VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS

Size: px
Start display at page:

Download "VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS"

Transcription

1 VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS VFD Lean TR VFD Dual TR Servo VFD Combo DS VFD XLPE TR VFD XLPE 2KV TR SAB s VFD cable series has you covered from fractional to 2 HP drives suitable for industrial machinery to factory floor installations. C Cord Grips 44 Kaplan Drive, Fairfield, NJ 74 Toll Free: Tel: Fax: info@sabcable.com

2 VFD Lean TR: Reduced OD, oil resistant and flexible VFD cable VFD Lean TR is an extremely flexible and oil resistant VFD cable. It is designed to perform in VFD applications where increases in voltage can occur due to spikes, harmonics, in-rush current and wave reflection. VFD Lean TR has a foil and tinned copper braid shield for 1% protection against I and RFI. (UL) TC-ER 9C UL MTW 6V Voltage: UL/c(UL): 6 V UR/CSA AWM: 1 V UL WTTC: 1 V Temperature: UR-AWM up to +1C UL/C(UL)/ CSA AWM up to +9C static -C Characteristics: UL / c(ul) FT4 black # d conductors with green/yellow ground Conductor: Class tinned copper stranding Insulation: specially formulated PVC/nylon Screen: Aluminum mylar aluminum tape and tinned copper braiding (8% coverage) Jacket: special sunlight and oil resistant AWG/C 18/4c 16/4c 14/4c 12/4c 1/4c 8/4c 6/4c 4/4c 2/4c inch lbs/mft Amperage 7 C C-2 grounding connector 2-1/ / / / /4 2-C C Oil resistant meeting Oil Res 1 Reduced OD for easier installation Tinned Class stranding for improved flexibility UL TC-ER, UL MTW, UL WTTC & UR AWM c(ul) CIC, CSA AWM FT 4 Maximum Horse Power Rating* 2V V V C-4 grounding connector 4-1/2C M /2C /2C / / / / /2 4- Allowable ampacities are based on not more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of C (211 NEC Table 1.1(B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recoended for based on horse power (HP) and the full load current (FLC) x 1% per NEC Art (A). Amperes (FLC) were determined from NEC Art. 4-.

3 VFD Dual TR: Rugged, oil resistant and flexible VFD cable VFD Dual TR is a flexible VFD cable with an inner jacket for more rugged applications. The inner jacket also helps impede capacitive attraction between the shield and conductors. VFD Dual TR has a foil and tinned copper braid shield for 1% protection against I and RFI. c(ul) CIC 9C FT4 CSA AWM I/II A/B 9C 1V Voltage: UL/c(UL): 6 V UR/CSA AWM: 1 V UL WTTC: 1 V Temperature: UR-AWM up to +1 C UL/C(UL)/ CSA AWM up to +9 C static - C Characteristics: UL / c(ul) FT4 black # d conductors with green/yellow ground Conductor: Class tinned copper stranding Insulation: specially formulated PVC/nylon Screen: Aluminum mylar aluminum tape and tinned copper braiding (8% coverage) Jacket: special sunlight and oil resistant Oil resistant meeting Oil Res 1 Reduced OD for easier installation Tinned Class stranding for improved flexibility UL TC-ER, UL MTW, UL WTTC & UR AWM c(ul) CIC, CSA AWM FT 4 Amperage Maximum Horse Power Rating* AWG/C inch lbs/mft 7 C 9 C 2V 46V 7V /4c /4c /4c /4c /4c /4c /4c /4c /4c C-2 grounding connector C-4 grounding connector / /2C / /2C / / C 4-/ /4 2-C C C / C / C /2 4- Allowable ampacities are based on not more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of C (211 NEC Table 1.1(B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recoended for based on horse power (HP) and the full load current (FLC) x 1% per NEC Art (A). Amperes (FLC) were determined from NEC Art. 4-.

