1 0T Lever Type Spring Return Plug-in Style Oiltight Switches Range of Operation Reset Reset Switch Without Lever Switch Without Lever and Base Product Selection Standard and Low Operating Torque Models Number of Circuits Lever Movement vs. Contact Operation Clockwise or Clockwise Clockwise or Torque/Force to Operate, Max. 0.9 N m (. lb in) Nominal Operate Contacts, Max. Max. Travel Reset Contacts, Max. Switch w/o Lever 0T-AP Switch w/o Lever and Base 0T-AP 7 0T-A5P 0T-A5P 0.5 N m (5 lb in) 5 Nominal.5 Nominal 0T-FP 0T-FP 9 0T-HP 0T-HP 0.9 N m (. lb in) 0T-AP 0T-AP 7 0T-AP 0T-AP 0.5 N m (5 lb in) 9 0T-HP 0T-HP 0.9 N m (. lb in) 90 0T-AP 0T-AP 7 0T-AP 0T-AP 0.5 N m (5 lb in) 9 0T-HP 0T-AP 0T-ALP 0T-ALP Clockwise 0. N m (.5 lb in) 7 0T-ALP 0T-ALP Clockwise or Clockwise 0T-ALP 0T-ALP 0.5 N m ( lb in) 7 0T-ATP 0T-ATP 0.79 N m (7 lb in) 9 0T-HTP 0T-HTP 0.5 N m ( lb in) 7 0T-ATP 0T-ATP 0.79 N m (7 lb in) T-HTP 0T-HTP 0.5 N m ( lb in) 7 0T-ATP 0T-ATP 0.79 N m (7 lb in) 9.5 0T-HTP 0T-HTP Fluorinated elastomer shaft seal is supplied with these devices. Low operating torque model. Approximate imensions See page 5 -. Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page 5-5. New 5- Visit our website:
2 0T Lever Type Spring Return Plug-in Style Oiltight Switches Approximate imensions [mm (in.)].7 (.7).9 (0.75) 0. (.070).7 (0.).9 (0.07). (0.57) 0. (0.).9 (.75) 9.05 (0.750) (.9) 70. (.7).7 (0.).7 (0.90) 59.5 (.).7 (.9) / - NPT Clearance Holes for # (.7).5 (.7) 7. (.0) / in. NPT Conduit Opening 9. (.5).7 (.5) Plug-in Switch Shipping Wt kg (.5 lb) 7. (0.).5 (0.50) 5. (0.) Front Mounting Hole () #0 - UNF -B Rear Mounting Holes 5. (0.) Front Mounting Hole Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page 5-5. Visit our website: 5-
3 0T Lever Type Maintained Contact and Neutral Position Plug-in Style Oiltight Switches Range of Operation Approximate imensions [mm (in.)] Plug-in Switch Shipping Wt kg (.5 lbs) 5. (.7).9 (0.9) Reset Maintained Contact Models Neutral Position Models Switch Without Lever Reset Switch Without Lever and Base.5 (.) 7.99 (.).7 (0.50) 7.7 (0.) -5. (0.) Holes for Front Mtg..7 (0.5) 9. (.).0 (.) 0.57 (0.) 59. (.) -#0 - UNF -B.0 (0.) eep for Rear Mtg. 7. (0.) Operator Head Conduit.9 (0.7). / in. NPT (.) Conduit Opening Product Selection Maintained Contact Models No. of Circuits Lever Movement vs. Contact Operation Torque to Operate (Max.) Operate Max Travel Reset Switch w/o Lever Switch w/o Lever & Base Clockwise or 0. NSm (.75 lbsin) 0T-AMP 0T -AMP Clockwise or 5 7 From one maintained position to another NSm (. lbsin) 70 0T-AMTP 0T -AMTP Product Selection Neutral Position Models Lever Movement vs. Contact Operation Torque to Operate (Max.) Clockwise Operate Max Travel Reset Switch w/o Lever Switch w/o Lever & Base 0. NSm (.5 lbsin) 0.7 NSm (. lbsin) T-NPTP 0T -NPTP Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page Visit our website:
4 0T Push Type Spring Return Plug-in Style Oiltight Switches Range of Operation Max. Travel Top Push Rod Adjustable Top Push Rod Side Push Rod Top Push Roller Side Push Horizontal Roller Product Selection Number of Circuits Contact Operation Normal Operated Operator Type Top Push Rod Adjustable Top Push Rod Side Push Rod Top Push Roller Side Push Vertical Roller Side Push Horizontal Roller Top Push Rod Adjustable Top Push Rod Side Push Rod Top Push Roller Side Push Vertical Roller Side Push Horizontal Roller Torque/Force to Operate, Max.. N (. lb). N (.7 lb). N (. lb). N (.7 lb). N (5.0 lb).9 N (5. lb). N (5.0 lb).9 N (5. lb) Operate Contacts, Max.. mm (0.057 in.). mm (0. in.). mm (0.057 in.). mm (0. in.). mm (0.057 in.). mm (0. in.). mm (0.057 in.). mm (0. in.) Maximum Travel.0 mm (0. in.) 5.7 mm (0. in.).0 mm (0. in.) 5.7 mm (0. in.).0 mm (0. in.) 5.7 mm (0. in.).0 mm (0. in.) 5.7 mm (0. in.) Reset Contacts, Max. 0.9 mm (0.0 in.).9 mm (0.07 in.) 0.9 mm (0.0 in.).9 mm (0.07 in.) 0.9 mm (0.0 in.).9 mm (0.07 in.) 0.9 mm (0.0 in.).9 mm (0.07 in.) Switch w/o Lever 0T-BP 0T-BAP 0T-CP 0T-P 0T-KP 0T-KP 0T-BTP Switch w/o Lever and Base 0T-BP 0T-BAP 0T-CP 0T-P 0T-KP 0T-KP 0T-BTP 0T-BATP 0T-BATP 0T-CTP 0T-TP 0T-KTP 0T-CTP 0T-TP 0T-KTP 0T-KTP 0T-KTP Modifications and Accessories See page 5-5. Visit our website: New 5-5
5 0T Push Type Spring Return Plug-in Style Oiltight Switches Approximate imensions [mm (in.)].7 (0.) R.7 (0.7) (.9) 70. (.7) 5.7 (.00) 59.5 (.).7 (.9) 5. (0.) Front Mounting Hole () #0 - UNF -B Rear Mounting Holes.7 (0.).50 (.7).5 (.7) 9. (.5).07 (.0). (.5).7 (0.0) R / in. NPT Conduit Opening Switch Body 5. (0.) Front Mounting Hole 5. (.0) 9.5 (0.). (.70) 75. (.97) Max 9.09 (.7) Min 7.7 (0.) ia 7.5 (.) Max. (.) Min 7/ in. Hex Top Push Rod Head Shipping Wt. 0. kg (5 oz) Adjustable Top Push Rod Head Shipping Wt. 0. kg (5 oz).5 (.) (0.) 0.9 (.59) 59. (.) (.0).5 (.) (0.) 50. () Side Push Rod Head Shipping Wt. 0. kg (5 oz) Top Push Roller Head Shipping Wt. 0. kg (5 oz) Side Push Roller Head Shipping Wt. 0. kg (5 oz) Modifications and Accessories See page Visit our website:
6 0T Wobble Stick and Cat Whisker Spring Return Plug-in Style Oiltight Switches Range of Operation Wobble Stick Nylon Extension Wobble Stick Wire Extension Wire Cat Whisker Product Selection Torque to Operator Type Contact Operation Operate (Max.) (Max.) Max Travel (Max.) Complete Switch Switch Without Base Nylon Wobble Stick 0.5 NSm 0T-WSP 0T -WSP Wire Wobble Stick (.5 lbsin) 0T-WSP 0T -WSP Wire Cat Whisker 0.0 NSm ( ozsin) 0T-CWP 0T -CWP These switches should be mounted in such a way that the wobble stick or cat whisker will not be deflected beyond the Maximum Travel position, as this could cause undesirable repetition of contact action on rebound. Operating travels and torque are measured at rigid section of stick or cat whisker. Approximate imensions [mm (in.)].7 (0.).7 (0.7) R (.9) 70. (.7).7 (0.).50 (.7).5 (.7) Switch Body 9. (.5).07 (.0). (.5) 5.7 (.00) 59.5 (.).7 (.9) / in. NPT Conduit Opening 5. (0.) Front Mounting Hole () #0 - UNF -B Rear Mounting Holes 5. (0.) Front Mounting Hole. (5.) 0. (5.). (0.07) O.. Nylon Tubing.05 (5.75).5 ia.. (5.) 0. (). (.9).9 (0.07) ia Cat Whisker Head ShippingWt.0.09kg(oz) Nylon Wobble Stick Head Shipping Wt. 0. kg (7 oz) Wire Wobble Stick Head ShippingWt.0.7kg(oz) Modifications and Accessories See page 5-5. Visit our website: 5-7
