Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Size: px
Start display at page:

Download "Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017"

Transcription

1 Replacement Parts List No Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP Vintage H To find your Daikin Applied parts distributor, call or visit

2 Table of Contents Parts List Revision History... 4 Model & Serial Number Nomenclature... 5 Unit Model Number Complete Electrical Legend... 0, Unit Layout Diagrams... 2 Controls 5/3 & Earlier Control Box Diagram... 3 Control Box Component Label Diagram... 4 Common Control Components...5,6 T Control Transformers... 7, 8 T Control Transformer Fuses- FA, FB, FC... 9 Compressor Contactor and Manual Motor Protector Layout Diagrams Compressor Contactor and Manual Motor Protector Components...2, 22 Electric Heat Disconnect Switches Fan Contactor and Manual Motor Protector Configuration Diagrams... 25, 26 Fan Motor Components Controls 6/3 & Later Control Box Diagram Control Box Component Label Diagram Common Control Components... 36, 37 T Control Transformers... 38, 39 T Control Transformer Fuses- FA, FB, FC Compressor Contactor and Manual Motor Protector Layout Diagrams... 4 Compressor Contactor and Manual Motor Protector Components... 42, 43 Electric Heat Disconnect Switches Fan Contactor and Manual Motor Protector Configuration Diagrams Fan Motor Components Refrigeration & Water Components Condenser & Compressor Layout Diagrams Condensers Condenser Components Liquid Line Layout Diagrams Suction Line Layout Diagrams Discharge Line Layout Diagrams Thermal Expansion Valves Miscellaneous Refrigeration Components Water Valves, & Actuator: Code 36= OR Code 37= *, * Compressors Compressor Configurations Independent Refrigeration Circuit: Code 2= S Fan Motors & Inverters Motors Inverters Fan Motor Line Reactors... 7 Fan Section Assembly Diagrams Fan Wheels & Shafts Bearings & Drive Packages Isolator Layout Diagram Rubber-In-Shear (RIS) Vibration Isolators: Code 4= Spring Vibration Isolators: Code 4= Seismic Spring Vibration Isolators: Code 4= Thrust Restraint Isolators Inlet Funnels Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 2

3 Table of Contents, Continued Electric Heater Elements & Hot Water Heating Coils Evaporator Coils Independent Refrigeration Circuit: Code 2= S... 80, 8 Waterside Economizer Coils Cleanable Coils: Code 37= * Return Bend, Cleanout Plug & O-Ring Non-Cleanable Coils: Code 37= 2* Filter Section Air Filter Section and Filter Arrangement Diagrams Air Filters Filter Frame Clips... 9 Ultraviolet Light Components Cabinet Components Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 3

4 Parts List Revision History Revision Date Description New 04/ New. A 07/ Page 20, 2: Added Footnotes 4 & 5. Changed p/n " " to " K" and changed description from "MMP Wire Lock" to "MMP Wire Seal". B 07/ Page 49: Rewrote footnote # regarding ATV2 & ATV22 Lonworks cards per CR/CO #0299 Rev A. C 2/ Page 4: Changed SPS, 2 p/n to & SPS3 p/n to Added footnote #4. D 0/2 Page 46: Added 60HP 208V Prem. Eff. motor p/n Page 70: Added dwg.& p/ns for Ref #9: Handle, Pull Type ; Ref. #0 Screw, ; Ref # Latch, Fastening 35250; & Ref #2 Insert, Latch Rewrote Footnote #. E 08/3 Cover, Rev. pg.: Updated to Daikin McQuay logo format. Various: Changed "McQuay" to "Daikin McQuay". Page 3 (NEW): Added pg. for 8/3 & Later Control Box Components. Repaginated form and updated TOC. Page 4-8 (OLD 5-9 (NEW): Updated "Unit Model Number Complete" nomenclature. Page 9, 0 (OLD) 0, (NEW): Updated Electrical Legend. Page 2 (OLD) 3 (NEW): Rewrote footnote. Page 2-32 (OLD) 3-33 (NEW): Added "6/3 & Earlier" to page headers. Page 4 (OLD) 5 (NEW): Updated footnote #4. Page 9 (OLD) 20 (NEW): Updated dwgs. Page 20, 2 (OLD) 2, 22 (NEW): Updated/corrected cmpr. components as needed. Page 24, 25 (OLD) 25, 26 (NEW): Updated and reorganized dwgs. Page 26-28, 3, 32 (OLD) 27-29, 32, 33 (NEW): Added missing M30B, I, MMP & 230V entries. Deleted footnote #2 when applicable. Corrected contactor p/ns for HP motors per UL508A table. Page (NEW): Added pages for 8/3 & Later components. Repaginated form and updated TOC. Page 34 (OLD) 54 (NEW): Deleted Dual Circuit Condenser table. Page 39 (OLD) 59 (NEW): Deleted Dual Circuit TEV table. Page 40 (OLD) 60 (NEW): Deleted footnotes 4 & 5 and updated p/ns in the table. Page (OLD) (NEW): Added Code 6 information and footnote #. Page 45 (OLD): Deleted Dual Circuit Compressor page. Repaginated form and updated TOC. Page 49 (OLD) 69 (NEW): Updated table header. Page 6 (OLD): Deleted Tandem/Dual Evap. Coil page. Repaginated form and updated TOC. Page (OLD) (NEW): Removed Dual Circuit footnote and updated footnote notation. Page 62 (NEW): Added page with Compressor configuration data. Page 68 (OLD) 88 )(NEW): Added Filter Clip dwgs. Page 70 (NEW): Added page for MD4, 5 VFDs. F 04/5 Cover, Rev pg.: Update to Daikin Applied logo format. Various: Changed "Daikin McQuay" to "Daikin Applied". Page 5, 36: Changed Transducer p/n from " " to "337646". Page 37: Added/updated ZNT dwgs. & p/ns. Page 6: Changed Act. Shaft p/ns "902063" to " " & "37320" to "902795". G /6 Various: Corrected misc. spelling errors. Page 2: Fixed formatting issue. Page 26: Added missing 20HP information to dwgs. Page 35: Updated dwg. Page 37: Changed "Tennant" to "Tenant". Page 59: Restored missing footnote #. Page 6: Rewrote pg. Added dwg. H 08/7 Page 5-9: Misc. updates/additions/corrections. Page 54: Added dwgs. & footnote. Page 55: Updated Ref. # 4 Head Gasket p/n & description. Page 60: Misc. updates. Page 6: Corrected misc. spelling errors. Added dwg. Rewrote pg. header & updated the TOC. Page 69: Rewrote footnote #. Page 73: Corrected Fan Wheel Cabinet Size Code 04 coding. Page 74: Rewrote drive notes. Page 79: Added dwg. Page 80, 8: Added dwg. Re-tabulated the table. Page 82, 83: Updated Econo Coil table. Deleted footnotes. Page 84 (NEW): Added pg. for additional Econo Coil p/ns. Repaginated the form & updated the TOC. Page 84, 85 (OLD) 85, 86 (NEW): Updated Econo Coil table. Deleted footnotes. Page 87 (NEW): Added pg. for additional Econo Coil p/ns. Repaginated the form & updated the TOC. Page 88: (NEW): Added pg. for Filter Section dwgs. Repaginated the form & updated the TOC. Page (OLD) 89-9 (NEW): Rewrote pg. headers & updated the TOC; added footnote #. Page 89 (OLD) 92 (NEW): Rewrote Bulb descriptions. I /7 Various: Deleted SD info. Changed "6/3 & Earlier to "5/3 & Earlier"; "8/3 & Later" to "6/3 & Later", deleted footnotes & updated footnote notation as required. Page 6: Misc. updates. Page, 6: Added RES6 info. Page 23, 44: Updated tables. Rewrote footnotes. Page 36: Updated PSR, 2 p/n & added footnote # 5. Page 37: Added 2/7 & Later PVM p/ns. Page 74: Updated bearing p/ns. Added footnote # & updated footnote notation. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 4

5 Model & Serial Number Nomenclature SWP 023 H Unit Type: SWP = Self-Contained, Water Cooled, Plenum Discharge Vintage Unit Size (Nominal Tons): Independent Circuit (Code 2= S) 02 = 0 Ton 08 = 8 Ton 023 = 23 Ton 028 = 28 Ton 033 = 35 Ton 039 = 40 Ton 044 = 45 Ton 050 = 50 Ton 056 = 55 Ton 062 = 62 Ton 065 = 65 Ton 073 = 70 Ton 080 = 80 Ton 088 = 88 Ton 099 = 95 Ton 05 = 05 Ton 20 = 20 Ton 30 = 30 Ton FBO U Plant Identification FBO = Faribault, MN Sequence Number U = Unit Year of Manufacture = 20 2 = = = 204 etc. Month of Manufacture 0 = January 08 = August 02 = February 09 = September 03 = March 0 = October 04 = April = November 05 = May 2 = December 06 = June 07 = July Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 5

6 Unit Model Number Complete SWP***H S S 27 AL P LE Y Y RP S Y S 3A AEYYYYYY FA 5B HS Code S YY Y Y Y Y FY YY LR S Y YY VY SS 2 2 Y YY A A A Coil Size S= Standard Face Area L= Large Face Area U= Ultra Large Face Area X= Special 04 Cabinet Size S= Small B= Small Tall M= Medium L= Large H= Large Tall X= Special 05 Unit Voltage 2= 208/60/3 27= 460/60/3 29= 230/60/3 37= 575/60/3 06 Starting Option AL= Across the Line Start 07 Field Power Connection D= Single Point, Lockable Disconnect (Unit Mounted) P= Single Point Power Block (Unit Mounted) M= Multi Point, Dual Disconnects A= Multi Point, Dual Power Blocks 08 Control Package Digit : Communication Type L= Lon Mark B= BACNet with MSTP E= BACNet with IP S= Standalone C= BACNet/MSTP card, (VAV Contactor configurable) A= Daikin D3 Gateway card Y= None Digit 2: Control Type E= Discharge Air Control F= Space Comfort Control M= No Temperature Controller (Floating Point) W= Discharge Air with Space Control 09 Special Software Y, A, B= Misc. Factory Codes = 00% Outside Air X= Special 0 Optional MicroTech Hardware Y= No Requirement A= Pressurization Relays B= VFD Bypass Switch C= Pressurization Relays + VFD Bypass Switch X= Special Refrigerants RP= R40A & POE Oil NP= Nitrogen Holding Charge & POE Oil 2 Quantity of Refrigeration Circuits S= Independent Circuit for each Compressor X= Special 3 Refrigeration Specialties Y= No Requirement H= Hot Gas Bypass Circuit # P= Power Factor Capacitors (5 HP Compressors only) 4 Inverter Y= No Requirement = Danfoss With Bypass 3= ABB With Bypass 4, 6= Daikin Applied With Bypass 5= Schneider With Bypass A= ABB Without Bypass G= Danfoss Without Bypass Q= Schneider Without Bypass S, B= Daikin Applied Without Bypass X= Special 5 Cooling Coil Selection 3A= 3 Row 2 FPI, AL Fin, Galv. Case and Pan 4A= 4 Row 2 FPI, AL Fin, Galv. Case and Pan 5A= 5 Row 2 FPI, AL Fin, Galv. Case and Pan 6A= 6 Row 2 FPI, AL Fin, Galv. Case and Pan 3B= 3 Row 2 FPI, AL Fin, Galv. Case, SS Pan 4B= 4 Row 2 FPI, AL Fin, Galv. Case, SS Pan 5B= 5 Row 2 FPI, AL Fin, Galv. Case, SS Pan 6B= 6 Row 2 FPI, AL Fin, Galv. Case, SS Pan 3S= 3 Row 2 FPI, AL Fin, SS Case, SS Pan 4S= 4 Row 2 FPI, AL Fin, SS Case, SS Pan 5S= 5 Row 2 FPI, AL Fin, SS Case, SS Pan 6S= 6 Row 2 FPI, AL Fin, SS Case, SS Pan An "X" located in ANY position in a code string (ESPECIALLY Code 44) indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). In mid 207 the code structure was changed from a 49 code index to a longer format. A sample 49 Code version is shown above. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 6

