Areamaster LED Flood/High Bay Luminaires

Size: px
Start display at page:

Download "Areamaster LED Flood/High Bay Luminaires"

Transcription

1 Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust, water, dirt and rough usage are a problem Features Compact in size, attractively styled contemporary design, rugged and dependable. Easy to install and service. One-piece housing. One-piece lens hinged cover. Secured by four M6 captive stainless steel slotted hex-head bolts. Thermal shock and impact resistant glass lens. Heavy duty, high temperature silicone rubber gasket, mechanically secured. Universal design for flood and highbay mounting Mounting: Yoke mount, zinc plated steel yoke with architectural bronze polyester finish. High Bay Mounting: (1) Conduit entry on back of luminaire with locking set screw. Rotate yoke up or remove. Vibration rated in all configurations. Cool operating temperatures translate into long luminaire life. Total of three (3) 3/4" NPT entries with integral bushings. Standard Materials Ballast housing and lens door: aluminum Gasket: silicone rubber Reflector: polymaris metallized high reflectance finish Yoke mount: zinc plated steel Bolts: stainless steel Plugs: (2) aluminum provided Tempered glass lens Locking set screw: stainless steel Standard Finishes Housing, lens cover and yoke mount: architectural bronze polyester Certifications and Compliances NEC/CEC UL Standard: UL 1598, UL 1598A, UL 8750, UL 844 CSA Standards: C22.2 No , C22.2 No. 137 culus High Bay Lighting: Enclosed and Gasketed Visit our website at or contact us at (800) Lighting

2 T Numbers Lamp Supply Wire Temp. ( F/ C) Ambient Temp. ( F/ C) NEC/CEC Class I, Division 2, Groups A, B, C, D LED 140/60 104/40 T4 T Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations T Number T T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range ( ºF) Temp. Range ( C) Electrical Specifications Lighting Lighting: Enclosed and Gasketed Voltage Suffix Voltage Range Watts - Vac Input Power (Nom.) Input Amps (Max.) Power Factor BU > 0.90 BH > Visit our website at or contact us at (800)

3 Line Voltage For Class I, Division 2 Classified Duty and Marine Yoke Mount Catalog Number AMLED77YBU AMLED77YBH Accessories Description Catalog Numbers Crossarm Mounting Bracket Has 180 horizontal adjustment degree marked. Facilitates mounting floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed, architectural bronze polyester finish. G-AM-8-CA Pipe or Wall Mount Bracket Used with G-AM-8-CA. Clamps to 1 to 2-1/2 pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster finish. G-AM-8-WB Poletop Slip-Fitter Poletop Slip-Fitter Slip-fits 1-1/2 or 2 pipe size poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate sealed, with cast aluminum cap. Assembly has architectural bronze polyester finish. Slip-fits 2 or 2-1/2 poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyester finish. G-SF20 G-AM-8-SF Lighting: Enclosed and Gasketed Visit our website at or contact us at (800) Lighting

4 Dimensions in Inches/Millimeters in./388.6 mm 3.70 in./93.9 mm 7.20 in 2 / in./ mm mm 2 Conduit in./ Entry mm (Pendant Mount) Set 5.70 in./ Screw mm (4) Yoke Bolts 2.25 in./ 57.2 mm Conduit Entry Yoke 1.75 in./ mm (3) Mounting Holes 0.56 Dia in./88.9 mm 3.64 Turning Radius 180 Rotation 4.83 in./ mm 3.50 in./ 88.9 mm Ground Terminal (3) hubs for 3/4" NPT Conduit High Bay Pendant Mount Ceiling 12 in./ Recommended Minimum mm Mounting Distance Jct Box Set Screw Rotate Yoke Up or Remove Lighting Lighting: Enclosed and Gasketed Areamaster LED Weight Description Weight in Lbs/Kg Fixture Unit 22.00/ in./ mm 1158 Visit our website at or contact us at (800)

