SOLAR THERMAL Forced circulation solar thermal system with selective flat plate collectors SELECTIVE SLIM
|
|
- Charlotte Harper
- 5 years ago
- Views:
Transcription
1 Forced circulation solar thermal system with selective flat plate collectors SEETIVE SIM SEETIVE 2.0 V flat plate collector vertical arrangement SEETIVE 2.0 O flat plate collector horizontal arrangement SEETIVE 2.5 V flat plate collector vertical arrangement SEETIVE 2.5 O flat plate collector horizontal arrangement Dimensions and overall dimensions SEETIVE solar collector M G F SEETIVE M 880 G 22 F 50 valori espressi in SEETIVE Technical table for flat solar collector SEETIVE U.M. SEETIVE 2.0 kg 43,0 DESRIPTION eight ase color ase material Insulation thickness Glass Net absorbent surface Opening area Total collector area bsorbent plate material Surface treatment Efficiency (opening) bsorption Issuance Recoended flow / panel ollector water capacity Maximum working pressure Stagnation temperature η 0 % % l/h l,76,789,998 0,762 0,6 0 rown R 807 luminum 45 Extra clear - Tempered luminum Selective TITN (titanium oxide) 95 4,7 92 SEETIVE ,0 2,304 2,345 2,573 0, ,0
2 Forced circulation solar thermal system with vacuum tube collectors VUUM Dimensions and overall VUUM 8 P 500 VUUM P 500 VUUM 2 P 500 VUUM 4 P 500 VUUM 6 P 500 VUUM 8 P 500 VUUM 20 P Dimensions and overall dimensions of vacuum tube collector VUUM 8 20 P 500 P Ø47 Ø58 External glass tube Inner glass tube bsorber opper circuit N. Tubes Gross rea,45,82 2,8 2, P eight Kg 26,6 33,8 4,0 48,2 6 2, ,4 8 3, ,0 20 3, ,2 Technical data table for collector VUUM 8 20 P 500 DESRIPTION Optical efficiency (00 / ) eat loss I a eat loss II a2 IM Incidence ngle Modifier Thermal capacity Flow bsorbance ydraulic connections Min / max angle of installation Stagnation temperature iquid content Transmittance Max pressure U.M. % / K / K 2 K (50 ) KJ/ K l/ min l VUUM 8 20 P 500 7,9,063 0,005,09 39,93 0,6 -,0 0,95 4 x Ø ,3 (for a tube) 0,9 6
3 Solar system with natural circulation for the production of SKY domestic hot water Template SKY 200 Flat roof SKY 200 Inclined roof SKY 300 Flat roof SKY 300 Inclined roof Dimensions and dimensions SKY Ø SKY 200 SKY 300 Values in Technical data table SKY DESRIPTION Gross area of the solar field Net area of the solar field Kettle capacity Diameter ydraulic connections Electrical resistance attack Polyurethane insulation Max working pressure Max. Temperature Sanitary exchanger Sanitary water connections Sanitary water content Exchange surface Empty weight U.M. l l Kg SKY 200 2,58 2, ,0 540 / ISI 36 /2 7 3 SKY 300 3,43 3, ,0 2
4 Solar storage system with natural circulation for the production of hot water OMPT OMPT 0 OMPT 50 OMPT Dimensions and dimensions OMPT P OMPT P OMPT OMPT 200 Values in Technical data table OMPT DESRIPTION Total collector area Opening area Insulating D capacity Kettle tubes material Thickness of kettles tubes Electric antifreeze heater Electric resistance (optional) ater inlet / outlet Max working pressure eight U.M. l Kg OMPT 0 0,99 0, ,0 3 OMPT 50,96,78 Expanded Polystyrene 48 Inox, ,5 OMPT 200 2,38 2,3 84 8,0
5 -way solar station UNIT SE irculation unit 2 2 l / min with 3/4 M connections ilo Yonos Para ST 25/7 circulator with cable gland, flow regulator with valves plant loading and unloading, DN20 3-way flanged ball valve with m non-return valve equipped with thermometer holder handle, 6 safety group with pressure gauge Ø 50 0 with 3/4 M connection for expansion vessel. Preformed shell EPP insulation box and wall mounting bracket. UNIT SE with electronic circulator way solar station UNIT 2 PUS irculation unit 2 2 l / min with 3/4 M. supply and return connections ilo Yonos Para ST 25/7 circulator with cable gland, flow regulator with valves plant loading and unloading, DN20 3-way flanged ball valve with m non-return valve equipped with thermometer holder handle, 6 safety group with pressure gauge Ø 50 0 with 3/4 M connection for expansion vessel. DN20 flanged ball valve with non-return valve m provided with thermometer holder handle, deaerator with manual vent valve, connecting