ELECTRICAL INSTALLATION

Size: px
Start display at page:

Download "ELECTRICAL INSTALLATION"

Transcription

1 ENCLOSURE DIMENSIONS NOTES (3) 3/4" NPT WALL MOUNT BRACKET, (2) 5/16" DIA. THRU - HARDWARE IS CUSTOMER SUPPLIED 1¼" NPT AUTO-TEST OPTION 6.312" mm 4.85" 123 mm 3.90" 99 mm 4.95" 126 mm 4.85" 123 mm 4.625" 117 mm FRONT VIEW SIDE VIEW 1) Enclosure Ratings: Nema-3,4X,7 & 9 UL Standard 1203 CSA Standard C FM Class No NEC CLASS I, Groups B, C & D CLASS II, Groups E, F & G CLASS III 2) Enclosure Material: Light weight corrosion resistant copper-free aluminum construction with sand blast finish. Painted with flat epoxy, gold in color. Neoprene gasket. 2 5/8" dia. viewing window. 3) When transmitter is used in classified areas, an x-proof seal should be used as required by electrical code. The cable entry into the enclosure must be sealed with BOSS 315 RTV ATI p/n: , or equivalent multipurpose sealant. If conduit is used, it must also be sealed internally at the entry point to the housing. ELECTRICAL INSTALLATION LOOP POWER LOOP POWER GROUND TERMINAL GROUND JUMPER ( ) EARTH GROUND (OR CONDUIT) LOOP POWER 18 or 20 GAUGE WIRE RECOMMENDED GND TERMINAL LOCATED NEXT TO RELAY BASE RELAY BASE SENSING MODULE CONNECTOR ( ) ROUTE GRAY, VIOLET, AND BLUE WIRES UNDER GROUND JUMPER SENSING MODULE (GAS SPECIFIC) AUTO-TEST OPTION 8 COND. SHIELDED CABLE TO SENSING MODULE CONNECTOR SS-A12RH.PMD, DATE: 11/9/10, DRAWN: KJN, APPD: Page 1 of 8

2 TRANSMITTER ASSEMBLY UniSens TRANSMITTER MODULE EXPLOSION PROOF ENCLOSURE RELAY BASE PLUG TRANSMITTER MODULE INTO THE RELAY BASE VIA THE RELAY PLUG MOUNTED ON THE BOTTOM OF THE TRANSMITTER MODULE. SENSING MODULE CONNECTOR ( ) INSURE LOCK RING IS TURNED FULLY TO THE LEFT. INSTALL SENSING MODULE SNAP-LOCK CONNECTOR INTO SENSING MODULE CONNECTOR. TURN SENSING MODULE TO THE RIGHT, UNTIL IT SNAPS IN PLACE. TURN LOCKING RING TO THE RIGHT UNTIL IT STOPS. THIS LOCKS THE SENSING MODULE TO THE SENSING MODULE CONNECTOR. SNAP-LOCK CONNECTOR LOCK RING SENSING MODULE (GAS SPECIFIC) AUTO-TEST OPTION WALL MOUNT BRACKET INSTALLATION WALL MOUNT BRACKET ( ) (2) S.S x 1/4" FHMS ( ) SUPPLIED BY ATI BACK VIEW Page 2 of 8

3 TRANSMITTER ASSEMBLY with REMOTE SENSOR (GAS SPECIFIC) Page 3 of 8

4 TRANSMITTER ASSEMBLY with DUCT SENSOR ATI-0335 Page 4 of 8

5 D10 (NO Auto-Test) SENSOR CALIBRATION ADAPTER ASSEMBLY ( ) ATI-063 Page 5 of 8

6 D28 (w / Auto-Test) SENSOR CALIBRATION ADAPTER ASSEMBLY ( ) ATI-0501 Page 6 of 8

7 D10 FLOWCELL ASSEMBLY ( ) ATI-0462 Page 7 of 8

8 G10 INSERTION PROBE (SENSING POSITION) ATI-0298 G10 INSERTION PROBE (CALIBRATION POSITION) 1) To place sensor into the Calibration position, slowly back the sensor out of the housing, until you here a click and the sensor doesn't move any more. The sensor is now positioned to be calibrated. Attach tubing to barb fitting, and proceed with calibration. When calibration is complete, the sensor is now ready to be placed back into the sensing position. To do this pull up on the locking pin, and slide the sensor in a little bit release the pin,then continue to slide the sensor all the way into the pipe. The sensor is now in operation again. ATI-0299 Page 8 of 8

