2 WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable and energy efficient. 120/240 Volts 3 Watt Floor Heating Cable System Easy Installation Emits Zero EMF 25 Year Limited warranty Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Ambient Temp. Min. Installation Temp. Cold Lead Length Model 3CWC 120V 10 3CWC 120V 15 3CWC 120V 20 3CWC 120V 25 3CWC 120V 30 3CWC 120V 35 3CWC 120V 40 3CWC 120V 45 3CWC 120V 50 3CWC 120V 60 3CWC 120V 70 3CWC 120V 80 3CWC 120V 90 3CWC 120V 100 3CWC 120V 110 3CWC 120V 120 3CWC 120V 130 3CWC 120V 140 ohms 3CWC 120V 150 watt amp 120 Volts Length Twin Conductor 120V / 240V 3W/ft (9.84W/m) 40' (12.2m) to 1200' (365.8m) 1" (25.4mm) 1/8" 1/5" (3.3mm 5.0mm) Fluoropolymer Fluoropolymer,TPE or Nylon 85 (30 ) 40 (5 ) 2 Wire 16 AWG Plus Ground Braid 10 ft. (3m) Thickness Covers / SqFt Spacing Ft (mm) 2" 3" 4" , ,5 60 3, , , , , , , , , , , , , , , , , , , , ,
3 WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient. 120/240 Volts 3 Watt Floor Heating Cable System Approved For Showers Durable Construction Single Point Connection 25 Year Limited warranty 240 Volts Covers / SqFt Length Thickness Model ohms watt amp Spacing Ft (mm) 2" 3" 4" 3CWC 240V ,5 40 3, CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , , CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , , CWC 240V , , CWC 240V 70 68, , CWC 240V , , CWC 240V 90 53, , , CWC 240V , CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , CWC 240V , CWC 240V , CWC 240V , , CWC 240V , CWC 240V
4 WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable Structure Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient. 120/240 Volts 3 Watt Floor Heating Cable Structure Approved For Showers Durable Construction Single Point Connection 25 Year Limited warranty Cable diameter mm 120 Volts from 10 Sq.Ft. to 80 Sq.Ft. 240 Volts from 10 Sq.Ft. to 160 Sq.Ft. Cable diameter mm 120 Volts from 90 Sq.Ft. to 150 Sq.Ft. 240 Volts from 180 Sq.Ft. to 300 Sq.Ft.
5 WA-3.7CWC 3.7 Watt Floor Heating Cable System For Uncoupling Membrane 3.7 Watt Floor Heating Cable System For Uncoupling Membrane Warm Cable floor heating system for uncoupling membrane combines the highest comfort levels with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient. Easy Installation Emits Zero EMF 25 Year Limited warranty Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Ambient Temp. Min. Installation Temp. Cold Lead Length Model ohms watt amp 120 Volts Length Twin Conductor 120V / 240V 3.7W/ft (12.14W/m) 16.5' (5m) to 990' (301.75m) 1" (25.4mm) 1/5" (4.9mm) Fluoropolymer PVC 85 (30 ) 40 (5 ) 2 Wire 16 AWG Plus Ground Braid 10 ft (3m) Length Covers SqFt Spacing Ft M 3,5" 3,75" 3,7CWC 120V ,5 16,5 5,05 4,8 5,2 3,7CWC 120V ,1 9,6 10,3 3,7CWC 120V ,5 49,5 15,1 14,4 15,5 3,7CWC 120V ,1 19,3 20,6 3,7CWC 120V ,5 82,5 25,1 24,1 25,8 3,7CWC 120V ,2 28,9 30,9 3,7CWC 120V 34 32, ,5 115,5 35,2 33,7 36,1 3,7CWC 120V ,2 38,5 41,3 3,7CWC 120V 43 26, ,5 148,5 45,3 43,3 46,4 3,7CWC 120V ,3 48,1 51,6 3,7CWC 120V ,4 57,8 61,9 3,7CWC 120V 67 17, ,4 67,4 72,2 3,7CWC 120V , ,5 3,7CWC 120V 87 13, ,5 86,6 92,8 3,7CWC 120V ,6 96,3 103,1 3,7CWC 120V , ,6 105,9 113,4 3,7CWC 120V ,7 115,5 123,8 3,7CWC 120V 125 9, ,8 125,1 134,1 3,7CWC 120V 135 8, ,8 134,8 144,4 3,7CWC 120V ,9 144,4 154,7 Saint Basile Le Grand, Quebec,J3N 1A1
6 WA-3.7CWC Floor Heating Cable System For Uncoupling Membrane Floor Heating Cable System For Uncoupling Membrane Easy Installation Emits Zero EMF 25 Year Limited warranty 240 Volts Model ohms watt amp Length Length Covers SqFt Spacing Ft M 3,5" 3,75" 3,7CWC 240V , ,1 9,6 10,3 3,7CWC 240V ,8 49,5 15,1 14,4 15,5 3,7CWC 240V ,1 19,3 20,6 3,7CWC 240V ,3 82,5 25,1 24,1 25,8 3,7CWC 240V , ,2 28,9 30,9 3,7CWC 240V , ,8 115,5 35,2 33,7 36,1 3,7CWC 240V ,2 38,5 41,3 3,7CWC 240V , ,3 148,5 45,3 43,3 46,4 3,7CWC 240V , ,2 48,1 51,6 3,7CWC 240V ,4 57,8 61,9 3,7CWC 240V 67 68, , ,4 67,4 72,2 3,7CWC 240V , ,5 3,7CWC 240V 87 53, , ,6 86,6 92,8 3,7CWC 240V ,6 96,3 103,1 3,7CWC 240V ,8 115,5 123,8 3,7CWC 240V , ,8 134,8 144,4 3,7CWC 240V ,7CWC 240V , ,3 185,6 3,7CWC 240V ,2 192,5 206,3 3,7CWC 240V , ,2 211,8 226,9 3,7CWC 240V , ,5 3,7CWC 240V , ,6 250,3 268,1 3,7CWC 240V , ,6 269,5 288,8 3,7CWC 240V ,8 288,8 309,4 Saint Basile Le Grand, Quebec,J3N 1A1
7 WA-3.7CWC Floor Heating Cable System For Uncoupling Membrane Floor Heating Cable System For Uncoupling Membrane Easy Installation Emits Zero EMF 25 Year Limited warranty Cable diameter 4.9 mm 120 Volts from 05 Sq.Ft. to 106 Sq.Ft. 240 Volts 10 Sq.Ft. to 212 Sq.Ft. Cable diameter 4.9 mm 120 Volts from 115 Sq.Ft. to 144 Sq.Ft. 240 Volts 231 Sq.Ft. to 289 Sq.Ft. Saint Basile Le Grand, Quebec,J3N 1A1
8 WA-6CTS Thermal Storage Cable 6W Thermal Storage Cable 6W is the ideal solution for interior imbeded concrete slab. Single Point Connection Twin Conductor Cable Silent, Efficient And Safe Emits Zero EMF Easy And Flexible Installation Durable Construction Limited Warranty Thermal Storage Cable 6W Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Rated Temperature Min. Installation Temperature Cold Lead Length Cable Sizes Cat. Num. 6CTS 240V 0240W 6CTS 240V 0344W 6CTS 240V 0515W 6CTS 240V 0683W 6CTS 240V 0852W 6CTS 240V 1026W 6CTS 240V 1226W 6CTS 240V 1395W 6CTS 240V 1735W 6CTS 240V 2072W 6CTS 240V 2410W 6CTS 240V 2756W 6CTS 240V 3097W 6CTS 240V 3470W Twin Conductor 120V / 240V 6W/ft (20W/m) 55' (16.8m) to 680' (207.3m) 1.5" (38mm) 1/4 (6.5mm) Fluoropolymer And XLPE PVC 220 (105 ) 40 (5 ) 10 ft (6m) Length Cable Covers /per/sq.ft. Output Ft M 18W 4" 15W 5" 12W 6" Watts Amps Ohms 40 12,2 13,3 16,7 20, ,0 240, ,3 20,0 25,0 30, ,4 167, ,4 30,0 37,5 45, ,1 111, ,1 38,3 47,9 57, ,8 84, ,2 48,3 60,4 72, ,6 67, ,3 58,3 72,9 87, ,3 56, ,0 70,0 87,5 105, ,1 47, ,2 80,0 100,0 120, ,8 41, ,4 100,0 125,0 150, ,2 33, ,2 118,3 147,9 177, ,6 27, ,5 138,3 172,9 207, ,0 23, ,3 156,7 195,8 235, ,5 20, ,5 176,7 220,8 265, ,9 18, ,4 198,3 247,9 297, ,5 16,6 Saint Basile Le Grand, Quebec,J3N 1A1
9 WA-9CTS Thermal Storage Cable 9W Thermal Storage Cable 9 Watt is the ideal solution for interior imbeded concrete slab. Single Point Connection Twin Conductor Cable Silent, Efficient And Safe Emits Zero EMF Flexible Cable Durable Construction 2 Year Limited Warranty Thermal Storage Cable 9W Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Rated Temperature Min. Installation Temperature Cold Lead Length Cable Sizes Cat. Num. 9CTS 240V 0420W 9CTS 240V 0625W 9CTS 240V 0840W 9CTS 240V 1083W 9CTS 240V 1260W 9CTS 240V 1762W 9CTS 240V 2150W 9CTS 240V 2595W 9CTS 240V 3130W 9CTS 240V 3469W Twin Conductor 120V / 240V 9W/ft (30W/m) 57' (17.4m) to 610' (185.9m) 1.5" (38mm) 1/4 (6.5mm) Fluoropolymer And XLPE PVC 220 (105 ) 40 (5 ) 20 ft (6m) Length Cable Covers /Per/Sq.Ft. Output Ft M 28W 4" 22W 5" 18W 6" Watts Amps Ohms 46 14,0 15,3 19,2 23, ,8 137, ,3 23,3 29,2 35, ,6 92, ,0 30,7 38,3 46, ,5 68, ,1 38,3 47,9 57, ,5 53, ,7 46,7 58,3 70, ,3 45, ,9 63,3 79,2 95, ,3 32, ,2 80,0 100,0 120, ,0 26, ,9 95,0 118,8 142, ,8 22, ,6 110,0 137,5 165, ,6 19, ,3 125,0 156,3 187, ,5 16,6
10 WA-12CSW Safe Walk Cable 12W Safe Walk Cable 12 Watt is the ideal solution for exterior imbeded concrete slab, pavers and asphalt. Single Point Connection Twin Multi Braided Conductor Silent, Efficient And Safe Emits Zero EMF Easy And Flexible Installation Durable Construction 20 Year Limited Warranty Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Rated Temperature Min. Installation Temperature Cold Lead Length Twin Conductor 240V / 208V / 600V 12W/ft (40W/m) 35' (10.7m) to 940' (286.5m) 1.5" (38mm) 1/4 (6.5mm) Fluoropolymer And XLPE PVC 220 (105 ) 40 (5 ) 20 ft (6m) Safe Walk Cable 12W Cable Sizes 208 Volt Cat. Num. 12CSW 208V 0420W 12CSW 208V 0600W 12CSW 208V 0840W 12CSW 208V 1020W 12CSW 208V 1260W 12CSW 208V 1500W 12CSW 208V 1740W 12CSW 208V 1920W 12CSW 208V 2160W 12CSW 208V 2520W 12CSW 208V 2940W 12CSW 208V 3360W 12CSW 208V 3810W 12CSW 208V 4260W 12CSW 208V 4920W 12CSW 208V 5520W Length Cable Covers Per Sq.Ft. Output Ft M 48W 4" 36W 5" 29W 6" Watts Amps Ohms 35 10,7 8,8 11,7 14, ,0 103, ,2 12,5 16,7 20, ,9 72, ,3 17,5 23,3 29, ,0 51, ,9 21,3 28,3 35, ,9 42, ,0 26,3 35,0 43, ,1 34, ,1 31,3 41,7 52, ,2 28, ,2 36,3 48,3 60, ,4 24, ,8 40,0 53,3 66, ,2 22, ,9 45,0 60,0 75, ,4 20, ,0 52,5 70,0 87, ,1 17, ,7 61,3 81,7 102, ,1 14, ,3 70,0 93,3 116, ,2 12, ,5 80,0 106,7 133, ,5 11, ,2 88,8 118,3 147, ,5 10, ,0 102,5 136,7 170, ,7 8, ,2 115,0 153,3 191, ,5 7,8
11 WA-12CSW Safe Walk Cable 12W Safe Walk Cable 12 Watt is the ideal solution for exterior imbeded concrete slab. Watt output of the 240V cable is reduced by 25% when operated at 208V Watt output of the 600V cable is reduced by 35% when operated at 480V Single Point Connection Twin Conductor Cable Silent, Efficient And Safe Emits Zero EMF Easy And Flexible Installation Durable Construction 20 Year Limited Warranty Cable Sizes Safe Walk Cable 12W 240 Volt Cat. Num. 12CSW 240V 0480W 12CSW 240V 0720W 12CSW 240V 0960W 12CSW 240V 1200W 12CSW 240V 1440W 12CSW 240V 1740W 12CSW 240V 1980W 12CSW 240V 2220W 12CSW 240V 2460W 12CSW 240V 2940W 12CSW 240V 3420W 12CSW 240V 3900W 12CSW 240V 4440W 12CSW 240V 4920W 12CSW 240V 5700W 12CSW 240V 6420W 600 Volt Cat. Num. 12CSW 600V 1240W 12CSW 600V 1855W 12CSW 600V 3080W 12CSW 600V 3690W 12CSW 600V 4425W 12CSW 600V 5040W 12CSW 600V 5650W 12CSW 600V 6265W 12CSW 600V 7485W 12CSW 600V 8705W Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 40 12,2 10,0 13,3 16, ,0 120, ,3 15,0 20,0 25, ,0 80, ,4 20,0 26,7 33, ,0 60, ,5 25,0 33,3 41, ,0 48, ,6 30,0 40,0 50, ,0 40, ,2 36,3 48,3 60, ,3 33, ,3 41,3 55,0 68, ,3 29, ,4 46,3 61,7 77, ,3 25, ,5 51,3 68,3 85, ,3 23, ,7 61,3 81,7 102, ,3 19, ,9 71,3 95,0 118, ,3 16, ,1 81,3 108,3 135, ,3 14, ,8 92,5 123,3 154, ,5 13, ,0 102,5 136,7 170, ,5 11, ,8 118,8 158,3 197, ,8 10, ,1 133,8 178,3 222, ,8 9,0 Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watt Amps Ohms ,5 25,0 33,3 41, ,1 290, ,7 37,5 50,0 62, ,1 194, ,2 62,5 83,3 104, ,1 116, ,4 75,0 100,0 125, ,2 97, ,7 90,0 120,0 150, ,4 81, ,5 103,8 138,3 172, ,4 71, ,7 116,3 155,0 193, ,4 63, ,0 128,8 171,7 214, ,4 57, ,5 153,8 205,0 256, ,5 48, ,6 178,5 238,0 297, ,5 41,4
12 WA-12CSW Safe Walk Cable 12W Cable Sizes 277 Volt Cat. Num. 12CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V Volt Cat. Num. 12CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V Volt Cat. Num. 12CSW 480V CSW 480V CSW 480V CSW 480V CSW 480V CSW 480V CSW 480V Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 50,0 15,2 12,5 16,7 20, ,9 145,8 70,0 21,3 17,5 23,3 29, ,1 89,4 95,0 29,0 23,8 31,7 39, ,0 69,3 115,0 35,1 28,8 38,3 47, ,2 53,3 140,0 42,7 35,0 46,7 58, ,1 45,4 170,0 51,8 42,5 56,7 70, ,3 38,5 190,0 57,9 47,5 63,3 79, ,4 33,0 215,0 65,5 53,8 71,7 89, ,4 29,5 240,0 73,2 60,0 80,0 100, ,3 26,9 285,0 86,9 71,3 95,0 118, ,5 22,3 330,0 100,6 82,5 110,0 137, ,5 19,1 375,0 114,3 93,8 125,0 156, ,6 16,7 425,0 129,5 106,3 141,7 177, ,6 14,9 475,0 144,8 118,8 158,3 197, ,8 13,3 545,0 166,1 136,3 181,7 227, ,9 11,7 Length Cable Covers Per Sq.Ft. Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 60,0 18,3 4,6 6,1 7, ,1 167,2 90,0 27,4 6,9 9,1 11, ,1 112,5 115,0 35,1 8,8 11,7 14, ,1 84,5 145,0 44,2 11,0 14,7 18, ,1 67,7 175,0 53,3 13,3 17,8 22, ,2 56,4 210,0 64,0 16,0 21,3 26, ,4 47,0 240,0 73,2 18,3 24,4 30, ,4 41,3 300,0 91,4 22,9 30,5 38, ,4 33,2 355,0 108,2 27,1 36,1 45, ,5 27,8 415,0 126,5 31,6 42,2 52, ,5 23,9 470,0 143,3 35,8 47,8 59, ,6 20,9 530,0 161,5 40,4 53,8 67, ,6 18,6 595,0 181,4 45,3 60,5 75, ,9 16,6 680,0 207,3 51,8 69,1 86, ,9 14,5 Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 80,0 24,4 20,0 26,7 33, ,1 232,0 200,0 61,0 50,0 66,7 83, ,1 93,5 330,0 100,6 82,5 110,0 137, ,4 57,1 490,0 149,4 122,5 163,3 204, ,5 38,5 735,0 224,0 183,8 245,0 306, ,6 25,7 820,0 249,9 205,0 273,3 341, ,9 23,0 940,0 286,5 235,0 313,3 391, ,9 20,1
13 WA-RDFP Electric Roof De-Icing Cable WA RDFP roof and gutter de icing help and prevents costly ice damage by preventing ice dam formation and promoting the free flow of water through gutters and downspouts to groung level. Available From 20 to 240 Feet Prevents roof and damage and leaking Keeps Gutter And Downspout Flowing Pre Assemble, Ready To Install 6 Ft 18/3 Cold Lead With Plug Limited Warranty Of 2 Years Electric Roof De-Icing Cable Cable Construction: Rayed Voltage: Output: Heating Element Size: Bending Radius Conductor Insulation: Outer Insulation: Min. Installation Temp.: Cold Lead: Other Cat. Num. ET RDFP1 100W 20 ET RDFP1 100W 30 ET RDFP1 100W 60 ET RDFP1 100W 80 ET RDFP1 100W 100 ET RDFP1 100W 120 ET RDFP1 100W 160 ET RDFP1 100W 200 ET RDFP1 100W 240 Twin Conductor 120/240 VAC 5 W/Ft Ft 1 Inch 25mm XLPE PVC 0 6 Ft (1.8m) Length 18/3 With Plug Voltage Length Ouput Watts Amps Ohms Clips Spacers 120V 20 Ft 5W/Ft 100 0, V 30 Ft 5W/Ft 150 1, V 60 Ft 5W/Ft 300 2, V 80 Ft 5W/Ft 400 3, V 100 Ft 5W/Ft 500 4,2 28, V 120 Ft 5W/Ft V 160 Ft 5W/Ft 800 6, V 200 Ft 5W/Ft ,3 14, V 240 Ft 5W/Ft
14 WA-FSPC FSPC Terminated Heat Cable These heating cables provide pipes, roofs, and gutter systems protection from damage due to freezing, and can be used in residential and commercial applications. The cables automatically adjust heat output according to the ambient temperature conditions. Under cooler conditions the heat output increases, and as the temperature rises the output decreases to save on energy. The cables are available in various pre assembled lengths. Comes in pre cut lengths, seal with cap and plug (120V only) Suitable for plastic or metal gutters and downspouts. suitable for roofs,shingled and metal. will not overheat if overlapped. 240 Volt 120 Volt FSPC Terminated Heat Cable Service Voltage: V V/ V Nominal Cable Width (in/mm) 0.42/10.6 Nominal Cable Thickness (in/mm) 0,23/5.8 Bus Wire Gauge (AWG) Cold Lead Length (in/mm) 16 39/900 Min. Circuit Breaker Size (Amps) 15 Maximum Exposure temperature ( / ) 185/85 Electrical Classification Non Hazardous Chemical Resistance Water And Aqueous Inorganic Chemicals Cable Selection Chart Model 120V/240V Length FSPC1/FSPC2 6 Volt 120/240 Cold Lead Size AWG Power Output on pipe Output on pipe@50 /10 18/18 36 W 30W Output on snow ice@32 / 0 FSPC1/FSPC /240 18/18 72W 60W 120W FSPC1/FSPC /240 18/18 108W 90W 180W FSPC1/FSPC /240 18/18 144W 120W 240W FSPC1/FSPC /240 18/18 225W 187.5W 375W FSPC1/FSPC /240 16/18 300W 250W 500W FSPC1/FSPC /240 16/18 375W 312.5W 625W FSPC1/FSPC /240 16/18 450W 375W 750W FSPC1/FSPC /240 16/18 525W 437.5W 875W FSPC1/FSPC /240 16/16 600W 500W 1000W FSPC1/FSPC /240 14/16 675W 562.5W 1000W FSPC1/FSPC /240 14/16 750W 625W 1250W FSPC1/FSPC /240 14/16 825W 687.5W 1375W FSPC1/FSPC /240 14/16 900W 750W 1500W FSPC W 812.5W 1625W FSPC W 875W 1750W FSPC W 1000W 2000W FSPC W 1125W 2250W FSPC W 1250W 2500W 60W
15 WA-FSPC FSPC - Self Regulating Cable Installation Table 1 Roof Over Hang None 12" 24" 36" 48' A Spacing Factor (ft) B Spacing Factor (in) Shingle Metal Shingle Metal 1,9 2, , ,7 3, ,6 4, ,5 5, FSPC - Self Regulating Cable Installation Choosing the right cable length for pipe tracing Size Type 5 ft 10 ft 15 ft 20 ft 25 ft 30 ft 35 ft 40 ft 45 ft 50 ft 55 ft 60 ft Metal A B C D E E E F F F G G 1/2 Inch 1 Inch 1-1/2 Inch 2 Inch 2-1/2 Inch Plastic A B C E E E E F F F G G Metal A B C D E E E E F F G G Plastic B B C D E E E F F F G G Metal A B C D E E E F F F G G Plastic B C D E E F F G G G H H Metal A B C D E E E F F G G G Plastic B C E F F G G G H H H I Metal A B C E E E E F G G G G Plastic B D E G G G G H I I I J Size Type 65 ft 70 ft 75 ft 80 ft 85 ft 90 ft 95 ft 100 ft 110 ft 120 ft 130 ft 140 ft 150 ft 1/2 Inch 1 Inch 1-1/2 Inch 2 Inch 2-1/2 Inch Metal G G G H H H H H I I J J J Plastic G G G H H H H H I I J J J Metal G G G H H H H H I I J J J Plastic G G H H H H H I I I J J Metal G G G H H H H H I I J J J Plastic H H I I I J J J Metal G G H H H H I I I J J J Plastic I J J Metal G G H H H H I I I J J J Plastic J A B C D E FSPC1 012 FSPC1 018 FSPC1 024 G H I FSPC1 075 FSPC1 100 FSPC1 125 FSPC2 075 FSPC2 100 FSPC2 125 FSPC1 006 F FSPC1 050 FSPC2 050 FSPC1 037 J FSPC1 150 FSPC2 150
16 WA-RDFPIF Ice Free Controller Roof And Gutter Application WA RDFPIF is designed specifically for use with Elec Trace Constant wattage Roof and gutter de icing cable. Designed to sense both temperature and the prensence of run off water, ensuring the heating cable only operates when necessary to prevent ice dams and frozen drains. Both conditions must be met or the system does not run, saving on your energy bill and eliminating waste. Specifically Designed For Elect Trace Cable Sense Both Temperature And Run Off Water Prevent Ice Dams And Frozen Drain Water Resistant Enclosure 120V. Maximum Wattage 1200 W 6 Ft.Cold Lead With Grounded Light Plug Roof And Gutter De-Icing Controller Construction Rated Voltage Max Wattage Application Color Includes Sensor Type Enclosure ABS 120 Volt 1200 Watts Roof/Gutter De Icing Control White Control Unit, Sensor, Shingle Clips Electronic Weather Resistant
17 WA-PSLM-CRT Electric Pipe Heating Cable With Thermostat ET PSLM cable provides freeze protection for pipes in commercial and residential application. Using the latest self regulating technology and a built in thermostat including a pilot indicator showing the presence of power and on/off status, makes these cables both energy efficient and cost effective. These cables are able to adjust their heat output according to the ambient temperature. Electric Pipe Heating Cable With Thermostat Comes in pre cut lengths, with standard 120V/15A cord set. Suitable for use on water filled plastic and metal pipes. Pre Assemble, Ready To Install Cable is built with a tough thermoplastic inner insulation, continuous ground braid and wheather resistant thermoplastic outer Service Voltage 110V 120V Nominal Cable Width (in/mm) Bending Radius (in/mm) / 8 1 / 2.2 Bus Wire (AWG) Cold Lead Length (in/cm) / 61 Min. Circuit Breaker Size (Amps) Maximum Exposure Temperature ( / ) / 40 Electrical Classification Non Hazardous Chemical resistance Water And Aqueous Inorganic Chemicals Thermostat Setting temperature Maximum Switching Current Power Output At 10 /50 On Pipe Cat. Num. ET PSLM CRT1 5 ET PSLM CRT1 10 ET PSLM CRT1 15 ET PSLM CRT1 20 ET PSLM CRT1 35 ET PSLM CRT1 50 ET PSLM CRT1 75 ET PSLM CRT / 38 AC 120V / 12A Voltage Length (ft) Ouput W/ft Output(W) at 10 / Volt Volt Volt Volt Volt Volt Volt Volt
18 WA-SDFP Electric Pipe Heating Cable WA SDFP Pre assemble and ready to install, the cable prevents pipes from freezing, keeping water flowing to 40. Using an energy saving thermostat, ET SDFP cables are suitable for use on water filled plastic and metal pipes. Keeps Water Flowing To 40 Pre Assemble, Ready To Install 2 Ft 18/3 Cold Lead Withgrounded Light Plug With Energy Saving Thermostat Thermostat Located in End Seal Limited Warranty Of 2 Years Electric Pipe Heating Cable Cable Construction: Rated Voltage: Output: Heating Element Size: Bending Radius Conductor Insulation: Outer Insulation: Min. Installation Temp.: Cold Lead: Functions: Supply Voltage: Maximum Switching Current: Setting Temperature: Ambiant Range: Life: Other Twin Conductor 120/240 VAC 7 W/Ft 3 80 Ft 1 Inch 25mm XLPE PVC 10 2 Ft Length 18/3 With Groundeed Light Plug On/Off Control AC 250V Max. AC 120V/12 Amp. AC 240V/10Amp to 105 Standard Use Within 60 Degrees Above The Set Temp. 100,000 Electrical Operations At Rated Load. Cat. Num. Voltage Length Output Total Output Amps Ohms ET SDFP 021W 3 120V 3 7 W 21 0,2 685,7 ET SDFP 042W 6 120V 6 7 W 42 0,4 342,9 ET SDFP 063W 9 120V 9 7 W 63 0,5 228,6 ET SDFP 084W V 12 7 W 84 0,7 171,4 ET SDFP 105W V 15 7 W 105 0,9 137,1 ET SDFP 126W V 18 7 W 126 1,1 114,3 ET SDFP 168W V 24 7 W 168 1,4 85,7 ET SDFP 210W V 30 7 W 210 1,8 68,6 ET SDFP 280W V 40 7 W 280 2,3 51,4 ET SDFP 420W V 60 7 W 420 3,5 34,3 ET SDFP 560W V 80 7 W 560 4,7 25,7
19 WA-5PSL-PW Potable Water Self Regulating Cable NSF/ANSI Standard 61 Potable Water Self Regulating Cable NSF/ANSI Standard 61 WA 5PSL PW is CSA CERTIFIED self regulating parallel heating cable (heating tape) is designed for a variety of potable water applications. It can be used for plastic or metal pipe freeze protection and flow maintenance of pipes, tanks, valves. A UV stabilized thermoplastic elastomer overjacket is provided to cover the braid for wet applications and exposure to the sun. Energy efficient, automatically varies its power output in response to temperature changes. Easy to install, can be cut to any length required on site with no waste. Lower installed cost than steam tracing, less maintenance and downtime. The Fluoropolymer overjacket is NSF/ANSI STANDARD 61 for potable water. Drexma power connection and seal kits will reduce installation time. No overheat or burnout even when overlapped. Maximum length vs circuit breaker size Min. Temperature 10 (50 ) 0 (32 ) CB size 120 Volt 240 Volt Amps Ft M Ft M Cable Construction , , , , , , , , , , , , , ,4 Technical Data , ,6 Service voltage , ,1 Max. maintain , ,9 temperature Power Output Curves Max. intermitent temperature Min. installation temperature Protective braid resistance Bus wire gauge V, V +65 (149 ) +85 (185 ) 40 ( 40 ) <18.2Ω/km 16AWG Pipe Temperature
20 WA-PSLM-8MM 8 mm PSLM Self Regulating Cable WA PSLM cables are ideal for freeze protection & process temperature maintenance on pipe, tanks and valves for residential and commercial applications. These cables use the latest self regulating technology adjusting heat output according to the ambient temperature, making them energy efficient and cost effective. Cable can be cut to desired length and overlapped without risk of overheating. Suitable for metal or plastic surfaces. Lower installation and maintenance cost than steam tracing. Tinned copper braid provides additional protection to the cable core. Flame retardant thermoplastic outer jacket option, protects against certain chemical solution,abrasion and impact damage. 8 mm PSLM Self Regulating Cable Product Number PSL M C For Example: 5PSL M2 CR Jacket Chemical Resistance Nominal Thickness (mm) Nominal Width (mm) Minimum Bending Radius (mm) Weight (kg/100m) Electrical Classification Service Voltage Max. Maintain or Continous Exposure Temperature (power on) Max. Intermitent Exposure Temperature 100 Hours (power on) Minimum Installation Temperature Protective Braid resistance Bus Wire Gauge Outer Jacket R=Thermoplastic Thinned Copper Braid Supply Voltage 1= V / 2= V Type Of Heating Cable Output Power Per Ft At 10 3=3W/ft; 5=5W/ft; 8=8W/ft. PSL M C N/A Moisture 4,1 6, V/ V PSL M CR Thermoplastic Aqueous Inorganic Solutions 5,7 8,3 34 7,5 Non Hazardous V/ V 65 (149 ) 85 (185 ) 40 ( 40 ) <18.2 Ω/km 20 AWG
21 WA-PSLM-8MM PowerOutput Curves At 120V/240V Installed On Insulated Metal Pipes Power output Rating 8 mm PSLM Self Regulating Cable Pipe Temperature Cable Lenght Per Breaker size Start up 120V 240V Temperature 10A 15A 20A 10A 15A 20A 3PSL M PSL M PSL M
22 WA-HTLe-CR-11MM 11 mm HTLe-CR Self Regulating Cable WA HTLe CR cables are ideal for freeze protection & process temperature maintenance on pipe, tanks and valves for residential and commercial applications. These cables use the latest self regulating technology adjusting heat output according to the ambient temperature, making them energy efficient and cost effective. 11 mm HTLe-CR Self Regulating Cable Cable can be cut to desired length and overlapped without risk of overheating. Suitable for metal or plastic surfaces. Lower installation and maintenance cost than steam tracing. Tinned copper braid provides additional protection to the cable core. Flame retardant thermoplastic outer jacket option, protects against certain chemical solution,abrasion and impact damage. Product Number HTLe C For Example: 3HTLe 2 CR Jacket Chemical Resistance Nominal Thickness (mm) Nominal Width (mm) Minimum Bending Radius (mm) Weight (kg/100m) Electrical Classification Service Voltage Max. Maintain or Continous Exposure Temperature (power on) Max. Intermitent Exposure Temperature 100 Hours (power on) Minimum Installation Temperature Protective Braid resistance Bus Wire Gauge Outer Jacket R=Thermoplastic Thinned Copper Braid Supply Voltage 1= V / 2= V Type Of Heating Cable Output Power Per Ft At 10 3=3W/ft; 5=5W/ft; 8=8W/ft; 10=10W/ft. HTLe C N/A Moisture 4,4 9,3 26 9,7 HTLe CR Thermoplastic Aqueous Inorganic Solutions 6 10, Non Hazardous V/ V 65 (149 ) 85 (185 ) 40 ( 40 ) <18.2 Ω/km 16 AWG
23 WA-HTLe-CR-11MM 11 mm HTLe-CR Self Regulating Cable Power output Rating 10 HTLe 8HTLe 5 HTLe 3 HTLe 11 mm HTLe-CR Self Regulating Cable Pipe Temperature Start up 120V 240V Temperature 10A 15A 20A 30A 10A 15A 20A 30A 3 HTLe HTLe HTLe C HTLe HTLe HTLe
24 WA-PSL-13MM 13 mm Self Regulating Cable WA PSL cables are ideal for freeze protection & process temperature maintenance on pipe, tanks and valves for residential and commercial applications. These cables use the latest self regulating technology adjusting heat output according to the ambient temperature, making them energy efficient and cost effective. Cable can be cut to desired length and overlapped without risk of overheating. Suitable for metal or plastic surfaces. Lower installation and maintenance cost than steam tracing. Tinned copper braid provides additional protection to the cable core. Flame retardant thermoplastic outer jacket option, protects against certain chemical solution,abrasion and impact damage. Product Number 13 mm Self Regulating Cable PSL C For Example: 3PSL2 CR Jacket Chemical Resistance Nominal Thickness (mm) Nominal Width (mm) Minimum Bending Radius (mm) Weight (kg/100m) Electrical Classification Service Voltage Max. Maintain or Continous Exposure Temperature (power on) Max. Intermitent Exposure Temperature 100 Hours (power on) Minimum Installation Temperature Protective Braid resistance Bus Wire Gauge Outer Jacket R=Thermoplastic Thinned Copper Braid Supply Voltage 1= V / 2= V Type Of Heating Cable Output Power Per Ft At 10 3=3W/ft; 5=5W/ft; 8=8W/ft; 10=10W/ft; 12=12W/ft. PSL C N/A Moisture 4, , V/ V PSL CR Thermoplastic Aqueous Inorganic Solutions 6 12, ,8 Non Hazardous V/ V 65 (149 ) 85 (185 ) 40 ( 40 ) <18.2 Ω/km 16 AWG
