Signet Pressure Transmitter

Size: px
Start display at page:

Download "Signet Pressure Transmitter"

Transcription

1 Signet 80 Pressure Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation. Specifi cations. Electrical Connections. Menu Functions Pres:. psi Pres:. psi. Installation ProcessPro transmitters are available in two styles: panel mount and fi eld mount. The panel mount is supplied with the necessary hardware to install the transmitter. This manual includes complete panel mounting instructions. Field mounting requires one of two separate mounting kits. The 80 integral kit joins the sensor and instrument together into a single package. The 800 Universal kit enables the transmitter to be installed virtually anywhere. Detailed instructions for integral mounting or other fi eld installation options are included with the 80 Integral kit or the 800 Universal kit.. Panel Installation. The panel mount transmitter is designed for installation using a ¼ DIN Punch. For manual panel cutout, an adhesive template is provided as an installation guide. Recommended clearance on all sides between instruments is inch.. Place gasket on instrument, and install in panel.. Slide mounting bracket over back of instrument until quickclips snap into latches on side of instrument.. To remove, secure instrument temporarily with tape from front or grip from rear of instrument. DO NOT RELEASE. Press quickclips outward and remove. panel gasket terminals mounting bracket 9 mm (.8 in.) Optional 80 9 mm Rear 9 mm (.8 in.) Cover (. in.) latch System Pwr Loop System Pwr Loop Output Output 7 Sensr Gnd (SHIELD) Sensr IN (RED) Sensr V (BLACK) 9 mm (.8 in.) FRONT VIEW Field Mount & Panel Mount mm (.7 in.) mm (. in.) 07 mm (. in.) SIDE VIEW Field Mount mm (. in.) mm (. in.) 97 mm (.8 in.) SIDE VIEW Panel Mount Panel Mount Installation Detail quickclips. Specifications General Compatibility: Signet 0 Pressure Sensor Accuracy: ±% of full scale Enclosure: Case: PBT Panel case gasket: Neoprene Window: Polyurethane coated polycarbonate Keypad: Sealed key silicone rubber Weight: Approx. g ( oz.) Display: Alphanumeric x LCD Update rate: second Contrast: User selected, levels Electrical Power: to VDC ±0%, regulated, 0 ma max current Sensor Input: Range: 00 psig, 07 bar, 0700 kpa Current output: to 0 ma, isolated, fully adjustable and reversible Max loop impedance: 0 Ω V, Ω 8 V, 00 Ω V Update rate: 00 ms Accuracy: ±0.0 ma Opencollector output: Hi, Lo, Off, Programmable: Optically isolated, 0 ma max. sink, 0 VDC max. pullup voltage Hysteresis: User adjustable Environmental Operating temperature: 0 C to 70 C ( F to 8 F) Storage temperature: C to 80 C ( F to 7 F) Relative humidity: 0 to 9%, noncondensing Maximum altitude: 000 m ( ft) Insulation category: II Rating: NEMA X/IP front Standards and Approvals CE, UL listed Immunity: EN008 Emissions: EN0 Class B Manufactured under ISO 900 for Quality, ISO 00 for Environmental Management and OHSAS 800 for Occupational Health and Safety. Declaration of Conformity according to FCC Part This device complies with Part of the FCC rules. Operation is subject to the following two conditions: () This device may not cause harmful interference, and, () This device must accept any interference received, including interference that may cause undesired operation. China RoHS (Go to for details)

