HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines

Size: px
Start display at page:

Download "HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines"

Transcription

1 HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines PVC jacket - Deg C (optionally PUR material) Glass fibre thermal insulation Process tube(s) Heat reflective tape Electrical heating cable Steam Tracer Electric Traced Bundle Steam Traced Bundle ELECTRIC TRACED TUBING BUNDLE H L / 8 C 7 F S E - C T HOTLINE TM Electric Traced, Tube Bundle * Overjacket (T)hermoplastic or (F)luoropolymer * Tinned Copper Braid Power Supply Voltage, V or V Heating Cable Type Process Tube Wall Thickness.,.,.,.9 Process Tube Material (S)eamless Stainless Steel, (W)elded Stainless Steel, (C)opper Process Tube Size /, /8, / Single () or Dual () Process Tube(s) HOTLINE TM Pre-Insulated Tube Bundle * Not applicable to AHT heating cable STEAM TRACED TUBING BUNDLE L H L / S 9 B HOTLINE TM Steam Traced, Tube Bundle Steam Tracer Type A / x. Copper, B /8 x. Copper Process Tube Wall Thickness.,.,.,.9 Process Tube Material (S)eamless Stainless Steel, (W)elded Stainless Steel, (C)opper Process Tube Size /, /8, / Single () or Dual () Process Tube(s) HOTLINE TM Pre-Insulated Tube Bundle (L)ight or (H)eavy Steam Traced PRE-INSULATED TUBING BUNDLE H L / S 9 HOTLINE TM Pre-Insulated Tube Bundle Process Tube Wall Thickness.,.,.,.9 Process Tube Material (S)eamless Stainless Steel, (W)elded Stainless Steel, (C)opper Process Tube Size /, /8, / Single () or Dual () Process Tube(s) HOTLINE TM Pre-Insulated Tube Bundle

2 Steam Traced Tube Bundles HOTLINE LIGHT STEAM TRACE TUBE BUNDLES The HOTLINE light steam trace tubing consists of a single thermally insulated process line and a single thermally insulated tracer. This is designed for temperature sensitive process lines, sample lines and impulse lines to help prevent freezing and protect fluids against high temperature degradation. Black Thermoplastic Jacket Heat Reflective Tape Non-hygroscopic Glass Fibre Process Tube Non-hygroscopic Glass Fibre 6 Steam Tracer 6 HOTLINE HEAVY STEAM TRACE TUBE BUNDLES The HOTLINE heavy steam trace bundle consists of multiple process lines and a single tracer line designed for the direct heating of process lines and impulse lines. Black Thermoplastic Jacket Heat Reflective Tape Non-hygroscopic Glass Fibre Process Tubes Steam Tracer Typical Connection of Tube Bundle to Enclosure Locknut (part of gland kit) to be positioned inside the enclosure Locknut positioned inside the enclosure Shroud covering gland assembly Gland Assembly Shroud Enclosure HOTLINE TM HOTLINE TM

3 Design Performance DESIGN PERFORMANCE Design Performance The HOTLINE system is designed such that the outer jacket surface temperature will not exceed 6 o C, when the process tube is at o C and the ambient temperature is at 7 o C. Typical Tube Bundle Data Process Tube Steam Tracer Overall Bundle Nom. Bundle Min. Bending O.D. O.D. O.D. (mm) Weight (kg/m) Radius (mm) Single Tube Dual Tube ¼" - ¼"..7 / 8 " - ¼".9 / 8 " - / 8 " 9. ½" - / 8 ".. - ¼" ¼".9 - / 8 " / 8 " 9. - ½" / 8 ".. PERFORMANCE CURVES / (6mm) Process x line / (6mm) Tracer /8 (9mm) Process x Dual lines /8 (9mm) Tracer 8.kg/cm / (mm) Process x line /8 (9mm) Tracer / (mm) Process x Dual lines /8 (9mm) Tracer 8.kg/cm

4 Electric Heat Traced Tube Bundles HOTLINE ELECTRIC TRACING PERFORMANCE FSM The following are typical performance charts. This is because we have various power outputs available and there are a multitude of line sizes and materials. The charts provide a guide only to a systems potential performance.. FSM FREEZSTOP MICRO self-regulating heating cable Power Output (W/m) x 6mm copper tube 7FSM FSM - - Heating cable power output curves are based on V or V power supplies 6 Winterisation and low temperature maintenance FSE. FSE FREEZSTOP EXTRA self-regulating heating cable Power Output (W/m) 9 x 9mm stainless steel tube 7 6 6FSEw FSEw FSE - - Heating cable power output curves are based on V or V power supplies 7FSE Process temperature maintenance to 7 o C 6 8 6

