1 Model Q45H/62-63 Residual Chlorine Monitor...

2 ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking and cooling water systems, and a combined chlorine monitor ideally suited for chloraminated drinking water. The combined chlorine system can also be used in wastewater effluents where sufficient ammonia is present prior to chlorination to result in a predominantly monochloramine residual. Unlike on-line colorimetric and most amperometric monitors, Q45H systems utilize a membrane-covered polarographic sensor that does not require the addition of chemical reagents. That means no more costly reagents to purchase or flowcells that require frequent cleaning. All that s needed is a constant flow of water across the face of the sensor, provided by a simple constanthead flowcell. The Q45H system has no moving parts, so there are no pumps or motors that burn out or tubing breaks that create maintenance nightmares. All normal maintenance items are included with each system. The Q45H chlorine monitoring system is easy to operate, requires minimal maintenance, and will not eat a hole in your operating budget with on-going reagent requirements or component replacement costs. Features Combined Chlorine Monitor Constant Head Flowcell Free Chlorine Monitor Low Volume Flowcell No Costly Reagents Required: By eliminating the need for costly DPD and buffer reagents, the Q45H will save you money. You will also improve the work environment by eliminating the storage, handling and disposal of chemical reagents and the organic waste produced by DPD colorimetric analyzers. Lower Your Maintenance Costs: The Q45H has no moving parts, so you don t have to replace worn out tubing or failed pump modules. Automatic ph Compensation: Eliminate Free Chlorine error caused by process ph drift with the optional ph compensation feature. Available with loop-power and AC versions. Dual Measurement Capability: On AC powered units, choose the optional ph sensor and get outputs for both chlorine and ph. This feature is available with either the Free or Combined Chlorine monitors. Free or Combined Chlorine Measurement: Monitor is programmable for either type of measurement with simple sensor conversion. Loop-powered, AC, or Battery Versions: Loop-powered system available with output for chlorine measurement only. AC powered versions provide for PID, relay, and dual output functions. A unique battery operated unit with internal data logger is also available. PID Control Output: Standard PID control function can be configured quickly and easily. Flexible Range Capability: Standard Q45H monitors are programmable for display ranges of 0-2, 0-20, or PPM with analog outputs scalable within the display range to any desired value. For low level applications, a display range of PPB may also be selected.

3 Sensor Options The residual chlorine sensors are available in two configurations: flowcell and submersion. The Free Chlorine sensor should always be used in the flowcell configuration. The Constant-Head Flowcell is used to maintain a constant flow rate and pressure at the face of the sensor. The sample inlet flow rate and pressure can vary widely without affecting the measurement. The only requirement is that the sample inlet flow rate be at least 7 gallons per hour. A Low Volume Flowcell is available for clean water application with a flow rate of 3-6 gallons per hour. The Combined Chlorine sensor can be used in either the Flowcell or Submersion configuration. The submersion sensors require flow velocities of at least 0.4 ft/sec for proper operation. Optional ph Compensation For Free Chlorine Monitor Submersion and Flowcell Sensors For many applications, process ph is relatively stable, and nothing more than the standard monitor and sensor are needed. However, when the ph of the water stream varies regularly, a significant error in free chlorine concentration is introduced. This error is due to the sensitivity of the membraned sensor to wide ph fluctuations. With the simple addition of an optional ph sensor, the Q45H will automatically correct for these changes, maintaining accurate measurement even when ph varies widely or is up near a ph of 9. With AC version, this option provides a second analog output that can be assigned to ph, converting the chlorine monitor into a two parameter system, providing isolated 4-20 ma outputs for both chlorine and ph. Both Free and Combined Chlorine monitors can be converted to dual output monitors. Portable Chlorine Monitor Multiple Power Sources The Q45H is designed for exceptional flexibility to meet a variety of monitoring applications. In its simplest form, the unit is a loop-powered transmitter operating from standard 24 VDC power supplies. This means easy integration into many DCS, PLC, and SCADA systems. Loop-powered instruments include the PID output function and automatic ph correction capability. For applications where the second analog output is desired or where alarm relay functions are needed, an AC powered system is available. Operation from AC power allows the user to utilize analog outputs for both chlorine and ph, or for independent PID and chlorine outputs, or simply for chlorine and temperature outputs. For even greater versatility, a portable unit powered by a standard 9 V battery is also available. The dual VDC outputs are assignable to chlorine concentration and temperature. This instrument can be supplied with an internal data-logger, making it ideal for short term monitoring at remote sites. The unit will run for 10 days on a single battery, and the data-logger will store up to 32,000 data points, easily enough for 10 days of data at 1-minute intervals.

