Section 3 Index Furnace Tube Skin Thermocouples

Size: px
Start display at page:

Download "Section 3 Index Furnace Tube Skin Thermocouples"

Transcription

1 Section 3 Index Furnace Tube Skin Thermocouples Thermocouple Assemblies Model Page O1 Bare End Terminations 3-1 O2 Lead Wire Extension 3-2 O3 SS Flex Armor Extension 3-3 O4 CGB Over SS Flex Armor 3-4 Thermocouple Requirements/Options 3-A Head Options 3-B Dim X Heat Shield and s 3-C Heat Shield PAGE 3-I

2 Section 3 Index Furnace Tube Skin Thermocouples Options Description Page Radial Heat Shield and s 3-D Radial Heat Shield Expansion Loop Types 3-E Expansion Loop "Radial" Type Expansion Loop Type "S" Expansion Loop PAGE 3-II

3 MODEL O1 Bare End Termination Bare Wire Termination PVC Color Coded Heat Shrink Hermetic Epoxy Seal Sheath Material Weld-Pad O.D. 0.5" Junction 3" Dim A (Sensor Length) O1 B X X 1. INSULATION EXL = AccuTru Premium High Purity, Extended Life MGO = Magnesium Oxide 2. CALIBRATION K = Type K J = Type J N = Type N T = Type T E = Type E DK = Dual Type K DJ = Dual Type J DN = Dual Type N DT = Dual Type T DE = Dual Type E 3. JUNCTION U = Ungrounded G = Grounded 4. SHEATH MATERIAL 304S = 304 SS 446S = 446 SS 276C = Hastelloy C276 HASX = Hastelloy X TITN = Titanium other materials 5. SHEATH DIAMETER 188D = D = D = other diameters 6. SENSOR LENGTH (Dim A) Flat Weld Pad 10. COMPRESSION FITTINGS C1 = 1/16" NPT SS C2 = 1/8" NPT SS C4 = 1/4" NPT SS C6 = 3/8" NPT SS C8 = 1/2" NPT SS C12 = 3/4" NPT SS 9. LEAD WIRE INSULATION X = Not Applicable with Bare End Termination 8. LEAD WIRE LENGTH X = Not Applicable with Bare End Termination 7. TERMINATION B = Bare Wire 3" Stripped Leads w/ PVC Color Coded Heat Shrink 12. OPTIONS SEE PAGE 3-A FOR OTHER OPTIONS 11. WELD PAD OPTIONS 600A = Flat Alloy 600 1"x1"x1/8" 316S = Flat 316SS 1"x1"x1/8" 310S = Flat 310SS 1"x1"x1/8" C600A = Curved Alloy600 1"x1"x1/8" C316S = Curved 316SS 1"x1"x1/8" C310S = Curved 310SS 1"x1"x1/8" other sizes Curved Weld Pad (Specify Tube OD) PAGE 3-1

4 MODEL O2 Lead Wire Extension Bare Wire Termination Transition O.D. Equal to Sheath Diameter Lead Wire In Line (Smooth) SS Transition with Hermetic Epoxy Seal Weld-Pad Sheath Material O.D. 0.5" 3" Dim L (Lead Wire Length) Silver Braze Dim A (Sensor Length) Junction O2 B 1. INSULATION EXL = AccuTru Premium High Purity, Extended Life MGO = Magnesium Oxide 2. CALIBRATION K = Type K J = Type J N = Type N T = Type T E = Type E DK = Dual Type K DJ = Dual Type J DN = Dual Type N DT = Dual Type T DE = Dual Type E 3. JUNCTION U = Ungrounded G = Grounded 4. SHEATH MATERIAL 304S = 304 SS 446S = 446 SS 276C = Hastelloy C276 HASX = Hastelloy X TITN = Titanium other materials 5. SHEATH DIAMETER 188D = D = D = other diameters 6. SENSOR LENGTH (Dim A) 8. LEAD WIRE LENGTH (Dim L) 7. TERMINATION B = Bare Wire, Last.5 inches Stripped 12. OPTIONS SEE PAGE 3-A FOR OTHER OPTIONS 11. WELD PAD OPTIONS 600A = Flat Alloy 600 1"x1"x1/8" 316S = Flat 316SS 1"x1"x1/8" 310S = Flat 310SS 1"x1"x1/8" C600A = Curved Alloy600 1"x1"x1/8" C316S = Curved 316SS 1"x1"x1/8" C310S = Curved 310SS 1"x1"x1/8" Flat Weld Pad Curved Weld Pad (Specify Tube OD) 10. COMPRESSION FITTINGS C1 = 1/16" NPT SS C2 = 1/8" NPT SS C4 = 1/4" NPT SS C6 = 3/8" NPT SS C8 = 1/2" NPT SS C12 = 3/4" NPT SS 9. LEAD WIRE INSULATION T = Teflon (450 F) G = Fiberglass (900 F) K = Kapton/Kapton (450 F) BT = SS Overbraid over Teflon BG = SS Overbraid over Fiberglass TBT = Teflon Over SS Overbraid over Teflon TGT = Teflon Over SS Overbraid over Fiberglass PAGE 3-2

