Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Size: px
Start display at page:

Download "Introduction. Nexans wire and cable. Contact us for all your wire and cable needs"

Transcription

1

2 Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and produce a wide range of cables used in power, industrial, construction and communication applications. With more than a century of experience as a leader in the industrial and power cable markets, Nexans is contracted by heavy industry and utilities worldwide to provide turnkey solutions for the bulk transmission of power - from generating station through the transmission and distribution systems to commercial, residential and industrial areas. This catalog has been prepared for the convenience of those using electrical conductors in industrial, commercial and residential applications. The information included in the many tabulations will be of particular value to the architect, engineer, electrician, and layperson alike. For your convenience, we have referenced applicable Articles and Tables from both the 2008 NEC and the 2011 NEC. Although we have listed the types of wires and cables suitable for most conditions, we are equipped to manufacture other types to suit special needs. We would be pleased to recommend the most suitable construction for any special condition that you may encounter. The determination of the correct cable size and type, and the selection of methods of installation suitable for the type and location of particular circuits, should be made in accordance with local regulations. Any questions in this respect should be directed primarily to the local Electrical Inspection Authority. We are pleased to note that all the cables in this catalog are LEAD FREE. This indicates that the component has less than 300 ppm of lead, which is well below the 1000 ppm level indicated in RoHS (restriction of hazardous substances) regulations and below the level requiring labeling by California Proposition #65. Nexans wire and cable Contact us for all your wire and cable needs Nexans Energy USA inc. 25 Oakland Avenue Chester, NY Tel: A t t h e c o r e o f p e r f o r m a n c e 1

3 ENERGEX Building Wire INTRODUCTION...Page 1 TABLE OF CONTENTS...Page 2 ENERGEX BARE COPPER...Page 3 ENERGEX TFN/TFFN Copper... Pages 4 & 5 ENERGEX THHN/THWN-2/MTW Copper... Pages 6 & 7 ENERGEX NM-B Copper... Pages 8 & 9 ENERGEX UF-B Copper.... Pages 10 & 11 ENERGEX XHHW-2 Copper.... Pages 12 & 13 ENERGEX 8000 XHHW-2 Aluminum... Pages 14 & 15 ENERGEX RHH/RHW-2/USE-2 Copper... Pages 16 & 17 ENERGEX 8000 RHH/RHW-2/USE-2 Aluminum... Pages 18 & 19 ENERGEX 8000 Mobile Home Feeder Aluminum... Pages 20 & 21 ENERGEX PV 600 Volt Copper... Pages 22 & 23 ENERGEX 8000 PV 600 Volt Aluminum... Pages 24 & 25 ENERGEX PV 2 kv Copper... Pages 26 & 27 ENERGEX 8000 PV 2 kv Aluminum... Pages 28 & 29 ENERGEX MC 120 Volt Copper.... Pages 30 & 31 ENERGEX MC 277 Volt Copper.... Pages 32 & 33 ENERGEX 8000 SER Aluminum... Pages 34 & 35 ENERGEX 8000 SEU Aluminum... Pages 36 & 37 ENERGEX URD Aluminum... Pages 38 & 39 WARRANTY & NOTES... Pages 40 2

4 Description Solid or stranded 100% conductivity copper conductors. ASTM B3 Soft or Annealed Copper Wire* ASTM B8 Concentric - Lay - Stranded Copper Conductors Application Used for bonding and grounding electrical circuits and systems. Soft Drawn Bare Copper UL Solid - ASTM B3 Stranded - ASTM B8 Conductor Number of Nominal Approximate Net Average D.C. Size Strands Diameter Cable Weight Resistance at 25 C AWG/kcmil inches mm lbs/kft kg/km Ω/kft Ω/km / / / / Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. *ASTM B3 Specification details the requirements for solid wires and the individual wires in stranded conductors. 3

