CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Size: px
Start display at page:

Download "CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems"

Transcription

1 Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR CF LC CF LC.D.PVC.022.PUR CF LC.022 Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 1/6

2 Core design: Conductor Core insulation.pvc.pur.d Core identification: 2 data cores 4 data cores* No. Colour No. Colour 01 white 01 white 02 brown 02 brown 03 green 04 yellow * Star quad design Core identification (clockwise): white, green, brown, yellow. Shield design: Material Shield coverage.pvc Bending-stable braid made of tinned Linear: approx. 50 % Optical: approx. 80 %.PUR Bending-stable braid made of tinned Linear: approx. 50 % Optical: approx. 80 % Extremely bendingstable braid made of tinned Linear: approx. 70 % Optical: approx. 90 % Extremely bendingstable braid made of tinned Linear: approx. 70 % Optical: approx. 90 %.D Extremely bendingstable braid made of tinned Linear: approx. 70 % Optical: approx. 90 % Torsion-stable braid made of tinned Linear: approx. 65 % Optical: approx. 85 % Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 2/6

3 Jacket design:.pvc.pur Inner jacket None None Outer jacket on the basis of PVC DIN VDE ), abrasion- and on the basis of PUR DIN VDE ), highly abrasion- and bendingstable, adapted to suit the adapted to suit the adapted to suit the.d adapted to suit the Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 3/6 None 3D - of the outer jacket:.pvc.pur.d oil-resistant DIN EN DIN EN DIN EN DIN EN DIN EN DIN EN biooil -resistant - - VDMA with Plantocut 8 S-MB tested by DEA VDMA with Plantocut 8 S-MB tested by DEA VDMA with Plantocut 8 S-MB tested by DEA PVC- / halogen-free - / / - / / / - hydrolysis- / microberesistant - / / / / / MUD-resistant - NEK status NEK status 2009 flame-retardant - clean room (DIN ISO ) Class 1 Class 1 Class 1 Class 1 Class 1 Class 1 silicon-free lead-free 2011/65/EU (RoHS-II) 2011/65/EU (RoHS-II) 2011/65/EU (RoHS-II) 2011/65/EU (RoHS-II) 2011/65/EU (RoHS-II) 2011/65/EU (RoHS-II) UV-resistant Medium Medium Medium High Medium High Cable marking: Colour outer jacket.pvc.pur Steel blue (similar to RAL 5011).D Steel blue (similar to RAL 5011) Colour of the cable marking Black Black Black White Black White DESINA - - -

4 Cable marking (Black or White): m ** igus chainflex CF CE CAN-Bus conform RoHS-II conform +++ chainflex cable works +++ ** Length printing: Not calibrated. Only intended as an orientation aid. / : Cable identification according to part no. (see technical table for details). : Printing of the UL-Style (only if UL-certifying exists). : Printing: Low Capacitance (only &.D). : Printing: DESINA (only if DESINA-standard fulfilled). General mechanical values: (For individual details see technical table and/or the own data sheet belonging to the cable type) Minimum bending within the application Temperature range moved Torsion (at 1 m cable length).pvc Ex.:.020: m ** igus chainflex.020 (4x0,25)C E cя Uus AWM Style VW-1 AWM I/II A/B 80 C 30 V FT-1 CE DESINA CAN-Bus conform RoHS-II conform +++ chainflex cable works +++ Ex.: CF LC: m ** igus chainflex CF LC (2x0,5)C CE Low Capacitance CAN-Bus conform RoHS-II conform.pur +++ chainflex cable works +++.D 12,5 x d 12,5 x d 10 x d 10 x d 10 x d 10 x d -5 C to +70 C (+23 F to +158 F) -20 C to +70 C (-4 F to +158 F) -35 C to +70 C (-31 F to +158 F) -35 C to +70 C (-31 F to +158 F) -35 C to +70 C (-31 F to +158 F) -25 C to +70 C (-13 F to +194 F) ±30 ±30 ±30 ±30 ±30 ±180 General electrical values: (For individual details see technical table and/or the own data sheet belonging to the cable type).pvc.pur.d Nominal voltage 50 V 50 V 50 V 50 V 50 V 50 V Certifications Guidelines 1598 & 2571, CE, NFPA, EAC & TR (CTP) 1598 & 20236, CE, DESINA, NFPA, EAC & TR (CTP) 1589 & 21371, CE, DESINA, NFPA, EAC & TR (CTP) & 20236, CE, EAC CE, DESINA, EAC CE, NFPA, EAC Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 4/6