2 . Electrical Connections Caution: Failure to fully open terminal jaws before removing wire may permanently damage instrument. Wiring Procedure. Remove mm mm (0. in. 0. in.) of insulation from wire end.. Press the orange terminal lever downward with a small screwdriver to open terminal jaws.. Insert exposed (noninsulated) wire end in terminal hole until it bottoms out.. Release orange terminal lever to secure wire in place. Gently pull on each wire to ensure a good connection. Wiring Removal Procedure. Press the orange terminal lever downward with a small screwdriver to open terminal jaws.. When fully open, remove wire from terminal. Wiring Tips: Do not route sensor cable in conduit containing AC power wiring. Electrical noise may interfere with sensor signal. Routing sensor cable in grounded metal conduit will help prevent electrical noise and mechanical damage. Seal cable entry points to prevent moisture damage. Only one wire should be inserted into a terminal. Splice double wires outside the terminal. If your system uses a single sensor, it must be located within m (00 ft.) of the transmitter. If your system uses two sensors, the total length of cable connected to the transmitter is limited to m (00 ft.) The conductors from a dualsensor system can be tied together and then a single set of wires continued on to the transmitter. For best performance, ground the sensor SHIELD wire to a local earth ground at a point near the sensor. (Experiment with connecting the sensor shield wire to different local ground points to identify best signal quality.) : Primary Loop Power VDC ±0% system power and current loop connections. SINGLE SENSOR system MUST use terminals. : VDC ± 0% Power and current loop connections for second sensor. Maximum loop impedance: 0Ω max. at V Ω max. at 8 V 00Ω max. at V : Dual digital sensor inputs See next page for more information. Loop 0 Output Snsr Gnd (WHITE) Loop Snsr IN (RED) System Pwr Loop 9 Output Snsr V (BLACK) System Pwr Loop 8 Output Snsr Gnd (WHITE) AUX Power AUX Power 7 Output Snsr IN (RED) Snsr V (BLACK) : Auxiliary power is used only if two sensors are connected to the transmitter. Internal opencollector output circuit S Outputs _ Isolation D 70: OpenCollector Outputs Two transistor outputs programmable as High or Low alarm with adjustable hysteresis Outputs can be disabled (Off) if not used Signet 80 Pressure

3 . Sensor Input Connections Jbox Pressure Cal: 0.0 psi > C A White (Snsr Gnd) Red (Snsr IN) Black (Snsr V) White (Snsr Gnd) Red (Snsr IN) Black (Snsr V) Signet 0 Pressure Sensors Pressure Cal: 0.0 psi > m (00 ft.) A B C m (00 ft.) B B Pressure Cal: 0.0 psi > A A B m (00 ft.). System Power/Loop Connections Standalone application, no current loop used Loop Loop System Power Loop System Power Loop Connection to a PLC/Recorder, separate supply AUX Power AUX Power AUX power required only where two sensors are used NC NC Power Supply VDC Connection to a PLC with builtin power supply Loop Loop System Power Loop System Power Loop AUX Power AUX Power AUX power required only where two sensors are used Example: Two transmitters connected to PLC/Recorder with separate power supply PLC or Recorder Channel 0 ma Channel 0 ma Power Supply VDC Loop Loop System Power Loop System Power Loop AUX Power AUX Power PLC or Recorder Channel 0 ma in Channel 0 ma in Channel 0 ma in Channel 0 ma in Internal PLC Connection PLC Channel 0 ma Channel 0 ma Power Supply VDC AUX power required only where two sensors are used Loop Loop Loop Loop System Power Loop System Power Loop AUX Power AUX Power AUX power required only where two sensors are used Signet 80 Pressure Power Supply VDC System Power Loop System Power Loop AUX Power AUX Power

