How to select parts to build an MGO series progressive divider valve assembly, with SAE threading.
|
|
- Poppy McDaniel
- 5 years ago
- Views:
Transcription
1 How to select parts to build an MGO series progressive divider valve assembly, with SAE threading.
2 A simple MGO assembly consists of these basic parts: 1. Inlet 2. Valve sections 3. End section 4. Tie Rods 5. Tie Rod Nuts Other accessories are available as options
3 Which valve sections do you need? MGO Working Sections MGO-150S MGO-300S MGO-450S MGO-600S MGO-150T MGO-300T MGO-450T MGO-600T MGO w/cycle Pin Available RH only MGO-150S MGO-300S MGO-450S MGO-600S MGO-150T MGO-300T MGO-450T MGO-600T
4 Inlet, End, Tie Rods & Nuts One of each required per assembly: MGO Inlet MGO End section FOUR tie rods required per assembly, TWO short (upper) and TWO long (lower). EIGHT nuts required per assembly. (2 for each rod) MGO tie rod nut Select the tie rods according to the number of valve sections in the MGO assembly: Short/Upper Tie Rods (2 required) section tie rod section tie rod section tie rod section tie rod section tie rod section tie rod section tie rod section tie rod section tie rod Long/Lower Tie Rods (2 required) section tie rod section tie rod section tie rod section tie rod 15U857 7-section tie rod section tie rod section tie rod section tie rod section tie rod
5 Optional components Crossports No crossport kits available See appendix C, How to crossport MGO valves For each crossported outlet, order qty 1 of p/n , 7/8-14 SAE pipe plug, to plug the unused outlet. Cycle Indicators p/n , SPDT cycle switch assembly (switch with bracket) Mounted onto the cycle pin to provide electrical signal when valve assembly is cycling Cycle pin can be used without the cycle switch to provide visual indication. For proximity switches, see next page
6 Proximity switches See literature L15600 for more information. Explosion-proof prox switches include 6ft, 3 conductor cable. All others ship without connecting cable, order cable separately (see next page). Part No. Prox. Switch Type Operating Voltage Cable Electric Connection LED Max Cycle Rate Per Min Max Pressure Rating - psi Rated Life - Cycle FSM VDC 4-pin CH Mini No ,000** FSM 115 VAC 5-pin BH Mini No ,000* FSM 115 VAC 3-pin BH Mini No 200 3, ,000, ,000, ,000,000 +
7 Cables for Prox switches Most prox switches ship without a cable, so order the correct cable for the connector on the prox switch: , M12 Cable, Male by Female, 5 m/16 ft (for G3 pump) , 3-Pin Cable, Straight Connector - 6 ft , 3-Pin Cable, Straight Connector - 12 ft , 4-Pin Cable, Straight Connector, Polarity - PNP - 12 ft , 4-Pin Cable, 90 Connector, Polarity - PNP - 12 ft , 5-Pin Cable, Straight Connector - 6 ft , 5-Pin Cable, Straight Connector - 12 ft
8 Performance (High Pressure) Indicators Reset Indicator with Memory Shows you which line is blocked during a lube fault psi
9 Appendix A: MGO Valve Suffixes Code MGO-xxA MGO-xxB MGO-xxC MGO-xxD MGO-xxE MGO-xxF MGO-xxG MGO-xxH MGO-xxI MGO-xxJ MGO-xxK MGO-xxL MGO-xxM MGO-xxN MGO-xxO MGO-xxP MGO-xxQ MGO-xxR MGO-xxS MGO-xxT MGO-xxU MGO-xxV MGO-xxW MGO-xxX MGO-xxY MGO-xxZ Description Twin valve with cycle pin on Right side. Single valve with cycle pin on Right side, outlet on Right side. Single valve with cycle pin on Right side, outlet on Left side. Twin valve with prox switch. Single valve with prox switch, outlet on Right side. Single valve with prox switch, outlet on Left side. Twin valve with cycle pin on Left side. Single valve with cycle pin on Left side, outlet on Right side. Single valve with cycle pin on Left side, outlet on Left side. Standard Single valve, but with outlet on Left side. Twin valve with prox switch, but prox is on the Left side. Single valve with prox switch on Left, outlet on Right side. Single valve with prox switch on Left, outlet on Left side. Standard single valve, with outlet on Right side. Standard twin valve.