pipe and connection preformed shell EPP insulation box and wall mounting bracket. UNIT 2 SE with electronic circulator way solar station UNIT 2 X PUS irculation unit l / min with /4 M flow and return connections, complete with circulator ilo Stratos Para ST 25 / -8 with cable gland, flow controller, valve a ball DN25 with check valve 8 m provided with handle for thermometer, T fitting for safety group, safety group 6 with pressure gauge Ø 50 0 with 3/4 connection M for expansion vessel, T connection with probe hole Ø 6, DN25 ball valve with non-return valve m provided with thermometer holder handle, connection pipe and connection, preformed shell EPP insulation box and wall mounting bracket. UNIT 3 SE with electronic circulator Technical data table UNIT 2 PUS - UNIT 2 X PUS DESRIPTION Max working temperature short period 20 s continuous temperature Max working pressure Safety valve calibration Range of flow regulation Gauge scale Thermometer scale External connections irculator model ody Power supply Max power Max. Temperature Degree of protection U.M. l/m UNIT 2 PUS 2 2 M ilo Yonos Para 25/ ast iron 230V//50z IP X4D UNIT 2 X PUS /4 M ilo Stratos Para 25/-8 30
6 ONTRO MUTI 06 S solar control unit Digital solar control unit ONTRO MUTI 06 S equipped with 3 DT-PUS probes for the control of systems with collectors solar thermal systems with forced circulation. - n. 3 relay outputs - n. PM output - n. 0-V output - n. 6 preset functional patterns Format x P x Protection Supply bsorption umidity Operating temperature Probes Probes type % n. 56 x 47 x 8 IP V//50z Pt ONTRO MUTI 06 S entralina solare ONTRO MUTI 09 S Digital solar control unit ONTRO MUTI 09 S equipped with 3 DT-PUS probes for the control of systems with collectors solar thermal systems with forced circulation. - n. relay outputs - n. PM/ 0-V - n. 6 preset functional patterns Format x P x Protection Supply bsorption umidity Operating temperature Probes Probes type Pixel n. 86 x 45 x 5 IP V//50z 2 28 x Pt 00 ONTRO MUTI ONTRO MUTI 25 S solar control unit Digital solar control unit ONTRO MUTI 09 equipped with 3 DT-PUS probes for the control of systems with collectors solar thermal systems with forced circulation. - n. 2 relay output - n. PM / 0- V output - n. 25 preset functional schemes - Estimated energy produced - ntifreeze protection ONTRO MUTI 25 S Format x P x Protection Supply bsorption Display Operating temperature Probes Probes type Pixel n x 5 x IP V//50z 2,5 28 x Pt 00 5
7 Fixing systems on a pitched roof for SEETIVE manifolds Frames for inclined roofs complete with stainless steel fastening strips and junction between one frame and the other. Multiple frames must be made based on the number of panels. TV TV2 TV3 TV TV2 TV3 TO TO2 TO TO values in TV 2.0 Vertical arrangement for SEETIVE 2.0 V collector TV2 2.0 Vertical arrangement for 2 SEETIVE 2.0 V collectors TV3 2.0 Vertical arrangement for 3 SEETIVE 2.0 V collectors TV 2.5 Vertical arrangement for SEETIVE 2.5 V collector TV2 2.5 Vertical arrangement for 2 SEETIVE collectors 2.5 V TV3 2.5 Vertical arrangement for 3 SEETIVE collectors 2.5 V TO 2.0 orizontal arrangement for SEETIVE 2.0 O collector TO2 2.0 orizontal arrangement for 2 SEETIVE 2.0 O manifolds TO 2.5 orizontal arrangement for SEETIVE 2.5 O collector TO2 2.5 orizontal arrangement for 2 SEETIVE collectors For the mounting of a VUUM solar collector 2 fixing kits have to be provided. Fastening with strip* Fixing kit with sloping roof strip for VUUM series solar collectors, composed of two aluminum extrusions for connection at the head and foot of the solar collector and two 60 cm stainless steel multi-hole strips that can be used to connect the collector solar to the building structure under the roof covering. Screws and nuts included. Fixing with screw Fixing kit with screw on sloping roof for VUUM series solar collectors, composed of two aluminum extrusions for connection to the head and at the foot of the solar collector and two M2x350 wood thread screws for the connection of the solar collector to the load-bearing structure in wood under the roof covering. Screws and nuts included. Fastening with strip Fixing with screw TV VUUM S* TV VUUM V* * For the mounting of a VUUM solar collector 2 fixing kits have to be provided
