Index Disconnect switches. Disconnect switches. Non-fusible and fusible disconnect switches Accessories

Size: px
Start display at page:

Download "Index Disconnect switches. Disconnect switches. Non-fusible and fusible disconnect switches Accessories"

Transcription

1 Index - Non-fusible and fusible disconnect General information Versatility, broad range, compact size... International acceptance, installation options, broad range of accessories...2 Mounting, mounting positions, incoming power feeds, terminal connections...3 Finger proof, door interlock, padlockable, positive opening operation...4 Welded contact protection, clear position indication, visible blades, constant control...5 High performance, superior short circuit protection, fuse isolation...6 Non-fusible disconnect Approvals and ratings...7 Ordering details guide Ordering details information...0 Base and DIN rail mounted, A... Door mounted, 6-00 A...2 Side operated...3 Flange & double throw (change-over) OTDC Solar...8 Fusible disconnect Approvals and ratings... Ordering details guide...20 Ordering details information...2 Base & DIN rail mounted...22 Side operated and flange High speed fuse pattern Accessories Standard handles & shafts Auxiliary contacts...33 Terminal lugs...34 Terminal shrouds...35 Additional poles...36 Fuse monitors & carriers...37 Miscellaneous accessories & replacement parts...38 Conversion, transfer & bypass mechanisms...39 Enclosed disconnect General information Non-fusible 3 pole, A pole, A...46 Fusible 3 pole, A...47 Accessories...48 Technical data Technical data Auxiliary contact timing diagrams NEMA Environmental ratings Definition...66 Approximate dimensions Low Voltage Products & Systems.A

2 Notes.B Low Voltage Products & Systems

3 Di s sw con itc nec he t s Non-fusible & fusible disconnect, open style General information Versatility ABB disconnect are designed to offer maximum versatility in many ways. Broad range ABB's open style non-fusible have seventeen amperage sizes from A The fusible range is A. All sizes are compact, heavy duty, 600V, disconnect. Many sizes are available in 2, 3, 4, 6, and 8 pole configurations. ABB s offer also includes non-fusible DC from A specifically designed for solar applications, heavy duty safety ( A) and general duty enclosed, both fusible fusible ( A) and non-fusible ( A). Compact size The non-fusible disconnect ' compact dimensions allow panel size reduction in new applications or easily retrofit into space-sensitive existing installations. The fusible disconnect occupies only little more panel space than the appropriate fuses.. Low Voltage Products & Systems

4 General information International acceptance UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) UL File # E04, CSA File #58077 For OT30-OT200, OS and OETL_ with pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. and are horsepower and ampere rated. UL508 (CSA 22.2 No. 4) UL File # E63822, CSA File #58077 For OT6 OT80, OH_ selector handles Suitable for use in equipment or machinery as motor controllers & motor disconnects and are horsepower and ampere rated. IEC Tested in accordance to IEC and 3. CE Compliance with the European Machine Directive IEC/EN Installation options Rotary through the door: available in all sizes, non-fusible A; fusible A Flange: versions available in A sizes. A rotary disconnect may be installed nearly anywhere in a control panel mounting is not limited to the upper right hand corner of the panel. Mount the disconnect where it conveniently fits in your panel and simply install the handle on the door, in line with the disconnect. The disconnect and handle are mechanically linked through an easily adjusted shaft. This allows fast and easy installation into panels of different depths and layouts. Broad range of accessories Handles UL/NEMA type, 3R, 2, 4, 4X; IP54, 65, 66 Auxiliary contacts available for every disconnect size Additional power poles Additional terminal poles (neutrals & grounds) Terminal shrouds 6 & 8 pole mechanisms Transfer mechanisms Bypass mechanisms Mechanical interlock mechanisms Electro-mechanical interlock mechanisms.2 Low Voltage Products & Systems

5 General information Mounting offer several mounting possibilities: Door mounting on an enclosure door or sidewall for non-fusible, 6-00 A DIN rail mounting for non-fusible, A; and fusible, A Base mounting with screws for all disconnect sizes Adjustable mounting feet for non-fusible, A, and fusible A Mounting positions offer several mounting possibilities: Terminal connections Versatile connecting possibilities for non-fusible and fusible Ring tongue crimp on lugs Direct bus Terminal lugs Finger proof Dead-front construction plus terminal shrouds reduce the risk of touching live parts, improving safety and reliability of the instalation Incoming power feed can be used equally well with either top or bottom incoming power feed. Low Voltage Products & Systems.3

6 General information Modular construction Different pole configurations make it easy to install the disconnect inside the enclosures as well as enhance the external operation through the pistol handles. Door interlock The handle and shaft provide a door interlock; the door cannot be opened when the switch is in the ON position. NOTE: Some handles provide a method for qualified personnel to circumvent the door interlock. This is commonly referred to as a defeater mechanism. Padlockable Handles can be padlocked in the OFF position with up to three padlocks. Additionally - with a direct mount handle - the switch mechanism can be directly padlocked in the OFF position when the door is open. NOTE: Some handles can be ordered with the ability to padlock in both the ON & OFF positions, please consult your ABB sales office. Positive opening operation All operate according to the positive opening operation principle. This means the contacts are opened and closed by a driven mechanism, a solid moving bridge, not merely springs. This provides reliable position indication to the user; if the disconnect is in the OFF position, the contacts are open..4 Low Voltage Products & Systems

7 General information Welded contact protection Positive opening operation safeguards users in case of welded contacts caused by an overload or short circuit. The handle cannot reach the OFF position unless the contacts are truly open. If any or all of the contacts are welded shut, the disconnect mechanism will only allow the handle to operate a maximum of 45. This safeguards personnel by: Alerting them a problem has occurred Maintaining the door interlock and Not allowing a padlock to be inserted Clear position indication All disconnects and handles have clear ON and OFF designations. Whether the door is open or closed, it is possible to simply look at the disconnect and determine if it is ON or OFF. Visible blades Visible blades offer additional safety for non-fusible, A Track resistant material Excellent track resistant material reduces the risk of flash-over between phases in even the most severe circumstances. Constant control for non-fusible disconnect The OT6 to OT00 provide the user with constant control over the power circuit. Whether the enclosure door is open or closed, qualified personnel have the ability to manually operate the disconnect. This is most meaningful when qualified personnel are working with the enclosure door open: In case of an emergency down-stream, the main three phase power can be disconnected immediately using the black, direct mounted handle. Low Voltage Products & Systems.5

8 General information High performance The mechanism is quick-make/quick-break, meaning the contacts operate independently of the speed and force at which the handle is operated. This, in combination with unique, patented self-cleaning contacts, provides a long, reliable, electrical life. Superior short circuit protection Fuses efficiently limit the peak let-through current, i 2 t, during a fault better than any other product, contributing to safety and reliability. Selectivity and coordination are easily accomplished with fused protection. Fusible disconnect accept a wide range of fuses: Class CC 30A Class J A Class L A Fuse isolation Fused have contacts on both sides of the fuse. The fuses are totally isolated in the OFF position, reducing the risk of electric shock to authorized personnel even if the disconnect is being back fed..6 Low Voltage Products & Systems

9 Non-fusible disconnect, open style A, 600 VAC 6-32 A, 600 VDC A, 000 VDC Non-fusible Non-fusible ABB disconnect switch family includes several different amperage sizes from 6 to 2000 A. The basic construction provides flexibility, safety, and high performance in an extremely compact size. ABB SwitchLine is a perfect choice for all switching applications from industrial motor control to construction safety. International acceptance UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) UL File # E04, CSA File #58077 For OT30, OT60, OT00, OT200, OT400, OT600, OT800, OT200 OETL-NF600, OETL-NF2000, OH_ pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. and while being horsepower and ampere rated. UL508 (CSA 22.2 No. 4) UL File # E63822, CSA File #58077 For OT6 80, OH_ selector handles Suitable for use in equipment or machinery as motor controllers & motor disconnects, horsepower and ampere rated. IEC Tested in accordance to IEC and CE Compliance with the European Machine Directive IEC/EN For a complete offer including other standards such as IEC, visit: Low Voltage Products & Systems.7

10 Non-fusible General information Selection guide OT6 00 OT6F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT00F3 3 pole OT6F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT00F3 General purpose A amp rating Approvals 2 pole N/A N/A N/A N/A N/A N/A N/A N/A 3 pole UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 4 pole UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC Technical ratings UL,CSA 2 Max operating voltage V Max horsepower rating Three phase 240V HP V HP V HP Single phase 20V HP V HP Technical ratings IEC 2 Rated insulation and operational voltage. AC20 and DC20 V Rated thermal current, I th AC 20/DC 20 open A AC 20/DC 20 enclosed A AC 2A 500V A V A Rated operational power AC23 400/45V kw V kw Physical characteristics Weight 3 3 pole lb Dimension 3 pole H in W in D in Accessories Terminal lug kit Integral Integral Integral Integral Integral Integral Integral Integral Terminal shroud Auxiliary contact Shaft/handle diameter 6mm 6mm 6mm 6mm 6mm 6mm 6mm 6mm.24" x.24".24" x.24".24" x.24".24" x.24".24" x.24".24" x.24".24" x.24".24" x.24" Handle UL/NEMA type Type, 3R, 2 Type, 3R, 4, 4X, 2 Handle type Selector Pistol Recommended pistol handle length 45-65mm 45-65mm 45-65mm 45-65mm 45-65mm 45-65mm 45-65mm 45-65mm Maximum recommended shaft length 290mm 290mm 290mm 290mm 290mm 290mm 290mm 290mm Conversion kits 6 pole Transfer Bypass Mechanical interlock Electrical interlock = Available = Not available UL listed are also listed for CSA Standards. 2 For complete technical information please see pages only..8 Low Voltage Products & Systems

11 General information Selection guide OT OETL-NF Non-fusible OT200U03 OT400U03 OT600U03 OT800U03 OT200U03 OETL-NF600SW OETL-NF2000SW 3 pole OT200U03 OT400U03 OT600U03 OT800U03 OT200U03 OETL-NF600SW OETL-NF2000SW General purpose A amp rating Approvals 2 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 3 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 4 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC Technical ratings UL,CSA 2 Max operating voltage V Max horsepower rating Three phase 240V HP V HP V HP Single phase 20V HP 240V HP Technical ratings IEC 2 Rated insulation and operational voltage. AC20 and DC20 V Rated thermal current, I th AC 20/DC 20 open A AC 20/DC 20 enclosed A AC 2A 500V A V A Rated operational power AC23 400/45V kw V kw Physical characteristics Weight 3 3 pole lb Dimension 3 pole H in W in D in Accessories Terminal lug kit OZXA-200 OZXA-400 OZXA-800 OZXA-200 OZXA-200 OZXA-28 OZXA-28/2 Terminal shroud Auxiliary contact Shaft/handle diameter 6mm 2mm 2mm 2mm 2mm 2mm 2mm.24" x.24".47" x.47".47" x.47".47" x.47".47" x.47".47" x.47".47" x.47" Handle UL/NEMA type Type, 3R, 2 Type, 3R, 4, 4X, 2 Handle type Selector Pistol Recommended pistol handle length 65-80mm 25-75mm 25-75mm 25-75mm 25-75mm 25-75mm 25-75mm Maximum recommended shaft length 290mm 595mm 595mm 595mm 595mm 595mm 595mm Conversion kits 6 pole Transfer Bypass Mechanical interlock Electrical interlock S = Standard feature = Available = Not available UL listed are also listed for CSA standards. 2 For complete technical information please see pages only. 4 IEC Utilization Category B, Infrequent operation. Low Voltage Products & Systems.9

12 Non-fusible Selection information Standard part designation Non-Fusible OT Switches (6 to 00A) OT 6 F 3 C Amperage 6 = 20 amps* 63 = 60 amps* 60 = 60 amps 25 = 30 amps* 80 = 80 amps* 00 = 00 amps 40 = 40 amps* 30 = 30 amps Number of Poles 3 = 3 poles 4 = 4 poles 6 = 6 poles Special Configuration Blank = Non-fusible disconnect switch C = Double throw switch *culus 508 listed. OT30_, OT60_ and OT00_ are culus 98 listed Non-Fusible OT Switches (200A and above) OT 200 U 03 C Amperage 200 = 200 amps 400 = 400 amps 600 = 600 amps 800 = 800 amps 200 = 200 amps Number of Poles & Placement of Mechanism 02 = 2 poles to right of mechanism 03 = 3 poles to right of mechanism 30 = 3 poles to left of mechanism 2 = pole to left, 2 poles to right of mechanism Special Configuration Blank = Non-fusible disconnect switch C = Double throw switch 04 = 4 poles to right of mechanism Selector Handles OHB S P H All OT200U_, OT400U_, OT600U_, _OT800U_ and OT200U_ are culus 98 listed. Handle Color B = black Physical Size Y = Red/Yellow Pistol Handles O H B 65 J 6 E0 Connection to disconnect A = external shaft P = snap on R = screw Protection Class H = Nema J= Nema, 3R, 2 Handle Color B = Black Y = Red/Yellow M = Stainless Steel Handle Length 65 = 65mm 80 = 80mm 25 = 25mm 45 = 45mm 274 = 274mm 330 = 330mm Environmental Rating J =, 3R, 2 L =, 3R, 2, 4, 4X Shaft Diameter 6 = 6mm 2 = 2mm Special Configuration Blank = for disconnect, fusible and non-fusible E0 = 3 position double throw handle EH = Stainless steel hasp Part designation keys are provided for reference only. Not all variations or configurations are available..0 Low Voltage Products & Systems

13 Base & DIN rail mounted A Non-fusible For a complete assembly, please select one of each: disconnect (page.) handle (page.30) shaft (page.32) terminal lug kit (page.34) NOTE: For additional accessories, see pages (Lug kits only necessary on 200A and above) UL Standard UL 508 UL 98 UL general purpose amp rating OT200U OT400U02 OT_F_ OT_U_ 2 Pole 3 Pole 4 Pole 2 6 Pole 3 OT6F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT00F3 OT200U03 OT200U30 OT200U2 OT400U03 OT400U30 OT400U2 OT200U04 OT400U OT600U02 OT600U03 OT600U04 + Handle OH_S_ OH_B_ Shaft OXS_ OXP_ OT6F6 OT25F6 OT40F6 OT63F6 OT80F6 OT30F6 OT60F6 OT00F6 + Lug kit OZXA_ 800 OT800U02 OT800U03 OT800U OT200U02 OT200U03 OT200U OETL-NF6002SW OETL-NF600SW OETL-NF6004SW 2000 OETL-NF20002SW OETL-NF2000SW OETL-NF20004SW Bulk packed 3 Pole, 600 VAC Switches - order quantity is for bulk package UL Standard UL508 UL98 UL general purpose amp rating Bulk pack Quantity OT6F3/B50 OT25F3/B50 OT40F3/B50 OT63F3/B50 OT80F3/B50 OT30F3/B25 OT60F3/B25 OT00F3/B25 Above 200A, base mount with screws only. A snap on fourth pole may be added on 6-00A. See page.36. For a 6 or 8 pole switch 200 A and above, a conversion mechanism accessory kit can be used with two 3 or 4 pole. See page.39. Vertical busbar provided as standard on OETL-NF600-OETL For alternate back or edgewise mounting busbar, see page.38. DIN rail mounting required adaptador OSGZD Low Voltage Products & Systems.