5 MODEL O3 SS Flex Armor Extension Bare Wire Termination Lead Wire Eyelet.375Ø SS Flex Armor SS Transition with Hermetic Epoxy Seal Weld-Pad Crimp Sheath Material O.D. 0.5" 3" 6" Standard PVC Heat Shrink Dim L (Armor Length) 1.5" Silver Braze Dim A (Sensor Length) Junction O3 B 1. INSULATION EXL = AccuTru Premium High Purity, Extended Life MGO = Magnesium Oxide 2. CALIBRATION K = Type K J = Type J N = Type N T = Type T E = Type E DK = Dual Type K DJ = Dual Type J DN = Dual Type N DT = Dual Type T DE = Dual Type E 3. JUNCTION U = Ungrounded G = Grounded 4. SHEATH MATERIAL 304S = 304 SS 446S = 446 SS 276C = Hastelloy C276 HASX = Hastelloy X TITN = Titanium other materials 5. SHEATH DIAMETER 188D = D = D = other diameters 6. SENSOR LENGTH (Dim A) 7. TERMINATION B = Bare Wire, Last.5 inches Stripped 12. OPTIONS SEE PAGE 3-A FOR OTHER OPTIONS 11. WELD PAD OPTIONS 600A = Flat Alloy 600 1"x1"x1/8" 316S = Flat 316SS 1"x1"x1/8" 310S = Flat 310SS 1"x1"x1/8" C600A = Curved Alloy600 1"x1"x1/8" C316S = Curved 316SS 1"x1"x1/8" C310S = Curved 310SS 1"x1"x1/8" 10. COMPRESSION FITTINGS C1 = 1/16" NPT SS C2 = 1/8" NPT SS C4 = 1/4" NPT SS C6 = 3/8" NPT SS C8 = 1/2" NPT SS C12 = 3/4" NPT SS 9. LEAD WIRE INSULATION AT = Teflon (450 F) inside Armor AG = Fiberglass (900 F) inside Armor AK = Kapton/Kapton (450 F) inside Armor PAT = Teflon inside Black PVC Jacketed Armor PAG = Fiberglass inside Black PVC Jacketed Armor TAT = Teflon inside White Teflon Jacketed Armor TAG = Fiberglass inside White Teflon Jacketed Armor 8. ARMOR LENGTH (Dim L) Flat Weld Pad Curved Weld Pad (Specify Tube OD) PAGE 3-3

6 MODEL 04 Cord Grip Connector Over SS Flex Armor Bare Wire Termination Lead Wire Eyelet Aluminum Cord Grip Connector w/ Neoprene Insert In Line (Smooth) SS Transition with Hermetic Epoxy Seal Weld-Pad Sheath Material O.D. 0.5" 3" 6" Standard Dim L (Armor Length) PVC Heat Shrink 1.5" Junction Silver Braze Dim A (Sensor Length) O4 B 1. INSULATION EXL = AccuTru Premium High Purity, Extended Life MGO = Magnesium Oxide 2. CALIBRATION K = Type K J = Type J N = Type N T = Type T E = Type E DK = Dual Type K DJ = Dual Type J DN = Dual Type N DT = Dual Type T DE = Dual Type E 3. JUNCTION U = Ungrounded G = Grounded 4. SHEATH MATERIAL 304S = 304 SS 446S = 446 SS 276C = Hastelloy C276 HASX = Hastelloy X TITN = Titanium other materials 5. SHEATH DIAMETER 188D = D = D = other diameters 6. SENSOR LENGTH (Dim A) 12. OPTIONS SEE PAGE 3-A FOR OTHER OPTIONS 11. WELD PAD OPTIONS 600A = Flat Alloy 600 1"x1"x1/8" 316S = Flat 316SS 1"x1"x1/8" 310S = Flat 310SS 1"x1"x1/8" C600A = Curved Alloy600 1"x1"x1/8" C316S = Curved 316SS 1"x1"x1/8" C310S = Curved 310SS 1"x1"x1/8" Flat Weld Pad Curved Weld Pad (Specify Tube OD) 10. COMPRESSION FITTINGS C1 = 1/16" NPT SS C2 = 1/8" NPT SS C4 = 1/4" NPT SS C6 = 3/8" NPT SS C8 = 1/2" NPT SS C12 = 3/4" NPT SS 9. LEAD WIRE INSULATION AT = Teflon (450 F) inside Armor AG = Fiberglass (900 F) inside Armor AK = Kapton/Kapton (450 F) inside Armor PAT = Teflon inside Black PVC Jacketed Armor PAG = Fiberglass inside Black PVC Jacketed Armor TAT = Teflon inside White Teflon Jacketed Armor TAG = Fiberglass inside White Teflon Jacketed Armor 8. ARMOR LENGTH (Dim L) 7. TERMINATION B = Bare Wire, Last.5 inches Stripped H = See Page 3-B for Head Options All Heads include a 3/4" NPT Conduit Connection, for 1/2" NPT Conduit Connection add Code 91 to field 12. PAGE 3-4

