C 6" TYPICAL 5/8" ORDER CODES JP3 3 U. Options
|
|
- Johnathan Morton
- 6 years ago
- Views:
Transcription
1 onfiguration ode PL01 GeneralPurpose Tube and Wire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications where a 1/8" NPT fitting is preferred by utilizing either a compression fitting or a bayonet adapter. These sensors are constructed using a 16 stainless steel sheath and insulated thermocouple wire. 5/8" 1 /" 6" TYPIL 5/8" 1 /" 1 5/8" ORDER S JP U 0 1 F101 5, X 11 Thermocouple Type SHETH O.D. SINGLE DUPLEX JP 1/8 JP JJP /16 JP JJP 1/ For type E, K or T thermocouples, replace J in order code with required letter designation. 1 end ngle 1 Straight 5 degree bend 90 degree bend 1 Junction Grounded junctions supplied as standard. Insert "U" only when requiring an ungrounded junction. "" Dimension Insert digit "" length in inches (1" min). EX: 0 = inch "" dimension. Sheath Fittings NOMINL LENGTH 00 No fitting 1 [1] 7/16" I.D. single slot springloaded 1 5/8 bayonet fitting 15 1/8" NPT brass one time adjustable comp. fitting 1 1/8 01 1/8" NPT SS one time adjustable comp. fitting 1 1/ 16 omp. fitting with bayonet cap and spring 1/8" O.D. sheaths only ( 5/8" min. '' dimension) /8 [1] 1 are not available with 1/" O.D. sheaths Extension Leadwire Type and ""+"" Dimension [1] 000 No leadwire, connector attached to sheath F1 _ Fiberglass insulation solid conductor F1 _ Fiberglass insulation solid conductor flexible armor F1 _ Fiberglass insulation solid conductor stainless steel overbraid F _ Fiberglass insulation stranded conductor F _ Fiberglass insulation stranded conductor flexible armor F _ Fiberglass insulation stranded conductor stainless steel overbraid T1 _ Fluoropolymer insulation solid conductor T1 _ Fluoropolymer insulation solid conductor flexible armor T _ Fluoropolymer insulation stranded conductor T _ Fluoropolymer insulation stranded conductor flexible armor [1] Insert digit "" length in inches. EX: F106=6" "" length; for assemblies requiring other than the standard 6" "" dimension, insert digit "" length in inches after "" dimension. EX: F10601=6" " " length with additional 1" leads beyond armor. 5 Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnect lugs X ox connector 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL1
2 onfiguration ode PL0 GeneralPurpose Plastic Industry RTDs The RTDs described below are those most commonly used in the plastic process industry. These assemblies can be used in many general applications where a 1/8" NPT fitting is preferred by utilizing either a compression fitting or a bayonet adapter. These assemblies are supplied standard using 16 stainless steel sheath material and a 100 platinum element with a temperature coefficient of º 1 (IE lass ). Elements of other materials, values, and tolerances are available upon request. 1 /" 6" TYPIL 1 /" 5/8" 5/8" 1 5/8" ORDER S RF185P 06 1 F01 5, X 11 RTD Element ELEMENT SINGLE DUPLEX [1] ONNETION RF185P RF85P wire RF185P RF85P wire [1] Duplex: no 1/8" O.D.; /16" O.D. limited to polyimide or fluoropolymer leadwire. 1 Sheath Diameter [1] 1/8 /16 1/ [1] Only available with polyimide or fluoropolymer leads. 1 end ngle 1 Straight 5 degree bend Extension Leadwire Type and ""+"" Dimension [1] 000 No leadwire, connector attached to sheath F _ Fiberglass insulation stranded conductor F _ Fiberglass insulation stranded conductor flexible armor Fiberglass insulation stranded conductor stainless F _ steel overbraid Fiberglass insulation individual leads stranded FJ _ conductor (1" limit) T _ Fluoropolymer insulation stranded conductor Fluoropolymer insulation stranded conductor flexible T _ armor K _ Polyimide insulation stranded conductor K _ Polyimide insulation stranded conductor flexible armor Polyimide insulation stranded conductor stainless steel K _ overbraid [1] Insert digit "" length in inches. EX: F106=6" "" length; for assemblies requiring other than the standard 6" "" dimension, insert digit "" length in inches after "" dimension. EX: F10601=6" "" length with additional 1" leads beyond armor. 90 degree bend 5 Terminations and "" Dimension Insert digit "" length in inches (1" min). EX: 06 = 6 inch "" dimension. Sheath Fittings NOMINL LENGTH 00 No fitting 1 [1] 7/16" I.D. single slot spring loaded bayonet ftg 1 5/8 15 1/8" NPT brass one time adjustable comp. ftg 1 1/8 01 1/8" NPT SS one time adjustable comp. fitting 1 1/ omp. fitting with bayonet cap and spring 1/8" 16 O.D. sheaths only ( 5/8" min. '' dimension) [1] 1 are not available with 1/" O.D. sheaths /8 " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnect lugs X ox connector 006 Pyromation, Inc. PL Distributed y: M&M ontrol Service, Inc
3 onfiguration ode PL0 Springdjustable Immersion Thermocouples The J series springadjustable immersion thermocouple has a bayonet cap on an 8" spring (standard) to allow for immersion depths of 1/" to 7". This assembly is used in a variety of applications (with a bayonet adapter) where ease of installation and quick disconnect is preferred. Standard and metric size bayonet caps and adapters are available. 1/" 8" STNDRD 1" MINIMUM D Q ORDER S J U F0, LS 11 Thermocouple Type SINGLE DUPLEX [1] J JJ J 1 ayonet ap Style E 1 Junction 7/16" I.D. single slot (standard) (not available with Opt. tip) 1 mm I.D. dual slot 1 mm O.D. dual pin 15 mm I.D. dual slot 1 Tip and Spring Diameters TIP O.D. 'D' DIM TYPE For type K or T thermocouples, replace J in order code with required letter designation. [1] Duplex not available with 1/8" O.D. tip. SPRING O.D. 'Q' DIM. Grounded junctions supplied as standard. Insert "U" only when requiring an ungrounded junction. Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnects X LS ox connector 1" long spring (/16" O.D. only) Extension Leadwire "" [1] Fiberglass insulation stranded F _ conductor stainless steel overbraid [1] Insert digit "" length in inches. EX: F0=" "" length. 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL
4 onfiguration ode PL0 Springdjustable Immersion RTDs This RTD springadjustable immersion sensor has a bayonet cap on an 8" spring (standard) to allow for immersion depths of 1/" to 7". This assembly is used in a variety of applications (with a bayonet adapter) where ease of installation and quick disconnect is preferred. Standard and metric size bayonet caps and adapters are available. with a temperature coefficient of º 1 (IE lass ). Elements of other materials, values, and tolerances are available upon request. 1/" 8" STNDRD 1" MINIMUM D Q ORDER S RF185 F0 11 RTD Element Type SINGLE DUPLEX [1] ELEMENT ONNETION RF185 RF85 wire RF185 RF85 wire [1] Duplex assemblies available, with polyimide wire only. Extension Length "" [1] F _ Fiberglass insulation stranded conductor stainless steel overbraid Polyimide insulation stranded K _ conductor stainless steel overbraid [1] Insert digit "" length in inches. EX: F0=" "" length. 1 ayonet ap Style E 7/16" I.D. single slot (standard) (not available with Opt. tip) 1 mm I.D. dual slot 1 mm O.D. dual pin 15 mm ID dual slot 1 Tip and Spring Diameters TIP O.D. "D" DIM. SPRING O.D. "Q" DIM Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnects X ox connector LS 1" long spring (/16" O.D. only) 006 Pyromation, Inc. PL Distributed y: M&M ontrol Service, Inc
5 onfiguration ode PL0 rmordjustable Immersion Thermocouples The J series armoradjustable immersion thermocouple has a bayonet cap on the flexible armor and allows for immersion for the entire specified '' dimension. This assembly is used in a variety of applications (with a bayonet adapter) where ease of installation and quick disconnect is preferred. Standard and metric size bayonet caps and adapters are available. 1/" 6" STNDRD D Q ORDER S J U F0, X 11 Thermocouple Type TYPE SINGLE DUPLEX J JJ J K KK K For type E and T thermocouples, replace J in order code with required letter designation. 1 ayonet ap Style D E 1 Junction 7/16" I.D. single slot (standard) 1 mm I.D. dual slot 1 mm O.D. dual pin Positive seat indicating 15 mm I.D. dual slot 1 Tip and Flex rmor Diameters TIP O.D. "D"DIM. FLEX O.D. "Q" DIM Grounded junctions supplied as standard. Insert "U" only when requiring an ungrounded junction. Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 X " split leads with 1/" female disconnects ox connector Extension Leadwire "" + "" [1] F1 _ F _ Fiberglass insulation solid conductor flexible armor Fiberglass insulation stranded conductor flexible armor [1] Insert digit "" length in inches. EX: F106=6" "" length; for assemblies requiring other than the standard 6" "" dimension, insert digit "" length in inches after "" dimension. EX: F10601=6" "" length with additional 1" leads beyond armor. 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL5
6 onfiguration ode PL0 rmordjustable Immersion RTDs The RTD version of an armoradjustable immersion sensor has a bayonet cap on the flexible armor and allows for immersion of the entire specified "" dimension. This assembly is used in a variety of applications (with a bayonet adapter) where ease of installation and quick disconnect is preferred. Standard and metric size bayonet caps and adapters are available. These coefficient of º 1 (IE lass ). Elements of other materials, values, and tolerances are available upon request. 1/" 6" STNDRD D Q ORDER S RF185 F01 11 RTD Element Type SINGLE DUPLEX [1] 1 ayonet ap Style D E 7/16" I.D. single slot (standard) 1 mm I.D. dual slot 1 mm O.D. dual pin Positive seat indicating 15 mm I.D. dual slot 1 Tip and Flex rmor Diameters TIP O.D. "D" DIM. ELEMENT ONNETION RF185 RF85 wire RF185 RF85 wire [1] Duplex not available with 1/8" O.D.; /16" O.D. limited to polyimide leadwire. FLEX O.D. "Q" DIM Extension Leadwire "" + "" [1] Fiberglass insulation stranded conductor F _ flexible armor Polyimide insulation stranded conductor K _ flexible armor [1] Insert digit "" length in inches. EX: F06=6" "" length; for assemblies other than standard that require leadwire beyond the flexible armor, insert digit "" length after armor length. EX: F0601=6" "" length with additional 1" leads beyond armor. Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnects X ox connector 006 Pyromation, Inc. PL6 Distributed y: M&M ontrol Service, Inc
7 onfiguration ode PL05 Fiberglass Meltolt Thermocouples The meltbolt thermocouple illustrated below is made of 00 series stainless steel and is constructed using a fiberglass insulated element. This style of thermocouple is used on extruders and injection molding machines to directly measure the melt temperature of plastic as it moves down the extruder barrel. T OLT LENGTH D 1/0 UNF OLT THRED, NOMINL THRED LENGTH 1 7/8" ORDER S JFM U 0 F Thermocouple Type TIP O.D. SINGLE DUPLEX "D" DIM. JFM 1/8 JFM JJFM /16 For type E, K, or T thermocouples, replace J in order code with required letter designation. 1 olt Length LENGTH 6 6 onsult factory for other lengths. 1 Junction Grounded junctions supplied as standard. Insert 'U' only when requiring an ungrounded junction. Tip Length "T" TIP LENGTH 00 Flush 08 1/ 0 1/8 1 / 0 1/ 16 1 onsult factory for other lengths. "T" TIP LENGTH Extension Leadwire "" [1] No leadwire, connector attached to 000 sheath Fiberglass insulation solid conductor F1 _ flexible armor Fiberglass insulation stranded F _ conductor flexible armor [1] Insert digit "" length in inches. EX: F101=1" "" length; for assemblies requiring other than the standard 6" "" dimension, insert digit "" length in inches after "" dimension. EX: F10601=6" "" length with additional 1" "" length. Terminations and " split leads, 1/" stripped " split leads with spade lugs 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL7
8 onfiguration ode PL06 Meltolt RTDs The meltbolt RTD sensor illustrated below is used on extruders and injection molding machines to directly measure the melt temperature of plastic as it moves down the extruder barrel. This sensor is made of 00 series stainless steel and is constructed 1 (IE lass ). Elements of other materials, values, and tolerances are available upon request. T OLT LENGTH D 1/0 UNF OLT THRED, NOMINL THRED LENGTH 1 7/8" ORDER S RF185M 0 F01 11 RTD Element Type ELEMENT SINGLE DUPLEX [1] ONNETION wire wire 1 Tip Diameter TIP O.D. "D" DIM. /16 Tip Length leadwire. 1 olt Length LENGTH 6 6 onsult factory for other lengths. "T" TIP LENGTH 00 Flush 1/ 0 1 / 0 1/ 16 1 onsult factory for other lengths. "T" TIP LENGTH Extension Leadwire [1] 000 No leadwire, connector attached to sheath F _ Terminations and Standard jack 6 7 X Fiberglass insulation stranded conductor flexible armor Polyimide insulation stranded conductor K _ flexible armor ox connector 006 Pyromation, Inc. PL8 Distributed y: M&M ontrol Service, Inc