5 Electric Heat Traced Tube Bundles. EMTF MICROTRACER constant power heating cable EMTF SINGLE x 9mm process tube EMTF EMTF 6 EMTF Process temperature maintenance to o C - - AHT. AHT POWERHEAT constant power heating cable DUAL x 9mm process tubes 8 6 AHT 8 6 AHT - AHT - Process temperature maintenance to o C Electric Heater Types Cable FSM FREEZSTOP MICRO FSE FREEZSTOP EXTRA EMTF MICROTRACER AHT POWERHEAT Output Deg C Deg C W/m W/m Deg C Deg C W/m W/m Deg C W/m W/m Deg C Max. Process 6 Deg C 8 Deg C Deg C Deg C Voltage /V /V /V /V Approvals FM Cert. 98 from Dec from Dec 98 ATEX Cert. Sira ATEX7 Sira ATEX76 - Sira ATEX79 SIRA Cert. SCS Ex 99E7 - - SCS Ex 9D Standard EN9 EN9 EN9 EN9 IEEE IEEE IEEE IEEE 7

6 Presented by: Mere's Edge, Chester Road, Helsby, Frodsham, Cheshire, WA6 DJ, UK. Tel: + ()98 76 Fax: + () The information given herein, including drawings, illustrations and schematics (which are intended for illustration purposes only), is believed to be reliable. However, Heat Trace Ltd makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. Users of Heat Trace Ltd products should make their own evaluation to determine the suitability of each such product for specific applications. In no way will Heat Trace Ltd be liable for any damages arising out of the misuse, resale or use of the product. PDG /

FREEZSTOP MICRO SYSTEM

FREEZSTOP MICRO SYSTEM FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 25mm diameter water pipe at +5

More information

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation

More information

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999 STOCKPORT, ENGLAND, TEL: 0161-430 8333 POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS PLEASE READ THE INSTRUCTIONS BEFORE PROCEEDING Recommended Tools ANNEX B Ref TK/AHT Issue C Date 16 August 1999 Heavy

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) 1.0 SCOPE This specification outlines the minimum requirements for electrically traced or steam/fluid traced instrument

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

Heating Cables. For Industry Tracing

Heating Cables. For Industry Tracing Heating Cables For Industry Tracing FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length

More information

120/240 Volts 3 Watt Floor Heating Cable System

120/240 Volts 3 Watt Floor Heating Cable System WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable

More information

Product Overview. Application

Product Overview. Application Self-Regulating SC, SC/H Series-resistance heating cables for longline systems Electrical freeze protection for long pipelines in both nonhazardous and hazardous locations Power-Limiting Mineral Insulated

More information

HTP PTP/ PTJ Power Connection Kit for Pipes

HTP PTP/ PTJ Power Connection Kit for Pipes HTP 1548-40PTP/1548-40PTJ Power Connection Kit for Pipes For use with Dekoron 2700 and 2300 Families of Heating Cables. 1548-81HTJ/81HTP for use with 2000 Series Heating Cables. Installation Instructions

More information

3.0 INSULATED AND HEAT TRACED TUBING BUNDLE

3.0 INSULATED AND HEAT TRACED TUBING BUNDLE 1.0 SCOPE This specification is to be used for: 1.1 Instrument winterizing and protection of field mounted transmitters, manifolds and associated piping when the process fluid is subject to freezing. 1.2

More information

Self-Regulating Parallel Heating Cables. innovations in heat tracing

Self-Regulating Parallel Heating Cables. innovations in heat tracing Self-Regulating Parallel Heating Cables innovations in heat tracing ELSR Application Options The application options for the ELSR heating cables range from freeze protection to maintenance of pipes and

More information

Heating Cable. Cut to Length in Field. Description

Heating Cable. Cut to Length in Field. Description Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection

More information

Kompensator External Low Voltage Heating Cable System

Kompensator External Low Voltage Heating Cable System External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................

