Temperature Sensors. NTC Thermistors. Descriptions. RTS-Raw 10K NTC Thermistor. Specifications: Dimensions (mm):
|
|
- Antony Lamb
- 6 years ago
- Views:
Transcription
1 NTC Thermistors Descriptions In many industrial sectors and fields of research, temperature is one of the most important parameters which decides about product quality, security, and reliability. Temperature sensors are manufacturered by variable technologies, according to the field of application. NTC(Negative Temperature Coefficient) Thermistors are manufactured from sintered metal oxides. Each thermistor consists of a combination of two to four of the following materials: Manganese, Nickel, Cobalt and Copper. NTC thermistors are semiconductor resistors that exhibit decreasing resistance characteristics with increasing temperature. Temco thermistors have low thermal time constants which result in extremely high rates of resistance change to accurately track the temperature. Typical Features: - Quick response to temperature change - Small dimensions - High stability over a long life - Resistant against vibration and temperature shocks - Resistant to corrosive atmospheres and harsh environments - simple interchangeability - high reliability Applications: - Temperature measurement control - Automotive systems - Industrial process control RTS-Raw 10K NTC Thermistor Specifications: Rated Resisitance: R25=10.00KΩ±1% B-Value: B25/50=3950Ω±1% OperatingTemperature: -30 ~ +80 C Dimensions (mm): 1: TC39B103F 2: Epoxide Resin, Clear 3: Ø0.5mm Tinned Copper Wire - 1 -
2 RTS-Bead-4: Thermistor bead, 4 (10cm) lead, 10mm wire trimmed and tinned, 0.2DegC accuracy Specifications: Zero Power Resistance: R25=10.00kΩ ±1% B-Value: B25/50=3950K ±1% Operating Temperature Range: -30 ~ +80 C Insulated Resistance: 500VDC in water, >100M Ω Breakdown Voltage: 1500VAC in water, 1 minute. No flash over (Leak Current: 1mA Max). Dimensions (mm): 1: TC39B103F 2: EPOXY RESIN 3: UL /2CAWG 105 C Black Wire TS-10K-0.6SSP-7 Temperature Sensor: 0.6 SS probe temp sensor, 10K thermistor, type 2 Specifications: Nominal Resistance: R25=10.00kΩ±1% B Value: B25/50=3950K±1% Operating Temperature Range: -30 ~ +80 C Insulated Resistance: 500VDC in water, >100MΩ Breakdown Voltage: 1500VAC, 1min. Dimensions (mm): 1: TC39B103F 2: Ø5x15 Stainless Steel 3: UL /2CAWG 105 C Black Wire - 2 -
3 WTS : 25mm(1 ) 304 stainless steel probe, 300mm(12 ) long 22ga standard cable, 10K, type 2 Specifications: Nominal Resistance: R25=10.00kΩ±1% B Value: B25/50=3950K±1% Operating Temperature Range: 30 ~ +105 C Insulated Resistance: 500VDC in water, >100MΩ Breakdown Voltage: 1500VAC, 1min. Dimensions (mm): 1: TC39B103F 2: Ø6x25 Stainless Steel 3: Epoxide Resin 4: UL AWG/2C 105 C Black Wire OAT3000 Temperature Sensor Specifications: Nominal Resistance: R25=10.00kΩ±1% B Value: B25/50=3950K±1% Operating Temperature Range: 0 ~ +50 C Insulated Resistance: 500VDC in water, >100MΩ Breakdown Voltage: 1500VAC, 1min. Dimensions (mm): 1: TC39B103F 2: Ø6 83mm Stainless Steel Enclosure 3: AVVR 2 0.2mm 2, 105 C black tube 4: Ø4.5mm Black,125 C, Heat-shrink tube - 3 -
4 Duct Sensor Applications The duct sensor is used to measure the supply and return air temperature in HVAC systems. There are several sensor element ranges to choose from, which guarantee compatibility with all popular DDC systems. The sensor elements are precision thermistors or platinum RTDs. Field calibration is not generally required. The probe is epoxy sealed to prevent moisture from migrating into the probe. The standard probe length is 12 inch. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastic & metal manufacturing capabilities for custom housings as well. Plastic Water Resistant Box: Plastic Box for 1/2 EMT Connection: Electrical Box: Features Sensor Property Specification Thermistor Accuracy +/- 0.2 C Platinum RTD Accuracy +/- 0.4 C Thermistor Range -70 C to 150 C Platinum RTD Range -200 C to 300 C Probe Material Stainless Steel Cable Properties FT4, 80 C, 600V - 4 -
5 Construction The sensor is a high quality unit manufactured to industrial standards. The probe is made from stainless steel with a welded and ground tip, not a separate welded plug as some other probes in the HVAC industry. The probe is baked and then epoxy sealed to eliminate long term moisture problems. Installation Insert the probe well into the air stream in an area with no stratification or local thermal effects. A supply air sensor is located at any convenient location two or three meters down stream from the nearest fan and coil. A return air sensor can be mounted anywhere in the return duct, one meter or two before the mixing section usually. To install the sensor, drill a 3/4 hole in the duct and insert the probe into the airstream. Secure the electrical box to the duct with two sheet metal screws. The knockouts on the electrical box accept a 1/2 pipe or flex connector. The sensor requires two conductors, normally 18ga unshielded twisted pair. Dimensions (mm) Ordering Information - 5 -