4 Model Q45H/62-63 Residual Chlorine Analyzer Specifications Electronic Monitor Display Range: PPB or , , or PPM Accuracy: ± 0.02 PPM or 0.5% of F.S. Repeatability: ± 0.01 PPM or 0.3% of F.S. Linearity: 0.1% of F.S. Zero Drift: < 0.01 PPM per month Display: Large 4 digit main display, 0.75" characters. 12 digit alpha-numeric second line display Power: VDC for loop-powered unit; 115/230 VAC, 50/60 Hz., 10 VA max. ; 9 VDC for battery power Control Relays: Two SPDT relays, 250 VAC, 24 VDC, resistive Relay Mode: Programmable for control or alarm function Analog Outputs: Isolated 4-20 ma, 550 ohm max. load. Two assignable 4-20 ma outputs, 550 ohm max. (AC only) Data Logger: Battery version only, stores 32,000 data points Operating Conditions: C, 0-95% R.H. non-condensing Enclosure: NEMA 4X (IP-66) polycarbonate wall, panel, or pipe mount Weight: 5 lbs. (2.3 Kg.) with sensor and flowcell Sensor & Flowcell Sensor: Wetted Materials: Sensor Cable: Response Time: Temperature Limits: Flowcell Material: Sample Flow Rate: Sample Inlet: Sample Drain: Membrane-covered polarographic sensor Noryl and 316 Stainless Steel 25 feet (7.5 M) standard, 100 feet (30 M) maximum 90% in 60 seconds 0-50 C Clear acrylic 7-15 GPH ( LPM) 1/4" I.D. hose barb 1/2" I.D. hose barb Ordering Information: Model Q45H-A-B-C-D Chlorine Monitor Suffix A - Measurement Type 62 - Free Chlorine 63 - Chloramines Suffix B - Power 1-24 VDC, 2-wire (single output only) VAC with 2 relays and 2 outputs VAC with 2 relays and 2 outputs 4 - Battery Operated with two VDC outputs Suffix C - Sensor Style 1 - Sensor with constant head flowcell and 25' cable 2 - Submersible sensor with 25' cable (Chloramine sensor only) 3 - Sensor with sealed low-volume flowcell 4 - Sensor with 1-1/2" Flow T (Chloramine sensor only) 5 - Sensor with sealed flowcell Suffix D - ph Sensor Input 1 - None 2 - Q22 ph sensor with battery preamp, 25' cable 3 - Standard ph sensor with 25' cable & adapter for overflow cell 4 - Standard ph sensor with 25' cable & sealed flowcell OPTIONS: NEMA 4X junction box Sensor interconnect cable (max. 100 ft.) Mounting bracket kit for submersible sensor Monitor pipe mounting bracket kit CO 2 buffer injection system (for precipitation control) Rotameter for CO 2 buffer system Free Chlorine Sensor polarizer (flow) Combined Chlorine Sensor polarizer (flow) Combined Chlorine Sensor polarizer (submersion) " U-bolt, 304SS Panel mount bracket kit Notes 1. All systems are supplied with one package of membranes, one 120 cc bottle of electrolyte, and one spare parts kit containing 3 each of all o-rings and special screws. 2. AC power is required to allow for two 4-20 ma outputs. 3. Flowcell for Cl 2 /ph combination systems should be kept within 25 feet of monitor. 4. Buffer packets for ph 4 & 7 supplied with PH option. 5. Pipe mount requires two 2" U-bolts ( ) 6. Panel mount requires bracket ( ). Represented By: PDS-Q45H6263 (REV-B 11/09) Analytical Technology, Inc. 6 Iron Bridge Drive Collegeville, PA Phone: 610/ Toll-Free: 800/ Fax: 610/ sales@analyticaltechnology.com Web Site: Analytical Technology Unit 1 & 2 Gatehead Business Park Delph New Road, Delph Saddleworth OL3 5DE Phone: Fax: sales@atiuk.com

