General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
|
|
- Kelly Allen
- 5 years ago
- Views:
Transcription
1 Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG with transition fitting). Standard Connector RTD s (RK, RL, or RM).. Miniature Connector RTD s (RQ, RR, or RS) Flip-Top Connection Head RTD s (RT, RV, or R4)..... Screw-Cover Connection Head RTD s (R1, R2, R5, R8, or RW)... Miniature Connection Head Thermocouples (RY, RX, or RZ).. Sheath Mounting Fitting. Sheath Mounting Fittings and Bend Options... R2 R6 R10 R11 R12 R13 R14 R15 R16 R17 R18 R19 R20 For other RTD products: See the Food, Dairy & Pharmaceutical Section of the Catalog for the for the following items: Sanitary Connected RTD s (CIP) Thermometer Replacement RTD s Penetration Style Sensors See the Thermowell Assemblies & Thermowells Section of the Catalog for the following items: RTD Style Thermowells RTD Replacement for Thermowells P F M-1
2 GENERAL INFORMATION, RESISTANCE TEMPERATURE DETECTORS (RTD's) SensorTec's complete line of Resistance Temperature Detectors (RTD's) offer an unparalleled combination of quality, performance and price to meet todays changing market. To meet a broad range of requirements, SensorTec has designed RTD's in three specific temperature ranges: the "L", "M", and "H" series. General specifications, features and available configurations for each series are as follows: þ LOW RANGE, "L" Series: -50 to +200 C (-58 to +392 F) The construction provides a cost effective and durable probe suitable for industrial process or laboratory applications and offers high accuracy, long term stability, superior interchangeability and resistance to shock and vibration. Element Types: Platinum 100Ω, 500Ω and 1000Ω ohms at 0 C (standard) (Nickel, Nickel-Iron and Copper available) Element 0 C: + 0.5% to % (Multiple DIN, DIN class A and B, Fractional DIN) Temperature Coef. (TCR): Alpha Ω/ C (1000Ω), Ω/ C (100Ω, 500Ω & 1000Ω), Ω/ C (100Ω) Applicable Standards: DIN/IEC and JIS C1604 Other Specifications: Consult sales concerning information on stability, repeatability, self-heating and vibration Sheath Diameters:.050" OD to 3/4" OD (Metric sizes also available) Sheath Material: 316 stainless steel standard, other materials available Excitation Current: 1mA or less recommended, 2mA maximum (Consult sales for applications utilizing more than 2mA) Insulation Resistance: At 21 C (70 F) with all external surfaces dry, the resistance between any leadwire and the sheath is 500 megohms or greater at 250 VDC. þ MEDIUM RANGE, "M" Series: -50 to +450 C (-58 to +842 F) This series utilizes the same basic construction as the "L" series, but offers the benefit of an extended temperature range. High accuracy, long term stability, superior interchangeability and resistance to shock and vibration make this series a significant addition to our line of high quality RTD's. R-2 Element Types: Platinum 100Ω, 500Ω and 1000Ω ohms at 0 C (standard) Element 0 C: + 0.5% to % (Multiple DIN, DIN class A and B, Fractional DIN) Temperature Coef. (TCR): Alpha Ω/ C (1000Ω), Ω/ C (100Ω, 500Ω & 1000Ω), Ω/ C (100Ω) Applicable Standards: DIN/IEC and JIS C1604 Other Specifications: Consult sales concerning information on stability, repeatability, self-heating and vibration Sheath Diameters: 1/8" OD to 3/4" OD (Metric sizes also available) Sheath Material: 316 stainless steel standard, other materials available Excitation Current: 1mA or less recommended, 2mA maximum (Consult sales for applications utilizing more than 2mA) Insulation Resistance: At 21 C (70 F) with all external surfaces dry, the resistance between any leadwire and the sheath is 100 megohms or greater at 250 VDC.
3 þ HIGH RANGE, "H" SERIES: -200 to +650 C (-328 to F) This construction utilizes a fully supported, strain free wire wound sensing element encapsulated in a compacted MgO insulated metal sheathed cable. This combination provides a probe suitable for extremely demanding applications. It offers superior resistance to pressure, shock and vibration. By utilizing the finest elements available, this style of probe displays long life, long term accuracy and excellent repeatability. Element Types: Platinum 100Ω at 0 C (standard) (Consult for other types) Element 0 C: % to % (DIN class A and B, Fractional DIN) Temperature Coef. (TCR): Alpha Ω/ C, /Ω C (100Ω) Applicable Standards: DIN/IEC and JIS C1604 Other Specifications: Consult sales concerning information on stability, repeatability, self-heating and vibration Sheath Diameters: 1/8" OD to 1/2" OD (Metric sizes also available) Sheath Material: 316 stainless steel standard, other materials available Excitation Current: 1mA or less recommended, 5mA maximum Insulation Resistance: At 21 C (70 F) with all external surfaces dry, the resistance between any leadwire and the sheath is 500 megohms or greater at 250 VDC. GENERAL LEADWIRE SIZES: Single Element Style RTD's Duplex Element Style RTD's Sheath Diameter Leadwire Size Sheath Diameter Leadwire Size under 1/8" 28 AWG under 1/8" N/A 1/8" to 5/32" 26 AWG 1/8" to 5/32 Consult 3/16" or larger 22 AWG 3/16" or larger 26 AWG Please contact the sales department for the exact leadwire type used on a specific sensor. ELEMENT SENSITIVITY, PLATINUM ELEMENTS Resistance at C 100Ω 100Ω 500Ω 1000Ω 1000Ω TCR (Ω/Ω/ C) Sensitivity (Avg. Ω/ C) LEADWIRE RESISTANCE TABLE AWG 25 C AWG 25 C *Based on Silver Plated Copper Conductor (Teflon insulated leads) R-3
