1 Marine Wire and Cable Low Smoke Zero Halogen Type T/N Type P Power/Distribution Cable Control Cable Signal & Instrumentation ICW Cord Building Wire Banding Tools and Accessories

2 We re Partners With the Biggest Names in Marine Electrical We Serve the Marine, Offshore and Shipbuilding Markets Electric Supply stocks a complete product offering for our marine, offshore, and shipbuilding partners. is your one-stop supplier for marine applications in addition to a full range of products for the electrical professional, including distribution equipment, motor control, lamps and lighting, wiring devices, conduit and fittings, wire and cable, tools, automation, datacom and more. Stay in Touch with! Sign up to receive information on promotions and events or subscribe to our NewsWire, at Follow us for updates and industry news at twitter.com/summit_electric Check out the latest handy mobile apps for electricians Don t miss a single catalog! Sign up to make sure you continue to receive updated catalogs at summit.com/catalogs. Marine Division

3 Table of Contents Low Smoke Zero Halogen M2X Single Insulated Conductor Cable... 3 M2XH Power and Control Cable... 3 M2XCH Power and Control Cable, Shielded... 4 FM2XAH Overall Shielded Instrumentation Cable... 5 FM2XAAH, Individual and Overall Shielded Instrumentation Cable... 5 Type T/N Power/Distribution Cable (600/1000 Volts) Unarmored... 6 Aluminum Armored... 8 Bronze Armored Control Cable (600/1000 Volts) Unarmored, Multi-Conductor Aluminum Armored, Multi-Conductor Bronze Armored, Multi-Conductor Signal & Instrumentation, Pairs (600/1000 Volts) IS/OS Shielded Cable, Unarmored, Multi-Conductor IS/OS Shielded Cable, Aluminum Armored, Multi-Conductor IS/OS Shielded Cable, Bronze Armored, Multi-Conductor Type P Power/Distribution Cable 2kV XLPO/CP, 600/1000 Volts Control Cable 600 Volts Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, /1000 Volts Banding Banding Tools and Supplies Building Wire THHN/THWN/THWN-2, Copper Conductor, XHHW/XHHW-2, Copper Conductor RHH/RHW/USE, Copper Conductors Underground Feeder Cable, Copper Conductors w/ground Cord SJEOOW, 300 Volts SJOOW, 300 Volts SOOW, 600 Volts SEOOW, 600 Volts Bus Drop Cable Hook-Up Wire, MTW/TEW or AWM Welding Cable, Single Copper Conductor Diesel Locomotive, Single Copper Conductor, 2kV Type G & G-GC Round Power Cable w/ground, 2kV Type W Portable Power Cable, 2kV Extension Cord Impervious Continuously Welded (ICW) ICW Armored Instrumentation Cable, Individual and Overall Shielded, 600 Volts ICW Armored Power and Control Cable, 600 Volts ICW Armored Power Cable, Unshielded, 2.4kV ICW Armored Power Cable,Unshielded, 5kV 133% / 8kV 100% Insulation Level, Shielded ICW Armored Power Cable, Shielded, 15kV Connectors and Terminals Type YA-L One-Hole Lugs Cord Grips and Connectors Tools and Accessories Cutting Pliers Cable Cutters Crimping and Stripping Tools Reference Material Low Smoke Zero Halogen Selection Guide Low Smoke Zero Halogen Terminal Selection Guide Low Smoke Zero Halogen Gland Selection Guide Marine Cable Ampacity Guides Certifying Bodies

4 Selection, Service and Savings. Electric Supply offers a wide selection of industrial marine products, including wire and cable. Our services include in-house custom cable braiding, sourcing of hard-to-find specialty cable, and reliable shipment throughout the nation and around the world. Calling for your marine wire and cable ensures you will receive the best overall value, saving both time and money. Proven Industry Leader Since 1977, has been a supplier of choice for electrical professionals in the construction, MRO, OEM and industrial marine industries. With domestic and international operations, is ranked as one of the top 25 electrical distributors in the nation, based on sales. Focus on Marine and Offshore s marine division is dedicated to serving the needs of shipbuilders, shipyards and offshore rigs. Whether your project involves the construction, maintenance or repair of offshore vessels, offshore drilling rigs or inland vessels, you ll be pleased not only with our product lines, but also with our in-house cable braiding services. Our Inventory Our inventory policies are driven by our customer service commitment. Choose from our broad selection of marine products, including marine electrical distribution equipment and motor control gear, marine cable, marine lighting and navigation lighting. We offer products that meet most national and international certifications, including American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, and U.S. Coast Guard standards. Our People s commitment to training associates at all levels mean you ll find knowledgable people who offer fast, accurate technical and application support. Our experienced people understand your needs and can make recommendations that streamline your procurement process. Our Service offers local service with a global reach. Through our Middle East, Latin American and international operations, we supply projects across the country and around the world. Call or marine@summit.com for technical support or to place an order. The product and manufacturer names contained in this catalog are property of their respective owners. All rights apply. Every effort has been made to ensure the accuracy of the contents of this catalog. In the case of a suspected error, please contact the service center nearest you. Images in this catalog may be representative of a product category and not necessarily of a specific item. This catalog contains product information for both stock and non-stock items, based on local inventories. Please contact your local service center for pricing and availability. This catalog displays a broad, but not complete, sample of our product offering. For information about products not seen in this catalog, please contact your local service center. Many product categories are available from multiple manufacturers. As such, manufacturing specifications may vary. For critical specification information, please contact your local service center. Minimum order quantities may apply. Various packing sizes and put-up lengths may be available. Please contact your local service center for details. Electric Supply Marine Wire and Cable Catalog. (MWC12) 2012 Electric Supply, all rights reserved.

5 Low Smoke Zero Halogen Power and Control Cable M2X Single Insulated Conductor Cable Application: Used as fixed installation cables in various electromechanical and electronic equipment, including marine switchboards. Usable in all conditions in marine environments, such as dry, wet or oily locations. Specifications: Approved by American Bureau of Shipping, Bureau Veritas Lloyd s Register of Shipping, GL, Class NK, RINA. Construction: Electrolytic stranded annealed copper conductors, IEC Class 5 (Class 2 and/or tinned on request). Low smoke, halogen free. Flame retardant, XLPO insulation (HF90). Color: black. Double insulation available on request. Designation (mm 2 ) O.D. (in.) M2X1X0.50 S20 1X M2X1X0.75 S18 1X M2X1X1.5 S16 1X M2X1X2.5 S14 1X M2X1X4 S12 1X M2X1X6 S10 1X M2X1X10 S16 1X M2X1X16 S26 1X M2X1X25 S41 1X M2X1X35 S66 1X M2X1X50 S106 1X M2X1X70 S133 1X M2X1X95 S212 1X M2X1X120 S250 1X M2X1X150 S300 1X M2X1X185 S400 1X M2X1X240 S500 1X For Low Smoke Zero Halogen Selection Guide, see pages For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60. M2XH Low Smoke Zero Halogen Power and Control Cable Application: Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environments such as dry, wet or oily locations. Rated at 600/1000 volts. Specifications: Approved by American Bureau of Shipping, Lloyd s Register of Shipping, Bureau Veritas, GL, Class NK, RINA. Construction: Electrolytic stranded annealed copper conductor. IEC Class 5 (Class 2 and/or tinned on request). Low smoke, halogen free. XLP insulation. Separating foil or halogen free bedding compound available on request. Flame retardant, thermoplastic, polyolefin-based compound jacket (HM4 / SHF1) HD 604. Color: gray. Designation (mm 2 ) O.D. (in.) M2XH2x1.5 D3 2X M2XH2x2.5 D4 2X M2XH2x4 D6 2X M2XH2x6 D10 2X M2XH3x1.5 T3 3X M2XH3x2.5 T4 3X M2XH3x4 T6 3X M2XH3x6 T10 3X M2XH3x10 T16 3X M2XH3x16 T26 3X M2XH3x25 T41 3X M2XH3x35 T66 3X M2XH3x50 T106 3X M2XH3x70 T133 3X M2XH3x95 T212 3X M2XH3x120 T250 3X For Low Smoke Zero Halogen Selection Guide, see pages For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60. Continued on page 4 3

6 Low Smoke Zero Halogen Power and Control Cable, Single Insulated Conductor M2XH Low Smoke Zero Halogen Power and Control Cable Continued from page 3 Designation (mm 2 ) O.D. (in.) M2XH3x150 T300 3X M2XH3x185 T400 3X M2XH4x1.5 F3 4X M2XH4x2.5 F4 4X M2XH4x4 F6 4X M2XH4x6 F10 4X M2XH4x10 F16 4X M2XH4x16 F26 4X M2XH4x25 F41 4X M2XH4x35 F66 4X M2XH4x50 F106 4X M2XH4x70 F133 4X M2XH4x95 F212 4X M2XH4x120 F250 4X M2XH4x150 F300 4X M2XH4x185 F400 4X M2XH7x1.5 M73 7X M2XH7x2.5 M74 7X M2XH10x1.5 M103 10X M2XH10x2.5 M104 10X M2XH14x1.5 M143 14X M2XH14x2.5 M144 14X M2XH20x1.5 M203 20X M2XH20x2.5 M204 20X M2XH30x1.5 M303 30X M2XH30x2.5 M304 30X For Low Smoke Zero Halogen Selection Guide, see pages For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60. M2XCH Low Smoke Zero Halogen Power and Control Cable, Shielded Application: Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environments such as dry, wet or oily locations, and inside engine rooms. Rated at 60 VDC/250 VAC. Specifications: Approved by American Bureau of Shipping, Bureau Veritas Lloyd s Register of Shipping, GL, Class NK, RINA. Construction: Electrolytic stranded annealed copper conductors, IEC Class 5, (Class 2 and/or tinned on request). Low smoke, halogen free. XLP insulation. Electrolytic, copper-braided shield (90% coverage). M2XCH (EMC) type is wrapped by a copper tape in addition to this shield (100% coverage). Flame retardant, thermoplastic, polyolefin-based compound jacket (HM4/SHF1) HD 604. Color: gray. Designation (mm 2 ) O.D. (in.) M2XCH7X1.5 MS-7-3 7X M2XCH7X2.5 MS-7-4 7X M2XCH10X1.5 MS X M2XCH10X2.5 MS X M2XCH14X1.5 MS X M2XCH14X2.5 MS X M2XCH20X1.5 MS X M2XCH20X2.5 MS X M2XCH30X1.5 MS X M2XCH30X2.5 MS X For a Low Smoke Zero Halogen Selection Guide, see pages For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60. 4

7 Low Smoke Zero Halogen Instrumentation FM2XAH Overall Shielded Instrumentation Cable Application: Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environments such as dry, wet or oily locations, and inside engine rooms. Rated at 60 VDC/250 VAC. Specifications: Approved by American Bureau of Shipping, Lloyd s Register of Shipping, Bureau Veritas, GL, Class NK, RINA. Construction: Electrolytic stranded annealed copper conductors, IEC Class 5 (Class 2 and/or tinned on request). Low smoke, halogen free. XLP insulation. Separating foil below shield. Electrolytic tinned stranded copper drain wire below shield. Aluminum tape shield (100% coverage). Flame retardant, thermoplastic, polyolefin-based compound jacket (HM4/SHF1) HD 604. Color: gray. Designation (mm 2 ) Nominal O.D. (in.) FM2XAH1x2x1.5 TPS161P 1X2X FM2XAH1x2x0.75 TPS181P 1X2X FM2XAH1x2x0.5 TPS201P 1X2X FM2XAH1x3x1.5 TTS161 1X3X For a Low Smoke Zero Halogen Selection Guide, see pages For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60. FM2XAAH, Individual and Overall Shielded Instrumentation Cable Application: Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environments such as dry, wet or oily locations, and inside engine rooms. Rated at 60 VDC/250 VAC. Specifications: Approved by American Bureau of Shipping, Bureau Veritas, Lloyd s Register of Shipping, GL, Class NK, RINA. Construction: Electrolytic stranded annealed copper conductors, IEC Class 5, (Class 2 and/or tinned on request). Low smoke, halogen free. XLP insulation. Separating foil over pairs/triads. Drain wire is electrolytic, tinned, stranded copper drain wire along each pair/triad. Aluminum tape shield over each pair/triad and drain wire bunch, 1 coverage. Flame retardant, thermoplastic, polyolefin-based compound jacket (HM4/SHF1) HD 604. Color: gray. Designation (mm 2 ) Nominal O.D. (in.) FM2XAAH2x2x1.5 TPS162P 2X2X FM2XAAH2x2x0.75 TPS182P 2X2X FM2XAAH2x2x0.5 TPS202P 2X2X FM2XAAH4x2x1.5 TPS164P 4X2X FM2XAAH4x2x0.75 TPS184P 4X2X FM2XAAH4x2x0.5 TPS204P 4X2X FM2XAAH6x2x1.5 TSP166P 6X2X FM2XAAH6x2x0.75 TPS186P 6X2X FM2XAAH6x2x0.5 TPS206P 6X2X FM2XAAH10x2x1.5 TPS1610P 10X2X FM2XAAH10x2x0.75 TPS1810P 10X2X FM2XAAH10x2x0.5 TPS2010P 10X2X FM2XAAH12x2x1.5 TPS1612P 12X2X FM2XAAH14x2x1.5 TPS1614P 14X2X Put Up: Stock items, order to length. Nonstock items, minimum order lengths apply. For a Low Smoke Zero Halogen Selection Guide, see pages For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60. 5

8 Type T/N Power/Distribution Cable Marine Power/Distribution Cable, Type T/N, Unarmored, 600/1000 Volts Application: For use in marine vessels and on fixed and floating offshore facilities. Used for power distribution in circuits or in lighting, communication and control in circuits. Maximum conductor operating temperature: 90 C. Rated at 600 volts. Specifications: IEEE and IEEE (E217848) Certificate , Master Contract UL-309 (E217848) Certificate and Master Contract (LR 84983) per CSA C22.2 No Accepted per US Regulations 46 CFR and U.S. Coast Guard notification letter. Approved by UL and CSA as Type T/N (IEEE), American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Uncoated, soft annealed stranded copper conductors. Insulation dual listed for THHN/THWN (sizes 1/0AWG and larger rated for CT use). Flame retardant and abrasion, chemical, sunlight resistant PVC jacket and sheath. (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) Single Conductor SNIU SNIU SNIU SNIU SNIU SNIU SNIU SNIU SNIU106 1/ SNIU133 2/ SNIU168 3/ SNIU212 4/ SNIU SNIU SNIU SNIU SNIU SNIU SNIU SNIU Conductor DNIU DNIU DNIU DNIU DNIU DNIU DNIU DNIU DNIU106 1/ DNIU133 2/ DNIU168 3/ DNIU212 4/ DNIU DNIU DNIU DNIU DNIU DNIU DNIU Conductor TNIU TNIU TNIU TNIU TNIU TNIU Continued on page 8 6

9 Specialists in Shipboard Cable Armoring Everything You Need for Smooth Sailing from One Convenient Supplier Low Smoke Zero Halogen Cable Marine Cable Industrial Lighting Intercom and Communication Systems Transits and Glands Choose from our broad selection of marine products that meet most national and international certifications, including American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, Underwriters Laboratories and U.S. Coast Guard standards. Lighting products also meet UL standards. Electric Supply s Marine Division offers products and services for the construction, maintenance and repair of offshore vessels and drilling rigs, as well as for inland vessels. In-house cable braiding, custom-length shipboard or rig cables With in-house cable braiding capability and our large shipboard and rig cable inventory, our skilled technicians can armor your custom cable order within a week. Full line of marine electrical products from names you trust is an authorized distributor of 200+ leading manufacturers, including 70 of the biggest names in marine electrical products. Local service with a global reach We send products across the U.S. and over 50 countries worldwide. Marine Division Toll-Free: marine@summit.com