Seismic Sensor Accessories SA, SV & ST 6000 Series

Seismic Sensor Accessories SA, SV & ST 6000 Series Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28

More information

CATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories

CATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories CATENARY ACCESSORIES INSTRUCTIONS Quick Connect Jumper Cord AY-QC7P6-X Sheet 2 Quick Connectors AY-QC7SET Sheet 3 3/32" Stainless Steel Cable AY-CBL3/32-50 Power Cord AY-P6-50 Power Cord Ties AY-WT-100

More information

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC. NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/upgrades. Allows connection of straight conduit runs, branch

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors,

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments

More information

PIT, PIF & PIX Pressure-to-Current Transmitters

PIT, PIF & PIX Pressure-to-Current Transmitters R, PIF & PIX October 2017 Description Moore Industries family of pressure-to-current transmitters provide an economical solution when a pneumatic device must interface with a data acquisiton control system,

More information

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator Table of Contents Page Introduction... 1 Description... 1 Specifications... 2 Installation... 3 Calibration... 4 General Maintenance...

More information

Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air

Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air Infinity Duct & Immersion Temperature Sensors Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air temperature and fluid as part of an Andover Controls building automation

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections

More information

Section 3 Index Furnace Tube Skin Thermocouples

Section 3 Index Furnace Tube Skin Thermocouples Section 3 Index Furnace Tube Skin Thermocouples Thermocouple Assemblies Model Page O1 Bare End Terminations 3-1 O2 Lead Wire Extension 3-2 O3 SS Flex Armor Extension 3-3 O4 CGB Over SS Flex Armor 3-4 Thermocouple

More information

MAXIGARD A2000 SPEED SWITCH. Introduction

MAXIGARD A2000 SPEED SWITCH. Introduction A107-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A2000 SPEED SWITCH Introduction The Maxigard A2000 Speed Switch is designed to monitor

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

T38 1 T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com

More information

SIGNET Temperature Transmitter

SIGNET Temperature Transmitter SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

PRO REMOTE Series CAPACITANCE PROBE

PRO REMOTE Series CAPACITANCE PROBE Price $5.00 PRO REMOTE Series CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

TMS Series MP46x Flex Probes* Installation Instructions

TMS Series MP46x Flex Probes* Installation Instructions PNEUMERCATOR Liquid Level Control Systems TMS Series MP46x Flex Probes* Installation Instructions Model MP461, MP462 And MP463 Magnetostrictive Flex Probes Installation For: MODEL TMS2000 and MODEL TMS3000

More information

Explosionproof NEC. Features

Explosionproof NEC. Features Quantum Rotary Control Monitors Explosionproof NEC Low power single or dual-coil rotary control monitors certified Explosionproof for use in hazardous areas. They are available with a broad range of integrated

More information

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters R, PIF & PIX May 2010 Description Moore Industries family of pressure-to-current transmitters provide an economical solution when a pneumatic device must interface with a data acquisiton/control system,

More information

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION SURFE/CEILING & SUSPENDED MOUNT INSTALLATION E477827 E477827 APPLICATION NL luminaires are designed for use indoors, outdoors, wet locations, areas containing moisture, dirt, corrosion, vibration and rough

More information

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610-0012 Rev B Manual No. 610-0012 REV B Neo-Dyn 28150 Industry

More information

TS Series TS Series

TS Series TS Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com TS-6700-850 Series TS-5700-850 Series Electronic Remote Temperature Sensors General Instructions APPLICATION Electronic thermistor

More information

Flow Computer Installation

Flow Computer Installation Flow Computer Installation WARNING: Only personnel who are experienced with field wiring should perform these procedures. All field wiring must conform to the National Electrical Code, NFPA 70, Article

