Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Size: px
Start display at page:

Download "Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models"

Transcription

1 Replacement Parts List No Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS Tons Vintage D Unit Model Code 44= R, D To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 5 Nomenclature Electrical Legend Section A- Outdoor/Return Air Section Notes % Outside Air Damper with Hood- No Return Air Plenum % Outside Air Damper Detail w/ ACT3...,. 0-30% Outside Air Section w/ ACT3... 3, % Economizer Section with Exhaust Damper- Units w/o Return Air Fans % Economizer Section with Exhaust Damper- Units w/ 40 Return Air Fans % Economizer Section with Prop Exhaust Fan & Damper % Economizer Damper w/ ACT3- Diagrams % Economizer Damper w/ ACT3- Components... 9 California Title 4 Assembly: Code 33 (Mid 0 & Later) = *F*** Return Air Plenum Isolation Damper w/ Actuator ACT Prop Exhaust Fan & Damper Detail Design Flow Detail Return Air Fan: Code = 40B* Return Air Fan Mounts: Code = 40B* Return Air Fan Motors... 38, 39 Section Mounted Controls- OAE, RAE, LT, S, REC Section A- Outdoor/Return Air w/ Heat Recovery Section Notes... 4 Cabinet Gaskets, Doors, Hardware, Exhaust Hoods... 4 Base Components, Hood, Dampers Return Air Fan Detail Low Leak Damper Detail Bypass L Type Damper Detail Heat Recovery/Enthalpy Wheel, Motor, Drive Components, Seals AFD60 Frost Protection Inverter: Code 4= F... 5 Section Mounted Controls- OAE, RAE, RAT, EAT, LAT... 5 Section Mounted Controls- SD, HUM, LT, S, REC Section B- DrawThru Filter/Blank Section Notes Section Mounted Controls- PC5, LT3, S3, REC Filters Air Blender Section Components Magnehelic/Differential Pressure Gauges Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes Section Mounted Controls- LT, S, REC Section D- DrawThru Cooling Section Notes Section, Small Face Coils Section, Large Face Coils Section E- Spacer Section & Section E- DrawThru Heat Section Notes Section Mounted Controls- LT8, REC8, S8- Section Mounted Light Hot Water OR Steam Coil Heat, Mixing Valves & Actuator VM... 6 Section F- Supply Air Section Notes... 6 Forward Curved Fans- Low Pressure- FCLP Forward Curved Fans- High Pressure- FCMP Air Foil Fan- Double Width Air Foil Fan- Single Width- RDT Units Fan Mounts- 7 Forward Curved Fan Fan Mounts- 7 Airfoil Double Width Fan Fan Mounts- 30 Airfoil Double Width Fan Fan Mounts- 33 Airfoil Double Width Fan Fan Mounts- 40 AFSW- RDT Units... 7 Fan Mounts- 44 AFSW- RDT Units... 7 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

3 Contents Continued Section F- Supply Air Section, Continued Supply Air Fan Motors... 73, 74 Belt Guards Inverters & Inverter Bypass Control Box Motor HP , 77 Motor HP Motor HP Inverters Line Reactors... 9 Section Mounted Controls- PC7, HL, LT0, S0, REC0, UV Lights... 9 Section Mounted Controls- MAT, EFT, SAT, DAT, OAT, SD Section Mounted Controls- SCB- Split Junction Box- TB5, TB7, TB8, PB0, PB9, PB0, PB Section G- BlowThru Heat Section Notes Option : Blank/Empty Section Diffuser Option : Hot Water OR Steam Coil Heat Mixing Valves and Actuator VM Option 3: Electric Heat Heaters, Diffusers, Hi Limit Cutouts HL- 0, , 98 Electric Heat Control Box- 03/3 & Earlier Electric Heat Control Box- 04/3 & Later Option 4- Gas Heat Heat Exchangers & Vestibules- 00, 50 MBH Furnaces Heat Exchangers & Vestibules- 30, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces... 0 Modulating Burner Hi Turn Down Burner Modulating Burner Controls No Controls- Diagram... 8 No Controls- Components... 9 MicroTech III Controls... 0 Hi Turn Down Burner Controls No Controls- Diagram... No Controls- Components... MicroTech III Controls... 3 Gas Train- Inlet Gas Train- Controls: GV,GV, GV3, GV4, GV5, GV6, VM Gas Train- Outlet Gas Train- Damper Linkage... 3 Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting... 3, 33 Section H- BlowThru Heat Blank Access Section Notes Access Door Latching Assemblies, Key, & Lock (All Sections) Section I- BlowThru Cooling Section Notes Section Mounted Controls- LT6, S6, REC Section J- Final Filter Section Notes Section Mounted Controls- HL3, PC Filters... 37, 38 Section K- Discharge Plenum Section- RPS OR RFS Notes Section Mounted Controls- OAT, DAT, SD Discharge Damper Assembly w/ Actuator ACT Section L- Out-of-Airstream Blank Access Section Notes... 4 Section Mounted Controls- LT0, REC0, S Section M- Condenser Section Notes... 4, 43 Condenser Fan Deck Assembly D: Code 47=,... 44, 45 Condenser Fan Deck Assembly D: Code 47=,... 46, 47 Quiet Fan Assembly: Code 47= 3, Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

4 Contents Continued Section M- Condenser Section, Continued Standard Compressors & Compressor Components: Code 44=R OR D Unit Size 045D Unit Size 050, 05D Unit Size D... 5 Unit Size 068D... 5 Unit Size D Digital Compressors & Components: Code 44= R AND Code 60= XX OR Code 44= D... 54, 55 RCS Pressure Manifolds- PC3, PC3, HP, HP, LP, LP, SPTRL... 56, 57 RPS/RDT Pressure Controls Box- AFD, AFD, LR, LR, LP, LP, HP, HP RCS Condenser Control Box Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C Section N- Main Control Box Notes Control Box Component Label Diagram Control Panel Units with No Controller: Code = Y*... 69, 70 Control Panel: (03/3 & Earlier) MicroTech III Units with Controller: Code = *E, *F, *W Control Panel: (04/03 & Later) MicroTech III Units with Controller: Code = *E, *F, *W Power Panel: (03/3 & Earlier) Power Panel Diagram Terminal Blocks, T Transformer & Fusing Fusing, Phase Protection, Ground Fault, Power Blocks Power Blocks continued, Receptacle, Disconnect Switch DS... 80, 8 Disconnect Switch DS, Circuit Breakers CB0, Circuit Breakers CB0, 0 continued, Plugs Supply MMP0 & M0 Fan Contactor and Return MMP0 & M0 Fan Contactor Compressor MMP- 4 and Contactor M- 4 Unit Size 045D Unit Sizes 050D, Unit Sizes 060D- 063D... 9 Unit Size 068D... 9 Unit Sizes 070, 07D Unit Size 075D Unit Size 079D Condenser Fan Contactors, MMPs, & Fusing... 96, 97 Heat Recovery Wheel MMP60 and Contactor M Power Panel: (04/03 & Later) Power Panel Diagram Terminal Blocks, T Transformer & Fusing Fusing, Phase Protection, Ground Fault, Power Blocks... 0 Power Blocks, continued, Receptacle, Plugs... 0 Disconnect Switch DS, Supply MMP0 & M0 Fan Contactor, Return MMP0 & M0 Fan Contactor Diagrams Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components Compressor Motor Protector MMP- 4, & Contactor M- 4 Unit Size 045D... Unit Size 050, 05D Unit Size D... 4 Unit Size 068D... 5 Unit Size 070, 07D... 6 Unit Size 075D... 7 Unit Size 079D... 8, 9 Condenser Fan Contactors, MMPs, & Fusing... 0, Energy Recovery Wheel Contactors, MMPs, & Fusing... Intelligent Equipment... 3 Section O- Refrigeration Tubing Notes... 4 Refrigeration Tubing Diagram... 4, 5 Valves, Filter Driers, Sight Glasses, & Hot Gas Bypass/Liquid Line Kits... 6, 7 Hot Gas Reheat... 8 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

5 Parts List Revision History Rev. Date Description A- AM 04/6 Archived Revisions A thru AG. AN 06/7 Page 7-3: Misc. updates/corrections/additions. Page 5-8: Added misc. descriptions to Legend. Page 9, 4, 5, 57, 58, 60, 35, 36, 4, 3 (OLD) 9, 4, 54, 59, 60, 6, 35, 36, 4, (NEW): Rewrote Notes. Page 6: Updated dwg. Changed Bub # to 60. Rewrote pg. header. Corrected dmpr. coding. Updated the TOC. Page 7: Updated dwgs. Changed bub. for Ref # 6 Fan Assy. to Ref # 40 per BOM. Added Grd. Fan Assys. Page 3: Updated Fan/hood dwg. Changed Bub # 6 to 40 & 6A to 40A. Added Grd. Fan Assys. Page 34: Rewrote footnote & Updated footnote notation. Page 35: Added JE, JY to pg. header. Added Note. Page 36, 37: Swapped pg. positions. Rewrote pg. headers. Updated the TOC. Page 37: Updated dwg. Removed unused VIV Fan info & updated p/n table & coding. Page 38, 73: Corrected coding. Page 40, 50 (OLD) 40, 5 (NEW): Rewrote footnote #. Page 43: Corrected Ref. #30 description. Page 46, 47 (NEW): Added pgs. for / & Later 40 SAF. Repaginated form & updated the TOC. Page 46 (OLD) 48 (NEW): Deleted out-effected actuator p/n. Rewrote footnotes. Page 49 (OLD) 5 (NEW): Updated dwg. Rewrote footnote #. Page 5 (OLD) 53 (NEW): Updated HUM p/ns. Page 54 (OLD) 56 (NEW): Updated dwgs., table headers, & p/ns. Page 55 (OLD) 57 (NEW): Updated VFD dwg. Page 57 (OLD) 59 (NEW): Changed Aux Drain Pan p/n to & updated coding, rewrote footnotes. Page 59 (OLD) 6 (NEW): Updated Ref #, 3 HW Coil p/ns. Added footnote # & footnote notation. Page 6-63 (OLD) (NEW): Misc. p/n updates/corrections. Page 66, 67 (OLD) 68, 69 (NEW): Deleted pgs. Repaginated form & updated the TOC. Page 67-7: Misc. p/n updates/corrections. Page 86-88, 90: Rewrote table headers. Page 89: Rewrote table header & footnote #. Page 9: Changed Lamp to Bulb or Fixture. Page 96: Added Freezestat FS p/n Page 09, 0: Updated/added dwgs. & p/ns. Rewrote footnotes & footnote notation. Page, 3: Misc. updates. Page 9, 0,, 3: Updated Ref. #34 TB p/ns & qtys. Added footnote. Page 4-6, 8, 30: Updated misc. pns. Page 3: Updated/corrected Ref. #95 VM p/ns. Rewrote footnotes. Page 3, 33: Misc. p/n & Bub. updates. Page 34: Updated Latching Assy. descriptions. Rewrote footnote #. Page 36: Corrected Section Mounted Controls coding in section header. Page 43: (NEW): Added pg. for additional Notes. Repaginated form & updated the TOC. Page (OLD) (NEW): Updated dwgs, headers, footnotes, & misc. p/ns. Page 53: Added footnote #3. Page 54, 55 (NEW): Added pgs. for Digital Cmprs. & Components. Repaginated form & updated the TOC. Page 59 (OLD) 6 (NEW): Rewrote dwg. headers. Page 6 OLD) 64 New: Added TD, ; DCC; TB35, 36 description & p/ns. rewrote footnotes, deleted CS, p/ns. Page 6 (OLD): Deleted pg. (T Trans. only used on RCS units when Code = *A.) Repaginated form & updated the TOC. Page 68 (OLD) 70 (NEW): Deleted TD, info. Moved to pg. 6. Page 70 (OLD) 7 (NEW): Added MTIII Remote Keypad & Remote Interface p/ns. Page 7, 74 (OLD) 73, 76 (NEW): Added SHS p/ns. Updated/corrected R63 p/ns. Page 73 (OLD) 75 (NEW): Corrected SPS, p/n from to Added RHB, from (OLD) pg. 6. Added MTIII Remote Keypad & Remote Interface p/ns. Added Transducer Snubber p/n. Page 76, 99 (OLD): Deleted pg. Repaginated the form & updated the TOC. Page 95, 96 (OLD) 96, 97 (NEW): Updated/corrected Cond. Fan component p/ns. Page 00: Updated T trans. & components p/ns. Page 3 (NEW): Added pg. for IE. Repaginated form & updated the TOC. Page 4, 5 (OLD) 5, 6 (NEW): Added 06D components. Updated HGBP/Liquid Line p/ns & rewrote footnotes. Page 6 (OLD) 7 (NEW): Rewrote pg. header coding. Deleted Interface Board p/n.; moved p/n to Controls section. AO 08/7 Page 5, 6: Added Liquid Line Check Vlv. p/n. Page 7: Added additional Ref # 00 p/n, updated the Sensor p/n, corrected Check Vlv. p/ns & deleted footnote #. AP 09/7 Page 7: Misc. code updates. Page 43, 67: Rewrote Notes. Page 64: Added /7 & Later PVM components. Page 79: Corrected PVM qty. Page 89-97: Rewrote pg. header. Page 0: Added /7 & Later PVM components. Added footnote # 3. AQ 0/8 Page 49: Updated CC Heater Ref # 45. Updated Cmpr. dwg. Page Updated Cmpr. dwg. Page 7, 75: Deleted OBS Display. Combined with Remote Keypad AR 05/8 Page 9, 5: Misc. updates. Page 6: Rewrote footnotes. Page 4: Rewrote Notes. Page 79, 0: Corrected Code 7 coding. Page 3: Rewrote Notes & updated the dwg. Rewrote pg. header. Page 5 (NEW): Added pg. for additional dwgs. Repaginated form & updated the TOC. Page 5, 6 (OLD) 6, 7 (NEW): Updated/reorganized/corrected tables. Rewrote pg. header. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

6 Nomenclature Unit Model and Serial Number Unit Model Number R P S 050 D A Nominal Capacity (Tons) Ex. 050= 50 Tons Zone S, T= Singlezone Unit Unit Configuration P= Heating, mechanical cooling D= Heating, mechanical cooling, DrawThru F= Heating, future mechanical cooling C= Condensing section only Roofpak: R= Roofpak Applied Rooftop Design Vintage Heating Medium A= Natural Gas E= Electric S= Steam W= Hot Water Y= None (cooling only) Serial Number Plant Identification Abbreviation FBO= Faribault, MN U= Unit Year of Manufacture 09= 009, 0= 00, = 0, = 0, etc. FBO U Month of Manufacture 0= Jan. 04= Apr. 0= Feb. 05= May 03= Mar. 06= Jun. Serial Number (build sequence) 07= July 08= Aug. 09= Sept. 0= Oct. = Nov. = Dec. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

7 Nomenclature Unit Code Index RPS 050D S W Y EY D 7 AL P LE S 3 CD S0 BY AE 40B JEY Code C Y AB Y CYYS 4Z083D YYYYYY YYYYYY 30A LEY 50A WE3E CYYS 4Z083D YYYYYY Y Y BY Y 4 MS R Y D YYAA General Options Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier), 58 (Mid 0 & Later) Auxiliary Controls/Remote Sensors Unit Model Codes that Pertain:, 3, 6, 7, 8 Sections A, A Return/Outside Air/Heat Recovery Options Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier); 4, 58 (Mid 0 & Later) Sections B, C, D, E DrawThru Cooling Sections Section B- Filter Section Unit Model Codes that Pertain: 5, 33 (Mid 0 & Later), 50 (Mid 0 & Later) Section C- DrawThru Blank Access Unit Model Codes that Pertain: 4, 5, 6 Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 03, 7, 8 Section E- Spacer Section (RPS, RFS) Unit Model Codes that Pertain: 04, 30 Section E- DrawThru Heating Section (RDT) Unit Model Codes that Pertain: 30 Section F- Supply Fan Options Unit Model Codes that Pertain: 3, 3, 59 (Mid 0 & Later), 08, 4, 5, 40, 49 Sections G, H, I BlowThru Options Section G= BlowThru Heat/Blank Unit Model Codes that Pertain: 04, 34 Section H= BlowThru Blank Access Unit Model Codes that Pertain: 34 Section I- BlowThru Cooling Sections Unit Model Codes that Pertain: 03, 35, 36 Section J- Final Filter Section Unit Model Codes that Pertain: 39 Section K- Discharge Plenum Section Unit Model Codes that Pertain: 40 Section L- Out-of-Airstream Blank Access Section Unit Model Codes that Pertain: 4 Section M- Condenser Section Unit Model Codes that Pertain: 09,, 43, 44, 47, 54, 68 Section N- Main Control Panel Unit Model Codes that Pertain: 04, 08, 09,,, 4, 5, 7, 8, 3 (Mid 0 & Later), 68 Section O- Refrigeration Tubing Unit Model Codes that Pertain: 03, 45, 46, 48, 54 (Mid 0 & Later), 68 An "X" located in ANY position in a code string (ESPECIALLY Code 50 for units built mid 0 & earlier OR Code 60 for units built 0 & Later) indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). In mid 0 the code structure was changed from a 54 code index to a longer more detailed format. A sample 54 Code version is shown above. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

8 Nomenclature Unit Code Index, Continued Code 03= Cooling Coil S= Small L= Large Y= None Code 04= Heat Type A= Natural Gas S= Steam B= Propane W= Hot Water E= Electric Y= None Code 05= Unit Split F= Fan/Heat Y= None Code 06= Insulation and Liners =, 3/4# with liners on doors = ½, ½# with solid liners on doors & ceilings 3= ½, ½# with perforated liners in plenums, solid elsewhere 4= ½, ½# with solid liners on doors, ceilings and floors 5= ½, ½# with perforated liners in plenums, solid elsewhere (including floors) 6= ½, ½# with SS Solid Liners on doors, ceilings and floors Code 07= Approval Agency Listing CC, CD, CY= ETL Canada EM, EU, EY, YU= ETL/MEA- USA YY= None Code 08= Main Control Box Location D= Discharge Plenum (RPS, RFS) OR Standard (RCS) F= Supply Fan Section (RDT) Code 09= Unit Voltage = 08/60/3 9= 30/60/3 7= 460/60/3 37= 575/60/3 Code 0= Starting Option AL= Across- The- Line Code = Field Power Connection and Disconnect P= Single Power Block: Complete Unit Q= Two Power Blocks: EH/Balance of Unit R= Two Power Blocks: Fans & Controls/Balance of Unit A= One, thru-the-door Disconnect: Complete Unit C= Two, thru-the-door Disconnects: SAF&RAF&CB/Balance of Unit B= Two, thru-the-door Disconnects: EHB/Balance of Unit D= Three thru-the-door Disc.: EH/SAF&RAF&CB/Balance of Unit Code = Temperature Controls MicroTech III Digit : Communication Type L= LonWorks B= BACNet w/mstp E= BACNet w/ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit : Control Type E= Discharge Air w/ Static Pressure Control F= Space OR Zone Ctl. W= Discharge Air w/ Space Control No Controls YM= No Temperature Controls w/floating point control YC= No Temp. Ctls. w/6-9 volt DC modulating gas heat Actuator YA, A, A= RCS Standalone unit codes (see RPL form ) Code 3= Air Flow Controls Y= None = Duct Sensor = Duct Sensors 3= Duct and Space Sensor 4= Space Sensor Code 4= Inverters Y= None Separate Section = SA Fan only w/ Bypass = SA & RA Fans w/ Bypass 4= RA only w/ Bypass No Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan only no Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan only no Bypass Code 5= Inverter Brand Y= None A= ABB Inverter G= Graham Inverter Q= Schneider Inverter R= Reliance Inverter S, B= Daikin Applied Inverter F= Field Installed Inverter controlled by MicroTech Code 6= Smoke Detectors Y= None = Return Air Fan Section = Supply Air Fan Section 3= (RAF) + (SAF) Code 7= Misc. Aux. Controls C G Y= None F= Freezestat (Steam OR HW Heat only) P= Phase Failure G= Ground Fault Protection L= Line Reactors (Inverter w/ separate section only) A= Freezestat & Phase Failure (Steam OR HW Heat only) B= Freezestat & Ground Fault (Steam OR HW Heat only) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam OR HW Heat only) E= Freezestat & Line Reactors (ST/HW Heat & Inverter w/separate section only) H= Phase Failure & Line Reactors (Inverter w/ separate section only) J= Freezestat, P.F. & Line Reactors (ST/HW Heat & Inverter w/separate section only) K= Ground Fault, Phase Failure & Line Reactors (Inverter w/ separate section only) = UV Lights = UV Lights + F 3= UV Lights + P 4= UV Lights + L 5= UV Lights + A 6= UV Lights + E 7= UV Lights + H 8= UV Lights + J C= Differential Enthalpy Y= None (includes mechanical enthalpy) Code 8= Misc. Controls/ Unit Length A, S, Y = None ( = Air Handler Length [in.]) K, R = Remote Keypad ( = Air Handler Length [in.]) U = Unit Powered Receptacle ( = Air Handler Length [in.]) V = K + U ( = Air Handler Length [in.]) Code 9= Return Air Plenum YY= No section BY= Bottom Return BB= Bottom Return w/burglar Bars BE= Bottom Return w/isolation Damper HY= Back Return LY= Left Return SY= Side Return Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

9 Code 0= Outdoor Air Options YY= None AE= 00% Outside air Damper w/ Hood & Actuator AY= 00% Outside air damper w/ Hood w/o Actuator BE= 0-30% Outdoor air section w/ Actuator BY= 0-30% Outdoor air section w/o Actuator DE= 0-00% Econ. w/ barometric exhaust Damper w/ Act. DY= 0-00% Econ. w/ barometric exhaust Damper w/o Act. EE= 0-00% Econ. w/ power closure exhaust Damper w/ Act. EY= 0-00% Econ. w/ power closure exhaust Damper w/o Act. HE= 0-00% Econ. w/ prop exhaust Damper w/ Act. HY= 0-00% Econ. w/ prop exhaust Damper w/o Act. FE= same as DE + Design Flow FY= same as DY + Design Flow GE= same as EE + Design Flow GY= same as EY + Design Flow JE= same as HE + Design Flow JY= same as HY + Design Flow KE= same as DE + Ebtron Sensor KY= same as DY + Ebtron Sensor LE= same as EE + Ebtron Sensor LY= same as EY + Ebtron Sensor ME= same as HE + Ebtron Sensor MY= same as HY + Ebtron Sensor 3E= Energy Recovery Economizer, Low CFM- 6 wheel 4E= Energy Recovery Economizer, Low CFM- wheel 5E= Energy Recovery Economizer, High CFM- 6 wheel 6E= Energy Recovery Economizer, High CFM- wheel Code = Return Air Fan YYYY= No Return Air Fan 40B()= 40 Airfoil Single Width ()= Isolator type: = Rubber-in-Shear (RIS) = Spring 3= Spring w/ seismic restraints Code = Return Air Fan Motor YYY= No Return Fan J E Y Y= None S= Shaft Ground Kit E= High Eff. ODP motor H= High Eff. Totally-Enclosed J= Premium Eff. ODP K= Premium Eff. Totally-Enclosed G=.0 HP L= 0.0 HP Q= 30.0 HP H= 3.0 HP M= 5.0 HP J= 5.0 HP N= 0.0 HP K= 7.5 HP P= 5.0 HP (prop exhaust option is always J [5.0 HP]) Code 3= Return Air Fan Drive Selection (Mid 0 & Earlier RPS, RFS, RDT ALL) YYYY= No Return Air Fan A Required RPM Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Nomenclature Unit Code Index, Continued Code 3= Miscellaneous Electrical Options (Mid 0 & Later RPS, RFS, RCS ALL) Digit : UV Lights Y= None Digit : Plenum/Vestibule Lights Y= None Digit 3: SpeedTrol, Energy Recovery, HGRH Inverter Y= None A= ABB B= Daikin Applied Q= Schneider Digit 4: 5V Service Outlet Y= Field Supplied 5V Power, Outlet by Factory F= Factory supplied Line Voltage & Outlet Digit 5: Intelligent Equipment (IE) Y= None A= Intelligent Equipment L= ie Express Code 4= Exhaust Fans OR Frost Protection Y= None = Prop Exhaust Fan w/ Hood = Prop Exhaust Fans w/ Hood F= Heat Recovery Frost Protection Inverter Code 5= DrawThru Filter Section Digit : Section Type Y= No section A= Angular (4 Section) D= Angular with low CFM Blender- 48/4 section E= Angular with high CFM Blender- 48/4 section F= Flat (4 Section) G= Flat with low CFM Blender- 48/4 section (RPS, RFS Mid 0 & Earlier, RDT ALL) G= 4 Angular- 4 section (RPS, RFS Mid 0 & Later) H= Flat with high CFM Blender- 48/4 section L= Large Staggered- 48/4 section S= Staggered- 48 section T= Staggered with low CFM Blender- 48/48 section V= Staggered with high CFM Blender- 48/48 section B, D= Blank 4 section C, E= Blank 48 section Digit : Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/intersept H= Cartridge 85% Efficient w/ Intersept (RPS, RFS Mid 0 & Earlier, RDT ALL) H= Throwaway 85% Efficient (RPS, RFS Mid 0 & Later) D= Cartridge 65% Efficient E= Cartridge 95% Efficient G= Cartridge 95% Efficient w/intersept Code 6= Blank DrawThru Section Y= No section E= Blank 4 Section F, S= Blank 48 Section Code 7= DrawThru Drain Pan/Cooling Coil Section Digits - 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only (48 section) GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY only) Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