8 Fixing systems on a pitched roof for OMPT manifolds Frame for inclined surface with tiles OMPT 0 OMPT OMPT 200 Values in TV OMPTTO Fixing systems on flat roofs for SEETIVE manifolds nchor frame on flat surfaces for forced circulation solar collectors SEETIVE model, complete with bracing for ensure adequate stability. TPV 2.0 TPV 2.5 TPO 2.0 TPO Values in TPV 2.0 Vertical arrangement for SEETIVE 2.0 V collector TPV 2.5 Vertical arrangement for SEETIVE 2.5 V collector TPO 2.0 orizontal arrangement for SEETIVE 2.0 O collector TPO 2.5 orizontal arrangement for SEETIVE 2.5 O collector Fixing systems on flat roofs for VUUM manifolds Fixing kit on flat roof for VUUM series solar collectors. Made of painted steel. omposed of three pieces: bracket horizontal multi-hole, oblique staff manifold holder and vertical multi-position side member to adjust the inclination of the solar field. Possible inclinations: Screws and nuts included TPV VUUM* * For the mounting of a VUUM solar collector 2 fixing kits have to be provided. odice
9 Solar expansion vessel for wall installation Fixed diaphragm expansion tanks in EPDM rubber resistant to peaks of 30 for short periods with disconnection connection and galvanized carbon steel flange. Preload 2.5 Mod. apacity (l) Max pressure () Operating Temp. () Reconciliation Dimensions Ø x () eight (kg) T / x 32 2,9 T / x 4 3,8 T / x 454 5,6 T / x 592 7,8 Solar expansion vessel T Solar expansion vessel T Solar expansion vessel T Solar expansion vessel T Solar expansion vessel for ground installation Expansion membrane with interchangeable membrane in EPDM rubber resistant to peaks of 30 for short periods. Screwed stainless steel flange. Preload 2.5 Mod. apacity (l) Max pressure () Operating Temp. () Reconciliation Dimensions Ø x () eight (kg) T / x 674 2,9 T0 0 - / x 726 7,7 T / +99 /2 554 x Solar expansion vessel T60 Solar expansion vessel T0 Solar expansion vessel T S thermostatic mixing valve for anti-scalding thermal solar systems Thermostatic mixing device manually adjustable with body and fittings made of chrome alloy, complete with shutter in PSU, stainless steel springs and regulation organ that allows to set a variable temperature from 30 to 65 with one accuracy of ± 2 Mod. onnections Static max pressure () Max dynamic pressure () Temp. max () MIX S 5 0 MIX M MIX / Thermostatic mixer MIX S Thermostatic mixer MIX M Thermostatic mixer MIX
10 Fittings kit for SEETIVE manifolds KRS KRS+ fittings kit for a battery of SEETIVE solar collectors complete with terminal joints, safety valve, drain cock, cross connector, probe pocket and manual vent fittings kit for each SEETIVE manifold added with 2 straight 22 double fittings D Quantity Description G G F cockpit ross fitting KRS* D 4 Terminal joint Manual vent E Drain cock KRS+** F G 2 Safety valve Double fitting E G G * Purchase a KRS for each string of collectors ** Purchase a KRS + for each manifold added to the main manifold (for a 4-manifold string choose No. 3 KRS + ) KRS string fittings kit KRS + manifold fittings kit Fittings kit for VUUM manifolds PRO S VUUM fitting and venting kit for air outlet Ø 2 rass fittings for the connections between the delivery and return lines of the systems with i VUUM series solar collectors. The copper output version to tighten includes: - n 2 90 valves with manual threaded brass vent - n 2 reinforcement bushes for pipe diameter 8 - n 2 sealing ogive for pipe diameter 8 - n 2 nuts for 3/4 tightening fitting PRO PRO INV onnection kit and air outlet 3/4 flat stop - n 2 90 valves with manual threaded brass vent, 3/4 flat stop Kit fitting reverse return in copper for the connection of the pipes on the head of thesolar collectors VUUM series. Installable both on the right and on the left of the solar collector according to site specifications. Made of Ø8 copper, it is equipped with two 3/4 connection nipples. Insulation in elastomeric sheath for high temperature, thickness 9. Overall dimensions in width with 20 insulation ircling The VUUM collectors have n. 2 attacks on each side of the header. The installation can be done in an ambidextrous way given the syetry of the circuit, with the possibility of realize the reverse return in an integrated way in the head. There pre-insulated copper curve completes the reverse return. PRO S string fittings kit PRO string fittings kit PRO INV reverse return fittings kit
