1 Disconnect Switches Product Guide Rotary Switches Non-fused Fused Enclosed Rotary Operating Mechanisms Accessories

2 December 4 Disconnect Switches 1 Manual Motor Disconnect Switches Contents Description Page Rotary Disconnect Switches C362/C363 Product Description Features, Benefits and Functions Standards and Certifications Options and Accessories Product Selection C362 Non-fused Switches R, W, C, V & S Frames C363 Fusible Switches, C,V, F Frame Switches Handles and Shafts , 6 Accessories Technical Data and Specifications R, W Frame C-Frame V-Frame S-Frame F-Frame Handles Technical Characteristics , 17 Enclosed Rotary Disconnect Switches Product Selection Dimensional Drawings C361/C371 Operating Mechanisms C361 Variable Depth Disconnects C361 Fixed Depth Disconnects C361 Accessories C371 Fixed/Variable Depth Circuit Breakers

3 2 Rotary Disconnect Switches Product Description December 4 Product Description Non-fused R & W frame, A 80A, non-fusible 0V AC, suitable for use in equipment or machinery as a motor disconnect. Manual motor controller suitable for motor disconnect, horsepower and Amp rated, load break rated, meeting requirements of CSA C22.2 No 14 CEC rule 28-2 (3) (b) and UL508 suitable for motor disconnect. 10 kva short circuit rating when used in conjunction with Class fusing. C, V, & S Frame, A - 1A, non-fusible, 0V AC, rated V DC inclusive to 0A. Suitable for use as motor or industrial control panel disconnects, horsepower and Amp rated, load break rated, meeting requirements of CSA C22.2 No 4 and UL98. Fusible A - 800A fusible 0V AC, C, V & F Frame, rated V DC inclusive to A. Suitable for use as motor or industrial control panel disconnect, suitable for use as a service entrance disconnect, horsepower and Amp rated, load break rated, meeting requirements of CSA C22.2 No 4 and UL98. Features, Benefits and Functions Fusible and non-fusible Rotary or toggle operation (non-fused) Motor disconnects available approved to CEC rule 28-2(3)(b) Base mounting or DIN rail mounting Compact design to minimize panel space requirements Pistol type or selector type handles for through-the-door operation. Toggle type handle for internal panel mounting Variable depth complete range of shafts that can be cut for specific enclosure depths Clear ON and OFF indication. Padlockable in the OFF position with up to three padlocks. Interlocked, defeatable handle available. Allows access by authorized personnel in the ON position. ON/OFF/TEST (3 position) handles allow testing of the control circuit auxiliaries without switching the main contacts. Optional N/O, N/C auxiliary contacts available Visible blade indication up to A (non-fused C & V frames) Line side shrouds standard on all ratings for C, S, V & F frames Load side finger shrouds standard on non-fusible -100A C & V frame and -A fusible. Optional shrouds available for higher ratings of V, S & F frame Terminal lugs standard for C & V frame -100A non-fused and -A fusible. Standards and Certifications R- W-Frames UL 508 CSA C22.2 No 14 CEC rule 28-2(3)(b) IEC C-, V-, S-, F-Frames UL 98 CSA C22.2 # 4 IEC CE Options and Accessories Neutral modules. Auxiliary contacts. 4th pole modules. Protective earth modules. C-Frame Non-Fusible C-Frame Fusible V-Frame Fusible V-Frame Non-Fusible R-Frame Non-Fusible W-Frame Non-Fusible S-Frame Non-Fusible F-Frame Fusible NOTE: Photo does not represent proportional sizing between frame types

4 December 4 Rotary Disconnect Switches Product Description 3 Padlocking Handles can be padlocked in the OFF position with up to three padlocks. For safety reasons, the door cannot be opened when the handle is padlocked. 3x 2x 1x 1 maxi. ø 5 16 in / 8 mm 2 Door Interlock in ON Position The handles allow opening of the door in the OFF position only. In the ON position, the door cannot be opened. This interlocking can however be bypassed by authorized personnel (defeater option on handle) for maintenance, testing or commissioning. Figure 1. Padlocking Capability (Type G Pistol Handle is Shown) I-ON OFF Defeater The defeat function allows qualified personnel to bypass the door interlock when the switch is in the ON position by means of a tool. This exclusive design is also available in a 4 and 4X rating. Figure 2. Door Interlocking ON OFF Toggle Option Available for internal panel mounting. Figure 3. Interlocking Defeater Toggle Operated Switch (Shown with Optional Toggle Cover Plate CWP3)

5 4 Rotary Disconnect Switches Product Selection December 4 Product Selection Switches Catalogue Ordering Information When ordering specify: Catalogue number of switch. Catalogue number of operating handle. Pages 5,6. Catalogue number of required shaft. Pages 5,6. Catalogue number of (optional) accessories. Page 7. For dimensional data. Pages 8-. For technical data. Pages 16, 17. Table 1. Non-Fusible Switches Ampere Rating Maximum 3-Phase Horsepower Rating 240V 480V 0V Catalogue DIN Rail / Base Mounted Rotary Switch R-, W-Frame with Brass Collar DIN Rail / Base Mounted Toggle Switch R-, W-Frame DIN Rail / Base Mounted Rotary Switch C-Frame C362NRMD C362NR40MD C362NWMD C362NW80MD C362TRMD C362TR40MD C362TWMD C362TW80MD C362UC Base Mounted Rotary Switch V-Frame Base Mounted Rotary Switch S-Frame C362UV C362UV100 C362UV C362US C362US0 C362US800 C362US1000 C362US1 Note: Suffix MD indicates Manual Motor Controller suitable for Motor Disconnect meeting requirements of CSA C22.2 No.14 CEC rule 28-2(3)(b) and UL508 suitable for motor disconnects. For additional HP ratings refer to pages 16 and 17. Table 2. Fusible Switches Ampere Rating Fuse Type 0V Maximum 3-Phase Horsepower Rating 240V 480V 0V DIN Rail / Base Mounted Fusible Switch C-Frame CC Base Mounted Fusible Switch V-Frame C C Base Mounted Fusible Switch F-Frame L Catalogue C363UCCT (CC) C363UCT () C363UVC C363UV C363UV C363UV100 C363UV C363UV C363UVCT C363UVT C363UVT C363UV100T C363UVT C363UVT C363UF0 C363UF800L Note: T suffix denotes test position is provided. Test handle is required for test function.

