w/ Heat Recovery Section Heat Recovery/Enthalpy Wheel Wheel, Motor, Drive Components, Seals Outdoor Air Out (Supply) Exhaust Air In (Return) Low Air Flow ERW (Code 20= 3E, 5E)- 6 Wheel Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 208/230/ Segmented Wheel Motor 208/230/ Sheave Bearing Shaft Belt N/S Inner Seal N/S Outer Seal N/S= Not Shown on diagram. Includes motor, shaft, belt etc. 2 If a replacement wheel is required, it is suggested that this part number be used. The segmented wheel ships disassembled which allows for easier shipping and installation. High Air Flow ERW (Code 20= 4E, 6E)- 2 Wheel Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 208/230/ Segmented Wheel Motor 208/230/ Sheave Bearing Shaft Belt N/S Inner Seal N/S Outer Seal Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 44

45 Section A2- Outdoor/Return Air w/ Heat Recovery Section AFD60 Frost Protection Inverter (Code 24= F) Heat Wheel 70 Voltage Ref. Sch. Part Part No. Sym. Description Number 70 Code 23= **A** VFD60 Inverter Inverter Inverter Code 23= **B** VFD60 Inverter Inverter Inverter Code 23= **Q** VFD60 Inverter Inverter Inverter For the fusing for VFD60, refer to the "Energy Recovery Wheel Contactors, MMPs, & Fusing 04/3 & Later" page in Section N. 2 The replacement VFD Keypad is p/n V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 45

46 Section A2- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls OAE, RAE, RAT, EAT, LAT Economizer Damper 40 OAE- Mechanical Enthalpy (Code 7= Y*) Bottom Return Shown Code 9= BY, BE 4 Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Bottom Return Shown Code 9= BY, BE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy Control- OAE Mount- RAE Enthalpy Control- RAE RA Opening 84 Deck Panel 200 RAT- Outdoor Air Temperature Sensor Ref. Part Part Qty. No. Description Number 84 Support- RAT RA Sensor- RAT EAT- Outdoor Air Temperature Sensor Return Fan Ref. Part Part Qty. No. Description Number 422 Support- EAT RA Sensor- EAT LAT- Leaving Air Temperature Sensor Ref. Part Part Qty. No. Description Number 582 Support- LAT Sensor- LAT Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 46

47 Section A2- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls SD2, HUM, LT, S, REC Heat Wheel RA Opening SD2- Return Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 227 Support- SD Smoke Detector- SD RA Opening RAT Deck Panel HUM- Humidistat (units with frost protection) Code 24= F Ref. Part Part Qty. No. Description Number 596 Support- HUM 2/6 & Earlier 0780 /7 & Later Humidistat- HUM 2/6 & Earlier /7 & Later This is the duct mounted Humidistat. If a unit has a wall mounted Humidistat use p/n LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 47

48 Section B- DrawThru Filter/Blank Section Notes Primary Codes that pertain: 25, 33, 50 Additional Codes that pertain: 06, 9, 20 Code 25 determines the section s characteristics. If the first digit of Code 25= A, G the Filters are in an angular rack, if the first digit = F the Filters are in a flat rack, or if the first digit = L, S the filters are in a staggered rack. If the second digit = B there are 30% eff. throwaway filters; if C there are 30% eff. throwaway filters with Antimicrobial Intersept; if H there are 85% throwaway filters. If the second digit = D there are 65% eff. filters, if E there are 95% eff. filters, and if G there are 95% eff. filters with Antimicrobial Intersept. If the second digit = Y there is no filter media specified. If Code 25 = BY, EY there is a Blank/Empty section. Code 33 indicates the presence of a Magnehelic/Differential Filter gauge. Code 50 indicates the presence of an Air Blender. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank Access Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Codes 9 and 20 determine Return Air section characteristics which has an effect on the final assembly panels. Section Mounted Controls PC5, LT3, S3, REC3 Controls PC5 Ref. Part Part Qty. No. Description Number 65 Pressure Control- PC LT3- Filter Section Light/S3- Filter Section Light Switch/REC3- Filter Section Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 48

49 Section B- DrawThru Filter/Blank Section Filters Typical Angular Filter Section Shown Code 25= A* Ref. Part Code Part Qty. No. Description 25= Number Angular Filter Section (Code 25= A*, D*, E*) N/S Filter 30% Pleated, 6 x 25 x 2" MERV 8 *B % Pleated, 6 x 25 x 2" w/ Intersept MERV 8 *C % Disposable, 6 x 25 x 2 MERV 3 *H N/S Filter 30% Pleated, 6 x 20 x 2 MERV 8 *B % Disposable, 6 x 20 x 2 w/ Intersept MERV 8 *C % Disposable, 6 x 20 x 2 MERV 3 *H N/S Media Filler Piece ALL N/S Angle Assembly 2 ALL Flat Filter Section (Code 25= F*, G*, H*) N/S Filter, Cartridge 65% Cartridge, 24 x 24 x 2" MERV *D % Cartridge, 24 x 24 x 2" MERV 4 *E % Cartridge, 24 x 24 x 2" w/ Intersept MERV 4 *G % Disposable, 24 x 24 x 2 MERV 3 *H Gasket, Cartridge 5/8 x /6 x 24 ALL N/S Filter, Cartridge 65% Cartridge, 2 x 24 x 2" MERV *D % Cartridge, 2 x 24 x 2" MERV 4 *E % Cartridge, 2 x 24 x 2" w/ Intersept MERV 4 *G % Disposable, 2 x 24 x 2 MERV 3 *H Gasket, Cartridge 5/8 x /6 x 2 ALL N/S Pre Filter, 24 x 24 x 2 ALL N/S Pre Filter, 2 x 24 x 2 ALL Staggered Filter Section (Code 25= L*, S*, T*, V*) 65% Cartridge, 24 x 24 x 2 MERV *D % Cartridge, 24 x 24 x 2 MERV 4 *E % Cartridge, 24 x 24 x 2 w/ Intersept MERV 4 *G % Disposable, 24 x 24 x 2 MERV 3 *H Gasket, Cartridge 5/8 x /6 x 2 ALL N/S Filter, Cartridge 65% Cartridge, 2 x 24 x 2 MERV *D % Cartridge, 2 x 24 x 2 MERV 4 *E % Cartridge, 2 x 24 x 2 w/ Intersept MERV 4 *G % Disposable, 2 x 24 x 2 MERV 3 *H Gasket, Cartridge 5/8 x /6 x 2 ALL N/S Pre Filter, 24 x 24 x 2 ALL N/S Pre Filter, 2 x 24 x 2 ALL Note that MERV ratings may change during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. 2 Optional. Angle is mounted on leaving air side. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 49

50 Section B- DrawThru Filter/Blank Section Air Blender Section Components, & Magnehelic/Differential Pressure Gauge Air Blender Section Components (Code 50= L, H) 75 Ref. Part Code 50= Part Qty. No. Description Number 65 Panel- Access All Air Blender Low CFM L High CFM H Plate- Econo. Linkage Access All Magnehelic/Differential Pressure Gauge (Code 33= A****, B****, C****) 3396 Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0-3 WC Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 50

51 Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes Primary Codes that pertain: 26, 4, 5 Additional Codes that pertain: 06 Code 26 determines if a section is installed and if so, the size of the section. If Code 26= E there is a 24 Blank/ Empty section; if Code 26= F there is a Blank 48 section; if Code 26= Y, there is no section. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4=, 2, 4 there is a separate Inverter Section. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4= Y, there are no inverters. Code 5 identifies the inverter brand supplied. All components pertaining to the inverters are listed in the Supply Air Section (Section F). Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank/Empty Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Return Air Inverter (AFD20) Supply Air Inverter (AFD0) Section Mounted Controls LT2, S2, REC LT2- DT Access Section Light/S2- DT Access Section Light Switch/REC2- DT Access Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 5

52 Section D- DrawThru Cooling Section Notes Primary Codes that pertain: 03, 27, 28 Additional Codes that pertain: 06 Code 03 determines the DX cooling coil size. If Code 03= S there is a small face area coil in a 24 section; and if Code 03= L there is a large face area coil in a 48 section. Code 27 determines if there is a Section D. If Code 27= YYYY, then there is no section (for RPS units this indicates that the cooling coil is in the BlowThru position. RDT units always have a section D). If the first three digits of Code 27= DYY then the section contains only a drain pan in a 48 section. If the first three digits of Code 27= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 27= S, the Drain Pan is stainless steel, P in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 27= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 27= L, T, then the first three digits of Code 27 must equal DYY. Code 28 will apply only if Code 27= CYYY OR CYYS, and determines the DrawThru Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. NOTE: The drawings and components listed in this section also apply to Section I BlowThru Cooling Section- RPS units. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 52

53 Section D- DrawThru Cooling Section Evaporator Coils, Drain Pans, Gasketing, 2 24 Section, Small Face Coils (Code 03= S) Small Face Area Coil 24 Section Code 03= S Ref. Part Part Qty. No. Description Number 3 Coil Contact Daikin Applied 0 Drain Pan Galvanized C27= CYYY Stainless C27= CYYS Pan- Auxiliary Gasket Gasket Section, Large Face Coils (Code 03= L) Unit Sizes only Large Face Area Coil 48 Section Code 03= L Ref. Part Part Qty. No. Description Number 3 Coil- Lower Contact Daikin Applied 4 Coil- Upper Contact Daikin Applied 0 Drain Pan Galvanized C27= CYYY Stainless C27= CYYS Drain Pan Galvanized C27= CYYY Stainless C27= CYYS Pan- Liner Pan- Auxiliary Gasket Gasket Gasket For Drain Pans and components when Code 27= GYY* AND/OR Code 27= ***L, ***T contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 2 For BlowThru units (Code 35 AND Code 36 CANNOT be all Ys) substitute Code 35 for Code 27. BlowThru and DrawThru Cooling sections use the SAME parts, just the coding is different. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 53

54 Section E- Spacer Section (RPS) Notes Primary Codes that pertain: 30 Additional Codes that pertain: 06 For RPS units Code 30 is normally YYYYYY. If Code 26= EEEEEE there is a 24 Blank/Empty section; if Code 26= FFFFFF then there is a 48 Blank/Empty section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48 Spacer Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Section Mounted Controls LT8, REC8, S8- Section Mounted Light LT8- Spacer Section Light/S8- Spacer Section Light Switch/REC8- Spacer Section Receptacle Ref. Part Part Qty. No. Description Number 284 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Primary Codes that pertain: 04, 30 Additional Codes that pertain: 06 Section E- DrawThru Heat Section (RDT) Notes Code 04 determines what type of heat has been specified. DrawThru Heat units normally are hydronically heated with Steam (Code 04= S) OR Hot Water (Code 04= W). NOTE: There are some DrawThru Electric Heat RDT units. See Section G [Blow Thru Heat] for all Electric Heat components. Code 30 determines the Hydronic Heating Coil and associated characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 54