6 RTS Room Temperature Sensor Descriptions The sensor provides precision room temperature sensing for Energy Management Control Systems. There are several RTD and thermistor models in several ranges for compatibility with all popular DDC systems. Low drift and long term accuracy is assured, field calibration is not generally required. The enclosure design allows for use in areas where appearance is important. The sensors saves I/O space on the DDC controller by connecting to a single input. User button activity is captured in the DDC system application programs as high and low going pulses, providing full software control of the button actions. Features Sensor Property Specification Thermistor Accuracy +/- 0.2 C Platinum RTD Accuracy +/- 0.4 C Thermistor Range -70 C to 150 C Platinum RTD Range -200 C to 300 C Calibration The RTS uses precision thermistors, so calibration is optional. The sensor routes the thermistor signal directly to the DDC controller, and also to an on board 8 bit A/D converter for local display of the temperature. This A/D converter and associated circuitry can be calibrated by adjusting a potentiometer on the sensor. The potentiometer affects only the local display, not the thermistor signal at the DDC controller. Installation The unit is located on an interior wall, away from windows, supply ducts and heat sources. The enclosure can be mounted flush on the wall, or on an electrical box. The backplate has holes for North American and European style electrical boxes. The RTS requires two conductors. The removable terminal block on the back of the RTS can accept wires up to 18 gauge, while the RTS requires butt connectors. Two allen key screws on the bottom of the enclosure backplate are screwed inwards to allow the cover to be removed and outwards to hold the cover in place
7 RTS3 Flush Mount Room Temperature Sensor Descriptions This sensor provides precision room temperature sensing for Energy Management Control Systems, compatible with all the leading controls systems. It is a 10K Thermistor and can be used with many popular brands of DDC manufacturers. Low drift and long term accuracy is assured, field calibration is not generally required. The sensor saves I/O space on the DDC controller by connecting to a single input. User button activity is captured in the DDC system application programs as high and low going pulses, providing full software control of the button actions. Dimensions Installation The enclosure design allows for use in areas where appearance is important. This Flush Mount temperature sensor can be screwed directly into the dry wall and painted over to become almost invisible to the occupant
8 DTS-FL Temperature Sensor Descriptions This sensor is used to measure duct supply and return temperatures in HVAC systems. The flange mount design makes it easy to install the sensor in tight quarters. There are several RTD and thermistor models in several ranges for compatibility with all popular DDC systems. The standard probe length is 9in with plenum rated cable of 10ft (3m). Low drift and long term accuracy is assured, field calibration is not generally required. Specifications Sensor Property Specification Thermistor Accuracy +/-0.2 C Platinum RTD Accuracy +/-0.4 C Thermistor range -70 C to 150 C Platinum RTD range -200 C to 300 C Probe Material Stainless Steel Cable Properties FT6, ULC S C, 600V Construction The sensor is a high quality unit manufactured to industrial standards. The probe is made from 314 stainless steel with a welded and ground tip, not a separate welded plug as some probes in the HVAC industry. The probe is baked and then epoxy sealed to eliminate long term moisture problems.the flange accepts two #6 screws, and is made from 314 stainless steel as well. Installation Duct probes should be installed directly on the duct, in an area where the airsteam is well mixed: Locate a supply air sensor two or three meters down stream from the nearest fan-coil. A return temperature sensor can be mounted anywhere in the return duct, after the return fan if there is one. To install the sensor, drill a 3/4 hole in the duct and insert the probe into the airstream. Secure the metal flange to the duct with two sheet metal screws. The plenum rated cable is secured to the duct to the nearest electrical box. The sensor requires two conductors, normally 18ga unshielded twisted pair. Ordering Information - 8 -