10 Type T/N Power/Distribution Cable Marine Power/Distribution Cable, Type T/N, Unarmored, 600/1000 Volts Continued from page 6 (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) TNIU TNIU TNIU106 1/ TNIU133 2/ TNIU168 3/ TNIU212 4/ TNIU TNIU TNIU TNIU TNIU TNIU TNIU Conductor FNIU FNIU FNIU FNIU FNIU FNIU FNIU FNIU FNIU106 1/ FNIU133 2/ FNIU168 3/ FNIU212 4/ FNIU FNIU FNIU FNIU FNIU FNIU FNIU Marine Power/Distribution Cable, Type T/N, Aluminum Armored, 600/1000 Volts Application: For use in marine vessels and on fixed and floating offshore facilities. Used for power distribution in circuits or in lighting, communication and control in circuits. Maximum conductor operating temperature: 90 C. Rated at 600 volts. Specifications: IEEE and IEEE (E217848) Certificate , Master Contract UL-309 (E217848) Certificate and Master Contract (LR 84983) per CSA C22.2 No Accepted per US Regulations 46 CFR and U.S. Coast Guard notification letter. Approved by UL and CSA as Type T/N (IEEE), American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Uncoated, soft annealed stranded copper conductors. Insulation dual listed for THHN/THWN (sizes 1/0AWG and larger rated for CT use). Flame retardant and abrasion, chemical, sunlight resistant PVC jacket and sheath. (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) 2 Conductor DNIA DNIA DNIA DNIA DNIA DNIA Continued on page 9 8

11 Type T/N Power/Distribution Cable Marine Power/Distribution Cable, Type T/N, Aluminum Armored, 600/1000 Volts Continued from page 8 (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) DNIA DNIA DNIA106 1/ DNIA133 2/ DNIA168 3/ DNIA212 4/ DNIA DNIA DNIA DNIA DNIA DNIA DNIA Conductor TNIA TNIA TNIA TNIA TNIA TNIA TNIA TNIA TNIA106 1/ TNIA133 2/ TNIA168 3/ TNIA212 4/ TNIA TNIA TNIA TNIA TNIA TNIA TNIA Conductor FNIA FNIA FNIA FNIA FNIA FNIA FNIA FNIA FNIA106 1/ FNIA133 2/ FNIA168 3/ FNIA212 4/ FNIA FNIA FNIA FNIA FNIA FNIA FNIA

12 Type T/N Power/Distribution Cable Marine Power/Distribution Cable, Type T/N, Bronze Armored, 600/1000 Volts Application: For use in marine vessels and on fixed and floating offshore facilities. Used for power distribution in circuits or in lighting, communication and control in circuits. Maximum conductor operating temperature: 90 C. Rated at 600 volts. Specifications: IEEE and IEEE (E217848) Certificate , Master Contract UL-309 (E217848) Certificate and Master Contract (LR 84983) per CSA C22.2 No Accepted per US Regulations 46 CFR and U.S. Coast Guard notification letter. Approved by UL and CSA as Type T/N (IEEE), American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Uncoated, soft annealed stranded copper conductors. Insulation dual listed for THHN/THWN (sizes 1/0AWG and larger rated for CT use). Flame retardant and abrasion, chemical, sunlight resistant PVC jacket and sheath. (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) 2 Conductor DNIB DNIB DNIB DNIB DNIB DNIB DNIB DNIB DNIB106 1/ DNIB133 2/ DNIB168 3/ DNIB212 4/ DNIB DNIB DNIB DNIB DNIB DNIB DNIB Conductor TNIB TNIB TNIB TNIB TNIB TNIB TNIB TNIB TNIB106 1/ TNIB133 2/ TNIB168 3/ TNIB212 4/ TNIB TNIB TNIB TNIB TNIB TNIB TNIB Conductor FNIB FNIB FNIB FNIB FNIB FNIB Continued on page 11 10

13 Type T/N Power/Distribution Cable, Control Cable Marine Power/Distribution Cable, Type T/N, Bronze Armored, 600/1000 Volts Continued from page 10 (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) FNIB FNIB FNIB106 1/ FNIB133 2/ FNIB168 3/ FNIB212 4/ FNIB FNIB FNIB FNIB FNIB FNIB FNIB Marine Control Cable, Type T/N, Unarmored, Multi-Conductor 600/1000 Volts Application: Used for marine environments, aboard marine vessels and on fixed and floating offshore facilities. For control, indicating, communication, electronic and similar circuits where multiple conductors are needed. Rated for 600/1000 volts. Specifications: IEEE , IEEE UL , CSA C22.2 No Approved by UL and CSA as Type T/N (AWG) Conductors (IEEE), American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Uncoated soft annealed copper conductors. Flame retardant PVC insulation. Color coded per IEEE, UL, CSA. Cabled round with moisture and flame retardant fillers. Flame retardant, sunlight resistant PVC jacket. Outside Diameter Continued on page (in.) (mm) (lbs./1000 ft.) (kg/km) MNIU2(3) MNIU3(3) MNIU4(3) MNIU7(3) MNIU10(3) MNIU14(3) MNIU16(3) MNIU19(3) MNIU24(3) MNIU30(3) MNIU37(3) MNIU40(3) MNIU61(3) MNIU2(4) MNIU3(4) MNIU4(4) MNIU7(4) MNIU10(4) MNIU14(4) MNIU16(4) MNIU19(4) MNIU24(4) MNIU30(4) MNIU37(4) MNIU40(4) MNIU61(4)

14 Type T/N Control Cable Marine Control Cable, Type T/N, Unarmored, Multi-Conductor 600/1000 Volts Continued from page 11 (AWG) Conductors Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) MNIU2(6) MNIU3(6) MNIU4(6) MNIU7(6) MNIU10(6) MNIU14(6) MNIU16(6) MNIU19(6) MNIU24(6) MNIU30(6) MNIU37(6) MNIU40(6) MNIU61(6) Marine Control Cable, Type T/N, Aluminum Armored, Multi-Conductor 600/1000 Volts Application: Used for marine environments, aboard marine vessels and on fixed and floating offshore facilities. For control, indicating, communication, electronic and similar circuits where multiple conductors are needed. Rated for 600/1000 volts. Specifications: IEEE , IEEE UL , CSA C22.2 No Approved by UL and CSA as Type T/N (AWG) Conductors (IEEE), American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Uncoated soft annealed copper conductors. Flame retardant PVC insulation. Color coded per IEEE, UL, CSA. Cabled round with moisture and flame retardant fillers. Flame retardant, sunlight resistant PVC jacket. Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) MNIA2(3) MNIA3(3) MNIA4(3) MNIA7(3) MNIA10(3) MNIA14(3) MNIA16(3) MNIA19(3) MNIA24(3) MNIA30(3) MNIA37(3) MNIA40(3) MNIA61(3) MNIA2(4) MNIA3(4) MNIA4(4) MNIA7(4) MNIA10(4) MNIA14(4) MNIA16(4) MNIA19(4) MNIA24(4) MNIA30(4) MNIA37(4) MNIA40(4) MNIA61(4) Continued on page 13 12

15 Type T/N Control Cable Marine Control Cable, Type T/N, Aluminum Armored, Multi-Conductor 600/1000 Volts Continued from page 12 (AWG) Conductors Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) MNIA2(6) MNIA3(6) MNIA4(6) MNIA7(6) MNIA10(6) MNIA14(6) MNIA16(6) MNIA19(6) MNIA24(6) MNIA30(6) MNIA37(6) MNIA40(6) MNIA61(6) Marine Control Cable, Type T/N, Bronze Armored, Multi-Conductor 600/1000 Volts Application: Used for marine environments, aboard marine vessels and on fixed and floating offshore facilities. For control, indicating, communication, electronic and similar circuits where multiple conductors are needed. Rated for 600/1000 volts. Specifications: IEEE , IEEE UL , CSA C22.2 No Approved by UL and CSA as Type T/N (AWG) Conductors (IEEE), American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Uncoated soft annealed copper conductors. Flame retardant PVC insulation. Color coded per IEEE, UL, CSA. Cabled round with moisture and flame retardant fillers. Flame retardant, sunlight resistant PVC jacket. Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) MNIB2(3) MNIB3(3) MNIB4(3) MNIB7(3) MNIB10(3) MNIB14(3) MNIB16(3) MNIB19(3) MNIB24(3) MNIB30(3) MNIB37(3) MNIB40(3) MNIB61(3) MNIB2(4) MNIB3(4) MNIB4(4) MNIB7(4) MNIB10(4) MNIB14(4) MNIB16(4) MNIB19(4) MNIB24(4) MNIB30(4) MNIB37(4) MNIB40(4) MNIB61(4) Continued on page 14 13

16 Type T/N Control Cable Marine Control Cable, Type T/N, Bronze Armored, Multi-Conductor 600/1000 Volts Continued from page 13 (AWG) Conductors Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) MNIB2(6) MNIB3(6) MNIB4(6) MNIB7(6) MNIB10(6) MNIB14(6) MNIB16(6) MNIB19(6) MNIB24(6) MNIB30(6) MNIB37(6) MNIB40(6) MNIB61(6) The Roxtec Sealing System Roxtec sealing solutions for cables and pipes ensure safety, efficiency and long-term operational reliability in many different industries. Multidiameter by Roxtec Our invention for adaptability, Multidiameter, is a solution based on rubber modules with removable layers. It allows for a perfect sealing, regardless of the outside dimension of the cable or pipe. This simplifies design, speeds up installation and reduces the need for stock, material and logistics. It also provides built-in spare capacity for future upgrades. Certified safety seals Our seals protect people and investments against risks caused by, for example, fire, gas, water, dust, pests, blast load, and electromagnetic interference. The system is tested and approved by all major classification societies and used in a wide range of applications. Two main product groups There are two main groups of Roxtec products to choose from. The type of application and requirements of protection determine which product to choose. Both groups, RM and CM, are available also in the EMC application area, as well as in the EX application area. Learn more at summit.com/marine 14

17 Type T/N Signal & Instrumentation Marine Signal & Instrumentation, Type T/N, Pairs, IS/OS Shielded Cable, Unarmored, Multi-Conductor 600/1000 Volts Application: For use in marine environments, aboard marine vessels and on fixed and floating offshore facilities. Twisted pairs used for signal transmission. Individual or overall group shielding is to prevent electrostatic and electromagnetic interference. For use in circuits rated for 300 volts. Maximum operating temperature: 90 C. Specifications: IEEE , IEEE UL , CSA C22.2 No IEC Approved by UL, CSA, American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Bare soft annealed stranded copper conductors in twisted, black and white pairs. Color coded with sequential printed numbers. Flame and moisture resistant fillers and binder tape. Abrasion, chemical and sunlight resistant PVC overall jacket. Flame retardant PVC insulation. (AWG) Conductors Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS20TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS18TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU TPS16TIU

18 Type T/N Signal & Instrumentation Marine Signal & Instrumentation, Type T/N, Pairs, IS/OS Shielded Cable, Aluminum Armored, Multi-Conductor 600/1000 Volts Application: For use in marine environments, aboard marine vessels and on fixed and floating offshore facilities. Twisted pairs used for signal transmission. Individual or overall group shielding is to prevent electrostatic and electromagnetic interference. For use in circuits rated for 300 volts. Maximum operating temperature: 90 C. Specifications: IEEE , IEEE UL , CSA C22.2 No IEC Approved by UL, CSA, American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Bare soft annealed stranded copper conductors in twisted, black and white pairs. Color coded with sequential printed numbers. Flame and moisture resistant fillers and binder tape. Standard aluminum armor. Abrasion, chemical and sunlight resistant PVC overall jacket. Flame retardant PVC insulation. (AWG) Conductors Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS20TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS18TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA TPS16TIA

19 Type T/N Signal & Instrumentation Marine Signal & Instrumentation, Type T/N, Pairs, IS/OS Shielded Cable, Bronze Armored, Multi-Conductor 600/1000 Volts Application: For use in marine environments, aboard marine vessels and on fixed and floating offshore facilities. Twisted pairs used for signal transmission. Individual or overall group shielding is to prevent electrostatic and electromagnetic interference. For use in circuits rated for 300 volts. Maximum operating temperature: 90 C. Specifications: IEEE , IEEE UL , CSA C22.2 No IEC Approved by UL, CSA, American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Bare soft annealed stranded copper conductors in twisted, black and white pairs. Color coded with sequential printed numbers. Flame and moisture resistant fillers and binder tape. Standard bronze armor. Abrasion, chemical and sunlight resistant PVC overall jacket. Flame retardant PVC insulation. (AWG) Conductors Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS20TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS18TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB TPS16TIB

20 Type P Power/Distribution Cable Marine Power/Distribution Cable, Type P, 2kV Application: For marine environments, offshore drilling rigs, aboard marine vessels and on fixed and floating offshore facilities. For power distribution in circuits rated for 2,000 volts. Some common applications are DC motor cables, generators, transformers and top drives. Standards: IEEE and IEEE UL CSA C22.2 No Approved by UL and CSA as Type P, American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Tin-coated, soft annealed copper conductors. Flame retardant, sunlight resistant XLPO insulation. Flame retardant, sunlight resistant CP overall jacket. (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) Unarmored DSHP211 4/ DSHP DSHP DSHP DSHP DSHP DSHP DSHP DSHP Bronze Armored and Sheathed DSHPBS211 4/ DSHPBS DSHPBS DSHPBS DSHPBS DSHPBS DSHPBS DSHPBS DSHPBS A2F Cable Glands The CMP A2F Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection, installation and maintenance is observed, e.g. IEC Suitable for hazardous areas with unarmored and braided cable providing a combined flameproof seal and environmental seal on the cable outer sheath. This product provides full compatibility with restricted breathing equipment. Triton CDS Cable Connector (T3CDS) The T3CDS cable connector is available in NPT (standard) or Metric thread forms and the standard material is Brass grade CuZn39Pb3 (CW614N) to EN12168 with Electroless Nickel Plated Brass entry component. This product provides Nema 4X and IP68 ingress protection and is UL listed for use in Class I Zone 1 AEx e II applications and can be used in Class I Division 2 areas when installed in compliance with the NEC requirements. PX2KX Cable Connector The CMP PX2KX cable connector offers Nema 4X and IP68 ingress protection and is supplied in Brass grade CuZn39Pb3 (CW614N) to EN12168 with Electroless Nickel Plated Brass entry component as standard. The PX2KX is also IEC Ex Triple Certified Ex d, Ex e & Ex nr, offering a single solution that can be employed in accordance with both NEC and IEC codes of installation. CABLE GLAND AND CABLE CONNECTION SPECIALISTS 18

21 Type P Power/Distribution Cable Marine Power/Distribution Cable, Type P, Single Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include driller s console, fire and gas detection systems, video camera systems, bilge and ballast controls and general alarm systems. Temperature rating: 110 C. Specifications: IEEE , IEEE UL CSA C22.2 No Approved by UL, CSA, TCMS, American Bureau of (AWG/kcmil) Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Flexible tin-coated, soft annealed copper conductors with polyester separator tape, color coded. Flame retardant, sunlight resistant XLPO insulation. Conductors cabled round with moisture and flame retardant fillers. Flame retardant, sunlight resistant CP jacket. Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) Unarmored DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP105 1/ DSSPCP133 2/ DSSPCP167 3/ DSSPCP211 4/ DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP DSSPCP Bronze Armored and Sheathed DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS105 1/ DSSPBS133 2/ DSSPBS167 3/ DSSPBS211 4/ DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS DSSPBS

22 Type P Power/Distribution Cable Marine Power/Distribution Cable, Type P, 2 Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Common applications are AC motor power, distribution panel feeder, transformer feeder, lighting panels, light fixtures, plugs, receptacles and remote motor controls. Temperature rating: 110 C. Specifications: IEEE , IEEE , UL , CSA C22.2 No Approved by UL, CSA, TCMS, American (AWG/kcmil) Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Flexible tin-coated, soft annealed copper conductors with polyester separator tape, color coded. Flame retardant, sunlight resistant XLPO insulation. Cabled round with moisture and flame retardant fillers. Flame retardant, sunlight resistant CP jacket. Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) 2 Conductor - Unarmored DDPCP DDPCP DDPCP DDPCP DDPCP DDPCP105 1/ DDPCP133 2/ DDPCP167 3/ DDPCP211 4/ DDPCP DDPCP DDPCP DDPCP DDPCP DDPCP Conductor - Bronze Armored and Sheathed DDPCPBS DDPCPBS DDPCPBS DDPCPBS DDPCPBS DDPCPBS105 1/ DDPCPBS133 2/ DDPCPBS167 3/ DDPCPBS211 4/ DDPCPBS DDPCPBS DDPCPBS DDPCPBS DDPCPBS DDPCPBS