9 onfiguration ode PL05 MgO and djustable Tip Meltolt Thermocouples The meltbolt thermocouples illustrated below are used on extruders and injection molding machines to directly measure the melt temperature of plastic as it moves down the extruder barrel. These meltbolts are made with 00 series stainless steel and are constructed using a metalsheathed MgO element. The fixed tip style consists of an MgO element brazed to the bolt at a specified tip length and is supplied with a grounded junction as standard. Pyromation's Precision Tip Readjustable Melt olt Thermocouples come standard with a fast response exposed junction. The precision tip is manufactured from hardened stainless steel and creates a positive shut off to prevent the back flow of plastic into the bolt. The 5/" O.D. tip has an adjustment range of 0"1". T OLT LENGTH 0" 1" DJUSTLE X /" /" D 1/0 UNF OLT THRED, NOMINL THRED LENGTH 1 7/8" 5/" 1/0 UNF OLT THRED NOMINL THRED LENGTH 1 7/8" 1/8" GRDUTED MRKINGS ORDER S ExampleOrder Number: 11 1 JMM U or Thermocouple Type SINGLE DUPLEX TIP O.D. "D" DIM. OLT LENGTH TIP STYLE JMM JJMM 1/8" " Fixed JMM JJMM 1/8" " Fixed JMM6 JJMM6 1/8" 6" Fixed JMM JJMM /16" " Fixed JMM JJMM /16" " Fixed JMM6 JJMM6 /16" 6" Fixed JME JJME 5/" " djustable JM6E JJM6E 5/" 6" djustable For type E, K or T thermocouples, replace J in order code with required letter designation. Tip Length for Fixed Tip Meltolt "T" TIP LENGTH "T" TIP LENGTH 00 Flush 08 1/" 0 1/8" 1 /" 0 1/" 16 1" Tip Length for djustable Tip Meltolt "T" TIP LENGTH 01 djustable range 0" to 1" MgO Extension "" 000 onnector 1/" from bolt _ Insert "" length in inches using digits 1 Junction Grounded junctions supplied as standard on fixed tip meltbolts and exposed tip junctions are standard on adjustable tip meltbolts. For junction styles other than the standard, specify "U" for ungrounded or "G" for grounded junction. Terminations and L ompression L bracket 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL9
10 onfiguration ode PL07 NozzleMelt Thermocouples and RTDs The nozzlemelt temperature sensors listed below are typically placed into the nozzle of a plastic injection molding machine and sense the temperature of the molten plastic prior to being injected into the mold. They are offered in a variety of thermocouple types as listed below. The RTDs are constructed using a 100 platinum element with a temperature coefficient of º 1 (IE lass ). Elements of other materials, values, and tolerances are available upon request. 1/" MINIMUM 1 /" ROTTING OLT /8 UNF TIP 1 /8" MINIMUM 1 1/" Ø0.10" FLEX 1/8" ORDER S 1 or 1 JNM 0 F06, X 1 Thermocouple Type, Tip Length, and Sheath Style TIP LENGTH END JNM1 1/8" Straight JNM1 1/" Straight JNM 1/8" 5º JNM 1/" 5º JNM 1/8" 90º JNM 1/" 90º For type E, K, or T thermocouples, replace J in order code with required letter designation. 1 RTD Type, Tip Length, and Sheath Style TIP LENGTH END RF185NM1 1/8" Straight RF185NM1 1/" Straight RF185NM 1/8" 5º RF185NM 1/" 5º RF185NM 1/8" 90º RF185NM 1/" 90º ll RTDs are supplied as wire constuction. Replace the in the part number with a for wire construction. Sheath extension "" Insert '' dimension in inches using digits. Extension Length "" [1] 000 No leadwire, connector attached to sheath F1 _ Fiberglass insulation solid conductor F1 _ F _ F _ Fiberglass insulation solid conductor flexible armor Fiberglass insulation stranded conductor Fiberglass insulation stranded conductor flexible armor Fiberglass insulation stranded conductor F _ stainless steel overbraid [1] Insert digit "" length in inches. EX: F101=1" "" length; for assemblies requiring other than the standard 6" "" dimension, insert digit "" length in inches after "" dimension. EX: F10601=6" "" length with additional 1" "" length. Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnects X ox connector 006 Pyromation, Inc. PL10 Distributed y: M&M ontrol Service, Inc
11 onfiguration ode PL08 Threaded Nozzle Thermocouples The threaded nozzle thermocouple illustrated below is generally used to measure the temperature of the nozzle of an injection molding machine. This style is not in direct contact with the molten plastic. Due to the relatively small size of this sensor, other general areas of use include mounting in bearing housings, sealing bars, heat plates, and other limited space applications. ROTTING OLT D TIP ORDER S 11 1 JTN U F6 F10 11 Thermocouple Type JTN 1 Junction Grounded junctions supplied as standard. Insert "U" only when requiring an ungrounded junction. olt Designation NOZZLE SIZE THREDS Iron onstantan For type E, K or T thermocouples, replace J in order code with required letter designation. "D" TIP "" LENGTH F6 1/" 8 /16 /8" G8 /8" 1/ 1/" I6 6 mm x 1 mm /16 10 mm K6 8 mm x 1.5 mm 1/ 10 mm M10 10 mm x 1.50 mm 1/ 16 mm Other bolt sizes available; consult factory. Extension Length "" [1] F1 _ F1 _ F _ Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnects X WIRE Fiberglass insulation solid conductor Fiberglass insulation solid conductor stainless steel overbraid Fiberglass insulation stranded conductor Fiberglass insulation stranded F _ conductor stainless steel overbraid [1] Insert digit "" length in inches. EX: F0=" "" length. ox connector 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL11
12 onfiguration ode PL09 Threaded Nozzle RTDs The threaded nozzle RTD illustrated below is generally used to measure the temperature of the nozzle of an injection molding machine. This style is not in direct contact with the molten plastic. Due to the relatively small size of this sensor, other general areas of use include mounting in bearing housings, sealing bars, heat plates, and other limited space applications. These assemblies are supplied standard using a 100 ohm platinum element with a temperature coefficient of º 1 (IE lass ). Elements of other materials, values, and tolerances are available upon request. ROTTING OLT D TIP ORDER S 1 RF185TN F6 F01 1 RTD Element Type RF185TN RF185TN olt Designation NOZZLE SIZE THREDS ELEMENT ONNETION wire wire "D" TIP '""' LENGTH F6 1/" 8 /16 /8" G8 /8" 1/ 1/" I6 6 mm x 1 mm /16 10 mm K6 8 mm x 1.5 mm 1/ 10 mm M10 10 mm x 1.50 mm 1/ 16 mm Other bolt sizes available; consult factory. Extension Length "" [1] WIRE F _ Fiberglass insulation stranded conductor Fiberglass insulation stranded conductor F _ stainless steel overbraid K _ Polyimide insulation stranded conductor K _ Polyimide insulation stranded conductor stainless steel overbraid [1] Insert digit "" length in inches. EX: F0=" "" length Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnects X ox connector 006 Pyromation, Inc. PL1 Distributed y: M&M ontrol Service, Inc