7 Section 3 Thermocouple Requirements/Options Code Options Dim "Y" "W" "W" Dim "X" "R" Minimum Bend Radius "R" (Inches) 3/8 3/8 5/8 5/8 15/16 1.5" In Line Transition "W" Dim (Inches) 1/16 1/8 3/16 1/4 3/8 Code Bend Option Specify "X" and "Y" Dimensions Figure 3-A1 Dim X Sheath Diameter (Inches) 1/16 1/8 3/16 1/4 3/8 11 NIST Calibration (Customer to Specify Points) Bend (Specify "X" and "Y", See Figure 3-A1) 13 Certified Drawing 15 Magnetic Mounts (Contact factory) TERMINATION OPTIONS Open Lugs 8 Gauge Lugs TRANSITION OPTIONS In Line Transition (Same OD as Sensor) 1/4" OD Transition to replace standard 3/8" OD Transition 5/16" OD Transition x 5/8" Long to replace standard High Temperature Epoxy (Rated to 311 F) Ultra High Temperature Epoxy (Rated to 600 F) High Temperature Cement Silver Braze Transition to Sensor to replace Crimp Note: Stanadard Epoxy Temperature Rating is 266 F LEAD WIRE OPTIONS 24 GAUGE 18 GAUGE Standard Limits of Error Wire CONNECTOR OPTIONS Braze Adaptor to replace Tube Adaptor on Connector TAGS SS Tag to replace Paper Tag Heat Shield Heat Shield (Radiation Cover) See Pages 3C and 3D Figure 3-A FITTINGS Additional Compression Fitting HEAD AND TERMINAL BLOCKS 1/2" NPT Conduit Connection 3/4" NPT Process Side Connection Bakelite Terminal Block Ground Screw on Head EXPANSION LOOPS see Page 3-E AccuTru Lance Pad (V Shape) Contact Factory for Configuration Figure 3-A3 PAGE 3-A

8 Section 3 Thermocouple Head Options All Head Connections are 1/2" NPT Instrument x 3/4" NPT Conduit Description General Purpose Screw Cover with SS Chain Supplied with ceramic terminal block. (Consult Factory for Sensor's over 1/4" OD) Aluminum Stainless Steel Part Number A1G S2G Head General Purpose NEMA 4X Screw Cover with SS Chain Supplied with ceramic terminal block. Aluminum Cast Iron Stainless Steel A3R I3R S3R General Purpose Economical Screw Cover with SS Chain Supplied with ceramic terminal block. Aluminum Poly/White, FDA Approved Nylon/Gray A4G P4G N4G General Purpose Clamp Cover Supplied with ceramic terminal block. Aluminum A8G General Purpose Heavy Duty Screw Cover with SS Chain Supplied with ceramic terminal block. Aluminum Cast Iron Cast Iron (Gasket for NEMA 4, Ground Screw) A9G I9G I9H Explosion Proof - FM/CSA Class I, Div. 1, Gr. B,C, & D, Class II, Div. 2 Gr. E,F,&G (See Note 1) Screw Cover with SS Chain Supplied with ceramic terminal block. Phenolic Blocks available. Aluminum, NEMA 4 A1P Stainless Steel, NEMA 4X S2X Large Explosion Proof Class I, Div. 1, Gr. B,C, & D, Class II, Div. 2 Gr. E,F,&G (See Note 1) No Chain Supplied with phenolic or nylon barrier terminal strip. Aluminum, NEMA 4 A6E Cast Iron Body/ Aluminum Cover, NEMA 4 I6E PAGE 3-B Note 1: In Group "B" Atmospheres, all conduit runs must have a sealing fitting(not supplied) field installed adjacent to the enclosure

9 Section 3 Dim X Heat Shield (Radiation Cover) and s Dim W DIM X Heat Shield DIM H TC Entry Entry View Side View HEAT SHIELD P/N: HS 1. SHIELD MATERIAL materials 2 THERMOCOUPLE DIAMETER 250D = 1/4" Dia. Sheath Thermocouple 375D = 3/8" Dia. Sheath Thermocouple 3. PIPE/TUBE DIAMETER (Actual Diameter In Inches xxx.xxx) 4. LENGTH DIM "X" 5. FIBER INSULATION X = None FN = Ceramic Fiber Blanket WC = s WELD CLIP P/N: WC 1. CLIP MATERIAL materials 2 THERMOCOUPLE DIAMETER 250D = 1/4" Dia. Sheath Thermocouple 375D = 3/8" Dia. Sheath Thermocouple 3. PIPE/TUBE DIAMETER (Actual Diameter In Inches xxx.xxx) 4. QTY PER THERMOCOUPLE NOTE: Contact Factory for Heat Shield Configuration Detail PAGE 3-C