14 Non-fusible Door mounted 6-00 A For a complete assembly, please select one of each:2 disconnect (page.2) handle (page.3) NOTE: For additional accessories, see pages = OT_FT_ Handle OH_S_ Snap-on mounted handle Screw mounted handle 3 Pole 4 Pole OT_FT UL Standard UL508 UL98 UL general purpose amp rating OT6FT3 OT25FT3 OT40FT3 OT63FT3 OT80FT3 OT30FT3 OT60FT3 OT00FT3 See page.36 for fourth poles Bulk packed 3 Pole, 600 VAC Switches - order quantity is for bulk package UL Standard UL508 UL98 UL general purpose amp rating Bulk pack Quantity OT6FT3/B50 OT25FT3/B50 OT40FT3/B50 OT63FT3/B50 OT80FT3/B50 OT30FT3/B25 OT60FT3/B25 OT00FT3/B25 Door mounted do not provide door interlock 2 Door mounted do not require shafts.2 Low Voltage Products & Systems

15 Special configuration Side operated A Non-fusible For a complete assembly, please select one of each: disconnect handle shaft terminal lug kit + + OSNF_-S Handle OH_J_E00S Shaft OXP_X_ OSNF30-S Side operated disconnects 3 pole UL general purpose amp rating Maximum horsepower rating Three phase 200V 208V 240V 480V 600V Weight (Lbs.) OSNF30-S OSNF60-S OSNF00-S Handles UL/NEMA type Color Length inches/mm Marking Defeatable Padlockable Weight (Lbs.) OH_J_ For use with OSNF30-S Black, 2, 3R Red/Yel 2.65/65 O/I & Off/On Yes Yes 0.29 OHB65J6E00S OHY65J6E00S For use with OSNF60-S OSNF00-S Black, 2, 3R 3./80 O/I & Off/On Yes Yes 0.30 Red/Yel OHB80J6E00S OHY80J6E00S OXP6X_ Shafts For use with: OSNF30-S OSNF60-S OSNF00-S Length Weight Description (Inches/mm) (Lbs.) 6.7/70.24 x.24 (6 x 6mm) 0.08 OXP6X70 8.3/20.24 x.24 (6 x 6mm) 0.0 OXP6X20 Terminal lug kits For use with: Wire Wire Lugs Weight size type per kit OSNF30-S #8 8 Cu Integral OSNF60-S #4 4 Cu Integral OSNF00-S #4 2/ Cu/Al 6 OZXA-24 OZXA-24 For 00 A disconnect only Fusible with solid links installed Low Voltage Products & Systems.3

16 Non-fusible Special configurations Shaft operated flange A + + Assembly OT_F3-F Handle DSFHN_ Flange operated (Shaft) - 3 poles Shaft OTFS_ UL general purpose amp rating OT30F3-F OT60F3-F OT00F3-F OT_F_-F Flange handles for use with OT30, OT60, OT00 UL/ NEMA type, 3R, 2 4, 4X Marking OFF/ON OFF/ON Defeatable No No Padlockable Yes Yes DSFHN-HS2 DSFHN-HS4 Shafts For use with: Maximum enclosure depth (inches) DSFHN-HS_ OT30 - OT00F OTFS-6 OTFS-24 OTFS_ Flange operated fusible and non-fusible disconnect ABB s solutions comply with NFPA79 requirements for Flange Operated Fusible and Non-fusible Switches. NFPA 79 requires main disconnecting means to be operable without the use of accessory tools or devices, independent of door position. This code also includes an interlocking provision to prevent the closing of disconnects while the enclosure door is open, unless an interlock is operated by a deliberate action. The flange operated disconnect are available as ridged shaft or flexible cable operated versions. The cable operated version allows you to install the disconnect switch virtually anywhere in the enclosure depending on the length of the cable. Cables are available in lengths up to 84 inches. The designs are cost-effective NFPA 79 solutions offering quick and easy installation..4 Low Voltage Products & Systems

17 Special configurations Cable operated flange A Non-fusible Switch Handle Cable Operating mechanism 2 Lug kit OT_F3 Flange Operated (cable) - 3 poles UL general purpose amp rating OT30F3 OT60F3 OT00F3 OT200U OT200U OT400U30-FC 600 OT600U30-FC 800 OETL-NF800A-FC 200 OETL-NF200-FC Flange handles UL98; UL file #E0 For use with: Environmental rating OHFC2 OT30-00F3, OT200U30/03 OT400U30-FC, OT600U30-FC, OETL-NF800-FC, OETL-NF200-FC NEMA, 3R, 2 NEMA 4, 4X NEMA, 3R, 2 NEMA 4, 4X OHFC2 OHFC4 K7FCH K7FCH4 Flexible cables OXCL_ For use with: OT30-00F3, OT200U30/03 OT400U30-FC, OT600U30-FC, OETL-NF800-FC, OETL-NF200-FC Cable length (inches) OXCL36 OXCL48 OXCL60 OXCL72 OXCL84 K7C048 K7C060 K7C072 K7C084 Operating mechanisms For use with: OT30-00F3 OT200U30, OT200U03 OT400U30-FC, OT600U30-FC, OETL-NF800-FC, OETL-NF200-FC MKCS MKCS4 Included For disconnects above 00 A Rotate the OT_03 disconnect 80 degrees to mount on the operating mechanism Operating mechanism required for OT Not required for OT (included) Low Voltage Products & Systems.5

18 Non-fusible Special configurations Accessories for flange operated disconnects A Terminal lug kits For use with OT200U30 Wire Wire Description Lugs per kit size type #4 300 kcmil Cu/Al - 6 OZXA-200 OT400U30-FC #2-600 kcmil Cu/Al - 6 OZXA-400 OT600U30-FC (2) #2-600 kcmil Cu/Al - 6 OZXA-800 OETL-NF800-FC (2) #2-600 kcmil Cu/Al - 6 OZXA-30 OETL-NF200-FC (4) #2-600 kcmil Cu/Al - 6 OZXA-28 OTS_L_ Terminal shrouds For use with Description, qty per kit For full protection order Weight (lbs.) OT30 - OT00 3 Pole shroud, pc 2 kits 0.02 OTS25T3 OT200 Single Pole Long Type Shroud, 3 pcs 2 kits 0.2 OTS250GL/3 OT200 Single Pole Short Type Shroud, 3 pcs 2 kits 0.3 OTS250GS/3 OT400U30-FC 3 pole shroud, pc 2 kits 0.3 OTS403 OT600U30-FC 3 pole shroud, pc 2 kits 0. OTS603 OETL-NF800 3 Pole shroud, 2 pcs kit 0.88 OETL-2X800A OETL-NF200 3 Pole shroud, 2 pcs kit.2 OETL-2X OTS_S_ Door hardware NEMA 2 Item Safety door latch, 2 points, door less than 40" high Safety door latch, 3 points, door greater than 40" high KDH2R KDH3R OTS_03.6 Low Voltage Products & Systems

19 Special configuration Double throw disconnects A Non-fusible For a complete assembly, please select one of each: disconnects (page.7) handle (page.30) shaft (page.32) terminal lug kit (page.34) bridging bar (page.7) NOTE: For additional accessories, see pages Handle Shaft Lug kit Bridging bars 3 Pole 4 Pole UL only UL general purpose amp rating OT_F3C UL508 UL OT6F3C OT25F3C OT40F3C OT63F3C OT80F3C OT30F3C OT60F3C OT00F3C OT200U03C OT200U30C OT400U03C OT400U30C OT200U04C OT400U04C 600 OT600U03C OT600U04C 800 OT800U03C OT800U04C OT_U_C Parallel connection kits / jumpers Required for OT6_C through OT00_C Description For use with: 3 Pole Kit OT6...40F3C OT F3C OT30F3C, OT60F3C, OT00F3C OZXA33 OZXA38 OZXA40 OZXA_ 4 Pole kit OT6...40F3C + 4th pole OT F3C + 4th pole OT F3C + 4th pole OZXA32 OZXA39 OZXA4 OTZC_ Bridging busbar kits Required for OT200_C through OT800_C Description For use with: 3 Pole Kit 4 Pole kit OT200_C OT400_C OT600_C OT800_C OT200_C OT400_C OT600_C OT800_C OTZC3 OTZC23 OTZC33 OTZC53 OTZC4 OTZC24 OTZC34 OTZC54 Bridging bars are required on A double throw to operate as standard double throw. Otherwise, they will operate as two mechanically interlocked. For disconnects above 00 A A snap on power pole may be added to build a 4 pole 6-00A double throw switch. See page.36 Low Voltage Products & Systems.7

20 Non-fusible OTDC Solar disconnect 6-32 A, 600 VDC OTDC_, base or DIN-rail mounting, UL508i Touch-safe IP20 protected terminal clamps included. Types OTDC6 32US include premounted short circuit link OEZXY86. Shafts and handles to be ordered separately. Single circuit (2 poles in series) Number Rating [A] OTDC6US2 of poles UL508i 600 VDC ue Number 2 6 OTDC6US OTDC25US2 Handle & Shaft diam. 6 mm 6 mm Weight (lbs) Double circuit (2 x 2 poles in series) OTDC6US4 Number Rating [A] of UL508i Handle poles 600 VDC ue Number & Shaft diam. Weight (lbs) 4 6 OTDC6US4 6 mm OTDC25US4 6 mm OTDC32US4 6 mm 0.33 OTDC6US6 Triple circuit (3 x 2 poles in series) Number of poles Rating [A] UL508i 600 VDC ue Number Handle & Shaft diam. 6 6 OTDC6US6 6 mm Weight (lbs) 0.33 Wiring diagrams + + (-) (-) + + (-) (-) (-) (-) (-) (-) (-) (-) (-) + (-) OTDC_US2 OTDC_US4 OTDC_US6 Door-mounted versions available. Please, consult ABB. For handles and shafts, please refer to page.30.8 Low Voltage Products & Systems

21 OTDC Solar disconnect A, 000 VDC switche s N o n-fusible OTDC_, base mounting, UL98B Shafts and handles are not included. Phase barriers are included if mandatory. Included terminal bolts: OTDC : M8x25 - OTD : M0x30 - OTDC : M2x40 - Short circuit links/jumpers included and pre-mounted. OTDC US02 Single circuit, 000 VDC Number of poles Rating [A] UL98B / 000 V Front operated, mechanism at the end of the switch. ue Number Handle & Shaft diam. Weight (lbs) Recommended handle Pistol / Direct mount (K) 2 00 OTDC00US02 6 mm 2.65 OHB80L6 / OTDV250EK OTDC200US02 6 mm OTDC250US02 2 mm 9.70 OHB45L2 / OTDV400EK OTDC320US02 2 mm OTDC400US02 2 mm 9.70 OTDC US Front operated, mechanism between the poles OTDC00US 6 mm 2.65 OHB80L6 / OTDV250EK OTDC200US 6 mm OTDC250US 2 mm 9.70 OHB45L2 / OTDV400EK OTDC320US 2 mm OTDC400US 2 mm OTDC600USPP22 2 mm 7.4 OHB45L2 / OTDV400EK OTDC600USPP22 OTDC US22 Double circuit and load side combining, 000 VDC Front operated, mechanism 2x2 00 OTDC00US22 6 mm 5.5 OHB80L6 / OTDV250EK 2x2 80 OTDC80US22 6 mm 5.5 2x2 250 OTDC250US 2 2 mm 4.55 OHB45L2 / OTDV400EK 2x2 320 OTDC320US22 2 mm x2 400 OTDC400US22 2 mm 4.55 OTDC US22 Side operated versions are also available, please consult ABB. Low Voltage Products & Systems.

22 OTDC Solar disconnect A, 500 VDC Single circuit, 500 VDC Number Recommended of poles Rating [A] UL98B / 500 V ue Number Handle & Shaft diam. Weight (lbs) handle Pistol / Direct mount (K) Front operated, mechanism OTDC250USV2 2 mm 2.56 OHB45L2 / OTDV400EK OTDC320USV2 2 mm OTDC400USV2 2 mm 2.56 OTDC USV2 Wiring diagrams 000 VDC +(-) +(-) +(-) +(-) +(-) +(-) +(-) +(-) +(-) +(-) 2 2 OTDC_US OTDC_US02 OTDC600USPP22 OTDC US22 +(-) +(-) +(-) 2 +2 LOAD OTDCKIT400B0 for OTDC US22, to be ordered separately OTDC US VDC +(-) +(-) OTDC USV2.B Low Voltage Products & Systems

23 Fusible disconnect A, 600 VAC Fusible Fusible ABB disconnect switch family includes seven different amperage sizes from 30A to 200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting capacity and long electrical life while occupying only little more panel space than the appropriate fuses. The basic construction provides flexibility and high performance in an extremely compact size. ABB's disconnects are a perfect choice to withstand the heat and humidity of the tropics, the extreme cold of the arctic and any rugged industrial environment you may have. International acceptance ABB fusible are available with a wide range of fuse clip options: UL USA CSA Canada DIN Europe BS United Kingdom NFC France Ultra-rapid As well as the corresponding approvals: UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) UL File # E04, CSA File #58077 For OS30 200, OH pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. Horsepower and ampere rated. IEC Tested in accordance to IEC and 3 CE Compliance with the European Machine Directive IEC/EN For a complete offer including other standards such as IEC, BS etc, visit: Low Voltage Products & Systems

