Seismic Sensor Accessories SA, SV & ST 6000 Series
|
|
- Herbert Lambert
- 5 years ago
- Views:
Transcription
1 Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28 mount accelerometers. Rain tight & ex-proof for CSA Class 1, Grps A-D, Div.1. 1/4 NPT stud for mounting to machine case. 1 NPT top conduit union. Zinc Plated Flange Mount For surface mounting of 7295 housing. 1/4 NPT center hole. 3 equally spaced 6.6 (.26) dia. mount holes on 38 (1.50) dia. circle XXXX Magnetic Mount Magnetic Mount Bulk Cable Mounting Pad SA6200A-X0X; SV6300A-001 SA6200A-X1X; SV6300A SA6200A, ST6900 Series & SV6300A Strong rare earth magnet provides up to 16 kg [35 lbs] pull force for temporary mounting of 1/4-28 tapped accelerometers. Housing has 1/4-28 center hole & includes sensor mounting stud. Same as except metric version. Housing has M6X1 center hole and comes with matching sensor mounting stud..250 dia. bulk cable with twisted, shielded pair wires. For customer attachment to mating connector P/N Specify - XXXX in 0.1 m increments (e.g =25.0 m ). Mounting pad for magnet, 1 Polyurethane Jacketed , Accelerometer EP Housing Assembled Disassembled Flange Mount , Mounting Pad, XXX Magnetic Mount 125 mm [5.0 in.] Weight: 0.7 kg [1.5lb] Weight: 0.5 kg [1 lb] Weight: 0.5 kg [1 lb] Weight: kg [0.5 lb] 2.28
2 Seismic Sensor Accessories SA, SV & ST 6000 Series Mating Connector/Cable Assemblies XXXX, Splashproof Cable Assembly Two (2) pin socket connector with integral, molded splash proof boot with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters XXXX-YYYY, Splashproof Cable Assembly w/ Armor Two (2) pin socket connector with integral, molded splash proof boot with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters XXXX, Cable Assembly Two (2) pin socket connector with cable strain relief with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. Note: All 8978 connector/cable assemblies rated to 121 o C (250 o F) max XXXX-YYYY, Cable Assembly, w/ Armor Two (2) pin socket connector with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters , Connector Assembly Two (2) pin socket connector with cable strain relief, no cable , Mounting Stud 1/4-28 UNF to 1/4-28 UNF , Mounting Stud 1/4-28 UNF to M6 X , Mounting Stud 1/4-28 UNF to 3/8-24 UNF , Mounting Stud 1/4-28 UNF to 1/4-18 NPT , Sensor Spot Facing Kit Tool with a 3/16 pilot and drill bits and taps NOTE: All 8978 connector/cable assemblies rated to 121 C (250 F) max. 2.29
3 Seismic Sensor Accessories Probe Driver / Signal Conditioner / Transmitter Housings Features Provides physical protection NEMA 4/IP 65 Models for 2, 4 or 8 units Conduit terminations (when used) Hazard rated - 2 or 4 unit models Metrix Product Applications 1 Signal Conditioner Models 5534 & 5544 (Pg 2.12) 5535 & 5545 (Pg 2.06) Signal Condtioner Models 5510, 5516 (Pg 1.26) Proximity Probe Transmitter Models TXA & TXR (Pg 1.20) Probe Driver Model 5533 (Pg 1.18) 1 Products (ordered separately) to be DIN-rail mount to fi t enclosures. Weatherproof Versions Polyester coated steel housing with gasketed cover and stainless steel clips comes with conduit hubs and DINrail/s for mounting Metrix Instrument Co. products. NEMA 4/IP 65 Model shown - 2 units (max. capacity) 1 NPT EXIT (Model 7876) (Model 8172) 1 1/4 NPT (Model 8173) 3/4 NPT ENTRY (QTY 2 for 7876) (QTY 4 for 8172) (QTY 8 for 8173) with 1 unit Explosionproof Versions Cast aluminum housing with threaded cover & DIN-rail/s for mounting Metrix Instrument Co. products. NEC & CSA rated for Class I, (C,D) & Class II (E, F & G), Div.1 areas. ATEX rating EEx d IIC T5 or T6. Explosionproof Model shown - 2 units (max. capacity) 3/4 NPT 1/2 NPT ATEX How To Select... Model Environmental Rating Units Empty Weight Dimensions in mm (inches) Weatherproof 2 2 kg (4.4 lb) 200 x 250 x 100 (8 x10 x 4) Weatherproof 4 3 kg (6.6 lb) 250 x 300 x 125 (10 x 12 x 5) Weatherproof 8 4 kg (8.8 lb) 300 x 350 x 150 (12 x 14 x 6) Explosionproof 2 5 kg (11 lb) 178 x 178 x 163 (7 x 7 x 6.4) Explosionproof 4 11 kg (24 lb) 280 x 229 x 190 (11 x 9 x 7.5) Note: Customized and pre-wired housings available upon request. Please contact us for more information. 2.30