5 Luminaire Lumens = Mounting Height = ft, Tilt = 45 Maximum Calculated Value = 25 Fc Typical Footcandle Values fc.5 fc 20 fc 10 fc 1 fc 5 fc Luminaire Lumens = Mounting Height = ft, Tilt = 45 Maximum Calculated Value = 10 Fc Typical Footcandle Values 0 5 fc.5 fc 1 fc 10 fc footcandles (fc) footcandles (fc) Axial Candela Degree Horizontal Degree Vertical Lighting Lighting: Enclosed and Gasketed Area HID Visit our website at or contact us at (800)

6 High Bay CIE Type - General Diffuse Luminaire Lumens = Polar Graph - High Bay Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Rcc Rw Zonal Lumen Summary Zone Lumens % Fixture Lighting Lighting: Enclosed and Gasketed 1160 Visit our website at or contact us at (800)

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1, Groups E, F, G Class II Division 2, Groups F, G Class III Simultaneous Exposure Type 3R, 4, 4X IP66/67 Applications

More information

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent NEC/CEC: Type 3R, 4X IP66, IP67 Suitable for use in Wet Locations Marine Outside Type (Salt Water) Applications Powerful, efficient weatherproof lighting for applications such as: Security lighting Production

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations. Areamaster 100 Wide-Beam Floodlights NEC CEC V Class II, Divisions I and 2, Groups E, F, G V Class III Applications Highly efficient, all-weather flood-lighting for lower wattage service. Well suited for:

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Applications. Illustrated Features

Applications. Illustrated Features Applications For use in locations where a high degree of corrosion resistance is required. FR Series: For use in areas where high humidity or water vapor are present Typical uses include meat- or food-processing

More information

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,

More information

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps. Applications Enclosed and gasketed, non-metallic emergency lighting system suitable for use in areas where flammable gases or vapors may become present due to abnormal, unusual or accidental conditions

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures ATEX/IECEx: Zone 2 and 22 II 2 GD Lighting LIGHTING: ENCLOSED AND GASKETED AREA LED/INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial,

More information

Lighting: Explosionproof Area HID. Applications. Standard Materials

Lighting: Explosionproof Area HID. Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities

More information

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor Mercmaster III HID 50-250 Watt Luminaires Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing and other areas where

More information

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations Applications For use in hazardous locations defined by the NEC and CEC as Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Marine Outdoor Salt Water; UL1598A and. As well

More information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof Lighting Induction Code Master 2 Factory Sealed Induction Lighting System NEC/CEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens 1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide

More information

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC 1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC Part #: MHFL-1000W Made in the USA The powerful and efficient MHFL-1000W metal halide light fixture from Larson

More information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof Code Master 2 Factory Sealed Induction Lighting System Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) NEMA 4X

More information

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as

More information

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT MHD2/MHDO SERIES Marine Heavy Duty Outdoor Non-Metallic Fluorescent Non-metallic, glass reinforced polyester housing. 3/4 in. NPT aluminum hub. Captive stainless steel latches. Stainless steel mounting

More information

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations MHDS SERIES Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 198A Marine

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires NEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) Class I, Division

More information

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent MHD2/MHDO SERIES Marine Heavy Duty Non-Metallic Fluorescent Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844 Hazardous Locations

More information

N2MV Series W Non-metallic

N2MV Series W Non-metallic N2MV Series 50-175W Non-metallic Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Marine & Wet Locations, R, 4, 4X; IP56 L Applications: N2MV series Champ

More information

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit. Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,

More information

VINCI-LED Wall/Area/Flood Lighting

VINCI-LED Wall/Area/Flood Lighting Job Information Type: VINCI-LED Catalog #: Project: Comments: Prepared by: YEAR WARRANTY WARRANTY TEN INCLUDES LABOR ALLOWANCE Vinci Vinci Large 7⅞ ¼ ⅝ 9¾ ½ ⅛ Applications Wall/Surface Post/Bollard Low

