Heating Cables. For Industry Tracing

Size: px
Start display at page:

Download "Heating Cables. For Industry Tracing"

Transcription

1 Heating Cables For Industry Tracing

2 FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length (up to 125 meters) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over itself (overlapped). Suitable for use in non-hazardous, hazardous and corrosive environments. FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive. Application FFHT-X is an industrial grade, ATEX approved self-regulating parallel heating cable (heating tape) manufactured in accordance to BS6351 Grade 22, that can be used for applications ranging from process heating or maintenance of temperature up to 120. It can be used in hazardous and non-hazardous locations, including areas where corrosives may be present. Option FFHT-X C Tinned copper or stainless steel braid provide additional mechanical protection and a positive groundpath. FFHT-X CG High Temperature Fluoropolymer overjacket are used for exposure to organic or corrosive solutions or vapors may be present. Tinned copper buswires Technical data Service voltage Maximum maintain temperature (power on) Maximum exposure temperature (power off) 110V/ +120 (250 ) +200 (390 ) Self-regulating semi-conductive core Inner insulation Tinned copper braid Minimum installation temperature -40 (-40 ) Protective braid resistance Bus wire gauge Approvals < 18.2Ω/km EPT 16 ATEX 2551 X Optional outer jacket

3 FATI-FFHT-X 2/2 FFHT-X Dimension and weight Type Dimension Min.bending radius Weight (kg/100m) FFHT-X C mm 26mm 9.7 FFHT-X CT mm 32mm 9.5 Product ordering information Power output curves Nominal power output at when FFHT-X is installed on insulated pipes. FFHT-X -C For example: FFHT-X-15.2-CG 40 Outer jacket G=Fluorpolymer Tinned Copper Braid Supply Voltage 1= VAC; 2= VAC Power in W/m at +5 C 15=15W/m; 30=30W/m W/m B A 15FFHT-X B 30FFHT-X Type of cable 10 A C Pipe temperature C Maximum length (m) vs. circuit breaker size Circuit Breaker Size 16A 20A 25A 32A Start-up Temperature 40 C 20 C 10 C 10 C 40 C 20 C 10 C 10 C 40 C 20 C 10 C 10 C 40 C 20 C 10 C 10 C 120V FFHT-X V FFHT-X F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

4 FATI-FFBT-X 1/2 FFBT -X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length (up to 125 meters) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over itself (overlapped). Suitable for use in non-hazardous, hazardous and corrosive environments. FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive. Application FFTB-X is an industrial grade, ATEX approved self-regulating parallel heating cable (heating tape) manufactured in accordance to BS6351 Grade 22, that can be used for applications ranging from process heating or maintenance of temperature up to 65. It can be used in hazardous and non-hazardous locations, including areas where corrosives may be present. Option FFBT-X C Tinned copper braid provide additional mechanical protection and a positive groundpath. FFBT-X CG High Temperature Fluoropolymer overjacket are used for installationin hazardous location or where corrosive solutions or vapors may be present. Technical data Service voltage Maximum maintain or continuous exposure temperature (power on) Maximum intermittent exposure temperature 1000 hours (power on or off) 110V/ +65 (149 ) +75 (167 ) Tinned copper buswires Self-regulating semi-conductive core Inner insulation Tinned copper braid Minimum installation temperature -40 (-40 ) Protective braid resistance Bus wire gauge Approvals < 18.2Ω/km EPT 16 ATEX 2551 X Optional outer jacket

5 FATI-FFBT-X 2/2 FFBT-X Dimension and weight Type Dimension Min.bending radius Weight (kg/100m) FFBT-X C mm 26mm 9.7 FFBT-X CT mm 32mm 9.5 Product ordering information Power output curves Nominal power output at when FFBT-X is installed on insulated pipes. FFBT-X -C For example: FFBT-X-15.2-CG 30 Outer jacket G=Fluoropolymer A 15FFBT-X B 26FFBT-X Tinned Copper Braid Supply Voltage 1= VAC; 2= VAC Power in W/m at +5 C 15=15W/m; 26=26W/m Type of cable W/m W/m 20 B 10 A Pipe temperature C Maximum length (m) vs. circuit breaker size Circuit Breaker Size 16A 20A 25A 32A Start-up Temperature 40 C 20 C 10 C 10 C 40 C 20 C 10 C 10 C 40 C 20 C 10 C 10 C 40 C 20 C 10 C 10 C 120V FFBT-X V FFBT-X F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