24 Fusible Selection guide OS OS30FA_2 OS60GJ03 OS00GJ03 OS200J03 OS400J03 OS600J03 OS800L3 OS200L03 3 pole OS30FACC2 OS30FAJ2 OS60GJ2 OS00GJ03 OS200J03 OS400J03 OS600J03 OS800L3 OS200L03 General purpose amp rating A Approvals 2 pole N/A N/A UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 3 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 4 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC Technical ratings (UL,CSA) Max operating voltage V Max horsepower rating Three phase 240V HP V HP V HP Single phase 20V HP V HP 3 3 UL fuse class CC J J J J J J L L Technical ratings (IEC) Rated insulation and operational voltage. AC20 and DC20 V Rated thermal current, I th AC 20/DC 20 open A AC 20/DC 20 enclosed A AC 2A 500V A V A Rated operational power AC23 400/45V kw V kw Physical characteristics Weight 3 pole switch lb pole lb Dimension 3 pole H in W in D in Accessories Double break contacts S S S S S S S S S Fuse cover S S S S S S S S S Terminal lug kit Integral Integral Integral OZXA-24 OZXA-200 OZXA-400 OZXA-800 OZXA-800 OZXA-200 Terminal shroud Not required Not required Not required Auxiliary contact Shaft/handle diameter 6mm 6mm 6mm 6mm 6mm 2mm 2mm 2mm 2mm.24 x.24".24 x.24".24 x.24".24 x.24".24 x.24".47 x.47".47 x.47".47 x.47".47 x.47" Handle UL/NEMA type Type, 3R, 2 Type, 3R, 4, 4X, 2 Recommended pistol handle length 45-65mm 45-65mm 45-65mm 45-65mm 65-80mm 25-75mm 25-75mm 25-75mm 25-75mm Maximum recommended shaft length 290mm 290mm 290mm 290mm 290mm 535mm 535mm 535mm 535mm Electrical interlock S = Standard = Available = Not available UL listed are also listed for CSA Standards..2 Low Voltage Products & Systems

25 Selection information Fusible Standard part designation Fusible OS Switches (30A) OS 30 F A J 22 F Amperage 30 = 30 amps Fuse Type/Class J = Class J fuse compatible CC= Class CC fuse compatible Fusible OS Switches (60 to 00A) OS 00G J 03 Number of poles and placement of the mechanism 2 = Pole to the left of mechanism, 2 poles to the right of mechanism 22 = 2 Poles to the left of mechanism, 2 poles to the right of mechanism Amperage 60 = 60 amps 00 = 00 amps Fuse Type/Class J = Class J fuse compatible Number of poles and placement of the mechanism 03 = 3 Poles to the right of mechanism 04 = 4 poles to the right of mechanism Fusible OS Switches (200A and above) OS 200 J 04 F Amperage 200 = 200 amps 400 = 400 amps 600 = 600 amps 800 = 800 amps 200 = 200 amps Fuse Type/Class J = Class J fuse compatible L = Class L fuse compatible Number of poles and placement of the mechanism 03 = 3 Poles to the right of mechanism 2 = Pole to left of mechanism, 2 poles to right 30 = 3 Poles to the left of mechanism 04 = 4 poles to the right of mechanism 22 = 2 Poles to left of mechanism, 2 poles to right Pistol Handles O H B 65 J 6 E0 Handle Color B = Black Y = Red/Yellow M = Stainless Steel Handle Length 65 = 65mm 80 = 80mm 25 = 25mm 45 = 45m 75 = 75mm 274 = 274mm 330 = 330mm Environmental Rating J = Nema, 3R, 2 L = Nema, 3R, 2, 4, 4X Shaft Diameter 6 = 6mm 2 = 2mm Special Configuration Blank = for disconnect, fusible and non-fusible E0 = 3 position double throw handle EH = Stainless Steel Hasp Part designation keys are provided for reference only. Not all variations or configurations a e available. Low Voltage Products & Systems.2

26 Fusible Base & DIN rail mounted A, UL fuse class CC, J and L For a complete assembly, please select one of each: switch (page.22) handle (page.30) shaft (page.32) terminal lug kit (page.34) NOTE: For additional accessories, see pages Switch OS_ Handle OH_J_ Shaft OXP_X_ Lug Kit OZXA_ OS30FA_2 UL 98 UL general purpose amp rating 30 UL Fuse Type 600V J CC 2 Pole 3 Pole 4 Pole 60 J OS60GJ02 00 J 200 J OS200J J OS400J02 OS00GJ02 OS30FAJ2 OS30FACC2 OS60GJ2 OS60GJ03 OS00GJ2 OS00GJ03 OS200J03 OS200J30 OS200J2 OS400J03 OS400J30 OS400J2 OS30FAJ22F OS30FACC22F OS60GJ04F OS00GJ04F OS200J04F OS400J04F 600 J OS600J02 OS600J03 OS600J04F OS60GJ L OS800L02 OS800L03 OS800L04F 200 L OS200L02 OS200L03 OS200L04F OS00GJ2 OS _03 For OS60 and OS00, please add the accessory OSGZD in order to mount on a DIN rail. OS200 and above are screw mounted only. Lugs only required for OS00 and above. 2 Rejection style fuses only.22 Low Voltage Products & Systems

27 Special configurations Side operated A, UL fuse class CC and J Fusible For a complete assembly, please select one of each: switch handle shaft terminal lug + + Switch OS_ Handle OH_J_ Shaft OXP_X_ OS60GJS30 Side operated fusible disconnects 3 poles UL general purpose amp rating UL fuse type 600V Maximum horsepower rating Three phase 200V 208V 240V 480V 600V Weight (Lbs.) 30 J OS30FAJS30 30 CC OS30FACCS30 60 J OS60GJS30 00 J OS00GJS30 Handles OS00GJS30 UL/NEMA type IEC type Color Length (Inches/mm) For use with OS30FA_S_, OS60GJS_ & OS00GJS_ Black, 3R, 2 IP65 Red/Yel For use with OS60GJS_ & OS00GJS_ Black, 3R, 2 IP65 Red/Yel Marking Defeatable Padlockable Weight 2.6/65 OFF/ON Yes Yes 0.29 OHB65J6E00S OHY65J6E00S 3./80 OFF/ON Yes Yes 0.30 OHB80J6E00S OXP6X_ Shaft For use with: OS30FA_S_, OS60GJS_ & OS00GJS_ Length Weight Description (Inches/mm) (Lbs.) 6.7/70.24 x.24 (6 x 6mm) 0.08 OXP6X70 8.3/20.24 x.24 (6 x 6mm) 0.0 OXP6X20 OZXA-24 Terminal lug kits For use with: OS30FA_S_ OS60GJS_ OS00GJS_ Wire size Weight Wire type Lugs per kit #8 8 Cu Integral #4 4 Cu Integral #4 2/ Cu/Al 6 OZXA-24 For OS60 and OS00, please add the accessory OSGZD in order to mount on a DIN rail. Lugs only required for OS00. 2 Rejection style fuses only Low Voltage Products & Systems.23

28 Fusible Special configurations Shaft operated flange A For a complete assembly, please select one of each Switch Handle Shaft Lug kit Flange operated fusible disconnects (shaft) 3 poles UL general purpose amp rating A UL fuse type 600V Maximum horsepower rating Three phase 240V 480V 600V OS30FAJ_ J CC J J OS30FAJF30 OS30FACCF30 OS60GJF30 OS00GJF30 Flange handles UL/ NEMA type Marking Defeatable Padlockable, 3R, 2 4, 4X OFF/ON OFF/ON No No Yes Yes DSFHN-HS2 DSFHN-HS4 Shafts For use with: Maximum enclosure depth (inches) OS30_ - OS00_ DSFHS-2 DSFHS-7 DSFHS-22 DSFHN-HS_ DSFHS-_ Terminal lug kits and accessories For use on: Description Wire size Wire type / additional info Qty. OS30_ OS60_ OS00_ OS30FA_ & OS60-00G_ OS30FA_ Lug Lug Lug Aux. Contact Aux. Contact #8 - #8 #4 - #4 #4-2/0 NO NC NC+ NO Cu Cu Cu/Al Up to 4 aux. contacts 2 max, mounted to the switch mechanism Integral Integral OZXA-24 OAG0 OA3G0 OA4BC OS30FA_ Adapter Needed for mounting OA_G_ aux. cont. on OS30FA_ OSZ4 Single Pole Long type shroud, 3 pcs OSS60GGL/3 OS00GJ_ Shroud Single Pole Short type shroud, 3 pcs OSS60GGS/3 OSZ4 OZXA-24 For 00 A and above. OS come with internal lugs. OSZ4 adaptor is needed to mount on OS30FA_ For full protection, please order 2 kits. The designs are cost-effective NFPA 79 solutions offering quick and easy installation..24 Low Voltage Products & Systems OAG_ Flange operated fusible and non-fusible disconnect ABB s solutions comply with NFPA79 requirements for Flange Operated Fusible and Non-fusible Switches. NFPA 79 requires main disconnecting means to be operable without the use of accessory tools or devices, independent of door position. This code also includes an interlocking provision to prevent the closing of disconnects while the enclosure door is open, unless an interlock is operated by a deliberate action. The flange operated disconnect are available as ridged shaft or flexible cable operated versions. The cable operated version allows you to install the disconnect switch virtually anywhere in the enclosure depending on the length of the cable. Cables are available in lengths up to 84 inches.

29 Special configurations Cable operated flange A Fusible For a complete assembly, please select one each of the following: Switch OS200J30 Fusible Handle Cable Lug kit Operating mechanism UL general purpose amp rating UL fuse type 600V 60 J OS60GJ J J OS00GJ30 OS00GJ J J OS200J30 OS200GJ J J L OS400J30-FC OES600J3-FC OES800L3-FC J CC J OS30FAJ2 OS30FACC2 OS60GJ30 OHFC_ Flange handles UL98; File #E04 For use with: OS30FA_2, OS60GJ2/30, OS00GJ30, OS200J30 Environmental rating NEMA, 3R, 2 NEMA 4, 4X OHFC2 OHFC4 OS400J30-FC, OES600J3-FC, OES800J3-FC NEMA 4, 4X K7FCH4 OXCL_ Flexible cables For use with: OS30FA_2, OS60GJ30/03, OS00GJ30/03, OS200J30/03 OS400J30-FC, OES600J3-FC, OES800J3-FC Cable length (inches) OXCL36 OXCL48 OXCL60 OXCL72 OXCL84 48 K7C K7C K7C K7C084 Operating mechanisms For use with: MKCS_ OS30FAJ2, OS30FACC2 OS60GJ2 OS60GJ30/03, OS00GJ30/03, OS200J30/03 OS400J30-FC - OES800J3-FC MKCS2 MKCS3 MKCS4 Included For 00 A and above. OS30FA_...60GJ_ come with internal lugs Rotate the OS_03 disconnect 80 degrees to mount on the operating mechanism Operating mechanism is included Low Voltage Products & Systems.25

30 Fusible Special configurations Cable operated flange A Terminal lug kits OZXA-200 For use with Wire size Wire type Description Lugs per kit OS00GJ_ #4 300 kcmil Cu/Al - 6 OZXA-24 OS200J_ #4 300 kcmil Cu/Al - 6 OZXA-200 OS400 #2-600 kcmil Cu/Al - 6 OZXA-400 OES600 - OES800 (2) #2-600 kcmil Cu/Al - 6 OZXA-27 Terminal shrouds OSS_L_ For use on Description For full protection order Weight (lbs.) OS00GJ_ Single Pole long type shroud, 3 pcs 2 kits 0.7 OSS60GGL/3 OS00GJ_ Single Pole short type shroud, 3 pcs 2 kits 0. OSS60GGS/3 OS200J_ Single Pole long type shroud, 3 pcs 2 kits 0.20 OSS200GL/3 OS200J_ Single Pole short type shroud, 3 pcs 2 kits 0.3 OSS200GS/3 OS400J_ 3 pole shroud, pc 2 kits 0.3 OSS403 OES600J_ 3 Pole (includes one shroud for line and load side) kit 0.3 OESA-ZX25 OES800J_ 3 Pole (includes one shroud for line and load side) kit 0.3 OESA-ZX25 OSS_S_ Door hardware NEMA 2 Item Safety door latch, 2 point, door less than 40 high Safety door latch, 3 point, door greater than 40 high KDH2R KDH3R OSS_03 OESA-ZX_.26 Low Voltage Products & Systems

31 switch accessories Non-fusible & fusible Accessories Non-fusible & fusible disconnect switch Accessories I ON Low Voltage Products & Systems.29

32 Accessories Standard handles & shafts 2 Selector Handle OHBS_ Pistol Handle OHB_J_ Pistol Handle YASDA-8 Stainless Steel Pistol Handle OHM_L_ OHBS5 OHBS2 Amperes Selector handles for use with.24 x.24" (6mm) OXS6X_shafts UL/NEMA Type IEC type Color Marking Defeatable Padlockable Weight (lbs) IP54 Black O/I & Off/On No No 0.09 OHBSAH 3 No Yes 0.2 OHBS3AH 3, 3R, 2 IP65 Black O/I & Off/On No Yes 0.6 OHBS2AJ 3 Yes Yes 0.6 OHBS2AJ 3 Pistol handles for use with.24 x.24" (6mm) OXP6X_ shafts UL/NEMA Type IEC type Color Marking Length in/mm Defeatable Padlockable Weight (lbs), 3R, 2 IP65 Black Recommended handles & shafts Shaft diameter O/I & Off/On Off/On/Test O/I & Off/On Recommended standard pistol handle length 2.6/65 2.6/65 3./80 Yes Yes Yes Maximum recommended shaft length x6 mm -.24 x.24" mm 430 mm 200 6x6 mm -.24 x.24" mm 290 mm x2 mm -.47 x.47" mm 535 mm x2 mm -.47 x.47" mm 535 mm Yes Yes Yes OHB65J6 OHB65J6T 4 OHB80J6, 3R, 2, 4, 4X IP66 Black O/I & Off/On 2.6/65 Yes Yes 0.29 OHB65L6 3./80 Yes Yes 0.30 OHB80L6, 3R, 2, 4, 4X IP66 36L Stainless steel O/I & Off/On 2.6/65 Yes Yes.60 OHM65L6, 3R, 2 IP65 Black w/ 36 stainless hasp O/I & Off/On 2.6/65 Yes Yes 0.3 OHB65J6EH, 3R, 2, 4, 4X IP66 Black w/ 36 stainless hasp O/I & Off/On 2.6/65 Yes Yes 0.3 OHB65L6EH Pistol handles for use with.47 x.47" (2mm) OXP2X_ shafts UL/NEMA Type IEC type, 3R, 2 IP65, 3R, 2, 4, 4X IP66 Black Color Marking Length in/mm Defeatable Padlockable Weight (lbs) 4.9/25 Yes Yes 0.39 OHB25J2 Black 5.7/45 Yes Yes 0.39 OHB45J2 Black 6.9/75 Yes Yes 0.4 OHB75J2 O/I & Off/On Black T-Handle 7.9/200 Yes Yes 0.88 OHB200J2P Black Steel Reinforced 0.8/274 Yes Yes. OHB274J2 Black Steel Reinforced 3/330 Yes Yes.28 OHB330J2 Black 5.7/45 Yes Yes 0.39 OHB45L2 Black 6.9/75 Yes Yes 0.4 OHB75L2 Black T-Handle O/I & Off/On 7.9/200 Yes Yes 0.88 OHB200L2P Black Steel Reinforced 0.8/274 Yes Yes. OHB274L2 Black Steel Reinforced 3/330 Yes Yes.28 OHB330L2, 3R, 2, 4, 4X IP65 Metal Off/On 8.7/220, 3R, 2, 4, 4X IP66 36L Stainless Steel O/I & Off/On No Yes.50 YASDA-8 4.9/25 Yes Yes.7 OHM25L2 6.9/75 Yes Yes.8 OHM75L2 0.8/275 Yes Yes 2. OHM275L2 T-Handle 7.9/200 Yes Yes 0.88 OHM200L2P, 3R, 2 IP65 Black w/ 36 stainless hasp O/I & Off/On, 3R, 2, 4, 4X IP66 Black w/ 36 stainless hasp O/I & Off/On 4.9/25 Yes Yes 0.44 OHB25J2EH 6.9/75 Yes Yes 0.76 OHB75J2EH 4.9/25 Yes Yes 0.44 OHB25L2EH 6.9/75 Yes Yes 0.76 OHB75L2EH Red/Yellow handles are available by substituting the OHB prefix with OHY. 2 All handles are plastic unless otherwise noted as metal or stainless steel. 3 Recommended for use only on OT6F_, 25F_, 40F_, 63F_ and 80F_. 4 TEST position is accessed by rotating the mechanism 45 degrees counterclockwise from OFF position. In TEST position, optional auxiliary contacts are actuated but the main/power contacts are not. Test handles are also available for other disconnect sizes. Please consult ABB for options available..30 Low Voltage Products & Systems