13 onfiguration ode PL10 Ring Thermocouples The ring type assemblies pictured below have the thermocouples embedded either into a stainless steel stamping for grounded junctions (figure 1) or a brass ring for ungrounded junctions (figure ). Various ring sizes are available to measure the surface temperature of nozzles, extruder barrels, die heads, molds, and many other applicable surfaces. FIGURE 1 FIGURE W L 1/16" THIK W L I.D. 1/" THIK I.D. Ø /16" X /" LONG ORDER S 1 JRS1 F01 8 FIGURE 1 1 Grounded Thermocouples Ring Size RING SIZE I.D. W L SREW or OLT SIZE JRS1 0.0 /8 7/8 #6 #10 mm5mm JRS 0. 7/16 1 JRS 0. 9/16 1 1/8 FIGURE 1 Ungrounded Thermocouples Ring Size RING SIZE I.D. W L #1, 1/" 5/16" 5mm 8mm 5/16" /8" 8mm 10mm SREW SIZE JR1U 0.0 /8 5/8 #6 #10 mm5mm JRU 0. 5/8 7/8 JRU 0. 5/8 7/8 #1, 1/" 5/16" 5mm 8mm 5/16" /8" 8mm 10mm For type E, K, or T thermocouples, replace J in order code with required letter designation. Extension Leadwire "" [1] F1 _ F1 _ F _ F _ T1 _ T _ K1 _ Fiberglass insulation solid conductor Fiberglass insulation solid conductor stainless steel overbraid Fiberglass insulation stranded conductor Fiberglass insulation stranded conductor stainless steel overbraid Fluoropolymer insulation solid conductor Fluoropolymer insulation stranded conductor Polyimide insulation solid conductor [1] Insert digit "" length in inches. EX: F0=" "" length. Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnect lugs X ox connector 006 Pyromation, Inc. 167 Distributed y: M&M ontrol Service, Inc PL1
14 onfiguration ode PL11 Ring RTDs The ring type assembly pictured below has the RTD element embedded into a brass ring. Various ring sizes are available to measure the surface temperature of nozzles, extruder barrels, die heads, molds, and many other applicable surfaces. This 1 (IE lass ). Elements of other materials, values, and tolerances are available upon request. W L 1/" THIK I.D. Ø /16" X 1 1/" LONG ORDER S 1 1 RF185R F01 11 RTD Element Type SINGLE DUPLEX [1] 1 Ring Size I.D. W L ELEMENT ONNETION wire [1] Duplex assemblies available with polyimide or fluoropolymer wire only. SREW SIZE #6 #10 mm 8mm 10mm Extension Leadwire Type and "" + "" Dimension [1] WIRE Fiberglass insulation stranded conductor Fiberglass insulation stranded conductor flexible armor Fiberglass insulation stranded conductor stainless steel overbraid Fluoropolymer insulation stranded conductor Fluoropolymer insulation stranded conductor flexible armor Polyimide insulation stranded conductor Polyimide insulation stranded conductor flexible armor Polyimide insulation stranded conductor stainless steel overbraid Terminations and Standard jack 8 X ox connector 006 Pyromation, Inc. PL1 Distributed y: M&M ontrol Service, Inc
15 onfiguration ode PL1 Spade Thermocouples and RTDs The temperature sensors illustrated below are generally used for surface temperature measurement. The series SS and ST spade thermocouples are sandwiched between two thin shims of either stainless steel or two pieces of fiberglass tape. They can be attached using a worm drive hose clamp or by placing under heater bands. These spades can be formed and secured to the outside of various size tubes, pipes, or nozzles. The SK series sensors are sealed in epoxy between two layers of polyimide tape and are provded with an adhesive backing for easy attachment to many surfaces. The SK series sensors are available in various thermocouple types or RTDs. The RTDs are constructed using a (IE lass ). 1 /16" 1" 1" 1" 1" 1" ORDER S 1 JSS F106 1 Thermocouple Type JSS Stainless steel spade JST max Flexible Polyimide spade with adhesive JSK tape backing Nominal spade thickness is 0.00" min to 0.090" max For type E, K, or T thermocouples, replace J in order code with required letter designation. 1a RTD Type 100 Platinum = RF185SK wire ELEMENT ONNETION Flexible polyimide spade with adhesive tape backing Flexible polyimide spade with adhesive tape backing Nominal spade thickness is 0.060" min to 0.100" max Extension Leadwire "" [1] F1 _ Fiberglass insulation solid conductor F1 _ _ Terminations and " split leads, 1/" stripped " split leads with spade lugs 8 " split leads with 1/" female disconnects X Fiberglass insulation solid conductor stainless steel overbraid Fiberglass insulation stranded conductor _ Fiberglass insulation stranded conductor stainless steel overbraid T1 _ Fluoropolymer insulation solid conductor _ Fluoropolymer insulation stranded conductor K1 _ Polyimide insulation solid conductor ox connector 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL15
16 onfiguration ode PL1 Insulated Wire Type Thermocouples The multiplepurpose thermocouples listed below are constructed with insulated thermocouple wire and provided with twisted and TIGwelded hot junctions. Insulations and overbraids are offered to satisfy many industrial processes, furnace certification, load checking, and laboratory test temperature measurement applications. " OPTION 1" /16" OPTION L ORDER S 1 K01S Thermocouple and Insulation Type (Insert T/ Type WIRE G. OND. TYPE [1] TEMPERTURE RTING ERROR [] (J,K,E) Solid Fiberglass 8 º [900 ºF] Standard (J,K) 01S0 0 Solid Fiberglass/SS ovb. 8 º [900 ºF] Standard (K) 00 0 Strnd Fiberglass 8 º [900 ºF] Standard (J,K) 0S17 0 Strnd Fiberglass/SS ovb. 8 º [900 ºF] Standard (J,K) 01 0 Solid Hitemp fiberglass 70 º [100 ºF] Special (J,K) Solid TFE 60 º [500 ºF] Standard (J,K) Solid Polyimide 16 º [600 ºF] Special (K) Solid Vitreous sil. fiber 871 º [1600 ºF] Special (K) Solid eramic fiber 10 º [00 ºF] Special (K) 0N50 0 Solid er.fiber/inc. ovb. 10 º [00 ºF] Special (J,K) 10 Solid Fiberglass 8 º [900 ºF] Standard (J,K) 1508 Solid TFE 60 º [500 ºF] Standard (J,K) Solid Fiberglass 8 º [900 ºF] Standard (J,K,T) Solid FEP 0 º [00 ºF] Special [1] See Wire Section, for additional insulation specifications. [] onsult factory for availability of nonlisted Special Limits of Error wire. Terminations and 0 Leads not stripped " split leads, 1/" stripped Leads split " with spade lugs L Mating connector Ungrounded hot junction " ceramic insulator at hot junction Length Insert Digit Length Order ode in Inches. 006 Pyromation, Inc. PL16 Distributed y: M&M ontrol Service, Inc