6 December 4 Rotary Disconnect Switches Product Selection Handles and Shafts Fusible/Non-Fusible Accessories Product Selection Handles and Shafts Table 5. Handles and Shafts 5 Black Selector Handle Red/ellow Selector Handle Selector Shafts NEMA Rating Defeatable Padlockable Color Operation IEC Type Dimensions Catalogue Inches mm Selector Handle for Type CSSA Shaft and R- and W-Frames or CSCSA Shaft and C-Frames 1 1, 3R, 12 1, 3R, 12 No No No No Black Red/ellow Black ON/OFF IP54 Rotary Switch Selector Shaft 5 x 5 mm (For Selector Handle and R- and W-Frames) Rotary Switch Selector Shaft 5 x 5 mm (For Selector Handle and C-Frames) CSBR5 CSR6 CSBR6 CSSA055 CSSA110 CSSA0 CSSA180 CSSA CSSA0 CSCSA120 CSCSA CSCSA320 CSCSA NEMA Rating Please refer to Page. Defeatable Padlockable Color Operation IEC Type Dimensions Catalogue Inches mm Pistol Handle Type D (For use with CPDSA & CPDCSA Shafts for R- and W-Frames and C-Frame.) 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 12 No No Black Red/ellow Black Red/ellow IP54 IP54 IP54 IP54 Type D Shafts 5 x 5 mm (For use with Type D Pistol Handles and R- and W-Frames) Type D Shafts 5 x 5 mm (For use with Type D Pistol Handles and C-Frames) Direct Handle R-, W-Frames (For Direct Mounting No Separate Shaft Required) 1, 3R, 12 1, 3R, 12 1, 3R, 12 Black Pistol Handle (Type D) Red/ellow Pistol Handle (Type D) Type D Pistol Shafts No No No Black Black Black ON/OFF ON/OFF ON/OFF IP54 IP54 IP CPBR5N CPR5N CPBR5D CPR5D CPDSA120 CPDSA CPDSA320 CPDSA CPDCSA120 CPDCSA CPDCSA320 CPDCSA CDRR3 CDRW3 CDRR4

7 6 Rotary Disconnect Switches Product Selection Handles and Shafts December 4 Table 5. Handles and Shafts (Continued) Black Pistol Handle (Type G) Red/ellow Pistol Handle (Type G) Type G Pistol Shafts NEMA Defeatable Padlockable Color Operation IEC Type Dimensions Catalogue Rating Inches mm Pistol Handle Type G (For use with R-, W- and C-Frames with 5 x 5 shaft and V-Frame below 100A with 10 x 10 shaft) 1, 3R, 12 1, 3R, 12 1, 3R, 12, 4, 4X Black Red/ellow Black IP54 IP54 CPBR5 CPR5 CPBW6 1, 3R, 12, 4, 4X 1, 3R, 12, 4, 4X 1, 3R, 12, 4, 4X Red/ellow- Black Red/ellow TEST/ON/OFF TEST/ON/OFF Long Pistol Handle Type GL (For use with V-Frame 100A and above with 10 x 10 shaft) 1, 3R, 12 1, 3R, 12 1, 3R, 12, 4, 4X 1, 3R, 12, 4, 4X 1, 3R, 12 1, 3R, 12 Black Red/ellow Black Red/ellow Black Red/ellow TEST/ON/OFF TEST/ON/OFF Type G Shafts 5 x 5 mm (For use with Type G Pistol Handle and R- and W-Frames) Type G Shafts 5 x 5 mm (For use with Type G Pistol Handle and C-Frames) Type G Shafts 10 x 10 mm (For use with Type G and GL Pistol Handles and V-Frames) IP54 IP CPW6 CPBW6T CPW6T CPBVR5 CPVR5 CPBVW6 CPVW6 CPBVW6T CPVW6T CPGSA120 CPGSA CPGSA320 CPGSA CPGCSA120 CPGCSA CPGCSA320 CPGCSA CPGSB CPGSB320 CPGSB NEMA Defeatable Padlockable Color Operation IEC Type Dimensions Catalogue Rating Inches mm Pistol Handle Type H (For use with S-Frames with x shaft) 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 No No Black Red/ellow Black Red/ellow CPBSW6D CPSW6D CPBSW6N CPSW6N Pistol Handle Type H (For use with F-Frames with x shaft) 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 No No Black Red/ellow Black Red/ellow Type H Shafts x mm (For use with Type H Pistol Handles and S- and F-Frames) Please refer to Page. Pistol Handle (Type H) CPBFW6D CPFW6D CPBFW6N CPFW6N CPHSC CPHSC

8 December 4 Rotary Disconnect Switches Fusible/Non-Fusible Accessories 7 Product Selection Accessories Table 3. Accessories R, W-Frames Description Catalogue Table 4. Accessories C, S, V, F-Frames Description Catalogue Toggle Cover Plates Auxiliary Contacts Kit (Holder and Contact) Auxiliary Contacts (Additional Contacts) For use with C362TRMD & 40MD For use with C362TWMD & 80MD 1NO for R-Frame ( & 40 Amps) 1NO for W-Frame ( & 80 Amps) 1NO - for R, W-Frame 1NC - for R, W-Frame Extension Support Replacement Brass Collar R and W-Frames Door Mounting Kit R and W-Frames Rotary Switches The mechanism is reversed on these contacts. CRP3 CWP3 CRAC3 CWAC3 CRAB CRAA C362SS1 CRC CTRFC Auxiliary Contact Holders Auxiliary Contacts Load-Side Terminal Shrouds for Non-Fusible V- and S-Frames Load-Side Terminal Shrouds for Fusible V- and F-Frames Shorting Links for 3 Poles Fusible, V- and F-Frames Terminal Lugs for Non-Fusible and Fusible V-, S- and F-Frames, for line or load side C-Frame (for 5-8) V-Frame (for 1-8) S-Frame (for 1-4) 1 NO, Type U aux. contact for C, V, S Frames 1 NC, Type U aux. contact for C, V, S Frames 1 NO/NC, Type S aux. contact, for A-A V-Frames 2 NO/NC, Type S aux. contact, for A-A V-Frames 1 NO/NC, Type ST aux. contact for Fusible, A-A V-Frame w/test 2 NO/NC, Type ST aux. contact for Fusible, A-A V-Frame w/test 1 NO/NC, Type MS aux. contact, for Fusible 0A & 800A F-Frame 2 NO/NC, Type MS aux. contact, for Fusible 0A & 800A F-Frame 3-Pole, V-Frame (A) 3-Pole, for Non-Fusible S-Frame ( - 0A) 3-Pole, for Non-Fusible S-Frame (800-1A) 3-Pole, for Fusible V-Frame (100A) 3-Pole, V-Frame (A) 3-Pole, for Fusible V-Frame (A) 3-Pole, for Fusible F-Frame (0 & 800A) V-Frame (A) V-Frame (100A) V-Frame (A) V-Frame (A) F-Frame (0 & 800A) 1 Wire/lug, Wire Size #12-2/0, for Fusible V-Frame (100A) 1 Wire/lug, Wire Size #6-3/0, for V-Frame (A) 2 Wires/lug, Wire Size #2-0,MCM for V, S- & F-Frames ( & 0A) 3 Wires/lug, Wire Size #2-0, MCM for S-& F-Frames ( A) 2 Wires/lug, Wire Size# 2-0, MCM S-Frame (1A) CUCU CUVU CUSU CUSAA CUSAB CUVAC 0 CUVAD 0 CUVXC 0 CUVXD 0 CUFAC CUFAD CUVT CUS0T CUS1T CUV100T CUVT CUVT CUF800T CUVSL CUV100SL CUVSL CUVSL CUF800SL CUV100LN CUVLN CUS0LN CUS1000LN CUS1LN C-Frames (standard product) hold 1-4 Auxiliary Contacts without additional holder. Line-side terminal shrouds provided as standard on all ratings. Load-side terminal shrouds standard on non-fused C and V-Frames up through 100A. Line-side terminal shrouds provided as standard on all ratings. Load-side terminal shrouds standard on fusible switches up through A. Kit of 3. Terminal lugs provided as standard on Non-Fusible up through 100A and Fusible up through A. Kit of 3. Kit of 6. Aux contacts are Early Break/Late Make. 0 Side mounted aux contact do not have Early Break - they open and close at the same time as the switch.