5 Typical System Diagrams STANDARD SYSTEM DIAGRAM ATI-0730 SYSTEM DIAGRAM w/optional ph SENSOR ATI-0648 Page 1 of 12

6 SYSTEM DIAGRAM w/optional ph (BAYONET STYLE) PROBE MENU ESC ENTER ATI-0863 SYSTEM DIAGRAM w/sealed FLOWCELLS MENU ESC ENTER Page 2 of 12

7 Enclosure Dimensions 2-WIRE VERSION (or BATTERY POWERED) ATI-0655 NOTE: JUNCTION BOXES HAVE SAME DIMENSIONS AS 2-WIRE TRANSMITTER AC POWERED VERSION Material: Polycarbonate Ratings: Nema 4X (IP-66) V-0 Fire Retardant MENU ESC ENTER ATI-0706 WALL MOUNTING MENU ESC ENTER ATI-0709 Page 3 of 12

8 Enclosure Mounting Options PIPE MOUNTING MENU ESC ENTER NOTE: PLATE MAY BE TURNED 90 FOR VERTICAL PIPE MOUNTING ATI-0710 PANEL MOUNTING - AC UNITS ATI-0711 Page 4 of 12

9 Enclosure Mounting Options FLOW SENSOR DIMENSIONS & OVERFLOW CELL INSTALLATION (4) ¼" DIA. THRU HOLES CUSTOMER MOUNTING OVERFLOW CELL ASSEMBLY P/N: Material: Acrylic Mounting Plate: PVC 4.20" 107mm 6.40" 163mm 7.00" 178mm CONNECTOR 1) Sensor Material: Noryl EN265 & Stainless Steel Cl 2 FLOW SENSOR P/N: ) Connector is not submersible. 3) Outer diameter of sensor: 1.75" Dia. 44.5mm Dia. CLEAR ACRYLIC 1/16" THK. S.S. 2.75" 70mm ½" BARB FITTING (DRAIN) ATI " 114mm ¼" BARB FITTING (INLET) SEALED FLOWCELL ASSEMBLY DIMENSIONS Page 5 of 12

10 Sensor Dimensions and Installation SUBMERSIBLE SENSOR DIMENSIONS 25' CABLE STANDARD Cl 2 SUBMERSIBLE SENSOR P/N: " 56mm 1" NPT TEMPERATURE SENSOR 5.7" 145mm 4.9" 124mm ATI-004 SUBMERSIBLE SENSOR INSTALLATION SENSOR CABLE TO MONITOR 2" HANDRAIL SWIVEL MOUNTING BRACKET w/ HARDWARE,( ) 1" T X T PVC COUPLING (SUPPLIED WITH SWIVEL KIT) 1" ALUMINUM CONDUIT, THREADED ONE END OR 1" SCHEDULE 80 PVC PIPE. LENGTH AS REQUIRED (CUSTOMER SUPPLIED) ATI-0155 Page 6 of 12