7 0T Low Energy Plug-in Style Oiltight Switches Specifications Certifications Environmental Enclosure Type Rating Ambient Temperature [C (F)] Input Voltage C Contact Rating UL Listed, CSA Certified and CE Marked for all applicable directives NEMA,, and P - +0 (0 +0 ) -0 0 (-0 0 ) low temp. model 5 V C 0.0V A load per pole max 0.05V A load per pole min escription Intended for direct connection to PLCs and other low energy circuits, the components and design of these low energy limit switches are optimized for long life. The primary concern of low energy switching is contact contamination. Since low energy loads do not arc or burn the contacts clean, contaminants may cause erratic switch behavior. Rockwell Automation s low energy limit switches are designed with welded gold and silver alloy contacts to provide a protective barrier against surface oxides. A stationary waffle shape contact optimizes contact pressure to stabilize the contact resistance in the region of the micro load. A prism shaped crossbar contact provides high pressure to penetrate foreign particles which could prevent contact closure. These low energy limit switches are suitable for machine connectivity and low voltage facilities. They have a low input voltage of 5 V C with contact ratings of 0.05V A min. and 0.0V A max. per pole. Bulletin 0T low energy limit switches are ideal for applications in which heavy duty pilot ratings, a high degree of versatility and a rugged NEMA Type, and P rating are required. Similar to our full line of standard 0T plug--in style limit switches, our low energy limit switches exist in lever type spring return and push type spring return. Operating heads can be mounted in four positions, 90 apart. In today s age of low energy controls, electromechanical switches are more frequently interfacing directly with low energy circuits. Switching low energy loads presents a unique challenge. Rockwell Automation is perfectly situated to assist you with all your low energy switching needs. Features S S S S S S S S S Welded gold and silver alloy contacts provide a barrier against surface oxides Stationary waffle shape contact reduces the impact of contamination build-up Prism shaped crossbar contact provides high pressure to penetrate foreign particles which could prevent contact closure Snap-acting spanner replicates same reliability performance of our legacy NEMA products Lever type and push type operating styles Plug-in style for ease of wiring and conduit and mini-receptacle wiring options Enclosure rating NEMA, and P UL Listed, CSA Certified and CE Marked for applicable directives 5 V C and 0.05V A min. and 0.0V A max. load per pole Plug-in Style Lever Type Spring Return page 5--9 Push Type Spring Return. page 5--5 Temperature range below 0 C (+ F) is based on the absence of freezing moisture or water. P only applies to lever type, except low torque. 5- Visit our website:
8 0T Low Energy Lever Type Spring Return Plug-in Style Oiltight Switches Range of Operation Reset Reset Switch without Lever Product Selection Standard and Low Operating Torque Models No. of Circuits Contact Operation for Clockwise or Movement Max. Torque to Operate [N m(lb in.)] Max. Travel to Operate (degrees) Maximum Travel (degrees) Max. Reset (degrees) Switch Type Switch w/o Lever 0.9 (.) 90 7 Conduit 0T-AGP All low energy limit switches are designed to operate in an ambient temperature of - 0 C(0 0 F). This 0T -AGPE limit switch is modified for low temperature operation at -0 0 C(-0 0 F). All other specifications are identical to the 0T -AGP. Conduit/Low Temp. 0T -AGPE Identical to 0T -AGP but with pre-wired five-pin mini connector. Same Polarity 5 Mini Connector 0T -AGPJ 0.0 (.) max Conduit/Low Torque 0T-ALGP Recommended standard cordset is 9N--F5AFC--F straight female 5-pin mini to flying leads,. m ( ft) long. For additional cable lengths or styles, see page --. Levers See page 5-0 for a complete listing of operating levers. Visit our website: 5-9
9 0T Low Energy Lever Type Spring Return Plug-in Style Oiltight Switches Approximate imensions [mm (in.)].7 (.7).9 (0.75) 0. (.070).7 (0.).9 (0.07). (0.57) 0. (0.).9 (.75) 9.05 (0.750) (.9).7 (0.90) 70. (.7).7 (0.) 59.5 (.).7 (.9 Clearance Holes for #0-.50 (.7).5 (.7) 7. (.0) /- NPT Conduit Opening 9. (.5).7 (.5) /- NPT 7. (0.) Plug -In Switch Shipping Wt kg (.5 lb).5 (0.50) 5. (0.) Front Mounting Hole () #0- UNF -B Rear Mounting Holes 5. (0.) Front Mounting Hole 5-50 Visit our website:
10 0T Low Energy Push Type Spring Return Plug-in Style Oiltight Switches Range of Operation Side Push Rod Top Push Roller Side Push Vertical Roller Product Selection No. of Circuits Contact Operation Normal Operated Operator Type Force to Operate [NSm(lb] Operate [mm (in.)] Maximum Travel [mm (in.)] Reset [mm (in.)] Side Push Rod. (.) max.. (0.) max. 5.7 (0.). (0.05) max. 0T -CGP Top Push Roller Side Push Vertical Roller. (.) max.. (0.057) max..0 (0.) 0.7 (0.0) 0T-GP. (.) max.. (0.) max. 5.7 (0.). (0.05) max. 0T -KGP Visit our website: 5-5
11 0T Low Energy Push Type Spring Return Plug-in Style Oiltight Switches Approximate imensions [mm (in.)] R.7 (0.7) 70. (.7) 5.7 (.00) 59.5 (.) 5. (0.) Front Mounting Hole () #0- UNF -B Rear Mounting Holes.7 (0.).50 (.7) 9. (.5).07 (.0).7 (0.0) R / in. NPT Conduit Opening 5. (0.) Front Mounting Hole Switch Body.5 (.) 0.57 (0.) 0.9 (.59) Side Push Rod Head Shipping Wt. 0.kg (5oz) 59. (.) (.0) Top Push Roller Head Shipping Wt. 0.kg (5oz).5 (.) (0.) 50. () Side Push Roller Head Shipping Wt. 0.kg (5oz) 5-5 Visit our website:
12 0T Modifications and Accessories Plug-in Style Oiltight Switches Manifold Mount Indicating Light Manifold Mount All two-circuit plug-in limit switches can be supplied with a special terminal base which permits mounting the switch manifold style on a machine base, panel or raceway. As shown above, this base is supplied with a wiring hole and gasket on the back. To order a manifold mount switch, add the letter U to the listed cat. no.. Example: 0T--AP becomes 0T--APU. Indicating Light Bulletin 0T two-circuit plug-in limit switches (except for the cat whisker, wobble stick, and manifold mount devices) can be supplied with an indicating light. To order add the letter N for 0V AC, 50/0 Hz or N5 for 0V AC 50/0 Hz. Example: 0T--AP becomes 0T--APN. The indicating light is internally connected to two isolated terminals in the base assembly allowing the user to wire the light to either the N.O. or the N.C. contact. Switches with an indicating light have a contact rating of NEMA A00. Where an indicator light and a pre-wired 5-pin mini connector are used, the light is pre-wired to the N.C. contact with J wiring and to the N.O. contact with J9 wiring. Indicating lights are not available on -circuit 0T switches. Fluorinated Elastomer Seals To order limit switches with all fluorinated elastomer seals, add the letter V to the end of the listed cat. no. Not available on manifold mount, low operating torque, low temperature or limit switches with an indicating light. To order lever type limit switches with the fluorinated elastomer shaft seal only, add V to the end of the listed cat. no. Base Assembly The limit switch base, including the terminal block, is available as a separate unit per the following table. --Circuit Base... 0T -X7 --Circuit Base with Indicating Light... 