10 Section 3 Radial Heat Shield (Radiation Cover) and s GROOVED ENTRY SIDE 90 HEAT SHIELD Radial Heat Shield THERMOCOUPLE SHEATH WELD PAD RADIAL HEAT SHIELD P/N: RHS 1. SHIELD MATERIAL materials 2 THERMOCOUPLE DIAMETER 250D = 1/4" Dia. Sheath Thermocouple 375D = 3/8" Dia. Sheath Thermocouple 3. PIPE/TUBE DIAMETER (Actual Diameter In Inches xxx.xxx) 4. LENGTH DIM "X" 5. FIBER INSULATION X = None FN = Ceramic Fiber Blanket WC = s WELD CLIP P/N: WC 1. CLIP MATERIAL other materials 2 THERMOCOUPLE DIAMETER 250D = 1/4" Dia. Sheath Thermocouple 375D = 3/8" Dia. Sheath Thermocouple 3. PIPE/TUBE DIAMETER (Actual Diameter In Inches xxx.xxx) 4. QTY PER THERMOCOUPLE NOTE: Contact Factory for Heat Shield Configuration Detail PAGE 3-D

11 Section 3 Expansion Loops Refractory Wall Expansion Loop Process Tube Growth Process Tube Heat Shield Note: Specify Number of Loops C L Expansion Loop Perpendicular to Pipe Type "S" Expansion Loop PAGE 3-E

AccuTru ExL Furnace Tubeskin Thermocouples

AccuTru ExL Furnace Tubeskin Thermocouples S E N S O R T E C H N O L O G I E S AccuTru ExL Furnace Tubeskin Thermocouples Dedicated to those organizations that value improved temperature measurement for critical processes S E N S O R T E C H N

More information

MGO Thermocouples. Controls. Connection Head. Connection Head. Thermowells. Junction Fittings. Connectors Connection Heads.

MGO Thermocouples. Controls. Connection Head. Connection Head. Thermowells. Junction Fittings. Connectors Connection Heads. Connection Head Type J, K, T and E Grounded Ungrounded Exposed Sheath Materials 304 Stainless Steel 316 Stainless Steel Inconel 600 Standard Aluminum Aluminum Flip Top Cast Iron/Aluminum 316 Stainless

More information

MgO ORDER CODES. 1-1 Thermocouple Types CODE

MgO ORDER CODES. 1-1 Thermocouple Types CODE MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations A Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hardpacked standard

More information

Thermocouples W A T L O W

Thermocouples W A T L O W W A T O W Watlow s mineral insulated thermocouples are fast-responding, durable, and capable of handling high temperatures. These thermocouples are manufactured with best-in-class XACTPAK, Watlow s trademark

More information

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)... Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG

More information

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product Series TCM Multipoint Thermocouple Assemblies Multipoint Thermocouples are used in a broad range of processes and installations to monitor the temperature in multiple positions or elevations. These sensors

More information

ORDER CODES CODE. Special limits of error High-Purity MgO Insulation (99.4% Pure) Use this table only if options are desired.

ORDER CODES CODE. Special limits of error High-Purity MgO Insulation (99.4% Pure) Use this table only if options are desired. MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity

More information

ORDER CODES CODE SINGLE DUPLEX TRIPLEX E EE - J JJ JJJ K KK KKK T TT - N NN -

ORDER CODES CODE SINGLE DUPLEX TRIPLEX E EE - J JJ JJJ K KK KKK T TT - N NN - MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity

More information

Cerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated.

Cerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated. MGO Thermocouples Thermo Sensors MGO thermocouple insulation materials feature Cerampak. These MGO thermocouples are recommended where the thermocouple is immersed in liquids, high moisture, corrosive

More information

Adjustable Bayonet Thermocouple

Adjustable Bayonet Thermocouple Adjustable Bayonet Thermocouple 3 16 Diameter is standard 1 2 Probe Length is standard Lead Length Termination Easily obtaining a desired probe depth, the adjustable bayonet sensor uses a tension spring

More information

Electronic Temperature Sensor

Electronic Temperature Sensor Connection Head Type RTD or Element or RTD Cast Aluminum, Polypropylene or Stainless Steel Head Weather Proof Welded or Spring Loaded TDD TMD Hot Junction: Head Process Connection Conduit Connection 100Ω

More information

Phoenix Thermal Supply

Phoenix Thermal Supply Connection Heads, Blocks, Nipples, and Springs Hinged Heads - Flip Top Hinged Heads and Blocks Nema 4 Rated Flip-Top Design for Easy Access and Closure Hinge Pins and Latches of Stainless Steel Silicone

More information

Phoenix Thermal Supply

Phoenix Thermal Supply Connection Heads, Blocks, Nipples, and Springs Hinged Heads - Flip Top Hinged Heads and Blocks Nema 4 Rated Flip-Top Design for Easy Access and Closure Hinge Pins and Latches of Stainless Steel Silicone

More information

Standard wire insulation is glass over glass with a stainless steel overwrap. Dual and single element. MgO versions available. rubber outer jacket.