7 Unit Model Number Complete, Continued 6 Compressor Selections Digit -4: Compressors -4 A= 6HP Compressor B= 7.5/8HP Compressor C= 0HP Compressor D= 3HP Compressor E= 5HP Compressor F= 20HP Compressor G= 25HP Compressor H= 6.7/7HP Compressor J= HP Compressor Y= No Requirement X= Special Digit 5-8: Compressors 5-8 C= 0HP Compressor D= 3HP Compressor E= 5HP Compressor Y= No Requirement X= Special 7 Draw Thru Filter Section Digit : Section Type Y= No Rack F= Front Load Flat Rack P= Front Load Final Rack with Pre-Filter V= Filed Installed Vision with Side Load Access X= Special Digit 2: Filter Type Y= No Filter Media Supplied A= 2" 30% Efficiency (MERV 7) B= 4" 30% Efficiency (MERV 7) C= 4" 65% Efficiency (MERV ) D= 4" 65% Efficiency (MERV ) with 2" Pre- Filter E= 4" 85% Efficiency (MERV 4) with 2" Pre- Filter F= 2" 45% Efficiency (MERV 3) G= 4" 45% Efficiency (MERV 3) H= 4" 45% Efficiency (MERV 3) with 2" Pre- Filter X= Special 9 Fan Motor Selection Digit : Motor Size H= 3HP; J= 5HP; K= 7.5HP; L= 0HP; M= 5HP; N= 20HP; P= 25HP; Q= 30HP; R= 40HP; S= 50HP; T= 60HP: X= Special Digit 2: Motor Type S= ODP Motor, Premium Efficiency T= Totally Enclosed Fan Cooled, Premium Efficiency X= Special 20 Fan Motor Drive Selection ****S= (****)= Fan RPM/ S= Std. Fixed Drive ****F= (****)= Fan RPM/ F= 50% Fixed Drive 2 UV Lights YY= No Requirement UV= UV Lights for Cooling Coil 22 Freezestat Y= None = Factory Mounted on the Water Coil in the airstream 23 Phase Failure Y= None = Factory Mounted 24 Water Flow Sensor Y= None = Factory Provided 25 2nd Duct Static Pressure Sensor Y= None = Factory Mounted 26 Air Flow Switch Y= None = Factory Mounted Air Flow Switch 2= Factory Mounted Fan Relay 8 Fan Selection Digit -2: Fan Size 2= 3.5" Fan 5= 5" Fan 8= 8" Fan 20= 20" Fan 22= 22" Fan 25= 24.5" Fan 27= 27" Fan 30= 30" Fan 33= 33" Fan 37= 36.5" Fan 40= 40" Fan 44= 44" Fan XX= Special Digit 3: Number of Fans = Single Fan 2= Dual Fans Digit 4: Type of Fan B= Air Foil Fan, 9 Blade Single Width Plenum A= Air Foil - Double Width Housed Q= Air Foil Fan, 2 Blade Single Width Plenum Y= FC Fan 27 Supply Fan Discharge Arrangement Digit : Air Discharge Arrangement Y= No Requirement A= Front B= Top Back F= Top Front L= Left R= Right T= Top X= Special Digit 2, Plenum Section Handling Y= No Plenum F= Extended Fan Section M= Extended Plenum (Shipped Separately) P= Extended Plenum (Shipped Installed) X= Special Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 7

8 Unit Model Number Complete, Continued 28 Plenum and Lining YY= No Requirement FP= Foam Insulation with Perforated Sound Baffles FS= Foam Insulation with Solid Liners SP= Fiberglass Insulation with Perforated Liners SS= Fiberglass Insulation with Solid Liners XX= Special 29 Plenum Height YY= No Requirement **= Height in Inches XX= Special 30 Plenum Left Side Discharge Opening Digit -2: Opening Height in Inches YY= No Opening **= Height in Inches XX= Special Digit 3-5: Opening Length in Inches YYY= No Opening ***= Length in Inches XXX= Special Digit 6: Opening Type Y= No Opening R= Rectangular Opening X= Special 3 Plenum Right Side Discharge Opening Digit -2: Opening Height in Inches YY= No Opening **= Height in Inches XX= Special Digit 3-5: Opening Length in Inches YYY= No Opening ***= Length in Inches XXX= Special Digit 6: Opening Type Y= No Opening R= Rectangular Opening X= Special 32 Plenum Front Discharge Opening Digit -2: Opening Height in Inches YY= No Opening **= Height in Inches XX= Special Digit 3-5: Opening Length in Inches YYY= No Opening ***= Length in Inches XXX= Special Digit 6: Opening Type Y= No Opening R= Rectangular Opening X= Special 33 Plenum Back Discharge Opening Digit -2: Opening Height in Inches YY= No Opening **= Height in Inches XX= Special Digit 3-5: Opening Length in Inches YYY= No Opening ***= Length in Inches XXX= Special Digit 6: Opening Type Y= No Opening R= Rectangular Opening X= Special 34 Unit Hand (Connection end when facing back of unit) LL= LH Access LH Piping Connections LR= LH Access, RH Piping Connections RL= RH Access, LH Piping Connections RR= RH Access, RH Piping Connections XX= Special 35 Condensers S= Cleanable Shell & Tube, Low Temperature Condensing, Std. Water Pressure G= Cleanable Shell & Tube, High Temperature Condensing, Std. Water Pressure T= Cleanable Shell & Tube, Low Temperature Condensing, High Water Pressure H= Cleanable Shell & Tube, High Temperature Condensing, High Water Pressure X= Special 36 Condenser Water Regulating Valve Y= No Requirement = 2-Way Modulating Valve (No Flow on Shutdown) 2= Variable Condenser Flow, 2-Way Water Valve not controlled by MTIII (No Flow on Shutdown) X= Special 37 Waterside Economizer Digit Y= No Requirement = Cleanable Coil 2= Non-Cleanable Coil X= Special Digit 2 Y= No Requirement = Std. Valve Control (No Flow on Shutdown) 2= Optional Valve Control (Full Flow on Shutdown) X= Special 38 Airside Economizer Mixing Box YY= No Requirement RY= Remote Damper by Others, MTIII Controlled VY= Field Installed Vision Section XX= Special Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 8

9 Unit Model Number Complete, Continued 39 Heat Selection YYY= No Requirement E6= 6 KW Electric Heat E34= 34 KW Electric Heat E68= 68 KW Electric Heat FMY= MTIII Controlled Field Provided Valve WY= Row 2 FPI HW Coil less Valve SY= Row 8 FPI Steam Coil less Valve WM= Row 2 FPI HW Coil with 2-Way Control Valve SM= Row 8 FPI Steam coil with 2-Way Control Valve XXX= Special 40 Cabinet Lining Digit : Liner Type Y= Standard Construction (No liners, 2".5# Fiberglass Insulation) B= Solid Liners (Foam Insulation, 2" 3# Insulating Sound Baffles in Fan and Plenum Sections) L= Solid Liners (2".5# Fiberglass Insulation) P= Perf-liners (2" 3# Fiberglass Insulation) S= Solid Liners (Foam Insulation) T= Solid SS Liners with Foam Insulation X= Special Digit 2: Access Panel B= Standard Gauge Unpainted Steel Panels S= Standard Gauge Painted Steel Panels M= Unpainted Heavy gauge Steel Panels H= Painted Heavy gauge Steel Panels X= Special 4 Fan Isolation Y= " Deflection Spring = Seismic Restraints with 2" Deflection Spring 2= 2" Deflection Spring 3= RIS (Rubber-in-Shear) 42 Service Valves and Rotolocks Y= Single Filter Drier Service Valve = Single Filter Drier Service Valve with Compressor Isolation Valves 2= Single Filter Drier Service Valve with in line Discharge Valve 43 Modular Construction Y= No Requirement = Modular Construction for Field Assembly X= Special 44 Miscellaneous YY= No Requirement XX= Special 45 Approval Listing Y= No Requirement A= ETL/CETL/ASHRAE 90. P= ETL/CETL X= Special 46 Packaging = Standard (Plastic Wrap) 2= Shrink Wrap X= Special 47 Parts Warranty A= Standard One Year C= Two Years Total D= Three Years Total E= Four Years Total F= Five Years Total Z= Special 48 Compressor Warranty A= Standard One Year Q= Five Years Total X= Special 49 SAF Total Static Pressure ***= Total Static Pressure in inches of water gauge 50 Short Circuit Current Rating (SCCR) YY- None 0= 0 SCCR (Standard) 22= 22 SCCR 65= 65 SCCR X= Special 5 ASHRAE Certification Y- None B= AHRI Certified C= AHRI Certified D= AHRI Certified Labor Warranty Digit : Unit Labor Y- None A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Z= Special Digit 2: Compressor Labor Y- None A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Z= Special 53 Not an SWP Code YY- None XX= Special Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 9