10 Appendix B: Technical Specifications Torque Specifications Tie Rod Nut: 12 ft lbs (16 N-m) Outlet Port Plug: 6-8 ft lbs (8-11 N-m) Piston Enclosure Plug: 15 ft lbs (20 N-m) For more specs see L10141 Net Weight lbs (kg) 3 section: 45 (20.46) 4 section: 55 (24.18) 5 section: 62 (27.95) 6 section: 71 (32.17) 7 section: 80 (36.40) 8 section: 90 (40.62) 9 section: 99 (44.84) 10 section: 108 (49.07) 11 section: 118 (53.40)
11 Appendix C: How to crossport MGO valves See next 2 pages
12
13
14 For other options and specialty parts, see the ILE Buyers Guide, or contact Graco. This guide is intended to keep the subject matter as simple as possible, but Graco does offer other optional components.
How to select parts to build an MX series progressive divider valve assembly, with NPT threading.
How to select parts to build an MX series progressive divider valve assembly, with NPT threading. A simple MX assembly consists of these basic parts: 1. Inlet 2. Valve sections 3. End section 4. Tie Rods
More informationMH Modular Divider Valves Product Specs and Ordering. and. Bulletin Revised October 2000
Bulletin 10103 R and MH Modular Divider Valves Product Specs and Ordering Modular, Series- Progressive, Divider Valve Delivers Positive Oil Lubrication for Gas Engines, Compressors and Similar Equipment
More informationMHH Modular Divider Valves
Manzel MHH Modular Divider Valves Available Electronic Only Modular, Series-Progressive, Divider Valve Delivers Positive Oil Lubrication for Gas Engines, Compressors and Similar Equipment at Pressures
More informationYour key to maximum design flexibility with seriesprogressive
Bulletin 10102 R MSP Modular Divider Valves Your key to maximum design flexibility with seriesprogressive reliability. IDEX CORPORATION LUBRIQUIP, INC., A Unit of IDEX Corporation 1995. All Rights Reserved.
More informationSTANDARDIZED MONOBLOC CENTRIFUGAL PUMPS (2-4 POLE) RUGGED AND RESISTANT, WIDE RANGE, HIGH HYDRAULIC PERFORMANCE
NOCCHI NRM RUGGED AND RESISTANT, WIDE RANGE, HIGH HYDRAULIC PERFORMANCE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 The pumps in the NRM series are monobloc single
More informationSeries 3000 Divider Valve Manifold
Series 3000 Divider Valve Manifold Progressive Systems General The Series 3000 progressive divider valve manifold distributes and proportions incoming oil or grease to bearing points. A typical divider
More informationGraco Automatic Lubrication Systems. Durable and Dependable Systems Designed for Industrial Equipment
Graco Automatic Lubrication Systems Durable and Dependable Systems Designed for Industrial Equipment Accurate, Dependable Lubrication Systems When it comes to lubrication, Graco has the answers! While
More informationE FAMILY. Bulletin E 2018
ulletin E 2018 E FMILY Versa Products ompany, Inc., 22 Spring Valley Rd., Paramus, NJ 07652 US Phone: (201)-843-2400 Fax: (201)-843-2931 Versa V, Prins Willem lexanderlaan 1427, 7312 G peldoorn, The Netherlands
More informationFracturing Equipment Lubrication Kits
Fracturing Equipment Lubrication Kits Get the Graco Advantage Because not all oil and gas applications require just one solution, Graco offers multiple levels of advanced control and monitoring and accessories
More informationM2500. Modular Valves for Central Lubrication Systems. Featuring. Valve sections. Zone control valves. Manifold bases. Accessories
M2500 Modular Valves for Central Lubrication Systems Featuring n Valve sections n Manifold bases n Zone control valves n Accessories For oil and grease applications Easy to install. Easy to modify. Easy
More informationControl Valves and Components for Process, Wellhead and Safety Shutdown Systems
Control Valves and Components for Process, Wellhead and Safety Shutdown Systems BULLET B316 2016 ISO 9001 CERTIFIED e-mail: sales@versa-valves.com Versa Products Company, Inc., 22 Spring Valley Road, Paramus,