6 FATI-FCTU 1/2 FCTU Features The FCTU series of self-regulating heating cables are designed to supply a specified amount of heat at any point along their length in direct response to local temperature variations. These cables can maintain temperatures up to 375 F (190 C) and will withstand 190 psig saturated steam purging and intermittent temperature excursions to 475 F (250 C) with power applied. FCTU cables can be cut to length and terminated in the field, and will not overheat or burnout when overlapped. Application The industrial grade FCTU cables provide freeze protection and process temperature maintenance for fluid transport and storage systems requiring very high levels of heat output or exposure to elevated temperatures. The bus wires, jackets and metallic braids can be configured for both ordinary (non-classified) locations and hazardous (classified), including areas where exposure to corrosive or organic materials is possible. Technical data Output wattage (other wattages also available) Supply voltages Continuous maintenance temperature Intermittent exposure temperature T Rating Temperature Class Braid resistance Size Min. bending radius 15, 30, 45, 0 C or 208V-277Vac 375 F (190 C) max 475 F (250 C) max T Ohm/ 11.0mmx5.2mm 33mm Nickel coated copper buswires Self-regulating Fluoropolymer conductive core Inner insulation Nickel copper overshield Optional outer jacket

7 FATI-FCTU 2/2 FCTU Power Adjustment Factor Part No. 208 Volts 277 Volts 15FCTU2-CT FCTU2-CT Power output curves Nominal power output at when FCTU is installed on insulated pipes 70 45FCTU2-CT FCTU2-CT D A 15FCTU B 30FCTU C 45FCTU D 60FCTU Product ordering information FCTU - C For example: 15FCTU2-CTor example: 15HTP2-CT Outer jacket T=Fluorpolymer Nickel Copper Supply Voltage 1= VAC; 2= VAC Type of cable Power in W/ at 10 C 15=15W/; 30=30W/ 45=45W/; 60=60W/ W/ C B A C Pipe temperature C Maximum length () vs. circuit breaker size Minimum Start-up temperature CB size Amps 15FCTU 30FCTU 45FCTU 60FCTU 120V 240V 120 V 240V 120 V 240V 120 V 240V (10 ) (-20 ) (-45 ) F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

8 FATI-FCTS 1/2 FCTS Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over itself (overlapped). Suitable for use in non-hazardous, hazardous and corrosive environments. FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive. Application FCTS is an industrial grade, self-regulating parallel heating cable (heating tape) manufactured in accordance to BS6351 Grade 22, that can be used for applications ranging from process heating or maintenance of temperature up to 150. It can be used in hazardous and non-hazardous locations, including areas where corrosives may be present. Option FCTS C FCTS CT High Tinned copper braid provide additional mechanical protection and a positive ground path. Temperature Fluoropolymer overjacket are used for exposure to organic or corrosive solutions or vapours may be present. Technical data Service voltage V, V Maximum maintain or continuous exposure temperature (power on) Maximum intermittent exposure temperature 1000 hours (power on or off) ( ) +200 (392 ) Tinned copper buswires Self-regulating semi-conductive core Inner insulation Tinned copper braid Minimum installation temperature -30 (-22 ) Protective braid resistance Bus wire gauge Approvals < 18.2Ω/km CE Optional outer jacket