55 Section E- DrawThru Heat Section RDT Units Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM) (Code 30 first 3 digits = S, S2, S3, S4, W, W22) Coil Location Mixing Valve Detail (HW shown) Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30= Type Height Number 2 Steam Coil- Bottom S*** 5JA060H Steam Coil- Bottom S2*** 5JA20H Steam Coil- Bottom S3*** 5JA0602C Steam Coil- Bottom S4*** 5JA202C HW Coil- Bottom W*** 5WH090H HW Coil- Bottom W22*** 5WS0902C Steam Coil- Top S*** 5JA060H Steam Coil- Top S2*** 5JA20H Steam Coil- Top S3*** 5JA0602C Steam Coil- Top S4*** 5JA202C HW Coil- Top W*** 5WH090H HW Coil- Top W22*** 5WS0902C N/S Valve, 2 Way Steam w/ Act S**E2E 5JA All S**F2E 5JA All S**G2E 5JA All S**H2E 5JA All VM Actuator- 24V, Valve W****E All All Actuator- 24V, Valve W****E All All Valve, 3 Way HW w/ Actuator.25 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All W**H3E 5WH, 5WS All W**J3E 5WH, 5WS All N/S= Not shown on diagram. Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. 2 Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 55

56 Section F- Supply Air Section Notes Primary Codes that pertain: 3, 32, 59, 08, 4, 5, 40, 49 Additional Codes that pertain: 04, 06, 6, 7, 23, 33, 34 Code 3 determines the Supply Fan size and type, Code 32 determines the Supply Fan Motor horsepower and type, and Code 59 determines the drive selection. Supply Air Fan Section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 08 determines the location of the unit s Main Control Box. Note that RDT units normally have Main Control Boxes located in the Supply Air Section. Codes 4 & 5 determine if the unit has inverter(s), and if so where they are installed. If Code 4= Y, there are no inverters. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4=, 2, 4, there is a separate Inverter Section. Code 5 specifies the inverter brand. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its own Control Box. Codes 4 and 5 DO NOT apply to this inverter.) Code 40 determines the Discharge Plenum configuration. The Discharge Plenum is located in Section F when the section is bolted directly to the condenser (Section M). RDT units always have the Discharge Plenum located in Section F. If Code 40= BE, there is an Isolation Damper with actuator ACT5. This damper is detailed in Section K. Code 49 determines if the Supply Air cabinet has a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), OR both (Code 49= C, F). Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, the location of the Discharge Plenum, as well as the section installed controls. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 6 determines if a Smoke Detector is located in the Supply Air Cabinet. If Code 6= 2, 3, a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 7= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 7 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection. Code 23 indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 5V Service Outlet, and/ or Intelligent Equipment. Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 23= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 56

57 Section F- Supply Air Section Air Foil Fan- Double Width- RPS Units (Code 3= 27A*, 30A*, 33A*) 5 7 2A B Ref. Part Part Fan Size No Description Number Motor- see Supply Air Fan Motor Section 2 Housing Assy A Inlet Funnel Only B Cut Off Plate Only Housing Assy A Inlet Funnel Only B Cut Off Plate Only Housing Assy A Inlet Funnel Only B Cut Off Plate Only Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Screw Adjust Assembly Shaft Diameter Shaft Diameter Shaft Diameter Motor Mount Assembly Angle- Motor Mount Holddown Angle, Clamping Key- Fan 9.25 Long X /2 Diameter Key- Fan 9.25 Long X 5/8 Diameter Key- Fan 4.75 Long X 5/8 Diameter Key- Sheave 6.50 Long X /2 Diameter Key- Sheave 6.50 Long X 5/8 Diameter Bearing- Ball Bearing- Ball Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 57

58 Section F- Supply Air Section Air Foil Fan- Single Width- RDT Units Code 3= 40B, 40B2, 40B3, 44B, 44B2, 44B Ref. Part Part Fan Size No. Description Number Motor- see Supply Air Fan Motor Section 3 Wheel, Fan- Single Inlet/Single Width Wheel, Fan- Single Inlet/Single Width Screw Adjust Assembly Shaft Shaft Mount Assembly-Motor Angle -Motor Mount Angle, Clamping Bearing- Ball Bearing- Ball Key- Fan 4.25 Long X /2 Diameter Key- Fan 6.50 Long X 5/8 Diameter Key- Fan 5.50 Long X /2 Diameter Key- Fan 5.50 Long X 5/8 Diameter Tubing- Plastic Tubing- Plastic Inlet Funnel Assembly Inlet Funnel Assembly Fitting- /8 MPT Fitting, Reducer- /4 OD X /8 FPT Fitting Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 58

59 Section F- Supply Air Section Fan Mounts- 27 Airfoil Double Width Fan Code 3= 27A, 27A2, 27A Rubber Mounts Rubber Mounts (Code 3= 27A) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black , 5, 0 Rubber Mount- Black , 5-50 Rubber Mount- Red , 5-30 Rubber Mount- Black , 40, 50 Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /2-3 X All Washer- Plain, / or 6 Mount Locations 63 or or or 2 Spring Mounts Seismic strap used only when Code 3= 27A Spring Mounts (Code 3= 27A2) AND Seismic Spring (Code 3= 27A3) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Mount Spring Code 3= 27A Seismic Code 3= 27A Spring Mount- Green Spring Mount- Dark Brown , 50 Spring Mount- Red All Spring Mount- Green Spring Mount- Green , 0 Spring Mount- Dark Brown Spring Mount- Red , 50 Spring Mount- Tan All Spring Mount- Dark Brown All Nut Spring Code 3= 27A Seismic Code 3= 27A All Nut All Screw Spring Code 3= 27A Seismic Code 3= 27A N/S All Shim Code 3= 27A N/S= Not shown on diagram. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 59

60 Section F- Supply Air Section Fan Mounts- 30 Airfoil Double Width Fan Code 3= 30A, 30A2, 30A Rubber Mounts Rubber Mounts (Code 3= 30A) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Channel- Mount Support , 5 Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Red , 50 Rubber Mount- Green Rubber Mount- Black Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /2-3 X All Washer- Plain, / or 6 Mount Locations 63 or or or Spring Mounts Seismic strap used only when Code 3= 30A Spring Mounts (Code 3= 30A2) AND Seismic Spring (Code 3= 30A3) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Mount Spring Code 3= 30A Seismic Code 3= 30A Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red All Spring Mount- Green , 7.5 Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Tan All Spring Mount- Dark Brown All Nut Spring Code 3= 30A Seismic Code 3= 30A All Nut All Screw Spring Code 3= 30A Seismic Code 3= 30A Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 60

61 Section F- Supply Air Section Fan Mounts- 33 Airfoil Double Width Fan Code 3= 33A, 33A2, 33A Rubber Mounts Rubber Mounts (Code 3= 33A) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red , 5 Rubber Mount- Red Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /2-3 X All Washer- Plain, / or 6 Mount Locations 63 or or or 2 Spring Mounts Seismic strap used only when Code 3= 33A Spring Mounts (Code 3= 33A2) AND Seismic Spring (Code 3= 33A3) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Mount Spring Code 3= 33A Seismic Code 3= 33A Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Tan All Spring Mount- Green , 7.5 Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Tan All Spring Mount- Dark Brown All Nut Spring Code 3= 33A Seismic Code 3= 33A All Nut All Screw Spring Code 3= 33A Seismic Code 3= 33A Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 6

62 Section F- Supply Air Section Fan Mounts- 40 AFSW- RDT Units Code 3= 40B, 40B2, 40B Rubber Mounts Rubber Mounts (Code 3= 40B) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black All Nut All Screw All Nut- / All Screw- Cap, /2-3 X All Washer- Plain, / Mount Locations 62 or 62 6 or 6 64 or or Spring Mounts Seismic strap used only when Code 3= 40B Spring Mounts (Code 3= 40B2) AND Seismic Spring (Code 3= 40B3) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Mount Spring Code 3= 40B Seismic Code 3= 40B Spring Mount- Green Spring Mount- Dark Brown , 25, 40, 50 Spring Mount- Yellow , 30 Spring Mount- Dark Brown Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Green Spring Mount- Red , 50 Spring Mount- Dark Brown All Nut Spring Code 3= 40B Seismic Code 3= 40B All Nut All Screw Spring Code 3= 40B Seismic Code 3= 40B Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 62

63 Section F- Supply Air Section Fan Mounts- 44 AFSW- RDT Units Code 3= 44B, 44B2, 44B Rubber Mounts Rubber Mounts (Code 3= 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Red Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /2-3 X All Washer- Plain, / Mount Locations 62 or 62 6 or 6 64 or or Spring Mounts Seismic strap used only when Code 3= 44B Spring Mounts (Code 3= 44B2) AND Seismic Spring (Code 3= 44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number 2 All Mount Spring Code 3= 44B Seismic Code 3= 44B Spring Mount- Green Spring Mount- Dark Brown All Spring Mount- Dark Brown Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red All Spring Mount- Red All Nut Spring Code 3= 44B Seismic Code 3= 44B All Nut All Screw Spring Code 3= 44B Seismic Code 3= 44B Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 63

64 Section F- Supply Air Section Supply Air Fan Motors Standard Motors: Code 32= **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Code 32= Voltage C32= *EY C32= *JY C32= *HY C32= *KY C09= 2 3 H*Y 208/60/ J*Y 208/60/ K*Y 208/60/ L*Y 208/60/ M*Y 208/60/ N*Y 208/60/ P*Y 208/60/ Q*Y 208/60/ R*Y 208/60/ S*Y 208/60/ C09= 29 3 H*Y 230/60/ J*Y 230/60/ K*Y 230/60/ L*Y 230/60/ M*Y 230/60/ N*Y 230/60/ P*Y 230/60/ Q*Y 230/60/ R*Y 230/60/ S*Y 230/60/ C09= 27 3 H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ R*Y 460/60/ S*Y 460/60/ C09= 37 3 H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ R*Y 575/60/ S*Y 575/60/ Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 64

65 Section F- Supply Air Section Supply Air Fan Motors Shaft Grounded Motors: Code 32= **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C32= **S Voltage C32= *JS C32= *KS C09= 2 3 H*S 208/60/ J*S 208/60/ K*S 208/60/ L*S 208/60/ M*S 208/60/ N*S 208/60/ P*S 208/60/ Q*S 208/60/ R*S 208/60/ S*S 208/60/ C09= 29 3 H*S 230/60/ J*S 230/60/ K*S 230/60/ L*S 230/60/ M*S 230/60/ N*S 230/60/ P*S 230/60/ Q*S 230/60/ R*S 230/60/ S*S 230/60/ C09= 27 3 H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ R*S 460/60/ S*S 460/60/ C09= 37 3 H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ Q*S 575/60/ R*S 575/60/ S*S 575/60/ Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 65

66 4 40 Section F- Supply Air Section Belt Guards Code 49= A, C, D, F Air Foil Double Width (AFDW) Ref. Part Part Fan Size No. Description Number Grille Assembly Grille Assembly Grille Assembly Belt Guard Assembly Belt Guard Assembly Belt Guard Assembly Air Foil Single Width (AFSW) with Side Discharge (Code 40= H), Main Control Box (Code 08= S, F) The Main Control Box is mounted in this section on RDT units. Air Foil Single Width (AFSW) with Side Discharge (Code 40= S), No Control Box (Code 08= P, D) RPS units (Main Control Box is mounted in the Discharge Plenum Section K) Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= G), Main Control Box (Code 08= S, F) The Main Control Box is mounted in this section on RDT units. 83 Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= B), No Control Box (Code 08= P, D, Y) RPS units (Main Control Box is mounted in the Discharge Plenum Section K) Ref. Part Part Fan Size No. Description Number Grille Assy Grille Assy Grille Assy Grille Assy Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 66