4 LEADWIRE EFFECT Leadwire error can have a significant effect on RTD performance. Since an RTD is a resistance type sensor, introducing leadwire between the RTD and instrument will add additional resistance to readings. Also, additional resistance is not constant but increases with ambient temperature. To estimate leadwire error for a 2-wire configuration, multiply the total length of the extension leads by the resistance per foot in the table on the previous page. Then divide by the sensitivity of the RTD, given in the table on the previous page to obtain an error in C. Example: 100Ω platinum RTD with a TCR of and 50 ft. of 22 AWG leadwire. R = 50 ft. x Ω/ft. = 0.825Ω Approximate error = 0.825Ω / 0.385Ω = 2.14 C In most cases, you can cancel leadwire resistances by using a 3 or 4-wire configuration. Another way to deal with long leadwire runs is with a 2-wire current transmitter. Its linearized signal is not affected by leadwire resistance and electrical noise and is suitable for use in installations requiring several hundred feet or more of leadwire. WIRING CONFIGURATIONS AND CHARACTERISTICS (See illustration on the following page) 2-WIRE CONFIGURATION An RTD in a 2-wire configuration is the least accurate style of RTD assembly. The added lead wire resistance is not compensated for by the temperature controller or transmitter used to monitor the resistance of the RTD. This increased resistance will cause the display temperature to be higher than the actual temperature. 3-WIRE CONFIGURATION An RTD in a 3-wire configuration is the most common configuration because it is both cost effective and accurate. The added lead wire resistance is calculated by the controller through the third wire of the RTD assembly. The leadwire resistance is then subtracted from the loop resistance and true resistance is found. Through this method the controller or transmitter "compensates" the lead wire giving an accurate temperature display. SensorTec generally matches resistance between leadwires to ± 5% to ensure accurate metering. 4-WIRE CONFIGURATION An RTD in a 4-wire configuration not only cancels leadwire resistance, but removes the effects of mismatched resistances such as contact points. 4-wire circuits are recommended for high accuracy sensors and are usable over longer distances than 3-wire circuits. SPECIAL DETECTORS SensorTec has the ability to design & produce several types of specialized sensors. Nominal resistance values include: 10Ω, 25.5Ω, 50Ω, 200Ω, and 2000Ω, at 0 C. Several sheath materials and sizes are available to meet your specific requirement. Leadwire can be supplied in virtually any material. Contact our Technical Assistance Team for engineering assistance. R-4
5 SINGLE RTD CONFIGURATIONS & COLOR CODES DUPLEX RTD CONFIGURATIONS & COLOR CODES 2-Wire 2-Wire 3-Wire 3-Wire 4-Wire R-5
6 For 100 Ohm Platinum RTD Sensors (ITS-90 Revision) C C C C
7 For 100 Ohm Platinum RTD Sensors (ITS-90 Revision) C C C C
8 For 100 Ohm Platinum RTD Sensors (ITS-90 Revision) C C C C
9 For 100 Ohm Platinum RTD Sensors (ITS-90 Revision) C C C C
10 PART NUMBERING EXAMPLES FOR RTD's R SHEATH TERMINATION ELEMENT TYPE ACCURACY & TEMPERATURE COEFFICIENT TEMPERATURE RANGE SHEATH DIAMETER SHEATH MATERIAL LEADWIRE TERMINATIONS LEADWIRE LENGTH ("B") LEADWIRE TYPE SHEATH MOUNTING FITTING SHEATH LENGTH ("A" Fractional) SHEATH LENGTH ("A") RBBGL-KW06A B RTD-100Ω, 3 Wire, Class B,.00385, Low Temp, 1/4" Dia. Sheath 6" long, No Fitting and 6" of Stranded Teflon Wire with Split Tinned Leads. Refer to page R-1. RTBGL-KW04A-48 RTD-100Ω, 3 Wire, Class B,.00385, Low Temp, 1/4" Dia. Sheath 4" long with a 1/2" NPT Stainless Steel Hex Nipple Mounting Provision. Refer to page R-5. R-10
11 R A H - - (1) Sheath Termination Bulk Material, Stripped Bare Lead A (6) Sheath Material 316 SST W (2) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A (3) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B 0.12% G H Class A 0.06% J K 1/3 rd 0.04% M N Consult factory for other element accuracies. (4) Temperature Range H Series -200 C to 500 C (-328 F to 932 F ) (5) Sheath Diameter (inches) 1/8 (.125) G 1/4 (.250) K 3/16 (.188) I 3/8 (.375) N H (7 & 8) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (9) Sheath Fractional Length ( A Fractional) None A 1/4 G 5/8 N 1/16 B 3/8 J 3/4 Q 1/8 C 1/2 L 7/8 S 3/16 E (10) Strip Length 1/4 A 1/2 B 3/4 C 1 D 2 E 2-1/2 F 3 G Note: The available strip length options may be limited on small diameter & some duplex configurations due to the fragile nature of the conductors. P F R-11