9 FATI-FCTS 2/2 FCTS Dimension and weight Type Dimension Min.bending radius Weight (kg/100) FCTS C mm 21mm 11.2 FCTS CR mm 36mm 11.0 Product ordering information Power output curves Nominal power output at 240V when FCTS installed on insulated metal pipes. FCTS - C For example: 15FCTS2-CT Outer jacket T=Fluorpolymer Tinned Copper Braid Supply Voltage 1= VAC; 2= VAC Type of cable Power in W/ at 10 C 5=18W/; 10=35W/ 15=50W/; 20=65W/ W/ D C B A 5FCTS B 10FCTS C 15FCTS D 20FCTS A C Pipe temperature C Maximum length () vs. circuit breaker size Minimum Start-up temperature -20 (-4 ) 10 (50 ) CB size Amps 5FCTS 10FCTS 15FCTS FCTS F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

10 FATI-FCTR 1/2 FCTR Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over Itself (overlapped). Suitable for use in non-hazardous, hazardous and corrosive environments. FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals corrosive Application FCTR is Industrial Rate approved self-regulating parallel heating cable (heating tape), designed for a variety of industrial applications and enviroments, including hazardous and non-hazardous. It can be used for plastic or mental pipe freeze protection and flow maintenance of pipes, tanks, valves. Option FCTR C FCTR CR Flame FCTR CT High Tinned copper braid provide additional mechanical protection and a positive ground path. retardant thermoplastic over jacket protect against certain inorganic chemical solutions, it also protect against abrasion and impact damage. Temperature Fluoropolymer. Over jacket are used for exposure to organic or corrosive solutions or vapours. Tinned copper buswires Technical data Service voltage V, V Maximum maintain or continuous exposure temperature (power on) Maximum intermittent exposure temperature 1000 hours (power on or off) +65 (149 ) +85 (185 ) Minimum installation temperature -40 (-40 ) Self-regulating semi-conductive core Inner insulation Tinned copper braid Optional outer jacket Protective braid resistance Bus wire gauge < 18.2Ω/km

11 FATI-FCTR 2/2 FCTR Dimension and weight Type Dimension Min.bending radius FCTR C mm 26mm 10.5 Weight (kg/100) Power output curves Nominal power output at 240V when FCTR installed on insulated metal pipes. 60 FCTR CR mm 36mm 13.8 FCTR CT mm 32mm 13.0 Product ordering information E A 3FCTR B 5FCTR C 8FCTR D 10FCTR E 12FCTR FCTR - C For example: 5FCTR2-CT W/ 30 D Outer jacket R=Thermoplastic; T=Fluorpolymer Tinned Copper Braid Supply Voltage 1= VAC; 2= VAC Type of cable Power in W/ at 10 C 3=12W/; 5=18W/; 8=25W/ 10=35W/; 12=42W/ C 20 B 10 A C Pipe temperature C Maximum length () vs. circuit breaker size Circuit Breaker Size Start-up Temperature 3FCTR 5FCTR 8FCTR 10FCTR 12FCTR 120V 120V 120V 120V 120V 40 C A 20 C C C C A 20 C C C C A 20 C C C C A 20 C C C F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

12 FATI-FCTP 1/2 FCTP Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over Itself (overlapped). Suitable for use in non-hazardous, hazardous and corrosive environments. FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive. Application FCTP is Industrial Rated approved self-regulating parallel heating cable, designed for pipe heat tracing in industrial applications, it is configured for use in hazardous and non-hazardous locations, including areas where corrosives may be present. It can provide process temperature maintenance up to 110 (230 ) and it can also be used for frost protection of large pipes and freeze protection in systems having high heat loss. Option FCTP C Tinned copper braid provide additional mechanical protection and a positive ground path. FCTP CR Flame retardant thermoplastic over jacket protect against certain inorganic chemical solutions, it also protect against abrasion and impact damage. FCTP CT High Temperature Fluoropolymer over jacket are used for exposure to organic or corrosive solutions or vapours may be present. Technical data Service voltage V, V Maximum maintain or continuous exposure temperature (power on) Maximum intermittent exposure temperature 1000 hours (power on or off) ( ) +135 (275 ) Tinned copper buswires 14 AWG/ Self-regulating semi-conductive core Inner insulation Tinned copper braid Minimum installation temperature -30 (-22 ) Protective braid resistance Bus wire gauge Approvals < 18.2Ω/km (17&31W/) 14 AWG (45&60W/) CE Optional outer jacket