More information

Fluorescent Lighting: Enclosed and Gasketed

Fluorescent Lighting: Enclosed and Gasketed luorescent Lighting: Enclosed and Gasketed 3-1 Page Description 2-5 V Series 2-3 eatures, Ordering Information and Accessories 4-5 Technical Data, Dimensions and Photometric Data 6-11 VRS and DRS luorescent

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

80 Watt Multi-Purpose LED Area Light

80 Watt Multi-Purpose LED Area Light JGMPAL Watt Multi-Purpose LED Area Light STANDARD Project: Type: Catalog #: WET kv Surge Protection IP65 The JGMPAL series is a group of architectural LED area luminaires designed to illuminate parking

More information

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

LEDMPAL15 15 Watt Multi-Purpose LED Area Light LEDMPAL15 15 Watt Multi-Purpose LED Area Light Project: Type: Catalog #: STANDARD FEATURES WET 1kV Surge Protection Available in 3000k (warm white), 4000K (neutral white) and 5000K (cool white). * Long-life

More information

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount 220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount Part #: HAL-PRM-250W-HPS-220V-PT Page: 1 Made in the USA The efficient HAL-PRM-250W-HPS-220V-PT high pressure sodium

More information

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations 1-24 Applications UL listed for marine type electric fixtures--outside type (salt water). Ideal in Class I, Div. 1 and 2 installations in refineries, pipeline transportation facilities; at drilling rigs

More information

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations SXPJ SERIES HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division 1, Groups E, F & G Class III Zone 1, Groups IIA & IIB Factory

More information

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit. UNILETS for Use with Threaded Metal Conduit. Applications Enclosed and gasketed HID lighting fixtures for use in tunnels, walkways, bridges, storage facilities, processing plants, parking lots, foundries,

More information

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations WFH LED SERIES W FH High-Bay Lighting for Hazardous & Wet Locations Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations

More information

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional. Haz HazMax Pinnacle/al APPLICATIONS Hazardous locations Watertight requirements Dusttight requirements Oil and gas exploration and production Waste water treatment plants Pipeline compressor / pumping

More information

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +

More information

LUFOHB IP65. Premium Round LED High Bay, 14,000 32,000 Lumens ( W) WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS DIMENSIONS

LUFOHB IP65. Premium Round LED High Bay, 14,000 32,000 Lumens ( W) WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS DIMENSIONS Catalog Number Project Type LUFOHB 14,000 32,000 ( 240W) STANDARD The LUFOHB is a premium round LED high bay luminaire It is designed to illuminate a wide variety of settings including commercial, industrial

More information

Standard Grade 14 Inch Reflector. Ordering Information

Standard Grade 14 Inch Reflector. Ordering Information Job Type Dimensions Specifications B A NRTL/C C Damp Location D E Slick- On Quick- On F A B C D E F 9-1/2" 2" 9-1/2" 20-22/32 24-27/32" 9-7/16" 14-1/4" 241 mm 51 mm 241 mm 536-631 mm 240 mm 362 mm 9-1/2"

More information

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof 1-1 Code Master 2 with Polyester Reflector Code Master Jr. without Reflector Code Master 2 Floodlight A-51 roup A & B with Porcelain Reflector

More information

F1-1. HID Lighting: Enclosed and Gasketed. Description. 2, 3 Mercmaster III Family Tree Mercmaster III HID Low Profile Lighting Fixtures

F1-1. HID Lighting: Enclosed and Gasketed. Description. 2, 3 Mercmaster III Family Tree Mercmaster III HID Low Profile Lighting Fixtures HID Lighting: Enclosed and Gasketed 1-1 Page Description 2, 3 Mercmaster III amily Tree 2-22 Mercmaster III HID Low Profile Lighting ixtures 23-54 Mercmaster III HID 50-250W Lighting ixtures Mercmaster

More information

Industrial Mercmaster LED Low Profile Luminaires For Ordinary Locations

Industrial Mercmaster LED Low Profile Luminaires For Ordinary Locations Type R, 4, 4X Marine Outside Type (Salt Water) For USA ONLY Applications Ordinary location fixtures suitable for use in: Heavy industrial locations where severe weather conditions, excessive moisture,

