UNSHIELDED MULTI CONDUCTOR

Size: px
Start display at page:

Download "UNSHIELDED MULTI CONDUCTOR"

Transcription

1 PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 4. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT 4 and UL 1581 vertical tray flame tests. 5. TEMPERATURE: 105 C 6. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Conductors IN 1000 Ft B B B B B B B B B B B Color Code for two conductor: Black and Red. Color Code for three conductor: Black, Red and White. Anixter Inc

2 PLTC 300 VOLT PVC Insulation 105 C, 300 Volts SHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. ASSEMBLY: Cabled with an overall aluminum mylar shield and stranded tinned copper drain wire. 4. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 5. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests. 6. TEMPERATURE: 105 C 7. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Conductors IN 1000 Ft B B B B B B B B B B B Color Code for two conductor: Black and Red. Color Code for three conductor: Black, Red and White Anixter Inc. 1999

3 PLTC 300 VOLT PVC Insulation 105 C, 300 Volts OVERALL SHIELDED SINGLE AND MULTI PAIR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Stranded, bare copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. PAIRS: Pairs are twisted with a suitable lay to reduce magnetic interference and color coded black and white. Each pair is printed numerically to ensure easy identification. 4. ASSEMBLY: The individual pairs are cabled together to form round completed assembly. Overall aluminum/polyester foil shield with stranded tinned copper drain wire. All cable assemblies include a communication wire for calibration. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black PVC. A rip cord is included for jacket removal. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers. Anixter Inc

4 PLTC 300 VOLT Continued OVERALL SHIELDED SINGLE AND MULTI PAIR PVC Insulation 105 C, 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers Anixter Inc. 1999

5 PLTC 300 VOLT PVC Insulation 105 C, 300 Volts INDIVIDUALLY SHIELDED MULTI PAIR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduits, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. COLOR CODE: Pairs color coded black, red and numbered. 4. ASSEMBLY: Twisted pairs each with an overall aluminum mylar shield and stranded tinned copper drain wire. 5. OVERALL JACKET: Sunlight resistant chrome polyvinyl chloride (PVC) jacket. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft B B B B B B B B B B B B B B B NOTE: Other pair counts available upon request. Anixter Inc

6 PLTC 300 VOLT PVC Insulation 105 C, 300 Volts BELDEN OVERALL SHIELDED MULTI PAIR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. COLOR CODE: Pairs color coded black, red and numbered. 4. ASSEMBLY: Pairs are cabled with an overall aluminum/polyester shield and stranded tinned copper drain wire. 5. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft B B B B B B B B B B B B B B B B B NOTE: Other pair counts available upon request Anixter Inc. 1999

7 PVC Insulation 105 C, 300 Volts PLTC 300 VOLT INDIVIDUAL AND OVERALL SHIELDED MULTI PAIR For use as instrumentation cable inside or outside in control applications. Individually and overall shielded for greater isolation and noise reduction. Suitable for installation in trays, troughs, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Bare copper, Class B, concentric stranded. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. PAIRS: Each pair is twisted with a suitable lay to reduce magnetic interference and color coded black and white. Each pair is also printed numerically to ensure easy identification. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied. 4. ASSEMBLY: The individual pairs are cabled together to form a substantially circular cross-section of the completed assembly. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied overall. All cable assemblies include a communication wire for calibration and a rip cord for jacket removal. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC) jacket. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers. Anixter Inc

8 Continued PVC Insulation 105 C, 300 Volts PLTC 300 VOLT INDIVIDUAL AND OVERALL SHIELDED MULTI PAIR Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers Anixter Inc. 1999

9 PLTC 300 VOLT PVC Insulation 105 C, 300 Volts OVERALL SHIELDED SINGLE AND MULTI TRIAD For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Bare copper, Class B, concentric stranded. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. TRIADS: Each triad is twisted with a suitable lay to reduce magnetic interference and color coded black, white and red. Each triad is also printed numerically to ensure easy identification. 4. ASSEMBLY: The individual triads are cabled together to form a substantially circular cross-section of the completed assembly. Overall aluminum/polyester foil shield with stranded tinned copper drain wire. All cables include a communication wire for calibration and a rip cord for jacket removal. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC). 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 6. TEMPERATURE: 105 C 7. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Triads IN 1000 Ft NOTE: Other triad counts available upon request. Diameters and weights may vary between manufacturers. Anixter Inc