9 OAT Outside Air Temperature Sensor Descriptions This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start / stop, and supply temperature reset. The housing is made from PVC electrical fittings which shield the probe from direct sunlight. There are several RTD and thermistor models in several ranges for compatibility with all popular DDC systems. Low drift and long term accuracy is assured, field calibration is not generally required. Specifications Sensor Property Specification Thermistor Accuracy +/-0.2 C Platinum RTD Accuracy +/-0.4 C Thermistor Range -70 C to 150 C Platinum RTD Range -200 C to 300 C Probe Material Stainless Steel Cable Properties FT4, 80 C, 600V Construction The sensor is a high quality unit manufactured to industrial standards. The probe is made from 314 stainless steel with a welded and ground tip, not a separate welded plug as some probes in the HVAC industry. The probe is baked and then epoxy sealed to eliminate long term moisture problems. The sensor housing is a PVC electrical enclosure which is UL approved for outdoor use. The housing extends over the probe to protect from sunlight radiation. The sensor lead extends 12 from the enclosure, making it long enough to reach a junction box and terminate inside the building. Installation The OAT sensor can be mounted on the outside of the building using the following guidelines: Choose a spot on the north face which will be out of sunlight for as much of the day as possible. Mount the sensor where it can be serviced, staying away from exhaust ducts. Point the probe downwards to avoid catching rain. To install the sensor, drill a 3/4 (20mm) hole through the wall, and pipe the sensor to an electrical junction box on the inside of the wall. The sensor has a female 1/2 NPT threaded fitting to accept a short length of 1/2 pipe or PVC. The sensor requires two conductors, normally 18ga unshielded twisted pair
10 RTS1 Room Temperature Sensor Descriptions The RTS1 Room Temperature Sensor is designed for use with building automationsystems in commercial buildin gs,hospitals,museums or other facilities requiring accurate measurement of relative temperature. Each transmitter utilizes a capacitive polymer sensor to provide excellent linearity and sensitivity. In addition the model RTS1 is available with a built-in thermistor which can be used to measure both room temperature and relative temperature. This unit can be directly mounted to a drywall partition, or vertically to a 2 x 4 electrical handy box using the optional adaptor plate(rhs PLATE). Specifications Supply Voltage to 15 VDC Input Power ma Output Range... 0 to 100% RH Sensing Accuracy... +/-3% over 10% to 90%RH Output Signal... 0 to 5 VDC R Load ohm Max. Operating Temperatuer Range...4 to 49 C Housing Wire Size...14 to 22Awg (Recommended) Thermistor (RTS1 Only)...10k ohms at 25 C Dimensions H x 2.0 W x 0.2 D Weight Oz Adaptor Plate Dimensions L x 2.75 W
11 WTS Water Temperature Sensor Descriptions This sensor is used to measure water temperature of heated or chilled water and other liquids in mechanical systems. It includes a brass well which allows the probe to be removed from the pipe without draining the system and protects the probe. There are several RTD and thermistor models in several ranges for compatibility with all popular DDC systems. Low drift and long term accuracy is assured, field calibration is not generally required. WTS-MO: WTS-WP: WTS-M1: WTS-P: Wells: Specifications Sensor Property Specification Thermistor Accuracy +/-0.2 C Platinum RTD Accuracy +/-0.6 C Thermistor Range -70 C to 150 C Platinum RTD Range -200 C to 300 C Probe Material Stainless Steel Cable Properties FT4, 80 C, 600V Construction The probe is made from stainless steel with a welded and ground tip, not a separate welded plug as some probes in the HVAC industry. The probe is baked and then epoxy sealed to eliminate long term moisture problems. The probe is spring loaded to ensure thermal contact with the bottom of the well. The well is made from machined brass, and fits a standard 1/2 NPT fitting. The sensor housing is a galvanized electrical box. Installation Locate water temperature sensor at least a few pipe diameters downstream any heat or cooling source: A 1/2 NPT female pipe fitting is welded into the pipe. These fittings are usually supplied and installed by the piping trade under direction of the controls trade. Choose an orientation where any condensation will not collect, such as the top of a horizontal pipe section or at a 45deg angle from horizon. Before threading the sensor into the well, deposit some thermal paste in the bottom of the well to improve heat conduction between the metal parts. The sensor is wired with two conductors, normally 18ga unshielded twisted pair
