Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Size: px
Start display at page:

Download "Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company"

Transcription

1 Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global Cable Solutions Company

2 Gexol World Class Index Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Assemblies Ester Based Mud Resistant Cable General Information Ampacity Ratings... Bend Radius... Hawke Gland Types.... Gexol Cable Stranding Profile... Drilling Mud Resistant Oil Resistant Fastest Lead Times Standard 8-0 weeks Emergency - weeks Best On Time Delivery Rate (99%+ in the last 3 months)* Highest Ampacity Ratings DNV: 95 C ABS: 00 C Lloyd s: 95 C Extremely Flexible *Visit for our most current on time delivery rate Instrumentation Cable Individually Shielded Pairs Individually Shielded Triads Multi-Conductor Control Cable...3- Power Cable...3- Single Conductor Two Conductor Three Conductor Four Conductor Five Conductor Type MMV Medium Voltage Power Cable..-9 Type VFD Power Cable Standard Gexol Insulated VFD Cable MMV VFD Cable AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listed is approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application. Gexol is a registered trademark of AmerCable Incorporated. Registered in the U.S. Patent and Trademark Office. 008 AmerCable Incorporated

3 Gexol Insulated are the industry s standard for premium power, control and instrumentation performance. Gexol cables prove their value daily in the punishing operating environments of offshore drilling and petroleum facilities around the world. Offshore applications challenge cable construction with relentless heat, vibration, salt corrosion, drilling mud and mechanical stress. And reliability is a huge issue because it s a long, long way to the nearest cable warehouse. You can depend on Gexol Insulated Oil & Gas cables for safe, reliable performance in the harshest operating conditions. Ampacity Ratings 0 C (Free Air) Ratings Based on IEEE Std for isolated cables in free air with full sun, ft/s air movement, and a 5 C ambient. 0 C Ratings Based on IEEE Std. 5 with a 5 C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 0 C ampacities should be multiplied by C Ratings Based on IEEE Std. 5 with a 5 C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 00 C ampacities should be multiplied by C Ratings Based on Table /3C.0 of the 997 ABS MODU rules and a 5 C ambient. Ampacities for four conductor cables are based on one conductor not acting as a normal current-carrying conductor (e.g., grounded neutral or grounding conductor). Bend Radius Unarmored Armored Armored & Sheathed IEEE 5 X Diameter 8X Diameter 8X Diameter IEC 9 <" (5mm) X Diameter 8X Diameter x Diameter >" (5mm) X Diameter Transport <" (5mm) X Diameter X Diameter Canada X Diameter >" (5mm) X Diameter Diameter Conversion (inches to millimeters): Multiply by 5. Hawke Gland Types Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone &

4 Gexol Insulated Power, Control and Instrumentation Cable Stranding Profile Individual Closest Equivalent Uninsulated Size Number Strand Dia. IEEE 5 Metric Size Conductor AWG/kcmil of Strands (inches) Std. Size (mm) Dia. (inches) /0 /0 3/0 / Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & Drilling Mud Resistant Oil Resistant v.08.

5 37-0 Single Conductor Power Cable Gexol Insulated Extremely Flexible 00V or kv Rated 0 C Conductor Soft annealed flexible stranded tinned copper per IEEE 580 Table. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. Insulation/Jacket GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA V/IEC 000V. Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Ratings & Approvals (Other certifications pending) Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). 0 C Temperature Rating Flame retardant: IEC 33-3 Category A and IEEE 0. NVE 95/9, FAL Suitable for use in Class I, Division and Zone Transport Canada environments (armored and sheathed). Det Norske Veritas (DNV) Optional braid armor of bronze or tinned copper. E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) American Bureau of Shipping (ABS) 99-BT5905-X UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) 00V Unarmored (kv on next page) Size Unarmored Inductive Voltage Drop DC Resistance AC Resistance at Ampacity AWG/ Part No. Diameter Weight Reactance at 0 C at 5 C 0 C, 0 Hz Free Air kcmil 37-0 (inches) (lbs/mft.) (Ohms/k ft.) (Volts/Amp/kft.) (Volts/Amp/kft.) (Ohms/k ft.) 0 C 0 C 00 C 95 C / / / v.08. www. amercable.com marine@amercable.com 3

6 37-0 Single Conductor Power Cable Gexol Insulated Extremely Flexible kv Rated 0 C kv Flexible Power Cable Single Conductor Armored and Unarmored Armored (B) Sheath (BS) Size Unarmored Diameter Nominal Nominal Inductive Voltage Drop DC Resistance AC Resistance at Ampacity AWG/ Part No. Diameter Weight Under Armor Weight Diameter Weight Diameter Weight Reactance at 0 C at 5 C 0 C, 0 Hz Free Air kcmil mm 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) (Ohms/000 ft.) (Volts/Amp/000 ft.) (Ohms/000 ft.) (Ohms/000 ft.) 0 C 0 C 00 C 95 C * * * * * * * * * * / * / * / * / BS Armor Requirement BS armored & sheathed Blank no armor Specific Cable Number (from charts) AmerCable Gexol Oil & Gas Prefix *Unarmored 3/0 and smaller has a jacket per UL309 & IEEE580 Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance Ordering Gexol Example: Single conductor power cable GEXOL kv 00% is a registered trademark of See page for Stranding Profile 535 kcmil AmerCable Incorporated bronze armored & sheathed Manufactured by AmerCable Incorporated Fax: West Little York Bldg. # Suite #00 Houston, TX 770 www. amercable.com v.08.