67 Section F- Supply Air Section Inverters & Inverter Bypass Control Box Motor HP 2-5 (Code 22= G**, H**, J**; OR Code 32= H**, J**) MMP30 (Supply) MMP40 (Return) 7 72 LR0 (Supply) LR20 (Return) Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box shown. Phase Barrier (Code 4= 3, 5, 8) Front Mtd. Two boxes installed if Code 4= 5 Aux. Contact 70B 70A MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) Link 70C 72 Contactor MMP30/40 & M30/40 Link Detail 2 HP Motor- All Voltages 3, 5 HP Motors- 460/ Link 70C 72 72A Spacer Contactor MMP30/40 & M30/40 Link Detail 3, 5 HP Motors- 208/230V Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 20 Inverter- see Inverter section 208V 230V 208V 230V 208V 230V 50 Gasket MMP30, 40 Motor Protector A Phase Barrier B Aux. Contact C Link LR0, 20 Line Reactor- see page after Inverters 72 M30B, I Contactor M40B, I A Spacer Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 67

68 Section F- Supply Air Section Inverters & Inverter Bypass Control Box Motor HP (Code 22 OR Code 32= K**, L**, M**, N**, P**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) LR0 (Supply) 7 70 LR20 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 5, 8) Two boxes installed if C4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Link 70C 72 Link 70C 72A Spacer Contactor 72 Contactor MMP30/40 & M30/40 Link Detail 7.5 HP Motors- Front Mtd. Aux. Contact 70B Link 70C 72 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 208/230V 5, 20 HP Motors- 20 HP Motors- 25 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 7.5 HP Motors- 208/230/ 0, 5 HP Motors- Phase Barrier 70A Front Mtd. Aux. Contact 70B Link 70C 72 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 20, 25 HP Motors- 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 68

69 Section F- Supply Air Section Inverters & Inverter Bypass Control Box Motor HP (Code 22 OR Code 32= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 20 Inverter- see Inverter section 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 50 Gasket MMP30,40 Motor Protector A Phase Barrier B Contact- Auxiliary C Link LR0, 20 Line Reactor- see page after Inverters 72 M30B, I M40B, I Contactor 9A A A A A A A A A Spacer Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 69

70 Section F- Supply Air Section Inverters & Inverter Bypass Control Box Motor HP (Code 22= Q** OR Code 32= Q**, R**, S**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) LR0 (Supply) 7 70 LR20 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code 4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Front Mtd. Aux. Contact 70B MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Link 70C Link 70C Contactor Contactor MMP30/40 & M30/40 Link Detail 30 HP Motors- 460/ 40 HP Motors- Contactors 72 MMP30/40 & M30/40 Link Detail 30 HP Motors- 208/230V 40 HP Motors- 50 HP Motors- 460/ Overload 78 Interlock 79 MMP30/40 & M30/40 Link Detail 40, 50 HP Motors- 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 70

71 Section F- Supply Air Section Inverters & Inverter Bypass Control Box Motor HP (Code 22= Q** OR Code 32= Q**, R**, S**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 20 Inverter- see next page 208V 230V 208V 230V 208V 230V 50 Gasket MMP30 Motor Protector MMP A A A A A A Phase Barrier B Contact- Auxiliary C Link LR0,20 Line Reactor- see page after Inverters 72 M30B,I Contactor 50A M40B,I 5A A A A A A OL30 Overload A OL A Mechanical Interlink N/S CB30, 40 Circuit Breaker 50A N/S= Not Shown on Diagram. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 7

72 Section F- Supply Air Section Inverters Code 5= R Motor Horsepower /230V Part Number /230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 72

73 Section F- Supply Air Section Inverters, Continued Code 5= A 208/230V Motor Horsepower 2, /230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Part Number The replacement VFD Keypad Display is p/n Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 73

74 Section F- Supply Air Section Inverters, Continued Code 5= G Motor Horsepower Part Number V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V Motor Horsepower Part Number V 230V 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 74

75 Section F- Supply Air Section Inverters, Continued Code 5= S, Q 208/230V Motor Horsepower /230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Part Number , , , , , , , The Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The Lonworks communication card is p/n All other communication cards are integral to the VFD and are not available separately. 2 MD3 Remote Keypad p/n is MD6 Remote Keypad p/n is plus Mount p/n For units with an MD3 Inverter and Motor under 25 HP a Line Reactor will be installed regardless of whether one is specified in Code 7 (see nomenclature page). See one page after next for Line Reactor part numbers. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 75

76 Section F- Supply Air Section Inverters, Continued Code 5= B (MD4, MD5) 208/230V Motor Horsepower /230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Part Number The replacement VFD Keypad Display is p/n /230V 208/230V 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 76

77 Section F- Supply Air Section Line Reactors 208V/230V Motor Horsepower V/230V 208V/230V 208V/230V 208V/230V 208V/230V 208V/230V 208V/230V 208V/230V 208V/230V 208V/230V Part Number Line Reactors are used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7,, Y8; except for MD3 Inverters (Code 5= S, Q ) 2-20 HP. These will always have a Line Reactor installed regardless of Code 7. 2 These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 77

78 Section F- Supply Air Section Section Mounted Controls PC7, HL22, LT0, S0, REC0, UV Lights PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket Pressure Control- PC Pneumatic Fitting HL22- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 67 T-stat- HL22 Hi Limit LT0- Supply Fan Light/S0- Supply Fan Light Switch/REC0- Supply Fan Receptacle Code 49= B, E Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC UV Lights Code 7= C thru C8, Y thru Y8 Ref. Part Part Qty. No. Description Number 98 Light Fixture- 8 Bulb Light Fixture- 24 Bulb Light Fixture- 36 Bulb Bulb/Lamp, UV Bulb/Lamp, UV Bulb/Lamp, UV Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 78

79 Section F- Supply Air Section Section Mounted Controls MAT, EFT, SAT, DAT, OAT, SD 5 Mixed Air Temperature Sensor- MAT OR Entering Fan Temperature Sensor- EFT Ref. Part Part Qty. No. Description Number 5 EFT/MAT Temp. Sensor EFT Supply Air Temperature Sensor- SAT OR Discharge Air Temperature Sensor- DAT 8 Ref. Part Part Qty. No. Description Number 8 SAT/DAT Temp. Sensor DAT 7 Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 OAT Temp. Sensor OAT Smoke Detector Detail 5 50 Smoke Detector- SD Code 6= 2, 3 Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD Sensing Tube Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 79

80 Section F- Supply Air Section Section Mounted Controls SCB- Split Junction Box (Code 05= F) TB25, TB27, TB28, PB0, PB9, PB20, PB9 TB28 TB27 TB25 PB 9 PB 20 PB 9 PB 0 Motor HP , 50 Sch. Part Part Sym. Description Number Terminal Blocks TB25 Terminal Block- SCB TB27 Terminal Block- SCB TB28 Terminal Block- SCB PB0 Power Block- Supply Fan 95A, 600V, 3P PB9 Power Block- Supply Fan 95A, 600V, 3P PB20 Power Block- Return Fan 95A, 600V, 3P PB9 Power Block- Return Fan 95A, 600V, 3P Only used when the unit has a supply fan inverter OR an Economizer with a Power Closure Exhaust Damper. 208V 230V 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 80

81 Section G- BlowThru Heat Section Notes Primary Codes that pertain: 04, 34 Additional Codes that pertain: 06, 07, 09, 2, 3 This section is divided into four subsections:. Blank/Empty section; 2. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat. Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section s characteristics. If Code 04= Y, and Code 34= YYYYYY there is no section. If Code 04= Y and Code 34= BBBBBB, then there is a 48 Blank Access Section installed. Otherwise, see the Nomenclature, Unit Code Index section for specific heat section definitions. Code 06 determines the insulation and liners and will affect the Top Panel, Uprights, and Door Assembly part numbers. For sheet metal components that make up the BlowThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is ETA/MEA approved (USA) OR ETL approved (Canada). Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls. Code 2 determines the Control type and will affect the Gas Heat Actuator. Code 3 is the Supply Fan size, and affects the heat section s Diffusers. Option : Blank Section Code 34= BBBBBB AND Code 04= Y Diffuser 2 Ref. Part Part Qty. No. Description Number 2 Diffuser 27 Supply Fan Code 3= 27** Supply Fan Code 3= 30** Supply Fan Code 3= 33** Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 8

82 Section G- BlowThru Heat Section Option 2: Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM) Code 34 first 3 digits = S, S2, S3, S4, W, W22 Diffuser 2 Coil Location Mixing Valve Detail (HW shown) Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number 2 Steam Heat Coil- Bottom S*** 5JA060H Steam Heat Coil- Bottom S2*** 5JA20H Steam Heat Coil- Bottom S3*** 5JA0602C Steam Heat Coil- Bottom S4*** 5JA202C Hot Water Heat Coil- Bottom W*** 5WH090H Hot Water Heat Coil- Bottom W22*** 5WS0902C Steam Heat Coil- Top S*** 5JA060H Steam Heat Coil- Top S2*** 5JA20H Steam Heat Coil- Top S3*** 5JA0602C Steam Heat Coil- Top S4*** 5JA202C Hot Water Heat Coil- Top W*** 5WH090H Hot Water Heat Coil- Top W22*** 5WS0902C N/S FS Freezestat ALL ALL ALL Diffuser- 27 Supply Fan Diffuser- 30 Supply Fan Diffuser- 33 Supply Fan N/S Valve, 2 Way Steam Heat w/ Act S**E2E 5JA All S**F2E 5JA All S**G2E 5JA All S**H2E 5JA All VM Actuator- 24V, Valve W****E All All Actuator- 24V, Valve W****E All All Valve, 3 Way HW w/ Actuator.25 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All W**H3E 5WH, 5WS All W**J3E 5WH, 5WS All N/S= Not shown on diagram. Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. 2 Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 82

83 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit= E Heaters, Diffusers, Hi Limit Cutouts HL- 20, 3-50 Diagram & Components 5 2 Air Flow 7 7A 6 Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 2 5 Heater Assy- Top 40 E Heater Assy- Top 40 E Heater Assy- Top 40 E N/A Heater Assy- Top 60 E Heater Assy- Top 60 E Heater Assy- Top 60 E N/A Heater Assy- Top 80 E Heater Assy- Top 80 E Heater Assy- Top 80 E N/A Heater Assy- Top 00 E Heater Assy- Top 00 E Heater Assy- Top 00 E00 00 N/A Heater Assy- Top 20 E Heater Assy- Top 20 E Heater Assy- Top 20 E20 20 N/A Heater Assy- Top 60 E Heater Assy- Top 60 E Heater Assy- Top 60 E60 60 N/A Heater Assy- Top 200 E Heater Assy- Top 200 E Heater Assy- Top 200 E N/A Heater Assy- Top 240 E Heater Assy- Top 240 E Heater Assy- Top 240 E N/A N/A= Not Applicable. Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches. 2 Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches. 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 83

84 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit= E Heaters, Diffusers, Hi Limit Cutouts HL- 20, 3-50 Components, Continued Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 2 6 Blank Assy- Bottom E/ Heater Assy- Bottom 200 E Heater Assy- Bottom 200 E Heater Assy- Bottom 200 E N/A Heater Assy- Bottom 240 E Heater Assy- Bottom 240 E Heater Assy- Bottom 240 E N/A HL-20 Hi Limit- Manual Cutout All All All N/A var var var 7A HL3-50 Hi Limit- Auto Cutout All All All var var var 2 Diffuser All All All N/A= Not Applicable. Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches. 2 Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches. 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 84