11 Insulated stainless steel tube for solar thermal systems Roll of pre-insulated stainless steel tube coated with anti-uv film and containing the wire for the solar probe Mod. Diameter (Ø) Reconciliation Insulating TS x 50 TS x 55 TS25 25 /4 x 60 TS6 pre-insulated stainless steel tube m roll TS6 pre-insulated stainless steel tube 5 m roll TS6 pre-insulated stainless steel tube 20 m roll TS6 pre-insulated stainless steel tube 25 m roll 5500 TS20 pre-insulated stainless steel tube m roll TS20 pre-insulated stainless steel tube 5 m roll TS20 pre-insulated stainless steel tube 20 m roll TS20 pre-insulated stainless steel tube 25 m roll TS25 pre-insulated stainless steel tube m roll TS25 pre-insulated stainless steel tube 20 m roll VUUM tube 8 20 P 500 Tube with vacuum cavity external diameter 58 made by coaxially joining two borosilicate glass tubes. Degree of vacuum high and constant over time given the non-permeability of glass to air. Equipped with multilayer metallization based on ions of copper and aluminum placed on the outer surface of the inner tube such as to ensure stability over time of the absorption capacity of the electromagnetic radiation. In the lower part there is a metal spacer with ium ions atmospheric stabilizer getter. Totally recyclable. Glass orosilicate glass Selective layer lnx / u bsorbance > 0,92 Stability. of the vacuum -3/-2 Pa after years Internal pressure -3 Pa Outside diameter 58 ength 0 VUUM tube 8 20 P ,00
Fact Sheet Sky CPC 58
Principle: The CPC 58 solar vacuum tube collector is composed of a series of borosilicate glass pipes with double air gap, welded at the end, inside which a vacuum is closed. The internal air gap is made
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationSolar Collector Product Specifications
Solar Collector Product Specifications AP-10 / AP-22 / AP-30 Overall Dimensions Model AP-10 AP-22 AP-30 Number of tubes 10 22 30 Overall Length (inches) 78 78 78 Overall Width (inches) 31.3 67.5 86.4 Overall
More informationSOLAR THERMAL EQUIPMENT
SOLAR THERMAL EQUIPMENT 6 DIRECT FLOW CPC COLLECTOR Rhico direct flow CPC collectors are acknowledged as the market s premium product. With an extremely low heat loss and optically efficient cylindrical
More informationSOLAR HEATING SYSTEM
SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components
7EN www.caleffi.com Circulation units for solar thermal systems Copyright Caleffi 7HE - 79HE series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Product range Technical specifications Characteristic
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications
28237 www.caleffi.com Circulation units for solar thermal systems Copyright 204 Caleffi 278-279 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Important Product range Technical specifications
More informationavailable in battery up to 4 units for a total of 560 kw
MODULATING CONDENSING BOILER with double premix low NOx burner and double heat exchanger EXPANDABLE IN BATTERY for indoor and outdoor installations (IPX5D) OUTPUT RANGE from 10 to 560 kw (in battery) WORKING
More informationSOLAR ENERGY SYSTEMS. PV Energy Systems & Solar Thermal Systems
PV Energy Systems & Solar Thermal Systems PV ENERGY SYSTEMS Performance Guarantee: 00% 97% 95% 90% Added value from the warranty Linear performance warranty Standard linear warranty 85% 80% 75% 0% 2 3
More informationHCA-58/20(30) SOLAR COLLECTOR INSTALLATION MANUAL
HCA-58/20(30) SOLAR COLLECTOR INSTALLATION MANUAL Copyright:Changzhou He Jia Solar Energy Co.,Ltd www.hjsolar.com.cn - 0 - 1. CAUTIONS 1.1 Gloves and Eye protection must be used when handling glass tubes.