5 Dynamic values: Max. speed for e-chain use:*** Max. speed within the application:*** Max. acceleration within the application:***.pvc.pur.d Unsupported v = 3 m / s v = 3 m / s v = 10 m / s v = 10 m / s v = 10 m / s v = 10 m / s Gliding v = 2 m / s v = 2 m / s v = 6 m / s v = 6 m / s v = 6 m / s v = 2 m / s Typical lab test setup for the e-chain cable groups: v = 10 m / s a = 30 m / s 2 a = 30 m / s 2 a = 100 m / s 2 a = 100 m / s 2 a = 100 m / s 2 a = 10 m / s 2.PVC.PUR.D Test bending radius R approx. 100 mm approx. 100 mm approx mm approx. 75 mm approx mm Test travel S approx m approx m approx m approx m approx m Test period Test speed approx. 0,5-2 m / s approx. 0,5-2 m / s approx. 0,5-2 m / s approx. 0,5-2 m / s approx. 0,5-2 m / s Test acceleration approx. 0,5-1,5 m / s 2 approx. 0,5-1,5 m / s 2 approx. 0,5-1,5 m / s 2 approx. 0,5-1,5 m / s 2 approx. 0,5-1,5 m / s 2 *** These values are based on specific applications or tests. They do not represent the limit of what is technically feasible. Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 5/6

6 Technical tables: Mechanical values: Electrical values: Part no. Number of cores & nominal cross section [mm²] External diameter (d)**** [max. mm] Copper index [kg / km] Weight [kg / km].pvc.021 (2x0,5)C 8, PVC.022 (4x0,5)C***** 8, PUR.021 (2x0,5)C 8, PUR.022 (4x0,5)C***** 8, (4x0,25)C***** 6, (2x0,5)C 8, (4x0,5)C***** 8, CF LC (2x0,5)C 8, CF LC (4x0,5)C***** 8, CF LC.D (4x0, 25)C***** 6, CF LC.D (2x0,5)C 8, (4x0,5)C***** 7, **** External diameters are maximum values and may tend toward lower tolerance limits. ***** Star quad design Nominal cross section [mm²] Conductor resistance [approx. Ω / km] at 20 C Max. current rating [A] at 30 C ) DIN IEC DIN VDE , , The max. current rating depends on factors such as the individual environmental conditions and the type of installation. Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 6/6

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044 for medium to high load requirements. Overview Class.PVC.PUR (3D-e-chain - cable) CAT5 (4x0,25)C (4x(2x0,25))C.PVC.040.PUR.040.040 CF14.02.02.02.CAT5 34 mm.041 CF14.02.04.02.CAT5 (5x(2x0,25))C 34 mm igus

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

CF270.UL.D.

CF270.UL.D. Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:

More information

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see

More information

CF11.LC / CF11.LC.D CF14.CAT5

CF11.LC / CF11.LC.D CF14.CAT5 TPE - e-chain - Bus cable for maximum load requirements (Class 6.6.4): shielded, oil- and biooil-resistant, PVC- and halogen-free as well as hydrolysis- and microbe-resistant. Overview Example drawing

More information

Data sheet chainflex CF310.UL

Data sheet chainflex CF310.UL 1. Outer jacket: Pressure extruded, flame-retardant TPE mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Core insulation: Mechanically

More information

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table) Outer jacket: Pressure extruded PVC mixture Inner jacket: Pressure extruded, gusset filling PVC mixture Conductor: Fine-wire strand consisting of bare copper wires 6 1 Core insulation: Mechanically highquality

More information

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm Overview Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF898.001 CF898.045 CF898.080 & CF898.081 Example drawing 34 mm Core design: Conductor: Core insulation: Core identification:

More information

Data sheet chainflex CF886

Data sheet chainflex CF886 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Conductor

