1 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Mill and Foundry and Specifications 00/00 Severe Duty Mill and Foundry - Descripton and Specifications Severe duty limit switch series designed for difficult mechanical and electrical environments such as steel mills and foundries. Captive cover screws Heavy duty snap action mechanism prevents teasing or false contact opening Positive trip action which doesn't allow the lever to slip around the 0." (.7) shaft even if not properly tightened High current capability. 0 amp maximum continuous Isolated (no polarity) double and triple circuits with double break (throw) action Wide 0." (.) contact gap ensures very high shock and vibration resistance Easy to access contacts allow for easy inspection and replacement Stamped contact configuration number for easy identification even if the switch is painted Many contact arrangements to solve difficult applications Model 00 is an extra heavy duty version for very aggressive environments The booted shaft design prevents penetration of foreign materials (sand, dust, grit, etc.) between the shaft and the bushing Heavy duty stainless steel springs and hardened spring operators permit longer life under extreme lever flyback and high impact Same parameters as 00 models except the distance between the back of the switch and the lever (0." (8.) greater). Two and three circuits in CW, CCW, neutral position, spring return and maintained, snap action or slow-make slow-break, two steps () are available circuit models can be CW or CCW field converted Wide range of options: high shock and vibration, with gold contact, low or very high temperature 0." (.7) PT conduit entrance standard on pole models ( wires max.) 0.7" (9) PT conduit entrance standard on pole models (7 wires max.) U isted devices: 00W, 00W, W, W, 0 through 9, 0 through 9, and. All of these can be followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and may be followed by or. 00W and 00W, followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and followed by or. 00/00 Severe Duty Mill and Foundry - and Specifications Schneider Electric All Rights Reserved 0/0
2 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Mill and Foundry and Specifications General Specifications Temperature range 0 F to 00 F (-7 to 9 ) optional -0 F (-8 C); +0 F (7 C) The minimum temperatures listed are based on the absence of freezing moisture or water. Enclosure rating EMA Type, and Vibration resistance 0G max. (0-Hz) Repeatability 0.0 Cable entry 0. " (.7) PT standard Double Circuit, 0.7" (9) PT Triple Circuit Contact characteristics Rated thermal current 0 A Rated insulation voltage 00 VAC and DC Wire (max.) x # AWG or x # AWG per screw terminal Switching Ratings: A00 (AC), P00 (DC) (M = Make, B = Break) Front Covers Contact Rating Designation Maximum current (Amp) Maximum 0 V V 0 V 0 V 80 V 00 V Volt Amps M B M B M B M B M B M B M B A00 (AC) P00 (DC) Interpretation of the Catalog umbers The diagram below is intended to help understand how the catalog number is laid out. It is to be used with existing numbers only from the following pages. ew catalog numbers should not be generated, built up or developed from the table below. If the contact sequence required is not listed, contact your local field office. The only modifications to the existing catalog numbers are: Mounting Plates. Select style,, or Style PF Front Covers. Select metal, transparent plastic, or transparent plastic with neon light. Special Features. Select special features from page 9 and add to type number as instructed. Style Housing Function Mounting Plate Front Cover 0 0 W S P F Contact Arrangement Standard (Mill) 00 Style M Standard metal U isted devices: 00W, 00W, W, W, 0 through 9, 0 through 9, and. All of these can be followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and may be followed by or. 00W and 00W, followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and followed by or. Extra heavy duty (Foundry) Belt Conveyor Two circuit single Style GF WS operation Two circuit dual operation WD Style Triple Circuit WT eutral W Mounting plates 00 and 00 models (Dimensions page 98) 00 Style PF Transparent plastic Transparent plastic with neon light Style Style Style Style 0/ Schneider Electric All Rights Reserved 89
