6

7

8

9

10 Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation (VW-1). Temperature rating 90C in wet and dry location. Switchboard Wire UL Type SIS 600 Volt Copper STANDARDS: UL 44 C(UL) US: CSA/UL Listed Flame Rated: UL 1581 Vertical Flame (VW1) (#14 and larger) ROHS Compliant Dual Rated Type XHHW-2 (#14 & larger) (UL 66 Fixture Wire for #16 AWG) Per ICEA S / NEMA WC-70 Gasoline and Oil Resistant II Sunlight Resistant Excellent crush and abrasion resistance -40 C rated Federal Spec AA Flex-Strand Catalog Number Size AWG or KCMIL Flex-Strand Stock Stranding Class B Stock Class C Stock Insulation Thickness (mils) Nominal Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30ºC Ambient) 90ºCWet/Dry SIS16KT 16 *** SIS14KTVW ** SIS12KTVW ** SIS10KTVW ** SIS8HTVW SIS6HTVW COLOR CHART Size Blue Black Brown Green Gray Orange Red White Yellow 16 X X 14 X X X X X X X X 12 X X X X X X X 10 X 8 X 6 X *Per NEC Table ** The overcurrent protection for items marked ** shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC footnote. ***#16 AWG is not recognized as Type SIS or XHHW-2. This conductor will carry one or more of the following listings: FFH-2, RFH-2, RFFH-2, RFHH-3 NOTE: Copper Conductor available Non-Tinned. NOTE: The data shown is approximate and subject to standard industry tolerances Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

11

12

13

14

15 Manufacturing quality. Delivering service. Available with tinned conductors. Description: Single conductor, stranded copper, insulated with heat and moisture resistant, cross-linked polyethylene insulation, (Type XHHW- 2), with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead jacket. EnviroPlusTM Power Cable 600 Volt Single Conductor Power Cable XHHW-2 Zero Halogen, Limited Smoke Jacket Standards: LS and CT Rated 1/0 and larger per UL1685 Conductors UL44 ICEA S /NEMA WC-70 IEEE ,000 BTU flame test 1/0 and larger Federal spec A-A UL Listed construction Temperature Rating: 90 C Wet/Dry Sunlight resistant; superior water resistance Excellent crush and abrasion resistance Zero Halogen, Limited Smoke Jacket, -40 C Single Conductors Size AWG or MCM Strand (no.) Insulation Thickness (mils) Jacket Thickness (mils) Nominal Diameter Overall (inch) Approx. Net Weight per 1000 feet (lbs.) Ampacity* 30 C Ambient 90 C Wet/Dry / / / / *Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG and 30 amps for 10 NOTE: The data shown is approximate and subject to standard industry tolerances Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

16 Manufacturing quality. Delivering service. Single Conductors Description: Single conductor insulated with heat and moisture resistant, cross-linked polyethylene insulation, (Type USE-2), with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead jacket. Tinned conductors available. EnviroPlusTM Photovoltaic Cable 1000 Volt Single Conductor Power Cable USE-2 or RHH or RHW-2 Zero Halogen, Limited Smoke Jacket Standards: UL Listed as Type PV Cable Conductors UL854 (#16 per UL 66) ICEA S /NEMA WC-70 Flame Rated: VW-1 per UL 1685 Temperature Rating: 90 C Wet/Dry Sunlight resistant; superior water resistance Excellent crush and abrasion resistance -40º C Cold Bend and Cold Impact Zero Halogen, Limited Smoke Jacket Size AWG or MCM Strand (no.) Insulation Thickness (mils) Jacket Thickness (mils) Nominal Diameter Overall (inch) Approx. Net Weight per 1000 feet (lbs.) Ampacity* 30 C Ambient 90 C Wet/Dry *Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG and 30 amps for 10. NOTE: The data shown is approximate and subject to standard industry tolerances Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38 Manufacturing quality. Delivering service. ServiceDrive ASD/VFD Shielded Tray Drive Cable PVC Jacket Overall Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 May be used in ASD / VFD applications Standards: UL 1277 Flame Rated: IEEE 383 (70,000 BTU), ICEA T (210,000 BTU) on 1/0 and larger IEEE 1202 / CSA FT-4 Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II Jacket Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S / NEMA WC-70 Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30 C Ambient Wet/Dry) THREE CONDUCTOR # # # # # # # # , # , / # , / # , / # , / # , # , # , # , / , / , *Per NEC Table **Fillers used when required. + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC footnote. Note: The data shown is approximate and subject to standard industry tolerances. August 2007 Made in the USA Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