10 PVC Insulation 105 C, 300 Volts PLTC 300 VOLT INDIVIDUAL AND OVERALL SHIELDED MULTI TRIAD For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article CONDUCTORS: Bare copper, Class B, concentric stranded. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. TRIADS: Each triad is twisted with a suitable lay to reduce magnetic interference and color coded black. Each triad is also printed numerically to ensure easy identification. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied. 4. ASSEMBLY: The individual triads are cabled together to form a substantially circular cross-section of the completed assembly. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied overall. All cable assemblies include a communication wire for calibration and a rip cord for jacket removal. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC) jacket. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Triads IN 1000 Ft NOTE: Other triad counts available upon request. Diameters and weights may vary between manufacturers Anixter Inc. 1999

11 PLTC ISA/IEC SP-50 Twisted Pair Orange Jacket 300 Volts BELDEN DATABUS FIELDBUS Bi-directional, digital signal cable used to replace traditional high pair count 4-20ma industrial PLTC cable for fieldbus devices. 1. CONDUCTORS: Tinned, stranded copper. 2. INSULATION: Type A & B Polyethylene (PE). High speed Cellular polyethylene. 3. SHIELD: 100% aluminum/polyester. 4. OVERALL JACKET: Orange polyvinyl chloride (PVC). 5. STANDARDS: Conforms to ISA/IEC SP-50 fieldbus physical layer specification. Meets NEC Article 725 requirements for Type PLTC. Also meets UL and CSA Type CM requirements. Cond. Nominal Belden Size Imped. Capacitance O.D. Anixter Part of Type AWG Stranding Pairs ohms Speed pf/ft. IN B3076F 3076F A 18 7 x kb/s B3077F 3077F B 22 7 x kb/s B3078F 3078F High Speed 22 7 x or 2.5 Mb/s NOTE: European Profibus cable (Belden Part No. 3079F) available upon request. Anixter Inc

12 PLTC Polyolefin Insulation Shielded 600 Volts BELDEN DATATRAY TWINAX For use in most programmable logic control systems (PLCs) and distributed control systems (DCS) in industrial environments. May be installed in cable tray or conduit for a variety of data applications (RS-232, 422 & 485). 1. CONDUCTOR: Annealed, tinned copper. 2. INSULATION: Low attenuation, flame-retardant polyolefin. 3. SHIELD: 100% coverage aluminum/polyester and 55% coverage tinned copper braid. 4. OVERALL JACKET: Dark blue, sunlight resistant, polyvinyl chloride (PVC). 5. STANDARDS: Meets the UL requirements for Type PLTC cable. Meets the UL 1581 vertical tray 70,000 BTU flame test. Meets NEC Article 725 for Class 2 (CL2) circuits and Article 800 for Communications general purpose (CM). Also meets CSA Type CM requirements. Conductor Nominal Belden Size Impedance Capacitance O.D. Anixter Part of Weight Lbs. AWG Stranding Pairs ohms pf/ft. IN 1000 Ft. B3072F 3072F 18 7 x B3073F 3073F 18 7 x B3074F 3074F 18 7 x B3075F 3075F 18 7 x NOTE: Multi pairs/multi conductors available. Wet location rating and Oil Res II jacket available. Any Datatray cable may be armored upon request Anixter Inc. 1999

13 PLTC Aluminum Armor 300 Volts BELDEN INDUSTRIAL AUTOMATION Used in industrial locations requiring extra mechanical protection and system reliability for high speed electronic signalling. 1. CABLE CORE: Cable design configurations for the following PLC manufacturers: Allen Bradley, Square D: Belden Pt. # Allen Bradley: Belden Pt. # , IBM, Foxboro: Belden Pt. # Modicon: Belden Pt. # , GE Fanuc, DEC: Belden Pt. # DEC, Foxboro, Hewlett Packard: Belden Pt. # IBM: Belden Pt. # Honeywell: Belden Pt. # ARMOR: Aluminum interlocked. 3. OVERALL JACKET: Polyvinyl chloride (PVC). 4. STANDARDS: Meets UL ,000 BTU flame test. Meets CSA FT4 flame test requirements. Low acid gas outer jacket per CSA. Conductor Belden Size Inner Jacket Armor Outer Jacket Anixter Part Weight Lbs. UL and CSA AWG IN IN IN 1000 Ft. Designation BA CM BA CM BA CM A-BA CM A-BA CM A-BA CL BA CL DS-BA CL BA CL A-BA * CM BA CM BA CL A-BA CMG BA CMG BA CL BA CL2 * This product is frequently referred to as Allen Bradley armored Blue Hose. Remove 12 from Belden part number to get core part number (e.g., is armored Belden 9463). NOTE: Galvanized steel interlocked armor available upon request. Anixter Inc