3 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Mill and Foundry Selection Information 00?00 Severe Duty Mill and Foundry - Selection Information Type Selection Contact Diagram Operating Torque Catalog umber Snap-action CW Spring return 90 oz-in (. m) 00WSM 90 oz-in (. m) 00WSM 90 oz-in (. m) 00WSM Snap-action CCW Spring return 90 oz-in (. m) 00WSM Maintained contact c CW and CCW Snap action oz-in (0. m) 00WSM oz-in (0. m) 00WSM 90 oz-in (. m) 00WDRM Snap action CW Spring return 90 oz-in (. m) 00WDRM 90 oz-in (. m) 00WDRM Snap action CCW Spring action 90 oz-in (. m) 00WDRM Maintained contact c CW and CCW Snap action oz-in (0. m) 00WDRM oz-in (0. m) 00WDRM 90 oz-in (. m) 00WDM7 Snap action CCW Spring return 90 oz-in (. m) 00WDM7 90 oz-in (. m) 00WDM8 Snap action CW Spring return 90 oz-in (. m) 00WDM8 Snap action CW.C./.O. spring return Snap action CCW.O./.C. spring return 90 oz-in (. m) 00WTRM0 90 oz-in (. m) 00WTRM0 90 oz-in (. m) 00WTRM 90 oz-in (. m) 00WTRM Maintained contact c CW and CCW Snap action, poles oz-in (0. m) 00WTRM oz-in (0. m) 00WTRM Snap action CCW Spring return,.o./.c. 90 oz-in (0. m) 00WTM 90 oz-in (0. m) 00WTM Snap action CW Spring return,.o./.c. 90 oz-in (0. m) 00WTM 90 oz-in (0. m) 00WTM Maintained contact c CW and CCW Snap action, poles oz-in (0. m) 00WTM oz-in (0. m) 00WTM Schneider Electric All Rights Reserved 0/0
4 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Mill and Foundry Selection Information Type Selection (Continued) One.O. contact per direction 9 oz-in (0.7 m) 00WM 9 oz-in (0.7 m) 00WM One.O. contact for both directions 0 9 oz-in (0.7 m) 00WM7 9 oz-in (0.7 m) 00WM7.C.-CW,.C.-CCW 9 oz-in (0.7 m) 00WCM8 9 oz-in (0.7 m) 00 WCM 8.O.-CW,.O.-CCW 9 oz-in (0.7 m) 00WTRM0 9 oz-in (0.7 m) 00WTRM0.O.-CW,.O.-CCW 9 oz-in (0.7 m) 00WTM 9 oz-in (0.7 m) 00WTM Slow make-before-break, CW Spring return 70 oz-in (. m) 00WS0M 70 oz-in (. m) 00WS0M Slow make-before-break, CCW Spring return 70 oz-in (. m) 00WS0M 70 oz-in (. m) 00WS0M.O.-CW,.O.-CCW Spring return, snap action 70 oz-in (. m) 00WSM 70 oz-in (. m) 00WSM.O.-CW,.O.-CCW Maintained in CCW only.o.-cw,.o.-ccw Maintained in CW only 70 oz-in (. m) 00WSRM8 70 oz-in (. m) 00WSRM8 70 oz-in (. m) 00WSM9 70 oz-in (. m) 00WSM9.C.-CW,.C.-CCW Spring return, snap action 70 oz-in (. m) 00WCSM 70 oz-in (. m) 00WCSM.O.-CW,.O./.C.-CCW 9 oz-in (0.7 m) 00WTRCM8 9 oz-in (0.7 m) 00WTRCM8.O./.C.-CW,.O.-CCW 9 oz-in (0.7 m) 00WTCM9 9 oz-in (0.7 m) 00WTCM9 0/ Schneider Electric All Rights Reserved 9
5 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Mill and Foundry Selection Information Type Selection (Continued).O./.C.-CW,.C.-CCW 9 oz-in (0.7 m) 00WTRCM0 9 oz-in (0.7 m) 00WTRCM0.C.-CW,.O./.C.-CCW 0 9 oz-in (0.7 m) 00WTCM 9 oz-in (0.7 m) 00WTCM.O./.C.-CW,.C.-CCW Spring return, snap action 9 oz-in (0.7 m) 00WTRCSM8 9 oz-in (0.7 m) 00WTRCSM8 Step Sequence CW Spring return, snap action,.o. 0 oz-in (.0 m) WDRM Step Sequence CCW Spring return, snap action,.o. 0 oz-in (.0 m) WDM7 Step Sequence CW Spring return, snap action,.c. 0 oz-in (.0 m) WDM8 Step Sequence CCW Spring return, snap action,.c 0 oz-in (.0 m) WDRM9 Step Sequence CW Spring return, snap action,.o./.c c ever must not be allowed to snap freely from any overtravel position. ever arms page page 9 Belt Conveyor imit Switch 0 oz-in (.0 m) 00WS0SM0 Typical application for step sequence limit switches above. Used with rolling pin levers A0 and A80 (page 9). WDR and WD two step sequence switches are typically mounted with one on each side of the conveyor belt. The first step is used to signal that the belt is out of position (alarm). The second step usually stops the conveyor. U isted devices: 00W, 00W, W, W, 0 through 9, 0 through 9, and. All of these can be followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and may be followed by or. 00W and 00W, followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and followed by or. Acceptable Wire Sizes AWG Recoended Terminal Clamp Torque lb-in (. m) File 9 CC KCR File R90 Class -0 Marking Schneider Electric All Rights Reserved 0/0
