1 PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

2 Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored PVC Jacketed 12 ENERGEX MC 120 Aluminum Armored Unjacketed 16 ENERGEX MC 120 Steel Armored 20 ENERGEX MC 277 Aluminum Armored 24 ENERGEX MC Aluminum Feeder Cable 28 ENERGEX MC Ground Plus 33 ENERGEX MC Mega Neutral 37 ENERGEX MC Multi Conductor 42 Direct Buried 47 ENERGEX 8000 RHH/RHW-2/USE-2 Aluminum 48 ENERGEX RHH/RHW-2/USE-2 Copper 52 Conduit Wire & Cable 56 ENERGEX 8000 Aluminum XHHW-2 57 ENERGEX INSTAGLIDE THHN / THWN-2 / MTW 61 ENERGEX INSTAGLIDE XHHW-2 Copper 65 Components, Specialty & Bare Copper 69 ENERGEX PV/RHH/RHW-2/USE-2 70 Soft Bare Copper USA* 85 Generated 8/2/18 Page 2 / 87

3 About Nexans Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance for our customers worldwide. Nexans teams are committed to a partnership approach that supports customers in four main business areas: Power transmission and distribution (submarine and land), Energy resources (Oil & Gas, Mining and Renewables), Transportation (Road, Rail, Air, Sea) and Building (Commercial, Residential and Data Centers). Nexans strategy is founded on continuous innovation in products, solutions and services, employee development, customer training and the introduction of safe, low-environmental-impact industrial processes. In 2013, Nexans became the first cable player to create a Foundation to introduce sustained initiatives for access to energy for disadvantaged communities worldwide. We have an industrial presence in 40 countries and commercial activities worldwide, employing close to 26,000 people and generating sales in 2015 of 6.2 billion euros. Nexans is listed on Euronext Paris, compartment A. Generated 8/2/18 Page 3 / 87

4 Commercial Building Wire & Cable Nexans wide assortment of safe, reliable and environmentally friendly commercial building cables assure ease of installation and provide for the safety and efficiency of low and high-rise offices, retail establishments and public buildings such as schools, hospitals and libraries. Choose the cable type required: Generated 8/2/18 Page 4 / 87

5 Armored Cables with interlocked metal tape armor or continuous metal sheath are suitable for applications where cable might be exposed to mechanical damage.the Nexans array of armored cables encompasses superior designs with rugged jackets for direct buried applications while our jacketed and unjacketed cables are manufactured for extreme conditions to withstand the dangers of physical and environmental damage that could be a factor when employed in exposed runs. Generated 8/2/18 Page 5 / 87

6 ENERGEX AC HCF Green Striped Armor Green Striped Aluminum Armored AC Cable for Health Care Facility, UL Type AC THH, 600 V, 90 C dry rated - Copper Conductors - RoHS compliant STANDARDS National UL 4; UL 83 DESCRIPTION ENERGEX AC-HCF cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They may be used in patient areas of hospitals, out-patient centers and medical and dental offices. They are not permitted where hazardous anesthetizing is performed. They may also be used in applications which require AC cable with a redundant ground in accordance with NEC Article (8). They are suitable for installations in accordance with NEC Article 320. These cables may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans AC HCF cable is RoHS compliant. Construction Conductor: Solid conductors are soft bare annealed copper to ASTM B3. Stranded conductors are soft bare annealed copper to ASTM B3 and ASTM B8. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Bond Wire: Longitudinal aluminum bond wire in continuous contact with armor. Ground Wire: Green PVC/Nylon Type THHN insulation, sized in accordance with NEC and UL. Assembly: Conductors are individually paper wrapped and cabled with a marker tape/core protection tape combination which assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Armor has an intermittent green stripe to identify HCF cable. Marker Tape Print: ALUMINUM ARMORED CABLE NOT FOR USE ON DC CIRCUITS / CAUTION NOT TO BE USED WITH SET SCREW CONNECTOR / FOR CT USE LEAD FREE (MFG DATE) Specifications Meets UL 4: Armored Cable Meets UL 83: Thermoplastic-Insulated Wires and Cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Designated Type AC per NEC Article 320 Meets UL 2556: Wire and Cable Test Methods Meets NEC Articles: , (8), (C), 320, and 645 Version V4.0 Generated 8/2/18 Page 6 / 87

7 ENERGEX AC HCF Green Striped Armor CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C ENERGEX AC HCF GREEN STRIPED ARMOR Part Number 250 ft coil1000 ft reel Number of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Diameter Approximate Net over Armor Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC75ºC90ºC (1) 12 (1) white/black (1) 12 (1) white/black/red (1) 12 (1) white/black/red/blue ¹ 20¹ 20¹ (1) 10 (1) white/black (1) 10 (1) white/black/red (1) 10 (1) white/black/red/blue ¹ 30¹ 30¹ Bend Radius: 7 overall diameter 2 12 (19) 12 (19) white/black (19) 12 (19) white/black/red Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AWG throu gh 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AW G. 90 C - Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings se e NEC Table (B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temprature and num ber of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹ Where the 4th (white) conductor is the neutral of a balanced 3 phase system. SELLING INFORMATION Product Features Version V4.0 Generated 8/2/18 Page 7 / 87

8 ENERGEX AC HCF Green Striped Armor Cables are UL listed as Type AC, 600 V UL listed insulated conductors UL listed for use in cable trays per NEC Article (2) Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor with intermittent green stripe to identify HCF cable Standard Nexans ENERGEX AC-HCF is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts Version V4.0 Generated 8/2/18 Page 8 / 87

9 ENERGEX AC Aluminum Armored AC Cable UL Type ACTHH, 600 V, 90 C dry rated - Copper Conductors - RoHS compliant STANDARDS National UL 4; UL 83 DESCRIPTION Applications ENERGEX AC cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installations in accordance to NEC Article 320. These cables may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans ACTHH cable is RoHS compliant. Construction Conductor: Solid conductors are soft bare annealed copper to ASTM B3. Stranded conductors are soft bare annealed copper to ASTM B3 and ASTM B8. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Bond Wire: Longitudinal aluminum bond wire in continuous contact with armor. Assembly: Conductors are individually paper wrapped and cabled with a marker tape/core protection tape combination which assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: ALUMINUM ARMORED CABLE NOT FOR USE ON DC CIRCUITS / CAUTION NOT TO BE USED WITH SET SCREW CONNECTOR / FOR CT USE LEAD FREE (MFG DATE) Specifications: Meets UL 4: Armored Cable Meets UL 83: Thermoplastic-Insulated Wires and Cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type AC per NEC Article 320 Version 4.0 Generated 8/2/18 Page 9 / 87

10 ENERGEX AC CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C ENERGEX AC Number of Conductors Conductor Size AWG Circuit Conductor Color Code Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC 2 14 (1) white/black (1) white/black/red (1) white/black (1) white/black/red (1) white/black/red/blue ¹ 20¹ 20¹ 2 10 (1) white/black (1) white/black/red (1) white/black/red/blue ¹ 30¹ 30¹ 3 8 (19) white/black/red (19) white/black/red Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temprature a nd number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹ Where the 4th (white) conductor is the neutral of a balanced 3 phase system. SELLING INFORMATION Product Features Version 4.0 Generated 8/2/18 Page 10 / 87

11 ENERGEX AC Cables are UL listed as Type ACTHH, 600 V UL listed insulated conductors UL listed for use in cable trays per NEC Article (2) Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Standard Nexans ENERGEX AC is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts Version 4.0 Generated 8/2/18 Page 11 / 87