9 8 Rotary Disconnect Switches Non-fused Technical Data and Specifications M, R, W Frame December 4 Dimensions, Weights and Ratings Dimensions, weights and ratings given in this Product Guide are approximate and should not be used for construction purposes. Drawings containing exact dimensions are available upon request. All listed product specifications and ratings are subject to change without notice. Photographs are representative of production units. Technical Data and Specifications Dimensions in Inches (mm) D 2.17 (55) E A D 2.28 (58) E A 0.34 (8.5) B 1.5 (38) 1.26 (32) L 0.34 (8.5) L B R-Frame W-Frame Figure 4. R- and W-Frames Table 6. R- and W-Frames Dimensions in Inches (mm) Frame Ampere Rating A B D E K L R W (50.8) 2.09 (53.1) 2.75 (69.9) 3.35 (85.1) 2.68 (68.1) 2.88 (73.2) 1.65 (41.9) 1.69 (42.9) 1.89 (48.0) 2.05 (52.1).17 (4.3).17 (4.3) Note: Frame is designated by the sixth character in the switch Catalogue number.

10 December 4 Rotary Disconnect Switches Non-fused Technical Data and Specifications C-Frame 9 Dimensions in Inches (mm) C362UC C A 1 Dual Dimensions Inches (mm) B K K1 X C363UCCT C A 1 K1 X B K H1 C363UCT C A 1 B K K1 X Figure 5. C-Frames Table 7. Dimensions in Inches (mm) Description A B C H H1 H2 H3 1 K K1 3-Pole 3.78 (96.0) 3-Pole 3.78 (96.0) 3-Pole 4.13 (104.9) 4.56 (1.8) 4.56 (1.8) 4.56 (1.8) 2.59 (65.8) 3.28 (83.3) 3.89 (98.8) 1.47 (37.3) 5.19 (131.8) 1.47 (37.3) 1.47 (37.3).59 (.0).59 (.0).59 (.0) 3.13 (79.5) 3.13 (79.5) 3. (83.8) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.12 (28.4) 1.12 (28.4) 1.12 (28.4)

11 10 Rotary Disconnect Switches Non-fused Technical Data and Specifications V-Frame December 4 Dimensions in Inches (mm) C362UV C362UV100 C.4 (10.2) 1.14 (29.0) 1 Dual Dimensions Inches (mm) K1 5 (127.0) X K B A C362UV C 1.14 (29.0) 1.4 (10.2) M 10 H2 K1 5 (127.0) X 6.53 (165.9) K B H3 H2 A Figure 6. Non-Fusible V-Frames Table 8. Dimensions in Inches (mm) Description A B C H H1 H2 H3 1 K K1 3-Pole 6.69 (169.9) 3-Pole 6.69 (169.9) 3-Pole 9.52 (241.8) 5.87 (149.1) 5.87 (149.1) 8.13 (206.5) 3.89 (98.8) 3.89 (98.8) 3.42 (86.9) 1.50 (38.1) 1.50 (38.1) 6.87 (174.5) 4.39 (111.5) 2.44 (62.0) 2.75 (69.9) 2.75 (69.9) 3.68 (93.5) 5.25 (133.4) 5.25 (133.4) 7.50 (190.5) 2.63 (66.8) 2.63 (66.8) 3.74 (95.0).95 (24.1).95 (24.1).95 (24.1)

12 December 4 Rotary Disconnect Switches Fusible Technical Data and Specifications V-Frame 11 Dimensions in Inches (mm) C363UVCT / C363UVC C363UVT / C363UV C363UVT / C363UV C.4 (10.2) 1.14 (29.0) 1 Dual Dimensions Inches (mm) K1 B 5 (127.0) X K A C363UV100T / C363UV100 C363UVT / C363UV C 1.14 (29.0) 1.4 (10.2) M8 M10 H2 K1 5 (127.0) X K3 K B H3 H H (2.1) A Figure 7. Fusible V-Frames Table 9. Dimensions in Inches (mm) Description A B C H H2 H3 1 K K1 K3 3-Pole 5.63 (143.0) 3-Pole 6.72 (170.7) 3-Pole 6.72 (170.7) 3-Pole 8.26 (209.8) 3-Pole 9.44 (239.8) 5.87 (149.1) 5.87 (149.1) 5.87 (149.1) 7.19 (182.6) 8.13 (206.5) 3.89 (98.8) 5.62 (142.7) 5.62 (142.7) 5.63 (143.0) 6.00 (2.4) 1.14 (29.0) 1.50 (38.1) 1.50 (38.1) 4.06 (103.1) 7.27 (184.7) 5.27 (133.9) 6.87 (174.5) 3.66 (93.0) 4.79 (121.7) 2.05 (52.1) 2.44 (62.0) 2.38 (.5) 2.75 (69.9) 2.75 (69.9) 3.28 (83.3) 3.68 (93.5) 5.31 (134.9) 5.31 (134.9) 5.31 (134.9) 6.61 (167.9) 7.56 (192.0) 2.63 (66.8) 2.63 (66.8) 2.63 (66.8) 3.28 (83.3) 3.75 (95.3) 1.21 (.7).95 (24.1).95 (24.1) 5.55 (141.0) 6.53 (165.9) 1.00 (25.4) 1.03 (26.2)