13 FATI-FCTP 2/2 FCTP Dimension and weight Type Dimension Min.bending radius Weight (kg/100) FCTP C 12.0x4.4 26mm 9.5 FCTP CR 13.6x6.0 36mm 11.0 FCTP CT 12.4x4.8 28mm 13.9 Product ordering information Power output curves Nominal power output at when FCTP is installed on insulated pipes. FCTP - C For example: 5FCTP2-CT Outer jacket R=Thermoplastic; T=Fluorpolymer Tinned Copper Braid Supply Voltage 1= VAC; 2= VAC Type of cable Power in W/ at 10 C 5=10W/; 10=35W/ 15=48W/; 20=60W/ W/ D C B A 5FCTP B 10FCTP C 15FCTP D 20FCTP A C Pipe temperature C Maximum length () vs. circuit breaker size Minimum Start-up temperature -20 (-4 ) 10 (50 ) CB size Amps 5FCTP 10FCTP 15FCTP FCTP F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

14 FATI-FCTM 1/2 FCTM Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over Itself (overlapped). Suitable for use in non-hazardous, hazardous and corrosive environments. FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive. Application FCTM is self-regulating parallel heating cable (heating tape) can provides safe, reliable heat tracing for freeze protection or temperature maintenance of pipes, valves, flanges. It is suitable for use on small diameter plastic or mental pipes and instrument tubing in residential/light commercial and similar applications. Option FCTM C Tinned copper braid provide additional mechanical protection and a positive ground path. FCTM CR Flame retardant thermoplastic over jacket protect against certain inorganic chemical solutions, it also protect against abrasion and impact damage. FCTM CT High Temperature Fluoropolymer over jacket are used for exposure to organic or corrosive. Technical data Service voltage V, V Maximum maintain or continuous exposure temperature (power on) Maximum intermittent exposure temperature 1000 hours (power on or off) +65 (149 ) +85 (185 ) Minimum installation temperature -40 (-40 ) Tinned copper buswires 20 AWG Self-regulating semi-conductive core Inner insulation Tinned copper braid Optional outer jacket Protective braid resistance Bus wire gauge < 18.2Ω/km 20 AWG

15 FATI-FCTM 2/2 FCTM Dimension and weight Type Dimension Min.bending radius Weight (kg/100) FCTM C mm 29mm 6.0 FCTM CR mm 34mm 7.5 FCTM CT mm 30mm 7.1 Product ordering information FCTM - C For example: 5FCTM2-CR Power output curves Nominal power output at when FCTM is installed on insulated pipes 40 Outer jacket R=Thermoplastic; T=Fluorpolymer Tinned Copper Braid Supply Voltage 1= VAC; 2= VAC Type of cable Power in W/ at 10 C 3=15W/; 5=18W/ 8=28W/ W/m W/ C B A 3FCTM B 5FCTM C 8FCTM 10 A C Pipe temperature C Maximum length () vs. circuit breaker size Minimum Start-up temperature CB size Amps 3FCTM 5FCTM 8FCTM (50 ) (32 ) F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

16 FATI-FCTL 1/2 FCTL Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over itself (overlapped). Suitable for use in non-hazardous, hazardous and corrosive environments. FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive. Application FCTL is CE compliant self-regulating parallel heating cable (heating tape) is designed for residential and commercial metal and plastic pipe freeze protection and roof and gutter de-icing applications. It is ideal for use in maintaining fluid flow under low ambient. Freeze protection and low watt density process temperature systems such us pipelines, fire protection, process water, dust suppression systems, hot water and structure anti-icing are typical applications for this product. A UV stabilized thermoplastic elastomer overjacket is provided to cover the braid for wet applications and exposure to the sun. Option FCTL C FCTL CR Flame FCTL CT High Tinned copper braid provide additional mechanical protection and a positive groundpath. retardant thermoplastic overjacket protect against certain inorganic chemical solutions, it also protects against abrasion and impact damage. Temperature Fluoropolymer overjacket are used for exposure to organic or corrosive solutions or vapors may be present. Technical data Service voltage V, V Maximum maintain or continuous exposure temperature (power on) Maximum intermittent exposure temperature 1000 hours (power on or off) +65 (149 ) +85 (185 ) Minimum installation temperature -40 (-40 ) Protective braid resistance < 18.2Ω/km Tinned copper buswires Self-regulating semi-conductive core Inner insulation Tinned copper braid Optional outer jacket Bus wire gauge Approvals CE

