STACKPAK INSTRUCTIONS
|
|
- Allen Horton
- 6 years ago
- Views:
Transcription
1 Installation instructions are provided to give the field engineer and installers the necessary information to install STACKPAK in a safe, efficient and effective manner. These recommendations are suggestions and do not imply that only these methods can be used. CAUTION: ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH ALL APPLICABLE CODES. IF THERE IS A CONFLICT BETWEEN THESE INSTRUCTIONS AND THE REQUIREMENT OF APPLICABLE CODES THE REQUIREMENTS OF THE CODES MUST BE FOLLOWED. TO SATISFY CODE AND APPROVAL AGENCY REQUIREMENTS O'BRIEN POWER CONNECTION AND END TERMINATION KITS MUST BE USED. APPROVALS AND PRODUCT WARRANTY MAY BE VOID IF ALTERNATE CONNECTION KITS ARE USED OR INSTALLATION INSTRUCTIONS AND PROPER END SEALING ARE NOT FOLLOWED. THE ENDS OF THE BUNDLE AND TRACER MUST BE PROTECTED FROM MOISTURE AND WEATHER AT ALL TIMES. THIS INCLUDES TEMPORARILY SEALING AND PROTECTING ALL ENDS DURING INSTALLATION AND HOOKUP. NEVER INSTALL A BUNDLE DURING INCLEMENT WEATHER IF THE ENDS ARE NOT SEALED. NEVER LEAVE A BUNDLE END UNSEALED OVERNIGHT. STACKPAK INSTRUCTIONS Contents Page Model Number and Identification 2-5 Receiving and Storage 6 Installation Minimum Installation Temperature 6 Electrical Insulation Resistance Test 6 Planning and Determining Length 6 Uncoiling and Straightening 6 Additional Instructions for Zone Heaters 7 Minimum Bend Radius 8 Bending 8 Installing Vertical Runs 9 Supporting 10 Sealing the Bundle 11 Power Connection and Termination 11 Temperature Control 12
2 MODEL NUMBER / PRODUCT IDENTIFICATION STACKPAK Model Number Example Model SU-H3S22/S22-TN18/200/K50/5M-XXXXX S STACKPAK U TPU Jacket H3S22 Three heated tubes one H3 3/8" x PFA two S2 1/4" x PFA S22 Two unheated tubes, two S2 1/4" x PFA TN18 240V 18W/ft zone heater for non-hazardous areas overall length K50 Type K thermocouple w/ sensor located 50' from power end 5M 5 Messenger wires Size and configuration is defined during quotation and purchase order. If You Have a 'Z' in the Model Number Some designs may contain tubes, tracers and other components not listed. These components will be designated by a Z in the model number and are defined in the packing list accompanying the shipment. Electric Connections and Terminations Electric tracers must be connected and terminated using approved power connection and termination kits. See instructions provided with the power connection kit. X = Alpha # = Numeric Description X Unit of measure - only used for bundle sold and marked in Meters No prefix designates product is sold and marked in feet M = meters / Separator S STACKPAK Product Designation X Jacket Material S = SV47 O'Brien PVC U = TPU Separator X# Heated tube material, construction and diameter. For tube designations see page 3. Multiple like tubes are designated by multiple number codes: (e.g. H33S2 designates two H3 tubes and one S2 tube. Tube diameter is in 1/8" increments or millimeters if metric. / Separator only if unheated tubes are present. X# tube(s) use the same designation method as heated tubes described above. Separator X# Electric tracer type and wattage output. See pages 4-5. X = unheated Special Options / Separator between each option X Exact and continuous length (Default is in feet. If M/ prefix selected then length is in meters.) X## Temperature Sensor J = Type J thermocouple K = Type K thermocouple T = Type T thermocouple R = 100Ω / 100PT 3 wire RTD XX = distance from power end in chosen units (maximum 50' / 15m) #M Messenger wires (e.g. /3M indicates 3 messenger wires required. Specify type, size and color as notes.) X Jacket Color - default is black A = Gray P = Purple B = Blue R = Red G = Green U = Brown L = Light Blue W = White N = Orange Y = Yellow LC Large Crosshead (internal designation for manufacturing) XXXXX Specials Identifier 2
3 Tube List Designation Material Construction OD Wall Max. Pressure** Max. Continuous Length Possible*** Specifications A2 316/316L SS Welded 1/4" 0.035" 4,080 psig 2,500 ft A269, A1016, EN A3 316/316L SS Welded 3/8" 0.035" 2,640 2,500 A269, A1016, EN A4 316/316L SS Welded 1/2" 0.035" 2,080 2,000 A269, A1016, EN B2 316/316L SS Seamless 1/4" 0.049" 7,500 1,300 A269, A213-EAW, A1016, MR0175, EN B3 316/316L SS Seamless 3/8" 0.049" 4,800 1,000 A269, A213-EAW, A1016, MR0175, EN B4 316/316L SS Seamless 1/2" 0.049" 3, A269, A213-EAW, A1016, MR0175, EN C3 Copper Seamless 3/8" 0.032" 900 2,000 B68, B75, EN D4 Copper Seamless 1/2" 0.035" 800 1,000 B68, B75, EN E4 316/316L SS Welded 1/2" ,975 1,000 A269, A1016, EN F1 316/316L SS Seamless 1/8" 0.035" 10, A269, A213-EAW, A1016, MR0175, EN F2 316/316L SS Seamless 1/4" 0.035" 5,100 2,200 A269, A213-EAW, A1016, MR0175, EN F3 316/316L SS Seamless 3/8" 0.035" 3,300 1,300 A269, A213-EAW, A1016, MR0175, EN F4 316/316L SS Seamless 1/2" 0.035" 2,600 1,000 A269, A213-EAW, A1016, MR0175, EN G2 PFA Extruded 1/4" 0.030" 155 1,000 G2S PFA Extruded 1/4" 0.030" SensorTube Color: BLACK G3 PFA Extruded 3/8" 0.030" 95 1,000 G3S PFA Extruded 3/8" 0.030" SensorTube Color: BLACK G4 PFA Extruded 1/2" 0.030" H2 PFA Extruded 1/4" 0.062" H3 PFA Extruded 3/8" 0.062" H4 PFA Extruded 1/2" 0.062" 155 1,000 J2 Copper Seamless 1/4" 0.030" 1,400 2,600 B68, B75, EN