39 Manufacturing quality. Delivering service. ServiceDrive Plus ASD/VFD Shielded Tray Drive Cable Factory Mutual Group 1 Listed, Zero Halogen, Limited Smoke, Lead Free, Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black zero-halogen, limited smoke, zero lead jacket. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 May be used in ASD / VFD applications Standards: UL 1277 Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202 / CSA FT-4, UL 1685 LS Factory Mutual Group 1 Listed Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial Color Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S / NEMA WC-70 Zero Halogen, Limited Smoke, -40C Open wiring (Exposed Runs) 4 AWG and larger Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30 C Ambient Wet/Dry) THREE CONDUCTOR # # # # # # # # , # , / # , / # , / # , / # , # , # , # , / , / , *Per NEC Table **Fillers used when required. ***Cables marked for open wiring / exposed runs must contain a ground wire + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC footnote. Note: The data shown is approximate and subject to standard industry tolerances. August 2007 Made in the USA Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

40

41

42 Manufacturing quality. Delivering service. Description: 3 or 4 conductors, stranded, insulated with heat & moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** & green or bare ground conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor. Jacket upon request. Standards: UL 1569, ICEA S /NEMA WC-70 NEC Article 330 Cable Tray Rated 600 Volt, 90 C rated dry locations (Wet/Dry with Jacket) Color coding: Black and Numbered with a Green Ground 1/0 AWG and larger: Black and Numbered with a Bare Ground Size AWG or MCM Strand (no.) Insulation Thickness (mils) Insulated Copper Grounding Conductor(s) (AWG) (Green) Feeder Size MC Cable 600V / UL Type MC Galvanized Steel or Aluminum Copper XHHW-2 Applications Service Wire s Feeder Size MC cable is designed to be a cost effective replacement for conduit & wire. Suitable for service, branch & feeder circuits. Ideal for use in commercial, industrial & utility applications. This flexible cable assembly offers: labor/time savings, an increased resistance to mechanical damage, system design flexibility & the reliability of a factory assembled & tested cable system. Features Suitable for use in NEC hazardous locations: Class I, Div. 2 Class II, Div. 2 Two-hour Firewall rated, (2/0 AWG and smaller) For use in Theatres (Article 520), Motion Picture & TV Studios (Article 530) & Places of Assembly with more than 100 people Can be messenger supported (Article 330) Diameter over Armor (inch) Approx. Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor Ampacity* (30 C Ambient Wet/Dry) 90 C Armor Cables TWO FOUR CONDUCTOR THREE CONDUCTOR / *** / *** / *** / *** *** *** *** *** *** *** *** / *** / *** / *** / *** *** *** *** *** *** *** *** ,250 11, *Per NEC Table **Fillers used when required. *** Bare Copper Grounds. NOTE: The data shown is approximate and subject to standard industry tolerances. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