7 37-0 Two Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Insulation GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Color code: Black-White Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Ratings & Approvals (Other certifications pending) Conductor Soft annealed flexible stranded tinned copper per IEEE 580 Table. Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. 0 C Temperature Rating American Bureau of Shipping (ABS) 99-BT5905-X Transport Canada Det Norske Veritas (DNV) E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) NVE 95/9, FAL UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & v.08. www. amercable.com marine@amercable.com 5

8 37-0 Two Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Flexible Power Cable Two Conductor Armored and Unarmored Armored (B) Sheath (BS) Size Nominal Nominal Nominal AC Resistance Inductive Voltage Drop AWG/ Part No. Diameter Weight Diameter Weight Diameter Weight DC Resistance at 0 C, 0 Hz Reactance 0 C Ampacity kcmil mm 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) 5 C (Ohms/000 ft.) (Ohms/000 ft.) (Ohms /000 ft.) (Volts/Amp/000 ft.) 0 C 00 C 95 C / / Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance See page for Stranding Profile BS Armor Requirement BS armored & sheathed Blank no armor Specific Cable Number (from charts) AmerCable Gexol Oil & Gas Prefix Ordering Gexol Example: conductor power cable 0./kV # AWG bronze armored & sheathed GEXOL is a registered trademark of AmerCable Incorporated Manufactured by AmerCable Incorporated Fax: West Little York Bldg. # Suite #00 Houston, TX 770 www. amercable.com v.08.

9 37-0 Three Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Conductor Soft annealed flexible stranded tinned copper per IEEE 580 Table. Insulation GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Color code: Black-White-Red Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Ratings & Approvals (Other certifications pending) Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. An uninsulated ground conductor may be incorporated on a make-to-order basis. 0 C Temperature Rating American Bureau of Shipping (ABS) 99-BT5905-X Transport Canada Det Norske Veritas (DNV) E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) NVE 95/9, FAL UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & v.08. www. amercable.com marine@amercable.com 7

10 37-0 Three Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C 8 Flexible Power Cable Three Conductor Armored and Unarmored Armored (B) Sheath (BS) Size Nominal Nominal Nominal AC Resistance Inductive Voltage Drop Opt. Uninsulated AWG/ Part No. Diameter Weight Diameter Weight Diameter Weight DC Resistance at 0 C, 0 Hz Reactance 0 C Grounding Cond. Ampacity kcmil mm 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) 5 C (Ohms/000 ft.) (Ohms/000 ft.) (Ohms /000 ft.) (Volts/Amp/000 ft.) Size AWG 0 C 00 C 95 C / / / / BS G Ordering Gexol Example: 3 conductor power cable 0./kV bronze armored & sheathed with ground Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance Ground Conductor G with ground Blank no ground Armor Requirement BS armored & sheathed Blank no armor Specific Cable Number (from charts) AmerCable Gexol Oil & Gas Prefix See page for Stranding Profile GEXOL is a registered trademark of AmerCable Incorporated Manufactured by AmerCable Incorporated Fax: West Little York Bldg. # Suite #00 Houston, TX 770 www. amercable.com v.08.

11 37-0 Four Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Insulation GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Color code: Black-White-Red-Green Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Ratings & Approvals (Other certifications pending) Conductor Soft annealed flexible stranded tinned copper per IEEE 580 Table. Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. An uninsulated ground conductor may be incorporated on a make-to-order basis. 0 C Temperature Rating American Bureau of Shipping (ABS) 99-BT5905-X Transport Canada Det Norske Veritas (DNV) E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) NVE 95/9, FAL UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & v.08. www. amercable.com marine@amercable.com 9

12 37-0 Four Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C 0 Flexible Power Cable Four Conductor Armored and Unarmored Armored (B) Sheath (BS) Size Nominal Nominal Nominal AC Resistance Inductive Voltage Drop Opt. Uninsulated AWG/ Part No. Diameter Weight Diameter Weight Diameter Weight DC Resistance at 0 C, 0 Hz Reactance 0 C Grounding Cond. Ampacity kcmil mm 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) 5 C (Ohms/000 ft.) (Ohms/000 ft.) (Ohms /000 ft.) (Volts/Amp/000 ft.) Size AWG 0 C 00 C 95 C / / / / Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance BS G Ground Conductor G with ground Blank no ground Armor Requirement BS armored & sheathed Blank no armor Specific Cable Number (from charts) AmerCable Gexol Oil & Gas Prefix Ordering Gexol Example: conductor power cable 0./kV # AWG bronze armored & sheathed with ground See page for Stranding Profile GEXOL is a registered trademark of AmerCable Incorporated Manufactured by AmerCable Incorporated Fax: West Little York Bldg. # Suite #00 Houston, TX 770 www. amercable.com v.08.

13 37-0 Five Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table. Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. Ratings & Approvals (Other certifications pending) Insulation GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Color code: Black-White-Red- Green-Orange Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE C Temperature Rating American Bureau of Shipping (ABS) 99-BT5905-X Transport Canada Det Norske Veritas (DNV) E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) NVE 95/9, FAL UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & v.08. www. amercable.com marine@amercable.com

14 37-0 Five Conductor Power Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Flexible Power Cable Five Conductor Armored and Unarmored Armored (B) Sheath (BS) Size Nominal Nominal Nominal AC Resistance Inductive Voltage Drop AWG/ Part No. Diameter Weight Diameter Weight Diameter Weight DC Resistance at 0 C, 0 Hz Reactance 0 C Ampacity kcmil mm 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) 5 C (Ohms/000 ft.) (Ohms/000 ft.) (Ohms /000 ft.) (Volts/Amp/000 ft.) 0 C 00 C 95 C / / / Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance BS Armor Requirement BS armored & sheathed Blank no armor Specific Cable Number (from charts) AmerCable Gexol Oil & Gas Prefix Ordering Gexol Example: 5 conductor power cable 0./kV # AWG bronze armored & sheathed See page for Stranding Profile GEXOL is a registered trademark of AmerCable Incorporated Manufactured by AmerCable Incorporated Fax: West Little York Bldg. # Suite #00 Houston, TX 770 www. amercable.com v.08.