4 Velocity Sensor Accessories 5485C PART NO. NAME USED WITH DESCRIPTION Mounting 5485C 1/4-28 mount adaptor - loose with screws and stud. (0.2 Kg) Mounting Same as -001 except shipped attached to sensor XXX, Mounting 2.31
5 Transmitter Accessories ST5484E, ST5491E , Conduit Elbow & Reducer Provides access and physical protection for fi eld wiring. Suitable for Class I, Div. 1 (Grps C & D) and Class II, Div. 1 (Grps E, F & G), hazardous areas. 1 to ¾ NPT reducer for customer connection included. NEMA 4 IP 65. Material: copper free aluminum , Conduit Elbow & Reducer Conduit Elbow with terminal block , Conduit Elbow & Reducer Provides access and physical protection for fi eld wiring , Conduit Elbow & Reducer Conduit Elbow with terminal block , Conduit Union Fits between transmitter and conduit elbow to facilitate installation and wiring where there is not enough room to rotate the elbow. Suitable for Class I, Div. 1 (Grps A, B, C & D) and Class II, Div. 1 (Grps E, F & G), hazardous areas. Material: zinc plated steel , Flange Mount Provides a means to surface mount transmitters rather than NPT stud (½ : NPT center hole). Three equally spaced 6.6 mm (0.26 ) diameter mounting holes on 38 mm (1.50 ) diameter circle , Flange Mount Same as , except center hole is ¼ NPT. Material: stainless steel , Bushing Bushing for ½ NPT mount when screwed onto standard ¼ NPT base. Material: stainless steel XXX, Two-wire, Cable Assembly 2 conductor (20 AWG) twisted, shielded PVC jacketed cable, with plated steel grip for cable strain relief, male ¾ NPT end. Specify -XXX for length in feet. Example: =10 ft (3.1M). Material: zinc plated steel XXXX, Splashproof Cable Assembly Two (2) pin socket connector with integral, molded splash proof boot with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters XXXX-YYYY, Splashproof Cable Assembly w/ Armor Two (2) pin socket connector with integral, molded splash proof boot with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters XXXX, Cable Assembly Two (2) pin socket connector with cable strain relief with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. Note: All 8978 connector/cable assemblies rated to 121 o C (250 o F) max XXXX-YYYY, Cable Assembly, w/ Armor Two (2) pin socket connector with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters , Connector Assembly Two (2) pin socket connector with cable strain relief, no cable , Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Diameter range:.156 to.25. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures , Armored Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Armor diameter range:.40 to.50. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures. 2.32
6 Transmitter Accessories ST6900 Series & IT XXXX, Splashproof Cable Assembly Two (2) pin socket connector with integral, molded splash proof boot with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters XXXX-YYYY, Splashproof Cable Assembly w/ss armor Two (2) pin socket connector with integral, molded splash proof boot with 7.1 mm (0.28 ) diameter, ss armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters XXXX, Cable Assembly Two (2) pin socket connector with cable strain relief with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. Note: All 8978 connector/cable assemblies rated to 121 o C (250 o F) max XXXX-YYYY, Cable Assembly, w/ Armor Two (2) pin socket connector with 7.1 mm (0.28 ) diameter, ss armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters , Connector Assembly Two (2) pin socket connector with cable strain relief, no cable , Mounting Stud 1/4-28 UNF to 1/4-28 UNF , Mounting Stud 1/4-28 UNF to M6 X , Mounting Stud 1/4-28 UNF to 1/4-18 NPT , Mounting Stud 1/4-28 UNF to 3/8-24 UNF , Mounting Stud 1/4-28 UNF to 1/4-18 NPT Note: These mounting studs are also used for 2-pin MS connector style accelerometers 2.33