More information

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits QTII (X) Series Silicone Rubber Cold Shrink Termination Kits For MV Armored/Non-Armored Cables up to 36kV DATA SHEET Update: August 2006 1. Product Description The 3M QTII (X) Series are Silicone Rubber

More information

Introduction to Heat Trace Cable Systems

Introduction to Heat Trace Cable Systems Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails FIST-GSS2 FIST-GSS3 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Mounting the shelf

More information

TubeTrace Tubing Bundles

TubeTrace Tubing Bundles for Custom CEMS and Analytical Umbilicals English Units Receiving, Storing and Handling... 1. Inspect materials for damage incurred during shipping. Report damages to carrier for settlement. 2. Identify

More information

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

PT8420 Cable Actuated Sensor Industrial ma 0..20mA PT8 Cable ctuated Sensor Industrial.. m..m bsolute Linear Position to 6 inches (5 mm) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous rea Certification

More information

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket SELF-REGULATING HEATING CABLE For pipe freeze protection and flow maintenance Heating cable construction Tinned-copper braid Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket Modified polyolefin

More information

Thermon. SafeTrace TM. BTS Steam Tracer Product Specifications

Thermon. SafeTrace TM. BTS Steam Tracer Product Specifications BTS Steam Tracer Application... SafeTrace BTS is a metallic tracer tube covered with a special high temperature polymer jacket. The SafeTrace BTS jacket provides a measure of personnel burn protection

More information

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system installation guide l 1 Uponor Ecoflex potable PEX plus pre-insulated pipe system

More information

Termination Procedures for Triaxial Connectors D , D , and D

Termination Procedures for Triaxial Connectors D , D , and D Page: 1 of 7 Termination Procedures for Triaxial Connectors D-621-0001, D-621-0002, and D-621-0003 1. Scope This standard covers the procedures for terminating triaxial and twinaxial cables to the triaxial

More information

ProCS and ProC Series Heat Trace Panelboards

ProCS and ProC Series Heat Trace Panelboards ProCS and ProC Series Heat Trace Panelboards Introduction Contents Introduction... 2 System Overview... 3 Certifications... 4 Heat Trace Panel Images... 4-5 AMC Heat Trace Panel (HTP) Selection Guide...

More information

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables... Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss

More information

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage FIST-GMS2 I N S T A L L A T I O N I N S T R U C T I O N FIST Generic Mixed Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1 Mounting

More information

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.

More information

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the

More information

Product Catalogue. Worldwide Specialists in Electric Heat Tracing. HTS THERMTRACE HTS THERMTRACE HTS T

Product Catalogue. Worldwide Specialists in Electric Heat Tracing.  HTS THERMTRACE HTS THERMTRACE HTS T Product Catalogue HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE www.hts-global.com is an international operating manufacturer of electric heating

More information

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails FIST-GSS2 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1

More information

FLEXTRACE. Power (W/m) Dimensions

FLEXTRACE. Power (W/m) Dimensions FST.GB/07/05.07 FLEXTRACE TEMPERATURE MAINTENANCE SYSTEMS www.flexelec.com FST - FST/T - FST/I - FST/TP - FST/TF Self-regulating cables Characteristics Can be cut to length on site. Will not self-destruct

More information

TSRT TSRT Tee Splice Kit Installation Instructions

TSRT TSRT Tee Splice Kit Installation Instructions TSRT TSRT Tee Splice Kit Installation Instructions Description The TSRS Splice Connection Kit is for use with all versions of EasyHeat s self regulating heater cables smaller than 0.44 (11mm) in diameter.

More information

FLEXTRACE. FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration. Applications. Characteristics

FLEXTRACE. FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration.   Applications. Characteristics FSG.GB/07/05.07 FLEXTRACE TEMPERATURE MAINTENANCE SYSTEMS www.flexelec.com FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration Characteristics Can be cut to length on site. Will not

More information

ECONOMY POWER 2.5 CONNECTORS

ECONOMY POWER 2.5 CONNECTORS ECONOMY POWER 2.5 CONNECTORS The Economy Power 2.5 (EP 2.5) connector is a single row or dual row crimp connector system. Based on a 2.5mm (0.098 ) centerline pitch, it is a very compact solution. EP 2.5