17 onfiguration ode PL1 Flexible Thermocouple Extensions The flexible thermocouple extensions illustrated below are constructed using thermocouple wire or thermocouple extension wire. They are used as extension cords to provide suitable connections between sensors, jack panels, or instrumentation. 6" TYPIL ORDER S 1 JE6, F106, 1 Terminations and JE1 JE JE JE JE5 JE6 JE7 " split leads with compensated spade lugs " split leads, 1/" stripped " split leads with spade lugs Standard plug Standard jack Miniature plug Miniature jack " split leads with 1/" JE8 female disconnects For type E, K, or T thermocouples, replace J in order code with required letter designation. X G R SP ox connector 1/" NPT plastic cord grip Rubber boot Solid pin plug Extension Leadwire "" + "" Dimension [1] F1 _ F1 _ F1 _ F _ F _ F _ T1 _ T1 _ T _ T Fiberglass insulation solid conductor Fiberglass insulation solid conductor flexible armor Fiberglass insulation solid conductor stainless steel overbraid Fiberglass insulation stranded conductor Fiberglass insulation stranded conductor flexible armor Fiberglass insulation stranded conductor stainless steel overbraid Fluoropolymer insulation solid conductor Fluoropolymer insulation solid conductor flexible armor Fluoropolymer insulation stranded conductor Fluoropolymer insulation stranded conductor flexible armor PV insulated stranded conductor coil cord (only available in 60" and 10" extended lengths) [1] Insert digit "" length in inches. EX: F106=6" "" length; for assemblies requiring other than the standard 6" "" dimension, insert digit "" length in inches after "" dimension. EX: F10601=6" "" length with additional 1" "" length. For PVcoated or FEP coated flex, substitute suffix code with P for PV and T for FEP coating. Example: FP is stranded fiberglass leads with PV flex. Terminations and 0 No termination 1 " split leads with compensated spade lugs " split leads, 1/" stripped " split leads with spade lugs 8 X G R SP " split leads with 1/" female disconnect lugs ox connector 1/" NPT plastic cord grip Rubber boot Solid pin plug 006 Pyromation, Inc Distributed y: M&M ontrol Service, Inc PL17
18 onfiguration ode PL15 Flexible RTD Extensions The flexible RTD extensions illustrated below are constructed using stranded copper wire with various insulations. They are used as extension cords to provide suitable connections between sensors, jack panels, or instrumentation. 6" TYPIL ORDER S 1 RTE, F06 1 Terminations and WIRE WIRE RTE RTE " split leads, 1/" stripped RTE RTE " split leads with spade lugs RTE RTE RTE5 RTE RTE6 RTE RTE7 RTE RTE8 X G R RTE8 " split leads with 1/" female disconnects ox connector 1/" NPT plastic cord grip Rubber boot Extension Leadwire and "" + "" Dimension [1] F _ F _ F _ T _ T _ K _ K _ K Fiberglass insulation stranded conductor Fiberglass insulation stranded conductor flexible armor Fiberglass insulation stranded conductor stainless steel overbraid Fluoropolymer insulation stranded conductor Fluoropolymer insulation stranded conductor flexible armor Polyimide insulation stranded conductor Polyimide insulation stranded conductor flexible armor Polyimide insulation stranded conductor stainless steel overbraid PV insulated stranded conductor coil cord (only available in 60" and 10" extended lengths) [1] Insert digit "" length in inches. EX: F106=6" "" length; for assemblies requiring other than the standard 6" "" dimension, insert digit "" length in inches after "" dimension. EX: F10601=6" "" length with additional 1" leads beyond armor. For PVcoated or FEP coated flex,substitute suffix code with P for PV and T for FEP coating. Example: TP is stranded Fluoropolymer leads with PV flex. Terminations and 0 No termination " split leads, 1/" stripped " split leads with spade lugs " split leads with 8 1/" female disconnects X G R ox connector 1/" NPT plastic cord grip Mating connector Rubber boot 006 Pyromation, Inc. PL18 Distributed y: M&M ontrol Service, Inc
Plastic B26650 ORDER CODES. Configuration Code PL01 General-Purpose Tube and Wire Thermocouples TOLERANCES TOLERANCES. Example Order Number:
onfiguration ode P01 GeneralPurpose Tube and ire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications
More informationPlastic. General Purpose Tube and Wire Thermocouples ORDER CODES. Example Order Number:
General Purpose Tube and Wire Thermocouples The thermocouples described below are commonly used in the plastic process industry. These assemblies can be used in many general applications where a 1/8" NPT
More informationORDER CODES CODE SINGLE DUPLEX TRIPLEX E EE - J JJ JJJ K KK KKK T TT - N NN -
MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity
More informationORDER CODES CODE. Special limits of error High-Purity MgO Insulation (99.4% Pure) Use this table only if options are desired.
MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity
More informationMgO ORDER CODES. 1-1 Thermocouple Types CODE
MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations A Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hardpacked standard
More informationThermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances
Watlow is a world class supplier of temperature measurement products, with more than 90 years of manufacturing, research and design expertise. Companies engaged in critical process control of food and
More informationThermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA
Watlow is a world class supplier of temperature measurement products, with more than 90 years of manufacturing, research and design expertise. Companies engaged in critical process control of food and
More informationThermocouples W A T L O W
W A T L O W Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions of thermocouples for
More informationMaximum Temperature Rating 200 C ORDER CODES CODE DESCRIPTION. 4 Head Terminations CODE DESCRIPTION 8HN63 9HP63
Configuration Code SP01 FEP-Coated Thermocouple Assemblies Configuration Code SP02 FEP-Coated RTD Assemblies The assemblies listed below are designed for a broad range of applications that require resistance
More informationGeneral Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG
More informationMGO Thermocouples. Controls. Connection Head. Connection Head. Thermowells. Junction Fittings. Connectors Connection Heads.