More information

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments WFHN LED SERIES High-Bay Lighting for Heavy Hose-Down Environments UL 1589 Wet Locations UL 8750 LED Safety NEMA 4X CUL Listed NSF Certified Food Equipment High Pressure Hose-Down One Piece Welded Aluminum

More information

WARRANTY & LISTINGS IP65 DIMENSIONS. Example: PLEDHBR-14-4K-PRM-BLK-UNV-OS + LEDHBRSN-PSH-PRM-V2 + MWAVEDHS-REM ORDERING INFORMATION.

WARRANTY & LISTINGS IP65 DIMENSIONS. Example: PLEDHBR-14-4K-PRM-BLK-UNV-OS + LEDHBRSN-PSH-PRM-V2 + MWAVEDHS-REM ORDERING INFORMATION. PLEDHBR-PRM Premium Round LED High Bay Shown with op onal occupancy sensor 14,000-3,000 (-40W) STANDARD WET 6-10kV Surge Protec on WARRANTY & LISTINGS IP65 culus listed for wet locations in ambient temperatures

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100 Code Master Jr. HID Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH. Medium Base. For Use with Threaded

More information

SXPJ SERIES S X azz.com/rigalite

SXPJ SERIES S X azz.com/rigalite SXPJ SERIES HID Lighting & Compact for Explosion Fluorescent Proof, Lighting Hazardous for and Hazardous Hostile Locations and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division

More information

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES L KILLARK TI IGH NG HA Z LO C LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES High temperature rated silicone gasketing provides Type 4X & IP66 sealing. Diffused Clear 2 Lens Choices: Clear for

More information

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description: Project Number Date 15.00487 3/26/2015 LAB 6 Test Sample Description Catalog Number: Description: P3408-0930K9 Close to Ceiling fixture Test Method: Preburn Time: Time To Stabilize: Total Operating Time:

More information

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations PREDATOR The Predator floodlight offers versatility, efficiency, and performance, which provides a unique solution to a variety of lighting needs. With the Predator, Holophane continues its legacy of utilizing

More information

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations RSS SERIES Fluorescent Lighting for Hazardous Locations R S S Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Location UL 1598A Marine Outside Type CUL Wet Locations IP66 55 Ambient Temperature

More information

ORDERING INFORMATION: 120 Volts (120)

ORDERING INFORMATION: 120 Volts (120) Bull38 A weather tight unit fabricated from durable grade die-cast aluminum & fully sealed, gasketed glass lens. Mount: 1/2 threaded adjustable knuckle mount Porcelain medium base socket Thermoset polyester

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] 3672 [ECN] 3734 [TESTLAB] Tempo LLC [ISSUEDATE] 1/11/2019 9:30:38 AM [MANUFAC] Tempo LLC [LUMCAT] C6R-5030-00-UNVE5-35-LG [LUMINAIRE]

More information

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and

More information

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch

More information

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22 Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against

More information

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous

More information

MAR SERIES Fluorescent Lighting for Hazardous Locations

MAR SERIES Fluorescent Lighting for Hazardous Locations MAR SERIES M AR Fluorescent Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C, & D Seismic Tested UL 844 Hazardous Locations UL 924 Emergency Lighting UL 1598A Marine Outside Type CSA

More information

DESCRIPTION & APPLICATION

DESCRIPTION & APPLICATION T5 FME T5 4L - Full Body High Bay DESCRIPTION & APPLICATION The Envirobrite FME T5 fixture is a full body fluorescent high bay ideal for replacing energy devouring HID fixtures. This all aluminum enclosed

More information

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors Application Provide a liquidtight and strain relief termination for flexible type neoprene, hypalon, and PVC jacketed power or control cord and cable. For use in wet or dry locations sealing electrical

More information

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire SAFR LED SERIES Hazardous Location LED Luminaire Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844