More informationSERVICE KITS PUMP DATA MODEL PD20X MODEL PE20X INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:
OPERATOR S MANUAL PX20X-XXX-XXX-BXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: 2-2-05 REVISED: 6-30-17 (REV: N) 2" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE
More informationLubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems
LubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems The Choice of Lubrication Professionals. As a hard-working professional focused on ensuring your production lines keep moving
More informationSeries 1000 Divider Valve Manifold
Series 1000 Divider Valve Manifold Progressive Systems General The Series 1000 progressive divider valve manifold distributes and proportions incoming oil or grease to bearing points. A typical divider
More information3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC)
OPERATOR S MANUAL 3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) PX30X-XXX-XXX-CXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: 2-9-05 REVISED: 10-27-17 (REV: N) READ THIS MANUAL CAREFULLY BEFORE
More informationProgram Book/Guidelines for Graco Products
Program Book/Guidelines for Document No.: CL- F- Graco Version G 1.4 Page No.: 2 of 21 Document Management Information The controlled version of this document is the one stored on the GMPT Machinery and
More informationC-316 SERIES. Bulletin C
ulletin -316 2016-316 SERIES Versa Product ompany, Inc., 22 Valley Rd., Paramus, NJ 07652 US Phone: (201)-843-2400 Fax: (201)-843-2931 Versa V, Prins Willem lexanderlaan 1429, 7312 G peldoorn, The Netherlands
More informationComponent List for Graco Trabon Lubrication Systems Products
Component List for Graco Trabon Lubrication Systems Products Document No.: CL- F- Trabon Release Date: December 16, 2016 2017 Graco Inc. 352481 Rev. D 1/1/2017 Page No.: 1 of 54 DOCUMENT MANAGEMENT INFORMATION
More information3000 psi (207 bar) Output/ min. 115 VAC 10cc (0.61 cu. in.) 24 VDC 12cc (0.73 cu. in.) Discharge Element Output Port.
MultiPort Lubricator Grease, Injector General The MultiPort Lubricator is an electrically driven multiple outlet lubrication unit design primarily for use with injector systems. The unit includes two pumping
More informationTable of Contents. Ball bearings
Table of Contents Single Row Deep Groove Ball s Nomenclature... Page B-1 Interchange... Page B-2 Applications... Page B-2 Features... Page B-3 Internal Clearance... Page B-4 Snap Ring and Groove Dimensions...
More informationSERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:
OPERATOR S MANUAL PE20X-X-X-B0S INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 10-17-06 REVISED: 7-15-16 (REV. E) 2" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
More informationCPI offers the DropsA SMX product line as an affordable performance product featuring:
SMX Divider Blocks PRODUCT DESCRIPTION Divider blocks (also known as distribution blocks or divider valves) provided by CPI, precisely distribute correct lubrication, reducing the size of lubricator boxes
More informationTuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual
Tuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual Side Mounted Float Level Switch Read this Manual Before Installing This manual provides information on the Tuffy
More informationC-316 SERIES. Bulletin C
ulletin -316 2018-316 SERIES Versa Product ompany, Inc., 22 Valley Rd., Paramus, NJ 07652 US Phone: (201)843-2400 Fax: (201)843-2931 Versa V, Prins Willem lexanderlaan 1427, 7312 G peldoorn, The Netherlands
More informationNRM CLOSE-COUPLED CENTRIFUGAL PUMPS (2-4 Poles)
NRM OS-OUPD NTRIFUGA PUMPS (2-4 Pole) 79 NRM OS-OUPD NTRIFUGA PUMPS (2-4 Pole) The NRM erie i made up of ingle tage electric monoloc pump with a flanged hydraulic/motor connection. The pump caing i manufactured