12 R B - W (1) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A Platinum 1000Ω Single K L M Note: 1000Ω not available with H Series (Temp Range) (2) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B ±0.12% G H Class A ±0.06% J K 1/3 rd ±0.04% M N Consult factory for other element accuracies. (3) Temperature Range L Series -50 C to 200 C (-58 F to 392 F) M Series -50 C to 400 C (-58 F to 752 F) (4) Sheath Diameter (inches) 1/8 (.125) G 1/4 (.250) K 3/16 (.188) I 3/8 (.375) N (5) Sheath Material 316 SST W (6 & 7) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (8) Sheath Fractional Length ( A Fractional) None A 1/4 G 5/8 N 1/16 B 3/8 J 3/4 Q 1/8 C 1/2 L 7/8 S 3/16 E (9 & 10) Sheath Mounting Fitting Select fitting from pages M-19 & M-20 None 00 L M (11) Lead Wire Type Stranded Wire C F Code Fiberglass Insulated Cable 450 C 842 F D Fiberglass w/ SST Flex Armor 450 C 842 F E Fiberglass w/ SST Over Braid 450 C 842 F F Teflon Insulated Cable 200 C 392 F M Teflon Cable w/ SST Flex Armor 200 C 392 F N Teflon Cable w/ SST Over Braid 200 C 392 F O Shielded Teflon Cable 200 C 392 F P Individual Teflon Single Leads 200 C 392 F 1 Individual Fiberglass Single Leads 450 C 842 F 9 Note: For a complete list of all wire options, refer to page?? (12, 13, & 14) Lead Wire Length Inches ( B ) Whole Inches: Example: 048 = 48 inches Note: For lead wire beyond the flex armor ( C length), include length After B length. Example: 048(012) = 12 of leads beyond the flex (15) Lead Wire Termination Options None Split Leads (2-1/2 ) / Stripped Split Leads with #8 Spade Lugs Split Leads with 1/4 Push-On Terminals Split Leads with Insulated Wire Sleeves Standard Male Plug (200 C / 382 F) Standard Plug with Mating Jack Standard Female Jack Miniature Male Plug (200 C / 382 F) Miniature Plug with Mating Jack Miniature Female Jack (16) Special Options BX Electrical Connector, 1/2 NA NA F PVC Coating over Flex Armor (Black) 90 C 194 F J Teflon Coating over Flex Armor (White) 200 C 392 F K Teflon Encapsulated Sheath (Black) 200 C 392 F T *For a complete list of Special Options, refer to page?? A B C E J K L M Q R S P F R-12
13 R - W (1) Transition Style Style C F Code Standard Transition Fitting 200 C 392 F D Hi-Temp Transition Fitting 450 C 842 F E Transition w/ Relief Spring 200 C 392 F F Hi Temp w/ Relief Spring 450 C 842 F G (2) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A Platinum 1000Ω Single K L M Note: 1000Ω not available with H Series (Temp Range) (3) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B ±0.12% G H Class A ±0.06% J K 1/3 rd ±0.04% M N Consult factory for other element accuracies. (4) Temperature Range L Series -50 C to 200 C (-58 F to 392 F) M Series -50 C to 400 C (-58 F to 752 F) H Series -200 C to 500 C (-328 F to 932 F ) (5) Sheath Diameter (inches) 1/8 (.125) G 1/4 (.250) K 3/16 (.188) I 3/8 (.375) N (6) Sheath Material 316 SST W (7 & 8) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (9) Sheath Fractional Length ( A Fractional) None A 1/8 C 1/4 G 1/2 L 3/4 Q 1/16 B 3/16 E 3/8 J 5/8 N 7/8 S L M H (10 & 11) Sheath Mounting Fitting Select fitting from pages M-19 & M-20 None 00 (12) Lead Wire Type Stranded Wire C F Code Fiberglass Insulated Cable 450 C 842 F D Fiberglass w/ SST Flex Armor 450 C 842 F E Fiberglass w/ SST Over Braid 450 C 842 F F Teflon Insulated Cable 200 C 392 F M Teflon Cable w/ SST Flex Armor 200 C 392 F N Teflon Cable w/ SST Over Braid 200 C 392 F O Shielded Teflon Cable 200 C 392 F P Individual Teflon Single Leads 200 C 392 F 1 Individual Fiberglass Single Leads 450 C 842 F 9 Note: For a complete list of all wire options, refer to page?? (13, 14, & 15) Lead Wire Length Inches ( B ) Whole Inches: Example: 048 = 48 inches Note: For lead wire beyond the flex armor ( C length), include length After B length. Example: 048(012) = 12 of leads beyond the flex (16) Lead Wire Termination Options None Split Leads (2-1/2 ) / Stripped Split Leads with #8 Spade Lugs Split Leads with 1/4 Push-On Terminals Split Leads with Insulated Wire Sleeves Standard Male Plug (200 C / 382 F) Standard Plug with Mating Jack Standard Female Jack Miniature Male Plug (200 C / 382 F) Miniature Plug with Mating Jack Miniature Female Jack (17) Special Options BX Electrical Connector, 1/2 NA NA F PVC Coating over Flex Armor (Black) 90 C 194 F J Teflon Coating over Flex Armor (White) 200 C 392 F K Teflon Encapsulated Sheath (Black) 200 C 392 F T *For a complete list of Special Options, refer to page?? A B C E J K L M Q R S P F R-13
14 R - W - - (1) Sheath Termination Connector Option C F Code Standard Male Plug 200 C 392 F K Standard Plug with Mating Jack 200 C 392 F L Standard Female Jack 200 C 392 F M (2) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A Platinum 1000Ω Single K L M Note: 1000Ω not available with H Series (Temp Range) (3) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B ±0.12% G H Class A ±0.06% J K 1/3 rd ±0.04% M N Consult factory for other element accuracies. (4) Temperature Range L Series -50 C to 200 C (-58 F to 392 F) M Series -50 C to 400 C (-58 F to 752 F) H Series -200 C to 500 C (-328 F to 932 F ) L M H (6) Sheath Material 316 SST W (7 & 8) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (9) Sheath Fractional Length ( A Fractional) None A 1/4 G 5/8 N 1/16 B 3/8 J 3/4 Q 1/8 C 1/2 L 7/8 S 3/16 E (10 & 11) Sheath Mounting Fitting NPT Size 1/8 1/4 1/2 SST Compression Fitting 1A 1B 1D Brass Compression Fitting 2A 2B 2D Re-Adjustable SST Compr. Ftg. 3A 3B 3D Note: For a complete listing of sensor mounting options, compatibility, specifications, and ordering instructions, please see page M-?. (12) Special Options Compression Tube Adapter on Connector Teflon Encapsulated Sheath (Black) C T (5) Sheath Diameter (inches) 1/8 (.125) G 1/4 (.250) K 3/16 (.188) I 3/8 (.375) N P F R-14