5 ENERGEX TFN/TFFN PVC Insulated Cable 600 Volts, 90 C - Lead Free Copper Conductors Applications Nexans ENERGEX TFN (solid) /TFFN (flexible stranded) copper conductors may be used as fixture wire, machine tool wire (MTW) or for appliance wiring material (AWM), as outlined in the NEC 2008 and NEC These conductors are heat, moisture, and gasoline and oil resistant II. TFN and TFFN are used for internal wiring of lighting fixtures and similar equipment, and for connection to branch circuit wiring inside lighting fixtures and similar equipment. TFN/TFFN is rated at a conductor temperature of 90 C in dry locations. MTW is used for internal wiring of machines tools, rated 90 C in dry locations and 60 C when exposed to oils or coolants. AWM is used as factory installed internal wiring of appliances, rated 105 C in dry locations. Nexans TFN/TFFN conductors are Lead Free and RoHS compliant. Construction Conductor: TFN - solid annealed soft bare copper per ASTM B3. TFFN/MTW/AWM - flexible stranded annealed soft bare copper per ASTM B174 Insulation: Color coded, heat, moisture and flame resistant polyvinyl chloride (PVC). Covering: Strong, slick polyamide (Nylon) outer covering, Colors: Standard TFN and TFFN colors available in black, white, red, blue, green, yellow, pink, purple, orange, brown and gray. Additional colors are made per request subject to factory minimum order quantities. Surface Print Legend: NEXANS-F 16 AWG (1.31 mm2) (UL) TFFN or MTW or AWM 600V VW-1 GASOLINE AND OIL RESISTANT II LEAD FREE MADE IN CANADA (MFG. DATE) Specifications Nexans ENERGEX TFN/TFFN meets or exceeds UL 66 (Fixture Wires) and the requirements of the National Electrical Code - Fixture wire. TFFN meets or exceeds UL 1063 (Machine-Tool Wires and Cables) for Machine Tool Wire and UL 758 (Appliance Wiring Materials) for AWM Style The insulation is heat, moisture, gasoline and oil resistant II. TFN/TFFN shall be lead free and RoHS compliant. Voltage rating Volts. Product Features Heat and moisture resistant Gasoline and oil resistant II Rated for use as appliance wiring Available from inventory in 11 colors Lead Free and RoHS compliant 4

6 PVC Insulated Cable 600 Volts, 90 C - Lead Free Copper Conductors ENERGEX TFN/TFFN UL 66 UL 1063 UL 758, Style 1316 Conductor PVC Insulation Nylon Nominal Approximate Net Ampacity Size Thickness Thickness Diameter Cable Weight (Amps) AWG mils mm mils mm inches mm lbs/kft kg/km TFN/TFFN MTW 90 C TFN 18 (1) (1) TFFN / MTW 18 (16) (26) Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article , and Table Allowable Ampacity for Fixture Wires at an ambient temperature of 30 C (with no load diversity). For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B) (16). Refer to NEC 2008 and NEC 2011 Article 240.4(D) for overcurrent protection requirements. 1 Allowable ampacities for MTW are as shown in NFPA 79. 5

7 ENERGEX THHN/ THWN-2/MTW PVC/Nylon Cable 600 Volts, 90 C - Lead Free Copper Conductors Applications Nexans ENERGEX THHN/THWN-2/ MTW* is a general purpose wiring product for use in power, lighting and control circuits. It can be used in conduit, ducts and trays for service feeders and branch circuits in industrial and commercial installations. When used in accordance with the 2008 or 2011 NEC, THHN/THWN-2 is suitable for use in wet and dry locations, at conductor temperatures not exceeding 90 C or for use in oil or coolants at conductor temperatures not exceeding 75 C. THHN/THWN-2 is gasoline and oil resistant II. When used as Machine Tool Wire (MTW) it is rated at 90 C in dry locations and 60 C in wet locations or when exposed to oil or coolants. Nexans THHN/THWN-2/MTW wire is Lead Free and RoHS compliant. * Only stranded cables are MTW listed per UL Construction Conductor: Solid bare, annealed copper per ASTM B3. Stranded bare annealed copper per ASTM B3 and ASTM B787 for sizes 14, 12, 10 and 8 AWG and ASTM B8 for sizes 6 AWG and larger. Insulation: Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound per UL 83 and UL 1063 Covering: A tough abrasion resistant polyamide (Nylon) covering Surface Print Legend: NEXANS- C 500 kcmil (253mm2) TYPE MTW OR THHN OR THWN-2 GRII SR FOR CT USE VW-1 600V (UL) LEAD FREE (MFG. DATE) Specifications Nexans ENERGEX THHN/THWN- 2 or MTW meets or exceeds all applicable ASTM specifications UL 83: Thermoplastic Insulated Wires and Cables UL 1063: Machine-Tool Wires and Cables (stranded cables only) Nema WC70 / ICEA S : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Federal Specification A-A and requirements of the NEC CSA C22.2 No. 75: Thermoplastic Insulated Wires and Cables 14 AWG through 750 kcmil are rated VW-1 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Black sizes 1/0 AWG and larger are sunlight resistant Voltage rating volts. Product Features Sizes 8 AWG to 600 kcmil available in various colors from stock Cables are UL listed as Type THHN/ THWN-2/MTW* Meets UL VW-1 flame test requirements Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Black 1/0 AWG and larger is sunlight resistant High heat and moisture resistant THWN-2 90 C rated for dry and wet locations Gasoline and Oil Resistant II Small diameter for improved conduit fill Lead Free and RoHS compliant Packaging 14 & 12 AWG: 4 x 500 spools (2000 per carton) or 2500 reel 10 AWG: 2 x 500 spools (1000 per carton) or 2500 reel 8 AWG - 4/0 kcmil: 500, 1000, 2500 or 5000 reel 250 kcmil kcmil: 500, 1000, or 2500 reel 750 kcmil: 1000 reel 6