33 Standard handles & shafts Accessories Direct mount handle for non-fusible disconnects Shaft D Description For use on Color Padlockable Weight through handle Yes OT6-40F_ Black Yes 0.05 No Mounts directly on switch. OT63-80F_ Yes No No shaft necessary Black No Yes 0.05 OT30/60/00F_ Yes Yes catalog OHBS2 CXBY68989 OHBS2 CXBY68998 CXBY684/6/2M OT200 Black Yes Yes 0.22 OTV250EK OT400 Black Yes Yes 0.44 OTV400EK Up to 3 padlocks in OFF-position, OT600 Black Yes Yes 0.66 OTV800EK includes shaft and mechanism OT800 Black Yes Yes 0.30 OTV000EK OT200 Black Yes Yes 0.30 OTV000EK Mounts on 2 mm shaft OETL-NF _SW Metal No Yes 0.80 YASDA-34 Direct mount handle for fusible disconnects F For use on Description Marking Color Padlockable Weight (lbs) OS30 No shaft required O/I/Test Black Yes 0.0 OHBS5 OS60 - OS200 No shaft required O/I/Test Black Yes 0.30 OSV200BK OS400 No shaft required O/I/Test Black Yes 0.75 OSV400BK OS600-OS800 No shaft required O/I/Test Black Yes 2.43 OSV800DK OS200 No shaft required O/I/Test Black Yes 3.30 OSV250DK Selector handles for door mounted UL/NEMA Type IEC Type Color Defeatable Padlockable Weight (lbs) Snap-on mounting - for use on OT6FT3 - OT40FT3 IP54 Black No No 0.0 OHBSPH IP54 Black No Yes 0.3 OHBS3PH, 3R, 2 IP65 Black No Yes 0.7 OHBS2PJ Screw mounting - for use on OT6-00FT3. For OT30FT3, OT60FT3 and OT00FT3 use OH_2_ only IP54 Black No No 0. OHBSRH IP54 Black No Yes 0.4 OHBS3RH, 3R, 2 IP65 Black No Yes 0.8 OHBS2RJ 3 Position selector handles for double throw - for use with.24 x.24" (6mm) OXS6X_shafts UL/NEMA Type IEC Type Markings Color Defeatable Padlockable, 3R, 2 IP65 I/0/II, ON/OFF/ON Black Yes Yes 0.6 OHBS2AJE0 3 Position pistol handles for double throw UL/NEMA Type IEC Type Markings Color Defeatable Padlockable Weight (Lbs.) 6 mm 2 mm, 3R, 2 IP65 Black Yes Yes 0.29/0.33 OHB65J6E0 OHB45J2E0, 3R, 2, 4, 4X IP66 Black Yes Yes 0.29/ 0.33 OHB65L6E0 OHB45L2E0, 3R, 2 IP65 Black Yes Yes 0.30/0.37 OHB80J6E0 OHB75J2E0, 3R, 2, 4, 4X IP66 I/0/II, ON/OFF/ON Black Yes Yes 0.30/0.37 OHB80L6E0 OHB75L2E0, 3R, 2 IP65 Black Yes Yes 0.88 OHB200J2PE0, 3R, 2 IP65 Black Yes Yes. OHB274J2E0, 3R, 2, 4, 4X IP66 Black Yes Yes. OHB274L2E0 Direct mount handle for double throw For use on Description Marking Color Padlockable Weight (lbs) OT6...80F_C No shaft required Black No 0.03 OHBS3 OT30, 60, 00F_C No shaft required Black No 0.02 OHBS9 OT6...80F_C No shaft required Black Yes 0.05 OHBS2 OT30, 60, 00F_C No shaft required Black Yes 0.04 OHBS OT200U_C No shaft required O/I/Test Black Yes 0.0 OTV250ECK OT400U_C No shaft required O/I/Test Black Yes 0.30 OTV400ECK OT600U_C No shaft required O/I/Test Black Yes 0.75 OTV800ECK OT800U_C No shaft required O/I/Test Black Yes 2.43 OTV000ECK Weight (Lbs.) Red/Yellow handles are available by substituting the OHB prefix with OHY. All handles are plastic unless otherwise noted as metal or stainless steel. Suitable for 3 & 4 pole versions only. Not for use with 6 or 8 pole. Markings are on the disconnect, not on the handles. Low Voltage Products & Systems.3

34 Accessories Standard handles & shafts OXS6X for selector type handles OXP6X OXP2X_ for pistol type handles Shafts for use with selector handles.24 x.24" (6x6 mm) Shaft length (in/mm) OT6F3, OT25F3, OT40F3 Maximum Mounting Depth (inches) OT63F3, OT80F3 OH & OH_3_ OH_2_ OH & OH_3_ OH_2_ 3.3/ OXS6X85 4./ OXS6X05 4.7/ OXS6X20 5./ OXS6X30 7./ OXS6X80 9.8/ OXS6X250 3/ OXS6X330 Weight (lbs) Shafts for use with pistol handles.24 x.24" (6x6 mm) Shaft length (in/mm) Maximum Mounting Depth (inches) OT6F3 - OT40F3 OT63F3 - OT80F3 OT30F3/60F3/00F3 OT200 OS30 OS60G OS00G OS / OXP6X30 5.9/ OXP6X50 8.3/ OXP6X20.4/ OXP6X / OXP6X / OXP6X / OXP6X430 Weight (lbs) Shafts for use with pistol handles.47 x.47" (2x2 mm) Shaft length (in/mm) Maximum Mounting Depth (inches) OT400 OT600 OT800 - OT200 OETL-NF _SW OS400 OS600 - OS200.0/ OXP2X / OXP2X / OXP2X / OXP2X465 2./ OXP2X535 Weight (lbs) Mounting depth is distance from the outside of the door to the disconnect switch mounting plate. Shaft can be adjusted or cut to desired length..32 Low Voltage Products & Systems

35 Auxiliary contacts Accessories (N)7 L4 N N N PE OT6E3 I ON (N)8 T4 N N N PE O OFF OEA28 OAG_ Auxiliary contacts snap-on mounting Description For Use On Weight (lbs) AC Thermal amp rating AC rated voltage Form C, N.O. & N.C. OS OA4BC N.O. OT6-00F_ (right side), OT OS30-OS OAG0 OT6-00F_ (left side) OAG0 N.C. OT OS30-OS OA3G0 N.O. & N.C. OT6-00F3 (both sides) OA2G OS OSZ4 Module for auxiliary OT contacts 0. OEA28 OS60G-OS200 Auxiliary contacts front mounting Weight AC Thermal Description For Use On AC rated voltage (lbs) amp rating N.O. + N.C OZXK- 2 N.O. + 2 N.C OZXK-2 OETL-NF600SW 4 N.O. + 4 N.C OZXK-3 2 N.O OZXK-4 OETL-NF2000SW 4 N.O OZXK-5 8 N.O OZXK-6 OA2G Auxiliary contacts snap-on mounting for double throw Description For Use On Mounting & installation considerations Weight (lbs) AC Thermal amp rating AC rated voltage N.C. OT6-00F_C (left side) OAG0 N.O. OT6-00F_C (left side) OA7G0 N.O. & N.C. OT6-00F3C (both sides) OA2G N.C. OT6-00F_C (right side) OA8G0 N.O. OT6-00_C (right side), OT _C OAG0 N.C. OT _C OA3G0 Non-Fusible OT6-00F_ OT OAG0 ( N.O.) mounts on right side of switch only, 2 pcs max. OAG0 ( N.C.) mounts on left side of the disconnect only, 2 pcs max. OA2G ( N.O. & N.C.) mounts on left or right side of the disconnect, 2 pcs max. Not mountable on the side of 4th poles. Mounting to the left side of the disconnect with OEA28 module: max. 8 aux. contacts At least 4 auxiliary contact blocks mounting under the mechanisms. OZXK-_ Fusible OS30 OS60G-200 Form C contacts mount directly to switch, 2 pcs max. OAG0 ( N.O.) + OA3G0 ( N.C.) require module OSZ4 (mounts on the left side) Max. 6 OAG0 + OA3G0 contacts with module OSZ4 (mounts on the left side) Mounting to the left side of the disconnect with OEA28 module: max. 8 aux. contacts At least 4 auxiliary contact blocks mounting under the mechanisms. UL file #E835 Not mountable on the side of 4th poles. Low Voltage Products & Systems.33

36 Accessories Terminal lugs OZXA-24 OZXA-200 Terminal lugs For Use On Wire Size Wire Type Lugs/Kit Weight (lbs) OS00G #4-2/0 Cu/Al OZXA-24 #4-300 kcmil OZXA-200 OT200, OS200 #4-300 kcmil OZXA-200/3 Cu/Al (6) 4-6 AWG OZXA-206T #2-600 kcmil OZXA-400 OT400, OS400 #2-600 kcmil OZXA-400/3 Cu/Al (2) #4-300 kcmil OZXA-402 (6) #4-6 AWG OZXA-406 OT600, OS600, OS800 (2) #2-600 kcmil Cu/Al OZXA OZXA-800/3 OT800, OT200, OS200 (4) #2-600 kcmil Cu/Al OZXA OZXA-200/3 OETL-NF600_SW (4) #2-600 kcmil (4) #2-600 kcmil (8) 2/0 + (2) #2-600 kcmil 3 Cu/Al OZXA-28 OZXA-28/3 OZXA-32 OETL-NF2000_SW (8) #2-600 kcmil Cu/Al OZXA-28/2 OZXA-400 Terminal lug kits for double throw For Use On Wire Size Wire Type Lugs/Kit OT200_C #4-300kcmil Cu/Al OT400_C #2-600kcmil Cu/Al OT600_C (2) #2-600kcmil Cu/Al Weight (lbs) OZXA-200/9 OZXA-200/2 OZXA-400/9 OZXA-400/2 OZXA-800/9 OZXA-800/2 OT800_C (4) #2-600 kcmil Cu/Al OZXA-200/9 OZXA-200/2 Additional Terminal lug kits for flange operated OZXA-32 For Use On Wire Size Wire Type Lugs/Kit OETL-NF400-FC, OES400 #2-600 kcmil Cu/Al 6 OETL-NF600-FC, OES600 - OES800 (2) #2-600 kcmil Cu/Al 6 OETL-NF800-FC (2) #2-600 kcmil Cu/Al 6 OETL-NF200-FC (4) #2-600 kcmil Cu/Al 6 Weight (lbs) OZXA-26 OZXA-27 OZXA-30 OZXA-28 OZXA-27 OZXA-30 Lugs are integral to the disconnects OT6-00F_, OS30FA_ and OS60G_. No separate lug kit accessory is required. OZXA-206T is a kit that contains: lug OZXA-75 and terminal shroud OTS250GL/3, both for 3 poles. For top and bottom, order two OZXA-206T kits A load side distribution lug eliminates the need to purchase, install and wire a separate distribution block..34 Low Voltage Products & Systems

37 Terminal shrouds Accessories Terminal shrouds for non-fusible For full protection, order OTS40T3 OTS80T3 OTS25T3 OTS40T OTS80T OTS25T OTS_GL/_ OSS_GL/_ Description For Use On Double-throw Weight 3 pole shroud, pc For 4th poles, Single pole shroud, pc OT6-OT40 OT63-OT80 OT30-OT00 OTP_40F_ OTP_80F_ OTP_25F_ OTS40T3 OTS63T3 OTS25T3 OTS40T OTS63T OTS25T Single pole long shroud, 3 pcs 0.2 OTS250GL/3 OT200, 3 poles Single pole short shroud, 3 pcs 0.3 OTS250GS/3 2 kits 2 kits Single pole long shroud, 4 pcs 0.26 OTS250GL/4 OT200, 4 poles Single pole short shroud, 4 pcs 3.8 OTS250GS/4 3 pole shroud, pc 3 pole shroud, pc Terminal shrouds for fusible Description Single pole long shroud, 3 pcs Single pole short shroud, 3 pcs OT400 OT600 OT800 OT200 For Use On OS00G, 3 poles Single pole long shroud, 3 pcs OS200, 3 poles Single pole short shroud, 3 pcs Single pole long shroud, 4 pcs OS200, 4 poles Single pole short shroud, 4 pcs 3 pole shroud, pc OS400, 3 poles OS600, 3 poles 3 pole shroud, pc Weight (lbs) OTS403 OTS603 OTS803 OTS203 OSS60GGL/3 OSS60GGS/3 OSS200GL/3 OSS200GS/3 OSS200GL/4 OSS200GS/4 OSS403 OSS603 OS800, 3 poles 2 kits 0. OSS803 Single pole long shroud, 3 pcs 2.2 OSS250GL/3 OS200, 3 poles Single pole short shroud, 3 pcs 0.88 OSS250GS/3 Single pole long shroud, 4 pcs 2 kits 2.20 OSS250GL/4 Single pole short shroud, 4 pcs OS200, 4 poles.5 OSS250GS/4 2 kits 2 kits 2 kits 2 kits 2 kits For full protection order 2 kits 2 kits 2 kits 4 kits 4 kits - - OTS_GS/_ OSS_GS/_ OTS_03 OSS_03 Low Voltage Products & Systems.35 OT6 - OT00 disconnects are IP20 touchsafe as standard. Terminal shrouds provide an extra degree of protection. 2 For 4 pole shrouds, please consult ABB.