6 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Selection Information - ever Arm 00/00 Severe Duty Selection Information - ever Arm.. Dual Dimensions Style A inches.0. Over 00 styles of levers to accoodate most of the industrial applications Made of aluminum bar stock hardened to 8,000 psi tensile strength to combine strength with light weight Positive trip action implemented by 8 broached serrations on lever and shaft ensures no loss of mechanical contact (slippage) even if the lever is loosely mounted on the shaft. ever position can be adjusted in 7. increments. Style A - Steel roller (0." (.) wide, 0.7"(9) diameter) ength () ever I umber. (.7) AC.0 (8.) AA.7 (.) AD.00 (0.8) AH. (7.) AJ.0 (.) AO.7 (9.8) AK.00 (7.) AB.0 (88.9) A.00 (0.) AM.0 (.) A.00 (7.0) AP.0 (9.7) AQ.00 (.) AR " (.) diameter roller." () diameter roller."(8.) diameter roller ylon roller Ball bearing roller (0.7" (9) diameter) R Stainless steel roller pin nylon roller S.. Style B.0. Ex: AB; ABR Style B - Steel roller (0." wide, 0.7" diameter) ength () ever I umber.0 (8.) BA.00 (0.8) BH.0 (.) BO.00 (7.) BB.00 (0.) BM.0 (.) B.0 (9.7) BQ.00 (.) BR U isted devices: 00W, 00W, W, W, 0 through 9, 0 through 9, and. All of these can be followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and may be followed by or. 00W and 00W, followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and followed by or. ylon roller." (8. ) diameter Ex: BA; BA OTE: Other options available. Contact your Square D representative for more details. 0/ Schneider Electric All Rights Reserved 9
7 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Selection Information - ever Arm 00/00 Severe Duty Selection Information - ever Arm Style C - Steel roller on side (0." (.) wide, 0.7" (9) diameter) ength Inches ever umber..7 CC.0 8. CA.7. CD CH.0. CO CB C CM.00. CR Style C (Style C) " (.)diameter roller." () diameter roller." (8.) diameter roller ylon roller Style E - One Way Steel Roller (0." (.7) wide, 0.7" (9) diameter) ength I ever umber.0 8. EA.7. ED EB..8 Style E.0.7 ylon roller Style F - Offset, Steel Roller (0." (.8) wide, 0.7" (9) diameter) ength () Offset (x) I I ever umber FB FA FC FE FG FI FJ..8 Style F.0.7 " (.) diameter roller (FE, FG, FI, FJ only) ylon roller OTE: Other options available. Contact your Square D representative for more details. U isted devices: 00W, 00W, W, W, 0 through 9, 0 through 9, and. All of these can be followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and may be followed by or. Dual Dimensions inches 00W and 00W, followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and followed by or Schneider Electric All Rights Reserved 0/0
8 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Selectin Information - ever Arm Style R (Rod) Hub only Rod only (Stainless Steel) 00/00 Severe Duty Selection Information - ever Arm ever umber R R Style R Adjustable from 7 to 80 in increments of Style V (Yoke) - for maintained position switches ever umber Style V VA " (.) diameter roller ylon roller Ball bearing roller (0.7" (9) diameter) R Style V Style A - to pass over switch cover ength () / Inches () Catalog umber.0 (0) AA.00 (0) AH.0 () A0 - Substitute with:." (8) diameter roller ylon roller Style A.7.9 Style C - to pass over switch cover ength () / Inches () Catalog umber.0 (0) CA.00 (0) CH.0 () CO - Substitute with:." () diameter roller." (8.) diameter roller ylon roller.7 9 Style C..7 Rolling Pin - for use with step switches for conveyor or belt applications ength () / Inches () ever umber. (7.) A 0. (7.) (For high temperature applications) A 0- (Teflon) (0.8) A Adjustable from " () to " (0) roller (0."(.) wide, 0.7" (9) diameter) ever umber " to " ( to 0 ) A 80 OTE: Other options available. Contact your Square D representative for more details. Rolling Pin Adjustable.9.8 Dual Dimensions inches U isted devices: 00W, 00W, W, W, 0 through 9, 0 through 9, and. All of these can be followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and may be followed by or. 00W and 00W, followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and followed by or. 0/ Schneider Electric All Rights Reserved 9
9 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty and Accessories Mini Change Connector 00/00 Severe Duty - and Accessories Housing k Prefix Adder or Modifier 0.7" (9) conduit opening Available on circuit switches. Standard on circuit switches. Ex. 00WSM changes to G00WSM G High temperature 0 F to +0 F c Metal front cover only Ex. 00WSM changes to H00WSM H ow temperature -0 F to 00 F c Ex. 00WSM changes to T00WSM T High shock Available only on operating sequences,,,, 7-,,. Gold contacts Ex. 00WSM changes to WSM Ex. 00WSM changes to WSM Ex. 00WSM changes to WSM Ex. 00WSM changes to WSM / / Wiring Straight male receptacle pin q Factory prewired 90 Angle male receptacle pin q Factory prewired - facing right Ministyle male receptacle