85 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box Diagrams & Components FB33 FB37 FB32 FB36 FB3 FB35 FB33 FB32 FB3 FB33 FB32 FB3 M33 M37 M32 M36 M3 M35 FB34 FB38 H S 3 M33 M32 M3 FB34 H S 3 M33 FB43 M32 FB42 M3 FB4 H S 3 T B M34 T B M43 M42 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 208/230V 20KW- 60KW DS3 or PB3 460/ 20KW- 60KW DS3 or PB3 460/ 200KW- 240KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 00A Not Used Not Used Disconnect Switch- 50A Disconnect Switch- 250A Disconnect Switch- 400A Disconnect Switch- 600A Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 2 This Shaft is 4.25 OAL and is designed to be cut to length in the field. 3 This Shaft is 7.2 (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 85

86 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box 20-20KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block 75A Power Block 420A PB3 Power Block 3 used w/00a, 50A DS used w/250a DS used w/400a DS used w/600a DS DS3 Disconnect Switch 2 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V HS3 Switch TB Terminal Block M3 Contactor 40A Contactor 2A M32 Contactor 40A Contactor 2A M33 Contactor 40A Contactor 2A M34 Contactor 40A Contactor 2A M35 Contactor 40A M36 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. 2 See the chart on the previous page. 3 Not Used when PB3 Power Block connection is present. 4 Cover- PB3 used with 600A DS3 is p/n Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 86

87 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box 20-20KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB32 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F32 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 87

88 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block 3 used w/00a/50a DS used w/250a DS used w/400a DS used w/600a DS DS3 Disconnect Switch 2 HS3 Switch TB Terminal Block V 230V M3 Contactor 40A M32 Contactor 40A M33 Contactor 40A M34 Contactor 40A M35 Contactor 40A M36 Contactor 40A M37 Contactor 40A M38 Contactor 40A M4 Contactor 40A M42 Contactor 40A M43 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. 2 See chart 3 pages prior. 3 Not Used when PB3 Power Block connection is present. 4 Cover- PB3 for 600A DS3= p/n Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 88

89 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block FB32 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block FB37 Fuse Block FB38 Fuse Block FB4 Fuse Block FB42 Fuse Block FB43 Fuse Block V 230V F3 Fuse- FB Fuse- FB Fuse- FB F32 Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB F37 Fuse- FB F38 Fuse- FB F4 Fuse- FB Fuse- FB F42 Fuse- FB Fuse- FB F43 Fuse- FB Fuse- FB Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 89

90 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers & Vestibules 200, 250 MBH Furnaces Code 34= 020**, 025** 2 Heat Exchanger 22 Burner 38 Burner Control Box 2 Gas Train 3 Ref. Part 200, 250 Qty. No. Description MBH Heat Exchanger Kit Vestibule Vestibule Capillary Plate N/S Turbulator Assy N/S= Not shown on diagram. Parts detail follows this section. 2 Parts detail follows Burner section. 3 Parts detail follows Burner Control Box section. 4 Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulator Assemblies must be ordered separately. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 90

91 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers & Vestibules 320, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces Code 34= 032**, 040**, 050**, 064**, 065**, 079**, 080**, 00** Heat Exchanger Burner Burner Control Box 2 Gas Train 3 Ref. Part 320, , , , 000 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger Kit Vestibule Vestibule N/S Turbulator N/S= Not shown on diagram. Parts detail follows this section. 2 Parts detail follows Burner section. 3 Parts detail follows Burner Control Box section. 4 Quantity varies depending upon the size of the Heat Exchanger. For 320/400 MBH order 6 pc.; for 500/640 MBH order 9 pc.; for 650/790 MBH order 2 pc.; for 800/000 MBH order 5 pc. Note that Turbulators are NOT furnished with the Heat Exchanger Kit. Turbulators must be ordered separately. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 9

92 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Diagrams Burner Control Box , 250, 320 MBH Burners MBH Burners Pilot Valve/ Pressure Regulator Assy Detail 60 Burner Control Box Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 92

93 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Components Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 02 Burner Housing Scroll Wheel-.5 bore Motor-.25 HP, 5/60/ Gun Assembly 200 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace Pilot Mixer Pilot Assembly Damper Assembly Blast Tube Gasket Right Side Damper MBH Furnace MBH Furnace MBH Furnace Left Side Damper MBH Furnace MBH Furnace Slide Damper 200 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 93

94 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Components, Continued Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 7 Blower Gasket Burner Cover Ignition Assembly 20 Glass Cover Glass Cover Support Orifice 200 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Clip Flange Bearing Air Switch Tube Pilot Burner Tube MBH Furnace MBH Furnace Compression Fitting Pilot Tube Manual Cock Valve MBH only Not Used Press. Reg. Valve MBH only Not Used º Comp. Elbow MBH only Not Used Motor Conduit Box MBH only Torsion Spring Not Used Burner Box Baffle MBH Furnace MBH Furnace Valve- Pressure Regulator Valve- Manual: MBH Valve- Solenoid: MBH N/S Flame Rod N/S Ignition Electrode Assy N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 94

95 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Diagrams MBH MBH Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 95

96 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 02 Burner Housing Scroll MBH Furnace MBH Furnace Wheel-.5 bore MBH Furnace MBH Furnace Motor-.25 HP, 5/60/ MBH Furnace MBH Furnace Gun Assembly 200 MBH Furnace N/A 250 MBH Furnace N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 96

97 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 0 Orifice Assembly 200 MBH Furnace N/A 250 MBH Furnace N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace & 800 MBH Furnace MBH Furnace Gasket- Blast Tube Air Box Assy Plate- Actuator Scale Gasket- Blower Panel- Burner Box Cover Ignition Wire Assy 20 Glass Cover- Burner Support- Glass Cover Grommet- Flat Box- Conduit Motor- Actuator 24V Control Arm Control Rod Crank Arm Extension- Crank Arm Bushing- Control Rod Linkage Plate- Adjustable 200 MBH Furnace N/A 250 MBH Furnace N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 97

98 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 322 Plate- Profile 200, 250 MBH Furnaces N/A 320 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Plate- Slide Damper 200, 250, 320, 400 MBH Furnaces MBH Furnace , 650 MBH Furnaces , 800, 000 MBH Furnaces Box- Air MBH Furnaces MBH Furnaces Gasket- Air Box Grommet Bearing- Sleeve Grommet MBH only Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 98

99 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls (Code 34= ****E*, ****R*, ****S*) MicroTech III Controls (Code 2= *E, *F, *W) R23B IT R23A Gas Control Box FSG Detail GV Detail R20A AS TB FLC Panel Detail S3 FSG 25 Ref. Sch. Part Furnace MBH: Qty. No. Sym. Description 200, GV Pressure Reg. Assy Valve Only Manual Cock Valve Not Used Solenoid Valve Not Used Not Used Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada S3 Toggle Switch- 4PST IT Ignition Transformer AS Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Block Terminal Block End Stop Terminal Block End Plate Jumper Terminal R20A Relay- High Amp DPDT/20V R23A Relay- High Amp DPDT/20V R23B Relay- Low Amp DPDT/20V Note that the sensor is NOT sold separately from the controller. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 99

100 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U* MicroTech III Controls (Code 2= *E, *F, *W) R IT R20B 62 R20A 6 AS 3 LS2 LS 34 TB 32 FLC LS, S FSG FSG Detail Ref. Sch. Part Part Qty. No. Sym. Description Number 24 Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS2 Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper R20A Relay-High Amp DPDT/20V R20B Relay- Low Amp DPDT/20V R2 Relay- Low Amp DPDT/20V Note that the sensor is NOT sold separately from the controller. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 00

101 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Inlet Units without Pressure Regulator Valve Code 34= ****E* Gas Flow MBH MBH Ref. Part Part Qty. No. Description Number 205 Shutoff Valve MBH Gas Valve 200, 250, 320 MBH , 500 MBH MBH Units with Pressure Regulator Valve Code 34= ****R*, ****S* Gas Flow 200, 250, 320 MBH Furnaces , 500, 640, 650, 800 MBH Furnaces MBH Furnaces Ref. Part Pressure Regulator Qty. No. Description 2-3 PSI 5-0 PSI 205 Shutoff Valve MBH Pressure Regulator 200, 250, 320 MBH MBH MBH , 650 MBH , 800 MBH MBH Gas Valve 200, 250, 320 MBH , 500 MBH MBH Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 0

102 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Inlet Canada Units Code 07= CC, CD Units without Pressure Regulator Valve Code 34= ****H* 226 Combination Valve Detail Back Wall of Vestibule 292 Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH , 500 MBH MBH Combination Valve Units with Pressure Regulator Valve Code 34= ****T*, ****U* 232 Back Wall of Vestibule Gas Flow MBH MBH Combination Valve Detail Ref. Part Pressure Regulator Qty. No. Description 2-3 PSI 5-0 PSI 226 Shutoff Valve 200, 250, 320 MBH , 500 MBH MBH Pressure Regulator 200, 250, 320 MBH MBH MBH , 650 MBH , 800 MBH MBH Valve- Combination Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 02

103 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Inlet UL Units Code 07= EU, YU Units without Pressure Regulator Valve Code 34= ****H* 226 Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH , 500 MBH MBH Units with Pressure Regulator Valve Code 34= ****T*, ****U* Ref. Part Pressure Regulator Qty. No. Description 2-3 PSI 5-0 PSI 226 Shutoff Valve 200, 250, 320 MBH , 500 MBH MBH Pressure Regulator 200, 250, 320 MBH MBH MBH , 650 MBH , 800 MBH MBH Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 03

104 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Controls: GV2, GV3 UL Units Code 07= EU, YU 248 Gas Controls: 200, 250, 320 MBH Furnace MBH Furnaces Ref. Part Part Qty. 26 No. Description Number 248 Gas Valve- GV Junction Box Junction Box Cover Gas Pipe 200, 250 MBH GV2 320 MBH MBH Furnaces UL Approved (Code 07= EU, YU) 253 GV2 256 GV Gas Controls: MBH Furnace UL Approved Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2, GV3 400, 500 MBH MBH Pressure Regulator 400, 500 MBH MBH Junction Box Junction Box Cover Gas Pipe 400, 500 MBH MBH , 790 MBH , 000 MBH Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 04

105 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Controls: GV2, VM Canada Units Code 07= CC, CD 248 Gas Controls: 200, 250, 320 MBH Furnace MBH Furnaces Ref. Part Part Qty. 26 No. Description Number 248 Gas Valve- GV Junction Box Junction Box Cover Gas Pipe 200, 250 MBH GV2 320 MBH MBH Furnaces Canada Approved (Code 07= CC, CD) GV2 26 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 248 Gas Valve Body- GV2 400, 500 MBH MBH Actuator- VM Pressure Regulator 400, 500 MBH MBH Gas Pipe 400, 500 MBH , 650 MBH MBH , 000 MBH Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 05