12 ENERGEX MC 120 Aluminum Armored PVC Jacketed Aluminum Armored Jacketed MC Cable UL Type MC, 600 V, 90 C DRY - RoHS Compliant Copper Conductors STANDARDS National UL 1569; UL 83; UL 44 DESCRIPTION Applications ENERGEX MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction in accordance with NEC Article 330. They are suitable for installation In motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles , (C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans MC 120 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 8 AWG to 2 AWG. Insulation: Colored PVC/Nylon type THHN in accordance with UL 83, flame retardant, meeting UL VW-1 flame test for sizes 14 AWG to 1 AWG. Colored cross-linked polyethylene type XHHW-2 per UL 44 for sizes 1/0 AWG and larger. Ground Wire: Green PVC/Nylon Type THHN insulation for phase conductor sizes from 14 AWG to 1 AWG, sized in accordance with NEC and UL, (green cross-linked polyethylene Type XHHW-2 for phase conductors sized 1/0 AWG and larger). Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Jacket: Black PVC jacket. Marker Tape Print: NEXANS TYPE MC 600 VOLT FOR CT USE (SIZE) THHN (UL) E LEAD FREE (MFG DATE) Version 4.0 Generated 8/2/18 Page 12 / 87

13 ENERGEX MC 120 Aluminum Armored PVC Jacketed Specifications Meets UL 44: Thermoset Insulated Wires and Cables (1/0 AWG and larger) Meets UL 83: Thermoplastic Insulated Wires and Cables (14 AWG to 1 AWG) Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 Page 13 / 87

14 ENERGEX MC 120 Aluminum Armored PVC Jacketed ENERGEX MC 120 ALUMINUM ARMORED JACKETED Numbe r of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Diamete r over Armor Nominal Diamete r over Jacket Approximate Net Cable Weight Ampacity (Amps) inches mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 2 14 (1) 14 (1) white/black (1) 14 (1) white/black/red (1) 12 (1) white/black (1) 12 (1) white/black/red (1) 12 (1) white/black/red/blue ¹ 20¹ 20¹ 2 10 (1) 10 (1) white/black (1) 10 (1) white/black/red (1) 10 (1) white/black/red/blue ¹ 30¹ 30¹ 2 8 (19) 10 (1) white/black (19) 10 (1) white/black/red (19) 10 (1) white/black/red/blue ¹ 50¹ 55¹ 2 6 (19) 8 (19) white/black (19) 8 (19) white/black/red (19) 8 (19) white/black/red/blue ¹ 65¹ 75¹ 3 4 (19) 8 (19) white/black/red (19) 8 (19) white/black/red/blue ¹ 85¹ 95¹ 3 2 (19) 6 (19) white/black/red (19) 6 (19) white/black/red/blue ¹ 115¹ 130¹ Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambiant temperatures. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹Where the Ampacity assuming 4th (white) conductor is the neutral of a balanced 3 phase system. Version 4.0 Generated 8/2/18 Page 14 / 87

15 ENERGEX MC 120 Aluminum Armored PVC Jacketed SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article (A)(6) UL listed for use in cable trays per NEC Article (B)(1), Class II, Div.2 per NEC Article (B)(1) and Class III, Div. 1 & 2 per NEC Article (A) and with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical & physical properties Lightweight aluminum armor Nexans ENERGEX MC 120 is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation on sizes 14 AWG to 1 AWG Conductor sizes larger than 1/0 AWG Version 4.0 Generated 8/2/18 Page 15 / 87

16 ENERGEX MC 120 Aluminum Armored Unjacketed Aluminum Armored, Unjacketed MC Cable, UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction in accordance with NEC Article 330. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles , (C), 330, 396, 518, 520, 530 and 645.These cables may be installed in approved raceways and as open runs of cable on a messenger.they may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans MC 120 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 12 AWG to 2 AWG. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class B Unilay compressed stranded for sizes 1 AWG and larger. Insulation: Colored PVC/Nylon Type THHN in accordance with UL 83, flame retardant, meeting UL VW-1 flame test. Ground Wire: Green PVC/Nylon Type THHN insulation bare copper, sized in accordance with NEC and UL. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 Page 16 / 87

17 ENERGEX MC 120 Aluminum Armored Unjacketed CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 Page 17 / 87

18 ENERGEX MC 120 Aluminum Armored Unjacketed ENERGEX MC 120 ALUMINUM ARMORED UNJACKETED Nominal Diamete Part Number r Approximate Net Ampacity ConductorGround over Armor Cable Weight (Amps) Number of Size Size Circuit Conductor 250 ft coil1000 ft reelconductors AWG AWG Color Code inches mm lb/kft kg/km 60 C75 C90 C (1) 14 (1) white/black (1) 14 (1) white/black/red (1) 14 (1) white/black/red/blue ¹ 15¹ 15¹ (1) 12 (1) white/black (1) 12 (1) white/black/red (1) 12 (1) white/black/red/blue ¹ 20¹ 20¹ (1) 10 (1) white/black (1) 10 (1) white/black/red (1) 10 (1) white/black/red/blue ¹ 30¹ 30¹ (19) 12 (19) white/black (19) 12 (19) white/black/red (19) 12 (19)white/black/red/blue ¹ 20¹ 20¹ (19) 10 (19) white/black (19) 10 (19) white/black/red (19) 10 (19)white/black/red/blue ¹ 30¹ 30¹ 200 ft reel 500 ft reel (19) 8 (19) white/black (19) 8 (19) white/black/red (19) 10 (19)white/black/red/blue ¹ 50¹ 55¹ 125 ft reel 500 ft reel (19) 8 (19) white/black (19) 8 (19) white/black/red (19) 8 (19) white/black/red/blue ¹ 65¹ 75¹ (19) 8 (19) white/black/red (19) 8 (19) white/black/red/blue ¹ 85¹ 95¹ (19) 6 (19) white/black/red (19) 6 (19) white/black/red/blue ¹ 100¹ 110¹ (19) 6 (19) white/black/red (19) 6 (19) white/black/red/blue ¹ 115¹ 130¹ (19) 6 (19) white/black/red /0 (19) 6 (19) white/black/red Bend Radius: 7 x overall diameter *60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor larger than 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. Version Notes: V4.0 Generated 8/2/18 Page 18 / 87 Where stated, nominal and approximate value are provided for information purposes only and are subje ct to standard manufacturing tolerances. Ampacities are in accordance with NEC Articles and , which are based on NEC Table (B) (16) for conductors in a raceway or direct buried at 30

19 ENERGEX MC 120 Aluminum Armored Unjacketed SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article (A)(6) or NEC Article (6) For use in Class 1, Div. 2 per NEC Article (B)(1), Class II, Div.2 per NEC Article (B)(1) and Class III, Div. 1 & 2 per NEC Article with approved termination fittings. Temperature rating of 90ºC dry Suitable for direct burial Excellent mechanical & physical properties Lightweight aluminum armor Nexans ENERGEX MC 120 is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation Version V4.0 Generated 8/2/18 Page 19 / 87

20 ENERGEX MC 120 Steel Armored Steel Armored MC Cable, UL Type MC, 600 V, 90 C dry rated - RoHS Compliant, Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles , (C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans MC 120 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 12 AWG to 6 AWG. Insulation: PVC/Nylon Type THHN in accordance with UL 83, flame retardant meeting UL VW-1 flame test. Ground Wire: Green PVC/Nylon Type THHN insulation sized in accordance with NEC and UL. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking galvanized steel tape armor applied directly over the core. Marker Tape Print NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Meets UL 2256: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 Page 20 / 87

21 ENERGEX MC 120 Steel Armored CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 Page 21 / 87

22 ENERGEX MC 120 Steel Armored ENERGEX MC 120 STEEL ARMORED CABLE Part number 250 ft coil 1000 ft reel Numbe r of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Diamete r over Armor Approximate Net Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC (1) 14 (1) white/black (1) 14 (1) white/black/red (1) 14 (1) white/black/red/blue ¹ 15¹ 15¹ (1) 12 (1) white/black (1) 12 (1) white/black/red (1) 12 (1) white/black/red/blue ¹ 20¹ 20¹ (1) 10 (1) white/black (1) 10 (1) white/black/red (1) 10 (1) white/black/red/blue ¹ 30¹ 30¹ (19) 12 (19) white/black (19) 12 (19) white/black/red (19) 12 (19) white/black/red/blue ¹ 20¹ 20¹ (19) 10 (19) white/black (19) 10 (19) white/black/red (19) 10 (19) white/black/red/blue ¹ 30¹ 30¹ (19) 10 (19) white/black/red (19) 8 (19) white/black/red Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B)(16) for conductors in a raceway at 30 C ambient temperatures. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AWG through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹Where the 4th (white) conductor is the neutral of a balanced 3 phase system. Version V4.0 Generated 8/2/18 Page 22 / 87