0T -X7 N --Circuit Manifold Mount Base... 0T -X7U --Circuit Base... 0T -X Low Temperature Operation Plug-in limit switches are designed to operate in an ambient temperature range of C (0 +0 F), C (0 +0 F) for wobble stick and cat whisker. Special limit switches modified for low temperature operation at C ( F) are available. Temperature ranges below 0 C (+ F) are based on absence of freezing moisture or water. To order, add the letter E to cat. no. Not available on wobble stick, cat whisker or pre-wired cable switches; standard on low torque and maintained devices. Pre-Wired Cable To order factory installed pre-wired type STOOW-A cable for -circuit (5-conductor) and -circuit (9-conductor) switches, add the suffix Y plus the number of feet required. Example: To order an 0T-AP with. m (5 ft) of cable the cat. no. would become 0T--APY5. The standard cable length is. m (5 ft). Extended cable lengths are available in multiples of. m ( ft) only. Mini-Type Receptacles To order a bulletin 0T pre-wired limit switch with a five-pin ( circuit) or nine pin ( circuit) mini connector, add the suffix J or J9 depending on desired wiring (J9 wiring not available for -circuit models). 5-Pin Mini-Type Receptacle Same Polarity 5 5 Same Polarity J Wiring J9 Wiring An appropriate female connector with cable (9N--F5AFC--F) is available on page -- in Connection Systems. 9-Pin Mini-Type Receptacle J Wiring ( J9 wiring not available for circuit) Same Polarity Same Polarity 9 5 Visit our website: An appropriate female connector with cable (9N--F9AF--) is available on page -- in Connection Systems. 5-5
13 0T Specifications Enclosure Rating Pollution egree Certifications Ambient Temperature [C (F)] NEMA, IP5 UL Listed, CSA Certified and CE Marked for applicable directives Nonplug-in limit switches are designed to operate in an ambient temperature range of - +5 (0 +0 ). escription Bulletin 0T limit switches are ideal for applications in which heavy duty pilot ratings, small size, a high degree of versatility and a rugged NEMA Type oiltight construction are desirable. An important factor in the automation of industry, these limit switches are being applied extensively on conveyor systems, transfer machines, automatic turret lathes, milling and boring machines, radial drills, and many other types of modern, high speed production equipment. A wide variety of operating heads and operating levers are available. Operating heads can be mounted in four positions, 90 apart. Features S S S Side rotary, wobble stick, cat whisker, adjustable top and top or side push styles, with or without rollers Rugged construction Proven reliability AC Contact Rating (Maximum per Pole, 50 or 0 Hz, Same Polarity) NEMA Rating esignation A00 AC -5 NonPlug-in Style Max Voltage Make Break C Contact Rating (Maximum per Pole, Same Polarity) Voltage Range Circuit Lever Type Spring Return page Standard and Low Operating Torque Models Lever Type with evicenet page 0--5 Output Spring Return Lever Type Maintained... page 5--5 Contact and Neutral Position Lever Type with Time... page elay Spring Return (-Circuit) Push Type Spring Return. page and Maintained Contact Wobble Stick and Cat... page 5-- Whisker Spring Return -Circuit Vertical Construction Lever Type Spring... page 5-- Return & Maintained Contact Push Type Spring... page 5-- Return & Maintained Contact Wobble Stick and Cat... page 5--5 Whisker Spring Return A Continuous Carrying Current Make Current Rating 0. A 0. A 0. A Temperature range below 0_C(+_F) is based on the absence of freezing moisture or water. See page 5-7 for Extended Temperature Option. VA Break Circuit Horizontal Construction Lever Type Spring Return page 5-- Lever Type Maintained... page 5--7 Contact Push Type Spring... page 5-- Return & Maintained Contact Wobble Stick & Cat... page Whisker Spring Return ual Switch Lever and... page 5--7 Push Types Spring Return Air-Operated Spring Return page 5--7 Modifications and... page 5--7 Accessories Operating Levers Lever Selection... page Visit our website:
14 0T -Circuit Lever Type Spring Return zl Range of Operation Approximate imensions [mm (in.)] NonPlug-in Switch Shipping Wt. 0.5 kg ( lb).7 (0.) 55. (.) Lever Operation with Standard Levers (.) 7. (.) Operating Head Conduit 0T -A 0T -ALW5-5. (0.) ia. Holes for Front Mounting 9. (.). (.5).7 (0.5) 0.5 in. ia. NPT 5. (.7). (0.) Product Selection Standard and Low Operating Torque Models Clockwise or Lever Movement vs. Contact Operation Clockwise Clockwise Lever cannot move counterclockwise Lever cannot move clockwise Torque to Operate (Max.) 0. NSm ( lbsin) 0.5 NSm (.5 lbsin) 0.0 NSm (.5 lbsin) 0.5 NSm (.5 lbsin) 0.0 NSm (.5 lbsin) 0.5 NSm (.5 lbsin) 0.5 NSm ( lbsin) Operate Max Travel Reset.5 0T-A 50 0T-H.5 0T -A T -H.5 0T -A T -H 0 9 0T -L 0T -L Clockwise or 0T -ALW5 Clockwise 0.09 NSm (.5 ozsin) 0T -ALW5 These low operating torque limit switches can only be supplied with cat. no. 0T- W5 rod lever. The rod can easily be formed to meet special application requirements. 0T -ALW5 Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page 5-7. Visit our website:
15 0T -Circuit Lever Type Maintained Contact and Neutral Position Range of Operation Maintained Contact Models Neutral Position Models 0T -AM 0T -NP Product Selection Contact Type Lever Movement vs. Contact Operation Torque to Operate (Max.) Operate Reset Maintained Neutral Position 0.5 NSm (.5 lbsin) T-AM 5 0T-NP From one maintained position to the other. Approximate imensions [mm (in.)]. (.).5.7 (0.) 0.09 (.) 59.5 (.). (0.5).7-5. (0.) ia. Holes for Front Mounting 9. (.). (.5) 59. (.).7 (0.5) 7. (.) 0.5 in. ia. NPT Operating Head Conduit 5. (.7). (0.).7.55 (0.).7 (0.) 9.7 (.55).55 (0.) 7.7 (.) Operating Head.55 (.7) NonPlug-in Switch Shipping Wt. 0.5 kg ( lb) 0T -AM NonPlug-in Switch Shipping Wt. 0.5 kg ( lb) 0T -NP Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page Visit our website:
16 0T -Circuit Lever Type with Time elay Spring Return 0T -RT with 0T -W Lever Product Selection Lever Movement vs. Contact Operation Torque to Operate (Max.) Operate Contact (Max.) Overtravel Max Travel On-elay Off-elay Clockwise Lever cannot move counterclockwise Lever cannot move clockwise 0. NSm ( lbsin) 5 5 Approx. 90 0T -RT 0T -RT 0T -RT 0T -RT 0T -R7T 0T -R5T 0T -RT 0T -RT Required for Timing Accuracy. The time delay is adjustable from seconds ± 5%. Contacts are rated for A, 0V AC maximum. The lever travel must be faster than the timing setting. Time delay occurs after lever is moved to operated position Time delay occurs after lever is moved from operated to normal position Visit our website:
17 0T Approximate imensions [mm (in.)]. (.5).5 9 (0.75) ia.. (.) 5..9 (.7) (.0) (.75) (.5) Time elay Switch with 0T -W Lever Shipping Wt kg ( lbs) Conduit. (.) 5. (.).5 () 5.5 (0.) ia. Mounting Holes 0.5 ia. NPT. (.5).7 (.) Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page Visit our website:
18 0T -Circuit Push Type Spring Return and Maintained Contact Top Push Rod Adjustable TopPushRod Side Push Rod Top Push Roller Side Push Roller Side Push Rod Maintained Range of Operation Spring Return Maintained Normal Operated Product Selection Operator Type TopPushRod Adjustable Top Push Rod TopPushRoller Contact Operation Normal Operated Force to Operate (Max.) 5. N (.5 lb) Operate.9 mm (0.075 in.) 5. mm (0.0 in.) Reset 0. mm (0.00 in.) 0T-B 0T -BA Side Push Rod 0T-C Side Push Vertical Roller 0.0 N. mm 5.5 mm.5 mm (.5 lb) (0.5 in.) (0. in.) (0.057 in.) 0T-K Side Push Horizontal Roller 0T -K.7 mm 5.0 mm Maintained Contact 5. N 5.9 mm (0.9 in.) (0.09 in.) Side Push Rod ( lbs) (0.5 in.) Nominal Nominal 0T -CM 0T- Modifications and Accessories See page 5-7. Visit our website:
19 0T -Circuit Push Type Spring Return and Maintained Contact Approximate imensions [mm (in.)] 7. (.) 59. (.) Operating Head Conduit -5. (0.), ia. Holes for Front Mtg. 9. (.). (.5).7 (0.5) 0.5 ia. NPT 5. (.7). (0.) NonPlug-in Switch Shipping Wt. 0.5 kg ( lb) 9.5 (0.).9 (.7).0 (0.) 7.5 (.) (Max.. ) (.) (Min.) (.0) 0T -B Top Push Rod Head Shipping Wt. 0. kg (.5 oz) 0T -BA Adjustable Top Push Rod Head Shipping Wt. 0. kg (.5 oz) 0T - Top Push Roller Head Shipping Wt. 0. kg (.5 oz).7 (.). (.5).7 (.).7 (.) 0. (.9).7 (.).5 (.9) (0.) (0.). (0.) 0T -C Side Push Rod Head Shipping Wt. 0. kg (.5 oz) 0T -K Side Push Roller Head Shipping Wt. 0. kg (.5 oz) 0T -CM Maintained Side Push Rod Head Shipping Wt..5 oz (0. kg) Modifications and Accessories See page Visit our website:
20 Range of Operation Limit Switches 0T -Circuit Wobble Stick and Cat Whisker Spring Return Wobble Stick Nylon Extension Wobble Stick Wire Extension Cat Whisker Product Selection Operator Type Contact Operation Torque to Operate (Max.) Operate Reset Nylon Wobble Stick Wire Wobble Stick Wire Cat Whisker 0.5 NSm (.5 lbsin) 0.0 NSm ( ozsin) 9 0 0T-WS 0T -WS 0T -CW Operating travels and torque are measured at rigid section of stick or cat whisker. Approximate imensions [mm (in.)] -5. (0.), ia. Holes for Front Mounting 9. (.). (.5) 7. (.) 59. (.).7 (0.5) 0.5 in. ia. NPT Operating Head Conduit 5. (.7). (0.) 5. (5.) (.5).9 (0.07) ia. (0.07) O.. Nylon Tubing 7 (5) 5.59 (0.) NonPlug-in Switch Shipping Wt. 0.5 kg ( lb) Z -0 Nylon Wobble Stick Head Shipping Wt. 0. kg (.5 oz) Z - Wire Wobble Stick Head Shipping Wt. 0.9 kg (5.5 oz) Z -5 Cat Whisker Head Shipping Wt. 0.0 kg ( oz) Modifications and Accessories See page 5-7. Visit our website: 5-
21 0T Vertical -Circuit Push Type Spring Return & Maintained Contact Range of Operation Approximate imensions [mm (in.)] Switch Without Lever.7. (.5) 9 (0.75) ia. 7.7 (0.).7 (.) 57.9 (.) 5. (.7) Operating Head.9 (0.7) 0. (.0) Product Selection Clockwise or Clockwise Lever Movement vs. Contact Operation Torque to Operate (Max.) 0. NSm ( lbsin) 0. NSm ( lbsin) 0.0 NSm (.5 lbsin) 0. NSm ( lbsin) 0.0 NSm (.5 lbsin) 0. NSm ( lbsin) Operate.9 (.75) 5.97 (.) (0.9) (0.75) ia. NPT Conduit.7 (.) 9 (0.75) Circuit NonPlug-in Switch with 0T -W Lever Shipping Wt kg (.5 lb) Reset 0T -AT T -HT 0T -AT T -HT 0T -AT T -HT Clockwise Lever cannot move counterclockwise Lever cannot move clockwise 0.5 NSm ( lbsin) 9 0T -LT 0T -LT Maintained Contact Clockwise or NSm ( lbsin) 75 From one maintained position to the other 50 0T -AMT Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page Visit our website:
22 0T Vertical -Circuit Push Type Spring Return & Maintained Contact Top Rod Range of Operation Adjustable Top Push Rod Side Rod Top Roller Side Roller Side Rod Spring Return Maintained Normal Operated Product Selection Operator Type Contact Operation Normal Operated Force to Operate (Max.) Operate Max Travel Reset Catalog Number TopPushRod Adjustable Top Push Rod Side Push Rod TopPushRoller Side Push Vertical Roller Side Push Horizontal Roller Maintained Contact Side Push Rod. N (5.5 lb).9 N (.5 lb). N (5.5 lb).9 N (.5 lb). N ( lb). mm (0.0 in.).9 mm (0.55 in.) Nominal.0 mm (0. in.) 5.9 mm (0.5 in.). mm (0.0 in.). mm (0.09 in.). mm (0.0 in.). mm (0.09 in.) 5.0 mm (0.0 in.) Nominal 0T -BT 0T -BAT 0T -CT 0T -T 0T -KT 0T -KT 0T -CMT These devices are not available with fluorinated elastomer seals or neon indicating lights. Modifications and Accessories See page 5-7. Visit our website: 5-
23 0T Vertical -Circuit Push Type Spring Return & Maintained Contact Approximate imensions [mm (in.)].7 (.) Operating Head 0. (.).9 (.75) 7.5 (0.9) ia. (0.75) NPT 5.97 (.).7 (.) NonPlug-in Switch Shipping Wt kg (.5 lb) 9.5 (0.).9 (.7) 0T -BT Top Push Rod Head Shipping Wt. 0. kg (.5 oz).0 (0.) 7.5 (.) Max. (.) Min Adjustable Top Push Rod Head for 0T -BAT Shipping Wt. 0. kg (.5 oz).7 (.) (0.). (.5) 0T -CT Side Push Rod Head Shipping Wt. 0. kg (.5 oz).7.7 (.).7 (.) 0. (.9).7 (.).5 (.9) 5.5 (.0) 0T -T Top Push Roller Head Shipping Wt. 0. kg (.5 oz) Not a saleable item T -KT 0T -KT Side Push Roller Head Shipping Wt. 0. kg (.5 oz) (0.) 0T -CMT Maintained Side Push Rod Head Shipping Wt. 0. kg (.5 oz). (0.) Modifications and Accessories See page Visit our website:
24 Range of Operation Limit Switches 0T Vertical -Circuit Wobble Stick and Cat Whisker Spring Return Travels Are Measured at Rigid Section of Stick or Whisker Wobble Stick Cat Whisker Product Selection Operator Type Contact Operation Torque to Operate (Max.) Operate Max Travel Reset Nylon Wobble Stick Wire Cat Whisker 0.79 NSm (7 lbsin) 9 0T -WST 0T -WST These switches should be mounted in such a way that the wobble stick or cat whisker will not be deflected beyond the Maximum Travel position, as this could cause undesirable repetition of contact action on rebound. Approximate imensions [mm (in.)] 0. (.).7 (.) Operating Head 5. (5.) (.5).9 (0.07) ia.9 (.75) 7.5 (0.9) 5.97 (.) 0.75 ia. NPT 9 (0.75).7 (.) NonPlug-in Switch Shipping Wt. 0.5 kg ( lb) Z -0 Nylon Wobble Stick Head Shipping Wt. 0. kg (.5 oz) Z - Wire Wobble Stick Head Shipping Wt. 0.9 kg (5.5 oz) Modifications and Accessories See page 5-7. Visit our website: 5-5
25 0T Horizontal -Circuit Lever Type Spring Return Range of Operation No Contact Movement Lever Operation When Standard Levers Are Used Product Selection Lever Operation When 0T -W7 and W One-Way Levers Are Used Switch Without Lever Clockwise or Lever Movement vs. Contact Operation Torque to Operate (Max.) 0. NSm ( lbsin) 0. NSm ( lbsin) Operate Max Travel Reset 0T -ATH 50 0T -HTH Clockwise NSm (.5 lbsin) 0. NSm ( lbsin) 0T -ATH 50 0T -HTH NSm (.5 lbsin) 0. NSm ( lbsin) 0T -ATH 50 0T -HTH Clockwise Lever cannot move counterclockwise Lever cannot move clockwise NSm ( lbsin) 0 9 0T -LTH 0T -LTH Approximate imensions [mm (in.)] Conduit Position B Conduit positions for modifications S, S, S (0.75). (.5) Conduit Position A 7. ().9 (.5).5 (.75) 5. (.7) 9 (0.75) ia. 7. ().5.9 (.5).5 9 (0.75) ia. NPT 5.9 (.) Operating Head Conduit.0 (.).7 (0.) 0. (0.) -Pole Horizontal Switch with 0T -W Lever Shipping Wt. 0.9 kg ( lbs) Conduit Position C Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page Visit our website:
26 0T Horizontal -Circuit Lever Type Maintained Contact Range of Operation Switch Without Lever Product Selection Lever Movement vs. Contact Operation Torque to Operate (Max.) Operate Reset Clockwise or NSm ( lbsin) 70 From one maintained position to the other 5 0T -AMTH Approximate imensions [mm (in.)] 9 (0.75) ia. 5.9 (.) 5. (.7).7 (0.).7. (.5).5 7. ().9 (.5) Operating Head -Pole Horizontal Switch with 0T -W Lever Shipping Wt. 0.9 kg ( lb) Conduit 7. ().9 (.5).5 9 (0.75) ia. NPT 0. (.9). (0.9) Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page 5-7. Visit our website: 5-7
27 0T Horizontal -Circuit Push Type Spring Return & Maintained Contact Top Push Rod Range of Operation Adjustable Top Push Rod Side Push Rod Top Push Roller Side Push Roller Side Push Rod Maintained Contact Spring Return Maintained Normal Operated Product Selection Operator Type Normal Contact Operation Operated Force to Operate (Max.) Operate Max Travel Reset TopPushRod Adjustable Top Push Rod Top Push Roller Side Push Rod Side Push Vertical Roller Side Push Horizontal Roller Maintained Contact Side Push Rod N (5.5 lbs). N ( lbs). mm (0.09 in.). mm (0.09 in.).7 mm (0.9 in.) Nominal 5.9 mm (0. in.) 5.9 mm (0.5 in.). mm (0.0 in.). mm (0.0 in.) 5.0 mm (0.09 in.) Nominal 0T -BTH 0T -BATH 0T -TH 0T -CTH 0T -KTH 0T -KTH 0T -CMTH Modifications and Accessories See page Visit our website:
28 Approximate imensions [mm (in.)] Limit Switches 0T Horizontal -Circuit Push Type Spring Return & Maintained Contact 7. ().9 (.5) Operating Head 7. ().9 (.5).5 9 (0.75) ia. NPT -Pole Horizontal Switch Base Shipping Wt. 0.9 kg ( lb) Conduit 0. (.9). (0.9) 9.5 (0.).9 (.7) Z -9 Top Push Rod Head Shipping Wt. 0. kg (.5 oz).0 (0.) 7.5 (.) Max. (.) Min Adjustable Top Push Rod Head for 0T -KTH Shipping Wt. 0. kg (.5 oz).7 (.) (0.). (.5) Z -5 Side Push Rod Head Shipping Wt. 0. kg (.5 oz) (.0).7 (.) (.) 0. (.9) (0.).7 (.).5 (.9). (0.) Z -9 Top Push Roller Head Shipping Wt. 0. kg (.5 oz) Not a saleable item. Z - Side Push Roller Head Shipping Wt. 0. kg (.5 oz) Z - Maintained Side Push Rod Head Shipping Wt. 0. kg (.5 oz) Modifications and Accessories See page 5-7. Visit our website: 5-9
29 0T Horizontal -Circuit Wobble Stick & Cat Whisker Spring Return Range of Operation Travels Are Measured at Rigid Section of Stick Wobble Stick Cat Whisker Product Selection Operator Type Contact Operation Torque to Operate (Max.) Operate Reset Nylon Wobble Stick Wire Cat Whisker NSm (7 lbsin) 9 0T -WSTH 0T -WSTH These switches should be mounted in such a way that the wobble stick or cat whisker will not be deflected beyond the Maximum Travel position, as this could cause undesirable repetition of contact action on rebound. Approximate imensions [mm (in.)] 7. ().9 (.5) Operating Head 5. (5.) (.5).9 ia (0.07) Conduit.9 (.5) 7. ().5 9 (0.75) ia. NPT -Pole Horizontal Switch Shipping Wt. 0.9 kg ( lb) 0. (.9). (0.9) Z -995 Nylon Wobble Stick Head Shipping Wt. 0. kg (.5 oz) Z -09 Wire Wobble Stick Head Shipping Wt. 0.9 kg (5.5 oz) Modifications and Accessories See page Visit our website:
30 0T ual Switch Lever and Push Types Spring Return ual Switch with 0T -W Levers Product Selection Left Hand Switch Right Hand Switch 0T- A 0T- H 0T- A 0T- A 0T- C 0T- 0T -A 0T -A 0T -AH 0T -AA 0T -AA 0T -AC 0T -A 0T -H 0T -HA 0T -H 0T -HA 0T -HA 0T -HC 0T -H 0T -A 0T -AA 0T -AH 0T -A 0T -AA 0T -AC 0T -A 0T -A 0T -AA 0T -AH 0T -AA 0T -A 0T -AC 0T -A 0T -C 0T -CA 0T -CH 0T -CA 0T -CA 0T -C 0T -C 0T - 0T -A 0T -H 0T -A 0T -A 0T -C 0T - Ordering Information Refer to limit switch listings on pages 5-55 and 5-59 determine which units and levers are correct for the desired application. Select left limit switch from left hand vertical column. Select right hand switch from right hand horizontal column. The correct cat. no. is found at the intersecting box. Most levers listed on page 5-0 can be used. When dual limit switch combinations are desired, consult your local Rockwell Automation sales office or Allen-Bradley istributor(see page -). Approximate imensions [mm (in.)]. (.5).5 (0.7).5 (0.7) 9 (0.75) 5. (.7) 5.9 (.).7 (0.).7 7. ().9 (.5) ual Switch with 0T -W Levers Shipping Wt. 0.9 kg ( lbs) Conduit.9 (.5) 7. () 9 (0.75) 0.75 ia NPT 0.57 (0.) 5.97 (.) Levers See page 5-0 for a complete listing of operating levers. Modifications and Accessories See page 5-7. Visit our website: 5-7
