ELSR Electric Self-Regulating Parallel Heating Cables

Size: px
Start display at page:

Download "ELSR Electric Self-Regulating Parallel Heating Cables"

Transcription

1 ELSR Electric Self-Regulating Parallel Heating Cables 1

2 Eltherm, a German manufacturer, and Hazloc Heaters (part of The Ouellet Canada Group) have formed a strategic alliance in North America to market the commercial and industrial line of self-regulating heat tracing products manufactured by eltherm. Hazloc Heaters and Ouellet Canada will exclusively offer eltherm s superior line of selfregulating (ELSR) heat tracing products through its extensive network of sales partners throughout Canada and the United States. ELSR Application Options The application options for the ELSR heating cables range from freeze protection to maintenance of pipes and vessels. The eltherm ELSR-NA heating cable is suitable for low and medium applications, a high version ELSR-HA heating cable is available for s up to 392 F (200 C). Matching accessories complete our product offering. All eltherm heating cables have been approved by national and international technical standards (e.g. VDE). ELSR-NA, ELSR- HA, ELSR-WA heating cables are also approved and certified for use in hazardous areas. Design: 4 distinct options We offer the widest selection of self-regulating heating cable designs, capable of handling every application, including service in harsh conditions and corrosive environments. AO: Aluminum foil with a thermoplastic outer jacket This design allows for easy assembly. AO design is available for all low and medium heating cables. BO: Protective braid with a thermoplastic outer jacket This classic design provides a protective tin-plated copper braid. The BO design is available for low and medium heating cables. BOT: Protective braid with fluoropolymer outer jacket This design features a fluoropolymer outer jacket to provide maximum resistance to aggressive chemicals, oil and fuel. The BOT outer jacket design is available for various ELSR-heating cables. BF: Protective braid with food approved outer jacket, approved for use in potable water A heating cable of this design can be used directly inside potable water lines. This design is currently only available for the ELSR-MA version. Most products listed in this catalog are available for use in hazardous locations, please review the individual product data sheets for details on use in hazardous locations. The s allocated to the products are the maximum permissible exposure s. Our project engineers will be glad to assist you to design and dimension electrical heating systems. All products listed in the catalog are available ex stock (subject to prior sale). Please note: All products listed in this catalog shall only be connected and commissioned by a qualified electrician. All applicable local electrical and safety regulations must be observed during installation and operation. For most economic design and accurate maintain applications we recommend the use of a control unit National and international electrical codes require the use of residual current devices (RCDs) or ground-fault circuit interrupters (GFCIs) to separate in time electrical heating from mains supply to prevent damage. Specifications and advertising messages in this products and services catalog, irrespective of their nature, in particular descriptions, illustrations, drawings, samples, information pertaining to quality, condition, composition, performance, consumption and usability as well as dimensions and weights of the product range remain subject to change in as far as they are not expressly declared as binding. They do not denote any assurance or guarantee whatsoever. Minor deviations from the product specifications shall be deemed approved in as far as they are not unreasonable for the buyer. We explicitly reserve the right to amend errors and alter technical data. 2 2 Self-Regulating Heating Heating Cable Cable

3 Self-Regulating Parallel Heating Cables Benefits: Benefits: Application: Operation: with with adaptable adaptable output output Various Various range range applications High High chemical chemical resistance resistance No No regulation regulation or or limiting limiting required required Easy Easy to install to install Can Can be cut be to cut length to length off the off roll the roll Features The The ELSR ELSR heating heating cable cable (eltherm (eltherm heating heating cables cables consist consist -self-regulating) can can be used be used for freeze for freeze of two of two parallel parallel bus bus wires wires embedded in in protection protection and and maintaining constant constant a networked a plastic plastic heating heating element, element, s on vessels, on vessels, pipes, pipes, valves, valves, doped doped with with surrounding carbon carbon particlescles. If the If the increases increases during during heating heating cable cable may may be immersed be immersed in in operation, operation, the the plastic plastic expands expands due due to to fluids. fluids. If used If used in an in aggressive an aggressive environ- environ- molecular molecular expansion expansion and and the distance the distance ment ment (the (the chemical chemical or petrochemical or between between the carbon the carbon particles particles increases. increases. industry), industry), we lag we the lag heating the heating cable cable with with Resistance Resistance increases increases and and output output drops. drops. a special a special chemically resistant resistant outer outer When When it cools it cools down, down, this this process process is re-is re- jacket jacket (fluoropolymer), option option BOT. BOT. versed versed and and output output increases. increases. This This physical physical property property provides provides several several benefits, benefits, including including the ability the ability to overlap to overlap the self-regulating the cable cable and and installation installation without without the requirement the of a of tempera- a temperaturture cut-out cut-out device. parti- etc.. etc.. Except Except for the for the connections, the the device. Type Type ELSR-NA-AO ELSR-NA-AO Moisture proof Moisture proof UV-resistant UV-resistant Highest chemical resistance Highest chemical resistance Physical contact with foodstuffs/ Physical use in potable contact with water foodstuffs/ use in potable water Low Low Medium Medium High High Approved for hazardous areas Approved for hazardous areas ELSR-NA-BO ELSR-NA-BO ELSR-NA-BOT ELSR-MA-AO ELSR-MA-BO ELSR-MA-BF ELSR-MA-BF ELSR-WA-AO ELSR-WA-BO ELSR-HA-BOT Self-Regulating Heating Heating Cable Cable 3 3

4 Heating Cable Self-Regulating eltherm s eltherm s ELSR-NA ELSR-NA line line of self-regulating of heating heating cables cables are designed are designed for freeze for freeze protection and and process process maintenance up to up 140 to 140 F (0 F C) (0 and C) and are suitable are suitable for a for wide a wide range range of commercial of and and industrial industrial applications. The The NA NA series series of heat of heat tracers tracers are approved are for use for use in non-hazardous in and and hazardous locations. The The BOT BOT version version of the of the heat heat tracer tracer is configured is for use for use in corrosive in corrosive environments, including organic organic chemicals and and corrosives found found in the in the oil, oil, gas, gas, and and petrochemical industry. industry. Advantages: Multiple Multiple nominal nominal outputs outputs May May be cut be cut to length to length in the in the field field Weather Weather Resistant Resistant UV-resistant Approved for use for use in hazardous in areas areas Applications: Freeze Freeze protection Heat Heat tracing tracing of instrumentation of Pipes, Pipes, vessel vessel and and tanks tanks Chemical Chemical and and petrochemical industries Oil and Oil and gas gas industries Food Food processing Automotive Tank Tank bottom bottom heating/frost heave heave prevention of LNG of LNG and and cryogenic terminal terminal storage storage tanks tanks Type ELSR-NA Protective braid Cu, tin plated Bus wire heating element Insulation Outer jacket Protective conductor Cu, tin plated Protection aluminum foil 4 Self-Regulating Heating Cable