17 FATI-FCTL 2/2 FCTL Dimension and weight Type Dimension Min.bending radius Weight (kg/100) Power output curves Nominal power output at when FCTL is installed on insulated pipes FCTL C mm 26mm 9.7 FCTL CR mm 36mm 11.0 FCTL CT mm 32mm 9.5 Product ordering information FCTL - C For example: 5FCTL-CR Outer jacket R=Thermoplastic; T=Fluorpolymer Tinned Copper Braid Supply Voltage 1= VAC; 2= VAC Type of cable Power in W/ at 10 C 3=10W/; 5=18W/ 8=27W/; 10=33W/ W/ D C B A A 3FCTL B 5FCTL C 8FCTL D 10FCTL C Pipe temperature C Maximum length () vs. circuit breaker size Circuit Breaker Size Start-up Temperature 3FCTL 5FCTL 8FCTL 10FCTL 120V 120V 120V 120V 40 C A 20 C C C C A 20 C C C C A 20 C C C C A 20 C C C F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

18 FATI-FCHW 1/2 FCHW Application FCHW self-regulating heating cable are installed on hot water supply pipes underneath standard pipe insulation.the heating cable replaces supply-pipe heating loses at the point where the heat loss occurs, thereby providing continuous, energy-efficient, hot water temperature maintainance and eliminating the need for a recirculation. Features Energy efficient, automatically varies its power output to compensate for variations in water temperature and ambient temperature. Easy to install, can be cut to any length (up to max. circuit length) required on site with no wasted cable. Lower installed cost than steam tracing, less maintenance expense and less downtime. No overheat or burnout even when wrapped over itself (overlapped). Low operating cost, the FCHW system continuously maintains hot water temperature at every point along the supply pipe. FCHW systems eliminate the need for designing complex recirculation systems, with their pumps, piping net-works, and complicated flow balancing. Immediate hot water when required Tinned copper buswires Self-regulating semi-conductive core Inner insulation Tinned copper braid Optional outer jacket

19 FATI-FCHW 2/2 FCHW Specifications MODEL FCHW-Y FCHW-O FCHW-R Jacket color Yellow Orange Red Bus wires Maintainance temperature 40 to to to 60 Max. exposure temperature 65 C 65 C C Nominal power output 7 W/ at 45 C 9 W/ at 55 C 12 W/ at 70 C Minimum bend radius 20mm 20mm 20mm Supply voltage 208~240V 208~240V 208~240V Maximum circuit length FCHW-Y FCHW-O FCHW-R Breaker size 13A A A F.A.T.I. Via A. Volta, Cusago (MI) heat.trace@fati.com

20 F.A.T.I. Srl Via Volta, Cusago (Milano - Italy) Tel Fax info@fati.com W W W. F A T I. C O M

120/240 Volts 3 Watt Floor Heating Cable System

120/240 Volts 3 Watt Floor Heating Cable System WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable

More information

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,

More information

Heating Cable. Cut to Length in Field. Description

Heating Cable. Cut to Length in Field. Description Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection

More information

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket SELF-REGULATING HEATING CABLE For pipe freeze protection and flow maintenance Heating cable construction Tinned-copper braid Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket Modified polyolefin

More information

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet

More information

INDUSTRIAL HEAT TRACE

INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE www.valin.com 800-774-5630 www.valin.com HTS-6 SERIES The HTS-6 commercial grade heater cable is designed for use in both indoor and outdoor locations as well