7 Transmitter Accessories PMC/BETA 162VTS , Flange Mount Provides a means to surface mount transmitters rather than NPT stud (½ : NPT center hole). Three equally spaced 6.6 mm (0.26 ) diameter mounting holes on 38 mm (1.50 ) diameter circle , Flange Mount Same as , except center hole is ¼ NPT. Material: SS , Bushing Bushing for ½ NPT mount when screwed onto standard ¼ NPT base. Material: stainless steel XXX, Two-wire, Cable Assembly 2 conductor (20 AWG) twisted, shielded PVC jacketed cable, with plated steel grip for cable strain relief, male ¾ NPT end. Specify -XXX for length in feet. Example: =10 ft (3.1M). Material: zinc plated steel , Conduit Elbow & Reducer Provides access and physical protection for fi eld wiring. Suitable for Class I, Div. 1 (Grps C & D) and Class II, Div. 1 (Grps E, F & G), hazardous areas. 1/2 to 1/2 NPT reducer for customer connection included. NEMA 4 IP 65. Material: copper free aluminum , Conduit Elbow Conduit Elbow with terminal block, 1/2 to 1/2 NPT female. Supporting Accessories for MS Style Connector , Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Diameter range:.156 to.25. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures , Armored Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Armor diameter range:.40 to.50. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures , 1 to 1/2 Reducer Retrofit adapter 2.34
Proximity Transmitters, and Seismic Vibration Transmitters
TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The
More informationGeneral Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG
More informationNUMBER SIDE VIEW DESCRIPTION RANGE DIAMETER C F in. pf/ft. Coaxial, low noise, orange, PVC jacket
NUMBER SIDE VIEW DESCRIPTION RANGE DIAMETER C F in. pf/ft. J1 Coaxial, low noise, orange, PVC CABLES 55 to 80 67 to 176 0.088 cables & connectors J3 Coaxial, low noise, high temperature, red, Teflon 100
More informationELECTRICAL INSTALLATION
ENCLOSURE DIMENSIONS NOTES (3) 3/4" NPT WALL MOUNT BRACKET, (2) 5/16" DIA. THRU - HARDWARE IS CUSTOMER SUPPLIED 1¼" NPT AUTO-TEST OPTION 6.312" 160.3 mm 4.85" 123 mm 3.90" 99 mm 4.95" 126 mm 4.85" 123
More informationProximity Transducers, Seismic Sensors and Accessories
ProvibTech s Case Mount Sensors Selection Guide Model Number Sensitivity TM0782A TM0783A TM0786A General Purpose Accelerometer TM0784B TM0793V TM079VD Low Power Accelerometer Velocity Transducer 100 mv/g
More informationShell material Insulator Contacts Sealing Temperature Mating Protection
Technical Data Shell material Machined components: die cast components: Shell plating: Cable entry: Copper-Zinc alloy (CuZn) Zinc (GD-Zn) Nickel (Ni) plated max. 10 mm Insulator Connector inserts: Polyamid
More informationCable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:
QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which
More informationPPT 802, Proximity Probe Transducer System
PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current
More informationProximity Transmitters, and Seismic Vibration Transmitters
Introduction TM016 Velocity/ Acceleration Vibration Transmitter The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The
More informationEPIC CIRCON M23 Series
M23 Series EPIC EPIC CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland
More informationCable Glands & Accessories
Cable Glands & Accessories This catalog features ITC s extensive range of liquid-tight, strain relief cord connectors (cable glands) and accessories, including locknuts, sealing washers, plugs, etc. These
More informationGeneral Cable Support Information
General Cable Support Information Applications Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels, or other devices
More informationSKINNER Intrinsically Safe Series Four-Way
SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air
More informationNTC Thermistor Assemblies
FEATURES Standard and custom assemblies are available in a variety of configurations Assemblies can conveniently attach to or be an integral part of any system to monitor or control temperature No added
More informationJunction Boxes Hazardous and Non-Hazardous