23 Type P Power/Distribution Cable Marine Power/Distribution Cable, Type P, 3 Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Common applications are AC motor power, distribution panel feeder, transformer feeder, lighting panels, light fixtures, plugs, receptacles and remote motor controls. Temperature rating: 110 C. Specifications: IEEE , IEEE , UL , CSA C22.2 No Approved by UL, CSA, TCMS, American (AWG/kcmil) Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Flexible tin-coated, soft annealed copper conductors with polyester separator tape, color coded. Flame retardant, sunlight resistant XLPO insulation. Cabled round with moisture and flame retardant fillers. Flame retardant, sunlight resistant CP jacket. Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) 3 Conductor - Unarmored DTPCP DTPCP DTPCP DTPCP DTPCP DTPCP105 1/ DTPCP133 2/ DTPCP167 3/ DTPCP211 4/ DTPCP DTPCP DTPCP DTPCP DTPCP DTPCP Conductor - Bronze Armored and Sheathed DTPCPBS DTPCPBS DTPCPBS DTPCPBS DTPCPBS DTPCPBS105 1/ DTPCPBS133 2/ DTPCPBS167 3/ DTPCPBS211 4/ DTPCPBS DTPCPBS DTPCPBS DTPCPBS DTPCPBS

24 Type P Power/Distribution Cable Marine Power/Distribution Cable, Type P, 4 Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Common applications are AC motor power, distribution panel feeder, transformer feeder, lighting panels, light fixtures, plugs, receptacles and remote motor controls. Temperature rating: 110 C. Specifications: IEEE , IEEE , UL , CSA C22.2 No Approved by UL, CSA, TCMS, American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Flexible tin-coated, soft annealed copper conductors with polyester separator tape, color coded. Flame retardant, sunlight resistant XLPO insulation. Cabled round with moisture and flame retardant fillers. Flame retardant, sunlight resistant CP jacket. (AWG/kcmil) Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) 4 Conductor - Unarmored DFPCP DFPCP DFPCP DFPCP DFPCP DFPCP105 1/ DFPCP133 2/ DFPCP167 3/ DFPCP211 4/ DFPCP DFPCP DFPCP DFPCP DFPCP DFPCP Conductor - Bronze Armored and Sheathed DFPCPBS DFPCPBS DFPCPBS DFPCPBS DFPCPBS DFPCPBS105 1/ DFPCPBS133 2/ DFPCPBS167 3/ DFPCPBS211 4/ DFPCPBS DFPCPBS DFPCPBS DFPCPBS

25 Type P Control Cable Marine Control Cable, Type P, 600 Volts Application: For use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic and similar circuits where multiple conductor cables are required. Used for driller s console, fire and gas detection systems, video camera systems, bilge and ballast controls and general alarm systems. Temperature rating: 110 C. Specifications: IEEE , IEEE , UL , CSA C22.2 No Approved by UL, CSA, TCMS, American Bureau of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, United States Coast Guard. Construction: Flexible tin-coated, soft annealed copper conductors with polyester separator tape, color coded. Flame retardant, sunlight resistant XLPO insulation. Cabled round with moisture and flame retardant fillers. Flame retardant, abrasion and sunlight resistant CP jacket. Conductors Jacket Thickness Outside Diameter (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) 16 AWG, 26 - Unarmored DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP DC16PCP AWG, 26 - Bronze Armored and Sheathed DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS DC16PCPBS Continued on page 24 23

26 Type P Control Cable Marine Control Cable, Type P, 600 Volts Continued from page 23 Conductors Jacket Thickness Outside Diameter (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) 14 AWG, 41 - Unarmored DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP DC14PCP AWG, 41 - Bronze Armored and Sheathed DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS DC14PCPBS AWG, 65 - Unarmored DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP Continued on page 25 24

27 Type P Control Cable Marine Control Cable, Type P, 600 Volts Continued from page 24 Conductors Jacket Thickness Outside Diameter (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP DC12PCP AWG, 65 - Bronze Armored and Sheathed DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS DC12PCPBS AWG, Unarmored DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP Continued on page 26 25

28 Type P Control Cable Marine Control Cable, Type P, 600 Volts Continued from page 25 Conductors Jacket Thickness Outside Diameter (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP DC10PCP AWG, Bronze Armored and Sheathed DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS DC10PCPBS

29 Type P Signal & Instrumentation Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, /1000 Volts Application: For use in signal transmission applications where of Shipping, Det Norske Veritas, Lloyd s Register of Shipping, maximum protection from electromagnetic interference is United States Coast Guard. needed. For use in marine environments on offshore drilling rigs, aboard marine vessels, or on fixed and floating offshore facilities. Used in tank level indicators, fire and gas protection systems, communication systems, CO2 systems, and smoke detectors. Temperature rating: 110 C. Specifications: IEEE , IEEE UL-1685, UL CSA C22.2 No IEEE 383 and 1202 Flame Tests. ICEA T IEC 332 Category A 210,000 BTU/hr Flame Test. ICEA T Approved by UL, CSA, TCMS, American Bureau Construction: Flexible tin-coated, soft annealed copper conductors, twisted pairs or triads color coded with sequential printed numbers. Pairs use black and white; triads use black, white, red. Flame retardant, sunlight resistant XLPO insulation. Cabled round with moisture and flame resistant fillers and binder tape. Individual and overall shielding with aluminum/ polyester tape, 100% coverage, and drain wire. Flame retardant, sunlight resistant CP jacket. Standard bronze armor. Oil, chemical, sunlight and abrasion resistant CP sheathing. Pairs Outside Diameter 27 (in.) (mm) (lbs./1000 ft.) (kg/km) Pairs - 20 AWG, 10 - Unarmored DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP DTPS20PCP Pairs - 20 AWG, 10 - Bronze Armored and Sheathed DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS DTPS20PCPBS Pairs - 18 AWG, 16 - Unarmored DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP Continued on page 28

30 Type P Signal & Instrumentation Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, /1000 Volts Continued from page 27 Pairs Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP DTPS18PCP Pairs - 18 AWG, 16 - Bronze Armored and Sheathed DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS DTPS18PCPBS Pairs - 16 AWG, 26 - Unarmored DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP DTPS16PCP Pairs - 16 AWG, 26 - Bronze Armored and Sheathed DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS DTPS16PCPBS Continued on page 29 28

31 Type P Signal & Instrumentation Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, /1000 Volts Continued from page 28 Pairs Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) DTPS16PCPBS DTPS16PCPBS Pairs - 14 AWG, 41 - Unarmored DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP DTPS14PCP Pairs - 14 AWG, 41 - Bronze Armored and Sheathed DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS DTPS14PCPBS Triads - 18 AWG, 16 - Unarmored DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP DTTS18PCP Continued on page 30 29

32 Type P Signal & Instrumentation Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, /1000 Volts Continued from page 29 Pairs Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) Triads - 18 AWG, 16 - Bronze Armored and Sheathed DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS DTTS18PCPBS Triads - 16 AWG, 26 - Unarmored DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP DTTS16PCP Triads - 16 AWG, 26 - Bronze Armored and Sheathed DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS DTTS16PCPBS Triads - 14 AWG, 41 - Unarmored DTTS14PCP DTTS14PCP DTTS14PCP Continued on page 31 30

33 Type P Signal & Instrumentation Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, /1000 Volts Continued from page 30 Pairs Outside Diameter (in.) (mm) (lbs./1000 ft.) (kg/km) DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP DTTS14PCP Triads - 14 AWG, 41 - Bronze Armored and Sheathed DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS DTTS14PCPBS We Stock a Wide Variety of Cable Glands ATEX glands EX d,e both potted and unpotted. We also stock North American NEC glands potted and unpotted for hazardous and non-hazardous applications. Learn more at summit.com/marine Marine Division Toll-Free: marine@summit.com 31

34 Banding Tools and Supplies Manual Cable Tools Hayata CT3 manual tool tensions and cuts steel ties. Offers close cut to the head when removing tail of stainless steel tie. Hayata CT5 Manual Cable Tool Manual tool with preset tension adjustment control, which allows for uniform tension setting and automatic cutting on each bundle. Lightweight, one-hand operation. Hayata Tough Tool This tensioning tool with built-in cutter provides up to 2400 lbs of tension and can be used on band, free-end clamps, fix band and coated band. Powder coat finish helps protect the tool from corrosion. Hayata Gorilla Tool Designed to be used with heavy duty band or applications where 6000 lbs of torque may be required. 32 HYCT5 HYTT2400 HYGT6000 HYCT3 Hayata BT12000 QuikTie Battery Powered Cable Tool Hayata s most advanced battery operated cable tie installation tool. Built for speed and productivity, the Hayata BT12000 QuikTie delivers longer-lasting power in a more compact tool that s 50 percent lighter than the previous model. The BT12000 is ideal for continuous overhead work as well as tight, hard-to-reach corners. 4:1 productivity ratio advantage over standard tools 12 volt tool 20 clutch setting Produces 220 pounds of torque, variable torque adjustment Easy manual cut-off lever; no jagged edges because the tool cuts smoothly and close to the head every time 30-minute rechargeable Lithium Ion battery Delivers uniform tension for each installation, which means consistent tensioning for the entire job Offers more control over tension vs. manual tools, lowering risk of damage to the cable jacket Hayata BTX 6000 Battery Powered Banding Tool The first battery powered banding tool on the market, the Hayata BTX6000 is ideal for installing both coated and uncoated banding ranging in widths from 1/4" to 3/4". 4:1 productivity ratio advantage over standard tools 18 volt tool Variable torque adjustment Easy manual cut-off lever 30-minute rechargeable battery (2 included) Delivers uniform tension for each installation, which means consistant tensioning for the entire job Offers more control over tension vs. manual tools, lowering risk of damage to the cable jacket Hayata Tough Band HYBTX6000 Hayata Stainless Steel Coated Bands Hayata Super Coated Banding provides the ultimate protection for any bundling application where extreme weather, corrosion, salt spray, and chemicals may be present. The coating provides an extra layer of protection for the 316 Stainless Steel as well as a way to insulate the bundle and separate dissimilar metals. Hayata Super Coated Band is a must for offshore and marine applications. Thickness Width Buckle Type in. mm in. mm lbs. kg HYCB / HYCB / HYCB / HYCB / HYCB / Thickness Width Buckle Type in. mm in. mm lbs. kg HYSB / HYSB / HYSB / HYSB / HYSB / HYSB / HYSB / Tiger Teeth 316 SS HYBT12000 Wing Seals 316SS

35 Building Wire Copper THHN/THWN/THWN-2, Copper Conductor, 600 Volts Application: Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. Type THHN or T90 conductor suitable for use in dry locations, temperatures not to exceed 90 C. Type THWN-2 or TWN75 conductor suitable for use in wet or dry locations. Temperatures not to exceed 90 C or 75 C when exposed to oil. Temperatures not to exceed 105 C in dry locations when rated AWM and used as appliance wiring material. Rated at 600 volts. Specifications: Meets ASTM specifications. UL-83, UL-1063, UL C22.2 No Federal Specification A-A National Electrical Code. RoHS/REACH compliant. NEMA/WC 70. Construction: Soft annealed copper conductors, unilay compressed strand. Heat and moisture resistant PVC insulation. Nylon (or UL- recognized equal) jacket. (AWG/kcmil) Insulation Thickness (mils) Jacket Thickness (mils) Nominal O.D. (in.) (lbs./1000 ft.) 14SOL*** 14 Solid SOL*** 12 Solid SOL*** 10 Solid STR*** STR*** STR*** STR*** STR*** STR*** STR*** STR*** STR*** /0CUT 1/ /0CUT 2/ /0CUT 3/ /0CUT 4/ CUT CUT CUT CUT CUT CUT CUT Pre-lubricated product (i.e. Southwire SIMpull, Encore Super Slick, etc.) is available on request. *** Specify color with 3-letter color code. Example: 14SOLRED. Black =BLA Green =GRE Blue =BLU Brown =BRO Purple =PUR Pink =PIN Green w/yellow Stripe =G/Y White =WHI Red =RED Orange =ORA Yellow =YEL Gray =GRA Tan =TAN XHHW/XHHW-2, Copper Conductor, 600 Volts Application: Primarily used in conduit or other recognized raceways for services, feeders,and branch circuit wiring. May be used in wet or dry locations at temperatures not to exceed 90 C. Rated at 600 volts. Construction: Soft annealed copper conductor. Abrasion, moisture, heat resistant XLP insulation. Specifications: UL-44. ASTM B-3, B-8. Federal Specification A-A ICEA S NEMA/WC 70. IEEE 1202 (70,000 BTU/hr) Flame Test. CSA FT-4 Flame Test. (AWG/kcmil) Insulation Thickness (mils) Nominal O.D. (in.) (lbs./1000 ft.) 14XHHW*** XHHW*** XHHW*** XHHW*** XHHW*** XHHW*** Pre-lubricated product (i.e. Southwire SIMpull, Encore Super Slick, etc.) is available on request. Continued on page 34 33

36 Building Wire Copper XHHW Copper Conductor, 600 Volts Continued from page 33 (AWG/kcmil) Insulation Thickness (mils) Nominal O.D. (in.) (lbs./1000 ft.) 2XHHW*** XHHW*** /0XHHW 1/ /0XHHW 2/ /0XHHW 3/ /0XHHW 4/ XHHW XHHW XHHW XHHW XHHW XHHW XHHW XHHW XHHW Pre-lubricated product (i.e. Southwire SIMpull, Encore Super Slick, etc.) is available on request. *** Specify color with 3-letter color code. Example: 14XHHWRED. Black =BLA Green =GRE Blue =BLU Brown =BRO Purple =PUR Pink =PIN White =WHI Red =RED Orange =ORA Yellow =YEL Gray =GRA Tan =TAN RHH/RHW/USE, Copper Conductors, 600 Volts Application: Suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90 C. Type RHH conductor temperatures shall not exceed 90 C in dry locations. When used as RHW-2 or USE-2, temperatures shall not exceed 90 C in wet or dry locations. Rated at 600 volts. Specifications: UL-44 (for RHH or RHW-2), UL-854 (for USE 2). ASTM B-3, B-8, B Federal Specification A-A National Electrical Code. ICEA S NEMA/WC70. Construction: Soft annealed copper conductors. Abrasion, moisture, heat, and sunlight resistant XLP insulation. (AWG/kcmil) Insulation Thickness (mils) Nominal O.D. (in.) (lbs./1000 ft.) 14USE USE USE USE USE USE USE USE /0USE 1/ /0USE 2/ /0USE 3/ /0USE 4/ USE USE USE USE USE USE USE USE USE USE USE

37 Building Wire Copper Underground Feeder Cable, Copper Conductors with Ground, 600 Volts Application: Generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building. May be used underground, including direct burial. May be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors). Rated at 600 volts. Specifications: UL-83, UL-493. Federal Specification A-A National Electrical Code. Construction: Soft annealed copper conductors, solid or compressed stranded. PVC insulation. Nylon jacket. (AWG/kcmil) Insulation Thickness Conductors (mils) Jacket Thickness (mils) Nominal O.D. (in.) (lbs./1000 ft.) 142UFWG Solid.185 x UFWG Solid.195 x UFWG Solid.230 x UFWG x UFWG x UFWG Solid.185 x UFWG Solid.195 x UFWG Solid.230 x UFWG x UFWG x Around the Clock Convenience With s online services, you can: Compare products and see available inventory Get your account-specific pricing Place orders any time, day or night Track shipments and see proof of delivery Access order history, invoices and credit memos Learn more at summit.com/ebusiness 35