4 Servo VFD Combo DS: Flexible VFD cable with 1 or 2 pairs for brake Servo VFD Combo DS is a flexible VFD cable with 1 or 2 pairs for a brake or temperature sensor when they are part of the motor. The pairs are individually shielded with a drain wire. Servo VFD Combo DS also has a foil and tinned copper braid shield for 1% protection against I and RFI. (UL) TC-ER 9C UL MTW 6V Voltage: UL/c(UL): 6 V UR/CSA AWM: 1 V UL WTTC: 1 V Temperature: UR-AWM up to +1C UL/c(UL)/ CSA AWM up to +9C static -C Characteristics: UL / c(ul) FT4 black # d conductors with green/yellow ground pairs: numbered /6 & 7/8 Conductor: Class tinned copper stranding Insulation: specially formulated PVC/nylon Screen: Aluminum mylar aluminum tape and tinned copper braiding (8% coverage) Jacket: special sunlight and oil resistant AWG/C /4c /4c /4c /4c /4c /4c /4c /4c /4c 814 1/4c /4c 884 8/4c Pair 18/1pr 18/2pr 18/1pr 18/2pr 18/1pr 18/2pr 18/2pr inch lbs/mft 7 C C-2 C connector C 2-2C C 2-/4 2-C C 2-/4 2-C 2-/4 2-C C 2-/4 2-C C 2-1/2 2-/4 2-/4 Amperage 9 C /2 4-/ /4 4-/ /4 4-/ Shielded pair(s) for a brake or temperature sensor all in one cable Oil resistant meeting Oil Res 1 Tinned Class stranding for improved flexibility UL TC-ER, UL MTW, UL WTTC & UR AWM c(ul) CIC, CSA AWM FT 4 Maximum Horse Power Rating* 2V V V C-4 C connector M Allowable ampacities are based on three current carrying conductors plus pairs in a raceway, cable, or direct buried and an ambient temperature of C (211 NEC Table 1.1(B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recoended for based on horse power (HP) and the full load current (FLC) x 1% per NEC Art (A). Amperes (FLC) were determined from NEC Art. 4-. Other dimensions available upon request.

5 XLPE insulated, oil resistant and flexible VFD cable VFD XLPE TR: (UL) TC-ER 9C DRY/WET 6V Voltage: UL/c(UL): 6 V CSA AWM: 1 V UL WTTC: 1 V Temperature: UL/c(UL)/ CSA AWM up to +9 static - C Characteristics: UL / C(UL) FT4 black # d conductors with green/yellow ground C Conductor: Class K tinned copper stranding Insulation: specially formulated XLPE Screen: Aluminum mylar aluminum tape and tinned copper braiding (8% coverage) Jacket: special sunlight and oil resistant AWG/C 16/4c 14/4c 12/4c 1/4c 8/4c 6/4c 4/4c 2/4c VFD XLPE 2KV TR: inch lbs/mft XLPE insulation for excellent capacitance values Oil resistant meeting Oil Res 1 & 2 Tinned Class stranding for improved flexibility UL TC-ER, UL MTW, UL WTTC & Flexible Motor Supply c(ul) CIC, CSA AWM FT 4 Maximum Horse Power Rating* 7 C 9 C V V V Shielded VFD cable rated for 2 KV with syetrical grounds NEW 4/ AWG C TYPE TC-ER RHH OR RHW-2 CDRS Voltage: UL: 2 V Temperature: UL up to +9 C static - C Characteristics: UL FT4 black # d conductors with bare copper syetrical grounds AWG/C Ground 1/c x8 1/-c x6 2/-c x6 /-c x 4/-c x4 -c x2 -c x2 -c x1 XLPE insulation for excellent capacitance values syetrical grounds for better coon mode current flow Copper tape shield (% overlap) for premium I & RFI protection UL TC-ER Conductor: Class B bare copper stranding Insulation: specially formulated XLPE Screen: mil copper tape with % overlap Jacket: special sunlight resistant NEW inch lbs/mft Amperage 7 C C Maximum Horse Power Rating* 2V V V Allowable ampacities are based on not more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of C (211 NEC Table 1.1(B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recoended for based on horse power (HP) and the full load current (FLC) x 1% N EC Art. 4-. per NEC Art (A). Amperes (FLC) were determined from Cord Grips available. See back page for more information.