10 Nomenclature Unit Code Index, Continued Code 8= DrawThru Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D D= Lanced Aluminum C= Hi-F Copper w/ SS casing J= Hi-F Aluminum 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 9= DrawThru Heating Coil YYYYYY= No Heating Coil Code 30= DrawThru Heating Section (RDT only) OR Blank Spacer Section (RPS only) YYYYYY= No Heating Section EEEEEE= Blank 4 Section BBBBBB, FFFFFF= Blank 48 Section W J 3 E E= Electric Actuator Y= Less Actuator = Way Steam Valve Y= No Valve 3= 3 Way HW Valve E= ¼ Valve Pkg. H= ½ Valve Pkg. F= ½ Valve Pkg. J= 3.0 Valve Pkg. G=.0 Valve Pkg. Y= No Valve Pkg. S= 5JA060H (6FPI, Row 5J Steam Coil) S= 5JA0H (FPI, Row 5J Steam Coil) S3= 5JA060C (6FPI, Row 5J Steam Coil) S4= 5JA0C (FPI, Row 5J Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5WS HW Coil) E00 Y Always Y = Stage = Stages 4= 4 Stages 6= 6 Stages E00= 0 KW Heater E00= 00 KW Heater E040= 40 KW Heater E40= 40 KW Heater E060= 60 KW Heater E080= 80 KW Heater E00= 00 KW Heater E0= 0 KW Heater E60= 60 KW Heater Code 3= Supply Air Fan 7A()= 7 Airfoil Double Width 7F()= 7 Forward Curved, LP 7M()= 7 Forward Curved, MP 30A()= 30 Airfoil Double Width 30M()= 30 Forward Curved, MP 33A()= 33 Airfoil Double Width 33F()= 33 Forward Curved, LP 33M()= 33 Forward Curved, MP 40B()= 40 Airfoil Single Width (RDT only) 44B()= 44 Airfoil Single Width (RDT only) ()= Fan Isolators = Rubber-in-Shear (RIS) = Spring 3= Spring w/seismic Snubbers Code 3= Supply Air Fan Motor K E Y Y= None S= Shaft Ground Kit E= High Eff. ODP motor H= High Eff. Totally-Enclosed J= Premium Eff. ODP Motor K= Premium Eff. Totally-Enclosed H= 3.0 HP M= 5.0 HP R= 40.0 HP J= 5.0 HP N= 0.0 HP S= 50.0 HP K= 7.5 HP P= 5.0 HP L= 0.0 HP Q= 30.0 HP Code 33= Supply Air Fan Drive Selection (Mid 0 & Earlier RPS, RFS, RCS, RDT ALL) YYYY= None (RCS) A Required RPM Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 33= Miscellaneous Mechanical Options (Mid 0 & Later) Digit : Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DT & BT sections Digit : California Title 4 Y= None F= Economizer w/ Fault Detection/Diagnosis (FDD) Digit 3: Ebtron Air Flow Y= None S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold) Digit 4: Heating Coil Options Y= None E= Electrofin Coating Digit 5: Cooling Coil Options Y= None E= Electrofin Coating Code 34= BlowThru Heat Section (RPS, RFS only) YYYYYY= No section, cooling only BBBBBB= Blank 48 section, no heat, cooling only Gas Heat Breakdown: 00 S S C A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position E= Modulating Burner R= Modulating Burner/with H.P. Regulator Range= -3 psi S= Modulating Burner/with H.P. Regulator Range= 5-0 psi H= Hi Turn Down Burner 0: T= Hi Turn Down Burner 0:/with H.P. Regulator Range= -3 psi U= Hi Turn Down Burner 0:/with H.P. Regulator Range= 5-0 psi S= Stainless Steel Heat Exchanger MBH (in 0 s) ex. 00= 00 MBH [00,05,03,040,050,064,065,079,080,00] Hydronic Heat Breakdown: W J 3 E E= Electric Actuator Y= Less Actuator = Way Steam Valve Y= No Valve 3= 3 Way HW Valve E= ¼ Valve Pkg. H= ½ Valve Pkg. F= ½ Valve Pkg. J= 3.0 Valve Pkg. G=.0 Valve Pkg. Y= No Valve Pkg. S= 5JA060H (6FPI, Row 5J Steam Coil) S= 5JA0H (FPI, Row 5J Steam Coil) S3= 5JA060C (6FPI, Row 5J Steam Coil) S4= 5JA0C (FPI, Row 5J Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5WS HW Coil) Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

11 Code 34= BlowThru Heat Section, Continued Electric Heat Breakdown: E00 Y Always Y = Stage = Stages 4= 4 Stages 6= 6 Stages E00= 0 KW Heater E0= 0 KW Heater E040= 40 KW Heater E60= 60 KW Heater E060= 60 KW Heater E00= 00 KW Heater E080= 80 KW Heater E40= 40 KW Heater E00= 00 KW Heater Code 35= BlowThru Coil Section/Drain Pan (RPS, RFS only) YYYY= No section Digits - 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only- 48 section GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits - 3= DYY) T= Wide painted galvanized steel Drain Pan (Digits - 3= DYY) Code 36= BlowThru Cooling Coil (RPS, RFS only) YYYYYY= No Cooling Coil 4Z 08 3 D D= Lanced Aluminum C= Copper Fin 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch = Fins-per-inch 0= 0 Fins-per-inch 4= 4 Fins-per-inch 4Z= Type 4EZ Code 37= N/A to RPS/RDT/RFS/RCS- Always YYYYYY Code 38= BlowThru Blank Access Section (Mid 0 & Earlier) Y= No section B= Blank Section after Heat Section- 48 section Code 38= Attenuator Section (Mid 0 & Later) Y= No section G= With 36 Std. Straight Attenuator K= With 36 Std. Straight Attenuator w/ Tedlar Coating H= With 60 Std. Straight Attenuator L= With 60 Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating F= Blank 48 Section E= Blank 4 Section Code 39= Final Filter Section Y= No section A= Flat filter section, 95% cartridge, 4/4 section J= Flat filter section, 95% cartridge, 4 section B= Staggered filter section, 95% cartridge, 4/48 section K= Staggered filter section, 95% cartridge, 48 section E= Flat filter section, 95% cartridge w/ Intersept, 4/4 section L= Flat filter section, 95% cartridge w/ Intersept, 4 section F= Staggered filter section, 95% cartridge w/ Intersept, 4/48 section M= Staggered filter section, 95% cartridge w/ Intersept, 48 section G= Flat filter section, 95% HEPA cartridge, 4/48 section N= Flat filter section, 95% HEPA cartridge, 48 section H= Flat filter section, 95% cartridge, 48/48 section C, Q= Blank- 4/4 section D, R= Blank- 4/48 section S= Blank- 4 section T= Blank- 48 section Nomenclature Unit Code Index, Continued Code 40= Discharge Plenum BY= Bottom Discharge BB= Bottom Discharge w/ Burglar Bars BE= Bottom Discharge w/ Discharge Damper FY= Front Discharge (RFS) LY= Left Side Opposite Side RY= Right Side Drive Side SY= LH Side Discharge HY= LH Side Discharge (RDT) GY= Bottom Discharge (RDT) GB= Bottom Discharge w/ Burglar Bars (RDT) Code 4= Out-of-Airstream Blank Access Section Y= None = 48/4 Blank Section only- out of airstream with light = 48 Blank Section only- out of airstream with light Code 4= Compressor Capacity Control 4= 4 steps ( ) 6= 6 steps ( ) Code 43= Condenser Options YY= None (RFS) Digit : Air Coil M= 5mm Micro Channel Coil P= 5mm Electrofin Coated Micro Channel Coil T= 3mm Micro Channel Coil U= mm Electrofin Coated Micro Channel Coil Y= None Digit : Condenser Options G= Coil Guards, Steel S= Seal Tite Conduits B= G + S Y= None Code 44= Compressor Type R= Standard Scroll, R40A D= Digital Scroll, R40A Code 45= Compressor Isolation = Resilient Rubber-in-Shear Y= None (RFS) Code 46= Piping Options = Hot Gas Bypass, circuit # only = Hot Gas Bypass, cir. # & 3= Replaceable Filter Drier Core 4= + 3 5= + 3 Y= None Code 47= Low Ambient Operation = FanTrol Standard Fans = SpeedTrol Standard Fans 3= Quiet Fan + FanTrol 4= Quiet Fan + SpeedTrol Code 48= IBC Seismic Construction / Hot Gas Reheat Y= None A= ASCE 7-0 Wind Certification H= Modulating Hot Gas Reheat I= Seismic Construction K= Modulating Hot Gas Reheat and Seismic Construction J= IBC Seismic Construction- Category E/F Code 49= Fan Section Options A= SA Fan Belt Guard E= SA & RA Fan Section Light B= SA Fan Section Light F= D + E C= A + B Y= None D= SA & RA Fan Belt Guard Code 50= Miscellaneous (Mid 0 & Earlier) YY= None XX= Special Note that there are some Digital Scroll Compressor units built as SPECIALS (Code 44= R AND Code 60= XX with Digital Scroll compressors listed as a special feature). Refer to the Condenser Section Notes for more information on Digital Scroll Compressor units. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

12 Code 50= Blender Section (Mid 0 & Later) Y= None L= Low CFM Blender, 48 Section H= High CFM Blender, 48 Section E= Blank 4 Section F= Blank 48 Section Code 5= Packaging (Mid 0 & Earlier) = Steel Skid = Consolidated Ship Code 5= Draw=Thru Pre-Heat Section (Mid 0 & Later) YYYYY= None EEEEEE= Blank 4 Section FFFFFF= Blank 48 Section W E 3 E Y= No Actuator E= Electric Actuator Y= No Valve = - Way Valve (ST) 3= 3- Way Valve (HW) Y= No Valve E=.5 Valve J= 3.00 Valve F=.50 Valve G=.00 Valve H=.50 Valve = 9 FPI Row (HW) OR 6 FPI Row (ST) = FPI Row (ST) 3= 06 FPI Row (ST) 4= FPI Row (ST) = 9 FPI Row (HW) W= Hot Water Heat (HW) S= Steam Heat (ST) Code 5= Parts Warranty (Mid 0 & Earlier) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 5= Drain Pan/Humidifier Section (Mid 0 & Later) YY= None DH= Humidifier w/ stainless steel Drain Pan 48 section DY= Stainless steel Drain Pan only, 48 section EE= Blank 4 Section FF= Blank 48 Section Code 53= Compressor Warranty (Mid 0 & Earlier) Y= None (RFS) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special Code 53= Custom Specifications (Mid 0 & Later) YY= None RR= B vintage replacement unit Code 54= Heat Exchanger Warranty (Mid 0 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 54= Hot Gas/Liquid Subcool Reheat (Mid 0 & Later) YY= None BM= BlowThru Modulating Hot Gas Cir. # (includes SpeedTrol) ML= Modulating Liquid Subcool Reheat Circuits # & BL= BlowThru Modulating, Hot Gas Circuit #, AND Modulating Liquid Subcool Reheat Circuits # & Nomenclature Unit Code Index, Continued Code 55= Ultra High Efficiency Units YY= None HE= Ultra High Efficiency Unit (05D, 063D, 079D) Code 56= Chicago Code/Refrigeration Service Valves YY= None CC= Chicago Code YV= Refrigeration Service Valves CV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS/RDT/RFS/RCS- Always YY Code 58= Return Air Fan Drive Selection A Service Factor/Pitch Type Required RPM A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 59= Supply Air Fan Drive Selection A Service Factor/Pitch Type Required RPM A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 60= Misc. Specials YY= None XX= Special Code 6= Packaging/ASHRAE Certification = Steel Skid = Consolidated Ship 3= Steel Skid w/ ASHRAE Certification 4= Consolidated Ship w/ ASHRAE Certification Code 6= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 63= Compressor Warranty Y= None (RFS units only) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special Code 64= Heat Exchanger Warranty Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 65= Unit Family 047C= 045D- 075D 077C= 079D Code 66= Drain Connection Y= None L= Left Side R= Right Side (drive side) Code 67= ASHRAE Certification Y= None B= AHRI Certified C= AHRI Certified Code 68= Short Circuit Current Rating YY= None 0= 0 SCCR = SCCR 65= 65 SCCR Code 69-7 N/A to RPS/RDT/RFS/RCS- Always YYYYYYYY Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

13 Nomenclature Unit Section Layout Examples A= Return Air/Outside Air/ Heat Recovery/Prop Exhaust Section B, C, D, E= DrawThru Section F= Supply Fan Section G, H, I= BlowThru Section J= Final Filter K= Discharge Plenum L= Out-of Air- Stream Blank Access M= Condenser Section A B C D F G H J K M RPS A B C D F G H J K M Prop Exhaust DrawThru Return Air Fan DrawThru A B C D F G H J K M A B C F G H I J K M Heat Recovery DrawThru Heat Recovery BlowThru RFS A B C D F G H J K RCS M Return Air Fan DrawThru RDT A B C D E F M A B C D E F M With Prop Exhaust With Return Air Fan The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

14 Nomenclature Control Locations RPS, RFS, RCS Supply Air Section RDT Prop Exhaust (not shown) Condenser Section Inverters, Line Reactors & Manual Bypass Electric Heat Control Panel N Main Control Panel FanTrol/ SpeedTrol Box Controls Locations Condenser Control Panel (RCS Only) Condenser Control Panel (RCS Only) The Unit Section Layout Diagrams shown above are to be used only for reference. Sections and component locations may vary depending on unit size, configuration, and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

15 Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT0, Actuator Motors, Exhaust Dampers Return Air Section ACT, 3 Actuator Motors, Enthalpy Wheel Bypass Damper Energy Recovery Section AS Airflow Switch, Burner Blower Gas Heat Box BM Burner Blower Motor Furnace Section C- C4 Power Factor Capacitors, Compressors Condenser Section C0 Power Factor Capacitor, Supply Fan Supply Air Section C0 Power Factor Capacitor, Return Fan Return Air Section CB0 Circuit Breaker, Supply Fan Main Control Box CB0 Circuit Breaker, Return/Exhaust Fan Main Control Box CB60 Circuit Breaker, Energy Recovery Wheel Main Control Box CDT Thermistor, Discharge Digital Compressor Condenser Section COMPR.- 4 Compressors Condenser Section DAT Discharge Air Temperature Sensor Discharge section DCC Digital Compressor Controller Main Control Box DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS Disconnect, Total Unit OR Condenser/Heat Main Control Box DS Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS4 Disconnect, Condenser (RCS only) RCS Control Box DS6 Disconnect, Factory Powered Outlet Condenser Section EAT Exhaust Air Temperature Sensor Energy Recovery Section EFT Entering Fan Air Temperature Sensor Supply Fan Section ERM, Energy Recovery Wheel Motors Energy Recovery Section EXPA, B, C Expansion Boards Main Control Box FA, B Fuses, Control Circuit Transformer, (T) Primary Main Control Box FC Fuse, Control Circuit Transformer, (T) Secondary Main Control Box F Fuse, Control Circuit Transformer, (T) Primary Main Control Box F3 Fuse, Burner Blower Motor Main Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section FA, B Fuses, Digital Compressor Transformers Main Control Box FB0 Fuseblock, Supply Air Fan Main/Cond. Control Box FB,,, Fuseblocks, SpeedTrol Main/Cond. Control Box FB0 Fuseblock, Return Air Fan Main/Cond. Control Box FB3-40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Box FB4-50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Box FB60 Fuseblock, Energy Recovery Wheel Main/Cond. Control Box FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FP, Frost Protection, Refrigeration Circuits Coil Section, Cool FS, Freezestat Controls Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Box GFR, Ground Fault Relays Main Control Box GFS, Ground Fault Sensors Main Control Box GFR4 Ground Fault Relay, Condenser Condenser Control Box GFS4 Ground Fault Sensor, Condenser Condenser Control Box Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

16 Electrical Legend Continued Schematic Sym. Description Location GRD Ground All Control Boxes GV Gas Valve, Pilot Furnace Section GV Gas Valve, Main/Safety Furnace Section GV3 Gas Valve, Redundant/Safety Furnace Section GV4-8 Gas Valves, Main, Hi-Turn Down Furnace Section HL- 0 High Limits, Power, Electric Heaters (Top Bank) Electric Heat Section HL- 0 High Limits, Power, Electric Heaters (Bottom Bank) Electric Heat Section HL High Limit, Gas Heat (Prefilters) Supply Air Section HL3 High Limit, Gas Heat (Final Filters) Final Filter Section HL3-40 High Limits, Control, Electric Heaters (Top Bank) Electric Heat Section HL4-50 High Limits, Control, Electric Heaters (Bottom Bank) Electric Heat Section HP- 6 High Pressure Controls, Refrigerant Compr./Press./Cond. Box HP5 High Pressure Control, Gas Furnace Section HS Heat Switch, Electric Shutdown Main Control Box HS3 Heat Switch, Electric Heat Deadfront Interlock Electric Heat Box HTR- 6 Crankcase Heaters On Compressors HUM Humidistat Sensor Energy Recovery Section IT Ignition Transformer Furnace Section LAT Temperature Sensor, Leaving Air Energy Recovery Section LP- 6 Low Pressure Controls, Refrigerant On Compr./Cond. Box LP5 Low Pressure Control, Gas Furnace Section LR0 Line Reactor, Supply Fan Inverter Bypass Box LR0 Line Reactor, Return/Exhaust Fan Inverter Bypass Box LR, Line Reactors, Condenser Fan SpeedTrol Pressure/Cond. Box LS, Limit Switches, Low/High Fire Furnace Section LT0 Light, Supply Fan Supply Air Section LT Light, Return Fan Return Air Section LT Light, Heat Section Heat Section LT3 Light, Filter Section Filter Section LT4 Light, Final Filter Section Final Filter Section LT5 Light, Discharge Section Discharge Section LT6 Light, Blow-through Coil Section BlowThru Coil Section LT7 Light, Evaporator Coil Section Evaporator Coil Section LT8 Light, Preheat Section Preheat Section LT9 Light, Blank Section Blank Section LT0 Light, Blank/Empty Section Blank/Empty Section LT Light, DrawThru Coil Section DrawThru Coil Section LT Light, Condenser Section Condenser Section M- 6 Contactors, Compressors Main/Cond. Control Box M0 Contactor, Supply Fan Main Control Box M- 8 Contactors, Condenser Fans, Circuit # Main/Cond. Control Box M0 Contactor, Return Fan Main Control Box M- 8 Contactors, Condenser Fans, Circuit # Main/Cond. Control Box M9 Contactor, Burner Motor Furnace Section M30 Contactor Reversing, Inverter Bypass, Supply Fan Inverter Bypass Box M3-39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Reversing, Inverter Bypass, Return Fan Inverter Bypass Box M4-50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M60, 6 Contactors, Energy Recovery Wheel Motor Main Control Box MCB Microtech III Control Board Main Control Box MJ Mechanical Jumpers All Control Boxes Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

17 Electrical Legend Continued Schematic Sym. Description Location MMP- 6 Manual Motor Protectors, Compressors Main/Cond. Control Box MMP0 Manual Motor Protector, Supply Fan Main Control Box MMP- 8 Manual Motor Protectors, Condenser Fans Ckt. Main/Cond. Control Box MMP0 Manual Motor Protector, Return fan Main Control Box MMP- 8 Manual Motor Protectors, Condenser Fans Ckt. Main/Cond. Control Box MMP30 Manual Motor Protector, Inverter Bypass Supply Fan Inverter Bypass Box MMP40 Manual Motor Protector, Inverter Bypass Return Fan Inverter Bypass Box MMP5-53 Manual Motor Protectors, Exhaust Fan(s) Prop Exhaust Box MMP60, 6 Manual Motor Protectors, Energy Recovery Wheel Main Control Box MP- 6 Motor Protectors, Compressors On Compressors OAE Enthalpy Control, Outside Air Economizer Section OAT Temperature Sensor, Outside Air Economizer Section OL6 Overload- Energy Recovery Wheel () Main/Cond. Control Box PB, Power Blocks, Power Distribution Main Control Box PB3 Power Block, Power Distribution, Electric Heat Electric Heat Section PB4 Power Block, Power Distribution, Condenser Cond. Control Box PB9, 0 Power Blocks, Supply Fan Junction Box, Split Unit PB, Power Blocks, Power Distribution Main Control Box PB9, 0 Power Blocks, Return/Exhaust Fan Junction Box, Split Unit PC5 Pressure Control, Clogged Filter Pre Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Section PC3, 3 Pressure Controls, FanTrol Pressure/Cond. Box PC9 Pressure Control, Coil Splitter Pressure/Cond. Box PT, Pressure Transducers, SpeedTrol Pressure/Cond. Box PVM, Phase Voltage Monitors Main Control Box PVM4 Phase Voltage Monitor, Condenser Condenser Control Box R- Relays, High Pressure Reset (RCS only) RCS Control Box R5-8 Relays, Safety (RCS only) RCS Control Box R3-36 Relays, Compressor Staging (RCS only) RCS Control Box R Relay, Cond. Fan SpeedTrol Inverter Enable Pressure/Cond. Box R- 4 Relays, FanTrol Condenser Fan Cycling Main/Cond. Control Box R7 Relay, Cond. Fan SpeedTrol Inverter Enable Pressure/Cond. Ctrl. Box R0 Relay, Gas/Steam/Hot Water Furn./Main Ctrl. Box R, Relays, Gas Heat, 0: High Turndown Furn./Main Ctrl. Box R3 Relay, Gas Heat Furnace Section R4 Relay, Gas Heat Alarm Main Control Box R5 Relay, Gas Heat, Start Supply Fan Inverter Main Control Box R6 Relay, Isolation/Exhaust Dampers Main Control Box R8 Relay, Isolation Damper Safety Main Control Box R45 Relay, UV Lights Main Control Box R70-90 Relays, Specials/Digital Compressor Main Control Box RAE Enthalpy Sensor, Return Air Return Air Section RAT Temperature Sensor, Return Air Return Air Section REC Receptacle, Main Box Main Control Box REC Receptacle, Condenser Box Cond. Control Box REC3 Receptacle, Field Power, 5VAC Discharge Bulkhead REC0-3 Receptacles, Cabinet Sections Cabinet Sections S Switch, System On/Off Main Control Box S Switch, System On/Off, RCS Unit Cond. Control Box S3 Switch, Furnace On/Off Furnace Section Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

18 Electrical Legend Continued Schematic Sym. Description Location S4 Switch, Inverter Bypass On/Off Main Control Box S40-45 Switches, Door Interlock, UV Lights Cabinet Sections SC Speed Control, Circuit # Cond. Bulkhead SC Speed Control, Circuit # Cond. Bulkhead SD Smoke Detector, Supply Air Discharge Section SD Smoke Detector, Return Air Return Air Section SHS Sensor, Space Humidity Return Section (Field inst.) SPS, Sensors, Static Pressure, Duct or Building Main Control Box SV, Solenoid Valves, Liquid/Drop Condenser Section SV7 Solenoid Valve, Digital Compressor Condenser Section T Transformer, Main Control, Line/5VAC Main Control Box T Transformer, Control Input, 5/4VAC Main Control Box T3 Transformer, Control Output, 5/4VAC Main Control Box T6 Transformer, Factory Powered outlet, Line/5VAC Condenser Section T Transformer, SpeedTrol, Line/40VAC Condenser Section T, 3 Transformers, Digital Compressors Main Control Box TB Terminal Block, Internal for Transformers Main Control Box TB Terminal Block, Field Main Control Box TB3 Terminal Block, Factory, 5/4VAC Main Control Box TB4 Terminal Block, Field, 5VAC Main Control Box TB5 Terminal Block, RCS Field, 5V Condenser Control Box TB6 Terminal Block, RCS Field Condenser Control Box TB7 Terminal Block, 5VAC Convenience Outlet Main Control Box TB8 Terminal Block, RCS, 5VAC Convenience Outlet Condenser Control Box TB Terminal Block, Heating Furn./Elect. Heat Ctrl. Box TB5-8 Terminal Blocks, Split Unit Junction Box Split Unit Junction Box TB35, 36 Terminal Blocks, Digital Compressor Main Control Box TC- 4 Temperature Controls, FanTrol Condenser Section TD, Time Delays, Compressor Lockout (RCS only) Condenser Control Box TD0 Time Delay, Return Air Fan Main Control Box TD9 Time Delay, Coil Splitter Main Control Box TR, Transducers, Pressure, SpeedTrol Main Control Box UV Ultra-Violet Light(s) Coil/Discharge Section VFD0 Adjustable Frequency Drive, Supply Fan DrawThru/Supply Section VFD, Adjustable Frequency Drives, Cond. Fan SpeedTrol Pressure/Cond. Ctrl. Box VFD0 Adjustable Frequency Drive, Return/Exhaust Fan Dr. Thru/Ret./Exh. Section VFD60 Adjustable Frequency Drive, Energy Recovery Wheel Energy Recovery Section VM Valve Motor #, Heating Furnace/Heating Section VM5 Valve Motor #5, Cooling Coil Section, Cooling VV Vent Valve, Gas Heat Furnace Section ZNT Sensor, Zone Temperature, Setback Field Installed Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

19 Section A- Outdoor/Return Air Section Notes Primary Codes that pertain: 9, 0,,, 3 (Mid 0 & Earlier), 58 (Mid 0 & Later) Additional Codes that pertain: 06, 09,, 4, 5, 6, 7, 3 (Mid 0 & Later), 4, 33, 48, 49 Codes 9 and 0 determine the base section. Code 9 is the Return Air Plenum, and determines if the unit has back/ horizontal return air, bottom return air, left side return air, OR side return air. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 0= B*, D*, E*, F*, G*, H*, J*) OR Mixing Box (Code 0= C*). The only case in which a Plenum is not required is when a 00% Outdoor Air Damper and Hood are ordered (Code 0= A*). For units with Heat/Energy Recovery (Code 0= 3*, 4*, 5*, 6*) see Section A. Codes,, 3 (Mid 0 & Earlier) AND/OR 58 (Mid 0 & Later) determine the Return Air Fan, Motor and drive. These codes only pertain to units with a 0-00% Economizer (Code 0= D*, E*, F*, G* H*, J*). The Return Air Fan section parts, the fans, and the motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Return Fan motors range from - 30 horsepower, and the Fan is a 40 single width Airfoil Wheel. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 09, unit voltage, is part of the Return Fan Motor part number identification. Code, the control system, comes into play when an Economizer is present. The Economizer is supplied with an Actuator on MicroTech equipped units, but MAY OR MAY NOT come with a factory supplied Actuator if the unit has controls by others (Code = YM, YC). Codes 4 & 5 determine if the unit has a Return Air Fan Inverter/AFD/VFD and if so where it is installed. If Code 4= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 4=, 4 there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller. Code 6 determines if a Smoke Detector is located in the Return Air Cabinet. If Code 6=, 3, a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/ HGRH inverter brand specified, and/or the presence of Intelligent Equipment. Code 4 determines if there are Prop Exhaust Fans present and if so, whether it is a -fan or -fan arrangement. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Code 33 also indicates if the unit is California Title 4 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Light, Switch and Receptacle (Code 49= B, E), Fan Belt Guards (Code 49= D) OR both (Code 49= F). Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