15 37-0 Multi-Conductor Control Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table. Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Color code: IEEE 580 Table Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Color code: IEEE 580 Table Ratings & Approvals (Other certifications pending) Insulation GEXOL cross-linked, flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. 0 C Temperature Rating American Bureau of Shipping (ABS) 99-BT5905-X Transport Canada Det Norske Veritas (DNV) E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) NVE 95/9, FAL UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division, and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & v.08. www. amercable.com marine@amercable.com 3

16 37-0 Multi-Conductor Control Cable Gexol Insulated Extremely Flexible 0./kV Rated 0 C Flexible Control Cable Multi-Conductor Armored and Unarmored Armored (B) Sheath (BS) Nominal Nominal Nominal Size Number of Part No. Diameter Weight Diameter Weight Diameter Weight Ampacity AWG Conductors 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) 0 C 00 C 95 C Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance See page for Stranding Profile Ordering Gexol Example: Multi-Conductor control cable 0./kV # AWG bronze armored & sheathed AmerCable Gexol Oil & Gas Prefix BS Specific Cable Number (from charts) Armor Requirement BS armored & sheathed Blank no armor GEXOL is a registered trademark of AmerCable Incorporated Manufactured by AmerCable Incorporated Fax: v.08.

17 37-0 Shielded Pairs Instrumentation Cable Gexol Insulated Extremely Flexible Individually Shielded Pairs 0./kV Rated 0 C v.08. Insulation GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Ratings & Approvals (Other certifications pending) Conductor Soft annealed flexible stranded tinned copper per IEEE 580 Table. Pairs Each pair is twisted with a bare tinned drain wire. Each pair is shielded with polyester-backed aluminum foil tape to afford 00% coverage. Pair to pair isolation plus overall shield is provided. Pair color code: Black-White Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Cable available with blue jacket or stripe to signify intrinsically safe circuit. 0 C Temperature Rating American Bureau of Shipping (ABS) 99-BT5905-X Transport Canada Det Norske Veritas (DNV) E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) NVE 95/9, FAL UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) GEXOL is a registered trademark of AmerCable Incorporated www. amercable.com marine@amercable.com Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & 5

18 37-0 Shielded Pairs Instrumentation Cable Gexol Insulated Extremely Flexible Individually Shielded Pairs 0./kV Rated 0 C Flexible Instrumentation Cable Individually Shielded Pairs #8 Pairs Capacitance (nf/000 feet) = 8 Inductance (mh/000) = 0. Resistance (Ohms/000 feet) = 7. (@ 0 C) Armored and Unarmored Armored (B) Sheath (BS) Nominal Nominal Nominal Size Number of Part No. Diameter Weight Diameter Weight Diameter Weight AWG Pairs 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance VALUES: # Pairs Capacitance (nf/000 feet) = 3 Inductance (mh/000) = 0.0 Resistance (Ohms/000 feet) =.5 (@ 0 C) See page for Stranding Profile # Pairs Capacitance (nf/000 feet) = 37 Inductance (mh/000) = 0.9 Resistance (Ohms/000 feet) =.85 (@ 0 C) GEXOL is a registered trademark of AmerCable Incorporated Ordering Gexol Example: Instrumentation cable 0./kV # AWG bronze armored & sheathed AmerCable Gexol Oil & Gas Prefix BS Specific Cable Number (from charts) Armor Requirement BS armored & sheathed Blank no armor Manufactured by AmerCable Incorporated Fax: v.08.

19 37-0 Shielded Triads Instrumentation Cable Gexol Insulated Extremely Flexible Individually Shielded Triads 0./kV Rated 0 C Insulation GEXOL cross-linked, flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Ratings & Approvals (Other certifications pending) Conductor Soft annealed flexible stranded tinned copper per IEEE 580 Table. Triads Each triad is twisted with a bare tinned drain wire. Each triad is shielded with polyester-backed aluminum foil tape to afford 00% coverage. Triad to triad isolation plus overall shielding is provided. Triad color code: Black-White-Red Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Cable available with blue jacket or stripe to signify intrinsically safe circuit. 0 C Temperature Rating American Bureau of Shipping (ABS) 99-BT5905-X Transport Canada Det Norske Veritas (DNV) E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS) 9/0333 (E) NVE 95/9, FAL UL Listed as Marine Shipboard Cable (E) United States Coast Guard November, 987 / 930 CSA listed as Marine Shipboard Cable (83) Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world. Features High strand count conductors make this product much more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Gexol s lower dielectric constant and higher insulation resistance reduces electrical losses. Gexol s excellent resistance to moisture produces stable electrical properties throughout the life of the cable. In a fire condition, Gexol s nonchlorinated flame retardant system produces less toxic and less corrosive gases. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division, and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & v.08. www. amercable.com marine@amercable.com 7

20 37-0 Shielded Triads Instrumentation Cable Gexol Insulated Extremely Flexible Individually Shielded Triads 0./kV Rated 0 C Flexible Instrumentation Cable Individually Shielded Triads Armored and Unarmored Armored (B) Sheath (BS) Nominal Nominal Nominal Size Number of Part No. Diameter Weight Diameter Weight Diameter Weight AWG Triads 37-0 (inches) (lbs/mft.) (inches) (lbs/mft.) (inches) (lbs/mft.) Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance See page for Stranding Profile VALUES: #8 Triads Capacitance (nf/000 feet) = 8 Inductance (mh/000) = 0. Resistance (Ohms/000 feet) = 7. (@ 0 C) # Triads Capacitance (nf/000 feet) = 3 Inductance (mh/000) = 0.0 Resistance (Ohms/000 feet) =.5 (@ 0 C) Ordering Gexol Example: Instrumentation cable 0./kV #8 AWG bronze armored & sheathed AmerCable Gexol Oil & Gas Prefix BS Specific Cable Number (from charts) Armor Requirement BS armored & sheathed Blank no armor 8 GEXOL is a registered trademark of AmerCable Incorporated Manufactured by AmerCable Incorporated Fax: v.08.