Standard wire insulation is glass over glass with a stainless steel overwrap. Dual and single element. MgO versions available. rubber outer jacket. www.tcproducts.com 1-800-727-5646 Thermo-Couple Products Co. T C P engine exhaust and compressor thermocouples are available in a variety of configurations to satisfy many different requirements. The standard

More information

Seismic Sensor Accessories SA, SV & ST 6000 Series

Seismic Sensor Accessories SA, SV & ST 6000 Series Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28

More information

Thermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances

Thermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances Watlow is a world class supplier of temperature measurement products, with more than 90 years of manufacturing, research and design expertise. Companies engaged in critical process control of food and

More information

Thermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA

Thermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA Watlow is a world class supplier of temperature measurement products, with more than 90 years of manufacturing, research and design expertise. Companies engaged in critical process control of food and

More information

Hot Runner Thermocouples Model TC46

Hot Runner Thermocouples Model TC46 Electrical Temperature Measurement Hot Runner Thermocouples Model TC46 WIKA Data Sheet TE 65.46 Applications Plastics and rubber industry Hot Runner bushings, drops and nozzles Hot Runner manifolds Moulds

More information

Sensors. Table of Contents. Remote Mounted Model 1340 (A-3) Field Adjustable (A-4) General Purpose (A-24)... 4

Sensors. Table of Contents. Remote Mounted Model 1340 (A-3) Field Adjustable (A-4) General Purpose (A-24)... 4 Sensors Table of Contents page Remote Mounted Model 1340 (A-3)... 2 Field Adjustable (A-4)... 3 General Purpose (A-24)... 4 Connectors and Accessories (A-30 & 31)... 5 Multiple Sensor Assembly (A-25)...

More information

( )

( ) (1-800-492-8826) OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels

More information

(770)

(770) (770) 345-0010 OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels

More information

Thermocouples W A T L O W

Thermocouples W A T L O W W A T L O W Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions of thermocouples for

More information

ELECTRICAL INSTALLATION

ELECTRICAL INSTALLATION ENCLOSURE DIMENSIONS NOTES (3) 3/4" NPT WALL MOUNT BRACKET, (2) 5/16" DIA. THRU - HARDWARE IS CUSTOMER SUPPLIED 1¼" NPT AUTO-TEST OPTION 6.312" 160.3 mm 4.85" 123 mm 3.90" 99 mm 4.95" 126 mm 4.85" 123

More information

CATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories

CATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories CATENARY ACCESSORIES INSTRUCTIONS Quick Connect Jumper Cord AY-QC7P6-X Sheet 2 Quick Connectors AY-QC7SET Sheet 3 3/32" Stainless Steel Cable AY-CBL3/32-50 Power Cord AY-P6-50 Power Cord Ties AY-WT-100

More information

AccuTru Thermowells. Dedicated to those organizations that value improved temperature measurement for critical processes

AccuTru Thermowells. Dedicated to those organizations that value improved temperature measurement for critical processes S E N S O R T E C H N O L O G I E S AccuTru Thermowells Dedicated to those organizations that value improved temperature measurement for critical processes Section 5 Index Thermowells Model Page PT-1

More information

C 6" TYPICAL 5/8" ORDER CODES JP3 3 U. Options

C 6 TYPICAL 5/8 ORDER CODES JP3 3 U. Options onfiguration ode PL01 GeneralPurpose Tube and Wire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications

More information

Plastic. General Purpose Tube and Wire Thermocouples ORDER CODES. Example Order Number:

Plastic. General Purpose Tube and Wire Thermocouples ORDER CODES. Example Order Number: General Purpose Tube and Wire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications where a 1/8" NPT

More information

RAPID SHIP SENSORS, STOCK WIRE

RAPID SHIP SENSORS, STOCK WIRE W A T L O W RAPID SHIP SENSORS, STOCK WIRE AND CONNECTORS ISO 900 : 2000 Registered Company Richmond, Illinois USA 2005 New Rapid Ship Program Responds to Your Immediate Sensing Needs Capabilities Watlow

More information

General Specifications

General Specifications General Specifications Model RS and RN Resistance Temperature Sensor GS 06B04D01-00E GENERAL Model RS and RN Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in

More information

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS F M. Flow sensor MAG 1100 F 3/59 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

RTI-4. Flexible Sensor Temperature Assemblies. Features Multiple mounting possibilities. Anywhere a temperature measurement is needed.