More informationInstallation and Operation Manual for a Solar System with KPW Collectors
Installation and Operation Manual for a Solar System with KPW Collectors EN v. 1.0 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data....... 4 1 Delivery of Mounting
More informationINSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS
INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS 1) INTRODUCTION 2) GENERAL FEATURES 3) OPERATION INSTRUCTIONS 4) SUPPORT BASE AND MOUNTING STEPS 5) FITTINGS & CONNECTIONS
More informationVICTRIX PRO Wall-hung modular condensing boiler for heating only
PRO Wall-hung modular condensing boiler for heating only Wide range (5 models) High efficiency and low pollutant emissions thanks to condensing technology Modulating heat output from 10 to 100% Possible
More informationDS Series Solar System
DS Series Solar System Permit information Consol 30-58-1800 Collector Flat mount on Colorsteel Plumdeck roofing Valve vent, Open loop http:// www.consolsolar.co.nz 21 Page 1 of This system is an evacuated
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationProduct Catalog Evacuated tube collectors CPC OEM CPC w OEM
Product Catalog 2004 Evacuated tube collectors CPC OEM CPC w OEM Table of Contents Development/design Production Outgoing goods warehouse Table of Contents Page Evacuated tube collectors CPC 6 OEM, CPC
More informationInstallation and Operation Manual for a Solar System with KPC1-BP Collectors
Installation and Operation Manual for a Solar System with KPC1-BP Collectors EN v. 1.3 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data....... 4 1 Delivery of Mounting
More informationSINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG
FUNCTION ICMA distribution manifolds are manufactured starting from a special profile of brass bar drawn into CW617-N. They can be divided into: Distribution manifolds with or without connection fittings
More informationPRESSURE CONTROL VALVES SABS 198
PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge
More informationThe appropriate support systems for each SUNSYSTEM product. Robust and safe. Even weight distribution. Diversity of supports
The appropriate support systems for each SUNSYSTE product Support systems specially designed for the SUNSYSTE range of solar appliances. Solar support systems SUNSYSTE cost-effective solution for any roof
More informationModule 7: Cooling System Components
 Â  Basic Cooling System Components Radiators Common Types of Radiators Coolant Hoses Water Pumps Centrifugal Force Types of Drives for Water Pumps Types of Drive Belts Basic Cooling System Components
More information548 hydraulic separator
hydraulic separator 120 C 120 105 C 105 120 Serie 548 120 C 105 C 105 548 imensions C B Function The ltecnic 548 hydraulic separator combines several different components, each of which performs a specific
More informationComponents for central heating
01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0
More informationTechnical Product Submittal
1. General Specifications 1.01 Certifications 1) SRCC OG-100 Technical Product Submittal Oventrop evacuated tube solar thermal collector OVSOL 5-8, 8 tube collector and OVSOL 5-16, 16 tube collector SRCC
More informationK35 HeatBloC with 3-temperature mixing valve
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K35 HeatBloC with 3-temperature
More informationPump Stations for Heating Circuits
Pump Stations for Heating Circuits circulation pumps pump stations manifolds Regulus spol. s r.o., Czech Republic Do Koutů 897/, Praha Tel.: + 7 9, Fax: + 7 97 E-mail: sales@regulus.eu Web: www.regulus.eu
More informationAir Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes
Cooling capacity: Heating capacity: 92,1 to 179,9 kw 69, to 148,7 kw Heating and dehumidification of covered pools Optimized energy consumption Electronic control Description Principle schemes The range
More informationPowertech/Apricus TM AP Solar Collector Specifications
Powertech/Apricus TM AP Solar Collector Specifications Via a Powertech Thermal Store, this new home in Salisbury also uses the 88 tube solar energy array (two on the east side) to heat the pool once the
More informationProduct range Solex Technical data and dimensioning. 5 Years
Qualität made in Germany Product range Solex Technical data and dimensioning Quality made in Germany 5 Years Handwerkergarantie m anufacturer s warranty Product range Solex Dimensioning High-Flow system
More informationMANIFOLDS AND DISTRIBUTION EQUIPMENT
MANIFOLDS AND DISTRIBUTION EQUIPMENT - Radiators distribution equipment... 52 - Components for radiators... 57 - Underfloor heating/cooling distribution equipment... 58 - Modular manifolds... 60 - Components
More informationMaking the World a Better Place
Making the World a Better Place Solar Water Heater Flat Plate Come in different sizes vis. AR-9 (9 fins collectors in Copper/Alluminium) and AR-0 (0 fins collectors in Copper/Alluminium) each to suit different
More informationSolar Thermal. Grant Solar Pump Station Installation & Servicing Instructions
Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant
More informationKS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors
Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break
More informationSPLIT SOLAR HEATER SWSP-200 SWSP-300
READ THIS GUIDE BEFORE STARTING SYSTEM INSTALLATION SPLIT SOLAR HEATER SWSP-200 SWSP-300 INSTALLATION AND OPERATION MANUAL V032018-1 CONTENT 1. Important Information... 3 2. Unpack and Inspect... 5 3.
More informationDISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump
Description This preassembled pump group is part of the arberi trolli HEATING line. This distribution group allows the circulation of the thermal fluid, coming from the primary circuit and it maintains
More informationInstallation manual. Cooling system. Industrial engines DC09, DC13, DC16 OC16. 01:05 Issue 12 en-gb. Scania CV AB 2018, Sweden
Installation manual Cooling system Industrial engines DC0, DC13, DC OC 333 3 01:05 Issue en-gb Changes from the previous issue...3 Design and dimensioning...3 Expansion tank...4 and earlier emission levels...
More informationCALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB
Motorised temperature regulating unit for heating and air conditioning systems 67...WYP - 67...UPM series CCREDITED ISO 9 FM 65 CLEFFI 5/7 G replaces dp 5/ G Function The motorised temperature regulating
More informationM K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency
M K MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency Gas/ gas oil working Output from 44 to 291,7 (from 37.840 to 250.862 of water efficiency). Pipe
More informationFoaming of Lubricating Oils (manual)
Foaming of Lubricating Oils (manual) ASTM D 892, ASTM D 6082 sequence IV, ISO 6247, DIN 51566, IP 146, JIS K2518, BS 5092 (obs.) Product group(s): User group(s): Scope: Lubricant Testing Automotive, Engine
More informationAir Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.
Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water
More informationSolar System with KPG1-ALC Collectors
Installation and Operation Manual Solar System with KPG1-ALC Collectors EN v. 1.2 1 CONTENTS General Installation and Operation Instructions........... 3 1 Supply of Mounting System.................. 4
More informationOPERATION AND INSTALLATION
OPERATION AND INSTALLATION RESIDENTIAL SOLAR PUMP STATION» SE FLOWSTAR PUMP STATION Table of Contents 1 For your safety 1.1 About this manual 1.2 Designated use 1.3 Qualification of the installer 1.4 Hand-over
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationSingle Effect Hot Water Driven Absorption Machine
or uture Energy & Environment Note Single Effect ot Driven bsorption Machine Single Effect Low emperature ot bsorption Chiller erformance Data Chilled Cooling ot Electric Size Weight Model Cooling Capacity.
More informationLHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions
LH High efficiency air to water heat pumps ++ Inverter LH -20 C Inverter +43 C Inverter 20 EVI +60 C Inverter DC INVERTER +58 C EVI +65 C COP 4,1 EVI DC INVERTER EVI DC INVERTER DC COP 4,1 INVERTER COP
More informationCALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB
ACCREDITED Modulating temperature regulating unit with distribution kit for primary circuit 7 series ISO 9 FM 6 / GB replaces /7 GB Function The temperature regulating unit with the distribution kit for
More informationVIESMANN. Installation instructions VITOSOL 200-T. for contractors. Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle
Installation instructions for contractors VIESMANN Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle VITOSOL 200-T 6/2010 Dispose after installation. Safety instructions Please
More information125 EXPANSION VESSEL J N O
125 EXPASI VESSEL pressure tank 126 A Pressure tank Ultra-pro vertical version Max. pressure: 10 bar / 145 psi except for 1100002452: 8 bar/115 psi. 1100001911 19 l 270 411 3/4" - 1" G 1 1100002452 24
More informationCT3202.0_01 EN February 2018
UNDERFLOOR HEATING / RADIATOR HEATING COMPACT BRASS MODULAR MANIFOLDS (centre distance 37 mm) CT3202.0_01 EN February 2018 o o o Super compact: e.g. 11 ways (version code 3211.06.10) in just 60 cm; Insertion
More informationLubrication equipment
Made In Italy Lubrication equipment PRODUCTS CATALOGUE GREASE DISTRIBUTION page 2 OIL DISTRIBUTION page 38 EXHAUSTED OIL ASPIRATORS page 112 TROLLEYS FOR DRUMS TRANSPORT page 118 OIL DRAIN UNITS page 134
More informationReversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)
Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35
More informationINDUSTRIAL DYEING PUMPS
INDUSTRIAL DYEING PUMPS ADVANCED FLUID MANAGEMENT SOLUTIONS Sturdy and reliable industrial and diaphragm pumps. 5 YEARS ANNI DI WARRANTY GARANZIA Made In In Italy HELP THE NATURE Packaging contains, depending
More informationValves for building. Y-strainers... page 204 PVC valves Ball valves... page 204 Butterfly valve... page 204 Ball check valve...
Valves for building Ball valves PN25/20... page 194 PN30/20... page 195 PN40/30 - Lead-free brass... page 196 Valve for gas... page 197 Stem extension valves... page 197 3 way valves... page 197 Mini valves...
More informationsavings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE
TECHNICAL BROCHURE aesthetic performance flexibility thermal comfort PREMIUM QUALITY MECHANICAL STRENGTH IMPROVE CHANGE LIGHTNESS savings high resistance to corrosion low and high temperature systems FULL
More informationSECTION METERS AND GAGES FOR PLUMBING PIPING
PART 1 GENERAL 1.01 SECTION INCLUDES A. Positive displacement meters. B. Flow meters. SECTION 22 0519 METERS AND GAGES FOR C. Pressure gages and pressure gage taps. D. Thermometers and thermometer wells.