23 ENERGEX MC 120 Steel Armored SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article (A)(6) For use in Class I, Div. 2 per NEC Article (B)(1), Class II, Div.2 per NEC Article (B)(1) and Class III, Div. 1 & 2 per NEC Article with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical & physical properties Nexans ENERGEX MC 120 is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation Version V4.0 Generated 8/2/18 Page 23 / 87

24 ENERGEX MC 277 Aluminum Armored Aluminum Armored MC Cable 277 Volts and Special Color Codes UL Type MC, 600 V, 90ºC dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 ENERGEX MC 277 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction in accordance with NEC Article 330. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles , (C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans MC 277 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 12 AWG to 6 AWG. Insulation:Colored PVC/Nylon Type THHN in accordance with UL 83, flame retardant, meeting UL VW-1 flame test. Ground Wire:Green PVC/Nylon Type THHN insulation sized in accordance with NEC and UL. Assembly:Conductors are cabled with grounding wires. A marker tape / core protection tape combination assembles the core in an essentially round configuration. Armor:Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E Specifications Meets UL 83: Thermoplastic-Insulated Wire and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 Page 24 / 87

25 ENERGEX MC 277 Aluminum Armored CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 Page 25 / 87

26 ENERGEX MC 277 Aluminum Armored ENERGEX MC 277 ALUMINUM ARMORED MC CABLE Part Number 250 ft coil 1000 ft reel Number of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal DiameteApproximate r Net over Armor Cable Weight indicative ratings only see and shall NEC not be binding Table on Nexans (B)(16). or be treated as constituting a representation on the part of Nexans. Version V4.0 Generated 8/2/18 Page 26 / 87 Ampacity* (Amps) inches mm lb/kft kg/km 60 C 75 C 90 C (1) 12 (1) brown/gray (1) 12 (1) orange/gray (1) 12 (1) yellow/gray (1) 12 (1) purple/gray (1) 12 (1) brown/yellow (1) 12 (1) red/white (1) 12 (1) blue/white (1) 12 (1) brown/orange/gray (1) 12 (1) brown/purple/gray (1) 12 (1) purple/yellow/gray (1) 12 (1) brown/yellow/gray (1) 12 (1) red/blue/white (1) 12 (1) black/blue/white (1) 12 (1) brown/orange/yellow/gray ¹ 20¹ 20¹ (1) 12 (1) brown/purple/yellow/gray ¹ 20¹ 20¹ (1) 10 (1) brown/gray (1) 10 (1) brown/orange/gray (1) 10 (1) brown/orange/yellow/gray ¹ 30¹ 30¹ (19) 12 (19) brown/gray (19) 12 (19) brown/orange/gray (19) 12 (19) brown/orange/yellow/gray ¹ 20¹ 20¹ (19) 10 (19) brown/gray (19) 10 (19) brown/orange/gray (19) 10 (19) brown/orange/yellow/gray ¹ 30¹ 30¹ 500 ft reel 1000 ft reel (19) 10 (19) brown/orange/gray (19) 8 (19) brown/orange/gray Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B)(16) for conductors in a raceway at 30 C ambient temperatures. 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AWG through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G).. ¹Where the 4th (gray) conductor is the neutral of a balanced 3 phase system.

27 ENERGEX MC 277 Aluminum Armored SELLING INFORMATION Product features * Cables are UL listed as Type MC, 600 V * UL listed insulated conductors * Fire Wall Penetration rated depending on type of installation and fire-stop system used * UL listed for use in cable trays per NEC Article (A)(6) * For use in Class I, Div. 2 per NEC Article (B)(1), Class II, Div. 2 per NEC Article (B)(1)(6) and Class III, Div. 1 & 2 per NEC Article with approved termination fittings. * Temperature rating of 90 C dry * Excellent mechanical & physical properties * Lightweight aluminum armor * Nexans ENERGEX MC 277 is RoHS compliant Options The following constructions can be provided on special orders: * Special conductor counts * XHHW-2 insulation Version V4.0 Generated 8/2/18 Page 27 / 87

28 ENERGEX MC Aluminum Feeder Cable Industrial Cables Aluminum Interlock Armored Power Feeder Cable, UL Type MC, 600 V, 90 C dry rated - Unjacketed, 3 or 4 aluminum conductors - XLPE insulated, with bare aluminum ground wire - LEAD FREE STANDARDS National UL 1569; UL 44 DESCRIPTION Applications Unjacketed aluminum conductor MC cable is suitable and allowed by the NEC for use in the following applications: Power lighting, control and signal circuits and as branch circuits and power feeders in industrial, commercial, institutional and residential installations up to 600 volts. Fished or embedded in plaster and concrete except in damp or wet locations. Aerial cable when fixed to a messenger support cable. Concealed or exposed applications. Cable trays and other raceways. Class I and II, Division 2 as well as Class III, Division 1 and 2 hazardous locations. Under raised floors of information technology rooms. Environmental air-handling spaces per NEC Article (C). Places of Assembly per NEC Article and theaters per NEC Article Construction Conductor: Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836 (Single Input Wire). Insulation: Colored crosslinked polyethylene (XLPE) type XHHW-2 per UL 44. Ground Wire: Bare compact stranded AA-8000 series aluminum alloy (ACM). Assembly: Insulated conductors are cabled with a bare ground wire, interstices are filled with suitable non-hygroscopic fillers, as required. A binder tape of synthetic material assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied over the assembled core. Conductor Identification: 3/C black, red, white 4/C black, red, blue, white Specifications Meets UL 44, XHHW V conductors Meets UL 1569 requirements for Type MC, Metal Clad cables Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 Page 28 / 87

29 ENERGEX MC Aluminum Feeder Cable Industrial Cables CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C ENERGEX MC ALUMINUM FEEDER CABLE 3 Conductors with Bare Ground Part Number (Color Coded Conductors) Conductor Size Insulation Thickness Ground Wire Size Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) AWG/kcmil mils mm AWG inches mm lb/kft kg/km 60ºC 75ºC 90ºC * * 1/ * 2/ * 3/ * 4/ * * * * / *Denotes stock item. Other constructions available upon request. Version V4.0 Generated 8/2/18 Page 29 / 87

30 ENERGEX MC Aluminum Feeder Cable Industrial Cables 3 CONDUCTORS WITH BARE GROUND CONNECTORS Cable Part Number (Color Coded Conductors) Conductor Size Crouse Hinds / Eaton Bridgeport Appleton AWG or kcmil ACB Series DC2 DCX2 AC ACB DC2 AC ACB DC2 AC ACB DC2 683-DCX2 AC ACB DC2 684-DCX2 AC /0 ACB DC2 684-DCX2 AC /0 ACB DC2 685-DCX2 AC /0 ACB DC2 685-DCX2 AC /0 ACB DC2 685-DCX2 AC ACB DC2 686-DCX2 AC ACB DC2 AC ACB DC2 AC ACB DC2 687-DCX2 AC ACB DC2 688-DCX2 AC-250-D Version V4.0 Generated 8/2/18 Page 30 / 87

31 ENERGEX MC Aluminum Feeder Cable Industrial Cables ENERGEX MC ALUMINUM FEEDER CABLE 4 Conductors with Bare Ground Part Number (Color Coded Conductors) Conductor Size Insulation Thickness Ground Wire Size Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) AWG/kcmil inches mm AWG inches mm lb/kft kg/km 60ºC 75ºC 90ºC * * 1/ * 2/ / * 4/ * * / / * * / Bending Radius: Fixed position: 7 x cable overall diameter During pulling: 12 x cable overall diameter 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 6 AWG throug h 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AW G. 90 C - For ampacity derating purposes. Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature and 90 C rated conductors. Ampacities for four conductor cables apply where the 4th conductor is the neutral of a balanced 3 phase system. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). For load diversity of 50%, refer to NEC Table B (B)(2)(11). * Denotes stock item. Other constructions available upon request. Version V4.0 Generated 8/2/18 Page 31 / 87