11 Sensor Dimensions and Installation POWER, RELAY, AND OUTPUT CONNECTIONS POWER SUPPLY AS SHOWN FOR VDC OPTION RELAY WIRING TB3 DETAIL NOTE: DEVICE EXTERNAL WIRING ARE TYPICAL EXAMPLES. RELAY CONTACTS SHOWN IN NORMAL MODE. Page 7 of 12

12 Electrical Connections ELECTRICAL CONNECTIONS - 2-WIRE TRANSMITTER NOTES: 1. Voltage between Terminals 12 & 13 MUST be between 16 & 35 VDC. 2. Earth ground into Terminal 15 is HIGHLY recommended. This connection can greatly improve stability in electrically noisy environments. ATI-0658 Page 8 of 12

13 Electrical Connections SENSOR CONNECTIONS - REMOTE JUNCTION BOX ATI-0714 Page 9 of 12

14 Sensor Dimensional & Wiring OPTIONAL ph SENSOR DIMENSIONS OPTIONAL ph SENSOR (BAYONET STYLE) DIMENSIONS SPECIAL APPLICATION FLOWCELLS (CONSULT FACTORY) CONNECTOR 1) Sensor Material: Noryl EN265 & Stainless Steel 2) Connector is not submersible. 1¼" NPT Flow "T": 1) Max. 50 PSI for Flow "T" operation. 3) Outer diameter of sensor: 1.75" Dia. 44.5mm Dia. Cl 2 FLOW SENSOR P/N: " 107mm 2) Use Teflon tape to seal In-Line Sensor. Low Volume Flowcell: 1) Material: Clear Acrylic 1¼" NPT PVC FLOW ADAPTOR 1¼" NPT SCHED. 80, 1½" PVC FLOW "T" ASSEMBLY ( ) LOW VOLUME FLOWCELL ASSEMBLY ( ) (2) ¼" BARB FITTINGS 3.325" 84.5mm ATI " 122mm (2) 8-32 THREADED INSERTS 1.0" 25.4mm Page 10 of 12

15 OPTIONAL ph SENSOR CONNECTIONS ATI-0660 Page 11 of 12

16 Electrical Connections SENSOR CONNECTIONS - Cl 2 / phwith JUNCTION BOX ( ) Bayonet Style ph Probe CANNOT be used in a remote application QUANTUM ATI-0716 Page 12 of 12

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013 Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double

More information

ph/orp Sensor Model 399 ph/orp

ph/orp Sensor Model 399 ph/orp Model 399 ph/orp Product Data Sheet PDS 71-399 September 1999 ph/orp Sensor DOUBLE JUNCTION REFERENCE CELL provides longer sensor life in process solutions containing poisoning ions. ONE-PIECE CONSTRUCTION

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011 Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED

More information

NEW QUICK CABLE-TO-SENSOR RELEASE,

NEW QUICK CABLE-TO-SENSOR RELEASE, Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008 Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Technology For Solutions Data Sheet LRE/102 Supersedes LRE/400 Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Common Features Differential Electrode

More information

Figure 1: WPR2 Dimensions and Hardware

Figure 1: WPR2 Dimensions and Hardware Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer Technical Offer Antek Model 6200 Analyzer 2015.4 Determine Total Sulfur and Total Nitrogen in a single analyzer Meet sulfur regulations and control your process with continuous sulfur and/or nitrogen measurements

More information

Model DFX Doppler ultrasonic flow meter

Model DFX Doppler ultrasonic flow meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model DFX Doppler ultrasonic flow meter Features Badger

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1 DUST ALERT - 3000 BinMaster Price Book 01-2019 binmaster.com Subject to change without notice 1 DUST ALERT - 3000 Dust Alert - 3000 The Dust Alert with integrated electronics and sensing probe utilizes

More information

ELECTRICAL INSTALLATION

ELECTRICAL INSTALLATION ENCLOSURE DIMENSIONS NOTES (3) 3/4" NPT WALL MOUNT BRACKET, (2) 5/16" DIA. THRU - HARDWARE IS CUSTOMER SUPPLIED 1¼" NPT AUTO-TEST OPTION 6.312" 160.3 mm 4.85" 123 mm 3.90" 99 mm 4.95" 126 mm 4.85" 123