4 . Open Collector Output The Open Collector output can be used as a switch that responds when the process variable moves above or below a setpoint. Low: Output triggers when process variable is less than the setpoint. The output will relax when the process variable moves above the setpoint plus the hysteresis value. High: Output triggers when process variable is greater than the setpoint. The output will relax when the process variable moves below the setpoint plus the hysteresis value. Process Delta Pressure (Differential Mode) If two sensors are connected to the transmitter, the DELTA (Sensor Sensor ) can be assigned to output. To enable differential mode, the selected output's "Source" selection must be set to "DP". For pressure and temperature transmitters ensure Sensor is equal to ID : Sensor Sensor Difference = 0 Sensor (80) Example: 0 ma Loop Source: DP Loop Range: 00 Loop: =.00 ma Sensor (0) Hysteresis Low Setpoint Time Example: Output Output Source: DP Output Mode: Low Output Setpoint: 70 Output = ON Output energized Output deenergized Process High Setpoint Hysteresis Time VIEW menu During normal operation, the ProcessPro displays the VIEW menu. When using the CALIBRATE or OPTIONS menus, the ProcessPro will return to the VIEW menu if no activity occurs for 0 minutes. To select the item you want displayed, press the UP or DOWN arrow keys. The items will scroll in a continuous loop. Changing the display selection does not interrupt system operations. No keycode is necessary to change display selection. Output settings cannot be edited from the VIEW menu. Pres: Pres:. psi. psi View Menu Display Press: 7.89 psi Press:. psi Delta Pressure:. psi Description Monitor Pressure and Pressure simultaneously. This is the permanent view display. Monitor the delta pressure (Channel rate channel rate = Delta Pressure) This is a permanent display. The displays below are temporary. After 0 minutes the display returns to the permanent display. Loop Output:.00 ma Loop Output: 7. ma Last CAL: 0009 Monitor the to 0 ma output for Loop and. Monitor date for scheduled maintenance or date of last calibration. (See description in Calibrate Menu.) Signet 80 Pressure

5 ProcessPro Editing Procedure: Step. Press and hold key: seconds to select the CALIBRATE menu seconds to select the OPTIONS menu. Step. The Key Code is UPUPUPDOWN keys in sequence. After entering the Key Code, the display will show the fi rst item in the selected menu. Step. Scroll menu with UP or DOWN arrow keys. Step. Press RIGHT ARROW key to select menu item to be edited. The fi rst display element will begin fl ashing. Step. Press UP or DOWN keys to edit the flashing element. RIGHT ARROW key advances the fl ashing element. Step. Press key to save the new setting and return to Step. Notes on Step : The View Menu is normally displayed. The CALIBRATE and OPTIONS menus require a KEY CODE. Notes on Step : If no key is pressed for minutes while display is showing "Enter Key Code", the display will return to the VIEW menu. Press & hold for access: CALIBRATE: Enter Key Code CALIBRATE: Enter Key Code VIEW CALIBRATE s s CALIBRATE: Enter Key Code CALIBRATE: Enter Key Code OPTIONS Switch ID: > First item in CALIBRATE menu Notes on Steps and : Refer to pages and 7 for complete listing of menu items and their use. From the Step display, pressing the UP and DOWN keys simultaneously will return the display to the VIEW menu. If no key is pressed for 0 minutes, display will also return to the VIEW menu. Switch ID: > Step Step : Finished Editing? Press the UP and DOWN keys simultaneously after saving the last setting to return to normal operation. Output Setpnt: 0.00 psi > Step Notes on Steps and : All output functions remain active during editing. Only the fl ashing element can be edited. RIGHT ARROW key advances the fl ashing element in a continuous loop. Edited value is effective immediately after pressing key. If no key is pressed for 0 minutes unit will restore the last saved value and return to step. Step (pressing key) always returns you to Step. Repeat steps until all editing is completed. Output Setpnt: 0.00 psi Output Setpnt: psi Output Setpnt: psi Step Step : Made an Error? Press the UP and DOWN keys simultaneously while any element is fl ashing. This will recall the last saved value of the item being edited and return you to Step. Output Setpnt: psi Step Output Setpnt: psi > Output Setpnt: Saving Signet 80 Pressure