5 Technical Information Type ELSR-NA Data Heating cable Outer jacket Bus wire Nominal output 208 V vs. 240 V Thermoplastic / Fluoropolymer Nickel plated copper Minimum start up -22 F (-30 C) Maximum operating, energized Maximum operating, de-energized Nominal voltage Bending radius, min. Installation, min. 140 F (0 C) 17 F (80 C) 120 VAC (ELSR-NA-XX-1-XX) 240 VAC (ELSR-NA-XX-2-XX) 25 mm (1 in) -49 F (-45 C) Classification Class I Div 1* Group B,C,D Class I Div 2 Group A,B,C,D Class II Div 2 Group E,F,G Class III T Class I Zone1 Ex e II T *with termination kit Hazelect (item no. 09CA051); Canada only Certificates CSA C US Standards IEEE 515, CSA Rating Wet rated, for outdoor use (WS) Heating circuit length 208 V vs. 240 V ELSR-NA-XX Design BO AO Type BOT Protective braid and a thermoplastic outer jacket Aluminum foil and a thermoplastic outer jacket Protective braid and a fluoropolymer outer jacket Nominal output Dimensions (mm) Weight (g/m) Item No. ELSR-NA-3-1-AO 3 W/ft at 41 F (5 C) 13. x BA ELSR-NA-3-1-BO 3 W/ft at 41 F (5 C) 14.1 x BA ELSR-NA-3-1-BOT 3 W/ft at 41 F (5 C) 13.8 x 5. 8 BA ELSR-NA-4-2-AO 4 W/ft at 41 F (5 C) 13. x BA ELSR-NA-4-2-BO 4 W/ft at 41 F (5 C) 14.1 x BA2001 ELSR-NA-4-2-BOT 4 W/ft at 41 F (5 C) 13.8 x 5. 8 BA ELSR-NA-5-1-AO 5 W/ft at 41 F (5 C) 13. x BA ELSR-NA-5-1-BO 5 W/ft at 41 F (5 C) 14.1 x BA ELSR-NA-5-1-BOT 5 W/ft at 41 F (5 C) 13.8 x 5. 8 BA ELSR-NA--2-AO W/ft at 41 F (5 C) 13. x BA ELSR-NA--2-BO W/ft at 41 F (5 C) 14.1 x BA2002 ELSR-NA--2-BOT W/ft at 41 F (5 C) 13.8 x 5. 8 BA ELSR-NA-7-1-AO 7 W/ft at 41 F (5 C) 13. x BA ELSR-NA-7-1-BO 7 W/ft at 41 F (5 C) 14.1 x BA ELSR-NA-7-1-BOT 7 W/ft at 41 F (5 C) 13.8 x 5. 8 BA ELSR-NA-8-2-AO 8 W/ft at 41 F (5 C) 13. x BA ELSR-NA-8-2-BO 8 W/ft at 41 F (5 C) 14.1 x BA2003 ELSR-NA-8-2-BOT 8 W/ft at 41 F (5 C) 13.8 x 5. 8 BA ELSR-NA--2-AO W/ft at 41 F (5 C) 13. x BA ELSR-NA--2-BO W/ft at 41 F (5 C) 14.1 x BA2004 ELSR-NA--2-BOT W/ft at 41 F (5 C) 13.8 x 5. 8 BA Self-Regulating Heating Cable 5

6 Heating Circuit Length Type ELSR-NA 120 VAC 240 VAC 50 F ( C) 32 F (0 C) 14 F (- C) -22 F (-30 C) CB capacity (A) Maximum heating circuit length (ft) for Start-up ELSR-NA- 3-1 ELSR-NA- 5-1 ELSR-NA F ( C) 32 F (0 C) 14 F (- C) -22 F (-30 C) CB capacity (A) Maximum heating circuit length (ft) for Start-up ELSR-NA- 4-2 ELSR-NA- -2 ELSR-NA- 8-2 ELSR-NA Maximum heating circuit lengths ELSR-NA-XX based on the following conditions: Voltage 120VAC (-1-) / 240VAC (-2-) MCB type QO (0% utilisation) Voltage drop max. % Single cable fed from 1 end ELSR-NA-XX-1-XX output (on insulated metallic pipes) ELSR-NA-XX-2-XX output (on insulated metallic pipes) ELSR-NA-7-1-XX ELSR-NA-5-1-XX ELSR-NA-3-1-XX ELSR-NA--2-XX ELSR-NA-8-2-XX ELSR-NA--2-XX ELSR-NA-4-2-XX -22 ( 30) -4 ( 20) 14 ( ) 32 (0) 50 () 8 (20) 8 (30) 4 (40) 122 (50) 140 (0) -22 ( 30) -4 ( 20) 14 ( ) 32 (0) 50 () 8 (20) 8 (30) 4 (40) 122 (50) 140 (0) Pipe F / ( C) Pipe F / ( C) Self-Regulating Heating Heating Cable Cable

7 Heating Cable High Temperature Self-Regulating eltherm s eltherm s ELSR-HA ELSR-HA line line of of self-regulating heating heating cables cables are designed are designed for high for high process process maintain maintain applicationcations up to up 392 to 392 F (200 F (200 C) and C) and are suitable are suitable for a for wide a wide range range of industrial of industrial service. service. The The HA series HA series of heating of heating cables cables appli- are approved are approved for use for use in in non-hazardous and and hazardous locations. locations. The The materials materials of of construction chosen chosen for the for -HA the -HA series series cable cable provides provides maximum protection for service for service in the in the harshest harshest environments, including including organic organic chemicals chemicals and and corrosives corrosives found found in the in oil, the gas oil, and gas and petrochemical industry. industry. Advantages: Applications: Maximum maintain maintain F (120 F (120 C) C) Freeze Freeze protection Maximum exposure exposure F (200 F (200 C) C) Heat Heat tracing tracing of of instrumentation Pipes, Pipes, vessel vessel and and tanks tanks Various Various nominal nominal outputs outputs available available Chemical Chemical and and petrochemical industries industries May May be cut be to cut length to length in the in field the field Oil and Oil and gas industries gas industries Moisture Moisture proof proof Food Food processing Highly Highly resistant resistant to chemicals to chemicals and and Automotive corrosive corrosive environments Tank Tank bottom bottom heating/frost heave heave protection Approved Approved for use for use in in hazardous areas areas of LNG of LNG and and cryogenic cryogenic terminal terminal storage storage tanks tanks Type ELSR-HA Bus wire heating element Insulation Protective braid, tinned copper Outer jacket Self-Regulating Heating Cable 7

8 Technical Information Type ELSR-HA Data Outer jacket Bus wire Fluoropolymer Nickel plated copper Minimum start up -22 F (-30 C) Maximum operating, energized Maximum operating, de-energized Nominal voltage Bending radius, min. Installation, min. 248 F (120 C) 302 F (150 C), continuous, 392 F (200 C) de-energized, for 00 h cumulative 120 VAC (ELSR-HA-XX-1-BOT) 240 VAC (ELSR-HA-XX-2-BOT) 25 mm (1 in) -49 F (-45 C) Classification Class I Div 1* Group B,C,D Class I Div 2 Group A,B,C,D Class II Div 2 Group E,F,G Class III T3 Class I Zone1 Ex e II T3 *with termination kit Hazelect (item no. 09CA051); Canada only Certificates CSA C US Standards IEEE 515, CSA Rating Wet rated, for outdoor use (WS) Design Type BOT Protective braid and a fluoropolymer outer jacket Nominal output Dimensions (mm) Weight (g/m) Item No. ELSR-HA-3-1-BOT 3 W/ft at 50 F ( C) 12.4 x BA2211 ELSR-HA-3-2-BOT 3 W/ft at 50 F ( C) 12.4 x BA2213 ELSR-HA-7-1-BOT 7 W/ft at 50 F ( C) 12.4 x BA ELSR-HA-7-2-BOT 7 W/ft at 50 F ( C) 12.4 x BA ELSR-HA--1-BOT W/ft at 50 F ( C) 12.4 x BA ELSR-HA--2-BOT W/ft at 50 F ( C) 12.4 x BA ELSR-HA-15-1-BOT 15 W/ft at 50 F ( C) 12.4 x BA ELSR-HA-15-2-BOT 15 W/ft at 50 F ( C) 12.4 x BA ELSR-HA-20-1-BOT 20 W/ft at 50 F ( C) 12.4 x BA221 ELSR-HA-20-2-BOT 20 W/ft at 50 F ( C) 12.4 x BA223 Heating cable Nominal output 208 V vs. 240 V Heating circuit length 208 V vs. 240 V ELSR-HA-XX Self-Regulating Heating Cable