K4 316/316L SS Seamless 1/2" 0.065" 5, A269, A213-EAW, A1016, MR0175, EN M4 Copper Seamless 1/2" 0.049" 1, B68, B75, EN MA12 316/316L SS Welded 12mm 1mm A269, A1016, EN MB10 316/316L SS Seamless 10mm 1.5mm A269, A213-EAW, A1016, MR0175, DIN /1.4404, EN MB12 316/316L SS Seamless 12mm 1.5mm A269, A213-EAW, A1016, MR0175, DIN /1.4404, EN MD6 Copper Seamless 6mm 1mm B68, B75, EN MD8 Copper Seamless 8mm 1mm B68, B75, EN MD12 Copper Seamless 12mm 1mm B68, B75, EN MF6 316/316L SS Seamless 6mm 1mm 460 Bar 300M A269, A213-EAW, A1016, MR0175, DIN /1.4404, EN MF8 316/316L SS Seamless 8mm 1mm A269, A213-EAW, A1016, MR0175, DIN /1.4404, EN MF10 316/316L SS Seamless 10mm 1mm A269, A213-EAW, A1016, MR0175, DIN /1.4404, EN MF12 316/316L SS Seamless 12mm 1mm A269, A213-EAW, A1016, MR0175, DIN /1.4404, EN MG6 PFA Extruded 6mm 1mm MG8 PFA Extruded 8mm 1mm MG10 PFA Extruded 10mm 1mm MG12 PFA Extruded 12mm 1mm N2 Monel Seamless 1/4" 0.035" 4,800 1,000 B163, B165 N3 Monel Seamless 3/8" 0.035" 3, B163, B165 P4 Monel Seamless 1/2" 0.049" 3, B163, B165 S2 PFA Extruded 1/4" 0.040" TrueTube EP: Electropolished, A269, A213-EAW, A1016, MR0175, EN (GREEN identification in bundle) TC1 316/316L SS Seamless 1/8" 0.020" 10, TE2 316/316L SS Seamless 1/4" 0.035" 5, TE3 316/316L SS Seamless 3/8" 0.035" 3, TrueTube FS: Chemically Polished and Passivated with SilcoNert 2000 ID Coating, A269, A213 EAW, A1016, MR0175, EN (LT BLUE identification in bundle) TF1 316/316L SS Seamless 1/8" 0.035" 10, TF2 316/316L SS Seamless 1/4" 0.035" 5,100 2,200 TF3 316/316L SS Seamless 3/8" 0.035" 3,300 1,300 TrueTube EPS: Electropolished with SilcoNert 2000 ID Coating, A269, A213-EAW, A1016, MR0175, EN (RED identification in bundle) TD1 316/316L SS Seamless 1/8" 0.020" 10, TS2 316/316L SS Seamless 1/4" 0.035" 5, TS3 316/316L SS Seamless 3/8" 0.035" 3, *Maximum 72F (23C). Values calculated using S values as specified for metallic tube in ANSI B31.3 code. **Consult Factory for availability of longer continuous lengths. 3
4 Tracer List Select Correct Power Connection and End Termination Kits Depending Upon Electric Tracer Supplied Max. Maintain Max. Intermittent T Connection Kits Tracer Votage W/ft W/m and Exposure Exposure Rating Power Termination Approvals JV F (235C) 500F (260C) T* T250-ET T250-ET JV F (200C) 482F (250C) T* T250-ET T250-ET JV F (170C) 500F (260C) T* T250-ET T250-ET JV F (150C) 482F (250C) T* T250-ET T250-ET JN F (230C) 500F (260C) T* T250-ET T210-PC or T9255- T250-ET PC T355-ET CENELEC EEx es II T* JN F (205C) 482F (250C) T* T250-ET T210-PC or T9255- T250-ET PC T355-ET CENELEC EEx es II T* JN F (170C) 500F (260C) T* T250-ET T210-PC or T9255- T250-ET PC T355-ET CENELEC EEx es II T* JN F (150C) 482F (250C) T* T250-ET T210-PC or T9255- T250-ET PC T355-ET CENELEC EEx es II T* T F (200C) 450F (230C) T* T9G90-UC Non-Hazardous Areas TN F (200C) 450F (230C) T* T9G90-UC Non-Hazardous Areas TY F (200C) 450F (230C) T* T9G90-UC Non-Hazardous Areas Zone Tracers T* Note: T-Rating depends on specific application. See text on bundle for specific T-Rating. Low Temperature Tracers Tracer Votage W/ft W/m Max. Maintain and Exposure Max. Intermittent Exposure T- Rating Power Connection Kits Termination J F (65C) 185F (85C) T6 J F (65C) 185F (85C) T6 J F (65C) 185F (85C) T6 P F (65C) 185F (85C) T6 P F (65C) 185F (85C) T6 P F (65C) 185F (85C) T6 T310-ET10 T310-ET10 T310-ET10 Approvals CSA Cert. Cl I, II Div. 1, 2, Gr. A, B, C, D, E, F, G CSA Cert. Cl I, II Div. 1, 2, Gr. A, B, C, D, E, F, G CSA Cert. Cl I, II Div. 1, 2, Gr. A, B, C, D, E, F, G CSA Cert. Cl I, II Div. 1, 2, Gr. A, B, C, D, E, F, G CENELEC EEx e II T6 CSA Cert. Cl I, II Div. 1, 2, Gr. A, B, C, D, E, F, G CENELEC EEx e II T6 CSA Cert. Cl I, II Div. 1, 2, Gr. A, B, C, D, E, F, G CENELEC EEx e II T6 4
5 High Temperature Tracers with Fluoropolymer Overjacket Tracer Votage W/ft W/m Max. Maintain and Exposure Max. Intermittent Exposure T- Rating Power B F (120C) 420F (215C) T3 B F (120C) 420F (215C) T3 B F (120C) 420F (215C) T2D B F (120C) 420F (215C) T2D N F (120C) 420F (215C) T3 N F (120C) 420F (215C) T3 N F (120C) 420F (215C) T3 N F (120C) 420F (215C) T2C Connection Kits Termination T310-ET13 T310-ET13 T310-ET13 FM T310-ET13 Approvals CENELEC EEx e II T3 CENELEC EEx e II T3 CENELEC EEx e II T3 Appvd. Cl I, II, III Div. 2, Gr. A, B, C, D, F, G CENELEC EEx e II 240 C (T2) 5
6 RECEIVING & STORAGE / INSTALLATION Receiving and Storage Ensure that the protective caps placed over the ends of the bundle are firmly in place to protect from moisture. CAUTION: Fire hazard in hazardous locations. The insulation resisitance test can produce sparks. Be sure there are no flammable vapors in the area before performing this test. Insulation Resistance Criteria A clean, dry, properly installed circuit should measure thousands of megohms, regardless of the heating cable length or measuring voltage. The following criteria are provided to assist in determining the acceptability of an installation where optimum conditions may not apply. All insulation resistance values should be greater than 1 gigaohm (1000 megohms). All bundle ends must be sealed at all times. Protect from mechanical damage. Temperature Range - Storage -60 F to 140 F (-50 C to 60 C) TPU Jacket -30 F to 140 F (-35 C