8 PVC/Nylon Cable 600 Volts, 90 C - Lead Free Copper Conductors ENERGEX THHN/ THWN-2/MTW UL 83 / CSA C22.2 No. 75 UL 1063 ICEA S Conductor PVC Insulation Nylon Nominal Diameter Approximate Net Ampacity* Size Thickness Thickness Cable Weight (Amps) AWG/kcmil mils mm mils mm inches mm lbs/kft kg/km 60 C 75 C 90 C 14 (1) (1) (1) (19) (19) (19) (19) (19) (19) (19) (19) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. For MTW in wet locations or when exposed to oil or coolant. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. THWN-2 when exposed to oil or coolant. 90 C - THHN dry locations. THWN-2 wet or dry locations. For ampacity derating purposes. Available colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Purple, Gray, Pink. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article , which are based on NEC 2008 Table or NEC 2011 Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B)(16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 7

9 ENERGEX NM-B PVC/Nylon Insulated Cable 600 Volts, 90 C Dry - Lead Free Copper Conductors Applications Nexans ENERGEX non-metallic sheathed cable NM-B is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90 C dry, its ampacity is limited to 60 C according to the NEC 2008 and NEC It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. Nexans NM-B cables are Lead Free and RoHS compliant. Construction Conductor: Solid 14 to 10 AWG annealed soft bare copper per ASTM B3. Stranded 8 AWG and larger annealed soft bare copper per ASTM B3 and B8. Insulation: Color coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90 C. Ground: Soft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8 Sheath: 30 mil color coded PVC sheath rated 90 C is applied over the completed assembly: White 14 AWG Yellow 12 AWG Orange 10 AWG Black 8 to 2 AWG Surface Print Legend: NEXANS-C ENERGEX 2C-14 AWG TYPE NM-B 600V W/GRD (UL) LEAD FREE MM/ DD/YY MADE IN U.S.A. Specifications Nexans ENERGEX NM-B meets or exceeds all applicable ASTM specifications. UL 83: Thermoplastic Insulated Wires and Cables UL 719: Non-Metallic Cables Federal Specification A-A and requirements of the NEC. Voltage rating volts. Product Features Slick proprietary sheathing material designed for ease of installation Color coded sheaths designed for quick cable identification Lead free and RoHS compliant 14 AWG 2C and 12 AWG 2C available with two neutral conductors Packaging 14, 12 & 10 AWG; 2, 3 and 4 conductor ft coil and 1000 ft reel 8 AWG and larger 2 and 3 conductor ft coil, 500 and 1000 ft reel 8

10 PVC/Nylon Insulated Cable 600 Volts, 90 C Dry - Lead Free Copper Conductors ENERGEX NM-B UL 83 UL 719 Conductor # of PVC Insulation Ground Nylon Nominal Cable Approximate Net Ampacity Size Conductors Thickness Wire Size Thickness Dimensions Cable Weight (Amps) AWG mils mm AWG mils mm inches mm lbs/kft kg/km Two Conductor 14 (1) (1) x x (1) (1) x x (1) (1) x x (7) (1) x x (7) (1) x x Three Conductor 14 (1) (1) (1) (1) (1) (1) (7) (1) (7) (1) (7) (7) (7) (7) Four Conductor 14 (1) 2/ (1) (1) (1) (1) 2/ (1) (1) (1) Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Articles and , which are based on NEC 2008 Table or NEC 2011 Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature and 60 C rated conductors. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article (E) through (G) 1 Insulation color code for 2 / 2 conductor cable is Black, White, Red, and White with Red stripe. Cable ampacity is based on the White and White with Red stripe conductors being connected as the neutrals for the system. 2 Insulation color code for 4 conductor cable is Black, White, Red and Blue. Cable ampacity is based on the 4th conductor being connected as the neutral conductor of a balanced 3 phase system. 9