12 Dimensions 2 Well 4 Well
13 6 Well 8 Well Probes:
14 1/2 NPT Stainless Steel Flange:
15 WTS5 Water Temperature Sensor Descriptions This sensor is used to measure water temperature of heated or chilled water and other liquids found in the various mechanical systems of a building. It is especially intended for strapping to the outside of a pipe when there is no oppportunity to install a well such as in a retro-fit or additions to an existing system. The strap on probe is also useful in applications such as monitoring batteries, transformers, generators, and generally any place where a complete assembly cannot be mounted. Ice rink slabs and soil temperature are other applications. There are several RTD and thermistor models in several ranges for compatibility with all popular DDC systems. Low drift and long term accuracy is assured, field calibration is not generally required. Specifications Sensor Property Specification Thermistor Accuracy +/-0.2 C Platinum RTD Accuracy +/-0.6 C Thermistor Range -70 C to 150 C Platinum RTD Range -200 C to 300 C Probe Material Stainless Steel Cable Properties FT4, 80 C, 600V Construction The probe is made from 314 stainless steel with a welded and ground tip, baked and then epoxy sealed to eliminate long term moisture problems. The cable is 12 inch long and fire rated to FT4, 80 C with 600V isolation. A nickel coated spring provides strain relief for the cable. The sensor housing is a galvanized electrical box which is sturdy and easy to mount. Installation For measuring water temperature, the probe is strapped with plastic tie wraps or a metal strap onto the outside of the pipe and covered with insulation. The electrical box is mounted on a strut bar or on the wall near the pipe. Two conductors are required, 18ga unshielded twitted pair is common
16 Wells Descriptions These thermowells are designed for mounting temperature sensors in pipes and tanks. The thermowells are designed to reduce the stress encounted in flowing fluid installation which produces a constantly oscillating force that can eventually crack a probe unless it is mounted in one of these wells. The wells are designed to handle this stress yet provide good thermal contact with the fluid. They also provide isolation, if the sensor needs to be serviced the system can remain in operation without having to drain down the lines. Features & Options Three Lengths: 2, 4 and 8 (Fit standard Immersion Unit lengths) Stainless Steel (304 or 316) or Brass Two Part (Welded) or Machined Construction Other Lengths or Materials Available Upon Request Limited Lifetime Warranty 2 Part (Welded) Temco well Standard Temco wells available from Temco include 304 stainless steel (machined), 316 stainless steel (machined), brass (machined), and two part (welded) stainless steel. These wells are offered in 2,4 and 8 lengths with 1/2 NPT external and 1/2 NPSM. Other lengths and thread diameters are available upon request.the Thermowell chosen for the installation is governed mainly by the corrosion conditions the well will face. The machined stainless steel wells all come with a mirror polish to provide maximum corrosion resistance. Occasionally, the material consideration is one of strength rather than corrosion. For example, a machined stainless steel well may be required for high pressure water service where otherwise a brass or two part stainless steel well would be satisfactory from a corrosion standpoint. market requirement. Well failures, in most cases, are not due to the effects of pressure or temperature on the well. The calculations necessary to provide adequate strength, under given conditions, are familiar enough to permit proper choice of wall thickness and material. The values shown in Table 1 are conservative, and intended primarily as a guide. Wells are also safe if the resonant frequency is well below the wake frequency or if the fluid velocity is constantly fluctuating through the critical velocity point. Nevertheless, if the installation is not hampered by the use of a sufficiently stiff well
17 Dimensions