to 60 C) SV47 Jacket Minimum Installation Temperatures Minimum Minimum Identifier Description Installation Service Temperature Temperature S SV47-10 F (-23 C)* -30 F (-35 C) U TPU -40 F (-40 C)* -60 F (-50 C) *Allow tube bundle to rise above the minimum installation temperature if overnight temperatures fall below the minimum installation temperature. Electrical Insulation Resistance (Megger ) Test CAUTION: High voltage testing of electrical insulation poses potential shock hazard and should only be performed by qualified personnel. Frequency Electrical insulation resistance testing is recommended before installing the bundle, prior to initial start-up after bundle installation and as part of regularly scheduled maintenance. Procedure Insulation resistance testing (using a megohmmeter) should be conducted at 500 and 1,000 Vdc. First measure the resistance between the heating cable bus wires and the braid. 1. De-energize the circuit. 2. Disconnect the thermostat or controller if installed. 3. Disconnect bus wires from terminal block if installed. 4. Set test voltage at 0 Vdc. 5. Connect the negative (-) lead to the heating cable metallic braid. 6. Connect the positive (+) lead to both heating cable bus wires simultaneously. 7. Turn on the megohmmeter and set the voltage to 500 Vdc; apply the voltage for 1 minute. The meter needle should stop moving. Rapid deflection indicates a short. Record the insulation resistance value in the Inspection Record. 8. Repeat Steps 4-7 at 1000 Vd. 9. Turn off the megohmmeter. 10. If the megohmmeter does not self-discharge, discharge phase connection to ground with a suitable grounding rod. Disconnect the megohmmeter. 11. Reconnect the thermostat if installed. Planning Installation and Determining Length Route along existing structures such as beams and columns to provide support. Avoid areas where the ambient temperature may exceed 110 F (45 C). Maintain 1 /2" (12mm) minimum air gap between bundles. Measure square into corners. (The length required to make a 90 degree bend is about 13" (330mm). Measuring square into the corner will give you 16" (410mm). The extra 3" (80mm) is part of your safety factor to ensure you have enough length.) Allow 12" - 18" (300mm to 450mm) of straight tubing bundle before connecting to fittings. Allow enough heater cable to reach the junction box and make connections inside considering the minimum length requirements of applicable national and local electrical codes. If the bundle contains a JNx, JVx, T18, TN18 or TY18 heater see special instructions on the following page about locating first and last nodes. If the bundle is supplied with factory finished ends or factory installed temperature sensor, the "Power End", "Probe End" and "Temperature Sensor" location will be marked and must be installed as indicated. Uncoiling and Straightening Method 1 - Roll it out on the floor or other flat surface. This will leave a slight bow that can be taken out by hand. Method 2 - Use a second smaller spool to straighten the product as it is taken off of the larger shipping spool. 6
7 Instructions on this page are for Installation of STACKPAK with zone heaters. JNx, JVx, T18, TN18 and TY18 ONLY - DISREGARD FOR ALL OTHERS. + Buss Wires - Zone heater cables have a series of heater zones. The junction between zones are called NODES. See separate heater cable power and termination kit instructions for information on how to locate node. YOU MUST LOCATE THE FIRST AND LAST NODES TO CORRECTLY INSTALL THIS PRODUCT. Node Zone nodes must also be located when installing splice and tee connections. Do not exceed the maximum circuit length of the heat trace. Refer to the heat trace cut sheet. Only connect bundles of the same model. Insulate the Splice/Tee area to the same physical size. Completely weather seal the area, paying particular attention to the exit points of the tracer. Apply RTV sealant around this area to prevent moisture ingress. See page 9 for sealing product options. Node Zone Length Node When installed, the first node must be a minimum of 6" (150mm) away from the junction box entry gland or the end termination fitting. The heater cable from the cut end to the first node will be unheated. Splice 6" (150mm) Min. Splice Kit 6" (150mm) Min. Node Location Jacket Patch Kit Junction Box Entry Gland Heated Node Location 6" (150mm) Min 6" (150mm) Min End Termination Tee 6" (150mm) Min. Tee Kit 6" (150mm) Min. Allow enough tubing to reach process connections at each end. Bundle length may need to be adjusted to insure that the ends of the tubing are in contact with a heated zone. Tube Tee Jacket Patch Kit WRONG WAY: Process Connection Process Connection Junction Box This Section of Tube Bundle will be UNHEATED! This Section of Tube Bundle will be UNHEATED! End Termination CORRECT WAY: Adjust length of installation so entire bundle length is heated. CAUTION: Do not allow heater cable to overlap itself or come in contact with other heater cable. Position and fasten in place with fiberglass tape supplied in jacket patch kit. Process Connection Process Connection Junction Box 6" (150mm) Min. 6" (150mm) Min. End Termination 7