Connection Head Type J, K, T and E Grounded Ungrounded Exposed Sheath Materials 304 Stainless Steel 316 Stainless Steel Inconel 600 Standard Aluminum Aluminum Flip Top Cast Iron/Aluminum 316 Stainless
More informationHEATERS AND THERMOCOUPLES
HEATERS AND THERMOCOUPLES THERMOCOUPLES & RTD SENSORS MARATHON HEATER 808 Hackberry Lane HCR 3, Box 86E Del Rio, TX 78840 (830) 775-1417 Fax (830) 775-4379 www.marathonheater.com Marathon Heater is pleased
More informationThermocouple & RTD Accessories (Thermowells, Connectors & Fittings)
Thermocouple & RTD ccessories (Thermowells, onnectors & Fittings) TLE OF ONTENTS ESSORIES FOR THERMOOUPLE & RTD s MODEL DESRIPTION PGE P SERIES THERMOWELLS 96 X1 THERMOOUPLE EXTENSION LES 97 X2 RTD EXTENSION
More informationAdjustable Bayonet Thermocouple
Adjustable Bayonet Thermocouple 3 16 Diameter is standard 1 2 Probe Length is standard Lead Length Termination Easily obtaining a desired probe depth, the adjustable bayonet sensor uses a tension spring
More informationRAPID SHIP SENSORS, STOCK WIRE
W A T L O W RAPID SHIP SENSORS, STOCK WIRE AND CONNECTORS ISO 900 : 2000 Registered Company Richmond, Illinois USA 2005 New Rapid Ship Program Responds to Your Immediate Sensing Needs Capabilities Watlow
More informationThermocouples W A T L O W
W A T O W Watlow s mineral insulated thermocouples are fast-responding, durable, and capable of handling high temperatures. These thermocouples are manufactured with best-in-class XACTPAK, Watlow s trademark
More informationCerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated.
MGO Thermocouples Thermo Sensors MGO thermocouple insulation materials feature Cerampak. These MGO thermocouples are recommended where the thermocouple is immersed in liquids, high moisture, corrosive
More informationPlastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19
Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19 A wide variety of thermocouples commonly used in the plastics industry, suitable for high and low temperatures applications. Available in a choice
More informationTemperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product
Series TCM Multipoint Thermocouple Assemblies Multipoint Thermocouples are used in a broad range of processes and installations to monitor the temperature in multiple positions or elevations. These sensors
More informationFor the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB
Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process
More informationElectronic Temperature Sensor
Connection Head Type RTD or Element or RTD Cast Aluminum, Polypropylene or Stainless Steel Head Weather Proof Welded or Spring Loaded TDD TMD Hot Junction: Head Process Connection Conduit Connection 100Ω
More informationSensors. Table of Contents. Remote Mounted Model 1340 (A-3) Field Adjustable (A-4) General Purpose (A-24)... 4
Sensors Table of Contents page Remote Mounted Model 1340 (A-3)... 2 Field Adjustable (A-4)... 3 General Purpose (A-24)... 4 Connectors and Accessories (A-30 & 31)... 5 Multiple Sensor Assembly (A-25)...
More informationSection 3 Index Furnace Tube Skin Thermocouples
Section 3 Index Furnace Tube Skin Thermocouples Thermocouple Assemblies Model Page O1 Bare End Terminations 3-1 O2 Lead Wire Extension 3-2 O3 SS Flex Armor Extension 3-3 O4 CGB Over SS Flex Armor 3-4 Thermocouple
More informationFor the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB
Electrical temperature measurement For the plastics machinery industry Adjustable bayonet Model TC47-AB WIKA data sheet TE 67.20 Applications Plastics and rubber industry For direct installation into the
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths
More informationAccuTru ExL Furnace Tubeskin Thermocouples
S E N S O R T E C H N O L O G I E S AccuTru ExL Furnace Tubeskin Thermocouples Dedicated to those organizations that value improved temperature measurement for critical processes S E N S O R T E C H N
More informationStandard wire insulation is glass over glass with a stainless steel overwrap. Dual and single element. MgO versions available. rubber outer jacket.
www.tcproducts.com 1-800-727-5646 Thermo-Couple Products Co. T C P engine exhaust and compressor thermocouples are available in a variety of configurations to satisfy many different requirements. The standard
More informationSECTION 7: MINIATURE SENSORS
SECTION 7: MINIATURE SENSORS Embedment sensors install in bearings for over-temperature protection Small, rugged RTDs and thermocouples withstand rough handling and harsh environments Certified non-sparking
More informationMineral Insulated Resistance Thermometers (RTD)
Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types
More informationN I S T traceable calibration equipment conforms to MIL-STD-45662A.
www.tcproducts.com 1-800-727-5646 Thermo-Couple Products Co. Turbine RTD's are used for bearing temperature measurement which provides safe and accurate monitoring. The RTD designs offer a resistance value
More informationNOZZLE HEATER BANDS. Part No. Standard Metric Watts Volts Quantity Prices
Page 84 NOZZLE HEATER BANDS 12 STANDARD FLEXIBLE LEADS Available in 120 or 240 Volts Superior Mica Construction Flange Lock-Up Strain relief for ultimate lead protection In Stock IMMEDIATE SHIPMENT Part
More informationSEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399
DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is
More informationTHERMOCOUPLE AND RESISTANCE THERMOMETER CABLES
THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES ABOUT LABFACILITY Formed in 1971, Labfacility specialises in the field of Temperature and Process Measurement. We are the largest UK manufacturer of both
More informationShort Form Catalogue AJ Thermosensors
Thermocouples Short Form Catalogue AJ Thermosensors Resistance thermometers Head mounted Probe style Application specific Accessories See the individual datasheets for more detailed information on each
More informationSpring-Loaded MgO Thermocouple/ Thermowell Assemblies with Connection Heads (GP04, XP04, XP06)
Operating Instructions Connection Heads (GP04, XP04, XP06) Beyond Measure Speed, Service, Solutions PYROMATION P/N: -006-SL-8HN31 IOIGP04 08/14 Choosing the right temperature sensor for each application
More informationHot Runner Thermocouples Model TC46
Electrical Temperature Measurement Hot Runner Thermocouples Model TC46 WIKA Data Sheet TE 65.46 Applications Plastics and rubber industry Hot Runner bushings, drops and nozzles Hot Runner manifolds Moulds
More informationTHIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG
THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG COMPANY OVERVIEW Since 1970, we have been pioneering new developments in heater technology and providing
More informationhotrod Cartridge Heaters
hotrod Cartridge Heaters hotrod Cartridge Heaters Components We provide our customers with an extensive portfolio of ments, thermal sensors and control technology. Since 1973, we have manufactured heating
More informationHot runner thermocouple Model TC46
Electrical temperature measurement Hot runner thermocouple Model TC46 WIKA data sheet TE 65.46 for further approvals see page 7 Applications Plastics and rubber industry Hot runner bushings, drops and
More informationProbe Type Accuracy Handle Shaft Cable Plug Model Surface Probes Max. temp. at tip 7 sec. 220 C 428 F Response time