106 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Controls: GV, GV2, GV4, GV5, GV MBH Furnaces GV2 254 Gas Controls: 200, 250, 320 MBH Furnace Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV N/S Junction Box N/S Junction Box Cover N/S= Not shown on diagram MBH Furnaces UL Approved (Code 07= EU, YU) GV4 GV MBH Furnaces UL Approved (Code 07= EU, YU) GV5 GV4 254 GV Gas Controls: MBH Furnace UL Approved Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV, GV MBH Gas Valve- GV,GV4,GV MBH MBH Furnaces Canada Approved (Code 07= CC, CD) 247 GV2 GV5 GV MBH Furnaces Canada Approved (Code 07= CC, CD) GV6 247 GV5 GV2 246 GV4 254 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 246 Gas Valve Body- GV2 400, 500 MBH MBH Actuator- GV Gas Valve- GV4, GV MBH Gas Valve- GV4,GV5,GV MBH Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 06

107 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Outlet MBH MBH Modulating Burners Code 34= ****E*, ****R*, ****S* Actuator & Linkage- See next page Ref. Part Part Qty. No. Description Number 275 Pipe w/ Valve Mount MBH MBH MBH MBH Butterfly Valve MBH , 500 MBH MBH Shutoff Valve MBH , 500 MBH MBH MBH Canada MBH UL Actuator & Linkage- See next page MBH Hi Turn Down Burners Code 34= ****H*, ****T*, ****U* MBH 275 Ref. Part Part Qty. No. Description Number 275 Gas Valve MBH , 500 MBH MBH Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 07

108 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Damper Linkage Modulating Burners w/ VM Actuator Code 34= ****E*, ****R*, ****S* 297 Burner Box 295 Butterfly Valve (see previous page) 297 Burner Box 295 Butterfly Valve (see previous page) VM Actuator Switch Kit Transformer Canada Actuator Detail USA Units/ Canada Units ( MBH) Canada Units ( MBH) Ref. Part Furnace MBH Qty. No. Description Actuator Motor- VM Units w/ MicroTech III Controls USA Units Canada Units Crank Arm Ball Joint Linkage Arm Crank Arm Extension Arm (Canada Units Only) Not Used Air Damper Lever Arm Gas Valve Arm Assembly part number. Motor only is p/n 35780, and Switch Kit only is p/n Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 08

109 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 200MBH and 250 MBH Furnace Code 04= A AND Code 34= 020***, 025*** Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 05 Door Assembly Door Assembly Back- Flue Box Flue Box Mount Sleeve Bearing Door Catch Gasket Gasket Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 09

110 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 320MBH thru 000 MBH Furnace Code 04= A AND Code 34= 032***,040***,050***,064***,065***,079***,080***, 00*** Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly 320, 400 MBH , 640 MBH , 790 MBH , 000 MBH Inspection Door Back- Flue Box 320, 400 MBH , 640 MBH , 790 MBH , 000 MBH Angle- Flue Box 320, 400 MBH , 640 MBH , 790 MBH , 000 MBH Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket Hinge Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 0

111 Section H- BlowThru Heat Blank Access Section Notes AND Access Door Latching Assemblies, Key, & Lock Primary Codes that pertain: 38, 34 Additional Codes that pertain: 06 Code 38 determines the section s characteristics. If Code 38= Y, there is no section. If Code 38= F there is a 48 BlowThru Blank/Empty section. If Code 38= E there is a 24 Blank/Empty section. If Code 38= G, H, there is a Straight Attenuator. If Code 38= K, L there is a Straight Attenuator with Tedlar coating. If Code 38= J there is an Elbow Attenuator. If Code 38= M there is an Elbow Attenuator with Tedlar coating. Code 34 determines the BlowThru Heat Section (Section G). There has to be a Section G in order for there to be a Section H, therefore Code 34 CANNOT= YYYYYY. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heat Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. Door Hardware and Gasketing Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing N/S Door Catch N/S Gasket- Horizontal N/S Gasket- Vertical N/S= Not Shown on diagram. If the unit is split at the fan and heat sections (Code 05= F) use p/n Access Door Latching Assemblies, Key, & Lock (All Sections) 2 Ref. Part Part Qty. No. Description Number 0 Door Latching Assy.- LH, 73" Section 2422 var. 02 Door Latching Assy.- RH, 73" Section var. 0 Door Latching Assy.- LH, 97 Section var. 02 Door Latching Assy.- RH, 97 Section var. N/S Access Door Key var. N/S Access Door Lock var. N/S= Not Shown on diagram. 2 These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Once the door handing is determined, it is then necessary to determine the height of the section. The 73" Latching Assembly is used for unit sections 73 inches high (most sections) and the 97" assembly is used for 97" high sections (eg. Section A2 Energy Recovery [Code 20= *E]) Door Latching Assy. Left Hand Door Latching Assy. Right Hand Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page

112 Section I- BlowThru Cooling Section Notes Primary Codes that pertain: 03, 35, 36 Additional Codes that pertain: 06 Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil, and if Code 03= L there is a large face area Coil. Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 48 section. If the first three digits of Code 35= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T, the first three digits of Code 35 must be DYY. Code 36 determines the Cooling Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. NOTE: See Section D for all parts used in Section I. Although the section location is different within the unit configuration, the components are identical. Section Mounted Controls LT6, S6, REC LT6- BT Cooling Section Light/S6- BT Cooling Section Light Switch/REC6-BT Cooling Section Receptacle. Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 2

113 Section J- Final Filter Section Notes Primary Codes that pertain: 39 Additional Codes that pertain: 04, 34, 33 Code 39 determines all of the section characteristics. If Code 39= A, J, B, K, E, L, F, M, G, N, H there are filters; if Code 39= Q, R, S, T then there is a Blank/Empty section. If Code 39= Y, there is no section. Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts. Code 33 indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description. Door Hardware and Gasketing Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing N/S Door Catch N/S Gasket- Horizontal N/S Gasket- Vertical N/S= Not Shown on diagram. If the unit is split at the fan and heat sections (Code 05= F) use p/n Section Mounted Controls HL23 Gas Hi Limit Control: Code 04= A AND Code 39 DOES NOT= Y PC6 Clogged Filter Control: Code 39 DOES NOT= Y, R, S, T Gas Hi Limit Control Clogged Filter Control 387 Unit Air Flow Control HL23 Gas Heat Hi-Limit (Firestat) Supplied with PC6 Harness from Main/ Split Box Unit Base Ref. Part Part Qty. No. Description Number 386 Stat Support HL23 Firestat Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 3

114 Section J- Final Filter Section Filters Flat Filter Rack- Code 39= A, E, J, G, N 4A 4 5A 5 Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 24 x 24 x 2 High Heat A, E A, J Filter- 95% Eff- Cartridge, 24 x 24 x 2 Standard S, W A, J Filter- 95% Eff- Cartridge w/ Intersept, 24 x 24 x 2 ALL ALL E, L 8 Filter- 95% Eff- HEPA Cartridge, 24 x 24 x 2 ALL ALL G, N 8 4A Gasket- Filter High Heat A, E ALL Gasket- Filter Standard S, W ALL Filter- 95% Eff- Cartridge, 2 x 24 x 2 High Heat A, E A, J Filter- 95% Eff- Cartridge, 2 x 24 x 2 Standard S, W A, J Filter- 95% Eff- Cartridge w/ Intersept, 2 x 24 x 2 ALL ALL E, L 4 Filter- 95% Eff- HEPA Cartridge, 2 x 24 x 2 ALL ALL G, N 4 5A Gasket- Filter High Heat A, E ALL Gasket- Filter Standard S, W ALL Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 4

115 Section J- Final Filter Section Filters, Continued Staggered Filter Rack- Code 39= B, F, K, M 4 4A 5 5A 4 4A Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 24 x 24 x 2 High Heat A, E B, K Filter- 95% Eff- Cartridge, 24 x 24 x 2 Standard S, W B, K Filter- 95% Eff- Cartridge w/ Intersept, 24 x 24 x 2 ALL ALL F, M 8 4A Gasket- Filter High Heat A, E B, K Gasket- Filter Standard S, W B Filter- 95% Eff- Cartridge, 2 x 24 x 2 High Heat A, E B, K Filter- 95% Eff- Cartridge, 2 x 24 x 2 Standard S, W B, K Filter- 95% Eff- Cartridge w/ Intersept, 2 x 24 x 2 ALL ALL F, M 8 5A Gasket- Filter High Heat A, E B, K Gasket- Filter Standard S, W B, K Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 5

116 Section K- Discharge Plenum Section- RPS Notes Primary Codes that pertain: 40 Additional Codes that pertain: 6,, 6, 34, 35, 36, 38, 39, 4. Code 40 determines the discharge direction. RPS units may have bottom discharge (Code BE, BY) OR side discharge (Code LY, RY, SY). VAV damper option is Code *E. Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. Code, Disconnect Switch option, influences Access Door part numbers. Code 6 determines Smoke Detectors. If Code 6= 2, 3 there is a Supply Air Smoke Detector (SD). For RPS units with heat the SD is in Section K. For RDT units, OR RPS draw thru cooling only units (units with no separate discharge plenum section) SD is in the Supply Air section (Section F). Codes 34-39, the BlowThru/Final Filter section codes, and Code 4, the special Blank/Empty section code, pertain to some of the final assembly part numbers. If there is no BlowThru final section then the Discharge Plenum is attached directly to the Supply Air Section and some of the final assembly part numbers are different than they are if the BlowThru section is present. If Code 4= Y (no Blank Access Compartment), then the Discharge Plenum end panels are painted. If the Blank/Empty section is present then the end panels are unpainted. Note: The RPS Main Control Box is located in the Discharge Plenum Section. However, Main Control Box components are listed in Section N. Section Mounted Controls OAT, DAT, SD OAT 7 DAT 8 Discharge Air Temperature Sensor- DAT & Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor- OAT DA Temp. Sensor- DAT Smoke Detector Detail 5 50 Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD Sensing Tube Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 6

117 Section K- Discharge Plenum Section Discharge Damper Assembly- w/ Actuator ACT5 Code 40= BE ACT5 Actuator Linkage Detail Ref. Part Part Number Qty. No. Description C40= BE Complete Damper Assy. w/ Actuator Motor Mount Blade Angle- Linkage Blade- Angle Shaft- Damper Linkage- Shaft Bearing, Flange- Damper Actuator, 24V ACT Crank Arm Ball Joint Bearing- Sleeve Gasket Support- Actuator Retainer- Actuator Bearing- Sleeve NOTE: This Discharge Damper and ACT5 Actuator assembly may also be located in Section F (Supply Air). The Discharge Air opening is in the Supply Air section on RDT units, and RPS DrawThru units with no BlowThru heat (applications where Section F is attached directly to the condensing unit, OR is the end of the unit). Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 7

118 Section L- Out-of-Airstream Blank Access Section Notes Primary Codes that pertain: 4 If Code 4= Y, there is no Blank/Empty section. If Code 4=, there is a 48/24 Blank/Empty section with Access Doors and Light (LT20). When Code 4= 2, there is a 48 Blank/Empty section with Access Doors and Light (LT20). For sheet metal components that make up the Out-of-Airstream Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H. The blank access section may be installed on an RPS unit. Doors, Gasketing and Hardware Ref. Part Section Size No. Description 48 (C4= ) Qty. 48/24 (C4= 2) Qty. N/S Door Assembly N/S Gasket- Horizontal N/S Gasket- Vertical N/S Door Sleeve Bearing N/S Door Catch N/S= Not Shown on diagram. Section Mounted Controls LT20, REC20, S20- Section Mounted Light LT20- Blank Access Section Light/S20- Blank Access Section Light Switch/REC20- Blank Access Section Receptacle Ref. Part Part Qty. No. Description Number 284 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 8