21 37-0VFD Type VFD Power Cable Gexol Insulated Three Conductor kv Rated 0 C Power Conductors (x3) Soft annealed flexible stranded tinned copper per IEEE 580 Table. Insulation (kv) Gexol cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 580 and Type X0 of UL 309/CSA 5. Color: Gray with printed phase I.D. (Black-White-Red) Armor (Optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. Termination Kits AmerCable Systems offers pre-sized and pre-formed termination kit packages specifically for VFD cable constructions Gexol insulation has low capacitance for superior performance in VFD applications! Ratings & Approvals (Other certifications pending) Ground Conductors (x3) Soft annealed flexible stranded tinned copper per IEEE 580 Table. Gexol insulation sized per UL 77. Color: Green Shield Overall tinned copper braid plus aluminum/ polyester tape providing 00% coverage. Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE 580. Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5 and IEEE C Temperature Rating American Bureau of Shipping (ABS): 99-BT5905-X Transport Canada: Det Norske Veritas (DNV): E-9, E-388, E-390, E-39 Lloyd s Register of Shipping (LRS): 9/0333 (E) NVE: 95/9, FAL UL Listed as Marine Shipboard Cable: (E) UL Listed as Type TC (E39) available by request United States Coast Guard: November, 987 / 930 CSA listed as Marine Shipboard Cable (83) Application A flexible, braid and foil shielded, kv power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications. Features Specially engineered cable design produces a longer cable life in VFD applications. Overall braid and foil shield provides 00% coverage containing VFD EMI emissions. Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. Gexol s lower dielectric constant (standard XLPEs, EPRs and other Type P insulation materials have higher dielectric constants) reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. kv insulation thickness resists the repetitive x voltage spikes from 00V VFDs and reduces drive over current trip problems due to cable charging current. Dual certified IEEE 580 Type P and UL 309/CSA 5 Type X0. Highest ampacity ratings: ABS 00 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division and Zone environments (armored and sheathed). Optional braid armor of bronze or tinned copper. v.0. www. amercable.com marine@amercable.com 9

22 37-0VFD Type VFD Power Cable Gexol Insulated Three Conductor kv Rated 0 C Unarmored Armored Armored & Sheathed (BS) Green Insulated Size Nominal Weight Nominal Weight Nominal Weight Grounding Ampacity AWG/ Part No. Diameter Per Part No. Diameter Per Part No. Diameter Per Conductor (x3) kcmil 37-0 Inches* 000 Ft Inches* 000 Ft Inches* 000 Ft. Size (AWG) 0 C 00 C 95 C 90 C 75 C -508VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD.5 0-3BSVFD VFD.5-3BVFD.7 8-3BSVFD VFD BVFD BSVFD /0-3VFD BVFD BSVFD /0-37VFD BVFD BSVFD /0-39VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD VFD BVFD BSVFD *Cable diameters are subject to a +/- 5% manufacturing tolerance See page for Stranding Profile and has a low capacitance for superior performance in VFD applications! GEXOL is a registered trademark of AmerCable Incorporated Gexol is flexible VFD Cable Ampacity Ratings 0 C Ratings Based on IEEE Std. 5 with a 5 C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 0 C ampacities should be multiplied by C Ratings Based on IEEE Std. 5 with a 5 C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 00 C ampacities should be multiplied by C Ratings Based on -3-/Table 0 of the 00 ABS MODU rules and a 5 C ambient. 90 C Ratings Based on ICEA S Table H- for a single isolated cable in air with a 0 C ambient. This ampacity is typically used for mining and other portable applications. 75 C Ratings Based on Table B.30. of the 005 NEC for cables in raceway and a 30 C ambient. 0 Manufactured by AmerCable Incorporated Fax: v.0.