38 Accessories Additional poles OTP_40FP OTP_80FP Additional poles for non-fusible Power poles - Only one power pole per switch: mounts on left or right side of switch. Description For use on Weight Fourth Pole Late-break/ early-make OT6-40F3, left side OT6-40F3, right size OT63-80F3 OT30-60F3 (UL98) OT00F3 (UL98) OT6-40F3 OT63-80F3 OT30-60F3 (UL98) OT00F3 (UL98) AC Thermal amp rating AC rated voltage 600 OTPS40FPN OTPS40FPN2 OTPS80FP OTPS60FP OTPS25FP OTPL40FP OTPL80FP OTPL60FP OTPL25FP Terminal poles - Switch accepts one terminal pole per side: mounts on left or right side of switch Description For use on Weight AC Thermal AC rated amp rating voltage OT6-40F OTPN40FP Solid neutral OT63-80F3 OT30-60F3 (UL98) OTPN80FP OTPN60FP OT00F3 (UL98) OTPN25FP Detachable Neutral OT6-OT40F3 OT63-OT80F3 OT30-60F3 (UL98) OTPD40FP OTPD80FP OTPD60FP OT00F3 (UL98) OTPD25FP Ground Terminal OT6-OT40F3 OT63-OT80F3 OT30-60F3 (UL98) OT00F3 (UL98) OTPE40FP OTPE80FP OTPE60FP OTPE25FP OTP_25FP Additional poles for fusible Description Detachable neutral For use on OS30 OS60G OS00G Weight (lbs) AC Thermal amp rating AC rated voltage OESA-ZX7 OSZ OSZ2 OESA-ZX7 OSZ_ accept only one power pole or one terminal pole per side For double throw disconnect OT_F3C: always order two poles, one for each side of the disconnect Power pole for OT6-OT40F3C, order piece of OTPS40FPN and piece of OTPS40FPN2 For door mounted non-fusible disconnects OT_FT3, replace _FP_ by _FD_ in the catalogue Mounted on the side of the disconnect, on the base plate or on a DIN rail Mounted on the base plate or DIN rail.36 Low Voltage Products & Systems

39 Fuse monitors, carriers and mounting adapters Accessories Fuse monitors For Use With Rated Voltage Weight (lbs) OS Suitable for or 3 phase circuits. Includes N.O. and N.C. auxiliary contacts and red & green LED lights for indication OFM240 OFM600 OFM_ Crimp terminals for fuse monitor wires For Use With Crimp Terminal size (mm) Includes OS terminals OFMZX2 OS OFMZX4 Fuse carriers Description For Use on CC fuse carrier (Qty. ) J fuse carrier (Qty. ) Solid link carrier (Qty. ) OS30FACC_ OS30FAJ_ OS30_ OESAZD48 OESAZD28 OESAZD55 Fuse carriers OESAZD_ Shorting bars for fusible Description For Use On AC thermal amp rating AC rated voltage Dummy Fuse OS OESAZD54 Solid links: metal strap OS00 OS OESA-ZS36 OESA-ZK98 DIN rail mounting kit For Use With Weight (lbs) OS60-00G_ 0.44 OSGZD Low Voltage Products & Systems.37

40 Accessories Miscellaneous accessories Replacement parts Miscellaneous accessories Shaft accessories Accessory Type Description For Use On Weight Shaft Adapter Adapts one end of a 6mm shaft to 2mm (use with shaft extension coupler) 6mm shafts 0.20 OETL-ZK OETL-ZK OESAZX-67 OETL-ZX95 OHZX0 Shaft Extension Coupler Shaft Guide Joins two shafts together for applications where extended length is required Fits all pistol grip handles, mounts on the inside of the enclosure door with provided hardware 6mm shafts 2mm shafts OESA-ZX67 OETL-ZX95 pistol handles - OHZX0 Busbar connections Accessory Type Description For Use On Weight Busbar Connections Vertical, back or edgewise mounting OETL-NF _SW OETL-ZX5 OETL-ZX4 Locking accessories Accessory Type Description For Use On Weight Electrical Interlock = Coil Voltage Closed circuit principle for interlocking the switch movement. When the coil circuit is dead, A-types cannot be operated to O-position and L-types cannot be operated to ON- or OFFposition. Coil voltages 0VAC, 220 VAC, 24VDC, 48VDC, 60VDC, 0VDC, 220VDC, P - 5W U = Un (U = coil voltage, Un = nominal voltage) OETL-NF _SW 2.42 OETL-ZT80A OETL-ZT80L OETL-ZX5 OETLZX4 Replacement parts Accessory Type Description For Use On Metal collar Replaces original black knob for locking shaft in place OT6F-200, OS OTZS2 Set screw Set screw for use with knob or collar OT6F-200 OS FLSWM5X8AX Shaft set screw Shaft set screw, bag of 0 OT , OS OZX Terminal cover Covers terminal below fuse carrier OS30 CXBY672 Phase barrier OS200 CXBY68794 OS60GJ_ CXBY69058 Fuse covers OS00GJ_ CXBY69072 OETL-ZT80_ OTZS2 FLSWM5X8AX Vertical busbar is provided as standard on OETL-NF600 and OETL-NF2000 disconnects..38 Low Voltage Products & Systems

41 Conversion, transfer & bypass mechanisms Mechanical interlocks Accessories OTZW8 OESAZ-ZW2 OETL-ZW9 Conversion mechanisms Mechanism Type For use on Weight UL/Nema Type 6 or 8 pole mechanisms Double throw mechanisms Bypass mechanisms Mechanical interlock mechanisms OS30, 6 poles OS30, 8 poles OT6-00F_ OT200, OS OT , OS OT6-00F_ 2.20 OT200, OS , 3R, 2 -, 3R, 2, 3R, 2, 4, 4X, 3R, 2, 3R, 2, 4, 4X OWP6DS OWP6DS2 OTZW8 OESA-ZW2 OETL-ZW9 OESA-ZW OESA-ZWX OTZW25 OTZW25X OT , OS , 3R, 2, 4, 4X OETL-ZW2 OT6-00F_.54, 3R, 2, 3R, 2, 4, 4X OTZW7 OTZW7X OT200, OS , 3R, 2 OTZW26 OT , OS , 3R, 2, 4, 4X OETL-ZW33 OT6-00F_ OS OT , OS OETL-NF _SW OTZW24 OTZW0 OETL-ZW3 OETL-ZW5 I ON 6 or 8 pole 6 (8) pole mechanism allows two controlled by one handle to open or close simultaneously. Equipment required for a complete installation: One conversion mechanism Two disconnect (see page.) One handle (see page.30) Two shafts (see page.32) 2 POS. O POS. I SW. A O X SW. B O X X = Closed O = Open OTZW25 Transfer Transfer mechanism manually transfers between two power sources using two and a center OFF position. A 3-position handle is included. Shafts included. Equipment required for a complete installation: One conversion mechanism Two disconnect (see page..) 2 POS. I POS. O POS. II SW. A X O O SW. B O O X X = Closed O = Open OTZW7 Bypass Bypass mechanism operates three : Two in series and one changeover switch to allow power bypass. A 3-position handle is included. Shafts included.equipment required for a complete installation: One conversion mechanism Three disconnect (see page..) 2 POS. I POS. O POS. II SW. A O O X SW. B O O X SW. C X O O X = Closed O = Open OETL-ZW24 Mechanical interlock Mechanical interlock mechanism prevents both from being in the ON position at the same time. Equipment required for a complete installation: One conversion mechanism Two disconnect (see page.) Two handles (see page.30) Two shafts (see page.32) SW. A SW. B POS. I POS. I SW. A X O SW. B O X X = Closed O = Open OT6E3 OT32E3 can use a selector or pistol handle. All other sizes must use a pistol handle. 2 = Three poles Low Voltage Products & Systems.39

42 Accessories Notes.40 Low Voltage Products & Systems

43 Enclosed disconnect A Non-fusible A Fusible Enclosed Enclosed eot, NF, FC, FJ and FL products meet customer requirements in terms of safety, ease of installation, space savings and operational convenience. They are available in a wide range of amperage ratings: - eot from 6 to 00 A, UL98 - NF, FC, FJ and FL from 6 to 2000 A built to UL98 requirements - NF 350 A IEC rated Low Voltage Products & Systems.4

44 Enclosed General information Non-fusible, fusible & lockable Non-fusible Snap on accessories include additional poles, auxiliary contacts, etc. Enclosures available in plastic, metal, or stainless steel in NEMA, 3R, 2, 4X, 7 & 9 environmental categories Modern appearance Quick make, quick brake mechanism Heavy duty disconnect, 600VAC Extremely compact size Finger-proof construction. No hazardous exposed parts 3/4/6/8 pole constructions; transfer and by-pass available Fusible Snap on accessories include fuse monitors, auxiliary contacts, etc. Enclosures available in plastic, metal, or stainless steel in NEMA, 3R, 2, 4X, 7 & 9 environmental categories Modern appearance Quick make, quick brake mechanism Heavy duty disconnect, 600VAC, 200kA, Isc Extreme compact size as fuse carriers are decked above contacts Double contacts enabling feed from any direction and preventing back feed Finger-proof construction. No hazardous exposed parts 3/4/6/8 pole constructions; transfer and by-pass available Lockable Clear position indications: I-ON O-OFF Door interlocked when handle padlocked to OFF position Door interlocked when handle is in ON position. Door interlock can be defeated by authorized personnel. Pilot devices can be added Handle padlockable with up to three padlocks.42 Low Voltage Products & Systems

45 General information Non-fusible, A Fusible, A Enclosed NF range ratings, A, 600 V UL General purpose amp rating Single phase Maximum horsepower rating Three phase 20V 200V 240V 200V 208V 240V 480V 600V Wire size for terminal lugs For wire type Built according to (*) #8 8 Cu UL #8 8 Cu UL #8 8 Cu UL #4 Cu UL #4 Cu UL #4 4 Cu UL #4 4 Cu UL #8 /0 Cu UL #6 300 kcmil Cu UL #2 600 kcmil Cu UL (2) #2 600 kcmil Cu UL (2) #2 600 kcmil Cu/Al UL (4) #2 600 kcmil Cu/Al UL (4) #2 600 kcmil Cu/Al UL (8) #2 600 kcmil Cu/Al UL (8) #2 600 kcmil Cu/Al IEC (*) Assemblies are not UL listed, but built to meet UL requirements Handle ratings Style NEMA Color Marking Defeatable Padlockable suffix type S Selector,3R,2 Black O/I & OFF/ON Yes Yes OHBS2AJ S Selector,3R,2 Red/Yel O/I & OFF/ON Yes Yes OHYS2AJ P Pistol,3R,2 Black O/I & OFF/ON Yes Yes OHB65J6 P Pistol,3R,4,4X,2 Black O/I & OFF/ON Yes Yes OHB65L6 P Pistol,3R,2 Red/Yel O/I & OFF/ON Yes Yes OHY65J6 P Pistol,3R,4,4X,2 Red/Yel O/I & OFF/ON Yes Yes OHY65L6 BJ Selector,3R,2 Black O/I & OFF/ON Yes Yes OHBS2AJ YJ Selector,3R,2 Red/Yel O/I & OFF/ON Yes Yes OHYS2AJ B4 Pistol,3R,2 Black O/I & OFF/ON Yes Yes OHB45J2 B4 Pistol,3R,2 Black I/O/II Yes Yes OHB45J2E0 B4 Pistol,3R,4,4X,2 Black I/O/II Yes Yes OHB45L2E0 Y4 Pistol,3R,2 Red/Yel O/I & OFF/ON Yes Yes OHY45J2 B6 Pistol,3R,4,4X,2 Black O/I & OFF/ON Yes Yes OHB65L6 Y6 Pistol,3R,4,4X,2 Red/Yel O/I & OFF/ON Yes Yes OHY65L6 B7 Pistol,3R,4,4X,2 Black O/I & OFF/ON Yes Yes OHB75J2 B7 Pistol,3R,2 Black I/O/II Yes Yes OHB75J2E0 B7 Pistol,3R,4,4X,2 Black I/O/II Yes Yes OHB75L2E0 Y7 Pistol,3R,4,4X,2 Red/Yel O/I & OFF/ON Yes Yes OHY75L2 B8 Pistol,3R,4,4X,2 Black O/I & OFF/ON Yes Yes OHB80L6 B8 Pistol,3R,2 Black I/O/II Yes Yes OHB80J6E0 B8 Pistol,3R,4,4X,2 Black I/O/II Yes Yes OHB80L6E0 Y8 Pistol,3R,4,4X,2 Red/Yel O/I & OFF/ON Yes Yes OHY80L6 6 Pistol,3R,4,4X,2 Black I/O/II No Yes OHB74L2E0 8 Pistol,3R,4,4X,2 Metal O/I & OFF/ON No Yes YASDA-8 2 Pistol,3R,4,4X,2 Metal I/O/II No Yes YASDA-2 2 Pistol,3R,4,4X,2 Black I/O/II No Yes OHB274L2E0 Handles are for the eot range Handles are for double throw Low Voltage Products & Systems.43

46 Enclosed General information Fusible, A FC, FJ an FL range ratings UL general Maximum horsepower rating purpose Single phase Three phase Wire size for terminal lugs For wire type Built according to (*) amp rating 20V 200V 240V 200V 208V 240V 480V 600V #8 8 Cu CSA, UL #4 4 Cu CSA, UL #4 2/0 Cu/Al CSA, UL #6 300 kcmil Cu/Al CSA, UL #2 600 kcmil Cu/Al CSA, UL (2) #2 600 kcmil Cu/Al CSA, UL (2) #2 600 kcmil Cu/Al CSA, UL (*) Assemblies are not UL listed, but built to meet UL requirements Enclosed non-fusible, 3 poles, 6 to 00 A EOT 6 U 3 M - P Size and Amps 6 = 6 A 30 = 30 A 32 = 40 A 45 = 60 A 60 = 60 A 63 = 80 A 00 = 00 A Poles 3 Enclosure P = Plastic S = Stainless steel M = Sheet steel Enclosure type = Type 3 = Type 3R/2 4 = Type 4/4X Auxiliary contact [Blank] = None 0 = N.C. = N.O. Handle P = Pistol Black P = Pistol Red/Yellow S = Selector Black S = Selector Red/Yellow M = Stainless Steel Handle Enclosed non-fusible 200 to 350 A, fusible from 30 to 800 A and specialty configuration NF P B6 C Style NF - Non-fused ( A) FJ - Fused "J" type fuses ( A) FC -Fused "CC" type fuses (30 A) Amps Type = Type 3 = Type 3R/2 Poles = Type 4 7 = Type 7 and/or 9 X = Type 4X Stainless Steel P = Type 4X Plastic Configuration P = Standard T = Double Throw Handle Refer to previous page, Handle ratings table Custom versions or other versions of enclosed products are available upon request. Please, consult ABB. Revision Part designation keys are provided for reference only. Not all variations or configurations are available..44 Low Voltage Products & Systems