119 Section M- Condenser Section Notes Primary Codes that pertain: 09, 23, 43, 44, 45, 47 This section houses the Compressors, Condenser Coils, Pressure Controls Box, and Fan Deck. The Compressor high and low pressure controls as well as the fan pressure controls are always located in this section as well as SpeedTrol Inverters and Line Reactors (if supplied) in a box mounted where the air handler and condensing unit attach. Code 09, unit voltage, affects Compressor Contactors and Motor Protectors as well as the Compressor selection. Code 43 determines if the Micro Channel Condenser Coils have Seal Tite Conduits and/or Coil Guards; and whether the Coils are Electrofin coated. Code 44 shows the type of compressor selected. For this form Code 44 always = V, W for units with Inverter Compressors. For standard OR Digital Scroll Compressor units (Code 44= R, D) refer to form Note that RPS, RDT074Ds are inverter compressor only units. Code 45 determines the way the compressor is mounted. Code 47 determines Condenser Fan operation. Note that ALL inverter compressor units have SpeedTrol (Low Ambient operation [Code 47= 2, L]) as standard. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 9

120 Section M- Condenser Section Condenser Fan Deck Assembly Diagrams: Code 47= 2 Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail Fan # Fan # Fan # 2 End of Unit Fan # End of Unit Fan # 22 Fan # 2 045D, 050D Fan Deck Detail CDF60 CDF50 Fan # 23 Fan # 22 Fan # 22 05D Fan Deck Detail Fan # 2 CDF5 End of Unit CDF53 End of Unit MOTOR GND WIRE 05 Fan # 2 Fan # 3 Fan # 2 Fan # 063D Fan Deck Detail (063D shown) Fan # Fan # 2 Fan # 3 Fan # 24 Fan # 5 Fan # 4 Fan # 2 Fan # 22 Fan # 23 End of Unit 074D Fan Deck Detail Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 20

121 Section M- Condenser Section Condenser Fan Deck Assembly Components: Code 47= 2 Ref. Part Part Unit Size No. Description Number Condenser Coils Code 43= M* x x " x 84" Condenser Coils Code 43= T* x x x Condenser Coils, Coated Code 43= P* x x x Condenser Coils, Coated Code 43= U* x x x Condenser Fan Code 47= 2 55 Panel- Blank Top Panel Motor- Condenser, Motor- Condenser, Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of two per Motor. 2 Note that the same p/n and quantity is also used for Quiet Fan Assemblies (Code 47= 4). Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 2

122 Section M- Condenser Section Quiet Fan Assembly Code 47= 4 Ref. Part Part Unit Size No. Description Number Quiet Fan Assy., 2 208V V Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor Mount, and Fan Top Panel are NOT available separately. 2 For Top Panel Blank Panels Bub # 55) see the previous page. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 22

123 Section M- Condenser Section Compressors Circuit #: Code 44= V, W 3 045D thru 063D Tandem shown Ref. No. Part Number Compressors Unit Size , 3, N/S N/S N/S 208/230V Crankcase Heater Misc. Components Rotolock Connector Teflon Seal N/S= Not shown on diagram. Note that even though these compressors are factory installed as assemblies, replacement compressors are sold as SINGLE compressors only. 208/230V 208/230V 208/230V 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 23

124 Section M- Condenser Section Compressors Circuit #2: Code 44= V, W 2A 2B Compressor Sightglass & Gasket Optical Oil Sensor location Oil Injection Solenoid location Unit Size /230V Ref. Part No. Number Compressors A Sightglass, Compressor B Gasket, Sightglass N/S Crankcase Heater N/S= Not shown on diagram. Refer to the following page. 208/230V 208/230V 208/230V 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 24

125 Section M- Condenser Section Inverter Compressor Components A Oil Injection Solenoid Optical Oil Sensor 27 Discharge Temp. Sensor Ref. Part Part Qty. No. Description Number 25 Solenoid, Oil Injection, 24V Oil Sensor, Optical A Sight Glass/Prism, Optical Oil Sensor Sensor, Compressor Discharge Temperature Connector, Rectangular Fitting, Male The Sight Glass/Prism comes assembled with Optical Oil Sensor p/n (Ref # 26). If ONLY the Sight Glass/Prism is required use p/n Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 25

126 Section M- Condenser Section Compressor Mounting Components Compressor Mounting Circuit # Unit Size 045, 063, 074 Unit Size 050, Ref. Unit Size Part Part Qty. No. Description Number , 063 Grommet , 05 Mounting Kit Grommet , 063 Sleeve Sleeve , 063 Screw Screw , 063 Washer Washer , 063 Washer, Locking Washer, Locking Compressor Mounting Circuit #2 02 Ref. Unit Size Part Part Qty. No. Description Number 02 ALL Mounting Kit Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 26

127 Section M- Condenser Section Condenser Coil Guards: Code 43= *G, B Ref. Part Part Unit Size No. Description Number Coil Guards (Code 43= *G, B) 0 Side Grille End Grille End Grille End Filler Panel End Filler Panel Side Grille, Pressure Controls Side Grille, Pressure Controls Pressure Control Box Filler Panel Side Grille, VFD Side Grille, VFD Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 27

128 Section M- Condenser Section Pressure Controls Box 045D thru 063D SPTRL PT HP A 235 LP SPTRL A 235 PT2 HP LP Ref. Sch. Part Part Qty. No. Sym. Description Number 220 TB35 Terminal Block Assy TB36 Terminal Block Assy N/S TB37 Terminal Block Assy , 234 LP, 2 Switch- Low Pressure HP, 2 Switch- High Pressure SPTRL Switch- SpeedTrol Pressure A - Harness, Pressure Transducer Valve Core Valve Cap PT, 2 Pressure Transducer , 244 VFD, 2 SpeedTrol Inverter- Size 045, 050, 05D 208/230V, 3HP , 3HP , 3HP , 244 VFD, 2 SpeedTrol Inverter- Size 063D 208/230V, 4 HP , 4 HP , 4 HP LRB, 2B Line Reactor- SpeedTrol () N/S= Not shown on diagram. For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 28

129 Section M- Condenser Section Pressure Controls Box- 073D SPTRL PT HP LP SPTRL PT2 HP LP Ref. Sch. Part Part Qty. No. Sym. Description Number 220 TB35 Terminal Block Assy TB36 Terminal Block Assy N/S TB37 Terminal Block Assy , 234 LP, 2 Switch- Low Pressure HP, 2 Switch- High Pressure SPTRL Switch- SpeedTrol Pressure Valve Core Valve Cap Harness, Pressure Transducer PT, 2 Pressure Transducer VFD Inverter- SpeedTrol, 7.5HP 208/230V VFD2 Inverter- SpeedTrol, 5.0 HP 208/230V LRB, 2B Line Reactor- SpeedTrol () N/S= Not shown on diagram. For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 29

130 Section M- Condenser Section Factory Supplied Powered Receptacle- Code 23= ***F* DS6, TB7, T6, FU6A, B, C Main Control Box Pressure Controls Box (073D shown) Voltage Ref. Sch. Part Part No. Sym. Description Number 0 DS6 Fuse Holder/Circuit Protector 2P, 30A, 600V FU6A, B Fuse 20A/600V Fuse 0A/600V Fuse 8A/600V TB7 Terminal, 2 x 2 Green Terminal Block End Plate Terminal, 2 x 2 Grey Terminal Block End Stop Grey T6 Transformer 2KVA Transformer 2KVA Transformer 2KVA Terminal Cover Kit FU6C Fuse 20A/600V V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 30

131 Section M- Condenser Section Inverter Compressor Control Box Local Control Panel TB4 Detail D, 050D, 05 shown Ref. Sch. Part Part Qty. No. Sym. Description Number 020 TB4 Terminal Block Assy End Stop Terminals Socket, Relay R38, 39 Relay, 20V R40 Relay, 24V End Plate Heater, 20V Tstat, Heater VFD/AFD2 Inverter, Compressor 4 208/230V Local Control Panel, Inverter Muffin Fan Louver Kit Filter Kit Cylinder Lock The Terminal Block Assembly includes End Stops, Terminals, Relays, Relay Sockets, and an End Plate. Refer to the detail drawing to identify individual parts of this assembly. 2 Part ONLY of Terminal Block Assembly p/n Contact Daikin Applied with model and serial number information so that the correct inverter can be identified. 4 Note that the Local Control Panel (Ref # 329) is NOT supplied with the inverter. It must be ordered SEPARATELY if needed. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 3

132 Section N- Main Control Box Notes Primary Codes that pertain: 08, 09,, 2, 3, 4, 5, 6, 7, 8, 23 Additional Codes that pertain: 04, 9, 20, 22, 27, 30, 32, 34, 35, 40 The Main Control Box is comprised of three primary parts The Deadfront Door with the Keypad, the Control Panel, and the Power Panel. Code 08 determines where the Control Box is installed- D indicates the Discharge Plenum (RPS), F indicates the Supply Air Section (RDT). Code 9 is the unit voltage and affects the Transformers, Fan Overloads/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Power/Terminal Block OR a through-the-door Disconnect. Code 2 determines which type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, OR none) and whether the unit uses Discharge Temperature, Space Control, OR Zone control. There is an MCB and separate Expansion Boards (Condenser, Electric Heat, Energy Recovery) in the Control Box. Code 3 determines the presence of Duct and/or Space Sensors. Codes 4 and 5 determine the Supply and Return Fan Inverter characteristics. Code 6 determines the presence of Smoke Detectors. Code 7 AND/OR 23 determine miscellaneous electrical options including whether the unit has a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc. Code 8 indicates whether a unit has a Remote Keypad Display and/or a unit mounted Receptacle. Codes 9, 20 and 22 are return air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc, have an impact on Contactors, Motor Protectors, Fuses, and Duct Sensors. Code 27 determines the draw through section, and can impact the Cooling Circuit Relays. Code 32 determines horsepower for the Supply Fan Motor which, like the Return Air Motor, will affect Contactors, Motor Protectors, Fuses, Overloads, etc. Codes 04, 30, (RDT) 34, and 35 determine the BlowThru section, and the heat type, which will impact the Transformers, heat circuit Relays, and cooling circuit Relays. Code 40 determines if there is a VAV/Discharge Damper and associated Relay. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 32