25 WA-PSL-13MM PowerOutput Curves At 120V/ V Installed On Insulated Matel Pipes And Power Ajustment Factors Ajustment factors Power output Rating 208V Power Output Circuit Length 3PSL 0,82 0,96 5PSL 0,85 0,94 0,89 0,92 0,89 0,92 0,89 0,92 Pipe Temperature 8PSL 10PSL 12PSL 277V 3PSL 5PSL 8PSL 10PSL 12PSL 1,13 1,12 1,08 1,08 1,08 1,08 1,09 1,11 1,11 1,11 13 mm Self Regulating Cable Cable Lenght Per Breaker Size Start up Temperature 10A 15A 120V 20A 30A 40A 10A 15A 240V 20A 30A 40A 3 PSL PSL PSL PSL V/ V/ PSL
26
Heating Cables. For Industry Tracing
Heating Cables For Industry Tracing FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length
More informationHeating Cable. Cut to Length in Field. Description
Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection
More informationNAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION
Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet
More informationPower Connection Kit installation instructions
Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
More informationType LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations
A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the
More informationType LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations
F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive
More informationType HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations
E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,
More informationNAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930
PRODUCT CODES NAMSR-Wattage-Voltage-Length // eg: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly
More informationSelf-Regulating Freeze Protection Heating Cable
D PDS SRF Self-Regulating Freeze Protection Heating Cable E C B A Output Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Freeze Protection of
More informationNAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930
PRODUCT CODES NAMSR-Wattage-Voltage-Length. Ex: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly
More informationElectric Heating Product Catalog
Version #: VKAPA922 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage COMFORT and safety solutions for
More informationModified polyolefin (-CR) or fluoropolymer (-CT) outer jacket
SELF-REGULATING HEATING CABLE For pipe freeze protection and flow maintenance Heating cable construction Tinned-copper braid Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket Modified polyolefin
More informationSelection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &
More informationDanfoss Electric Heating Products 2012 CATALOG BRINGING WARMTH TO LIFE. Electric Floor Heating
BRINGING WARMTH TO LIFE Electric Floor Heating Electric Snow Melting Roof & Gutter De-Icing Pipe Freeze Protection Thermal Storage PG. 1 PG. 9 PG. 21 PG. 25 PG. 31 Danfoss Electric Heating Products 2012
More informationWarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing
WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife
More informationSelf-Regulating Cables
Self-Regulating 1. Self- Regulating 2. Power- Limiting This step-by-step design guide provides the tools necessary to design a self-regulating heat-tracing system for insulated pipes and tubing. For other
More informationSELF-REGULATING CABLES
Self-Regulating SELF-REGULATING CABLES This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications
More informationElectric Heating Product Catalog
Version #: VKAPA522 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage www.heating.danfoss.us Danfoss
More informationSelf-regulating cables
Self-Regulating Self-regulating cables This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications
More informationIntroduction to Heat Trace Cable Systems
Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).
More informationProduct Overview. Application
Self-Regulating SC, SC/H Series-resistance heating cables for longline systems Electrical freeze protection for long pipelines in both nonhazardous and hazardous locations Power-Limiting Mineral Insulated
More informationDOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug
DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant
More informationNuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket
Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner
More informationPower-Limiting Cables
Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your
More information3M Self Regulating Heating Cables
2 Construction & Function 3M Self Regulating Heating Cables Introduction: 3M Canada and Thermon Manufacturing Company have entered into a strategic alliance to market the commercial line of heat tracing