11 ENERGEX UF-B PVC/Nylon Insulated Cable 600 Volts, 90 C Dry - Lead Free Copper Conductors Applications Nexans ENERGEX UF-B is an underground feeder and branch circuit wiring cable. Its applications are outlined in Article 340 NEC 2008 and NEC UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90 C dry / wet its ampacity is limited to 60 C according to the NEC 2008 and NEC UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 or NEC 2011 Article 334. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Nexans UF-B cables are Lead Free and RoHS compliant. Construction Conductor: Solid annealed soft bare copper per ASTM B3. Stranded annealed soft bare copper per ASTM B3 and ASTM B8. Insulation: Polyvinyl chloride (PVC) with a nylon covering. Color coded phase identification. Ground: Soft bare copper, solid per ASTM B3 and stranded per ASTM B3 and ASTM B8. Jacket: Sunlight, moisture and fungus resistant gray PVC. Surface Print Legend: NEXANS-C ENERGEX 2C-14 AWG W/GRND TYPE UF-B SUN RES 600V (UL) LEAD FREE MM/DD/YY MADE IN U.S.A. Specifications Nexans ENERGEX UF-B meets or exceeds all applicable ASTM specifications. UL 83: Thermoplastic Insulated Wires and Cables UL 493: Thermoplastic-Insulated Underground Feeder and Branch Circuit Cables Federal Specification A-A and requirements of the NEC. Voltage rating volts. Product Features Slick proprietary jacketing compound designed for quick and easy installation Gray jacket designed for quick cable identification Lead free and RoHS compliant Meets or exceeds all applicable industry standards Packaging 14, 12 & 10 AWG; 2, 3 and 4 conductor: 250 ft coil and 1000 ft reel 8 & 6 AWG; 2 and 3 conductor: 125 ft coil and 500 ft reel Bar coded reels and coils for ease of material handling 10

12 ENERGEX UF-B UL 83 UL 493 PVC/Nylon Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors Conductor PVC Insulation Nylon PVC Jacket Ground Nominal Cable Approximate Net Ampacity Size Thickness Thickness Thickness Wire Size Dimensions Cable Weight (Amps) AWG mils mm mils mm mils mm AWG inches mm lbs/kft kg/km Two Conductor With Ground 14 (1) (1) 0.18 x x (1) (1) 0.19 x x (1) (1) 0.22 x x (7) (1) 0.31 x x (7) (1) 0.34 x x Three Conductor With Ground 14 (1) (1) 0.18 x x (1) (1) 0.19 x x (1) (1) 0.22 x x (7) (1) 0.32 x x (7) (1) 0.38 x x Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Articles and , which are based on NEC 2008 Table or NEC 2011 Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature and 60 C rated conductors. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B)(16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 11

13 ENERGEX XHHW-2 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors Applications Nexans ENERGEX XHHW-2 is a copper conductor, with crosslinked polyethylene insulation. The cable is rated at 600 volts and 90 C for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC 2008 and NEC Sizes 14 to 4/0 AWG are approved as Type SIS. Sizes 1/0 AWG and larger (4 AWG and larger in green) in all colors are cable tray (CT) rated. Nexans XHHW-2 conductors are Lead Free. Construction Conductor: Annealed soft bare copper per ASTM B3, B787 and B8 Insulation: Cross-linked polyethylene (XLPE) insulation per UL 44 Surface Print Legend: NEXANS EXELENE 500 kcmil (253 mm2) XHHW- 2 (UL) E64801 F 600V FOR CT USE SR - MADE IN CANADA LEAD FREE (MFG. DATE) Specifications Nexans ENERGEX Type XHHW- 2 meets or exceeds all applicable ASTM specifications. UL 44: Thermoset-Insulated Wires and Cables Federal Specification A-A and the requirements of the NEC. NEMA WC70 / ICEA S : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use. Sunlight resistant in black 8 AWG and larger. 14 to 10 AWG are available in 10 distinct colors for identification purposes. Sizes 14 to 4/0 AWG rated SIS. Nexans XHHW-2 is lead free. Voltage rating Volts. Product Features Sizes 14, 12 and 10 AWG are available in 10 colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Gray, Purple. Size 8 AWG and larger in black only. Meets IEEE 1202 Conforms to ICEA S Sunlight Resistant 8 AWG and larger in black Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Sizes 14 to 4/0 AWG rated SIS Meets or exceeds all applicable industry standards Lead Free Packaging 14 to 10 AWG 2 x 500 spools (1000 feet) per carton; 2500 reel 8 AWG kcmil long length 750 kcmil 500 reel or long length 12

14 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX XHHW-2 UL 44 ICEA S Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 14 (7) (7) (7) (7) (7) (7) (7) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) (61) *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - Wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article , which are based on NEC 2008 Table or NEC 2011 Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 13