133 Section N- Main Control Box Control Box Component Label Diagram GOI Number: H R02 MB= Main Box; BB= Bypass Box; EB= Electric Heat Box; GB= Gas Box; PB= Prop Exhaust Box; Location Device ID McQuay Part # Description GB AS Ctrl-press air switch gas burner GB AS Conduit fitting nipple GB FLC Control Temp Fan Limit Gas Heat GB FSG Ctrl-temp flame safegrd base GB FSG Ctrl-temp Flame Safegrd Control GB FSG Ctrl-temp flame safegrd amplifier GB FSG Ctrl-temp flame safegrd timer 90 GB IT Transformer Ignition GB LS Limit switch GB LS Limit switch GB R20A DPDT Relay 5A 20VAC GB R20A Mounting Adapter 2P Relay to Dinra GB S Switch Toggle 4PST 25V MB BNMS Communication Card, BACnet-MSTP, MT MB DHL Pressure Switch SPDT MB DS Circuit Breaker Molded Case Switch MB DS lug kit, 3 pcs with power control t MB DS Connector -4 quick connect tab MB DS lug kit, 3 pcs, T3 Frame, 225A MB DS SCREW, PANHEAD AB-type, #8-8 X 3" MB DS Circuit Breaker Operating Mechanism MB DS HANDLE, PISTOL, ABB DISCONNECT, RED MB DS Fuse holder, Circuit Protector, 2 P MB DS Fuse 0A Rejection Type MB EXP-B Extension I-O 2 5 Points MB EXP-B Connector for extension I-O - Direc MB EXP-C Extension I-O 2 5 Points MB EXP-C Connector for extension I-O - Direc MB F Fuse 7A Rejection Type MB FA Fuse 8A Rejection Type MB FB Fuse 8A Rejection Type MB FC Fuse 5A Midget Non-Rejection Ty MB F Fuse 7A Rejection Type MB F Fuse 5A Midget Non-Rejection Ty MB FB Fuse 80A 600V Class J Fast Actin MB FB Fuse, 30A 600V Class CC Type T Fast MB FB2M Fuse, 70A, 600V, Class J Fast Actin MB M Contactor IEC 32A 20VAC Coil Sprin MB M MMP to Contactor Link Module Screw MB M MMP to Contactor Spacer Size S0 MB M SCREW, PANHEAD B-type, #8 X " MB M Contactor IEC 32A 20VAC Coil Sprin MB M MMP to Contactor Link Module Screw MB M MMP to Contactor Spacer Size S0 MB M SCREW, PANHEAD B-type, #8 X " MB MCB Base Controller with IP and Inbuilt MB MMP MMP Class 0 Size S0 7 to 22A Scre MB MMP MMP Auxiliary Contact Sizes S00 and MB MMP MMP Bus Bar 2 Position No Lateral A MB MMP MMP Bus Bar Type E Feeder Terminal MB MMP MMP Class 0 Size S0 7 to 22A Scre MB MMP MMP Auxiliary Contact Sizes S00 and MB OAER DPDT Relay 0A 24VAC MB OAER Relay Socket DPDT MB PB Distribution Power Terminal Brd 7 MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 24VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 24VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R PDT Relay 0A 20VAC MB R Relay Socket 3PDT MB REC Receptacle Ground Fault Interrupter MB RES RESISTOR 500 Ohm -8 Watt % Pr MB RES RESISTOR 000 Ohm -8 Watt % Pr MB RES RESISTOR 500 Ohm -8 Watt % Pr MB S Switch Toggle DPST 25V MB S Switch Toggle 2position ON-ON S MB SPS SENSOR, AIR PRESSURE/VELOCITY, DIN MB T MICRON Transformer, CPT, W/ FB,50 MB T Cover, Terminals, Micron 6-terminal MB T Cover, Fuseholder, Micron Type 2 Tr MB T Washer, /4" Flat MB T Washer, Split Lock MB T Transformers 75va 20V-24Vac MB T Transformers 75va 20V-24Vac This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 33

134 Section N- Main Control Box Control Panel- MicroTech III Units with Controller Code 2= *E, *F, *W- Diagram R24 R63 TB COM MCB See Power Panel See Power Panel PL - PL43 Plugs The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 34

135 Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- 2 Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad Remote Interface Display Expansion Module EXP A Expansion Module- Condenser/Energy Recovery EXP B Expansion Module- Heat EXP D Expansion Module- Specials, Terminal Block, EXP- 2 Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Hot Gas Reheat RHB, 2 Hot Gas Reheat Interface Boards Code 54= BM, BL Communication Card COM Bacnet- MSTP Code 2= BE, BF, BW Bacnet- IP Code 2= EE, EF, EW LonWorks- Discharge Code 2= LE, LW LonWorks- Constant Volume Code 2= LF Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES2 Resistor- Refrigeration Circuit #2 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS2, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Section N- Main Control Box Control Panel- MicroTech III Units with Controller Code 2= *E, *F, *W- Components Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/20A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A Transformers T2 Transformer- Control 20-24V T3 Transformer- Control 20-24V Duct Hi Limit and Duct Static Pressure Sensors DHL Duct Hi Limit Switch SPS, 2 Pressure Transducer- Duct Sensor Pressure Transducer- Space Sensor Not Shown on diagram. 2 Quantity varies depending upon unit size and options selected. 3 SPS Duct Sensor Code 3=, 2, 3. SPS2 Duct Sensor Code 3= 2. SPS2 Space Sensor Code 3= 3, 4. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 35

136 C F Sch. Part Part Qty. Sym. Description Number Relays R Relay- SpeedTrol inverter VFD R2 Relay- Condenser Fan R3 Relay- Condenser Fan R4 Relay- Condenser Fan R7 Relay- SpeedTrol inverter VFD R20 Relay- Heat R22 Relay- Gas Heat R24 Relay- Gas Heat Alarm R25 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,2,3,5,6, R26 Relay- Iso Damper- Open/Close R28 Relay- Isolation Damper Safety R45 Relay- UV Lights R63 Section N- Main Control Box Control Panel- MicroTech III Units with Controller Code 2= *E, *F, *W- Components, Continued Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4= 2, 5, 7 Vars. Code 3=, 2, 3, 4, Y R8 Relay- Inverter Reset 4P/6A/24V R82 Relay- Inverter Reset 4P/6A/24V R83 Relay- Smoke 4P/6A/24V R84 Relay- Smoke 4P/6A/24V R85 Relay- Smoke 4P/6A/24V R86 Relay- Smoke 4P/6A/24V R87 Relay- Smoke 4P/6A/24V R88 Relay- Smoke 4P/6A/24V Time Delays TD20 Time Delay- Return Air Fan Terminal Block TB Terminal Block Sensors ZNT Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj. 2, DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only (Code 2= *F). 3 Not Shown on diagram. 4 Digital Room Sensor p/n is the preferred option. The other Zone Temperature Sensors are available as options. For positive p/n identification, refer to the drawings below. ZNT Sensor ZNT Sensor 3770 ZNT Sensor 3780 Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 36

137 Section N- Main Control Box Power Panel Diagram See Control Panel See Control Panel F F22 PVM FC FB FC PL - PL43 Plugs PB REC The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 37

138 Section N- Main Control Box Power Panel Components Power Panel- Terminal Blocks, T Transformer & Fusing Sch. Part Part Voltage Sym. Description Number 208V 230V Terminal Blocks TB2,3,4,7 Terminal Block Transformer- Main 2 T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= Units with UV Lights Code 7 (2nd digit)= FC Fuse- T Transformer Fuse- T Transformer Fuse- T Transformer Varies depending on unit options. Part number is for one individual section. Ground block is p/n When required TB2, 3, 4, 7 use Jumper p/n (2 pole), (3 pole), (4 pole), (5 pole). 2 T transformers also use Fuse Puller Kit p/n & Cover Kit p/n Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; = Non- Gas Heat Units with no UV lights. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 38

139 Section N- Main Control Box Power Panel Components, Continued Power Panel- Fusing, Phase Protection, Ground Fault, Power Blocks Sch. Part Part Voltage Sym. Description Number 208V 230V Fuses, continued F2,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F2 Fuse VA transformer F3 Fuse- Blower Motor Code 04= A F5 Fuse- UV Lights Code 7 (2nd digit)= Phase Voltage Monitor Code 7= P,A,C,D,H,J,K PVM, 2 Phase Voltage Monitor (2/6 & Earlier) Phase Voltage Monitor (2/6 & Earlier) Phase Voltage Monitor (/7 & Later) Phase Voltage Monitor (/7 & Later) Socket, PVM (/7 & Later) Ground Fault Protection Code 7= G,B,C,D,K GFR, 2 Ground Fault Relay- SPDT GFS, 2 Ground Fault Sensor Power Blocks PB, PB2 Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 255A Lug- 255A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 620A Cover- 620A Block Lug- 620A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 208/230V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 420A Power Block- 760A Cover- 760A Block PB2 Power Block- Power Distribution Code 04= E 20, 40 KW Electric Heat , 80, 00, 20 KW Electric Heat , 80, 00, 20 KW Electric Heat KW Electric Heat , 240 KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. PB2 is installed when Code = Q. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 39

140 Section N- Main Control Box Power Panel Components, Continued Power Panel- Power Blocks, continued, Receptacle, Plugs Sch. Part Part Voltage Sym. Description Number 208V 230V Power Blocks, continued PB0 Power Block- Supply Fan Code 5= F PB20 Power Block- Return Fan Code 5= F Receptacle REC Receptacle PL- 43 Plugs 2 4 Pin Plug varies varies varies varies 3 6 Pin Plug varies varies varies varies 4 2 Pin Plug varies varies varies varies 5 3 Pin Cap Kit varies varies varies varies 6 6 Pin Cap Kit varies varies varies varies 7 9 Pin Cap Kit varies varies varies varies 8 5 Pin Cap Kit varies varies varies varies All possible Plugs used are listed. Check actual unit to verify which Plug is required. 2 Used for PL, PL, 2, PL3, PL4, PL5, PL6, PL22,PL23, PL24, PL37, PL38. 3 Used with strain relief (p/n ) & 6 pin cap kit (p/n ). Used for PL20, PL2. 4 Used for PL, PL2, PL25, PL26, PL27, PL28, PL29, PL30 (PL & 2 also use Strain Relief p/n & Cap Kit p/n ). 5 Used for PL6, PL7, PL3, PL32, PL33, PL34, PL39, PL40, PL4, PL42. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 40

141 Power Panel- Disconnect Switch DS, 2 Section N- Main Control Box Power Panel Components, Continued Sch. Part Part Voltage Sym. Description Number 208V 230V Disconnect Switch DS, 2 Disconnect Switch- Main, RAF & SAF Switch- 00A Handle Shaft Switch- 50A Handle Mechanism Shaft Lugs Switch- 250A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Switch- 800A Handle Mechanism Shaft Lugs Switch- 000A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed switch to verify the correct Disconnect size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 2 This Shaft is 4.25 OAL and is designed to be cut to length in the field. 3 This Shaft is 7.2 (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 4

142 Section N- Main Control Box Power Panel Supply MMP0 & M0 Fan Contactor Return MMP20 & M20 Fan Contactor Diagrams Phase Barrier Front Mtd. Aux. Contact 2 3E MMP 3 Phase Barrier Front Mtd. Aux. Contact 2 3E MMP 3 MMP 3 2 Link 3B Contactor Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact 3B Link Contactor MMP0 & M0 Link Detail MMP20 & M20 Link Detail 2 HP Motors- All Voltages 3, 5 HP Motors- 460/ 7.5 HP Motors- MMP0 & M0 Link Detail MMP20 & M20 Link Detail 3, 5 HP Motors- 208/230V 7.5 HP Motors- 208/230/ 0 HP Motors- All Voltages 5, 20 HP Motors- MMP0 & M0 Link Detail MMP20 & M20 Link Detail 5 HP Motors- 208/230/ 20, 40 HP Motors- 25, 30 HP Motor- 460/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier 3E Front Mtd. Aux. Contact 2 MMP 3 3 Circuit Breaker (not shown) Link 3B Contactor Terminal Block 4A Contactor 4 Overload MMP0 & M0 Link Detail MMP20 & M20 Link Detail 20, 25, 30 HP Motors- 208/230V 40 HP Motors- 50 HP Motors- 460/ MMP0 & M0 Link Detail 40, 50 HP Motors- 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 42