More information

PAGE 1/9. Lumileds Luxeon CoB 1205, delivers a lumen maintenance greater than 70% after 50,000 hours of operation (L 70

PAGE 1/9. Lumileds Luxeon CoB 1205, delivers a lumen maintenance greater than 70% after 50,000 hours of operation (L 70 Assembled Insulated Ceiling Housing PAGE 1/9 Project Notes Fixture Type Date DESCRIPTION Assembled Modul-Aim units for new construction in insulated ceilings, Offered in 1 or head configurations. SPECIFICATIONS

More information

MagnaPro Hazardous Area Drop Lens Fluorescent

MagnaPro Hazardous Area Drop Lens Fluorescent CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 2 - Groups F & G CSA - Type 3 UL 844 - Class I Div. 2 - Groups A, B, C, & D UL - Outdoor Marine

More information

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22 FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4

More information

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) 4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are

More information

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA FCW3043 2.5 in FCW3045 2.3 in FCW3042 2.3 in FCW3040 2.2 in 120 www.fclighting.com *Consult website for updated specification sheets regarding detailed information and performance. FC Lighting, Inc. 2012.

More information

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION SURFE/CEILING & SUSPENDED MOUNT INSTALLATION E477827 E477827 APPLICATION NL luminaires are designed for use indoors, outdoors, wet locations, areas containing moisture, dirt, corrosion, vibration and rough

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] G0175 [TESTLAB] TBR TORONTO [ISSUEDATE] 04-23-2015 [MANUFAC] MERCURY LIGHITNG [MORE]FAIRFIELD, NEW JERSEY [LUMCAT] LHB5-4-32000-40K-U80-UNI

More information

Haz. HazMax Intrepid/nm TECHNICAL SPECIFICATIONS

Haz. HazMax Intrepid/nm TECHNICAL SPECIFICATIONS Haz HazMax Intrepid/nm APPLICATIONS Hazardous locations Marine and watertight requirements Dusttight requirements Oil and gas exploration and production Petrochemical facilities APPROVALS Class I Division

More information

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot CATALOG NO. TYPE NO. JOB NAME -8 GP Flood Series Floodlighting GP (Mini) ORDERING INFORMATION Catalog Number: Example: GPA070TEL GP A TE SERIES GP-General Purpose Flood SIZE -Mini ACCESSORIES GPGS = Visor

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full

More information

DuraPro Hazardous Area Fluorescent

DuraPro Hazardous Area Fluorescent CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 2 - Groups F & G CSA - Type 3 UL 844 - Class I Div. 2 - Groups A, B, C, & D UL - Outdoor Marine

More information

003 3 foot foot RUN Nominal Length* * For actual lengths see

003 3 foot foot RUN Nominal Length* * For actual lengths see M125 Project: Type: Qty: Series Lamping Shielding Mounting Nominal Length Finish Voltage Options Series Lamping Shielding Mounting Nominal Length Finish Voltage Options M125 (M125/9 Direct) Multi-Mount

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design - 3 or 4 Lamp Curved Profile Design Description HFB3 series high-bay fluorescent fixture is a great energy saving alternative to traditional HID highbay fixtures. This fixture operates three or four lamps

More information

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1 Job Type Dimensions Specifications B A C NRTL/C Damp Location D Slick-On Quick-On E A B C D E 9-1/2" 2" 9-1/2" 26-11/16" 23-1/8" 241 mm 51 mm 241 mm 678 mm 587 mm 9-1/2" 1-1/8" 8-5/8" 25-13/16" 23-1/8"

More information

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,

More information

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

S BERGIN R BEATTIE Lighting Engineer. Checked Approved REPORT NUMBER: ITL73351 PAGE: 1 OF 10 CATALOG NUMBER: MARRAKESH SCONCE I (LED) LUMINAIRE: FABRICATED BRONZE COLORED METAL UPPER HOUSING AND OPTICAL COMPARTMENT, 1 LED MODULE, FABRICATED BRONZE COLORED