j 8A max. pin (double circuit) 7A max. 7 pin (triple circuit) Potted and prewired wires feet (.8 ) long wires feet (. ) long wires 8 feet (. ) long Ex. 00WSM changes to P00WSM Ex. 00WSM changes to AP00WSM Ex. 00WSM changes to B00WSM Ex. 00WSM changes to 00WSMP Ex. 00WSM changes to 00WSMP Ex. 00WSM changes to 00WSMP8 P AP B B P P P8 Straight Male Connector Front covers Standard metal Transparent plastic cover with metal frame Transparent plastic cover with metal frame and eon indicator light (not connected) Ex. 00WSM changes to 00WSPF Designator M PF GF 90 Angle Male Connector U isted devices: 00W, 00W, W, W, 0 through 9, 0 through 9, and. All of these can be followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and may be followed by or. Accessories Catalog umber Sealed female plug and cable for P and AP connector ' 0000 pins, # AWG STO cable, 0 F (0 C) ' ' Sealed female plug and cable for ministyle connector (B) ' of cable BH0 pins, # AWG STO cable, F (0 C) ' of cable BH0 ' of cable BH0 k Other options available - contact your Square D/TE representative for details. q Receptacle is a pin male AP/P-SWTS, Cannon part # MS0E0-P-F79 or equal. j Ministyle male connector are: -pin: Brad Harrison #0 (or equal) 7-pin: Brad Harrison #80 (or equal) c The minimum temperatures listed are based on the absence of freezing moisture or water. 00W and 00W, followed by D, DR, CS, S, S, T or TR, followed by, followed by M, and followed by or Schneider Electric All Rights Reserved 0/0
10 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty - and Accessories 00/00 Severe Duty and Accessories 7 8 CAUTIO: Do not use solvents to clean CAUTIO: Do not use solvents to clean interior of electrical compartment. interior of electrical compartment. Solvents may damage the high dielectricsolvents may damage the high dielectric thermoplastic insulation. thermoplastic insulation. Parts which may be ordered individually are shown below. These parts are standard for A models (includes P and AP versions), contact arrangements through 7. For replacements only not for modifications of existing switches. Reference umber Quantity Required Top cover assembly Style M (includes gasket and screws) 0 Style PF (includes gasket and screws) 0 Style GF (includes gasket, bulb, frame and screws) 09 t Contact repair kit: Silver contacts 97 Gold contacts 97 atch assembly 700 Standard shaft kit, 00 and 00 models 98 eutral shaft kit, 00 and 00 models 97 Standard shaft kit, 00 models 0 eutral shaft kit, 00 models 07 High temp standard shaft kit H 98 7 Return spring 8 End bearing plate Contact ARR -, -, -, 9-0, 0 Contact ARR -, -, -8, 0-, 7, 7, 7, 7 0 Mounting plate Style (includes gasket and screws) 9 9 Style (includes gasket and screws) 97 Style (includes gasket and screws) 98 Style (includes gasket and screws) 99 Operating spring 80 Operating spring (neutral) 8 t Contact repair kit: Reference consists of essential contacts, long fiber and short fiber retainers, and springs to replace moving contact assembly. 9 Catalog umber Electrical Repair Kits () Consists of all terminals, contacts and accessories to completely replace electrical compartment. For replacements only not for modifications of existing switches. Contact Arrangement For Switch Model Catalog umber Contact Arrangement For Switch Model Catalog umber 00WS WT WS WSO WS WSO WDR WS WDR WSR WDR WS WD WCS WD WTRC WTR WTC WTR WTC WTR WTC WT WTRCS WT 800 WDR WT WD W WD W WDR WC WS0S WTR 800 0/ Schneider Electric All Rights Reserved 97
11 Steven Engineering-0 Ryan Way-South San Francisco, CA Main Office:(0) Outside ocal Area:(800) /00 Severe Duty Approximate Dimensions 00/00 Severe Duty - Approximate Dimensions Switches Switch shown with AA lever Model Type with style mounting plate Model 00 CA ever AA ever " - 0 tap." deep holes both sides.0. /" pipe tap - circuit switches /" pipe tap - circuit switches " - 0 tap." deep holes both sides /" pipe tap - circuit switches /" pipe tap - circuit switches Mounting Plates Style Style Style Style dia dia. mounting hole.0. slot mtg hole mounting holes dia hole Receptacles P AP Ground clamp screw. 7. Ft. / STO cable Yellow Dual Dimensions inches Schneider Electric All Rights Reserved 0/0
3SE03 North American Limit Switches
General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.
More information3SE03 North American Limit Switches
General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.