14 PVC-Nylon Insulation 90 C, 600 Volts PVC-NYLON/PVC UNSHIELDED AND SHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications and suitable for direct burial. UL Listed for installation in trays, troughs, channels, conduit and wireways in accordance with Articles 318, 340 and 501 of the NEC. TC 600 VOLT 1. CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 90 C polyvinyl chloride (PVC), nylon overcoat. 3. COLOR CODE: Conductors are color coded black, red. 4. ASSEMBLY: Shielded cables are cabled with an overall aluminum/polyester shield and stranded, tinned copper drain wire. 5. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC) jacket, suitable for outdoor use and direct burial. 6. STANDARDS: Meets requirements of UL 1277 and passes the UL 1581 vertical tray flame test. 7. TEMPERATURE: 90 C 8. VOLTAGE: 600 Volts Unshielded Conductor Size Anixter of Weight Lbs. AWG Conductors IN 1000 Ft. B B B B Shielded B B B B Anixter Inc. 1999

15 TC 600 VOLT PVC-Nylon Insulation 90 C, 600 Volts PVC-NYLON/PVC SHIELDED MULTI PAIR For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication. 1. CONDUCTORS: Bare copper, Class B stranded per ASTM B INSULATION: Polyvinyl chloride (PVC) and nylon. Pairs are color coded black and white and numbered. Triads are black, white, red and numbered. 3. SHIELDING: Shields are Aluminum/polyester. Overall drain wire is seven-strand tinned copper. Where applicable, individual drain wires are used, also of seven-strand, tinned copper construction. 4. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 5. STANDARDS: Meets the requirements of UL 1277 and passes the UL 1581 vertical tray flame test. 6. TEMPERATURE: 90 C 7. VOLTAGE: 600 Volts Conductor Overall Jacket Nominal Anixter* Size of Thickness O.D. Weight Lbs. AWG Pairs Triads IN IN 1000 Ft. 2AS-1801POS AS-1801TOS AS-1802POS AS-1803POS AS-1804POS AS-1806POS AS-1808POS AS-1812POS AS-1816POS AS-1824POS AS-1836POS AS-1802SPOS AS-1803SPOS AS-1804SPOS AS-1806SPOS AS-1808SPOS AS-1812SPOS AS-1816SPOS AS-1824SPOS AS-1836SPOS *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers. Anixter Inc

16 TC 600 VOLT Continued PVC-NYLON/PVC SHIELDED MULTI PAIR PVC-Nylon Insulation 90 C, 600 Volts Conductor Overall Jacket Nominal Anixter* Size of Thickness O.D. Weight Lbs. AWG Pairs Triads IN IN 1000 Ft. 2AS-1601POS AS-1601TOS AS-1602POS AS-1603POS AS-1604POS AS-1606POS AS-1608POS AS-1612POS AS-1616POS AS-1624POS AS-1636POS AS-1602SPOS AS-1603SPOS AS-1604SPOS AS-1606SPOS AS-1608SPOS AS-1612SPOS AS-1616SPOS AS-1624SPOS AS-1636SPOS AS-1401POS AS-1401TOS *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers Anixter Inc. 1999