10 Electrical Legend Designation Description Standard Location 2 ACT3 ACTUATOR MOTOR- ECONOMIZER COMPR./COND. SECTION ACT4 ACTUATOR MOTOR- WATER REGULATING/BYPASS VALVE COMPR./COND. SECTION C- 8 POWER FACTOR CAPACITORS- COMPRESSOR CONDENSER SECTION C0 POWER FACTOR CAPACITORS- SUPPLY FAN SUPPLY FAN SECTION CB0 CIRCUIT BREAKER- SUPPLY FAN MAIN CONTROL BOX DAT SENSOR- DISCHARGE AIR TEMPERATURE DISCHARGE SECTION DHL DUCT HIGH LIMIT MAIN CONTROL BOX DS DISCONNECT- TOTAL UNIT OR COND./HEAT MAIN CONTROL BOX DS2 DISCONNECT- SUPPLY FAN/CONTROLS MAIN CONTROL BOX EXP A, B, C MICROTECH III EXPANSION MODULES MAIN CONTROL BOX EWT SENSOR- ENTERING WATER TEMPERATURE COMPR./COND. SECTION FA, FIB FUSE- CONTROL CIRCUIT TRANSFORMER T, PRIMARY MAIN CONTROL BOX FC FUSE- CONTROL CIRCUIT TRANS. T, SECONDARY MAIN CONTROL BOX F5 FUSE- UV LIGHTS MAIN CONTROL BOX FB0 FUSEBLOCKS- SUPPLY FAN INVERTER MAIN CONTROL BOX FB3-34 FUSEBLOCKS- ELECTRIC HEAT MAIN CONTROL BOX FP- 8 FROST PROTECTION- REFRIGERATION CIRCUITS CONDENSER SECTION FS, FS2 CONTROL- FREEZESTAT COIL SECTION GFR, 2 RELAY- GROUND FAULT MAIN CONTROL BOX GFS, 2 SENSOR- GROUND FAULT MAIN CONTROL BOX GRD GROUND MAIN CONTROL BOX HL3-34 HIGH LIMITS, CONTROL- ELECTRIC HEATERS HEAT SECTION, ELECTRIC HP- 8 CONTROL, HIGH PRESSURE- REFRIGERANT ON COMPRESSORS HS3 SWITCH, HEAT- ELECTRIC HEAT DOOR INTERLOCK HEAT SECTION, ELECTRIC HTR- 8 CRANKCASE HEATERS ON COMPRESSORS LP- 8 CONTROL, LOW PRESSURE- REFRIGERANT ON COMPRESSORS LR0 LINE REACTOR- SUPPLY FAN MAIN CONTROL BOX M- M8 CONTACTOR- COMPRESSORS MAIN CONTROL BOX M9 CONTACTOR- SUPPLY FAN, DUAL CONTACTOR START MAIN CONTROL BOX M0 CONTACTOR- SUPPLY FAN MAIN CONTROL BOX M30B CONTACTOR- REVERSING, BYPASS SUPPLY FAN MAIN CONTROL BOX M30I CONTACTOR- REVERSING, INVERTER SUPPLY FAN MAIN CONTROL BOX M3- M34 CONTACTOR- ELECTRIC HEAT MAIN CONTROL BOX MAT SENSOR- MIXED AIR TEMPERATURE FILTER SECTION MCB MICROTECH III CONTROL BOARD MAIN CONTROL BOX MF, 2 MUFFIN FANS MAIN CONTROL BOX MJ MECHANICAL JUMPER MAIN CONTROL BOX MMP- 8 MANUAL MOTOR PROTECTOR- COMPRESSORS MAIN CONTROL BOX MMP9 MOTOR PROT.- SUPPLY FAN, DUAL CONTACTOR START MAIN CONTROL BOX MMP0 MANUAL MOTOR PROTECTOR- SUPPLY FAN MAIN CONTROL BOX MMP30 MANUAL MOTOR PROT.- INVERTER BYPASS, SUPPLY FAN MAIN CONTROL BOX MP- 8 MOTOR PROTECTOR- COMPRESSORS ON COMPRESSORS OAE SENSOR- OUTSIDE AIR ENTHALPY FIELD INSTALLED OAT SENSOR- OUTSIDE AIR TEMPERATURE FIELD INSTALLED PB POWER BLOCK- TOTAL UNIT OR COMPR./ ELEC. HEAT MAIN CONTROL BOX PB2 POWER BLOCK- SUPPLY FAN/CONTROLS MAIN CONTROL BOX PB0 POWER BLOCK- FIELD INSTALLED VFD MAIN CONTROL BOX PC5 CONTROL- PRESSURE, CLOGGED FILTER MAIN CONTROL BOX PC7 CONTROL- PRESSURE RELAY, PROOF OF AIRFLOW MAIN CONTROL BOX PC7 CURRENT SENSING RELAY MAIN CONTROL BOX PSR, 2 TRANSDUCER- HEAD PRESSURE CONTROL CONDENSER SECTION PVM, 2 PHASE VOLTAGE MONITOR MAIN CONTROL BOX R3-8 RELAY- HIGH PRESSURE MAIN/COND. CONTROL BOX R45 RELAY- UV LIGHTS MAIN CONTROL BOX R63 RELAY- DUCT HIGH LIMIT MAIN CONTROL BOX RAT SENSOR- RETURN AIR TEMPERATURE FIELD INSTALLED REC0 RECEPTACLE CABINET SECTIONS RES, 2 RESISTOR- LOW PRESSURE SWITCH MAIN CONTROL BOX RES3 RESISTOR- FREEZESTAT MAIN CONTROL BOX RES4 RESISTOR- ENTHALPY MAIN CONTROL BOX Schematic designators may vary depending on unit size, voltage, and options selected. Refer to the unit schematic for more information. 2 Component locations listed are typical and should be used for reference only. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 0

11 Electrical Legend, Continued Designation Description Standard Location 2 RES6 RESISTOR- STATIC PRESSURE SENSOR MAIN CONTROL BOX S SWITCH- INVERTER/OFF/BYPASS MAIN CONTROL BOX S4 SWITCH- CONTROLS/ON/AUTO MAIN CONTROL BOX S7 SWITCH- INVERTER/OFF/BYPASS MAIN CONTROL BOX S0 SWITCH- CABINET SECTIONS CABINET SECTIONS S2 SWITCH- FAN DOOR INTERLOCK FAN SECTION S40-45 SWITCH- UV LIGHTS DOOR INTERLOCK CABINET SECTIONS SHS SENSOR- SPACE HUMIDITY FIELD INSTALLED SPS, 2 SENSOR- STATIC PRESSURE DUCT/BUILDING MAIN CONTROL BOX SV, SV2 SOLENOID VALVES- LIQUID CONDENSER SECTION SV5, SV6 SOLENOID VALVES- HOT GAS BYPASS COIL SECTION T TRANS.- MAIN CONTROL/UV LIGHTS (LINE/5VAC) MAIN CONTROL BOX T2 TRANSFORMER- CONTROL INPUT (5/24VAC) MAIN CONTROL BOX T3 TRANSFORMER- CONTROL OUTPUT (5/24VAC) MAIN CONTROL BOX T4 TRANSFORMER, EXH. DAMPER ACTUATOR (5/2VDC) MAIN CONTROL BOX TB TERMINAL BLOCK- INTERNAL MAIN CONTROL BOX TB2 TERMINAL BLOCK- FIELD, CLASS 2 MAIN CONTROL BOX TB3 TERMINAL BLOCK- FACTORY MAIN CONTROL BOX TB4 TERMINAL BLOCK- FIELD (5VAC) MAIN CONTROL BOX UV ULTRA-VIOLET LIGHT(S) COIL/DISCHARGE SECTION VFD0 VARIABLE FREQUENCY DRIVE (VFD)- SUPPLY FAN MAIN CONTROL BOX VM VALVE MOTOR- #- HEATING FIELD PROVIDED/INSTALLED VM5 VALVE MOTOR- #5- COOLING COIL SECTION, COOL WFS SENSOR- WATER FLOW CONDENSER SECTION ZNT SENSOR- ZONE TEMP, SETBACK FIELD INSTALLED Schematic designators may vary depending on unit size, voltage, and options selected. Refer to the unit schematic for more information. 2 Component locations listed are typical and should be used for reference only. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page

12 Unit Layout Diagrams Top View Coil Access Control Panel Access Control Panel Evaporator Coil Power Entry Motor/Fan Access Waterside Economizer Coil Supply Fan Motor Front Load Filter Rack Supply Fan Condensate Drain Side View Water Supply Water Return Top Supply Air Opening Return Air Opening Supply Fan Condensate Drain Compressor/Condenser Compressor/Condenser Access Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 2

13 Controls Control Box Diagram 5/3 & Earlier Diagram is representative of a typical Control Box layout. Components, component layout, and component quantity may vary depending upon unit size, voltage, and options selected. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 3

14 Controls Control Box Component Label Diagram 5/3 & Earlier Note that all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options and features. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 4

15 Controls Common Control Components 5/3 & Earlier Sch. Sym. Description Part Number MCB Main Control Board Battery- MCB EXP A, B, C Expansion Module Connector Set for Extension 2 Spring Cage Top Entry Connector, Extension I/O Direct Connect Connector, 2-Pin Spring Cage, Top Entry Connector, 3-Pin Spring Cage, Top Entry Connector, 4-Pin Spring Cage, Top Entry Connector, 5-Pin Spring Cage, Top Entry Connector, 6-Pin Spring Cage, Top Entry Connector, 7-Pin Spring Cage, Top Entry Connector, 8-Pin Spring Cage, Top Entry AWM Advanced Web Module FS, 2 Freezestat Filter Pressure Gauge 0-3 IWC HP- 8 Switch- High Pressure, Refrigerant 3470 LP- 8 Switch- Low Pressure, Refrigerant 3480 HTR- 8 Crankcase Heater- Compressors (6HP, 7HP) Crankcase Heater- Compressors (0HP- 5HP) HL3-34 High Limit- Electric Heat 3 MP- 8 Compressor Motor Protector (3HP & 5HP compressors only) SPS, 2 Duct Static Pressure Sensor Kit SPS3 Building Static Pressure Sensor Kit PSR Refrigerant Pressure Transducer Circuit # PSR2 Refrigerant Pressure Transducer Circuit # PC5 Dirty Filter Switch- Prefilter PC6 Dirty Filter Switch- Final Filter PC7 Airflow Proving Switch (Code 25= ) PC7 Current Sensing Relay (Code 26= 2) DHL Duct High Limit DAT Discharge Air Temperature Sensor EFT Entering Fan Air Temperature Sensor RAT Return Air Sensor OAT Outside Air Temperature Sensor MAT Mixed Air Temperature Sensor EWT Entering Water Temperature Sensor OAE Enthalpy Control, Electro-Mechanical OAE Enthalpy Control, Comparative RAE Return Air Enthalpy Sensor SHS Space Humidity Sensor- Wall Mount SHS Space Humidity Sensor- Duct Mount This Control Board must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so that unit specific software code can be loaded before shipment. 2 These parts are not provided with the Expansion Module. Order separately if needed. 3 Not available separately from the Electric Heater Element. 4 The original Transducer is no longer available. This replacement kit requires minor field modifications for proper installation & operation. The SPS or 2 sensor ONLY is p/n: The SPS3 sensor ONLY is p/n: Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 5

16 Controls Common Control Components, 5/3 & Earlier Continued Sch. Sym. Description Part Number MF Muffin Fan Fan Guard- Muffin Fan R3-8 Relay, High Pressure Relay Base R63 Relay, Duct High Limit Relay Base PVM, 2 Phase Voltage Monitor 208V PVM, 2 Phase Voltage Monitor RES, 4 Resistor,.5K RES2, 3 Resistor,.0K RES6 Resistor, 0.5K (Code 4= 4, S) S Switch- Unit On/Off S4 Switch- Inverter Bypass S7 Switch- Local On/Off to MCB S2 Switch- Fan Door Interlock S40-45 Switch- UV Door Interlock T2 Transformer 5/24 VAC 75VA T3 Transformer 5/24 VAC 50VA WFS Switch, Water Flow (Code 24= ) ZNT Zone Temp. Sensor w/tenant Override 3770 ZNT Zone Temp. Sensor w/tenant Override & Remote Set Pt. Adj COM BACNet MS/TP Communication Module (RSCOM485) COM BACNet /IP Communication Module (IP Cable 0 BaseT) COM LONMARK Space Comfort Controller (SCC) Communication Module COM LONMARK Discharge Air Controller (DAC) Communication Module Remote Keypad Interface Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 6

17 Controls T Control Transformers 5/3 & Earlier Sch. Unit Cabinet No Heat/ Electric UV Part Sym. Size Size Description Lights 2 Heat 3 Lights 4 Number USED WITH 208V UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 500VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X USED WITH 230V UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 500VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X Code 04= *. 2 Code 39 CANNOT= E** AND Code 2= YY. 3 Code 39= E** AND Code 2= YY. 4 Code 2= UV AND Code 39 CANNOT= E**. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 7