15 ENERGEX 8000 Type XHHW-2 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors Applications Nexans ENERGEX 8000 XHHW-2 is an AA-8000 series aluminum (ACM) conductor with cross-linked polyethylene insulation. The cable is rated at 600 volts and 90 C for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC 2008 and NEC Sizes 12 to 4/0 AWG are approved as SIS. Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use. Nexans XHHW-2 is lead free. Construction Conductor: compact stranded AA-8000 series aluminum alloy per ASTM B800 and B801 Insulation: black sunlight resistant, cross-linked polyethylene (XLPE) meeting the requirements for XHHW-2 per UL 44. Specifications Nexans ENERGEX 8000 XHHW-2 meets or exceeds all applicable ASTM specifications. UL 44: Thermoset-Insulated Wires and Cables NEC 2008 Article or NEC 2011 Article Federal Specification A-A and the requirements of the NEC. NEMA WC7O / ICEA S : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Sunlight Resistant 8 AWG and larger in black Sizes 12 to 4/0 AWG rated SIS Voltage rating Volts. Meets IEEE 1202 Product features Cables are UL listed as Type XHHW-2 Temperature rating of 90 C dry and wet Sunlight Resistant, black 8 AWG and larger Lead Free Bare conductors are heat treated after stranding for maximum flexibility Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Sizes 12 to 4/0 AWG rated SIS Surface Print Legend: NEXANS-C 1/0 AWG COMPACT AA AL XHHW-2 600V FOR CT USE SR LEAD FREE (UL) (MFG. DATE) 14

16 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 Type XHHW-2 UL 44 ICEA S Conductor Insulation Nominal Approximate Net Ampacity* Size Thickness Diameter Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 6 (7) (7) (7) (18) /0 (18) /0 (18) /0 (18) /0 (18) (35) (35) (35) (35) (35) (58) (58) (58) *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - Wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article , which are based on NEC 2008 Table or NEC 2011 Table (B)(16) for aluminum conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 15

17 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX RHH/RHW-2/USE-2 Applications Nexans ENERGEX RHH/RHW-2/ USE-2 conductors may be installed in raceways and conduits or directly buried. They are 90 C, 600 volts per NEC 2008 and NEC 2011 Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are Lead Free. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Surface Print Legend: NEXANS 1/0 AWG (53.5 mm2) (UL) E64801 F RHW-2 OR USE-2 600V FOR CT USE SR MADE IN CANADA LEAD FREE (MFG DATE). Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854: (USE-2) Service Entrance Cables Federal Specification A-A ICEA S : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy National Electrical Code - NFPA 70 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Product Features Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant Lead Free 16

18 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX RHH/RHW-2/USE-2 UL 44 UL 854 ICEA S Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 14 (1) (1) (1) (7) (7) (7) (7) (7) (7) (7) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) (61) *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article , which are based on NEC 2008 Table or NEC 2011 Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 17

19 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 RHH/RHW-2/USE-2 Applications Nexans ENERGEX RHH/RHW-2/ USE-2 conductors may be installed in raceways and conduits or directly buried. They are 90 C, 600 volts per NEC 2008 and NEC 2011 Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are Lead Free. Construction Conductor: compact stranded AA-8000 series aluminum alloy per ASTM B800 and B801 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Surface Print Legend: NEXANS-C 1/0 AWG COMPACT AA-8000-AL USE-2 OR RHH OR RHW-2 600V FOR CT USE SUN RES (UL) LEAD FREE (MFG. DATE) Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854: (USE-2) Service Entrance Cables Federal Specification A-A ICEA S : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy National Electrical Code - NFPA 70 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Product Features Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant Lead Free Bare conductors are heat treated after stranding for maximum flexibility 18

20 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 RHH/RHW-2/USE-2 UL 44 UL 854 ICEA S Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 6 (7) (7) (7) (18) /0 (18) /0 (18) /0 (18) /0 (18) (35) (35) (35) (35) (35) (58) (58) (58) (58) *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article , which are based on NEC 2008 Table or NEC 2011 Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table or NEC 2011 Table (B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 19

21 XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 Mobile Home Feeder Applications Nexans ENERGEX Mobile Home Feeder is a twisted assembly of RHH / RHW-2 / USE-2 insulated aluminum conductor material (ACM), AA-8000 series alloy conductors. The cable is used as a service cable to feed mobile homes in parks and permanent locations. ENERGEX 8000 Mobile Home Feeders are designed to be directly buried. The cable is rated at 600 volts and 90 C for use in wet and dry locations in accordance with NEC 2008 and NEC 2011 Article Nexans Mobile Home Feeder cables are Lead Free. Construction Conductor: compact stranded AA-8000 series aluminum alloy per ASTM B800 and B801 Insulation: solid color-coded sunlight resistant cross-linked polyethylene (XLPE) Assembly: black and red conductors are cabled with the white neutral conductor and green equipment grounding conductor. Surface Print Legend: NEXANS-C 4/0 AWG COMPACT AA AL USE-2 OR RHH OR RHW-2 600V SUN RES LEAD FREE (UL) (MFG. DATE) Specifications Meets UL 854: Service Entrance Cables Meets UL 44: Thermoset-Insulated Wires and Cables Product features Cables are UL listed as Service Entrance Cable Solid color insulation Temperature rating of 90 C dry and wet Sunlight Resistant Lead Free Bare conductors are heat treated after stranding for maximum flexibility 20