17 TC 600 VOLT XLP Insulation Hypalon Jacket 90 C, 600 Volt XLP/HYPALON SHIELDED MULTI PAIR For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication. 1. CONDUCTORS: Annealed, tinned copper in accordance with ASTM B-3 and B-33. Concentric stranded, Class B per ASTM B INSULATION: Cross-linked polyethylene (XLP), per ICEA S (NEMA WC7). UL rated VW-1 conductors. 3. PAIRS/TRIADS: Each pair/triad is twisted to a 2 in. lay. Color coded: pairs black/white, triads black/white/red with alphanumeric designation (1-ONE). 4. ASSEMBLY: The individually shielded pairs are cabled together with non-hygroscopic and flame retardant fillers as necessary to form a circular cross section of the assembly. A binding tape, when required, shall be applied over cable core. 5. SHIELDING: The entire cable assembly is shielded with polyester backed/aluminum tape and tinned copper drain wire. 6. OVERALL JACKET: Flame retardant Hypalon (CSPE). 7. STANDARDS: Meets the requirements of UL Finished cable passes UL ,000 BTU and ICEA T ,000 BTU flame tests. UL listed as sunlight resistant and rated for direct burial. 8. TEMPERATURE: 90 C 9. VOLTAGE: 600 Volts Conductor Insulation Overall Jacket Nominal Size of Thickness Thickness O.D. Anixter* Weight Lbs. AWG Pairs Triads IN IN IN 1000 Ft. 2RH-1601POS RH-1601TOS RH-1602POS RH-1603POS RH-1604POS RH-1606POS RH-1608POS RH-1612POS RH-1624POS RH-1636POS RH-1602SPOS RH-1603SPOS *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers. Anixter Inc

18 TC 600 VOLT XLP/HYPALON SHIELDED MULTI PAIR Continued XLP Insulation Hypalon Jacket 90 C, 600 Volt Conductor Insulation Overall Jacket Nominal Size of Thickness Thickness O.D. Anixter* Weight Lbs. AWG Pairs Triads IN IN IN 1000 Ft. 2RH-1604SPOS RH-1606SPOS RH-1608SPOS RH-1612SPOS RH-1624SPOS RH-1636SPOS RH-1401POS RH-1401TOS *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers Anixter Inc. 1999

19 TC 600 VOLT EPR Insulation CPE Jacket 90 C, 600 Volt EPR/CPE SHIELDED MULTI PAIR For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication. 1. CONDUCTORS: Annealed, tinned copper in accordance with ASTM B-3 and B-33. Concentric stranded, Class B per ASTM B INSULATION: Ethylene propylene rubber (EPR), per ICEA S UL rated VW-1 conductors. 3. PAIRS/TRIADS: Each pair/triad is twisted to a 2 in. lay. Color coded: pairs black/white, triads black/white/red with alphanumeric designation (1-ONE). 4. ASSEMBLY: The individually shielded pairs are cabled together with non-hygroscopic and flame retardant fillers as necessary to form a circular cross section of the assembly. A binding tape, when required, shall be applied over cable core. 5. SHIELDING: The entire cable assembly is shielded with polyester backed/aluminum tape and tinned copper drain wire. 6. OVERALL JACKET: Flame retardant chlorinated polyethylene (CPE). 7. STANDARDS: Meets the requirements of UL Finished cable passes UL ,000 BTU and ICEA T , 210,000 BTU flame tests. UL listed as sunlight resistant and rated for direct burial. 8. TEMPERATURE: 90 C 9. VOLTAGE: 600 Volts Conductor Insulation Overall Jacket Nominal Size of Thickness Thickness O.D. Anixter* Weight Lbs. AWG Pairs Triads IN IN IN 1000 Ft. 2MR-1601POS MR-1601TOS MR-1602POS MR-1603POS MR-1604POS MR-1606POS MR-1608POS MR-1612POS MR-1624POS MR-1636POS MR-1602SPOS MR-1603SPOS MR-1604SPOS MR-1606SPOS MR-1608SPOS MR-1612SPOS MR-1624SPOS MR-1636SPOS *POS Pair(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. TOS Triad(s) Overall Shield. NOTE: Diameters and weights may vary between manufacturers. Anixter Inc

20 FIBER OPTIC CABLE 62.5µm/125µm Loose Tube Buffer PVC/PVC TRAY CABLE Suitable for outdoor duct, indoor general purpose and aerial use. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray. 1. FIBER SIZE: 62.5µm/125µm 2. CONSTRUCTION: Loose buffer with gel filling and sunlight resistant polyvinyl chloride (PVC) jacket overall. 3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as OFN per NEC Article 770. Max. Min. Attenuation Bandwidth Max. Tensile Load Min. Nom. No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Approx. Anixter of Wt. Lbs. Fibers db/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft IEEE / / IEEE / / IEEE / / IEEE / / IEEE / / IEEE / / IEEE / / Anixter Inc. 1999