31 0T Air-Operated Spring Return Product Selection Contact Operation Will operate when 5 psi (7 kpa) ±5% of air pressure is applied, and will reset with a pressure drop of 5 psi ( 0 kpa). Maximum allowable pressure is 00 psi (0 kpa). Single Unit ouble Unit 0T -P 0T -P When the switch is in the reset state a small rod protrudes from the top of the die casting. The rod is flush with the surface when the switch trips on higher pressure. The switch can be manually operated by pressing down on the rod. Contact operation similar to -circuit devices. Contact operation similar to -circuit horizontal construction devices. Approximate imensions [mm (in.)] 9.5 (0.).5.7 (0.).9 (.0).5 7. (.) 59. (.) Air-Operated Switch Shipping Wt. 0. kg ( oz) Conduit -5. (0.) ia. Holes for Front Mtg..7 (0.5). (0.) 0.5 in. ia. NPT 9. (.). (.5).9 (.7) Modifications and Accessories See page Visit our website:
32 0T Modifications and Accessories Front View Cavity Mounting 0T -AO with 0T -WA Lever Manifold Mounting Rear View 0T -AMU with 0T -WA Lever Cavity Mounting Except for the types identified by Cat. Nos. 0T--B, 0T--, 0T--WS, 0T--WS, and 0T--CW, Bulletin 0T switches can be supplied in a special construction for cavity mounting in a machine base or panel. With this construction, the actuator and contact block are mounted on the back of a gasket steel plate. To order a switch for cavity mounting, add the letter O to the cat. no. of the corresponding surface mounted switch. Example: 0T--A becomes cat. no. 0T--AO (shown). Manifold Mounting All two-circuit Bulletin 0T switches canbesuppliedwithaspecialbase which permits mounting the switch manifold style on a machine base, panel or raceway. This base is equipped with a wiring hole and synthetic rubber gasket on the back (see illustration). To order a switch with a manifold mounting base, add the letter U to the cat. no. Example: 0T--AM becomes cat. no. 0T--AMU (shown). Transparent Cover Switches can be furnished with a gasket, transparent plastic cover. This modification enables the electrician to inspect terminal wiring without removing the switch cover. Not available on cat whisker, time delay or cavity style mounted limit switches. To order a switch with a transparent cover, add the letter Z to the cat. no. of the switch. For example: 0T-- becomes 0T--Z. Extended Temperature Operation Bulletin 0T nonplug-in limit switches are designed to operate in a temperature range of C (0 +0 F). Special limit switches modified for extended temperature operation C ( F) are available. Note: Temperature ranges below 0 C (+ F) are based on the absence of freezing moisture or water. To order a Bulletin 0T modified for extended temperature operation, insert the letter E after the operating head designation. Example: 0T--A becomes 0T--AE. (Cat. Nos. 0T--WS, WS, CW, P, P and the time delay limit switches are not available for extended temperature operation. Cat. Nos. 0T--A and A are available for extended temperature operation except with a reduction in damping.) Special Conduit Positions ual operating head switches can be obtained with up to three conduit openings. The location of conduit openings A, B, and C are illustrated in the dimension drawing on page 5--. The conduit opening in Position A is / in. NPT, the conduit openings in Position B and C are / inch NPT. To order a switch with special conduit positioning, add the suffix S, S or S to the cat. no. per the following: S=Position A+B S=Position A+C S=Position B+C Neon Indicating Lights (-Circuit Models Only) Two circuit Bulletin 0T surface mounted limit switches can be supplied with two neon indicating lights AC 0/0V, 50 0 Hz and 0V, 50 0 Hz. To order, add the letter N for 0V or N5 for 0V before the lever designation. Example: 0T--A with indicating lights would be 0T--AN. Not available on -circuit devices. In addition, indicating light kits as shown in the table below are available for field installation on two circuit devices. Limit Switch Construction Surface Mounted Light Kit 0V AC 50 0 Hz 0/0V AC 50 0 Hz 0T- N 0T- N Neutral Position 0T- N 0T- N0 Conduit Seal A synthetic rubber conduit seal is available to protect the conduit opening against entry of oil and moisture. The seal can be added easily before switch installation and should be installed so that the 5/ inch diameter projection (the other projection is / inch diameter) faces against the shoulder at the bottom of the pipe tap. The seal can accommodate up to four wires of # gauge or smaller. Each wire hole in the seal has a thin inner wall which is pierced when a wire is passed through. Thus, any unused opening remains sealed. The seat is designed for single contact block, surface mounted base limit switches having / inch conduit openings. Conduit seal... 0T- N Special Conduit Lock Nut This option, a Tru-Seal nut with threaded PTFE insert, is a valuable accessory for any Bulletin 0T which is connected by means of conduit. Tru-Seal lock nut for / inch conduit... 0T- X Visit our website: 5-7
802T Plug-in Style Oiltight Switches
Limit es 80T Plug-in tyle Oiltight es pecifications Enclosure Rating Pollution egree Certifications Ambient Temperature [C (F)] NEMA,, 6P and IP67 UL Listed, CA Certified CE Marked for applicable directives
More informationEasy Mounting and Wiring
Limit es 80T Introduction Plug-in Style 80T-AP with escription NonPlug-in Style 80T-Awith Bulletin 80T limit switches are ideal for applications in which heavy duty pilot ratings, small size, a high degree
More informationContents. Limit Switches. Quick Selection Guide... page 6 2. Technical Definitions and Terminology... page 6 6
Contents.............. page 6 2 Technical Definitions and Terminology......................... page 6 6 Bulletin 801 General Purpose....... page 6 7 Bulletin 802A International Style Position Switches..................
More informationProximity Sensors and Limit Switches The Heart of the Line for Robust and Reliable Control
Proximity Sensors and Limit Switches The Heart of the Line for Robust and Reliable Control Our Most Popular Proximity Sensors 872C WorldProx - General Purpose For less aggressive yet still demanding applications,
More informationProximity Sensors and Limit Switches The Heart of the Line for Robust and Reliable Control
Proximity Sensors and Limit Switches The Heart of the Line for Robust and Reliable Control Our Most Popular Proximity Sensors 872C WorldProx - General Purpose For less aggressive yet still demanding applications,
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More information3SE03 North American Limit Switches
General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.