32 ENERGEX MC Aluminum Feeder Cable Industrial Cables 4 CONDUCTORS WITH BARE GROUND CONNECTORS Cable Part Number (Color Coded Conductors) Conductor Size Crouse Hinds / Eaton Bridgeport Appleton AWG or kcmil ACB Series DC2 DCX2 AC ACB DC2 AC ACB DC2 683-DCX2 AC ACB DC2 684-DCX2 AC ACB DC2 684-DCX2 AC /0 ACB DC2 685-DCX2 AC /0 ACB DC2 685-DCX2 AC /0 ACB DCX2 AC /0 ACB DCX2 AC ACB DC2 686-DCX2 AC ACB DC2 686-DCX2 AC ACB DC2 687-DCX2 AC ACB DC2 687-DCX2 AC ACB DC2 687-DCX2 AC ACB DC2 688-DCX2 AC-250-D ACB DC2 688-DCX2 AC-250-D ACB DC2 688-DCX2 AC-250-D ACB DC2 689-DCX2 AC-250-D SELLING INFORMATION Product Features Cables are UL listed as Type MC, rated 600 V UL listed XHHW-2 insulated conductors Cables pass UL 1685 and IEEE 383 vertical tray fire tests at 70,000 BTU/hr, ICEA T fire test at 210,000 BTU/ hr, IEEE 1202 and CSA FT4 Fire wall penetration rated depending on type of installation and fire-stop system used Cables exhibit a -25 C cold bend rating with suitable precautions Temperature rating of 90 Cdry 130 C emergency rating and 250 C short circuit rating Excellent mechanical and physical properties RoHS Compliant Suitable for use in cabletray Can be installed in hazardous locations as permitted by the NEC Version V4.0 Generated 8/2/18 Page 32 / 87

33 ENERGEX MC Ground Plus Aluminum Armored Isolated Ground MC Cable UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC Ground Plus cables are for use in applications where isolated, dedicated or redundant ground is required. They may be used for branch, feeder and service for distribution in commercial, industrial and multi-residential construction. They are also suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles , (C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans MC Ground Plus cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 8 AWG and 6 AWG. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Ground Wires: Sized in accordance with NEC and UL, one with green THHN insulation, one with green THHN insulation with a yellow stripe. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version 4.0 Generated 8/2/18 Page 33 / 87

34 ENERGEX MC Ground Plus CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 Page 34 / 87

35 ENERGEX MC Ground Plus ENERGEX MC GROUND PLUS Part Number 250 ft coil 1000 ft reel Number of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Approximate Diameter Net over Jacket Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC (1) 2 x 14 (1) white/black (1) 2 x 14 (1) white/black/red (1) 2 x 14 (1) white/black/red/blue ¹ 15¹ 15¹ (1) 2 x 12 (1) white/black (1) 2 x 12 (1) white/black/red (1) 2 x 12 (1) white/black/red/blue ¹ 20¹ 20¹ (1) 2 x 10 (1) white/black (1) 2 x 10 (1) white/black/red (1) 2 x 10 (1) white/black/red/blue ¹ 30¹ 30¹ (19) 2 x 10 (1) white/black (19) 2 x 10 (1) white/black/red (19) 2 x 10 (1) white/black/red/blue ¹ 50¹ 55¹ (19) 2 x 8(19) white/black (19) 2 x 8(19) white/black/red (19) 2 x 8(19) white/black/red/blue ¹ 65¹ 75¹ Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B) (16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temprature a nd number of conductors have been applied. Exceptions to this may be covered in NEC Article (E) through (G). ¹ Where the 4th (white) conductor is the neutral of a balanced 3 phase system. Version 4.0 Generated 8/2/18 Page 35 / 87

36 ENERGEX MC Ground Plus SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article (A)(6) For use in Class 1, Div. 2 per NEC Article (B)(1), Class II, Div.2 per NEC Article (B)(1) and Class III, Div. 1 & 2 per NEC Article with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Nexans ENERGEX MC Ground Plus is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW insulation Version 4.0 Generated 8/2/18 Page 36 / 87

37 ENERGEX MC Mega Neutral Aluminum Armored MC Cable, UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC Mega Neutral cables are for use in applications where increased neutral capacity is required due to non-linear switching loads which can cause additive harmonic currents to be present on the neutral conductors. They may be used for branch, feeder and service for distribution in commercial, industrial, and multiresidential construction. It is also suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles , (C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) ONLY. Nexans MC Mega Neutral Cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 8 AWG and 6 AWG. Insulation: PVC/Nylon Type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Neutral Conductor: Soft copper, with white THHN insulation and colored stripe where indicated. Cable has either one neutral per phase conductor or one over-sized neutral per two phase conductors. Ground Wire(s): Sized in accordance with NEC and UL, one with green THHN insulation, one with green THHN insulation with a yellow stripe (in cables with two grounds). Assembly: Conductors are cabled with neutrals and grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS TYPE MC 600V FOR CT USE 12/4C - 10/2C THHN (UL) E Version 4.0 Generated 8/2/18 Page 37 / 87

38 ENERGEX MC Mega Neutral Specifications Meets UL 83: Thermoplastic-Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version 4.0 Generated 8/2/18 Page 38 / 87

39 ENERGEX MC Mega Neutral CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 Page 39 / 87

40 ENERGEX MC Mega Neutral ENERGEX MC MEGA NEUTRAL Neutral Per Leg (NPL) Part Number 250 ft coil 1000 ft reel Number ofconductor Power Size Conductors AWG Neutral Size AWG Ground Size AWG Circuit Conductor Color Code NominalApproximate Diameter Net White Neutralover Armor Cable Weight Stripe Color Ampacity (Amps) inchesmmlb/kft kg/km 60ºC75ºC90ºC (1) 2x12 (1) 2x12 (1) black/red black/red (1) 3x12 (1) 2x12 (1) black/red/blue black/red/blue (1) 3x12 (1) 2x12 (1)black/red/pink/tan none/pink/tan ¹ 20¹ 20¹ (1) 2x10 (1)2x10 (1) black/red black/red (1) 3x10 (1)2x10 (1) black/red/blue black/red/blue Oversize Neutral Conductor (ONC) Part Number 250 ft coil 1000 ft reel Number ofconductor Power Size Conductors AWG Neutral Size AWG Ground Size AWG Circuit Conductor Color Code NominalApproximate Diameter Net White Neutralover Armor Cable Weight Stripe Color Ampacity (Amps) inchesmmlb/kft kg/km 60ºC75ºC90ºC (1) 10 (1) 12 (1) black no stripe (1) 10 (1) 12 (1) black/red no stripe (1) 10 (1) 12 (1) black/red/blue no stripe (1) 8 (19) 12 (1) black/red/blue no stripe (1) 2x10 (1)2x12 (1)black/red/blue/pink none/pink ¹ 20¹ 20¹ (1) 8 (19) 10 (1) black/red no stripe (1) 6 (19) 10 (1) black/red/blue no stripe (1) 2x8 (19)2x10 (1)black/red/blue/pink none/pink ¹ 30¹ 30¹ Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B) (16) for conductors in a raceway or direct buried at 30 C ambient temperatures. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). NEC Article (D) requires that overcurrent protection not exceed 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductor s have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹Where the 4th (white) conductor is the neutral of a balanced 3 phase system. Version 4.0 Generated 8/2/18 Page 40 / 87

41 ENERGEX MC Mega Neutral SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article (A)(6) For use in Class 1, Div. 2 per NEC Article (B)(1), Class II, Div.2 per NEC Article (B)(1) and Class III, Div. 1 & 2 per NEC Article (A) and (B) with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Nexans ENERGEX MC Mega Neutral is RoHs compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation Version 4.0 Generated 8/2/18 Page 41 / 87