23 37-05 Type MMV Medium Power Cable Single Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table. Insulation Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR), meeting UL 309 (Type E), IEEE 580 (Type E), ICEA S-8-5 and UL 07. Metallic Shield Composite shield consisting of 0.0" tinned copper braided with nylon providing 0% copper Shielded coverage meeting UL 309, IEEE Std. 580, ICEA S-8-5 and UL 07. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 309, IEEE 580, ICEA S-8-5 and UL07. Insulation Shield Semi-conducting tape, with overlap, for fast and easy termination meeting UL 309, IEEE 580, ICEA S-8-5 and UL 07. Grounding Conductor (optional) One uninsulated soft annealed flexible stranded tinned copper conductor per ASTM B 33 and sized according to Table. of UL 07. Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309, IEEE 580, ICEA S-8-5 and UL 07. Colored jackets for signifying different voltage levels are also available on special request (ie. yellow = 5kV, orange = 8kV and red = 5kV). Armor (optional) (Optional) 0.0" bronze braid providing 88% minimum coverage meeting UL 309 and IEEE Std Sheath (optional) A black, arctic grade, flame retardant, oil, abrasion, chemical, and sunlight resistant thermosetting compound meeting UL 309, IEEE 580, ICEA S-8-5 and UL 07. Colored jackets for signifying different voltage levels is also available on special request (ie. yellow = 5kV, orange = 8kv and red = 5kV). Ratings & Approvals UL Listed as Marine Shipboard Cable (E) American Bureau of Shipping (ABS) Det Norske Veritas (DNV) Pending Lloyd s Register of Shipping (LRS) Pending 90 C Temperature Rating Voltage Rating 5kV to 5kV (5kV available on request) Termination Kits AmerCable recommends Raychem s HVT series terminations for single conductor constructions and HVT-M series terminations for multi-conductor constructions. Applications AmerCable s Type MMV marine medium voltage cables are for use aboard commercial ships, mobile offshore drilling units (MODUs), and fixed or floating offshore facilities. Features These cables utilize flexible stranded conductors, braided shields and a braided armor (when armored) which make them very suitable for applications involving repeated flexing and high vibration. These cables have a small minimum bending radius (xod for unarmored cables and 8xOD for armored cables) for easy installation. Optional uninsulated grounding conductors sized per UL 07. The increased flexibility of this cable allows for termination of one end and coiling on multiple module offshore platforms. Then coiling and terminating other end when modules are mated at sea thereby reducing installation time. Passes IEC 33-3 Category A and IEEE 0 flame tests. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) 53-X Increased Safety EExe 50/ 50/53/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof 50/ 50/53/U EExd Zone & ( liter or < enclosures) ICG 53/U ( liter or > enclosures) Zone & v.08. www. amercable.com marine@amercable.com

24 37-05 Type MMV Medium Voltage Cable Single Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Unarmored Armored & Sheathed (BS) Ampacity Inductive Voltage Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm (inches) 000 ft.) 000 ft.) 000 ft.) (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 8 /0 /0 3/0 / Single Conductor Type MMV Marine Medium Voltage 5kV, 00/33% Insulation Level Inductive Voltage Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm (inches) 000 ft.) 000 ft.) 000 ft.) (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 3/0 / Single Conductor Type MMV Marine Medium Voltage 8kV, 00% Insulation Level Unarmored Armored & Sheathed (BS) Ampacity See page 7 for MMV Stranding Profile Manufactured by AmerCable Incorporated Fax: v.08.

25 37-05 Type MMV Medium Voltage Cable Single Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Single Conductor Type MMV Marine Medium Voltage 8kV, 33% Insulation Level Inductive Voltage Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm (inches) 000 ft.) 000 ft.) 000 ft.) (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 3/0 / Unarmored Armored & Sheathed (BS) Ampacity Single Conductor Type MMV Marine Medium Voltage 5kV, 00% Insulation Level Inductive Voltage Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm (inches) 000 ft.) 000 ft.) 000 ft.) (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 3/0 / Unarmored Armored & Sheathed (BS) Ampacity See page 7 for MMV Stranding Profile v.08. Ordering Type MMV Medium Voltage Cables Example: 3 conductor power cable AmerCable Type 8kV 00% MMV Prefix # AWG ground bronze armored & sheathed BS G Specific Cable Number (from charts) Armor Requirement BS armored & sheathed Blank no armor Ground Conductor G with ground Blank no ground www. amercable.com marine@amercable.com 3

26 37-05 Type MMV Medium Voltage Cable Single Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Single Conductor Type MMV Marine Medium Voltage 5kV, 33% Insulation Level Unarmored Armored & Sheathed (BS) Ampacity Inductive Voltage Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm (inches) 000 ft.) 000 ft.) 000 ft.) (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 3/0 / Three Conductor Type MMV Marine Medium Voltage 5kV, 00/33% Insulation Level Single Inductive Size Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm (inches) 000 ft.) (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor 8 /0 /0 3/0 / Unarmored Armored & Sheathed (BS) Ampacity / See page 7 for MMV Stranding Profile Manufactured by AmerCable Incorporated Fax: v.08.

27 37-05 Type MMV Medium Voltage Cable Single Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Three Conductor Type MMV Marine Medium Voltage 8kV, 00% Insulation Level Single Inductive Size Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm (inches) 000 ft.) (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 3/0 / Single Inductive Size Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm (inches) 000 ft.) (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 3/0 / Unarmored Three Conductor Type MMV Marine Medium Voltage 8kV, 33% Insulation Level Unarmored Armored & Sheathed (BS) Armored & Sheathed (BS) Ampacity Ampacity /0 See page 7 for MMV Stranding Profile Ordering Type MMV Medium Voltage Cables Example: 3 conductor power cable AmerCable Type 8kV 00% MMV Prefix # AWG ground bronze armored & sheathed BS G Specific Cable Number (from charts) Armor Requirement BS armored & sheathed Blank no armor Ground Conductor G with ground Blank no ground v.08. www. amercable.com marine@amercable.com 5

28 37-05 Type MMV Medium Voltage Cable Single Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Three Conductor Type MMV Marine Medium Voltage 5kV, 00% Insulation Level Unarmored Armored & Sheathed (BS) Ampacity Single Inductive Size Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm (inches) 000 ft.) (inches 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 3/0 / Single Inductive Size Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm (inches) 000 ft.) (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 3/0 / Three Conductor Type MMV Marine Medium Voltage 5kV, 33% Insulation Level Unarmored Armored & Sheathed (BS) Ampacity See page 7 for MMV Stranding Profile Ordering Type MMV Medium Voltage Cables Example: 3 conductor power cable AmerCable Type 8kV 00% MMV Prefix # AWG ground bronze armored & sheathed BS G Specific Cable Number (from charts) Armor Requirement BS armored & sheathed Blank no armor Ground Conductor G with ground Blank no ground Manufactured by AmerCable Incorporated Fax: v.08.

29 37-05VFD Type MMV-VFD Power Cable Three Conductor: 8kV 5kV 33% Insulation Level Rated 90 C Conductors (3) Soft annealed flexible stranded tinned copper per IEEE 580 Table. Insulation Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR), meeting UL 309 (Type E), IEEE 580 (Type E), ICEA S-8-5 and UL 07. EMI Shield Overall tinned copper braid plus aluminum/ polyester tape providing 00% coverage Insulation Shield Composite shield consisting of 0.0" tinned copper braided with nylon providing 0% copper Shielded coverage meeting UL 309, IEEE Std. 580, ICEA S-8-5 and UL 07. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Termination Kits AmerCable Systems offers pre-sized and pre-formed termination kit packages specifically for VFD cable constructions Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 309, IEEE 580, ICEA S-8-5 and UL07. Insulation Shield Semi-conducting layer meeting UL 309, IEEE 580, ICEA S-8-5 and UL 07. Symmetrical Insulated Grounding Conductors (3) Soft annealed flexible stranded tinned copper conductor per IEEE 580 Table. Gexol Insulation sized per Table 3. of UL07. Color: Green Jacket A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5, IEEE 580, and UL 07. Colored jackets for signifying different voltage levels are also available on special request (orange = 8kV and red = 5kV). Armor (optional) Basket weave wire armor per IEEE 580 and UL 309/CSA 5. Bronze standard. Tinned copper available by request. Sheath (optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 309/CSA 5, IEEE 580, and UL 07. Colored jackets for signifying different voltage levels are also available on special request (orange = 8kV and red = 5kV). Low smoke halogen-free jacket available on request. Ratings & Approvals UL Listed as Marine Shipboard Cable (E) American Bureau of Shipping (ABS) Det Norske Veritas (DNV) Pending Lloyd s Register of Shipping (LRS) Pending 90 C Temperature Rating Voltage Rating 8kV to 5kV (5kV available on request) Applications A flexible, braid and foil shielded, power cable specifically engineered for use in medium voltage variable frequency AC drive (VFD) applications. Features Flexible stranded conductors, braided shields and a braided armor (when armored). Suitable for applications involving repeated flexing and high vibration. Small minimum bending radius (xod for unarmored cables and 8xOD for armored cables) for easy installation. Insulation resists the repetitive 3x voltage spikes from VFDs and reduces drive over current trip problems due to cable charging current. Overall braid and foil shield provides 00% coverage containing VFD EMI emissions. Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). Flame retardant: IEC 33-3 Category A and IEEE 0. Suitable for use in Class I, Division and Zone environments (armored and sheathed). v.08. www. amercable.com marine@amercable.com 7

30 37-05VFD Type MMV-VFD Power Cable Three Conductor: 8kV 5kV 33% Insulation Level Rated 90 C Three Conductor Type MMV-VFD Marine Medium Voltage 8kV 33% Insulation Level Unarmored Armored & Sheathed (BS) Ampacity Single Inductive Voltage Green Insulated Size Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding AWG/ Part No. Diameter (Lbs./ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Conductor (3x) kcmil mm (inches) 000 ft.) (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Size (AWG) /0 /0 3/0 / VFD -333VFD -33VFD -335VFD -33VFD -337VFD -338VFD -339VFD -30VFD -3VFD -3VFD -33VFD -3VFD BSVFD -333BSVFD -33BSVFD -335BSVFD -33BSVFD -337BSVFD -338BSVFD -339BSVFD -30BSVFD -3BSVFD -3BSVFD -33BSVFD -3BSVFD Three Conductor Type MMV-VFD Marine Medium Voltage 5kV 33% Insulation Level Single Inductive Voltage Green Insulated Size Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding AWG/ Part No. Diameter (Lbs./ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Conductor (3x) kcmil mm (inches) 000 ft.) (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Size (AWG) /0 /0 3/0 / VFD -358VFD -359VFD -30VFD -3VFD -3VFD -33VFD -3VFD -35VFD -3VFD Unarmored BSVFD -358BSVFD -359BSVFD -30BSVFD -3BSVFD -3BSVFD -33BSVFD -3BSVFD -35BSVFD -3BSVFD Armored & Sheathed (BS) Ampacity Ordering Type MMV-VFD Medium Voltage Cables Example: 3 conductor MMV-VFD power cable 8kV # AWG Unarmored AmerCable Type MMV-VFD Prefix VFD Specific Cable Number (from charts) Ordering Type MMV-VFD Medium Voltage Cables Example: 3 conductor MMV-VFD power cable 5kV # AWG bronze armored & sheathed AmerCable Type MMV-VFD Prefix BSVFD Specific Cable Number (from charts) 8 Manufactured by AmerCable, Incorporated (870) 8-99 (800) 3-5 Fax (870) 8-93

31 37-05 Type MMV Medium Voltage Cable Single Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & 33% Insulation Levels. Rated 90 C Individual Closest Equivalent Uninsulated Size Number Strand Dia. IEEE 5 Metric Size Conductor AWG/kcmil of Strands (inches) Std. Size (mm) Dia. (inches) 8 /0 /0 3/0 / MMV Stranding Profile MMV Ampacities & Electrical Data Ampacities are based on API RP F (June 999) Table or 5 for single conductor cables and Table 3 for multi-conductor cables. The notes to these tables are also applicable. Ampacities are also based on a 90 C conductor temperature and a 5 C ambient temperature. Inductive reactance and voltage drop values are based on a 90 C conductor temperature and 0 Hz operation. Values for single conductor cables are based on a symmetrical triangular configuration. Please consult AmerCable on values for other configurations. MMV Bend Radius Unarmored Armored Armored & Sheathed IEEE 5 X Diameter 8X Diameter 8X Diameter IEC 9 <" (5mm) X Diameter 8X Diameter x Diameter >" (5mm) X Diameter Transport <" (5mm) X Diameter X Diameter Canada X Diameter >" (5mm) X Diameter v.08. www. amercable.com marine@amercable.com 9

32 Ester Based Mud Resistant Jacketed Cables 0 C UL Marine Shipboard Cable Designed to deliver outstanding performance in the harshest operating conditions specifically in high temperature Ester Based drilling muds. A swollen or split cable jacket due to drilling mud exposure is a productivity killer. AmerCable offers three levels of mud resistance to match your operating conditions: Standard, Advanced and Ester Based Mud Resistant 30

33 Ester Based Mud Resistant Jacketed Cables 0 C UL Marine Shipboard Cable When standard mud resistance isn t enough, AmerCable has a World Class Mud Resistant cable jacket designed to deliver outstanding performance in the harshest operating conditions. Designed specifically for exposure to high temperature ESTER BASED drilling muds, this cable meets all the performance requirements of industry standards UL 309 and IEEE 580 for Type N jackets. When tested for prolonged exposure to the most aggressive ester based drilling muds, it easily passes the mud resistance requirements of NEK 0. Table I World Class Mud Resistant Jacket Physical Requirements Unaged Aging Requirements 90 C Rated Jacket ± C Air Oven 0 Hours Oil Exposure Resistance After Oil Immersion at ± C 8 Hours Mechanical Water Absorption Weatherometer Test Specifications Jacket Type Type N Type N Mud Resistant Jacket Tensile Strength, Min, PSI Pass Elongation at Rupture, Min, % Pass Set, Max, % 0 0 Pass Tensile Strength, Minimum 900 psi 900 psi Pass Elongation at Rupture, % Tensile Strength, % Retention of Unaged, Min Elongation at Rupture, % Retention of Unaged, Min mg / in Per UL 58 AmerCable s ester based mud resistant cables were also tested against the requirements of UL 309 and IEEE 580 and the results are shown in Table I. This product easily passed all the requirements. Table II shows the results of this cable when aged in Baroid Petrofree (Ester Based) drilling mud per NEK 0. All aging requirements were met. Additional testing done on these cables show the jacket to pass cold impact at -0 C and cold bend at -0 C. UL-309 Table 50% Actual 50% Actual Pass Pass 0 0 Pass Pass No Requirement IEEE 580 Table 5-7 Pass AmerCable Testing Program Pass Tear FT/IEEE 0 Flame Exposure (UL-85) IEC 33-3 Flame Exposure lb/in Thickness, Min No Requirement 35 Pass Pass Pass Pass No Requirement No Requirement Pass Table II MUD Resistant NEK 0 Note: Tested for Changes in Each Listed Requirement 70 C, 5 Days Requirements Mud Type Results Elongation at Break ±5% Baroid Petrofree (Ester Based) Pass Tensile Strength ±5% Baroid Petrofree (Ester Based) Pass Volume Swelling Max 0% Baroid Petrofree (Ester Based) Pass Weight Increase Max 5% Baroid Petrofree (Ester Based) Pass Oxygen Index Min 5% Baroid Petrofree (Ester Based) Pass All results representative of finished cables ( 3/C, 7/C and 8 7 PR). Test data on file at AmerCable v.08. www. amercable.com marine@amercable.com 3

34 Precision Engineered Cable ASSEMBLIES Constructions: 300V 5kV AC DC Power Composite Power & Control Instrumentation Thermocouple Fiber Optic Electro-Optic Applications: Service Loops Driller s Console Mud Pump Controls 5kV Bridle Assembly Tender-to-Platform Bridle Ship-to-Shore Power Portable Power Generation Zone (EX) Rated Cable Assemblies Turn-key cable assembly solutions for hazardous and industrial environments The Assembly Application Professionals 3

35 Fast Delivery Job-site application evaluation and consultation Highly reliable cable assemblies custom built and tested to spec (800) Ask About Our TOP DRIVE SERVICE LOOPS Cable Assemblies from AmerCable Systems save you time & money!

36 AmerCable is an ISO 900 certified cable manufacturer that combines leading-edge manufacturing technology, innovative thinking, and high quality service to deliver the finest oil & gas cable and engineered cable assemblies available. AmerCable serves the world from our Oil & Gas Group headquarters in Houston, Texas. Our professional field engineers and sales force work with you to create innovative, cost-effective project solutions. AmerCable s manufacturing facility in El Dorado, Arkansas. What can you expect from AmerCable? Fastest Lead Times in the Industry (Standard 8-0 weeks / Emergency - weeks) On-Time Delivery (99% avg. for the last 3 months) Professional Sales, Support and Service Global Cable Management Low smoke halogen-free fire resistant or flame retardant Type P cables. Precision engineered cable assemblies for hazardous and industrial applications. Crush and Impact Resistant Type P cables without external armoring. Premiumlevel high performance IEC cables Meets BOTH IEC and IEEE marine shipboard cable standards. VFD CABLES Foil shielded, power cables engineered for use in variable frequency AC drive applications. Available in several constructions 033 West Little York Building # Suite #00 Houston, TX Fax: marine@amercable.com 008, AmerCable Incorporated /08

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable

More information

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

TUNNELING POWER CABLES

TUNNELING POWER CABLES TUNNELING POWER CABLES Index 3- Type G-GC (Round) 3/C kv..................... -3 3-5 Type SHD-GC 3/C 5kV........................ -5 3-55 Type SHD-GC 3/C 5kV........................ - 3-0/0/0 Type MP-GC