47 3 pole Non-fusible, A Enclosed NF32X-3PB6C EOT6U3P3-S EOT63U3M-P 6-80 A, 600 VAC, 3 poles, UL508 Selector handle UL general purpose amp rating Standard UL/NEMA Enclosure Type 3R/2 4/4X 3R/2 Plastic 6 UL508 EOT6U3M-S EOT6U3M3-S Not available EOT6U3P3-S 40 UL508 EOT32U3M-S EOT32U3M3-S with selector EOT32U3P3-S 60 UL508 EOT45U3M-S EOT45U3M3-S handles EOT45U3P3-S 80 UL508 EOT63U3M-S EOT63U3M3-S EOT63U3P3-P 6-00 A, 600 VAC, 3 poles, UL508 and UL98 Pistol handle UL general purpose amp rating Standard UL/NEMA Enclosure Type 3R/2 4 4X Stainless 4X Plastic 7 & 9 6 UL508 EOT6U3M-P EOT6U3M3-P - EOT6U3S4-P EOT6U3P4-P NF67-3P 40 UL508 EOT32U3M-P EOT32U3M3-P - EOT32U3S4-P EOT32U3P4-P NF327-3P 60 UL508 EOT45U3M-P EOT45U3M3-P - EOT45U3S4-P EOT45U3P4-P NF457-3P 80 UL98 EOT63U3M-P EOT63U3M3-P - EOT63U3S4-P EOT63U3P4-P NF637-3P 30 UL98 EOT30U3M-P EOT30U3M3-P - EOT30U3S4-P NF30P-3PB6C NF307-3P 60 UL98 EOT60U3M-P EOT60U3M3-P - EOT60U3S4-P NF60P-3PB6C NF607-3P 00 UL98 EOT00U3M-P EOT00U3M3-P - EOT00U3S4-P NF00P-3PB6B NF007-3P A, 600 VAC, 3 poles, built according to UL standards Pistol handle UL general purpose amp rating UL/NEMA Enclosure Type 3R/2 4 4X Stainless 4X Plastic 7 & NF200-3PB8B NF2003-3PB8B NF2004-3PB8B NF200X-3PB8B NF200P-3PB8B 400 NF400-3PB4B NF4003-3PB4B NF4004-3PB4B NF400X-3PB4B NF400P-3PB4B 600 NF600-3PB7B NF6003-3PB7B NF6004-3PB7B NF600X-3PB7B NF600P-3PB7B 800 NF800-3PB4A NF8003-3PB4A NF8004-3PB4A NF800X-3PB4A NF800P-3PB4A 200 NF200-3PB4A NF2003-3PB4A NF2004-3PB4A NF200X-3PB4A NF200P-3PB4A 600 NF600-3P8A NF6003-3P8A NF6004-3P8A NF600X-3P8A 2000 NF2000-3P8A NF P8A NF P8A NF2000X-3P8A 350 NF350-3P8A NF3503-3P8A NF3504-3P8A NF350X-3P8A NOTE: All enclosed are provided with a black handle; however, most handles can be substituted with a red and yellow handle if desired. EXAMPLE: A red/yellow selector handle for an EOT6U3M-S can be substituted for the black selector handle by using the "S" suffix instead of the "S" sufix, new catalog #EOT6U3M-S. NF_ disconnects are not UL listed, but built to meet UL requirements IEC rated only Low Voltage Products & Systems.45

48 Enclosed 6 pole Non-fusible, A A, 600 VAC, 6 poles Pistol handle UL general purpose amp rating UL/NEMA Enclosure Type 3R/2 4 4X Stainless 4X Plastic 7 6 NF6-6PB6C NF63-6PB6C NF64-6PB6A NF6X-6PB6C NF6P-6PB6A NF67-6P 25 NF25-6PB6C NF253-6PB6C NF254-6PB6A NF25X-6PB6C NF25P-6PB6A NF257-6P 40 NF32-6PB6C NF323-6PB6C NF324-6PB6A NF32X-6PB6C NF32P-6PB6A NF327-6P 60 NF45-6PB6B NF453-6PB6B NF454-6PB6B NF45X-6PB6B NF45P-6PB6B NF457-6P 80 NF63-6PB6A NF633-6PB6A NF634-6PB6A NF63X-6PB6A NF63P-6PB6A NF637-6P 30 NF30-6PB6B NF303-6PB6B NF304-6PB6B NF30X-6PB6B NF30P-6PB6B 60 NF60-6PB6C NF603-6PB6B NF604-6PB6B NF60X-6PB6B NF60P-6PB6B 00 NF00-6PB6B NF003-6PB6B NF004-6PB6B NF00X-6PB6B NF00P-6PB6B 200 NF200-6PB4B NF2003-6PB4B NF2004-6PB4B NF200X-6PB4B NF200P-6PB4B 400 NF400-6PB8B NF4003-6PB8B NF4004-6PB8B NF400X-6P8B NF400P-6P8B 600 NF600-6PB8B NF6003-6PB8B NF6004-6PB8B NF600X-6P8B NF600P-6P8B 800 NF800-6PB8A NF8003-6PB4A NF8004-6PB4A NF800X-6P8A NF800P-6P8A 200 NF200-6P8A NF2003-6PB4A NF2004-6P8A NF200X-6P8A NF200P-6P8A A, 600 VAC, 3 poles, double throw Pistol handle UL general purpose amp rating UL/NEMA Enclosure Type 3R/2 4 4X Stainless 4X Plastic 6 NF6-3TB8C NF63-3TB8C NF64-3TB8C NF6X-3TB8C NF6P-3TB8A 25 NF25-3TB8C NF253-3TB8C NF254-3TB8C NF25X-3TB8C NF25P-3TB8A 40 NF32-3TB8C NF323-3TB8C NF324-3TB8C NF32X-3TB8C NF32P-3TB8A 60 NF45-3TB8B NF453-3TB8B NF454-3TB8B NF45X-3TB8B NF45P-3TB8B 80 NF63-3TB8A NF633-3TB8A NF634-3TB8A NF63X-3TB8A NF63P-3TB8A 30 NF30-3TB8B NF303-3TB8B NF304-3TB8B NF30X-3TB8B NF30P-3TB8B 60 NF60-3TB8B NF603-3TB8B NF604-3TB8B NF60X-3TB8B NF60P-3TB8B 00 NF00-3TB8B NF003-3TB8B NF004-3TB8B NF00X-3TB8B NF00P-3TB8B 200 NF200-3TB4B NF2003-3TB4B NF2004-3TB4B NF200X-3TB4B NF200P-3TB4B 400 NF400-3TB4B NF4003-3TB4B NF4004-3TB4B NF400X-3TB4B NF400P-3TB4B 600 NF600-3TB4A NF6003-3TB4B NF6004-3TB4A NF600X-3TB4A NF600P-3TB4A 800 NF800-3TB4A NF8003-3TB4A NF8004-3TB4A NF800X-3TB4A NF800P-3TB4A 200 NF200-3TB4A NF2003-3TB4A NF2004-3TB4A NF200X-3TB4A NF200P-3TB4A NF_ disconnects are not UL listed, but built to meet UL requirements.46 Low Voltage Products & Systems

49 3 Pole Fusible, A Enclosed FJ30X-3PB6B 3 pole, 600V, A Pistol handle UL general purpose amp rating Fuse Type UL/NEMA Enclosure Type 3R/2 4 4X Stainless 4X Plastic 30 J FJ30-3PB6B FJ303-3PB6B FJ304-3PB6B FJ30X-3PB6B FJ30P-3PB6B 30 CC FC30-3PB6B FC303-3PB6B FC304-3PB6B FC30X-3PB6B FC30P-3PB6B 60 J FJ60-3PB6B FJ603-3PB6B FJ604-3PB8B FJ60X-3PB8B FJ60P-3PB8B 00 J FJ00-3PB8B FJ003-3PB8B FJ004-3PB8B FJ00X-3PB8B FJ00P-3PB8B 200 J FJ200-3PB8C FJ2003-3PB8C FJ2004-3PB8C FJ200X-3PB8C FJ200P-3PB8C 400 J FJ400-3PB4C FJ4003-3PB4C FJ4004-3PB4C FJ400X-3PB4C FJ400P-3PB4C 600 J FJ600-3PB7C FJ6003-3PB7C FJ6004-3PB7C FJ600X-3PB7C FJ600P-3PB7C 800 L FL800-3PB4B FL8003-3PB4B FL8004-3PB4B FL800X-3PB4B FL800P-3PB4 Assemblies are not UL listed, but built to meet UL requirements Low Voltage Products & Systems.47

50 Enclosed Accessories Non -fusible OAG0 Auxiliary contacts For use on: 6 00 A A A Contact configuratio N.O. OAG0 N.C. OAG0 N.O. & N.C. OA2G N.O. OAG0 N.C. OA3G0 N.O. & N.C. OZXK- 2 N.O. & 2 N.C. OZXK-2 OZXK-_ Accessories For use on: Description Installation suffix code EOT6, 32 Neutral or isolated ground block N or G EOT45, 63 Neutral or isolated ground block N or G EOT30, 60, 00 Neutral or isolated ground block N or G NF A Neutral block N NF A Neutral block N NF A Service entrance, 3 wire U NF A Service entrance, 4 wire V Accessories Fusible Auxiliary contacts For use on: Contact configuration 30A N.O. + N. C. OA4BC N.O. OAG0 N.C. OA3G0 OAG0 OA4BC Accessories For use on: Description Installation suffix code 30A Neutral block N 60A 00A Neutral block N 200A 400A Neutral block N 600A 800A Neutral block N 30A 200A Service entrance, 3 wire U Service entrance, 4 wire V 400A 800A Service entrance, 3 wire U Service entrance, 4 wire V.48 Low Voltage Products & Systems

51 Technical data Approximate dimensions Technical data Selecting disconnects for motor applications per NEC Article 430 of the US National Electric Code includes two methods for properly sizing motor disconnects:. Single motor application A properly sized disconnect switch for a single motor will: a) have an ampere rating greater than or equal to 5 percent of the rated motor full load current; or, b) have a HP rating greater than or equal to the rated motor HP (at applied voltage) if the disconnect switch under consideration is HP rated. 2. Combination load application A properly sized disconnect switch for a combination load will be selected by adding all the simultaneous individual loads in the circuit under consideration. Using motor nameplate information, load information, and tables from section 430 of the NEC, determine one equivalent full load current, one equivalent locked rotor current and equivalent HP rating. Select a disconnect switch using equivalent current and/or housepower ratings of the combined load. Use of UL98 & UL508 s According to NEC Article 430 To supply UL98 Feeder Circuit Motor feeder Motor feeder short circuit and ground fault protection Motor disconnecting means (NEC ) UL98 Non-Fusible Switches OT30F, OT60F OT00F OT200, OT400, OT600, OT800, OT200 OETL-NF600 thru OETL-NF2000 UL98 Fusible Switches OS30, OS60G, OS00G, OS200, OS400, OS600 OS800, OS200 Motor branch-circuit short-circuit protection (NEC ) Typical control panel Motor controller (NEC ) UL508 Branch Circuit Motor overload protection (NEC ) OSHA Lockout/tagout disconnect (NEC ) OL UL508 Non-Fusible Switches OT6F, OT25F, OT40F, OT63F, OT80F (UL98 can also be applied) Motor M Low Voltage Products & Systems.49

52 Technical data Technical data OT6 00F_ UL & CSA UL & CSA 3 pole OT6F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT00F3 Approvals 3 pole UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 4 pole UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC General purpose amp rating -40 to 40 C pf = A Max. operating voltage V Max. horsepower rating/motor FLA current pf = Three phase 240V HP/A 5/ /22 0/28 5/42 20/54 0/28 20/54 30/80 480V HP/A 0/4 5/2 20/27 30/40 40/52 20/27 40/52 50/65 600V HP/A 0/ 20/22 25/27 30/32 40/4 30/32 40/4 50/4 Single phase 20V HP/A /6.5/20 2/24 2/24 2/24 5/56 240V HP/A 2/2 3/7 5/28 7.5/40 0/50 5/68 Fuse type CC ka 0, , , Fuse type J ka 0, 200 0, 00 0, 200 0, 00 0, 200 0, Fuse type T ka 0, 200 0, 00 0, 200 0, 00 0, 200 0, Fuse type RK ka Fuse type RK5 ka Fuse type L ka Fuse type H ka 5 5 Maximum fuse size A cycle short circuit current withstand rating ka Endurances 480V HP/A 5/4 7.5/2 0/26 5/34 20/44 25/55 600V HP/A 7.5/6 0/20 5/27 5/27 20/385 20/35 Short circuit rating with fuse - 480/600 V Min. Electrical endurance, pf = operation cycles Physical characteristics Weight, 3 pole lb pole lb Dimension, 3 pole H in W in D in Shaft set screw tightening torque lb. in Shaft size square in.24 x x x x x x x x.24 mm 6 x 6 6 x 6 6 x 6 6 x 6 6 x 6 6 x 6 6 x 6 6 x 6 Switch operating torque for lb. in rotary 3 pole Terminal lug kits Not required Not required Not required Not required Not required Not required Not required Not required Wire range AWG #8 8 #8 8 #8 8 #4 4 #4 4 #4 4 #4 4 #8 /0 Torque: Wire tightening lb. in Lug mounting lb. in. Integral Integral Integral Integral Integral Integral Integral Integral Auxiliary contacts OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ NEMA ratings, AC A600 A600 A600 A600 A600 A600 A600 A600 AC rated voltage VAC AC thermal rated current A AC maximum volt-ampere making VA AC maximum volt-ampere breaking VA NEMA ratings, DC R300 R300 R300 R300 R300 R300 R300 R300 DC rated voltage VDC DC thermal rated current A DC maximum make-break VA Torque: Wire tightening lb. in Wire range AWG #8 4 #8 4 #8 4 #8 4 #8 4 #8 4 #8 4 #8 4 UL Listed are also CSA Approved. For 00 and 200 ka ratings, mounting hardware must be used. Fuse size 70A for RK5 When protected by any Listed fuse or Listed circuit breaker whose current rating does not exceed the maximum thermal current rating of the switch..50 Low Voltage Products & Systems