18 Temperature Curves Part # -> DegC 3K -6 Thermister Type, Ohms / Part Number Suffix 10K Type2-7 10K Type K K , , , ,000 4,067, , , , ,600 2,890, , , , ,600 2,077, , , , ,000 1,508, ,092 96,974 78, ,600 1,106, ,868 72,895 63, , , ,589 55,298 47, , , ,694 42,314 38,515 92, , ,795 32,650 29,490 70, ,017 1, ,618 25,395 23,460 53, ,041 1, ,971 19,903 18,790 41, ,807 1, ,714 15,714 15,130 32, ,702 1, ,748 12,493 12,260 25, ,729 1, ,000 10,000 10,000 20, ,000 1, ,416 8,056 8,194 15,884 79,428 1, ,959 6,530 6,752 12,696 63,489 1, ,597 5,324 5,592 10,210 51,058 1, ,310 4,366 4,655 8,258 41,301 1, ,080 3,601 3,893 6,718 33,598 1, ,985 3,327 5,494 27,479 1, ,487 2,760 4,518 22,593 1, ,082 2,375 3,734 18,669 1, ,751 1,990 3,100 15, ,480 1,724 2,586 12,932 1, ,256 1,458 2,186 10, ,070 1,271 1,824 9,121 1, ,084 1,542 7,709 1, ,308 6,542 1, ,114 5, ,767 1, , ,525 1, ,046 1,460 1K RTD
Temperature Sensors. Description. Specification
Description Temperature sensors are used to measuring the temperature for the air conditioning industry. This document shows the enclosures and temperature vs. resistance curves for the standard sensors.
More informationImmersion Temperature Sensors
Overview The Immersion Temperature Sensor is made for thermowell mounting and temperature measurement in water pipes, water tanks or cooling tower sump applications. The rigid probe is made of Stainless
More informationAndover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air
Infinity Duct & Immersion Temperature Sensors Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air temperature and fluid as part of an Andover Controls building automation
More informationTE-6300 Series Temperature Sensors
TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued July 14, 2008 Supersedes November 13, 2006 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety
More informationTS Series TS Series
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com TS-6700-850 Series TS-5700-850 Series Electronic Remote Temperature Sensors General Instructions APPLICATION Electronic thermistor
More informationTE-6300 Series Temperature Sensors
TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued April 7, 2010 Supersedes March 13, 2009 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety
More informationTS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs
TS-63000 Temperature Sensor and Transducers Product Bulletin The TS-6300 series temperature sensors provide an active and passive signal that corresponds to the air or water temperature in heating, ventilating
More informationTE-6300 Series Temperature Sensors Catalog Page
Code No. LIT-1900217 Issued February 2017 TE-6300 Series Temperature Sensors Catalog Page Description The TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature
More informationBAPI-Stat 3 Room Sensor
Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read
More informationBarbara, Here is the list of items. I numbered the attachments to match with the numbers below.
From: Dan Wilson [mailto: DWilson@wilsonengineerinciservices.com] Sent: Thursday, April 09, 2015 5:10 PM To: Bernstein, Barbara Subject: RE: checking... Barbara, Here is the list of items. I numbered the
More informationBAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)
Overview The BAPI-Stat 4 Style room unit is available as a humidity only sensor or as a combination temperature and humidity sensor with optional LCD display, temperature setpoint adjustment and occupant
More informationAD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation
592 Theory of Operation The 592 sensor is a two terminal integrated-circuit temperature sensor. The 592 provides an output current directly proportional to absolute temperature. When the temperature of
More informationGeneral Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG
More informationSubmersible Averaging Duct Transmitters BA/T#SA Temperature Transmitter Installation & Operations
Overview The BA/#-SA is for duct mounting 4 to 20mA or Voltage temperature transmitter for measurement of moisture saturated, stratified air across a duct with a humidifier or outside air intake to give
More informationUser's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator
User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator Table of Contents Page Introduction... 1 Description... 1 Specifications... 2 Installation... 3 Calibration... 4 General Maintenance...
More informationMGL Avionics EFIS G2 and iefis
MGL Avionics EFIS G2 and iefis Guide to using the MGL RDAC CAN interface with the LAD AERO Injection Kit on ROTAX 912-912S General... 3 Data connections... 3 LAD AERO ROTAX 912 engine data from ECU...