8 Minimum Bend Radius Minimum bend radius for all products with 5 /8" (16mm) and smaller diameter tubes is 8" (200mm). Minimum bend radius for all products with 3 /4" (19mm) and larger diameter tubes or 2 1 /2" (65mm) and larger bundle diameter is 12" (300mm). To bend on the other (larger) dimension: Method 1 - Make two back to back bends on small dimension and twist the bundle in the direction you want it to go. Bending The jacket will wrinkle when the bundle is bent. This is a normal condition and does not affect the performance or life of the bundle. Applying silicone spray on the bundle jacket will help the bundle slide in the mandrel, especially in cold temperatures. Bend on the small dimension. The bundle will tend to twist and then bend on this dimension naturally. Method 1 - Use O'Brien BB8 or BB12 bundle bending tool. Method 2 - Grasp the bundle firmly and twist it 90. Then make the bend. This technique may also be used to position the tubing for process connection. Method 2 - Use mandrel or spool hub with minimum or larger diameter hub. 8
9 Vertical Runs Two methods are used, one pulls the probe or process end of the bundle into place and the other lifts the product spool to the highest point and lowers the instrument or analyzer end. Lowering Bundle from Top Down If the bundle has factory finished ends or factory installed temperature sensors the probe and power ends will be labeled on the bundle. Pulling Bundle Into Place Temporary Pulling Block Pulling Cable Closed Mesh Support Grips Support Cable O'Brien Split Me O'Brien or Similar Closed Mesh Support Grip Model # Bundle OD OA70095K OA70095K OA70095K OA70095K OA70095K OA70095K OA70095K Split Lace Support Grips Probe End 50' (15m) Maximum Spacing Model # Bundle OD OA70095K OA70095K OA70095K OA70095K OA70095K OA70095K OA70095K O'Brien or Similar Split Mesh Support Grip O'Brien or Similar Split Mesh Support Grip 80' (25m) Maximum Spacing Power End ONLY PULL BUNDLE FROM THE OUTER JACKET When pulling bundle into place the bundle must be attached to pulling cable at intervals not exceeding 50' (15m). Once in place the bundle must be permanently supported following recommended methods at specified support centers. DO NOT ALLOW UNSUPPORTED DROPS GREATER THAN 80' (25m) When lowering bundle into place the bundle must be attached to pulling cable at intervals not exceeding 80' (25m). Once in place the bundle must be permanently supported following recommended methods at specified support centers. Kellems Support Grips may be left in place as secondary support. 9
10 Supporting STACKPAK is not designed for continuous flexing and must be rigidly supported. TRACEPAK Perforated Angle Support Supports and hangers must have a 1 /2" (12mm) minimum surface area with smooth edges and be designed so they can not be overtightened to crush the tubing bundle. Do not use U-bolts as supports. Plastic Tie Wrap or S.S. Banding Angle iron may be used as a support. Place the bundle in an angle sized 1 /2" (12mm) larger than the largest dimension of the bundle and secure it with metal or plastic straps with a 1 /2" (12mm) width minimum. Do not use wire ties or sharp-edge metal banding straps. Cable tray may be used as a support. Maintain a minimum of 1 /2" (12mm) air gap between bundles. 1 /2" (12mm) Stainless Steel Banding with Smooth Edges Existing Insulated Pipe Angle Iron Maximum Support Centers Vertical Runs - 15 feet (5 meters) Horizontal Runs - 6 feet (2 meters) Unsupported Horizontal Runs - 6 feet (2 meters) maximum.* Support centers should be placed so bundle does not sag between supports. This distance will vary by bundle configuration. TRACEPAK Existing Insulated Pipe Plastic Tie Wrap or S.S. Banding TRACEPAK t 1 /2" (12m) Minimum t Standard Cable Tray Fireproof Concrete Column Threaded Rod TRACEPAK Channel Strut Conduit Clamp 13 /16" (20m) UniStrut Spacer Note: Spacer must be secured to bottom row of bundles with Tie Wraps or S.S. Banding Standard Cable Tray 1 /2" (12m) Tie Wrap or S.S. Banding Detail 1 10
11 SEALING THE BUNDLE Sealing the Bundle All bundle ends and connections must be properly sealed to keep the insulation dry. All bundle ends must be temporarily sealed at all times during installation. All bundle ends must be permanently sealed after installation. Refer to the instructions packaged with the end seal selected. Temporary Sealing Methods Any method that is weatherproof and prevents moisture from reaching the insulation is sufficient during installation. Example: Heavy plastic bags may be placed over the bundle ends and temporarily secured with vinyl tape. These methods must be replaced with a suitable permanent weatherproof seal to complete the installation. TPKSK-10 10oz. tube of Black RTV Silicone Sealant maximum service temperature 400 F (204C). TPKSK-10H 10oz. tube of Red RTV Silicone Sealant maximum service temperature 500 F (260 C) continuous 650 F (315C) intermittent. TPKSK-SRT-10 10oz. tube of Black RTV Silicone Sealant and 36 yard roll of Self Fusing Silicone Tape maximum service temperature 400 F (204C). TPKHS Heat Shrink End Boots maximum service temperature 400 F (204C). Use TPKSK-10 if leg does not shrink down to tube OD. Body dia. Min/Max Leg dia. Min/Max Enclosure Entry Seals Maximum service temperature 400 F (204C). IP 65 Model # Max. Panel Maximum Minimum Mounting Hole Thickness (A) Bundle OD (B) Bundle OD (C) Diameter (D) TPKES " (12mm) 1.60" (40mm) 0.75" (19mm) 2" (50mm) TPKES-4S 0.87" (22mm) 2.10" (51mm) 0.75" (19mm) 2-3/8" (60mm) TPKES " (25mm) 2.90" (73mm) 1.43" (36mm) 3-1/2" (90mm) ES6X 1.87" (47mm) 3.60" (89mm) 0.73" (19mm) 4-1/2" (115mm) Max. Panel Thickness (A) Bundle Max. (B) Min. (C) TPKJP-1 Jacket Patch Kit, Small (8 x 8 ) maximum service temperature 400 F (204C). TPKJP-2 Jacket Patch Kit, Large (8 x 96 ) maximum service temperature 400 F (204C). Mounting Hole Diameter (D) Power Connection and Termination Refer to the Tracer List on the following page for the proper power connection and termination kit. Specific installation instructions are provided with each kit. TPKHS-E "/1.30" (9mm/33mm) TPKHS-C2 0.95"/1.90" 0.30"/0.75" TPKHS-D2 (24mm/48mm) (8mm/19mm) 0.45"/1.60" 0.15"/0.55" TPKHS-L2 (11mm/40mm) (4mm/14mm) 1.50"/3.00" 0.50"/1.5" (38mm/75mm) (12mm/38mm) TPKHS-A3 1.40"/2.40" 0.50"/1.13" TPKHS-B3 (36mm/60mm) (12mm/28mm) 0.90"/1.70" 0.30"/0.80 TPKHS-H3 (22mm/43mm) (8mm/20mm) 2.00"/3.20" 0.75"/1.40" (50mm/80mm) (19mm/35mm) TPKHS-J4 1.40"/2.65" 0.43"/1.20" (36mm/67mm) (11mm/30mm) TPKHS-K6 1.45"/2.40" 0.35"/0.80" (37mm/61mm) (9mm/20mm) 11
12 TEMPERATURE CONTROL SensorTube Factory installed SensorTube provides a 1/4" or 3/8" OD x wall tube as a raceway in the heated core of the bundle. The bundle requires no special installation methods. RTDKIT20 100Ω/100PT three wire RTD with 20ft (6m) leads and cord grip / locknut. Insert the bulb in the bundle in direct contact with the process tube or tubes. Cut three pieces of the 2" (50mm) wide fiberglass insulating tape about 1" (25mm) less than the length of the slit. For each piece, fold the tape along the cut length making a double layer tape of 1" (25mm) wide. Work each of the three tapes into the slit covering the capillary bulb and under the jacket material. TYPEJKIT20 TYPEKKIT20 Type J thermocouple with 20ft (6m) leads. Type K thermocouple with 20ft (6m) leads. Use the fiberglass tape supplied with the jacket patch kit to wrap the bundle over the slit every 1 1 /2" (40mm). Secure the capillary to the bundle with the tape for a distance of at least 2" (50mm) from the end of the slit. Apply a liberal bead of sealant, similar to TPKSK, along each side of the capillary. Factory Installed Temperature Sensors Identify if your bundle was supplied with factory installed temperature sensors. See "Model Number and Product Identification" Locate the leads as they exit the bundle. RTD leads may be supplied with an armor flex cable which will contain: 1 - Red lead 2 - White leads Use the black rubber patch supplied with the jacket patch kit and wrap the bundle to seal the slit. Cut the black rubber patch so that it extends 2" (50mm) past the slit in both directions. Remove the protective backing and wrap it around the patch area, overlapping it, and press into place. Wire the switch to the power supply and the tracer per local and applicable codes. Thermocouple leads may be supplied with a common overjacket. Type Overjacket +Lead -Lead J Brown or Yellow White Red K Brown or Yellow Yellow Red Connect the leads according to the instruction provided with the controller. Field Installed Temperature Sensors Route the capillary or lead wires along the bundle away from heat sources other than the tracer in the bundle. Ensure that the location you select for the temperature sensor is in a heated section of the bundle. Check that the electric tracer is properly connected and terminated and that it is safe to temporarily energize the heater cable. Energize the heater. Using your hand feel along the area of the bundle where you will install the temperature sensor to see if it gets warmer. You should be able to feel the bundle warm up. Disconnect the tracer and proceed with the installation. Locate the tracer in the bundle. The tracer can usually be felt through the bundle and insulation. Make a slit lengthwise along the bundle, opposite the tracer, where the sensor will be placed. The slit should be about 2" (50mm) longer than the length of the sensor and it must go through the insulation and mylar. 2017, by AMETEK, Inc. All rights reserved QLT-STACKINST 3 FEB 2017 BELGIUM BRAZIL CHINA SINGAPORE SOUTH KOREA RUSSIA USA sales.obrien@ametek.com
INSTRUCTIONS. for ZONE HEATERS STACKPAK
Contents Page Model Number and Identification 2-3 Receiving and Storage 4 Installation Minimum Installation Temperature 4 Planning Installation and Determining Length with Zone Heaters 4-5 Uncoiling and
More informationTubeTrace Tubing Bundles
for Custom CEMS and Analytical Umbilicals English Units Receiving, Storing and Handling... 1. Inspect materials for damage incurred during shipping. Report damages to carrier for settlement. 2. Identify
More information3.0 INSULATED AND HEAT TRACED TUBING BUNDLE
1.0 SCOPE This specification is to be used for: 1.1 Instrument winterizing and protection of field mounted transmitters, manifolds and associated piping when the process fluid is subject to freezing. 1.2
More informationMIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS
MIQ INSTALLATION INSTRUCTIONS MIQ CATALOGUE REF. NO. Example: D / MIQ-50E3H-2S / 200 / 1404 / 120 / 4 / 12 / 6 Design (A,B,D,E) Cable Reference Length (Feet or Meters) Watts Volts Cold Lead Length (Feet