RTI-4. Flexible Sensor Temperature Assemblies. Features Multiple mounting possibilities. Anywhere a temperature measurement is needed. November 2015 The Versatile WORM mounts anywhere a temperature measurement is needed. Featuring Moore Industries innovative WORM Flexible Sensor, these versatile temperature assemblies mount directly to

More information

Temperature Sensors. Request Quote

Temperature Sensors. Request Quote see more at SORInc.com Request Quote Temperature s SOR manufactures a complete line of thermocouple elements, Resistance Temperature Detector (RTD) sensors, thermowells, industrial assemblies and specialty

More information

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications Class I, Division per NEC 50.0(B)() Applications Larger body size facilitates pulling of large and heavy conductors. Specially designed raised cast covers provide additional wiring area. Mogul Unilets

More information

Cartridge Heaters W A T L O W FIREROD. Cartridge Heaters

Cartridge Heaters W A T L O W FIREROD. Cartridge Heaters W A T L O W The Watlow revolutionized the heating element industry in 94 when it was patented as the first swaged cartridge heater. With premium materials and tight manufacturing controls, the heater continues

More information

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance Specifications MagMaster MFE Series Electromagnetic Sensors nn Unrivalled flow performance ±0.2% accuracy. nn Pulsed DC Technology Incorporates Benefits of AC Systems nn Operable flow range of 1000:1.

More information

Hot runner thermocouple Model TC46

Hot runner thermocouple Model TC46 Electrical temperature measurement Hot runner thermocouple Model TC46 WIKA data sheet TE 65.46 for further approvals see page 7 Applications Plastics and rubber industry Hot runner bushings, drops and

More information

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.

More information

DIN Rail Mounting Bracket

DIN Rail Mounting Bracket DIN Rail Mounting Bracket Fits Simpson Hawk 3, Falcon and Counters Fits Standard Din Rail C 1 4.30 2.55 3.85 Din Rail Adapter 44 Enclosure: Attachment Clips: Stiffeners: Installed depth: UL94V-0 Rated

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement

More information

Tubeskin thermocouple assembly Model TC59-W

Tubeskin thermocouple assembly Model TC59-W Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-W WIKA data sheet TE 65.58 further approvals see page 7 WELD-PAD Applications Chemical industry Power generation Refineries

More information

NUMBER SIDE VIEW DESCRIPTION RANGE DIAMETER C F in. pf/ft. Coaxial, low noise, orange, PVC jacket

NUMBER SIDE VIEW DESCRIPTION RANGE DIAMETER C F in. pf/ft. Coaxial, low noise, orange, PVC jacket NUMBER SIDE VIEW DESCRIPTION RANGE DIAMETER C F in. pf/ft. J1 Coaxial, low noise, orange, PVC CABLES 55 to 80 67 to 176 0.088 cables & connectors J3 Coaxial, low noise, high temperature, red, Teflon 100

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

Cable Festoon Systems - For Moving Machinery

Cable Festoon Systems - For Moving Machinery Cable Festoon Systems - For Moving Machinery CONDUCTIX offers a comprehensive range of Cable Festoon Systems to power moving machinery. Our festoon systems are ideal for supporting, protecting, and managing

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches Form 281 The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo

More information

Maximum Temperature Rating 200 C ORDER CODES CODE DESCRIPTION. 4 Head Terminations CODE DESCRIPTION 8HN63 9HP63

Maximum Temperature Rating 200 C ORDER CODES CODE DESCRIPTION. 4 Head Terminations CODE DESCRIPTION 8HN63 9HP63 Configuration Code SP01 FEP-Coated Thermocouple Assemblies Configuration Code SP02 FEP-Coated RTD Assemblies The assemblies listed below are designed for a broad range of applications that require resistance

More information

Plastic B26650 ORDER CODES. Configuration Code PL01 General-Purpose Tube and Wire Thermocouples TOLERANCES TOLERANCES. Example Order Number:

Plastic B26650 ORDER CODES. Configuration Code PL01 General-Purpose Tube and Wire Thermocouples TOLERANCES TOLERANCES. Example Order Number: onfiguration ode P01 GeneralPurpose Tube and ire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications

More information

HEATERS AND THERMOCOUPLES

HEATERS AND THERMOCOUPLES HEATERS AND THERMOCOUPLES THERMOCOUPLES & RTD SENSORS MARATHON HEATER 808 Hackberry Lane HCR 3, Box 86E Del Rio, TX 78840 (830) 775-1417 Fax (830) 775-4379 www.marathonheater.com Marathon Heater is pleased

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

Rosemount 214C Temperature Sensors

Rosemount 214C Temperature Sensors Product Data Sheet March 2018 00813-0500-2654, Rev DB Rosemount 214C Temperature Sensors Primary product benefits High accuracy resistance temperature detectors (RTD) and various thermocouple types offered

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Field IT Electro-Magnetic Flowmeters Sensors

Field IT Electro-Magnetic Flowmeters Sensors Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.