21 FIBER OPTIC CABLE 62.5µm/125µm Loose Tube Buffer BELDEN TRAYOPTICS PVC Suitable for indoor or outdoor industrial installations. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray. 1. FIBER SIZE: 62.5µm/125µm 2. CONSTRUCTION: Loose buffer with gel filling, central strength member, inner polyvinyl chloride (PVC) jacket, aramid yarn and orange polyvinyl chloride (PVC) jacket overall. 3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as OFNR (2 12 fiber) or OFN (18 24 fiber) per NEC Article 770. Crush resistance: 500 lbs./inch minimum. Max. Min. Attenuation Bandwidth Max. Tensile Load Min. Nom. Approx. Belden No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Wt. Anixter Part of Lbs. No. Fibers db/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft. BI I / / BI I / / BI I / / BI I / / BI I / / BI I / / BI I / / NOTE: Cable with up to 72 fibers available upon request. Anixter Inc

22 FIBER OPTIC CABLE 62.5µm/125µm Loose Tube Buffer BELDEN TRAYOPTICS CPE Suitable for indoor or outdoor industrial installations. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray. 1. FIBER SIZE: 62.5µm/125µm 2. CONSTRUCTION: Loose buffer with gel filling, central strength member, inner CPE jacket, aramid yarn and orange CPE jacket overall. 3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as OFNR (2 12 fiber) or OFN (18 24 fiber) per NEC Article 770. Crush resistance: 500 lbs./inch minimum Max. Min. Attenuation Bandwidth Max. Tensile Load Min. Nom. Approx. Belden No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Wt. Anixter Part of Lbs. No. Fibers db/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft. BI I / / BI I / / BI I / / BI I / / BI I / / BI I / / BI I / / NOTE: Cable with up to 72 fibers available upon request Anixter Inc. 1999

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET UL TYPE PLTC UL AWM STYLE 20237 CSA AWM IA/B IIA/B FT1 76 CHOOSE XTRA GUARD 4 FOR: Three Times the Low-Temperature

More information

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable SERVING THE NUCLEAR POWER MARKETS power generating plants original equipment manufacturer storage and waste management facilities

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

75 OHM COAXIAL CABLE (RG6)

75 OHM COAXIAL CABLE (RG6) RG6 CABLE (RG6) Drop Cable RG6 UL listed as type CMG for indoor cables. RG-6. 18 AWG copper covered steel with nominal diameter of 0.040 inch (1.02mm). Gas injected foam polyolefin insulation. Nominal

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

TUNNELING POWER CABLES

TUNNELING POWER CABLES TUNNELING POWER CABLES Index 3- Type G-GC (Round) 3/C kv..................... -3 3-5 Type SHD-GC 3/C 5kV........................ -5 3-55 Type SHD-GC 3/C 5kV........................ - 3-0/0/0 Type MP-GC

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

IEEE 1580 TYPE T/N CABLE

IEEE 1580 TYPE T/N CABLE 1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR

More information

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S ADDISON Flame Retardant Tight Buffered Distribution Optic cables MTA-B-C-D-Y Tight Buffer Coating Glass Yarn Ripcord(optional) PVC Outer Sheath APPLICATION This cables are used for interconnection of distribution

More information

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES 37- TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 000 VOLTS FEATURES Highly durable, abrasion-resistant CPE jacket specially designed

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, PP insulation, PVC jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color coded by

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

Interconnect Cable Simplex and Duplex

Interconnect Cable Simplex and Duplex 10.3 Interconnect Cable Simplex and Duplex Tight Buffer & Plenum Rated Patch panels Workstation equipment connections Horizontal distribution in open office environments Interconnect Cables are designed

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Mining and Petrochemical Tray-Rated Fiber Optic Cables Features and Benefits Loose tube construction Stable and highly reliable transmission parameters Waterblocking technology Allows efficient and craft-friendly cable preparation Extra tough double jackets

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, Flamarrest insulation and jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

Electronic Instrumentation

Electronic Instrumentation Applications Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

fiber optic cable Outdoor Cables

fiber optic cable Outdoor Cables fiber optic cable Outdoor Outdoor Cables CST Armored cables for direct-buried applications Product specifications Outdoor Cables OC 1 CST & FRP Armor Applications Ideal for installation where direct-burial

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)... MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9

More information

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding

More information

Product Descriptions

Product Descriptions Product Descriptions Catalog Number Foil Standard Construction - 60% Braid (90% Braid also available) lbs/kft kg/km lbs/kft kg/km F1160BV tape, 60% braid, PVC 59 88 69 103 F1160BVV tape, 60% braid, PVC,