6 C-2: C grounding gland,,, & Thread C-2 is a nickel plated brass strain relief with integral grounding springs in the gland. It has an IP 68 protection class for excellent protection against dust and water spray. C-2 comes in metric, and thread. Technical Data: Material Contact Spring Clamping Insert Seal O-Ring Protection Class Temperature Range Flaability 2-/8 2-1/2 2-/ C C C C 2-2-C 2-6 Thread Size Clamping Range Ø (min-max) Shield Diameter (Ø min) Brass, Nickel Plated Special Copper Alloy Polyamide 6 V2 Chloroprene (CR) NBR IP 68 - Bar -2 C to +1 C permanent -4 C to +1 C intermittent V2 (according to UL 94) Thread Thread Diameter Length Height Wrenching (TD) (TL) (H) Flats Cap (SW1) inches /8 1/2 / M12X M16X M16X M2X MX MX M2X M2X M4X M4X MX MX M6X Additional thread sizes and colors available upon request

7 C-4: C grounding gland with vibration proof grounding springs Technical Data: Material Brass, Nickel Plated Contact Spring Special Copper Alloy Clamping Insert Polyamide 6 V2 Seal Chloroprene (CR) O-Ring NBR Protection Class IP 68 - Bar Temperature Range -2 C to +1 C permanent -4 C to +1 C intermittent Flaability V2 (according to UL 94) C-4 is a nickel plated brass strain relief with integral grounding springs in the gland that will allow the cable to move without damage to the shield. A cable can be installed from either direction as well. It has an IP 68 protection class for excellent protection against dust and water spray. Thread Size Clamping Range Ø Shield Diameter Thread Diameter (TD) Thread Length (TL) Wrenching Flats Cap (SW1) Height (H) inches (min - max) (Ø min - max) 4-1/4 1/ /8 / /2C 1/ /2 1/ /4 / /4 1 1/ /2 1 1/ M12X M16X C M2X M2X MX M2X M4X MX M6X C M6X

8 VFD LEAN TR VFD XLP XLPEE TR XLPEE 2KV VFD XLP V TR VFD XLP XLPEE TR VFD Lean Lean TR VFD D Dual ual TR Toll T oll F Free: ree: Fax: Fax: info@sabcable.com info@sabcable.com!! " " !! " " *for *for VFD Le Lean an TR vvalue alue iiss co conductor nductor tto o sscreen creen # # 2-/4 2-/4 2-/4 2-/4 2-/4 2-/ # # $ $ $ $ C 2-C 2-C 2-C /2 /2 / / L 4-6L 4-6L 4-6L 4-6L 4-6L C 2-C 2-C 2-C 2-C 2-C 2-C 2-C 2-2C 2-2C 2-4C 2-4C 2-4C 2-4C 2-C 2-C 4-/4 4-/4 4-/4 4-/4 4-/4 4-/ / /4 / /4 / / SServo ervo VFD C ombo DS Combo VFD XLPE TR VFD V TR 2KV XLPE 2K 44 Kaplan Kaplan Dr Drive ive Fairfield, Fair field, NJ

THE RIGHT SOLUTION FOR EVERY APPLICATION

THE RIGHT SOLUTION FOR EVERY APPLICATION VFD ABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLIATION Products Added VFD Lean TR VFD Dual TR Servo VFD ombo DS VFD XLPE TR VFD XLPE 2KV TR Also Included! FLEXIBLE ONTROL ONTINUOUS FLEX SILIONE

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

Cable Accessories. Cord Grips QUALITY - FASTER THAN YOU THINK!

Cable Accessories. Cord Grips QUALITY - FASTER THAN YOU THINK! Cable Accessories Cord Grips QUALITY - FASTER THAN YOU THINK! SAB North America is an industry leader in the design and manufacturing of flexible cables and continuous flex products. For over 50 years

More information

LUTZE Flexible Cable and Wire Management for Industrial Automation. USA Cable Solutions

LUTZE Flexible Cable and Wire Management for Industrial Automation. USA Cable Solutions USA Cable Solutions LUTZE Flexible Cable and Wire Management for Industrial Automation Control Cable Electronic Cable Actuator Sensor Cable BUS and Network Cable Motor Supply, VFD, Servo and Feedback Cable

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

Customer Specification PART NO. V16110

Customer Specification PART NO. V16110 Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. V16110 Construction Diameters (In) 1) Component 1 4 X 1 COND a)

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global

More information

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable

More information

THE RIGHT SOLUTION FOR EVERY APPLICATION

THE RIGHT SOLUTION FOR EVERY APPLICATION CATEGORY CABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLICATION FLEXIBLE CONTROL CONTINUOUS FLEX SILICONE TORSION TRAY VFD DATA SERVO MOTOR EUROAN STYLE BUS/CAT HALOGENFREE REELING SCIAL CUSTOM