20 Section A- Outdoor/Return Air Section 00% Outside Air Damper with Hood Code 0= AE, AY AND Code 9= YY No Return Air Plenum 4 9 Air Flow Section B Ref. Part Actuator Qty. No. Description C0= AE C0= AY 4 Damper Assy- Complete Damper only Liner Panel- Hood Side Panel- Hood Side Panel- Hood Top Louver Channel- Support Channel- Support This Damper Assy. includes the Damper, Damper Linkage, and Actuator. For Damper Assy. components see the following two pages. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified. This Damper Assy. includes the Damper and Damper Linkage, but NO Actuator. For Damper Assy. components see the following two pages. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

21 Section A- Outdoor/Return Air Section 00% Outside Air Damper Detail w/ Act3 Code 0= AE, AY AND Code 9= YY Diagrams Motorized Linkage Detail: Code 0= AE Manual Linkage Detail: Code 0= AY Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

22 Section A- Outdoor/Return Air Section 00% Outside Air Damper Detail w/ ACT3 Code 0= AE, AY AND Code 9= YY Components Ref. Part Actuator Qty. No. Description C0= AE C0= AY 4 Shaft- Linkage Not Used 5 Shaft Assy Not Used Adapter Plate- Crank Arm Not Used 7 Shaft- Linkage Not Used Channel- Support Not Used Blade- Damper Grille Stop-Anti Rotate, Damper Support- Damper Motor Not Used Support- Damper Not Used Linkage Bar Drive Tab Not Used 0 Crank Arm- Damper Not Used Crank Arm- Adjustable Not Used Ball Joint- Damper Actuator- Motorized, 4V ACT Not Used 3 Bushing- Linkage Bar, Nylon Bushing- Damper Blade, Nylon Gasket- Vinyl Gasket- Vinyl Plug- Damper End Plug- Damper End Plug- Damper End Bearing- Flange Sleeve Not Used 40 Bearing- Sleeve Not Used Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

23 Section A- Outdoor/Return Air Section 0-30% Outside Air Section w/ ACT3 Code 0= BE, BY Diagrams Linkage Detail: w/ Actuator Code 0= BE 4/ & Earlier Linkage Detail: w/ Actuator Code 0= BE 5/ & Later Linkage Detail: Without Actuator Code 0= BY 3 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

24 Section A- Outdoor/Return Air Section 0-30% Outside Air Section w/ ACT3 Code 0= BE, BY Components Ref. Part Actuator Qty. No. Description C0= BE C0= BY Damper Assembly- Complete Damper only Blade- Damper Gasket- Vinyl Gasket- Vinyl Seal- End Grille Support- Motor 4/ & Earlier Not Used Support- Motor 5/ & Later Not Used Rod- Support Angle Not Used Bar- Linkage Shaft- Linkage Louver Plug- End Plug- End Bushing- Damper Blade Bushing- Linkage Bar, Nylon Ball Joint- Damper Not Used 35 Actuator- Motorized, 4V ACT Not Used 36 Crank Arm- Damper Not Used 47 Bushing- Actuator Not Used 48 Channel Retainer 4/ & Earlier Not Used Channel Retainer 5/ & Later Not Used Damper assy includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Damper assy includes the Damper, Damper Linkage, but NO Actuator. 3 Damper only, NO Actuator Linkage OR Actuator. 4 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

25 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units w/o Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, KE, KY AND Code = YYYY Back Return (Code 9= HY) shown. Air Flow Ref. Part Part Qty. No. Description Number Economizer Damper w/ Act.(Code 0= DE, EE, FE, GE, KE) w/o Act. (Code 0= DY, EY, FY, GY, KY) Exhaust Damper Assembly Powered (Code 0= EE, EY, GE, GY) Barometric (Code 0= DE, DY, FE, FY, KE, KY) Economizer detail two pages after next. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

26 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Exhaust Damper Units with 40 Return Air Fans Code 0= DE, DY, EE, EY, FE, FY, GE, GY Code = 40B, 40B, 40B3 60 Bottom Return (Code 9= BY) shown (See Return Fan Detail) Air Flow (See Return Fan Detail) Ref. Part Part Qty. No. Description Number Economizer Damper w/ Actuator Code 0= DE, EE, FE, GE w/o Actuator Code 0= DY, EY, FY, GY 60 Exhaust Damper Assy. Powered Code 0= EE, EY, GE, GY Barometric Code 0= DE, DY, FE, FY Belt Guard Code 49= D, F Belt Guard Code 49= D, F Gasket Gasket Economizer detail on page after next. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

27 Section A- Outdoor/Return Air Section 0-00% Economizer Section with Prop Exhaust Fan & Damper Code 0= HE, HY, JE, JY AND Code 4=, Section Assembly Detail fan arrangement shown (Code 4= ) 0 40 Fan Guard Ref. Part Part Qty. No. Description Number 40 Fan Assembly, Std. Motor, 08/30/ Code, 3= **Y 05660, Fan Assembly, Std. Motor, Code, 3= **Y 05660, Fan Assembly, Grounded Motor, 08/30/ Code, 3= **S , Fan Assembly, Grounded Motor, Code, 3= **S , 5 Fan Guard Panel- Weather Hood Hood- Prop Exhaust N/S Grille Only- Prop Exhaust Hood 80 3 N/S= Not Shown on diagram. See detail following Isolation Damper Detail. Quantity may be one (Code 4= ) OR two (Code 4= ). 3 Quantity is PER fan. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

28 Section A- Outdoor/Return Air Section 0-00% Economizer Damper Detail Code 0= D*, E*, F*, G* H*, J* Diagrams Linkage Detail: With Actuator (Code 0= *E) 3 Linkage Detail: Without Actuator (Code 0= *Y) Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

29 Section A- Outdoor/Return Air Section 0-00% Economizer Damper w/ ACT3 Code 0= D*, E*, F*, G* H*, J* Components Ref. Part Actuator Qty. No. Description C0= *E C0= *Y Damper Assy- Complete Damper Assembly Shaft Assembly Not Used 5 Shaft Assembly Not Used Plate- Crank Arm Not Used Shaft Assembly Not Used Shaft- Linkage Channel- Support Blade- Damper Stop/Anti-Rotate- Damper Channel- Support Not Used Bar- Linkage Drive Tab- Linkage Bar Crank Arm- Adjustable Not Used Ball Joint- Damper Actuator- 4V ACT Not Used 3 Bushing- Linkage Bar Bushing- Damper Blade Gasket- Vinyl Gasket- Vinyl End Plug- Damper End Plug- Damper End Plug- Damper Bushing- Actuator Not Used 3 Channel- Actuator Not Used N/S Gasket- Neoprene N/S= Not Shown on Diagram. Damper Assy. includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that the correct assembly can be identified. Damper Assy. includes the Damper and Damper Linkage, but NO Actuator. 3 Damper only, NO Actuator Linkage OR Actuator. 4 Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel. 5 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

30 Section A- Outdoor/Return Air Section California Title 4 Assembly Code 33 (Mid 0 & Later) = *F*** Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch Bracket, Mounting Switch Switch, Push Button SPDT Bushing, Conduit 3630 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 30

31 Section A- Outdoor/Return Air Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE ACT6 Actuator Detail Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized Motor Mount Assembly Blade Assembly- Return, Angle- Linkage Angle- Blade Shaft- Damper Blade Shaft- Linkage Bearing- Flange, Nylon Actuator- Motorized, 4V ACT Crank Arm- Damper Ball Joint Bearing- Sleeve Gasket- Vinyl Bracket- Support Retainer- Actuator Bearing- Sleeve Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

32 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Detail Code 0= HE, HY, JE, JY AND Code 4=, 40A 40 Fan Assembly Components Fan Arrangement Shown (Code 4= ) 54 5 B A 6C 6B 6D 6E 6F 6G 6H Lube Line Detail 53 Control Box (see following page 6I Voltage Ref. Sch. Part Part No. Sym. Description Number AFD0 Inverter see charts on following pages A Resistor- Inverter B Jumper- Inverter B Fan Prop C Fan Shaft D Bearing E Fan Sheave F Bushing- Fan Sheave G Belt H Motor Sheave I Motor Motor Tube- Plastic Coupling- Tube.5 x.5 FPT Fitting- Grease B Jumper- Inverter Fan Assembly, Std. Mtr. Code, 3= **Y Fan Assembly, Std. Mtr. Code, 3= **Y Fan Assembly, Grd. Mtr. Code, 3= **S Fan Assembly, Grd. Mtr. Code, 3= **S A Damper- Backdraft 3 Quantity= when Inverter model 3500 (Code 5= G) is used. Quantity shown is for fan (Code 4=). Quantities for fan units (Code 4= ): Ref. 5= 5 ; Ref. 53= 4; Ref. 54= 4. 3 Contact Daikin Applied. 4 Quantity is PER fan. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

33 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Detail Code 0= HE, HY, JE, JY AND Code 4=, Continued 03/3 & Earlier Inverter- Fan Units (Code 4= ) Voltage Code Inverter Model Part 5= Number A G R VTAC VTAC S MD MD V 30V Inverter- Fan Units (Code 4= ) Voltage Code Inverter Model Part 5= Number A G R VTAC VTAC S MD MD V 30V Prop Exhaust Fan Control Box OL5 M5 OL5 M5 0 Contactors & Overloads Detail Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload Overload Overload Overload M5, 5 Contactor Contactor NOTE: Quantities listed are for a Fan unit (Code 4= ). 08V 30V Fan Unit shown. 30 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 33

34 Section A- Outdoor/Return Air Section Prop Exhaust Fan & Damper Detail Code 0= HE, HY, JE, JY AND Code 4=, Continued 04/3 & Later Inverter- Fan Units (Code 4= ) Voltage Code Inverter Model Part 5= Number A B MD MD G Q MD MD R VTAC VTAC S MD MD V 30V Inverter- Fan Units (Code 4= ) Voltage Code Inverter Model Part 5= Number A B MD MD G Q MD MD R VTAC VTAC S MD MD V 30V Prop Exhaust Fan Control Box 0 30 OL5 OL5 M5 M5 Fan Unit shown 0 30 Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload Overload Overload Overload M5, 5 Contactor 5A Contactor 6A Contactor 9A Contactor 7A NOTE: Quantities listed are for a Fan unit (Code 4= ). 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 34

35 LH Louvered Door Assy Section Final Assembly Section A- Outdoor/Return Air Section Design Flow Code 0= FE, FY, GE, GY, JE, JY Louvered Door Assembly Detail RH Louvered Door Assy Design Flow Vane and Vane Bearings Detail Adjuster Control Assy Detail 30 Spring Detail Ref. Part Part Qty. No. Description Number Louver Panel Left Hand Door Louver Panel Right Hand Door Grille Gasket Gasket Potentiometer O-Ring, Potentiometer Panel- Vane Shaft- Upper Bearing- Lower Crank Arm Assy Left Hand Door Crank Arm Assy Right Hand Door Link Arm 0 Bearing Bearing Spring- Main.75 x Spring- Secondary.30 x N/S Leveling Kit- Design Flow Quantity is PER door. P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 35

36 Section A- Outdoor/Return Air Section 40 Return Air Fan (Code = 40B*) Ref. Part Part Qty. No. Description Number Motor see tables one & two pages after next Fan Housing Assy- Inlet Funnel Inlet Funnel Wheel- Air Foil Fan, SI/SW Mount- Motor Shaft.937 Diameter Coupling /8 MPT Coupling- Reducer /4 X /8 FPT Tubing- Plastic Grease Fitting /8 MPS Bearing- Ball.937 bore Key- Wheel / X 5 / Key- Fan Sheave / X 4 / Mounting type, fourth digit: = RIS, = Spring, 3= Spring w/ Seismic Snubbers. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 36

37 Section A- Outdoor/Return Air Section Return Air Fan Mounts (Code = 40B*) Rubber Mounts Rubber Mounts (Code = 40B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black , 30 Rubber Mount- Red Rubber Mount- Black Rubber Mount- Red Rubber Mount- Black Rubber Mount- Black All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or 6 63 or or 64 Mounting Diagram Spring Mounts 6 or 6 Seismic strap used only when Code = 40B Spring Mounts (Code = 40B) & Seismic Spring (40B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code = 40B Seismic Code = 40B Spring Mount- Yellow , 5 Spring Mount- Yellow Spring Mount- Green Spring Mount- Dark Brown , 5, 0, 5 Spring Mount- Dark Brown Spring Mount- Green Spring Mount- Red Spring Mount- Yellow Spring Mount- Blue Spring Mount- Dark Brown Spring Mount- Yellow Spring Mount- Yellow , 30 Spring Mount- Blue All Nut Spring Code = 40B Seismic Code = 40B All Nut All Screw Spring Code = 40B 0470 Seismic Code = 40B Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 37

38 Section A- Outdoor/Return Air Section Return Air Fan Motors Standard Motors: Code = **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Motor Code = Voltage C= *EY C= *JY C= *HY C= *KY Mount C09= G*Y 08/60/ H*Y 08/60/ J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ P*Y 08/60/ Q*Y 08/60/ C09= 9 G*Y 30/60/ H*Y 30/60/ J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ P*Y 30/60/ Q*Y 30/60/ C09= 7 G*Y 460/60/ H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ C09= 37 G*Y 575/60/ H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ Note that the Return Fan Motor Mounts listed are used ONLY in Heat Recovery units when Code = 40B* AND Code 0= 3*, 4*, 5*, 6*. See the 40 Return Fan Detail in Section A- Outdoor/Return Air w/ Heat Recovery Section. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 38

39 Section A- Outdoor/Return Air Section Return Air Fan Motors Shaft Grounded Motors: Code = **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C= **S Voltage C= *JS C= *KS C09= G*S 08/60/ N/A 3 H*S 08/60/ J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ P*S 08/60/ Q*S 08/60/ C09= 9 G*S 30/60/ H*S 30/60/ J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ P*S 30/60/ Q*S 30/60/ C09= 7 G*S 460/60/ H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ C09= 37 G*S 575/60/ H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ N/A= Not Available. For Return Fan Motor Mounts used in Heat Recovery units (when Code = 40B* AND Code 0= 3*, 4*, 5*, 6*) refer to the previous page. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 39

40 Section A- Outdoor/Return Air Section Section Mounted Controls OAE, RAE, LT, S, REC Bottom Return Shown Code 9= BY, BE Economizer Damper 40 4 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n & Mount Minor field modifications are required for proper installation & operation when changing to the newer design. Bottom Return Shown Code 9= BY, BE Economizer Damper OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE BOTH original controls are obsolete & no longer available. For the OAE Control use & Mount For the RAE Control use & Mount Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay (OAER), are required for proper installation & operation. RAT- Outdoor Air Temperature Sensor 7 Ref. Part Part Qty. No. Description Number 7 Sensor- RAT Return Air Opening 30 Return Air Opening SD- Return Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 30 Smoke Detector- SD Back Return Code 9= HY Bottom Return Code 9= BY, BE LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 40

41 Section A- Outdoor/Return Air w/ Heat Recovery Section Notes Primary Codes that pertain: 9, 0,,, 3 (Mid 0 & Earlier); 4, 58 (Mid 0 & Later) Additional Codes that pertain: 06, 09, 4, 5, 6, 7, 48, 49; 3, 33 (Mid 0 & Later) Codes 9 and 0 determine the base section. Code 9 is the Return Air Plenum; Code 0 determines the type of Outdoor Air/Heat Recovery control used. When Code 0= 3E, 5E the unit has a 6 Heat Recovery Wheel. If Code 0= 4E, 6E the unit has a Heat Recovery Wheel. Codes,, 3 (Mid 0 & Earlier), and 58 (Mid 0 & Later) determine the Return Air Fan, Fan Motor and drive selection. The fan section parts, the Fans, and the Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. The motors range from - 30 horsepower, and the Fan is a 40 Single width Airfoil Wheel. Code 4 determines if the Heat/Energy Recovery Wheel has a Frost Protection Inverter. Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 09, the voltage, is part of the Return Fan Motor part number identification. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4= 3, 5, 6, 7, 8, 9 the inverter(s) are installed in the Supply Air Section. If Code 4=,, 4 AND Code 6= S, there is a separate Inverter Section. If Code 4= Y, there are no inverters. Code 5 determines the Inverter Vendor. For inverter part numbers, refer to the Supply Air Section (Section F). Code 6 determines if a Smoke Detector is located in the Return Air Cabinet. If Code 6=, 3, a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 7= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/ HGRH inverter brand specified, and/or the presence of Intelligent Equipment. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for part numbers and descriptions. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 48 determines if the unit is equipped with IBC seismic construction. Code 49 determines if the Return Air Cabinet has a Belt Guard (Code 49= D), OR a Belt Guard and a Fan Section Light (Code 49= F). Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

42 Section A- Outdoor/Return Air w/ Heat Recovery Section Cabinet Gaskets, Doors, Hardware, Exhaust Hoods Code 0= 3E, 4E, 5E, 6E Cabinet Gaskets, Doors and Exhaust Hoods (LH components shown) Hood Exhaust Hood- See Detail to Left Ref. Part Part Qty. No. Description Number 44 Hinge Door Door- Exhaust Door- Exhaust Door Door Door Gasket- Vinyl Gasket- Vinyl Gasket- Vinyl Damper- Back Draft x Panel- Hood Panel- Hood RH Panel- Hood LH Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

43 Section A- Outdoor/Return Air w/ Heat Recovery Section Base Components, Hood, Dampers Outdoor Air Intake Hood Detail Code 0= 3E, 4E, 5E, 6E See Hood Detail to Left 60 Base Assembly A Ref. Part Part Qty. No. Description Number Fan Assembly Damper- OA Low Leak w/ Actuator ACT3 A Damper- RA Low Leak w/ Actuator ACT4 30 Channel- Fan Channel- Fan Panel- Outdoor Intake Hood, Top Panel- Outdoor Intake Hood, Side Panel- Outdoor Intake Hood, Side Louver- Outdoor Intake Hood Louver- Outdoor Intake Hood Louver- Outdoor Intake Hood Screen- Outdoor Intake Hood Wheel, Enthalpy- Heat Recovery 3 0 Filter Rack- Upper LH Filter Rack- Upper RH Filter Rack- Lower LH Filter Rack- Lower RH Filter- 30% 6 x 0 x Filter- 30% 6 x 5 x Stop- Filter Damper- L Bypass w/ Actuator ACT, 3 4 See detail on following page. See detail following Fan Mount detail. 3 See detail following L Bypass Damper detail. 4 See detail following Low Leak Damper detail. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 43

44 Section A- Outdoor/Return Air w/ Heat Recovery Section 40 Return Air Fan (/ & Earlier) 0A 0B 0C 7 Thrust Restraint Detail Ref. Part Part Qty. No. Description Number Motor 7 Gasket Fan Assembly A Fan Wheel B Bearing- Inlet Side N/S Bearing- Drive Side C Shaft 0088 Motor Mount 40 Angle- Thrust Restraint Spring Mount, Floor- Thrust Restraint Red N/S= Not Shown on diagram. See Return Air Fan Motor Tables. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 44

45 Section A- Outdoor/Return Air w/ Heat Recovery Section 40 Return Air Fan Mounts (/ & Earlier) Fan Mounting Locations 35B 35C 35A Top View 35D Rubber-In-Shear (Code = 40B) Mounting Detail 84 8 Fan 84 Channel 35A 35B 35C D 50 Ref. Motor Part Part Qty. No. HP Description Number 35A - 5 Vibration Mount Green Vibration Mount Gray B All Vibration Mount Green C - 0 Vibration Mount Red Vibration Mount Green D - 0 Vibration Mount Green Vibration Mount Gray Nut- Hex Nut- Hex Screw Screw Nut- Hex Washer Washer Support /mt Spring (Code = 40B) OR Spring w/ Seismic Snubber (Code = 40B3) Mounting Detail 84 Fan Channel A 35B 35C 35D Ref. Part Part Qty. No. Description Number 35A All Vibration Mount Yellow B, 3 Vibration Mount Green Vibration Mount Gray C - 5 Vibration Mount Green , 5 Vibration Mount Gray D - 5 Vibration Mount Gray Vibration Mount Yellow Mount- Seismic Nut- Hex Nut- Hex, Spring Code = 40B Nut- Hex, Seismic Code = 40B Screw- Cap Washer Seismic snubber parts only (Code = 40B3). Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 45

46 Section A- Outdoor/Return Air w/ Heat Recovery Section 40 Return Air Fan (/ & Later) Motor 490 Ref. Part Part Qty. No. Description Number 07 Inlet Funnel Bearing, Roller- Drive Side 3/ Bearing, Ball- Inlet Side 3/ Shaft, 3/ Key Fan Wheel Motor Mount See Return Air Fan Motor Section. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 46

47 Section A- Outdoor/Return Air w/ Heat Recovery Section 40 Return Air Fan Mounts (/ & Later) Rubber Mounts Rubber Mounts (Code = 40B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Rubber Mount- Red All Channel- Mount Support All Nut, Clinch All Screw, 3/8-6 x All Screw, 5/ All Nut- / All Washer- Plain, / All Screw, Cap Mounting Diagram Spring Mounts Seismic strap used only when Code = 40B Spring Mounts (Code = 40B) & Seismic Spring (40B3) Ref. Fan Motor Part Part Qty. No. HP Description Number 34-5 Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Dark Brown , 0 Spring Mount- Red Spring Mount- Tan Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Dark Brown All Mount Spring Code = 40B Seismic Code = 40B All Nut, Clinch All Screw, 3/8-6 x Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 47

48 Section A- Outdoor/Return Air w/ Heat Recovery Section Low Leak Damper Detail (Ref. #, A) with ACT3 (Outside Air) OR ACT4 (Return Air) MicroTech III Controls (Code = *E, *F, *W) ACT3 OR ACT4 Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator Complete Assy- Less Actuator Seal- End Stop- Damper End Plug Blade- Damper Actuator, 4V ACT3, End Plug End Plug Bushing- Linkage Bushing- Damper Blade Shaft- Drive N/S Gasket- Vinyl N/S Gasket- Vinyl N/S= Not Shown on diagram. NOTE- The drawing is a generic illustration of this damper type, and shows part location, but does not show the actual part quantities listed in the table. Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 48

49 Section A- Outdoor/Return Air w/ Heat Recovery Section Bypass L Type Damper Detail w/ ACT (Outside Air) OR ACT3 (Return Air) (Ref. # 30) MicroTech III Controls (Code = *E, *F, *W) Actuator Detail ACT OR ACT Ref. Part Part Qty. No. Description Number Complete Assembly w/ Actuator Complete Assembly w/o Actuator Blade- Damper Blade- Damper Linkage- Channel Gasket- Vinyl Gasket- Vinyl Gasket- Vinyl Plug, End- Damper Plug, End- Damper Stop- Damper Bushing- Damper Blade Bushing- Linkage Bar End Plug- Damper Lock Collar Bushing- Drive Shaft Actuator, 4V ACT, Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 49

50 Section A- Outdoor/Return Air w/ Heat Recovery Section Heat Recovery/Enthalpy Wheel Wheel, Motor, Drive Components, Seals Outdoor Air Out (Supply) Exhaust Air In (Return) Low Air Flow ERW (Code 0= 3E, 5E)- 6 Wheel Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 08/30/ Segmented Wheel Motor 08/30/ Sheave Bearing Shaft Belt N/S Inner Seal N/S Outer Seal N/S= Not Shown on diagram. Includes motor, shaft, belt etc. If a replacement wheel is required, it is suggested that this part number be used. The segmented wheel ships disassembled which allows for easier shipping and installation. High Air Flow ERW (Code 0= 4E, 6E)- Wheel Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 08/30/ Segmented Wheel Motor 08/30/ Sheave Bearing Shaft Belt N/S Inner Seal N/S Outer Seal Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 50

51 Section A- Outdoor/Return Air w/ Heat Recovery Section AFD60 Frost Protection Inverter (Code 4= F) Heat Wheel 3 Mid 0 & Earlier Voltage Ref. Sch. Part Part No. Sym. Description Number 3 VFD60 Inverter VFD60 Inverter VFD60 Inverter In Mid 0 the Unit Model Nomenclature was changed to code the different Inverter brands offered. Before this date ATV OR ATV drives (see note below) were standard. In 00 the original ATV Inverters were replaced with ATV Inverters as listed above. These Inverters are drop in replacements with the exception of the Remote Keypad and Communication Cards. If a Communication card OR Remote Keypad is required, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Note that since the original ATV drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV part fails, the entire drive must be replaced. 08V 30V Mid 0 & Later Voltage Ref. Sch. Part Part No. Sym. Description Number 3 Code 3= **A** 3 VFD60 Inverter Inverter Inverter Code 3= **B** 3 VFD60 Inverter Inverter Inverter Code 3= **Q** 3 VFD60 Inverter Inverter Inverter For the fusing for VFD60, refer to the "Heat/Energy Recovery Wheel Contactors, MMPs & Fusing 04/3 & Later" page in Section N. 4 The replacement VFD Keypad is p/n V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

52 Section A- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls OAE, RAE, RAT, EAT, LAT Bottom Return Shown Code 9= BY, BE Economizer Damper 40 4 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n & Mount Minor field modifications are required for proper installation & operation when changing to the newer design. Bottom Return Shown Code 9= BY, BE Economizer Damper 4 48 RA Opening Deck Panel 00 4 OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE BOTH original controls are obsolete & no longer available. For the OAE Control use & Mount For the RAE Control use & Mount Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay (OAER), are required for proper installation & operation. RAT- Outdoor Air Temperature Sensor Ref. Part Part Qty. No. Description Number 84 Support- RAT RA Sensor- RAT EAT- Outdoor Air Temperature Sensor Return Fan Ref. Part Part Qty. No. Description Number 4 Support- EAT RA Sensor- EAT LAT- Leaving Air Temperature Sensor Ref. Part Part Qty. No. Description Number 58 Support- LAT Sensor- LAT Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