6 Calibrate Menu Display (Factory settings shown) Description Switch ID PSI Pressure Units: psi > Set: Pressure Set: Pressure Loop Source Pressure Loop Range: psi > Output Source Pressure Output Mode: Low > Output Setpnt: 0.0 psi > Output Hys: > Last CAL: 009 Reverses the identifi cation of Sensor inputs: Pressure becomes identifi ed as Pressure, Pressure becomes identifi ed as Pressure. Use this function to make corrections if the sensors are in the wrong order for a DELTA PRESSURE measurement. Select Pressure units for both input channels: psi, bar or kpa. Provides a maximum psi offset to match 80 to external reference. Enter 999 to restore the original Factory calibration value. Changes to this setting will become effective when the display exits the Calibrate menu. Select the INPUT SIGNAL represented by this 0 ma output: Pressure, Pressure, or Delta Pressure (Pressure Pressure.) Check the 0 Sensor instructions for the range capability of your sensor. Be sure to modify this setting if you change the Pressure Units. Select the INPUT SIGNAL represented by this Open Collector Output: Pressure, Pressure, or the Delta Pressure (Pressure Pressure.) Select the desired mode of operation for the Open Collector output. Options available are High or Low. The signal may be disabled (Off) if not used. In Low or High Mode, the Open Collector output # will be activated when the pressure reaches this value. Be sure to modify this setting if you change the Pressure Units. The Open Collector output will be deenergized at Setpoint ± Hysteresis, depending on High or Low Setpoint selection. Use this note pad to record important dates, such as annual recertifi cation or scheduled maintenance. Menu items will repeat for Loop and Output. Signet 80 Pressure

7 Options Menu Display (Factory settings shown) Contrast: > Decimal. > Averaging Off > Description Adjust the LCD contrast for best viewing. A setting of is lowest contrast, is highest. Select lower contrast if the display is in warmer ambient surroundings. Set the decimal to the best resolution for your application. The display will automatically scale up to this resolution. Select.,.,.,. or. OFF provides the quickest output response to changes in fl ow. Longer averaging period produces more stable display and output response. Select LOW, HIGH or OFF. Output Active Low > Active HIGH: This setting is used to turn a device (pump, valve) ON at the setpoint. Output Active Low > Active LOW: This setting is used to turn a device OFF at the setpoint. Loop Adjust.00 ma > Loop Adjust 0.00 ma > Adjust the minimum and maximum current output. Use this setting to match the system output to any external device. The display value represents the precise current output. Adjustment limits:.80 ma <.00 ma >.00 ma 9.00 ma < 0.00 ma >.00 ma Test Loop : Test Loop : > Press UP or DOWN keys to manually order any output current value from. ma to.00 ma to test current loop output. > Test Output : Test Output : > Press UP or DOWN keys to manually toggle the state of open collector output. > Menu items will repeat for Loop and Output. Signet 80 Pressure 7

8 Troubleshooting Display Condition Possible Causes Suggested Solutions Check Sensor? Too much error CHECK SENSOR Reset to Factory Calibration Relay is always activated SETUP READ ERROR Press Any Key Sensor not wired properly. Sensor connected to 80 while power is on. Defective sensor. The value entered in Set Pressure fi eld is greater than psi deviation from sensor input. (The 80 allows a maximum of psi calibration offset.). Value in SET PRESSURE fi eld is 999. Hysteresis value too large Defective transmitter Memory fault occurred. Correct sensor wiring. Recycle power with all sensors connected. Replace defective sensor. Confi rm calibration values. Remove sensor from installation, check 80 reading (should be zero). If necessary, Set Pressure to zero, reinstall sensor, then recalibrate. Entering "999" in this fi eld will remove all user calibration input and restore the factory values. Change the hysteresis value Replace transmitter Press any key to reload factory presets. Reprogram all setpoints. If this message appears again, replace the 80. Ordering Information Mfr. Part No. Code Description Pressure transmitter, Field mount 80P Pressure transmitter, Panel mount Pressure transmitter, Field mount with relays 80P Pressure transmitter, Panel mount with relays Pressure transmitter, Field mount with dual input/output 80P Pressure transmitter, Panel mount with dual input/output Accessories Mfr. Part No. Code Description Universal mounting kit / in. Integral mounting kit / in. NPT mount junction box Splashproof rear cover RC Filter kit (for relay use) Heavy duty wall mount bracket Surface Mount Bracket Liquid tight connector kit for rear cover (includes connectors) Liquid tight connector kit, NPT ( piece) Liquid tight connector kit, PG. ( piece) Rev. J 0/ English

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

SIGNET Temperature Transmitter

SIGNET Temperature Transmitter SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