More informationApplications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings
Selection Guide Severe Duty Mill and Foundry Switches pplications Mill Mill Mill Mill Design 9007T Convertible sequence L0 Fixed sequence L14 Single Cable Pulls Fixed sequence L525 elt Conveyor Fixed sequence
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More informationSwitch Without Lever. Travel to Operate Contacts, Max N m (1.5 lb in) N m (4 lb in) 13
0T Lever Type Spring Return Plug-in Style Oiltight Switches Range of Operation Reset Reset Switch Without Lever Switch Without Lever and Base Product Selection Standard and Low Operating Torque Models
More informationClass 9038 Type A Mechanical Alternator, Open Tank
Selection Guide Float Switches Class 9038 Type A Mechanical Alternator, Open Tank Type of Installation Product Features Horsepower rated 4-pole switch Standard action contacts close on liquid rise Reverse
More informationAvailable as assembled switches or components. E50ANR1 with E50KL200 Lever. Conduit, cable and connector wiring options
Modular Plug-In Limit Switches E50 Series Available as assembled switches or components E50KL200 Easy to Install High Reliability Low Maintenance Modular to Reduced Inventory E50ANR1 with E50KL200 Lever.
More informationInstallation, Maintenance & Parts Manual
Installation, Maintenance & Parts Manual 2100 Series Center Drive Conveyors Table of Contents Warnings General Safety........................... 2 Introduction....................................... 2
More informationElectromechanical Level Control
Electromechanical Level Control Catalog 9034CT9701R2/08 08 Class 9036, 9037, and 9038 and Class 9049 Accessories CONTENTS Description..............................................Page Selection Guide..............................................
More informationInstallation, Maintenance & Parts Manual
Installation, Maintenance & Parts Manual 00 Series Center Drive Conveyors Table of Contents Warnings General Safety........................... Introduction....................................... Product
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS HEAVY DUTY LIMIT SWITCHES Types T and FT Robust, heavy duty switch 15 operating sequences available Most sequences are convertible in the field. Type T suitable
More informationEnvironment-Sealed Basic Switches
HoneywellSensing and Control 1-800-537-6945 USA 1-815-235-6847International 1-416-293-8111Canada 13 Environment-Sealed Basic Switches GENERAL INFORMATION SE and XE switches are the smallest environment-sealed
More informationTM ETRS-TM35FIN-ETRS89 WTG
Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,4 Meteorological coefficient, C0: 0,0 db Type of demand in calculation: 1: WTG noise is compared
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position Metal Push-Pull
More informationHeavy Duty, Industrial General Specifications XCKJ. Electrical Ratings Non-plug-in: A300 (AC), Q300 (DC)
Heavy Duty, Industrial General Specifications Rated Power Conforms to IEC 947-5-1, duty categories AC15 and DC13. emperature range -13 F to 158 F (-25 C to 7 ); optional -4 F (-4 C); +248 F (12 C). he
More information2200 Series Center Drive Conveyors
2200 Series Center Drive Conveyors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box 20 975 Cottonwood Ave. TEL: 1-800-397-8664 TEL: 262-367-7600 Hartland,
More informationREV: 000. Super Seca Flash Cure Units
REV: 000 Super Seca Flash Cure Units Table Of Contents Introduction 2 Standard Operating Guide 2 Features & Specs 2 External Layout 4-15 Internal Layout 16-24 Plug Guide 25 Wiring Diagrams 26-28 F.A.Q.