More information

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide

More information

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240

More information

Bourdon Tube Pressure Switches

Bourdon Tube Pressure Switches DA /DS Bourdon Tube es Visible setpoint, adjustable deadband, snap action switch pressure ranges to 000 psi Weather-Proof Types DAW, DSW, DRW -/1 2-1/1 REAR MOUNTING FLANGE ().20 DIA. HOLES AT 120 ON -1/2

More information

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610-0014 E Manual No. 610-0014 Rev E Neo-Dyn 28150 Industry Drive

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Design Benefits Up to 100 mm (4 inch) gap between target and

More information

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections

More information

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors

More information

LIMIT SWITCHES & POSITION INDICATION

LIMIT SWITCHES & POSITION INDICATION LIMIT SWITCHES & POSITION INDICATION Engineering Creative Solutions for Fluid Systems Since 1901 TECHNOPOLYMER LIMIT SWITCH DESCRIPTION The Pratt Industrial MS41-2 Limit Switch Box represents a new dimension

More information

SG1000A Slide Gate Sensor Slide Gate & Valve Position

SG1000A Slide Gate Sensor Slide Gate & Valve Position SG1000A Slide Gate Sensor Key Features Measures multi-turn shaft angle (rotational) position Translates linear position to 4-20 ma output Configurable measurement range (0-1/4 turn to 0-6 turns) Direct

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5. TABLE OF CONTENTS PAGE SPECIFICATIONS 3 INSTALLATION 4 Direct Mount 4 Ducted Installations 5 Installing Plenum 5 Machine Mount Stand 5 Ceiling Mount 6 Pedestal Stand 7 Drain Installation 7 Electrical 8

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

GE Sensing & Inspection Technologies

GE Sensing & Inspection Technologies GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for

More information

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

LB125A 1-1/4 LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB125A 1-1/4" LB Form 5 Aluminum Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION INTRODUCTION Scope This manual provides instructions for the installation, adjustment, maintenance, and parts ordering of the P200 Pneumatic-to-Current P/I Transducer. Due to its over-engineered design,

More information

Temperature Transmitters

Temperature Transmitters Termination BAPI recommends using twisted pair of at least 22AWG and sealant filled connectors for all wire connections. Larger gauge wire may be required for long runs. All wiring must comply with the

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

TE-6300 Series Temperature Sensors

TE-6300 Series Temperature Sensors TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued July 14, 2008 Supersedes November 13, 2006 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

Super-Safe-Plus Roto-Bin-Dicator

Super-Safe-Plus Roto-Bin-Dicator Super-Safe-Plus Roto-Bin-Dicator for your most demanding applications... Offers both mechanical and electronic sensing in one reliable Point Level Sensor... Level control with added confidence Under normal

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

RESISTIVITY MONITOR/CONTROLLERS

RESISTIVITY MONITOR/CONTROLLERS RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189

More information

m WARNING! READ m BEFORE INSTALLATION

m WARNING! READ m BEFORE INSTALLATION m WARNING! READ m BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure, excessive vibration or pressure pulsation, excessive instrument temperature,

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches Dual Hi-Lo pressure switches are rugged, field-mounted instruments. The pressure sensing assemblies are conventional Static O Ring type. The main difference is that two sensing assemblies share a common

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the CO level and outputs a 4-20 ma signal. The standard product features a 2- wire loop-powered output. Optionally, the device

More information

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

Motion sensors. Milltronics MFA 4p 6/17. Overview

Motion sensors. Milltronics MFA 4p 6/17. Overview Siemens AG 2013 Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the

More information

Instrument Enclosure Assemblies

Instrument Enclosure Assemblies Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s

More information

Applications. Illustrated Features

Applications. Illustrated Features Applications For use in locations where a high degree of corrosion resistance is required. FR Series: For use in areas where high humidity or water vapor are present Typical uses include meat- or food-processing

More information

TE-6300 Series Temperature Sensors

TE-6300 Series Temperature Sensors TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued April 7, 2010 Supersedes March 13, 2009 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Model 550 Series Vibration Switches

Model 550 Series Vibration Switches OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE: ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,