More informationSIHI LPH-X - Liquid Ring Vacuum Pump Two Stage
- Liquid Ring Vacuum Pump Two Stage LPH 45008, LPH 45311, LPH 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but
More informationREX/REX F/REX K/REX K F REX DUAL/REX DUAL F
TECHNICAL MANUAL REX/REX F/REX K/REX K F REX DUAL/REX DUAL F PRESSURISED STEEL BOILERS INDEX 1 GENERAL WARNINGS... 4 2 TECHNICAL SPECIFICATIONS... 5 2.1 REX/REX K/REX F/REX K F 7-130 BOILER... 5 2.2 REX/REX
More informationfor Solar Systems with KTU R Collectors
Installation and Operation Manual for Solar Systems with KTU R Collectors EN v. 1.7 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data... 4 1. Mounting System Delivery...
More informationSIHI LPH-X - Liquid Ring Vacuum Pump Two Stage
- Liquid Ring Vacuum Pump Two Stage 45008, 45311, 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction
More informationEvacuated tube collectors
Evacuated tube collectors Evacuated tube collectors The overall performance of ecological heating systems based on solar thermal energy is significantly dependent on how efficiently the solar collector
More informationGASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5
Principle: Because of the warming up the fluid into the absorber pipe converts into steam, the vacuum into the circuit supports this process. The steam rises by its own incentive. The fluid liquefies into
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB
Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally
More informationCatalogue Solar stations DN 20. Solar thermal solutions. Valid for the UK
Catalogue 01 2016 Solar stations DN 20 Solar thermal solutions Valid for the UK Overview product range SolarBloC Solar stations Performance data SolarBloC midi Premium SolarBloC maxi Premium SolarBloC
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model UNO. R EN - Edition 01-15/10/2007
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216080-01EN - Edition 01-15/10/2007 537255 24 MFFI (RO) MET...... 537256 24 MFFI (RO) GPL...... 537632 24 MFFI MET (PL, CZ, UCR)...... 537633 24 MFFI
More informationPRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG
FUNCTION The pre-assembled ICMA collector kits have the function of optimizing the distribution of heat transfer fluid to floor heating systems in order to improve the control of the thermal emission in
More informationBarilla Solar Ltd. Product Brochure. Barilla Solar Lmt Unit 2, Dell Buildings Milford Road Lymington SO41 0ED T:
2014 Barilla Solar Ltd Product Brochure Barilla Solar Lmt Unit 2, Dell Buildings Milford Road Lymington SO41 0ED T: 01590 671 997 www.barillasolar.co.uk Flat Plates & Mounting Systems Barilla F22AR Solar
More information502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:
Model/Ref: 270090022000 www.lauridsenindustri.com CHARACTERISTICS The 502+UM1.5 is a 2-way brass ball valve dedicated to the automatic shut-off of non-corrosive common fluids: water, air, hydrocarbons,
More informationW94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection
Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2
More informationValves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...
Valves for building Ball valves PN25/20... page 262 PN30/20...pages 262 to 263 PN40/30 - Lead-free brass... page 264 Valve for gas... page 265 Stem extension valves... page 265 3 way valves... page 265
More informationZone manifold DN 25, DN 32, DN 50. Mounting and operating instructions
Zone manifold DN 25, DN 32, DN 50 Mounting and operating instructions WOMIX Sportowa 31 89-200 Szubin, Poland phone/fax +48 52 382 44 50, +48 52 382 44 51 www.womix.com.pl e-mail: export@womix.com.pl Central
More informationCALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function
Mixing valves and actuators 610-611 - 612-63 series RIT ISO 01 M 214 LI 01169/17 replaces dp 01169/09 unction The mixing valves allow the centralisation heating system to be regulated by mixing the boiler
More informationSolar System with KPH1 ALP Collectors
Installation and Operation Manual Solar System with KPH1 ALP Collectors EN v. 1.0 1 CONTENTS General Installation and Operation Instructions....... 3 1 Supply of Mounting System............... 4 2 Sloping
More informationWaterPumps QH QV QVK
WaterPumps Q QV QV Introduction IRON Pump /S was founded in 10 and since then the company has manufactured a great variety of pumps covering both the marine and industrial markets. Through the years the
More informationFCU Floor Control Unit
Fully assembled with integrated M3V Control Group including mixing valve and circulating pump and in-line high and low temperature Topway T2 FM manifold options with high and low temperature manifold options
More informationSECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING
SECTION 22 05 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Valves, General 2. Gate Valves 3. Balancing Valves 4. Ball Valves 5. Swing Check Valves 6. Backflow Prevention Assemblies 7. Pressure
More informationCryo Line Systems. Cold memains cold wherever you want!