43

44 Manufacturing quality. Delivering service. Description: 3 or 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** and bare copper ground conductor(s). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant black PVC jacket. Jacket available under armor and in other colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2 Class II, Div. 2 THREE CONDUCTOR Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) Diameter over Armor (inch) Interlocked Armor 600 Volt UL Type MC Galvanized Steel or Aluminum Copper XHHW-2 Standards: UL 1569 Flame Rated: IEEE-383 (70,000 BTU), ICEA T (210,000 BTU), IEEE 1202/CSA FT-4 Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Color Code Black and Numbered / other color codes available Temperature rating at 90 C Wet/Dry ICEA S /NEMA WC-70 PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor Ampacity* (30 C Ambient Wet/Dry) # # # # # # / # / # / # / # # # # # # # # C Armor Cables FOUR CONDUCTOR # # # # # # / # / # / # / # # # # # # # # *Per NEC Table Includes encasement in concrete. **Fillers used when required. NOTE: The data shown is approximate and subject to standard industry tolerances. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

45

46

47

48 Manufacturing quality. Delivering service. ServiceDrive ASD/VFD Shielded Interlocked Armor Drive Cable PVC Jacket Overall Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers** and 3 bare copper ground conductors. Cable core covered with binder tape, 5-mil helical copper tape shield, galvanized steel interlocked armor, with flame and sunlight resistant PVC jacket overall. Jacket available in colors. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 Suitable for ASD / VFD applications Standards: UL 1569 Flame Rated: IEEE 383 (70,000 BTU), ICEA T (210,000 BTU), IEEE 1202 / CSA FT-4 Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial 1 Oil Resistant II Jacket Color Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S / NEMA WC-70 THREE CONDUCTOR Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) Diameter over Armor (inch) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) (Galvanized) Ampacity* (30 C Ambient Wet/Dry) # # # # # # # # # / # / # / # / # # # # / / C *Per NEC Table Includes encasement in concrete. + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC footnote. Note: For VFD / ASD applications, galvanized armor should be preferred (for magnetic noise reduction). Note: The data shown is approximate and subject to standard industry tolerances Made in the USA Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

49 Manufacturing quality. Delivering service. ServiceDrive Plus ASD/VFD Shielded Interlocked Armor Drive Cable Factory Mutual Group 1 Listed, Zero Halogen, Limited Smoke, Lead Free Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 bare copper ground conductors. Cable core covered with binder tape, 5-mil helical copper tape shield, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant zero halogen, limited smoke, zero lead jacket overall. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 Designed exclusively for ASD / VFD applications. Standards: UL 1569 Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202 / CSA FT-4, UL 1685 LS Factory Mutual Group 1 listed Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial 1 Color Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S / NEMA WC-70 Zero Halogen, Limited Smoke Jacket, -40C THREE CONDUCTOR Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) Diameter over Armor (inch) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30 C Ambient Wet/Dry) 90 C # # # # # # # # # / # / # / # / # # # # / / *Per NEC Table Includes encasement in concrete. + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC footnote. Note: For VFD / ASD applications, galvanized armor should be preferred (for magnetic noise reduction). Note: The data shown is approximate and subject to standard industry tolerances 2007 Made in the USA Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