15 R - W - - (1) Sheath Termination Connector Option C F Code Miniature Male Plug 200 C 392 F Q Miniature Plug with Mating Jack 200 C 392 F R Miniature Female Jack 200 C 392 F S (2) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A Platinum 1000Ω Single K L M Note: 1000Ω not available with H Series (Temp Range) (3) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B ±0.12% G H Class A ±0.06% J K 1/3 rd ±0.04% M N Consult factory for other element accuracies. (4) Temperature Range L Series -50 C to 200 C (-58 F to 392 F) M Series -50 C to 400 C (-58 F to 752 F) H Series -200 C to 500 C (-328 F to 932 F ) L M H (6) Sheath Material 316 SST W (7 & 8) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (9) Sheath Fractional Length ( A Fractional) None A 1/4 G 5/8 N 1/16 B 3/8 J 3/4 Q 1/8 C 1/2 L 7/8 S 3/16 E (10 & 11) Sheath Mounting Fitting NPT Size 1/8 1/4 1/2 SST Compression Fitting 1A 1B 1D Brass Compression Fitting 2A 2B 2D Re-Adjustable SST Compr. Ftg. 3A 3B 3D Note: For a complete listing of sensor mounting options, compatibility, specifications, and ordering instructions, please see page M-?. (12) Special Options Compression Tube Adapter on Connector Teflon Encapsulated Sheath 200 C / 392 F (Black) C T (5) Sheath Diameter (inches) 1/8 (.125) G 3/16 (.188) I P F R-15
16 R (1) Sheath Termination Material C F Code Cast Aluminum 200 C 392 F T White Polypropylene 90 C 194 F V Din B Size Aluminum WP 200 C 392 F 4 (2) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A Platinum 1000Ω Single K L M Note: 1000Ω not available with H Series (Temp Range) (3) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B ±0.12% G H Class A ±0.06% J K 1/3 rd ±0.04% M N Consult factory for other element accuracies. (4) Temperature Range L Series -50 C to 200 C (-58 F to 392 F) M Series -50 C to 400 C (-58 F to 752 F) H Series -200 C to 500 C (-328 F to 932 F ) (5) Sheath Diameter (inches) 1/8 (.125) G 1/4 (.250) K 3/16 (.188) I 3/8 (.375) N L M H (6) Sheath Material 316 SST W (7 & 8) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (9) Sheath Fractional Length ( A Fractional) None A 1/4 G 5/8 N 1/16 B 3/8 J 3/4 Q 1/8 C 1/2 L 7/8 S 3/16 E (10 & 11) Sheath Mounting Fitting NPT Size 1/8 1/4 1/2 SST Compression Fitting 1A 1B 1D Brass Compression Fitting 2A 2B 2D Re-Adjustable SST Compr. Ftg. 3A 3B 3D Fixed Hex Nipple, 316 SST Spring Loaded Hex Nipple SST N/A N/A 56 Note: For a complete listing of sensor mounting options, compatibility, specifications, and ordering instructions, please see page M-?. (12) Special Options Non-Isolated Transmitter, PC Programmable Q9 Isolated Transmitter, PC Programmable Q2 Grounding Stud (Screw) G Conduit Opening Reducer, 3/4 x 1/2 R Teflon Encapsulated Sheath 200 C / 392 F (Black) T See the Temperature Transmitter Section for complete transmitter options and specifications. P F R-16
17 R (1) Sheath Termination Material C F Rating Code Cast Aluminum 200 C 392 F NEMA 4 1 Cast Iron 200 C 392 F NEMA 4 2 White Polypropylene 90 C 194 F IP65 5 Stainless Steel (316) 200 C 392 F NEMA4X 8 Explosion Proof * 90 C 194 F NEMA 4 W *FM Approved Class I, DIV I, Groups A,B,C,D, T6 Class II, III, DIV I, Groups E, F, G, T6 (2) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A Platinum 1000Ω Single K L M Note: 1000Ω not available with H Series (Temp Range) (3) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B ±0.12% G H Class A ±0.06% J K 1/3 rd ±0.04% M N Consult factory for other element accuracies. (4) Temperature Range L Series -50 C to 200 C (-58 F to 392 F) M Series -50 C to 400 C (-58 F to 752 F) H Series -200 C to 500 C (-328 F to 932 F ) (5) Sheath Diameter (inches) 1/8 (.125) G 1/4 (.250) K 3/16 (.188) I 3/8 (.375) N L M H (6) Sheath Material 316 SST W (7 & 8) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (9) Sheath Fractional Length ( A Fractional) None A 1/4 G 5/8 N 1/16 B 3/8 J 3/4 Q 1/8 C 1/2 L 7/8 S 3/16 E (10 & 11) Sheath Mounting Fitting NPT Size 1/8 1/4 1/2 SST Compression Fitting 1A 1B 1D Brass Compression Fitting 2A 2B 2D Re-Adjustable SST Compr. Ftg. 3A 3B 3D Fixed Hex Nipple, 316 SST Spring Loaded Hex Nipple SST N/A N/A 56 Note: For a complete listing of sensor mounting options, compatibility, specifications, and ordering instructions, please see page M-?. (12) Special Options Non-Isolated Transmitter, PC Programmable Isolated Transmitter, PC Programmable Grounding Stud (Screw) Conduit Opening Reducer, 3/4 x 1/2 Teflon Encapsulated Sheath 200 C / 392 F (Black) See the Temperature Transmitter Section for complete transmitter options and specifications. Q9 Q2 G R T P F R-17