More informationches UL File No. E101598
Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the
More informationIndicator Lights (Neon, LED and Filament Lamp)
Indicator ights (Neon, ED and Filament amp) Colours and voltages: Neon Red, Amber, Green, Clear 100/130V (marked 110V), 200/250V (marked 230V) ED Red, Yellow, Green /2.2V Resistors for other voltages available
More informationLimit Switches and Safety
and Safety Introduction Overview 3SE5 23., 3SE5 21. 3SF1 2.4 3SE5 24., 3SF1 244 3SE5 13., 3SE5 11., 3SF1 114 3SE5 12., 3SF1 124 3SE5 16. 3SE5 232, 3SE5 212, 3SF1 2.4 3SE5 132, 3SE5 112, 3SF1 1.4 Position
More informationLocking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG
Locking Style Spring or Solenoid Locking Two locking mechanisms are available: spring lock with energized solenoid release and energized solenoid lock with spring release. Rigid and flexible in-line actuators
More informationSITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI
Application Dimensional drawings Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -60 to +550 C. Design Two support rings with replaceable orifice disk
More informationIndicator Lights Neon, LED and Filament Lamp
Indicator ights Neon, ED and Filament amp Colours and voltages: Neon Available with Red, Amber, Green or Clear lenses 100/130V (marked 110V), 200/250V (marked 230V) ED - Red, Yellow, Green, Blue, White
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationED SERIES SAFETY LIMIT SWITCH
Description The ED series safety limit switches conform to EN 547 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make
More information9012G Pressure and 9016G Vacuum Switches
Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:
More informationPower Distribution Blocks
Power Distribution Blocks One powerful way to manage your power distribution problems. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or
More informationXCS Safety Interlock Selection
Steven Engineering-2 Ryan Way-South San Francisco, CA 980-6370-Main Office:(650)588-9200-Outside Local Area:(800)258-9200-www.stevenengineering.com Selection Plastic, Double, Turret Head c, Type, locking
More informationCUSTOM ADD-ONS FOR ENGLISH UNITS
Spindles Flange Piloted Slot Collet Jacobs Taper Morse Taper See note on next page for location in the Specification Code No. Description A B C AA Flange 2.625 3.619/3.621 5.313 AB Piloted Slot 2.3125
More informationHigh Performance Thermal-Magnetic Circuit Breakers 410/520/
High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism
More informationSTRAIGHT BLADE PLUGS & CONNECTORS
STRAIGHT BLADE PLUGS & CONNECTORS Quick-thread assembly screws and cord-grip screws come backed-out, ready-to-wire. See-through, thermoplastic terminal chamber for clear view of terminals and wire connections.
More informationCylinder Position Sensors
TECHNOLOGY IN ACTION Stroke-to-GO LEVERLESS LIMIT SWITCH GO Switch Stroke-to-GO cylinder position sensors use three permanent magnets and push-pull plunger assembly to control a set of dry contacts. A
More informationSafety Limit Switch
Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit
More informationIEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101
IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With
More information1.134 L INEAR A CTUATOR: AIR C YLINDER S ERIES C95
1.134 L INEAR A CTUATOR: AIR C YLINDER H O W M ADE I N USA T ECHNICAL T O O R D E R C95 AIR C YLINDERS C95 P ISTON R OD S Basic K Non-Rotating P ISTON - Basic D Magnetic B ORE IN MM 50 63 80 100 B S T
More informationCommercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038
Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 TM Table of Contents Table of Contents SELECTION GUIDE PUMPTROL COMMERCIAL PRESSURE SWITCHES...
More informationInstallation, Maintenance & Parts Manual
Installation, Maintenance & Parts Manual 4100 Series End Drive Table of Contents Warnings General Safety........................ 2 Introduction.................................... 2 Product Description..............................
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More information2/3 Port Mechanical Valve. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)
2/3 Port Mechanical Valve Series 00 Large flow capacity. A variety of actuator types. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)
More informationInstallation, Maintenance & Parts Manual
Installation, Maintenance & Parts Manual 4100 Series End Drive Conveyors Table of Contents Warnings General Safety......................... 2 Introduction..................................... 2 Product
More informationCurrent Ratings All Limit Switch Types
urrent Ratings All Limit Switch s 9 ontact onfigurations Direct opening contacts to meet IE 947-- requirements for positive opening contacts, snap action, slow make-slow break, Reed contacts and other
More informationPush Button Units and Indicator Lights
3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,
More informationParts List, Wiring Diagrams
Parts List, Wiring Diagrams PAS180-300 SERIES PACKAGE GAS ELECTRIC UNITS TABLE OF CONTENTS PARTS LIST----------- 2-16 PARTS DRAWING - - - - - 17-28 WIRING DIAGRAMS - - - 29-52 Printed in U.S.A. 5/22/08
More informationNEW Cross Reference Tables See Pages 9-12
NEW Cross Reference Tables See Pages 9-12 Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com Wetguard Product
More informationThermal-Magnetic Circuit Breaker 201/-WA
Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring
More informationD4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications
Safety Limit Switch Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications H Snap-action contact for accurate switching with safe operation via direct drive positive
More informationSealed Pushbutton Switches
For application help: call 1-800-537-945. Honeywell MICO SWITCH Sensing and Control 113 meet high-performance needs for rugged, compact size sealed switches that are exposed to water, oil, cleaning solvents,
More informationSelector Push Button Cat. No. 800T-K2AAXX. a b c d e f g Right Left Right Left. d, e, f, g. Contact Blocks. No contacts on operator
NEMA Push Specifications 800T/H 30.5 mm Push s Selector Push Devices (Bul. 800T only) Selector Push Cat. No. 800T-K2AAXX 800T KD 2 G J D E a b c d e f g Right Left Right Left Blank C K KA KB KC KD KE a
More information4100 Series End Drive Conveyors
4100 Series End Drive Conveyors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box 20 975 Cottonwood Ave. TEL: 1-800-397-8664 TEL: 262-367-7600 Hartland,
More informationDuraGard Waterproof Connections
In this section... DuraGard Waterproof Connections DuraGard Overview...54 57 20 Amp...58 59 30 Amp...60 61 50 Amp...62 63 60 Amp...64 Accessories...65 66 Safety Interlocks...67 Dimensions...68 Engineering
More information30 AMP STANDARD SERVICE
4 Heavy Industrial/Marine Maxard Maxard Load-Breaking Plugs, 0 AMP STADARD SERVICE ** If receptacle is desired with a Straight Adapter instead of standard Angle Adapter, substitute S for the A in the catalog
More information3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.