53 Section A- Outdoor/Return Air w/ Heat Recovery Section Section Mounted Controls SD, HUM, LT, S, REC Heat Wheel RA Opening 30 7 SD- Return Air Smoke Detector Code 6=, 3 Ref. Part Part Qty. No. Description Number 7 Support- SD Smoke Detector- SD RA Opening RAT Deck Panel HUM- Humidistat (units with frost protection) Code 4= F Ref. Part Part Qty. No. Description Number 596 Support- HUM /6 & Earlier 0780 /7 & Later Humidistat- HUM /6 & Earlier /7 & Later This is the duct mounted Humidistat. If a unit has a wall mounted Humidistat use p/n LT- Return Fan Light/S- Return Fan Light Switch/REC- Return Fan Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 53

54 Section B- DrawThru Filter/Blank Section Notes Primary Codes that pertain: 5, 33 (Mid 0 & Later), 50 (Mid 0 & Later) Additional Codes that pertain: 06, 9, 0 Code 5 determines the section s characteristics. If the first digit of Code 5= A, G the Filters are in an angular rack, if the first digit = F the Filters are in a flat rack, or if the first digit = L, S the filters are in a staggered rack. If the second digit = B there are 30% eff. throwaway filters; if C there are 30% eff. throwaway filters with Antimicrobial Intersept; if H there are 85% throwaway filters. If the second digit = D there are 65% eff. filters, if E there are 95% eff. filters, and if G there are 95% eff. filters with Antimicrobial Intersept. If the second digit = Y there is no filter media specified. If Code 5 = BY, EY there is a Blank/Empty section. Code 5= D*, E*, G*, H*, T*, V* OR Code 50 [Mid 0 & Later]= L, H indicates the presence of an Air Blender. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter gauge. Even though the gauge may be located in several different places in the unit, the p/n is listed in this section for convenience. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank Access Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Codes 9 and 0 determine Return Air section characteristics which has an effect on the final assembly panels. Section Mounted Controls PC5, LT3, S3, REC3 Controls PC5 Ref. Part Part Qty. No. Description Number 65 Pressure Control- PC LT3- Filter Section Light/S3- Filter Section Light Switch/REC3- Filter Section Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 54

55 Section B- DrawThru Filter/Blank Section Filters Typical Angular Filter Section Shown Code 5= A* Ref. Part Code Part Qty. No. Description 5= Number Angular Filter Section (Code 5= A*, D*, E*) N/S Filter 30% Pleated, 6 x 5 x " MERV 8 *B % Pleated, 6 x 5 x " w/ Intersept MERV 8 *C % Disposable, 6 x 5 x MERV 3 *H N/S Filter 30% Pleated, 6 x 0 x MERV 8 *B % Disposable, 6 x 0 x w/ Intersept MERV 8 *C % Disposable, 6 x 0 x MERV 3 *H N/S Media Filler Piece ALL N/S Angle Assembly ALL Flat Filter Section (Code 5= F*, G*, H*) N/S Filter, Cartridge 65% Cartridge, 4 x 4 x " MERV *D % Cartridge, 4 x 4 x " MERV 4 *E % Cartridge, 4 x 4 x " w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x " MERV *D % Cartridge, x 4 x " MERV 4 *E % Cartridge, x 4 x " w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL N/S Pre Filter, x 4 x ALL Staggered Filter Section (Code 5= L*, S*, T*, V*) 65% Cartridge, 4 x 4 x MERV *D % Cartridge, 4 x 4 x MERV 4 *E % Cartridge, 4 x 4 x w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D % Cartridge, x 4 x MERV 4 *E % Cartridge, x 4 x w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL N/S Pre Filter, x 4 x ALL Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. Optional. Angle is mounted on leaving air side. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 55

56 Section B- DrawThru Filter/Blank Section Air Blender Section Components, & Magnehelic/Differential Pressure Gauge Air Blender Section Components (Code 5= D*, E*, G*, H*, T*, V*) OR (Code 50 [Mid 0 & Later]= L, H) 75 Ref. Part Code 50= Part Qty. No. Description Number 65 Panel- Access All Air Blender Low CFM L High CFM H Plate- Econo. Linkage Access All Magnehelic/Differential Pressure Gauge (Code 33= A****, B****, C**** [Mid 0 & Later]) 3396 Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0-3 WC Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 56

57 Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes Primary Codes that pertain: 6, 4, 5 Additional Codes that pertain: 06 Code 6 determines if a section is installed and if so, the size of the section. If Code 6= E there is a 4 Blank/ Empty section; if Code 6= F, S there is a blank 48 section; if Code 6= Y, there is no section. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4=,, 4 AND Code 6= S, there is a separate Inverter Section. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4= Y, there are no inverters. Code 5 identifies the inverter brand supplied. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the inverters are listed in the Supply Air Section (Section F). Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank/Empty Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Return Air Inverter (AFD0) Supply Air Inverter (AFD0) Section Mounted Controls LT, S, REC LT- DT Access Section Light/S- DT Access Section Light Switch/REC- DT Access Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 57

58 Section D- DrawThru Cooling Section Notes Primary Codes that pertain: 03, 7, 8 Additional Codes that pertain: 06 Code 03 determines the DX cooling coil size. If Code 03= S there is a small face area coil (4 section), and if Code 03= L it is a large face area coil (48 section). Code 7 determines if there is a Section D. If Code 7= YYYY, then there is no section (for RPS OR RFS units this indicates that the cooling coil is in the BlowThru position. RDT units always have a section D). If the first three digits of Code 7= DYY then the section contains only a drain pan in a 48 section. If the first three digits of Code 7= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 7= S, the Drain Pan is stainless steel, P, Y in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 7= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 7= L, T, then the first three digits of Code 7 must equal DYY. Code 8 will apply only if Code 7= CYYY OR CYYS, and determines the DrawThru Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. NOTE: The drawings and components listed in this section also apply to Section I BlowThru Cooling Section for RPS OR RFS units. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 58

59 Section D- DrawThru Cooling Section Evaporator Coils, Drain Pans, Gasketing, 4 Section, Small Face Coils- Code 03= S Small Face Area Coil 4 Section Code 03= S Ref. Part Part Qty. No. Description Number 3 Coil 0 Drain Pan, 3 Galv. C7= CYYY, CYYP Stainless C7= CYYS Pan- Auxiliary, Gasket Gasket Section, Large Face Coils- Code 03= L Unit Sizes only Large Face Area Coil 48 Section Code 03= L Ref. Part Part Qty. No. Description Number 3 Coil- Lower 4 Coil- Upper 0 Drain Pan, 3 Galv. C7= CYYY, CYYP Stainless C7= CYYS Drain Pan, 3 Galv. C7= CYYY, CYYP Stainless C7= CYYS Pan- Liner Pan- Auxiliary Gasket Gasket Gasket Contact Daikin Applied with unit GO and/or serial number so that the correct coil(s) can be identified. For Drain Pans and components when Code 7= GYY* AND/OR Code 7= ***L, ***T contact Daikin Applied with model and serial number information so that the required part(s) can be identified. 3 For BlowThru units (Code 35 AND Code 36 CANNOT be all Ys) substitute Code 35 for Code 7. BlowThru and DrawThru Cooling sections use the SAME parts, just the coding is different. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 59

60 Section E- Spacer Section (RPS, RFS) Notes Primary Codes that pertain: 30 Additional Codes that pertain: 06 For RPS, RFS units Code 30 is normally YYYYYY. If Code 6= EEEEEE there is a 4 Blank/Empty section; if Code 6= BBBBBB, FFFFFF then there is a 48 Blank/Empty section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48 Spacer Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Section Mounted Controls LT8, REC8, S8- Section Mounted Light LT8- Spacer Section Light/S8- Spacer Section Light Switch/REC8- Spacer Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Primary Codes that pertain: 04, 30 Additional Codes that pertain: 06 Section E- DrawThru Heat Section (RDT) Notes Code 04 determines what type of heat has been specified. DrawThru Heat units normally are hydronically heated with Steam (Code 04= S) OR Hot Water (Code 04= W). NOTE: There are some DrawThru Electric Heat RDT units. See Section G [BlowThru Heat] for all Electric Heat components. Code 30 determines the Hydronic Heating Coil and associated characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 60

61 Section E- DrawThru Heat Section RDT Units Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM) Code 30 first 3 digits = S, S, S3, S4, W, W Coil Location Mixing Valve Detail (HW shown) Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30= Type Height Number Steam Coil- Bottom S*** 5JA060H Steam Coil- Bottom S*** 5JA0H Steam Coil- Bottom S3*** 5JA060C Steam Coil- Bottom S4*** 5JA0C HW Coil- Bottom 7/ & Earlier W*** 5WH090H HW Coil- Bottom 8/ & Later W*** 5WH090H HW Coil- Bottom 7/ & Earlier W*** 5WS090C HW Coil- Bottom 8/ & Later W*** 5WS090C Steam Coil- Top S*** 5JA060H Steam Coil- Top S*** 5JA0H Steam Coil- Top S3*** 5JA060C Steam Coil- Top S4*** 5JA0C HW Coil- Top 7/ & Earlier W*** 5WH090H HW Coil- Top 8/ & Later W*** 5WH090H HW Coil- Top 7/ & Earlier W*** 5WS090C HW Coil- Top 8/ & Later W*** 5WS090C N/S Valve, Way Steam w/ Act..5 S**EE 5JA All S**FE 5JA All S**GE 5JA All S**HE 5JA All VM Actuator- 4V, Valve W****E All All Actuator- 4V, Valve W****E All All Valve, 3 Way HW w/ Actuator.5 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All W**H3E 5WH, 5WS All W**J3E 5WH, 5WS All N/S= Not shown on diagram. Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

62 Section F- Supply Air Section Notes Primary Codes that pertain: 3, 3, 59 (Mid 0 & Later), 08, 4, 5, 40, 49 Additional Codes that pertain: 04, 06, 6, 7, 3 (Mid 0 & Later), Code 33 (Mid 0 & Later), 34 Code 3 determines the Supply Fan size and type, Code 3 determines the Motor horsepower and type, and Code 33 (Mid 0 & Earlier) OR Code 59 (Mid 0 & Later) determine the drive selection. Supply Air Fan Section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 08 determines the location of the unit s Main Control Box. Note that RDT units normally have Main Control Boxes located in the Supply Air Section. Codes 4 & 5 determine if the unit has inverter(s), and if so where they are installed. If Code 4= Y, there are no inverters. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4=,, 4, there is a separate Inverter Section. Code 5 specifies the inverter brand. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied. Code 40 determines the Discharge Plenum configuration. The Discharge Plenum is located in Section F when the section is bolted directly to the condenser (Section M). RDT units always have the Discharge Plenum located in Section F. If Code 40= BE, there is an Isolation Damper with actuator ACT5. This damper is detailed in Section K. Code 49 determines if the Supply Air cabinet has a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), OR both (Code 49= C, F). Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, the location of the Discharge Plenum, as well as the section installed controls. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 6 determines if a Smoke Detector is located in the Supply Air Cabinet. If Code 6=, 3, a Smoke Detector (SD) is present. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 7= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 7 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection. Code 3 (Mid 0 & Later) indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 5V Service Outlet, and/or Intelligent Equipment. Code 33 (Mid 0 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls, Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 3= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

63 Section F- Supply Air Section Forward Curved Fans Low Pressure- FCLP- Code 3= 7F*, 30F*, 33F* or Ref. Part Part Fan Size No. Description Number Motor- see Supply Air Fan Motor Section Housing- Blower Assy Housing- Blower Assy Housing- Blower Assy Wheel Assembly Wheel Assembly Wheel Assembly Screw Adjust Assy Shaft.688 Dia Shaft.937 Dia Shaft.88 Dia Plate, Cutoff Plate, Cutoff Plate, Cutoff Mount Assy- Motor Angle- Motor Mount Hold Down Hold Down Angle- Clamping Plate- Shim Plate- Shim Plate- Shim Key- Fan 4.75 Long Key- Fan 4.75 Long Key- Fan 4.75 Long Key- Sheave 6.00 Long 0346 Key- Sheave 8.50 Long 0356 Key- Sheave 6.50 Long Bearing- Ball Bearing- Ball Bearing- Ball Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 63

64 Section F- Supply Air Section Forward Curved Fans High Pressure- FCMP- Code 3= 7M*, 30M*, 33M* or Ref. Part Part Fan Size No. Description Number Motor- see Supply Air Fan Motor Section Housing- Blower Assy Housing- Blower Assy Housing- Blower Assy Wheel Assembly Wheel Assembly Wheel Assembly Screw Adjust Assy Shaft.688 Dia Shaft.76 Dia Shaft.438 Dia Plate, Cutoff Plate, Cutoff Plate, Cutoff Mount Assy- Motor Angle- Motor Mount Hold Down Hold Down Angle- Clamping Plate- Shim Plate- Shim Plate- Shim Key- Fan 4.75 Long Key- Fan 4.75 Long Key- Fan 9.5 Long 0364 Key- Sheave 6.00 Long 0346 Key- Sheave 8.50 Long 0356 Key- Sheave 6.50 Long Bearing- Ball Bearing- Ball Bearing- Ball Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 64

65 Section F- Supply Air Section Air Foil Fan- Double Width- RPS Units (Code 3= 7A*, 30A*, 33A*) 5 7 A B Ref. Part Part Fan Size No Description Number Motor- see Supply Air Fan Motor Section Housing Assy A Inlet Funnel Only B Cut Off Plate Only Housing Assy A Inlet Funnel Only B Cut Off Plate Only Housing Assy A Inlet Funnel Only B Cut Off Plate Only Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Screw Adjust Assembly Shaft-.88 Diameter Shaft-.438 Diameter Shaft-.438 Diameter Motor Mount Assembly Angle- Motor Mount Holddown Angle, Clamping Key- Fan 9.5 Long X / Diameter 0357 Key- Fan 9.5 Long X 5/8 Diameter 0364 Key- Fan 4.75 Long X 5/8 Diameter 0367 Key- Sheave 6.50 Long X / Diameter 0355 Key- Sheave 6.50 Long X 5/8 Diameter Bearing- Ball Bearing- Ball Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 65

66 Section F- Supply Air Section Air Foil Fan- Single Width- RDT Units Code 3= 40B, 40B, 40B3, 44B, 44B, 44B Ref. Part Part Fan Size No. Description Number Motor- see Supply Air Fan Motor Section 3 Wheel, Fan- Single Inlet/Single Width Wheel, Fan- Single Inlet/Single Width Screw Adjust Assembly Shaft Shaft Mount Assembly-Motor Angle -Motor Mount Angle, Clamping Bearing- Ball Bearing- Ball Key- Fan 4.5 Long X / Diameter 0359 Key- Fan 6.50 Long X 5/8 Diameter 0360 Key- Fan 5.50 Long X / Diameter 0353 Key- Fan 5.50 Long X 5/8 Diameter Tubing- Plastic Tubing- Plastic Inlet Funnel Assembly Inlet Funnel Assembly Fitting- /8 MPT Fitting, Reducer- /4 OD X /8 FPT Fitting Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 66

67 Section F- Supply Air Section Fan Mounts- 7 Forward Curved Fan Code 3= 7F, 7F, 7F3, 7M, 7M, 7M Rubber Mounts Rubber Mounts (Code 3= 7F, 7M) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black , 5 Rubber Mount- Black Rubber Mount- Red , 0-30 Rubber Mount- Red , 5 Rubber Mount- Black All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or 6 Mount Locations 63 or 63 6 or Spring Mounts or Seismic strap used only when Code 3= 7*3. 64 Spring Mounts (Code 3= 7F, 7M) AND Seismic Spring (Code 3= 7F3, 7M3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 7* Seismic Code 3= 7* Spring Mount- Green Spring Mount- Dark Brown , 50 Spring Mount- Red All Spring Mount- Green Spring Mount- Green , 0 Spring Mount- Dark Brown Spring Mount- Red , 50 Spring Mount- Tan All Spring Mount- Dark Brown All Nut Spring Code 3= 7* Seismic Code 3= 7* All Nut All Screw Spring Code 3= 7* 0470 Seismic Code 3= 7* Note that some spring colors have changed during production. The preferred spring combinations are shown above. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 67

68 Section F- Supply Air Section Fan Mounts- 7 Airfoil Double Width Fan Code 3= 7A, 7A, 7A Rubber Mounts Rubber Mounts (Code 3= 7A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black , 5, 0 Rubber Mount- Black , 5-50 Rubber Mount- Red , 5-30 Rubber Mount- Black , 40, 50 Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or 6 Mount Locations 63 or or or Spring Mounts Seismic strap used only when Code 3= 7A Spring Mounts (Code 3= 7A) AND Seismic Spring (Code 3= 7A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 7A Seismic Code 3= 7A Spring Mount- Green Spring Mount- Dark Brown , 50 Spring Mount- Red All Spring Mount- Green Spring Mount- Green , 0 Spring Mount- Dark Brown Spring Mount- Red , 50 Spring Mount- Tan All Spring Mount- Dark Brown All Nut Spring Code 3= 7A Seismic Code 3= 7A All Nut All Screw Spring Code 3= 7A 0470 Seismic Code 3= 7A N/S All Shim Code 3= 7A N/S= Not shown on diagram. Note that some spring colors have changed during production. The preferred spring combinations are shown above. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 68

69 Section F- Supply Air Section Fan Mounts- 30 Airfoil Double Width Fan Code 3= 30A, 30A, 30A Rubber Mounts Rubber Mounts (Code 3= 30A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support , 5 Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Red , 50 Rubber Mount- Green Rubber Mount- Black Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or 6 Mount Locations 63 or 63 6 or 6 64 or Spring Mounts Seismic strap used only when Code 3= 30A Spring Mounts (Code 3= 30A) AND Seismic Spring (Code 3= 30A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 30A Seismic Code 3= 30A Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red All Spring Mount- Green , 7.5 Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Tan All Spring Mount- Dark Brown All Nut Spring Code 3= 30A Seismic Code 3= 30A All Nut All Screw Spring Code 3= 30A 0470 Seismic Code 3= 30A Note that some spring colors have changed during production. The preferred spring combinations are shown above. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 69

70 Section F- Supply Air Section Fan Mounts- 33 Airfoil Double Width Fan Code 3= 33A, 33A, 33A Rubber Mounts Rubber Mounts (Code 3= 33A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red , 5 Rubber Mount- Red Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / or 6 Mount Locations 63 or or or Spring Mounts Seismic strap used only when Code 3= 33A Spring Mounts (Code 3= 33A) AND Seismic Spring (Code 3= 33A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 33A Seismic Code 3= 33A Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Tan All Spring Mount- Green , 7.5 Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Tan All Spring Mount- Dark Brown All Nut Spring Code 3= 33A Seismic Code 3= 33A All Nut All Screw Spring Code 3= 33A 0470 Seismic Code 3= 33A Note that some spring colors have changed during production. The preferred spring combinations are shown above. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 70

71 Section F- Supply Air Section Fan Mounts- 40 AFSW- RDT Units Code 3= 40B, 40B, 40B Rubber Mounts Rubber Mounts (Code 3= 40B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Mount Locations 6 or 6 6 or 6 64 or or Spring Mounts Seismic strap used only when Code 3= 40B Spring Mounts (Code 3= 40B) AND Seismic Spring (Code 3= 40B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 40B Seismic Code 3= 40B Spring Mount- Green Spring Mount- Dark Brown , 5, 40, 50 Spring Mount- Yellow , 30 Spring Mount- Dark Brown Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red Spring Mount- Green Spring Mount- Red , 50 Spring Mount- Dark Brown All Nut Spring Code 3= 40B Seismic Code 3= 40B All Nut All Screw Spring Code 3= 40B 0470 Seismic Code 3= 40B Note that some spring colors have changed during production. The preferred spring combinations are shown above. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

72 Section F- Supply Air Section Fan Mounts- 44 AFSW- RDT Units Code 3= 44B, 44B, 44B Rubber Mounts Rubber Mounts (Code 3= 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Red Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Mount Locations 6 or 6 6 or 6 64 or or Spring Mounts Seismic strap used only when Code 3= 44B Spring Mounts (Code 3= 44B) AND Seismic Spring (Code 3= 44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring Code 3= 44B Seismic Code 3= 44B Spring Mount- Green Spring Mount- Dark Brown All Spring Mount- Dark Brown Spring Mount- Green Spring Mount- Dark Brown Spring Mount- Red All Spring Mount- Red All Nut Spring Code 3= 44B Seismic Code 3= 44B All Nut All Screw Spring Code 3= 44B 0470 Seismic Code 3= 44B Note that some spring colors have changed during production. The preferred spring combinations are shown above. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

73 Section F- Supply Air Section Supply Air Fan Motors Standard Motors: Code 3= **Y H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Code 3= Voltage C3= *EY C3= *JY C3= *HY C3= *KY C09= 3 H*Y 08/60/ J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ P*Y 08/60/ Q*Y 08/60/ R*Y 08/60/ S*Y 08/60/ C09= 9 3 H*Y 30/60/ J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ P*Y 30/60/ Q*Y 30/60/ R*Y 30/60/ S*Y 30/60/ C09= 7 3 H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ R*Y 460/60/ S*Y 460/60/ C09= 37 3 H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ R*Y 575/60/ S*Y 575/60/ Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 73

74 Section F- Supply Air Section Supply Air Fan Motors, Continued Shaft Grounded Motors: Code 3= **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C3= **S Voltage C3= *JS C3= *KS C09= 3 H*S 08/60/ J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ P*S 08/60/ Q*S 08/60/ R*S 08/60/ S*S 08/60/ C09= 9 3 H*S 30/60/ J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ P*S 30/60/ Q*S 30/60/ R*S 30/60/ S*S 30/60/ C09= 7 3 H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ R*S 460/60/ S*S 460/60/ C09= 37 3 H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ Q*S 575/60/ R*S 575/60/ S*S 575/60/ Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 74

75 4 40 Section F- Supply Air Section Belt Guards Code 49= A, C, D, F Air Foil Double Width (AFDW) OR Forward Curved Fans (FCLP, FCMP) Ref. Part Part Fan Size No. Description Number Grille Assembly Grille Assembly Grille Assembly Belt Guard Assembly Belt Guard Assembly Belt Guard Assembly Air Foil Single Width (AFSW) with Side Discharge (Code 40= H), Main Control Box (Code 08= S, F) The Main Control Box is mounted in this section on RDT units. Air Foil Single Width (AFSW) with Side Discharge (Code 40= S), No Control Box (Code 08= P, D) RPS units (Main Control Box is mounted in the Discharge Plenum Section K) Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= G), Main Control Box (Code 08= S, F) The Main Control Box is mounted in this section on RDT units. 83 Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= B), No Control Box (Code 08= P, D, Y) RPS units (Main Control Box is mounted in the Discharge Plenum Section K) Ref. Part Part Fan Size No. Description Number Grille Assy Grille Assy Grille Assy Grille Assy Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 75

76 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/03 & Earlier) Motor HP - 5 (Code = G**, H**, J**; OR Code 3= H**, J**) 7 LR0 (Supply) LR0 (Return) MMP30 (Supply) MMP40 (Return) 70 Bypass Controls Detail 7 M30B/M30I (Supply) M40B/M40I (Return) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 3, 5, 8) Two boxes installed if Code 4= Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) 7 MMP & Contactor Link Detail Motor Horsepower 3 5 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 50 Gasket MMP30, 40 Motor Control LR0, 0 Line Reactor- see page following inverters 7 M30B,I Contactor M40B,I Contact- Auxiliary Link Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 76

77 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/03 & Later) Motor HP - 5 (Code = G**, H**, J**; OR Code 3= H**, J**) MMP30 (Supply) MMP40 (Return) 7 7 LR0 (Supply) LR0 (Return) Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box shown. Phase Barrier (Code 4= 3, 5, 8) Front Mtd. Two boxes installed if Code 4= 5 Aux. Contact 70B 70A MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) Link 70C 7 Contactor MMP30/40 & M30/40 Link Detail HP Motor- All Voltages 3, 5 HP Motors- 460/ Link 70C 7 7A Spacer Contactor MMP30/40 & M30/40 Link Detail 3, 5 HP Motors- 08/30V Motor Horsepower 3 5 Ref. Sch. Part Part No. Sym. Description Number 40 VFD0, 0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 50 Gasket MMP30, 40 Motor Protector A Phase Barrier B Aux. Contact C Link LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I A Spacer Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 77

78 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/03 & Earlier) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) MMP30 (Supply) MMP40 (Return) 7 LR0 (Supply) LR0 (Return) 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) Two boxes installed if C4= 5 7 M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail MMP & Contactor Link Detail MMP p/n xx MMP & Contactor Link Detail MMP p/n , 48, 49 MMP & Contactor Link Detail MMP p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 78

79 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/03 & Earlier) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see page after Inverters 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30, 40 Motor Control LR0, 0 Line Reactor- see page after Inverters 7 M30B,I Contactor M40B,I Contact- Auxiliary Link Interlock- Trip Lug Kit (3 per kit) Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 79

80 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/03 & Later) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) LR0 (Supply) 7 70 LR0 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if C4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Link 70C 7 Link 70C 7A Spacer Contactor 7 Contactor MMP30/40 & M30/40 Link Detail 7.5 HP Motors- Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/30V 5, 0 HP Motors- 0 HP Motors- 5 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 7.5 HP Motors- 08/30/ 0, 5 HP Motors- Phase Barrier 70A Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 80

81 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/03 & Later) Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 50 Gasket MMP30,40 Motor Protector A Phase Barrier B Contact- Auxiliary C Link LR0, 0 Line Reactor- see page after Inverters 7 M30B, I M40B, I Contactor 9A A A A A A A A A Spacer Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