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

Variable Frequency Drive (VFD) Cable Solutions

Variable Frequency Drive (VFD) Cable Solutions Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

IEEE 1580 TYPE T/N CABLE

IEEE 1580 TYPE T/N CABLE 1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and

More information

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60 4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)

More information

PVC motor cables unshielded

PVC motor cables unshielded PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,

More information

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

PROFIBUS PA Physical Media Connectivity

PROFIBUS PA Physical Media Connectivity Cordsets Receptacles Terminating resistors Tees Field Wireables P22 P24 P30 P31 P33 Features y Cable that meets the requirements of ISA/SP 50 and PROFIBUS-PA requirements for Type A Cable y All cables

More information

Introduction. Selection Guide: Shielded Multi-Conductor Computer Cables for RS-232 Applications. Multi Applications Demand Multiple Choice

Introduction. Selection Guide: Shielded Multi-Conductor Computer Cables for RS-232 Applications. Multi Applications Demand Multiple Choice M U L T I - C O N D U C T O R C A B L E S 4.2 Introduction Multi Applications Deand Multiple Choice When the applications are any and the systes different, cable flexibility is vital. Choice eans the ability

More information

Energy Supply Systems C-RAIL PROGRAM. KAT a-USA

Energy Supply Systems C-RAIL PROGRAM. KAT a-USA Energy Supply Systems C-RAIL PROGRAM 230 KAT0230-0001a-USA C-Rails and Accessories C-Rails Catalog No. Length l Thickness s [mm] [mm] 023200-6M 6000 023200-4M 4000 023201-6M 6000 023201-4M 4000 2 1.5 6,,

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series

More information

General characteristics and technical data Series MCS

General characteristics and technical data Series MCS MOD M MC MCS VP 100 S Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET UL TYPE PLTC UL AWM STYLE 20237 CSA AWM IA/B IIA/B FT1 76 CHOOSE XTRA GUARD 4 FOR: Three Times the Low-Temperature

More information

THE RIGHT SOLUTION FOR EVERY APPLICATION

THE RIGHT SOLUTION FOR EVERY APPLICATION SAB CABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLICATION FLEXIBLE CONTROL CONTINUOUS FLEX SILICONE TORSION TRAY VFD DATA SERVO MOTOR EUROPEAN STYLE BUS/CAT HALOGENFREE REELING SPECIAL CUSTOM

More information

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications... w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC

More information

Cable Glands & Accessories

Cable Glands & Accessories Cable Glands & Accessories This catalog features ITC s extensive range of liquid-tight, strain relief cord connectors (cable glands) and accessories, including locknuts, sealing washers, plugs, etc. These

More information

CONNECTIVITY SOLUTIONS. for Continuous Flex Applications. ake the right connection

CONNECTIVITY SOLUTIONS. for Continuous Flex Applications. ake the right connection CONNECTIVITY SOLUTIONS for Continuous Flex Applications ake the right connection make the right connection At Lapp Group, we understand the critical role our products play in a wide array of industries

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical

More information

Ethernet Buccaneer BUCCANEER DATA. bulgin

Ethernet Buccaneer BUCCANEER DATA. bulgin BUCCANEER FOR DATA bulgin Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains

More information

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc. Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series

More information

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

6000 Series Ethernet Buccaneer

6000 Series Ethernet Buccaneer Thermo-plastic version Patch Cord Flex Connector - Pur Jacket Cable PXP6037 Mates with PXP6033TP type panel mounting Overmoulded patchcords with IP rated connector Supplied with shielded RJ45 plug Single

More information

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA IP68 Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains IP68 seal to panel

More information

Automotive Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers

More information

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme. EcoSystem Cable 369385c 1 01.22.2018 Custom designed cable, for use with EcoSystem components, improves system performance and decreases installation time. Cable is available for sensor connections and

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

FISCHER FREEDOM TM SERIES

FISCHER FREEDOM TM SERIES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

NTC Thermistor Assemblies

NTC Thermistor Assemblies FEATURES Standard and custom assemblies are available in a variety of configurations Assemblies can conveniently attach to or be an integral part of any system to monitor or control temperature No added

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 310 310.120 CHANGES FROM 2011 TO 2014 CODE ARE IN RED ARTICLE 310 Conductors for General Wiring I. General 310.2 Definitions Electrical Ducts Electrical conduits, or other

More information

CF270.UL.D.