50

51

52

53

54

55

56

57

58

59

60

61

62 Manufacturing quality. Delivering service. Submersible Pump Cable TYPE THW-Heavy Duty FLAT BLACK JACKETED with Ground 75 C/600V Description & Features: UL listed Type THW heavy duty flat submersible pump cable is a multi-purpose cable with parallel, individually insulated, color coded conductors and an overall jacket. Construction provides flexible copper stranding insulated with Type THW (PVC) compound. A tough PVC jacket, with a non-penetrating web, is easily stripped to facilitate installation yet provide optimum flexibility, mechanical protection and crush resistance. UL listed as Type THW Submersible Pump Cable Acid, alkali, oil and grease resistant Weather, ozone and sunlight resistant jacket Abrasion and crush resistant Sequential footage marks Applications: For use within the well casing to supply power to the submersible pump Designed for use where extra mechanical protection and flexibility during installation and operation are required Construction: Conductors: Flexible stranded soft annealed copper Insulation: Thermoplastic polyvinyl chloride (PVC) Color coding: black, red, yellow, green (ground) Assembly: The insulated conductors, including the grounding conductor, are configured flat and parallel without fillers Jacket: Black thermoplastic polyvinyl chloride (PVC) applied directly over the conductors with a non-penetrating web Temperature: 75 C Voltage: 600 Volts Specifications & Standards: UL Standard 83 TWO OR THREE CONDUCTORS WITH GREEN INSULATED GROUNDING CONDUCTORS Conductor Size, AWG Dimensions (Inches) Standard Ampacity Weight Item Code Power Ground Insulation Jacket O.D. Packaging NEC (Lbs./Mft.) PMP12/2GGHD 12/2 (19 str) 12 (19 str) x & PMP10/2GGHD 10/2 (19 str) 10 (19 str) x & PMP14/3GGHD 14/3 (7 str) 14 (7 str) x & PMP12/3GGHD 12/3 (19 str) 12 (19 str) x & PMP10/3GGHD 10/3 (19 str) 10 (19 str) x & PMP8/3GGHD 8/3 (19 str) 10 (19 str) x & PMP6/3GGHD 6/3 (19 str) 8 (19 str) x & PMP4/3GGHD 4/3 (19 str) 8 (19 str) x & PMP2/3GGHD 2/3 (19 str) 6 (19 str) x & PMP1/03GGHD 1/03 (19 str) 6 (7 str) x Bulk PMP2/03GGHD 2/03 (19 str) 6 (7 str) x Bulk PMP3/03GGHD 3/03 (19 str) 4 (7 str) x Bulk PMP4/03GGHD 4/03 (19 str) 4 (7 str) x Bulk PMP250/3GGHD 250/3 (37 str) 4 (7 str) x Bulk PMP350/3GGHD 350/3 (37 str) 3 (7 str) x Bulk Pump and Irrigation Per Table of the NEC All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. * Direct Burial rated in sizes 12 through 4/0 AWG, upon request All sales are subject to Standard Terms & Conditions of Sale Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA

63

64

65

66

67

68

69

70

71

72

73

74

75

76

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable

More information

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE PRODUCTS COMMERCIAL BUILDING WIRE & CABLE Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored

More information

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)... MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper THHN/THWN-2/MTW/T90 PVC Insulation with Nylon Jacket Solid or Stranded Soft-annealed Uncoated Copper Specifications ASTM (American Society for Testing & Material ASTM B3 Class B, B8 (sizes 6 and larger),

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

IEEE 1580 TYPE T/N CABLE

IEEE 1580 TYPE T/N CABLE 1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

TUNNELING POWER CABLES

TUNNELING POWER CABLES TUNNELING POWER CABLES Index 3- Type G-GC (Round) 3/C kv..................... -3 3-5 Type SHD-GC 3/C 5kV........................ -5 3-55 Type SHD-GC 3/C 5kV........................ - 3-0/0/0 Type MP-GC

More information

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 UF103WG250 10/3 WG Uf Cable-250' Southwire Company Catalog Number Manufacturer Description Weight per unit Product Category

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable SERVING THE NUCLEAR POWER MARKETS power generating plants original equipment manufacturer storage and waste management facilities

More information

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight. 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category MC122IG 12/2

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SEU43500 4-4-4 Seu Cable-500' Southwire Company Catalog Number SEU43500 Manufacturer Southwire Company Description Copper

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 310 310.120 CHANGES FROM 2011 TO 2014 CODE ARE IN RED ARTICLE 310 Conductors for General Wiring I. General 310.2 Definitions Electrical Ducts Electrical conduits, or other

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum

More information

Automotive Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers

More information

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE EXPERIENCED. RELIABLE. TRUSTED. QUALITY. WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE KalaS headquarters KalaS los angeles 28365 Constellation Road, Unit B KalaSwIRe.COM P 717.336.5575 RELIABLE DEPENDABLE

More information

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding

More information

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES 37- TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 000 VOLTS FEATURES Highly durable, abrasion-resistant CPE jacket specially designed