More informationTS , -850 Series TS , -850 Series TS-57031, TS
TS-5711-770, -850 Series TS-57011-770, -850 Series TS-57031, TS-57031-850 Electronic Room Temperature Sensors General Instructions Application These sensors provide electronic sensing of room temperature
More informationC7170A,B Encapsulated Temperature Sensor
C7170A,B Encapsulated Temperature Sensor The C7170A,B Temperature Sensors are for use with electronic controllers where linear PTC sensors are required (W7100, W7600, W7620, or Excel 500, for example),
More informationMS Application. Features. Proportional Valve Actuator General Instructions
Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and
More informationDuct Averaging Transmitters BA/T#-A Temperature Transmitter Installation & Operations
Overview The BA/T#-A is a flexible averaging duct mounted 4-20mA or Voltage transmitter probe. It comes in a variety of probe lengths and optional mounting enclosures shown below. The 4-20mA transmitter
More informationInstallation and Operation Instructions DLP Series
Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW
More informationDuct Temperature Sensors
Duct s Model TE-701 / 702 More than 15 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTD s are available for universal compatibility. Five installation options probe with
More informationTEMPERATURE SENSOR ASSEMBLIES (PROBE)
Discription: TEMPERATURE SENSORS A temperature sensor is an element that sensed the temperature changes, then translate the measured temperature into an electrical signal which then providing the data
More informationSEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399
DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is
More informationThermowells Explained Application Notes
Thermowells are hidden in pipes and are rarely seen. How dimensions are established for the wells and the immersion probes that fit into them are not readily apparent. This application note exposes how
More informationLTX RF LEVEL SENSOR. Instruction Manual
LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004
More informationNTC Thermistor Assemblies
FEATURES Standard and custom assemblies are available in a variety of configurations Assemblies can conveniently attach to or be an integral part of any system to monitor or control temperature No added
More informationTEMPERATURE SENSORS TEMPERATURE SENSORS
TEMPERATURE SENSORS TE Connectivity is a leader in the design and manufacture of NTC thermistors, RTDs, thermocouples, thermopiles, digital output and customized sensor assemblies. Building on our long
More informationThank you! First in Sensor Quality. Twice awarded Wisconsin Manufacturer of the Year. Table of Contents
Table of Contents Displays A/LCD (4-20mA Input) -LCD (Display Add-on for Temperature Sensors) A/TUC (Microprocessor Temperature) A/TUCH (Microprocessor Temperature / RH) DI-1 DI- 3 DI-5 DI-7 Temperature
More informationTemperature Transmitters
Termination BAPI recommends using twisted pair of at least 22AWG and sealant filled connectors for all wire connections. Larger gauge wire may be required for long runs. All wiring must comply with the
More informationSECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:
SECTION 15970 HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Thermostats, temperature transmitters, controllers, automatic valves, dampers, damper operators, pneumatic/ electric
More informationThermistor Temperature Sensor Range
smart Main Features ontrols Temperature Sensors for all common applications Data Sheet S1 Temperature Sensors with Thermistor Elements Close tolerance Thermistor Elements (+/- 0.2 accuracy within range
More informationFigure 1: WPR2 Dimensions and Hardware
Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware
More informationRA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System
RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System Product Bulletin Code No. LIT-12011620 Issued July 2, 2014 RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow Measuring System averages
More informationSanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics
THORNTON Leading Pure Water Analytics Sanitary Sensors Sanitary Sensors Temperature Sensors 3A Sanitary Turbine Flow Sensors Pressure Sensors Tank Level Sensors High Quality, Precision Sanitary Sensors
More informationArticle on Sheath materials, Thermowells, Fittings, and Terminations
Article on Sheath materials, Thermowells, Fittings, and Terminations 1. INTRODUCTION Temperature sensor element for laboratory and industrial use should normally be protected by some form of sheath or
More informationHUMIDITY / TEMPERATURE TRANSMITTER
HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY
More informationA91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing
A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing Installation Sheets Manual 121 Temperature Controls Section A Technical Bulletin A91 Issue Date 0179 Application These thermistor
More informationGold Series Thermal Dispersion Airflow Measurement Technology. Advantage. Installation, Operation and Maintenance Technical Manual GF1
Thermal Dispersion Airflow Measurement Model GF1 Technical Manual Gold Series Thermal Dispersion Airflow Measurement Technology Advantage Gold Series by Ebtron Installation, Operation and Maintenance Technical
More informationDuct Temperature Sensors. Model TE-701 / 702
Duct s Model TE-701 / 702 More than 12 types of interchangeable NTC s, precision platinum, nickel or balco s are available for universal compatibility. Five installation options probe with mounting flange
More informationSLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS
SLC-811X Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Single Loop Proportional Temperature Controller General Instructions APPLICATION Electronic temperature controller
More informationMP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MP-5400 Series Electronic Positive Positioning Hydraulic Actuator General Instructions Application The MP-5400 Series Actuators
More informationGE Measurement & Control
GE Measurement & Control Telaire Ventostat 8000 Series CO 2 Sensor User Instructions Installing the Sensor!WARNING! Before performing service or maintenance operations on the systems, turn OFF main power
More informationAD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure
592 Theory of Operation The 592 sensor is a two terminal integrated-circuit temperature sensor. The 592 provides an output current directly proportional to absolute temperature. When the temperature of
More informationSEN and SEN Outdoor Air Temperature Sensors
FANs 216, 1628.3 Product/Technical Bulletin SEN-500-2, SEN-500-3 Issue Date 0996 SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors The SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors offer
More informationPipe Temperature Sensors. Model TE-703 / 704
Pipe Temperature Sensors Model TE-703 / 704 Four immersion thermowell installation options brass adapter with 304SS probe for adjustable insertion, plastic, galvanized steel or NEMA-4/IP-65 steel enclosure.
More informationMount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)
EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp
More informationHot Tap Insertion Vortex
Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design
More informationDuct thermometer Model TF40
Electrical temperature measurement Duct thermometer Model TF40 WIKA data sheet TE 67.16 Applications Air-conditioning technology Ventilation technology Refrigeration technology Heating technology Special
More informationSanitary RTDs and Temperature Transmitters
SENSORS FOR FOOD AND LIFE SCIENCES. Product Information - SA/CT FOOD Sanitary RTDs and Temperature Transmitters Introduction Anderson-Negele s electronic temperature sensors combine our industry proven,
More informationFoxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element
Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationW91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer
Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY
More informationCAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*
CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationSECTION INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
PART 1 GENERAL 1.01 SECTION INCLUDES A. Air supply system. B. Thermostats. C. Humidistats. D. Control valves. E. Automatic dampers. F. Damper operators. G. Miscellaneous accessories. 1.02 RELATED REQUIREMENTS
More informationWhat are RTD Sensors? Why Use Them? How Do They Work?
What are RTD Sensors? Why Use Them? How Do They Work? What is an RTD? Resistance Temperature Detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature
More informationPPT 802, Proximity Probe Transducer System
PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current
More informationTechnical Information Omnigrad TST90, TET90
TI01109T/09/EN/02.13 71214205 Products Solutions Services Technical Information Resistance thermometer and insert for thermal energy measurement High-precision measurement of temperature differences with
More informationInstallation/ Operation Maintenance. VariTrac Dampers
Installation/ Operation Maintenance VariTrac Dampers June 2002 General These instructions do not cover all variations in systems nor provide for every possible contingency that may arise at a jobsite installation.
More informationOPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)
MOEL COE UCT SHAPE = Round = Rectangular = Flat Oval PROBE MATERIAL = Aluminum/ABS = CPVC & ABS = 0SS = High Temp SS (50 F / C Max) PROBE QUANTITY = = s = s = s SENSORS PER PROBE = Sensor per = Sensors
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationSanitary RTDs and Temperature Transmitters
Sanitary RTDs and Temperature Transmitters Modular components provide maximum configuration flexibility Unique element-to-housing design eliminates exposed threads, lowers profile All stainless steel construction
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18
Zone Sensors Submittal Data English Language/IP Units SD1582EW 06/18 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More informationBAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint
Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication
More informationFeatures Globe Valve 2-Way & 3-Way Assembly Features:
Rev: 10/22/13 Features Globe Valve 2-Way & 3-Way Assembly Features: DG Series Automated Applications for Building Automation, Temperature Controls, HVAC Two-Way and Three-Way Assemblies Chilled Water Hot
More informationCO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure
Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to
More informationACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:
ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,
More informationNTC Thermistors. Vishay FEATURES. Custom designed executions Application specific leads, housings, and connectors. NTC Thermistors Screw terminal
Custom designed executions Application specific leads, housings, and connectors TOLERANCE AT R25 C RANGE OPERATING TEMPERATURE RANGE APPLICATIONS Screw terminal 2322 640 73 5% 100 to 470k -25 to +100 C
More informationCO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration
Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to
More informationDWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/
Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16
More informationDigital Room Thermostats with Touch Screen LCD
TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),
More informationTEMPERATURE REGULATORS W91/W94 Series
Self-Operated Temperature Regulators Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company Self-Operating Design Indicating
More informationC7046A,B,C,D Air Temperature Sensors
C7046A,B,C,D Air Temperature Sensors FEATURES PRODUCT DATA APPLICATION The C7046 series of Air Temperature Sensors function as primary and/or secondary sensors in electronic control systems. C7046A,C Sensors
More informationSTRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
More informationPaddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual
COMPANY Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual Mechanical Specifications Flow Meter with Polypropylene Body (ES version) Maximum Operating Pressure: 150 PSIG Maximum
More informationARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82
E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General
More informationThermocouples W A T L O W
W A T L O W Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions of thermocouples for
More informationSECTION FLOW INSTRUMENTS
SECTION 230923.14 FLOW INSTRUMENTS Data contained in this guide specification may be placed in either of the following sections, depending on the specifics of the system design, or incorporated within
More informationChapter Page. 1 Introduction Description 1
Chapter Page 1 Introduction 1 1.1 Description 1 Table of Contents 2 Calibration 3 2.1 Wet Calibration 3 2.2 Calibration Procedure 4 2.3 Installing Optional Display Board 5 2.4 Display Board Range Adjustment
More informationModels beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.
Models beginning with MO, MK, 7B, 6S, 6F or 5B The Mini Meter Product Description Technical Specifications Installation Instructions February 28 th, 2013 1. Product Description...2 1.1 General Description...2
More informationHydro-Flow 2200 Fixed Insertion Vortex Flow Meter
A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,
More information37T Series Moisture Resistant Temperature Controls
37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a
More informationPaddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual
COMPANY Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:PADDLEMAN082416 Mechanical Specifications Flow Meter with Polypropylene
More informationATP-2040 Electric Damper Actuator/Transmitter
ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential
More informationQVT MULTIVARIABLE TRANSMITTER
QVT MULTIVARIABLE TRANSMITTER QVT INSTALLATION & OPERATION MANUAL REV 8/16 REVISION VERSION 0.3.4 ORIGINAL LANGUAGE Copyright 2016 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE OF CONTENTS
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14
Zone Sensors Submittal Data English Language/IP Units SD1582EW 10/14 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More information22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER
UHC 300 22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER OVERVIEW The HVAC building automation controls market requires a DDC controller that provides scalable, consolidated control in a fully programmable,
More informationNC State University Design and Construction Guidelines Division 23 Energy Management
1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have
More informationEX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.
E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General
More informationTX101/201 Insertion Turbine Instructions
TX101/201 Insertion Turbine Instructions General Information Sapphire bearings and a non-drag pick-off give these adjustable insertion turbine flow sensors a wide flow and long life. A Hall-effect device
More informationSilver Series Thermal Dispersion Airflow Measurement Technology
Thermal Dispersion Airflow Measurement Model STx104-U Unit Ventilator Airflow Measurement System Technical Data Silver Series Thermal Dispersion Airflow Measurement Technology APPLICATIONS Direct outdoor
More informationVG7000 Series Bronze Control Valves
FANs 977, 125, 1628.3 Product/Technical Bulletin VG7000 Issue Date 0301 VG7000 Series Bronze Control Valves VG7000 Series Bronze Control Valves are designed primarily to regulate the flow of water and
More informationCONTROLLERS & SPECIAL VALVES
CONTROLLERS & SPECIAL VALVES G75-C 1, 2 & 4 Valve Controllers.... 70 G75-C-1W & 1W+ Window Controller... 72 G75-DP Differential Pressure Switch.....................................................................
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored Variable Frequency
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths
More informationBAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control
Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and pushbutton setpoint adjustment. Additional options include pushbutton override, fan
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal
More informationSTRATO LED Drivers Metal Enclosure 35W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
More informationMP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MP-5200 Series Electronic Hydraulic Actuator General Instructions Application The MP-5200 Series actuators are for the electronic
More information