13 12 Rotary Disconnect Switches Fusible Technical Data and Specifications V-Frame December 4 Dimensions in Inches (mm) C363UVT / C363UV Dual Dimensions Inches (mm) C 1.14 (29.0) 1 M 10.4 (10.2) H2 K1 B 5 (127.0) X K H H3 H (165.9) H1 A Figure 8. Fusible V-Frames (Continued) Table 10. Dimensions in Inches (mm) Description A B C H H1 H2 H3 1 K K1 3-Pole (3.0) (363.5) 5.56 (141.2) 5.28 (134.1) (289.8) 7.04 (178.8) 6.59 (167.4) 2.84 (72.1) 2.04 (51.8) 8.83 (224.3) 4.41 (112.0) 1.06 (26.9)

14 December 4 Rotary Disconnect Switches Non-Fusible Technical Data and Specifications S-Frame 13 Dimensions in Inches (mm) C362US C362US0 C Dual Dimensions Inches (mm) 1 ø.51 ø (13.0) H X K1 K2 K B H2 H C362US800 C362US1000 C362US1 H1 C 2.36 (59.9) 2.36 (59.9) 3.42 (86.9) ø 1.3 ø (33.0) 3. (80.0) 1 A H 8.48 (2.4) 8.85 (224.8) H B X K1 K2 K 8.28 (210.3) H (119.9) A Figure 9. Non-Fusible S-Frames Table 11. Dimensions in Inches (mm) Description A B C H H1 H2 1 K K1 K2 3-Pole (279.9) 3-Pole (371.9) 12. (320.0) (3.2) 5.51 (140.0) 5.51 (140.0) 9.05 (229.9) 9.05 (229.9) 5.43 (137.9) 5.43 (137.9) 8.66 (220.0) C362US1 when used with optional terminal lugs CUS1LN. C362US800 and C362US1000 and when used with optional terminal lugs CUS1000LN (280.4) (347.0) 5.00 (127.0) 6.83 (173.5) 6.88 (174.8) 6.88 (174.8) 2.34 (59.4) 2.34 (59.4) 1.10 (27.9) 1.10 (27.9) 1.85 (47.0) 1.85 (47.0)

15 14 Rotary Disconnect Switches Fusible Technical Data and Specifications F-Frame December 4 Dimensions in Inches (mm) C363UF0 C363UF800L 2.36 (59.9) 3.42 (86.9) ø 1. ø (33.0) Dual Dimensions Inches (mm) 2.36 (59.9) C H (105.9) 5.98 (1.9) 1 H2 K1 K 9.17 (232.9) 9.53 (242.1) H B 9.52 (241.8) X (321.8) H (119.9) A Figure 10. Fusible F-Frames Table 12. Dimensions in Inches (mm) Description A B C H H1 H2 H3 1 K K1 3-Pole (436.4) (362.0) (326.9) 9.74 (247.4) (280.9) C363UF800L when used with optional terminal lugs CUS1000LN. C363UF0 when used with optional terminal lugs CUS0LN (220.0) 7.75 (196.9) (345.0) 1.51 (38.4) 9.84 (.0) 4.92 (125.0) 7.48 (190.0)

16 December 4 Rotary Disconnect Switches Technical Data and Specifications Handles Handles Dimensions in Inches (mm) 2.44 (62) 2.44 (62) 0.69 (17.5) 0.49 (12.4) 1.5 (38) 0.31 (8) 5/8" (16) ø 1/16" (1.6) ø 7/8" (23) 2.58 (65.5) 2.48 (63) 1.83 (46.5) ø 1-1/4" (31) DOOR DRILLING I - ON 2 ø 1/8" (3.2) 90º 0 - OFF 2" (50) Figure 11. Selector Handle Figure 14. Pistol Handle Type D 2.87 (73) 2.78 (70.5) 4.98 (126.5) G GL (70) 4 ø 1/8" (3.2) 2" (50) DOOR DRILLING 2" (50) ø 1-1/4" (31) I - ON Test Position 65º 90º 0 - OFF 3. (80) 7.48 (190) 3.94 (100.0) 2" (50) DOOR DRILLING ø 1/8" (3.2) 2" (50) ø 1-1/4" (31) Figure 12. Pistol Handle Type G and Type GL Figure 13. Mounting Depth H Figure. Pistol Handle Type H Table 13. Mounting Depth Dimensions in Inches (mm) Frame Handle Type R W C (CC or Non-fusible) C (-Class Fuse) V (A CC or Non-Fusible V (A A ) V (A A Non-Fusible) V (100A A ) V (A ) S (A 0A) S (800A 1A) Selector Handle 3.00 (76) 3.27 (83) 3.94 (100) Pistol Handle 3.76 (96) 3.94 (100) 4.13 (105) 5.91 (0) Pistol Handle 3.78 (96) 3.94 (100) 4.13 (105) 5.12 (1) 3.94 (100) 6.10 (5) 4.53 (1) 6.50 (165) 6.89 (175) Pistol Handle 8.35 (212) 8.35 (212) F (0A 800A ) (416)

17 16 Rotary Disconnect Switches Technical Characteristics December 4 Table 14. CSA Technical Characteristics Description R-Frame W-Frame Catalogue Catalogue C362NRMD /C362TRMD C362NR40MD /C362TR40MD C362NWMD /C362TWMD C362NW80MD /C362TW80MD Rating Ampere A 40A A 80A CSA C22.2#14/CEC Rule 28-2/ (3)(b) CSA CSA CSA CSA Short Circuit Rating ka with Fuses Fuse Class Fuse Rating (A) Maximum CSA 120V AC Horsepower 208V AC Ratings (3-Phase) V AC V AC V AC Maximum CSA 120V AC Horsepower 208V AC Ratings (1-Phase) 240V AC V AC V AC Electrical Endurance (Operation Cycles) Mechanical Endurance (Operation Cycles) Terminal Lugs Wire Size #14 #4 #14 #4 #14 #1 #14 #1 Wire Type Cu Cu Cu Cu Weight in Lbs. (kg).44 (.20).44 (.20).66 (.).66 (.) Table. CSA/UL Technical Characteristics C, V, S & F Frame Non-Fused and Fusible Catalogue C Frame V Frame V Frame V Frame V Frame S/V Frame S/F Frame S/F Frame S Frame S Frame C362UC C362UCCT C363UCT C363UVC C363UV C363UVCT C363UVT C362UV C363UV C363UVT 2-pole in series. 3-pole in series. x shaft for non-fusible and 10 x 10 shaft for fusible, A DC rating on non-fusible 0A only, no DC rating for 0A fusible. Values on left = non-fusible. Values on right = fusible. C362UV100 C363UV100 C363UV100T C362UV C363UV C363UVT C362US C363UV C363UVT C362US0 C363UF0 C362US800 C363UF800L C362US1000 C362US1 Rating Ampere CSA C22.2 #4/UL98 CSA/UL CSA/UL CSA/UL CSA/UL CSA/UL CSA/UL CSA/UL CSA/UL CSA/UL CSA/UL Short Circuit Rating ka with Fuses 50 CC / ➄ Fuse Class CC / CC / L L L Fuse Rating (A) Maximum UL 240V AC Horsepower (3-Phase) 480V AC V AC DC 125V ➃ DC V ➃ Electrical Endurance Mechanical Endurance Shaft Size Square Switch Operating Torque Terminal Lugs Wire Size Min- Max (Operation Cycles) (Operation Cycles) Inches (mm) /1000➄ ,000 10,000 10,000 10, / 5000 ➄.2 x.2 (5 x 5).4 x.4 (10 x 10).4 x.4 (10 x 10).4 x.4 (10 x 10).4 x.4 (10 x 10).59 x.59 ( x )/.4 x.4 (10 x 10).59 x.59 ( x ) 3500/ 5000➄.59 x.59 ( x ) x.59 ( x ) lb. in / Non- Fused #14 #10 #14 #10 #10 #3 #10 #3 #6-3/0 (2)#2-(2) 0mcm Fusible #14 #10 #14 #10 #10 #3 #14 2/0 #6-3/0 (2)#2-(2) 0 mcm (2)#2-(2) 0mcm (2)#2-(2) 0mcm (3)#2-(3) 0mcm (3)#2-(3) 0mcm (3)#2-(3) 0 mcm.59 x.59 ( x ) (4)#2-(4) 0mcm Weight in Lbs. (kg) 1.1 (.50) 1.1 (.50) 2.0 (.91) 2.5 (1.1) 4.4 (2.0) 8.8 (4.0) 9.9 (4.5) 22.0 (10.0) 28.6 (13.0).8 (14.0)