More informationPower Connection Kit installation instructions
Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
More informationRTB Tubing Bundles Installation Guide. Heating solutions for instrument and small-diameter process lines
RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines WARNING: Fire and shock hazard. Raychem heat-tracing systems must be installed correctly to ensure
More informationNuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket
Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner
More informationPRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)
PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire
More informationInstallation Instructions
K-Series Constant-Wattage Heating Cable Installation Instructions Read and understand this material before installing this heater. Failure to understand how to safely install the heater could result in
More informationWarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing
WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife
More informationInstallation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES
Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) TRACING S CONTENTS page Constant Watt Cable Self-Regulating Cable SECTION 1. OVERVIEW 1.1 Precautions... 2 1.2 Cable and components...
More informationFLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES
FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.
More informationIntroduction to Heat Trace Cable Systems
Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).
More informationPictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...
Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss
More informationPIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM
PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace pipe freeze protection or flow maintenance system. For
More informationRaychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions
Raychem CSJA 1521 Cold-Shrinkable Splice for single core polymeric insulated (XLPE-EPR) cables up to 15kV for tape, wire, Unishield, LC shield, JCN, and flat strap neutral cable UniShield is a trademark
More informationSpecification for Heated Instrument Tubing in Process Applications* (March 29, 2007)
Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) 1.0 SCOPE This specification outlines the minimum requirements for electrically traced or steam/fluid traced instrument
More informationInstrument and Heat Trace Tubing Products
Instrument and Heat Trace Tubing Products Fluid & Gas Handling Non-Insulated Non-Insulated Metal Tube products Plastic tube products MJ Metal Tube Jacket PJ Plastic Tube Jacket Single metal tubing jacketed
More informationVITALink Taped Splice Pigtail Crimp
A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice
More informationPower-Limiting Cables
Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your
More informationElectric Heat Tracing INSTALLATION PROCEDURES
Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing Complete Electric Heat Tracing System... Illustration A: Typical Heat Tracing Installation A complete electric heat tracing system will
More informationTSRT TSRT Tee Splice Kit Installation Instructions
TSRT TSRT Tee Splice Kit Installation Instructions Description The TSRS Splice Connection Kit is for use with all versions of EasyHeat s self regulating heater cables smaller than 0.44 (11mm) in diameter.
More informationTerminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES
Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Terminator DP/FAK-5LHT The following installation procedures are suggested guidelines for the
More informationC A Heating Cable Gland Kit Installation Instructions
C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a
More informationUPC Power Connection Kit
Installation Instructions UPC Power Connection Kit For Self-Regulating & Constant Wattage Heating Cables PJ495-5 161-562581-029 January 2017 2 UPC Power Connection Kit Self-Regulating & Constant Wattage
More information3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination
3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may
More informationC A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS
C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a
More informationSPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions
SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P with Pyrotenax MI heating cable using required MI cable grounding kit SPC-P with Raychem
More information3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits
3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.
More informationVIPAK Contents Page INSTRUCTIONS
Contents Page General Installation Instructions 2 Mounting Kits 3- Factory Installed Mounting Kits Mounts 6 Brackets 6 Steam and Electric Heaters 7 Mounting Steam Heaters 7 Wiring Electric Heaters 7 Mounting
More informationSelection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &
More informationHeating Cable. Description
203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal
More informationC Power Connection Kit
1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is
More informationInstallation Instructions Mineral Insulated (M.I.)