Cryo Line Systems Cold memains cold wherever you want! www.cryotherm.de Flexible and rigid line systems Cryogenic liquefied gases......like nitrogen, oxygen and argon are stored in special storage vessels
More informationA. This Section includes the following domestic water piping specialties:
SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following domestic water piping specialties: 1. Backflow preventers. 2. Water pressure-reducing
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB
Distribution manifold for radiant panel systems 664 series FM 21654 003 CALEFFI 01260/18 GB replaces 01260/14 GB Function The distribution manifold for radiant panel systems is used to optimally distribute
More informationTECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105
TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to
More informationInstallation and Operation Instructions K38 HeatBloC - DN 32
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K38 HeatBloC - DN 32
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-04EN - Edition 04-01/04/2008 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......
More informationSYSTEM KAN-therm. Underfloor heating. Comfort and efficiency TECHNOLOGY OF SUCCESS ISO 9001
SYSTEM KAN-therm Underfloor heating Comfort and efficiency TECHNOLOGY OF SUCCESS ISO 9001 The underfloor heating of System KAN-therm - pipes and pipe accessories KAN-therm pipe PE-RT with EVOH layer for
More informationGREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER
TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS
More informationFor our present, For their future. Version 11.03
For our present, For their future. SFB-AL (SF-B) series Installation Manual All-glass Evacuated Tubular Solar Collector with Heat Pipe Contents http://www.sunflower-solar.com/ 1. SOLAR COLLECTOR SIZE AND
More informationW91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer
Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY
More informationWirsbo Radiant Heating System
January 1, 2009 PAGE 413-1 Wirsbo Radiant Heating System A1180313 WIRSBO hepex Barrier Tube Cross Linked Polyethylene Heat Transfer tubing with EVOH Oxygen Diffusion Barrier 413-0150 5/16" Nominal hepex:
More informationDOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug
DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant
More informationInstallation and Operation Instructions HeatBloC K31 - DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions HeatBloC K31 - DN 25 2015/03
More informationLinea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN
Linea 28 Mark 1 Serial Number up to 164370001 Outer Casing 1 RIVET 5093 5 LABEL 1781 2 LOCATING CLIP R/H 1881 6 CASE 1922 3 CLIP 5230 7 LOCATING CLIP L/H 1882 4 SELF ADHESIVE ALUM SHEET 5333 1 Main Frame
More informationMAZDON. Table of Contents. Cautions. MAZDON Collector Tube Figure 1 Figure 2
Table of Contents MAZDON Cautions MAZDON Collector Tube Figure 1 Figure 2 Installation Procedure for MAZDON Sloping Roof (M) system Figure 3-6 Figure 7 Installation Procedure for MAZDON Sloping Roof (K)
More informationCALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.
Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium
More information502 VALVE WITH UM ELECTRIC ACTUATOR
502 VALVE WITH UM ELECTRIC ACTUATOR CHARACTERISTICS The 502+UM is a 2-way brass ball valve dedicated to the automatic shut-off of non-corrosive common fluids: water, air, hydrocarbons, etc. It is a full
More information502 VALVE WITH UM ELECTRIC ACTUATOR
502 VALVE WITH UM ELECTRIC ACTUATOR CHARACTERISTICS The 502+UM is a 2 way brass ball valve dedicated to the automatic shut off of non corrosive common fluids: water, air, hydrocarbons, etc. It is a full
More informationLiquid ring vacuum pumps with magnetic coupling
Liquid ring vacuum pumps with magnetic coupling LPH 75320, LPH 75330, LPH 75340 Pressure range: Suction volume flow: 33 to 1013 mbar 485 to 1615 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum
More informationInstallation manual. Excellent efficiency The best characteristics Attractive design. Solartechnik Prüfung Forschung
Installation manual Excellent efficiency The best characteristics Attractive design SOLAR COLLECTORS The Quality Chooses Quality Solartechnik Prüfung Forschung 1 CONTENTS Remarks... 3 Technical specifications...
More informationOPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1
OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2
More informationStainless Steel Water Filled Submersible Motors
Stainless Steel Water Filled Submersible Motors Standard Features 6-7 & 8 Sizes Rewindable Water Cooled - Hz / - V NEMA Mounting Dimensions Stainless Steel Splined Shaft Filter Check Valve Same electrical
More informationBioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced
1 Data Sheet Bioengineering RALF Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. The glass vessels have both a round bottom and stainless steel lid. The system
More information