18 Controls T Control Transformers, 5/3 & Earlier Continued Sch. Unit Cabinet No Heat/ Electric UV Part Sym. Size Size Description Lights 2 Heat 3 Lights 4 Number USED WITH UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 50VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X USED WITH UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 500VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X Code 04= *. 2 Code 39 CANNOT= E** AND Code 2= YY. 3 Code 39= E** AND Code 2= YY. 4 Code 2= UV AND Code 39 CANNOT= E**. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 8

19 Controls T Control Transformer Fuses- FA, FB, FC 5/3 & Earlier Sch. Unit Voltage Part Sym. Size Description 208V 230V Number USED WITH 500VA T TRANSFORMERS FA, B ALL Fuse- Midget, 6A X X FA, B ALL Fuse, Midget, 4A X FA, B ALL Fuse- Midget, 3A X FC ALL Fuse- Midget, 7A X X X X USED WITH 750VA T TRANSFORMERS FA, B ALL Fuse- Midget, 0A X FA, B ALL Fuse, Midget, 9A X FA, B ALL Fuse- Midget, 5A X FA, B ALL Fuse- Midget, 4A X FC ALL Fuse- Midget, 0A X X X X USED WITH 000VA T TRANSFORMERS FA, B ALL Fuse- Midget, 5A X FA, B ALL Fuse, Midget, 2A X FA, B ALL Fuse- Midget, 6A X FA, B ALL Fuse- Midget, 6A X FC ALL Fuse- Midget, 2A X X X X USED WITH 500VA T TRANSFORMERS FA, B ALL Fuse- Midget, 20A X FA, B ALL Fuse, Midget, 7.5A X FA, B ALL Fuse- Midget, 9A X FA, B ALL Fuse- Midget, 7A X FC ALL Fuse- Midget, 5A X X X X USED WITH 2000VA T TRANSFORMERS FA, B ALL Fuse- Midget, 30A X X FA, B ALL Fuse, Midget, 2A X FA, B ALL Fuse- Midget, 3A X FC ALL Fuse- Midget, 7A X X X X Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 9

20 Controls Compressor Contactor and Manual Motor Protector Layout Diagrams 5/3 & Earlier 2 3B 2 3F 3F C MMP- 8 & M- 8 Link Detail 6HP Cmprs.- ALL 0, 3 HP Cmprs.- 460/ 3E MMP- 8 & M- 8 Link Detail 0, 3 HP Cmprs.- 5 HP Cmprs.- 2 3F 3E MMP- 8 & M- 8 Link Detail 5 HP Cmprs.- 208V 2 2 3F 3F MMP- 8 & M- 8 Link Detail 5 HP Cmprs.- 230V MMP- 8 & M- 8 Link Detail 5 HP Cmprs.- Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 20

21 Controls Compressor Contactor and Manual Motor Protector Components 5/3 & Earlier Compressor Ref. Sch. Part Part 6HP 0HP 3HP 5HP No. Sym. Description Number Code 6 Code 6 Code 6 Code 6 = A = C = D = E USED WITH 208V COMPRESSORS M- 8 Contactor, 32A Contactor, 50A Contactor, 65A Contactor, 80A C Contactor Spacer MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link E Lug Kit (3 Lugs per kit) F Auxiliary Contact /NC/NO N/S MMP Wire Seal K USED WITH 230V COMPRESSORS M- 8 Contactor, 32A Contactor, 40A Contactor, 65A C Contactor Spacer MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link F Auxiliary Contact /NC/NO N/S MMP Wire Seal K N/S= Not shown on diagram. Quantities shown are PER compressor. 2 When ordering an MMP- 8, MMP Wire Seal p/n K must also be ordered. 3 P/N K includes the Wire Seal and installation Instructions. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 2

22 Controls Compressor Contactor and Manual Motor Protector Components, 5/3 & Earlier Continued Compressor Ref. Sch. Part Part 6HP 0HP 3HP 5HP No. Sym. Description Number Code 6 Code 6 Code 6 Code 6 = A = C = D = E USED WITH COMPRESSORS M- 8 Contactor, 8A Contactor, 25A Contactor, 32A C Contactor Spacer MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link F Auxiliary Contact /NC/NO N/S MMP Wire Seal K USED WITH COMPRESSORS M- 8 Contactor, 8A Contactor, 25A Contactor, 32A Contactor, 40A C Contactor Spacer MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link F Auxiliary Contact /NC/NO N/S MMP Wire Seal K N/S= Not shown on diagram. Quantities shown are PER compressor. 2 When ordering an MMP- 8, MMP Wire Seal p/n K must also be ordered. 3 P/N K includes the Wire Seal and installation Instructions. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 22

23 Controls Electric Heat 5/3 & Earlier 34KW Heater Element Components: (Code 39= E34) SCHEMATIC SYMBOL DESCRIPTION PART NO. QTY. 208V: FB3, FB32 FUSE BLOCK, 60A ON FB3, FB32 FUSE, 50A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 32A : FB3, FB32 FUSE BLOCK, 30A ON FB3, FB32 FUSE, 30A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 25A : FB3, FB32 FUSE BLOCK, 30A ON FB3, FB32 FUSE, 25A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 25A KW Heater Element Components: (Code 39= E68) SCHEMATIC SYMBOL DESCRIPTION PART NO. QTY. : FB3, FB32 FUSE BLOCK, 60A ON FB3, FB32 FUSE, 50A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 32A For voltages not listed, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 23

24 Controls Disconnect Switches 5/3 & Earlier Sch. Part Disconnect Switch Component Sym. Description Amps Switch Handle 2 Shaft DS, 2 Disconnect Switch 00 Amp Disconnect Switch 50 Amp Disconnect Switch 250 Amp Disconnect Switch 400 Amp Disconnect Switch 600 Amp This list includes the most common Disconnects offered. Due to the various unit options available, before ordering it is necessary to confirm what amperage Disconnect is installed in the unit, or if this is not known, contact Daikin Applied with model and serial number information to ensure that the correct part(s) are ordered. 2 Includes Mechanism (except 600A Switch see footnote 3). 3 Handle only p/n ; Mechanism only p/n ; Shaft p/n Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 24

25 Controls Fan Contactor and Motor Protector Configuration Diagrams 5/3 & Earlier Fan Contactor Assembly Without Bypass 2 2 3B C MMP0 & M0 Link Detail 3, 5, 7.5, 0 HP Motors- ALL 5, 20 HP Motors- 460/ 25, 30 HP Motors- MMP0 & M0 Link Detail 5, 20 HP Motors- 25, 30 HP Motors- 40, 50 HP Motors- 460/ 2 3E 2 3E MMP30 & M30B, I Link Detail 25, 30, 40, 50 HP Motors- 60 HP Motors- 208/230/ MMP0 & M0 Link Detail 60 HP Motors- Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 25

26 Controls Fan Contactor and Motor Protector Configuration Diagrams, 5/3 & Earlier Continued Fan Contactor Assembly With Bypass B 4A 5 MMP30 & M30B, I Link Detail 3, 5, 7.5, 0 HP Motors- ALL 5, 20 HP Motors- 460/ 25, 30 HP Motors- MMP30 & M30B, I Link Detail 5, 20 HP Motors- 25 HP Motors- 230/ 30, 50 HP Motors- 40 HP Motors- 460/ 60 HP Motors- 3E 4 5 3E MMP30 & M30B, I Link Detail 25 HP Motors- 208V 30, 40 HP Motors- 60 HP Motors- Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 26

27 Controls Fan Motor Components 5/3 & Earlier 3 HP Motor- Code 9= H* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 2A Contactor, 9A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link M30B, I Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker V 230V 5 HP Motor- Code 9= J* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 8A Contactor, 9A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link M30B, I Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker V 230V One pc. is used for M0 Contactors and two pcs. are used for M30B, I Contactors. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 27

28 Controls Fan Motor Components, 5/3 & Earlier Continued 7.5 HP Motor- Code 9= K* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 25A Contactor, 2A Contactor, 9A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link M30B, I Bypass Contactor Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker V 230V 0 HP Motor- Code 9= L* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 32A Contactor, 8A Contactor, 2A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector B Link M30B, I Bypass Contactor Bypass Contactor Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker V 230V One pc. is used for M0 Contactors and two pcs. are used for M30B, I Contactors. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 28

29 Controls Fan Motor Components, 5/3 & Earlier Continued 5 HP Motor- Code 9= M* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 40A Contactor, 25A Contactor, 8A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link M30B, I Bypass Contactor Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker HP Motor- Code 9= N* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 65A Contactor, 32A Contactor, 25A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link M30B, I Bypass Contactor Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker V 208V 230V 230V One pc. is used for M0 Contactors and two pcs. are used for M30B, I Contactors. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 29

30 Controls Fan Motor Components, 5/3 & Earlier Continued 25 HP Motor- Code 9= P* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 80A Contactor, 40A Contactor, 32A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link E Lugs (3 per kit) M30B, I Bypass Contactor Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker V 230V One pc. is used for M0 Contactors and two pcs. are used for M30B, I Contactors. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 30

31 Controls Fan Motor Components, 5/3 & Earlier Continued 30 HP Motor- Code 9= Q* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 5A Contactor, 80A Contactor, 40A Contactor, 32A C Contactor Spacer MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link E Lugs (3 per kit) M30B, I Bypass Contactor Bypass Contactor Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker V 230V One pc. is used for M0 Contactors and two pcs. are used for M30B, I Contactors. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 3

32 Controls Fan Motor Components, 5/3 & Earlier Continued 40 HP Motor- Code 9= R* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 50A Contactor, 5A Contactor, 65A Contactor, 50A MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector E Lugs (3 per kit) M30B, I Bypass Contactor Bypass Contactor Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker Circuit Breaker V 230V 50 HP Motor- Code 9= S* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor Contactor, 65A MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector E Lugs (3 per kit) M30B, I Bypass Contactor MMP30 Manual Motor Protector CB0 Circuit Breaker Circuit Breaker V 230V Also requires 3 field supplied ring terminals. 2 Contact Daikin Applied with model and serial number information so that the needed part(s) can be identified. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 32

33 Controls Fan Motor Components, 5/3 & Earlier Continued 60 HP Motor- Code 9= T* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor, 56A Contactor, 80A MMP0 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector E Lugs (3 per kit) Lugs (3 per kit) M30B, I Bypass Contactor MMP30 Manual Motor Protector Manual Motor Protector CB0 Circuit Breaker Circuit Breaker V 230V Also requires 3 field supplied ring terminals. 2 Contact Daikin Applied with model and serial number information so that the needed part(s) can be identified. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 33

34 Controls Control Box Diagram 6/3 & Later Diagram is representative of a typical Control Box. Components, component layout, and component quantity may vary depending upon unit size, voltage, and options selected. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 34