More information

CFRIP - tear strip for faster stripping

CFRIP - tear strip for faster stripping Outer jacket: Pressure extruded, gusset filling, flame-retardant TPE mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand in especially bendingstable

More information

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see the

More information

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF270.UL.D For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core

More information

Data sheet chainflex CF881

Data sheet chainflex CF881 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Stranded

More information

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table) Outer jacket: Pressure extruded, gusset filling PVC mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand consisting of bare copper wires Core insulation:

More information

Data sheet chainflex CF340

Data sheet chainflex CF340 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Core insulation: Mechanically

More information

Data sheet chainflex CF300.UL.D

Data sheet chainflex CF300.UL.D 1. Outer jacket: Pressure extruded, flame-retardant TPE mixture 2. Core insulation: Mechanically high-quality TPE mixture 3. Conductor: Conductor rope in especially bending-stable version consisting of

More information

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant. Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire

More information

Data sheet chainflex CF6

Data sheet chainflex CF6 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture

More information

Data sheet chainflex CF140.UL

Data sheet chainflex CF140.UL 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip

More information

Data sheet chainflex CF886

Data sheet chainflex CF886 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Shield foil: Aluminium clad plastic foil 4. Banding: Plastic foil 5. Filling: Plastic yarns 6.

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

Data sheet chainflex CF885.PE

Data sheet chainflex CF885.PE 1. Outer jacket: Pressure extruded PVC mixture 2. Core insulation: Mechanically high-quality PVC mixture 3. Conductor: Conductor consisting of bare copper wires For detailed overview please see design

More information

Data sheet chainflex CF330.D

Data sheet chainflex CF330.D 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Core insulation: Mechanically high-quality TPE mixture 3. Conductor: Conductor rope in especially bending-stable version consisting of bare

More information

Data sheet chainflex CF10

Data sheet chainflex CF10 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Extremely bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling TPE mixture

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

DNV-GL HH CE RoHS-II conform

DNV-GL HH CE RoHS-II conform Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable

More information

Data sheet chainflex CFSOFT1

Data sheet chainflex CFSOFT1 to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture

More information

Data sheet chainflex CF5

Data sheet chainflex CF5 1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:

More information

Data sheet chainflex CF130.UL

Data sheet chainflex CF130.UL 1. Outer jacket: Pressure extruded, gusset-filling PVC mixture 2. CFRIP: Tear strip for faster cable stripping 3. Core insulation: Mechanically high-quality TPE mixture 4. Conductor: Fine-wire strand consisting

More information

Min. bending radius for fixed installation 7,5 x d 6,8 x d 4,0 x d 6,8 x d Torsion (at 1 m cable length) --- ±45 ±90 ±45

Min. bending radius for fixed installation 7,5 x d 6,8 x d 4,0 x d 6,8 x d Torsion (at 1 m cable length) --- ±45 ±90 ±45 Outer jacket: Pressure extruded, gusset filling, oil-resistant PVC mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand consisting of bare copper

More information

Data sheet chainflex CF113.D

Data sheet chainflex CF113.D For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Banding: Plastic fleece 3. Overall shield: Extremely bending-stable braid made of tinned copper wires 4.

More information

Data sheet chainflex CF9

Data sheet chainflex CF9 1. Outer jacket: Pressure extruded, gusset-filling, halogenfree TPE mixture 2. CFRIP: Tear strip for faster cable stripping 3. Core insulation: Mechanically high-quality TPE mixture 4. Conductor: Stranded

More information

us cables New! chainflex guarantee club Guaranteed lifetime Selection table page 154 CFBUS.PVC PVC 12,5-5/

us cables New! chainflex guarantee club Guaranteed lifetime Selection table page 154 CFBUS.PVC PVC 12,5-5/ chainflex type chainflex cable Jacket Shield Min. bending radius, moved [factor x d] Temperature, moved from/to [ C] Approvals and standards Oil-resistant Torsion resistant v max. [m/s] unsupported v max.

More information

Special cables. Guarantee. Special cables

Special cables. Guarantee. Special cables Special cables chainflex cable Special cables CFTHERMO Thermocouple cable 384 CFFLAT Single core flat cable 386 CFBRAID Braided conductors 388 CFSPECIAL.182 Cables for hanging applications 390 CFSPECIAL.414

More information

Cables up to CAT7.