82 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/03 & Earlier) Motor HP (Code = Q** OR Code 3= Q**, R**, S**) Diagrams 7 LR0 (Supply) LR0 (Return) MMP30 (Supply) MMP40 (Return) 50 7 M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 3, 5, 8) Two boxes installed if Code 4= MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n , 48, MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

83 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (03/03 & Earlier) Motor HP (Code = Q** OR Code 3= Q**, R**, S**) Components Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 08V Motor Horsepower V 08V 30V 08V 30V 50 Gasket MMP30 Motor Control MMP LR0, 0 Line Reactor- see page after Inverters 7 M30B,I Contactor M40B,I Contact- Auxiliary Link Interlock- Trip Lug Kit (3 per kit) Also requires 3 ring terminals. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 83

84 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/03 & Later) Motor HP (Code = Q** OR Code 3= Q**, R**, S**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air OR Return Air Fan Inverter without Bypass. (Code 4= 7, 9) LR0 (Supply) 7 70 LR0 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air OR Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code 4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Front Mtd. Aux. Contact 70B MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Link 70C Link 70C 7 7 Contactor Contactor MMP30/40 & M30/40 Link Detail 30 HP Motors- 460/ 40 HP Motors- Contactors 7 MMP30/40 & M30/40 Link Detail 30 HP Motors- 08/30V 40 HP Motors- 50 HP Motors- 460/ Overload 78 Interlock 79 MMP30/40 & M30/40 Link Detail 40, 50 HP Motors- 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 84

85 Section F- Supply Air Section Inverters & Inverter Bypass Control Box: (04/03 & Later) Motor HP (Code = Q** OR Code 3= Q**, R**, S**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see next page 08V 30V 08V 30V 08V 30V 50 Gasket MMP30 Motor Protector MMP A A A A A A Phase Barrier B Contact- Auxiliary C Link LR0, 0 Line Reactor- see page after Inverters 7 M30B,I Contactor 50A M40B,I 5A A A A A A OL30 Overload 50-00A OL A Mechanical Interlink N/S CB30, 40 Circuit Breaker 50A N/S= Not Shown on Diagram. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 85

86 Section F- Supply Air Section Inverters Code 5= R Motor Horsepower /30V Part Number /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 86

87 Section F- Supply Air Section Inverters, Continued Code 5= A AND/OR Code 3 (Mid 0 & Later)= **A** 08/30V Motor Horsepower, /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number The replacement VFD Keypad Display is p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 87

88 Section F- Supply Air Section Inverters, Continued Code 5= G Motor Horsepower Part Number Part Number 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V Motor Horsepower V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 88

89 Section F- Supply Air Section Inverters, Continued Code 5= S, Q AND/OR Code 3 (Mid 0 & Later)= **Q** 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number , , , , , , , Early production units (late 00 & earlier) shipped with ATV VFDs. All ATV drives have been replaced with ATV drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV Remote Keypad is p/n The ATV Lonworks communication card is p/n The ATV Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The ATV Lonworks communication card is p/n All other ATV communication cards are integral to the VFD and are not available separately. Note that since the original ATV drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV part fails, the entire drive must be replaced. MD3 Remote Keypad p/n is MD6 Remote Keypad p/n is plus Mount p/n For units with an MD3 Inverter and Motor under 5 HP a Line Reactor will be installed regardless of whether one is specified in Code 7 (see nomenclature page). See one page after next for Line Reactor part numbers. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 89

90 Section F- Supply Air Section Inverters, Continued Code 5= B OR Code 3 (Mid 0 & Later)= **B** 08/30V Motor Horsepower /30V 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V Part Number The replacement VFD Keypad Display is p/n /30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 90

91 Section F- Supply Air Section Line Reactors 08V/30V Motor Horsepower V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V 08V/30V Part Number Line Reactors are used when Code 7= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7,, Y8; except for MD3 Inverters (Code 5= S, Q ) - 0 HP. These will always have a Line Reactor installed regardless of Code 7. These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

92 Section F- Supply Air Section Section Mounted Controls PC7, HL, LT0, S0, REC0, UV Lights PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket 9 Pressure Control- PC7 0 Pneumatic Fitting In mid 0 the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 9043 for proper installation as old and new parts are NOT interchangeable. The Switch only is p/n , the Pneumatic Fitting is p/n 9044, and the Support Bracket is p/n HL- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 67 T-stat- HL Hi Limit LT0- Supply Fan Light/S0- Supply Fan Light Switch/REC0- Supply Fan Receptacle Code 49= B, E Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC UV Lights Code 7= C thru C8 AND Y thru Y8 Ref. Part Part Qty. No. Description Number 98 Light Fixture- 8 Bulb Light Fixture- 4 Bulb Light Fixture- 36 Bulb Bulb/Lamp, UV Bulb/Lamp, UV Bulb/Lamp, UV Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

93 Section F- Supply Air Section Section Mounted Controls MAT, EFT, SAT, DAT, OAT, SD 5 Mixed Air Temperature Sensor- MAT OR Entering Fan Temperature Sensor- EFT Ref. Part Part Qty. No. Description Number 5 EFT/MAT Temp. Sensor MAT/EFT Supply Air Temperature Sensor- SAT OR Discharge Air Temperature Sensor- DAT 8 Ref. Part Part Qty. No. Description Number 8 SAT/DAT Temp. Sensor SAT/DAT 7 Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 OAT Temp. Sensor OAT Smoke Detector Detail 5 50 Smoke Detector- SD Code 6=, 3 Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD Sensing Tube Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 93

94 Section F- Supply Air Section Section Mounted Controls SCB- Split Junction Box (Code 05= F) TB5, TB7, TB8, PB0, PB9, PB0, PB9 TB8 TB7 TB5 PB 9 PB 0 PB 9 PB 0 Motor HP , 50 Sch. Part Part Sym. Description Number Terminal Blocks TB5 Terminal Block- SCB TB7 Terminal Block- SCB TB8 Terminal Block- SCB PB0 Power Block- Supply Fan 95A, 600V, 3P PB9 Power Block- Supply Fan 95A, 600V, 3P PB0 Power Block- Return Fan 95A, 600V, 3P PB9 Power Block- Return Fan 95A, 600V, 3P Only used when the unit has a supply fan inverter OR an Economizer with a Power Closure Exhaust Damper. 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 94

95 Section G- BlowThru Heat Section Notes Primary Codes that pertain: 04, 34 Additional Codes that pertain: 06, 07, 09,, 3 This section is divided into four subsections:. Blank/Empty Section;. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat. Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section s characteristics. If Code 04= Y, and Code 34= YYYYYY there is no section. If Code 04= Y and Code 34= BBBBBB, then there is a 48 Blank Access Section installed. Code 06 determines the insulation and liners and will affect the Top Panel, Uprights, and Door Assembly part numbers. For sheet metal components that make up the BlowThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is ETA/MEA approved (USA) OR ETL approved (Canada). Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls. Code determines the Control type and will affect the Gas Heat Actuator. Code 3 is the Supply Fan size, and affects the heat section s Diffusers. Option : Blank/Empty Section Code 34= BBBBBB AND Code 04= Y Diffuser Ref. Part Part Qty. No. Description Number Diffuser 7 Supply Fan Code 3= 7** Supply Fan Code 3= 30** Supply Fan Code 3= 33** Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 95

96 Section G- BlowThru Heat Section Option : Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM) Code 34 first 3 digits = S, S, S3, S4, W, W Diffuser Coil Location Mixing Valve Detail (HW shown) Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number Steam Heat Coil- Bottom S*** 5JA060H Steam Heat Coil- Bottom S*** 5JA0H Steam Heat Coil- Bottom S3*** 5JA060C Steam Heat Coil- Bottom S4*** 5JA0C Hot Water Heat Coil- Bottom W*** 5WH090H Hot Water Heat Coil- Bottom W*** 5WS090C Steam Heat Coil- Top S*** 5JA060H Steam Heat Coil- Top S*** 5JA0H Steam Heat Coil- Top S3*** 5JA060C Steam Heat Coil- Top S4*** 5JA0C Hot Water Heat Coil- Top W*** 5WH090H Hot Water Heat Coil- Top W*** 5WS090C N/S FS Freezestat ALL ALL ALL Diffuser- 7 Supply Fan Diffuser- 30 Supply Fan Diffuser- 33 Supply Fan N/S Valve, Way Steam Heat w/ Act..5 S**EE 5JA All S**FE 5JA All S**GE 5JA All S**HE 5JA All VM Actuator- 4V, Valve W****E All All Actuator- 4V, Valve W****E All All Valve, 3 Way HW w/ Actuator.5 W**E3E 5WH, 5WS All W**F3E 5WH, 5WS All W**G3E 5WH, 5WS All W**H3E 5WH, 5WS All W**J3E 5WH, 5WS All N/S= Not shown on diagram. Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY. Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and serial number information so that the correct Actuator can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 96

97 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit= E Heaters, Diffusers, Hi Limit Cutouts HL- 0, 3-50 Diagram & Components 5 Air Flow 7 7A 6 Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 5 Heater Assy- Top 40 E Heater Assy- Top 40 E Heater Assy- Top 40 E N/A Heater Assy- Top 60 E Heater Assy- Top 60 E Heater Assy- Top 60 E N/A Heater Assy- Top 80 E Heater Assy- Top 80 E Heater Assy- Top 80 E N/A Heater Assy- Top 00 E Heater Assy- Top 00 E Heater Assy- Top 00 E00 00 N/A Heater Assy- Top 0 E Heater Assy- Top 0 E Heater Assy- Top 0 E0 0 N/A Heater Assy- Top 60 E Heater Assy- Top 60 E Heater Assy- Top 60 E60 60 N/A Heater Assy- Top 00 E Heater Assy- Top 00 E Heater Assy- Top 00 E00 0 N/A Heater Assy- Top 40 E Heater Assy- Top 40 E Heater Assy- Top 40 E40 0 N/A N/A= Not Applicable. Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches. Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches. 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 97

98 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit= E Heaters, Diffusers, Hi Limit Cutouts HL- 0, 3-50 Components, Continued Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 6 Blank Assy- Bottom E/ Heater Assy- Bottom 00 E Heater Assy- Bottom 00 E Heater Assy- Bottom 00 E00 80 N/A Heater Assy- Bottom 40 E Heater Assy- Bottom 40 E Heater Assy- Bottom 40 E40 0 N/A HL- 0 Hi Limit- Manual Cutout All All All N/A var var var 7A HL3-50 Hi Limit- Auto Cutout All All All var var var Diffuser All All All N/A= Not Applicable. Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches. Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches. 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 98

99 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit= E Electric Heat Control Box: (03/03 & Earlier) FB33 FB37 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB33 FB3 FB3 M33 M37 M3 M36 M3 M35 FB34 FB38 H S 3 M33 M3 M3 FB34 H S 3 M33 FB43 M3 FB4 M3 FB4 H S 3 T B M34 T B M43 M4 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 08/30V 0KW- 60KW DS3 or PB3 460/ 0KW- 60KW DS3 or PB3 460/ 00KW- 40KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Amps Switch Handle Shaft Ground Lug DS3 Disconnect Switch 00 Amp Disconnect Switch 50 Amp Disconnect Switch 50 Amp Disconnect Switch 400 Amp Disconnect Switch 600 Amp Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS3 size. Includes mechanism (except 600A switch, see footnote 4). 3 The original M frame Disconnect is obsolete and has been replaced with a P frame switch. Due to dimensional differences minor field modifications may be required for proper installation. 4 Handle only p/n ; Mechanism only p/n ; Shaft p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 99

100 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit= E Electric Heat Control Box: (03/03 & Earlier) 0-0KW Components Heater KW Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block 3 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V HS3 Switch TB Terminal Block M3 Contactor Contactor M3 Contactor Contactor M33 Contactor Contactor M34 Contactor Contactor M35 Contactor M36 Contactor Part number is for one section. The number of sections used is determined by the options installed. See chart on previous page. 3 Not Used when PB3 Power Block connection is present. 4 Cover- PB3 for 600A DS3= p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 00

101 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (03/03 & Earlier) 0-0KW Components, Continued Heater KW Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

102 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (03/03 & Earlier) 60-40KW Components Heater KW Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block 3 used w/00a/50a DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch HS3 Switch TB Terminal Block V 30V M3 Contactor M3 Contactor M33 Contactor M34 Contactor M35 Contactor M36 Contactor M37 Contactor M38 Contactor M4 Contactor M4 Contactor M43 Contactor Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Not Used when PB3 Power Block connection is present. 4 Cover- PB3 for 600A DS3= p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

103 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (03/03 & Earlier) 60-40KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block FB37 Fuse Block FB38 Fuse Block FB4 Fuse Block FB4 Fuse Block FB43 Fuse Block V 30V F3 Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB F37 Fuse- FB F38 Fuse- FB F4 Fuse- FB Fuse- FB F4 Fuse- FB Fuse- FB F43 Fuse- FB Fuse- FB Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 03

104 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (04/03 & Later) Diagrams & Components FB33 FB37 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB33 FB3 FB3 M33 M37 M3 M36 M3 M35 FB34 FB38 H S 3 M33 M3 M3 FB34 H S 3 M33 FB43 M3 FB4 M3 FB4 H S 3 T B M34 T B M43 M4 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 08/30V 0KW- 60KW DS3 or PB3 460/ 0KW- 60KW DS3 or PB3 460/ 00KW- 40KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 00A Not Used Not Used Disconnect Switch- 50A Disconnect Switch- 50A Disconnect Switch- 400A Disconnect Switch- 600A Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. This Shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This Shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 04

105 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (04/03 & Later) 0-0KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block 75A Power Block 40A PB3 Power Block 3 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V HS3 Switch TB Terminal Block M3 Contactor 40A Contactor A M3 Contactor 40A Contactor A M33 Contactor 40A Contactor A M34 Contactor 40A Contactor A M35 Contactor 40A M36 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. See the chart on the previous page. 3 Not Used when PB3 Power Block connection is present. 4 Cover- PB3 used with 600A DS3 is p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 05

106 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (04/03 & Later) 0-0KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block V 30V 08V 30V 08V 30V 08V 30V 08V 30V 08V 30V F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 06

107 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (04/03 & Later) 60-40KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block 3 used w/00a/50a DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch HS3 Switch TB Terminal Block V 30V M3 Contactor 40A M3 Contactor 40A M33 Contactor 40A M34 Contactor 40A M35 Contactor 40A M36 Contactor 40A M37 Contactor 40A M38 Contactor 40A M4 Contactor 40A M4 Contactor 40A M43 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Not Used when PB3 Power Block connection is present. 4 Cover- PB3 for 600A DS3= p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 07

108 Section G- BlowThru Heat Section Option 3: Electric Heat: Code 34 first digit = E Electric Heat Control Box: (04/03 & Later) 60-40KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block FB37 Fuse Block FB38 Fuse Block FB4 Fuse Block FB4 Fuse Block FB43 Fuse Block V 30V F3 Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB F37 Fuse- FB F38 Fuse- FB F4 Fuse- FB Fuse- FB F4 Fuse- FB Fuse- FB F43 Fuse- FB Fuse- FB Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 08

109 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers & Vestibules 00, 50 MBH Furnaces Code 34= 00**, 05** Heat Exchanger Burner 3 38 Burner Control Box 4 Gas Train 5 Ref. Part 00, 50 Qty. No. Description MBH Heat Exchanger Kit Vestibule Vestibule Capillary Plate N/S Turbulator Assy N/S= Not shown on diagram. Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket. Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulator Assemblies must be ordered separately. 3 Parts detail follows this section. 4 Parts detail follows Burner section. 5 Parts detail follows Burner Control Box section. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 09

110 Section G- BlowThru Heat Section Option 4- Gas Heat Code 04= A Heat Exchangers & Vestibules 30, 400, 500, 640, 650, 790, 800, 000 MBH Furnaces Code 34= 03**, 040**, 050**, 064**, 065**, 079**, 080**, 00** Heat Exchanger 300 Burner 3 Burner Control Box 4 Gas Train 5 Ref. Part 30, , , , 000 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger Kit Vestibule Vestibule N/S Turbulator N/S= Not shown on diagram. Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket. Quantity varies depending upon the size of the Heat Exchanger. For 30/400 MBH order 6 pc.; for 500/640 MBH order 9 pc.; for 650/790 MBH order pc.; for 800/000 MBH order 5 pc. Note that Turbulators are NOT furnished with the Heat Exchanger Kit. 3 Parts detail follows this section. 4 Parts detail follows Burner section. 5 Parts detail follows Burner Control Box section. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

111 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Diagrams Burner Control Box , 50, 30 MBH Burners MBH Burners Pilot Valve/ Pressure Regulator Assy Detail 60 Burner Control Box Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

112 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Components Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 0 Burner Housing Scroll Wheel-.5 bore Motor-.5 HP, 5/60/ Gun Assembly 00 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace Pilot Mixer Pilot Assembly Damper Assembly Blast Tube Gasket Right Side Damper MBH Furnace MBH Furnace MBH Furnace Left Side Damper MBH Furnace MBH Furnace Slide Damper 00 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

113 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Components, Continued Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 7 Blower Gasket Burner Cover Ignition Assembly 0 Glass Cover Glass Cover Support Orifice 00 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Clip Flange Bearing Air Switch Tube Pilot Burner Tube MBH Furnace MBH Furnace Compression Fitting Pilot Tube Manual Cock Valve MBH only Not Used Press. Reg. Valve MBH only Not Used º Comp. Elbow MBH only Not Used Motor Conduit Box MBH only Torsion Spring Not Used Burner Box Baffle MBH Furnace MBH Furnace Valve- Pressure Regulator Valve- Manual: MBH Valve- Solenoid: MBH N/S Flame Rod N/S Ignition Electrode Assy N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

114 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Diagrams MBH MBH Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

115 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 0 Burner Housing Scroll MBH Furnace MBH Furnace Wheel-.5 bore MBH Furnace MBH Furnace Motor-.5 HP, 5/60/ MBH Furnace MBH Furnace Gun Assembly 00 MBH Furnace N/A 50 MBH Furnace N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube MBH Furnace MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

116 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 0 Orifice Assembly 00 MBH Furnace N/A 50 MBH Furnace N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace & 800 MBH Furnace MBH Furnace Gasket- Blast Tube Air Box Assy Plate- Actuator Scale Gasket- Blower Panel- Burner Box Cover Ignition Wire Assy 0 Glass Cover- Burner Support- Glass Cover Grommet- Flat Box- Conduit Motor- Actuator 0V Motor- Actuator 4V Control Arm Control Rod Crank Arm Extension- Crank Arm Bushing- Control Rod Linkage Plate- Adjustable 00 MBH Furnace N/A 50 MBH Furnace N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace N/A= Not available. Normally units without controls (Code = YM, YC) use a 0V Actuator and units with controls (Code = *E, *F, *W) use a 4V Actuator. Confirm voltage required BEFORE ordering. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

117 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Components, Continued Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 3 Plate- Profile 00, 50 MBH Furnaces N/A 30 MBH Furnace N/A 400 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Plate- Slide Damper 00, 50, 30, 400 MBH Furnaces MBH Furnace , 650 MBH Furnaces , 800, 000 MBH Furnaces Box- Air MBH Furnaces MBH Furnaces Gasket- Air Box Grommet Bearing- Sleeve Grommet MBH only Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

118 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls: Code 34= ****E*, ****R*, ****S* No Controls (Code = YM, YC) Diagram FSG Detail Gas Control Box Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

119 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls: Code 34= ****E*, ****R*, ****S* No Controls (Code = YM, YC) Components Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 00, GV Pressure Reg. Assy Valve Only Manual Cock Valve Not Used Solenoid Valve Not Used Not Used Support Not Used 4 Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada S3 Toggle Switch- 4PST: S IT Ignition Transformer Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper, Row Terminal Block Jumper, 3P Fitting Bushing R0 Relay (Before /0) N/S R0A Relay (After /0) N/S Relay Socket R3 Pilot Relay (Before /0) N/S R3A Pilot Relay (After /0, ETL only) N/S Mounting Adapter N/S R3B Pilot Relay (After /0) N/S Relay Socket N/S= Not Shown on diagram. Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

120 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner Controls (Code 34= ****E*, ****R*, ****S*) MicroTech III Controls (Code = *E, *F, *W) R3B IT 5 4 R3A Gas Control Box FSG Detail R0A AS TB FLC Panel Detail S3 GV Detail FSG 5 Ref. Sch. Part Furnace MBH: Qty. No. Sym. Description 00, GV Pressure Reg. Assy Valve Only Manual Cock Valve Not Used Solenoid Valve Not Used Not Used Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada S3 Toggle Switch- 4PST IT Ignition Transformer AS Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Block Terminal Block End Stop Terminal Block End Plate Jumper Terminal R0A Relay- High Amp DPDT/0V R3A Relay- High Amp DPDT/0V R3B Relay- Low Amp DPDT/0V Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

121 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U* No Controls (Code = YM, YC) Diagram TB TD R R0 6 R FSG Detail 64 See Detail 9 R Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

122 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U* No Controls (Code = YM, YC) Components Ref. Sch. Part Part Qty. No. Sym. Description Number Support Support Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper, Row Terminal Block Jumper, 3P Fitting Bushing Bushing R0 Relay 0V (Before /0) N/S R0A Relay 0V (After /0) N/S Mounting Adapter N/S R0B Relay 0V (After /0) Relay Socket R3 Relay- 0V/DPDT (Before 3/0) N/S R3A Relay 0V (After /0) N/S Mounting Adapter N/S R3B Relay- 0VSPST (After 3/0) Relay Socket R Relay- 0V/DPDT (Before 3/0) R Relay- 0V/DPDT (After 3/0) Relay Socket R Relay- 0VSPST (Before 3/0) R Relay- 0VSPST (After 3/0) N/S Mounting Adapter TD0 Relay- Time Delay 0.0 Sec N/S= Not Shown on diagram. Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

123 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U* MicroTech III Controls (Code = *E, *F, *W) R IT R0B 6 R0A FLC AS 3 LS LS TB 4 33 LS, 5 9 S3 6 7 FSG FSG Detail Ref. Sch. Part Part Qty. No. Sym. Description Number 4 Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS/LS Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate Terminal Block Jumper R0A Relay-High Amp DPDT/0V R0B Relay- Low Amp DPDT/0V R Relay- Low Amp DPDT/0V Note that the sensor is NOT sold separately from the controller. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

124 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Inlet Units without Pressure Regulator Valve Code 34= ****E* Gas Flow MBH MBH Ref. Part Part Qty. No. Description Number 05 Shutoff Valve MBH Gas Valve 00, 50, 30 MBH , 500 MBH MBH Units with Pressure Regulator Valve Code 34= ****R*, ****S* Gas Flow 00, 50, 30 MBH Furnaces , 500, 640, 650, 800 MBH Furnaces MBH Furnaces Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 05 Shutoff Valve MBH Pressure Regulator 00, 50, 30 MBH MBH MBH , 650 MBH , 800 MBH MBH Gas Valve 00, 50, 30 MBH , 500 MBH MBH Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

125 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Inlet Canada Units Code 07= CC, CD Units without Pressure Regulator Valve Code 34= ****H* 6 Combination Valve Detail Back Wall of Vestibule 9 Ref. Part Part Qty. No. Description Number 6 Gas Valve 00, 50, 30 MBH , 500 MBH MBH Combination Valve Units with Pressure Regulator Valve Code 34= ****T*, ****U* 3 Back Wall of Vestibule Gas Flow MBH MBH Combination Valve Detail Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 6 Shutoff Valve 00, 50, 30 MBH , 500 MBH MBH Pressure Regulator 00, 50, 30 MBH MBH MBH , 650 MBH , 800 MBH MBH Valve- Combination Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

126 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Inlet UL Units Code 07= EU, YU Units without Pressure Regulator Valve Code 34= ****H* 6 Ref. Part Part Qty. No. Description Number 6 Gas Valve 00, 50, 30 MBH , 500 MBH MBH Units with Pressure Regulator Valve Code 34= ****T*, ****U* 3 6 Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 6 Shutoff Valve 00, 50, 30 MBH , 500 MBH MBH Pressure Regulator 00, 50, 30 MBH MBH MBH , 650 MBH , 800 MBH MBH Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

127 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Controls: GV, GV3 UL Units Code 07= EU, YU 48 Gas Controls: 00, 50, 30 MBH Furnace MBH Furnaces Ref. Part Part Qty. 6 No. Description Number 48 Gas Valve- GV Junction Box Junction Box Cover Gas Pipe 00, 50 MBH GV 30 MBH MBH Furnaces UL Approved (Code 07= EU, YU) 53 GV 56 GV Gas Controls: MBH Furnace UL Approved Ref. Part Part Qty. No. Description Number 48 Gas Valve- GV, GV3 400, 500 MBH MBH Pressure Regulator 400, 500 MBH MBH Junction Box Junction Box Cover Gas Pipe 400, 500 MBH MBH , 790 MBH , 000 MBH Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

128 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Modulating Burner: Code 34= ****E*, ****R*, ****S* Gas Train- Controls: GV, VM Canada Units Code 07= CC, CD 48 Gas Controls: 00, 50, 30 MBH Furnace MBH Furnaces Ref. Part Part Qty. 6 No. Description Number 48 Gas Valve- GV Junction Box Junction Box Cover Gas Pipe 00, 50 MBH GV 30 MBH MBH Furnaces Canada Approved (Code 07= CC, CD) GV 6 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 48 Gas Valve Body- GV 400, 500 MBH MBH Actuator- VM Pressure Regulator 400, 500 MBH MBH Gas Pipe 400, 500 MBH , 650 MBH MBH , 000 MBH Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

129 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Gas Train- Controls: GV, GV, GV4, GV5, GV MBH Furnaces GV 54 Gas Controls: 00, 50, 30 MBH Furnace Ref. Part Part Qty. No. Description Number 54 Gas Valve- GV N/S Junction Box N/S Junction Box Cover N/S= Not shown on diagram MBH Furnaces UL Approved (Code 07= EU, YU) GV4 GV MBH Furnaces UL Approved (Code 07= EU, YU) GV5 GV4 54 GV Gas Controls: MBH Furnace UL Approved Ref. Part Part Qty. No. Description Number 54 Gas Valve- GV, GV MBH Gas Valve- GV,GV4,GV MBH MBH Furnaces Canada Approved (Code 07= CC, CD) 47 GV GV5 GV MBH Furnaces Canada Approved (Code 07= CC, CD) GV6 47 GV5 GV 46 GV4 54 Gas Controls: MBH Furnace Canada Approved Ref. Part Part Qty. No. Description Number 46 Gas Valve Body- GV 400, 500 MBH MBH Actuator- GV Gas Valve- GV4, GV MBH Gas Valve- GV4,GV5,GV MBH Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