18 December 4 Rotary Disconnect Switches Technical Characteristics 17 Table 16. IEC Non-Fusible/Fusible Disconnect Switches from 32 to 1 A Description Catalogue C362UC C362UCCT C363UCT C363UVC C363UV C363UVCT C363UVT Value on left = non-fusible/ value on right = fusible. Cable vs busbar connection on 6A. Busbar vs cable connection on 800A. C362UV C363UV C363UVT C362UV100 C363UV100 C363UV100T C362UV C363UV C363UVT C362US C363UV C363UVT C362US0 C363UF0 C362US800 C363UF800L C362US1000 Rating Ampere /6 ➀ Rated Insulation Voltage Ui (V) Rated Impulse Voltage (Uimp) Operation Current (A) V AC AC 22A AC 23A 690 V AC AC 22A AC 23A Motor Power (kw) 8 kv 8 kv 8 kv 8 kv 8 kv 12 kv / 8 kv ➀ / ➀ 12 kv 12 kv 12 kv 12 kv /6 ➀ /6 ➀ /800 ➀ /6 ➀ C362US1 5 x 5 V AC AC 23A V AC AC 23A V AC AC 23A /220 ➀ 185/0 ➀ /0 ➀ Maxi. peak let through /22 ➀ 32 48/36 ➀ 48/77 ➀ 75/77 ➀ current (ka peak) Connection Minimum Cu x 0 2 x x 240 Cable Section (mm 2) Minimum Cu 2 x x 5 ➁ 2 x 40 x 5 2 x 50 x 2 x Busbar Section (mm 2)

19 18 Rotary Disconnect Switches Enclosed Switches December 4 Enclosed Rotary, 40,, 80 Ampere available. 0V, 3 pole, horsepower rated Type 12/3R, 4X Stainless and 4X Non Metallic Enclosures CSA approved to C22.2 #14 CEC rule 28-2(3) (b) manual motor controller suitable for motor disconnect Accepts auxiliary contacts Capability to signal PLC controller 10 kva short circuit rating when used in conjunction with Class fusing Table 17. Rotary Disconnect Switches - Enclosed Switches Ampere Type 12/3R Enclosure Catalogue Non-Fusible 3 Pole, 0V AC CDRUD CDR40UD CDRUD CDR80UD Type 4X Enc losure Stainless Steel Catalogue CDRUW CDR40UW CDRUW CDR80UW Auxiliary Contacts for Enclosed Rotary Switches CRAC3 ➁ CRAC3 ➁ CWAC3 ➁ CWAC3 ➁ Additional Auxiliary Contacts CRAB ➁ CRAA ➁ Type 4X Enc losure Non Metallic Catalogue CDRUX CDR40UX CDRUX CDR80UX Maximum Horsepower Ratings - Volts AC 1 phase AC Maximum Horsepower Ratings - Volts AC 3 phase AC 120V 280V 240 V 480V 0V 120V 280V V Type 12 enclosure can be field modified to meet type 3R rainproof requirements when a factory provided drain hole is opened. The mechanism is reversed on these contacts Auxiliary contact kit contains holder and 1 NO contact Auxiliary contact kit contains holder and 1 NO contact Auxiliary contact kit contains holder and 1 NO contact Auxiliary contact kit contains holder and 1 NO contact 1 NO contact 1 NC contact V V CDR40UX CDRUD CDRUD CDRUW

20 December 4 Rotary Disconnect Switches Enclosed Switches Variable Depth 19 CDR3UD CDR4UD 5.19 [132 MM] I ON 7.12 [181 MM] 6.86 [174 MM] 0 OFF 1.84 [47 MM].31 [8 MM].312 DIA. [8 MM] 6.04 [3 MM] 7.84 [199 MM] 6.00 [2 MM] 1.84 [47 MM] TPE 12/3R ENCLOSURE. SCREW TO BE REMOVED WHEN USED AS TPE 3R DEVICE 4.66 [118 MM] 6.10 [5 MM] NOTE: 1. WIRE RANGE OF SWITCH LUGS IS #4-#14 COPPER. WIRE RANGE OF GROUND LUGS IS #2-#14 COPPER OR ALUMINUM. CDR3

21 20 Rotary Disconnect Switches Enclosed Switches December 4 CDR6UD CDR380UD 7.69 [195 MM] 5.00 [127 MM] 4.99 [127 MM].09 [383 MM] [336 MM] [365 MM] [358 MM] 4.99 [127 MM] 4.82 [122 MM] 6.26 [9 MM] 8.54 [217 MM].312 DIA. [8 MM] TPE 12/3R ENCLOSURE. SCREW TO BE REMOVED WHEN USED AS A TPE 3R DEVICE. NOTE: 1. WIRE RANGE OF SWITCH LUGS IS #4-#14 COPPER. WIRE RANGE OF GROUND LUGS IS #2-#14 COPPER OR ALUMINUM.