42 ENERGEX MC Multi Conductor Aluminum Armored MC Cable UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC Multi Conductor cables are designed for applications that require six or more conductors. They may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles , (C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article (C) only. Nexans MC Multi Conductor Cables are RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Ground Wire: Green PVC/Nylon Type THHN insulation, sized in accordance with NEC and UL. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E Color Code: (tan is stripe color) 6 conductor: black, red, white, black/tan, red/tan, white/tan 8 conductor: black, red, white, blue, black/tan, red/tan, white/tan, blue/tan Version V4.0 Generated 8/2/18 Page 42 / 87

43 ENERGEX MC Multi Conductor Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 Page 43 / 87

44 ENERGEX MC Multi Conductor CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 Page 44 / 87

45 ENERGEX MC Multi Conductor ENERGEX MC MULTI CONDUCTOR Part Number 1000 ft reels Number of Conductors Conductor Size AWG Ground Size AWG Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC (1) 12 (1) (1) 12 (1) (1) 12 (1) (1) 12 (1) (1) 12 (1) (1) 12 (1) (1) 12 (1) (1) 12 (1) (1) 12 (1) (1) 10 (1) (1) 10 (1) (1) 10 (1) (1) 10 (1) (1) 10 (1) (1) 10 (1) (1) 10 (1) (1) 10 (1) (1) 10 (1) Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). SELLING INFORMATION Product Features Version V4.0 Generated 8/2/18 Page 45 / 87

46 ENERGEX MC Multi Conductor Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article (A)(6) For use in Class 1, Div. 2 per NEC Article (B)(6), Class II, Div.2 per NEC Article (B)(1) and Class III, Div. 1 & 2 per NEC Article with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Nexans ENERGEX MC Multi Conductor is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW insulation Version V4.0 Generated 8/2/18 Page 46 / 87

47 Direct Buried Armored and unarmored cable are available for direct burial in the earth with appropriate protection as required by the local inspection authority. All are designed for ease of installation and superior performance. Generated 8/2/18 Page 47 / 87

48 ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum XLPE Insulated Cable, ACM Aluminum Conductors, 600 Volts, 90ºC Dry or Wet - RoHS compliant DESCRIPTION STANDARDS National ICEA S ; UL 854; UL 44 Application Nexans ENERGEX 8000 RHH/RHW-2/USE-2 is an AA-8000 series aluminum (ACM) conductor with cross-linked polyethylene insulation. The cable may be installed in raceways and conduits or directly buried. They are 90ºC, 600 volts per NEC Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, cables are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are RoHS compliant. Construction Conductor: Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 or ASTM B836 (Single Input Wire). Insulation: Heat, sunlight, moisture and abrasion resistant cross-lined polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854: (USE-2) Service Entrance Cables Federal Specification A-A ICEA : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy National Electrical Code - NFPA 70 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated CT use. Surface Print Legend (example) NEXANS-C 1/0 AWG COMPACT AA-8000-AL USE-2 OR RHH OR RHW-2 600V FOR CT USE SUN RES(UL) ROHS (MFG. DATE) Version 4.0 Generated 8/2/18 Page 48 / 87

49 ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 Page 49 / 87

50 ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum ENERGEX 8000 RHH/RHW 2/USE 2 ALUMINUM Conductor Size Nominal Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 ºC 75 ºC 90 ºC 6 (7) (7) (7) (18) /0 (18) /0 (18) /0 (18) /0 (18) (35) (35) (35) (35) (35) (58) (58) (58) (58) *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC Article , which are based on NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). NEC Article 240.4(D) requires that over current protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). SELLING INFORMATION Product Features Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Version 4.0 Generated 8/2/18 Page 50 / 87

51 ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum Suitable for direct burial Sunlight resistant RoHS compliant Bare conductors are heat treated after stranding for maximum flexibility Version 4.0 Generated 8/2/18 Page 51 / 87

52 ENERGEX RHH/RHW 2/USE 2 Copper XLPE Insulated Cable 600 Volts, 90ºC Dry or Wet - LEAD FREE NEC ART 310 and 338 Copper Conductors DESCRIPTION STANDARDS National ICEA S ; UL 854; UL 44 Application Nexans ENERGEX RHH/RHW-2/USE-2 conductors may be installed in raceways and conduits or directly buried. They are 90ºC, 600 volts per NEC Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, cables are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are LEAD FREE and RoHS compliant. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-lined polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A ICEA National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use Surface Print Legend (example) NEXANS 1/0 AWG (53.5 mm2) (UL) E64801 F RHW-2 OR USE-2 600V FOR CT USE SR MADE IN CANADA LEAD FREE (MFG DATE). Version V2.0 Generated 8/2/18 Page 52 / 87

53 ENERGEX RHH/RHW 2/USE 2 Copper CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V2.0 Generated 8/2/18 Page 53 / 87

54 ENERGEX RHH/RHW 2/USE 2 Copper ENERGEX 8000 RHH/RHW 2/USE 2 COPPER 600 V Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 14 (1) (1) (1) (7) (7) (7) (7) (7) (7) (19) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) (61) Version V2.0 Generated 8/2/18 Page 54 / 87

55 ENERGEX RHH/RHW 2/USE 2 Copper *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC Article , which are based on NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). NEC Article 240.4(D) required that over current protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). SELLING INFORMATION Product Features Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant LEAD FREE and RoHS compliant. Version V2.0 Generated 8/2/18 Page 55 / 87

56 Conduit Wire & Cable Unarmoured Nexans wire and cable is generally installed in conduit or underground duct in dry, damp and wet locations depending on the product construction. All are designed for ease of installation and superior performance. Generated 8/2/18 Page 56 / 87

57 ENERGEX 8000 Aluminum XHHW 2 XLPE Insulated Cable, ACM Aluminum Conductors, 600 Volts, 90ºC Dry or Wet - RoHS Compliant DESCRIPTION Application Nexans ENERGEX 8000 XHHW-2 is an AA-8000 series aluminum (ACM) conductor with cross-linked polyethylene insulation. The cable is rated at 600 volts and 90ºC for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC. Sizes 12 AWG to 4/0 AWG are approved as SIS. Nexans XHHW-2 is RoHS compliant. STANDARDS National ICEA S ; UL 44 Construction Conductor: Compact stranded AA-8000 series aluminum alloy (ACM) per ASTM B801 or B836. Insulation: Black, sunlight resistant, cross-linked polyethylene (XLPE) meeting the requirements for XHHW-2 per UL 44. Specifications Nexans ENERGEX 8000 Type XHHW-2 meets or exceeds all applicable ASTM specifications UL 44: Thermoset - Insulated Wires and Cables NEC Article Federal Specification A-A and the requirements of the NEC Meets or exceeds the requirements of NEMA WC 70 / ICEA S : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Sunlight resistant in black 8 AWG and larger Sizes 12 AWG to 4/0 AWG rated SIS Voltage rating Volts Meets IEEE 1202 Surface Print Legend (example) NEXANS-C 1/0 AWG COMPACT AA-8000-AL XHHW-2 600V SR ROHS (UL) (MFG. DATE) Version V5.0 Generated 8/2/18 Page 57 / 87

58 ENERGEX 8000 Aluminum XHHW 2 CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V5.0 Generated 8/2/18 Page 58 / 87

59 ENERGEX 8000 Aluminum XHHW 2 ENERGEX 8000 XHHW 2 ALUMINUM Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (Amps) mils mm inches mm lb/kft kg/km 60 ºC 75 ºC 90 ºC / / / / *60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 AWG through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacity are in accordance with NEC Article , which are based on NEC Table (B)(16) for aluminum conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). NEC Article 240.4(D) required that over current protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). Version V5.0 Generated 8/2/18 Page 59 / 87