38 Cord Flexible Portable Cord SJEOOW, 300 Volts Application: Used as wiring for industrial machinery, heavyduty tools, motors, and temporary electrical power and lighting installations for construction sites. Flexible and durable in harsh environments where oil resistance and extended service life are required. Temperature rating: -50 C to 105 C dry locations. May be used in wet locations (even completely immersed in water) when exposed to oil or coolant at temperatures not greater than 60 C. Rated as hard-usage service cord. Rated at 300 volts. Specifications: UL-62. CSA Standard 22.2 No. 49. CSA FT2. CSA Certified as Type SJTOOW (TPE). MSHA flame resistance for mining applications. Federal Specification J-C-580B. OSHA acceptable. RoHS compliant. National Electrical Code. ASTM B-174. Construction: Bare flexible copper conductors, Class K stranding. Heat, moisture and oil resistant 105 C color-coded TPE insulation. Cabled with non-wicking polypropylene fillers, with tissue-paper separator wrapped around assembly for easier removal of jacket. Heat, moisture and oil resistant, flexible TPE jacket. (AWG/kcmil) Conductors Insulation Thickness (in.) Jacket Thickness (in) O.D. (in.) (lbs./1000 ft.) SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJEOOW SJOOW, 300 Volts Application: Used as wiring for portable tools, portable appliances, equipment, small motors and associated machinery. UL Listed and CSA Certified for indoor/outdoor use. Oil and water resistant. High flexibility. Rated as hard usage service cord. Temperature rating: -40 C to 90 C. Rated at 300 volts. Specifications: UL-62. CSA Standard 22.2 No. 49. MSHA flame resistance for mining applications (P-136-MSHA). Federal Specification J-C-580B. OSHA acceptable. RoHS compliant. National Electrical Code. ASTM B-174. Construction: Bare flexible copper conductors, Class K stranding. Heat, moisture and oil resistant EPDM rubber insulation. Cabled with wax paper fillers, with tissue-paper separator wrapped around assembly for easier removal of jacket. Heat, moisture and oil resistant, flexible CPE jacket. (AWG/kcmil) Conductors Insulation Thickness (in.) Jacket Thickness (in.) O.D. (in.) (lbs./1000 ft.) SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW SJOOW

39 Cord Flexible Portable Cord SOOW, 600 Volts Application: Designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights welding leads, marine dockside power, power extensions and mining applications. Also may be used for special applications outlined in NFPA 70 for Class I Division1 and 2, Class II Division 1 and 2 locations. For indoor/outdoor use, and for continuous submersion in water. Temperature rating: -40 C to 90 C. Rated at 600 volts. Specifications: UL-62. CSA Standard C22.2 No. 49. OSHA acceptable. MSHA Listed. MSHA Flame Test (P-136-MSHA). FT-1 and FT-2 Flame Test. RoHS compliant. National Electrical Code. Construction: Bare flexible copper conductors, Class K stranding. Heat, moisture and oil resistant EPDM rubber insulation. Cabled with wax paper fillers, with tissue-paper separator wrapped around assembly for easier removal of jacket. Heat, moisture and oil resistant, flexible CPE jacket. Also available in yellow. Contact for details. (AWG/kcmil) Conductors Insulation Thickness (in.) Jacket Thickness (in.) O.D. (in.) (lbs./1000 ft.) SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW Continued on page 38 37

40 Cord Flexible Portable Cord SOOW, 600 Volts Continued from page 37 (AWG/kcmil) Conductors Insulation Thickness (in.) Jacket Thickness (in.) O.D. (in.) (lbs./1000 ft.) SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW SOOW

41 Cord Flexible Portable Cord, Portable Power SEOOW, 600 Volts Application: Used as wiring for industrial machinery, heavyduty tools, motors, and temporary electrical power and lighting installations for construction sites. Flexible and durable in harsh environments where oil resistance and extended service life are required. Temperature rating: -50 C to 105 C dry locations. May be used in wet locations (even completely immersed in water) when exposed to oil or coolant at temperatures not greater than 60 C. Rated as hard-usage service cord. Specifications: UL-62 approved. Meets CSA Standard 22.2 No. 49. MSHA Listed. Federal Specification J-C-580B. OSHA acceptable. RoHS compliant. National Electrical Code. ASTM B-174. Construction: Bare flexible copper conductors, Class K stranding. Heat, moisture and oil resistant 105 C color-coded TPE insulation. Cabled with non-wicking polypropylene fillers, with tissue-paper separator wrapped around assembly for easier removal of jacket. Heat, moisture and oil resistant, flexible TPE jacket. (AWG/kcmil) Conductors Insulation Thickness (in.) Jacket Thickness (in.) O.D. (in.) (lbs./1000 ft.) SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW SEOOW Bus Drop Cable, 600 Volts Application: For use in indoor or outdoor applications for connection of stationary or portable equipment to facilitate relocation of equipment.used in wet or dry locations. Resistant to oils, lubricants, acids, alkalies, ozone, water and abrasion. Temperature rating: -20 C to 75 C (14-8 AWG), 60 C (6-2 AWG). Rated at 600 volts. Specifications: UL Listed. OSHA acceptable. RoHS compliant. ASTM B-8, B-174. Construction: Annealed bare copper conductors, stranded. PVC insulation. Conductors and ground wires, along with paper or polypropylene fillers, cabled for flexibility, wrapped with mylar separator to aid strippability. PVC jacket. (AWG/ kcmil) Conductors Ground Wire (AWG) Ground Wires Insulation Thickness (mils) Jacket Nominal O.D. Thickness (in.) (mils) (lbs./1000 ft.) BUSDROP BUSDROP BUSDROP BUSDROP BUSDROP BUSDROP BUSDROP

42 Cord Portable Power Hook-Up Wire, MTW/TEW or AWM, 600 Volts Application: Used for machine tool wiring, and internal wiring of appliances, including wiring for refrigeration equipment, air-conditioning equipment, control wiring of machine tools, automatic washers, etc. Machine tool wire rated at 600 volts. Temperature rating: -40 C to 90 C (ampacity limited to 75 C). Type TEW rating permits use in (i) dry locations not to exceed 105 C; or (ii) wet locations or other applicable locations when exposed to oil or coolant at temperatures not to exceed 60 C. When used as AWM, intended uses limited to dry locations at temperatures not to exceed 105 C (applicable to both UL and CSA ratings). Specifications: ASTM B-174 (sizes AWG), ASTM B-787 (sizes 8-2 AWG). UL-1063, UL-1015 and Subject 758. CSA C22.2 No and No Federal and Military Specification J-C-30B. National Electrical Code NFPA 70 and 79. OSHA acceptable. RoHS compliant. UL VW-1 and CSA FT-1. Construction: Bare flexible copper conductors, Class K stranding (sizes AWG), and combination unilay stranding (sizes 8-2 AWG). Heat and moisture resistant PVC insulation. (AWG/kcmil) Insulation Thickness (mils) O.D. (in.) (lbs./1000 ft.) MTW MTW MTW MTW MTW MTW MTW MTW MTW Welding Cable, Single Copper Conductor, 600 Volts Application: Used in welding applications for connections between electrode holder and clamp, to arc welder, bus, welding box or transformer. For use in industrial applications such as shipyards, mines and construction sites. Flexible and durable in harsh environments. Temperature rating: -40 C to 90 C. Rated at 600 volts. Specifications: ASTM B-3, B-172. Construction: Bare flexible copper conductor, Class K stranding. EPDM rubber insulation. (AWG/kcmil) Nominal O.D. (in.) (lbs./1000 ft.) WELD WELD WELD WELD WELD WELD1/0 1/ WELD2/0 2/ WELD3/0 3/ WELD4/0 4/ WELD WELD WELD Diesel Locomotive, Single Copper Conductor (RHH/RHW), 2kV Application: Used in diesel electric locomotive and car equipment, mining, general construction, temporary power supply motor lead, and cable tray when CT rated. Flexible and durable in harsh environments. Temperature rating: 90 C. Rated at 2,000 volts. Specifications: UL-1658 Vertical Cable Tray Flame Test. IEEE 383 (70,000 BTU/hr) Flame Test. MSHA approved. ICEA S , NEMA WC-70, Association of American Railroads (AAR). ASTM B-33, B-172, B-174. Construction: Tin-coated soft annealed copper conductor. EPR rubber insulation. CPE jacket. (AWG/kcmil) Insulation Thickness (mils) Jacket Thickness (mils) Area (circular mils) O.D. (in.) (lbs./1000 ft.) DLO2KV DLO2KV Continued on page 41 40

43 Cord Portable Power Diesel Locomotive, Single Copper Conductor (RHH/RHW), 2kV Continued from page 40 (AWG/kcmil) Insulation Thickness (mils) Jacket Thickness (mils) Area (circular mils) O.D. (in.) (lbs./1000 ft.) DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV1/0 1/ DLO2KV2/0 2/ DLO2KV3/0 3/ DLO2KV4/0 4/ DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV DLO2KV The Tool Every Electrician Needs. Formulas, tables, charts and diagrams that you can use every day on every job. Now updated for the 2011 NEC. Learn more at summit.com/refbook 41

44 Cord Portable Power Type G & G-GC Round Power Cable with Ground, 2kV Application: Used in industrial and light- to medium-duty mining applications, heavy-duty service as power supply cable, power cable for mobile and portable electrical equipment. Temperature rating: -40 C to 90 C. 90 C dry locations, 75 C wet locations. May be used in marina (wet) locations. Suitable for use on three-phase AC systems where 3 or 4 conductors are needed and grounding is required. Flexible and resistant to oils, solvents, ozone, aging and abrasion. Rated at 2,000 volts. Specifications: UL and c(ul) Listed. UL-1650 and FT-5 Flame Test. MSHA approved. RoHS compliant. Construction: Annealed copper conductors, stranded. EPDM insulation. CPE rubber jacket. (AWG/ kcmil) Conductors* Ground Check (AWG) Ground Conductor Conductors (AWG) Insulation Thickness (in.) O.D. (in.) Ampacity (lbs./ 1000 ft.) G2KV83GGC G2KV63GGC G2KV43GGC G2KV23GGC G2KV13GGC G2KV1/03GGC 1/ G2KV2/03GGC 2/ G2KV3/03GGC 3/ G2KV4/03GGC 4/ G2KV2503GGC G2KV3503GGC / / G2KV5003GGC / / G2KV84GC G2KV64GC G2KV44GC G2KV24GC G2KV14GC G2KV1/04GC 1/ G2KV2/04GC 2/ G2KV3/04GC 3/ G2KV4/04GC 4/ G2KV2504GC G2KV3504GC / G2KV5004GC / *3 Conductor with Ground Check Type W Portable Power Cable, 2kV Application: For use in industrial and light-to-medium mining applications, heavy-duty service, and temporary as power supply cables. Also used for motor, battery and generator leads, mobile and portable electrical equipment. Temperature rating: -40 C to 90 C. Rated at 2,000 volts. Specifications: UL Listed as Type RHH or RHW-2, and UL as Type W. NEMA WC-58. FT-5 Flame Test. ICEA S MSHA accepted, P , LR ASTM B-172. CSA or c(ul) certified as applicable. RoHS Compliant. Construction: Annealed copper conductors, stranded. EP rubber insulation. CPE rubber jacket. Conductors (AWG/kcmil) Nominal Insulation Thickness Nominal Cable O.D. (in.) (mm) (in.) (mm) (lbs./1000ft.) W W W W W W1/0 1 1/ W2/0 1 2/ *UL listed only. Multiconductor cables are UL and C(UL) unless marked. Continued on page 43 42

45 Cord Portable Power Type W Portable Power Cable, 2kV Continued from page 42 Conductors (AWG/kcmil) Nominal Insulation Thickness Nominal Cable O.D. (in.) (mm) (in.) (mm) (lbs./1000ft.) W3/0 1 3/ W4/0 1 4/ W W W W W W W W W1/02 2 1/ W2/02 2 2/ W3/02 2 3/ W4/02 2 4/ W W W W W W1/03 3 1/ W2/03 3 2/ W3/03 3 3/ W4/03 3 4/0* W * W * W * W W W W W W1/04 4 1/ W2/04 4 2/ W3/04 4 3/0* W4/04 4 4/0* W W W W W W1/05 5 1/ W2/05 5 2/0* W3/05 5 3/0* W4/05 5 4/0* *UL listed only. Multiconductor cables are UL and C(UL) unless marked. 43

46 Cord Cord Sets SJEOW Extension Cord, Single Tap Application: General purpose extension cord for indoor use. Rated for hard usage. Temperature rating -50 C to 90 C. Rated at 125 volts. Specifications: UL Listed for outdoor use. NEMA National Electrical Code. RoHS compliant. Construction: Clear PVC plug and connector with neon power indicator lamp in the cord connector. TPE jacket. (AWG/kcmil) Conductors Nominal O.D. (in.) Amps Length (ft.) 163EXT EXT EXT EXT EXT EXT EXT EXT EXT EXT EXT EXT SEOW Extension Cord, Triple Tap Application: Three-receptacle adapter cord set rated for extra hard usage. Temperature rating -55 C to 90 C. Rated at 125 volts. Specifications: UL Listed. NEMA National Electrical Code. Construction: Clear PVC plug and connector with neon power indicator lamp in cord connector. TPE jacket. (AWG/kcmil) Conductors Nominal O.D. (in.) Amps Length (ft.) 123EXTTT EXTTT EXTTT EXTTT SJEOW Extension Cord, Quad Tap Application: General purpose extension cord. Rated for hard usage. Temperature rating -50 C to 90 C. Rated at 125 volts. Specifications: UL Listed. NEMA National Electrical Code. RoHS compliant. Construction: Clear PVC plug and connector with neon power indicator lamp in the cord connector. TPE jacket. (AWG/kcmil) Conductors Nominal O.D. (in.) Amps Length (ft.) 123EXTQT EXTQT EXTQT EXTQT

47 Impervious Continuously Welded Impervious Continuously Welded (ICW) Armored Instrumentation Cable, Individual and Overall Shielded, 600 Volt Applications: For use where 600 volt instrumentation cables with individually shielded pairs or triads and an overall shield are required. Provide liability against physical damage for use in instrumentation and process control applications where shielding against both external EMI and EMI between groups is required. For use in Class1 remote-control and signal circuits in accordance with NEC Article 725. Recognized for use in Class I, II and III, Divisions 1 and 2; or Class I, Zones1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505 Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays,or for direct burial. Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute. Specifications: UL 83 thermoplastic insulated wire and cables. UL 1569 metal clad cables UL 2225 cables and cable fittings for use in hazardous locations. UL 1309/CSA C22.2 No. 245 marine shipboard cable. Flame tests ICEA T (210,000 BTU/hr), IEEE 383 (70,000 BTU/hr), CSA FT4, IEEE 1202 (70,000 BTU/ hr), UL 1581 (70,000 BTU/hr), IEC Cat. A. Complies with UL Type MC-HL, CT USE, SUN RES,DIR BUR, -40 C, UL File # E69797 UL listed marine shipboard, UL File #E85994 American Bureau of Shipping (ABS). Rated for 600 volts, cable tray use and direct burial. Construction: Conductors are bare annealed copper per ASTM B3 Class B stranding per ASTM B8. Flame-retardant polyvinyl chloride(pvc) insulation and nylon covering rated 90 C per UL Standard 83. Color-coded per ICEA Method 1 (pairs black and white; triads black,white and red). Each conductor in each pair or triad is printed alpha numerically for easy identification. Twisted pairs have aluminum/polyester tape shielding which provides 100% coverage. Stranded, tinned copper drain wires are two sizes smaller than insulated conductors. Individually shielded pairs or triads are cabled together with a left-hand lay. Stranded, tinned copper drain wire in the overall shield is the same size as insulated conductors. The inner jacket is flame-retardant PVC per UL Standard 1569, black. Low temperature performance meets ASTM D746 brittleness temperature at or below -40 C. Nylon rip cord to facilitate jacket removal. Conductor (AWG) Pairs/ Triads Insulation Thickness (mils) Inner Jacket Thickness (mils) Nominal Core O.D. (in.) Nominal Armor O.D. (in.) Overall Jacket Thickness (mils) Nominal Overall O.D. (in.) Cross Section Area (sq. in.) (lbs./ 1000ft.) Conductor Pairs ICW182SPOS ICW184SPOS ICW188SPOS ICW1812SPOS ICW1816SPOS ICW1824SPOS ICW162SPOS ICW164SPOS ICW166SPOS ICW168SPOS ICW1610SPOS ICW1612SPOS ICW1616SPOS ICW1620SPOS ICW1624SPOS ICW1636SPOS ICW1650SPOS Conductor Triads ICW164STOS ICW168STOS ICW1612STOS ICW1616STOS ICW1624STOS ICW1636STOS Dimensions and weights are nominal; subject to industry tolerances. Cross-sectional area for cable tray fill is in accordance with NEC Section