Probe Type Accuracy Handle Shaft Cable Plug Technical data probes type K : K type thermocouple : Class I Premium grade : ABS, 110 mm long, 90 C max. : Stainless steel : 1000 mm standard. Coiled polyurethan
More informationValves, MRO Items, Heaters, Thermocouples, and so much more
Nozzle Tips, Nozzle Bodies, Valves, MRO Items, Heaters, Thermocouples, and so much more (800) 521-0704 Fax: (810) 227-2266 37 Summit Street, Brighton, MI 48116 37 Summit Street, Brighton, MI 48116 810.227.2266
More informationhotrod Cartridge Heaters Application Fields
For heating applications: - Packaging machines - Extruders - Casting machines - Hot melt - Cutting knives - Analytical equipment in laboratories Custom options: - Power distribution - Numerous attachments
More informationFor the plastics machinery industry Manifold thermocouple Model TC47-MT
Electrical temperature measurement For the plastics machinery industry Manifold Model TC47-MT WIKA data sheet TE 67.21 Applications Plastics and rubber industry Hot runner manifolds for injection mould
More informationResistance Temperature Detectors (RTDs)
Website: Resistance Temperature Detectors (RTDs) Resistance Temperature Detectors (RTD's). These detectors are frequently used in the plastics industries and many others. Care must be taken to eliminate
More informationTEMPERATURE SENSOR ASSEMBLIES (PROBE)
Discription: TEMPERATURE SENSORS A temperature sensor is an element that sensed the temperature changes, then translate the measured temperature into an electrical signal which then providing the data
More informationSpring-Loaded RTD/Thermowell Assemblies with Connection Heads (GP03, XP03, XP05)
Operating Instructions (GP03, XP03, XP05) Beyond Measure Speed, Service, Solutions PYROMATION P/N: -006-SL-8HN31 IOIGP03 07/14 Choosing the right temperature sensor for each application is critical, but
More informationTEMPERATURE SENSORS TEMPERATURE SENSORS
TEMPERATURE SENSORS TE Connectivity is a leader in the design and manufacture of NTC thermistors, RTDs, thermocouples, thermopiles, digital output and customized sensor assemblies. Building on our long
More informationCartridge Heaters CARTRIDGE
Hotwatt manufactures a wide range of cartridge heating units for a variety of applications. This size, sheath, leads, terminals, wattage and voltage can be adapted to your heating requirements. Hotwatt
More informationPRODUCT DATA. Pt100 Probe, PTFE Lead. Pt100 sensing resistor in stainless steel sheath, PTFE insulated extension lead.
PRODUCT DATA Pt100 Probe, PTFE Lead Pt100 sensing resistor in stainless steel sheath, PTFE insulated extension lead Sensor type Tip temperature rating Extension cable Pt100 Class B, 4 wire to IEC 60751
More informationInstallation Instructions
K-Series Constant-Wattage Heating Cable Installation Instructions Read and understand this material before installing this heater. Failure to understand how to safely install the heater could result in
More informationTemperature Sensors. Request Quote
see more at SORInc.com Request Quote Temperature s SOR manufactures a complete line of thermocouple elements, Resistance Temperature Detector (RTD) sensors, thermowells, industrial assemblies and specialty
More informationCartridge Heaters. Standard Terminations
Standard Terminations Innovative Cartridge Heater Terminations Focused on Providing Maximum Performance Under a Diverse Segment of Demanding pplications We offer a selection of over 40 standard terminations
More information3 Terminals, Kits and Tools
3 Terminals, Kits and Tools Glossary of Product Terminology 2 Terminals 5 Butt onnectors 5 Disconnects 11 Female 11 Male 17 Multi-Stack 22 Ring Tongue Terminals 23 For more than 30 years, 3M has been a
More informationTHERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx
THERMOCOUPLE CABLE Customization Customized colour option and printing of the outer sheath on request Compensating & Extension 1601 Application: Compensating or Extension Cables are used in temperature
More informationRTI-4. Flexible Sensor Temperature Assemblies. Features Multiple mounting possibilities. Anywhere a temperature measurement is needed.
November 2015 The Versatile WORM mounts anywhere a temperature measurement is needed. Featuring Moore Industries innovative WORM Flexible Sensor, these versatile temperature assemblies mount directly to
More informationHotset High-Watt Density Cartridge Heaters
Cartridge Heaters hotset High-Watt Density Cartridge Heaters Hotset High-Watt Density Cartridge Heaters proven technology founded on our long term experience with many outstanding advantages. For applications
More informationCastle Model TSM-21 Standard Screw Pocket Machine
Castle Model TSM-21 Standard Screw Pocket Machine "For Models with Serial Number 62481 and Above" Items Included with Machine Part No. Description Qty B00964 Castle 9/64 Cobalt Drill Bit w 1/4" Shank 1
More informationACCESSORIES 204 ACCESSORIES
ESSORIES E S S O R I E S rystal Fountains manufactures a select line of water feature accessories. From swivel units to help align spray nozzles to hydraulic fill valves, rystal Fountains manufactures
More informationOmnigrad S -TC65. Technical Information
Technical Information Omnigrad S T65 Thermocouple thermometer EExd certified, no replaceable insert, no thermowell, process connection threaded fixed or compression fitting PP (4...20 ma), HART or PROFIBUSPA
More informationTubing & Hose Metric. Nylon, Polyurethane, Polyester Reinforced PVC, Metal Braided Rubber, Copper, Double Wall Brazed Steel
Tubing & Hose Metric Nylon, Polyurethane, Polyester Reinforced PVC, Metal Braided Rubber, Copper, Double Wall Brazed Steel Available in a variety of different types to suit a wide range of applications
More informationContents. Sensors & Transducers. Page
Farnell Page 1603 Date: 22-08-06 time:03:52 Contents Page Accelerometers 1625 Conductive Level Controllers 1629 Current Transducers 1657 Displacement Sensors 1634 Encoders - Absolute 1633 Encoders - Accessories
More information3 Terminals, Kits and Tools
3 Terminals, Kits and Tools Glossary of Product Terminology 2 Terminals 6 For more than 30 years, 3M has been a leading supplier of Scotchlok terminals, disconnects, connectors and tools for use in the
More information( )
(1-800-492-8826) OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels
More information(770)
(770) 345-0010 OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels
More informationSOLENOID VALVES direct operated core disc 1/4
SOLENOI VLVES direct operated core disc /4 N U NO / Series 4 FETURES ompact valve intended for single-acting actuator control Epoxy moulded coil for general service applications oils interchangeable without
More informationDiameters 10 Length w/ Coupling 5 Length w/ Coupling Trade Size Metric Size OD ID Wt./Ft. Type 304 Type 316 Type 304 Type 316
STINLESS STEEL ONDUIT Diameters 10 Length w/ oupling 5 Length w/ oupling Trade Size Metric Size OD ID Wt./Ft. Type 04 Type 16 Type 04 Type 16 ½ 16 0.840 0.620 0.82 S40510T00 S60510T00 S40505T00 S60505T00
More informationPPT 802, Proximity Probe Transducer System
PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current
More informationSECTION 8: STATOR WINDING SENSORS
SECTION 8: STATOR WINDING SENSORS Install between stator windings for continuous protection of motors and generators Increased safety sensors for use in hazardous areas Single and dual elements offer high
More informationHigh-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability
High-Flow Stainless Tubes H11 ll stainless construction for high strength and durability Use with all PCS cascades J in part number indicates next largest thread TUE TUE L = 12 18 24 36 HF093T-.090.076
More informationCartridge Heaters W A T L O W FIREROD. Cartridge Heaters
W A T L O W The Watlow revolutionized the heating element industry in 94 when it was patented as the first swaged cartridge heater. With premium materials and tight manufacturing controls, the heater continues
More informationArticle on Sheath materials, Thermowells, Fittings, and Terminations
Article on Sheath materials, Thermowells, Fittings, and Terminations 1. INTRODUCTION Temperature sensor element for laboratory and industrial use should normally be protected by some form of sheath or
More informationCold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions
Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Class I Indoor Termination Voltage Designation: 12/20(24) kv Kit Contents: 1 HeatShrinkBreakoutBootAssembly 3 HeatShrinkBindingSleeves
More informationAluminum Mechanical Lugs
luminum Mechanical ugs MNI INUSTRI ONNTORS One- and Two-onductor luminum ugs Suitable for use with either copper or aluminum conductors Manufactured from high strength 6061-T6 aluminum alloy lectroplated
More informationCable thermocouple Model TC40
Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 Applications For direct installation into the process Machine building Motors Bearings Pipelines and vessels Special
More informationPF Coil Fabrication Overview
PF Coil Fabrication Overview PF Coils Information Meeting Barcelona - 15 th October 2012 This presentation is intended for reference purposes only and is not a legally binding document PF Building Layout
More informationDirect Automation Trade Price List Process Controls Sensors 1
Direct Automation Trade Price List Process Controls Sensors 1 Sensor & Input Devices Process Controls & Sensors Process/Temperature Controllers & Assessories DPM2-AT-2R-HL ProSense digital panel meter,
More informationHow to Replace a Switch
How to Replace a Switch The switches are the ones most frequently replaced, either because a switch has failed or because you want to substitute a newer type. Before deciding that a switch has failed,
More information4 BADGER Rotary Cleaning for Medium Pipes with Elbows
4 BADGER Rotary Cleaning for Medium Pipes with Elbows TOOL TALK 2.75 in. 70 mm The 4 Badger self-rotary tool makes cleaning pipes with elbows easy, navigating 4 inch (102 mm) bends with controlled rotation
More informationNon-Metallic, Armored Cable, and Flexible Metallic Conduit Fittings
Non-Metallic Sheathed Cable and Portable Cord Connectors Non-Metallic Sheathed Cable Connectors Armored Cable and Flexible Connectors Armored Cable and Flexible Connectors Armored, Metal Clad, and Non-Metallic
More informationSOLENOID VALVES direct operated core disc 1/4
SOLENOI VLVES direct operated core disc / N U NO / Series 70 FETURES Three-way solenoid valves with orifice and pipe connections in valve body enabling convenient installation ompact valve intended for
More information3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination
3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may
More informationÖLFLEX CLASSIC 115 CY
Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationRTD Insert for Temperature Sensor omniset- TPR100
Technical Information TI00268T/02/en/13.16 71329346 RTD Insert for Temperature Sensor omniset- TPR100 Mineral insulated insert Thermoresistance sensing element PCP (4...20 ma), HART or PROFIBUS-PA electronics
More informationHigh temperature sensors
Certificata IO 92 EI s.r.l. - via Milano, 11-22 ainate (MI) Tel.: (2) 937868 / 937342 - Fax: (2) 9371724 Home page: www.elsi.it e-mail: info@elsi.it High temperature traight thermocouple M1 with ceramic,
More informationDirect immersion resistance thermometer
Direct immersion resistance thermometer PLAIN STEM D100-101-102-103-160-162 CONFIGURATIONS General use RTD Product series PT100WT D100 D101 D102 D103 D160 D162 2 Features assembly The sensor can be immersed
More information3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits
3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.
More informationSanitary RTDs and Temperature Transmitters
SENSORS FOR FOOD AND LIFE SCIENCES. Product Information - SA/CT FOOD Sanitary RTDs and Temperature Transmitters Introduction Anderson-Negele s electronic temperature sensors combine our industry proven,
More informationTS Series TS Series
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com TS-6700-850 Series TS-5700-850 Series Electronic Remote Temperature Sensors General Instructions APPLICATION Electronic thermistor
More informationPneufit Inch Series Push-In Tube Fittings 1/8" to 1/2" Tube Sizes UNF to 1/2" NPT Thread Options
Section 1 Pneufit Inch Series Push-In Tube Fittings to 1/2" Tube Sizes 10-32 UNF to 1/2" NPT Thread Options Inch Series Product Numbering System..................FIT-1-2 Inch Series Shapes and odes.........................fit-1-3
More information3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series
3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working
More informationABG Cable Glands Installation Procedure
ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless
More informationFood, Dairy and Pharmaceutical
CP Sanitary Fitting Reference Data Sheet he CP (clean in place) sanitary connections illustrated on this page are the most commonly used fittings in food, dairy, beverage, pharmaceutical, and chemical
More informationFlexible Heaters. Silicone Rubber Heaters
Rugged, yet thin, lightweight and flexible the use of Watlow silicone rubber heaters is limited only by the imagination. With these heaters, heat can be put where it is needed. In the application process
More informationSurface thermocouple Model TC50
Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial
More informationGeneral Specifications
General Specifications Model RS and RN Resistance Temperature Sensor GS 06B04D01-00E GENERAL Model RS and RN Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in
More informationVDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications
VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,
More informationAutoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69)
Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69) A range of thermocouple sensors specifically designed to withstand the harsh conditions within autoclaves. Autoclave Load and Drain thermocouples
More informationCABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips
Tough and dependable, Woodhead cable grips and cord grip bodies are reliable workhorses in any plant environment. They serve as flexible holding devices used to pull cable, rope, or tubing into place,
More informationTerminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles
Terminator ZP/ Kit Electrically Heated TubeTrace Bundles Listed Cable System 17M Terminator ZP/ The following installation procedures are suggested guidelines for the installation of the Terminator ZP/
More informationSanitary RTDs and Temperature Transmitters
Sanitary RTDs and Temperature Transmitters Modular components provide maximum configuration flexibility Unique element-to-housing design eliminates exposed threads, lowers profile All stainless steel construction
More information