9 Heating Circuit Length Type Type ELSR-HA VAC VAC VAC VAC Start-up Start-up CB capacitpacity CB ca- Maximum Maximum heating heating circuit circuit length length (ft) for (ft) for Start-up Start-up CB ca- CB ca- Maximum Maximum heating heating circuit circuit length length (ft) for (ft) for ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA-tempe- tempepacitpacity ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- ELSR-HA- temperaturrature (A) (A) rature rature (A) (A) tempe F50 F 50 F50 F ( C) ( C) ( C) ( C) F32 F 32 F32 F (0 C) (0 C) (0 C) (0 C) F14 F 14 F14 F (- C) (- C) (- C) (- C) F-22 F -22 F-22 F (-30 C) (-30 C) (-30 C) (-30 C) Maximum Maximum heating heating circuit circuit lengths lengths ELSR-HA-XX based based on the on following the following conditions: conditions: Voltage Voltage 120VAC 120VAC (-1-) /(-1-) 240VAC / 240VAC (-2-) (-2-) MCB MCB type type QO (0% QO (0% utilisation) utilisation) Voltage Voltage drop drop max. max. % % Single Single cable cable fed from fed from 1 end1 end ELSR-HA-XX-1-BOT output output (on insulated (on insulated metallic metallic pipes) pipes) ELSR-HA-XX-2-BOT output output (on insulated (on insulated metallic metallic pipes) pipes) ELSR-HA-20-2-BOT ELSR-HA-20-2-BOT ELSR-HA-20-1-BOT ELSR-HA-20-1-BOT ELSR-HA15-1-BOT ELSR-HA15-1-BOT 15 ELSR-HA--1-BOT ELSR-HA--1-BOT 15 ELSR-HA15-2-BOT ELSR-HA15-2-BOT 15 ELSR-HA--2-BOT ELSR-HA--2-BOT 5 ELSR-HA-7-1-BOT ELSR-HA-7-1-BOT 5 ELSR-HA-3-1-BOT ELSR-HA-3-1-BOT 5 ELSR-HA-7-2-BOT ELSR-HA-7-2-BOT 5 ELSR-HA-3-2-BOT ELSR-HA-3-2-BOT ( 40) ( 40) ( 20) ( 20)(0) 32 8 (0) (20) 8 4 (20)(40) 4140 (40)(0) (0)(80) (80) (0) (0) (120) 248 (120) ( 40) ( 40) ( 20) ( 20)(0) 32 8 (0) (20) 8 4 (20)(40) 4140 (40)(0) (0)(80) (80) (0) (0) (120) 248 (120) Pipe Pipe F / ( C) F / ( C) Pipe Pipe F / ( C) F / ( C) Self-Regulating Heating Heating Cable Cable 9 9

10 Heating Cable Medium Temperature, Self-Regulating eltherm s eltherm s ELSR-WA ELSR-WA self-regulating heating heating cable cable is suitable is suitable for heat for heat tracing tracing of vessels, of vessels, pipes, pipes, valves valves and and other other applications in medium in medium ranges ranges between between 85 to to 175 F (30 F to (3080 to C). 80 C). ELSR-WA ELSR-WA heating heating cables cables are are ap- frequently used used to heat to heat trace trace process process and and drain drain lines lines the in the food food processing industry, industry, or to or maintain to maintain s in hot in hot water water supply supply lines lines of large of large commercial buildings. ELSR-WA ELSR-WA is approved is for use for use in hazardous in locations, making making it ideally it ideally suited suited for medium for medium service service for various for various industrial industrial applications. Advantages: Available Available in two in two nominal nominal outputs outputs Can Can be cut be cut to length to length off the off the spool spool Water Water proof proof Applications: Food Food processing industry industry Drain Drain lines lines canteens in canteens and and large-scale kitchens kitchens Freeze Freeze protection of heated of heated lines lines or pipes or pipes Installation of hot of hot water water supplies supplies Type ELSR-WA Protective braid tinned copper Bus wire heating element Insulation Outer jacket Protective conductor Cu, tin plated Protection aluminum foil Self-Regulating Heating Cable

11 Technical Information Type ELSR-WA Data Design Outer jacket TPE-O BO Protective braid and a thermoplastic outer jacket Bus wire Nickel plated copper AO Aluminum foil and a thermoplastic outer jacket Minimum start up -22 F (-30 C) Maximum exposure (power off) Maximum exposure (power on) Nominal voltage Bending radius, minimum Installation, min. Classification 194 F (90 C) 17 F (80 C) 120 VAC (ELSR-WA-XX-1-XX) 240 VAC (ELSR-WA-XX-2-XX) 20 mm (0.79 in) -49 F (-45 C) Class I Zone 1 AEx / Ex e II T5 Class I Div 2 Group A, B, C, D Class II Div 1 Group E, F, G Class III Div 1 Certificates FM CUS Type Nominal output used for water supply lines Dimensions (mm) Weight (g/m) Item No. ELSR-WA-55-1 AO 3 W/ft at 131 F (55 C) 13.4 x BA20030 ELSR-WA-55-1 BO 3 W/ft at 131 F (55 C) 13. x BA ELSR-WA-55-2 AO 3 W/ft at 131 F (55 C) 13.4 x BA ELSR-WA-55-2 BO 3 W/ft at 131 F (55 C) 13. x BA ELSR-WA-5-1 AO 4 W/ft at 149 F (5 C) 13.4 x BA20040 ELSR-WA-5-1 BO 4 W/ft at 149 F (5 C) 13. x BA ELSR-WA-5-2 AO 4 W/ft at 149 F (5 C) 13.4 x BA ELSR-WA-5-2 BO 4 W/ft at 149 F (5 C) 13. x BA Standards IEEE 515, CSA Rating Wet rated, for outdoor use (WS) Heating cable Nominal output 208 V vs. 240 V Heating circuit length 208 V vs. 240 V ELSR-WA-XX Type Nominal output used with fat/ oil lines Dimensions (mm) Weight (g/m) Item No. ELSR-WA-5-2 AO 7 W/ft at 4 F (40 C) 13.4 x BA ELSR-WA-5-2 BO 7 W/ft at 4 F (40 C) 13. x BA ELSR-WA-5-1 AO 7 W/ft at 4 F (40 C) 13.4 x BA20040 ELSR-WA-5-1 BO 7 W/ft at 4 F (40 C) 13. x BA Self-Regulating Heating Cable 11

12 Heating Circuit Length Type ELSR-WA 120 VAC 240 VAC Start-up 50 F ( C) 32 F (0 C) 14 F (- C) -22 F (-30 C) CB capacity (A) Heating circuit length (ft) for ELSR-WA-55-1 ELSR-WA Start-up 50 F ( C) 32 F (0 C) 14 F (- C) -22 F (-30 C) CB capacity (A) Heating circuit length (ft) for ELSR-WA-55-2 ELSR-WA Heating circuit lengths ELSR-WA-XX based on the following conditions: Voltage 120VAC (-1-) / 240VAC (-2-) MCB type QO (0% utilisation) Voltage drop max. % Single cable fed from 1 end ELSR-WA-XX-1-XX output (on insulated metallic pipes, in accordance with IEEE 515/CSA ) ELSR-WA-XX-2-XXoutput (on insulated metallic pipes, in accordance with IEEE 515/CSA ) (-40) -22 ( 30) -4 ( 20) 14 ( ) (0) ELSR-WA-55-1-XX -1-XX 50 () ELSR-WA-5-1-XX 8 (20) Pipe F / ( C) 8 (30) 4 (40) 122 (50) 140 (0) 158 (70) 17 (80) 40 (-40) -22 ( 30) -4 ( 20) 14 ( ) (0) ELSR-WA-5-2-XX ELSR-WA-55-2-XX () 8 (20) Pipe F / ( C) 8 (30) 4 (40) 122 (50) 140 (0) 158 (70) 17 (80) 12 Self-Regulating Heating Cable