Signet ph/orp Transmitter

Signet ph/orp Transmitter Signet 87501 ph/orp English *38750.0901* 38750.0901 Rev. F 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18 English Signet 2450 Pressure Sensor *32450.0901* 32450.0901 Rev. 13 03/18 Product Manual Description The 2450 Pressure Sensor has a onepiece injection molded PVDF body and ceramic diaphragm for superior

More information

SIGNET 7002 Vortex Flow Sensor ENGLISH

SIGNET 7002 Vortex Flow Sensor ENGLISH SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

Signet 7000/7001 Vortex Flow Sensors * *

Signet 7000/7001 Vortex Flow Sensors * * DN X DN X DN X DN X DN X DN X DN X Signet 7000/7001 Vortex Flow Sensors *3-7000.090* 3-7000.090 Rev. F 10/05 English English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4.

More information

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations. Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 Rev. F 11/1 English For the most up-to-date information, please refer to our website at www.gfsignet.com SAFETY INSTRUCTIONS 1. Do not

More information

SIGNET 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before

More information

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Installation The VDS-1000 combines either two (2) low voltage, high side or low side, switched outputs

More information

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Installation Instructions Issue Date April 8, 2008 A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Application IMPORTANT: The A419 Series Electronic Temperature

More information

Signet 4630 Chlorine Analyzer System * *

Signet 4630 Chlorine Analyzer System * * Signet 4630 Chlorine Analyzer System *3-4630.090* 3-4630.090 Rev E 5/11 English English CAUTION! 1. Follow instructions carefully to avoid personal injury. 2. Do not exceed the maximum pressure or temperature

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

Technical Features Flow Monitor Part No. Wire Associated Sensor 4-20 ma Digital Relay Power Tech. Sensor Input Output Output Output F9.00.L 2 wire Hal

Technical Features Flow Monitor Part No. Wire Associated Sensor 4-20 ma Digital Relay Power Tech. Sensor Input Output Output Output F9.00.L 2 wire Hal FLOWX3 F9.00 Flow F9.00 FLS FLOWX3 F9.00 Flow Monitors & Transmitters are designed to convert the signal from all FLOWX3 flow sensors into a display indication and a 4-20 ma signal for long distance transmission.

More information

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet 2536 Rotor-X Paddlewheel Flow Sensors Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION... Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2

More information

Signet 2552 Metal Magmeter

Signet 2552 Metal Magmeter Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev E 07/10 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confirm chemical

More information

SIGNET Vortex Flow Sensors ENGLISH

SIGNET Vortex Flow Sensors ENGLISH DN X DN X DN X DN X DN X DN X DN X SIGNET Vortex Flow Sensors ENGLISH 37000.090 C12/00 English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4. Wiring Options Frequency Output

More information

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO Digital Paddlewheel Flow meter Operating Manual Blue-White Industries, Ltd. Page 2 TABLE OF CONTENTS 1...Introduction...2 2...Features...3 3...Model number matrix...3 4...Specifications...4 4.1..Temperature

More information

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89] Bulletin P-DM-1200 Series DM-1200 DigiMag Digital Differential Pressure and Air Flow Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations. Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 C 05/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifi cations.

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the

More information

Signet 2552 Metal Magmeter

Signet 2552 Metal Magmeter Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev D 06/08 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confi rm chemical

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

MATRIX LLC LEVEL CONTROL PANEL

MATRIX LLC LEVEL CONTROL PANEL MATRIX LLC LEVEL CONTROL PANEL Installation Operation Maintenance Manual 1-26-09 REV-0.3 1 INDEX Introduction. 3 Product Configurations..... 4 I/O Descriptions. 8 Operation o Intercooler, Accumulator,

More information

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd. MICO-FLO MICO-FLO Digital Paddlewheel Flow meter Operating Manual Blue-White Industries, Ltd. 53 Business Drive Huntington Beach, CA 92649 USA Phone: 714-893-8529 FAX: 714-894-9492 E mail: sales@blue-white.com

More information

Installation and Operation Instructions DLP Series

Installation and Operation Instructions DLP Series Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW

More information

Portable pressure calibrator, Wally Box III Model CPH7600

Portable pressure calibrator, Wally Box III Model CPH7600 Calibration technology Portable pressure calibrator, Wally Box III Model CPH7600 WIKA data sheet CT 17.01 Applications Calibration service companies and service industry Measurement and control laboratories

More information

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview Product Description The MediaGauge MG-MD is a multi-functional digital pressure gauge consisting of a media isolated piezoresistive pressure sensing element, signal conditioning circuitry for temperature

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2750 ph/orp Sensor ENGLISH ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety

More information

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator Table of Contents Page Introduction... 1 Description... 1 Specifications... 2 Installation... 3 Calibration... 4 General Maintenance...

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

EMS-2. Introduction. Features. Engine Management System. Operating Manual English 1.07

EMS-2. Introduction. Features. Engine Management System. Operating Manual English 1.07 EMS-2 Engine Management System Operating Manual English 1.07 Introduction The EMS-2 is a multifunction engine information display and early warning engine monitoring system. It has been specifically designed

More information

Tracer VMA with AutoReg

Tracer VMA with AutoReg Tracer with AutoReg Flowmeter with Automatic Flow Regulation Operating Instructions RoHS Compliant General The Tracer Flowmeter with AutoReg provides: Analog Flow Output (Selectable 0 to 3.5V, 0 to 5V

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

EZ-TRAC Digital Tension Readout and Control

EZ-TRAC Digital Tension Readout and Control Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL EZ-TRAC Digital Tension Readout and Control Table of Contents

More information

GE Sensing & Inspection Technologies

GE Sensing & Inspection Technologies GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for

More information

MondoStep 7.8. High Performance Microstepping Driver. User s Manual. Version PROBOTIX All Rights Reserved

MondoStep 7.8. High Performance Microstepping Driver. User s Manual. Version PROBOTIX All Rights Reserved MondoStep 7.8 High Performance Microstepping Driver User s Manual Version 1.0 2010 PROBOTIX All Rights Reserved Attention: Please read this manual carefully before using the driver! Table of Contents 1.

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

QUANTUM LX CONTROL PANEL

QUANTUM LX CONTROL PANEL Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor

More information

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

Signet 8150 Flow Totalizer

Signet 8150 Flow Totalizer English Signet 8150 Flow Totalizer *3-8150.090-1* 3-8150.090-1 Rev. K 9/14 English Operating Instructions Description The Signet 8150 Flow Totalizer is a battery-powered instrument capable of providing

More information

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control

More information

Chapter Page. 1 Introduction Description 1

Chapter Page. 1 Introduction Description 1 Chapter Page 1 Introduction 1 1.1 Description 1 Table of Contents 2 Calibration 3 2.1 Wet Calibration 3 2.2 Calibration Procedure 4 2.3 Installing Optional Display Board 5 2.4 Display Board Range Adjustment

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

Type A-10 General Purpose Pressure Transmitter

Type A-10 General Purpose Pressure Transmitter General Purpose TRONIC > General Purpose > A-10 Type A-10 General Purpose Pressure Transmitter Standard Features Signal output: 4-20 ma 2-wire or 0-10 V 3-wire Supply voltage: 8-30 DC (14-30 VDC) Process

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1 Installation Instructions 810701-00 Spector compact Conductivity Transmitter System LRGT 16-1 IMPORTANT NOTES...4 SAFETY NOTES...4 Danger...4 EXPLANATORY NOTES...4 Scope of supply...4 System description...4

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

Figure 1: WPR2 Dimensions and Hardware

Figure 1: WPR2 Dimensions and Hardware Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware

More information

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Electronic Pressure Measurement WIKA Datasheet PSD-10 Applications Hydraulics and pneumatics Filter monitoring Pump control

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers www.murata-ps.com Now Available with Wire Lead CTs C US E156931 FEATURES for direct measurement of 0 to 2/20/50/100 Amps Functionally complete: On-board current transformers Scaling/interface circuitry