48 Impervious Continuously Welded Impervious Continuously Welded (ICW) Armored Power and Control Cable, 600 Volts Application: For use in harsh environments where maximum conductor protection is required. Prevents entrance of water, gas and corrosive elements into electrical core. Used for power, control and lighting circuits in commercial and industrial environments. Approved for wet or dry locations at 90 C. For use indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL approved for use at 90 C for continuous operation, 130 C for emergency overload conditions, and 250 C for short circuit conditions. May be used in Class I Division 2 Hazardous Locations. Specifications: UL listed Type CWCMC. IEEE 45/IEEE 1580 (46 CFR Part ) Marine Shipboard Cable. UL-1581 (70,000 BTU/hr) Flame Test. ICEA 70,000 BTU/hr and 210,000 BTU/hr Flame Tests. IEEE 383 (70,000 BTU/hr) Flame Test. CSA-C22.2 No. 0.3, -40 C Cold Impact Test. ASTM B-3, B-8, B-496. Construction: Soft bare annealed copper conductors, Class B stranding. Aluminum armor. XLP and Type XHHW-2 insulation. Flame retardant and sunlight resistant PVC jacket. (AWG/ kcmil) Conductors Insulation Thickness (mils) Jacket Thickness (mils) Ground Wire Conductors (AWG) Armor Diameter (in.) Nominal O.D. (in.) (lbs./ 1000 ft.) ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW1/03 1/ ICW1/04 1/ ICW2/03 2/ ICW2/04 2/ ICW3/04 3/ ICW3/03 3/ ICW4/03 4/ ICW4/04 4/ ICW ICW ICW ICW ICW ICW ICW

49 Impervious Continuously Welded Impervious Continuously Welded (ICW) Armored Power Cable, Unshielded, 2.4kV Application: For use in primary power and distribution circuits up to 2.4kV when installed in open air, conduit, duct, cable tray when CT rated, or direct buried in earth. For use in wet or dry locations at 105 C. For commercial and industrial applications. Approved for use at 105 C for continuous operation, 140 C for emergency overload conditions, and 250 C for short circuit conditions. (AWG/ kcmil) Conductors Specifications: IEEE 383 (70,000 BTU/hr) Flame Test. ICEA S /NEMA WC71. ASTM B-3, B-8, B-496. Construction: Soft bare annealed copper conductors, Class B stranding. Aluminum armor. EPR insulation, 133% insulation level. Flame retardant and sunlight resistant PVC jacket. Insulation Thickness (mils) Jacket Thickness (mils) Insulation Diameter (in.) Copper Ground Wire (AWG) O.D. (in.) (lbs./ 1000 ft.) ICW632KVEPRPVC ICW432KVEPRPVC ICW232KVEPRPVC ICW132KVEPRPVC ICW1/032KVEPRPVC 1/ ICW2/032KVEPRPVC 2/ ICW3/032KVEPRPVC 3/ ICW4/032KVEPRPVC 4/ ICW25032KVEPRPVC ICW35032KVEPRPVC ICW50032KVEPRPVC ICW75032KVEPRPVC Mobile Apps for the Electrician Useful applications that you can use on the jobsite. Developed by for the busy electrician. New apps are added frequently. Learn more at summit.com/mobile 47

50 Impervious Continuously Welded Impervious Continuously Welded (ICW) Armored Power Cable, Unshielded, 5kV 133% / 8kV 100% Insulation Level, Shielded Applications: Variable frequency drives or for use as feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330. For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505. May be installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart. Specifications: Design adherence: ICEA S /WC-74, 5-46 kv shielded power cable. AEIC CS8 specification for shielded power cable kv UL 1072 medium-voltage power cables. UL 1569 metal clad cables. UL 2225 cables and cable fittings for use in hazardous locations. UL 1309 marine shipboard cable. CSA C68.3. Flame Tests: ICEA T (210,000 BTU/hr). IEEE 383 (70,000 BTU/hr). CSA FT4, IEEE 1202 (70,000 BTU/hr). UL 1072 IEC Category A Compliances: UL Type MV-105, UL File #E UL Type MC-HL, SUN RES, CTUSE, DIR BUR, -40 C, FT4, UL File #E90496 UL Listed Marine Shipboard, UL File #E American Bureau of Shipping (ABS). Listed for CWCMC. Construction: Bare annealed copper conductors per ASTM B3. Compact stranding per ASTM B496 extruded strand shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S and UL mils ethylene propylene rubber (EPR) insulation per ICEA S and UL Extruded insulation shield (EIS) is a thermoset, semi-conducting polymeric layer, free stripping from the insulation per ICEA S and UL Shield is 5 mil annealed bare copper tape with 25% overlap. Phase identification is color-coded polymeric identification tape laid under the shield black, red and blue. Grounding conductors are three split Class B stranded bare annealed copper, sized in accordance with UL 1072 and NEC Article 250. Insulated and grounding conductors are cabled together with non hygroscopic fillers when required. Binder tape is applied over the cabled core. Armor is impervious, continuously welded and corrugated aluminum alloy per UL 1072 and UL Armor conductivity meets the grounding requirements of NEC Article 250. The jacket is flame-retardant, moisture- and sunlight-resistant PVC. Low temperature performance meets ASTM D746 brittleness temperature at or below -40 C. (AWG/ kcmil) Conductors Insulation Thickness (mils) Jacket Thickness (mils) Bare Ground (AWG) Armor Diameter (in.) O.D. (in.) (lbs/ 1000 ft.) ICW635KVEPRPVC ,121 ICW435KVEPRPVC ,418 ICW235KVEPRPVC ,731 ICW135KVEPRPVC ,978 ICW1/035KVEPRPVC 1/ ,259 ICW2/035KVEPRPVC 2/ ,626 ICW4/035KVEPRPVC 4/ ,650 ICW25035KVEPRPVC ,060 ICW35035KVEPRPVC ,045 ICW50035KVEPRPVC ,137 Impervious Continuously Welded (ICW) Armored Power Cable, Shielded, 15kV Application: For use in harsh environments where maximum conductor protection is required. Used for primary power and feeder circuits in commercial and industrial power distribution systems. Approved for use in wet or dry locations at 105 C. For use indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 15,000 volts. UL approved for use at 105 C for continuous operation, 140 C for emergency overload conditions, and 250 C for short circuit conditions. May be used in Class I Division I Hazardous Locations. Specifications: ICEA 70,000 BTU/hr and 210,000 BTU/hr (AWG/ kcmil) Conductors Flame Tests. UL listed, NEC Type MV-105 and Type MC, UL1072. Single conductors are qualified per AEIC CS8. CSA-C22.2 No. 0.3, -40 C Cold Impact Test. UL listed Type CWCMC. IEEE 45/IEEE 1580 (46 CFR Part ) Marine Shipboard Cable. ASTM B-8, B-496. Construction: Soft bare annealed copper conductors, Class B stranding. Semi-conducting conductor shield. EPR insulation with semi-conducting insulation shield. Uncoated 5 mil copper tape shield. Aluminum armor. Flame retardant, sunlight resistant PVC jacket. Insulation Thickness (mils) Jacket Thickness (mils) Copper Ground Wire (AWG) Armor Diameter (in.) O.D. (in.) (lbs./ 1000 ft.) ICW2315KVSEPRPVC ICW1315KVSEPRPVC ICW2315KVSEPRPVC 1/ ICW2315KVSEPRPVC 2/ ICW2315KVSEPRPVC 3/ ICW2315KVSEPRPVC ICW2315KVSEPRPVC ICW2315KVSEPRPVC

51 Connectors and Terminals Type YA-L One Hole HYLUG, Description: Standard barrel lugs for copper cable 600 volts to 35 kv. Copper compression terminals for regular-duty applications. 45 and 90 are available. Contact for more information. Inspection hole ensures proper insertion of cable. Tin-plated. Marked with die index and color code. UL Listed 90 C T T T B L B 45 L B 90 L Conductor SIze Stud Tongue Figure Dimensions (In.) Hole Navy Width AWG/kcmil mm 2 * (In.) (In.) (B) (T) (L) BUYA8CLBOX 37/24 8 Weld 8 AWG 6 Sol BUYA8CL1BOX 37/24 8 Weld 8 AWG 6 Sol / BUYA6CLBOX 6 AWG 1/ BUYA5CLBOX 5 AWG 30 1/ BUYA4CLBOX 4 AWG 40 1/ BUYA4CL6BOX 4 AWG 40 1/ BUYA3CL 3 Str./2 Sol / BUYA2CLBOX 2 AWG / BUYA2CL6BOX 2 AWG / BUYA1CLBOX 1 AWG / BUYA1CL6BOX 1 AWG / BUYA25L6BOX 1/0 AWG 100 1/ BUYA26LBOX 2/0 AWG / BUYA26L6BOX 2/0 AWG / BUYA27LBOX 3/0 AWG 150 1/ BUYA28LBOX 4/0 AWG 200 1/ BUYA29LBOX 250 kcmil 250 1/ BUYA30L 300 kcmil / BUYA31L 350 kcmil / BUYA32L 400 kcmil 400 5/ BUYA34L 500 kcmil 240 5/ BUYA36L 600 kcmil 300 5/ BUYA38L 700 kcmil 5/ BUYA39L 750 kcmil 5/ BUYA40L 800 kcmil 400 5/ BUYA44L 1000 kcmil 500 5/ * The mm 2 conductor sizes listed are the recommendations for Class 2 conductor. The mm 2 conductor size listed is for both Class 2 and Class 5 conductor. For applications greater than 2000 volts, consult cable manufacturer for voltage stress relief instructions. Note: All dimensions shown are for reference only. Aluminum Cord Grips Tuff Seal RSR Series Aluminum Cord Grips are UL Listed and CSA Certified for use in both indoor and outdoor applications to prevent cable pullout, control arc of bend, and to provide a tight seal against environmental elements such as dirt, moisture and coolants. Encompasses conduit sizes from 1/2" to 3" with fittings offered in machined aluminum, nickelplated aluminum, steel, stainless steel, nylon and Valox. Other features include: Designed with a combination tightening surface with hex area and knurled surface. Available with or without wire mesh. Optional embedded Viton O-Ring ensures a watertight and corrosion-resistant seal. Available in NPT, Pg/ISO or metric threads. Provides exceptional corrosion resistance and high wear resistance. Nickel-plated connectors also feature attractive finish similar to that of polished stainless steel. Tuff Seal RSR Cord Grips protect cable from damage and pullout and are used in conduit hubs or knockouts at the point where the electrical cable is to be terminated. Niedax-Kleinhuis IPON Cord Connectors NPT, PG and Metric s Material: Halogen free polyamide, silicone free, neoprene sealing grommet Temperature Range: Permanent -30 C to 100 C (Short term 150 C) Protection Class: IP68, 5 bar / comparable to NEMA 6P Flame Resistance: UL 94 V0, incandescent wire test 850 C to VDE Standard 0471/DIN IEC 695, Part 2-1 Easy to Install Insert your cord into the IPON, tighten the dome-nut and the cable is fixed, centered, sealed and strain relieved. No disassembly required. Versatile 7 NPT fittings (3/8"- 2") cover cable diameters from.157" - 1.7". The IPON is available in NPT, Pg & Metric thread types. (Cable ranges from.177" up to 1.732"). Contact for a complete list of offerings. 49

52 Tools/Accessories Cutting Pliers High Leverage, 8-Inch Diagonal Cutting Pliers, Angled Head Custom US-made tool steel. Induction hardened cutting knives for long life. Hot-riveted joint ensures smooth action and no handle wobble. Short jaws and beveled cutting edges permit close cutting of wire Series pliers available. Cuts ACSR, screws, nails, and most hardened wire. Plastic-dipped handles for comfort and ease of identification. Journeyman pliers available for some styles. State-of-the-art, dual-material handles, which provide a better grip without sacrificing tool strength or durability. Angled head design for easy work in confined spaces. High-leverage design. Rivet is closer to the cutting edge for 36% greater cutting power than other plier designs. Cutting Knives Handle Color Handle Finish Jaw Length Jaw Thickness Jaw Width Overall Length KLD2488 Standard Red Plastic Dipped 13/16" 7/16" 1-3/16" 8-1/16".60 KLJ2488 Standard Red/Black Journeyman 13/16" 7/16" 1-3/16" 8-1/8".61 KLD Standard Royal Blue Plastic Dipped 13/16" 7/16" 1-3/16" 8-1/16".60 KLJ Standard Light-Blue/Black Journeyman 13/16" 7/16" 1-3/16" 8-1/8".67 (lbs.) High Leverage, Heavy Duty, Side Cutting Pliers, 2000 Series Custom, US-made tool steel. Hot-riveted joint ensures smooth action and no handle wobble. Induction hardened cutting knives for long life. Unique handle tempering helps absorb the snap when cutting wire Series pliers available. Cuts ACSR, screws, nails and most hardened wire. Handform handles for full gripping and cutting power. Precision-hardened plier head for on-the-job toughness. Sure-gripping crosshatched knurled jaws. Plastic-dipped handles for comfort and ease of identification. Journeyman pliers available for some styles. State-of-the-art, dual-material handles, which provide a better grip without sacrificing tool strength or durability. Cuts ACSR, screws, nails and most hardened wire. Highleverage design. Rivet is closer to the cutting edge for 46% greater cutting and gripping power than other plier designs. Streamlined design with sure-gripping, cross-hatched knurled jaws Series - Heavy-duty cutting knives. Cuts ACSR, screws, nails and most hardened wire. Features combination polished and black-oxide finish. Handle Color Handle Finish Jaw Length Jaw Thickness Jaw Width Overall Length (lbs.) KLD inch Royal Blue Plastic Dipped 1-9/32" 1/2" 1-1/32" 7-7/8" 0.66 KL inch Royal Blue Plastic Dipped 1-7/16" 5/8" 1-7/64" 8-11/16" 0.85 KL20009NE 9-inch Royal Blue Plastic Dipped 1-19/32" 5/8" 1-1/4" 9-3/8" Inch, High Leverage, Heavy Duty Side Cutting Pliers Custom, US-made tool steel. Hot-riveted joint ensures smooth action and no handle wobble. Induction hardened cutting knives for long life. Unique handle tempering helps absorb the snap when cutting wire Series pliers available. Cuts ACSR, screws, nails and most hardened wire. Handform handles for full gripping and cutting power. Precision-hardened plier head for on-the-job toughness. Sure-gripping, crosshatched knurled jaws. Plastic-dipped handles for comfort and ease of identification. Journeyman pliers available for some styles. State-of-the-art, dual-material handles, which provide a better grip without sacrificing tool strength or durability. Cuts ACSR, screws, nails and most hardened wire. Highleverage design. Rivet is closer to the cutting edge for 46% greater cutting and gripping power than other plier designs. Streamlined design with sure-gripping, cross-hatched knurled jaws. Features combination polished and black-oxide finish. Handle Color Handle Finish Jaw Length Jaw Thickness Jaw Width Nose Type Overall Length (lbs.) KLHD20009NE Light Red Heavy-Duty Oversized Plastic Dipped 1-19/32" 5/8" 1-1/4" New England 9-1/2" 1.15 KLD2139 Dark Blue Plastic Dipped 1-19/32" 5/8" 1-1/4" Square 9-3/8" 1.07 WireMan Side Cutting Pliers Professional quality tools for maximum life and performance Premium quality tool steel provides excellent durability Precision mated blades for easy cutting Smart-Grip textured santoprene handles provide a sure grip and are resistant to perspiration, water, oil and chemicals Smart Grip Handle ends are color coded and have FastFinder letter icons for quick identification Lifetime guarantee ID ID ID ID ID ID ID ID Description 7 Smart Grip Side Cutting 7 Side Cutting 8 Smart Grip Side Cutting 8 Side Cutting 9-1/4 Smart Grip Side Cutting 9-1/4 Side Cutting 9-1/4 Smart Grip Side Cutting w/ Crimp 9-1/4 Side Cutting with Crimp 50