13 Heating Cable Micro Self-Regulating eltherm s ELSR-MA self-regulating heating cable is extremely flexible and designed for installations which require smaller overall cable dimensions and shorter heating circuits. ELSR-MA is suitable for freeze protection and maintain applications to 140 F (0 C). Advantages: Two nominal outputs Cut to length off the spool Moisture proof UV-resistant Small dimensions Applications: Heat tracing of metallic and non-metallic pipes, pumps, vessels and valves Food processing industry Automotive Refrigeration Sprinkler systems Sewage pipes, intake drain pipes Type ELSR-MA Protective braid tinned copper Bus wire heating element Insulation Outer jacket Protective conductor copper tin plated Protection aluminum foil Self-Regulating Heating Cable 13

14 Technical Information Type ELSR-MA Data Design Outer jacket TPE-O BO Protective braid and a thermoplastic outer jacket Bus wire Nickel plated copper AO Aluminum foil and a thermoplastic outer jacket Minimum start up -22 F (-30 C) Maximum operating de-energized Maximum operating energized Nominal voltage Bending radius, minimum Installation, min. 140 F (0 C) 140 F (0 C) 120 VAC (ELSR-MA-XX-1-XX) 240 VAC (ELSR-MA-XX-2-XX) 25 mm (1 in) -49 F (-45 C) Standards IEEE 515, CSA Certificates FM CUS Rating Wet rated, for outdoor use (WS) Type Nominal output Dimensions (mm) Weight (g/m) Item No. ELSR-MA-3-1 AO 3 W/ft at 50 F ( C) 7.7 x.4 2 BA2251 ELSR-MA-3-1 BO 3 W/ft at 50 F ( C) 8.1 x BA ELSR-MA-3-2 AO 3 W/ft at 50 F ( C) 7.7 x.4 2 BA ELSR-MA-3-2 BO 3 W/ft at 50 F ( C) 8.1 x BA ELSR-MA-5-1 AO 5 W/ft at 50 F ( C) 7.7 x.4 2 BA2252 ELSR-MA-5-1 BO 5 W/ft at 50 F ( C) 8.1 x BA ELSR-MA-5-2 AO 5 W/ft at 50 F ( C) 7.7 x.4 2 BA ELSR-MA-5-2 BO 5 W/ft at 50 F ( C) 8.1 x BA Self-Regulating Heating Cable

15 Heating Circuit Length Type ELSR-MA 120 VAC 240 VAC Start-up 50 F ( C) 32 F (0 C) 14 F (- C) -22 F (-30 C) CB capacity (A) Heating circuit length (ft) for ELSR-MA-3-1 ELSR-MA Start-up 50 F ( C) 32 F (0 C) 14 F (- C) -22 F (-30 C) CB capacity (A) Heating circuit length (ft) for ELSR-MA-3-2 ELSR-MA Heating circuit lengths ELSR-MA-XX based on the following conditions: Voltage 120VAC (-1-) / 240VAC (-2-) MCB type QO (0% utilisation) Voltage drop max. % Single cable fed from 1 end ELSR-MA-XX-1-XX output (on insulated metallic pipes, in accordance with IEEE 515/CSA ) ELSR-MA-XX-2-XX output (on insulated metallic pipes, in accordance with IEEE 515/CSA ) ELSR-MA-5-1-XX X ELSR-MA-5-1-XX ELSR-MA-3-1-XX ELSR-MA-3-1-XX ELSR-MA-5-2-XX ELSR-MA-5-2-XX ELSR-MA-3-2-XX -3 X ELSR-MA-3-2-XX (-40) -22 ( 30) -4 ( 20) 14 ( ) 32 (0) 50 () 8 (20) 8 (30) 4 (40) 122 (50) 140 (0) 40 (-40) ( (-40) 30) ( 30) 20) ( 20) ) ( (0) ) (0) () 50 8 () (20) 8 8 (20) (30) 4 8 (30) (40) (40) (50) (50) (0) 140 (0) Pipe F / ( C) Pipe F / ( C) Self-Regulating Heating Cable 15

16 Heating Cable Micro for use in Potable Water eltherm s ELSR-MA-BF is a light construction self-regulating heating cable specifically designed and approved for heat tracing of potable water lines. ELSR-MA-BF provides maximum performance in a most compact design and is optimized for short heating circuits for the most economical operation. This versatile heating cable comes with an NSF compliant outer jacket for installation inside of potable water pipelines. Advantages: NSF compliant Can be cut to length off the spool Moisture proof UV-resistant Small dimensions Application: Internal trace heating for pipes and hoses Type ELSR-MA-BF Bus wire heating element Insulation Protective braid, tinned copper NSF compliant outer jacket 1 Self-Regulating Heating Cable

17 Technical Information Type ELSR-MA-BF Data Outer jacket Bus wire Minimum start up Maximum exposure (power off) Maximum exposure (power on) Nominal voltage Bending radius, minimum Installation, min. Fluoropolymer Nickel plated copper -22 F (-30 C) 140 F (0 C) 140 F (0 C) 120 VAC (ELSR-MA-3-1-BF) 240 VAC (ELSR-MA-3-2-BF) 25 mm (1 in) -49 F (-45 C) Standards IEEE 515, CSA Certificates FM CUS Rating PS (2,000 kpa / 290 psi) Design BF Type Protective braid and outer jacket, suitable for use in potable water (certified according to NSF/ANSI 1) Nominal output Dimensions (mm) Weight (g/m) Item No. ELSR-MA-3-1 BF 3 W/ft at 50 F ( C) 8.1 x BA ELSR-MA-3-2 BF 3W/ft at 50 F ( C) 8.1 x BA225 Heating Circuit Length (immersed) 120 VAC 240 VAC Start-up 50 F ( C) 32 F (0 C) CB capacity (A) Heating circuit length (ft) for ELSR-MA-3-1-BF Start-up 50 F ( C) 32 F (0 C) CB capacity (A) Heating circuit length (ft) for ELSR-MA-3-2-BF Heating circuit lengths ELSR-MA-XX-BF based on the following conditions: Voltage 120VAC (-1-) / 240VAC (-2-) Voltage drop max. % MCB type QO (0% utilisation) Single cable fed from 1 end ELSR-MA-3-X-BF output (in a filled water pipeline) 7 ELSR-MA-3-XX-BF (0) 35, (2) 39,2 (4) 42,8 4, , 57,2 () (8) () (12) (14) Ambient F / ( C) 0,8 (14) 4,4 (18) 8 (20) Self-Regulating Heating Cable 17