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

Automotive Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

Marine Wire and Cable

Marine Wire and Cable Marine Wire and Cable Low Smoke Zero Halogen Type T/N Type P Power/Distribution Cable Control Cable Signal & Instrumentation ICW Cord Building Wire Banding Tools and Accessories We re Partners With the

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

IEEE 1580 TYPE T/N CABLE

IEEE 1580 TYPE T/N CABLE 1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES 37- TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 000 VOLTS FEATURES Highly durable, abrasion-resistant CPE jacket specially designed

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS

VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS VFD Lean TR VFD Dual TR Servo VFD Combo DS VFD XLPE TR VFD XLPE 2KV TR SAB s VFD cable series has you covered from fractional to 2 HP drives suitable for industrial

More information

Electronic Instrumentation

Electronic Instrumentation Applications Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and

More information

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable SERVING THE NUCLEAR POWER MARKETS power generating plants original equipment manufacturer storage and waste management facilities

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

THE RIGHT SOLUTION FOR EVERY APPLICATION

THE RIGHT SOLUTION FOR EVERY APPLICATION VFD ABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLIATION Products Added VFD Lean TR VFD Dual TR Servo VFD ombo DS VFD XLPE TR VFD XLPE 2KV TR Also Included! FLEXIBLE ONTROL ONTINUOUS FLEX SILIONE

More information

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE Marine Cables FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for over 165 years, always dedicated to connecting

More information

Okoguard -Okoseal Type IEC

Okoguard -Okoseal Type IEC COMPACT STRAND CONSTRUCTION A B C D E F G H Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded Semiconducting EPR Phase

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

BFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency

More information

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES FOREWORD General Cable is a World leader in cable manufacturing with 38 modern production facilities in North America, Europe and Oceania, employing more than 10,000 people throughout

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored Variable Frequency

More information

FISCHER FREEDOM TM SERIES

FISCHER FREEDOM TM SERIES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE PRODUCTS COMMERCIAL BUILDING WIRE & CABLE Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored

More information

Standardization IEC /-351/-353. Conductor material

Standardization IEC /-351/-353. Conductor material Low voltage power cables Fire resistant low voltage power cables according to the new demanding IEC -60331 1/2 specifications for power and lighting applications in all ship areas, with reduced diameter

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)... MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9

More information

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE CABLE SOLUTIONS to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE GENERAL CABLE DELIVERS Advanced Reliability, Safety And Sustainability To The Nuclear Power Industry Safe,

More information

RFOU 0.6/1kV Power Cable

RFOU 0.6/1kV Power Cable RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, PP insulation, PVC jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color coded by

More information

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively

More information

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET UL TYPE PLTC UL AWM STYLE 20237 CSA AWM IA/B IIA/B FT1 76 CHOOSE XTRA GUARD 4 FOR: Three Times the Low-Temperature

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60 4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)

More information

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB Electrical temperature measurement For the plastics machinery industry Adjustable bayonet Model TC47-AB WIKA data sheet TE 67.20 Applications Plastics and rubber industry For direct installation into the

More information

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation

More information

CF270.UL.D.

CF270.UL.D. Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

Cable Glands - American Series - NEC/IEC

Cable Glands - American Series - NEC/IEC Cable Glands - 103 American Series - NEC/IEC 104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES SUBMERSIBLE PUMP CABLES GENERAL INTRODUCTION Bahra Cables Company was established in 2008 to serve Saudi & GCC Markets. It is based in Bahra industrial city located 25km from Jeddah. Bahra Cables Factory

More information

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition Loadbreak Connector CA650099EN Supersedes 500-28-7C November 2011 COOPER POWER SERIES 200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition General Eaton

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme. EcoSystem Cable 369385c 1 01.22.2018 Custom designed cable, for use with EcoSystem components, improves system performance and decreases installation time. Cable is available for sensor connections and

More information

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition Loadbreak Connectors CA650101EN Supersedes 500-29-7C November 2011 COOPER POWER SERIES 200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

More information

Loadbreak Apparatus Connectors

Loadbreak Apparatus Connectors Loadbreak Apparatus Connectors 200 A 25 kv Class POSI-BREAK Loadbreak Elbow Connector with Optional Integral Jacket Seal* Electrical Apparatus 500-29-7 general The POSI-BREAK Loadbreak Elbow Connector

More information

For the plastics machinery industry Manifold thermocouple Model TC47-MT

For the plastics machinery industry Manifold thermocouple Model TC47-MT Electrical temperature measurement For the plastics machinery industry Manifold Model TC47-MT WIKA data sheet TE 67.21 Applications Plastics and rubber industry Hot runner manifolds for injection mould

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series 3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series Data Sheet 1. Product Description 3M Cold Shrink Termination Kit QT-III 7672-S-8 Series contains one silicone rubber termination

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 310 310.120 CHANGES FROM 2011 TO 2014 CODE ARE IN RED ARTICLE 310 Conductors for General Wiring I. General 310.2 Definitions Electrical Ducts Electrical conduits, or other

More information

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable. ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, Flamarrest insulation and jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

Rail & Transit WIRE AND CABLE

Rail & Transit WIRE AND CABLE Rail & Transit WIRE AND CABLE OCTOBER 2014 TRANSIT Servicing the Rail & Transit Markets This catalog contains in-depth information on the most comprehensive line of rail & transit wire and cable available

More information

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Medium Voltage Cables for PermaLife Nuclear Utility Applications Medium Voltage Cables for PermaLife Nuclear Utility Applications The science behind our medium voltage cables. Fig. 1 Fig. 2 non-conducting stress control layer 100% production tested in accordance with

More information