22 XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 Mobile Home Feeder UL 854 UL 44 Insulation Thickness Insulation Thickness Insulation Thickness Cable Approximate Net Ampacity* Cable Construction Phase Conductors Neutral Conductor Grounding Conductor Diameter Cable Weight (Ph 1 + Ph 2 + N + G) mils mm mils mm mils mm inches lb/mft kg/km Amps /0 + 4/0 + 2/ Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. * Ampacities are in accordance with NEC 2008 Table (B)(6) or NEC 2011 Table (B)(7) and are based on 90 C conductor temperatures, 20 C ambient earth temperature, earth thermal resistivity Rho=90, cables buried 36 deep, only the phase conductors carrying current and 100% load factor. 21

23 XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free Copper Conductors ENERGEX PV/RHH/RHW-2/USE-2 Applications Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Nexans ENERGEX PV/RHH/RHW-2/ USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90 C, 600 V per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Surface Print Legend: (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use UL File Numbers: E (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Product features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use LEAD FREE Options Class C stranding available 22

24 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX PV/RHH/RHW-2/USE-2 UL 44 UL 854 UL 854 subject 4703 ICEA S Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 8 (7) (7) (7) (7) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) (61) *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. PV, RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Allowable ampacities shown are for general use as specified by the NEC, Section For conductors installed in conduit on a rooftop, use the derating factors specified by Table (B)(3)(c) in the NEC. Note: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. 23

25 XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free Aluminum Conductors ENERGEX 8000 PV/RHH/RHW-2/USE-2 Applications Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Nexans ENERGEX PV/RHH/RHW-2/ USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 600 V per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Compact stranded AA series aluminum alloy (ACM) per ASTM B801 or B836 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Surface Print Legend: (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) CPT ACM ALUM (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use UL File Numbers: E (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Product features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use LEAD FREE Options Class C stranding available 24

26 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Aluminum Conductors ENERGEX 8000 PV/RHH/RHW-2/USE-2 UL 44 UL 854 UL 854 subject 4703 ICEA S Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 6 (7) (7) (6) (8) /0 (10) /0 (12) /0 (16) /0 (18) (35) (35) (35) (35) (35) (58) (58) (58) *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. PV, RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Allowable ampacities shown are for general use as specified by the NEC, Section For conductors installed in conduit on a rooftop, use the derating factors specified by Table (B)(3)(c) in the NEC. Note: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. 25

27 XLPE Insulated Cable 2 kv, 90 C Dry and Wet - Lead Free Copper Conductors ENERGEX PV/RHH/RHW-2/USE-2 Applications Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Nexans ENERGEX PV/RHH/RHW-2/ USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Surface Print Legend: (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) (UL) USE-2 600V OR RHW-2 OR PV WIRE 2000V 90C WET OR DRY SR DIR BUR LEAD FREE Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use UL File Numbers: E (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Product features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use LEAD FREE Options Class C stranding available 26

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE PRODUCTS COMMERCIAL BUILDING WIRE & CABLE Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper THHN/THWN-2/MTW/T90 PVC Insulation with Nylon Jacket Solid or Stranded Soft-annealed Uncoated Copper Specifications ASTM (American Society for Testing & Material ASTM B3 Class B, B8 (sizes 6 and larger),

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)... MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SEU43500 4-4-4 Seu Cable-500' Southwire Company Catalog Number SEU43500 Manufacturer Southwire Company Description Copper

More information

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 UF103WG250 10/3 WG Uf Cable-250' Southwire Company Catalog Number Manufacturer Description Weight per unit Product Category

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

Mecklenburg County Common Code Defects

Mecklenburg County Common Code Defects Electrical Code Defects Improper Over Current Protection Code Description 310.15 Ampacities for s Rated 0 2000 Volts. (A) General. (1) Tables or Engineering Supervision. Ampacities for conductors shall

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 310 310.120 CHANGES FROM 2011 TO 2014 CODE ARE IN RED ARTICLE 310 Conductors for General Wiring I. General 310.2 Definitions Electrical Ducts Electrical conduits, or other