More information

ELSR Electric Self-Regulating Parallel Heating Cables

ELSR Electric Self-Regulating Parallel Heating Cables ELSR Electric Self-Regulating Parallel Heating Cables www.hazlocheaters.com www.eltherm.ca 1 Eltherm, a German manufacturer, and Hazloc Heaters (part of The Ouellet Canada Group) have formed a strategic

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, Flamarrest insulation and jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color

More information

Electrical Trace Heating

Electrical Trace Heating Experts for your systems Electrical Trace Heating Quality Reliability Delivery reliability Our knowledge for your application Quintex GmbH i_park Tauberfranken 13 97922 Lauda-Königshofen Germany Tel: +49

More information

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

Products and Accessories. Information Guide

Products and Accessories. Information Guide Products and Accessories Products And Accessories SELF-REGULATING HEATING CABLES Features: Semiconductive Self-Regulating Heating Matrix Cut-to-Length Parallel Circuitry Nickel-Plated Copper Bus Wires

More information

C A Heating Cable Gland Kit Installation Instructions

C A Heating Cable Gland Kit Installation Instructions C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

SUBMERSIBLE TRANSDUCER CABLE REPAIR

SUBMERSIBLE TRANSDUCER CABLE REPAIR SUBMERSIBLE TRANSDUCER CABLE REPAIR One of the most frequent causes of level transducer failure is its cable being cut, which allows moisture to infiltrate the transducer cable jacket. Many of our customers

More information

Available to use in safe and hazardous areas. Eliminates the risk of damage to heating cables at termination points

Available to use in safe and hazardous areas. Eliminates the risk of damage to heating cables at termination points Flexotherm offers DETSU terminations for all heat trace heating cables. It has been specifically designed to reduce the risk of damage to heating cables at termination points, thus avoiding the need to

More information

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction FIST-FPS I N S T A L L A T I O N I N S T R U C T I O N Front Patching Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Side cable termination directly on

More information

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable 3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable Data Sheet September 2010 Description 3M Cold Shrink 3-Conductor

More information

Self-Regulating Cables

Self-Regulating Cables Self-Regulating 1. Self- Regulating 2. Power- Limiting This step-by-step design guide provides the tools necessary to design a self-regulating heat-tracing system for insulated pipes and tubing. For other

More information

SELF-REGULATING CABLES

SELF-REGULATING CABLES Self-Regulating SELF-REGULATING CABLES This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination 3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may

More information

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet

More information

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...

More information

PRODUCTS&ACCESSORIES INFORMATION GUIDE SELF-REGULATING HEATING CABLES HTSXTM BSXTM VSXTM RSXTM KSRTM KSXTM

PRODUCTS&ACCESSORIES INFORMATION GUIDE SELF-REGULATING HEATING CABLES HTSXTM BSXTM VSXTM RSXTM KSRTM KSXTM PRODUCTS&ACCESSORIES INFORMATION GUIDE SELF-REGULATING HEATING CABLES Features: Semiconductive Self-Regulating Heating Matrix Cut-to-Length Parallel Circuitry Nickel-Plated Copper Bus Wires Metallic Braids

More information

QT-III Cold Shrink Silicone Rubber

QT-III Cold Shrink Silicone Rubber QT-III Cold Shrink Silicone Rubber 7600-T-3RJS Series 3/C Cabinet Termination Instructions Kit Contents: 3ÑSilicone Rubber Phase Re-jacketing Sleeve Assembly 3ÑCold Shrink Silicone Rubber Termination Assembly

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

STACKPAK INSTRUCTIONS

STACKPAK INSTRUCTIONS Installation instructions are provided to give the field engineer and installers the necessary information to install STACKPAK in a safe, efficient and effective manner. These recommendations are suggestions

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, PP insulation, PVC jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color coded by

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

Bonstrand PSX L3, PSX L3C, PSX JF and PSX JFC Polysiloxane-phenolic Fire-resistant Fiberglass Pipe and Fittings

Bonstrand PSX L3, PSX L3C, PSX JF and PSX JFC Polysiloxane-phenolic Fire-resistant Fiberglass Pipe and Fittings Bonstrand PSX L3, PSX L3C, PSX JF and PSX JFC Polysiloxane-phenolic Fire-resistant Fiberglass Pipe and Fittings For offshore platforms, marine and onshore service Description Bondstrand PSX JF and PSX

More information

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series 3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

MS4515 SPECIFICATIONS FEATURES APPLICATIONS . SPECIFICATIONS PCB Mounted Pressure Transducers Pressure Ranges from 2 to 30 inches H 2O Amplified Ratiometric Analog Output Differential & Gage Temperature Compensated 3.3V or 5.0 V DC Supply Voltage

More information

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual/Installation Instructions Segurança MSB/HSB Heating System Cold applied connection technology Compulsório Type 27-1.80-...0/...