35 Controls Control Box Component Label Diagram 6/3 & Later GOI Number: H R02 MB= Main Box; BB= Bypass Box; EB= Electric Heat Box; GB= Gas Box; PB= Prop Exhaust Box; Location Device ID McQuay Part # Description MB BNIP Communication Card, BACnet-IP, MT30 MB C63S CAPACITOR, 50V, 00uF, ALUMINUM ELE MB DHL PRESSURE SWITCH, SPDT, 0.05" - 5" W MB DS Circuit Breaker Molded Case Switch MB DS SCREW, PANHEAD AB-TYPE, #8-8 X 3" MB DS Circuit Breaker Operating Mechanism MB DS HANDLE, PISTOL, ABB DISCONNECT, RED MB DSLINELUG LUG KIT, 3 PCS, T3 FRAME, 225A MB DSLOADLUG LUG KIT, 3 PCS, T3 FRAME, 225A MB EXP-A Extension I-O 2 5 Points MB EXP-A Connector for extension I-O - Direc MB EXP-C Extension I-O 2 5 Points MB EXP-C Harness, Remote Connection, Seimens MB FA Fuse 4A Rejection Type MB FB Fuse 4A Rejection Type MB FC Fuse 0A Midget Non-Rejection Ty MB FB Fuse 00A 600V Class J Fast Acti MB M Contactor IEC 40A 20VAC Coil Screw MB M Contactor Auxiliary Contact 2NO 2NC MB M MMP to Contactor Link Module Size S MB M Contactor IEC 40A 20VAC Coil Screw MB M Contactor Auxiliary Contact 2NO 2NC MB M MMP to Contactor Link Module Size S MB M Contactor IEC 32A 20VAC Coil Sprin MB M MMP to Contactor Link Module Screw MB M MMP to Contactor Spacer Size S0 MB M SCREW, PANHEAD B-TYPE, #8 X " MB M30I MMP to Contactor Link Module Size S MB M30I Contactor IEC Reversing 50A 20VAC MB M Contactor IEC 32A 20VAC Coil Sprin MB M MMP to Contactor Link Module Screw MB M MMP to Contactor Spacer Size S0 MB M SCREW, PANHEAD B-TYPE, #8 X " MB MCB Base Controller with IP and Inbuilt MB MMP MMP Class 0 Size S2 8 to 25A MB MMP MMP Auxiliary Contact Sizes S2 and MB MMP WIRE SEAL, TWIST LOCK MB MMP MMP or Overload Dial Cover Sealable MB MMP MMP Class 0 Size S2 8 to 25A MB MMP MMP Auxiliary Contact Sizes S2 and MB MMP WIRE SEAL, TWIST LOCK MB MMP MMP or Overload Dial Cover Sealable MB MMP MMP Class 0 Size S0 7 to 22A Scre MB MMP MMP Auxiliary Contact Sizes S00 and MB MMP MMP Type E Phase Barrier Sizes S00 MB MMP WIRE SEAL, TWIST LOCK MB MMP MMP or Overload Dial Cover Sealable MB MMP MMP Class 0 Size S2 40 to 50A MB MMP MMP Class 0 Size S0 7 to 22A Scre MB MMP MMP Auxiliary Contact Sizes S00 and MB MMP MMP Type E Phase Barrier Sizes S00 MB MMP WIRE SEAL, TWIST LOCK MB MMP MMP or Overload Dial Cover Sealable MB OL30A Overload Relay Class 0 Size S0 20 MB OL30A Overload Relay Remote Mounting Kit MB OL30B Overload Relay Class 0 Size S0 20 MB OL30B Overload Relay Remote Mounting Kit MB PB Distribution Power Terminal Brd 7 MB PC PRESSURE SWITCH, SPDT, 0.05" - 5" W MB PC PRESSURE SWITCH, SPDT, 0.05" - 5" W MB PVM PH Monitor VAC MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 20VAC MB R Relay Socket DPDT MB RES RESISTOR 500 Ohm -8 Watt % Pr MB RES RESISTOR 000 Ohm -8 Watt % Pr MB RES RESISTOR 000 Ohm -8 Watt % Pr MB S Switch Toggle SPST-20A 25va MB S Switch Toggle 3position ON-OFF-O MB S Switch Toggle 2position ON-ON S MB SPS SENSOR, AIR PRESSURE/VELOCITY, DIN MB T MICRON Transformer, CPT, W/ FB, 750 MB T COVER KIT, TERMINAL, MICRON 6- TERM MB T COVER KIT, FUSEHOLDER, MICRON TYPE MB T Transformers 75va 20V-24Vac MB T Transformers 75va 20V-24Vac MB VFD VFD,, 30HP, ACS320, ABB, Frame MB ZZ Commodities Special Note that all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options and features. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 35

36 Controls Common Control Components 6/3 & Later Sch. Sym. Description Part Number MCB Main Control Board Battery- MCB EXP A, B, C Expansion Module Connector Set for Extension 2 Spring Cage Top Entry Connector, Extension I/O Direct Connect Connector, 2-Pin Spring Cage, Top Entry Connector, 3-Pin Spring Cage, Top Entry Connector, 4-Pin Spring Cage, Top Entry Connector, 5-Pin Spring Cage, Top Entry Connector, 6-Pin Spring Cage, Top Entry Connector, 7-Pin Spring Cage, Top Entry Connector, 8-Pin Spring Cage, Top Entry AWM Advanced Web Module FS, 2 Freezestat Filter Pressure Gauge 0-3 IWC HP- 8 Switch- High Pressure, Refrigerant 3470 LP- 8 Switch- Low Pressure, Refrigerant 3480 HTR- 8 Crankcase Heater- Compressors (6HP, 7HP) Crankcase Heater- Compressors (0HP- 5HP) HL3-34 High Limit- Electric Heat 3 MP- 8 Compressor Motor Protector (3HP, 5HP compressors only) SPS, 2 Duct Static Pressure Sensor SPS3 Building Static Pressure Sensor PSR, 2 Refrigerant Pressure Transducers PC5 Dirty Filter Switch- Prefilter PC6 Dirty Filter Switch- Final Filter PC7 Airflow Proving Switch (Code 25= ) PC7 Current Sensing Relay (Code 26= 2) DHL Duct High Limit DAT Discharge Air Temperature Sensor EFT Entering Fan Air Temperature Sensor RAT Return Air Sensor OAT Outside Air Temperature Sensor MAT Mixed Air Temperature Sensor EWT Entering Water Temperature Sensor OAE Enthalpy Control, Electro-Mechanical OAE Enthalpy Control, Comparative RAE Return Air Enthalpy Sensor SHS Space Humidity Sensor- Wall Mount This Control Board must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so that unit specific software code can be loaded before shipment. 2 These parts are not provided with the Expansion Module. Order separately if needed. 3 Not available separately from the Electric Heater Element. 4 This p/n replaces previous versions of this sensor. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 36

37 C F Controls Common Control Components, 6/3 & Later, Continued Sch. Sym. Description Part Number MF Muffin Fan Fan Guard- Muffin Fan R3-8 Relay, High Pressure Relay Base R63 Relay, Duct High Limit Relay Base PVM, 2 Phase Voltage Monitor 208V - (2/6 & Earlier) Phase Voltage Monitor (2/6 & Earlier) Phase Voltage Monitor 208V - (2/7 & Later) Phase Voltage Monitor (2/7 & Later) Socket, Phase Voltage Monitor (2/7 & Later) RES, 4 Resistor,.5K RES2, 3 Resistor,.0K S Switch- Unit On/Off S4 Switch- Inverter Bypass S7 Switch- Local On/Off to MCB S2 Switch- Fan Door Interlock S40-45 Switch- UV Door Interlock T2 Transformer 5/24 VAC 75VA T3 Transformer 5/24 VAC 50VA WFS Switch, Water Flow (Code 24= ) ZNT Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj Sensor- Zone Temperature w/ Tenant Override 3770 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj COM BACnet MS/TP Communication Module (RSCOM485) BACnet /IP Communication Module (IP Cable 0 BaseT) LONMARK Space Comfort Controller (SCC) Communication Module LONMARK Discharge Air Controller (DAC) Communication Module Remote Keypad Interface In late 203, Digital Room Sensor p/n was added as the preferred option. The other Zone Temperature Sensors are still available as options. For positive p/n identification, refer to the drawings below. ZNT Sensor ZNT Sensor 3770 ZNT Sensor 3780 Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 37

38 Controls T Control Transformers 6/3 & Later Sch. Unit Cabinet No Heat/ Electric UV Part Sym. Size Size Description Lights 2 Heat 3 Lights 4 Number USED WITH 208V UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 500VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X USED WITH 230V UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 500VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X Code 04= *. 2 Code 39 CANNOT= E** AND Code 2= YY. 3 Code 39= E** AND Code 2= YY. 4 Code 2= UV AND Code 39 CANNOT= E**. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 38

39 Controls T Control Transformers, 6/3 & Later, Continued Sch. Unit Cabinet No Heat/ Electric UV Part Sym. Size Size Description Lights 2 Heat 3 Lights 4 Number USED WITH UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 50VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X USED WITH UNITS T S Transformer, 500VA X X T S Transformer, 750VA X T S, B Transformer, 750VA X X T S, B Transformer, 000VA X T B, M, L Transformer, 750VA X X T B, M, L Transformer, 500VA X T H Transformer, 750VA X X T H Transformer, 500VA X T L, H Transformer, 750VA X T L, H Transformer, 000VA X T L, H Transformer, 2000VA X T H Transformer, 000VA X T H Transformer, 500VA X T H Transformer, 2000VA X ALL ALL Finger Safe Cover X X X Code 04= *. 2 Code 39 CANNOT= E** AND Code 2= YY. 3 Code 39= E** AND Code 2= YY. 4 Code 2= UV AND Code 39 CANNOT= E**. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 39

40 Controls T Control Transformer Fuses- FA, FB, FC 6/3 & Later Sch. Unit Voltage Part Sym. Size Description 208V 230V Number USED WITH 500VA T TRANSFORMERS FA, B ALL Fuse- Midget, 6A X X FA, B ALL Fuse, Midget, 4A X FA, B ALL Fuse- Midget, 3A X FC ALL Fuse- Midget, 7A X X X X USED WITH 750VA T TRANSFORMERS FA, B ALL Fuse- Midget, 0A X FA, B ALL Fuse, Midget, 9A X FA, B ALL Fuse- Midget, 5A X FA, B ALL Fuse- Midget, 4A X FC ALL Fuse- Midget, 0A X X X X USED WITH 000VA T TRANSFORMERS FA, B ALL Fuse- Midget, 5A X FA, B ALL Fuse, Midget, 2A X FA, B ALL Fuse- Midget, 6A X FA, B ALL Fuse- Midget, 6A X FC ALL Fuse- Midget, 2A X X X X USED WITH 500VA T TRANSFORMERS FA, B ALL Fuse- Midget, 20A X FA, B ALL Fuse, Midget, 7.5A X FA, B ALL Fuse- Midget, 9A X FA, B ALL Fuse- Midget, 7A X FC ALL Fuse- Midget, 5A X X X X USED WITH 2000VA T TRANSFORMERS FA, B ALL Fuse- Midget, 30A X X FA, B ALL Fuse, Midget, 2A X FA, B ALL Fuse- Midget, 3A X FC ALL Fuse- Midget, 7A X X X X Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 40

41 Controls Compressor Contactor and Manual Motor Protector Layout Diagrams 6/3 & Later Phase Barrier Front Mtd. Aux. Contact 2 3E MMP 3 MMP 3 Front Mtd. Aux. Contact 2 Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact A 3B Link Contactor MMP- 8 & M- 8 Link Detail 6, 0 HP Cmprs.- 460/ 5 HP Cmprs.- MMP- 8 & M- 8 Link Detail 6, 0 HP Cmprs.- 3 HP Cmprs.- 460/ 5 HP Cmprs.- NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier Front Mtd. Aux. Contact 2 3E MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor MMP- 8 & M- 8 Link Detail 3, 5 HP Cmprs.- Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 4