CF270.UL.D. Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:

More information

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)... MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY industrieblick / Fotolia Content page Who we are............................................................................................................

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Microphone and Musical Instrument Cable Overview

Microphone and Musical Instrument Cable Overview B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical

More information

Item Description Page

Item Description Page Cord Grips 2 Item Description Page Chapter Polyamide 6 Cord Grips CG 100 Metric Polyamide cord grip, dome cap, black or gray, metric thread.............. 3 CG 100 PG Polyamide cord grip, dome cap, black

More information

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE EXPERIENCED. RELIABLE. TRUSTED. QUALITY. WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE KalaS headquarters KalaS los angeles 28365 Constellation Road, Unit B KalaSwIRe.COM P 717.336.5575 RELIABLE DEPENDABLE

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Medium Voltage Cables for PermaLife Nuclear Utility Applications Medium Voltage Cables for PermaLife Nuclear Utility Applications The science behind our medium voltage cables. Fig. 1 Fig. 2 non-conducting stress control layer 100% production tested in accordance with

More information

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored Variable Frequency

More information

Mecklenburg County Common Code Defects

Mecklenburg County Common Code Defects Electrical Code Defects Improper Over Current Protection Code Description 310.15 Ampacities for s Rated 0 2000 Volts. (A) General. (1) Tables or Engineering Supervision. Ampacities for conductors shall

More information

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Hook-Up Wire Alpha Wire ALPHA 373

Hook-Up Wire Alpha Wire ALPHA 373 Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 373 The broad range of hookup wire from Alpha means you will find the product exactly suited to

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

Data sheet chainflex CF886

Data sheet chainflex CF886 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Shield foil: Aluminium clad plastic foil 4. Banding: Plastic foil 5. Filling: Plastic yarns 6.

More information

TURCK Network Media Products PROFIBUS -DP

TURCK Network Media Products PROFIBUS -DP TURCK Network Media Products PROFIBUS -DP D1 Industrial Automation PROFIBUS -DP General Specifications PROFIBUS or Process Field Bus is an open communication network, complying with the DIN 19 245 standard.

More information

ENGINEERED CABLE PRODUCTS

ENGINEERED CABLE PRODUCTS ENGINEERED CABLE PRODUCTS DELIVERING DEPENDABILITY FOR MORE THAN HALF A CENTURY Kalas is a full-service manufacturer with over 60 years of experience. We are strategically positioned to deliver quality

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

Metal Cable Glands & Accessories Standard Series pg Stainless Steel Gland. pg. 31 Double Seal Series. pg. 32 Big Size Cable Glands

Metal Cable Glands & Accessories Standard Series pg Stainless Steel Gland. pg. 31 Double Seal Series. pg. 32 Big Size Cable Glands c o n te n ts Plastic Cable Glands & Accessories Standard Series pg. 6-11 Conus Series pg. 12-13 Cable Protection Series pg. 14-18 Lock Nuts pg. 19-21 Blind Stops pg. 22-23 ome Plugs pg. 24 Metal Cable

More information

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SEU43500 4-4-4 Seu Cable-500' Southwire Company Catalog Number SEU43500 Manufacturer Southwire Company Description Copper

More information

EPIC CIRCON M23 Series

EPIC CIRCON M23 Series CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland provides strain relief,

More information

06. har-mik INTERFACE CONNECTORS

06. har-mik INTERFACE CONNECTORS . INTERFACE CONNECTORS Miniature D connectors are a must in various cableto-board applications where space saving and high data transfer rates are required. For the purposes of miniaturization and speed,

More information

E R C. R E R C ; ; W T E C

E R C. R E R C ; ; W T E C WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation

More information

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS JANUARY 2015 The Low Friction Advantage in Cable Installation General Cable s new High Speed industrial cable, with Xtra Low Friction

More information

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see the

More information

EPIC CIRCON M23 Series

EPIC CIRCON M23 Series M23 Series EPIC EPIC CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF270.UL.D For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE PRODUCTS COMMERCIAL BUILDING WIRE & CABLE Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored