120/240 Volts 3 Watt Floor Heating Cable System

Size: px
Start display at page:

Download "120/240 Volts 3 Watt Floor Heating Cable System"

Transcription

1

2 WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable and energy efficient. 120/240 Volts 3 Watt Floor Heating Cable System Easy Installation Emits Zero EMF 25 Year Limited warranty Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Ambient Temp. Min. Installation Temp. Cold Lead Length Model 3CWC 120V 10 3CWC 120V 15 3CWC 120V 20 3CWC 120V 25 3CWC 120V 30 3CWC 120V 35 3CWC 120V 40 3CWC 120V 45 3CWC 120V 50 3CWC 120V 60 3CWC 120V 70 3CWC 120V 80 3CWC 120V 90 3CWC 120V 100 3CWC 120V 110 3CWC 120V 120 3CWC 120V 130 3CWC 120V 140 ohms 3CWC 120V 150 watt amp 120 Volts Length Twin Conductor 120V / 240V 3W/ft (9.84W/m) 40' (12.2m) to 1200' (365.8m) 1" (25.4mm) 1/8" 1/5" (3.3mm 5.0mm) Fluoropolymer Fluoropolymer,TPE or Nylon 85 (30 ) 40 (5 ) 2 Wire 16 AWG Plus Ground Braid 10 ft. (3m) Thickness Covers / SqFt Spacing Ft (mm) 2" 3" 4" , ,5 60 3, , , , , , , , , , , , , , , , , , , , ,

3 WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient. 120/240 Volts 3 Watt Floor Heating Cable System Approved For Showers Durable Construction Single Point Connection 25 Year Limited warranty 240 Volts Covers / SqFt Length Thickness Model ohms watt amp Spacing Ft (mm) 2" 3" 4" 3CWC 240V ,5 40 3, CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , , CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , , CWC 240V , , CWC 240V 70 68, , CWC 240V , , CWC 240V 90 53, , , CWC 240V , CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , CWC 240V , , CWC 240V , CWC 240V , CWC 240V , CWC 240V , , CWC 240V , CWC 240V

4 WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable Structure Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient. 120/240 Volts 3 Watt Floor Heating Cable Structure Approved For Showers Durable Construction Single Point Connection 25 Year Limited warranty Cable diameter mm 120 Volts from 10 Sq.Ft. to 80 Sq.Ft. 240 Volts from 10 Sq.Ft. to 160 Sq.Ft. Cable diameter mm 120 Volts from 90 Sq.Ft. to 150 Sq.Ft. 240 Volts from 180 Sq.Ft. to 300 Sq.Ft.

5 WA-3.7CWC 3.7 Watt Floor Heating Cable System For Uncoupling Membrane 3.7 Watt Floor Heating Cable System For Uncoupling Membrane Warm Cable floor heating system for uncoupling membrane combines the highest comfort levels with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient. Easy Installation Emits Zero EMF 25 Year Limited warranty Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Ambient Temp. Min. Installation Temp. Cold Lead Length Model ohms watt amp 120 Volts Length Twin Conductor 120V / 240V 3.7W/ft (12.14W/m) 16.5' (5m) to 990' (301.75m) 1" (25.4mm) 1/5" (4.9mm) Fluoropolymer PVC 85 (30 ) 40 (5 ) 2 Wire 16 AWG Plus Ground Braid 10 ft (3m) Length Covers SqFt Spacing Ft M 3,5" 3,75" 3,7CWC 120V ,5 16,5 5,05 4,8 5,2 3,7CWC 120V ,1 9,6 10,3 3,7CWC 120V ,5 49,5 15,1 14,4 15,5 3,7CWC 120V ,1 19,3 20,6 3,7CWC 120V ,5 82,5 25,1 24,1 25,8 3,7CWC 120V ,2 28,9 30,9 3,7CWC 120V 34 32, ,5 115,5 35,2 33,7 36,1 3,7CWC 120V ,2 38,5 41,3 3,7CWC 120V 43 26, ,5 148,5 45,3 43,3 46,4 3,7CWC 120V ,3 48,1 51,6 3,7CWC 120V ,4 57,8 61,9 3,7CWC 120V 67 17, ,4 67,4 72,2 3,7CWC 120V , ,5 3,7CWC 120V 87 13, ,5 86,6 92,8 3,7CWC 120V ,6 96,3 103,1 3,7CWC 120V , ,6 105,9 113,4 3,7CWC 120V ,7 115,5 123,8 3,7CWC 120V 125 9, ,8 125,1 134,1 3,7CWC 120V 135 8, ,8 134,8 144,4 3,7CWC 120V ,9 144,4 154,7 Saint Basile Le Grand, Quebec,J3N 1A1

6 WA-3.7CWC Floor Heating Cable System For Uncoupling Membrane Floor Heating Cable System For Uncoupling Membrane Easy Installation Emits Zero EMF 25 Year Limited warranty 240 Volts Model ohms watt amp Length Length Covers SqFt Spacing Ft M 3,5" 3,75" 3,7CWC 240V , ,1 9,6 10,3 3,7CWC 240V ,8 49,5 15,1 14,4 15,5 3,7CWC 240V ,1 19,3 20,6 3,7CWC 240V ,3 82,5 25,1 24,1 25,8 3,7CWC 240V , ,2 28,9 30,9 3,7CWC 240V , ,8 115,5 35,2 33,7 36,1 3,7CWC 240V ,2 38,5 41,3 3,7CWC 240V , ,3 148,5 45,3 43,3 46,4 3,7CWC 240V , ,2 48,1 51,6 3,7CWC 240V ,4 57,8 61,9 3,7CWC 240V 67 68, , ,4 67,4 72,2 3,7CWC 240V , ,5 3,7CWC 240V 87 53, , ,6 86,6 92,8 3,7CWC 240V ,6 96,3 103,1 3,7CWC 240V ,8 115,5 123,8 3,7CWC 240V , ,8 134,8 144,4 3,7CWC 240V ,7CWC 240V , ,3 185,6 3,7CWC 240V ,2 192,5 206,3 3,7CWC 240V , ,2 211,8 226,9 3,7CWC 240V , ,5 3,7CWC 240V , ,6 250,3 268,1 3,7CWC 240V , ,6 269,5 288,8 3,7CWC 240V ,8 288,8 309,4 Saint Basile Le Grand, Quebec,J3N 1A1

7 WA-3.7CWC Floor Heating Cable System For Uncoupling Membrane Floor Heating Cable System For Uncoupling Membrane Easy Installation Emits Zero EMF 25 Year Limited warranty Cable diameter 4.9 mm 120 Volts from 05 Sq.Ft. to 106 Sq.Ft. 240 Volts 10 Sq.Ft. to 212 Sq.Ft. Cable diameter 4.9 mm 120 Volts from 115 Sq.Ft. to 144 Sq.Ft. 240 Volts 231 Sq.Ft. to 289 Sq.Ft. Saint Basile Le Grand, Quebec,J3N 1A1

8 WA-6CTS Thermal Storage Cable 6W Thermal Storage Cable 6W is the ideal solution for interior imbeded concrete slab. Single Point Connection Twin Conductor Cable Silent, Efficient And Safe Emits Zero EMF Easy And Flexible Installation Durable Construction Limited Warranty Thermal Storage Cable 6W Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Rated Temperature Min. Installation Temperature Cold Lead Length Cable Sizes Cat. Num. 6CTS 240V 0240W 6CTS 240V 0344W 6CTS 240V 0515W 6CTS 240V 0683W 6CTS 240V 0852W 6CTS 240V 1026W 6CTS 240V 1226W 6CTS 240V 1395W 6CTS 240V 1735W 6CTS 240V 2072W 6CTS 240V 2410W 6CTS 240V 2756W 6CTS 240V 3097W 6CTS 240V 3470W Twin Conductor 120V / 240V 6W/ft (20W/m) 55' (16.8m) to 680' (207.3m) 1.5" (38mm) 1/4 (6.5mm) Fluoropolymer And XLPE PVC 220 (105 ) 40 (5 ) 10 ft (6m) Length Cable Covers /per/sq.ft. Output Ft M 18W 4" 15W 5" 12W 6" Watts Amps Ohms 40 12,2 13,3 16,7 20, ,0 240, ,3 20,0 25,0 30, ,4 167, ,4 30,0 37,5 45, ,1 111, ,1 38,3 47,9 57, ,8 84, ,2 48,3 60,4 72, ,6 67, ,3 58,3 72,9 87, ,3 56, ,0 70,0 87,5 105, ,1 47, ,2 80,0 100,0 120, ,8 41, ,4 100,0 125,0 150, ,2 33, ,2 118,3 147,9 177, ,6 27, ,5 138,3 172,9 207, ,0 23, ,3 156,7 195,8 235, ,5 20, ,5 176,7 220,8 265, ,9 18, ,4 198,3 247,9 297, ,5 16,6 Saint Basile Le Grand, Quebec,J3N 1A1

9 WA-9CTS Thermal Storage Cable 9W Thermal Storage Cable 9 Watt is the ideal solution for interior imbeded concrete slab. Single Point Connection Twin Conductor Cable Silent, Efficient And Safe Emits Zero EMF Flexible Cable Durable Construction 2 Year Limited Warranty Thermal Storage Cable 9W Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Rated Temperature Min. Installation Temperature Cold Lead Length Cable Sizes Cat. Num. 9CTS 240V 0420W 9CTS 240V 0625W 9CTS 240V 0840W 9CTS 240V 1083W 9CTS 240V 1260W 9CTS 240V 1762W 9CTS 240V 2150W 9CTS 240V 2595W 9CTS 240V 3130W 9CTS 240V 3469W Twin Conductor 120V / 240V 9W/ft (30W/m) 57' (17.4m) to 610' (185.9m) 1.5" (38mm) 1/4 (6.5mm) Fluoropolymer And XLPE PVC 220 (105 ) 40 (5 ) 20 ft (6m) Length Cable Covers /Per/Sq.Ft. Output Ft M 28W 4" 22W 5" 18W 6" Watts Amps Ohms 46 14,0 15,3 19,2 23, ,8 137, ,3 23,3 29,2 35, ,6 92, ,0 30,7 38,3 46, ,5 68, ,1 38,3 47,9 57, ,5 53, ,7 46,7 58,3 70, ,3 45, ,9 63,3 79,2 95, ,3 32, ,2 80,0 100,0 120, ,0 26, ,9 95,0 118,8 142, ,8 22, ,6 110,0 137,5 165, ,6 19, ,3 125,0 156,3 187, ,5 16,6

10 WA-12CSW Safe Walk Cable 12W Safe Walk Cable 12 Watt is the ideal solution for exterior imbeded concrete slab, pavers and asphalt. Single Point Connection Twin Multi Braided Conductor Silent, Efficient And Safe Emits Zero EMF Easy And Flexible Installation Durable Construction 20 Year Limited Warranty Cable Construction Rated Voltage Output Heating Element Size Bending Radius Cable Diameter Conductor Insulation Outer Insulation Max. Rated Temperature Min. Installation Temperature Cold Lead Length Twin Conductor 240V / 208V / 600V 12W/ft (40W/m) 35' (10.7m) to 940' (286.5m) 1.5" (38mm) 1/4 (6.5mm) Fluoropolymer And XLPE PVC 220 (105 ) 40 (5 ) 20 ft (6m) Safe Walk Cable 12W Cable Sizes 208 Volt Cat. Num. 12CSW 208V 0420W 12CSW 208V 0600W 12CSW 208V 0840W 12CSW 208V 1020W 12CSW 208V 1260W 12CSW 208V 1500W 12CSW 208V 1740W 12CSW 208V 1920W 12CSW 208V 2160W 12CSW 208V 2520W 12CSW 208V 2940W 12CSW 208V 3360W 12CSW 208V 3810W 12CSW 208V 4260W 12CSW 208V 4920W 12CSW 208V 5520W Length Cable Covers Per Sq.Ft. Output Ft M 48W 4" 36W 5" 29W 6" Watts Amps Ohms 35 10,7 8,8 11,7 14, ,0 103, ,2 12,5 16,7 20, ,9 72, ,3 17,5 23,3 29, ,0 51, ,9 21,3 28,3 35, ,9 42, ,0 26,3 35,0 43, ,1 34, ,1 31,3 41,7 52, ,2 28, ,2 36,3 48,3 60, ,4 24, ,8 40,0 53,3 66, ,2 22, ,9 45,0 60,0 75, ,4 20, ,0 52,5 70,0 87, ,1 17, ,7 61,3 81,7 102, ,1 14, ,3 70,0 93,3 116, ,2 12, ,5 80,0 106,7 133, ,5 11, ,2 88,8 118,3 147, ,5 10, ,0 102,5 136,7 170, ,7 8, ,2 115,0 153,3 191, ,5 7,8

11 WA-12CSW Safe Walk Cable 12W Safe Walk Cable 12 Watt is the ideal solution for exterior imbeded concrete slab. Watt output of the 240V cable is reduced by 25% when operated at 208V Watt output of the 600V cable is reduced by 35% when operated at 480V Single Point Connection Twin Conductor Cable Silent, Efficient And Safe Emits Zero EMF Easy And Flexible Installation Durable Construction 20 Year Limited Warranty Cable Sizes Safe Walk Cable 12W 240 Volt Cat. Num. 12CSW 240V 0480W 12CSW 240V 0720W 12CSW 240V 0960W 12CSW 240V 1200W 12CSW 240V 1440W 12CSW 240V 1740W 12CSW 240V 1980W 12CSW 240V 2220W 12CSW 240V 2460W 12CSW 240V 2940W 12CSW 240V 3420W 12CSW 240V 3900W 12CSW 240V 4440W 12CSW 240V 4920W 12CSW 240V 5700W 12CSW 240V 6420W 600 Volt Cat. Num. 12CSW 600V 1240W 12CSW 600V 1855W 12CSW 600V 3080W 12CSW 600V 3690W 12CSW 600V 4425W 12CSW 600V 5040W 12CSW 600V 5650W 12CSW 600V 6265W 12CSW 600V 7485W 12CSW 600V 8705W Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 40 12,2 10,0 13,3 16, ,0 120, ,3 15,0 20,0 25, ,0 80, ,4 20,0 26,7 33, ,0 60, ,5 25,0 33,3 41, ,0 48, ,6 30,0 40,0 50, ,0 40, ,2 36,3 48,3 60, ,3 33, ,3 41,3 55,0 68, ,3 29, ,4 46,3 61,7 77, ,3 25, ,5 51,3 68,3 85, ,3 23, ,7 61,3 81,7 102, ,3 19, ,9 71,3 95,0 118, ,3 16, ,1 81,3 108,3 135, ,3 14, ,8 92,5 123,3 154, ,5 13, ,0 102,5 136,7 170, ,5 11, ,8 118,8 158,3 197, ,8 10, ,1 133,8 178,3 222, ,8 9,0 Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watt Amps Ohms ,5 25,0 33,3 41, ,1 290, ,7 37,5 50,0 62, ,1 194, ,2 62,5 83,3 104, ,1 116, ,4 75,0 100,0 125, ,2 97, ,7 90,0 120,0 150, ,4 81, ,5 103,8 138,3 172, ,4 71, ,7 116,3 155,0 193, ,4 63, ,0 128,8 171,7 214, ,4 57, ,5 153,8 205,0 256, ,5 48, ,6 178,5 238,0 297, ,5 41,4

12 WA-12CSW Safe Walk Cable 12W Cable Sizes 277 Volt Cat. Num. 12CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V CSW 277V Volt Cat. Num. 12CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V CSW 347V Volt Cat. Num. 12CSW 480V CSW 480V CSW 480V CSW 480V CSW 480V CSW 480V CSW 480V Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 50,0 15,2 12,5 16,7 20, ,9 145,8 70,0 21,3 17,5 23,3 29, ,1 89,4 95,0 29,0 23,8 31,7 39, ,0 69,3 115,0 35,1 28,8 38,3 47, ,2 53,3 140,0 42,7 35,0 46,7 58, ,1 45,4 170,0 51,8 42,5 56,7 70, ,3 38,5 190,0 57,9 47,5 63,3 79, ,4 33,0 215,0 65,5 53,8 71,7 89, ,4 29,5 240,0 73,2 60,0 80,0 100, ,3 26,9 285,0 86,9 71,3 95,0 118, ,5 22,3 330,0 100,6 82,5 110,0 137, ,5 19,1 375,0 114,3 93,8 125,0 156, ,6 16,7 425,0 129,5 106,3 141,7 177, ,6 14,9 475,0 144,8 118,8 158,3 197, ,8 13,3 545,0 166,1 136,3 181,7 227, ,9 11,7 Length Cable Covers Per Sq.Ft. Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 60,0 18,3 4,6 6,1 7, ,1 167,2 90,0 27,4 6,9 9,1 11, ,1 112,5 115,0 35,1 8,8 11,7 14, ,1 84,5 145,0 44,2 11,0 14,7 18, ,1 67,7 175,0 53,3 13,3 17,8 22, ,2 56,4 210,0 64,0 16,0 21,3 26, ,4 47,0 240,0 73,2 18,3 24,4 30, ,4 41,3 300,0 91,4 22,9 30,5 38, ,4 33,2 355,0 108,2 27,1 36,1 45, ,5 27,8 415,0 126,5 31,6 42,2 52, ,5 23,9 470,0 143,3 35,8 47,8 59, ,6 20,9 530,0 161,5 40,4 53,8 67, ,6 18,6 595,0 181,4 45,3 60,5 75, ,9 16,6 680,0 207,3 51,8 69,1 86, ,9 14,5 Length Cable Covers SqFt Output Ft M 50W 3" 35W 4" 18W 5" Watts Amps Ohms 80,0 24,4 20,0 26,7 33, ,1 232,0 200,0 61,0 50,0 66,7 83, ,1 93,5 330,0 100,6 82,5 110,0 137, ,4 57,1 490,0 149,4 122,5 163,3 204, ,5 38,5 735,0 224,0 183,8 245,0 306, ,6 25,7 820,0 249,9 205,0 273,3 341, ,9 23,0 940,0 286,5 235,0 313,3 391, ,9 20,1

13 WA-RDFP Electric Roof De-Icing Cable WA RDFP roof and gutter de icing help and prevents costly ice damage by preventing ice dam formation and promoting the free flow of water through gutters and downspouts to groung level. Available From 20 to 240 Feet Prevents roof and damage and leaking Keeps Gutter And Downspout Flowing Pre Assemble, Ready To Install 6 Ft 18/3 Cold Lead With Plug Limited Warranty Of 2 Years Electric Roof De-Icing Cable Cable Construction: Rayed Voltage: Output: Heating Element Size: Bending Radius Conductor Insulation: Outer Insulation: Min. Installation Temp.: Cold Lead: Other Cat. Num. ET RDFP1 100W 20 ET RDFP1 100W 30 ET RDFP1 100W 60 ET RDFP1 100W 80 ET RDFP1 100W 100 ET RDFP1 100W 120 ET RDFP1 100W 160 ET RDFP1 100W 200 ET RDFP1 100W 240 Twin Conductor 120/240 VAC 5 W/Ft Ft 1 Inch 25mm XLPE PVC 0 6 Ft (1.8m) Length 18/3 With Plug Voltage Length Ouput Watts Amps Ohms Clips Spacers 120V 20 Ft 5W/Ft 100 0, V 30 Ft 5W/Ft 150 1, V 60 Ft 5W/Ft 300 2, V 80 Ft 5W/Ft 400 3, V 100 Ft 5W/Ft 500 4,2 28, V 120 Ft 5W/Ft V 160 Ft 5W/Ft 800 6, V 200 Ft 5W/Ft ,3 14, V 240 Ft 5W/Ft

14 WA-FSPC FSPC Terminated Heat Cable These heating cables provide pipes, roofs, and gutter systems protection from damage due to freezing, and can be used in residential and commercial applications. The cables automatically adjust heat output according to the ambient temperature conditions. Under cooler conditions the heat output increases, and as the temperature rises the output decreases to save on energy. The cables are available in various pre assembled lengths. Comes in pre cut lengths, seal with cap and plug (120V only) Suitable for plastic or metal gutters and downspouts. suitable for roofs,shingled and metal. will not overheat if overlapped. 240 Volt 120 Volt FSPC Terminated Heat Cable Service Voltage: V V/ V Nominal Cable Width (in/mm) 0.42/10.6 Nominal Cable Thickness (in/mm) 0,23/5.8 Bus Wire Gauge (AWG) Cold Lead Length (in/mm) 16 39/900 Min. Circuit Breaker Size (Amps) 15 Maximum Exposure temperature ( / ) 185/85 Electrical Classification Non Hazardous Chemical Resistance Water And Aqueous Inorganic Chemicals Cable Selection Chart Model 120V/240V Length FSPC1/FSPC2 6 Volt 120/240 Cold Lead Size AWG Power Output on pipe Output on pipe@50 /10 18/18 36 W 30W Output on snow ice@32 / 0 FSPC1/FSPC /240 18/18 72W 60W 120W FSPC1/FSPC /240 18/18 108W 90W 180W FSPC1/FSPC /240 18/18 144W 120W 240W FSPC1/FSPC /240 18/18 225W 187.5W 375W FSPC1/FSPC /240 16/18 300W 250W 500W FSPC1/FSPC /240 16/18 375W 312.5W 625W FSPC1/FSPC /240 16/18 450W 375W 750W FSPC1/FSPC /240 16/18 525W 437.5W 875W FSPC1/FSPC /240 16/16 600W 500W 1000W FSPC1/FSPC /240 14/16 675W 562.5W 1000W FSPC1/FSPC /240 14/16 750W 625W 1250W FSPC1/FSPC /240 14/16 825W 687.5W 1375W FSPC1/FSPC /240 14/16 900W 750W 1500W FSPC W 812.5W 1625W FSPC W 875W 1750W FSPC W 1000W 2000W FSPC W 1125W 2250W FSPC W 1250W 2500W 60W

15 WA-FSPC FSPC - Self Regulating Cable Installation Table 1 Roof Over Hang None 12" 24" 36" 48' A Spacing Factor (ft) B Spacing Factor (in) Shingle Metal Shingle Metal 1,9 2, , ,7 3, ,6 4, ,5 5, FSPC - Self Regulating Cable Installation Choosing the right cable length for pipe tracing Size Type 5 ft 10 ft 15 ft 20 ft 25 ft 30 ft 35 ft 40 ft 45 ft 50 ft 55 ft 60 ft Metal A B C D E E E F F F G G 1/2 Inch 1 Inch 1-1/2 Inch 2 Inch 2-1/2 Inch Plastic A B C E E E E F F F G G Metal A B C D E E E E F F G G Plastic B B C D E E E F F F G G Metal A B C D E E E F F F G G Plastic B C D E E F F G G G H H Metal A B C D E E E F F G G G Plastic B C E F F G G G H H H I Metal A B C E E E E F G G G G Plastic B D E G G G G H I I I J Size Type 65 ft 70 ft 75 ft 80 ft 85 ft 90 ft 95 ft 100 ft 110 ft 120 ft 130 ft 140 ft 150 ft 1/2 Inch 1 Inch 1-1/2 Inch 2 Inch 2-1/2 Inch Metal G G G H H H H H I I J J J Plastic G G G H H H H H I I J J J Metal G G G H H H H H I I J J J Plastic G G H H H H H I I I J J Metal G G G H H H H H I I J J J Plastic H H I I I J J J Metal G G H H H H I I I J J J Plastic I J J Metal G G H H H H I I I J J J Plastic J A B C D E FSPC1 012 FSPC1 018 FSPC1 024 G H I FSPC1 075 FSPC1 100 FSPC1 125 FSPC2 075 FSPC2 100 FSPC2 125 FSPC1 006 F FSPC1 050 FSPC2 050 FSPC1 037 J FSPC1 150 FSPC2 150

16 WA-RDFPIF Ice Free Controller Roof And Gutter Application WA RDFPIF is designed specifically for use with Elec Trace Constant wattage Roof and gutter de icing cable. Designed to sense both temperature and the prensence of run off water, ensuring the heating cable only operates when necessary to prevent ice dams and frozen drains. Both conditions must be met or the system does not run, saving on your energy bill and eliminating waste. Specifically Designed For Elect Trace Cable Sense Both Temperature And Run Off Water Prevent Ice Dams And Frozen Drain Water Resistant Enclosure 120V. Maximum Wattage 1200 W 6 Ft.Cold Lead With Grounded Light Plug Roof And Gutter De-Icing Controller Construction Rated Voltage Max Wattage Application Color Includes Sensor Type Enclosure ABS 120 Volt 1200 Watts Roof/Gutter De Icing Control White Control Unit, Sensor, Shingle Clips Electronic Weather Resistant

17 WA-PSLM-CRT Electric Pipe Heating Cable With Thermostat ET PSLM cable provides freeze protection for pipes in commercial and residential application. Using the latest self regulating technology and a built in thermostat including a pilot indicator showing the presence of power and on/off status, makes these cables both energy efficient and cost effective. These cables are able to adjust their heat output according to the ambient temperature. Electric Pipe Heating Cable With Thermostat Comes in pre cut lengths, with standard 120V/15A cord set. Suitable for use on water filled plastic and metal pipes. Pre Assemble, Ready To Install Cable is built with a tough thermoplastic inner insulation, continuous ground braid and wheather resistant thermoplastic outer Service Voltage 110V 120V Nominal Cable Width (in/mm) Bending Radius (in/mm) / 8 1 / 2.2 Bus Wire (AWG) Cold Lead Length (in/cm) / 61 Min. Circuit Breaker Size (Amps) Maximum Exposure Temperature ( / ) / 40 Electrical Classification Non Hazardous Chemical resistance Water And Aqueous Inorganic Chemicals Thermostat Setting temperature Maximum Switching Current Power Output At 10 /50 On Pipe Cat. Num. ET PSLM CRT1 5 ET PSLM CRT1 10 ET PSLM CRT1 15 ET PSLM CRT1 20 ET PSLM CRT1 35 ET PSLM CRT1 50 ET PSLM CRT1 75 ET PSLM CRT / 38 AC 120V / 12A Voltage Length (ft) Ouput W/ft Output(W) at 10 / Volt Volt Volt Volt Volt Volt Volt Volt

18 WA-SDFP Electric Pipe Heating Cable WA SDFP Pre assemble and ready to install, the cable prevents pipes from freezing, keeping water flowing to 40. Using an energy saving thermostat, ET SDFP cables are suitable for use on water filled plastic and metal pipes. Keeps Water Flowing To 40 Pre Assemble, Ready To Install 2 Ft 18/3 Cold Lead Withgrounded Light Plug With Energy Saving Thermostat Thermostat Located in End Seal Limited Warranty Of 2 Years Electric Pipe Heating Cable Cable Construction: Rated Voltage: Output: Heating Element Size: Bending Radius Conductor Insulation: Outer Insulation: Min. Installation Temp.: Cold Lead: Functions: Supply Voltage: Maximum Switching Current: Setting Temperature: Ambiant Range: Life: Other Twin Conductor 120/240 VAC 7 W/Ft 3 80 Ft 1 Inch 25mm XLPE PVC 10 2 Ft Length 18/3 With Groundeed Light Plug On/Off Control AC 250V Max. AC 120V/12 Amp. AC 240V/10Amp to 105 Standard Use Within 60 Degrees Above The Set Temp. 100,000 Electrical Operations At Rated Load. Cat. Num. Voltage Length Output Total Output Amps Ohms ET SDFP 021W 3 120V 3 7 W 21 0,2 685,7 ET SDFP 042W 6 120V 6 7 W 42 0,4 342,9 ET SDFP 063W 9 120V 9 7 W 63 0,5 228,6 ET SDFP 084W V 12 7 W 84 0,7 171,4 ET SDFP 105W V 15 7 W 105 0,9 137,1 ET SDFP 126W V 18 7 W 126 1,1 114,3 ET SDFP 168W V 24 7 W 168 1,4 85,7 ET SDFP 210W V 30 7 W 210 1,8 68,6 ET SDFP 280W V 40 7 W 280 2,3 51,4 ET SDFP 420W V 60 7 W 420 3,5 34,3 ET SDFP 560W V 80 7 W 560 4,7 25,7

19 WA-5PSL-PW Potable Water Self Regulating Cable NSF/ANSI Standard 61 Potable Water Self Regulating Cable NSF/ANSI Standard 61 WA 5PSL PW is CSA CERTIFIED self regulating parallel heating cable (heating tape) is designed for a variety of potable water applications. It can be used for plastic or metal pipe freeze protection and flow maintenance of pipes, tanks, valves. A UV stabilized thermoplastic elastomer overjacket is provided to cover the braid for wet applications and exposure to the sun. Energy efficient, automatically varies its power output in response to temperature changes. Easy to install, can be cut to any length required on site with no waste. Lower installed cost than steam tracing, less maintenance and downtime. The Fluoropolymer overjacket is NSF/ANSI STANDARD 61 for potable water. Drexma power connection and seal kits will reduce installation time. No overheat or burnout even when overlapped. Maximum length vs circuit breaker size Min. Temperature 10 (50 ) 0 (32 ) CB size 120 Volt 240 Volt Amps Ft M Ft M Cable Construction , , , , , , , , , , , , , ,4 Technical Data , ,6 Service voltage , ,1 Max. maintain , ,9 temperature Power Output Curves Max. intermitent temperature Min. installation temperature Protective braid resistance Bus wire gauge V, V +65 (149 ) +85 (185 ) 40 ( 40 ) <18.2Ω/km 16AWG Pipe Temperature

20 WA-PSLM-8MM 8 mm PSLM Self Regulating Cable WA PSLM cables are ideal for freeze protection & process temperature maintenance on pipe, tanks and valves for residential and commercial applications. These cables use the latest self regulating technology adjusting heat output according to the ambient temperature, making them energy efficient and cost effective. Cable can be cut to desired length and overlapped without risk of overheating. Suitable for metal or plastic surfaces. Lower installation and maintenance cost than steam tracing. Tinned copper braid provides additional protection to the cable core. Flame retardant thermoplastic outer jacket option, protects against certain chemical solution,abrasion and impact damage. 8 mm PSLM Self Regulating Cable Product Number PSL M C For Example: 5PSL M2 CR Jacket Chemical Resistance Nominal Thickness (mm) Nominal Width (mm) Minimum Bending Radius (mm) Weight (kg/100m) Electrical Classification Service Voltage Max. Maintain or Continous Exposure Temperature (power on) Max. Intermitent Exposure Temperature 100 Hours (power on) Minimum Installation Temperature Protective Braid resistance Bus Wire Gauge Outer Jacket R=Thermoplastic Thinned Copper Braid Supply Voltage 1= V / 2= V Type Of Heating Cable Output Power Per Ft At 10 3=3W/ft; 5=5W/ft; 8=8W/ft. PSL M C N/A Moisture 4,1 6, V/ V PSL M CR Thermoplastic Aqueous Inorganic Solutions 5,7 8,3 34 7,5 Non Hazardous V/ V 65 (149 ) 85 (185 ) 40 ( 40 ) <18.2 Ω/km 20 AWG

21 WA-PSLM-8MM PowerOutput Curves At 120V/240V Installed On Insulated Metal Pipes Power output Rating 8 mm PSLM Self Regulating Cable Pipe Temperature Cable Lenght Per Breaker size Start up 120V 240V Temperature 10A 15A 20A 10A 15A 20A 3PSL M PSL M PSL M

22 WA-HTLe-CR-11MM 11 mm HTLe-CR Self Regulating Cable WA HTLe CR cables are ideal for freeze protection & process temperature maintenance on pipe, tanks and valves for residential and commercial applications. These cables use the latest self regulating technology adjusting heat output according to the ambient temperature, making them energy efficient and cost effective. 11 mm HTLe-CR Self Regulating Cable Cable can be cut to desired length and overlapped without risk of overheating. Suitable for metal or plastic surfaces. Lower installation and maintenance cost than steam tracing. Tinned copper braid provides additional protection to the cable core. Flame retardant thermoplastic outer jacket option, protects against certain chemical solution,abrasion and impact damage. Product Number HTLe C For Example: 3HTLe 2 CR Jacket Chemical Resistance Nominal Thickness (mm) Nominal Width (mm) Minimum Bending Radius (mm) Weight (kg/100m) Electrical Classification Service Voltage Max. Maintain or Continous Exposure Temperature (power on) Max. Intermitent Exposure Temperature 100 Hours (power on) Minimum Installation Temperature Protective Braid resistance Bus Wire Gauge Outer Jacket R=Thermoplastic Thinned Copper Braid Supply Voltage 1= V / 2= V Type Of Heating Cable Output Power Per Ft At 10 3=3W/ft; 5=5W/ft; 8=8W/ft; 10=10W/ft. HTLe C N/A Moisture 4,4 9,3 26 9,7 HTLe CR Thermoplastic Aqueous Inorganic Solutions 6 10, Non Hazardous V/ V 65 (149 ) 85 (185 ) 40 ( 40 ) <18.2 Ω/km 16 AWG

23 WA-HTLe-CR-11MM 11 mm HTLe-CR Self Regulating Cable Power output Rating 10 HTLe 8HTLe 5 HTLe 3 HTLe 11 mm HTLe-CR Self Regulating Cable Pipe Temperature Start up 120V 240V Temperature 10A 15A 20A 30A 10A 15A 20A 30A 3 HTLe HTLe HTLe C HTLe HTLe HTLe

24 WA-PSL-13MM 13 mm Self Regulating Cable WA PSL cables are ideal for freeze protection & process temperature maintenance on pipe, tanks and valves for residential and commercial applications. These cables use the latest self regulating technology adjusting heat output according to the ambient temperature, making them energy efficient and cost effective. Cable can be cut to desired length and overlapped without risk of overheating. Suitable for metal or plastic surfaces. Lower installation and maintenance cost than steam tracing. Tinned copper braid provides additional protection to the cable core. Flame retardant thermoplastic outer jacket option, protects against certain chemical solution,abrasion and impact damage. Product Number 13 mm Self Regulating Cable PSL C For Example: 3PSL2 CR Jacket Chemical Resistance Nominal Thickness (mm) Nominal Width (mm) Minimum Bending Radius (mm) Weight (kg/100m) Electrical Classification Service Voltage Max. Maintain or Continous Exposure Temperature (power on) Max. Intermitent Exposure Temperature 100 Hours (power on) Minimum Installation Temperature Protective Braid resistance Bus Wire Gauge Outer Jacket R=Thermoplastic Thinned Copper Braid Supply Voltage 1= V / 2= V Type Of Heating Cable Output Power Per Ft At 10 3=3W/ft; 5=5W/ft; 8=8W/ft; 10=10W/ft; 12=12W/ft. PSL C N/A Moisture 4, , V/ V PSL CR Thermoplastic Aqueous Inorganic Solutions 6 12, ,8 Non Hazardous V/ V 65 (149 ) 85 (185 ) 40 ( 40 ) <18.2 Ω/km 16 AWG

25 WA-PSL-13MM PowerOutput Curves At 120V/ V Installed On Insulated Matel Pipes And Power Ajustment Factors Ajustment factors Power output Rating 208V Power Output Circuit Length 3PSL 0,82 0,96 5PSL 0,85 0,94 0,89 0,92 0,89 0,92 0,89 0,92 Pipe Temperature 8PSL 10PSL 12PSL 277V 3PSL 5PSL 8PSL 10PSL 12PSL 1,13 1,12 1,08 1,08 1,08 1,08 1,09 1,11 1,11 1,11 13 mm Self Regulating Cable Cable Lenght Per Breaker Size Start up Temperature 10A 15A 120V 20A 30A 40A 10A 15A 240V 20A 30A 40A 3 PSL PSL PSL PSL V/ V/ PSL

26

Heating Cables. For Industry Tracing

Heating Cables. For Industry Tracing Heating Cables For Industry Tracing FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length

More information

Heating Cable. Cut to Length in Field. Description

Heating Cable. Cut to Length in Field. Description Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection

More information

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet

More information

Power Connection Kit installation instructions

Power Connection Kit installation instructions Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and

More information

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,

More information

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930 PRODUCT CODES NAMSR-Wattage-Voltage-Length // eg: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly

More information

Self-Regulating Freeze Protection Heating Cable

Self-Regulating Freeze Protection Heating Cable D PDS SRF Self-Regulating Freeze Protection Heating Cable E C B A Output Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Freeze Protection of

More information

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930 PRODUCT CODES NAMSR-Wattage-Voltage-Length. Ex: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly

More information

Electric Heating Product Catalog

Electric Heating Product Catalog Version #: VKAPA922 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage COMFORT and safety solutions for

More information

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket SELF-REGULATING HEATING CABLE For pipe freeze protection and flow maintenance Heating cable construction Tinned-copper braid Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket Modified polyolefin

More information

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt. Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &

More information

Danfoss Electric Heating Products 2012 CATALOG BRINGING WARMTH TO LIFE. Electric Floor Heating

Danfoss Electric Heating Products 2012 CATALOG BRINGING WARMTH TO LIFE. Electric Floor Heating BRINGING WARMTH TO LIFE Electric Floor Heating Electric Snow Melting Roof & Gutter De-Icing Pipe Freeze Protection Thermal Storage PG. 1 PG. 9 PG. 21 PG. 25 PG. 31 Danfoss Electric Heating Products 2012

More information

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife

More information

Self-Regulating Cables

Self-Regulating Cables Self-Regulating 1. Self- Regulating 2. Power- Limiting This step-by-step design guide provides the tools necessary to design a self-regulating heat-tracing system for insulated pipes and tubing. For other

More information

SELF-REGULATING CABLES

SELF-REGULATING CABLES Self-Regulating SELF-REGULATING CABLES This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Electric Heating Product Catalog

Electric Heating Product Catalog Version #: VKAPA522 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage www.heating.danfoss.us Danfoss

More information

Self-regulating cables

Self-regulating cables Self-Regulating Self-regulating cables This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Introduction to Heat Trace Cable Systems

Introduction to Heat Trace Cable Systems Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).

More information

Product Overview. Application

Product Overview. Application Self-Regulating SC, SC/H Series-resistance heating cables for longline systems Electrical freeze protection for long pipelines in both nonhazardous and hazardous locations Power-Limiting Mineral Insulated

More information

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant

More information

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner

More information

Power-Limiting Cables

Power-Limiting Cables Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your

More information

3M Self Regulating Heating Cables

3M Self Regulating Heating Cables 2 Construction & Function 3M Self Regulating Heating Cables Introduction: 3M Canada and Thermon Manufacturing Company have entered into a strategic alliance to market the commercial line of heat tracing

More information

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating

More information

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace pipe freeze protection or flow maintenance system. For

More information

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables... Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss

More information

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Heating systems protect pipes, valves, actuators and other elements vulnerable to harmful influence

More information

FREEZSTOP MICRO SYSTEM

FREEZSTOP MICRO SYSTEM FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 25mm diameter water pipe at +5

More information

INDUSTRIAL HEAT TRACE

INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE www.valin.com 800-774-5630 www.valin.com HTS-6 SERIES The HTS-6 commercial grade heater cable is designed for use in both indoor and outdoor locations as well

More information

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE For commercial and industrial applications Heating cable construction Insulation (magnesium oxide) Heating conductor Copper sheath HDPE

More information

V (For 120, 208, 277, 600 V, please call.) Output: 37 W/ft 2 and 50W/ft 2 Cold lead:

V (For 120, 208, 277, 600 V, please call.) Output: 37 W/ft 2 and 50W/ft 2 Cold lead: Snow Melting Mats Data Sheet GENERAL PRODUCT INFORMATION ProLine snow melting mats feature pre-spaced heat cable (3 and 4-inch spacing) in mats that can be rolled out for quick, easy installation. To make

More information

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system installation guide l 1 Uponor Ecoflex potable PEX plus pre-insulated pipe system

More information

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath Introduction to Heat Trace Cable Systems...6-2 Mineral Insulated Heat Trace Cable...6-2 Non-Metallic Sheath Heat Trace Cable...6-2 Installation Details...6-4 Engineering Guide for Mineral Insulated Cable...6-5

More information

Electric Heating Product Catalog

Electric Heating Product Catalog Version #: VKAPA422 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage www.lx.danfoss.com Danfoss offers

More information

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

Product Catalogue. Worldwide Specialists in Electric Heat Tracing. HTS THERMTRACE HTS THERMTRACE HTS T

Product Catalogue. Worldwide Specialists in Electric Heat Tracing.  HTS THERMTRACE HTS THERMTRACE HTS T Product Catalogue HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE www.hts-global.com is an international operating manufacturer of electric heating

More information

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A

More information

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines PVC jacket - Deg C (optionally PUR material) Glass fibre thermal insulation Process tube(s) Heat reflective tape Electrical heating

More information

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series) PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire

More information

Danfoss LX Electric Floor Heating

Danfoss LX Electric Floor Heating Danfoss LX Electric Floor Heating Electric Floor Heating Thermostats The Danfoss LX Thermostat raises the bar for aesthetic appeal while offering industry-leading functionality. The LX electronic thermostat

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

INSTALLATION GUIDELINES. Design system and make a layout. For guidance, see attached layout and wiring diagram.