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

KALAS ENTERTAINMENT CABLE

KALAS ENTERTAINMENT CABLE KALAS ENTERTAINMENT CABLE DELIVERING DEPENDABILITY FOR MORE THAN HALF A CENTURY Kalas is a full-service manufacturer with over 55 years of experience. We are strategically positioned to deliver quality

More information

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION Armorlite Type MC Lightweight Aluminum Interlocked Armor. 600 Volts. Copper Power Conductors. THHN/THWN Insulated Singles. Green Insulated Grounding Conductor. Sizes 14 AWG through 2 AWG. Rated VW-1. APPLICATIONS

More information

Mecklenburg County Common Code Defects

Mecklenburg County Common Code Defects Electrical Code Defects Improper Over Current Protection Code Description 310.15 Ampacities for s Rated 0 2000 Volts. (A) General. (1) Tables or Engineering Supervision. Ampacities for conductors shall

More information

Okoguard -Okoseal Type IEC

Okoguard -Okoseal Type IEC COMPACT STRAND CONSTRUCTION A B C D E F G H Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded Semiconducting EPR Phase

More information

Primary, Secondary, Post-Secondary Education Facilities

Primary, Secondary, Post-Secondary Education Facilities STABILOY Feeder Solutions Primary, Secondary, Post-Secondary Education Facilities Introduction At Alcan Cable your children s safety is our top concern. That is why our STABILOY aluminum alloy feeder cables

More information

HOSPITAL AND HEALTHCARE

HOSPITAL AND HEALTHCARE STABILOY Brand Feeder Solutions HOSPITAL AND HEALTHCARE Introduction General Cable understands that hospitals require complex buiding designs that must address a wide range of systems and applications.

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

INDUSTRIAL

INDUSTRIAL WWW.GENERGYCABLE.COM 8003081330 TM INDUSTRIAL INDUSTRIAL CATALOG Flexible. GenErgy was born from a wire and cable manufacturer with over a half a century of experience. The result is the most comprehensive

More information

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES Introduction When it comes to feeder cables, General Cable keeps industries of all types humming with cost savings on total installation,

More information

ATHLETIC STADIUMS AND SPORTS ARENAS

ATHLETIC STADIUMS AND SPORTS ARENAS STABILOY Brand Feeder Solutions ATHLETIC STADIUMS AND SPORTS ARENAS Introduction Stadiums of all shapes and sizes require a consistent source of power to keep their fans happy. At General Cable, dependability

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology ANACONDA SEALTITE 2018 ANAMET Electrical, Inc. AN ANAMET COMPANY When you say SEALTITE, there is only one: ANACONDA. Type MTC Type

More information

Electrical Design/Build Guide

Electrical Design/Build Guide 2017 Electrical Design/Build Guide Based on the 2017 National Electrical Code Copyright Durand & Associates 1986-2016 60 C Copper Ampacity 4 - Wire Fill - (Non-Current Carrying Neutral) 4 or 5 - Parallel

More information

E R C. R E R C ; ; W T E C

E R C. R E R C ; ; W T E C WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation

More information

The Reliable Choice. Field Pocket Guide

The Reliable Choice. Field Pocket Guide The Reliable Choice Field Pocket Guide Allowable Ampacities of STABILOY Brand XHHW-2 and Copper 75 C (167 F) 90 C (194 F) 75 C (167 F) 90 C (194 F) Conductor Size (AWG or kcmil) Types RHW, THHW, THW, THWN,

More information

PART A General Conductor Requirements

PART A General Conductor Requirements PART A General Conductor Requirements 6.1 Conductor Insulation Property Table 310.13 of the NEC provides information on conductor properties such as permitted use, maximum operating temperature, and other