Junction Boxes Hazardous and Non-Hazardous Description Page No. Application/Selection 112 Boxes Flush EGJ Series 19 WJBF Recessed Sidewalk Cover Series 116 Service Station EGJ Series 19 GUA Series 17 GUP
More informationCATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories
CATENARY ACCESSORIES INSTRUCTIONS Quick Connect Jumper Cord AY-QC7P6-X Sheet 2 Quick Connectors AY-QC7SET Sheet 3 3/32" Stainless Steel Cable AY-CBL3/32-50 Power Cord AY-P6-50 Power Cord Ties AY-WT-100
More informationUser s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition
User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement
More informationSAMPLE. Job Name: Anywhere Water District Construction of Reservoir Suggest'd Equipment Rent Total. Suggest'd Material.
Job Name: Anywhere Water District Construction of Reservoir 1500 Anywhere Water District Construction of Reservoir 1500 Electrical Contractor Sub Bid Qty #Elect Hours Unit Underground Conduit Work $60/hr
More informationRosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications
Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof
More information200150, & Accelerometers Bently Nevada* Asset Condition Monitoring
200150, 200155 & 200157 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 20015x Accelerometers are general purpose, wide frequency, case-mounted seismic transducers designed for
More informationSection 3 Index Furnace Tube Skin Thermocouples
Section 3 Index Furnace Tube Skin Thermocouples Thermocouple Assemblies Model Page O1 Bare End Terminations 3-1 O2 Lead Wire Extension 3-2 O3 SS Flex Armor Extension 3-3 O4 CGB Over SS Flex Armor 3-4 Thermocouple
More informationand Accelerometers Bently Nevada* Asset Condition Monitoring
200350 and 200355 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 200350 and 200355 Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster*
More informationCaution. Description. Specifications and Ordering Information and Accelerometers
R Specifications and Ordering Information 200350 and Accelerometers Description The 200350 and Accelerometers are general purpose, case-mounted seismic transducers designed for use with Trendmaster Pro
More informationPassive Speed Sensors
5/8 18 FAMILY General Purpose 70085-1010-001 1.125 (28.57) 70085-1010-003 2.625 (66.67) 70085-1010-018 3.625 (92.07) 70085-1010-118 5.000 (127.00) (Select cable from group A, see index) Output Voltage
More informationW Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications
W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications This table shows the optional items available on the different types of enclosures shown in this
More informationand Accelerometers
200350 and 200355 Accelerometers Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 200350 and 200355 Accelerometers are general purpose, casemounted seismic transducers designed
More informationExplosionproof NEC. Features
Quantum Rotary Control Monitors Explosionproof NEC Low power single or dual-coil rotary control monitors certified Explosionproof for use in hazardous areas. They are available with a broad range of integrated
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
GEMS COMPLIANT 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 00 psi to 0-0,000 psi ranges (0- bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationLiquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat
Liquid Tight Connectors Reusable Fittings Industrial specification grade, screw machined steel, zinc plated UL Rated Liquid Tight Includes sealing washer Bonds conduit to box or enclosure Corrosion resistant
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need
More informationV200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating
V200 Positioner Housing Material: Cast aluminium with polyester coating Indicator Options: Flat pointed indicator or raised indicator (red/green or yellow/black) One housing for pneumatic or electropneumatic
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationLevel instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.
Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate
More informationGlass Reinforced Polyester Enclosures
42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,
More informationHot Tap Insertion Vortex
Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design
More informationTERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS
OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface
More informationCastle Model TSM-35. Heavy Duty Screw Pocket Machine. For Models with Serial Number and Above Items Included with Machine
Castle Model TSM-35 Heavy Duty Screw Pocket Machine For Models with Serial Number 63658 and Above Items Included with Machine Part No. Description Qty B02964 9/64" Castle Premium Brad Point Drill Bit w/
More informationHKH Series. HAZCON Controls for Harsh and Hazardous Environments
HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More informationPVC Couplings. Brass Couplings BRASS COMPRESSION COUPLING 3 -LENGTH PVC COMPRESSION COUPLING BRASS COMPRESSION COUPLING 5 -LENGTH
& FITT Brass Couplings BRASS COMPRESSION COUPL 3 -LENGTH 46331 3/8 1/2 12 120 5.80 46332 1/2 3/4 12 120 7.38 46333 3/4 1 6 72 10.52 46334 1 1 1/4 6 60 13.44 46335 1 1/4 1 1/2 4 48 18.00 46336 1 1/2 4 36
More informationGO gets it. The all in one proximity sensor and limit switch.
The all in one proximity sensor and limit switch. GO gets it. GO Switch is the most versatile sensing solution. It detects like a proximity switch and functions like a limit switch, providing higher reliability
More informationAPPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin
Updated 09.11.16 APPLICATION MANUAL Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin Contents: 1. Destination. 2. Flameproof joints, process
More informationTemperature Sensors Types MBT 5250, MBT 5260 and MBT 5252
MAKING MODERN LIVING POSSIBLE Data sheet Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252 MBT 5250 MBT 5260 MBT 5252 Heavy-duty temperature sensors for controlling cooling water, lubrication oil,
More informationLTX RF LEVEL SENSOR. Instruction Manual
LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004
More informationFluidizing Pickup Tube Kits
Instruction Sheet P/N 303787-02 Introduction The fluidizing pickup tube kit retrofits your existing mobile powder system with fluidizing air. It injects fluidizing air at the pickup tube inlet with minimal
More informationSensor Mounting MACHINERY MONITORING. Mounting Configurations. Temporary Mounting
Sensor Mounting When using Piezoelectric sensors to measure vibration, the sensor must directly contact the machine surface. The more intimate and stiff the contact between sensor and the machine, the
More informationInsulator Connector inserts: Polyamide (PA66) UL 94 V0 All connectors with different shielding material for different jacket and shield diameters.
Technical Data Shell material Machined components: die cast components: Shell plating: Cable entry: Copper-Zinc alloy (CuZn) Zinc (GD-Zn) Nickel (Ni) plated max. 18 mm Insulator Connector inserts: Polyamide
More informationCam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.
Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok
More informationExplosion Proof & Hazardous Area Junction Boxes
CSA - Class I Div. 1 - Groups C & D * CSA - Class I Zone 1 - Groups IIA, IIB * * Applies to GUI boxes only Explosion Proof & Hazardous Area Junction Boxes Features: Heavy-duty copper free (below 0.04%)
More informationConductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 DR20022 Cable Support Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category DR20022
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationMyers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural
Applications: Myers Hubs are used in the termination of electrical circuits through wall of the enclosure Designed for use indoors or outdoors with rigid conduit and IMC Ideal for pharmaceutical, chemical
More informationShock/Vibration Control Switches
Shock/Vibration Control Switches Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 ` Installation Instructions 00-02-0185 2013-02-01 Section 20 Please read the following information before installing.