More information3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC) PD30X-X-X-C PE30X-X-X-C RELEASED: 2-9-05 REVISED: 3-5-07 (REV. 04) READ THIS MANUAL CAREFULLY BEFORE
More informationDPS280 / DVS280 Series
1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage
More information1-1/2" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
OPERATOR S MANUAL PX15P-XXX-XXX-AXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: 9-5-03 REVISED: 8-31-17 (REV: T) 1-1/2" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY
More informationMultiPort II Lubricator
MultiPort II Lubricator Mobile, Progressive, Grease General The MultiPort II Lubricator is an electrically driven multiple outlet lubrication unit designed primarily for use with progressive divider valve
More informationTank Filling Systems for Petroleum Products
for Petroleum Products Insight Onsite for Petroleum Products Page 2 What is it used for? Generally used with aboveground storage tanks, although some underground uses as well. What is it? An easy means
More informationSERVICE KITS PUMP DATA MODEL PD07P. MODEL PE07P Figure 1 INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:
OPERATOR S MANUAL PX07P-XXX-XXX-AXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: 2-16-07 REVISED: 2-16-18 (REV: M) 3/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY
More informationMultiPort II Lubricator
MultiPort II Lubricator Mobile, PDI, Grease General The MultiPort II Lubricator is an electrically driven multiple outlet lubrication unit designed primarily for use with positive displacement injector(pdi)
More information1-1/2" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
OPERATOR S MANUAL PX15X-XXX-XXX-AXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: 8-7-03 REVISED: 8-31-17 (REV: Y) 1-1/2" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY
More informationPE30R-XXX-XXX-C RELEASED: REVISED: (REV. 07) 3" DIAPHRAGM PUMP
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) PD30R-XXX-XXX-C PE30R-XXX-XXX-C RELEASED: 2-4-05 REVISED: 11-17-10 (REV. 07) READ THIS MANUAL CAREFULLY
More informationSERVICE KITS PUMP DATA SD20S-XXX-XXX-BXXX. SD20R-XXX-XXX-BXXX Figure 1 INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:
OPERATOR S MANUAL SD20X-XXX-XXX-BXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: 7-29-16 REVISED: 11-23-17 (REV: D) 2 FDA SANITARY DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL
More informationProduct Information Page
CONVERTING OLD A-SERIES PART NUMBERS TO THE NEW A-SERIES PART NUMBERS PIP #: SW-PI-77 Applicable to: With the release of the New A-series product family, Ashcroft has A-Series discontinued the old A-series
More informationA system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.
Air/Oil Systems: A lubrication system in which small measured quantities of oil are introduced into an air/oil mixing device which is connected to a lube line that terminates at a bearing, or other lubrication
More informationTechnical Bulletin. Dyna-Power Lubrication D DPD 56. Dual Line Measuring Valves
Dyna-Power Lubrication D-01-03-3 DPD 56 Dual Line Measuring Valves Technical ulletin Dyna-Power Engineers, Inc. 15330 Greenwood Rd. ph:708-333-9300 fax:708-333-7092 e-mail: sales@dyna-power.com November,
More information92 Series MAConnect with Sub D
9 Series MAConnect with Sub D MAXIMUM OF 0 SOLENOIDS CAN BE POWERED BY A SINGLE MULTI-PIN CONNECTOR. UP TO 40 SOLENOIDS CAN BE POWERED BY MEANS OF A SECOND MULTI-PIN CONNECTOR STATION. LEFT OR RIGHT END
More information3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC) PD30R-X-X-C PE30R-X-X-C RELEASED: 2-4-05 REVISED: 3-2-07 (REV. 04) READ THIS MANUAL CAREFULLY BEFORE
More information42 Series MAConnect TM. 42 Series Plug-In Manifold
42 Series MAConnect TM 42 Series Plug-In Manifold Specifications 42 Series Valve Operating Data Fluids: Lubrication: Safe Operating Temperature Range: Pressure Range: Electrical: Air or Inert Gas Not Required.