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006 Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Vortex Eggs Delta Flowmeter

Vortex Eggs Delta Flowmeter Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water Rev: 08/19/2013 (ATiMX) Features Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water The Auto Touch Independent Max (ATiMX)

More information

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging

More information

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Ultrasonic Flowmeters Models PT400 & PT500 Measure Flow of Clean Fluids in Full Pipes with Non-contacting Ultrasonic

More information

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) LAKEWOOD INSTRUMENTS MODEL 260 SERIES BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,

More information

Royce Total Suspended Solids Systems. Water & Wastewater

Royce Total Suspended Solids Systems. Water & Wastewater Royce Total Suspended Solids Systems Water & Wastewater Portable and Continuous TSS Systems MODEL 711 PORTABLE MLSS/ILA SYSTEM FEATURES Two complete analyzers in one package (TSS & Interface Level) Microprocessor

More information

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device 2SGT Electronic Pressure Instrument Three Separate Functions in a Single Loop-Powered Device Switch Two Independent, Programmable SPST Solid State Relays Program switch open and close values in engineering

More information

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor! PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable

More information

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MUNICIPAL AND INDUSTRIAL WATER & WASTEWATER PROCESSING NOSHOK provides pressure, level and temperature measurement solutions, along with diaphragm

More information

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS). PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water

More information

Environmental/Analytical LabCivil Engineering Lab Equipment

Environmental/Analytical LabCivil Engineering Lab Equipment DIGITAL PH METER Display : 3.5 Digit LED. Range : ph 0 to 14.00, mv 0 to ± 1999. Resolution : ph 0.01, mv 1. : ph ± 0.01, mv ± 1 mv. Temp. Compensation : Auto 0 to 100 deg. C., Manual 0 to 100 deg. C.

More information

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP DESCRIPTION The MEMFlo MFTV Metal Bodied Flow Meters with Clear Top are simple, accurate, meters for use in a wide range of industrial liquid and gas

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

Installation and Operation Instructions DLP Series

Installation and Operation Instructions DLP Series Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW

More information

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller An IDEX Water & Wastewater Business pulsafeeder.com Boiler Programmable Boiler Controller Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading

More information

Rosemount 8750WB Magnetic Flowmeter System

Rosemount 8750WB Magnetic Flowmeter System Rosemount 8750WB Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet 00813-0200-4750 Rev AA THE 8750W MAGNETIC FLOWMETER Rosemount reliability customized for Water,

More information

KEL DIFFERENTIAL PRESSURE FLOWMETERS

KEL DIFFERENTIAL PRESSURE FLOWMETERS KEL DIFFERENTIAL PRESSURE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Rugged Metal Construction Flow Rate to 2000 GPM Linear Scale For Horizontal or Vertical Pipes Threaded

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements. BASIC Data Sheet No. B-699 IN-LINE LIQUID FLOW RATE MONITORS CHOICE OF THREE MATERIALS OF CONSTRUCTION Select from aluminum, brass or stainless steel to meet system and liquid requirements. UNRESTRICTED

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-222/rev.A January 2011 Model 222 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS Wetted

More information

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

Laboratory Room Controller

Laboratory Room Controller Technical Specification Sheet Rev. 5, April, 2001 Laboratory Room Controller Description The APOGEE Automation System Laboratory Room Controller (LRC) provides Direct Control (DDC) for laboratory space

More information

PMG MAGNETIC FLOWMETER

PMG MAGNETIC FLOWMETER PMG MAGNETIC FLOWMETER Flow Pressure Level Temperature measurement monitoring control Flow Ranges 0.015-0.5 Through 350-10600 GPM 1/2 to 12 Sizes Accuracy ±0.5% or ±0.25% of Reading Viscosity and Density

More information

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Mid-West Instrument. Series 700 Wet/Wet Installation and Operating Instructions. Differential Pressure Transmitter Mid-West Instrument IM_700/A Series 700 "Wet/Wet" Installation and Operating Instructions Differential Pressure Transmitter 6500 Dobry Dr. Sterling Heights, MI USA Toll Free: 800-648-5778 Ph 586-254-6500

More information

KEL. Heavy Duty Differential Pressure Flowmeters

KEL. Heavy Duty Differential Pressure Flowmeters Heavy Duty Differential Pressure Flowmeters measuring monitoring analyzing KEL Rugged Metal Construction Flow Rates up to 2000 GPM Linear Scales For Horizontal or Vertical s Threaded or Wafer Style s Able

More information

Integrated Vector-Type Pump Drive Product Group D and W

Integrated Vector-Type Pump Drive Product Group D and W Integrated Vector-Type Pump Drive Product Group D and W Integrated Vector-Type Pump Drive seepex has released a new integrated drive for its popular lines of MD and BW progressive cavity pumps. The drive

More information

Instrument Enclosure Assemblies

Instrument Enclosure Assemblies Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s

More information

DPT TARGET TYPE FLOWMETERS

DPT TARGET TYPE FLOWMETERS DPT TARGET TYPE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control S3 Patented Target/Leaf-Spring Design Minimal Wear Components 1.5-8 to 225-500 GPM Water Line Sizes 3/8 to 3" Wide

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Instructions EM 101 Low Flow Electromagnetic Flow Meters PDF Published June 3, 2004 Instructions EM 101 Low Flow Electromagnetic Flow Meters Installation Mounting The EM 101 model has a flow meter unit and a separate control unit containing a LCD display. The

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

General Specifications

General Specifications General Specifications DO0G Sensor for Dissolved Oxygen Analyzer GS 2J05D0-0E GENERA The DO0G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works, effluent

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control Accuracy: ±% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or Stainless

More information

Technical specification

Technical specification 15. Nov. 2010 Page 1 (5) Metso Rotating Sensor part - Rotating shear force based transmitter for pulp consistency measurement in pulp and paper industry. - Sensing element selection based on pulp type

More information

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor Models 396/396P/396R Product Data Sheet PDS 71-TUpH September 1999 Retraction/Submersion/Insertion ph/orp Sensor MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology 1 which ensures steady

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Dissolved Oxygen, ph, and Conductivity

Dissolved Oxygen, ph, and Conductivity Product Data Sheet PDS 71-steam/rev.E February 2005 Steam Sterilizable Solutions Dissolved Oxygen, ph, and Conductivity STEAM STERILIZABLE AND AUTOCLAVABLE DISSOLVED OXY- GEN, ph, AND CONDUCTIVITY SENSORS:

More information

General Specifications

General Specifications General Specifications DO30G Sensor for Dissolved Oxygen Analyzer GS 2J05D03-0E GENERA The DO30G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works,

More information

SeaMetrics Flow Meters and Flow Computers

SeaMetrics Flow Meters and Flow Computers Distributed Products Fact Sheet and Flow Computers WTP-PVC body turbine flow meter WT-S Stainless steel body turbine flow meter TX115/215 Hottap insertion turbine flow meter FT420 Looppowered flow computer

More information

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011 Product Data Sheet 71-140 series/rev.b February 2011 Model 140, 141, 142 Conductivity Sensors RUGGED CONSTRUCTION withstands high temperature and pressure TWO MOUNTING CONFIGURATIONS: screw-in and retractable

More information

Analytical Instruments Two-Electrode Conductivity Sensors

Analytical Instruments Two-Electrode Conductivity Sensors Data Sheet Analytical Instruments Two-Electrode Conductivity Sensors Model TB2 Superior accuracy in low conductivity measurement ranges. Measurement ranges from 0 to 199.9 µs/cm to 0 to 19.99 ms/cm. Resolution

More information

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement Data sheet DS/ZMT/LO EN Rev. J ZMT & ZFG Superior technology and quality from the world leader in oxygen measurement Integral reference-air supply option avoids necessity for additional equipment Dual

More information

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.