8 SERIES /8 Ported Air Valves 1/ Ported Air Valves /8 & 1/ 1, 1A, 1B & 8 Series Note! Spring return & spring centered models NOT suitable for dry air service. Features & Way - Position. Way - &. operator
More informationMillennium TM. 100 thru 675 Tons (315 thru 2375 kw) renewal parts. Supersedes: RP1 (1099) Form RP1 (710) R-22 and R-134a 00202VIP
Millennium TM Rotary Screw Liquid Chillers renewal parts Supersedes: 160.80-RP1 (1099) Form 160.80-RP1 (710) Model YS BA CB S0 thru YS FA FB S5 (Style E) 100 thru 675 Tons (315 thru 2375 kw) 00202VIP R-22
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationDoor Interlock Switches
HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x x 46 mm) Four contacts Gold-plated contacts
More informationG3 UNIVERSAL GRIP CONFIGURATION GUIDE
G3 UNIVERSAL GRIP CONFIGURATION GUIDE www.ottoexcellence.com Industrial Grips for Demanding Applications OTTO serves agriculture, construction, off-highway, material handling and specialized industrial
More information1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information
1980 Rotating Cam Limit Switches Ordering Guide & Technical Information Features Precision Cam adjustment at any angular position of the Camshaft Speeds from 0 to 500 RPM in either direction No special
More informationMicrobore Hose, Assemblies & accessories
bar DN2 and DN4 High pressure Microbore hose Technical data Microbore hose The microbore hose assembly, most commonly used to connect to a Minimess test point for pressure testing, has many other diverse
More informationThe Product Range. Technical Data
The Product Range Section 3.1 - Basic Cylinder Bore sizes (mm): 10, 16, 25, 32, 40, 50 The basic cylinder series satisfies the support and guidance requirements of a great diversity of applications. Various
More informationPartner for Change : Appendix A
11/8/217 Partner for Change - 218: Appendix A Practice Greenhealth Awards Probo.CI CEC_HOSPITAL no.35321 Partner for Change - 218: Appendix A Introduction Completion of Appendix A mandatory. Please indicate
More informationLimit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark
Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty
More informationMAX-E1 FAMILY NEMA PREMIUM EFFICIENCY
MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp
More informationElectropneumatic Timing Relays Series 7000 Industrial
DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated
More informationALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight
ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards
More informationYS Series Contactors YS1N- F11 ****
YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable
More informationSELECTION LIST REVISION This book contains the following models: Chevy/GMC Dodge Ford
SELECTION LIST ---------- REVISION 0 ---------- This book contains the following models: 1973-2002 Chevy/GMC 1994-2002 Dodge 1980-2002 Ford Form #64135-120102 WESTERN PRODUCTS P.O. BOX 245038 MILWAUKEE,
More informationSet-up, Operation & Maintenance Manual
Set-up, Operation & Maintenance Manual 2100 Series Center Drive Conveyors Table of Contents Warnings General Safety.................... 2 Introduction................................ 2 Product Description..........................