More informationPE30X-XXX-XXX-C RELEASED: REVISED: (REV. 05) 3" DIAPHRAGM PUMP
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) PD30X-XXX-XXX-C PE30X-XXX-XXX-C RELEASED: 2-9-05 REVISED: 8-4-08 (REV. 05) READ THIS MANUAL CAREFULLY
More informationOperators Manual TTN LUBRICATOR Series Progressive r#9
Operators Manual TTN LUBRICATOR Series Progressive 5580 r#9 Contents Precautions & Symbols... Manufacturer s Statement... General... Application... TTN Lubricator at a Glance... Technical Data...4 ISO
More information1/2" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
OPERATOR S MANUAL PX05P-XXX-XXX-BXXX INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 8-27-08 REVISED: 6-24-16 (REV: H) 1/2" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY
More information3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC)
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) PD30X-XXX-XXX-C PE30X-XXX-XXX-C RELEASED: 2-9-05 REVISED: 7-15-16 (REV: K) READ THIS MANUAL CAREFULLY
More informationOPERATOR S MANUAL PD20P-X-X PE20P-X-X RELEASED: REVISED: (REV: N) 2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) PD20P-X-X PE20P-X-X RELEASED: 12-16-02 REVISED: 10-28-16 (REV: N) READ THIS MANUAL CAREFULLY
More information3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
OPERATOR S MANUAL PE30X-XXX-XXX-C0S INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 12-12-06 REVISED: 5-11-10 (REV. 03) 3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE
More informationRPPN3 - RPPN7 Industrial pressure switch
Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Applications Energy safety equipment Power generation safety equipment Pressurized chambers
More informationAutomated Lubrication System
Automated Lubrication System Installation/Operator Instructions Case IH RBX2 Series Baler Contents Pages Introduction 3 Preparation 4 Bill of Material 5 Component Appendix 6-9 System Operation 10 Valve
More informationLubrication Scientifics, LLC Armstrong Avenue Irvine, CA 92614
The Right Products The Right Values The Right Choice Made in the USA Compressor Lubrication System Products Designed & Manufactured for The Natural Gas Compressor Industry Industries Served: Natural Gas
More information1.1 EP-1 PUMP WITHOUT TIMER
LUBRICATION SYSTMS LCTRIC PUMPS SCTION 1. LCTRIC PUMPS 1.1 P-1 PUMP WITHOUT TIMR APPLICATIONS Hydraulic hammer lubrication or for use in systems with pre-existing or remote timers. SPCIFICATIONS Voltage:
More informationMS Application. Features. Proportional Valve Actuator General Instructions
Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and
More informationPurging Air From Divider Block Lubrication Systems
FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all
More information82 Series MAConnect with Sub-D
82 Series MAConnect with Sub-D Maximum of 20 solenoids can be powered by a single multi-pin connector. Up to 40 solenoids can be powered by means of a second multi-pin connector station. Left or right
More informationAUTHORIZED DISTRIBUTOR DPX PROGRESSIVE DIVIDERS
1 DESCRIPTION Ilcolube is the lubrication system which identifies distribution and dosing with a progressive movement of pistons that are. Controlled one by the other in an interdependent sequence. This
More information+\YH4(*;4 >H[LY 7YLZZ\YL )VVZ[LY :`Z[LT 0UZ[HSSH[PVU 0UZ[Y\J[PVUZ +\YH4(*
WARNING: It is unlawful in CALIFORNIA & VERMONT (effective 1/1/2010); MARYLAND (effective 1/1/2012); LOUISIANA (effective 1/1/2013) and the UNITED STATES OF AMERICA (effective 1/4/2014) to use any product
More informationRepair Parts for Xtreme and XP Xtreme 180cc Lowers
Repair Kit Repair Parts for Xtreme and XP Xtreme 80cc Lowers 4089J EN Important Safety Instructions Read all warnings and instructions in manual 72. Save those instructions. 25D25 Seal Full Repair Kit
More informationRepair Parts for Xtreme and XP Xtreme 220cc Lowers