More information

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER or TIMER

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER or TIMER Bulletin No. CUB7N-D Drawing No. LP0825 Released 09/12 MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER or TIMER C UR L US LISTED 3RSD PROCESS CONTROL EQUIPMENT 0.35" (8.9 mm) HIGH LCD DIGITS, REFLECTIVE

More information

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges and outputs 0 to 5/10 V or 4 to 20 ma. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

8000 Series Liquid Flow Meter

8000 Series Liquid Flow Meter PRODUCT DATA SHEET 8000 Series Liquid Flow Meter Advanced microprocessorbased flow measurement technology in a compact, leak-tight package. Flow ranges from 0.02 to 60 GPM / 0.1 to 227 LPM Accuracy of

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

PTC8001 Temperature Calibrator

PTC8001 Temperature Calibrator PTC8001 Temperature Calibrator Table of Contents 1. Introduction....................1 1.1 Customer Service................1 1.2 Standard Equipment..............1 1.3 Safety Information................2

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

Signet 2517 Brass Paddlewheel Flow Sensor * *

Signet 2517 Brass Paddlewheel Flow Sensor * * Signet 2517 Brass Paddlewheel Flow Sensor -250.090 English -2517.090 Rev. F 11/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

Octave Water Meter Installation Manual

Octave Water Meter Installation Manual Octave Water Meter Installation Manual 1.0 Notes For proper flow measurements, the OCTAVE s measuring tube should be completely full at all times. Non-wetted sensors show loss of signal. Though this will

More information

Digital Pressure Gauge / Pressure Switch

Digital Pressure Gauge / Pressure Switch SENSORS FOR FOOD AND BIO. Product Information MAN-90-BAT, MAN-90P-BAT FOOD Digital Pressure Gauge / Pressure Switch Application Hygienic pressure measurement Overpressure save at highest accuracy Largest

More information

DPT TARGET TYPE FLOWMETERS

DPT TARGET TYPE FLOWMETERS DPT TARGET TYPE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control S3 Patented Target/Leaf-Spring Design Minimal Wear Components 1.5-8 to 225-500 GPM Water Line Sizes 3/8 to 3" Wide

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual This IOM is for the following ProMation Engineering Products: P9-120N4 P9-230N4 P10-120N4 P10-230N4 This page intentionally left blank Field Manual P9/10 HV AC Series On/Off

More information

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor Product Identification and Overview Power and Communication on Just Two Wires Available with Temperature Sensing, Temperature Setpoint, Optional Occupant Override, Optional Display and Optional %RH Sensing

More information

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 MODEL RT INSTRUCTION MANUAL Blue-White Industries, Ltd. R PT Sarana Prima Enguna Jl.Gunung Sahari Raya 84 C - Jakarta 10610 Phone: 021-420-0045 Fax: 021-420-0483 E mail: info@spe.co.id Website:

More information

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER/TIMER

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER/TIMER Bulletin No. CUB7N-A Drawing No. LP0825 Released 04/0 MODEL CUB7 MINIATURE ELECTRIC 8 DIGIT COUNTER/TIMER 0.35" (8.9 mm) HIGH LCD DIGITS, REFLECTIVE OR TRANSMISSIVE WITH YELLOW/GREEN OR RED BACKLIGHTING

More information

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor! PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable

More information

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - Microprocessor programed specifically for optimal performance of WARM AIR systems - Large easy-to-read 40 character (x0) backlit LCD display showing

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

JUMO ecotrans Lf 01/02

JUMO ecotrans Lf 01/02 Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar Pressure Transmitter Type FM40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The measuring device for the transmitter

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values

More information

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0312 Rev B TABLE OF

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Royce Total Suspended Solids Systems. Water & Wastewater

Royce Total Suspended Solids Systems. Water & Wastewater Royce Total Suspended Solids Systems Water & Wastewater Portable and Continuous TSS Systems MODEL 711 PORTABLE MLSS/ILA SYSTEM FEATURES Two complete analyzers in one package (TSS & Interface Level) Microprocessor

More information