More information

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

TUNNELING POWER CABLES

TUNNELING POWER CABLES TUNNELING POWER CABLES Index 3- Type G-GC (Round) 3/C kv..................... -3 3-5 Type SHD-GC 3/C 5kV........................ -5 3-55 Type SHD-GC 3/C 5kV........................ - 3-0/0/0 Type MP-GC

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

E R C. R E R C ; ; W T E C

E R C. R E R C ; ; W T E C WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation

More information

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight. 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category MC122IG 12/2

More information

The Reliable Choice. Field Pocket Guide

The Reliable Choice. Field Pocket Guide The Reliable Choice Field Pocket Guide Allowable Ampacities of STABILOY Brand XHHW-2 and Copper 75 C (167 F) 90 C (194 F) 75 C (167 F) 90 C (194 F) Conductor Size (AWG or kcmil) Types RHW, THHW, THW, THWN,

More information

KALAS ENTERTAINMENT CABLE

KALAS ENTERTAINMENT CABLE KALAS ENTERTAINMENT CABLE DELIVERING DEPENDABILITY FOR MORE THAN HALF A CENTURY Kalas is a full-service manufacturer with over 55 years of experience. We are strategically positioned to deliver quality

More information

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES 37- TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 000 VOLTS FEATURES Highly durable, abrasion-resistant CPE jacket specially designed

More information

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked. ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES Black Crosslinked High-Density Polyethylene (XLHDPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum

More information

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240

More information

PART A General Conductor Requirements

PART A General Conductor Requirements PART A General Conductor Requirements 6.1 Conductor Insulation Property Table 310.13 of the NEC provides information on conductor properties such as permitted use, maximum operating temperature, and other

More information

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable SERVING THE NUCLEAR POWER MARKETS power generating plants original equipment manufacturer storage and waste management facilities

More information

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE EXPERIENCED. RELIABLE. TRUSTED. QUALITY. WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE KalaS headquarters KalaS los angeles 28365 Constellation Road, Unit B KalaSwIRe.COM P 717.336.5575 RELIABLE DEPENDABLE

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION Armorlite Type MC Lightweight Aluminum Interlocked Armor. 600 Volts. Copper Power Conductors. THHN/THWN Insulated Singles. Green Insulated Grounding Conductor. Sizes 14 AWG through 2 AWG. Rated VW-1. APPLICATIONS

More information

ATHLETIC STADIUMS AND SPORTS ARENAS

ATHLETIC STADIUMS AND SPORTS ARENAS STABILOY Brand Feeder Solutions ATHLETIC STADIUMS AND SPORTS ARENAS Introduction Stadiums of all shapes and sizes require a consistent source of power to keep their fans happy. At General Cable, dependability

More information

Medium Voltage Cable. marmonutility.com

Medium Voltage Cable. marmonutility.com Medium Voltage marmonutility.com Table Contents Introduction... 2 Hendrix Product Information... 4 Distribution s (URD) 15kV...6 25kV... 10 35kV...12 28kV...14 Electrical Data...16 Kerite Product Information...

More information

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic

More information

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES Introduction When it comes to feeder cables, General Cable keeps industries of all types humming with cost savings on total installation,

More information

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme. EcoSystem Cable 369385c 1 01.22.2018 Custom designed cable, for use with EcoSystem components, improves system performance and decreases installation time. Cable is available for sensor connections and

More information

RENEWABLE ENERGY. Alcan cable solutions

RENEWABLE ENERGY. Alcan cable solutions RENEWABLE ENERGY Alcan cable solutions Renewable Energy Broch_mech5.indd 1 5/23/11 11:02:2 AM Alcan Cable s Commitment: Cabling Solutions for Wind and Solar Farms As the demand for electrical power continues

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

Hook-Up Wire Alpha Wire ALPHA 373

Hook-Up Wire Alpha Wire ALPHA 373 Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 373 The broad range of hookup wire from Alpha means you will find the product exactly suited to

More information

Medium Voltage Power Cables

Medium Voltage Power Cables Medium Voltage Power s Distribution s (CN s) are suitable for use above ground in open air, in conduit in air, directly buried, in underground duct, or aerially when suspended on a messenger wire. CN cables

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

SECONDARY 600 VOLT CABLES

SECONDARY 600 VOLT CABLES ALUMINUM UNDERGROUND SECONDARY 600 VOLT CABLES Black Crosslinked Polyethylene (XLPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum Underground Secondary 600 Volt Cables:

More information

IEEE 1580 TYPE T/N CABLE

IEEE 1580 TYPE T/N CABLE 1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

Battery Cables. Wire & Cable

Battery Cables. Wire & Cable Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,