More informationAmphenol Cable Glands and Cord Grips Amphenol
Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30
More informationD-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries
Contents Page D-Sub adapter... 40.02 Han Split Hood... 40.04 Cable entry protection with metric cable entries... 40.06 Cable entry protection with Pg cable entries... 40.08 Coding for Hoods/Housings and
More informationAPS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION
page 1 DESCRIPTION The switch boxes are suitable for rotary actuators and are the industry leader in versatility, quality and approvals gained. Models include APS standard range with a variety of outputs
More informationSolar Combiner Solutions
Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from
More informationRosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries
Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationPIT, PIF & PIX. Features. Pressure-to-Current Transmitters
R, PIF & PIX May 2010 Description Moore Industries family of pressure-to-current transmitters provide an economical solution when a pneumatic device must interface with a data acquisiton/control system,
More informationWire Mesh. Flexible Cord. Liquid Tight Mesh Grips for Flexible Metal Conduit STR GT Series
58 We have taken our excellence and combined quality steel mesh to create the best grips in the industry. American Fittings cable grip and cord grip bodies are safe and strong in any industrial environment.
More informationA LOOK INSIDE MODEL 7 TECHNOLOGY IN ACTION 70 Series LEVERLESS LIMIT SWITCH GO Switch 70 Series end sensing switches use three permanent magnets and p
AirOil Systems, Inc. Round Sensors A LOOK INSIDE MODEL 7 TECHNOLOGY IN ACTION 70 Series LEVERLESS LIMIT SWITCH GO Switch 70 Series end sensing switches use three permanent magnets and pushpull plunger
More informationType 2000 Transducer Product Instructions
Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationEXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable
More informationMICRO-CON-X 2-7 NEW PRODUCT BULLETIN C708
FEATURES & BENEFITS Up to 7 contacts in compact design IP-67 rating, at the face (when mated) IP-67 molded cable assemblies (when mated) All plastic design is light weight Variety of standard options to
More informationamericanfittingscorp.com t: e:
Reusable Fittings / Straight Connectors Size Range: 3/8 to 5 Liquid Tight Connectors Reusable Fittings Industrial specification grade, screw machined steel, zinc plated UL Rated Liquid Tight Includes sealing
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationINTERNATIONAL METAL ENGINEERING
INSTRUMENT ENCLOSURES, JUNCTION BOXES, STOPPING PLUGS, TEMPERATURE ASSEMBLIES AND A WIDE RANGE OF INDICATORS, TRANSMITTERS AND BATCH CONTROLLERS FM, CSA, ATEX, IECEx CERTIFIED OCTOBER 2015 INTERNATIONAL
More informationField IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage
Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use
More informationElectronic Temperature Sensor
Connection Head Type RTD or Element or RTD Cast Aluminum, Polypropylene or Stainless Steel Head Weather Proof Welded or Spring Loaded TDD TMD Hot Junction: Head Process Connection Conduit Connection 100Ω
More informationUser s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)
User s Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals by electronic
More informationParts Catalog. S-Series Slicer Standard Automatic S13A. Model:
, 07 99508 ECN 06 Parts Catalog S-Series Slicer Standard Automatic Model: SA SA //07 Rev. L IMPORTANT! TO EXPEDITE SHIPMENT OF PARTS, ALWAYS SPECIFY MODEL, REV, PART NUMBER, AND SERIAL NUMBER OF UNIT.