143 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components 2 Horsepower Motor- Code 22= G*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M20 Contactor- Return Fan 9A Contactor- Return Fan 7A Aux. Contact- NC OR NO MMP20 MMP- Return Fan 5.5-8A MMP- Return Fan A MMP- Return Fan A MMP- Return Fan.8-2.5A B Link E Phase Barrier CB20 Circuit Breaker- Return Fan 5A N/S FB20 Fuseblock- Return Fan Fuse- Return Fan 0A Fuse- Return Fan 9A Fuse- Return Fan 4A Fuse Cover/Puller- Return Fan N/S= Not Shown on Diagram. pc. PER Fuse. 208V 230V 3 HP Motor- Code 22 OR 32= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 5A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 7A Fuse Cover/Puller N/S= Not Shown on Diagram. 2 pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 43

144 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code 22 OR 32= J*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 5A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 25A Fuse- Supply OR Return Fan 20A Fuse- Supply OR Return Fan 0A Fuse Cover/Puller N/S= Not Shown on Diagram. pc. PER Fuse. 208V 230V 7.5 HP Motor- Code 22 OR 32= K*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 5A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 35A Fuse - Supply OR Return Fan 5A Fuse Cover Fuse Cover/Puller N/S= Not Shown on Diagram. 2 pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 44

145 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code 22 OR 32= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link E Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 5A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 50A Fuse- Supply OR Return Fan 45A Fuse- Supply OR Return Fan 20A Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 45

146 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code 22 OR 32= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link E Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 20A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 70A Fuse - Supply OR Return Fan 60A Fuse - Supply OR Return Fan 30A Fuse Cover Fuse Cover Fuse Cover/Puller N/S= Not Shown on Diagram. pc. PER Fuse. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 46

147 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 20 HP Motor- Code 22 OR 32= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Spacer B Link Link Link E Phase Barrier Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 70A Circuit Breaker- Supply OR Return Fan 60A Circuit Breaker- Supply OR Return Fan 30A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 40A Fuse Cover- Supply OR Return Fan N/S= Not Shown on Diagram. 208V 230V 25 HP Motor- Code 22 OR 32= P*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link Link Link E Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 90A Circuit Breaker- Supply OR Return Fan 80A Circuit Breaker- Supply OR Return Fan 40A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 50A Fuse Cover N/S= Not Shown on Diagram. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 47

148 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 30 HP Motor- Code 22 OR 32= Q*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Aux. Contact- NC OR NO MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link Link Link E Phase Barrier CB0, 20 Circuit Breaker- Supply OR Return Fan 25A Circuit Breaker- Supply OR Return Fan 90A Circuit Breaker- Supply OR Return Fan 40A N/S FB0, 20 Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 60A Fuse Cover N/S= Not Shown on Diagram. 208V 230V 40 HP Motor- Code 32= R*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 5A Contactor- Supply Fan 65A Contactor- Supply Fan 50A Aux. Contact- NC OR NO MMP0 Circuit Breaker- Supply Fan 50A MMP- Supply Fan 36-50A MMP- Supply Fan 28-40A B Link Link C Lugs- MMP0 (kit of 3pc.) E Phase Barrier OL0 Overload- Supply Fan A A Terminal Block- Supply Fan CB0 Circuit Breaker- Supply Fan 50A Circuit Breaker- Supply Fan 25A Circuit Breaker- Supply Fan 60A Circuit Breaker- Supply Fan 50A N/S Lugs- CB0 (kit of 3pc.) N/S= Not Shown on Diagram. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 48

149 Section N- Main Control Box Power Panel Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 50 HP Motor- Code 32= S*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 50A Contactor- Supply Fan 65A Aux. Contact- NC OR NO MMP0 Circuit Breaker- Supply Fan 50A MMP- Supply Fan 45-63A MMP- Supply Fan 36-50A B Link E Phase Barrier OL0 Overload- Supply Fan A A Terminal Block- Supply Fan CB0 Circuit Breaker- Supply Fan 80A Circuit Breaker- Supply Fan 60A N/S FB0 Fuseblock- Supply Fan Fuse - Supply Fan 225A Fuse - Supply Fan 75A N/S= Not Shown on Diagram. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 49

150 Control Box Power Panel Compressor Motor Protector MMP, 3, 5 and Contactor M, 3, 5 Unit Size 045D MMP 3 Front Mtd. Aux. Contact 2 MMP 3 2 Front Mtd. Aux. Contact 3B Link Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact A Contactor MMP, 3 & M, 3 Contactor Link Detail 208/230/ MMP, 3 & M, 3 Contactor Link Detail Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3 Contactor- Compressor 40A Contactor- Compressor 32A Contactor- Compressor 25A A Front Mounted Contact- 2NO- 2NC Compressor MMP s & Parts 2 Front Mounted Contact- 2NO- 2NC Front Mounted Contact- 2NO- 2NC MMP, 3 Motor Protector- Compressor 36-45A Motor Protector- Compressor 28-40A Motor Protector- Compressor 7-22A Motor Protector- Compressor - 6A B Link Link N/S Busbar Busbar N/S Busbar Top Feed Busbar Top Feed N/S= Not Shown on Diagram. 208v V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 50

151 Control Box Power Panel Compressor Motor Protector MMP, 3, 5 and Contactor M, 3, 5 Unit Size 050, 05D MMP Front Mtd. Aux. Contact 2 3 Front Mtd. Aux. Contact 2 MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor MMP, 3 & M, 3 Contactor Link Detail 208/230V 3 MMP Link 3B 3A Contactor Spacer MMP, 3 & M, 3 Contactor Link Detail 2 Front Mtd. Aux. Contact 3B Link Contactor A Front Mtd. Aux. Contact MMP, 3 & M, 3 Contactor Link Detail 0 50, 05 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3 Contactor- Compressor 65A Contactor- Compressor 32A Contactor- Compressor 25A A Front Mounted Contact- NO- NC Compressor MMP s & Parts 2 Front Mounted Contact- NO- NC Front Mounted Contact- NO- NC MMP, 3 Motor Protector- Compressor 45-63A Motor Protector- Compressor 7-22A Motor Protector- Compressor 4-20A B Link Link Link N/S Busbar, 2 position Busbar, 2 position N/S Busbar Top Feed Busbar Top Feed N/S= Not Shown on Diagram. 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 5

152 Control Box Power Panel Compressor Motor Protector MMP, 3, 5 and Contactor M, 3, 5 Unit Size 063D Front Mtd. Aux. Contact 2 MMP 3 Front Mtd. Aux. Contact 2 MMP 3 Link 3B A Contactor A 3B Contactor Link MMP, 3 & M, 3 Contactor Link Detail 208/230V MMP, 3 & M, 3 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 25A A Front Mounted Contact- NO- NC Compressor MMP s & Parts 2 Front Mounted Contact- NO- NC MMP, 3 Motor Protector- Compressor 45-63A Motor Protector- Compressor 22-32A Motor Protector- Compressor 8-25A B Link Link N/S Busbar, 2 position N/S Busbar Top Feed N/S= Not Shown on Diagram. 208V 230V 063 Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 52

153 Control Box Power Panel Compressor Motor Protector MMP, 3, 5 and Contactor M, 3, 5 Unit Size 074D Front Mtd. Aux. Contact 2 MMP 3 Front Mtd. Aux. Contact 2 MMP 3 Link 3B A Contactor A 3B Contactor Link MMP, 3, 5 & M, 3, 5 Contactor Link Detail 208/230V MMP, 3, 5 & M, 3, 5 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 25A A Front Mounted Contact- NO- NC Compressor MMP s & Parts 2 Front Mounted Contact- NO- NC MMP, 3, 5 Motor Protector- Compressor 45-63A Motor Protector- Compressor 22-32A Motor Protector- Compressor 8-25A B Link Link N/S Busbar, 3 position Busbar, 3 position N/S Busbar Top Feed Busbar Top Feed N/S= Not Shown on Diagram. 208V V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 53

154 Section N- Main Control Box Power Panel Inverter Compressor Fuseblock & Fuse Components FB2M Unit Size , Ref. No. 208V Part Number Inverter Compressor Fuseblock Fuseblock Cover N/S N/S 230V Inverter Compressor Fuses A A A A A N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 208V 230V 208V 230V 208V 230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 54

155 Section N- Main Control Box Power Panel SpeedTrol Condenser Fan Fusing: Code 47= 2, 4 2 Puller 9B Fuse 9A 9 Fuse Block SpeedTrol Fusing Detail F, F2 & M2, M22 Ref. Sch. Part Part Unit Size No. Sym. Description Number SpeedTrol AFD Fusing 9 FB, 2 Fuse Block A F Fuse Code 47= V 5A V V A A A A F2 Fuse Code 47= V 5A V V A A A B - Fuse Cover/Puller Contact Daikin Applied with model and serial number information so that the correct fuse can be identified. 2 When Code 47= 4 contact Daikin Applied with model and serial number information so that the correct fuse can be identified. Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 55

156 Section N- Main Control Box Power Panel Heat/Energy Recovery Wheel Contactors, MMPs & Fusing Phase Barrier 8E MMP 8 Fuse Block 9 Link 7B 7 Contactor Cover 9B 9A Fuse MMP & Contactor Detail ERW Fusing Detail Unit Voltage Ref. Sch. Part Part No. Sym. Description Number ERW Contactor & Parts 7 M60 Contactor 7A B Link Heat Wheel MMP s & Parts 8 MMP60 Motor Protector 3 8E Phase Barrier ERW Fusing 2 9 FB60 Fuseblock A F60 Fuse B Fuse Cover/Puller N/S CB60 Circuit Breaker 3 3 N/S= Not shown on diagram. Units With No Frost Protection Inverter (Code 24= Y). 2 Units w/ Frost Protection Inverter (Code 24= F). 3 Contact Daikin Applied with model and serial number information so that the correct parts(s) can be identified. 208/230V Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 56

157 Section N- Main Control Box Intelligent Equipment: Code 23= ****A Intelligent Equipment (IE) from Daikin Applied is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation. A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality. Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply. Click on this link to access the RPL for Intelligent Equipment: Rooftop Inv. Cmpr. Units: RPS, RDT Vintage D Rev. H 0/7 RPL / Page 57

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70003700 Revision U 07/2 Roofpak Applied Rooftop Units RPS, RDT, RFS, RCS Sizes 045-079 Tons Vintage D R40a To find your Daikin McQuay Parts distributor, call -800-377-2787 or

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019 Replacement Parts List No. 700052600 Revision G 0/209 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017 Replacement Parts List No. 110502600 Revision I 09/2017 McQuay Superpak Applied Rooftop Units RRS, RSS 018-071 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

RoofPak Applied Rooftop Systems Air Handler

RoofPak Applied Rooftop Systems Air Handler Installation and Maintenance Manual IM 987 RoofPak Applied Rooftop Systems Air Handler Group: Applied Air Systems Part Number: IM 987 Date: May 009 RAH 047C - 077C,,000 to 50,000 cfm RDS 800C - 80C, 4000

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017 Replacement Parts List No. 700014000 Revision B 07/2017 McQuay Two-Stage Centrifugal Chiller WTC 700 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011 Replacement Parts List No. 700019800 Revision A 10/2011 McQuay Two-Stage Centrifugal Chiller WTC 500 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information