More information

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual/Installation Instructions Segurança PSB Heating System Heat shrink technology Compulsório Type 27-1680-...0/... OCP 0004

More information

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,

More information

HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS CLOSED- AND OPEN-LOOP CONTROL SYSTEMS HEATERS WATER LEAKAGE DETECTION SYSTEMS

HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS CLOSED- AND OPEN-LOOP CONTROL SYSTEMS HEATERS WATER LEAKAGE DETECTION SYSTEMS HEATING TECHNOLOGY HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS 1 CLOSED- AND OPEN-LOOP CONTROL SYSTEMS 2 HEATERS 3 WATER LEAKAGE DETECTION SYSTEMS 4 PROJECT PLANNING INFORMATION 5 CONTENT

More information

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A

More information

RTB Tubing Bundles Installation Guide. Heating solutions for instrument and small-diameter process lines

RTB Tubing Bundles Installation Guide. Heating solutions for instrument and small-diameter process lines RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines WARNING: Fire and shock hazard. Raychem heat-tracing systems must be installed correctly to ensure

More information

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A 3M Cold Shrink QS-III Inline Splice Kits 15 kv Data Sheet June 2014! CAUTION Working around energized high-voltage systems may cause serious injury or death. Installation should be performed by personnel

More information

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating

More information

LBB ULTRA-PRECISION GAGE HEADS

LBB ULTRA-PRECISION GAGE HEADS s LBB ULTRA-PRECISION GAGE HEADS SPECIFICATIONS Spring and pneumatic extend versions Linear ball bearing front end Extremely long life cycle 0.000004 inch [0.1μm] repeatability ±0.02 to ±0.2 inch [±0.5

More information

Self-regulating cables

Self-regulating cables Self-Regulating Self-regulating cables This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

INSTRUCTIONS. for ZONE HEATERS STACKPAK

INSTRUCTIONS. for ZONE HEATERS STACKPAK Contents Page Model Number and Identification 2-3 Receiving and Storage 4 Installation Minimum Installation Temperature 4 Planning Installation and Determining Length with Zone Heaters 4-5 Uncoiling and

More information

AquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS

AquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS AquiTron Water Shut-Off System INSTALLATION INSTRUCTIONS System Please read these instructions carefully and keep them in a safe place (preferably close to the module) for future reference. These instructions

More information

Connection 1 Connection 2 ft m in mm psi bar in mm

Connection 1 Connection 2 ft m in mm psi bar in mm RUBBER WATERBLAST HOSES These high pressure hose assemblies combine rugged construction, dependability, and safe performance at an economical price.. Constructed with four spiral layers of high tensile

More information

19 1HU Splicing and Front Patching Shelf

19 1HU Splicing and Front Patching Shelf FOMS-FPS-O-XXXX-XX I N S T A L L A T I O N I N S T R U C T I O N 19 1HU Splicing and Front Patching Shelf Contents 1 Introduction 2 General 2.1 Characteristics 2.2 Kit contents 2.3 Tools 3 Installation

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

Electric Heat Tracing INSTALLATION PROCEDURES

Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing Complete Electric Heat Tracing System... Illustration A: Typical Heat Tracing Installation A complete electric heat tracing system will

More information

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930 PRODUCT CODES NAMSR-Wattage-Voltage-Length. Ex: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly

More information

MS4525 SPECIFICATIONS

MS4525 SPECIFICATIONS SPECIFICATIONS PCB Mounted Pressure Transducers Amplified Ratiometric Analog Output Differential, Gage, Absolute, Compound, & Vacuum Temperature Compensated 3.3 or 5.0 Vdc Supply Voltage The MS4525 is

More information

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath Introduction to Heat Trace Cable Systems...6-2 Mineral Insulated Heat Trace Cable...6-2 Non-Metallic Sheath Heat Trace Cable...6-2 Installation Details...6-4 Engineering Guide for Mineral Insulated Cable...6-5