130 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Outlet MBH MBH Modulating Burners Code 34= ****E*, ****R*, ****S* Actuator & Linkage- See next page Ref. Part Part Qty. No. Description Number 75 Pipe w/ Valve Mount MBH MBH MBH MBH Butterfly Valve MBH , 500 MBH MBH Shutoff Valve MBH , 500 MBH MBH MBH Canada MBH UL Actuator & Linkage- See next page MBH Hi Turn Down Burners Code 34= ****H*, ****T*, ****U* MBH 75 Ref. Part Part Qty. No. Description Number 75 Gas Valve MBH , 500 MBH MBH Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 30

131 Section G- BlowThru Heat Section Option 4- Gas Heat: Code 04= A Gas Train- Damper Linkage Modulating Burners w/ VM Actuator Code 34= ****E*, ****R*, ****S* 97 Burner Box 95 Butterfly Valve (see previous page) 97 Burner Box 95 Butterfly Valve (see previous page) VM Actuator Switch Kit Transformer Canada Actuator Detail UL Units Canada Units (00-30 MBH) Canada Units ( MBH) Ref. Part Furnace MBH Qty. No. Description Actuator Motor- VM Units w/ MicroTech III Controls USA Units Canada Units Units w/ No Temp. Ctl. (Code = YC) All Units Before / All Units After / Units w/ No Temp. Ctl. (Code = YM) UL Units Canada Units Crank Arm Ball Joint Linkage Arm Crank Arm Extension Arm (Canada Units Only) Not Used Air Damper Lever Arm Gas Valve Arm Assembly part number. Motor only is p/n 3050, and Interface Kit only is p/n Assembly part number. Motor only is p/n 35780, and Switch Kit only is p/n Assembly part number. Motor only is p/n 04770, and Switch Kit only is p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

132 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 00 MBH and 50 MBH Furnace Code 04= A AND Code 34= 00***, 05*** Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 05 Door Assembly Door Assembly Back- Flue Box Flue Box Mount Sleeve Bearing Door Catch Gasket Gasket Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

133 Section G- BlowThru Heat Section Option 4- Gas Heat w/ 30 MBH thru 000 MBH Furnace Code 04= A AND Code 34= 03***,040***,050***,064***,065***,079***,080***, 00*** Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly 30, 400 MBH , 640 MBH , 790 MBH , 000 MBH Inspection Door Back- Flue Box 30, 400 MBH , 640 MBH , 790 MBH , 000 MBH Angle- Flue Box 30, 400 MBH , 640 MBH , 790 MBH , 000 MBH Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket Hinge Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 33

134 Section H- BlowThru Heat Blank Access Section Notes AND Access Door Latching Assemblies, Key, & Lock Primary Codes that pertain: 38 Additional Codes that pertain: 34, 06 Code 38 determines the section s characteristics. If Code 38= Y, there is no section. If Code 38= B, F there is a 48 BlowThru Blank/Empty section. If Code 38= E there is a 4 Blank/Empty section. If Code 38= G, H, there is a Straight Attenuator. If Code 38= K, L there is a Straight Attenuator with Tedlar coating. If Code 38= J there is an Elbow Attenuator. If Code 38= M there is an Elbow Attenuator with Tedlar coating. Code 34 determines the BlowThru Heat Section (Section G). There has to be a Section G in order for there to be a Section H, therefore Code 34 CANNOT= YYYYYY. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heat Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. Door Hardware and Gasketing Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing N/S Door Catch N/S Gasket- Horizontal N/S Gasket- Vertical N/S= Not Shown on diagram. If the unit is split at the fan and heat sections (Code 05= F) use p/n Access Door Latching Assemblies, Key, & Lock (All Sections) Ref. Part Part Qty. No. Description Number 0 Door Latching Assy.- LH, 73" Section 4 var. 0 Door Latching Assy.- RH, 73" Section 4 var. 0 Door Latching Assy.- LH, 97 Section 4 var. 0 Door Latching Assy.- RH, 97 Section 4 var. N/S Access Door Key var. N/S Access Door Lock 0370 var. N/S= Not Shown on diagram. These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Once the door handing is determined, it is then necessary to determine the height of the section. The 73" Latching Assembly is used for unit sections 73 inches high (most sections) and the 97" assembly is used for 97" high sections (eg. Section A Energy Recovery [Code 0= *E]). 0 0 Door Latching Assy. Left Hand Door Latching Assy. Right Hand Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 34

135 Section I- BlowThru Cooling Section Notes Primary Codes that pertain: 03, 35, 36 Additional Codes that pertain: 06 Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil, and if Code 03= L there is a large face area Coil. Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 48 section. If the first three digits of Code 35= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P, Y in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T, the first three digits of Code 35 must be DYY. Code 36 determines the Cooling Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. NOTE: See Section D for all parts used in Section I. Although the section location is different within the unit configuration, the components are identical. Section Mounted Controls LT6, S6, REC LT6- BT Cooling Section Light/S6- BT Cooling Section Light Switch/REC6-BT Cooling Section Receptacle. Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 35

136 Section J- Final Filter Section Notes Primary Codes that pertain: 39 Additional Codes that pertain: 04, 33 (Mid 0 & Later), 34 Code 39 determines all of the section characteristics. If Code 39= A, J, B, K, E, L, F, M, G, N, H there are filters; if Code 39= C, D, Q, R, S, T then there is a Blank/Empty Section. If Code 39= Y, there is no section. Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts. Code 33 (Mid 0 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description. Door Hardware and Gasketing Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing N/S Door Catch N/S Gasket- Horizontal N/S Gasket- Vertical N/S= Not Shown on diagram. If the unit is split at the fan and heat sections (Code 05= F) use p/n Section Mounted Controls HL3 Gas Hi Limit Control: Code 04= A AND Code 39= DOES NOT= Y PC6 Clogged Filter Control: Code 39= DOES NOT= Y, C, Q, D, R, S, T Gas Hi Limit Control Clogged Filter Control 387 Unit Air Flow Control HL3 Gas Heat Hi-Limit (Firestat) Supplied with PC6 Harness from Main/ Split Box Unit Base Ref. Part Part Qty. No. Description Number 386 Stat Support HL3 Firestat Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 36

137 Section J- Final Filter Section Filters Flat Filter Rack- Code 39= A, E, J, G, N 4A 4 5A 5 Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 4 x 4 x High Heat A, E A, J Filter- 95% Eff- Cartridge, 4 x 4 x Standard S, W A, J Filter- 95% Eff- Cartridge w/ Intersept, 4 x 4 x ALL ALL E, L 8 Filter- 95% Eff- HEPA Cartridge, 4 x 4 x ALL ALL G, N 8 4A Gasket- Filter High Heat A, E ALL Gasket- Filter Standard S, W ALL Filter- 95% Eff- Cartridge, x 4 x High Heat A, E A, J Filter- 95% Eff- Cartridge, x 4 x Standard S, W A, J Filter- 95% Eff- Cartridge w/ Intersept, x 4 x ALL ALL E, L 4 Filter- 95% Eff- HEPA Cartridge, x 4 x ALL ALL G, N 4 5A Gasket- Filter High Heat A, E ALL Gasket- Filter Standard S, W ALL Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 37

138 Section J- Final Filter Section Filters, Continued Staggered Filter Rack- Code 39= B, F, K, M 4 4A 5 5A 4 4A Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 4 x 4 x High Heat A, E B, K Filter- 95% Eff- Cartridge, 4 x 4 x Standard S, W B, K Filter- 95% Eff- Cartridge w/ Intersept, 4 x 4 x ALL ALL F, M 8 4A Gasket- Filter High Heat A, E B, K Gasket- Filter Standard S, W B Filter- 95% Eff- Cartridge, x 4 x High Heat A, E B, K Filter- 95% Eff- Cartridge, x 4 x Standard S, W B, K Filter- 95% Eff- Cartridge w/ Intersept, x 4 x ALL ALL F, M 8 5A Gasket- Filter High Heat A, E B, K Gasket- Filter Standard S, W B, K Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 38

139 Section K- Discharge Plenum Section- RPS OR RFS Notes Primary Codes that pertain: 40 Additional Codes that pertain: 6,, 6, 34, 35, 36, 38, 39, 4. Code 40 determines the discharge direction. RPS, RFS units may have bottom discharge (Code BE, BY) OR side discharge (Code LY, RY, SY). RFS units may also have front discharge (Code FY). The VAV Damper option is Code *E. Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. Code, Disconnect Switch option, influences Access Door part numbers. Code 6 determines Smoke Detectors. If Code 6=, 3 there is a Supply Air Smoke Detector (SD). For RPS and RFS units with heat the SD is in Section K. For RDT units, OR RPS, RFS DrawThru cooling only units (units with no separate discharge plenum section) SD is in the Supply Air section (Section F). Codes 34-39, the BlowThru/Final Filter section codes, and Code 4, the special Blank/Empty Section code, pertain to some of the final assembly part numbers. If there is no BlowThru final section then the Discharge Plenum is attached directly to the Supply Air Section and some of the final assembly part numbers are different than they are if the BlowThru section is present. If Code 4= Y (no Blank Access Compartment), then the Discharge Plenum end panels are painted. If the Blank/Empty Section is present then the end panels are unpainted. Note: The RPS and RFS Main Control Box is located in the Discharge Plenum Section. However, Main Control Box components are listed in Section N. Section Mounted Controls OAT, DAT, SD OAT 7 DAT 8 Discharge Air Temperature Sensor- DAT & Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor- OAT DA Temp. Sensor- DAT Smoke Detector Detail 5 50 Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD Sensing Tube Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 39

140 Section K- Discharge Plenum Section Discharge Damper Assembly- w/ Actuator ACT5 Code 40= BE ACT5 Actuator Linkage Detail Ref. Part Part Number Qty. No. Description C40= BE Complete Damper Assy. w/ Actuator Motor Mount Blade Angle- Linkage Blade- Angle Shaft- Damper Linkage- Shaft Bearing, Flange- Damper Actuator, 4V ACT Crank Arm Ball Joint Bearing- Sleeve Gasket Support- Actuator Retainer- Actuator Bearing- Sleeve NOTE: This Discharge Damper and ACT5 Actuator assembly may also be located in Section F (Supply Air). The Discharge Air opening is in the Supply Air section on RDT units, and RPS OR RFS DrawThru units with no BlowThru heat (applications where Section F is attached directly to the condensing unit, OR is the end of the unit). Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 40

141 Section L- Out-of-Airstream Blank Access Section Notes Primary Codes that pertain: 4 If Code 4= Y, there is no Blank/Empty Section. If Code 4=, there is a 48/4 Blank/Empty Section with Access Doors and Light (LT0). When Code 4=, there is a 48 Blank/Empty Section with Access Doors and Light (LT0). For sheet metal components that make up the Out-of-Airstream Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H. This Blank/Empty Access section may be installed on an RPS OR an RFS unit. Doors, Gasketing and Hardware Ref. Part Section Size No. Description 48 (C4= ) Qty. 48/4 (C4= ) Qty. N/S Door Assembly N/S Gasket- Horizontal N/S Gasket- Vertical N/S Door Sleeve Bearing N/S Door Catch N/S= Not Shown on diagram. Section Mounted Controls LT0, REC0, S0- Section Mounted Light LT0- Blank Access Section Light/S0- Blank Access Section Light Switch/REC0- Blank Access Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Light Switch- S Receptacle- REC Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

142 Section M- Condenser Section Notes Primary Codes that pertain: 09,, 43, 44, 47, 54, 68 Additional Codes that pertain: 7, 8, 4, 45 This section houses the Compressors, Condenser Coils, Condenser Control Box (RCS only), Pressure Controls Box (RPS/RDT only), and Fan Deck. RPS and RDT units do not have a control box in the Condenser section (all condenser controls are in the main unit Control Box). The Compressor high and low pressure controls as well as the fan pressure controls are always located in this section. RCS units have the pressure controls mounted on the control box Manifold (SpeedTrol Inverters and Line Reactors are in the Control Box). RPS and RDT units have the pressure controls as well as SpeedTrol Inverters and Line Reactors (if supplied) in a box mounted where the air handler and condensing unit attach. Code 09, unit voltage, affects Compressor Contactors and Motor Protectors (located in the Condenser Control Box for RCS units) as well as the Compressor selection. Code determines whether there is a MicroTech III Unit Controller present or if the unit is not provided with a factory installed controller. Code 43 determines if the Micro Channel Condenser Coils have Seal Tite Conduits and/or Coil Guards; and whether the Coils are coated. Code 44 shows the type of compressor selected. Code 44= R NORMALLY stands for units with ALL standard scroll compressors. For units with Inverter Compressors (Code 44= V, W) refer to form (Note that RPS, RDT074Ds are inverter compressor only units.) Starting in late 04, some units are built as specials with digital scroll compressors with Code 44= R AND Code 60= XX with digital scroll compressors listed as a special feature (refer to the drawing below for an example of Special Code String Text). Confirm the presence of a digital compressor BEFORE ordering to ensure that the correct part(s) are identified. Code 44= D also indicates the presence of digital compressors. Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47= ), OR SpeedTrol [Low Ambient operation] (Code 47= ). If Code 47= 3, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

143 Section M- Condenser Section Notes Code 54 indicates that Modulating Hot Gas Reheat was chosen. This option alters the number of Variable Speed Condenser motors and the Condenser Fan circuiting in the Main Control Box. Code 68 specifies the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at 0 SCCR (Code 68= 0, OR no entry). An entry with any other rating (Eg: Code 68=, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 7 determines whether the RCS control box has Ground Fault and/or Phase Failure capability. Code 8 determines if there is a unit powered Receptacle, and associated controls. Code 4 indicates Compressor capacity control. Code 45 determines the way the Compressor is mounted. If Code 45= Y the unit must be an RFS. The Condenser Coil Compartment, and the Compressor Compartment components are different for RPS and RCS units. All other aspects of the section (Fan Deck, Compressors, etc.) are identical. The Condenser Section is integral to the RPS unit, but is not Used on the RFS. An RCS unit is a condensing unit only. RCS units can either be used as a Stand Alone Condenser unit, OR used in conjunction with an RFS. For information specific to RCS Standalone Units (RCS D units when Code = *A), refer to RPL form Note that an RCS07D is a Standalone only unit and therefore is not included in this document. NOTE: This form is to be used for RCS units when Code = DOES NOT= *A. For RCS D units when Code = *A refer to form # Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 43

144 Section M- Condenser Section Condenser Fan Deck Assembly D Diagrams: Code 47=, Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail Fan # Fan # Fan # End of Unit Fan # Fan # End of Unit Fan # Fan # 045, 050, 060D Fan Deck Detail Fan # 05D Fan Deck Detail End of Unit CDF60 CDF50 Fan # 3 Fan # Fan # CDF5 CDF53 MOTOR GND WIRE 05 End of Unit Fan # 3 Fan # Fan # 063D Fan Deck Detail Fan # Fan # Fan # 3 Fan # 3 Fan # Fan # (063D shown) End of Unit 06, 06, 068D Fan Deck Detail Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 44

145 Section M- Condenser Section Condenser Fan Deck Assembly D Components Ref. Part Part Unit Size No. Description Number Condenser Coils Code 43= M* x 7 6/3 & Earlier " x 7" 7/3 thru 5/ x 7 6/4 & Later x 84 6/3 & Earlier " x 84" 7/3 thru 3/4 36 x 84 4/4 & Later x 84 6/3 & Earlier x 84 7/3 thru /4 46" x 84" 3/4 & Later Condenser Coils Code 43= T* x x x Condenser Coils, Coated Code 43= P* x 7 6/3 & Earlier x 7 7/3 thru 5/ x 7 /4 & Later x 84 9/3 & Earlier x 84 0/3 thru /4 36 x 84 /4 & Later x 84 9/3 & Earlier x 84 0/3 thru /4 46 x 84 /4 & Later Condenser Coils, Coated Code 43= U* x x x Condenser Fan Motor FanTrol/SpeedTrol 08/30/ FanTrol/SpeedTrol Condenser Fan Deck Code 47=, 55 Panel- Blank Top Panel Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit (RPS/RDT) N/S Vandal Guard Kit (RPS/RDT) N/S Vandal Guard Kit (RCS) N/S= Not shown on Diagram. Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications when Code 47= OR. 3 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 45

146 Section M- Condenser Section Condenser Fan Deck Assembly D Diagrams: Code 47=, Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail Fan # 3 End of Unit Fan # Fan # 070, 07D Fan Deck Detail Fan # Fan # Fan # Fan # 3 Fan # 4 Fan # 4 (075, 079D shown) Fan # End of Unit Fan # 3 5 Fan # Fan # Fan # 3 End of Unit 075, 079D Fan Deck Detail Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 46

147 Section M- Condenser Section Condenser Fan Deck Assembly 070D- 079D Components: Code 47=, Ref. Part Part Unit Size No. Description Number Condenser Coils Code 43= M* 5 3 x 84 6/3 & Earlier x 84 7/3 thru 5/ x 84 6/4 & Later x 84 6/3 & Earlier x 84 7/3 thru 3/4 36 x 84 4/4 & Later x 84 6/3 & Earlier x 84 7/3 thru /4 46 x 84 3/4 & Later Condenser Coils Code 43= T* 5 36 x x Condenser Coils, Coated Code 43= P* 3 x 84 7/3 & Earlier x 84 8/3 thru / x 84 /4 & Later x 84 9/3 & Earlier x 84 0/3 thru /4 36 x 84 /4 & Later x 84 9/3 & Earlier x 84 0/3 thru /4 46 x 84 /4 & Later Condenser Coils, Coated Code 43= U* 5 36 x x Condenser Fan Motor FanTrol/SpeedTrol 08/30/ FanTrol/SpeedTrol Condenser Fan Deck Code 47=, 55 Panel- Blank Top Panel Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit (RPS/RDT) N/S Vandal Guard Kit (RPS/RDT) N/S Vandal Guard Kit (RCS) N/S= Not shown on Diagram. Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications when Code 47= OR. 3 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 47

148 Section M- Condenser Section Quiet Fan Assembly Code 47= 3, 4 Ref. Part Part Unit Size No. Description Number Quiet Fan Assy. 08V V Panel, Blank NA NA 3 NA 3 3 Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor Mount, and Fan Top Panel are NOT available separately. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 48

149 Section M- Condenser Section Condenser Fan Deck Assembly Standard Compressors & Compressor Components Unit Size 045D: Code 44= R OR D 3 Side View Compressor Rail to Base Channel Mounting Detail (6 places) Compressor Rail or Compressor Mounting Channel Standard Cmpr. Units Circuit # & AND Digital Scroll Cmpr. Units: Circuit # 3 Ref. Part Part No. Description Number, Compressors (8/4 & Earlier) Compressors (7/4 & Earlier) Compressors (5/5 & Earlier) Heater- Crankcase (for early compressors) , Compressors (5/5 & Later) Compressors (/7 & Later) Compressors (6/5 & Later) Heater- Crankcase (for later compressors) Grommet Sleeve Screw Washer- Plain Washer- Lock Junction Box- Compressor Screw- Junction Box Gasket- Junction Box NOTE: Quantities listed are for the unit. Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. For units built during the transition, contact Daikin Applied with model and serial number information to ensure that the correct compressor is identified. 4 feet per junction box. 3 Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. For these units refer to the Digital Compressors & Components page at the end of this section. 08/30V Size 045 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 49

150 Section M- Condenser Section Condenser Fan Deck Assembly Standard Compressors & Compressor Components Unit Size 050, 05D: Code 44= R OR D 3 Side View Compressor Rail to Base Channel Mounting Detail (6 places) Compressor Rail or Compressor Mounting Channel Standard Cmpr. Units Circuit # & AND Digital Scroll Cmpr. Units: Circuit # 3 Size 050, 05 Ref. Part Part No. Description Number, Compressors Compressors Compressors Grommet Sleeve Screw Washer- Plain Washer- Lock Junction Box- Compressor Heater- Crankcase Screw- Junction Box Gasket- Junction Box NOTE: Quantities listed are for the unit. Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. 4 feet per junction box. 3 Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. For these units refer to the Digital Compressors & Components page at the end of this section. 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 50

151 Section M- Condenser Section Condenser Fan Deck Assembly Standard Compressors & Compressor Components Unit Size D: Code 44= R OR D Side View Compressor Rail to Base Channel Mounting Detail (6 places) Compressor Rail or Compressor Mounting Channel Standard Cmpr. Units Circuit # & AND Digital Scroll Cmpr. Units: Circuit # 3 Unit Size Ref. Part Part No. Description Number, Compressors 4/4 & Earlier Compressors 5/4 & Later Compressors 4/4 & Earlier Compressors 5/4 & Later Compressors 4/4 & Earlier Compressors 5/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Heater- Crankcase NOTE: Quantities listed are for the unit. Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. For these units refer to the Digital Compressors & Components page at the end of this section. 3 Unit sizes no longer in production as of /30V 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

152 Section M- Condenser Section Condenser Fan Deck Assembly Standard Compressors & Compressor Components Unit Size 068D: Code 44= R OR D 3 Side View Compressor Rail to Base Channel Mounting Detail (6 places) 07 Compressor Rail or Compressor Mounting Channel Standard Cmpr. Units Circuit # & AND Digital Scroll Cmpr. Units: Circuit # 3 Ref. Part Part No. Description Number, Compressors 4/4 & Earlier Compressors 5/4 & Later Compressors 4/4 & Earlier Compressors 5/4 & Later Compressors 4/4 & Earlier Compressors 5/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Heater- Crankcase NOTE: Quantities listed are for the unit. Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. For these units refer to the Digital Compressors & Components page at the end of this section. 08/30V Size 068 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

153 Section M- Condenser Section Condenser Fan Deck Assembly- Compressors & Compressor Components Unit Size D: Code 44= R, 3 or Side View Discharge Tubing 45 Gas Tubing Suction Tubing Circuit # Comp. # Comp. #3 Comp. #5 or or or or Circuit # Comp. # Comp. #4 Comp. #6 Compressor to Compressor Rail Mounting Detail 75 Circuit # or Circuit # Top View 0 Comp. # Comp. #3 Comp. #5 or or or Comp. # Comp. #4 Comp. #6 30 Compressor Rail to Base Channel Mounting Detail (8 places) Compressor Rail Compressor Mounting Channel Unit Size 070, Ref. Part Part No. Description Number, Compressors- Circuits #, Compressors- Circuits #, Compressors- Circuits #, Compressors- Circuits #, , Circuit # 079D Compressors- Circuits #, , Circuit # 079D Compressors- Circuits #, , Circuit # 079D Compressors- Circuit # 4/4 & Earlier Compressors- Circuit # 5/4 & Later Compressors- Circuit # 4/4 & Earlier Compressors- Circuit # 5/4 & Later Compressors- Circuit # 4/4 & Earlier Compressors- Circuit # 5/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Sight Glass- Gas Line Junction Box- Compressor Fitting- Rotolock Heater- Crankcase Screw- Junction Box Gasket- Junction Box Rail- Trio Compressor Mounting Spacer Screw Washer Quantities are for the unit. Each circuit has equal quantities of each part. 6 feet per junction box. 3 Note that Unit Size RPS/RDT074D uses Inverter Compressors only. Refer to form /30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 53

154 Section M- Condenser Section Digital Compressors & Components, Circuit # Code 44= R AND Code 60= XX OR Code 44= D, 3 Digital Scroll Compressor Units: Circuit # 08/30V Unit Size , 05 06, Ref. Part No. Number N/S N/S= Not shown on diagram. There are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes page at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. Compressors are factory mounted in TANDEM assemblies, but REPLACEMENT COMPRESSORS ARE AVAILABLE AS SINGLE COMPRESSORS ONLY as shown above. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit. When replacing a single compressor out of a Tandem assembly, the original piping is reused. 3 For unit sizes/voltages not shown contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. 08/30V 08/30V 08/30V Digital Scroll Compressor Units Crankcase Heaters 4 Part Number Unit Unit Compressor Compressor Compressor Compressor Size Voltage All N/A N/A N/A 050 All N/A N/A N/A 05 All N/A N/A N/A 06 All N/A N/A N/A 063 All N/A N/A N/A 068 All N/A N/A N/A N/A= Not available. 4 One Crankcase heater is used per compressor. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 54

155 Condenser Section Digital Compressors & Components, Circuit #, Unit Size 045D- 068D: Code 44= R AND Code 60= XX OR Code 44= D Digital Compressor Detail Compressor Rail to Base Channel Mounting Detail /30V Unit Size , 05 06, Ref. Part Part No. Description Number 0 Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # 3 0 Thermistor- Discharge (CDT) Compressor Mounting Kit Heater- Crankcase Heater- Crankcase Kit- Unloader Coil, 0V (SV7) NOTE: Quantities listed are for the unit. There are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes page at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. Compressors are factory mounted in TANDEM assemblies, but REPLACEMENT COMPRESSORS ARE AVAILABLE AS SINGLE COMPRESSORS ONLY as shown above. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit. When replacing a single compressor out of a Tandem assembly, the original piping is reused. 3 For unit sizes/voltages not shown contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 55

156 Section M- Condenser Section RCS Pressure Manifolds- 045D- 068D HP, HP, LP, LP, SPTRL Circuit # Circuit # SPTRL SPTRL SpeedTrol (Code 47=, 4) 35 HP HP 35 SpeedTrol (Code 47=, 4) LP LP FanTrol (Code 47=, 3) HP HP 35 FanTrol (Code 47=, 3) LP LP Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Harness- Switch SpeedTrol Pressure Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 56