More information

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions ! CAUTION All wiring should be done by a licensed electrician in accordance with state codes, local codes and National Electric Code (NEC) standards. Improper installation may result in serious injury

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications

More information

LEN Series 2x2 / 2x4 LED

LEN Series 2x2 / 2x4 LED FEATURES & SPECIFICATIONS Intended Use The LEN offers the look and feel of a fluorescent luminaire - subtle soft direct elements, interest and depth across the ceiling plane - with a contemporary look

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] [TESTLAB] Deliver Co., Ltd. [TESTDATE] 2018-03-10 [ISSUEDATE] 2018-03-11 15:27:40 [NEARFIELD] [LAMPPOSITION] 0,0 [OTHER] [MANUFAC]

More information

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview DL2000 High Brightness 6 LED Downlight Module Overview Heatron s Innovation Series DL2000 recessed downlight module helps luminaire manufacturers expand their product lines and bring new LED fixtures to

More information

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor Heavy industrial LED lighting Champ Pro PFM LED luminaires Champ PFM LED floodlights for heavy industrial areas Authorized Distributor Champ Pro PFM LED floodlights Safe. Reliable. Efficient. Featuring

More information

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations LED Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844 Hazardous Locations UL 598 Wet Locations UL

More information

Spring-loaded cover seats against neoprene gasket.

Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs

More information

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation. Catalog Number: Type: Project: Comments: Date: LED Flood Series FL1 Knuckle Mount The LED Flood Series is a family of energy efficient solutions for replacing high wattage outdoor flood luminaires. Their

More information

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS H6..H Project: Fixture Type: Location: Contact/Phone: FINIA LED WALL MOUNTED HAZARDOUS LOCATION CLASSIFIED AREAS LW AND LW SERIES DOWN OR UP OPTICS LED W, W, AND 8W PRODUCT DESCRIPTION The Finia LED LW

More information

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC Date: Customer: Project: Type: Qty: Saturn Cutoff Order Code: SAC - - - - - - - - SAC Series SAC Saturn Cutoff Pole Order Code: - - - Series Height Finish Options Optics R Type II Distribution R Type V

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000535-001 [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,

More information

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors

More information

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE: INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 1 OF 7 CATALOG NUMBER: RP-LUM-48-3500-WHT LUMINAIRE: FABRICATED WHITE PAINTED METAL TOP HOUSING/REFLECTOR, 12 WHITE CIRCUIT

More information

Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect

Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect DROP LENS See p.2 for DLC Approved Products CAT #: PREP BY: DATE: PROJECT: TYPE: NOTES: 135 [5.3] 19 [0.75] 91 [3.6] 95 [3.7] Meta Blanc Meta

More information

Highbay Fluorescent - Six Lamp Flat Profile Design

Highbay Fluorescent - Six Lamp Flat Profile Design - Six Lamp Flat Profile Design Description HFA series high-bay fluorescent fixture is a great energy saving alternative to traditional HID highbay fixtures. This fixture operates six lamps and as a standard

More information

Capella 3. Project Name. Construction. Optical System. Product Applications

Capella 3. Project Name. Construction. Optical System. Product Applications Product # Type Date Project Name Project Location Capella 3 Construction Housing and lens frame are constructed from heavy-duty low copper die-cast aluminum. Material is structurally rigid and uniformly

More information

ENDURALUME HL /02

ENDURALUME HL /02 ENDURALUME The Enduralume luminaire is an efficient, low brightness unit for lighting both industrial and commercial areas. Whether it be schools, food processing areas or warehouses, this is a great luminaire

More information

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) - Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) - Part #: HALP-EMG-24-2L-BX Made in the USA The Larson Electronics HALP-EMG-24-2L-BX Hazardous Area Fluorescent

More information

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA LED LINEAR CORTANA This simple and elegant suspended LED linear light with wide optics is ideal for general uniform ambient lighting applications where clean, modern architectural design is required. Use

More information