Cables up to CAT7. thernet Cables up to CAT7 www.igus.eu/ethernet Cost down...... Service life up For all data volumes and types of movement... ing your machine with cables. The cheapest cable that is guaranteed to work.

More information

Guarantee. Special cables

Guarantee. Special cables Special cables Chainflex cable Approvals and standards Page Special cables CFTHERMO Thermocouple cable 400 CFFLAT Single core flat cable 402 CFBRAID Braided conductors 404 CFSPECIAL-182 Cables for hanging

More information

chainflex cable Servo cables CF887 PVC 15 +5/ CF210.UL PVC 10 +5/ CF220.UL.H PVC 10 +5/

chainflex cable Servo cables CF887 PVC 15 +5/ CF210.UL PVC 10 +5/ CF220.UL.H PVC 10 +5/ chainflex cable Jacket Shield Bending radius min., e-chain e-chain Approvals and standards Oil-resistant Torsion resistant v max. [m/s], unsupported v max. [m/s] gliding a max. [m/s 2 ] Servo cables Page

More information

Cables up to CAT7.

Cables up to CAT7. thernet Cables up to CAT7 www.igus.eu/ethernet Cost down...... Service life up For all data volumes and types of movement... Networking your machine with cables. The cheapest cable that is guaranteed to

More information

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No PUR servo cables C-track compatible shielded Subject to technical modification 111600 Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR Use/Application/Properties Application Combined

More information

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application

More information

Cables up to CAT7.

Cables up to CAT7. thernet Cables up to CAT7 www.igus.eu/ethernet Cost down...... Service life up For all data volumes and types of movement... Networking your machine with Ethernet cables. Always find the right Ethernet

More information

Fibre optic cables. Guarantee. Fibre optic cables. Information about Fibre optic cables CFLK CFLG88 CFLG.LB.PUR CFLG.LB CFLG.G

Fibre optic cables. Guarantee. Fibre optic cables. Information about Fibre optic cables CFLK CFLG88 CFLG.LB.PUR CFLG.LB CFLG.G Page [m/s2] v max. [m/s] gliding v max. [m/s]. unsupported Torsion resistant Oil-resistant Approvals and standards Temperature. e-chain Minimum bend radius. e-chain Jacket chainflex cable Fibre optic cables

More information

chainflex cables with DNV-GL certification ndustry plastics for longer life

chainflex cables with DNV-GL certification ndustry plastics for longer life ffshore chainflex cables with DNV-GL certification ndustry plastics for longer life...... www.igus.eu/offshore... 348 chainflex cables...... with GL-DNV approval chainflex cables Jacket material Shielded

More information

chainflex cable Servo cables Exclusive! chainflex guarantee guaranteed lifetime Selection table page 268 CF887 PVC 15 +5/

chainflex cable Servo cables Exclusive! chainflex guarantee guaranteed lifetime Selection table page 268 CF887 PVC 15 +5/ chainflex types Servo cables chainflex cable Servo cables Jacket Shield Bend radius min., e-chain [factor x d] Temperature, e-chain from/to [ C] Approvals and standards Exclusive! chainflex guarantee guaranteed

More information

Special cables. chainflex Typees. chainflex

Special cables. chainflex Typees. chainflex chainflex Typees Special cables chainflex cable Special cables CFTHERMO Thermocouple cable 406 CFTHERMO Thermocouple cable - ready-made 408 CFFLAT Single core flat cables 410 CFBRAID Braided cores 412

More information

Chainflex cable. Bus cables. Exclusive! Chainflex guarantee guaranteed lifetime Selection table page 174. Information Chainflex Ethernet cables

Chainflex cable. Bus cables. Exclusive! Chainflex guarantee guaranteed lifetime Selection table page 174. Information Chainflex Ethernet cables types cable Jacket Shield Bend radius min., E-Chain [factor x d] Temperature, E-Chain from/to [ F] Approvals and standards oil-resistant torsion resistant v max. [ft/s] unsupported v max. [ft/s] gliding