53 Technical data OT200 OT200U_ OETL-NF UL & CSA UL & CSA 3 pole OT200U03 OT400U03 OT600U03 OT800U03 OT200U03 OETL-NF600 OETL-NF2000 Approvals 2 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 3 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 4 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC General purpose amp rating -40 to 40 C pf = A Max. operating voltage V Max. horsepower rating/max. motor FLA current, pf = V HP/A 75/2.0 25/ / /480 Three phase 480V HP/A 50/ / /55 500/ V HP/A 200/ / / /472 Single phase 20V HP/A 0/- 240V HP/A 0/- 0/- 50/- 480V HP/A 0/- 600V HP/A 0/- Maximum General Use, DC ratings 250VDC / 2 poles HP/A 40/200 50/400 50/600 Fuse type CC ka Fuse type J ka 200/00 00 /00 Fuse type T ka /00 /00 Fuse type RK ka Fuse type RK5 ka 00 / Fuse type L ka / Fuse type H ka Maximum fuse size A 200/ / cycle short circuit current withstand rating ka Endurances 25VDC / 2 poles HP/A 20/- 40/- 600VDC / 4 poles HP/A 50/00 50/200 -/200 Short circuit rating with fuse - 480/600 V Min. Electrical endurance, pf = operation cycles Technical data Physical characteristics Weight, 3 pole lb pole lb Dimension, 3 pole H in W in D in Shaft set screw tightening torque lb. in Shaft size square in.24 x x x x x x x x.47 Switch operating torque for rotary 3 pole mm 6 x 6 2 x 2 2 x 2 2 x 2 2 x 2 2 x 2 2 x 2 lb. in Terminal lug kits OZXA-200 OZXA-400 OZXA-800 OZXA-200 OZXA-200 OZXA-28 OZXA-28/2 Wire range AWG #4-300kcmil #2-600kcmil (2)#2-600kcmil (4)#2-600kcmil (4)#2-600kcmil (4)#2-600kcmil (8)#2-600kcmil Torque: Wire tightening lb. in Lug mounting lb. in Auxiliary contacts OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OZXK- OZXK- NEMA ratings, AC A600 A600 A600 A600 A600 A600 A600 AC rated voltage VAC AC thermal rated current A AC maximum volt-ampere making VA AC maximum volt-ampere breaking VA NEMA ratings, DC P600 P600 P600 P600 P600 P600 P600 DC rated voltage VDC DC thermal rated current A DC maximum make-break VA Torque: Wire tightening lb. in Wire range AWG #22 #4 #22 #4 #22 #4 #22 #4 #22 #4 #22 #4 #22 #4 UL Listed are also CSA Approved. W hen protected by any Listed fuse or Listed circuit breaker whose current rating does not exceed the maximum thermal current rating of the switch Multi-tap lug available, please see page.34. Low Voltage Products & Systems.5

54 Technical data Technical data OTDC A, VDC Technical data in accordance to UL508I for photovoltaic disconnect OTDC6...32U Suitable For Use in Photovoltaic Systems in Accordance With Article 690 of the NEC. Switch size OTDC6U OTDC25U OTDC32U UL Listed Standard UL 508i & IEC UL 508i & IEC UL 508i & IEC Rated ambient temperature C Rated current /poles in series 600 V One circuit 6/2 25/2 Two circuits 6/2x2 25/2x2 32/2x2 Three circuits 6/2x3 Short circuit rating ka, 600 V Protection type RK5 Fuse RK5 Fuse RK5 Fuse Wire range MCM 2-6 AWG 2-6 AWG 2-6 AWG Technical data in accordance to UL98B for photovoltaic disconnect OTDC U Suitable For Use in Photovoltaic Systems in Accordance With Article 690 of the NEC. ue OTDC00U OTDC80U OTDC200U OTDC250U OTDC320U OTDC400U OTDC600U Approvals Standard UL 98B & IEC UL 98B & IEC UL 98B & IEC UL 98B & IEC UL 98B & IEC UL 98B & IEC UL 98B & IEC Rated ambient temperature C Rated current /poles in series 000 V One circuit 00/2 200/2 250/2 320/2 400/2 600/2 Two circuits 00/2 80/2 250/2 320/2 400/2 500 V One circuit 250/3 320/3 400/3 Short circuit rating ka, 000 V Protection type Circuit breakercircuit breaker Circuit breaker Circuit breaker Circuit breaker Circuit breaker Circuit breaker Wire range MCM #4-300 #4-300 #4-300 #2 600 #2 600 #2 600 #2 600 IEC equivalent OTDC60E OTDC250E OTDC250E OTDC35E OTDC400E OTDC500E OTDC630E.56 Low Voltage Products & Systems

55 Technical data OS30 OS200 UL & CSA Technical data UL & CSA 3 pole OS30FA_2 OS60GJ2 OS00GJ03 OS200J03 OS400J03 OS600J03 OS800L03 OS200L03 Approvals 2 pole N/A UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 3 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 4 pole UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC Technical ratings -40 to 40 C General purpose amp rating A pf = Max operating voltage V Max horsepower rating/ Max motor FLA current pf = Three phase 240V HP/A 7.5/22.0 5/ / / / / / V HP/A 5/2.0 30/ / / / / / V HP/A 20/ / / / / / /472.0 Single phase 20V HP/A 2/ V HP/A 3/7.0 Short circuit rating with fuse ka UL Fuse size A UL Fuse type J/CC J J J J J L L Endurances Min. Electrical endurance, pf = operation cycles Physical characteristics Weight 3 pole lb pole lb Dimension 3 pole H in W in D in Shaft size square in.24 x x x x x x x x.47 mm 6 x 6 6 x 6 6 x 6 6 x 6 2 x 2 2 x 2 2 x 2 2 x 2 Switch operating torque lb. in for rotary 3 pole Terminal lug kits Integral Integral OZXA-24 OZXA-200 OZXA-400 OZXA-800 OZXA-800 OZXA-200 Wire range AWG #8 8 #4 4 #4 2/0 #4 300kcmil #2 600kcmil (2) #2 600 kcmil (2) #2 600 kcmil (4)#2-600kcmil Torque: Wire tightening lb. in Lug mounting lb. in. N/A N/A Auxiliary contacts OA4B_ OA/3G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ NEMA ratings, AC A600 A600 A600 A600 A600 A600 A600 A600 AC rated voltage VAC AC thermal rated current A AC maximum volt ampere making VA AC maximum volt ampere breaking VA NEMA ratings, DC P300 R300 R300 R300 P600 P600 P600 P600 DC rated voltage VDC DC thermal rated current A DC maximum make break current A Torque: Wire tightening lb. in Wire range AWG #22 4/#8 4 #8 4 #8 4 #8 4 #8 4 #8 4 #20 2 #20 2 The following UL Listed are also CSA approved. Low Voltage Products & Systems.57

56 Technical data Auxiliary contact timing diagrams OT6 OT00 Legend Main contacts ON I ON N.O. auxiliary contact N.C. auxiliary contact OFF O OFF OFF ON 0 I = Contacts in closed position = Contacts in closed position Contacts closing Contacts opening Main contacts close 4 Main contacts open 2 N.O. auxiliary contacts close 5 N.O. auxiliary contacts open 3 N.C. auxiliary contacts open 6 N.C. auxiliary contacts close OT6, OT25, OT40 Auxiliary contact Contact configuratio OAG0 N.O. OT6, OT25, OT40 OAG0 N.C. OA2G N.O. & N.C. OAG0 OAG0 OA2G Main contacts N.O. auxiliary contact N.C. auxiliary contact N.O. auxiliary contact N.C. auxiliary contact OFF ON 0 I = Contacts in closed position = Contacts in closed position OT63, OT80 Auxiliary contact Contact configuratio OAG0 N.O. OT63, OT80 OAG0 N.C. OA2G N.O. & N.C. OAG0 OAG0 OA2G Main contacts N.O. auxiliary contact N.C. auxiliary contact N.O. auxiliary contact N.C. auxiliary contact OFF ON 0 I = Contacts in closed position = Contacts in closed position OT30, OT60, OT00 Auxiliary contact Contact configuratio OAG0 N.O. OT30, OT60, OT00 OAG0 N.C. OA2G N.O. & N.C. Main contacts OAG0 N.O. auxiliary contact OAG0 N.C. auxiliary contact N.O. auxiliary contact OA2G N.C. auxiliary contact OFF ON 0 I = Contacts in closed position = Contacts in closed position.60 Low Voltage Products & Systems

57 Auxiliary contact timing diagrams OT200U - OT200U OETL-NF600 - OETL-NF2000 Technical data OT200U OT200U Auxiliary contact Contact configuratio OT200U - OT200U OAG0 OA3G0 N.O. N.C. ) OT only OETL-NF600 OETL-NF2000 Auxiliary contact Contact configuratio OETL-NF600 - OETL-NF2000 OZXK- OZXK-2 OZXK-3 N.O. & N.C. 2 N.O. & 2 N.C. 4 N.O. & 4 N.C Main contacts N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position OZXK- OZXK-2 OZXK-3 Low Voltage Products & Systems.6

58 Technical data Auxiliary contact timing diagrams OS30 Legend Main contacts N.O. auxiliary contact N.C. auxiliary contact a 0 I 0 I OFF O OFF ON I ON OFF ON 0 I = Contacts in closed position = Contacts in closed position Contacts closing Contacts opening Main contacts close 4 Main contacts open 2 N.O. auxiliary contacts close 5 N.O. auxiliary contacts open 3 N.C. auxiliary contacts open 6 N.C. auxiliary contacts close OS30 Auxiliary contact Contact configuration OA4BC N.O. & N.C. OS30_ OAG0 N.O. OA3G0 N.C Main contacts OA4BC OA4BC OAG0 OA3G0 N.O. auxiliary contact N.C. auxiliary contact N.O. auxiliary contact N.C. auxiliary contact Test.62 Low Voltage Products & Systems

59 Auxiliary contact timing diagrams OS60 - OS200 Technical data OS60 - OS200 ) OS200 only Low Voltage Products & Systems.63

60 Technical data NEMA Environmental ratings Introduction An enclosure is a surrounding case constructed to provide a degree of protection to personnel against accidental contact with the enclosed equipment and to provide a degree of protection to the enclosed equipment against specified environmental conditions. A brief description of the more common types of enclosures used by the electrical industry relating to their environmental capabilities follows. Refer to NEMA Standards Publication for more information regarding applications, features and design tests. Individual NEMA product Standards Publications or third party certification standards may contain additional requirements for product testing and performance. Definitions pertaining to nonhazardous locations Definitions pertaining to hazardous locations Type Enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling dirt. (NEMA Standard ) Type 4X Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. (NEMA Standard -0-79) Type 7 Enclosures are intended for indoor use in locations classified as Class I, G oups, A, B, C, or D, as defined in the National Electrical Code. (NFPA 70) Type 3R Enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet and damage from external ice formation. (NEMA Standard ) Type 2 Enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. (NEMA Standard ) Type 9 Enclosures are intended for indoor use in locations classified as Class II, G oups E, F, or G, as defined in the National Electrical Code. (NEMA Standard ) Legend Indoors Type 4 Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. (NEMA Standard ) Type 3 Enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil and noncorrosive coolant. (NEMA Standard ) X Outdoors Water Dirt/dust Corrosion.64 Low Voltage Products & Systems

61 IEC Environmental ratings Technical data IP ratings indicate the degree of protection against dust, liquids and impacts. The IP degrees of protection are defined by IEC To rate a device's degrees of protection, the letters IP are followed by up to three s. These s are defined as follows first second third protection against solid objects protection against liquids protection against mechanical impacts IP 0 no protection IP 0 no protection IP 0 no protection protected against solid objects over 50mm (e.g. accidental touch by hands.) protected against vertically falling rain or condensation impact 0,225 joule 50g falling from 5 cm 2 protected against solid objects over 2 mm (e.g. fingers 2 protected against direct sprays of water up to 5 from vertical 2 impact 0,375 joule 250g falling from5 cm 3 protected against solid objects over 2.5 mm (tools & wires) 3 protected against sprays to 60 from vertical 3 impact 0,50 joule 250g falling from 20cm 4 protected against solid objects over mm (small tools & small wires) 4 protected against water sprayed from all directions 5 impact 2,00 joule 500g falling from 40 cm 5 protected against dust (no harmful deposit) 5 protected against low pressure jets of water from all directions 7 impact 6,00 joule.5kg falling from 40 cm 6 totally protected against dust 6 protected from strong jets of water (e.g. for use on ship decks) 9 impact 20,00 joule 5 kg falling from 40 cm 7 protected against the effects of immersion between 5cm and m Low Voltage Products & Systems.65

62 Technical data Definition AC Alternating current Current that reverses its direction of flow twice per cycle Ambient temperature Temperature of the air surrounding the unit. Amp rating The basic unit of measurement for electric current (columbs / seconds). Conventional thermal current I th Value of the current the disconnect switch can withstand with poles in closed position, in free air for an eight hour duty, without the temperature rise of its various parts exceeding the limits specified by the standa ds. Cycle duration Total time of the on-load + off-load period. DC Direct current Current that flows in only one di ection. Electrical endurance Number of on-load operating cycles. IEC environmental protection type see page.48. Full load amp current FLA The current required by a motor to produce full-load torque at the motor's rated speed. Inductive load An electrical load characterized by having significant inrush (5 to 6 times FLA for typical design-b AC induction motors). kw Kilowatts (000 watts) Lockout/Tagout Means of removing power from electrical equipment during inspection, service or repair. Make / Break ON / OFF Mechanical endurance Number of off-load operating cycles. Poles in series Means of connection poles using wires or bus bars to increase breaking capacity of load. Power factor The relationship between working power and total power consumed. Power factor measures how effectively electrical power is being used. Rated insulation U i Voltage value which designates the unit and to which dielectric tests, clearance and creepage distances are referred. manufacturer and taking into account the rated operating voltage U e, the rated frequency, the rated duty, the utilization category, the electrical contact life and the type of protective enclosure. Rated operating voltage U e Voltage value to which utilization characteristics of the disconnect switch are referred, i.e. phase-tophase voltage in 3 phase circuits. Rated short circuit making capacity Icm The rated shortcircuit making capacity of a disconnect switch, a disconnector or a switch-disconnector is the value assigned to equipment at the rated operational voltage, frequency (if any) and specified powe - factor for AC or time constant for DC. It is expressed as the maximum prospective peak current under prescribed conditions. Rated short time withstand current Icw The rated shorttime withstand current of a disconnect switch, a disconnector or a switch-disconnector is the value that the equipment can carry without damage, under the test conditions specified in the relevant product standard. The value of the rated short-time withstand current shall be not less than twelve times the maximum rated operational current unless otherwise stated by manufacturer and the duration of the current shall be s. Resistive load An electrical load characterized by not having any significant inrush cur ent. Short circuit protection coordination Co-ordination types "" and "2" are defined in IEC Type coordination There has to be no discharge of parts beyond the enclosure. Damage to the contactor and the overload is acceptable. Type 2 coordination No damage to the overload relay or other parts has occurred, except that welding of contactor or starter contacts is permitted, if they are easily separated. Time constant Ratio of inductance to the resistance: L/R = mh/ohm = ms. Torque The force that produces rotation. It is commonly measured in pound-feet (lb-ft). Torque applies to such things as motor operations, handle rotations, wire tightening. NEMA environmental protection type see page.47. Volt The unit of electrical potential difference and electromotive force. Rated operating current I e Current value stated by the.66 Low Voltage Products & Systems