18 Self-Regulating Heating Cables Accessories Designation Description Item No. Possible combinations of heating cable and kit Power Connection Kits ELSR-HA (-WS) ELSR-NA (-WS) ELSR-HA, Ex Zone 1, Div 2, Class I, II, III, Div 2 ELSR-NA, Ex Zone 1, Div 2, Class I, II, III, Div 2 ELSR-MA ELSR-MA-BF ELSR-WA (-WS) ELSR-WA, Ex Zone 1, Div 2, Class I, II, III, Div 2 Power Connection Kit ELSR-HA, -NA with nickel plated ELVB-SREx-3/4" BR HT cable gland, 3/4" NPT (hazardous location) 09CA007 ELVB-SREx-3/4" BR HT Power Connection Kit ELSR-WA with nickel plated cable gland, 3/4" NPT (hazardous location) 09CA027 ELVB-SREx-20 BR HT Power Connection Kit ELSR-HA, -NA with nickel plated cable gland, M20 (hazardous location) 09CA008 ELVB-SREx-20 BR HT Power Connection Kit ELSR-WA, with nickel plated cable gland, M20 (hazardous location) 09CA028 ELVB-SREx-1/2" BR HT Power Connection Kit ELSR-WA with nickel plated cable gland, 1/2" NPT (hazardous location) 09CA029 ELVB-SRAH-3/4" ST Power Connection Kit ELSR-HA with steel/zinc cable gland/fitting, 3/4" NPT (non-hazardous location) 09CA011 ELVB-SRAN-3/4" ST Power Connection Kit ELSR-NA with steel/zinc cable gland/fitting, 3/4" NPT (non-hazardous location) 09CA012 ELVB-SRAM-3/4" ST Power Connection Kit ELSR-MA, -MA-BF with steel/zinc cable gland/fitting, 3/4" NPT (non-hazardous location) 09CA013 ELVB-SRAW-3/4" ST Power Connection Kit ELSR-WA with steel/zinc cable gland/fitting, 3/4" NPT (non-hazardous location) 09CA019 ELVB-SRAH Power Connection kit ELSR-HA without gland 09CA014 ELVB-SRAN Power Connection kit ELSR-NA without gland 09CA015 ELVB-SRAM Power Connection kit ELSR-MA without gland 09CA052 ELVB-SRAW Power Connection kit ELSR-WA without gland 09CA053 Possible combinations of heating cable and kit End Termination Kits ELSR-HA (-WS) ELSR-NA (-WS) ELSR-HA, Ex Zone 1, Div 2, Class I, II, III, Div 2 ELSR-NA, Ex Zone 1, Div 2, Class I, II, III, Div 2 ELSR-MA ELSR-MA-BF ELSR-WA (-WS) ELSR-WA (-WS), Ex Zone 1, Div 2, Class I, II, III, Div 2 EL-ECH-ex End Termination Kit for ELSR-HA 09CA021 EL-ECN-ex End Termination Kit for ELSR-NA, -WA 09CA022 EL-ECW End Termination Kit for ELSR-WA 09CA043 EL-ECM End Termination Kit for ELSR-MA 09CA041 EL-ECMF End Termination Kit for ELSR-MA-BF 09CA042 min. installation -49 F (-45 C ) coverage: braiding 80 %, aluminum foil 0 % min. installation -25 F (-13 C ) 18 Self-Regulating Heating Cable

19 Self-Regulating Heating Cables Accessories Further Accessories Designation Description Item No. Possible combinations of heating cable and kit Heater Entry Kit ELSR-HA (-WS) ELSR-NA (-WS) ELSR-HA, Ex Zone 1, Div 2, Class I, II, III, Div 2 ELSR-NA, Ex Zone 1, Div 2, Class I, II, III, Div 2 ELSR-MA ELSR-MA-BF ELSR-WA (-WS) ELSR-WA, Ex Zone 1, Div 2, Class I, II, III, Div 2 EL-HAZELECT Heater entry kit for Div1 rated junction box, 3/4" NPT, for ELSR-NA and -HA, Division 1 rated hazardous location 09CA051 Mechanical Fasteners ELB-1. Mechanical fastener, plastic strap, L= 2 x 2.5 mm ELB-1.20 Mechanical fastener, plastic strap, L = 200 x 3. mm ELB-1.3 Mechanical fastener, plastic strap, L= 30 x 4.8 mm ELB-18 Mounting/fixing plate for gutter installation Self-Adhesive Tape and Foil ELB-03 Self-adhesive glass fibre tape, max T = 194 F (90 C), 50 m ELB-0D Self-adhesive aluminum foil, max T = 284 F (140 C), 0 m ELB-0E Self-adhesive aluminum foil, max T = 302 F (150 C), 50 m ELB-02A Self-adhesive glass fibre tape, max T 35 F (180 C), 33 m Warning labels / signs EL-WS01 E Warning label/sign, English "Electric Heat Tracing" (other languages upon request) Self-Regulating Heating Cable 19

20 Eltherm Canada Inc. Product Warranty 1. Warranty Period The warranty period applicable to equipment manufactured by Eltherm ( Warranty Period ) shall end 12 months from date of installation or 18 months from date of shipment of the equipment to purchaser, whichever occurs first, unless otherwise negotiated in writing with Eltherm. 2. Warranty During the Warranty Period, Eltherm warrants that equipment subjected to normal use and service will be free from defects in materials and workmanship and will substantially conform to any quality or performance specifications that have been acknowledged and agreed to in writing by Eltherm. 3. Remedy for Breach of Warranty 3.1 In the event of any breach of the warranty set out in Section 2 above, Eltherm shall, at its sole option and subject to the terms of this warranty, either repair or replace the defective equipment. In addition, instead of repairing or replacing the equipment, Eltherm may, at its option, take back the defective equipment and refund in full settlement the purchase price paid by the purchaser for the equipment. 3.2 Eltherm s obligation under this warranty does not include the cost of furnishing any labour in connection with the removal of defective equipment or the installation of repaired or replaced equipment or parts thereof; nor does it include the responsibility for or cost of transportation. 4. Warranty Conditions and Exclusions 4.1 The warranty set out in Section 2 above does not cover any defect, damage or condition resulting from, caused by, relating to or arising out of, directly or indirectly: (i) failure to assemble, install or use the equipment other than in strict conformity with instructions provided by Eltherm ; (ii) dismantling, re-assembly, modification, alteration, repair or testing of the equipment by anyone other than Eltherm or its authorized service providers; (iii) the use of parts, components or accessories that have not been provided by Eltherm ; (iv) improper maintenance of or failure to maintain the equipment in accordance with Eltherm s instructions; (v) defect, breakdown or malfunction of other devices, parts, components, materials or services used in connection with the equipment that are that are manufactured by anyone other than Eltherm ; (vi) damage or destruction of the equipment by external influences, including, without limitation, accident, vandalism, fire, flooding, explosions, power outages, electromagnetic disturbances, lightning, extreme weather conditions, and force of elements; (vii) incorrect storage or inappropriate transport of the equipment by anyone other than Eltherm or its authorized sellers before installation; (viii) normal wear and tear. 4.2 Eltherm shall not be liable under this warranty for statements, claims, warranties or representations made relating to the equipment by anyone other than Eltherm as set out in its written product descriptions and specifications. 4.3 Eltherm makes no warranty as to and shall not be liable for the truth or accuracy of product descriptions or specifications issued by suppliers of materials, parts or components used in the manufacture of the equipment. 4.4 Authorized repairs to equipment during the Warranty Period will not interrupt or prolong the Warranty Period. 5. Claims Process 5.1 To receive service under this warranty, purchaser must notify the authorized seller of the product at its place of business or Eltherm directly. 5.2 Eltherm s obligation under this warranty is limited to the repair or replacement of the defective product, at its option, f.o.b. point of shipment, provided that prompt notice of any defect is given by purchaser within the Warranty Period and that upon purchaser s return of the defective part to Eltherm or, if designated by Eltherm, to its authorized representative, properly packed and with transportation charges prepaid by purchaser, an inspection thereof reveals to Eltherm s satisfaction that purchaser s claim is valid under the terms of this warranty. Purchaser shall assume all responsibility and expense for dismantling, removal, re-installation and freight in connection with the foregoing.. Limitations To the extent permitted by applicable law, this warranty is expressly intended to exclude all other express or implied warranties, including without limitation any warranty of merchantability or fitness for a particular purpose. The provisions of this warranty constitute purchaser s sole remedy with respect to defective equipment. Except as otherwise expressly provided in this warranty, eltherm makes no representation, warranty or condition of any kind, whether by statute, usage, custom of trade or otherwise with respect to any equipment, and disclaims any and all implied warranties and conditions relating thereto, including but limited to any warranty or condition of merchantability or fitness for a particular purpose. Eltherm and its affiliates, shareholders, officers, directors, employees and authorized representatives shall not be liable, and purchaser waives all claims against any and all of them, for any indirect, incidental, special, punitive or consequential damages, lost profits or commercial losses whatsoever. Eltherm and its affiliates, shareholders, officers, directors, employees and authorized representatives will not under any circumstances be liable, and purchaser waives all claims against any and all of them, for any loss, damage or injury to person, including death, or property. In no event will eltherm have any liability to any person relating to the equipment that exceeds the purchase price of the specific equipment as to which a claim is made. 7. General 7.1 If any provision of this warranty is held unenforceable or illegal by a court or other body of competent jurisdiction, such provisions shall be modified to the minimum extent required such that the rest of this warranty will continue in full force and effect. 7.2 The rights and responsibilities granted under this warranty shall be governed and construed in accordance with the laws of the Province of Ontario, without regard to its conflict of law principles. The courts of competent jurisdiction of the Province of Ontario shall have exclusive jurisdiction with respect to any action or proceeding relating to this warranty. Available from: #1, Goddard Ave. NE Calgary, Alberta T2K 5X3 Canada Tel.: Fax: Customer Toll Free (U.S. & Canada): Heat (4328) PRINTED IN CANADA Copyright 201 HH Cat No. ELSR _Brochure_ELSR_USA_20s Hazloc Heaters is a trademark of Hazloc Heaters Inc. The information contained in this brochure has been carefully checked and verified for accuracy. Specifications subject to change without notice.