More information

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband P-SERIES Temperature Switches Switches for -30 through 5 F with Adjustable Set Points and Fixed or Adjustable Features: Set point repeatability, + F (/2 C). All wiring terminals, adjustments and visual

More information

CML Electric Actuator for Baumann Series

CML Electric Actuator for Baumann Series Electronic Actuators Product Bulletin CML Electric Actuator for Baumann 4000 Series CML-50 and CML-750 electronic modulating valve actuators feature state-of-the-art brushless DC motor technology to provide

More information

T Series Temperature Sensors with Linitemp Product Overview

T Series Temperature Sensors with Linitemp Product Overview TS Sensors with initemp roduct Overview temperature sensors are available with linitemp output. devices come with several mounting options, including duct, wall, ceiling, outdoor, remote, and immersion.

More information

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS SLC-811X Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Single Loop Proportional Temperature Controller General Instructions APPLICATION Electronic temperature controller

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A 24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A Part #: EXP-IP-POE-INJ-24V-24W Page: 1 The EXP-IP-POE-INJ-24V-24W from Larson Electronics is an Explosion

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values

More information

Explosionproof NEC. Fully integrated and encapsulated rotary valve position monitors that are certified for use in explosive atmospheres.

Explosionproof NEC. Fully integrated and encapsulated rotary valve position monitors that are certified for use in explosive atmospheres. AccuTrak Rotary Position Monitors Explosionproof NEC Fully integrated and encapsulated rotary valve position monitors that are certified for use in explosive atmospheres Features Touch set cams are hand

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed

More information

WARNING! READ BEFORE INSTALLATION

WARNING! READ BEFORE INSTALLATION A4 INTRINSICALLY SAFE & NON-INCENDIVE RATED PRESSURE TRANSMITTER INSTRUCTION SHEET WARNING! READ BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure,

More information

1000 Series Piston Type Differential Pressure Gauges

1000 Series Piston Type Differential Pressure Gauges 1000 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Rosemount 3051S Electronic Remote Sensor (ERS) System

Rosemount 3051S Electronic Remote Sensor (ERS) System Rosemount 3051S Electronic Remote Sensor (ERS) System The Rosemount 3051S ERS System is a flexible, 2-wire 4-20 ma ART architecture that calculates differential pressure (DP) electronically using two pressure

More information

DC MOTORS NEMA FRAME SCR RATED

DC MOTORS NEMA FRAME SCR RATED NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223 METRIC (IEC) FRAME THYRISTOR RATED DC METRIC (IEC) FRAME MOTORS IP54 These metric dimensioned motors are built to IEC 34-1 electrical and mechanical standards. The IEC 63 and smaller frames are stocked

More information

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box 1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic

More information

PRO REMOTE 25 LV CAPACITANCE PROBE

PRO REMOTE 25 LV CAPACITANCE PROBE Price $5.00 PRO REMOTE 25 LV CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26

More information

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD CONTROL PANEL MOUNTING PAGE No. 74 NUMBER: LS-240V1PH-TCU-VFD 35 38 47 U A 9 33 V 26 24 25 41 43 7 7 44 ALUMINUM BACKPLATE 41 42 50 46

More information

EPOXY POWDER COATED COPPER FREE ALUMINUM

EPOXY POWDER COATED COPPER FREE ALUMINUM 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AJA510 Alum MTG Unilet Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

Transmitter Housing Model: CET5000-G CET5000-P CET5000-P. Optional Extended cable For Remote Mounting. (6 or 12 feet length)

Transmitter Housing Model: CET5000-G CET5000-P CET5000-P. Optional Extended cable For Remote Mounting. (6 or 12 feet length) Model CET5 Series SmartCET Corrosion Monitoring Transmitter single variable output version CET5-G General Corrosion CET5-P Localized Corrosion (Pitting) 34-SC-03-01 11/06 Specification and Model Selection

More information

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections

More information

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A Automation, Inc. Model EAC1100 /A QUICK INSTALL GUIDE Advanced Outdoor Airflow Control, DCV Control and Alarm Solution Enhancer QUICK INSTALL GUIDE for ENHANCER Advanced Outdoor Airflow Control, DCV Control

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information