60 ENERGEX 8000 Aluminum XHHW 2 PACKAGE QUANTITIES AND PART NUMBERS Conductor Size AWG/kcmil Package Quantity / Part Number 500 ft reel 1000 ft reel 5000 ft reel Long Length Cutting Reels / / / / SELLING INFORMATION Product Features Cables are UL listed as Type XHHW-2 Temperature rating of 90ºC dry and wet Sunlight Resistant, black 8 AWG and larger RoHS compliant Bare conductors are heat treated after stranding for maximum flexibility Sizes 12 AWG - 4/0 AWG rated SIS Options Rating for CT use available in conductor sizes 1/0 AWG and larger (4 AWG and larger in green). Version V5.0 Generated 8/2/18 Page 60 / 87

61 ENERGEX INSTAGLIDE THHN / THWN 2 / MTW PVC/Nylon Cable, Copper Conductors, 600 Volts, 90 C dry rated - LEAD FREE DESCRIPTION Application Nexans ENERGEX INSTAGLIDE THHN / THWN-2 / MTW is a general purpose wiring product for use in power, lighting and control circuits. It can be used in conduit, ducts and trays for service feeders and branch circuits in industrial and commercial installations. When used in accordance with the NEC, THHN / THWN-2 is suitable for use in wet and dry locations, at conductor temperatures not exceeding 90ºC or for use in oil or coolants at conductor temperatures not exceeding 75ºC. THHN / THWN-2 is gasoline and oil resistant II. When used as Machine Tool Wire (MTW) it is rated at 90ºC in dry locations and 60ºC in wet locations or when exposed to oil or coolants. STANDARDS National CSA C22.2 N 75; ICEA S ; UL 1063; UL 83 Nexans ENERGEX INSTAGLIDE THHN / THWN-2/ MTW wire is RoHS compliant. Nexans INSTAGLIDE reduced friction construction in sizes 6 AWG and larger. Construction Conductor: Solid bare, annealed copper per ASTM B3. Stranded bare annealed copper per ASTM B3 and ASTM B8 Class C compressed for sizes 14 AWG to 2 AWG, and ASTM B8 Class B unilay compressed for sizes 1 AWG and larger. Insulation: Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound per UL 83 and UL Covering: A tough abrasion resistant polyamide (Nylon) covering. Specifications Nexans ENERGEX INSTAGLIDE THHN / THWN-2 or MTW meets or exceeds all applicable ASTM specifications UL 83: Thermoplastic-Insulated Wires and Cables UL 1063: Machine-Tool Wires and Cables (stranded cables only) NEMA WC70 / ICEA S : Power Cables Rated 2000V or Less for the Distribution of Electrical Energy Federal Specification A-A and requirements of the NEC CSA C22.2 No. 75: Thermoplastic Insulated Wires and Cables 14 AWG through 750 kcmil are rated VW-1. Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated CT use Black sizes 1/0 AWG and larger are sunlight resistant Rated 600 volts Sizes 8 AWG and larger sequentially marked every 2 feet. Surface Print Legend (example) NEXANS-C INSTAGLIDE 500 kcmil (253mm2) TYPE MTW OR THHN OR THWN-2 GRII SR FOR CT USE VW-1 600V (UL) RoHS (MFG. DATE) Version V6.0 Generated 8/2/18 Page 61 / 87

62 ENERGEX INSTAGLIDE THHN / THWN 2 / MTW CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V6.0 Generated 8/2/18 Page 62 / 87

63 ENERGEX INSTAGLIDE THHN / THWN 2 / MTW ENERGEX INSTAGLIDE THHN / THWN 2 / MTW COPPER Conductor Size PVC Insulation Thickness Nylon Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (Amps) AWG/kcmil mils mils inches lbs/kft 60ºC 75ºC 90ºC 14 (1) (1) (1) (19) (19) (19) (19) (19) (19) (19) (19) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. For MTW in wet locations or when exposed to oil or coolant. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. THWN 2 when exposed to oil or coolant. 90 C THHN dry locations. THWN 2 wet or dry locations. For ampacity derating purposes. Available colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Purple, Gray, Pink. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC Article , which are based on NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table (B)(16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). Version V6.0 Generated 8/2/18 Page 63 / 87

64 ENERGEX INSTAGLIDE THHN / THWN 2 / MTW SELLING INFORMATION Product Features Nexans INSTAGLIDE reduced friction construction in sizes 6 AWG and larger. Sizes 8 AWG to 600 kcmil available in various colors from stock Cables are UL listed as Type THHN / THWN-2/ MTW Meets UL VW-1 flame test requirements Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated CT use Black sizes 1/0 AWG and larger are sunlight resistant Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant insulation system THWN-2 90ºC rated for dry and wet locations Gasoline and Oil Resistant II Small diameter for improved conduit fill RoHS compliant Packaging 14 AWG & 12 AWG: 4 x 500' spools (2000' per carton) or 2500' reel 10 AWG: 2 x 500' spools (1000' per carton) or 2500' reel 8 AWG kcmil: 500', 1000', 2500' or 5000' reel 400 kcmil kcmil: 500', 1000', or 2500' reel 600 kcmil kcmil: 500' reel * Only stranded cables are MTW listed per UL Version V6.0 Generated 8/2/18 Page 64 / 87

65 ENERGEX INSTAGLIDE XHHW 2 Copper XLPE Insulated Cable, Copper Conductors, 600 Volts, 90ºC Dry or Wet - LEAD FREE DESCRIPTION Application Nexans ENERGEX INSTAGLIDE XHHW-2 is a copper conductor, with cross-linked polyethylene insulation. The cable is rated at 600 volts and 90 C for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC. Sizes 14 AWG to 4/0 AWG are approved as Type SIS. Sizes 1/0 AWG and larger (4 AWG and larger in green) in all colors are cable tray (CT) rated. Nexans ENERGEX INSTAGLIDE XHHW-2 conductors are RoHS compliant. Nexans INSTAGLIDE reduced friction construction in sizes 6 AWG and larger. STANDARDS National ICEA S ; UL 44 Construction Conductor: Annealed soft bare copper per ASTM B3, B787 and B8 Insulation: Cross-linked polyethylene (XLPE) insulation per UL 44 Surface Print Legend (example) NEXANS EXELENE 500 kcmil (253 mm2) XHHW-2 (UL) E64801 F 600V FOR CT USE SR - MADE IN CANADA LEAD FREE (MFG. DATE) Specifications Nexans ENERGEX Type XHHW-2 meets or exceeds all applicable ASTM specifications. UL 44: Thermoset-Insulated Wire and Cables Federal Specification A-A and the requirements of the NEC. NEMA WC70 / ICEA S : Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy. Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) rated for CT use. Sunlight resistant in black 8 AWG and larger. 14 AWG to 10 AWG are available in 10 distinct colors for identification purposes. Sizes 14 AWG to 4/0 AWG rated SIS. Nexans XHHW-2 is LEAD FREE. Voltage rating Volts. Version V3.0 Generated 8/2/18 Page 65 / 87

66 ENERGEX INSTAGLIDE XHHW 2 Copper CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V3.0 Generated 8/2/18 Page 66 / 87

67 ENERGEX INSTAGLIDE XHHW 2 Copper ENERGEX INSTAGLIDE XHHW 2 COPPER Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 14 (7) (7) (7) (7) (7) (7) (7) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) (61) *60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacity are in accordance with NEC Article , which are based on NEC Table or NEC Table (B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table or NEC Table (B)(16). NEC Article 240.4(D) required that over current protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). Version V3.0 Generated 8/2/18 Page 67 / 87

68 ENERGEX INSTAGLIDE XHHW 2 Copper SELLING INFORMATION Product Features Sizes 14 AWG to 10 AWG are available in 10 colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Gray, Purple. Size 8 AWG and larger in black only. Meets IEEE 1202 Conforms to ICEA S Sunlight Resistant 8 AWG and larger in black Conductor sizes 1/0 AWG and larger (4 AWG and larger in green are rated for CT use Sizes 14 AWG to 4/0 AWG rated SIS Meets or exceeds all applicable industry standards LEAD FREE Packaging 14 AWG to 10 AWG 2 x 500 spools (1000 feet) per carton; 2500 reel 8 AWG to 600 kcmil long length 750 kcmil 500 reel or long length Version V3.0 Generated 8/2/18 Page 68 / 87