22 December 4 Rotary Disconnect Switches Enclosed Switches 21 CDRUW CDR40UW Type 4X Stainless Enclosure 5.19 [132 MM] 7.84 [199 MM] 6.00 [2 MM] 7.12 [181 MM] 6.86 [174 MM] 1.84 [47 MM] 1.84 [47 MM].312 DIA. [8 MM] 6.04 [3 MM] 4.54 [1 MM] 7.26 [184 MM] NOTE: 1. WIRE RANGE OF SWITCH LUGS IS #4-#14 COPPER. WIRE RANGE OF GROUND LUGS IS #2-#14 COPPER OR ALUMINUM.

23 22 Rotary Disconnect Switches Enclosed Switches Flange Mounted Fixed Depth December 4 CDR80UW CDRUW Type 4X Stainless Enclosure 7.69 [195 MM] 5.00 [127 MM].09 [383 MM] [336 MM] [365 MM] [358 MM] OFF [127 MM] ON 4.99 [127 MM] 4.70 [119 MM] 7.42 [188 MM].31 [8 MM] 8.54 [217 MM].312 DIA. [8 MM] NOTE: 1. WIRE RANGE OF SWITCH LUGS IS #1-#14 COPPER. WIRE RANGE OF GROUND LUGS IS #2-#14 COPPER OR ALUMINUM.

24 December 4 Rotary Disconnect Switches Enclosed Switches 23 CDR40UX CDRUX Type 4X Non-Metallic Enclosure.312 [8 MM] DIA. 4 MOUNTING HOLES 7.38 [187 MM] 6.75 [171 MM] OFF ON 1.87 [47 MM] 1.87 [47 MM] 7.47 [190 MM] 2.00 [51 MM] 3.00 [76 MM] 5.44 [138 MM] 4.72 [120 MM] 7.43 [189 MM] 5.50 [140 MM] NOTE: 1. WIRE RANGE OF SWITCH LUGS IS #4-#14 COPPER. WIRE RANGE OF GROUND LUGS IS #2-#14 COPPER OR ALUMINUM. CDRUX CDR80UX Type 4X Non-Metallic Enclosure.312 [8 MM] DIA. 4 MOUNTING HOLES 5.58 [142 MM].75 [ MM].00 [381 MM].88 [403 MM] 5.58 [142 MM] 5.00 [127 MM] 6.00 [2 MM] 6.88 [175 MM] 9.62 [244 MM] 8.75 [222 MM] NOTE: 1. WIRE RANGE OF SWITCH LUGS IS #1-#14 COPPER. WIRE RANGE OF GROUND LUGS IS #2-#14 COPPER OR ALUMINUM.

25 24 Operating Mechanisms with Disconnect Switches Variable Depth December 4 Complete Operating Handle Only Mechanism C361NE1 C361H1 Product Description Type C361 Disconnect Switches are suitable for installation in control enclosures having a right-hand flange. Fusible disconnect switches will accept R fuses as standard. Field installable rejection kits are supplied as standard on 100A and A clips. For A and A rejection clips, see footnote. The switch is CSA/UL component recognized for use on systems with up to,000 rms symmetrical amperes available fault current when Class R clips are supplied. A standard connecting rod is supplied with switch. Options and Accessories Table 1. Electrical Interlocks Circuit 1NO-1NC 2NO-2NC Table 2. Connecting Rods Increase Maximum Allowable Depth by 5 Inches Application Disconnect Switches,, 100 and A Circuit Breakers 0, and A Circuit Breakers 0, 800 and 1A Catalogue DSEK1 DSEK2 Catalogue C371CS1 C371CS2 Table 3. Operating Mechanism Variable Depth with Disconnect Switch Right-Hand Mounting Disconnect Maximum Horsepower Ratings Switch Size (Amperes) Variable Depth Mounting Range Minimum/ Maximum (Inches) AC System Volts (Motor Volts) 208 () 240 (2) 480 (4) 0 (575) DC Using 2 Poles V Maximum Fuse Clip Rating (Amperes) Noninterchangeable Type for Class H,, K or R Type Fuses Only Switch and Operating Mechanism Only DOES NOT Include Handle V 0V Catalogue Switch and Operating Mechanism with 4-Inch Handle For NEMA 1 or 12 Enclosure Catalogue For NEMA 4 Enclosure Catalogue 7 to /2 7-1/ Non-fusible C361NC C361NC1 C361NC2 Dimension shown is from panel to flange surface. Refers to rating of switch only. Components individually boxed and shipped in overpack carton. For rejection clips, add Suffix Letter R to listed Catalogue, and add $9. to price. Example: C361SC121R. Table 4. Handle Only C361SC21 C361SC61 C361SC121 C361SC161 C361SC221 C361SC261 7 to Non-fusible C361ND C361ND1 C361ND2 C361SD22 C361SD62 C361SD122 C361SD162 C361SD222 C361SD to Non-fusible C361NE C361NE1 C361NE C361SE263 C361SE1263 C361SE to Non-fusible C361NF C361NF1 C361NF2 C361SF264 C361SF1264 C361SF2264 Application Operating Handle Length in Inches (mm) NEMA Type Enclosure Catalogue For use with,, 100 and Ampere Disconnect Switches 4.00 (101.6) 4.00 (101.6) 6.00 (2.4) 6.00 (2.4) C361H1 C361H2 C361H3 C361H4

26 December 4 Operating Mechanisms with Disconnect Switches Variable Depth 25 Technical Data and Specifications Datum A D E F C Datum G.62 (.7) 1.62 (41.1) Min. B Figure. Mounting Dimension Requirements Table 18. Mounting Dimension Requirements in Inches (mm) Disconnect Switch Type A B C D E F G A and A Non-fusible A and A Fusible 100A Non-fusible 100A Fusible A Non-fusible and Fusible See Dimensions Below See Dimensions Below 1.56 (39.6) 1.56 (39.6) 1.75 (44.5) 1.75 (44.5) 3.34 (84.8).96 (24.4).96 (24.4) 1.10 (27.9) 1.10 (27.9) 0.63 (16.0) 4.00 (101.6) 4.00 (101.6) 5.50 (139.7) 5.50 (139.7) 8.50 (2.9) 3.50 (88.9) 3.50 (88.9) 3.38 (85.9) 3.38 (85.9) 1.84 (46.7) 7.12 (180.8) 9.75 (247.7) 7.12 (180.8) (1.8).50 (393.7) Table 19. Line Lug Data Disconnect Switch Size Ampere Ampere 100 Ampere Ampere Wire Size #2 14 Cu/Al #2 14 Cu/Al 1/0 14 Cu/Al kcmil #6 Cu/Al Dimension A = The required wire bending spacing selected from Article 4-10 of the National Electrical Code. Dimension B = Minimum or maximum depth from inside of flange holding operating handle to panel where Disconnect Switch is mounted. (Variable 7 to 16 inches.)