More information

DURAREEL TRAILING REELING CABLE

DURAREEL TRAILING REELING CABLE Supplementary Technical Information Reeling and trailing material characteristics: A. Power core conductor Flexible strands tinned annealed copper complies with AS/NZS 1802, AS/NZS 2802, AS/NZS 1125, and

More information

Flex Tube Elbow w/ Marmon or Flare

Flex Tube Elbow w/ Marmon or Flare Aftertreatment Device V-Band Clamp Flex Tube Elbow w/ Marmon or Flare In-Line Aspirator 2 1. Marmon Adaptor 2. Weld and Clamp Connectors 3. Expanders 4. High Performance Flex 5. Elbows 6. SS Straight Tubing

More information

P U L S A R point 210

P U L S A R point 210 P U L S A R point 210 Page 2 Fourth Edition - Version 1.0 Jan 2014 Copyright Copyright PULSAR Process Measurement Limited 2014. All rights reserved. No part of this publication may be reproduced, transmitted,

More information

FG Series, 230V ac Toroidal Single Primary Transformers

FG Series, 230V ac Toroidal Single Primary Transformers A high quality range of open style toroidal transformers with flying leads. Featuring a single primary winding rated at 230V 50/60Hz, and dual secondary windings. Secondary windings can be connected in

More information

ELE-3COP-359 Title - Braid termination using a Tinel Lock TM ring installed using a resistance heater.

ELE-3COP-359 Title - Braid termination using a Tinel Lock TM ring installed using a resistance heater. Before starting work please read this document carefully and note the guidance given. 1 Purpose and Scope This COP describes the procedure to be used when carrying out the installation of a Tinel-Lock

More information

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications. QS-III 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits Data Sheet Tape Shield Wire Shield UniShield Kit Contents: 1 Cold Shrink Silicone Rubber Splice Body 1 Cold Shrink Adapter Tube

More information

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series 3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series Data Sheet March 2011 Description 3M Cold Shrink 1/C Transition Splice Kits QS-III, 5510A-1T-PILC Series (which includes 5513A-1T-PILC,

More information

Uniflex is the first in India to manufacture hose assemblies using pallet swage fittings.

Uniflex is the first in India to manufacture hose assemblies using pallet swage fittings. Universal Flexibles Pvt. Ltd. is involved in the manufacture of top of the line quality Hydraulic Assemblies having commenced operations at Bangalore in 1987. Tradition of excellence Uniflex is the first

More information

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Explosion-protected surface-mounting Thermostat ATH-Ex Series JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

THERMAL MANAGEMENT

THERMAL MANAGEMENT DESIGN GUIDELINES XL-TRACE LSZH SELF-REGULATING HEATING CABLES FOR PIPE FREEZE PROTECTION SYSTEMS THERMAL MANAGEMENT WWW.PENTAIRTHERMAL.COM PIPE FREEZE PROTECTION SYSTEM OVERVIEW SBS Control Panel T-Connection

More information

PETK Power and End Termination Kit

PETK Power and End Termination Kit Power and End Termination Kit -1 for BSX, RSX, VSX - for KSX, HTSX - for HPT, FP --ECM for HPT, FP --ZT for HPT, FP Order separately to be used in conjunction with Thermon connection kits Receiving, Storing

More information

Power-Limiting Cables

Power-Limiting Cables Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your

More information

Parts List _2.0. Concertor /180

Parts List _2.0. Concertor /180 Parts List 88624_2.0 Concertor 6020.090/80 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3

More information

Self-Regulating Freeze Protection Heating Cable

Self-Regulating Freeze Protection Heating Cable D PDS SRF Self-Regulating Freeze Protection Heating Cable E C B A Output Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Freeze Protection of

More information

Delivering unsurpassed quality, design and value.

Delivering unsurpassed quality, design and value. Delivering unsurpassed quality, design and value. Exergy has been a leading global supplier of heat transfer solutions for over twenty-five years. We utilize state-of-the-art design and manufacturing techniques

More information

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is

More information

I N T R O D U C T I O N

I N T R O D U C T I O N RUBBER CATALOGUE I N T R O D U C T I O N Exitflex (UK) Ltd was established in 1985 as the first major European branch for EXITFLEX SA, the leading Swiss manufacturer of tungsten carbide spray tips, paint

More information