69 Components, Specialty & Bare Copper Cables specially designed for unique installation requirements. Generated 8/2/18 Page 69 / 87

70 ENERGEX PV/RHH/RHW 2/USE 2 DESCRIPTION Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. STANDARDS National ICEA S ; UL 854; UL 854 Subject 4703; UL 44 Version 2.0 Generated 8/2/18 Page 70 / 87

71 Commercial Building Wire & Cable Aluminum 2 kv Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S ; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836 (Single Input Wire). Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Surface Print Legend (example) (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) CPT ACM ALUM (UL) USE-2 600V OR RHW-2 OR PV WIRE 2000V 90C WET OR DRY SR DIR BUR LEAD FREE Version 2.0 Generated 8/2/18 Page 71 / 87

72 Commercial Building Wire & Cable Aluminum 2 kv CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 2000 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 Page 72 / 87

73 Commercial Building Wire & Cable Aluminum 2 kv ENERGEX PV/RHH/RHW 2/USE 2 ALUMINUM 2 KV Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC / / / / ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes #6 through #1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than #1 AWG. 90ºC RHH dry locations. PV and RHW 2 wet or dry locations. For ampacity derating purposes. For conductors installed in conduit on a roof top, use the derating factors specified by Table (B)(3)(c) in the NEC. * Allowable ampacities shown are for general use as specified by the NEC, Section SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger are rated CT use LEAD FREE Options Class C stranding available Version 2.0 Generated 8/2/18 Page 73 / 87

74 Commercial Building Wire & Cable Aluminum 600 V Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S ; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 600 V per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor:Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836 (Single Input Wire). Insulation:Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RWH-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Surface Print Legend (example) (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) CPT ACM ALUM (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE Version 2.0 Generated 8/2/18 Page 74 / 87

75 Commercial Building Wire & Cable Aluminum 600 V CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 Page 75 / 87

76 Commercial Building Wire & Cable Aluminum 600 V ENERGEX PV/RHH/RHW 2/USE 2 ALUMINUM 600 V Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC / / / / ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes #6 through #1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than #1 AWG. 90ºC RHH dry locations. PV, RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. For conductors installed in conduit on a roof top, use the derating factors specified by Table (B)(3)(c) in the NEC. * Allowable ampacities shown are for general use as specified by the NEC, Section SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 and larger are rated CT use LEAD FREE Options Class C stranding available Version 2.0 Generated 8/2/18 Page 76 / 87

77 Commercial Building Wire & Cable Copper 2 kv Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S ; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Version 2.0 Generated 8/2/18 Page 77 / 87

78 Commercial Building Wire & Cable Copper 2 kv Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E (PV), E49786 (USE-2), E64801 (RHH, RHW-2 Surface Print Legend (example) (mon/year) NEXANS [plt] 350 kcmil (177.3 mm2) (UL) USE-2 600V OR RHW-2 OR PV WIRE 2000V 90C WET OR DRY SR DIR BUR LEAD FREE CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 2000 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 Page 78 / 87

79 Commercial Building Wire & Cable Copper 2 kv ENERGEX PV/RHH/RHW 2/USE 2 COPPER 2 KV Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 8 (7) (7) (7) (7) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) (61) ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. PV, RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. * Allowable ampacities shown are for general use as specified by the NEC, Section For conductors installed in conduit on a roof top, use the derating factors specified by Table (B)(3)(c) in the NEC. Note: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Coductors 1/0 AWG and larger are rated CT use LEAD FREE Version 2.0 Generated 8/2/18 Page 79 / 87

80 Commercial Building Wire & Cable Copper 2 kv Options Class C stranding available Version 2.0 Generated 8/2/18 Page 80 / 87

81 Commercial Building Wire & Cable Copper 600 V Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S ; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 600 V or 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. Type RHH cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Version 2.0 Generated 8/2/18 Page 81 / 87

82 Commercial Building Wire & Cable Copper 600 V Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Surface Print Legend (example) (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 Page 82 / 87

83 Commercial Building Wire & Cable Copper 600 V ENERGEX PV/RHH/RHW 2/USE 2 COPPER 600 V Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 8 (7) (7) (7) (7) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) (61) *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. PV, RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. Allowable ampacities shown are for general use as specified by the NEC, Section For conductors installed in conduit on a roof top, use the derating factors specified by Table (B)(3)(c) in the NEC. Note: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger are rated CT use LEAD FREE Version 2.0 Generated 8/2/18 Page 83 / 87

84 Commercial Building Wire & Cable Copper 600 V Options Class C stranding available Version 2.0 Generated 8/2/18 Page 84 / 87

85 Soft Bare Copper USA* Bare Copper Conductors DESCRIPTION ASTM B-3 Soft or Annealed Copper Wire. ASTM B-3 Specification details the requirements for solid wires and the individual wires in stranded conductors. ASTM B-8 Concentric - Lay - Stranded Copper Conductors Solid or stranded 100% conductivity copper conductors. Application Used for bonding and grounding electrical circuits and systems. STANDARDS CHARACTERISTICS Construction characteristics Conductor material National Factory standard Annealed copper Version V2.0 Generated 8/2/18 Page 85 / 87

86 Soft Bare Copper USA* SOFT DRAWN BARE COPPER Size AWG or kcmil Nominal Diameter Approximate Conductor Weight Nominal D.C. 25 C mm in kg/km lbs/kft Ω/km Ω/kft 14 (1) (1) (1) (7) (7) (7) (7) (19) /0 (19) /0 (19) /0 (19) /0 (19) (37) (37) (37) (37) (37) (61) (61) (61) * ASTM B-3 Specification details the requirements for solid wires and the individual wires in stranded conductors. Version V2.0 Generated 8/2/18 Page 86 / 87

87 Nexans US - United States globalsalessupport.us@nexans.com Distributed by

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION Armorlite Type MC Lightweight Aluminum Interlocked Armor. 600 Volts. Copper Power Conductors. THHN/THWN Insulated Singles. Green Insulated Grounding Conductor. Sizes 14 AWG through 2 AWG. Rated VW-1. APPLICATIONS

More information

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight. 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category MC122IG 12/2

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

Mecklenburg County Common Code Defects

Mecklenburg County Common Code Defects Electrical Code Defects Improper Over Current Protection Code Description 310.15 Ampacities for s Rated 0 2000 Volts. (A) General. (1) Tables or Engineering Supervision. Ampacities for conductors shall

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES Introduction When it comes to feeder cables, General Cable keeps industries of all types humming with cost savings on total installation,

More information

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum

More information

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable

More information

Primary, Secondary, Post-Secondary Education Facilities

Primary, Secondary, Post-Secondary Education Facilities STABILOY Feeder Solutions Primary, Secondary, Post-Secondary Education Facilities Introduction At Alcan Cable your children s safety is our top concern. That is why our STABILOY aluminum alloy feeder cables

More information

ATHLETIC STADIUMS AND SPORTS ARENAS

ATHLETIC STADIUMS AND SPORTS ARENAS STABILOY Brand Feeder Solutions ATHLETIC STADIUMS AND SPORTS ARENAS Introduction Stadiums of all shapes and sizes require a consistent source of power to keep their fans happy. At General Cable, dependability

More information

HOSPITAL AND HEALTHCARE

HOSPITAL AND HEALTHCARE STABILOY Brand Feeder Solutions HOSPITAL AND HEALTHCARE Introduction General Cable understands that hospitals require complex buiding designs that must address a wide range of systems and applications.