Installation Instructions Mineral Insulated (M.I.) trace ASSEMBLY Contents page Section 1. Overview 1.1 Precautions... 2 1.2 M.I. cable and components... 2 1.3 General accessories... 3 1.4 Tools required...
More informationHeating Cable. Description
203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths
More information3M Self Regulating Heating Cables
2 Construction & Function 3M Self Regulating Heating Cables Introduction: 3M Canada and Thermon Manufacturing Company have entered into a strategic alliance to market the commercial line of heat tracing
More informationHeating Cable. Description
Single Entry Power Connection Kit NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Lighted or Non-Lighted Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power, Splice or Tee Connection
More informationTerminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES
Elbow Splice Kit for Electrically Heated TubeTrace Bundles The following installation procedures are suggested guidelines for the installation of the Kit. Receiving, Storing and Handling 1. Inspect materials
More informationTerminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES
Terminator DP/HT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Terminator DP/HT The following installation procedures are suggested guidelines for the installation
More informationType HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations
E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More informationFrost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor
Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient
More informationPipe Freeze Protection Design/Install Guide
Pipe Freeze Protection Design/Install Guide Page 1 of 16 Pipe Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 STEP 1 Information Required Page 4 STEP 2 Design Considerations Page
More informationUltrasonic Two-Wire Point Level Control
Ultrasonic Two-Wire Point Level Control General Instructions The Ultrasonic Point Level Control indicates liquid presence/absence within a sensor cavity. Two piezoelectric crystals face each other across
More informationHeating Cable. Cut to Length in Field. Description
Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection
More informationQAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA
QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA eltherm Canada Inc. 1440 Graham s Lane, Unit 5 Burlington Ontario L7S 1W3 Canada Phone: +1 (289) 812-6631 Fax: +1 (844) 325-6750 E-Mail:
More informationEMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions
EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating
More informationEcoflex potable PEX plus pre-insulated pipe system Installation guide
Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system installation guide l 1 Uponor Ecoflex potable PEX plus pre-insulated pipe system
More informationTerminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles
Terminator ZP/ Kit Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Listed Cable System 137M Terminator ZP/ The following installation procedures are suggested guidelines for the installation
More informationType LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations
F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive
More informationJBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions
JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions Description The JBS-100-STB is a NEMA 4X rated power connection kit. It is designed for use with Raychem BTV-CR, BTV-CT,
More informationTerminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES
for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of the Terminator DP/FAK-4 and FAK-4L
More informationInstructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)
Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE IN THE OPTI-GUARD SPLICE ENCLOSURE (HEXACORE CABLE DESIGNS) NOTE: EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT, THESE DRAWINGS AND/OR SPECIFICATIONS
More informationXL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance
XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal building solutions WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK
More informationTrough, Wireway & Strut Attributes
Trough, Wireway & Strut Trough, Wireway & Strut Stahlin offers a broad range of auxiliary products designed to complement a full non metallic wiring system. Wire management through a corrosion resistant
More informationType LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations
A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the
More informationInstruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.
Instruction Manual for Heating Cables and Cold Leads Type 68994- and 68997- Catalogue no. 68994- and 68997- Hemstedt GmbH Schleicherweg 19 D-74336 Brackenheim-Botenheim Phone +49 (7135) 9898-0 Fax +49
More informationSERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL
SERIES 35-72 120 VAC Microprocessor Based Direct Spark Ignition Control 35.72.03 FEATURES Two Mounting Configurations Open Board With Stand-Off's - saves space and cost Potted - protection for washdown
More informationFREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework
FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation
More informationSeismic Sensor Accessories SA, SV & ST 6000 Series
Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28
More informationSelf-Regulating Freeze Protection Heating Cable
D PDS SRF Self-Regulating Freeze Protection Heating Cable E C B A Output Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Freeze Protection of
More informationE E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.
5 YEAR WARRANTY 5 YEAR WARRANTY COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS E354088 LISTED AC E354088 58VDC E354088 E354088 5 5 YEAR WARRANTY 5 YEAR WARRANTY E354088 Caution: Observe precautions for
More informationWARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.