Repair Kit Repair Parts for Xtreme and XP Xtreme 220cc Lowers 40892J EN Important Safety Instructions Read all warnings and instructions in manual 72. Save those instructions. 25D2 Full Repair Kit - Graco
More informationSERVICE KITS REBUILD KIT DESCRIPTION CHART MODEL DESCRIPTION CHART SPECIFICATIONS X X 1 - B X - X X X - B
OPERATOR S MANUAL INCLUDING: SERVICE KITS, TROUBLESHOOTING, PARTS LIST, DISASSEMBLY & REASSEMBLY. HIGH PRESSURE MATERIAL REGULATOR 65178X-XXX-B RELEASED: 2-12-93 REVISED: 1-11-08 (REV. F) READ THIS MANUAL
More informationLubePro Series Pumps. For Simple, Injector-Based Automatic Lubrication Systems. The Choice of Lubrication Professionals
LubePro Series Pumps For Simple, Injector-Based Automatic Lubrication Systems The Choice of Lubrication Professionals As a hard-working professional focused on ensuring your production lines keep moving
More informationModu-Flo. Trabon. Modu-Flo. Pumps Reservoirs Lube Packages Accessories
Modu-Flo Trabon Modu-Flo Pumps Reservoirs Lube Packages Accessories Modu-Flo concept provides a proven, cost-effective way to assemble customized oil or grease lubrication systems that meet specifi c requirements
More informationLube Level Maintainer
Lube Level Maintainer Models LM500/LM500-TF Installation Instructions 00-02-0729 02-11-11 Section 15 Please read the following information before installing. BEFORE BEGINNING INSTALLATION OF THIS MURPHY
More informationELECTRIC GREASE AND OIL PUMPS ILC-MAX
ELECTRIC GREASE AND OIL PUMPS ILC-MAX ELECTRIC GREASE AND OIL PUMPS - ILC-MAX 24 ELECTRIC GREASE (ILC-MAX-G) OIL (ILC-MAX-O) PUMPS HOW TO ORDER 40.2.24AC.FST.G TANK 2 = 2 Kg transparent 4 = 4 Kg transparent
More informationPeople, Capabilities and Systems to Save Money and Increase Productivity
People, Capabilities and Systems to Save Money and Increase Productivity We re the largest and most successful company in our field because we continually satisfy our customers with the world s best lubrication
More informationLube Level Maintainer
Lube Level Maintainer Models LM500/LM500-TF Installation Instructions 00-02-0729 2015-05-30 Section 15 BEFORE INSTALLING THIS MURPHY PRODUCT: A visual inspection of this product for damage during shipping
More informationP77 Series. Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications. Product Bulletin
P77 Series Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications Product Bulletin Code No. LIT- 24.13 E Issued 10 2009 These pressure controls are designed for use in a
More informationSeries 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.
Model 1A 1C 1G 1Z 1P 1H Inc. Series 1 Series 1 Pressure Switch High, Low, Differential & Vacuum Pressure Switch options available All Anodized Aluminum Construction Multiple s Available UL & cul Approved
More informationBuild A 115 Vac 400 Hz 3 Phase Power Supply Power Avionics And Other 3 Phase Equipment From 12 Volts Dc
Build A 115 Vac 400 Hz 3 Phase Power Supply Power Avionics And Other 3 Phase Equipment From 12 Volts Dc We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our
More informationSERIES HH WITH HYDRAULIC ROD LOCK
HH LOCK TAB HH Rod Lock HH Options SERIES HH WITH HYDRAULIC LOCK The TRD difference... TRD s floating rod bushing design and RL Series Rod Lock = OPTIMIZED RESULTS and SUPERIOR PERFORMANCE. For rod locks
More informationLubemaster Pump DESCRIPTION
Lubemaster Pump DESCRIPTION The Trabon Lubemaster is a rugged, reliable pump for use with Trabon Series Flo divider valves to lubricate all types of machinery. It can be driven by an electric motor or
More informationService and Parts Manual. Minimum Filtration Required:
R GRESEN Hydraulics Model V0 Sectional Body Directional Control Valve Service and Parts Manual Maximum Operating Pressure: Minimum Filtration Required: 00 PSI ( bar) 0 Micron The information in this Service
More informationBarbara, Here is the list of items. I numbered the attachments to match with the numbers below.