More information

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER BRONCO Brand TM Premium Flexible Power Cable PHILATRON WIRE AND CABLE * USA MANUFACTURER WWW.PHILATRON.COM Table of Contents BRONCO-15 Cable & Cord Description To: Bronco-15 From: Bronco-66 History: To

More information

SHIELD-FLEX EMI / RFI Shielded Conduit

SHIELD-FLEX EMI / RFI Shielded Conduit Type SLA SHIELD-FLEX EMI / RFI Shielded Conduit Type EMS Type EMCS z Wire without interference. Shielded conduit provides exceptional shielding effectiveness from electromagnetic and radio frequency interference

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

Hook-Up Wire Alpha Wire ALPHA 373

Hook-Up Wire Alpha Wire ALPHA 373 Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 373 The broad range of hookup wire from Alpha means you will find the product exactly suited to

More information

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE CABLE SOLUTIONS to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE GENERAL CABLE DELIVERS Advanced Reliability, Safety And Sustainability To The Nuclear Power Industry Safe,

More information

Medium Voltage Power Cables

Medium Voltage Power Cables Medium Voltage Power s Distribution s (CN s) are suitable for use above ground in open air, in conduit in air, directly buried, in underground duct, or aerially when suspended on a messenger wire. CN cables

More information

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).

More information

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Medium Voltage Cables for PermaLife Nuclear Utility Applications Medium Voltage Cables for PermaLife Nuclear Utility Applications The science behind our medium voltage cables. Fig. 1 Fig. 2 non-conducting stress control layer 100% production tested in accordance with

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Electronic Instrumentation

Electronic Instrumentation Applications Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and

More information

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power

More information

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked. ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES Black Crosslinked High-Density Polyethylene (XLHDPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C 10 SOOW 90 C./;SOOW 90 C/11709 Index1.W&C Energy Products////600v Thermoset Jkt'd SOOW 90 C PR33307V2-240057.eps Synthetic rubber insulation Thermoset jacket 90 C, 600 V 1. CONDUCTOR: Bare, annealed copper

More information

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS JANUARY 2015 The Low Friction Advantage in Cable Installation General Cable s new High Speed industrial cable, with Xtra Low Friction

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

Category # 1 - Overhead, Primary, & Secondary Conductors

Category # 1 - Overhead, Primary, & Secondary Conductors City of Alexandria Bid Proposal # 2214 Open Date - November 27, 2018 Page BF1of BF7 Category # 1 - Overhead, Primary, & Secondary Conductors 1. 2801602110 17,100 LB. CABLE, 477 MCM AAC CONDUCTOR, $ - $

More information

INFORMATION. Hybrid cables. Description

INFORMATION. Hybrid cables. Description Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, Flamarrest insulation and jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color

More information

SHIELD-FLEX EMI / RFI Shielded Conduit

SHIELD-FLEX EMI / RFI Shielded Conduit Type SLA SHIELD-FLEX EMI / RFI Shielded Conduit Type EMS EMCS Type z Wire without interference. Shielded conduit provides exceptional shielding effectiveness from electromagnetic and radio frequency interference

More information

VITALink Taped Splice Pigtail Crimp

VITALink Taped Splice Pigtail Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice

More information

Delivering Dependability for More Than a Half Century

Delivering Dependability for More Than a Half Century Delivering Dependability for More Than a Half Century Kalas is a full-service manufacturer with 60 years of experience. We are strategically positioned to deliver quality cable and value-add solutions

More information

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary

More information

Battery Cables. Wire & Cable

Battery Cables. Wire & Cable Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable ed Primary UD TRXLP ed Primary UD TRXLP Cable Aluminum or Copper Conductor. TRXLP Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for

More information

Medium Voltage Cable. marmonutility.com

Medium Voltage Cable. marmonutility.com Medium Voltage marmonutility.com Table Contents Introduction... 2 Hendrix Product Information... 4 Distribution s (URD) 15kV...6 25kV... 10 35kV...12 28kV...14 Electrical Data...16 Kerite Product Information...

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information