53 Tools/Accessories Cable Cutters MCM Cable Cutting Capacity (kcmil) Standard Cable Cutters Lightweight, yet efficient shear-type cable cutters. Replaceable hook-jaw blades grab and hold cable while shear-cutting action makes clean cuts. Exceptionally strong fiberglass handles with heavy vinyl grips for comfort and slip resistance. Heavy-duty pins in head serve as blade-stops. Jaws are forged tool steel with black-oxide finish for long life. Beveled tips assure positive mating, and hinge on a rugged bolt with a pin-set nut to maintain proper blade tension. Makes a clean, even cut for ease in fitting lugs and terminals. Not designed for cutting steel or ACSR. Length Soft Cable Cutting Capacity (lbs.) KL63060 Handle Color Red Ratcheting Cable Cutters Cleanly cuts copper up to 400 MCM, as well as aluminum and multi-conductor cables up to 600 MCM. Unique ratchet action holds cable tight and allows rapid, straight cuts with minimum effort. Hold-open spring speeds cutting action. Quick-release lever opens blade at anytime during operation. Large, finger-formed handles have limit guards and plastic covering for comfort. Compact, lightweight tool can be locked in closed position for pouch carrying. Not designed for cutting steel or ACSR. Maximum Cable Cutting Capacity 400 copper, 600 aluminum and multi-conductor Overall Length (lbs.) 10" 1.7 KL63041 KL Copper, 750 Aluminum 1000 Copper, 1200 Aluminum Journeyman High Leverage Cable Cutters Cuts up to 4/0 aluminum AWG (no ACSR), 2/0 AWG soft copper and 100-pair 24 AWG communications cable. High leverage for greater cutting power. Precision, onehand shearing action. Handle Color 25-1/2" 1-3/8" " 1-3/4" 8.00 Handle Finish Overall Length (lbs.) KLJ63050 Red/Black Journeyman 9-9/16" 0.98 Ratcheting Cable Cutters Hardened steel blades ensure consistent cuts and long-term durability. Rounded blade design minimizes cable distortion during cutting. Quick release mechanism simplifies blade back-out. Locking mechanism keeps handles closed for easy storage. Molded-in foot provides stability and leverage when making multiple cuts. Ratcheting Cable Cutters High leverage ratchet mechanism for singlehanded cutting of copper and aluminum cables, leaving no burrs or sharp edges. Patented two-step ratchet mechanism requires fewer strokes per cut. Quick release opens blades easily in every cutting position. Precision ratcheting mechanism holds cable tight and allows rapid, straight cuts with minimum effort. Hardened steel cutting blades for lasting strength and sharpness. Plastic covered handles with hand guards for comfort and firm grip. Locking lever keeps handles closed for easy transport, to fit in tool box or bag. Cuts copper and aluminum up to 1000 MCM; frequent use of 750 MCM. Communications Cable Cutting Capacity KL /16" Cutting Capacity Copper and Aluminum, 1000 MCM maximum. Handle Color Compact Ratcheting Cable Cutters Overall Length (lbs.) Red 12-1/8" 1.76 Compact 12" design allows for one-handed use of the ratcheting cutter mechanism, so other hand can position cable to ensure proper cut. Holds cable tight and allows rapid, straight cuts with minimum effort. Quick-release lever opens blade at anytime during operation. Compact, lightweight tool can be locked in closed position for easy transportation in bucket, bag or pouch. ID35053 Maximum Capacity 750 kcmil Hard Drawn Copper and Aluminum KL63601 Cutting Capacity 1000 MCM Aluminum, 600 MCM Copper, 2-1/16" Diameter Communication Cable Handle Color Red Performance Ratchet Cable Cutters Simple, one-hand operation. Two-speed ratchet mechanism adjusts for light/heavy cutting. Well-suited for tight work spaces. Specially designed blade improves cutting capacity. WireMan Cable Cutters Professional quality tool for maximum life and performance. Premium quality steel provides excellent durability Precision mated blades for easy cutting. Smart-Grip textured Santoprene handles provide a sure grip and are resistant to perspiration, water, oil, and chemicals. Maximum Capacity Overall Length Jaw Opening (lbs.) Maximum Capacity Overall Length GR kcmil Copper, 500 kcmil Aluminum 10" 1-7/16" 1.5 ID /0 Copper and Aluminum 9-1/2" 51

54 Tools/Accessories Cable Cutters Long Arm Cable Cutters High strength forged blades for durability. Precision-ground jaws make clean cuts with minimal cable distortion For copper and aluminum only. Replaceable blades. Arm Length Cutting Capacity (kcmil) ID " 250 ID " 500 ID " 1000 Cable Cutter for 2/0 and Smaller Cable Drop-forged high carbon steel construction. Precision ground, hardened cutting edges provide accurate cuts without cable distortion. Designed for maximum leverage. Vinyl coated, comfort-grip handles. Manufacturer lifetime guarantee. ID35052 Hydraulic Cable Cutter The hydraulic cutter cuts in 7 seconds. Jaws slide open quickly to save time between cuts. 11-ton (97 kn) ram powers cutting jaws. Jaws are specially hardened and precision-ground to hold sharpness. Lightweight and easy to use. GR750 Burndy Patriot Hydraulic Self-Contained Cable Cutter The BURNDY 18V battery-powered cutting tool is compact, fast, easy to use and incorporates the latest in battery tool technology. The ergonomic design allows one-hand operation so that the other is free to manipulate the conductor in the proper cutting position. Specialized latch style cutting head that allows interference-free closure for mid-span cuts. Cutter head rotates 180 to get into tight areas easier. Cuts up to 2.45" diameter copper and aluminum cable. Operates on industry standard 18V Ni/MH batteries that eliminate voltage depression or memory issues. Equipped with a high-impact formed carrying case to hold the tool, a tool retention lanyard, a battery charger and two batteries. Provided with a 5-year manufacturer s limited warranty (excluding blades), and 1-year on batteries and charger. Battery Powered Cable Cutter Powered with a state of the art 18V lithium ion (Li-ion) battery. Provides 70% more cycles per charge and faster cycle times. LED light provides the operator with the battery charge and tool maintenance status. Small size makes the ES32L an excellent tool for use inside panel boxes. In-line tool style is lightweight and very easy to control. One trigger controls all tool functions. Cutting head rotates 350. Tools automatically retract when the cutting cycle is complete. Overmolded, tacky grip areas make gripping the tool easier and more comfortable. LED work light illuminates dark work areas. Greenlee battery-powered crimping tools now use bio-degradable oil. Smart chargers control the charging current, charging voltage and battery temperature to maximize battery life. Available with 120V, 12V or 230V battery charger or with 120V or 230V corded adapter in place of batteries and charger. GRES32L11 Gator Plus Battery Powered Cable Cutter Ram automatically retracts after the cut is complete. No need to push a retract lever. Automatically ready to perform the next cut. Two-speed pump advances the ram quickly to start the cut. Cutting blades are specially hardened and precision ground to hold their sharpness. Lightweight and easy to use. Cutting head rotates 360 for making cuts in tight locations, and flips open to make mid-span cuts easy. Includes one-hour battery charger, carrying case and two batteries. Choice of a 120-volt, 230-volt or 12-volt battery charger. BUPATCUT245CUAL18V Cutting Capacity Battery Overall Length (lbs.) GRESG50L11 2" Copper and Aluminum Cable 12V 15-3/4" 10 52

55 Tools/Accessories Crimping and Stripping Tools ILIDT12N Dieless Hand Operated Hydraulic Crimping Tool Pressure system automatically changes crimping force for each connector and size. Seven indent profiles. Automatic two-speed pump. 15 ton maximum crimping force. Head rotates 180. Hinged head. Wire range 1000 kcmil AL/CU - #4 CU. Durable steel carrying case. Journeyman Crimping/Cutting Tool, Non-Insulated/Insulated Connectors Designed to crimp insulated and non-insulated 10 to 22 AWG solderless terminals and connectors. Tapered nose design for working in confined spaces. Contoured thumb area for additional comfort and positive feel. Specially hardened cutter. Hot-riveted joint ensures smooth action and no handle wobble. Large Crimp Tool, Compound Action Crimps 6-4/0 AWG lugs and terminals. All-in-one, integral crimp nest; no removable parts or rotating dies. High-leverage handles and compound-action mechanism for superior mechanical advantage. Ultra-comfortable hand grips for easy use. Adjustment screw allows user to control crimp depth. ID ID Handle Color Handle Finish Overall Length WireMan Multi-Crimp Tool Professional quality tools for maximum life and performance. Premium quality tool steel provides excellent durability. Precision-mated blades for easy cutting Smart-Grip textured Santoprene handles provide a sure grip and are resistant to perspiration, water, oil, and chemicals. Smart- Grip Handle ends are color-coded and have FastFinder letters icons for quick identification. Description (lbs.) KLJ1005 Red/Black Journeyman 9-3/4" 0.84 KL2006 Crimps 6-4/0 AWG lugs, terminals Handle Color Overall Length (lbs.) Black 19-1/2" /4" WireMan Multi-Crimp Tool - Bare Terminals 9-3/4" WireMan Multi-Crimp Tool KL11057 Multi-Purpose 6-in-1 Tool Cleanly shears bolts. Easily cuts and strips wire. Measures stud sizes. Gauges wire sizes. Crimps insulated terminals. Plastic-covered cushioned handles for comfort. KL1000 Handle Color Blue and Red Bolt 4-40, 6-32, 8-32, 10-24, Wire Stripper/Cutter, Solid and Stranded Wire Precision shear-type blades for clean cuts on solid and stranded copper wire. Easy-to-read markings on both sides. Curved handles help reach into confined areas. Wire looping and bending holes. Coil spring provides fast, self-opening action. Precision-ground stripping holes. Stronggripping, serrated nose for easy bending, shaping, and pulling of wire. Screw-shearing holes. Handy closure lock for convenient storage. Doubledipped comfort grips. Overall Length Screw Shearing 7-1/8" 6-32, 8-32 Dual NM Cable Strippers/Cutters 10/2 and 12/2 stripping slots quickly remove outer jacket of Type NM-B non-metallic-sheathed cable. Stripping holes easily remove insulation on 10 and 12 AWG lead wire. Precision staggered blades for square, clean cuts on solid copper wire. Narrow nose fits into tight places. Precision, shear-type blades for square, clean cuts on solid copper wire. Curved handles help reach into confined areas. Strong-gripping, serrated nose for easy bending, shaping and pulling of wire. Wire looping, bending, and screw-shearing holes. Coil spring provides fast, self-opening action. Handy closure lock for convenient storage. Doubledipped comfort grips. Handle Color Overall Length Romex Cable T -Stripper Easy, one-step stripping of outer jacket of NM cable - no slitting required. Versatility to strip, cut and loop conductor wires with precision and ease. Stripping holes for 12 or 14 AWG solid wire. Locking pawl for safe storage. Handle Color Strips and Cuts AWG Solid and AWG Stranded Screw Shearing Overall Length (lbs) KLK1210 Yellow/Orange 7-4/5" 6-32 and ID45248 ID45249 ID45621 Description 14/2 NM Cable T -Stripper 12/2 NM Cable T -Stripper Reflex Super 12/2 & 14/2 NM Cable T -Stripper (lbs) Red 7-3/4" 0.44 (lbs.)

56 Reference Low Smoke Zero Halogen Selection Guide Specifications Product Code M2X M2XH M2XCH FM2XAH FM2XAAH Cable Specs Fire Specs Halogen Free Low Smoke Density Flame Retardant Fire Resistant Physical Specs Oil Resistant (Temporary Contact) Rated Voltage 600v/1kV 600v/1kV 600v/1kV 60/250v 60/250v Test Voltage 3.5kV 3.5kV 3.5kV 1.5kV 1.5kV Working Temperature C -40/90-40/90-40/90-40/90-40/90 Bending Radius (x cable outer diameter by fixed installation) Standard Production Scale Min. - Max. of Cores (p:pairs) p-37p 1p-24p Cross Section(s) (mm 2 ) Cable Construction Conductor IEC 60228, Copper Wire Class Standard (Optional) 5-(2) 2-(5) 2-(5) 2-(5) 2-(5) Core Insulation 2 Mica Tape XLPE XLPO HEPR PUR PVC PVC + Polyamide Pairs and Individual Screen Separating Foil Over Pairs Individual Screen Material 3 Al+d Separating Foil Over Individual Screen Bedding PVC Comp Inner Sheath Flame Retardant Compound Halogen Free Compound Rubber Compound PVC Overall Screen Separating Foil Under Screen Shield/Screen Material 3 CWB Al+d Al+d Separating Foil Under Sheath Outer Sheath 4 PVC (ST2) SHF1 (Black or Gray) SHF1 (Green) Chloroprene Flame Retardant PVC PUR - Standard use - Usage depends on cross section or other features 1 - Production Scale: Indicates the standard production range of core numbers and cross sections for that cable type. Please keep in mind that not every core number within mentioned range may be available, and not all cross sections are available for every core number. See related catalog page(s) for more information. 2 - Core Insulation: HEPR: High-grade Ethylene Propylene Rubber XLPO: Cross Linked Polyolefin PVC + Polyamide: Double Insulation by PVC and Polyamide XLPE: Cross Linked Polyethylene Mica Tape: Copper wire(s) are wrapped by a mica tape under insulation to gain fire resistance 3 - Shield/Screen Material: CWB: Electrolytic plain copper wire braided screen CT: Electrolytic plain copper tape GSWB: Galvanized steel wire braided screen Al + d: Aluminum foil tape with tinned copper drain wire WBT: Water blocking tape 4 - Outer Sheath: PVC (ST2): Flame retardant, oil resistant PVC- based compound SHF1: (HM4-SHF1) HD 604. Halogen free, flame retardant, low smoke, thermoplastic polyolefin- based compound Chloroprene Based Material: Flame retardant and oil resistant PUR: Polyurethane compound 54

57 Reference Low Smoke Zero Halogen Selection Guide Product Code Specifications M2X M2XH M2XCH FM2XAH FM2XAAH Standards Construction DIN DIN DIN IEC 60502/1 IEC 60092/353 IEC 60092/375 IEC 60092/376 Construction, Test and Material VG 88775/66 VG 88777/66 VG 88778/66 Tests and Materials IEC 60092/350 IEC 60092/ EMC DIN EN 50147/1 Flame R. IEC 60332/1-3 Cat A Fire Res. IEC (180min) Smoke Density IEC 60754/1-2, 61034/1-2 DIN EN 50268/1-2 Approval Certificates ABS (American Bureau of Shipping) BV (Bureau Veritas) DNV (Det Nordske Veritas) GL (Germanischer Lloyd) LR (Lloyd s Register) Class NK (Nippon Kaiji Kyokai) RINA (Registro Italiano Navale) RMRS (Russian Maritime Register of Shipping) Türk Loydu (Turkish Lloyd) - Standard use - Usage depends on cross section or other features 1 - Production Scale: Indicates the standard production range of core numbers and cross sections for that cable type. Please keep in mind that not every core number within mentioned range may be available, and not all cross sections are available for every core number. See related catalog page(s) for more information. 2 - Core Insulation: HEPR: High-grade Ethylene Propylene Rubber XLPO: Cross Linked Polyolefin PVC + Polyamide: Double Insulation by PVC and Polyamide XLPE: Cross Linked Polyethylene Mica Tape: Copper wire(s) are wrapped by a mica tape under insulation to gain fire resistance 3 - Shield/Screen Material: CWB: Electrolytic plain copper wire braided screen CT: Electrolytic plain copper tape GSWB: Galvanized steel wire braided screen Al + d: Aluminum foil tape with tinned copper drain wire WBT: Water blocking tape 4 - Outer Sheath: PVC (ST2): Flame retardant, oil resistant PVC- based compound SHF1: (HM4-SHF1) HD 604. Halogen free, flame retardant, low smoke, thermoplastic polyolefin- based compound Chloroprene Based Material: Flame retardant and oil resistant PUR: Polyurethane compound 55

58 Reference Low Smoke Zero Halogen Terminal Selection Cable Part # s mm 2 Terminal Tubes Male CGB Grommet Remke Burndy Thomas & Betts Panduit 1 Hole Std Barrel 2 Hole Std Barrel 1 Hole Std Barrel 2 Hole Std Barrel 1 Hole Std Barrel 2 Hole Long Barrel M2X Construction M2X1x25 1 x 25 M038-3/8" RSR-100 SRB-106 YA2CL YA2CL-2TC TB LCA2 LCD2 M2X1x35 1 x35 M038-3/8" RSR-100 SRB-107 YAV10 YAV10-2TC LCA10 LCD10 M2X1x50 1x 50 M038-3/8" RSR-100 SRB-108 YA25L YA25L-2TC LCA1/0 LCD1/0 M2X1x70 1x 70 M012-1/2" RSR-100 SRB-110 YA27L YA27L-2TC TB LCA3/0 LCD3/0 M2X1x95 1 x 95 M012-1/2" RSR-100 SRB-110 YA29L YA29-2LN LCA250 LCD250 M2X1x120 1 x 120 M012-1/2" RSR-200 SRB-211 YA30L YA30-2LN LCA300 LCD300 M2XH Construction M2XH2x1.5 2 x 1.5 M038-3/8" RSR-100 SRB-106 YAV10 YAV10-2TC LCA10 LCD10 M2XH2x2.5 2 x 2.5 M038-3/8" RSR-100 SRB-107 YAV10 YAV10-2TC LCA10 LCD10 M2XH2x4 2 x 4 M038-3/8" RSR-100 SRB-107 YAV10 YAV10-2TC LCA10 LCD10 M2XH2x6 2 x 6 M038-3/8" RSR-100 SRB-108 YA8CL YA8CL-2TC LCA8 LCD8 M2XH3x1.5 3 x 1.5 M038-3/8" RSR-100 SRB-106 YAV10 YAV10-2TC LCA10 LCD10 M2XH3x2.5 3 x 2.5 M038-3/8" RSR-100 SRB-107 YAV10 YAV10-2TC LCA10 LCD10 M2XH3x4 3 x 4 M038-3/8" RSR-100 SRB-108 YAV10 YAV10-2TC LCA10 LCD10 M2XH3x6 3 x 6 M038-3/8" RSR-100 SRB-108 YA8CL YA8CL-2TC LCA8 LCD8 M2XH3x10 3 x 10 M012-1/2" RSR-100 SRB-110 YA6CL YA6CL-2TC LCA6 LCD6 M2XH3x16 3 x 16 M012-1/2" RSR-200 SRB-211 YA4CL YA4CL-2TC LCA4 LCD4 M2XH3x25 3 x 25 M100-1" RSR-300 SRB-315 YA2CL YA2CL-2TC TB LCA2 LCD2 M2XH3x35 3 x 35 M100-1" RSR-300 SRB-316 YA1CL YA1CL-2TC LCA1 LCD1 M2XH3x50 3 x 50 M100-1" RSR-400 SRB-520 YA25L YA25L-2TC LCA1/0 LCD1/0 M2XH3x70 3 x 70 M /4" RSR-400 SRB-522 YA27L YA27L-2TC TB LCA3/0 LCD3/0 M2XH3x95 3 x 95 M /2" RSR-600 SRB-625 YA29L YA29-2LN LCA250 LCD250 M2XH3x120 3 x 120 M200-2" RSR-600 SRB-627 YA30L YA30-2LN LCA300 LCD300 M2XH3x150 3 x 150 M200-2" RSR-700 SRB-731 YA31L YA31-2LN LCA350 LCD300 M2XH3x185 3 x 185 M200-2" RSR-700 SRB-733 YA32L YA32-2LN LCA400 LCD400 M2XH4x1.5 4 x 1.5 M038-3/8" RSR-100 SRB-107 YAV10 YAV10-2TC LCA10 LCD10 M2XH4x2.5 4 x 2.5 M038-3/8" RSR-100 SRB-107 YAV10 YAV10-2TC LCA10 LCD10 M2XH4x4 4 x 4 M038-3/8" RSR-100 SRB-108 YAV10 YAV10-2TC LCA10 LCD10 M2XH4x6 4 x 6 M012-1/2" RSR-100 SRB-109 YA8CL YA8CL-2TC LCA8 LCD8 M2XH4x10 4 x 10 M012-1/2" RSR-200 SRB-211 YA6CL YA6CL-2TC LCA6 LCD6 M2XH4x16 4 x 16 M034-3/4" RSR-200 SRB-212 YA4CL YA4CL-2TC LCA4 LCD4 M2XH4x25 4 x 25 M100-1" RSR-300 SRB-316 YA2CL YA2CL-2TC TB LCA2 LCD2 M2XH4x35 4 x 35 M /4" RSR-400 SRB-518 YA1CL YA1CL-2TC LCA1 LCD1 M2XH4x50 4 x 50 M /4" RSR-400 SRB-522 YA25L YA25L-2TC LCA1/0 LCD1/0 M2XH4x70 4 x 70 M /2" RSR-600 SRB-625 YA27L YA27L-2TC TB LCA3/0 LCD3/0 M2XH4x95 4 x 95 M200-2" RSR-600 SRB-627 YA29L YA29-2LN LCA250 LCD250 M2XH4x120 4 x 120 M200-2" RSR-700 SRB-731 YA30L YA30-2LN LCA300 LCD300 M2XH4x150 4 x 150 M200-2" RSR-700 SRB-733 YA31L YA31-2LN LCA350 LCD300 M2XH4x185 4x 185 M /2" RSR-700 SRB-737 YA32L YA32-2LN LCA400 LCD400 M2XH7x1.5 7 x 1.5 M038-3/8" RSR-100 SRB M2XH7x2.5 7 x 2.5 M012-1/2" RSR-100 SRB M2XH10x x 1.5 M012-1/2" RSR-100 SRB M2XH10x x 2.5 M012-1/2" RSR-200 SRB M2XH14x x 1.5 M012-1/2" RSR-200 SRB M2XH14x x 2.5 M034-3/4" RSR-200 SRB M2XH20x x 1.5 M034-3/4" RSR-200 SRB M2XH20x x 2.5 M034-3/4" RSR-200 SRB M2XH30x x 1.5 M100-1" RSR-300 SRB M2XH30x x 2.5 M100-1" RSR-400 SRB

59 Reference Low Smoke Zero Halogen Terminal Selection Cable Part # s mm 2 Terminal Tubes Male CGB Grommet Remke Burndy Thomas & Betts Panduit 1 Hole Std Barrel 2 Hole Std Barrel 1 Hole Std Barrel 2 Hole Std Barrel 1 Hole Std Barrel 2 Hole Long Barrel M2XCH Construction M2XCH7x1.5 7 x 1.5 M038-3/8" RSR-100 SRB M2XCH7x2.5 7 x 2.5 M012-1/2" RSR-100 SRB M2XCH10x x 1.5 M012-1/2" RSR-200 SRB M2XCH10x x 2.5 M034-3/4" RSR-200 SRB M2XCH14x x 1.5 M034-3/4" RSR-200 SRB M2XCH14x x 2.5 M034-3/4" RSR-200 SRB M2XCH20x x 1.5 M100-1" RSR-200 SRB M2XCH20x x 2.5 M100-1" RSR-300 SRB M2XCH30x x 1.5 M100-1" RSR-300 SRB M2XCH30x x 2.5 M100-1" RSR-400 SRB FM2XAH Construction FM2XAH1x2x1.5 1 x 2 x 1.5 M038-3/8" RSR-100 SRB FM2XAH1x2x x 2 x.75 M038-3/8" RSR-100 SRB FM2XAH1x2x0.5 1 x 2 x.50 M038-3/8" RSR-100 SRB FM2XAH1x3x1.5 1 x 3 x 1.5 M038-3/8" RSR-100 SRB FM2XAAH Construction with O/A Aluminum Tape and Drain Wire Screen FM2XAAH2x2x1.5 2 x 2 x 1.5 M012-1/2" RSR-100 SRB FM2XAAH2x2x x 2 x.75 M038-3/8" RSR-100 SRB FM2XAAH2x2x0.5 2 x 2 x.50 M038-3/8" RSR-100 SRB FM2XAAH4x2x1.5 4 x 2 x 1.5 M034-3/4" RSR-200 SRB FM2XAAH4x2x x 2 x.75 M012-1/2" RSR-100 SRB FM2XAAH4x2x0.5 4 x 2 x.50 M012-1/2" RSR-100 SRB FM2XAAH6x2x1.5 6 x 2 x 1.5 M100-1" RSR-300 SRB FM2XAAH6x2x x 2 x.75 M034-3/4" RSR-200 SRB FM2XAAH6x2x0.5 6 x 2 x.50 M012-1/2" RSR-200 SRB FM2XAAH10x2x1.5 10x 2 x 1.5 M100-1" RSR-400 SRB FM2XAAH10x2x x 2 x.75 M100-1" RSR-300 SRB FM2XAAH10x2x x 2 x.50 M034-3/4" RSR-200 SRB FM2XAAH12x2x x 2 x 1.5 M100-1" RSR-400 SRB FM2XAAH14x2x x 2 x 1.5 M /4" RSR-400 SRB

60 Reference Low Smoke Zero Halogen Gland Selection Cable Part # s CMP Non Hazardous CMP Hazardous Location Hawke mm 2 Metric Gland Part # NPT Gland Part # Gland Part # NPT M2X Construction M2X1x25 1 x 25 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" M2X1x35 1 x 35 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" M2X1x50 1 x 50 M25 25A2F1RA733 3/4" 20PXSS2K1RA /A 3/4" / 1" M2X1x70 1 x 70 M25 25A2F1RA733 3/4" 20PXSS2K1RA /A 3/4" / 1" M2X1x95 1 x 95 M25 25A2F1RA733 3/4" 20PXSS2K1RA /A 3/4" / 1" M2X1x120 1 x 120 M25 25A2F1RA733 3/4" 20PXSS2K1RA /A 3/4" / 1" M2XH Construction M2XH2x1.5 2 x 1.5 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA /O 1/2" M2XH2x2.5 2 x 2.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2 M2XH2x4 2 x 4 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" M2XH2x6 2 x 6 M25 25A2F1RA733 3/4" 20SPXSS2K1RA /A 3/4" / 1" M2XH3x1.5 3 x 1.5 M20 20SA2F1RA731 1/2 20SPXSS2K1RA /O 1/2" M2XH3x2.5 3 x 2.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" M2XH3x4 3 x 4 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" M2XH3x6 3 x 6 M25 25A2F1RA733 3/4" 20PXSS2K1RA /A 3/4" / 1" M2XH3x10 3 x 10 M25 25A2F1RA733 3/4" 20LPXSS2K1RA /B 1" / 3/4" M2XH3x16 3 x 16 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XH3x25 3 x 25 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" M2XH3x35 3 x 35 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4 / 1" M2XH3x50 3 x 50 M40 40A2F1RA /4" 40PXSS2K1RA /C2 1-1/2" / 1-1/4" M2XH3x70 3 x 70 M50 50SA2F1RA /2" 50SPXSS2K1RA /D 2" / 1-1/2" M2XH3x95 3 x 95 M50 50A2F1RA736 2" 50SPXSS2K1RA /D 2" / 1-1/2" M2XH3x120 3 x 120 M63 63SA2F1RA736 2" 50PXSS2K1RA /E 2-1/2" / 2" M2XH3x150 3 x 150 M63 63SA2F1RA736 2" 63SPXSS2K1RA /E 2-1/2" / 2" M2XH3x185 3 x 185 M63 63A2F1RA /2" 63PXSS2K1RA /E 2-1/2" / 2" M2XH4x1.5 4 x 1.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" M2XH4x2.5 4 x 2.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" M2XH4x4 4 x 4 M25 25A2F1RA733 3/4" 20PXSS2K1RA /B 1" / 3/4" M2XH4x6 4 x 6 M25 25A2F1RA733 3/4" 20LPXSS2K1RA /B 1" / 3/4" M2XH4x10 4 x 10 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4 M2XH4x16 4 x 16 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XH4x25 4 x 25 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" M2XH4x35 4 x 35 M40 40A2F1RA /4" 40PXSS2K1RA /C2 1-1/2" / 1-1/4" M2XH4x50 4 x 50 M50 50SA2F1RA /2" 50SPXSS2K1RA /D 2" / 1-1/2" M2XH4x70 4 x 70 M50 50A2F1RA736 2" 50SPXSS2K1RA /D 2" / 1-1/2" M2XH4x95 4 x 95 M50 50A2F1RA736 2" 50PXSS2K1RA /D 2" / 1-1/2" M2XH4x120 4 x 120 M63 63SA2F1RA736 2" 63SPXSS2K1RA /E 2-1/2" / 2" M2XH4x150 4 x 150 M63 63A2F1RA /2" 63PXSS2K1RA /E 2-1/2" / 2" M2XH4x185 4x 185 M75 75SA2F1RA /2" 75SPXSS2K1RA /F 3" / 2-1/2" M2XH7x1.5 7 x 1.5 M25 25A2F1RA733 3/4" 20SPXSS2K1RA /B 1" / 3/4" M2XH7x2.5 7 x 2.5 M25 25A2F1RA733 3/4" 20PXSS2K1RA /B 1" / 3/4" M2XH10x x 1.5 M25 25A2F1RA733 3/4" 20LPXSS2K1RA /B 1" / 3/4" M2XH10x x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XH14x x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XH14x x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XH20x x 1.5 M25 32A2F1RA733 3/4" 25PXSS2K1RA /C 1-1/4" / 1" M2XH20x x 2.5 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" M2XH30x x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" M2XH30x x 2.5 M40 40A2F1RA /4" 32LPXSS2K1RA /C2 1-1/2"/1-1/4" 58

61 Reference Low Smoke Zero Halogen Gland Selection Cable Part # s CMP Non Hazardous CMP Hazardous Location Hawke mm 2 Metric Gland Part # NPT Gland Part # Gland Part # NPT M2XCH Construction M2XCH7x1.5 7 x 1.5 M25 25A2F1RA733 3/4" 20PXSS2K1RA /B 1" / 3/4" M2XCH7x2.5 7 x 2.5 M25 25A2F1RA733 3/4" 20LPXSS2K1RA /B 1" / 3/4" M2XCH10x x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XCH10x x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XCH14x x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XCH14x x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" M2XCH20x x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" M2XCH20x x 2.5 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" M2XCH30x x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" M2XCH30x x 2.5 M40 40A2F1RA /4" 32LPXSS2K1RA /C2 1-1/2" / 1-1/4" FM2XAH Construction FM2XAH1x2x1.5 1 x 2 x 1.5 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA /O 1/2" FM2XAH1x2x x 2 x.75 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA /O 1/2" FM2XAH1x2x0.5 1 x 2 x.50 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA /0S 1/2" FM2XAH1x3x1.5 1 x 3 x 1.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" FM2XAAH Construction with O/A Aluminum Tape and Drain Wire Screen FM2XAAH2x2x1.5 2 x 2 x 1.5 M25 25A2F1RA733 3/4" 20LPXSS2K1RA /B 1" / 3/4" FM2XAAH2x2x x 2 x.75 M25 25A2F1RA733 3/4" 20PXSS2K1RA /B 1" / 3/4" FM2XAAH2x2x0.5 2 x 2 x.50 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA /O 1/2" FM2XAAH4x2x1.5 4 x 2 x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" FM2XAAH4x2x x 2 x.75 M25 25A2F1RA733 3/4" 20LPXSS2K1RA /B 1" / 3/4" FM2XAAH4x2x0.5 4 x 2 x.50 M25 25A2F1RA733 3/4" 20LPXSS2K1RA /B 1" / 3/4" FM2XAAH6x2x1.5 6 x 2 x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" FM2XAAH6x2x x 2 x.75 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" FM2XAAH6x2x0.5 6 x 2 x.50 M25 25A2F1RA733 3/4" 25PXSS2K1RA /B 1" / 3/4" FM2XAAH10x2x1.5 10x 2 x PXSS2K1RA734 FM2XAAH10x2x x 2 x.75 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1" FM2XAAH10x2x x 2 x.50 M32 32A2F1RA733 1" 32PXSS2K1RA /C 1-1/4" / 1 FM2XAAH12x2x x 2 x 1.5 M40 40A2F1RA /4" 40PXSS2K1RA /C2 1-1/2" / 1-1/4 FM2XAAH14x2x x 2 x 1.5 M40 40A2F1RA /4" 40PXSS2K1RA /C2 1-1/2" / 1-1/4" 59

62 Reference Marine Cable Ampacity Guides Low Smoke Zero Halogen Cable Conversion and Ampacities Ampacity mm 2 AWG/ kcmil Single Conductor Two Conductors at 90 C 3 or 4 Conductors at 90 C / / / Type T/N, Power/Distribution Cable, Multiconductor, 600/1000 Volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated AWG/kcmil 2 Conductors at 90 C* Ampacity 3 Conductors at 90 C* 4 Conductors at 90 C** / / / / * Ampacities based on IEEE Std , Table 25, single bank per hanger at 45 C ambient. Ampacities for other ambient and conductor temperature values were calculated per IEEE , paragraph 3.4 ** Ampacities based on IEEE Std , Table 25, single bank per hanger at 45 C ambient. Adjustments for number of conductors were made per Note on IEEE Std Table 25. Source: CME Wire and Cable. Reprinted with permission. Type T/N, Control Cable, 600/1000 Volts DRILMAR 90, Polyvinyl Chloride/Nylon Insulated Ampacity* of Conductors 18 AWG 16 AWG 14 AWG 12 AWG 10 AWG 90 C 90 C 90 C 90 C 90 C * Ampacities based on IEEE Std. 45, Table 25, single bank per hanger at 45 C ambient. Source: CME Wire and Cable. Reprinted with permission. 60

63 Reference Marine Cable Ampacity Guides Type P, Power/Distribution Cable, Single Conductor, 600/1000/2000 Volts DRILMAR 125-XE, Crosslinked Polyolefin Insulated/CP Jacket Ampacity* AWG/kcmil 125 C 110 C 100 C 95 C / / / / * Ampacities based on IEEE Std , single bank per hanger at 45 C ambient. Ampacities for other ambient and conductor temperature values were calculated per IEEE , paragraph 3.4 Correction Factors (Ambient in SIngle Bank per IEEE 45) Derate Factor For C C C C 1) Double Bank ) 50 C Ambient ) 55 C Ambient ) 40 C Ambient Source: CME Wire and Cable. Reprinted with permission. 61

64 Reference Type P, Power/Distribution Cable, Multiconductor, 600/1000 Volts DRILMAR 125-XE, Crosslinked Polyolefin Insulated/CP Jacket Ampacity AWG/ kcmil 2 Conductors* 3 Conductors* 4 and 5 Conductors** 125 C 110 C 100 C 95 C 125 C 110 C 100 C 95 C 125 C 110 C 100 C 95 C / / / / * Ampacities based on IEEE Std , Table 25, single bank per hanger at 45 C ambient. Ampacities for other ambient and conductor temperature values were calculated per IEEE , paragraph 3.4 ** Ampacities based on IEEE Std , Table 25, single bank per hanger at 45 C ambient. Ampacities for number or conductors were made per Note on IEEE std Table 25. Source: CME Wire and Cable. Reprinted with permission. The Tool Every Electrician Needs. Formulas, tables, charts and diagrams that you can use every day on every job. Now updated for the 2011 NEC. Learn more at summit.com/refbook 62

65 Reference Type P, Control Cable, 600/1000 volts DRILMAR 125-XE, Crosslinked Polyolefin Insulated Ampacity* of Conductors 20 AWG 18 AWG 16 AWG 95 C 100 C 110 C 125 C 95 C 100 C 110 C 125 C 95 C 100 C 110 C 125 C Ampacity* of Conductors 14 AWG 12 AWG 10 AWG 95 C 100 C 110 C 125 C 95 C 100 C 110 C 125 C 95 C 100 C 110 C 125 C * Ampacities based on IEEE Std , Table 25, single bank per hanger at 45 C ambient Source: CME Wire and Cable. Reprinted with permission. 63

66 Reference Certifying Bodies American Bureau of Shipping (ABS) Bureau Veritas (BV) Det Norske Veritas (DNV) Germanischer Lloyd (GL) Lloyd s Register (LR) Class NK (Nippon Kaiji Kyokai) Registro Italiano Navale (RINA) Russian Maritime Register of Shipping (RMRS) Türk Loydu (Turkish Lloyd) 64

67 Index of Manufacturers In addition to wire and cable, s Marine Division offers a full array of marine electrical products. Audio / Visual Signals Sirens / Bells / Horns / Signal Lights Federal Signal Ballasts Fluorescent / HID Universal Lighting Technologies Banding 316 SS Banding / Buckles Hayata Coated 316 SS Banding / Buckles Hayata Batteries Industrial AAA / AA / C / D / Trans / Lantern Rayovac Shipboard Battery Systems / Flooded and Gel Cell Interstate Batteries Cable Glands Marine / Industrial General Duty Gland CMP Hawke Marine / Industrial Class 1, Division 1 & 2 Gland CMP Hawke Cable Termination 250V / 600V / High Voltage Panduit Raychem Thomas & Betts Cable Tray Steel / Aluminum / Marine Rung B-Line Niedax Fiberglass Ladder Chalfant Cables / Industrial MV 90 / IAC / CLX / Control / Instrumentation Okonite MV 90 / IAC / Control / Instrumentation / DLO Southwire MV 90 / IAC / Control / Instrumentation / Welding / DLO AIW Control / Instrumentation / Fiber Optic / IAC Belden Caulking Silicone GE Plastics USCG Approved Fire Stop Caulk Nelson Chemicals Wire Lube / Cleaners Ideal Lubricants / Cleaners / Solvents CRC Conduit Rigid Galvanized Steel LTV Shamrock Allied Rigid Stainless Steel Gibson Rigid Aluminum Easco Indalex Plastic Coated Plastibond Sealtight Anaconda Flexible Anaconda Conduit Fittings Malleable / Cast / Aluminum / Steel Cooper Crouse-Hinds Thomas & Betts Cast Alumimum Cooper Crouse-Hinds Plastic Coated Plastibond Die Cast Steel Cooper Crouse-Hinds Conduit Hubs Cast / Steel / Aluminum / SS Cooper Crouse-Hinds / Myers Cord Grips Aluminum Gland Type Grip Remke Nylon Gland Type Grip Kleinhuis (Niedax) Crane Control Crane Brake Parts Eaton (Cutler-Hammer) Distribution Gear Panel Boards / Power Distribution Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Breakers / Shock & Vibration Eaton (Cutler-Hammer) Westinghouse Electricians Supplies Hand Tools Klein Tools Ideal Emergency Lighting Battery Operated Teledyne / Big Beam Chloride Dual Lite Excide Safety Systems Enclosures NEMA / Steel / Aluminum / SS Cooper Crouse-Hinds Hoffman NEMA / Fiberglass Hoffman Flashlights Mini / D Cell / Lantern Rayovac Bright Star Fuses Glass / 250V / 600 V / High Voltage Mersen (Ferraz Shawmut) European Fuses Mersen (Ferraz Shawmut) Grounding Systems Rods and Fittings Cadweld Heat Shrink Tubing Thick / Thin Wall Tubing Panduit 3M Raychem Industrial Lighting Fixtures Incandescent / Fluorescent / HID Cooper Crouse-Hinds Phoenix Fluorescent Mobern Industrial Reelites Electrical / Pneumatic Cooper Crouse-Hinds Instruments Voltage / Amperes / Continuity Fluke Greenlee Labels / Markers /Signs Cable Marking / Safety Marking Panduit Hayata Weidmuller Lamps Incandescent / Fluorescent / HID Sylvania Miniature Sunray Motor Control MCC / Enclosed Control Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Control / Parts Eaton (Cutler-Hammer Navy) Navigation Light Panels USCG Approved Custom Panels J - Box Pin & Sleeve Plug & Receptacle Amp / Aluminum Cooper Crouse-Hinds Amp / Nylon Stahl Portable Cord SO / SEOW / Type W / GGC Southwire Portable Cord Sets & Parts Cord Caps / Cord Sets Woodhead Hubbell Portable Lighting Hand Lamps / Class 1 Division 1 / Non Hazard Woodhead Portable Cargo Lights Worklights Inc. Safety Switches Amp. / General / Heavy Duty Eaton (Cutler-Hammer) Shipboard Cable Hanger Commercial Cable Hanging Systems R. T. & D Kindorf Victor Commercial and Military Spec Systems R. T. & D Shipboard Communication Integrated Ship Communications Federal Signal Safety and Security Systems Sound Powered Phones Hose McCann Shipboard General Alarm USCG / Navy Approved Brass Bells Hose McCann General Alarm Panels J-Box Shipboard Light Fixtures Incandescent / Fluorescent / HID / Bronze / Aluminum / SS Phoenix Incandescent / Fluorescent / HID / Aluminum / SS Aqua Signal L.C. Doane IRL Shipboard Navigation Lights USCG Approved / Single / Dual Lamp Aqua Signal Shipboard Wiring Devices Switch / Receptacle / Junctions Phoenix Switch / Receptacle & Related Devices Cooper Wiring Devices Strut Systems Slotted / Angled Cooper B-Line Kindorf Tapes Insulating / Bonding / Color Coding 3M Terminal Blocks Din Rail Mount Weidmuller Terminal Tubes 1/2-4 Mil Spec. Nylon Dorn 1/2-4 Brass / Aluminum / Male / Female Electric Supply Terminals / Lugs Mechanical / Compression Panduit Burndy Thomas & Betts Timers Electronic / Mechanical Timers Tork Transformers Marine Duty Dry Type 25kVa - 500kVa Eaton (Cutler-Hammer) Westinghouse Dry Type and Oil Filled / SS Clad Olsun Oil Filled / SS Clad Van Tran Control Power Eaton (Cutler-Hammer) Machine Tool Acme Transformer Dry Type Distribution Acme Transformer Transit Barriers / MCTs Multi Diameter / Fire / Water / Gas Rated Roxtec Tyraps Wire Securing Devices, Nylon & SS Panduit Hayata Thomas & Betts Wire Connectors Wire Nuts Ideal Wing Nuts 3M Wiring Devices Switches / Receptacles Cooper Wiring Devices Woodhead

68 Marine Division

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable

More information

IEEE 1580 TYPE T/N CABLE

IEEE 1580 TYPE T/N CABLE 1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR

More information

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper THHN/THWN-2/MTW/T90 PVC Insulation with Nylon Jacket Solid or Stranded Soft-annealed Uncoated Copper Specifications ASTM (American Society for Testing & Material ASTM B3 Class B, B8 (sizes 6 and larger),

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

TUNNELING POWER CABLES

TUNNELING POWER CABLES TUNNELING POWER CABLES Index 3- Type G-GC (Round) 3/C kv..................... -3 3-5 Type SHD-GC 3/C 5kV........................ -5 3-55 Type SHD-GC 3/C 5kV........................ - 3-0/0/0 Type MP-GC

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable SERVING THE NUCLEAR POWER MARKETS power generating plants original equipment manufacturer storage and waste management facilities

More information

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant Comtran Cable Commercial Premise & Specialty Datacom Products Cat 5e - Cat 6A LSZH & Industrial Ethernet Indoor/Outdoor & Outside Plant Category 6 Commercial Premise Plenum: UL Type CMP Riser: UL Type

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2288626 Master Contract: 184585 Issued to: CMP Products Ltd Glasshouse St. St. Peters Newcastle Upon Tyne, NE6 1BS United Kingdom Attention: Dave Willcock The products

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical

More information

The Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM

The Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM ERIFLEX FLEXIBAR The Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM connections are made by punching directly through the laminates. No lugs to purchase, installation

More information

Cable Glands - American Series - NEC/IEC

Cable Glands - American Series - NEC/IEC Cable Glands - 103 American Series - NEC/IEC 104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable. ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET UL TYPE PLTC UL AWM STYLE 20237 CSA AWM IA/B IIA/B FT1 76 CHOOSE XTRA GUARD 4 FOR: Three Times the Low-Temperature

More information

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 UF103WG250 10/3 WG Uf Cable-250' Southwire Company Catalog Number Manufacturer Description Weight per unit Product Category

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

INFORMATION. Hybrid cables. Description

INFORMATION. Hybrid cables. Description Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description

More information

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE CABLE SOLUTIONS to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE GENERAL CABLE DELIVERS Advanced Reliability, Safety And Sustainability To The Nuclear Power Industry Safe,

More information

Cable Connectors GET CONNECTED

Cable Connectors GET CONNECTED Cable Connectors GET CONNECTED Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for

More information

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification fully shielded Cat.6 patch cable AWG 26/7 S/FTP with PUR cable sheath 1 x RJ45 and 1 x RJ45-IP67-V6

More information

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

PRODUCT CATALOG. Cable glands for Global Applications

PRODUCT CATALOG. Cable glands for Global Applications PRODUCT CATALOG Cable glands for Global Applications 2 CABLE GLANDS FOR HAZARDOUS & INDUSTRIAL APPLICATIONS ABB provides renowned cable protection solutions, including conduit systems and cable glands

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

BFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SEU43500 4-4-4 Seu Cable-500' Southwire Company Catalog Number SEU43500 Manufacturer Southwire Company Description Copper

More information

Electrical connection systems

Electrical connection systems 1 Electrical connection systems Copper tubular cable lugs and connectors 10 Tubular cable lugs 10 Tubular cable lugs for switchgear connections 16 Angle tubular cable lugs 17 Connectors 21 Insulated tubular

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES SUBMERSIBLE PUMP CABLES GENERAL INTRODUCTION Bahra Cables Company was established in 2008 to serve Saudi & GCC Markets. It is based in Bahra industrial city located 25km from Jeddah. Bahra Cables Factory

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

ADE 6F ADE 6F. page 46

ADE 6F ADE 6F. page 46 ADE 6F 6 F U N C T I O N S : D O U B L E C L A M P I N G > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass standard finishing > Optional : stainless steel, aluminium

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE Marine Cables FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for over 165 years, always dedicated to connecting

More information

6000 Series Ethernet Buccaneer

6000 Series Ethernet Buccaneer Thermo-plastic version Patch Cord Flex Connector - Pur Jacket Cable PXP6037 Mates with PXP6033TP type panel mounting Overmoulded patchcords with IP rated connector Supplied with shielded RJ45 plug Single

More information

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme. EcoSystem Cable 369385c 1 01.22.2018 Custom designed cable, for use with EcoSystem components, improves system performance and decreases installation time. Cable is available for sensor connections and

More information

Okoguard -Okoseal Type IEC

Okoguard -Okoseal Type IEC COMPACT STRAND CONSTRUCTION A B C D E F G H Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded Semiconducting EPR Phase

More information

VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS

VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS VFD Lean TR VFD Dual TR Servo VFD Combo DS VFD XLPE TR VFD XLPE 2KV TR SAB s VFD cable series has you covered from fractional to 2 HP drives suitable for industrial

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, PP insulation, PVC jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color coded by

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

Electronic Instrumentation

Electronic Instrumentation Applications Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and

More information

FISCHER FREEDOM TM SERIES

FISCHER FREEDOM TM SERIES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

A driving force in the market place

A driving force in the market place A driving force in the market place Since 1973 Mettex has been producing quality, well engineered and affordable flexible braided wire products for use throughout the electrical industries. We are now

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68

More information

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel ADE 4F 4 F U N C T I O N S : D O U B L E > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass and stainless steel > Optional : aluminium and bronze raw material

More information

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE...

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE... Halogen-free ables E-mail: info@sab.com Web site: www.sab.com Item Description Page hapter A A 146 FRN A A 156 FRN Halogen-free wiring with improved fire performance and extended temperature range 300/500

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, Flamarrest insulation and jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

Ethernet Buccaneer BUCCANEER DATA. bulgin

Ethernet Buccaneer BUCCANEER DATA. bulgin BUCCANEER FOR DATA bulgin Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

Amphenol Cable Glands and Cord Grips Amphenol

Amphenol Cable Glands and Cord Grips Amphenol Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information