More information

Self-Regulating Freeze Protection Heating Cable

Self-Regulating Freeze Protection Heating Cable D PDS SRF Self-Regulating Freeze Protection Heating Cable E C B A Output Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Freeze Protection of

More information

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930 PRODUCT CODES NAMSR-Wattage-Voltage-Length. Ex: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly

More information

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930 PRODUCT CODES NAMSR-Wattage-Voltage-Length // eg: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly

More information

Product Overview. Application

Product Overview. Application Self-Regulating SC, SC/H Series-resistance heating cables for longline systems Electrical freeze protection for long pipelines in both nonhazardous and hazardous locations Power-Limiting Mineral Insulated

More information

Power-Limiting Cables

Power-Limiting Cables Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your

More information

Introduction to Heat Trace Cable Systems

Introduction to Heat Trace Cable Systems Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).

More information

Product Catalogue. Worldwide Specialists in Electric Heat Tracing. HTS THERMTRACE HTS THERMTRACE HTS T

Product Catalogue. Worldwide Specialists in Electric Heat Tracing.  HTS THERMTRACE HTS THERMTRACE HTS T Product Catalogue HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE www.hts-global.com is an international operating manufacturer of electric heating

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

Self-Regulating Cables

Self-Regulating Cables Self-Regulating 1. Self- Regulating 2. Power- Limiting This step-by-step design guide provides the tools necessary to design a self-regulating heat-tracing system for insulated pipes and tubing. For other

More information

SELF-REGULATING CABLES

SELF-REGULATING CABLES Self-Regulating SELF-REGULATING CABLES This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Self-regulating cables

Self-regulating cables Self-Regulating Self-regulating cables This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating

More information

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables... Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss

More information

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace pipe freeze protection or flow maintenance system. For

More information

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath Introduction to Heat Trace Cable Systems...6-2 Mineral Insulated Heat Trace Cable...6-2 Non-Metallic Sheath Heat Trace Cable...6-2 Installation Details...6-4 Engineering Guide for Mineral Insulated Cable...6-5

More information

FREEZSTOP MICRO SYSTEM

FREEZSTOP MICRO SYSTEM FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 25mm diameter water pipe at +5

More information

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system installation guide l 1 Uponor Ecoflex potable PEX plus pre-insulated pipe system

More information

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt. Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &

More information

Power Connection Kit installation instructions

Power Connection Kit installation instructions Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and

More information

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines PVC jacket - Deg C (optionally PUR material) Glass fibre thermal insulation Process tube(s) Heat reflective tape Electrical heating

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007) 1.0 SCOPE This specification outlines the minimum requirements for electrically traced or steam/fluid traced instrument

More information

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner

More information

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Heating systems protect pipes, valves, actuators and other elements vulnerable to harmful influence

More information

Heat Tracing Products

Heat Tracing Products Applications Electric Industrial Process Maintenance Applications Commercial Applications Chromalox heating cable line includes cables suitable for most process maintenance, pipe and vessel freeze protection

More information

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

3M Self Regulating Heating Cables

3M Self Regulating Heating Cables 2 Construction & Function 3M Self Regulating Heating Cables Introduction: 3M Canada and Thermon Manufacturing Company have entered into a strategic alliance to market the commercial line of heat tracing

More information

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series) PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire

More information

C A Heating Cable Gland Kit Installation Instructions

C A Heating Cable Gland Kit Installation Instructions C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

Electric Heat Tracing INSTALLATION PROCEDURES

Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing Complete Electric Heat Tracing System... Illustration A: Typical Heat Tracing Installation A complete electric heat tracing system will

More information

Self-Regulating Parallel Heating Cables. innovations in heat tracing

Self-Regulating Parallel Heating Cables. innovations in heat tracing Self-Regulating Parallel Heating Cables innovations in heat tracing ELSR Application Options The application options for the ELSR heating cables range from freeze protection to maintenance of pipes and

More information

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

INSTALLATION GUIDELINES. Design system and make a layout. For guidance, see attached layout and wiring diagram.