Self-Regulating Parallel Heating Cables. innovations in heat tracing

Self-Regulating Parallel Heating Cables. innovations in heat tracing Self-Regulating Parallel Heating Cables innovations in heat tracing ELSR Application Options The application options for the ELSR heating cables range from freeze protection to maintenance of pipes and

More information

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA eltherm Canada Inc. 1440 Graham s Lane, Unit 5 Burlington Ontario L7S 1W3 Canada Phone: +1 (289) 812-6631 Fax: +1 (844) 325-6750 E-Mail:

More information

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

PVI 60KW, PVI 82KW, PVI 95KW

PVI 60KW, PVI 82KW, PVI 95KW PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy

More information

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual UniTorq UTQ 1.5 6.4 Quarter-Turn Actuator Installation and Operation Manual Thank you for purchasing our UTQ 1.5-6.0 Electric Actuators Before installation or operation of the actuator carefully review

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60 60 PSI Boost Gauge For Product Numbers: MT-DV01_60, MT-WDV01_60 Red: 12v Constant (un-switched) Source (+) Orange: 12v Dimmer (switched) Source (+) (optional) White: 12v Ignition (switched) Source (+)

More information

Installation Power Management Unit Battery Cables and Battery Harness

Installation Power Management Unit Battery Cables and Battery Harness Installation Power Management Unit Battery Cables and Battery Harness Important Safety Messages SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation

More information

Installation Manual & Warranty

Installation Manual & Warranty Installation Manual & Warranty MuD Public Workplace Table of Contents What's Included... 2 Before Installation... 3 Safety Check... 4 Grounding Instructions... 4 Recommended Tools... 4 Installing the eluminocity

More information

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Cabling for power, control, and video must be run to the installation site before the mount is installed. User Installation User Guide Guide & Operation Manual V940D V-20B-A-2 V940D Mounting Kits Mounting Pole Mounting Kits Adapter X532-11-00 Vicon Industries Inc. does not warrant that the functions contained

More information

PowerFLEX Module Limited Warranty Program

PowerFLEX Module Limited Warranty Program PowerFLEX Module Limited Warranty Program Global Solar provides a limited warranty applicable to the Global Solar PowerFLEX TM Modules listed below: PowerFLEX TM 6-Meter - - FG-1 BT(M or N)-(275 or 300)

More information

END USER TERMS OF USE

END USER TERMS OF USE END USER TERMS OF USE The following is the End Users Terms of Use as it currently appears in the Mobileye User Manual and Warranty information. This is here for your review and information; it is subject

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

1. GENERAL INFORMATION

1. GENERAL INFORMATION 1. GENERAL INFORMATION Description BRITECH PT Self-Regulation Heating Cables For Hazardous Locations, High Temperatures and Chemical Resistance (Class I, Div. 2) Consult factory for Class I, II & III locations,

More information

Users Guide for Ac-sync

Users Guide for Ac-sync Problem solved. Users Guide for Ac-sync Thank you for choosing Anywhere Cart! The AC-SYNC is designed to sync, charge and store 1-36 ipads or tablets. Adjustable device divider bays allow fitment of any

More information

BYD B-Box Limited Warranty Letter

BYD B-Box Limited Warranty Letter BYD B-Box Limited Warranty Letter Applicable Country: Australia Effective date: 01 st, Jul., 2017 BYD B-Box System Applicable product types: B-Box H 6.4 / B-Box H 7.7 / B-Box H 9.0 / B-Box H 10.2 / B-Box

More information

DRAIN WATER TEMPERING KIT

DRAIN WATER TEMPERING KIT INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR FOR USE WITH SH(X) GAS FIRED HUMIDIFIER OUTDOOR MODELS CANADIAN HEAD OFFICE AND FACTORY 1401 HASTINGS CRES. SE CALGARY, ALBERTA T2G 4C8 Ph: (403) 287

More information

INSTALLATION INSTRUCTION & OWNER S MANUAL

INSTALLATION INSTRUCTION & OWNER S MANUAL CS-2500 & CS-2500P Water Filtration System INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 1.2 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful

More information

BMRX Series ROTARY LEVEL CONTROL

BMRX Series ROTARY LEVEL CONTROL BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...

More information

HR-20P Pneumatically Controlled Pressure Regulator

HR-20P Pneumatically Controlled Pressure Regulator HR-20P Pneumatically Controlled Pressure Regulator Instruction and Service Manual Hydroplex Corporation 230 West Gloria Switch Rd. Lafayette, LA 70507 337-233-0626 www.hydroplexpumps.com I. General Instructions

More information

Heating Cables Heating Tapes. innovations in heat tracing

Heating Cables Heating Tapes. innovations in heat tracing Heating Cables Heating Tapes innovations in heat tracing Table of Contents Introduction 3 Type ELP/SI Constant Wattage Heating Cable up to 200 C 4-5 Type ELP/SI-F Constant Wattage Heating Cable up to 200

More information

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance Power Controller Assembly, Operation, & Maintenance Congratulations on your purchase, and thank you for selecting the Power Controller from Blichmann Engineering. We are confident that it will provide

More information

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty EZ-R7 T-Plug Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors Installation Instructions and Product Warranty Professional Installation Required Thank you for purchasing

More information

User s Manual for Tennessee Chill Box System P/N CB8000

User s Manual for Tennessee Chill Box System P/N CB8000 User s Manual for Tennessee Chill Box System P/N CB8000 Read and understand all instructions before using this product. Open carton carefully and inspect product for damage caused by carrier. If any damage

More information

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual Installation Instructions Tech Support: 856.768.8300 TechSupport@GlowShiftGauges.com DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual (1) Gauge (2) Controllers

More information

FCB-450, LCB-600, MCB-800

FCB-450, LCB-600, MCB-800 AIR CHAMP PRODUCTS User Manual FCB-450, LCB-600, MCB-800 Clutch-Brakes (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are

More information

TRACKS BUILT TO LAST. AGRICULTURAL MADE FOR AGRICULTURE. PROVEN TO PERFORM. FOR HIGH-HORSEPOWER TRACTORS

TRACKS BUILT TO LAST. AGRICULTURAL MADE FOR AGRICULTURE. PROVEN TO PERFORM. FOR HIGH-HORSEPOWER TRACTORS AGRICULTURAL TRACKS MADE FOR AGRICULTURE. PROVEN TO PERFORM. BUILT TO LAST. When it comes to tracks for agriculture, we understand the need for strength and durability. Our commitment to quality is steadfast.