18 R (1) Sheath Termination Material C F Code Miniature Aluminum 200 C 392 F Y Miniature Bakelite 200 C 392 F X Plastic Open Disk 200 C 392 F Z (2) Element Type Resistance at 0 C 2 Wire 3 Wire 4 Wire Platinum 100Ω Single A B C Platinum 100Ω Dual D E N/A Platinum 1000Ω Single K L M Note: 1000Ω not available with H Series (Temp Range) (3) Accuracy & Temperature Coefficient Accuracy at 0 C Din Jis Class B ±0.12% G H Class A ±0.06% J K 1/3 rd ±0.04% M N Consult factory for other element accuracies. (4) Temperature Range L Series -50 C to 200 C (-58 F to 392 F) M Series -50 C to 400 C (-58 F to 752 F) H Series -200 C to 500 C (-328 F to 932 F ) L M H (6) Sheath Material 316 SST W (7 & 8) Sheath Length ( A ) Whole Inches: Example 06 = 6 inches (9) Sheath Fractional Length ( A Fractional) None A 1/4 G 5/8 N 1/16 B 3/8 J 3/4 Q 1/8 C 1/2 L 7/8 S 3/16 E (10 & 11) Sheath Mounting Fitting NPT Size 1/8 1/4 1/2 SST Compression Fitting 1A 1B 1D Brass Compression Fitting 2A 2B 2D Re-Adjustable SST Compr. Ftg. 3A 3B 3D Fixed Hex Nipple, 316 SST Spring Loaded Hex Nipple SST N/A N/A 56 Note: For a complete listing of sensor mounting options, compatibility, specifications, and ordering instructions, please see page M-?. (12) Special Options Grounding Stud (Screw) Teflon Encapsulated Sheath 200 C / 392 F (Black) G T (5) Sheath Diameter (inches) 1/8 (.125) G 1/4 (.250) K 3/16 (.188) I 3/8 (.375) N P F R-18
19 SHEATH MOUNTING FITTINGS Fixed Brazed or Welded Bushings Code Description NPT "L" 6A 316 Stainless Steel 1/8.80 6B 316 Stainless Steel 1/4.81 6D 316 Stainless Steel 1/ E 316 Stainless Steel 3/ A Brass 1/8.80 7B Brass 1/4.96 7D Brass 1/ Insert "U" length Ex. 6D04 = 4" "U" length COMPRESSION FITTINGS One-time Adjustable* Available Sizes and "L" Length Code Description NPT 1/16" 1/8" 3/16" 1/4" 3/8" 1A Stainless Steel 1/ N/A 1B Stainless Steel 1/ D Stainless Steel 1/2 N/A 1.66 N/A A Brass 1/ N/A 2B Brass 1/ D Brass 1/ Re-Adjustable* Available Sizes and "L" Length Code Description NPT 1/16" 1/8" 3/16" 1/4" 3/8" 3A Stainless Steel 1/ N/A N/A 3B Stainless Steel 1/4 N/A D Stainless Steel 1/2 N/A 1.66 N/A NOTE: All Re-adjustable fittings contain Teflon ferrules standard Consult Sales for Neoprene or Lava ferrules Mounting Flanges* Code Description 25 Flange w/ Brass Compression, Adjustable 26 Flange w/ss Compression, Adjustable * NOT AVAILABLE WITH TEFLON COATED SHEATH! Double Ended Hex Nipples Compatible with Code Description NPT "L" Head Order Codes 45 Steel, brazed on 1/ T, V, W, 1, 2, 3, 4, 5, 8 46 Stainless Steel (316SS) 1/ T, V, X, Y, 1 47 Stainless Steel (316SS) 1/ T, V, X, Y, 1 48 Stainless Steel (316SS) 1/ T, V, W, 1, 2, 3, 4, 5, 8 55 Steel, spring loaded 1/ T, V, 1, 2, 3, 4, 5, 8 56 Stainless Steel, spring loaded 1/ T, V, 1, 2, 3, 4, 5, 8 57 Stainless Steel, self contained 1/ T, V, W, 1, 2, 3, 4, 5, 8 spring loaded (1/4" sheath only) 60 Stainless Steel (316SS) 3/ T, V, W, 1, 2, 3, 4, 5, 8 61 Stainless Steel (316SS) T, V, W, 1, 2, 3, 4, 5, 8 R-19
20 SHEATH MOUNTING FITTTINGS and BEND OPTIONS Bayonet Fittings Code Description Available Sheath Sizes 27 Adjustable Bayonet Fitting 1/8 28 Re-Adjustable Bayonet Fitting 1/8 29* Fixed Bayonet Fitting 1/8 3/16 1/4 * Insert "U" length Ex = 4" "U" length Adjustable/ Re-Adjustable Bayonet Fitting Fixed Bayonet Fitting Weld Pads Code Description 35 Perpendicular Pad, 316 SS, 1'' x 1" 36 Horizontal Pad, 316 SS, 1" x 1" 37 Perpendicular Radius Pad*, 316 SS, 1" x 1" 38 Horizontal Radius Pad*, 316 SS, 1" x 1" *Specify Radius (Ex. 37(2)=2"R) & consult sales for availability Perpendicular Pad 1" x 1" Horizontal Pad 1" x 1" Perpendicular Radius Pad 1" x 1" Horizontal Radius Pad 1" x 1" Sheath Bends Code Description A* 90 o Bend B* 45 o Bend * Insert "U" Length Ex. A04=4" "U" Length 45 BEND (B) 90 BEND (A) R-20
Thermocouples W A T L O W
W A T O W Watlow s mineral insulated thermocouples are fast-responding, durable, and capable of handling high temperatures. These thermocouples are manufactured with best-in-class XACTPAK, Watlow s trademark
More informationMGO Thermocouples. Controls. Connection Head. Connection Head. Thermowells. Junction Fittings. Connectors Connection Heads.
Connection Head Type J, K, T and E Grounded Ungrounded Exposed Sheath Materials 304 Stainless Steel 316 Stainless Steel Inconel 600 Standard Aluminum Aluminum Flip Top Cast Iron/Aluminum 316 Stainless
More informationElectronic Temperature Sensor
Connection Head Type RTD or Element or RTD Cast Aluminum, Polypropylene or Stainless Steel Head Weather Proof Welded or Spring Loaded TDD TMD Hot Junction: Head Process Connection Conduit Connection 100Ω
More informationMgO ORDER CODES. 1-1 Thermocouple Types CODE
MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations A Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hardpacked standard
More informationAdjustable Bayonet Thermocouple
Adjustable Bayonet Thermocouple 3 16 Diameter is standard 1 2 Probe Length is standard Lead Length Termination Easily obtaining a desired probe depth, the adjustable bayonet sensor uses a tension spring
More informationSanitary RTDs and Temperature Transmitters
SENSORS FOR FOOD AND LIFE SCIENCES. Product Information - SA/CT FOOD Sanitary RTDs and Temperature Transmitters Introduction Anderson-Negele s electronic temperature sensors combine our industry proven,
More informationSensors. Table of Contents. Remote Mounted Model 1340 (A-3) Field Adjustable (A-4) General Purpose (A-24)... 4
Sensors Table of Contents page Remote Mounted Model 1340 (A-3)... 2 Field Adjustable (A-4)... 3 General Purpose (A-24)... 4 Connectors and Accessories (A-30 & 31)... 5 Multiple Sensor Assembly (A-25)...
More informationSEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399
DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is
More informationRAPID SHIP SENSORS, STOCK WIRE
W A T L O W RAPID SHIP SENSORS, STOCK WIRE AND CONNECTORS ISO 900 : 2000 Registered Company Richmond, Illinois USA 2005 New Rapid Ship Program Responds to Your Immediate Sensing Needs Capabilities Watlow
More informationORDER CODES CODE. Special limits of error High-Purity MgO Insulation (99.4% Pure) Use this table only if options are desired.
MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity
More informationSanitary RTDs and Temperature Transmitters
Sanitary RTDs and Temperature Transmitters Modular components provide maximum configuration flexibility Unique element-to-housing design eliminates exposed threads, lowers profile All stainless steel construction
More informationThermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances
Watlow is a world class supplier of temperature measurement products, with more than 90 years of manufacturing, research and design expertise. Companies engaged in critical process control of food and
More informationThermocouples W A T L O W
W A T L O W Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions of thermocouples for
More informationThermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA
Watlow is a world class supplier of temperature measurement products, with more than 90 years of manufacturing, research and design expertise. Companies engaged in critical process control of food and
More informationORDER CODES CODE SINGLE DUPLEX TRIPLEX E EE - J JJ JJJ K KK KKK T TT - N NN -
MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity
More informationSection 3 Index Furnace Tube Skin Thermocouples
Section 3 Index Furnace Tube Skin Thermocouples Thermocouple Assemblies Model Page O1 Bare End Terminations 3-1 O2 Lead Wire Extension 3-2 O3 SS Flex Armor Extension 3-3 O4 CGB Over SS Flex Armor 3-4 Thermocouple
More informationResistance Temperature Detectors (RTDs)
Website: Resistance Temperature Detectors (RTDs) Resistance Temperature Detectors (RTD's). These detectors are frequently used in the plastics industries and many others. Care must be taken to eliminate
More informationSeismic Sensor Accessories SA, SV & ST 6000 Series
Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28
More informationN I S T traceable calibration equipment conforms to MIL-STD-45662A.
www.tcproducts.com 1-800-727-5646 Thermo-Couple Products Co. Turbine RTD's are used for bearing temperature measurement which provides safe and accurate monitoring. The RTD designs offer a resistance value
More informationIndustrial Pt100 RTD's
CA 2001 Resistance Welded process connection measuring insert. Can be Type CA 2001 CA 2003 Resistance Welded process connection 1/2"BSP Head extension 50mm standard. Aluminium Replaceable 6mm Din insert.
More informationMineral-Insulated RTD Temperature Probe According to DIN EN 60751
ata Sheet 902210 Page 1/12 Mineral-Insulated RT Temperature Probe According to IN EN 60751 For temperatures from -50 (-200) to +600 C Flexible sheath cable with vibration-resistant measuring insert As
More informationC 6" TYPICAL 5/8" ORDER CODES JP3 3 U. Options
onfiguration ode PL01 GeneralPurpose Tube and Wire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications
More informationMaximum Temperature Rating 200 C ORDER CODES CODE DESCRIPTION. 4 Head Terminations CODE DESCRIPTION 8HN63 9HP63
Configuration Code SP01 FEP-Coated Thermocouple Assemblies Configuration Code SP02 FEP-Coated RTD Assemblies The assemblies listed below are designed for a broad range of applications that require resistance
More informationGeneral Specifications
General Specifications Model RS and RN Resistance Temperature Sensor GS 06B04D01-00E GENERAL Model RS and RN Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in
More informationMineral Insulated Resistance Thermometers (RTD)
Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types
More informationAccuTru ExL Furnace Tubeskin Thermocouples
S E N S O R T E C H N O L O G I E S AccuTru ExL Furnace Tubeskin Thermocouples Dedicated to those organizations that value improved temperature measurement for critical processes S E N S O R T E C H N
More informationPPT 802, Proximity Probe Transducer System
PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current
More informationTEMPERATURE SENSOR ASSEMBLIES (PROBE)
Discription: TEMPERATURE SENSORS A temperature sensor is an element that sensed the temperature changes, then translate the measured temperature into an electrical signal which then providing the data
More informationLTX RF LEVEL SENSOR. Instruction Manual
LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths
More informationCerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated.
MGO Thermocouples Thermo Sensors MGO thermocouple insulation materials feature Cerampak. These MGO thermocouples are recommended where the thermocouple is immersed in liquids, high moisture, corrosive
More informationTemperature Sensors. Request Quote
see more at SORInc.com Request Quote Temperature s SOR manufactures a complete line of thermocouple elements, Resistance Temperature Detector (RTD) sensors, thermowells, industrial assemblies and specialty
More informationHEATERS AND THERMOCOUPLES
HEATERS AND THERMOCOUPLES THERMOCOUPLES & RTD SENSORS MARATHON HEATER 808 Hackberry Lane HCR 3, Box 86E Del Rio, TX 78840 (830) 775-1417 Fax (830) 775-4379 www.marathonheater.com Marathon Heater is pleased
More informationPlastic. General Purpose Tube and Wire Thermocouples ORDER CODES. Example Order Number:
General Purpose Tube and Wire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications where a 1/8" NPT
More informationRosemount 68 Sensor and Thermowell
Rosemount 68 Sensor and Thermowell The Rosemount 78 Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments. Features include: Industry-standard
More informationTemperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product
Series TCM Multipoint Thermocouple Assemblies Multipoint Thermocouples are used in a broad range of processes and installations to monitor the temperature in multiple positions or elevations. These sensors
More informationDST600 Series Digi-Stem Thermometers
DST600 Series Digi-Stem Thermometers User Manual 04/12/12 WD1032 Rev L (05/24/16) For use with models: DST600 DST610, DST611, DST620 & DST621 DST640 DST650, DST651, DST660, DST661 Including I, R and P
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationRTD PT100 Insert With Solid Drilled Flanged Thermowell
RTD PT100 Insert With Solid Drilled Flanged Thermowell Product Data Sheet RTINTWFL 2017 rev1.00 Full temperature sensor & thermowell assemblies. Consisting of a temperature sensing element housed in a
More informationPhoenix Thermal Supply
Connection Heads, Blocks, Nipples, and Springs Hinged Heads - Flip Top Hinged Heads and Blocks Nema 4 Rated Flip-Top Design for Easy Access and Closure Hinge Pins and Latches of Stainless Steel Silicone
More informationPhoenix Thermal Supply
Connection Heads, Blocks, Nipples, and Springs Hinged Heads - Flip Top Hinged Heads and Blocks Nema 4 Rated Flip-Top Design for Easy Access and Closure Hinge Pins and Latches of Stainless Steel Silicone
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationDirect Automation Trade Price List Process Controls Sensors 1
Direct Automation Trade Price List Process Controls Sensors 1 Sensor & Input Devices Process Controls & Sensors Process/Temperature Controllers & Assessories DPM2-AT-2R-HL ProSense digital panel meter,
More informationRosemount 183 Sensor and Thermowell
Rosemount 183 Sensor and Thermowell The Rosemount 183 Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments. Features include: Industry-standard
More informationNTC Thermistor Assemblies
FEATURES Standard and custom assemblies are available in a variety of configurations Assemblies can conveniently attach to or be an integral part of any system to monitor or control temperature No added
More informationProximity Transmitters, and Seismic Vibration Transmitters
TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The
More informationPlastic B26650 ORDER CODES. Configuration Code PL01 General-Purpose Tube and Wire Thermocouples TOLERANCES TOLERANCES. Example Order Number:
onfiguration ode P01 GeneralPurpose Tube and ire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications
More informationSECTION 7: MINIATURE SENSORS
SECTION 7: MINIATURE SENSORS Embedment sensors install in bearings for over-temperature protection Small, rugged RTDs and thermocouples withstand rough handling and harsh environments Certified non-sparking
More informationRTD Elements c/w tails.