63 Approximate dimensions OT6 OT00 Dimensions [Inches] [Millimeters] OT6F3, OT25F3, OT40F3 base & DIN rail mounted switch DIA OT63F3, OT80F3 base & DIN rail mounted switch DIA OT30F3, OT60F3, OT00F3 base & DIN rail mounted switch DIA Low Voltage Products & Systems.67

64 Dimensions Approximate dimensions OT6 OT00 OT6FT3, OT25FT3, OT40FT3 door mounted switch MOUNTING HOLE DETAIL OT63FT3, OT80FT3 door mounted switch D D MOUNTING HOLE DETAIL OT30FT3, OT60FT3, OT00FT3 door mounted switch D D MOUNTING HOLE DETAIL Low Voltage Products & Systems

65 [Inches] Approximate dimensions OT6F6 OT00F6 6-pole Dimensions OT6, 25, 40F6 6 Pole DIA shaft depth mm DIN rail OT63, OT80F6 6 Pole DIA shaft depth mm DIN rail OT30, OT60, OT00F6 6 Pole DIA shaft depth mm DIN rail Low Voltage Products & Systems.69

66 Dimensions Approximate dimensions OT6 OT00F3C Double throw OT6, OT25, OT40F3C Double throw DIA shaft depth mm DIN rail OT45, OT63, OT80F3C Double throw DIA shaft depth mm DIN rail OT30, OT60, OT00F3C Double throw DIA shaft depth mm DIN rail Low Voltage Products & Systems

67 [Inches] Approximate dimensions OT200_ OT400_ Dimensions OT200U03 OT400U03 Low Voltage Products & Systems.7

68 Dimensions Approximate dimensions OT600U03 OT800U03 OT600U03 OT800U [53].57 [294] 2.76 [324] 3.5 [80] 3.78 [350].06 [27] 0.35 [9] 8.99 [482] 4.65 [372] 9.3 [232] 6.93 [76] 0.77 [20] 3.05 [78] 0.59 [5] 5.20 [32] 5.74 [46] 0.80 [20] 0.40 [0] 0.54 [4].97 [50].72 Low Voltage Products & Systems

69 Approximate dimensions OT200U03 OETL-NF600 Dimensions [Inches] Inches OT200U03 OETL-NF Inches [Millimeters] 0.55 DIA DIA DIA pole pole pole pole pole pole Low Voltage Products & Systems.73

70 Dimensions Approximate dimensions OETL-NF2000 OETL-NF DIA DIA DIA pole pole pole pole pole pole Low Voltage Products & Systems

71 Approximate dimensions OTDC switche s Dimen sions OTDC6...32US_, base or DIN rail mounted C A B 0.65 I - ON O - OFF.77 D Dimension [in] Number of poles A B C D Ø Inches [Millimeters] OTDC US02 Picture may not match the exact catalogue. Dimensios are correct. OTDC US/22 Picture may not match the exact catalogue. Dimensios are correct. OTDC00, 200U02 [mm/in] 02 A 80/3,5 B 5,5/4,55 OTDC00, 200U...22 [mm/in] 22 A 80/3,5 5/4,53 B 5,5/4,55 85,5/7,3 Low Voltage Products & Systems.75

72 Dimensions OTDC250/320/400US_ Picture may not match the exact catalogue. Dimensios are correct. Approximate dimensions OTDC OTDC250/320/400/600US_ Picture may not match the exact catalogue. Dimensios are correct [Millimeters] Inches OTDC250, 320, 400U_ OTDC250, 320, 400, 600U_ [mm/in] 02 A 9/7,84 A 208/8, [mm/in] 2 22 A 7/7,76 266/0,48 335/3,2 A 208/8, 277/0,9 346/63 OTDCKIT400B0 mm in 5 0,59 5 5, ,2 4,76 0,0 Ø2,5 30,8 6 0,24.74 Low Voltage Products & Systems

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible Non-fusible Disconnect Non-fusible disconnect 6A 350A, 600V Disconnect Non-fusible ABB SwitchLine includes 6 different amperage sizes from 6A to 350A. The basic construction provides flexibility, safety,

More information

+ + + OS400J03 + OXP12X280 + OHB145J12 + OZXA-24. UL general purpose amp rating. UL Fuse Type 600V Catalog number Catalog number Catalog number

+ + + OS400J03 + OXP12X280 + OHB145J12 + OZXA-24. UL general purpose amp rating. UL Fuse Type 600V Catalog number Catalog number Catalog number Disconnect Base & DIN rail mounted 1200A For a complete assembly, please select one of each: 1 switch (page.22) 1 handle (page.) 1 shaft (page.32) 1 terminal lug kit (page.34) NOTE: For additional accessories,

More information

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web:  - disconnect A 1200A, 600VAC Disconnect Disconnect ABB PowerLine includes seven different amperage sizes from A to 1200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible Disconnect disconnect 1A 1A, 0V Disconnect ABB SwitchLine includes 1 different amperage sizes from 1A to 1A. The basic construction provides flexibility, safety, and high performance in an extremely compact

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible Disconnect disconnect 1A 1A, 0V Disconnect ABB SwitchLine includes 1 different amperage sizes from 1A to 1A. The basic construction provides flexibility, safety, and high performance in an extremely compact

More information

Fusible. Fusible disconnect switches 30A 800A, 600V. Disconnect switches. Fusible

Fusible. Fusible disconnect switches 30A 800A, 600V. Disconnect switches. Fusible disconnect A 800A, V ABB PowerLine includes seven different amperage sizes from A to 800A. All ABB fusible are designed to meet customer requirements in terms of high interrupting capacity and long electrical

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Disconnect switches Non-fusible Fusible Enclosed

Disconnect switches Non-fusible Fusible Enclosed Disconnect switches Non-fusible Fusible Enclosed Low voltage disconnect switches from ABB ABB is committed to offering high quality and innovative low voltage products. ABB s disconnect switch lines are

More information

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A Low Voltage Products Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A 7 Page Shaft operated Cable operated Amp.

More information

Kits 30A 800A, 600V, 3 pole 1 UL fuse class J, CC, T, L

Kits 30A 800A, 600V, 3 pole 1 UL fuse class J, CC, T, L Kits 30A 800A, 600V, 3 pole UL fuse class J, CC, T, L Each kit includes: three pole switch handle shaft terminal lug kit Kit handle shaft switch terminal lug kit2 Kits with selector handles UL UL general

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP

Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP Contact us ABB Oy Breakers and Switches P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions

More information

Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data

More information

Reliable in extreme conditions

Reliable in extreme conditions Protection and Connection OT Non-fusible Disconnect Switches 1600...2000 Amperes OT51GB 16-07 1SCC301023K0201 Reliable in extreme conditions Space saving Easy to install Suitable for heavy duty applications

More information

Low Voltage Products. Switches Switch-disconnectors OT and OETL

Low Voltage Products. Switches Switch-disconnectors OT and OETL Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC lth /A le /AC22A, 415V le /AC23A, 415V... OT16F OT63F OT100F OT160E OT25F OT80F OT125F OT40F 25 32 40 63 80 115 125

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview for Non- Disconnect Switches CDNF16 CDNF100A3 CDNF16A3, CDNF25A3, CDNF32A3 CDNF30A3, CDNF60A3, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF25A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF60A3 CDNF100A3

More information

Breakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Breakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data

More information

Switches for PV applications Switch-disconnectors OTDC and OTDCP. Contact us

Switches for PV applications Switch-disconnectors OTDC and OTDCP. Contact us Contact us ABB Oy Breakers and Switches P.O. Box 622 FI65101 Vaasa, Finland Phone: 358 10 22 11 Fax: 358 10 22 45708 EMail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions are

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

Switch-disconnectors OT , OETL 3150

Switch-disconnectors OT , OETL 3150 Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated

More information

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Breakers and Switches. Switches Switch-disconnectors OT and OTM Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection -disconnectors OTDC and OTDCP for photovoltaic applications -disconnectors OTDC and OTDCP for photovoltaic applications DC swi-disconnectors Premium performance for DC applications

More information

Disconnect Switches Compact, Heavy-Duty

Disconnect Switches Compact, Heavy-Duty Table of Contents Bussmann Disconnect Switches Compact, Heavy-Duty Table of Contents Fusible Disconnect Switches...Page 2 Fusible Non-Fusible Disconnect Switches...Page 29 Non-Fused Enclosed Fusible Disconnect

More information

Overview for Fusible Disconnect Switches

Overview for Fusible Disconnect Switches Overview for Fusible Disconnect Switches CFD30CC3 FD800L3 CFD30AJ3 CFD60J3 CFD100J3 FD400J3 FD600J3 FD800L3 number 3 pole CFD30ACC3 CFD30AJ3 CFD60J3 CFD100J3 CFD200J03 FD400J3 FD600J3 FD800L3 General purpose

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview CDNF16 CDNF100A3 CDNF16A3,, CDNF32A3 CDNF30A3,, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF100A3 General purpose amp rating A 16 25 40 60 80 30 60 100 2 pole

More information

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201 Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E

More information

1200A 3150A Non-fusible disconnect switches

1200A 3150A Non-fusible disconnect switches Non-fusible disconnect switches FF Index Switches...40 Pistol handles....40 Shafts....40 Twisted shafts....4 : 90 Angle kit....42 Auxiliary contacts....4 Busbar connections....4 Handle support bracket....42

More information

Breakers and Switches. Switches Change-over and transfer switches

Breakers and Switches. Switches Change-over and transfer switches Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic

More information

Switch-disconnectors OTDC and OTDCP

Switch-disconnectors OTDC and OTDCP PROTECTION AND CONNECTION Switch-disconnectors OTDC and OTDCP Switches for photovoltaic and ESS applications Designed for harsh environments Compact and modular design Reduced power losses Switch-disconnectors

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

FJ303-3PB6B. 4X Plastic 12. Catalog List Catalog List number price number price

FJ303-3PB6B. 4X Plastic 12. Catalog List Catalog List number price number price 3 Pole 30A 800A 7 FJ30X-3P02A 3 Pole, 0V, 30A 800A UL 98 UL 98 UL general purpose amp rating 3 Pole, 0V, 30A 800A UL general purpose amp rating Fuse X Stainless Catalog List Catalog List Catalog List Catalog

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview for on- Disconnect Switches CDF16 CDF100A3 CDF16A3, CDF25A3, CDF32A3 CDF30A3, CDF60A3, CDF100A3 CDF160 3 pole CDF16A3 CDF25A3 CDF32A3 CDF45A3 CDF63A3 CDF30A3 CDF60A3 CDF100A3 General purpose amp

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Low Voltage Switches. Fusegear Switch fuses OS and OSM

Low Voltage Switches. Fusegear Switch fuses OS and OSM Low Voltage Switches Fusegear Switch fuses OS and OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 DIN-

More information

Switch fuses OS , OSM

Switch fuses OS , OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 16 Ordering information, manual operation 16 Front operated switch fuses OS 25 Side operated switch fuses

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

60A 100A for Fusible Disconnect Switches

60A 100A for Fusible Disconnect Switches 60A 100A for Fusible Disconnect Switches Fuse Class J CFD60J3 CFD100J3 BDH58,60 BDH59,61 BDS CFD60J3 + BDS210 + BDH58 60 100 Amp switches, 600V Maximum horsepower rating general Fuse purpose type Three

More information

Disconnect Switches. Bussmann. Bussmann Information Fax ~ Bussmann Worldwide Web ~

Disconnect Switches. Bussmann. Bussmann Information Fax ~ Bussmann Worldwide Web ~ Page Selection Guide Fusible 2 Non-Fusible 3 Handles 4 Disconnect Switches Fusible (30-800A) Features 5-6 Components 7 Accessories 8 Non-Fusible (16-3150A) Features 9 Components 10-14 Accessories 15 Mounting

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

footprint of traditional fusible switches

footprint of traditional fusible switches Disconnect switches Contents Section page Description Compact Circuit Protector (CCP) disconnect switches Class CC, UL supplemental and IEC 0x38mm (CCP) -3 Class CF CUBEFuse (CCP-CF) 4-5 Compact Circuit

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

34OSM_ rev. C / 1SCC311029M0203. Motorized switch fuses OSM_ Installation and operating instructions

34OSM_ rev. C / 1SCC311029M0203. Motorized switch fuses OSM_ Installation and operating instructions 3OS_ rev. C / SCC309003 otorized switch fuses OS_ Installation and operating instructions Contents Installation and operating instructions, OS_ Contents. Introduction.... Use of symbols.... Explanations

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information

Low Voltage Switches. Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM

Low Voltage Switches. Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM Low Voltage Switches Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM Motorized switches OTM 60...2500, OSM 2...250 Contents Product overview 6 Features 8 Technical data 6

More information

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application Bussmann Open and Enclosed Rotary Disconnect Switches Exceptional Breadth and Availability f Your Application 2 Visit us on the web at www.cooperbussmann.com/disconnects Table of Contents Compact Circuit

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

UL 98 Fusible Disconnect Switches

UL 98 Fusible Disconnect Switches UL 98 Fusible isconnect witches ICONNECT WITCHE Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are service entrance devices capable of fully

More information

ABB Control. Technical Brochure. Low Voltage Apparatus. SwitchLine Load Break Switches/ Switch-Disconnectors A, 690 V

ABB Control. Technical Brochure. Low Voltage Apparatus. SwitchLine Load Break Switches/ Switch-Disconnectors A, 690 V Technical Brochure Low Voltage Apparatus SwitchLine Load Break Switches/ Switch-Disconnectors Brochure OETL 1A GB 98-11 16...160 A, 690 V 200...3150 A, 1000 V 95MDN5573 95MDN5523 ABB Control SwitchLine

More information

Low Voltage Switches. Switches Switch fuses OS A Gamma series

Low Voltage Switches. Switches Switch fuses OS A Gamma series Low Voltage Switches Switches Switch fuses OS32...1 Gaa series Switch fuses for extreme conditions - OS 32 1 Gaa series Numerous applications require switch fuses that can withstand extreme conditions.

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information

More information

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR The safest way to switch power on and off in your industrial control panels. Your problem: You

More information

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

Rotary Disconnect Switches, Bulletin 194R

Rotary Disconnect Switches, Bulletin 194R ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information