More informationKuhlman Electric Corporation Volt Instrument Transformers
Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight
More information24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A
24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A Part #: EXP-IP-POE-INJ-24V-24W Page: 1 The EXP-IP-POE-INJ-24V-24W from Larson Electronics is an Explosion
More informationMetal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Industrial Application
Metal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Straight, Male 45, Male 90, Male Straight, Female Straight, Cable Hose, Male Straight Swivel Fittings Ferrules for Fittings Further Accessories Applications
More informationJunction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety
JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50
More information180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223
METRIC (IEC) FRAME THYRISTOR RATED DC METRIC (IEC) FRAME MOTORS IP54 These metric dimensioned motors are built to IEC 34-1 electrical and mechanical standards. The IEC 63 and smaller frames are stocked
More informationCable Festoon Systems - For Moving Machinery
Cable Festoon Systems - For Moving Machinery CONDUCTIX offers a comprehensive range of Cable Festoon Systems to power moving machinery. Our festoon systems are ideal for supporting, protecting, and managing
More informationPoint level measurement Capacitance switches
Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.
More informationAC METRIC (IEC) MOTORS THREE PHASE
These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools, textile machinery
More informationSwagelok Ball Valve Actuation Options
www.swagelok.com Swagelok Ball Valve Actuation Options Rack and pinion pneumatic actuators, solenoid valves, and limit switches ISO 5211-compliant pneumatic actuators, solenoid valves, limit switches,
More informationCANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*
27295 8/11/03 T 7:42 AM Page 1 E M P O S O N I C S R S E R I E S CANBUS 550541 G P r o d u c t S p e c i f i c a t i o n s PARAMETER S P E C I F I C AT I O N Measured Variable: Resolution: Non-Linearity:
More informationCorrosion Protection for Electrical Conduit and Fittings
Easy access for pulling, splicing, mounting and maintenance! 3 4" LB Form 8 conduit body and cover 2 1 2" LB Form 8 conduit body and cover OCAL-BLUE Double-Coat Conduit Bodies With OCAL-BLUE Double-Coat
More informationForm 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.
For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
More informationW-Series Junction Boxes
W-Series Junction Boxes Application and Selection Junction boxes, designed for hazardous and non-hazardous locations, are used in a variety of industries to perform the following functions: As a pull box
More informationMP461SC Flex Probes* Installation Instructions
PNEUMERCATOR Liquid Level Control Systems MP461SC Flex Probes* Installation Instructions Model MP461SC Magnetostrictive Flex Probes For use with the following consoles: TMS2000 TMS3000 NOTE: MP461SC PROBES
More informationSolenoid Valves Type 3963
Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate
More informationHKH Series. HAZCON Controls for Harsh and Hazardous Environments
(93) A ø 0.2" (ø 5.5) 1.9 (4 3.7" (93) B A " 0) 8" 0) HKH Series HAZCON Controls for Harsh and Hazardous Environments 0.2" (5.5) 0.2" (5.5) 3.1" (80) 2.8" (70) ø 0.2" (ø 5.5) 1.9" (48) 3.7" (93) A B 0.2"
More informationArmstrong In-Line and Insertion Vortex Flow Meters
Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line
More informationTransmitter Housing Model: CET5000-G CET5000-P CET5000-P. Optional Extended cable For Remote Mounting. (6 or 12 feet length)
Model CET5 Series SmartCET Corrosion Monitoring Transmitter single variable output version CET5-G General Corrosion CET5-P Localized Corrosion (Pitting) 34-SC-03-01 11/06 Specification and Model Selection
More informationFIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications
FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together
More informationTemperature Transmitters
Termination BAPI recommends using twisted pair of at least 22AWG and sealant filled connectors for all wire connections. Larger gauge wire may be required for long runs. All wiring must comply with the
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals
Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents
More informationSeries 581 ISO Pneumatic Directional Control Valves
Series 581 ISO 5599-1 Pneumatic Directional Control Valves Series 581 Pneumatic Valves 01_1 st Headline_36 pt/14.4 mm 4-Way ISO Directional Control second line Series 581 - A complete series of standardized
More informationuse pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics
Lines 2, 3 and 4 and line quantities applicable to SSx mounting only Project: Type: Qty: FIT # qty SERIES - OPTICS - MOUNTING - LIGHT ENGINE - CCT - FINISH - VOLTAGE - ACCESS.1 - ACCESS.2 1 OLML- - - -
More information