More information

Electrical Design/Build Guide

Electrical Design/Build Guide 2017 Electrical Design/Build Guide Based on the 2017 National Electrical Code Copyright Durand & Associates 1986-2016 60 C Copper Ampacity 4 - Wire Fill - (Non-Current Carrying Neutral) 4 or 5 - Parallel

More information

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding

More information

Primary, Secondary, Post-Secondary Education Facilities

Primary, Secondary, Post-Secondary Education Facilities STABILOY Feeder Solutions Primary, Secondary, Post-Secondary Education Facilities Introduction At Alcan Cable your children s safety is our top concern. That is why our STABILOY aluminum alloy feeder cables

More information

Automotive Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers

More information

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

HOSPITAL AND HEALTHCARE

HOSPITAL AND HEALTHCARE STABILOY Brand Feeder Solutions HOSPITAL AND HEALTHCARE Introduction General Cable understands that hospitals require complex buiding designs that must address a wide range of systems and applications.

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable ed Primary UD TRXLP ed Primary UD TRXLP Cable Aluminum or Copper Conductor. TRXLP Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary

More information

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE CABLE SOLUTIONS to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE GENERAL CABLE DELIVERS Advanced Reliability, Safety And Sustainability To The Nuclear Power Industry Safe,

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

2016 Photovoltaic Solar System Plan Review List

2016 Photovoltaic Solar System Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE

More information

PHOTOVOLTAIC SYSTEMS

PHOTOVOLTAIC SYSTEMS PV WORKSHEET STANDARD STRING ARRAY Solar photovoltaic (PV) systems have widely gained acceptance as an alternative energy source. Installations range from small arrays supplying bus stop luminaires to

More information

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR DIVISION 16 - ELECTRICAL SECTION 16xx0 16xx0-1. GENERAL MANUFACTURED WIRING SYSTEM ACCESS FLOOR The modular convenience power system ensures the electrification and delivery of power from the power panels

More information

Photovoltaic Solar Plan Review

Photovoltaic Solar Plan Review PAIGE B. VAUGHAN, CBO Director of Building and Safety Phone (310) 605-5509 Fax Line (310) 605-5598 E-mail:lbutler@comptoncity.org Building & Safety Department Photovoltaic Solar Plan Review Plan Check

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

Category # 1 - Overhead, Primary, & Secondary Conductors

Category # 1 - Overhead, Primary, & Secondary Conductors City of Alexandria Bid Proposal # 2214 Open Date - November 27, 2018 Page BF1of BF7 Category # 1 - Overhead, Primary, & Secondary Conductors 1. 2801602110 17,100 LB. CABLE, 477 MCM AAC CONDUCTOR, $ - $

More information

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications Step One Preparing the Cable Strip the insulation carefully to avoid nicking or cutting conductors

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

Code Calculations. for an Off-Grid PV System

Code Calculations. for an Off-Grid PV System Code Calculations for an Off-Grid PV System John Wiles Sponsored by the Photovoltaic Systems Assistance Center, Sandia National Laboratories Judy LaPointe s home is on its way to becoming a finished, off-grid

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global

More information

FLEX-O-POWER FLEXIBLE WELDING

FLEX-O-POWER FLEXIBLE WELDING EQUIPMENT cables FLEX-O-POWER FLEXIBLE WELDING & POWER CABLE High conductivity bunched flexible annealed copper conductors, insulated with a soft flexible grade PVC suitable for welding and power purposes.

More information

Hook-Up Wire Cables you trust. Service you deserve.

Hook-Up Wire Cables you trust. Service you deserve. Hook-Up Wire Everything You Need to Hook Up Anything The broad range of hook-up wire from Alpha Wire means you will find the wire exactly suited to your application whether it s as straightforward as a

More information

DISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual

DISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual POWER PROTECTION Series 600 UPS Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz Installation Manual TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.............................................1 1.0

More information

Data sheet chainflex CFSOFT1

Data sheet chainflex CFSOFT1 to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings Your City logo here Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings PV TOOLKIT DOCUMENT #3 Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards

More information

Wired for Power Generation

Wired for Power Generation Instrumentation Cables Power Cables Control Cables Communications Cables Specialty Cables Wired for Power Generation Serving the Power Generation Market Wired for Power Generation Coax Low-Voltage Power

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical

More information

High Reliability Power System Design

High Reliability Power System Design High Reliability Power System Design Buenos Aires, Argentina June 25 & 26, 2009 Keene M. Matsuda, P.E. Regional Electrical Manager Senior Member IEEE IEEE/PES Distinguished Lecturer ke.matsuda@ieee.org

More information