More information

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6 The Auto Touch Independent Max (ATiMX) valve brings pressure independent control technology to valves up to 6 and flow rates up to 468 GPM. It is a state-of-the-art control valve combining a high quality/

More information

Compact Low Pressure Sensor

Compact Low Pressure Sensor Overview The Low Pressure Sensor is a true differential pressure transmitter that provides ±1 inches WC (±250 Pacals) in 10 field selectable ranges (see specifications). The enclosure is designed for DIN

More information

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279 Fax (951) 652-3078

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

Optidew Vision Optical Dew-Point Meter

Optidew Vision Optical Dew-Point Meter Optidew Vision Optical Dew-Point Meter Chilled Mirror Instruments A precision hygrometer, combining drift free measurement with the flexibility of a remote sensor. Ideal for laboratory and industrial measurements,

More information

DISSOLVED OXYGEN MEASUREMENT

DISSOLVED OXYGEN MEASUREMENT DISSOLVED OXYGEN MEASUREMENT ACTEON 2030 TRANSMITTER Potentiometric measurement technology Robust, watertight, easy to install, Widescreen graphic display: instant measurements, trend line, relay state,

More information

O 2 CO CO 2 NO NO 2 NO x

O 2 CO CO 2 NO NO 2 NO x continuous emissions monitoring O 2 CO CO 2 NO NO 2 NO x FGA 900 Series Combustion & Environmental Monitoring FGA Continuous Emissions & Combustion Efficiency Monitoring The FGA range of analyzers use

More information

2-ELECTRODE CONDUCTIVITY SENSORS

2-ELECTRODE CONDUCTIVITY SENSORS LAKEWOOD INSTRUMENTS MODEL 540 2-ELECTRODE CONDUCTIVITY SENSORS INSTALLATION & OPERATION MANUAL 540K.1 540K.01 Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI 53224 USA Phone (800) 228-0839

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview Product Description The MediaGauge MG-MD is a multi-functional digital pressure gauge consisting of a media isolated piezoresistive pressure sensing element, signal conditioning circuitry for temperature

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Measuring Cells for free chlorine, chlorine dioxide, ozone

Measuring Cells for free chlorine, chlorine dioxide, ozone JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Proximity Transmitters, and Seismic Vibration Transmitters

Proximity Transmitters, and Seismic Vibration Transmitters TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The

More information

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:

More information

VORTEX IN-LINE FLOW METERS

VORTEX IN-LINE FLOW METERS VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase

More information

Digital Pressure Sensor

Digital Pressure Sensor Digital Pressure Sensor SALIENT FEATURES IP 65 enclosure Hysteresis Adjustable Programmable Pressure unit Dual Digital & Voltage Outputs Wide measurement range 1~10 bar Model Number Legend 1 2 3 4 1. Series

More information

General Purpose Toroidal Conductivity Sensors

General Purpose Toroidal Conductivity Sensors Product Data Sheet PDS 71-226/228/revF January 2011 Model 226 and 228 General Purpose Toroidal Conductivity Sensors NON-CONTACTING (TOROIDAL) SENSORS resist corrosion and fouling. SENSORS ARE IDEAL for

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

Motion sensors. Milltronics MFA 4p 6/17. Overview

Motion sensors. Milltronics MFA 4p 6/17. Overview Siemens AG 2013 Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the

More information

Pressure Transmitter

Pressure Transmitter FCO318 Differential Pressure Transmitter Accuracy 0.25% of reading Ultra low pressure measurement Wide span adjustment 2-wire ma, 3-wire or 4-wire voltage output Two configurable relays and bi-colour LED

More information