From: Dan Wilson [mailto: DWilson@wilsonengineerinciservices.com] Sent: Thursday, April 09, 2015 5:10 PM To: Bernstein, Barbara Subject: RE: checking... Barbara, Here is the list of items. I numbered the
More informationModels CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3
Models 94422 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" MAY - 2004 FORM 403467 Section - Q3 Page - 13C 9.00" (229 mm) 13.75" (350 mm) 0.35" (9mm) Mounting Holes 4.76" (121 mm) 9.84" (250 mm) Do not use
More informationKENCO Oil Level Controllers are designed to maintain the running oil level in the crankcase of stationary engines, compressors and mechanical
KENCO Oil Level Controllers are designed to maintain the running oil level in the crankcase of stationary engines, compressors and mechanical lubricator boxes. The oil controller controls/monitors the
More information2 DIAPHRAGM PUMP 1:1 RATIO(METALLIC)
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION& MAINTENANCE 2 DIAPHRAGM PUMP 1:1 RATIO(METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT. It is the responsibility
More informationCOUNTERS. Concrete Mixer Supply.Com SECTION 6. Counters
Concrete Mixer Supply.Com SECTION 6 Counters 6-1 11 10 1 2 4 12 3 13 14 6-2 7 8 5 9 6 Item # CMS # OEM Part# Description of Part 1 CT 1000 Proximity Switch 2 Wire 1 CT 1000 A 060.110174 Proximity Switch
More informationModel CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"
Model 94222 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" Indicates change MAY - 2004 FORM 403466 Section - Q3 Page - 12B 7.75" (197 mm) 12.6" (321 mm) 0.35" (9 mm) Mounting Holes 4.85" (123 mm) 8.85" (225
More informationData Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable
FEATURES Compact size 36 stainless steel construction Pressure ranges from vacuum to 5,000 psi Factory set or field adjustable setpoints Wide operating temperature range ( 40 C to 00 C) Precision snap-acting
More informationModels CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section
Models 94822 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3 MAY - 2004 FORM 403468 Section Page - 14B 13.00" (330 mm) 17.72" (450 mm).35" (9 mm) Mounting Holes 4.72" (120 mm) 9.84" (250 mm) Figure 1
More informationHard nylon back-up rings for use with U-seals. I.D. C.S. Part. Part Number. Part. Part TEMPERATURE. -65 to +220 f PRESSURE
236 style mbn u-seal back-up rings ard nylon back-up rings for use with U-seals. nylon C.S. W -65 to +220 f 0 to 5,000 psi (Prefix) - (ID) X (CS) X (W) Back-up rings MBN-75X2.5X2.5 MBN-28X3.7X1.5 MBN-40X4X1.4
More informationData Sheet. A-Series Miniature Watertight Pressure Switches
A-Series Miniature Watertight Pressure Switches FEATURES Compact size 36 Stainless steel construction Pressure ranges from vacuum to 000 bar (5.000 psi) Factory set or field adjustable setpoints Wide operating
More informationAccord DS/DM Series UltraSwitch Switch box
Accord DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Accord provides cost efficient, accurate and reliable position signaling
More informationBourdon Tube Pressure Switches
DA /DS Bourdon Tube es Visible setpoint, adjustable deadband, snap action switch pressure ranges to 000 psi Weather-Proof Types DAW, DSW, DRW -/1 2-1/1 REAR MOUNTING FLANGE ().20 DIA. HOLES AT 120 ON -1/2
More informationMultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09
MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed output pumping elements to discharge grease
More informationModular Lube. Automated Lubrication Systems
Modular Lube Automated Lubrication Systems We install Lincoln Industrial Modular Lube systems to protect our equipment and ensure the performance our customers demand. Ryan Riske, Weatherford Compression
More informationWork Light Kit - Installation - Mini Mill - Toolroom Mill
Work Light Kit - Installation - Mini Mill - Toolroom Mill Revision 1 LAST UPDATED: 01/21/2019 AD0100 Machine Compatibility Depending upon the year the machine was built, it will have either a 6.5" (165
More informationProduct Data Sheet. Part Number: Gen 3 Frame LH Fill. Product Technical Specifications
Part Number: 116883 Part Description: Fuel Storage Module (FSM) Gen 3 Frame LH Fill Product Technical Specifications General Specifications Designed Location... Frame Rail Mount (FRM) Gasoline Gallon Equivalancy
More informationSOLUTIONS. Airless Spray System. In This Issue: Airless Spray System pg. 2. Improved FlowMaster pg. 5
THE LATEST PRODUCTS AND NEWS FOR LINCOLN CUSTOMERS SOLUTIONS DECEMBER 2002 VOL. 4, NO. 1 Airless Spray System In This Issue: Airless Spray System pg. 2 Improved FlowMaster pg. 5 MC 2 Progressive High Pressure
More informationTank Filling Systems. for Petroleum Products
Tank Filling Systems for Petroleum Products Tank Filling Systems for Petroleum Products page 2 What Is It Used For? Generally used with aboveground storage tanks, although some underground uses as well.