More informationAvailable as assembled switches or components. E50ANR1 with E50KL200 Lever. Conduit, cable and connector wiring options
Modular Plug-In Limit Switches E50 Series Available as assembled switches or components E50KL200 Easy to Install High Reliability Low Maintenance Modular to Reduced Inventory E50ANR1 with E50KL200 Lever.
More informationApplications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings
Selection Guide Severe Duty Mill and Foundry Switches pplications Mill Mill Mill Mill Design 9007T Convertible sequence L0 Fixed sequence L14 Single Cable Pulls Fixed sequence L525 elt Conveyor Fixed sequence
More information3SE03 North American Limit Switches
General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.
More informationPressure Controls Product Overview
Bulletin Product Overview NEMA Bulletin Style A (Internal Bellows) Description Style C (External Bellows) Air Compressors Compressed Air Monitor Systems Liquid Level Control Typical Applications Vacuum
More informationSpecifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Auxiliary Contacts. Actuation Speed, Max.
AUDIN - 8, avenue de la malle - 70 Saint Brice Courcelles - Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr 80T Direct Opening Action Description The 80T Direct Opening
More information2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.11 Product Description Features Special Purpose (Type F), Rotating Shaft (Type J),
More information1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information
1980 Rotating Cam Limit Switches Ordering Guide & Technical Information Features Precision Cam adjustment at any angular position of the Camshaft Speeds from 0 to 500 RPM in either direction No special
More information2006 Series Geared Rotary Limit Switches
SUPERIOR DESIGN AND OPERATING FEATURES Quality parts make each Geared Rotary Limit Switch highly dependable. The limit switch s ½" input shaft is connected to a worm gear. Adjustable self-lubricating nylon
More informationAn Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches
An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety
More informationProximity Sensors and Limit Switches
Proximity Sensors and Limit Switches Time-tested, Robust and Reliable Control 6 / 2011 INDUCTIVE SENSOR PRODUCT SPOTLIGHT Allen-Bradley proximity sensors set the standard for ruggedness, reliability and
More informationMultiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous
Proximity Limit Switch The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous metals. All components are sealed and protected within the rugged brass housing eliminating
More informationLimit Switches E47 Precision Switches
1 PG.0C.0.T.E July 0 E47 Precision The Cost-Effective Solution for Highly Accurate Switching Applications Contents Overview...................... 1 Model Selection, Basic Switches................ 2 Model
More informationED SERIES SAFETY LIMIT SWITCH
Description The ED series safety limit switches conform to EN 547 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make
More informationSafety Limit Switch
Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit
More informationLimit Switches Heavy-Duty Plug-In Switches
1 Contents Overview...................... 1 Model Selection, Assembled Switches..................... 2 Model Selection, Operating Heads.............. 5 Model Selection, Switch Bodies................. 6
More informationIEC Limit Switches Selection Guide
IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,
More informationSelector Push Button Cat. No. 800T-K2AAXX. a b c d e f g Right Left Right Left. d, e, f, g. Contact Blocks. No contacts on operator
NEMA Push Specifications 800T/H 30.5 mm Push s Selector Push Devices (Bul. 800T only) Selector Push Cat. No. 800T-K2AAXX 800T KD 2 G J D E a b c d e f g Right Left Right Left Blank C K KA KB KC KD KE a
More information2000 Series Geared Rotary Limit Switches
SUPERIOR DESIGN AND OPERATING FEATURES Quality parts make each Geared Rotary Limit Switch highly dependable. The limit switch s ½ input shaft drives a bronze gear which rotates the cam block. The cam block
More informationBulletin 871P Can Sensors
Bulletin 871P Can Sensors Description Bulletin 871P inductive proximity can sensors are self-contained solid state devices, designed specifically for sensing size 202 to 704 metal cans without physical
More informationD4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications
Safety Limit Switch Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications H Snap-action contact for accurate switching with safe operation via direct drive positive
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position Metal Push-Pull
More informationED SERIES SAFETY LIMIT SWITCH Description
Description The ED series safety limit switches conform to EN 50047 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make
More informationMAX-E1 FAMILY NEMA PREMIUM EFFICIENCY
MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp
More informationIEC Limit Switches Selection Guide
IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationValve Products. Valve Products Section D. Valve Products. Catalog PDN1000-3US Parker Pneumatic
Section irect Acting Valves - irect Acting Pictorial Index - www.parker.com/pneu/valve Inline continued N - Inline Poppet Inline or stacking /8 inch ports Pressures 0 to 5 PSIG Temperatures F to 5 F Flow
More informationLimit Switches. Reference Information. Proper Application of Limit Switches General Information. Definition of Limit Switch Terms.
Reference Proper Application of General switches are used to convert a mechanical motion into an electrical control signal. The mechanical motion is usually in the form of a cam, a machine component or
More informationLimit Switches Schneider Electric All Rights Reserved. Limit Switches 10/02
Steven Engineering-0 Ryan Way-South San Francisco, CA 9080-70-Main Office:(0)88-900-Outside ocal Area:(800)8-900-www.stevenengineering.com 00/00 Severe Duty Mill and Foundry and Specifications 00/00 Severe
More informationEnvironment-Sealed Basic Switches
HoneywellSensing and Control 1-800-537-6945 USA 1-815-235-6847International 1-416-293-8111Canada 13 Environment-Sealed Basic Switches GENERAL INFORMATION SE and XE switches are the smallest environment-sealed
More informationSeries Gemco. Rotating Cam Limit Switches. Micro-Adjust Cams. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH
Series 1980 Gemco Rotating Cam Limit Switches Micro-Adjust Cams Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com FEATURING PRECISION
More informationMICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series
MICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series DESCRIPTION When the application requires an industrial grade limit switch where wet, dust, or corrosive environments may be present,
More informationHS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key
HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available
More information127 (5) Approx (1.85) Overmold. Male Coupling Nut. Straight Micro Female 63.5 (2.5) 127 (5) Approx. Overmold Coupling Nut Straight Mini Female
KwikLink Lite Flat Drop General Quick Selection Introduction KwikLink Lite Drop Cordset with 4-wire unshielded cable. Device connection options include 5 pin mini and micro as well as flying leads. Physical
More informationRobust General-Purpose Limit Switch WL
Robust General-Purpose Limit Switch WL Wide Selection of Two-Circuit Double-Break Limit Switches Rugged diecast housing High mechanical strength Oiltight, waterproof, dustproof construction Overtravel
More informationLimit Switches. Heavy-Duty Plug-In Switches
1 Contents Modular Provide Extremely Easy Installation, High Reliability, and Low Maintenance and Inventory Costs Overview..................... 1 Model Selection, Assembled Switches.....................
More informationInternational, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in.
HMS/HLS/HNS Series Heavy Duty Limit Switches Features Heavy duty zinc die cast body Conform to EN 6097-5-1, IEC 6097-5-1, UL508, NEMA250, CSA22.2 Standards Wide range of actuator available High repeatability
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS HEAVY DUTY LIMIT SWITCHES Types T and FT Robust, heavy duty switch 15 operating sequences available Most sequences are convertible in the field. Type T suitable
More informationHS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.
HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded
More informationCondensed Catalog 2006 North America
MAKING MODERN LIVING POSSIBLE One call to Danfoss and you re in control Danfoss Industrial Automation gives you fast access to one of the widest ranges of quality industrial controls available. More and
More informationPneumatic Isolation Module
Pneumatic Isolation Module (Cat. 2030-Pxxxxx) ATTENTION: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: Prior to beginning the installation and wiring process,
More informationP70, P72, and P170 Controls for Low Pressure Applications
Master Catalog 125 Pressure Controls Section P Product/Technical Bulletin Issue Date 0900 P70, P72, and P170 Controls for Low Pressure Applications The P70, P72, and P170 controls for low pressure applications
More information2.6. Limit Switches. Contents Description. E50 Heavy-Duty Plug-In Switches. E50 Heavy-Duty Plug-In Switches. Product Description
.6 Limit Switches Product Features E50 Modular Plug-In Limit Switch Components from Eaton s electrical sector are the industry standard with versatility of design and high reliability for low maintenance,
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationSection 11. Specialty Control Devices. Control Catalog 11-1
Industrial Strongbox Solenoids (CR9500) Introduction...11-2 AC Solenoid Forms...11-3 Mounting Options and Accessories for AC Forms...11-3 DC Solenoid Forms...11-4 Outlines and Dimensions...11-4 Heavy Duty
More informationLimit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.
Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with
More informationPressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction
K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller
More information1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information
1980 Rotating Cam imit Switches Ordering Guide & Technical Information Features Precision Cam adjustment at any angular position of the Camshaft Speeds from 0 to 500 RPM in either direction No special
More informationCompact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration
C R US Conforms to EN418, EN292, EN0947-5-1, EN50041, BS504, ISO1850 UL and C-UL listed ER4020 Compact Rope-Activated Emergency Stop Switch Compact size allows this switch to be used on smaller machines
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More information% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.
Direct Acting Direct Mount Pilot Valves Brass or Stainless Steel Bodies /" NPT / 83 Direct Mount Features NAMUR direct mount version of the rugged, dependable 83 Series valves Direct acting, high flow
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationFF Pressure Switch. Diaphragm and piston switches
FF Pressure Switch FF Pressure Switch Diaphragm and piston switches Product informations The new FF pressure switch design is based on 40 years of know-how and is an example for consequent quality oriented
More information600V, Non-Fusible, (3-Pole, 3 Phase)
0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More information3340 Series Single Stage End Suction Pumps
3340 Series Single Stage End Suction Pumps Bulletin 3340/Rev. A Model 3344 Aurora 3340 Pump Setting New Standards of Efficiency Liquid handling requirements are much more involved than they were five years
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More information2.6. Limit Switches. Contents Description. E50 Heavy-Duty Plug-In Switches. E50 Heavy-Duty Plug-In Switches
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.6 Product Features E50 Modular Plug-In Limit Switch Components from Eaton s electrical
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:
More informationHS1E Series Full Size Solenoid Locking Switches
HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationInstallation Instructions
Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,
More information9012G Pressure and 9016G Vacuum Switches
Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:
More informationCylinder Position Sensors
TECHNOLOGY IN ACTION Stroke-to-GO LEVERLESS LIMIT SWITCH GO Switch Stroke-to-GO cylinder position sensors use three permanent magnets and push-pull plunger assembly to control a set of dry contacts. A
More informationSafety Limit Switch
Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_4_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit
More informationGLS Series Global limit switch
GLS Series Global limit switch Features EN 50041 and EN 50047 esigned to IEC electrical standard for world-wide use Forced disconnect Normally Closed contacts conform to IEC 60947-5-1-3 Rugged housing
More informationSWITCH PRESS 4-150PSI 316SS St Item Text PRESSURE SWITCH, PSI, 270 PSI MAX LINE PRESSURE, NEMA 4X ENCLOSURE, STYLE C EXTERNAL BELLOWS,
1000743 SWITCH PRESS 4-150PSI 316SS St Item Text PRESSURE SWITCH, 4-150 PSI, 270 PSI MAX LINE PRESSURE, NEMA 4X ENCLOSURE, STYLE C EXTERNAL BELLOWS, 316SS BELLOWS, WITH 1/4" NPT FEMALE CONNECTION, SPDT
More informationConstructions Suitable for -40 C to -50 C Ambient
Constructions Suitable for -40 C to -50 C Ambient 2, 3 and 4 Way Constructions Available Brass and Stainless Steel Bodies Air and Inert Gas Service AIR/INERT GAS QUALITY STATEMENT FOR LOW AMBIENT VALVES
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationThe following valve actuators are compatible with all Clippard MAV, MAVO, MJV, MJVO, ES-1, & FV series valves.
VALVE ACTUATORS The following valve actuators are compatible with all Clippard MAV, MAVO, MJV, MJVO, ES-1, & FV series valves. One of the most versatile items in the Clippard line. Permits wide circuit
More information13-3. Bulletin 836T, 837, 803 Pressure & Temperature Controls Product Overview/Renewal Parts. NEMA Pressure and Temperature Controls
Bulletin T,, Pressure & Temperature Controls Product Overview/Renewal Parts NEMA Pressure and Temperature Controls Features Bulletin T Operating Range Independently adjustable trip and reset settings Heavy-duty
More informationPneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves
Quic-Pics Catalogue Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Contents: Product Line Overviews 2 Manually Operated Valves 5 Pushbuttons 6 Toggle Switch 8 Knob
More informationRosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries
Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering
More informationD4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information
Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding
More informationDouble insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators
Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)
More informationHeavy Duty, Industrial General Specifications XCKJ. Electrical Ratings Non-plug-in: A300 (AC), Q300 (DC)
Heavy Duty, Industrial General Specifications Rated Power Conforms to IEC 947-5-1, duty categories AC15 and DC13. emperature range -13 F to 158 F (-25 C to 7 ); optional -4 F (-4 C); +248 F (12 C). he
More informationConstructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies
Constructions Suitable for - C to -5 C Ambient, 3 and Way Constructions Available Brass, Aluminum and Stainless Steel Bodies Air and Inert Gas Service INDEX General Service Valves -Way/ Position 8 Aluminum
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationDouble Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company
PNEUMATIC ACTUATOR SERIES 92/93 Rack & Pinion Double Acting & Spring Return The High Performance Company SERIES 92/93 Styling, strength, compactness, and simplicity of design have been combined to produce
More informationSelection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic
Limit switches Selection diagram Actuators A A S B B 3 H G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping
More informationCOMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications
Class I, Division per NEC 50.0(B)() Applications Larger body size facilitates pulling of large and heavy conductors. Specially designed raised cast covers provide additional wiring area. Mogul Unilets
More informationDoor Interlock Switches
HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws
More informationModel Number Structure
Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationVL Series. General Purpose Compact Limit Switches. Sensing and Control
FEATURES Gold plated silver contacts Compact design for small mounting space. Special design for easy wiring with ample wiring space Two-circuit double-break Diecast base and plastic cover Standard mounting
More informationonlinecomponents.com VL Series General Purpose Compact Limit Switches Sensing and Control
FEATURES Gold plated silver contacts Compact design for small mounting space. Special design for easy wiring with ample wiring space Two-circuit double-break Diecast base and plastic cover Standard mounting
More informationControl Circuit Transformers
Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit
More informationControl & Power, Inc
Way/ 2 and 3 Position Four ported valves are generally used to operate double-acting cylinders or actuators. They have four or five pipe connections, commonly called ports: One pressure inlet. Two cylinder
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight
More informationHinged Safety Door Switch
Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),
More informationGeneral Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features
TM WEG W21 Severe Duty motors meet the most demanding severe duty application requirements. These TEFC motors are all cast iron construction, with enclosures rated IP55 to handle wet and dirty environments.
More information2-Way/2 Position Valves
4 2-Way/2 Position Valves Two-way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply Normally Closed (NC) Fluid is shut off when
More information3 Way/2 Position Valves
Way/ Position Valves Three way valves have three pipe connections and two orifices. When one orifice is open, the other is closed, and vice versa. They are commonly used to alternately apply pressure to
More information