157 Section M- Condenser Section RCS Pressure Manifolds D PC3, PC3, HP, HP, LP, LP, SPTRL Circuit # Circuit # SpeedTrol (Code 47=, 4) PC3 HP 35 SPTRL PC3 35 SPTRL HP SpeedTrol (Code 47=, 4) LP LP FanTrol (Code 47=, 3) PC3 HP HP PC3 FanTrol (Code 47=, 3) LP LP Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Harness- Switch SpeedTrol Pressure Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 57

158 Section M- Condenser Section RPS/RDT Pressure Controls Box- 045D- 068D: (03/03 & Earlier) AFD, AFD, LR, LR, LP, LP, HP, HP, TC, TC4 (Note: For RCS units, the SpeedTrol Inverters AFD, AFD and Line Reactors [ only] are located in the RCS control box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.) 44 HP SPTRL typ. AFD AFD 35 HP 46 LP SPTRL LP LR LR Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Harness- Switch SpeedTrol Pressure Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, AFD, Inverter 08/30V Inverter Inverter LR, Line Reactor only (Code 09= 37) N/S TC, 4 Temperature Control- FanTrol N/S= Not shown on diagram. On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 38, 39) in place of each of the SPTRL Switches. This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. 3 TC, 4 are only used when the unit has no temperature controls (Code = Y*). Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 58

159 Section M- Condenser Section RPS/RDT Pressure Controls Box D: (04/03 & Later) AFD, AFD, LR, LR, LP, LP, HP, HP, TC, TC4 (Note: For RCS units, the SpeedTrol Inverters AFD, AFD and Line Reactors [ only] are located in the RCS control box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.) See Factory Supplied Line Voltage Box Section 47 Ref. Sch. Part Part Qty. No. Sym. Description Number 33, 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, , 44 VFD, SpeedTrol VFD Code 54= YY 08/30V, HP , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V 93554, 3HP LR, Line Reactor only (Code 09= 37) On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 38, 39) in place of each of the SPTRL Switches. Note that ABB brand VFDs are offered as STANDARD. Confirm brand of VFD required BEFORE ordering or contact Daikin Applied. The replacement ABB brand VFD Keypad is p/n For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 59

160 Section M- Condenser Section RPS/RDT Pressure Controls Box- 070D- 079D: (03/03 & Earlier) AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 (Note: For RCS units, the SpeedTrol Inverters AFD, AFD and Line Reactors [ only] are located in the RCS control box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.) 44 HP PC SPTRL typ PC3 AFD AFD 35 HP 46 LP SPTRL LP LR LR Ref. Sch. Part Part Qty. No. Sym. Description Number 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, AFD, Inverter 08/30V Inverter Inverter LR, Line Reactor only (Code 09= 37) On FanTrol units, there is a valve core (Ref. # 38) and valve cap in place of each of the SPTRL switches. This Pressure Switch replaces a Switch with a lower pressure rating. P/N has the currently recommended pressure ratings. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 60

161 Section M- Condenser Section RPS/RDT Pressure Controls Box D: (04/03 & Later) AFD, AFD, LR, LR, LP, LP, HP, HP, PC3, PC3 (Note: For RCS units, the SpeedTrol Inverters AFD, AFD and Line Reactors [ only] are located in the RCS control box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.) See Factory Supplied Line Voltage Box Section Ref. Sch. Part Part Qty. No. Sym. Description Number 33, 34 LP, Switch- Low Pressure FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, HP, Switch- High Pressure PC3, 3 Switch- Fan Pressure SPTRL Switch- SpeedTrol Pressure Code 47=, Valve Core Valve Cap FanTrol Unit Code 47=, SpeedTrol Unit Code 47=, , 44 VFD, SpeedTrol VFD Code 54= YY 08/30V, HP , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V , HP , HP VFD SpeedTrol VFD Code 54= BM 08/30V 93554, 3HP On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 38, 39) in place of each of the SPTRL Switches. Note that ABB brand VFDs are offered as STANDARD. Confirm brand of VFD required BEFORE ordering or contact Daikin Applied. The replacement ABB brand VFD Keypad is p/n For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

162 Section M- Condenser Section Condenser Control Box (RCS Units Only) No Controls: Code = YM Diagrams RCS with no controls: Code = YM 03/03 & Earlier RCS with no controls: Code = YM 04/03 & Later For more information on RCS Standalone Units (Code = YA, A, A) refer to form # The above diagrams show typical Condenser Control Box layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

163 Section M- Condenser Section Condenser Control Box (RCS Units Only) MicroTech III Controls Code = LE, LF, BE, BF, EE, EF, SE, SF Diagrams RCS with MicroTech III Controls: 03/3 & Earlier RCS with MicroTech III Controls: 04/3 & Later The above diagrams show typical Condenser Control Box layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 63

164 Section M- Condenser Section RCS Control Box Components Sch. Part Part Qty. Sym. Description Number DCC DCC Digital Compressor Controller S Switch- System REC Receptacle Relays R Relay- Hi Pressure Reset R Relay- Hi Pressure Reset R5 Relay- Safety R6 Relay- Safety R7 Relay- Safety R8 Relay- Safety R Relay- Condenser Fan (MTIII) R3-36 Relay- Compressor Staging var. Ground Fault Protection GFR4 Ground Fault Relay- SPDT Code 7= YG, YC GFS4 Ground Fault Sensor Code 7= YG, YC Phase Voltage Monitor (PVM) Code 7= YP, YC PVM4 Phase Voltage Monitor 08/30/ Units (/6 & Earlier) 000 Units (/6 & Earlier) /30/ Units (/7 & Later) Units (/7 & Later) Socket, PVM (/7 & Later) PL5-30 Plugs- Pin /comp Terminal Blocks TB,3,5,6,8 Terminal Block var. TB35 Terminal Block Assy TB36 Terminal Block Assy Power Block- Main Code = P PB4 Power Block, Main 75A A, 40A Contactors M- 6 Contactor- Compressors 3 M- 4 Contactor- Fan Motors 3 Manual Motor Protector MMP- 6 MMP- Compressor 3 MMP- 3 MMP- Fan Motors 3 Time Delays TD, Time Delays, Compr. Lockout 4 TD9 Time Delay, Coil Splitter Part number is for one section. Quantity of sections varies with unit options. Ground Terminal is p/n Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. 3 These components are installed in the RCS unit Condenser Control Box however, Compressor and Condenser Fan Motor Contactors and associated parts are detailed in the Main Control Box Section (Section N). 4 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n The ADJUSTABLE version of this relay could also have been supplied: p/n Confirm which relay is required BEFORE ordering. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 64

165 Disconnect Switches 03/3 & Earlier Section M- Condenser Section RCS Control Box Components, Continued Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS4 Disconnect Switch- Condenser Control Box Switch- 00A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS4 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. For DSs larger than 400A, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Disconnect Switches 04/3 & Later Ref. Part Part Voltage No. Description Number 08V 30V Disconnect Switch DS4 Disconnect Switch- Condenser Control Box Switch- 00A Handle 9340 Shaft Switch- 50A Handle 9340 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS4 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. For DSs larger than 400A, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 3 This shaft is 4.5 OAL and is designed to be cut to length in the field. 4 This shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 65

166 Section M- Condenser Section Factory Supplied Line Voltage Box- Powered Receptacle and Lights T6, DS6, FU6A, FU6B, FU6C: Code 8= U***, V*** OR Code 3= ***F* 03/3 & Earlier T6 DS6 8 L L L3 9 3 FU6C FU6B FU6A T T T3 Voltage Ref. Sch. Part Part No. Sym. Description Number T6 Transformer KVA Transformer KVA Transformer KVA DS6 Disconnect Switch 30A/600V FU6A,B Fuse 0A/600V Fuse 0A/600V Fuse 8A/600V FU6C Fuse 0A/600V V 30V 0 04/3 & Later 0 TB7 DS6 Main Control Box Pressure Controls Box ( D shown) Voltage Ref. Sch. Part Part No. Sym. Description Number 0 DS6 Fuse Holder/Circuit Protector P, 30A, 600V FU6A, B Fuse 0A/600V Fuse 0A/600V Fuse 8A/600V TB7 Terminal, x Green Terminal Block End Plate Terminal, x Grey Terminal Block End Stop Grey T6 Transformer KVA Transformer KVA Transformer KVA Terminal Cover Kit FU6C Fuse 0A/600V V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 66

167 Section N- Main Control Box Notes Primary Codes that pertain: 08, 09,,, 3, 4, 5, 6, 7, 8, 3 (Mid 0 & Later), 68 Additional Codes that pertain: 04, 9, 0,, 7, 30, 3, 34, 35, 40, 47 The Main Control Box applies to the RPS, RFS, and RDT. The RCS has its own Controls that are detailed in Section M. The Main Control Box is comprised of three primary parts The Deadfront Door with the Keypad, the Control Panel, and the Power Panel. In March and April of 03, the Main Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and VFD circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable. For units built and shipped during the transition, confirm which design was used, or contact Daikin Applied to ensure that the correct part(s) are identified. Code 08 determines where the Control Box is installed- D indicates the discharge plenum (RPS, RFS), F indicates the supply air section (RDT). Code 9 is the unit voltage and affects Transformers, Fan Overloads/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Power/Terminal Block OR a through-the-door Disconnect. Code determines which type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, OR none) and whether the unit uses Discharge Temperature, Space Control, OR Zone control. There is an MCB and separate Expansion Boards (Condenser, Electric Heat, Energy Recovery) in the Control Box. Units may also have no unit controls (Code = YM, YC) in which case the Main Control Box has no MCB OR Expansion boards, but instead has a set of relays. RCS Standalone Units (units that are designed to be used as a standalone condensing unit, OR intended to be hooked to a separate Air Handler unit) have additional codes which add Transformers. For RCS Standalone Unit specific information, (Code = *A), refer to RPL form # Code 3 determines the presence of Duct and/or Space Sensors. Codes 4 and 5 determine the Supply and Return Fan Inverter characteristics. Code 6 determines the presence of Smoke Detectors. Code 7 AND/OR 3 (Mid 0 & Later) determine miscellaneous electrical options including whether the unit has a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc. Code 68 specifies the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at 0 SCCR (Code 68= 0, OR no entry). An entry with any other rating (Eg: Code 68=, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 8 indicates whether a unit has a Remote Keypad Display and/or a unit mounted Receptacle. Codes 9, 0 and are return air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc, have an impact on Contactors, Motor Protectors, Fuses, and Duct Sensors. Code 7 determines the draw through section, and can impact the Cooling Circuit Relays. Code 3 determines horsepower for the Supply Fan Motor which, like the Return Air Motor, will affect Contactors, Motor Protectors, Fuses, Overloads, etc. Codes 04, 30, (RDT) 34, and 35 determine the BlowThru section, and the heat type, which will impact the Transformers, heat circuit Relays, and cooling circuit Relays. Code 40 determines if there is a VAV/Discharge Damper and associated Relay. Code 47 determines if the unit has SpeedTrol fan control and affects the condenser fan fusing, and whether there are SpeedTrol Inverters and associated components. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 67

168 Section N- Main Control Box Control Box Component Label Diagram Note that starting in late 00 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 68

169 Section N- Main Control Box Control Panel - No Controls (Code = YM, YC) Diagrams Left Side Door R R R 0 R R 4 5 R R 8 9 R 63 R 5. R 6. R 7. R 8. R 9 R 0 R 67 R 68 R 69 R 70 R R R 7 3. R 4. TD TD DHL See Power Panel T4 T Left Side Door Detail Switches Detail HS S CS CS S4 S7 The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 69

170 Sch. Part Part Qty. Sym. Description Number Switches- Control HS Switch- Electric Heat Shutdown Code 04= E CS, Switch- Control S Switch- System On/Off Gas Heat Units Code 04= A Elec.,Steam,HW, No Heat Code 04= E, S, W, Y S4 Switch- Inverter Bypass On/Off S7 Switch- Local On/Auto/Off Relays R Relay- Hi Pressure Reset R Relay- Hi Pressure Reset R5. Relay- Safety R6. Relay- Safety R7. Relay- Safety R8. Relay- Safety R9 Relay- Compressor Lockout R0 Relay- Compressor Lockout R Relay- SpeedTrol Inverter Code 47=, R3. Relay- Safety R4. Relay- Safety R7 Relay- SpeedTrol Inverter Code 47=, R8 Relay- Cooling Failure Indicator R9 Relay- Cooling Failure Indicator R0 Relay- Steam, Hot Water Heat Code 04= S, W Relay- Electric Heat Code 04= E Relay- Gas Heat Code 04= A Units w/gas Actuator Code = YC Hi Turn Down Burner Code 34 (5th digit)= H, T, U Modulating Burner Code 34 (5th digit)= E, R, S Units w/float Control Code = YM Hi Turn Down Burner Code 34 (5th digit)= H, T, U Modulating Burner Code 34(5th digit)= E, R, S R4 Relay- Gas Heat Alarm Code 04= A R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R63 Relay- Specials R67 Section N- Main Control Box Control Panel - No Controls (Code = YM, YC) Components Relay- Supply Fan Enable With Inverter Bypass Code 4= No Inverter Bypass Code 4= R68 Relay- Return Fan Enable R69 Relay- Inverter Bypass VAV Interlock Code 4= R70 Relay- Specials Duct Hi Limit Switch DHL Duct Hi Limit Switch Transformers- Controls T Transformer- Control Input 5-4V T4 Transformer- Exhaust Damper Actuator 5- VDC All R0 options are detailed here but for units with gas heat, the R0 is located in the gas heat control box (see section G). Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 70

171 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (03/03 & Earlier) Code = *E, *F, *W- Diagram See Power Panel The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

172 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (03/03 & Earlier) Code = *E, *F, *W- Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad/Interface Display Expansion Module EXP A Expansion Module- Condenser/ Energy Recovery EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Communication Card COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge Code = LE, LW LonWorks- Constant Volume Code = LF Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/0A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer Kit- Duct Sensor (9/ & Earlier) 3, Pressure Transducer- Duct Sensor (0/ thru 3/3) Pressure Transducer Kit- Space Sensor (9/ & Earlier) 3, Pressure Transducer- Space Sensor (0/ thru 3/3) Not Shown on diagram. Quantity varies depending upon unit size and options selected. 3 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. 4 As of 09/ the original Pressure Transducer is no longer available. The Transducer Kit includes Transducer, Dinrail, Resistor, Sampling Tube, and installation Instructions. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

173 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (03/03 & Earlier) Code = *E, *F, *W- Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- SpeedTrol inverter AFD R Relay- Condenser Fan R3 Relay- Condenser Fan R4 Relay- Condenser Fan R7 Relay- SpeedTrol inverter AFD R0 Relay- Heat R Relay- Gas Heat R4 Relay- Gas Heat Alarm R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R6 Relay- Iso Damper- Open/Close R8 Relay- Isolation Damper Safety R45 Relay- UV Lights R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y R8 Relay- Inverter Reset 4P/6A/4V R8 Relay- Inverter Reset 4P/6A/4V R83 Relay- Smoke 4P/6A/4V R84 Relay- Smoke 4P/6A/4V R85 Relay- Smoke 4P/6A/4V R86 Relay- Smoke 4P/6A/4V R87 Relay- Smoke 4P/6A/4V R88 Relay- Smoke 4P/6A/4V Time Delays TD0 Time Delay- Return Air Fan Terminal Block TB Terminal Block Sensors SHS Sensor, Humidity Duct Mounted Sensor, Humidity Wall Mounted ZNT Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only- Code = BF, LF, EF, SF. 3 Not Shown on diagram. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 73

174 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (04/03 & Later) Code = *E, *F, *W- Diagram PL - PL43 Plugs See Power Panel See Power Panel The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 74

175 Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (04/03 & Later) Code = *E, *F, *W- Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) Connector, Extension I/O Direct Connect Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole MicroTech III Remote Unit Keypad/Interface Display DCC Digital Compressor Controller Expansion Module EXP A Expansion Module- Condenser/ Energy Recovery EXP B Expansion Module- Heat EXP D Expansion Module- Specials Terminal Block, EXP- Pole /board Terminal Block, EXP- 3 Pole /board Terminal Block, EXP- 7 Pole /board Terminal Block, EXP- 8 Pole /board Hot Gas Reheat RHB, Hot Gas Reheat Interface Boards Code 54= BM Communication Card COM Bacnet- MSTP Code = BE, BF, BW Bacnet- IP Code = EE, EF, EW LonWorks- Discharge Code = LE, LW LonWorks- Constant Volume Code = LF Resistors RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6,7,8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown Code 04= E S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/0A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer- Duct Sensor Pressure Transducer- Space Sensor Snubber, Pressure Transducer (optional; field installed) 90870, Not Shown on diagram. Quantity varies depending upon unit size and options selected. 3 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 75

176 C F Section N- Main Control Box Control Panel- MicroTech III Units with Controller: (04/03 & Later) Code = *E, *F, *W- Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- SpeedTrol inverter VFD R Relay- Condenser Fan R3 Relay- Condenser Fan R4 Relay- Condenser Fan R7 Relay- SpeedTrol inverter VFD R0 Relay- Heat R Relay- Gas Heat R4 Relay- Gas Heat Alarm R5 Relay- Gas Heat, Start Supply Fan Inverter Code 4=,,3,5,6, R6 Relay- Iso Damper- Open/Close R8 Relay- Isolation Damper Safety R45 Relay- UV Lights R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct Sensors Code 3= Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y R8 Relay- Inverter Reset 4P/6A/4V R8 Relay- Inverter Reset 4P/6A/4V R83 Relay- Smoke 4P/6A/4V R84 Relay- Smoke 4P/6A/4V R85 Relay- Smoke 4P/6A/4V R86 Relay- Smoke 4P/6A/4V R87 Relay- Smoke 4P/6A/4V R88 Relay- Smoke 4P/6A/4V Time Delays TD0 Time Delay- Return Air Fan Terminal Block TB Terminal Block Sensors SHS Sensor, Humidity Duct Mounted 3 /6 & Earlier Sensor, Humidity Duct Mounted 3 /7 & Later Sensor, Humidity Wall Mounted ZNT Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only (Code = *F). 3 Not Shown on diagram. 4 In late 03, Digital Room Sensor p/n was added as the preferred option. The other Zone Temperature Sensors are available as options. For positive p/n identification, refer to the drawings below. ZNT Sensor ZNT Sensor 3770 ZNT Sensor 3780 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 76

177 Section N- Main Control Box Power Panel: (03/03 & Earlier) Diagrams See Control Panel See Control Panel See Control Panel PL - PL43 Plugs The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 77

178 Section N- Main Control Box Power Panel: (03/03 & Earlier) Components Power Panel- Terminal Blocks, T Transformer & Fusing Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB,3,4,7 Terminal Block Transformer- Main 3 T Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= Units with UV Lights Code 7 [nd digit]= FC Fuse- T Transformer Fuse- T Transformer Fuse- T Transformer Varies depending on unit options. Part number is for one individual section. Ground block is p/n When required TB,3,4 OR 7 use jumpers p/n ( pole), (3 pole), (4 pole), (5 pole). 3 All T transformers also use a fuse puller kit p/n & a cover kit p/n Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; 04753= Non- Gas Heat Units with no UV lights. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 78

179 Sch. Part Part Voltage Sym. Description Number 08V 30V Fuses, continued F,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor Code 04= A F5 Fuse- UV Lights Code 7 [nd digit]= Phase Voltage Code 7 [nd digit]= P, A, C, D, H, J, K PVM, Phase Voltage Monitor 000 Phase Voltage Monitor 000 Ground Fault Code 7 [nd digit]= G, B, C, D, K GFR, Ground Fault Relay- SPDT GFS, Ground Fault Sensor Power Blocks PB, PB Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block PB Section N- Main Control Box Power Panel: (03/03 & Earlier) Components, Continued Power Panel- Fusing, Phase Protection, Ground Fault, Power Blocks Lug- 840A Block Power Block- Power Distribution Power Block- 40A Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat KW Electric Heat , 40 KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. PB is installed when Code = Q. These power blocks are used on RPS and RDT units. RFS units use the following: 75A p/n Lug p/n ; 30A p/n Lug p/n ; 40A p/n Lug ; 760A p/n Lug p/n Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 79

180 Power Panel- Power Blocks continued, Receptacle, Disconnect Switch DS Sch. Part Part Voltage Sym. Description Number 08V 30V Power Blocks, continued PB0 Power Block- Supply Fan Code 5= F PB0 Power Block- Return Fan Code 5= F Receptacle REC Receptacle Disconnect Switch DS Disconnect Switch- Main Gas, Steam, HW, No Heat (C04= A, S, W, Y) units Switch- 00A Handle Kit Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 600A,, 3, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. The 600A Switch listed is used on units with one Disconnect OR two Disconnects EH/balance of unit (Code = A, B). 3 If unit has two Disconnects where the second Disconnect controls the fans (Code = C) OR 3 Disconnects (Code = D) then use Switch p/n , Handle Kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper installation. Section N- Main Control Box Power Panel: (03/03 & Earlier) Components, Continued Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 80

181 Section N- Main Control Box Power Panel: (03/03 & Earlier) Components, Continued Power Panel- Disconnect Switch DS continued Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch, continued DS Disconnect Switch- Main Electric Heat (Code 04= E) units Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Switch- 600A,, 3, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. The 600A Switch listed is used on units with one Disconnect OR two Disconnects EH/balance of unit (Code = A, B). 3 If unit has two Disconnects where the second Disconnect controls the fans (Code = C) OR 3 Disconnects (Code = D) then use Switch p/n , Handle Kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper installation. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

182 Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch, continued DS Disconnect Switch- SAF/RAF Code = C, D Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Circuit Breakers CB0 CB0 Section N- Main Control Box Power Panel: (03/03 & Earlier) Components, Continued Power Panel- Disconnect Switch DS, Circuit Breakers CB0, 0 Circuit Breaker Circuit Breaker- Return Fan Motor HP=, Motor HP=, 3, 5, 7.5, Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= 0, Motor HP= Motor HP= Motor HP= 5, Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

183 Power Panel- Circuit Breakers CB0, 0 continued, Plugs Sch. Part Part Voltage Sym. Description Number 08V 30V Circuit Breakers, Continued CB0 CB0 Circuit Breaker Circuit Breaker- Return Fan Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= CB60 Circuit Breaker- Heat Recovery Wheel Code 4= F Circuit Breaker- Heat Recovery Wheel Code 4= F PL- 43 Plugs Pin Plug varies varies varies varies 5 6 Pin Plug varies varies varies varies 6 Pin Plug varies varies varies varies 7 3 Pin Cap Kit varies varies varies varies 8 6 Pin Cap Kit varies varies varies varies 9 9 Pin Cap Kit varies varies varies varies 0 5 Pin Cap Kit varies varies varies varies 3 All possible Plugs used are listed. Check actual unit to verify which Plug is required. 4 Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 5 Used with Strain Relief (p/n ) & 6 pin Cap Kit (p/n ). Used for PL0, PL. 6 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 7 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 8 Used for PL9, PL0. 9 Used for PL8, PL9, PL35, PL36, PL43. 0 Used for PL7, PL8. Section N- Main Control Box Power Panel: (03/03 & Earlier) Components, Continued Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 83

184 Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Diagrams Front Mtd. Contact 3E Link 3B 3 MMP Contactor MMP 3 3E Contactor Front Mounted Aux. Contact MMP 3 Lug Trip Indicator Alarm Contactor 3F 3G MMP0 & M0 Link Detail MMP0 & M0 Link Detail, 3, 5, 7.5 HP Motors- All Voltages 0 HP Motor- 30/460/ 5, 0 HP Motor- 460/ 5, 30 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 0HP Motor- 08V 5HP Motor- 08/30V 0 HP Motors- 08/30V 5 HP Motors- 30/ 30 HP Motors- 40 HP Motors- 460/ 50 HP Motors- 460/ MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 08V 30 HP Motors- 30V NOTE: The diagrams show all possible parts. Not every part shown applies to every unit size/voltage combination. Lug 3G 3G Lug MMP 3 3 MMP Trip Ind. Interlock 3F 3F Trip Ind. Interlock Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 30 HP Motors- 08V 40 HP Motors- 08/30V 50 HP Motors- 30VV MMP0 & M0 Link Detail 50 HP Motors- 08V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 84

185 HP Motor- Code = G*Y Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply and Return Fan Contactors Components Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Return Fan MMP0 MMP- Return Fan MMP- Return Fan MMP- Return Fan MMP- Return Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 3 HP Motor- Code OR 3= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 5 HP Motor- Code OR 3= J*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 85

186 7.5 HP Motor- Code OR 3= K*Y Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply and Return Fan Contactors Components, Continued Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 0 HP Motor- Code OR 3= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 5 HP Motor- Code OR 3= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 86

187 0 HP Motor- Code OR 3= N*Y Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply and Return Fan Contactors Components, Continued Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC V 30V 5 HP Motor- Code OR 3= P*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 87

188 30 HP Motor- Code OR 3= Q*Y Section N- Main Control Box Power Panel: (03/03 & Earlier) Supply and Return Fan Contactors Components, Continued Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0,0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Front Mtd. Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) HP Motor- Code 3= R*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 Motor Protector- Supply Fan Motor Protector- Supply Fan E Front Mtd. Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 ring terminals. 08V 08V 30V 30V 50 HP Motor- Code 3= S*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 Motor Protector- Supply Fan Motor Protector- Supply Fan E Front Mtd. Aux. Contact- NO OR NC F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 ring terminals. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 88

189 Section N- Main Control Box Power Panel Compressor MMP thru 4 and Contactor M thru 4: (03/03 & Earlier) Unit Size 045D Front Mounted Contact 3E MMP 3 Front Mounted Contact 3E 3 MMP Link 3B Contactor Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 4 & M- 4 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 50A M- 4 Contactor- Compressor 5A Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compressor Manual Motor Protector- Compressor Manual Motor Protector- Compressor B Link E Front Mtd. Aux. Contact- NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. 08/30V 045 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 89

190 Section N- Main Control Box Power Panel Compressor MMP thru 4 and Contactor M thru 4: (03/03 & Earlier) Unit Sizes 050, 05D Front Mounted Contact 3E MMP 3 Front Mounted Contact 3E 3 MMP Link 3B Contactor Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 4 & M- 4 Contactor Link Detail 460/ 050, 05 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A M- 4 Contactor- Compressor 5A Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compressor Manual Motor Protector- Compressor Manual Motor Protector- Compressor B Link E Front Mtd. Aux. Contact- NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 90

191 Section N- Main Control Box Power Panel Compressor MMP thru 4 and Contactor M thru 4: (03/03 & Earlier) Unit Sizes D Front Mounted Contact 3E MMP 3 Front Mounted Contact 3E 3 MMP Contactor Link 3B Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 4 & M- 4 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A M- 4 Contactor- Compressor 3A Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr B Link E Front Mtd. Aux. Contact- NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

192 Section N- Main Control Box Power Panel Compressor MMP thru 4 and Contactor M thru 4: (03/03 & Earlier) Unit Size 068D Lug Kit MMP 3 3F Front Mounted Contact 3E Front Mounted Contact 3E MMP 3 Contactor Front Mounted Contact A MMP- 4 & M- 4 Contactor Link Detail 08V Contactor MMP- 4 & M- 4 Contactor Link Detail 30/460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 80A M- 4 Contactor- Compressor 65A M- 4 Contactor- Compressor 40A Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr E Front Mtd. Aux. Contact- NO OR NC Front Mounted Contact- NO F Lug Kit (3 lugs per kit) In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

193 Section N- Main Control Box Power Panel Compressor MMP thru 6 and Contactor M thru 6: (03/03 & Earlier) Unit Sizes 070, 07D Front Mounted Contact 3E MMP 3 Front Mounted Contact 3E 3 MMP Contactor Link 3B Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail 460/ 070, 07 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 50A M- 6 Contactor- Compressor 5A Compressor MMP s & Parts 3 MMP- 6 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr B Link E Front Mtd. Aux. Contact- NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 93

194 Section N- Main Control Box Power Panel Compressor MMP thru 6 and Contactor M thru 6: (03/03 & Earlier) Unit Size 075D Front Mounted Contact 3E MMP 3 Front Mounted Contact 3E 3 MMP Link 3B Contactor B Spacer Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 65A Contactor- Compressor 5A B Spacer Compressor MMP s & Parts 3 MMP- 6 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr B Link E Front Mtd. Aux. Contact- NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. Note that Unit Size 074D uses Inverter Compressors only. Refer to form /30V 075 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 94

195 Section N- Main Control Box Power Panel Compressor MMP thru 6 and Contactor M thru 6: (03/03 & Earlier) Unit Size 079D Front Mounted Contact 3E MMP 3 Front Mounted Contact 3E 3 MMP Link 3B Contactor B Spacer Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 6 & M- 6 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor, Cir. # 65A Contactor- Compressor, Cir. # 5A M, 4, 6 Contactor- Compressor, Cir. # 65A Contactor- Compressor, Cir. # 5A B Spacer Compressor MMP s & Parts 3 MMP, 3, 5 Manual Motor Protector- Compr., Cir. # Manual Motor Protector- Compr., Cir. # Manual Motor Protector- Compr., Cir. # MMP, 4, 6 Manual Motor Protector- Compr., Cir. # Manual Motor Protector- Compr., Cir. # Manual Motor Protector- Compr., Cir. # B Link E Front Mtd. Aux. Contact- NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. 08/30V 079 Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 95

196 Section N- Main Control Box Power Panel Condenser Fan Contactors, MMPs, & Fusing FanTrol Units Code 47=, 3: (03/03 & Earlier) MMP 8 8 MMP Link 8B 8B Link 7 One Contactor Arrangement 7A Spacer Contactor 8C Bus Bar Contactor 7 7A Spacer Two Contactor Arrangement Ref. Sch. Part Part No. Symbol Description Number Cond. Fan Contactors 7 M- 4 Contactor- Cond. Fan A Spacer Fan MMP s & Parts 8 MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP C Bus Bar /30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 96

197 Section N- Main Control Box Power Panel Condenser Fan Contactors, MMPs, & Fusing, Continued SpeedTrol Units Code 47=, 4: (03/03 & Earlier) Components MMP & Contactors Detail SpeedTrol Fuses MMP 8 Adapter 9C 8B Link 7 8 MMP 7A Spacer Contactor Link 8B 8C Bus Bar Contactor 7 7A Spacer Puller 9B Fuse 9A 9 Fuse Block One Contactor Arrangement Two Contactor Arrangement F OR F Ref. Sch. Part Part No. Symbol Description Number Fan Contactor & Spacer 7 M- 4 M- 4 Contactor A Spacer Fan MMP s & Parts 8 MMP Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector MMP Manual Motor Protector Manual Motor Protector MMP3 Manual Motor Protector Manual Motor Protector Manual Motor Protector B Link- MMP C Bus Bar SpeedTrol Fusing 9 F, Fuse Block B Fuse Cover/Puller A F, Fuse- SpeedTrol Fuse- SpeedTrol Fuse- SpeedTrol C DIN Rail Adapter Contact Daikin Applied with model and serial number information so that the correct part can be identified 08/30V 08/30V 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 97

198 Section N- Main Control Box Power Panel Heat Recovery Wheel MMP60 and Contactor M60: (03/03 & Earlier) Components 8 MMP Link 8B 7 Contactor Unit Voltage Ref. Sch. Part Part No. Sym. Description Number Heat Wheel Contactor 7 M60 Contactor Heat Wheel MMP s & Parts 8 MMP60 Manual Motor Protector Manual Motor Protector B Link- MMP /30V Units With No Frost Protection (Code 4= Y). Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 98

199 Section N- Main Control Box Power Panel: (04/03 & Later) Diagrams See Control Panel See Control Panel PL - PL43 Plugs The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 99

200 Section N- Main Control Box Power Panel: (04/03 & Later) Components Power Panel- Terminal Blocks, T Transformer & Fusing Sch. Part Part Voltage Sym. Description Number 08V 30V Terminal Blocks TB, 3, 4,7 Terminal Block Transformer- Main Control & Fusing T Transformer Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Code 3= Y**** ALL Sizes 000VA ALL Sizes 000VA ALL Sizes 000VA Units with UV Lights Code 3= U**** ALL Sizes 500VA ALL Sizes 500VA ALL Sizes 500VA Gas Heat Code 04= A Units without UV Lights Code 3= Y**** ALL Sizes 500VA ALL Sizes 500VA ALL Sizes 500VA Units with UV Lights Code 3= U**** ALL Sizes 000VA ALL Sizes 000VA ALL Sizes 000VA N/S Cover Kit, Terminal N/S Cover Kit, Fuseholder Fuses- T Transformer FUA, B Fuse- T Transformer, Primary FUC Fuse- T Transformer, Secondary N/S= Not shown on diagram. Varies depending on unit options. Part number is for one individual section. Ground block is p/n When required TB, 3, 4, 7 use Jumper p/n ( pole), (3 pole), (4 pole), (5 pole). Contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 00

201 Section N- Main Control Box Power Panel: (04/03 & Later) Components, Continued Power Panel- Fusing, Phase Protection, Ground Fault, Power Blocks Sch. Part Part Voltage Sym. Description Number 08V 30V Fuses F,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA transformer F3 Fuse- Blower Motor Code 04= A F5 Fuse- UV Lights Code 7 [nd digit]= Phase Voltage Code 7 [nd digit]= P, A, C, D, H, J, K PVM, Phase Voltage Monitor (/6 & Earlier) Phase Voltage Monitor (/6 & Earlier) Phase Voltage Monitor (/7 & Later) Phase Voltage Monitor (/7 & Later) Socket, PVM (/7 & Later) Ground Fault Code 7 [nd digit]= G, B, C, D, K GFR, Ground Fault Relay- SPDT GFS, Ground Fault Sensor Power Blocks PB, PB Power Block- Main Code = P, Q Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/30V- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 40A Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution Code 04= E 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat KW Electric Heat , 40 KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure the the correct part(s) are identified. PB is installed when Code = Q. These power blocks are used on RPS and RDT units. RFS units use the following: 75A p/n Lug p/n ; 30A p/n Lug p/n ; 40A p/n Lug ; 760A p/n Lug p/n For units built /7 contact Daikin Applied with model and serial number to ensure correct part(s) are identified. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

202 Section N- Main Control Box Power Panel: (04/03 & Later) Components, Continued Power Panel- Power Blocks, continued, Receptacle, Plugs Sch. Part Part Voltage Sym. Description Number 08V 30V Power Blocks, continued PB0 Power Block- Supply Fan Code 5= F PB0 Power Block- Return Fan Code 5= F Receptacle REC Receptacle PL- 43 Plugs 4 Pin Plug varies varies varies varies 3 6 Pin Plug varies varies varies varies 4 Pin Plug varies varies varies varies 5 3 Pin Cap Kit varies varies varies varies 6 6 Pin Cap Kit varies varies varies varies 7 9 Pin Cap Kit varies varies varies varies 8 5 Pin Cap Kit varies varies varies varies All possible Plugs used are listed. Check actual unit to verify which Plug is required. Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 3 Used with strain relief (p/n ) & 6 pin cap kit (p/n ). Used for PL0, PL. 4 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 5 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

203 Power Panel- Disconnect Switch DS, Section N- Main Control Box Power Panel: (04/03 & Later) Components, Continued Sch. Part Part Voltage Sym. Description Number 08V 30V Disconnect Switch DS, Disconnect Switch- Main, RAF & SAF Switch- 00A Handle 9340 Shaft Switch- 50A Handle 9340 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Switch- 800A Handle Mechanism Shaft Lugs Switch- 000A Handle Mechanism Shaft Lugs Disconnects are sized according to various unit specifications. Check installed switch to verify the correct Disconnect size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. This Shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This Shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 03

204 Section N- Main Control Box Power Panel: (04/03 & Later) Supply MMP0 & M0 Fan Contactor Return MMP0 & M0 Fan Contactor Diagrams Phase Barrier Front Mtd. Aux. Contact 3E MMP 3 Phase Barrier Front Mtd. Aux. Contact 3E MMP 3 MMP 3 Link 3B Contactor Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact 3B Link Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail HP Motors- All Voltages 3, 5 HP Motors- 460/ 7.5 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 3, 5 HP Motors- 08/30V 7.5 HP Motors- 08/30/ 0 HP Motors- All Voltages 5, 0 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 08/30/ 0, 40 HP Motors- 5, 30 HP Motor- 460/ NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Phase Barrier 3E Front Mtd. Aux. Contact MMP 3 3 Circuit Breaker (not shown) Link 3B Contactor Terminal Block 4A Contactor 4 Overload MMP0 & M0 Link Detail MMP0 & M0 Link Detail 0, 5, 30 HP Motors- 08/30V 40 HP Motors- 50 HP Motors- 460/ MMP0 & M0 Link Detail 40, 50 HP Motors- 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 04

205 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components Horsepower Motor- Code = G*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Return Fan 9A Contactor- Return Fan 7A Front Mtd. Aux. Contact- NO AND NC MMP0 MMP- Return Fan 5.5-8A MMP- Return Fan A MMP- Return Fan.- 3.A MMP- Return Fan.8-.5A B Link E Phase Barrier N/S CB0 Circuit Breaker- Return Fan 5A FB0 Fuseblock- Return Fan Fuse- Return Fan 0A Fuse- Return Fan 9A Fuse- Return Fan 4A Fuse Cover/Puller- Return Fan N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V 3 HP Motor- Code OR 3= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 7A Fuse Cover/Puller N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 05

206 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code OR 3= J*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 5A Fuse- Supply OR Return Fan 0A Fuse- Supply OR Return Fan 0A Fuse Cover/Puller N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V 7.5 HP Motor- Code OR 3= K*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 35A Fuse - Supply OR Return Fan 5A Fuse Cover Fuse Cover/Puller N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 06

207 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code OR 3= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link E Phase Barrier N/S AFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 50A Fuse- Supply OR Return Fan 45A Fuse- Supply OR Return Fan 0A Fuse Cover- Supply OR Return Fan Fuse Cover/Puller- Supply Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 07

208 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 5 HP Motor- Code OR 3= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link E Phase Barrier N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 0A FB0, 0 Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 70A Fuse - Supply OR Return Fan 60A Fuse - Supply OR Return Fan 30A Fuse Cover Fuse Cover Fuse Cover/Puller N/S= Not Shown on Diagram. pc. PER Fuse. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 08

209 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 0 HP Motor- Code OR 3= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Spacer B Link Link Link E Phase Barrier Phase Barrier N/S AFD0, 0 VFD- Supply OR Return Fan N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 70A Circuit Breaker- Supply OR Return Fan 60A Circuit Breaker- Supply OR Return Fan 30A FB0, 0 Fuseblock- Supply OR Return Fan Fuse- Supply OR Return Fan 40A Fuse Cover- Supply OR Return Fan N/S= Not Shown on Diagram. Refer to the Inverter Section for VFD p/ns. Reference Code 5 for Inverter brand supplied. 08V 30V 5 HP Motor- Code OR 3= P*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link Link Link E Phase Barrier N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 90A Circuit Breaker- Supply OR Return Fan 80A Circuit Breaker- Supply OR Return Fan 40A FB0, 0 Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 50A Fuse Cover N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 09

210 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 30 HP Motor- Code OR 3= Q*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Front Mtd. Aux. Contact- NO AND NC MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link Link Link E Phase Barrier N/S CB0, 0 Circuit Breaker- Supply OR Return Fan 5A Circuit Breaker- Supply OR Return Fan 90A Circuit Breaker- Supply OR Return Fan 40A FB0, 0 Fuseblock- Supply OR Return Fan Fuse - Supply OR Return Fan 60A Fuse Cover N/S= Not Shown on Diagram. 08V 30V 40 HP Motor- Code 3= R*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 5A Contactor- Supply Fan 65A Contactor- Supply Fan 50A Front Mtd. Aux. Contact- NO AND NC MMP0 Circuit Breaker- Supply Fan 50A MMP- Supply Fan 36-50A MMP- Supply Fan 8-40A B Link Link C Lugs- MMP0 (kit of 3pc.) E Phase Barrier OL0 Overload- Supply Fan 50-00A A Terminal Block- Supply Fan N/S CB0 Circuit Breaker- Supply Fan 50A Circuit Breaker- Supply Fan 5A Circuit Breaker- Supply Fan 60A Circuit Breaker- Supply Fan 50A N/S Lugs- CB0 (kit of 3pc.) N/S= Not Shown on Diagram. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

211 Section N- Main Control Box Power Panel: (04/03 & Later) Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued 50 HP Motor- Code 3= S*Y Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 50A Contactor- Supply Fan 65A Front Mtd. Aux. Contact- NO AND NC MMP0 Circuit Breaker- Supply Fan 50A MMP- Supply Fan 45-63A MMP- Supply Fan 36-50A B Link E Phase Barrier OL0 Overload- Supply Fan 50-00A A Terminal Block- Supply Fan N/S CB0 Circuit Breaker- Supply Fan 80A Circuit Breaker- Supply Fan 60A FB0 Fuseblock- Supply Fan Fuse - Supply Fan 5A Fuse - Supply Fan 75A N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

212 Control Box Power Panel: (04/03 & Later) Compressor MMP thru 4 and Contactor M thru 4 Unit Size 045D MMP 3 Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact 3B Link Link 3B 3A Spacer Contactor Front Mtd. Aux. Contact A Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30/ MMP- 4 & M- 4 Contactor Link Detail Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 40A Contactor- Compressor 3A Contactor- Compressor 5A A Front Mtd. Aux. Contact- NO AND NC Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP- 4 Motor Protector- Compressor 36-45A Motor Protector- Compressor 8-40A Motor Protector- Compressor 4-0A Motor Protector- Compressor - 6A B Link Link N/S Busbar Busbar N/S Busbar Feeder Terminal Busbar Feeder Terminal N/S= Not Shown on Diagram. 08v V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

213 Control Box Power Panel: (04/03 & Later) Compressor MMP thru 4 and Contactor M thru 4 Unit Size 050, 05D MMP Front Mtd. Aux. Contact 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor MMP- 4 & M- 4 Contactor Link Detail 08/30V 3 MMP Link 3B 3A Contactor Spacer MMP- 4 & M- 4 Contactor Link Detail Front Mtd. Aux. Contact 3B Link Contactor A Front Mtd. Aux. Contact MMP- 4 & M- 4 Contactor Link Detail 0 50, 05 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor 3A Contactor- Compressor 5A A Front Mtd. Aux. Contact- NO AND NC Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP- 4 Motor Protector- Compressor 45-63A Motor Protector- Compressor 7- A Motor Protector- Compressor 4-0A B Link Link Link N/S Busbar, position Busbar, position N/S Busbar Feeder Terminal Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

214 Control Box Power Panel: (04/03 & Later) Compressor MMP thru 4 and Contactor M thru 4 Unit Size D Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B A Contactor A 3B Contactor Link MMP- 4 & M- 4 Contactor Link Detail 08/30V MMP- 4 & M- 4 Contactor Link Detail 460/ Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 5A A Front Mtd. Aux. Contact- NO AND NC Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC MMP- 4 Motor Protector- Compressor 45-63A Motor Protector- Compressor - 3A Motor Protector- Compressor 8-5A B Link Link N/S Busbar, position N/S Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 4

215 Control Box Power Panel: (04/03 & Later) Compressor MMP thru 4 and Contactor M thru 4 Unit Size 068D 3 3 Front Mtd. Aux. Contact Link 3B A Front Mtd. Aux. Contact A 3B 068 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 3A A Front Mtd. Aux. Contact- NO AND NC Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC MMP- 4 Motor Protector- Compressor 57-75A Motor Protector- Compressor 45-63A Motor Protector- Compressor - 3A B Link Link N/S Busbar, position N/S Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 5

216 Front Mtd. Aux. Contact Control Box Power Panel: (04/03 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size D 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A 3B Link 3A Spacer Contactor Contactor MMP- 6 & M- 6 Contactor Link Detail 08/30/ MMP- 6 & M- 6 Contactor Link Detail Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 40A Contactor- Compressor 3A Contactor- Compressor 5A A Front Mtd. Aux. Contact- NO AND NC Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP- 6 Motor Protector- Compressor 36-45A Motor Protector- Compressor 8-40A Motor Protector- Compressor 4-0A Motor Protector- Compressor - 6A B Link Link N/S Busbar, 3 position Busbar, 3 position N/S Busbar Feeder Terminal Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 6

217 Control Box Power Panel: (04/03 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 075D MMP Front Mtd. Aux. Contact 3 MMP 3 Link 3B Front Mtd. A Aux. Contact MMP- 6 & M- 6 Contactor Link Detail 08/30V 3 Link 3B 3A Contactor Front Mtd. Aux. Contact 3B Link Contactor A Front Mtd. Aux. Contact MMP- 6 & M- 6 Contactor Link Detail Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 65A Contactor- Compressor 3A Contactor- Compressor 5A A Front Mtd. Aux. Contact- NO AND NC Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC Front Mtd. Aux. Contact- NO AND NC MMP- 6 Motor Protector- Compressor 45-63A Motor Protector- Compressor 7- A Motor Protector- Compressor 4-0A B Link Link Link N/S Busbar, 3 position Busbar, 3 position N/S Busbar Feeder Terminal Busbar Feeder Terminal V V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 7

218 Control Box Power Panel: (04/03 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 079D, Circuit # MMP Front Mtd. Aux. Contact 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. A Aux. Contact MMP, 3, 5 & M, 3, 5 Contactor Link Detail 08/30V- Cir. # 3 MMP Link 3B 3A Contactor Spacer MMP, 3, 5 & M, 3, 5 Contactor Link Detail - Cir. # Front Mtd. Aux. Contact 3B Link Front Mtd. Aux. Contact A Contactor MMP, 3, 5 & M, 3, 5 Contactor Link Detail - Cir. # Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, 3, 5 Contactor- Compressor, Cir. # 65A Contactor- Compressor, Cir. # 3A Contactor- Compressor, Cir. # 5A A Front Mtd. Aux. Contact- NO AND NC, Cir # Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC, Cir. # Front Mtd. Aux. Contact- NO AND NC, Cir. # MMP, 3, 5 Motor Protector- Compressor, Cir. # 45-63A Motor Protector- Compressor, Cir. # 7- A Motor Protector- Compressor, Cir. # 4-0A B Link, Cir. # Link, Cir. # Link, Cir. # N/S Busbar, 3 position, Cir. # Busbar, 3 position, Cir. # N/S Busbar Feeder Terminal, Cir. # Busbar Feeder Terminal, Cir. # N/S= Not Shown on Diagram. 08V V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 8

219 Control Box Power Panel: (04/03 & Later) Compressor MMP thru 6 and Contactor M thru 6 Unit Size 079D, Circuit # Front Mtd. Aux. Contact MMP 3 Front Mtd. Aux. Contact MMP 3 Link 3B Front Mtd. Aux. Contact A Contactor MMP, 4, 6 & M, 4, 6 Contactor Link Detail 08/30V- Cir. # Front Mtd. Aux. Contact A 3B Contactor Link MMP, 4, 6 & M, 4, 6 Contactor Link Detail 460/- Cir. # 079 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 08V 30V M, 4, 6 Contactor- Compressor, Cir # 65A Contactor- Compressor, Cir # 40A Contactor- Compressor, Cir # 5A A Front Mtd. Aux. Contact- NO AND NC, Cir # Compressor MMP s & Parts Front Mtd. Aux. Contact- NO AND NC, Cir # MMP, 4, 6 Motor Protector- Compressor, Cir # 45-63A Motor Protector- Compressor, Cir # - 3A Motor Protector- Compressor, Cir # 8-5A B Link, Cir # Link, Cir # N/S Busbar, 3 position, Cir # N/S Busbar Feeder Terminal, Cir # N/S= Not Shown on Diagram. Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 9

220 Control Box Power Panel: (04/03 & Later) Condenser Fan Contactors, MMPs, & Fusing FanTrol Units (Code 47=, 3) MMP 8 Link 7B 7 Contactor Ref. Sch. Part Part No. Symbol Description Number Cond. Fan Contactors 7 M- 4 M- 4 Contactor- Cond. Fan Fan MMP s & Parts 7B Link- MMP MMP Motor Protector Motor Protector Motor Protector Motor Protector MMP Motor Protector Motor Protector Motor Protector Motor Protector MMP3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector MMP Motor Protector Motor Protector Motor Protector Motor Protector MMP Motor Protector Motor Protector Motor Protector Motor Protector MMP3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector N/S Bus Bar, Position Bus Bar, 3 Position Bus Bar, 4 Position N/S Bus Bar Top Feed N/S= Not Shown on Diagram. 08V 30V 08V 30V 08V 30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 0

221 Control Box Power Panel: (04/03 & Later) Condenser Fan Contactors, MMPs, & Fusing SpeedTrol Units (Code 47=, 4) Phase Barrier 8E 8 MMP Fuse Block 9 Link 7B 7 Contactor MMP & Contactor Detail Puller 9B 9A Fuse SpeedTrol Fusing Detail Ref. Sch. Part Part No. Symbol Description Number Cond. Fan Contactors 7 M - 4 M - 4 Contactor- Cond. Fan Fan MMP s & Parts 8 MMP Motor Protector Motor Protector Motor Protector Motor Protector MMP3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector MMP Motor Protector Motor Protector Motor Protector Motor Protector MMP3 Motor Protector Motor Protector Motor Protector Motor Protector MMP4 Motor Protector Motor Protector Motor Protector Motor Protector E Phase Barrier N/S Bus Bar, Position Bus Bar, 3 Position N/S Bus Bar Top Feed SpeedTrol Fusing 9 F, Fuse Block B Fuse Cover/Puller A F, Fuse- SpeedTrol Fuse- SpeedTrol Fuse- SpeedTrol N/S= Not Shown on Diagram. 08V 30V 08V 30V 08V 30V 46V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

222 Section N- Main Control Box Power Panel: (04/03 & Later) Heat/Energy Recovery Wheel Contactors, MMPs & Fusing Phase Barrier 8E MMP 8 Fuse Block 9 Link 7B 7 Contactor Cover 9B 9A Fuse MMP & Contactor Detail ERW Fusing Detail Unit Voltage Ref. Sch. Part Part No. Sym. Description Number ERW Contactor & Parts 7 M60 Contactor 7A B Link Heat Wheel MMP s & Parts 8 MMP60 Motor Protector 3.5-5A Motor Protector.8-.5A Motor Protector.- 3.A E Phase Barrier ERW Fusing 9 FB60 Fuseblock A F60 Fuse 7A Fuse 3A B Fuse Cover/Puller N/S CB60 Circuit Breaker 5A N/S= Not shown on diagram. Units With No Frost Protection Inverter (Code 4= Y,, ). Units w/ Frost Protection Inverter (Code 4= F). 08/30V Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page

223 Section N- Main Control Box Intelligent Equipment: Code 3= ****A, ****L (Mid 0 & Later) Intelligent Equipment from Daikin Applied (Code 3= ****A) is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation. A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality IE Express (Code 3= ****L) connects directly to your Daikin unit and offers a low cost, easy to install, entry-level solution to cloud equipment controls for those who don t need the Energy Management Module (EMM) found in the Intelligent Equipment offering. Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply. Click on this link to access the RPL for Intelligent Equipment: Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS D Rev. AR 05/8 RPL / Page 3

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W Replacement Parts List No. 70005300 Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT 045-074 Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70003700 Revision U 07/2 Roofpak Applied Rooftop Units RPS, RDT, RFS, RCS Sizes 045-079 Tons Vintage D R40a To find your Daikin McQuay Parts distributor, call -800-377-2787 or

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision G 01/2019 Replacement Parts List No. 700052600 Revision G 0/209 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017 Replacement Parts List No. 110502600 Revision I 09/2017 McQuay Superpak Applied Rooftop Units RRS, RSS 018-071 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

RoofPak Applied Rooftop Systems Air Handler

RoofPak Applied Rooftop Systems Air Handler Installation and Maintenance Manual IM 987 RoofPak Applied Rooftop Systems Air Handler Group: Applied Air Systems Part Number: IM 987 Date: May 009 RAH 047C - 077C,,000 to 50,000 cfm RDS 800C - 80C, 4000

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018 Replacement Parts List No. 57113900 Revision AB 06/2018 McQuay Westinghouse Centrifugal Chiller PF, PFH 063 Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information