27 26 Operating Mechanisms with Disconnect Switches Flange Mounted Fixed Depth December 4 Product Description Type C361 Disconnect Switches are suitable for installation in control enclosures having a right-hand flange. Fusible disconnect switches will accept R fuses as standard. Field installable rejection kits are supplied as standard on 100A and A clips. For A and A rejection clips, see footnote The switch is CSA/UL component recognized for use on systems with up to,000 rms symmetrical amperes available fault current when Class R clips are supplied. Fixed Depth Flange to Panel -A 61/2 inches 100A 7 inches Table 23. Electrical Interlocks Circuit 1NO-1NC 2NO-2NC Table 24. Line Lug Data Disconnect Switch Size Disconnect Switches Ampere Ampere 100 Ampere Ampere Catalogue DSEK1 DSEK2 Wire Size #2 14 AL-CU #2 14 AL-CU #0 14 AL-CU MCM #6 AL-CU Table 25. Operating Mechanism Fixed Depth with Disconnect Switch Right-Hand Mounting Disconnect Switch Size (Amperes) AC System Volts (Motor Volts) Maximum Horsepower Ratings 208 () 240 (2) 480 (4) 0 (575) DC Using 2 Poles V Maximum Fuse Clip Rating (Amperes) Noninterchangeable Type for Class H,, K or R Type Fuses Only Switch and Operating Mechanism with 4-Inch Handle For NEMA 1 or 12 Enclosure V 0V Catalogue 7-1/2 7-1/ Non-fusible C361FNC1 Refers to rating of switch only. For rejection clips, add Suffix Letter R to listed Catalogue. Example: C361FSC121R. C361FSC121 C361FSC Non-fusible C361FND1 C361FSD122 C361FSD Non-fusible C361FNE C361FSE1263 Table 26. Approximate Dimensions Frame Size - Amp. Disc. Switch 0 Amp. Circ. Breaker 100 Amp. Disc. Switch Amp. Circuit Breaker Amp. Circuit Breaker Dimensions in Inches A B C D E 8-5/8 11-3/8 6-1/2 1-1/2 9-1/2 9-7/8 13-3/ /4 11-3/4 D E 3/8 3-3/16 5/16 B 5-13/16 1-3/16 A 3/8" DIA. HOLES FOR PANEL SUPPORT IF NECESSAR DISCONNECT OR CIRCUIT BREAKER C

28 December 4 Operating Mechanisms with Disconnect Switches Accessories 27 Fuse Clips for Variable or Flange Mount Operating Mechanisms C351 Fuse Clip Kit Table 27. C351 Fuse Clip Selection 3 Poles Starter Size Motor Voltage Maximum Horsepower (3-Phase) Dual Element Fuses Fuse Clip Rating Fuse Clip Kit for Field Installation with Non-fusible Starter Amperes Volts Catalogue Catalogue Catalogue Catalogue For Non-rejection Type Fuses For use w/ R Rejection Type Fuses For Form I Type Fuses For Form II Type C Fuses 0 /2 4/575 1 /2 4/ / / / / / Fuse clip R rejection members for use with Class R fuses are supplied loose in the Fuse Clip Kits. Note: Kits do not include fuses C351KC21 C351KD22-61 C351KC21 C351KD22-61 C351KD22-61 C351KD22-61 C351KD62 C351KE23-63 C351KE23-63 C351KE23-63 C351KF24-64 C351KF24-64 C351KF24-64 Not Available in Kit Form C351KC21R C351KD22-61R C351KC21R C351KD22-61R C351KD22-61R C351KD22-61R C351KD62R C351KE23-63 C351KE23-63 C351KE23-63 C351KF24-64 C351KF24-64 C351KF24-64 Not Available in Kit Form C351KD71 C351KD71 C351KD72 C351KE73 C351KF74 Not Available in Kit Form C351KD81 C351KD81 C351KD82 C351KE83 C351KF84 Not Available in Kit Form NEMA 12 Safety Door Hardware Product Selection Type C361 NEMA 12 Safety Door Hardware Type C361 Door Hardware Kits are designed to function with all C361 and C371 disconnect switches and circuit breaker operating mechanisms. These kits are designed for use with small enclosures up to 40 inches (1016 mm), intermediate 40 inches ( mm) or larger floor cases over inches (24 mm) to provide enclosure sealing and protection against unauthorized entry. These kits can be used on enclosure flanges with material thickness ranging from 16 gauge through 3/16 inches with flanges on the right side only. Door hardware kits are to be installed in a commercially available enclosure. Consult the enclosure manufacturer application data for proper kit selection. Table 28. Type C361 NEMA 12 Safety Door Hardware Handle Length (Inches) 4 6 Roller Latch C361KR The 1/4-inch x 1/2-inch standard mill rectangular locking bar is not supplied with these kits. Third roller latch for use with 4 or 6-inch handle when 3 point latching is required. Catalogue C361K4 C361K6

29 28 Circuit Breaker Operating Mechanisms Flange Mounted Fixed Depth December 4 Complete Circuit Breaker Operating Mechanism with Operating Handle C371E1 Handle Only C371H1 Product Description Type C371 Circuit Breaker Operating Mechanisms are designed for installation in control enclosures where main or branch circuit protective devices are required. All circuit breaker mechanisms are suitable for right hand mounting. Auxiliary contacts are not available for mounting on operating mechanism. Where required, have them installed in circuit breaker. Table 29. Operating Mechanisms for Circuit Breakers Flange Mounted Variable Depth Circuit Breaker or Motor Circuit Protector Frame Size Variable Depth Mounting Range Min./Max. (Inches) For increased maximum allowable depth, see Connecting Rods below. Dimensions shown are from panel flange surface. Operating Mechanism Only Does Not Include Handle Catalogue Operating Mechanism With 4 Inch Handle & Rod For NEMA 1-12 Enclosure For NEMA 4 Enclosure Catalogue HMCP, EHD, FDB, FD, FDC, HFD 0 6-1/2 to 16 C371E C371E1 C371E2 HMCP, HD, D, DB, DC HMCP, DK, HKD, KD, KDB 6-1/2 to 16-5/8 C371F C371F5 C371F6 HLD, LD, LDC 0 8-1/2 to 22 C371G C371G5 C371G6 MD, MDS HND, ND, NDC /4 to /4 to 22 C371K C371K5 C371K6 Catalogue Table. Handle Only Circuit Breaker Frame Size (Amperes) NEMA Enclosure Type 0 1-3R R thru 1 1-3R R Operating Handle Length 4 Inches 4 Inches 6 Inches 6 Inches 4 Inches 4 Inches 6 Inches 6 Inches Catalogue C371H1 C371H2 C371H3 C371H4 C371H5 C371H6 C371H7 C371H8 Motor Circuit Protectors Circuit Breakers + + Listed Above Operating Mechanisms Listed Above Operating Handle Channel Support Kit Rod not supplied in Kit For use to prevent bending of the operating handle mounting surface. This is especially useful when the operating handle is mounted on a channel in a multi-door enclosure. Kit included in 0 through 1 ampere mechanisms. Catalogue C371CS6 Table 31. Connecting Rods Increase Maximum Allowable Depth by 5 Inches Application Catalogue Disconnect Switches,, 100, Ampere Circuit Breakers 0,, Ampere Circuit Breakers 0, 800, 1 Ampere C371CS1 C371CS2 For Safety Door Hardware see Page 27