More informationDistinctive Characteristics
Distinctive Characteristics Full face or spot illumination with incandescent lamps or multi-element LEDs, with or without resistors. Short Body Pushbuttons Series YB Choice of super bright LEDs in white,
More informationStearns Super-Mod Totally-Enclosed Non-Ventilated (TENV) Modules Featuring
TENV/IP54 Super-Mod Clutch-Brake Modules Imagine a totally-enclosed, nonventilated clutch-brake ready to work right out of the box, requiring no modifications. And at a price competitive with open enclosure
More information7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction
7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Note:7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data
More information1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information
1980 Rotating Cam imit Switches Ordering Guide & Technical Information Features Precision Cam adjustment at any angular position of the Camshaft Speeds from 0 to 500 RPM in either direction No special
More informationRussellstoll. Electrical Interconnection Systems. Computer System Plugs, Connectors and Receptacles. Quick Selection Chart. TüV
More than 30 years ago, Russellstoll offered the first pin and sleeve connectors that met the demanding needs of the Data Processing industry, and we ve been leading the way ever since. The expanding technology
More informationIDNM3581T 1HP,1745RPM,3PH,60HZ,143TC,0524M,TENV,F1
Product Information Packet IDNM3581T 1HP,1745RPM,3PH,60HZ,143TC,0524M,TENV,F1 Copyright All product information within this document is subject to Baldor Electric Company copyright protection, unless otherwise
More informationInformation. Model LEYG16 LEYG25 LEYG32
Information A rod type with guide newly added! Compatible with slide-bearing and ball-bushing bearing. Compatible with moment load and stopper (slide bearing). Speed control/positioning: ax. points Positioning
More informationKnob Lever Operator Cat. No. 800T-H17A 800 T HA 2 A. Protection Rating Description T Metal, Type 4/13 Plastic, Type 4/4X/13
2-Position Selector Switch Devices, Non-Illuminated Standard Knob perator Cat. No. 800T-H2 Knob Lever perator Cat. No. 800T-H17 Standard Knob perator Cat. No. 800H-HR2 800 T H 2 a b c d e a Protection
More informationJust the right switch for your application
Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationInstallation and Service Instructions for EX Series Explosion-proof Switches
Installation and Service Instructions for EX Series Explosion-proof Switches ISSUE 4 50009662 WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application
More informationLimit Switches. Heavy-Duty Plug-In Switches
1 Contents Modular Provide Extremely Easy Installation, High Reliability, and Low Maintenance and Inventory Costs Overview..................... 1 Model Selection, Assembled Switches.....................
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationLimit Switches Heavy-Duty Plug-In Switches
1 Contents Overview...................... 1 Model Selection, Assembled Switches..................... 2 Model Selection, Operating Heads.............. 5 Model Selection, Switch Bodies................. 6
More informationProduct Information Packet IDNM3587T 2HP,1755RPM,3PH,60HZ,145TC,0535M,TENV,F1
Product Information Packet IDNM3587T 2HP,1755RPM,3PH,60HZ,145TC,0535M,TENV,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationIssue/Rev. 0.3 (2/04) Bulletin P
Form No. P0906.03 E-Type Transmitter Parts List Issue/Rev. 0.3 (2/04) Bulletin P0906.03 (Previous Design) Switch and Network Assembly The Switch and Network Assembly is no longer available. To replace
More informationPosition switches FR series
Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket
More informationAreamaster LED Flood/High Bay Luminaires
Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust,
More informationHeavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return
CONTROLS Division of A-T Controls Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to,600,000 in. lbs. Double Acting and Spring Return THD S E R I E S The Triac line
More informationLimit Switches E47 Precision Switches
1 PG.0C.0.T.E July 0 E47 Precision The Cost-Effective Solution for Highly Accurate Switching Applications Contents Overview...................... 1 Model Selection, Basic Switches................ 2 Model
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationReferences 4 Fuse carriers
References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without
More informationProduct Information Packet CM HP,3450RPM,3PH,60HZ,56C,3410M,TEFC,F1
Product Information Packet CM3537.5HP,3450RPM,3PH,60HZ,56C,3410M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationDuraGard Waterproof Connections
In this section... DuraGard Waterproof Connections DuraGard Overview...54 57 20 Amp...58 59 30 Amp...60 61 50 Amp...62 63 60 Amp...64 Accessories...65 66 Safety Interlocks...67 Dimensions...68 Engineering
More informationProduct Information Packet CM HP,1725RPM,3PH,60HZ,56C,3416M,TEFC,F1
Product Information Packet CM3538-5.5HP,1725RPM,3PH,60HZ,56C,3416M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationSPARE CONNECTORS 2008
SPARE PARTS MANUAL ART.NO.: 3208201 ENGLISH INDEX SPARE CONNECTORS AA-AR SPARE CONNECTORS AS-BK SPARE CONNECTORS BL-BZ SPARE CONNECTORS CA-CP 1x 2x 3x 4x SPARE CONNECTORS CQ-DM SPARE CONNECTORS DN-EL
More informationsmissline Description
Modular power distribution bus system Description The power distribution bus system provides a versatile and flexible means of distributing power to a wide variety of electrical devices. Ideal for group
More informationSection 11. Specialty Control Devices. Control Catalog 11-1
Industrial Strongbox Solenoids (CR9500) Introduction...11-2 AC Solenoid Forms...11-3 Mounting Options and Accessories for AC Forms...11-3 DC Solenoid Forms...11-4 Outlines and Dimensions...11-4 Heavy Duty
More informationD4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information
Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding
More informationProduct Information Packet CM HP,1725RPM,3PH,60HZ,56C,3420M,TEFC,F1
Product Information Packet CM3542.75HP,1725RPM,3PH,60HZ,56C,3420M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationMICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series
MICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series DESCRIPTION When the application requires an industrial grade limit switch where wet, dust, or corrosive environments may be present,
More information