42 Controls Compressor Contactor and Manual Motor Protector Components 6/3 & Later Compressor Ref. Sch. Part Part 6HP 0HP 3HP 5HP No. Sym. Description Number Code 6 Code 6 Code 6 Code 6 = A = C = D = E USED WITH 208V COMPRESSORS M- 8 Contactor, 40A Contactor, 50A Contactor, 65A Contactor, 80A A Auxiliary Contact 2/NC/2NO Auxiliary Contact NC or NO MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link Link E Phase Barrier N/S Dial Cover USED WITH 230V COMPRESSORS M- 8 Contactor, 40A Contactor, 65A Contactor, 65A A Auxiliary Contact 2/NC/2NO Auxiliary Contact NC or NO MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link Link E Phase Barrier N/S Dial Cover N/S= Not shown on diagram. Quantities shown are PER compressor. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 42

43 Controls Compressor Contactor and Manual Motor Protector Components, 6/3 & Later, Continued Compressor Ref. Sch. Part Part 6HP 0HP 3HP 5HP No. Sym. Description Number Code 6 Code 6 Code 6 Code 6 = A = C = D = E USED WITH COMPRESSORS M- 8 Contactor, 6A Contactor, 32A Contactor, 40A A Auxiliary Contact 2/NC/2NO Auxiliary Contact NC or NO Auxiliary Contact NC or NO MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector A Spacer B Link Link E Phase Barrier N/S Dial Cover Dial Cover USED WITH COMPRESSORS M- 8 Contactor, 2A Contactor, 6A Contactor, 25A Contactor, 32A A Auxiliary Contact 2/NC/2NO Auxiliary Contact NC or NO Auxiliary Contact NC or NO MMP- 8 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector A Spacer B Link Link E Phase Barrier N/S Dial Cover Dial Cover N/S= Not shown on diagram. Quantities shown are PER compressor. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 43

44 Controls Electric Heat 6/3 & Later 34KW Heater Element Components: (Code 39= E34) SCHEMATIC SYMBOL DESCRIPTION PART NO. QTY. 208V: FB3, FB32 FUSE BLOCK, 60A ON FB3, FB32 FUSE, 50A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 40A : FB3, FB32 FUSE BLOCK, 30A ON FB3, FB32 FUSE, 30A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 25A KW Heater Element Components: (Code 39= E68) SCHEMATIC SYMBOL DESCRIPTION PART NO. QTY. : FB3, FB32 FUSE BLOCK, 60A ON FB3, FB32 FUSE, 50A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 40A : FB3, FB32 FUSE BLOCK, 60A ON FB3, FB32 FUSE, 45A ON FB3, FB32 FUSE PULLER/COVER M3, M32 CONTACTOR, 25A For voltages not listed, contact Daikin Applied with model and serial number information so that the required part(s) can be identified. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 44

45 Controls Disconnect Switches 6/3 & Later Sch. Part Part Voltage Sym. Description Number 208V 230V Disconnect Switch DS, 2 Disconnect Switch Switch- 00A Handle Shaft Switch- 50A Handle Mechanism Shaft Lugs Switch- 250A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Switch- 800A Handle Mechanism Shaft Lugs Switch- 000A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed switch to verify the correct Disconnect size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 2 This shaft is 4.25 OAL and is designed to be cut to length in the field. 3 This shaft is 7.2 (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 45

46 Controls Fan Contactor and Motor Protector Configuration Diagrams 6/3 & Later Phase Barrier 3E MMP 3 Phase Barrier 3E MMP 3 MMP 3 Link 3B Contactor Link 3B 3A Spacer Contactor 3B Link Contactor MMP0 & M0 Link Detail 3, 5 HP Motors- 460/ 7.5 HP Motors- MMP0 & M0 Link Detail 3, 5 HP Motors- 7.5 HP Motors- 208/230/ 0 HP Motors- All Voltages 5, 20 HP Motors- MMP0 & M0 Link Detail 5 HP Motors- 208/230/ 20, 40 HP Motors- 25, 30 HP Motors- 460/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier 3E MMP 3 3 Circuit Breaker (not shown) Link 3B Contactor Terminal Block 4A Contactor 4 Overload 5 Bypass Contactor MMP0 & M0 Link Detail 20, 25, 30 HP Motors- 40 HP Motors- 50, 60 HP Motors- 460/ MMP0 & M0 Link Detail 40, 50, 60 HP Motors- M30B, I & MMP30 Detail ALL Motors- (Typical) M30B/M30I Bypass Contactors are installed similar to their standard Contactor counterpart. The drawing above shows a typical, but NOT the only possible, configuration. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 46

47 Controls Fan Motor Components 6/3 & Later 3 HP Motor- Code 9= H* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 2A Contactor 7A MMP0, 30 Motor Protector 7-0A Motor Protector 3.5-5A A Spacer B Link Link E Phase Barrier M30B, I Bypass Contactor 2A Bypass Contactor 7A N/S CB0 Circuit Breaker 5A N/S FB0 Fuseblock Fuse 5A Fuse 0A Fuse 7A Fuse Cover/Puller VFD0 VFD V 230V 5 HP Motor- Code 9= J* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 25A Contactor 6A Contactor 9A Contactor 7A MMP0, 30 Motor Protector - 6A Motor Protector 5.5-8A A Spacer B Link Link E Phase Barrier M30B, I Bypass Contactor 25A Bypass Contactor 6A Bypass Contactor 9A Bypass Contactor 7A N/S CB0 Circuit Breaker 5A N/S FB0 Fuseblock Fuse 25A Fuse 20A Fuse 0A Fuse Cover/Puller VFD0 VFD V 230V N/S= Not Shown on Diagram. All quantities are PER assembly. Use pc. for M0 and 2pc. for M30B, I. 2 pc. PER Fuse. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 4 for Inverter brand supplied. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 47

48 Controls Fan Motor Components, 6/3 & Later, Continued 7.5 HP Motor- Code 9= K* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 25A Contactor 2A Contactor 9A MMP0, 30 Motor Protector 20-25A Motor Protector 7-22A Motor Protector 9-2.5A Motor Protector 7-0A A Spacer B Link Link E Phase Barrier M30B, I Bypass Contactor 25A Bypass Contactor 2A Bypass Contactor 9A N/S CB0 Circuit Breaker 5A N/S FB0 Fuseblock Fuseblock Fuse 35A Fuse 5A Fuse Cover Fuse Cover/Puller VFD0 VFD HP Motor- Code 9= L* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 32A Contactor 6A Contactor 2A MMP0, 30 Motor Protector 27-32A Motor Protector 23-28A Motor Protector - 6A Motor Protector 9-2.5A A Spacer B Link E Phase Barrier M30B, I Bypass Contactor 32A Bypass Contactor 6A Bypass Contactor 2A N/S CB0 Circuit Breaker 5A N/S FB0 Fuseblock Fuseblock Fuse 50A Fuse 45A Fuse 20A Fuse Cover Fuse Cover/Puller VFD0 VFD N/S= Not Shown on Diagram. All quantities are PER assembly. Use pc. for M0 and 2pc. for M30B, I. 2 pc. PER Fuse. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 4 for Inverter brand supplied. 208V 208V 230V 230V Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 48

49 Controls Fan Motor Components, 6/3 & Later, Continued 5 HP Motor- Code 9= M* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 50A Contactor 25A Contactor 25A MMP0, 30 Motor Protector 36-45A Motor Protector 28-40A Motor Protector 4-20A Motor Protector - 6A A Spacer B Link Link E Phase Barrier M30B, I Bypass Contactor 50A Bypass Contactor 25A N/S CB0 Circuit Breaker 20A N/S FB0 Fuseblock Fuseblock Fuseblock Fuse 70A Fuse 60A Fuse 30A Fuse Cover Fuse Cover Fuse Cover/Puller VFD0 VFD HP Motor- Code 9= N* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 65A Contactor 32A Contactor 25A MMP0, 30 Motor Protector 45-63A Motor Protector 23-28A Motor Protector 8-25A A Spacer B Link Link Link E Phase Barrier Phase Barrier M30B, I Bypass Contactor 65A Bypass Contactor 32A Bypass Contactor 25A N/S CB0 Circuit Breaker 70A Circuit Breaker 60A Circuit Breaker 30A N/S FB0 Fuseblock Fuse 40A Fuse Cover VFD0 VFD N/S= Not Shown on Diagram. All quantities are PER assembly. Use pc. for M0 and 2pc. for M30B, I. 2 pc. PER Fuse. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 4 for Inverter brand supplied. 208V 208V 230V 230V Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 49

50 Controls Fan Motor Components, 6/3 & Later, Continued 25 HP Motor- Code 9= P* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 80A Contactor 40A Contactor 32A MMP0, 30 Motor Protector 57-75A Motor Protector 45-63A Motor Protector 22-32A B Link Link Link E Phase Barrier M30B, I Bypass Contactor 80A Bypass Contactor 32A N/S CB0 Circuit Breaker 90A Circuit Breaker 80A Circuit Breaker 40A N/S FB0 Fuseblock Fuse 50A Fuse Cover VFD0 VFD 208V 230V 30 HP Motor- Code 9= Q* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 95A Contactor 80A Contactor 40A Contactor 32A MMP0, 30 Motor Protector 70-90A Motor Protector 28-40A Motor Protector 22-32A B Link Link Link E Phase Barrier M30B, I Bypass Contactor 95A Bypass Contactor 80A Bypass Contactor 40A N/S CB0 Circuit Breaker 25A Circuit Breaker 90A Circuit Breaker 40A N/S FB0 Fuseblock Fuse 60A Fuse Cover VFD0 VFD 208V 230V N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 4 for Inverter brand supplied. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 50

51 Controls Fan Motor Components, 6/3 & Later, Continued 40 HP Motor- Code 9= R* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 5A Contactor 65A Contactor 50A MMP0, 30 Circuit Breaker 50A Motor Protector 36-50A Motor Protector 28-40A B Link Link C Lugs- Supply Fan MMP0 (kit of 3pc.) E Phase Barrier OL0 Overload A A Terminal Block M30B, I Bypass Contactor 5A Bypass Contactor 65A Bypass Contactor 50A N/S Mechanical Interlink, Bypass Contactor N/S CB0 Circuit Breaker 50A Circuit Breaker 25A Circuit Breaker 60A Circuit Breaker 50A N/S Lugs- Supply Fan CB0 (kit of 3pc.) VFD0 VFD 208V 230V 50 HP Motor- Code 9= S* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 50A Contactor 65A MMP0, 30 Circuit Breaker 50A Motor Protector 45-63A Motor Protector 36-50A B Link E Phase Barrier OL0 Overload A A Terminal Block M30B, I Bypass Contactor 50A Bypass Contactor 65A N/S Mechanical Interlink, Bypass Contactor N/S CB0 Circuit Breaker 80A Circuit Breaker 60A N/S FB0 Fuseblock Fuse 225A Fuse 75A VFD0 VFD 208V 230V N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 4 for Inverter brand supplied. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 5