INSTALLATION GUIDELINES. Design system and make a layout. For guidance, see attached layout and wiring diagram. INSTALLATION GUIDELINES 1. Plan Design system and make a layout. For guidance, see attached layout and wiring diagram. Heating elements should be placed on top of the ice and water shield. Between the

More information

MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration

MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration MI Heating Cable HDPE jacketed, copper sheathed MI cable For surface snow melting in concrete, asphalt, and pavers Pipe Freeze Protection and Flow Maintenance Fire Sprinkler System Freeze Protection MI

More information

Heating Cable. Description

Heating Cable. Description Single Entry Power Connection Kit NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Lighted or Non-Lighted Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power, Splice or Tee Connection

More information

Electrical Trace Heating

Electrical Trace Heating Experts for your systems Electrical Trace Heating Quality Reliability Delivery reliability Our knowledge for your application Quintex GmbH i_park Tauberfranken 13 97922 Lauda-Königshofen Germany Tel: +49

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS CLOSED- AND OPEN-LOOP CONTROL SYSTEMS HEATERS WATER LEAKAGE DETECTION SYSTEMS

HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS CLOSED- AND OPEN-LOOP CONTROL SYSTEMS HEATERS WATER LEAKAGE DETECTION SYSTEMS HEATING TECHNOLOGY HEATING TECHNOLOGY HEATING TAPES/HEATING CABLE SYSTEMS 1 CLOSED- AND OPEN-LOOP CONTROL SYSTEMS 2 HEATERS 3 WATER LEAKAGE DETECTION SYSTEMS 4 PROJECT PLANNING INFORMATION 5 CONTENT

More information

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation

More information

Heating Cables Heating Tapes. innovations in heat tracing

Heating Cables Heating Tapes. innovations in heat tracing Heating Cables Heating Tapes innovations in heat tracing Table of Contents Introduction 3 Type ELP/SI Constant Wattage Heating Cable up to 200 C 4-5 Type ELP/SI-F Constant Wattage Heating Cable up to 200

More information

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

CAPABILITIES EXPERT TECHNICAL SUPPORT

CAPABILITIES EXPERT TECHNICAL SUPPORT Heat Trace Systems CAPABILITIES HEAT TRACE SOLUTIONS Cables Controllers Sensors Accessories EXPERT TECHNICAL SUPPORT Chromalox heat trace products and services save you time, reduce the cost of ownership,

More information

TSRT TSRT Tee Splice Kit Installation Instructions

TSRT TSRT Tee Splice Kit Installation Instructions TSRT TSRT Tee Splice Kit Installation Instructions Description The TSRS Splice Connection Kit is for use with all versions of EasyHeat s self regulating heater cables smaller than 0.44 (11mm) in diameter.

More information

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE For commercial and industrial applications Heating cable construction Insulation (magnesium oxide) Heating conductor Copper sheath HDPE

More information

Installation Devices 4

Installation Devices 4 Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex

More information

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions JBM-100-STB NEMA 4X-rated connection kit Installation Instructions Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box Approvals Hazardous Locations CLI,

More information

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A

More information

Installation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits.

Installation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits. Electrical tapes for sealing, insulation and bundling of cable and conduits. HellermannTyton offers a wide range of PVC and rubber tapes for sealing, insulation and bundling of cable and conduits. PVC-

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No PUR servo cables C-track compatible shielded Subject to technical modification 111600 Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR Use/Application/Properties Application Combined

More information

HTP PTP/ PTJ Power Connection Kit for Pipes

HTP PTP/ PTJ Power Connection Kit for Pipes HTP 1548-40PTP/1548-40PTJ Power Connection Kit for Pipes For use with Dekoron 2700 and 2300 Families of Heating Cables. 1548-81HTJ/81HTP for use with 2000 Series Heating Cables. Installation Instructions