INSTALLATION GUIDELINES. Design system and make a layout. For guidance, see attached layout and wiring diagram. INSTALLATION GUIDELINES 1. Plan Design system and make a layout. For guidance, see attached layout and wiring diagram. Heating elements should be placed on top of the ice and water shield. Between the

More information

Self-Regulating Parallel Heating Cables. innovations in heat tracing

Self-Regulating Parallel Heating Cables. innovations in heat tracing Self-Regulating Parallel Heating Cables innovations in heat tracing ELSR Application Options The application options for the ELSR heating cables range from freeze protection to maintenance of pipes and

More information

C A Heating Cable Gland Kit Installation Instructions

C A Heating Cable Gland Kit Installation Instructions C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation

More information

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A

More information

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

Heat Tracing Products

Heat Tracing Products Applications Electric Industrial Process Maintenance Applications Commercial Applications Chromalox heating cable line includes cables suitable for most process maintenance, pipe and vessel freeze protection

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

Snow Melting Mats Price Sheet

Snow Melting Mats Price Sheet Snow Melting Mats Price Sheet EFFECTIVE : 201 WarmlyYours Snow Melting Mats are available in a variety of sizes and voltages to meet your requirements. The following pricing guide has been designed to

More information

H900 WinterGard Power Connection Kit with End Seal Installation Instructions

H900 WinterGard Power Connection Kit with End Seal Installation Instructions H900 WinterGard Power Connection Kit with End Seal Installation Instructions Power connection for H311, H611, and H621 Power connection for H612 and H622 Description The WinterGard power connection kit

More information

37T Series Moisture Resistant Temperature Controls

37T Series Moisture Resistant Temperature Controls 37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a

More information

MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration

MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration MI Heating Cable HDPE jacketed, copper sheathed MI cable For surface snow melting in concrete, asphalt, and pavers Pipe Freeze Protection and Flow Maintenance Fire Sprinkler System Freeze Protection MI

More information

Self-regulating heating cables with a non-heating service cable

Self-regulating heating cables with a non-heating service cable N144/R02(22.08.18) Self-regulating heating cables with a non-heating service cable ELSR-M-15-2-BO ELSR-N--2-AO ELSR-N-30-2-AO GENERAL CONDITIONS The connector which connects the cold end and the heating

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) 1.0 SCOPE This specification outlines the minimum requirements for electrically traced or steam/fluid traced instrument

More information

Pipe Freeze Protection Design/Install Guide

Pipe Freeze Protection Design/Install Guide Pipe Freeze Protection Design/Install Guide Page 1 of 16 Pipe Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 STEP 1 Information Required Page 4 STEP 2 Design Considerations Page

More information

ELSR Electric Self-Regulating Parallel Heating Cables

ELSR Electric Self-Regulating Parallel Heating Cables ELSR Electric Self-Regulating Parallel Heating Cables www.hazlocheaters.com www.eltherm.ca 1 Eltherm, a German manufacturer, and Hazloc Heaters (part of The Ouellet Canada Group) have formed a strategic

More information

CAPABILITIES EXPERT TECHNICAL SUPPORT

CAPABILITIES EXPERT TECHNICAL SUPPORT Heat Trace Systems CAPABILITIES HEAT TRACE SOLUTIONS Cables Controllers Sensors Accessories EXPERT TECHNICAL SUPPORT Chromalox heat trace products and services save you time, reduce the cost of ownership,

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

Heating Cable. Construction

Heating Cable. Construction Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

Heating Cable. Description

Heating Cable. Description 203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal building solutions WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions SRK02 Hard Wire Power Connection Kit Installation, Operation and Maintenance Instructions IMPORTANT: Save These Instructions! Item Qty Description A 1 Black heat shrink tube (1/2 dia. x 1 length) B 2 Black

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1). R AMG-BC-III AutoMatrix Power Connection Kit Description The AMG-BC-III is a copper free aluminum (maximum 4/10 of 1% copper) NEMA 4X (1) rated power connection kit for single or dual heating cable entry.

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Heating Cable. Construction

Heating Cable. Construction MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)

More information

HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS CLOSED- AND OPEN-LOOP CONTROL SYSTEMS HEATERS WATER LEAKAGE DETECTION SYSTEMS

HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS CLOSED- AND OPEN-LOOP CONTROL SYSTEMS HEATERS WATER LEAKAGE DETECTION SYSTEMS HEATING TECHNOLOGY HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS 1 CLOSED- AND OPEN-LOOP CONTROL SYSTEMS 2 HEATERS 3 WATER LEAKAGE DETECTION SYSTEMS 4 PROJECT PLANNING INFORMATION 5 CONTENT

More information

Heating Cables Heating Tapes. innovations in heat tracing

Heating Cables Heating Tapes. innovations in heat tracing Heating Cables Heating Tapes innovations in heat tracing Table of Contents Introduction 3 Type ELP/SI Constant Wattage Heating Cable up to 200 C 4-5 Type ELP/SI-F Constant Wattage Heating Cable up to 200

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022

More information

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10) A/C Disconnects 60 amps Non-fused. 240v A.C. Single Phase. UL Listed Three piece construction that opens up mounting and wiring areas, reduces installation time. Terminals approved for 60*C and 75*C wire.

More information

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.

More information

Solutions in Rail Heating Systems. Rail Heating Proposal. Innovations in heat tracing

Solutions in Rail Heating Systems. Rail Heating Proposal. Innovations in heat tracing Solutions in Rail Heating Systems Rail Heating Proposal Innovations in heat tracing Innovations in heat tracing eltherm our company How can we protect antennas from ice in frosty weather? How can we transport

More information

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions JBM-100-STB NEMA 4X-rated connection kit Installation Instructions Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box Approvals Hazardous Locations CLI,

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

PRODUCT NAME ORDER # PAGE # ANTENNAS

PRODUCT NAME ORDER # PAGE # ANTENNAS PRODUCT NAME ORDER # PAGE # ANTENNAS 890-960 Yagi Antenna UBR-Y9000 w/ lead 0580 450 Mhz Yagi Antenna UBR-Y4000 w/ lead 05803 806-960 & 70-990 MHz Dual Band Omni Antenna 09835 3 806-960 & 70-500 Yagi Multiband

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

THERMOCOUPLE CABLES THERMOELECTRICITY

THERMOCOUPLE CABLES THERMOELECTRICITY THERMOCOUPLE CABLES THERMOELECTRICITY When a metallic conductor is exposed to a difference of temperature between the two extremities, an electromotive force (emf) is generated by the temperature gradient,

More information

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating

More information

RMP SERIES INFORMATION GUIDE

RMP SERIES INFORMATION GUIDE RMP SERIES INFORMATION GUIDE DESCRIPTION & DESIGN FEATURES Applications RMP series connectors can be used wherever high amperage connection of AC or DC power is required. Typical applications are the connection

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68

More information