30 December 4 Circuit Breaker Operating Mechanisms Flange Variable Depth, Flange Mounted Fixed Depth 29 Mounting Dimension Requirements Dimension A = 0.75 in. plus the required wire bending spacing selected from Article 4-10 of the National Electrical Code. Dimension B = Minimum or maximum depth from inside of flange holding operating handle to panel where Circuit Breaker is mounted. (variable depth, see page 22) Dimension C = 0 Ampere Size 0.67 in. Ampere Size in. Ampere Size in. 0 Ampere Size 1.71 in Ampere Size 5.17 in.8 Technical Data and Specifications Product Description Type C371 Circuit Breaker Operating Mechanisms are designed for installation in control enclosures with a right hand flange and where main or branch circuit protective devices are required. Auxiliary contacts are not available for mounting on operating mechanism. Where required, have them installed in circuit breaker. Table 32. Flange Mounted Fixed Depth Operating Mechanisms for Circuit Breaker Circuit or Motor Circuit Protector Frame Size Variable Depth Mounting Range Min./Max. (Inches) HMCP, EHD, FDB, FD, FDC, HFD 0 6-1/2 C371FE1 HMCP, HD, D, DB, DC HMCP, DK, HKD, KD, KDB 7 C371FF1 Operating Mechanism With 4 Inch Handle For NEMA 1 or 12 Enclosure Catalogue

31 Notes NOTES December 4

32 December 4 Notes 31

33 32 Notes December 4

34 Eaton Corporation is a diversified industrial manufacturer with 3 sales of $8.1 billion. Eaton is a global leader in fluid power systems and services for industrial, mobile and aircraft equipment; electrical systems and components for power quality,distribution and control; automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety; and intelligent truck drivetrain syst for safety and fuel economy. Eaton has 55,000 employees and sells produc to customers in more than 100 countries. For more information, visit Eaton Corporation 3228 South Service Road Burlington, ON L7N 3H8 Canada Eaton Corporation All Rights Reserved Pub. No.PG.35G.02.T.K December 4 Printed in Canada

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview for Non- Disconnect Switches CDNF16 CDNF100A3 CDNF16A3, CDNF25A3, CDNF32A3 CDNF30A3, CDNF60A3, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF25A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF60A3 CDNF100A3

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information

footprint of traditional fusible switches

footprint of traditional fusible switches Disconnect switches Contents Section page Description Compact Circuit Protector (CCP) disconnect switches Class CC, UL supplemental and IEC 0x38mm (CCP) -3 Class CF CUBEFuse (CCP-CF) 4-5 Compact Circuit

More information

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application Bussmann Open and Enclosed Rotary Disconnect Switches Exceptional Breadth and Availability f Your Application 2 Visit us on the web at www.cooperbussmann.com/disconnects Table of Contents Compact Circuit

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Dry-Type Transformers Mini-Power Centers

Dry-Type Transformers Mini-Power Centers Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum .1 Catalog Number Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

Overview for Fusible Disconnect Switches

Overview for Fusible Disconnect Switches Overview for Fusible Disconnect Switches CFD30CC3 FD800L3 CFD30AJ3 CFD60J3 CFD100J3 FD400J3 FD600J3 FD800L3 number 3 pole CFD30ACC3 CFD30AJ3 CFD60J3 CFD100J3 CFD200J03 FD400J3 FD600J3 FD800L3 General purpose

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...

More information

Disconnect switches Non-fusible Fusible Enclosed

Disconnect switches Non-fusible Fusible Enclosed Disconnect switches Non-fusible Fusible Enclosed Low voltage disconnect switches from ABB ABB is committed to offering high quality and innovative low voltage products. ABB s disconnect switch lines are

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

NON-FUSIBLE DISCONNECT SWITCHES

NON-FUSIBLE DISCONNECT SWITCHES SIRO NON-FUSILE DISONNET SWITHES Ferraz Shawmut SIRO disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-to-date

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview CDNF16 CDNF100A3 CDNF16A3,, CDNF32A3 CDNF30A3,, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF100A3 General purpose amp rating A 16 25 40 60 80 30 60 100 2 pole

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin CWY (painted steel) Or Hoffman Bulletin CWSD (stainless steel) CONCEPT Wall Mounted Disconnect Enclosures

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Disconnect Switches. Bussmann. Bussmann Information Fax ~ Bussmann Worldwide Web ~

Disconnect Switches. Bussmann. Bussmann Information Fax ~ Bussmann Worldwide Web ~ Page Selection Guide Fusible 2 Non-Fusible 3 Handles 4 Disconnect Switches Fusible (30-800A) Features 5-6 Components 7 Accessories 8 Non-Fusible (16-3150A) Features 9 Components 10-14 Accessories 15 Mounting

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊ Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES DESIGN FEATURES Double break contacts Polycarbonate shroud for wired terminal protection included Excellent switching & high short circuit capacity Compact and reliable Easy installation Front, rear and

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K Bolted Contact Pringle Switch Cutler-Hammer Bolted Contact Pringle Switch Effective Date March 16, 2009 Replaces TD.02.56.01.T.K 12 Bolted Contact Switch Offering Features 600 volt CSA 480 volt UL DC ratings

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

MANUALLY OPERATED CHANGEOVER SWITCHES

MANUALLY OPERATED CHANGEOVER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,

More information

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin A19 (painted steel) Or Hoffman Bulletin A19S (stainless steel) Wall Mounted Disconnect Enclosures Rev.

More information

Reduced Voltage Motor Starters

Reduced Voltage Motor Starters Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type

More information

EOEM panelboard and switchboard (OPS) Program

EOEM panelboard and switchboard (OPS) Program Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web:  - disconnect A 1200A, 600VAC Disconnect Disconnect ABB PowerLine includes seven different amperage sizes from A to 1200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting

More information

X1PB: Explosionproof Panelboards

X1PB: Explosionproof Panelboards X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel

More information

Switch Disconnectors

Switch Disconnectors Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information