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Solar Cable www.bericacavi.com www.fctsecuritycables.com SOLAR CABLE TINNED COPPER Outer sheath Insulation Conductor Conductors: fine wires stranded of tinned copper Cl. 5 CEI EN 60228 Insulation: 2Pfg

More information

TubeTrace Tubing Bundles

TubeTrace Tubing Bundles for Custom CEMS and Analytical Umbilicals English Units Receiving, Storing and Handling... 1. Inspect materials for damage incurred during shipping. Report damages to carrier for settlement. 2. Identify

More information

H900 WinterGard Power Connection Kit with End Seal Installation Instructions

H900 WinterGard Power Connection Kit with End Seal Installation Instructions H900 WinterGard Power Connection Kit with End Seal Installation Instructions Power connection for H311, H611, and H621 Power connection for H612 and H622 Description The WinterGard power connection kit

More information

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES HIGH TEMPERATURE CABLES C O N T E N T S DEF 61-12 Part 18 Type 1 LFH Equipment Wires :2 Technical Information for DEF 61-12 :8 PTFE Insulated Equipment Wire Single Core :10 PTFE EFGLAS Aircraft Cable :12

More information

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating

More information

Heating Cable. Construction

Heating Cable. Construction MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)

More information

FLEXTRACE. FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration. Applications. Characteristics

FLEXTRACE. FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration.   Applications. Characteristics FSG.GB/07/05.07 FLEXTRACE TEMPERATURE MAINTENANCE SYSTEMS www.flexelec.com FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration Characteristics Can be cut to length on site. Will not

More information

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS DESCRIPTION The JBS-100-A and JBS-100-A6 are NEMA 4X-rated power connection kit. It is designed for use with Raychem

More information

Self-regulating frost protection system for pipes

Self-regulating frost protection system for pipes AT-TS-13 60 30 90 0 C 120 Self-regulating frost protection system for pipes eliability: protects your pipes from frost damage Maintenance-free Efficient energy use FS-A-2X: 10 W/m at 5 C FS-B-2X: 26 W/m

More information

Data sheet chainflex CF310.UL

Data sheet chainflex CF310.UL 1. Outer jacket: Pressure extruded, flame-retardant TPE mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Core insulation: Mechanically

More information

Data sheet chainflex CF886

Data sheet chainflex CF886 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Conductor

More information

Heating Cable. Description

Heating Cable. Description 203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal

More information

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG COMPANY OVERVIEW Since 1970, we have been pioneering new developments in heater technology and providing

More information

THERMOCOUPLE CABLES THERMOELECTRICITY

THERMOCOUPLE CABLES THERMOELECTRICITY THERMOCOUPLE CABLES THERMOELECTRICITY When a metallic conductor is exposed to a difference of temperature between the two extremities, an electromotive force (emf) is generated by the temperature gradient,

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

RT FlexiPanel TM Tank and Vessel Heating Panel

RT FlexiPanel TM Tank and Vessel Heating Panel RT FlexiPanel TM Tank and Vessel ing Panel Application... Metallic Tank and Vessel ing The RT FlexiPanel is a self-contained, high performance flexible heating panel designed specifically for use on metallic

More information

Data sheet chainflex CF340

Data sheet chainflex CF340 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Core insulation: Mechanically

More information

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022

More information

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information

More information

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is

More information

Installation Instructions

Installation Instructions K-Series Constant-Wattage Heating Cable Installation Instructions Read and understand this material before installing this heater. Failure to understand how to safely install the heater could result in

More information

XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES cable construction Corrugated stainless steel 316L outer sheath Insulation (magnesium oxide) conductors (dual)

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

ELSR Electric Self-Regulating Parallel Heating Cables

ELSR Electric Self-Regulating Parallel Heating Cables ELSR Electric Self-Regulating Parallel Heating Cables www.hazlocheaters.com www.eltherm.ca 1 Eltherm, a German manufacturer, and Hazloc Heaters (part of The Ouellet Canada Group) have formed a strategic

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for

More information