Miscellaneous RTD Elements c/w tails. Pt100-FF Pt100-FF-3-350 Pt100-FF-3-600 Pt1000-FF Pt100-FF-DX Pt100-min Pt100-min-4 Pt100-min-5 Pt100-std Pt100-std-3 Pt100-std-4 Pt100-std-5 Pt100-DX RTD Element only,
More informationDIGI-TEL THERMOMETERS
TEL-TRU MANUFACTURING COMPANY DIGI-TEL THERMOMETERS www.teltru.com ELECTRONIC DIGITAL THERMOMETERS Tel-Tru s DIGI-TEL Thermometers combine the easy, quick visual reference feature of a local indicator
More informationFoxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element
Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement
More informationCable resistance thermometer Model TR40
Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 11 Applications For direct installation into the process Machine building
More informationPush-in RTD Temperature Probe with Connecting Cable
Data Sheet 902150 Page 1/6 Push-in RTD Temperature Probe with Connecting Cable Temperature range from -50 to +400 C As single or double RTD temperature probe In 2-wire, 3-wire or 4-wire-circuit Connecting
More informationRTI-4. Flexible Sensor Temperature Assemblies. Features Multiple mounting possibilities. Anywhere a temperature measurement is needed.
November 2015 The Versatile WORM mounts anywhere a temperature measurement is needed. Featuring Moore Industries innovative WORM Flexible Sensor, these versatile temperature assemblies mount directly to
More informationUltrasonic Two-Wire Point Level Control
Ultrasonic Two-Wire Point Level Control General Instructions The Ultrasonic Point Level Control indicates liquid presence/absence within a sensor cavity. Two piezoelectric crystals face each other across
More informationAPG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features
Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX The MPX Series Magnetostrictive Level sensor provides highly accurate and repeatable level readings in a wide variety of liquid
More information... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MCX CONNECTORS
... A Vital Part of Connection World Cable Connectors PCB Connectors s Mounting Holes MCX CONNECTORS COPYRIGHT ELECTRONICS 0 MCX Series Coaxial Connectors DESCRIPTION MCX connector are developed in Europe
More informationPlatinum Temperature Sensors 1/16
Platinum Temperature Sensors 1/16 General Information In many industrial sectors and fields of research, temperature measurement is one of the most important parameters which determines product quality,
More informationRTI-2. IECEx. Ready-to-Install TDY, TDZ 3, STZ, TFZ, THZ, TPZ, RIY & TIY Temperature Transmitter & Display Assemblies
November 2015 RTI-2 Your One Stop Temp Shop for Complete Temperature Assemblies Why waste valuable time searching around for temperature assembly pieces and parts? Our ready-toinstall temperature transmitter
More informationTE-6300 Series Temperature Sensors Catalog Page
Code No. LIT-1900217 Issued February 2017 TE-6300 Series Temperature Sensors Catalog Page Description The TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature
More informationTE-6300 Series Temperature Sensors
TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued July 14, 2008 Supersedes November 13, 2006 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety
More informationGeneral Specifications
General Specifications Models RM and RH Resistance Temperature Sensor GS 06B03B01-00E GENERAL Model RM and RH Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in
More informationWhat are RTD Sensors? Why Use Them? How Do They Work?
What are RTD Sensors? Why Use Them? How Do They Work? What is an RTD? Resistance Temperature Detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature
More informationG2 Industrial Grade Meters
G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine
More informationTemperature Measurement Solutions. Dial Indicating Electronic Industrial RTDs Thermowells Accessories
Temperature Measurement Solutions Dial Indicating Electronic Industrial RTDs Thermowells Accessories At NOSHOK, we pride ourselves on being innovators in the industry by continually offering the latest
More informationIndustrial Meter Catalog
Industrial Meter Catalog SEE INSIDE FOR THESE NEW PRODUCTS: GBM Series Mini Batcher... page 66 LM50M Mechanical Lube Meter... page 52 TM Digital Pulse Meter... page 53 VERSION 6 2008 888-996-3837 www.gpi.net
More informationProduct Catalog. Our Products. DCI Dynamic Instruments Website: dcidynamic.com
1 Product Catalog Our Products We at Dynamic are proud to present out new technical catalogue detailing our extensive range of Pressure Gauges, Thermometers, diaphragm seal, transmitter and accessories.