52 Controls Fan Motor Components, 6/3 & Later, Continued 60 HP Motor- Code 9= T* Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor 85A Contactor 80A Contactor 65A MMP0, 30 Circuit Breaker 225A Motor Protector 70-90A Motor Protector 45-63A B Link E Phase Barrier OL0 Overload A A Terminal Block M30B, I Bypass Contactor 85A Bypass Contactor 80A Bypass Contactor 65A N/S Mechanical Interlink, Bypass Contactor N/S CB0 Circuit Breaker 90A Circuit Breaker 80A N/S FB0 Fuseblock Fuse 300A VFD0 VFD 208V 230V N/S= Not Shown on Diagram. All quantities are PER assembly. Refer to the Inverter Section for VFD p/ns. Reference Code 4 for Inverter brand supplied. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 52

53 Refrigeration & Water Components Condenser & Compressor Layout Diagrams Condenser Stack Compressors: Three compressor unit shown Condenser Stack Compressors: Eight compressor unit shown The above diagrams show typical component locations. The number and layout of components will vary depending upon unit cabinet size and the number of refrigeration circuits. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 53

54 Refrigeration & Water Components Condensers CIRCUIT UNIT SIZE CONDENSER NO. PART NO Normal orientation Modified orientation Note that for certain unit sizes 050H and smaller the orientation of the Condenser Head of the lower (bottom) Condenser needs to be changed to fit onto the piping assembly. If this is the case, the head must be removed, flipped in orientation, and reassembled. If the Head Gasket needs to be replaced use p/n E Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 54

55 Refrigeration & Water Components Condenser Components Ref. Unit Part Quantity Per No. Size Description No. Condenser ALL Pressure Relief Valve ALL Seal, Rotolock ALL Seal, Rotolock ALL Condenser Vessel Head Gasket E ALL Head Gasket Bolts ALL Fitting, Victaulic ALL Clamp, Victaulic Fitting The above diagrams show typical component locations. The total number and layout of components will vary depending upon unit cabinet size and the number of refrigeration circuits. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 55

56 Refrigeration & Water Components Liquid Line Layout Diagrams Liquid Line LH Two Compressor Circuit #2 shown 2 See Detail Below Liquid Line RH Eight Compressor unit shown Liquid Line LH Three Compressor unit shown The above diagrams show typical component locations. The total number and layout of components will vary depending upon unit cabinet size and the number of refrigeration circuits. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 56

57 Refrigeration & Water Components Suction Line Layout Diagrams Suction Line RH Three Compressor Circuit #2 shown 6 See Detail Below Suction Line Schrader Relief Valve The above diagrams show typical component locations. The total number and layout of components will vary depending upon unit cabinet size and the number of refrigeration circuits. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 57

58 Refrigeration & Water Components Discharge Line Layout Diagrams Suction Line LH Eight Compressor Circuit #6 shown See Detail Below Discharge Line LH Eight Compressor Circuit #6 shown 0 2 The above diagrams show typical component locations. The total number and layout of components will vary depending upon unit cabinet size and the number of refrigeration circuits. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 58

59 Refrigeration & Water Components Thermal Expansion Valves Thermal Expansion Valves (TEV)- Single Circuit Units Code 2= S Ref. Unit Cabinet Size Coil Size Circuit Part Part No. Size Code 04= Code 03= No. Description No. 02 S S, 2 Thermal Exp. Valve 8T S S Thermal Exp. Valve 8T S S 2 Thermal Exp. Valve 2.5T S S, L Thermal Exp. Valve 8T S S, L 2 Thermal Exp. Valve 20T S S, L Thermal Exp. Valve 2.5T S S, L 2 Thermal Exp. Valve 20T S S, L, 2 Thermal Exp. Valve 20T B S, L, 2 Thermal Exp. Valve 2.5T B S, L 3 Thermal Exp. Valve 20T B, M S, L Thermal Exp. Valve 2.5T B, M S, L 2, 3 Thermal Exp. Valve 20T B, M S, L thru 3 Thermal Exp. Valve 20T M S, L thru 4 Thermal Exp. Valve 5T M, L S, L, 2 Thermal Exp. Valve 5T M, L S, L 3, 4 Thermal Exp. Valve 20T M, H S, L thru 4 Thermal Exp. Valve 20T L, H S thru 4 Thermal Exp. Valve 2.5T L, H S 5, 6 Thermal Exp. Valve 5T L, H S, 2 Thermal Exp. Valve 2.5T L, H S 3 thru 6 Thermal Exp. Valve 5T L, H S thru 6 Thermal Exp. Valve 5T H S, L thru 6 Thermal Exp. Valve 20T H S, L thru 8 Thermal Exp. Valve 5T L, H S, L thru 4 Thermal Exp. Valve 5T L, H S, L 5 thru 8 Thermal Exp. Valve 20T L, H S, L thru 8 Thermal Exp. Valve 20T Quantity is one per circuit/compressor. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 59

60 Refrigeration & Water Components Miscellaneous Refrigeration Components Ref. Unit Part Quantity Per No. Size Description No. Condenser 2 ALL Liquid Line Filter Drier ALL Liquid Line Sight Glass ALL Fitting, Angle ALL Liquid Line Shut-Off Valve ALL Suction Service Valve ALL Core, Suction Line Schrader Valve ALL Stem, Suction Line Schrader Valve ALL Cap, Suction Line Schrader Valve ALL Adapter ALL Schrader Valve, Discharge ALL Discharge Service Vlv. (6HP Compr.) /2 & Earlier ALL Discharge Service Vlv. (6HP Compr.) 2/2 & Later ALL Discharge Service Vlv. (7HP, 0-5HP Compr.) N/S ALL Valve, Hot Gas Bypass N/S= Not shown on diagram. Quantity of IF Code 42=. 2 Quantity of IF Code 42=, quantity of 2 IF Code 42=2, Y. 3 Quantity of IF Code 3= H. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 60

61 Refrigeration & Water Components Water Valves, & Actuator: Code 36= OR Code 37= *, *2 Water Valves, & Actuator There have been several significant redesigns of the Water Valve and Actuator assembly. To ensure that the correct part(s) are selected contact Daikin Applied with model and Serial Number information. Typical (but not the only possible) assembly configurations are shown below. Actuator Actuator Brackets Bearing Bracket Shaft Shaft Water Valve Water Valve Victaulic Clamps Typical Water Supply Line Piping Six or Eight Compressor unit shown Actuator EWT Sensor Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 6

62 Compressors Compressor Configurations Cabinet Size Nominal Tons Compressor Config. Compressor Combination Code 04= Code 6= Small 02 AAYYYYYY 6 & 6 Code 04= S 08 ACYYYYYY 6 & AEYYYYYY 6 & CEYYYYYY 0 & EEYYYYYY 5 & 5 Small Tall 039 CCEYYYYY 0 & 0 & 5 Code 04= B 044 CEEYYYYY 0 & 5 & EEEYYYYY 5 & 5 & 5 Medium 044 CEEYYYYY 0 & 5 & 5 Code 04= M 050 EEEYYYYY 5 & 5 & DDDDYYYY 3 & 3 & 3 & DDEEYYYY 3 & 3 & 5 & EEEEYYYY 5 & 5 & 5 & 5 Large 062 DDEEYYYY 3 & 3 & 5 & 5 Code 04= L 073 CCCCDDYY 0 & 0 & 0 & 0 & 3 & CCDDDDYY 0 & 0 & 3 & 3 & 3 & DDDDDDYY 3 & 3 & 3 & 3 & 3 & EEEEEEYY 5 & 5 & 5 & 5 & 5 & 5 Large Tall 065 EEEEYYYY 5 & 5 & 5 & 5 Code 04= H 073 CCCCDDYY 0 & 0 & 0 & 0 & 3 & CCDDDDYY 0 & 0 & 3 & 3 & 3 & DDDDDDYY 3 & 3 & 3 & 3 & 3 & EEEEEEYY 5 & 5 & 5 & 5 & 5 & 5 05 DDDDDDDD 3 & 3 & 3 & 3 & 3 & 3 & 3 & 3 20 DDDDEEEE 3 & 3 & 3 & 3 & 5 & 5 & 5 & 5 30 EEEEEEEE 5 & 5 & 5 & 5 & 5 & 5 & 5 & 5 These are the STANDARD Compressor combinations. Note that other configurations ARE possible. Confirm which compressors were specified by referencing Code 6. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 62

63 Compressors Independent Refrigeration Circuit: Code 2= S Unit Size- Quantity in Unit Ref Part Circuit Code No. Number No. 6= , 2 A , 2 A , 2 A A A A C C C C A A E E E 3090 C C C E E E , 2 E , 2 E , 2 E , 2 C , 2 C , 2 C E E E 3090 C C C , 3 E , 3 E , 3 E 2 These are the STANDARD Compressor combinations. Note that other configurations ARE possible. Confirm which compressors were specified by referencing Code 6. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 63

64 Compressors Independent Refrigeration Circuit: Code 2= S, Continued Unit Size- Quantity in Unit Ref Part Circuit Code No. Number No. 6= E E E D D D , 2 D , 2 D , 2 D , 4 E , 4 E , 4 E E E E C C C D D D , 2 C , 2 C , 2 C D D D D D D 6 These are the STANDARD Compressor combinations. Note that other configurations ARE possible. Confirm which compressors were specified by referencing Code 6. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 64

65 Compressors Independent Refrigeration Circuit: Code 2= S, Continued Unit Size- Quantity in Unit Ref Part Circuit Code No. Number No. 6= E E E D D D D D D E E E E E E 8 These are the STANDARD Compressor combinations. Note that other configurations ARE possible. Confirm which compressors were specified by referencing Code 6. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 65

66 Fan Motors & Inverters Motors H.P. Unit ODP PrEff. TEFC PrEff Voltage C9= *S C9= *T C05= /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ C05= /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ C05= /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ C05= /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ /60/ Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 66

67 Fan Motors & Inverters Inverters ABB VFD: Code 4= 3, A Motor Horsepower Part Number The replacement keypad/display p/n is Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 67

68 Fan Motors & Inverters Inverters, Continued Dan Foss VFD: Code 4=, G Motor Horsepower Part Number Contact Daikin Applied with model and serial number information so that the needed part(s) can be identified. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 68

69 Fan Motors & Inverters Inverters, Continued MD2, MD3, MD6 VFD: Code 4= 4, 5, Q, S Motor Horsepower Part Number , , , , , , Early production units shipped with ATV2 VFDs. All ATV2 drives have been replaced with ATV22 drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV2 Remote Keypad is p/n The ATV2 Lonworks communication card is p/n The ATV22 Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The ATV22 Lonworks communication card is p/n All other ATV22 communication cards are integral to the VFD and are not available separately. Note that since the original ATV2 drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV2 part fails, the entire drive must be replaced. 2 MD3 Remote Keypad p/n is For units with an MD3 inverter and motor 20 HP or smaller a Line Reactor will be automatically installed. See the table one page after next for Line Reactor part numbers. 4 MD6 Remote Keypad p/n is plus Mount p/n Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 69

70 Fan Motors & Inverters Inverters, Continued MD4, MD5 VFD: Code 4= 6, B Motor Horsepower Part Number The replacement VFD Keypad Display is p/n Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 70

71 Fan Motors & Inverters Fan Motor Line Reactors Motor Horsepower Part Number Line reactors are optional for all voltages and motor sizes EXCEPT, for units built 5/3 & Earlier, units using 3HP thru 20HP motors have a line reactor installed automatically. 2 These are 5% impedance line reactors. Some units may have had 3% impedance line reactors installed, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. 3 Not available for this HP and voltage. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 7