More informationIL8 Series. Medium Pressure Filters
Medium Pressure Filters Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil patch Flushing
More information1/4" DIAPHRAGM PUMP PUMP DATA. Model PD01X. Model PE01X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
RELEASED 28/Apr/2014 16::18 GMT OPERATOR S MANUAL RELEASED: REVISED: (REV. F) INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE
More informationCLP - Cartridge Lube Pump
General The Cartridge Lube Pump is an electrically driven, single outlet, pump designed for use with the universal grease cartridges widely available in industry today. The lubricator is available with
More informationPart Diagrams. HydraSwing 40/40F Actuator. Part Name Part Number HydraSwing Models (current) Mount, Gate. Valve, Brake. Pin, Cylinder.
HydraSwing 40/40F Actuator Mount, Gate Valve, Brake Pin, Cylinder Hose Kit Brake Manifold Bearing, Tapped Cylinder Kit (Primary or Secondary) Cylinder Kit Cover, Chassis Part Name Part Number HydraSwing
More informationDirect solenoid and solenoid pilot operated valves
Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin Manifold mounting Stacking Manifold base plug-in Manifold base plug-in
More informationSERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:
OPERATOR S MANUAL PD10E-X-X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 6-15-05 REVISED: 7-15-16 (REV. G) 1 DIAPHRAGM PUMP 1:1 RATIO (CONDUCTIVE NON-METALLIC) READ THIS MANUAL CAREFULLY
More informationACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES
ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES 8 VALVE FITTING PART NUMBERS 2" & 3" PRESSURE REDUCING VALVES* 10645 8970-002 (9526-006) 1/4" tube (9526-006) Flow 8970-001 (9526-001) 8970-010 (9526-010)
More informationSERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:
OPERATOR S MANUAL PD20E-X-X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 6-16-05 REVISED: 7-15-16 (REV. H) 2 DIAPHRAGM PUMP 1:1 RATIO (CONDUCTIVE NON-METALLIC) READ THIS MANUAL CAREFULLY
More informationSolenoid Valve Installation Kit
Instruction Sheet P/N 7 5A Solenoid Valve Installation Kit WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related
More informationCP (Vdc) CP (Milliamp) CP (Slidewire)
CP-91-456 (Vdc) CP-91-716 (Milliamp) CP-91-717 (Slidewire) Electronic General Instructions Application Electronic actuator drive is used to provide proportional control of an electric gear train actuator
More informationQLS 321 SOLUTIONS. Compact and Rugged Easy to Install and Use Multiple Standard Features. Quicklub Lubrication Systems.
THE LATEST PRODUCTS AND NEWS FOR LINCOLN CUSTOMERS SOLUTIONS APRIL 2001 VOL. 3, NO. 2 A New Addition To Our Line of Powerful Quicklub Lubrication Systems In This Issue: QLS 321 Compact and Rugged Easy
More information