Tetra Contour LS LED Lighting System GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1 Installation Guide 24 Volt BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT
More informationMotor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)
Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables) Instructions Kit Contents 3 Lug Covers 3 Cold Shrink Terminations 12
More informationRosemount Multipoint Thermocouple and RTD Profiling Sensors
Product Data Sheet FEATURES Efficiently monitor a temperature profile for a wide range of applications, including hot-spot detection in reactors Single process insertion for up to 60 independent measurement
More information3M Cold Shrink Splice Kit QS-III 5536A
3M Cold Shrink Splice Kit QS-III 5536A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric
More informationHVS S 15kV Class
Product HVS-3-1580S 15kV Class Transition Splice for 3/C to 3/C Extruded Dielectric (Poly/EPR) Power Cables Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526 PII-54864, Rev
More informationFlexible Heaters. Silicone Rubber Heaters
Rugged, yet thin, lightweight and flexible the use of Watlow silicone rubber heaters is limited only by the imagination. With these heaters, heat can be put where it is needed. In the application process
More informationPre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL
Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A
More informationFAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES
High Temperature End Seal Kit The following procedures are guidelines for the installation of the FAK-7HTS High Temp. End Seal Kit. Receiving, Storing and Handling... 1. Inspect materials for damage incurred
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationJBM-100-STB NEMA 4X-rated connection kit Installation Instructions
JBM-100-STB NEMA 4X-rated connection kit Installation Instructions Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box Approvals Hazardous Locations CLI,
More informationCold Shrink QS T Trifurcating Transition Splice Kit
Cold Shrink QS2012-13-3T Trifurcating Transition Splice Kit Instructions IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice Cable Size Range Requirements PILC 500 kcmil Conductor Size (240 mm 2
More informationWarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES
WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES WarmTrace TM HSX Safety Comes First... The safety and performance of a heat tracing system depends on how the system was designed,
More informationHOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines
HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines PVC jacket - Deg C (optionally PUR material) Glass fibre thermal insulation Process tube(s) Heat reflective tape Electrical heating
More informationJBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS
JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS DESCRIPTION The JBS-100-A and JBS-100-A6 are NEMA 4X-rated power connection kit. It is designed for use with Raychem
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
ECOLUX 6608 Series 6608/5 Explosion Protected Fluorescent Emergency Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationELB ES. Product Installation Instructions
ELB-25-210-ES 200A 25kV Class Loadbreak Elbow with Integral Jacket Seal for Copper Tape (CT) and Jacketed Concentric Neutral (JCN) cables Product Installation Instructions Safety Instructions When installing
More informationJEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market
1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter
More informationTerminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables
Lighted Power Connection / Lighted End Termination Kit Installation Instructions Terminator DL-L for use with RSX, TSX, VSX self-regulating heating cables Terminator DL-S for use with BSX *, HTSX, KSX
More informationTOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure
Part Number: PT791-0T099 Kit Contents Item # Quantity Reqd. Description 1 1 Trailer Wire Harness Module 2 1 4-Flat Harness 3 1 Battery Power Wire Harness 4 1 Mounting Bracket, 4-Flat 5 2 Screw #10-24 6
More informationNAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION
Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet
More informationFLEXTRACE. FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration. Applications. Characteristics
FSG.GB/07/05.07 FLEXTRACE TEMPERATURE MAINTENANCE SYSTEMS www.flexelec.com FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration Characteristics Can be cut to length on site. Will not
More informationTOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure
Part Number: PT791-0T099 Kit Contents Item # Quantity Reqd. Description 1 1 Trailer Wire Harness Module 2 1 4-Flat Harness 3 1 Battery Power Wire Harness 4 1 Mounting Bracket, 4-Flat 5 2 Screw #10-24 6
More informationFlex Tube. User guide
Flex Tube User guide CONTENTS INTRODUCTION...2 Welcome 2 Safety 2 INSTALLATION...3 Flex Tube orientation 3 Bending a Flex Tube 4 Cutting a Flex Tube 4 Connection and mounting kits 5 Feed cable kit 5 End
More informationHotset High-Watt Density Cartridge Heaters
Cartridge Heaters hotset High-Watt Density Cartridge Heaters Hotset High-Watt Density Cartridge Heaters proven technology founded on our long term experience with many outstanding advantages. For applications
More informationSure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards
049-289 Sure-Lites Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. WARNING Risk of Fire/Electric Shock If not qualified, consult an electrician. WARNING Risk
More informationSelf-Regulating Cables
Self-Regulating 1. Self- Regulating 2. Power- Limiting This step-by-step design guide provides the tools necessary to design a self-regulating heat-tracing system for insulated pipes and tubing. For other
More informationInstallation & Operation Instructions. Type USL Signal Light Kit for Self-Regulating Constant Wattage Heating Cables. Constant Wattage Grommet
Chromalox Installation & Operation Instructions DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE SECTION RT (Supersedes PF477-1) PJ937 161-562581-032 DECEMBER, 2007 Type USL Kit for Self-Regulating Constant
More informationHWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES
HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES THERMAL MANAGEMENT SOLUTIONS WWW.THERMAL.PENTAIR.COM Important Safeguards and Warnings
More informationQUICKTERM TERMINATION KIT
PYROTENAX QUICKTERM TERMINATION KIT INSTALLATION INSTRUCTIONS FOR TERMINATING SINGLE CONDUCTOR COPPER SHEATHED MINERAL INSULATED CABLE DESCRIPTION This termination kit is used to terminate #6 AWG and larger
More informationTerminator DP/FAK-5 and FAK-5L
for T-Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of the Terminator DP/FAK-5 and FAK-5L:
More informationPre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL
Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A
More information/ CABLE TIES & WIRE FASTENERS /
Standard Self-locking Cable Ties information INFO Melting point: 265 C (509 F) Brittleness temperature: -112 C (-169 F) at 2% water Provide up to 50% more tensile strength and 15% larger bundle diameters
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
, INC. ECOLUX 6600 Series 6600/5 Explosion Protected Fluorescent Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationUnderground Bus Bar Distribution System 03 SEP 13 Rev B
Application Specification 114-24006 Underground Distribution System 03 SEP 13 NOTE NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters
More informationDEVI EasyConnect Heating Cable Connection System
Installation Instructions DEVI EasyConnect Heating Cable Connection System IP 68 0 mm 10 20 30 40 50 60 70 80 90 100 110 120 Standards: DIN VDE 0606 T200, DIN EN 61984 (VDE 0627), VDE 0110 IEC 60999; CSA:
More informationAluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors
Application Provide a liquidtight and strain relief termination for flexible type neoprene, hypalon, and PVC jacketed power or control cord and cable. For use in wet or dry locations sealing electrical
More informationTerminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles
Terminator ZP/ Kit Electrically Heated TubeTrace Bundles Listed Cable System 17M Terminator ZP/ The following installation procedures are suggested guidelines for the installation of the Terminator ZP/
More information