More information

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT LOAD CAPACITY: 500 LBS [227 kg] MANDATORY: LEAVE THIS MANUAL WITH LIFT OWNER WARNING 1. READ AND FOLLOW ALL INSTRUCTIONS. LIFT SAFETY

More information

Kompensator External Low Voltage Heating Cable System

Kompensator External Low Voltage Heating Cable System External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions Level Alert Model 2000 Multi-Switch Liquid Level Sensor Assembly and Installation Instructions Kit Form Each unit is provided in kit form with step-by-step instructions, making it extremely easy to custom

More information

Rig Master Power by Mobile Thermo Systems Inc.

Rig Master Power by Mobile Thermo Systems Inc. RigMaster Power Dealer Warranty Policy The Limited Warranty This limited warranty applies to the RigMaster Auxiliary Power Unit (RigMaster APU) which consists of the following components: 1. The generator

More information

Service Guide JATCO Environmental Protection Tank Model J-7000

Service Guide JATCO Environmental Protection Tank Model J-7000 Service Guide JATCO Environmental Protection Tank Model J-7000 Listed below are a series of steps to follow if the JATCO tank fails to dump properly. #1. Be sure there is an adequate supply of gas pressure

More information

Straight-Bore Clutch LSCC-32, 44, 54

Straight-Bore Clutch LSCC-32, 44, 54 Straight-Bore Clutch LSCC-32, 44, 54 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

CBC-160-1N and CBC-160-2N Clutch/Brake Controls P-239-36 819-04 CBC-160-1N and Clutch/Brake Controls Installation Instructions An Altra Industrial Motion Company Contents Introduction...2 Specifications........................... 2 Installation...3

More information

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS User Manual Revision June 2008 Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply LIMITED WARRANTY FOR DOTWORKZ SYSTEMS

More information

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev

More information

10 Year Limited Warranty

10 Year Limited Warranty Power. On Your Terms. 10 Year Limited Warranty PHI 2.7 TM PHI 3.5 TM 60A SIMPLIPHI POWER, INC. REV020618 10 Year Limited Warranty: PHI 2.7 TM PHI 3.5 TM 60A 24V 48V Limited Pro-Rated Warranty Coverage

More information

Utility Controller Hand Air Operated

Utility Controller Hand Air Operated Utility Controller Hand Air Operated P-1395 819-0288 Installation Instructions Introduction The Warner Electric air/manual Utility Controller combines manual and automatic (air) actuation for the operation

More information

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016 Document N0. 1800-09 Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000

More information

TRUCK PRODUCT LINE A DIVISION OF DAKOTA FLUID POWER, INC.

TRUCK PRODUCT LINE A DIVISION OF DAKOTA FLUID POWER, INC. TRUCK PRODUCT LINE 2210 Main Ave W, West Fargo, ND 58078 877.410.7072 www.epgdivision.com A DIVISION OF DAKOTA FLUID POWER, INC. ABOUT US About: Engineered Products Group (EPG), a division of Dakota Fluid

More information

StormPro BCV400 Sewage Ejector Pump

StormPro BCV400 Sewage Ejector Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

LEV/Wn Building A Connected World

LEV/Wn Building A Connected World LEV/Wn Building A Connected World PK-93370-10-00-2B Installing and Testing a GFCI Please read this leaflet completely before getting started. A CAUTION To prevent severe shock or electrocution always turn

More information

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR) TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for

More information

Electromagnetic Particle Brakes Model: PRB-H

Electromagnetic Particle Brakes Model: PRB-H P-223-3 819-0370 Electromagnetic Particle Brakes Model: PRB-H Installation Instructions Table of Contents Introduction............................2 Installation Instructions....................3 Start

More information

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com

More information

G3PE-Single-phase. Solid State Relays for Heaters

G3PE-Single-phase. Solid State Relays for Heaters Solid State Relays for Heaters Single-phase CSM_Single-phase_DS_E Compact, Slim-profile SSRs with Heat Sinks. s with No Zero Cross for a Wide Range of Applications. RoHS compliant. s also available with

More information

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

The Ultimate Smart Grid Solution INSTRUCTION MANUAL ECOWISE EW30/1 The Ultimate Smart Grid Solution INSTRUCTION MANUAL Welcome! Congratulations on selecting the ECOWISE unit to manage your energy supply needs. ECOWISE units reduce the amount of electric

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (USED FOR POWERING ENVIRONMENTAL ENCLOSURE MODELS MODELS 854030, 8535 AND 8537) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION C JUNE 2017

More information

Power. On Your Terms.

Power. On Your Terms. Power. On Your Terms. 10 YEAR LIMITED WARRANTY PHI 1310 TM 1 SIMPLIPHI POWER, INC. REV102016 10 YEAR LIMITED WARRANTY: PHI 1310 TM LIMITED PRO-RATED WARRANTY COVERAGE The SimpliPhi Power PHI 1310 as supplied

More information

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II Document No.: LMSII_V100_OM Page 1 of 8 LMS II Document No.: LMSII_V100_OM Page 2 of 8 1. Operation: When the wet well level rises above the on level set point, the lead pump will start after an adjustable

More information

Female Plug. connecting to Fuel Quantity

Female Plug. connecting to Fuel Quantity **Ag Diesel Solutions recommends replacing the Transorb/Suppressor Diode before the installation of this module*** Red wire = 12V Constant power. Male Plug connecting to Fuel Quantity Valve Black wire

More information

80PK-2A Type K Immersion Probe

80PK-2A Type K Immersion Probe 80PK-2A Type K Immersion Probe Instruction Sheet WARNING TO AVOID ELECTRICAL SHOCK, DO NOT USE THIS PROBE WHEN VOLTAGES EXCEEDING 24V AC RMS OR 60V DC ARE PRESENT. THE PROBE TIP IS ELECTRICALLY CONNECTED

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L Thank you for purchasing DigiGauge by ZAETECH Disclaimer DigiGauge is for show and off road use only. By using this

More information

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414 AIR CHAMP PRODUCTS User Manual Sheave & Pilot Mount Clutch-Brake Model BCB-275 i In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual

More information

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions 1999-2006 Mercedes MBE 906/926 6.4L & 7.2L Engine Module Part # 15000 Installation Instructions 15000_revC 1999-2006 Mercedes 6.4L & 7.2L Engine Module +12 volts red wire. Ground black wire Injector Terminals

More information

DAP-625S and DAP-875S

DAP-625S and DAP-875S AIR CHAMP PRODUCTS DAP-625S and DAP-875S (i) FORM NO. L-20078-B-0501 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs

Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs (P/N 10067285) Instruction Manual " WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR

More information

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide 7.3L POWERSTROKE BANJO BOLT KIT Fits 94-03 7.3L Powerstroke Diesel Installation Guide INSPECT CONTENTS OF THIS KIT THOROUGHLY BEFORE STARTING THE INSTALLATION PROCESS! IF YOU FIND A PROBLEM WITH YOUR PACKAGE:

More information

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1 STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com

More information

RANGE HOODS USER INSTRUCTIONS

RANGE HOODS USER INSTRUCTIONS RANGE HOODS USER INSTRUCTIONS Model: Advanta Pro III 30 & 36 IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance. Keep these instructions