More informationIndustrial, Heavy Insulated Mono-Tape. and Duo-Tape
Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating
More informationPIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM
PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace pipe freeze protection or flow maintenance system. For
More informationPictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...
Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss
More informationfrost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers
frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Heating systems protect pipes, valves, actuators and other elements vulnerable to harmful influence
More informationFREEZSTOP MICRO SYSTEM
FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 25mm diameter water pipe at +5
More informationINDUSTRIAL HEAT TRACE
INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE www.valin.com 800-774-5630 www.valin.com HTS-6 SERIES The HTS-6 commercial grade heater cable is designed for use in both indoor and outdoor locations as well
More informationMI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction
MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE For commercial and industrial applications Heating cable construction Insulation (magnesium oxide) Heating conductor Copper sheath HDPE
More informationV (For 120, 208, 277, 600 V, please call.) Output: 37 W/ft 2 and 50W/ft 2 Cold lead:
Snow Melting Mats Data Sheet GENERAL PRODUCT INFORMATION ProLine snow melting mats feature pre-spaced heat cable (3 and 4-inch spacing) in mats that can be rolled out for quick, easy installation. To make
More informationEcoflex potable PEX plus pre-insulated pipe system Installation guide
Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system installation guide l 1 Uponor Ecoflex potable PEX plus pre-insulated pipe system
More informationHEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath
Introduction to Heat Trace Cable Systems...6-2 Mineral Insulated Heat Trace Cable...6-2 Non-Metallic Sheath Heat Trace Cable...6-2 Installation Details...6-4 Engineering Guide for Mineral Insulated Cable...6-5
More informationElectric Heating Product Catalog
Version #: VKAPA422 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage www.lx.danfoss.com Danfoss offers
More informationC A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS
C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a
More informationProduct Catalogue. Worldwide Specialists in Electric Heat Tracing. HTS THERMTRACE HTS THERMTRACE HTS T
Product Catalogue HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE www.hts-global.com is an international operating manufacturer of electric heating
More informationPre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL
Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A
More informationHOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines
HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines PVC jacket - Deg C (optionally PUR material) Glass fibre thermal insulation Process tube(s) Heat reflective tape Electrical heating
More informationPRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)
PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire
More informationDanfoss LX Electric Floor Heating
Danfoss LX Electric Floor Heating Electric Floor Heating Thermostats The Danfoss LX Thermostat raises the bar for aesthetic appeal while offering industry-leading functionality. The LX electronic thermostat
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More informationINSTALLATION GUIDELINES. Design system and make a layout. For guidance, see attached layout and wiring diagram.
INSTALLATION GUIDELINES 1. Plan Design system and make a layout. For guidance, see attached layout and wiring diagram. Heating elements should be placed on top of the ice and water shield. Between the
More informationSelf-Regulating Parallel Heating Cables. innovations in heat tracing
Self-Regulating Parallel Heating Cables innovations in heat tracing ELSR Application Options The application options for the ELSR heating cables range from freeze protection to maintenance of pipes and
More informationC A Heating Cable Gland Kit Installation Instructions
C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a
More informationFREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework
FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation
More informationPre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL
Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A
More informationSEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399
DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is
More informationFrost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor
Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient
More informationHeat Tracing Products
Applications Electric Industrial Process Maintenance Applications Commercial Applications Chromalox heating cable line includes cables suitable for most process maintenance, pipe and vessel freeze protection
More informationÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.
Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with
More informationSnow Melting Mats Price Sheet
Snow Melting Mats Price Sheet EFFECTIVE : 201 WarmlyYours Snow Melting Mats are available in a variety of sizes and voltages to meet your requirements. The following pricing guide has been designed to
More informationH900 WinterGard Power Connection Kit with End Seal Installation Instructions
H900 WinterGard Power Connection Kit with End Seal Installation Instructions Power connection for H311, H611, and H621 Power connection for H612 and H622 Description The WinterGard power connection kit
More information37T Series Moisture Resistant Temperature Controls
37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a
More informationMI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration
MI Heating Cable HDPE jacketed, copper sheathed MI cable For surface snow melting in concrete, asphalt, and pavers Pipe Freeze Protection and Flow Maintenance Fire Sprinkler System Freeze Protection MI
More informationSelf-regulating heating cables with a non-heating service cable
N144/R02(22.08.18) Self-regulating heating cables with a non-heating service cable ELSR-M-15-2-BO ELSR-N--2-AO ELSR-N-30-2-AO GENERAL CONDITIONS The connector which connects the cold end and the heating
More informationFrost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor
Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient
More informationSpecification for Heated Instrument Tubing in Process Applications* (March 29, 2007)
Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) 1.0 SCOPE This specification outlines the minimum requirements for electrically traced or steam/fluid traced instrument
More informationPipe Freeze Protection Design/Install Guide
Pipe Freeze Protection Design/Install Guide Page 1 of 16 Pipe Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 STEP 1 Information Required Page 4 STEP 2 Design Considerations Page
More informationELSR Electric Self-Regulating Parallel Heating Cables
ELSR Electric Self-Regulating Parallel Heating Cables www.hazlocheaters.com www.eltherm.ca 1 Eltherm, a German manufacturer, and Hazloc Heaters (part of The Ouellet Canada Group) have formed a strategic
More informationCAPABILITIES EXPERT TECHNICAL SUPPORT
Heat Trace Systems CAPABILITIES HEAT TRACE SOLUTIONS Cables Controllers Sensors Accessories EXPERT TECHNICAL SUPPORT Chromalox heat trace products and services save you time, reduce the cost of ownership,
More informationCorflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3
Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation
More informationHeating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
More informationManufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation
More information0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR
TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE
More informationHeating Cable. Description
203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal
More informationCABLED TWISTED PAIRS CONDUCTORS
CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete
More informationXL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance
XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal building solutions WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK
More informationCABLED SINGLE CONDUCTORS
CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of
More informationSRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions
SRK02 Hard Wire Power Connection Kit Installation, Operation and Maintenance Instructions IMPORTANT: Save These Instructions! Item Qty Description A 1 Black heat shrink tube (1/2 dia. x 1 length) B 2 Black
More informationC Power Connection Kit
1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is
More informationAutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).
R AMG-BC-III AutoMatrix Power Connection Kit Description The AMG-BC-III is a copper free aluminum (maximum 4/10 of 1% copper) NEMA 4X (1) rated power connection kit for single or dual heating cable entry.
More informationÖLFLEX CLASSIC 115 CY
Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationHeating Cable. Construction
MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)
More informationHEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS CLOSED- AND OPEN-LOOP CONTROL SYSTEMS HEATERS WATER LEAKAGE DETECTION SYSTEMS
HEATING TECHNOLOGY HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS 1 CLOSED- AND OPEN-LOOP CONTROL SYSTEMS 2 HEATERS 3 WATER LEAKAGE DETECTION SYSTEMS 4 PROJECT PLANNING INFORMATION 5 CONTENT
More informationHeating Cables Heating Tapes. innovations in heat tracing
Heating Cables Heating Tapes innovations in heat tracing Table of Contents Introduction 3 Type ELP/SI Constant Wattage Heating Cable up to 200 C 4-5 Type ELP/SI-F Constant Wattage Heating Cable up to 200
More information600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)
600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power
More informationCAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems
Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022
More informationA/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)
A/C Disconnects 60 amps Non-fused. 240v A.C. Single Phase. UL Listed Three piece construction that opens up mounting and wiring areas, reduces installation time. Terminals approved for 60*C and 75*C wire.
More informationFLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES
FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.
More informationSolutions in Rail Heating Systems. Rail Heating Proposal. Innovations in heat tracing
Solutions in Rail Heating Systems Rail Heating Proposal Innovations in heat tracing Innovations in heat tracing eltherm our company How can we protect antennas from ice in frosty weather? How can we transport
More informationJBM-100-STB NEMA 4X-rated connection kit Installation Instructions
JBM-100-STB NEMA 4X-rated connection kit Installation Instructions Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box Approvals Hazardous Locations CLI,
More informationTC-THHN/THWN-2 Copper, PVC/Nylon Insulated
TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets
More informationRevision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide
Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationPRODUCT NAME ORDER # PAGE # ANTENNAS
PRODUCT NAME ORDER # PAGE # ANTENNAS 890-960 Yagi Antenna UBR-Y9000 w/ lead 0580 450 Mhz Yagi Antenna UBR-Y4000 w/ lead 05803 806-960 & 70-990 MHz Dual Band Omni Antenna 09835 3 806-960 & 70-500 Yagi Multiband
More information0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.
TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING
More informationCABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue
CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main
More informationgrounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2
grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationCORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...
w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC
More informationDRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.
DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,
More informationÖLFLEX CLASSIC 110 CY
Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationTHERMOCOUPLE CABLES THERMOELECTRICITY
THERMOCOUPLE CABLES THERMOELECTRICITY When a metallic conductor is exposed to a difference of temperature between the two extremities, an electromotive force (emf) is generated by the temperature gradient,
More informationEMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions
EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating
More informationRMP SERIES INFORMATION GUIDE
RMP SERIES INFORMATION GUIDE DESCRIPTION & DESIGN FEATURES Applications RMP series connectors can be used wherever high amperage connection of AC or DC power is required. Typical applications are the connection
More informationEngineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)
4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices
More informationCoupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut
Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68
More information