More information

Medium Voltage Power Cables

Medium Voltage Power Cables Medium Voltage Power s Distribution s (CN s) are suitable for use above ground in open air, in conduit in air, directly buried, in underground duct, or aerially when suspended on a messenger wire. CN cables

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

PART A General Conductor Requirements

PART A General Conductor Requirements PART A General Conductor Requirements 6.1 Conductor Insulation Property Table 310.13 of the NEC provides information on conductor properties such as permitted use, maximum operating temperature, and other

More information

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper THHN/THWN-2/MTW/T90 PVC Insulation with Nylon Jacket Solid or Stranded Soft-annealed Uncoated Copper Specifications ASTM (American Society for Testing & Material ASTM B3 Class B, B8 (sizes 6 and larger),

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 310 310.120 CHANGES FROM 2011 TO 2014 CODE ARE IN RED ARTICLE 310 Conductors for General Wiring I. General 310.2 Definitions Electrical Ducts Electrical conduits, or other

More information

RENEWABLE ENERGY. Alcan cable solutions

RENEWABLE ENERGY. Alcan cable solutions RENEWABLE ENERGY Alcan cable solutions Renewable Energy Broch_mech5.indd 1 5/23/11 11:02:2 AM Alcan Cable s Commitment: Cabling Solutions for Wind and Solar Farms As the demand for electrical power continues

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)... MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 UF103WG250 10/3 WG Uf Cable-250' Southwire Company Catalog Number Manufacturer Description Weight per unit Product Category

More information

TUNNELING POWER CABLES

TUNNELING POWER CABLES TUNNELING POWER CABLES Index 3- Type G-GC (Round) 3/C kv..................... -3 3-5 Type SHD-GC 3/C 5kV........................ -5 3-55 Type SHD-GC 3/C 5kV........................ - 3-0/0/0 Type MP-GC

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SEU43500 4-4-4 Seu Cable-500' Southwire Company Catalog Number SEU43500 Manufacturer Southwire Company Description Copper

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

E R C. R E R C ; ; W T E C

E R C. R E R C ; ; W T E C WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation

More information

The Reliable Choice. Field Pocket Guide

The Reliable Choice. Field Pocket Guide The Reliable Choice Field Pocket Guide Allowable Ampacities of STABILOY Brand XHHW-2 and Copper 75 C (167 F) 90 C (194 F) 75 C (167 F) 90 C (194 F) Conductor Size (AWG or kcmil) Types RHW, THHW, THW, THWN,

More information

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable SERVING THE NUCLEAR POWER MARKETS power generating plants original equipment manufacturer storage and waste management facilities

More information

KALAS ENTERTAINMENT CABLE

KALAS ENTERTAINMENT CABLE KALAS ENTERTAINMENT CABLE DELIVERING DEPENDABILITY FOR MORE THAN HALF A CENTURY Kalas is a full-service manufacturer with over 55 years of experience. We are strategically positioned to deliver quality

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

IEEE 1580 TYPE T/N CABLE

IEEE 1580 TYPE T/N CABLE 1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES 37- TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 000 VOLTS FEATURES Highly durable, abrasion-resistant CPE jacket specially designed

More information

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic

More information

Medium Voltage Cable. marmonutility.com

Medium Voltage Cable. marmonutility.com Medium Voltage marmonutility.com Table Contents Introduction... 2 Hendrix Product Information... 4 Distribution s (URD) 15kV...6 25kV... 10 35kV...12 28kV...14 Electrical Data...16 Kerite Product Information...

More information

New TITANEX PREMIUM. No limit!

New TITANEX PREMIUM. No limit! New TITANEX PREMIUM No limit! A single flexible cable... TITANEX PREMIUM meets your specific needs in many areas and industries: entertainment, motion picture and broadcasting; power supply of submerged

More information

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Spring Test 10 due 05/11/2013

Spring Test 10 due 05/11/2013 Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE CABLE SOLUTIONS to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE GENERAL CABLE DELIVERS Advanced Reliability, Safety And Sustainability To The Nuclear Power Industry Safe,

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

NEC 2011 Code Changes

NEC 2011 Code Changes NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection

More information

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable ed Primary UD TRXLP ed Primary UD TRXLP Cable Aluminum or Copper Conductor. TRXLP Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for

More information

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE EXPERIENCED. RELIABLE. TRUSTED. QUALITY. WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE KalaS headquarters KalaS los angeles 28365 Constellation Road, Unit B KalaSwIRe.COM P 717.336.5575 RELIABLE DEPENDABLE

More information

Automotive Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers

More information

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary

More information

2016 Photovoltaic Solar System Plan Review List

2016 Photovoltaic Solar System Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE

More information

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240

More information

Wired for Power Generation

Wired for Power Generation Instrumentation Cables Power Cables Control Cables Communications Cables Specialty Cables Wired for Power Generation Serving the Power Generation Market Wired for Power Generation Coax Low-Voltage Power

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

Have You Been Grounded Lately

Have You Been Grounded Lately Have You Been Grounded Lately Thurs, Oct. 26, 2017 9:15-10:15 Phil Simmons Author, Electrical Grounding and Bonding Author Cengage Learning Phil Simmons Have You Been Grounded Lately 2017 NEC Changes Relative

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER BRONCO Brand TM Premium Flexible Power Cable PHILATRON WIRE AND CABLE * USA MANUFACTURER WWW.PHILATRON.COM Table of Contents BRONCO-15 Cable & Cord Description To: Bronco-15 From: Bronco-66 History: To

More information

Spring Test 7 due 05/03/2013

Spring Test 7 due 05/03/2013 Spring Test 7 due 05/03/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A raceway contains two 3-phase, 3-wire circuits that supply 38 ampere continuous

More information

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology ANACONDA SEALTITE 2018 ANAMET Electrical, Inc. AN ANAMET COMPANY When you say SEALTITE, there is only one: ANACONDA. Type MTC Type

More information

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 REELING CABLE RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 Contents: Letter code Construction details and voltage-classes Technical data 2016 RHEYFIRM(RTS)

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to

More information

See Part 3 for the Introduction for Article 314

See Part 3 for the Introduction for Article 314 See Part 3 for the Introduction for Article 314 76 314.25 Covers and Canopies When the installation is complete, each outlet box must be provided with a cover or faceplate, unless covered by a fixture

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

Rail & Transit WIRE AND CABLE

Rail & Transit WIRE AND CABLE Rail & Transit WIRE AND CABLE OCTOBER 2014 TRANSIT Servicing the Rail & Transit Markets This catalog contains in-depth information on the most comprehensive line of rail & transit wire and cable available

More information

HIGH PERFORMANCE OVERHEAD LINE CONDUCTORS TO UPGRADE YOUR SYSTEM

HIGH PERFORMANCE OVERHEAD LINE CONDUCTORS TO UPGRADE YOUR SYSTEM HIGH PERFORMANCE OVERHEAD LINE CONDUCTORS TO UPGRADE YOUR SYSTEM ACPR LO-SAG CONDUCTOR UPGRADE YOUR INTERNAL BACKBONE AND CROSS-BORDER CAPACITY The innovative ACPR LO-SAG is much lighter & stronger, dispatching

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS JANUARY 2015 The Low Friction Advantage in Cable Installation General Cable s new High Speed industrial cable, with Xtra Low Friction

More information

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for

More information

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C 10 SOOW 90 C./;SOOW 90 C/11709 Index1.W&C Energy Products////600v Thermoset Jkt'd SOOW 90 C PR33307V2-240057.eps Synthetic rubber insulation Thermoset jacket 90 C, 600 V 1. CONDUCTOR: Bare, annealed copper

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR DIVISION 16 - ELECTRICAL SECTION 16xx0 16xx0-1. GENERAL MANUFACTURED WIRING SYSTEM ACCESS FLOOR The modular convenience power system ensures the electrification and delivery of power from the power panels

More information

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

Category # 1 - Overhead, Primary, & Secondary Conductors

Category # 1 - Overhead, Primary, & Secondary Conductors City of Alexandria Bid Proposal # 2214 Open Date - November 27, 2018 Page BF1of BF7 Category # 1 - Overhead, Primary, & Secondary Conductors 1. 2801602110 17,100 LB. CABLE, 477 MCM AAC CONDUCTOR, $ - $

More information

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked. ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES Black Crosslinked High-Density Polyethylene (XLHDPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information