72 Fan Section Fan Assembly Diagrams Typical Plenum Fan Diagram: 3" thru 30" Wheel Bearing, Opposite Drive Side Bearing, Drive Side Shaft Fan Wheel Inlet Funnel Motor (See Motor Section) Typical Plenum Fan Diagram: 33" thru 44" Wheel Bearing, Opposite Drive Side Inlet Funnel Fan Wheel Shaft Bearing, Drive Side Motor (See Motor Section) Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 72

73 Fan Section Fan Wheels & Shafts Fan Wheels Cabinet Size Fan Type Part Part Quantity Code 04= Code 8= Description No. S 2B 3.5" SWSI- 9 Blade, Aluminum S 2Q 3.5" SWSI- 2 Blade, Aluminum S 5B 5" SWSI- 9 Blade, Aluminum S 5Q 5" SWSI- 2 Blade, Aluminum S, B, M 8B 8" SWSI- 9 Blade, Aluminum S, B, M 8Q 8" SWSI- 2 Blade, Aluminum S, B, M 20B 20" SWSI- 9 Blade, Aluminum S, B, M 20Q 20" SWSI- 2 Blade, Aluminum S, B, M, L 22B 22" SWSI- 9 Blade, Aluminum S, B, M, L 22Q 22" SWSI- 2 Blade, Aluminum S, B, M, L, H 25B 24.5" SWSI- 9 Blade, Aluminum S, B, M, L, H 25Q 24.5" SWSI- 2 Blade, Aluminum B, M, L, H 27B 27" SWSI- 9 Blade, Steel B, M, L, H 27Q 27" SWSI- 2 Blade, Steel M, L, H 30B 30" SWSI- 9 Blade, Steel M, L, H 30Q 30" SWSI- 2 Blade, Steel M, L, H 33B 33" SWSI- 9 Blade, Steel M, L, H 33Q 33" SWSI- 2 Blade, Steel M, L, H 37B 36.5" SWSI- 9 Blade, Steel M, L, H 37Q 36.5" SWSI- 2 Blade, Steel H 40B 40" SWSI- 9 Blade, Steel H 40Q 40" SWSI- 2 Blade, Steel H 44B 44" SWSI- 9 Blade, Steel H 44Q 44" SWSI- 2 Blade, Steel Fan Shafts Wheel Shaft Part Description Diameter No. 3 Wheel.9 Dia Wheel.9 Dia Wheel.9 Dia Wheel.44 Dia Wheel.44 Dia Wheel.69 Dia Wheel.69 Dia Wheel.69 Dia Wheel.94 Dia Wheel 2.9 Dia Wheel 2.9 Dia Wheel 2.9 Dia Wheel 2.44 Dia Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 73

74 Fan Section Bearings & Drive Packages Fan Bearings: Drive Side Wheel Bearing Part Description Description No. 3 Wheel Bearing, Ball.88" Wheel Bearing, Ball.88" Wheel Bearing, Ball.88" Wheel Bearing, Ball.438" Wheel Bearing, Ball.438" Wheel Bearing, Ball.688" Wheel Bearing, Ball.688" Wheel Bearing, Ball.688" Wheel Bearing, Ball.938" Wheel Bearing, Roller 2.88" Wheel Bearing, Roller 2.88" Wheel Bearing, Roller 2.88" Wheel Bearing, Roller 2.438" Fan Bearings: Opposite Drive Side Wheel Bearing Part Description Description No. 3 Wheel Bearing, Ball.88" Wheel Bearing, Ball.88" Wheel Bearing, Ball.88" Wheel Bearing, Ball.438" Wheel Bearing, Ball.438" Wheel Bearing, Ball.688" Wheel Bearing, Ball.688" Wheel Bearing, Ball.688" Wheel Bearing, Ball.938" Wheel Bearing, Ball 2.88" Wheel Bearing, Ball 2.88" Wheel Bearing, Ball 2.88" Wheel Bearing, Ball 2.438" Note that early units may have used setscrew locking type bearings. The concentric locking collar style bearings listed are the recommended replacements in all cases. Drive Packages Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 74

75 Fan Section Isolator Layout Diagram & Rubber-In-Shear (RIS) Vibration Isolators: Code 4= 3 Isolator Layout Diagram Thrust Restraint RIS/Spring Isolator RIS (Rubber-In-Shear) Isolators Fan Sizes Part Rubber Isolator Part Quantity Used with Description Color No " RIS Mount, 35 lb. Blue " RIS Mount, 45 lb. Black " RIS Mount, 70 lb. Red " RIS Mount, 20 lb. Green " RIS Mount, 35 lb. Blue " RIS Mount, 70 lb. Black " RIS Mount, 240 lb. Red " RIS Mount, 380 lb. Green " RIS Mount, 550 lb. Gray Quantity and location of each isolator used depends upon the motor and drive package selected. Visually confirm the color and location where the required isolator is used in the assembly before ordering, or contact Daikin Applied with model and serial number information so that the correct isolator(s) can be identified. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 75

76 Fan Section Spring Vibration Isolators, Non-Seismic: Code 4= 2 Fan Sizes Part Spring(s) Part Quantity Used with Description Color 2 No " Spring mount, 60 lb. Yellow w/ Brown Markings " Spring mount, 90 lb. Blue " Spring mount, 20 lb. Black " Spring mount, 75 lb. Dark Green " Spring mount, 250 lb. Green " Spring mount, 330 lb. Yellow " Spring mount, 450 lb. Yellow " Spring mount, 600 lb. Orange " Spring mount, 750 lb. White , 44" Spring mount, 50 lb. Blue , 44" Spring mount, 276 lb. Black , 44" Spring mount, 426 lb. Outer Black/Inner Blue , 44" Spring mount, 500 lb. Red , 44" Spring mount, 650 lb. Outer Red/Inner Blue , 44" Spring mount, 776 lb. Outer Red/Inner Black , 44" Spring mount, 000 lb. Green Quantity and location of each isolator used depends upon the motor and drive package selected. Visually confirm the color and location where the required isolator is used in the assembly before ordering, or contact Daikin Applied with model and serial number information so that the correct isolator(s) can be identified. 2 Spring colors may vary dictated by vendor updates. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 76

77 Fan Section Seismic Spring Vibration Isolators: Code 4= Fan Sizes Part Spring(s) Part Quantity Used with Description Color 2 No " Seismic mount, 33 lb. Yellow " Seismic mount, 43 lb. Purple " Seismic mount, 59 lb. Black w/ Silver Markings " Seismic mount, 83 lb. Red w/ White Markings " Seismic mount, 20 lb. Green " Seismic mount, 55 lb. Black w/ Yellow Markings " Seismic mount, 95 lb. Gray " Seismic mount, 236 lb. Gray & Green w/ White Markings " Seismic mount, 300 lb. Gray w/ White Markings & Black " Seismic mount, 390 lb. 2 Gray " Seismic mount, 472 lb. 2 Gray w/ White Markings " Seismic mount, 600 lb. 2 Gray w/ White Markings & Black , 44" Seismic mount, 2 lb. Brown , 44" Seismic mount, 7 lb. White w/ Yellow Markings , 44" Seismic mount, 24 lb. Red , 44" Seismic mount, 348 lb. Green w/ Yellow Markings , 44" Seismic mount, 453 lb. Blue , 44" Seismic mount, 590 lb. White w/ Sliver Markings , 44" Seismic mount, 676 lb. Green & White , 44" Seismic mount, 767 lb. White w/ Sliver Markings & Silver Quantity and location of each isolator used depends upon the motor and drive package selected. Visually confirm the color and location where the required isolator is used in the assembly before ordering, or contact Daikin Applied with model and serial number information so that the correct isolator(s) can be identified. 2 Spring colors may vary dictated by vendor updates. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 77

78 Fan Section Thrust Restraint Isolators & Inlet Funnels Thrust Restraint Isolators Fan Sizes Part Part Used With Description No. 3-44" Spring Mount 200 lb " Spring Mount 250 lb " Spring Mount 300 lb " Spring Mount 350 lb " Spring Mount 450 lb " Spring Mount 600 lb Inlet Funnels Part Wheel Part Description Description No. Inlet Funnel 3 Wheel Inlet Funnel 5 Wheel Inlet Funnel 6 Wheel Inlet Funnel 8 Wheel Inlet Funnel 20 Wheel Inlet Funnel 22 Wheel Inlet Funnel 24 Wheel Inlet Funnel 27 Wheel Inlet Funnel 30 Wheel Inlet Funnel 33 Wheel Inlet Funnel 36 Wheel Inlet Funnel 40 Wheel Inlet Funnel 44 Wheel Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 78

79 Electric Heater Elements & Hot Water Heating Coils Electric Heater Element Electric Heater Elements Cabinet Size Element Part Part Quantity 34KW Quantity 68KW Code 04= Voltage Description No. Code 39= E34 Code 39= E68 S, B 240V 34KW Element, 8" x 28" NA S, B 480V 34KW Element, 8" x 28" NA S, B 600V 34KW Element, 8" x 28" NA M 240V 34KW Element, 24" x 37" NA M 480V 68KW Element, 24" x 37" NA M 600V 68KW Element, 24" x 37" NA L,H 240V 68KW Element, 29" x 45" NA L,H 480V 68KW Element, 29" x 45" NA L,H 600V 68KW Element, 29" x 45" NA Hot Water Heating Coils Hot Water Heating Coils are serial number specific. Contact Daikin Applied with model and Serial Number information in order to identify the required coil. Self-Contained; SWP Vintage H Rev. I /7 RPL / Page 79

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018 Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B Replacement Parts List No. 0700053000 Revision C 02/2018 Daikin Magnitude TM Magnetic Bearing Centrifugal Chiller WME 0501S, 0502S, 0701S, 0702S Vintage B To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55)

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55) Replacement Parts List No. 70008600 Revision M /207 Daikin McQuay Global Scroll Compressor Air-Cooled Chiller AGZ 025-90 Vintage D Unit Revision 00, 0A (Code 55) To find your Daikin Applied parts distributor,

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019 Replacement Parts List No. 700052600 Revision G 0/209 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017 Replacement Parts List No. 700005800 Revision J 12/2017 McQuay Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4 Replacement Parts List No. 700050500 Revision G 07/2018 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 3 009, 012 Design 4 To find your Daikin Applied parts distributor,

More information

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005 Replacement Parts List No. 700005500 Revision J 10/2017 McQuay Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller WMC 150 Vintage A Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W Replacement Parts List No. 70005300 Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT 045-074 Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor,

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101700 Revision B 02/2017 McQuay Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 015-019 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998 Replacement Parts List No. 057101600 Revision E 06/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B Last Manufactured: 1998 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018 Replacement Parts List No. 700052900 Revision C 0/208 Daikin TrailBlazer Air-Cooled Scroll Chiller AMZ 00-040 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE A WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: 150.7-RP1 (709) Form: 150.7-RP1 (810) MODELS YCRL0064, 0074, 0084, 0096, 0118, 016, 0156, 0177, 0198, 000, 030, 060, 0300, 0345, 0385,

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101500 Revision B 02/2017 AAF Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 006-012 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL DC FREE COOLING UNIT SYSTEM AIR CONDITIONER MODELS DAPA DLPA DAPA DLPA DAPB DLPB CONTROLLER MODELS LC00 LC0 LC000 Description Page Cabinet Components Exploded View... Usage List...

More information

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001 Replacement Parts List No. 1105050 New 05/2001 McQuay Thermal Systems Absorption Chiller ME, MF 21-33 Vintage A Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information