More information

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB Electrical temperature measurement For the plastics machinery industry Adjustable bayonet Model TC47-AB WIKA data sheet TE 67.20 Applications Plastics and rubber industry For direct installation into the

More information

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS The VRF II Series uses radio frequency to detect the presence or absence of material in a vessel. It compensates for the load of the probe

More information

Cable Festoon Systems - For Moving Machinery

Cable Festoon Systems - For Moving Machinery Cable Festoon Systems - For Moving Machinery CONDUCTIX offers a comprehensive range of Cable Festoon Systems to power moving machinery. Our festoon systems are ideal for supporting, protecting, and managing

More information

Milroyal C. PD 3661 Effective 6/2009. MilRoyal C

Milroyal C. PD 3661 Effective 6/2009. MilRoyal C Milroyal C Milroyal C Pumps Milroyal C DUPLEX with HPD Liquid End GENERAL SPECIFICATIONS Drive Polar crank design all moving parts sub merged in oil. Front end scavenging The plunger always set to top

More information

Heating Cable. Construction

Heating Cable. Construction MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)

More information

FT- Thermocouples FireTECH series. FireTECH Series Thermocouples and accessories 73- Basic technical parameters

FT- Thermocouples FireTECH series. FireTECH Series Thermocouples and accessories 73- Basic technical parameters 73- FireTECH Series Thermocouples and accessories The FireTech temperature sensors are designed to measure the temperature of the air or hot surfaces in fire test chambers. The FireTECH system includes:

More information

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Electro-Magnetic Flowmeters Sensors MagMaster MFE Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year

More information

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Founded in 1941 The World s Largest Manufacturer and Supplier of Piping Components for the Pneumatic Conveying Industry.

Founded in 1941 The World s Largest Manufacturer and Supplier of Piping Components for the Pneumatic Conveying Industry. Founded in 1941 The World s Largest Manufacturer and Supplier of Piping Components for the Pneumatic Conveying Industry. COUPLING PRODUCTS Compression Couplings Side-Band Couplings Quickon II Couplers

More information

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

Band Heaters Maxiband Heaters Maxiband The Most Sought After Band Heater

Band Heaters Maxiband Heaters Maxiband The Most Sought After Band Heater Band Heaters Maxiband Heaters Maxiband The Most Sought After Band Heater A B C D E F General purpose terminal box offers excellent protection to the exposed terminals. To simplify electrical wiring, the

More information

Accessories. magnaloy coupling company P.O. Box 455 Alpena, MI INDEX: Filler Breather Adapters...3

Accessories. magnaloy coupling company P.O. Box 455 Alpena, MI INDEX: Filler Breather Adapters...3 Accessories INDEX: Magnaloy General Information... What You Should Know About Filler Breathers... Filler Breather Adapters... Filler Breathers...4 Filler Breather Cap Types...4 Mounting Flanges...4 Screen

More information

Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19

Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19 Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19 A wide variety of thermocouples commonly used in the plastics industry, suitable for high and low temperatures applications. Available in a choice

More information

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS The original TOMMY GATE hydraulic lift Assembling the Auxiliary Battery Box 1. Remove the cover from the auxiliary battery box by removing the two nuts and

More information

Cable Connectors & Conduit Sealing Bushings

Cable Connectors & Conduit Sealing Bushings RA1 Cable Terminators General Information Purpose: Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Where Installed: Wherever the

More information

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features. Model 1A 1C 1G 1Z 1P 1H Inc. Series 1 Series 1 Pressure Switch High, Low, Differential & Vacuum Pressure Switch options available All Anodized Aluminum Construction Multiple s Available UL & cul Approved

More information

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A 24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A Part #: EXP-IP-POE-INJ-24V-24W Page: 1 The EXP-IP-POE-INJ-24V-24W from Larson Electronics is an Explosion

More information

NTC Thermistor Assemblies

NTC Thermistor Assemblies FEATURES Standard and custom assemblies are available in a variety of configurations Assemblies can conveniently attach to or be an integral part of any system to monitor or control temperature No added

More information

For the plastics machinery industry Manifold thermocouple Model TC47-MT

For the plastics machinery industry Manifold thermocouple Model TC47-MT Electrical temperature measurement For the plastics machinery industry Manifold Model TC47-MT WIKA data sheet TE 67.21 Applications Plastics and rubber industry Hot runner manifolds for injection mould

More information

MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS

MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS W W W. M A R C H P U M P. C O M MARCH PUMPS Why a magnetic drive pump? A magnetic drive pump is sealless, preventing any leakage that is normally associated