More information

Motorized Stainless 2-Way Valves

Motorized Stainless 2-Way Valves Installation and Operation Manual Motorized Stainless 2-Way Valves Safety Valve ETV Applications WARNING This Heat-Timer valve is strictly an operating valve; it should never be used as a primary limit

More information

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com 21700 Module Installation Guide 2017 GM 6.6L Duramax *L5P* Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable Switch Female Fuel Pressure Sensor Connector Male Fuel Pressure Sensor Connector

More information

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform

More information

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO MEX (55) 5 6 QRO (44) 95 7 60 MTY () 54 0 BC Brake Caliper (i) FORM NO. L-0066-B-040 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this

More information

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings. Instruction-Parts ASM Maxi Poles 312483B For the application of architectural paints and coatings. 3400 Series 4050 psi (27.92 MPa, 280 bar) Maximum Working Pressure Important Safety Instructions Read

More information

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS 480 MODELS VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS REPAIR PARTS INDEX NOTE! Read and understand the pump and driver instructions before attempting to install, disassemble or repair the pump. Part

More information

Infrared Thermocouple Probe

Infrared Thermocouple Probe 80PK-IR Infrared Thermocouple Probe Instruction Sheet 80PK-IR INFRARED TEMPERATURE PROBE 0 to 500 F / -18 to 260 C INTRODUCTION The Fluke 80PK-IR Infrared Thermocouple Probe (the probe) is a noncontact

More information

AD-7 THERMAL INDICATING AMMETER

AD-7 THERMAL INDICATING AMMETER AD-7 THERMAL INDICATING AMMETER a nd ACCESSORIES Operating & Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E W A U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. P H O N E 8 4 7.

More information

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

RipTide. Brewing Pump. Assembly, Operation, & Maintenance RipTide Brewing Pump Assembly, Operation, & Maintenance Congratulations on your purchase, and thank you for selecting the RipTide brewing pump from Blichmann Engineering. We are confident that it will

More information

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704 Elgin Hydraulic Clutch-Brake ECB-20, Product Number 96225 FORM NO. L-20283-F-070 1 FORM NO. L-20283-F-070 In accordance with Nexen s established policy of constant product improvement, the specifications

More information

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442) Through-Shaft Clutch-Brake LSCB-HT, LSCB-HT, LSCB-, LSCB-HT, LSCB-5HT In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

ERD Electrically Released Brakes

ERD Electrically Released Brakes ERD Electrically Released Brakes P-229 819-0453 Installation Instructions Warner Electric s ERD series spring set, electrically released brakes are designed to hold a load when the power to the brake is

More information

3V SERIES SOLENOID VALVE

3V SERIES SOLENOID VALVE 3V110-410 SERIES SOLENOID VALVE Valve Model 3V110-1/8 3V210-1/4 3V310-3/8 3V410-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Air Pilot, Spool Design, Response Time

More information

Submersible Pump Model FA10.78Z with 4 Pole, 1740 RPM Motor and Two Vane Impeller

Submersible Pump Model FA10.78Z with 4 Pole, 1740 RPM Motor and Two Vane Impeller Submersible Pump Model FA10.78Z with 4 Pole, 1740 RPM Motor and Two Vane Impeller Project Name: Project Manager: Chris Harnevious, Order Management Prepared By: Ray Herndon, Order Management FA 10.78Z,

More information

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES Instruction D11023 October 2016 Instructions These instructions provide information about KGN-RSB Knife Gate Valves. They are

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

5 BBL Hybrid Brewhouse

5 BBL Hybrid Brewhouse 5 BBL Hybrid Brewhouse Installation Congratulations on your purchase, and thank you for selecting the 5 BBL Hybrid Brewhouse from Blichmann Engineering. We are confident that it will provide you years

More information

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual Switch-Tek Horizontal, Vertical & Float-Point Float Switches AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA

More information

15100 Module Installation Guide Mercedes EPA07 w/dpf

15100 Module Installation Guide Mercedes EPA07 w/dpf 15100 Module Installation Guide 2007-2009 Mercedes EPA07 w/dpf 7.2L Engines Up to 30% HP Gain 10-20% Fuel Savings AgDieselSolutions.com 2007-2009 Mercedes 7.2L Engine Module +12 volts red wire. Ground

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 14, 2019

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 14, 2019 IMPORT PRICE LIST PIPE FITTING EFFECTIVE JANUARY 14, 2019 version: IMP-ACC-UPL.19.01 EFFECTIVE: JANUARY 14, 2019 (SUPERSEDES ALL PREVIOUS PRICING) CORONA CALL CENTER (U.S.) Toll Free: (877) 701-7827 Fax:

More information

SUNTURA SOLAR TRACKER

SUNTURA SOLAR TRACKER WindyNation SUNTURA SOLAR TRACKER SOT-TRKS-NF User s Manual Page 1 of 10 WindyNation 08/09/2012 Table of Contents 1 Introduction... 3 1.1 Limited Warranty... 3 1.2 Restrictions... 3 1.3 Warranty Claims

More information

30100 Module Installation Guide L

30100 Module Installation Guide L 30100 Module Installation Guide 1997-2006 12.0L Mack Engines Up to 30% HP Gain 10-20% Fuel Savings AgDieselSolutions.com 1997-2006 Mack 12.0L Engine Module +12 volts red wire. Ground black wire Injector

More information

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

HATCHGRIP Installation Instructions/Operation and Maintenance Manual HATCHGRIP Installation Instructions/Operation and Maintenance Manual Models: HTG-PCG Contact Information Table of Contents: Safety Precautions... 2 Product Information... 2 Operation... 3 Installation

More information

i400s Calibration Information Introduction

i400s Calibration Information Introduction i400s AC Current Clamp Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration procedures unless you are qualified to do so. The information provided

More information

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This

More information

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

The Ultimate Smart Grid Solution INSTRUCTION MANUAL ECOWISE EW20/1 EW30/1 The Ultimate Smart Grid Solution INSTRUCTION MANUAL Welcome! Congratulations on selecting the ECOWISE unit to manage your energy supply needs. ECOWISE units reduce the amount of electric

More information

CU6703 Module Installation Guide

CU6703 Module Installation Guide Up to 30% More Horsepower 10-20% Fuel Savings Cummins 6.7L Tier III Engines CU6703 Module Installation Guide AgDieselSolutions.com MAP sensor male and female connectors. Power and Ground wires. Module

More information

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Open Display Merchandiser Installation and Operation Manual Please read this manual completely

More information

20250 Module Installation Guide

20250 Module Installation Guide 20250 Module Installation Guide 2013.5-2017 RAM 6.7L Cummins Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable switch connector Power +12 volts (Red wire) & Ground (Black wire) Injector

More information

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title Product/ Title Guardian Super Flex Shaft Coupling Product/ Title GUA-MRK-DOC-027 P-XXXX-GC Service&&Installation Installation Instructions Instructions Service An Altra Industrial Motion Company TABLE

More information

Electric Pilot System Assembly, Operation, & Maintenance

Electric Pilot System Assembly, Operation, & Maintenance Electric Pilot System Assembly, Operation, & Maintenance Congratulations on your purchase, and thank you for selecting the Electric Pilot System from Blichmann Engineering Pro Series. We are confident

More information

Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved

Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved For more information about this kit, visit http://www.grapesolar.com/manuals.html Series vs. Parallel Connections

More information

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number EQUIPMENT Instructions Loctite Pneumatic 300 ml Cartridge Dispenser Part Number 1294304 1. Unpacking and Inspection Carefully unpack the Loctite Pneumatic 300 ml Cartridge Dispenser and examine the items

More information

Series 2100 Operating Instructions

Series 2100 Operating Instructions Series 2100 Operating Instructions Installation Instructions Visit the link below or scan the QR code to watch a detailed installation video: http://triteqlock.com/fresh After the lock, temperature probe,

More information