More informationHUMIDITY / TEMPERATURE TRANSMITTER
HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY
More informationTEMPERATURE SENSORS TEMPERATURE SENSORS
TEMPERATURE SENSORS TE Connectivity is a leader in the design and manufacture of NTC thermistors, RTDs, thermocouples, thermopiles, digital output and customized sensor assemblies. Building on our long
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationINTERNATIONAL METAL ENGINEERING
INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE
More informationSpring-Loaded RTD/Thermowell Assemblies with Connection Heads (GP03, XP03, XP05)
Operating Instructions (GP03, XP03, XP05) Beyond Measure Speed, Service, Solutions PYROMATION P/N: -006-SL-8HN31 IOIGP03 07/14 Choosing the right temperature sensor for each application is critical, but
More informationTX 115/215 Hot-tap Insertion Turbine Instructions
TX 115/215 Hot-tap Insertion Turbine Instructions General Information These hot tap versions of the proven TX insertion flow sensors are designed to install or be serviced without depressurizing the pipe.
More informationSpring-Loaded MgO Thermocouple/ Thermowell Assemblies with Connection Heads (GP04, XP04, XP06)
Operating Instructions Connection Heads (GP04, XP04, XP06) Beyond Measure Speed, Service, Solutions PYROMATION P/N: -006-SL-8HN31 IOIGP04 08/14 Choosing the right temperature sensor for each application
More informationMiniature resistance thermometer For sanitary applications Model TR21-A, with flange connection
Electrical temperature measurement Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection WIKA data sheet TE 60.26 Applications Sanitary applications Food and beverage
More informationTemperature Switch Gauges
Temperature Switch Gauges I MODEL DESCRIPTION MOUNTING TSG60B Bracket Mount (Standard) Surface TSG60K Back Flange Surface TSG60S Front Flange Panel TSG60X Explosion Proof (3 Switch Max.) Surface WINDOW
More informationSurface thermocouple Model TC50
Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial
More informationTE-6300 Series Temperature Sensors
TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued April 7, 2010 Supersedes March 13, 2009 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety
More informationUltrasonic Non Contact Sensors
3 Measuring Principle - An ultrasonic pulse is transmitted from the ABM sensor. The pulse 25-148 KHz travels to the surface being monitored and is reflected off this surface back to the sensor face. The
More informationVRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS
VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS The VRF II Series uses radio frequency to detect the presence or absence of material in a vessel. It compensates for the load of the probe
More informationStandard wire insulation is glass over glass with a stainless steel overwrap. Dual and single element. MgO versions available. rubber outer jacket.
www.tcproducts.com 1-800-727-5646 Thermo-Couple Products Co. T C P engine exhaust and compressor thermocouples are available in a variety of configurations to satisfy many different requirements. The standard
More informationResistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces
Electrical Temperature Measurement Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces WIKA Data Sheet TE 60.35 Application To measure surface temperatures on flat surfaces
More informationFax or to SENTRAN Applications Engineering Group: (909) or
WorkSheet LOAD PINS Fax or email to SENTRAN Applications Engineering Group: (909) 605-6305 or mail@sentranllc.com CONTACT: PHONE: COMPANY: FAX: ADDRESS: EMAIL: CITY: STATE: ZIP: tice! To whom it may concern:
More informationFor the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB
Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process
More informationTX101/201 Insertion Turbine Instructions
TX101/201 Insertion Turbine Instructions General Information Sapphire bearings and a non-drag pick-off give these adjustable insertion turbine flow sensors a wide flow and long life. A Hall-effect device
More informationOperating Instructions TF04
10 Brent Drive Hudson, MA 01749 Tel: +1-978-212-0006 Fax: +1-978-568-0060 Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating Instructions TF04 Temperature
More informationTemperature Sensors. NTC Thermistors. Descriptions. RTS-Raw 10K NTC Thermistor. Specifications: Dimensions (mm):
NTC Thermistors Descriptions In many industrial sectors and fields of research, temperature is one of the most important parameters which decides about product quality, security, and reliability. Temperature
More informationRosemount Pipe Clamp RTD Sensor
Product Data Sheet Platinum RTD Temperature Sensors with silver or nickel tip Non intrusive design for measurement on pipe applications Temperature-sensor matching provides increased measurement accuracy
More informationFeatures/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS
Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed
More informationBarbara, Here is the list of items. I numbered the attachments to match with the numbers below.
From: Dan Wilson [mailto: DWilson@wilsonengineerinciservices.com] Sent: Thursday, April 09, 2015 5:10 PM To: Bernstein, Barbara Subject: RE: checking... Barbara, Here is the list of items. I numbered the
More information1' to 10' deep and 1' to 25' deep
ULTRASONIC ECHO-SCALE TM SCALE: INDICATOR: ECHO-SCALE TM NONE PROVIDED electronic sensors for vessels 1' to 10' deep and 1' to 25' deep INSTALLATION & OPERATION s/n 1-800-893-6723 Fax: 925-686-6713 www.forceflow.com
More informationThermocouple & RTD Accessories (Thermowells, Connectors & Fittings)
Thermocouple & RTD ccessories (Thermowells, onnectors & Fittings) TLE OF ONTENTS ESSORIES FOR THERMOOUPLE & RTD s MODEL DESRIPTION PGE P SERIES THERMOWELLS 96 X1 THERMOOUPLE EXTENSION LES 97 X2 RTD EXTENSION
More informationHeating Cable. Construction
MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)
More informationDirect immersion resistance thermometer
Direct immersion resistance thermometer PLAIN STEM D100-101-102-103-160-162 CONFIGURATIONS General use RTD Product series PT100WT D100 D101 D102 D103 D160 D162 2 Features assembly The sensor can be immersed
More informationRosemount 214C Temperature Sensors
Product Data Sheet March 2018 00813-0500-2654, Rev DB Rosemount 214C Temperature Sensors Primary product benefits High accuracy resistance temperature detectors (RTD) and various thermocouple types offered
More informationCable resistance thermometer Model TR40
Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building
More informationSpring loaded resistance thermometer
Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial
More informationHot runner thermocouple Model TC46
Electrical temperature measurement Hot runner thermocouple Model TC46 WIKA data sheet TE 65.46 for further approvals see page 7 Applications Plastics and rubber industry Hot runner bushings, drops and
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information