More information

Flow Measurement. SITRANS F US Clamp-on. Accessories/Spare parts. 4/354 Siemens FI Accessories/Spare parts for clamp-on ultrasonic flowmeters

Flow Measurement. SITRANS F US Clamp-on. Accessories/Spare parts. 4/354 Siemens FI Accessories/Spare parts for clamp-on ultrasonic flowmeters Flow Measurement Siemens AG 2010 for clamp-on ultrasonic flowmeters Universal Portable Sensors Selected generally for portable systems where a wide variety of pipes are to be measured. Since they are selected

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on for clamp-on ultrasonic flowmeters Description Description Universal Portable Sensors Selected generally for portable systems where a wide variety of pipes are to be measured. Since they are selected based

More information

Basins, Floats & Accessories

Basins, Floats & Accessories Basins, Floats & Accessories Aqua Pro Pump Systems a Tomiko Inc. Company APPS Basins, Floats & Accessories BasinS Basin Size Gallons Weight 24 X 48 94 55 24 X 60 118 63 24 X 72 141 70 24 X 84 165 88 30

More information

Valve Position Monitors

Valve Position Monitors Valve Position Monitors EX Series for Hazardous Locations APL Series NEMA 4, 4X 1 LIMIT SWITCHES Triac APL Series Limit Switches The Triac APL Series Limit Switches feature high quality, easy to use multiple

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1). R AMG-BC-III AutoMatrix Power Connection Kit Description The AMG-BC-III is a copper free aluminum (maximum 4/10 of 1% copper) NEMA 4X (1) rated power connection kit for single or dual heating cable entry.

More information

COMPRESSION COUPLINGS Exclusive Design Features Outer Shell and Bar Washer The unique design provides an equalized pressure seal.

COMPRESSION COUPLINGS Exclusive Design Features Outer Shell and Bar Washer The unique design provides an equalized pressure seal. 1-800--1 The only economical couplings available to connect (or repair) threaded or unthreaded pipe or tubing of any size f rom 1/ thru including metric sizes and a rare oneof-a-kind size tubing. COMPRESSION

More information

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight 380 South Street 7596-763, TX Nacogdoches Phone: 936-569-79 Fax: 936-560-685 BUB00M -In Mog Cond Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial

More information

DIAL SIZE Select a dial size that allows you to comfortably read the dial from the normal distance when installed.

DIAL SIZE Select a dial size that allows you to comfortably read the dial from the normal distance when installed. 53 RANGE The maximum operating pressure should not exceed 75% of the full-scale range. The normal operating range should be in the middle half of the range (between 25% and 75% of the fullscale range);

More information

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG COMPANY OVERVIEW Since 1970, we have been pioneering new developments in heater technology and providing

More information

300 SERIES STANDARD DUTY CURVED TRACK

300 SERIES STANDARD DUTY CURVED TRACK 300 SERIES STANDARD DUTY CURVED TRACK COMPLETE TRACK MODEL NUMBERS 301A 301W 316A 316W 328A 328W 300B SERIES BLACK CURVED TRACK COMPLETE TRACK MODEL NUMBERS 301AB 301WB 316AB 316WB 328AB 328WB SINGLE CARRIER

More information

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips Tough and dependable, Woodhead cable grips and cord grip bodies are reliable workhorses in any plant environment. They serve as flexible holding devices used to pull cable, rope, or tubing into place,

More information

P627 High Flow Gas Regulator

P627 High Flow Gas Regulator P627 High Flow Gas Regulator Wide of Flow Capacities Durable Powder Coated Exterior Installation Versatility NACE Construction Available The P627 is a spring loaded, direct-operated regulator for both

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo Control:

More information

2" ROTARY VALVE 8-WAY ACTUATOR RSV SERIES. Valve body not included. Electronic Control Type:

2 ROTARY VALVE 8-WAY ACTUATOR RSV SERIES. Valve body not included. Electronic Control Type: 2" ROTARY VALVE 8-WAY ACTUATOR RSV SERIES Specification Data Electrical Requirements Gear Motor Nozzle Rotation Nozzle Seal Connection Enclosure Nozzle Total Weight: (Actuator & Nozzle) Valve body not

More information

N I S T traceable calibration equipment conforms to MIL-STD-45662A.

N I S T traceable calibration equipment conforms to MIL-STD-45662A. www.tcproducts.com 1-800-727-5646 Thermo-Couple Products Co. Turbine RTD's are used for bearing temperature measurement which provides safe and accurate monitoring. The RTD designs offer a resistance value

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

SKINNER Intrinsically Safe Series Four-Way

SKINNER Intrinsically Safe Series Four-Way SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: Moore Industries - International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A. Electrical Apparatus: Flameproof Transmitter Enclosure Models LH2XSA and BHabcA Type of

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices

More information

Armoured / Un-armoured Cable Gland

Armoured / Un-armoured Cable Gland Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance

More information