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE PRODUCTS COMMERCIAL BUILDING WIRE & CABLE Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored

More information

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C 10 SOOW 90 C./;SOOW 90 C/11709 Index1.W&C Energy Products////600v Thermoset Jkt'd SOOW 90 C PR33307V2-240057.eps Synthetic rubber insulation Thermoset jacket 90 C, 600 V 1. CONDUCTOR: Bare, annealed copper

More information

E R C. R E R C ; ; W T E C

E R C. R E R C ; ; W T E C WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation

More information

Okoguard -Okoseal Type IEC

Okoguard -Okoseal Type IEC COMPACT STRAND CONSTRUCTION A B C D E F G H Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded Semiconducting EPR Phase

More information

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant. Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60 4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Caledonian Fire Resistant Optic Fiber Cables

Caledonian Fire Resistant Optic Fiber Cables Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They

More information

PVC motor cables unshielded

PVC motor cables unshielded PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,

More information

MIC Unitized Plenum Cables, Fibers

MIC Unitized Plenum Cables, Fibers MIC Unitized Plenum Cables, 36-144 s Features and Benefits Six- or 12-fiber jacketed subunits Quick and easy identification 900 µm TBII Buffered s Easy, consistent stripping All-dielectric cable construction

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

Medium Voltage Power Cables

Medium Voltage Power Cables Medium Voltage Power s Distribution s (CN s) are suitable for use above ground in open air, in conduit in air, directly buried, in underground duct, or aerially when suspended on a messenger wire. CN cables

More information

Introduction. Selection Guide: Shielded Multi-Conductor Computer Cables for RS-232 Applications. Multi Applications Demand Multiple Choice

Introduction. Selection Guide: Shielded Multi-Conductor Computer Cables for RS-232 Applications. Multi Applications Demand Multiple Choice M U L T I - C O N D U C T O R C A B L E S 4.2 Introduction Multi Applications Deand Multiple Choice When the applications are any and the systes different, cable flexibility is vital. Choice eans the ability

More information

INFORMATION. Hybrid cables. Description

INFORMATION. Hybrid cables. Description Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

Automotive Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Caledonian Flame Retardant RS485 Databus Cables

Caledonian Flame Retardant RS485 Databus Cables Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire PVC

More information

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS JANUARY 2015 The Low Friction Advantage in Cable Installation General Cable s new High Speed industrial cable, with Xtra Low Friction

More information

Electronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N

Electronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N Electronic Cable CO N N E C T I N G T E C H N O LO G Y W I T H P E R F O R MA N C E & P R E C I S I O N Our Commitment Our Commitment to our customers is simple - we deliver even when others can t. As

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

MIC Plenum Cables, 2-24 Fibers

MIC Plenum Cables, 2-24 Fibers Features and Benefits 900 µm Buffered Fibers Easy, consistent stripping All-dielectric cable construction Requires no grounding or bonding Flame-retardant jacket Rugged and durable Standards Listings National

More information

Wired for Power Generation

Wired for Power Generation Instrumentation Cables Power Cables Control Cables Communications Cables Specialty Cables Wired for Power Generation Serving the Power Generation Market Wired for Power Generation Coax Low-Voltage Power

More information

Article number: Sheath marking ACE - TKF LTC-S RP 12x SM G.657.A1 (2x6) A-DQ(ZN)B2Y {Batch} {Year} {Length}

Article number: Sheath marking ACE - TKF LTC-S RP 12x SM G.657.A1 (2x6) A-DQ(ZN)B2Y {Batch} {Year} {Length} Description 12x SM G.657.A1 (2x6) The Loose Tube Cable Slim Rodent-Protected () is a non-metallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force.

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

THERMOCOUPLE CABLES THERMOELECTRICITY

THERMOCOUPLE CABLES THERMOELECTRICITY THERMOCOUPLE CABLES THERMOELECTRICITY When a metallic conductor is exposed to a difference of temperature between the two extremities, an electromotive force (emf) is generated by the temperature gradient,

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant Comtran Cable Commercial Premise & Specialty Datacom Products Cat 5e - Cat 6A LSZH & Industrial Ethernet Indoor/Outdoor & Outside Plant Category 6 Commercial Premise Plenum: UL Type CMP Riser: UL Type

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information