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

chainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life

chainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life ffshore chainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life...... www.igus.eu/offshore... 348 chainflex cables with Germanischer Lloyd approval chainflex cables Jacket

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,

More information

chainflex type Fibre optic cables* Information fibre optic cables 154 CFLK** PUR 12,5-20/ CFLG.2H CFLG.LB*** TPE 5-40/

chainflex type Fibre optic cables* Information fibre optic cables 154 CFLK** PUR 12,5-20/ CFLG.2H CFLG.LB*** TPE 5-40/ chainflex type ibre optic cables chainflex cable Information fibre optic cables 154 CFLK** PUR 12,5-20/ +70 10 5 20 156 CFLG.2H Jacket Fibre optic cables* Shield Min. bending radius, moved [factor x d]

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

chainflex readycable Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable TPE 260

chainflex readycable Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable TPE 260 Camera Video-/vision-/bus technology chainflex readycable Cable type Jacket Page Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable 260 USB Ready-made cable 264

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation

More information

Test-Order chainflex

Test-Order chainflex page 1 of 7 Test No.: 4404 Test Intention: In test 4404 we will investigate the lifespan of CF270.UL.D in an E6.52.075.125.0 echain. Client: Name: Christian Mittelstedt Team: chainflex Date: 06.03.2012

More information

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 110 H Info Benefits Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

PVC motor cables unshielded

PVC motor cables unshielded PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

INFORMATION. Hybrid cables. Description

INFORMATION. Hybrid cables. Description Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr For

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

PUR c-track cables For highest requirements

PUR c-track cables For highest requirements 2. C-track cables PUR c-track cables For highest requirements LÜTZE SUPERFLEX PLUS N PUR UL 300 V Machine and device construction, transport and conveyor technology Through full PUR jacket and TPE conductor

More information

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation

More information

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands Lapp Kabel, power and control cable, PVC single core for field wiring, UL MTW VW-1, UL AWM style

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath Spiral cable with outer PUR sheath for exact impulse transmission, unshielded - PUR spiral cable, abrasion-resistant data and control cable for use in data processing, measurement and control engineering

More information

SAC-4P-M12MS/ 5,0-PUR SH

SAC-4P-M12MS/ 5,0-PUR SH Extract from the online catalog SAC-4P-M12MS/ 5,0-PUR SH Order No.: 1682647 Sensor/Actuator cable, 4-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Plug, straight M12, A-coded, on Free conductor

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY industrieblick / Fotolia Content page Who we are............................................................................................................

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12 to RJ45 Ethernet connection line Cat.5, 4-pole, D-coded (IEC 61076-2-101) M12

More information

Industrial Ethernet Cables

Industrial Ethernet Cables Industrial Ethernet Cables www.sab-worldwide.com INDUSTRIAL ETHERNET CABLES Content page Application of Industrial ETHERNET Cables.........................................................................................

More information

Cable Assemblies according to Bosch Rexroth Standard

Cable Assemblies according to Bosch Rexroth Standard Connectivity Solutions Cable Assemblies according to Bosch Rexroth Standard Copyright Protected trademarks and trade names are not always labelled as such in this publication. This does not mean they are

More information

RFOU 0.6/1kV Power Cable

RFOU 0.6/1kV Power Cable RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

BFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency

More information

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification shielded M12 to RJ45 Ethernet connection line Cat.5, 4-pole, D-coded (IEC 61076-2-101)

More information

Approvals (Norm references)

Approvals (Norm references) ÖLFLEX ROBUST 200 Robust and weatherproofed Wide range of application opportunities Machine tool manufacture, medical technology, laundries, car washing equipment, chemical industry, composting plants,

More information

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION H07V-K GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,

More information

SAC-5P-3,0-PUR/M12FS SH

SAC-5P-3,0-PUR/M12FS SH Extract from the online catalog SAC-5P-3,0-PUR/M12FS SH Order No.: 1682948 Sensor/actuator cable, 5-pos., PUR halogen-free black, shielded, free conductor end on straight M12 socket, cable length: 3 m

More information

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/ Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection line Cat.5e, 4-pole, D-coded to IEC 61076-2-101 straight

More information